USE_OPLINE
zend_free_op free_op1;
+ zval *op1, *op2;
+ int result;
SAVE_OPLINE();
- is_identical_function(&EX_T(opline->result.var).tmp_var,
- _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
- zval_ptr_dtor_nogc(&free_op1.var);
+ op1 = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
+ op2 = EX_CONSTANT(opline->op2);
+ result = fast_is_not_identical_function(op1, op2);
+ zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ ZEND_VM_SMART_BRANCH(result, 1);
+ ZVAL_BOOL(EX_VAR(opline->result.var), result);
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_IS_NOT_IDENTICAL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(binary_op_type binary_op ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *result = &EX_T(opline->result.var).tmp_var;
+ zend_free_op free_op1, free_op_data1;
+ zval *object;
+ zval *property;
+ zval *value;
+ zval *zptr;
SAVE_OPLINE();
- is_identical_function(result,
- _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
- Z_LVAL_P(result) = !Z_LVAL_P(result);
- zval_ptr_dtor_nogc(&free_op1.var);
+ object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ if (IS_VAR == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
-static int ZEND_FASTCALL ZEND_IS_EQUAL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *result = &EX_T(opline->result.var).tmp_var;
+ HANDLE_EXCEPTION();
+ }
- SAVE_OPLINE();
- ZVAL_BOOL(result, fast_equal_function(result,
- _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC),
- opline->op2.zv TSRMLS_CC));
- zval_ptr_dtor_nogc(&free_op1.var);
+ property = EX_CONSTANT(opline->op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot use string offset as an object");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
-static int ZEND_FASTCALL ZEND_IS_NOT_EQUAL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *result = &EX_T(opline->result.var).tmp_var;
+ HANDLE_EXCEPTION();
+ }
- SAVE_OPLINE();
- ZVAL_BOOL(result, fast_not_equal_function(result,
- _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC),
- opline->op2.zv TSRMLS_CC));
- zval_ptr_dtor_nogc(&free_op1.var);
+ do {
+ value = get_zval_ptr_r((opline+1)->op1_type, (opline+1)->op1, execute_data, &free_op_data1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to assign property of non-object");
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ break;
+ }
+ }
-static int ZEND_FASTCALL ZEND_IS_SMALLER_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *result = &EX_T(opline->result.var).tmp_var;
+ /* here we are sure we are dealing with an object */
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
++ }
++ } else {
++ ZVAL_DEREF(zptr);
++ SEPARATE_ZVAL_NOREF(zptr);
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
-
- binary_op(zptr, zptr, value);
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), zptr);
- SAVE_OPLINE();
- ZVAL_BOOL(result, fast_is_smaller_function(result,
- _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC),
- opline->op2.zv TSRMLS_CC));
- zval_ptr_dtor_nogc(&free_op1.var);
++ binary_op(zptr, zptr, value);
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_COPY(EX_VAR(opline->result.var), zptr);
++ }
+ }
+ } else {
+ zend_assign_op_overloaded_property(object, property, ((IS_CONST == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), value, binary_op, (UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL));
+ }
+ } while (0);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ FREE_OP(free_op_data1);
+
+ if (UNEXPECTED(free_op1)) {zval_ptr_dtor_nogc(free_op1);};
+ /* assign_obj has two opcodes! */
+ ZEND_VM_NEXT_OPCODE_EX(1, 2);
}
-static int ZEND_FASTCALL ZEND_IS_SMALLER_OR_EQUAL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(binary_op_type binary_op ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *result = &EX_T(opline->result.var).tmp_var;
+ zend_free_op free_op1, free_op_data1;
+ zval *var_ptr, rv;
+ zval *value, *container, *dim;
SAVE_OPLINE();
- ZVAL_BOOL(result, fast_is_smaller_or_equal_function(result,
- _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC),
- opline->op2.zv TSRMLS_CC));
- zval_ptr_dtor_nogc(&free_op1.var);
+ container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+ if (IS_VAR == IS_UNUSED && UNEXPECTED(Z_OBJ_P(container) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ HANDLE_EXCEPTION();
+ }
+ if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_throw_error(NULL, "Cannot use string offset as an array");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
-static int ZEND_FASTCALL ZEND_BW_OR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
+ HANDLE_EXCEPTION();
+ }
- SAVE_OPLINE();
- bitwise_or_function(&EX_T(opline->result.var).tmp_var,
- _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
- zval_ptr_dtor_nogc(&free_op1.var);
+ dim = EX_CONSTANT(opline->op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ do {
+ if (IS_VAR == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) != IS_ARRAY)) {
+ if (IS_VAR != IS_UNUSED) {
+ ZVAL_DEREF(container);
+ }
+ if (IS_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ value = get_zval_ptr_r((opline+1)->op1_type, (opline+1)->op1, execute_data, &free_op_data1);
+ zend_binary_assign_op_obj_dim(container, dim, value, UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL, binary_op);
+ break;
+ }
+ }
-static int ZEND_FASTCALL ZEND_BW_AND_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
+ zend_fetch_dimension_address_RW(&rv, container, dim, IS_CONST);
+ value = get_zval_ptr_r((opline+1)->op1_type, (opline+1)->op1, execute_data, &free_op_data1);
+ ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+ var_ptr = Z_INDIRECT(rv);
- SAVE_OPLINE();
- bitwise_and_function(&EX_T(opline->result.var).tmp_var,
- _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
- zval_ptr_dtor_nogc(&free_op1.var);
+ if (UNEXPECTED(var_ptr == NULL)) {
+ zend_throw_error(NULL, "Cannot use assign-op operators with overloaded objects nor string offsets");
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ FREE_OP(free_op_data1);
+ if (UNEXPECTED(free_op1)) {zval_ptr_dtor_nogc(free_op1);};
+ HANDLE_EXCEPTION();
+ }
-static int ZEND_FASTCALL ZEND_BW_XOR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
+ if (UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
- SAVE_OPLINE();
- bitwise_xor_function(&EX_T(opline->result.var).tmp_var,
- _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
- zval_ptr_dtor_nogc(&free_op1.var);
+ binary_op(var_ptr, var_ptr, value);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+ }
+ }
+ } while (0);
+
+ FREE_OP(free_op_data1);
+ if (UNEXPECTED(free_op1)) {zval_ptr_dtor_nogc(free_op1);};
+ ZEND_VM_NEXT_OPCODE_EX(1, 2);
}
-static int ZEND_FASTCALL ZEND_BOOL_XOR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_CONST(binary_op_type binary_op ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
zend_free_op free_op1;
{
USE_OPLINE
zend_free_op free_op1;
- zval **object_ptr;
zval *object;
zval *property;
- zval **retval;
- int have_get_ptr = 0;
+ zval *zptr;
SAVE_OPLINE();
- object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
- property = opline->op2.zv;
- retval = &EX_T(opline->result.var).var.ptr;
-
- if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
-
- make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
- object = *object_ptr;
+ object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ if (IS_VAR == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- *retval = &EG(uninitialized_zval);
- }
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ HANDLE_EXCEPTION();
}
- /* here we are sure we are dealing with an object */
+ property = EX_CONSTANT(opline->op2);
- if (0) {
- MAKE_REAL_ZVAL_PTR(property);
- }
+ if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot increment/decrement overloaded objects nor string offsets");
- if (Z_OBJ_HT_P(object)->get_property_ptr_ptr) {
- zval **zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- if (zptr != NULL) { /* NULL means no success in getting PTR */
- have_get_ptr = 1;
- if (UNEXPECTED(*zptr == &EG(error_zval))) {
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- *retval = &EG(uninitialized_zval);
- }
- } else {
- SEPARATE_ZVAL_IF_NOT_REF(zptr);
+ HANDLE_EXCEPTION();
+ }
- incdec_op(*zptr);
- if (RETURN_VALUE_USED(opline)) {
- *retval = *zptr;
- PZVAL_LOCK(*retval);
+ do {
+ if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
}
+ break;
}
}
- }
-
- if (!have_get_ptr) {
- if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval *z;
- Z_ADDREF_P(object);
- z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
-
- if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
- zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
+ /* here we are sure we are dealing with an object */
-
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
-
- if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
- if (inc) {
- fast_long_increment_function(zptr);
- } else {
- fast_long_decrement_function(zptr);
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
-
- if (inc) {
- increment_function(zptr);
++ if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
++ if (inc) {
++ fast_long_increment_function(zptr);
++ } else {
++ fast_long_decrement_function(zptr);
++ }
+ } else {
- decrement_function(zptr);
++ ZVAL_DEREF(zptr);
++ SEPARATE_ZVAL_NOREF(zptr);
+
- if (Z_REFCOUNT_P(z) == 0) {
- GC_REMOVE_ZVAL_FROM_BUFFER(z);
- zval_dtor(z);
- FREE_ZVAL(z);
++ if (inc) {
++ increment_function(zptr);
++ } else {
++ decrement_function(zptr);
++ }
++ }
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_COPY(EX_VAR(opline->result.var), zptr);
}
- }
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), zptr);
- z = value;
}
- Z_ADDREF_P(z);
- SEPARATE_ZVAL_IF_NOT_REF(&z);
- incdec_op(z);
- *retval = z;
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- zval_ptr_dtor(&object);
- SELECTIVE_PZVAL_LOCK(*retval, opline);
- zval_ptr_dtor(&z);
} else {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- *retval = &EG(uninitialized_zval);
- }
+ zend_pre_incdec_overloaded_property(object, property, ((IS_CONST == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), inc, (UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL));
}
- }
-
- if (0) {
- zval_ptr_dtor(&property);
- } else {
+ } while (0);
- }
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (UNEXPECTED(free_op1)) {zval_ptr_dtor_nogc(free_op1);};
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_pre_incdec_property_helper_SPEC_VAR_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_TAIL_CALL(zend_pre_incdec_property_helper_SPEC_VAR_CONST(1 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_pre_incdec_property_helper_SPEC_VAR_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_TAIL_CALL(zend_pre_incdec_property_helper_SPEC_VAR_CONST(0 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_CONST(int inc ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
zend_free_op free_op1;
- zval **object_ptr;
zval *object;
zval *property;
- zval *retval;
- int have_get_ptr = 0;
+ zval *zptr;
SAVE_OPLINE();
- object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
- property = opline->op2.zv;
- retval = &EX_T(opline->result.var).tmp_var;
-
- if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
-
- make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
- object = *object_ptr;
-
- if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-
- ZVAL_NULL(retval);
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
+ object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- /* here we are sure we are dealing with an object */
+ if (IS_VAR == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
- if (0) {
- MAKE_REAL_ZVAL_PTR(property);
+ HANDLE_EXCEPTION();
}
- if (Z_OBJ_HT_P(object)->get_property_ptr_ptr) {
- zval **zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- if (zptr != NULL) { /* NULL means no success in getting PTR */
- have_get_ptr = 1;
- if (UNEXPECTED(*zptr == &EG(error_zval))) {
- ZVAL_NULL(retval);
- } else {
- SEPARATE_ZVAL_IF_NOT_REF(zptr);
+ property = EX_CONSTANT(opline->op2);
- ZVAL_COPY_VALUE(retval, *zptr);
- zendi_zval_copy_ctor(*retval);
+ if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot increment/decrement overloaded objects nor string offsets");
- incdec_op(*zptr);
- }
- }
+ HANDLE_EXCEPTION();
}
- if (!have_get_ptr) {
- if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval *z, *z_copy;
-
- Z_ADDREF_P(object);
- z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
- zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
-
- if (Z_REFCOUNT_P(z) == 0) {
- GC_REMOVE_ZVAL_FROM_BUFFER(z);
- zval_dtor(z);
- FREE_ZVAL(z);
- }
- z = value;
+ do {
+ if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ break;
}
- ZVAL_COPY_VALUE(retval, z);
- zendi_zval_copy_ctor(*retval);
- ALLOC_ZVAL(z_copy);
- INIT_PZVAL_COPY(z_copy, z);
- zendi_zval_copy_ctor(*z_copy);
- incdec_op(z_copy);
- Z_ADDREF_P(z);
- Z_OBJ_HT_P(object)->write_property(object, property, z_copy, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- zval_ptr_dtor(&object);
- zval_ptr_dtor(&z_copy);
- zval_ptr_dtor(&z);
- } else {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- ZVAL_NULL(retval);
}
- }
-
- if (0) {
- zval_ptr_dtor(&property);
- } else {
-
- }
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_post_incdec_property_helper_SPEC_VAR_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_post_incdec_property_helper_SPEC_VAR_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_VAR_CONST(int type, ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *varname;
- zval **retval;
- zval tmp_varname;
- HashTable *target_symbol_table;
- ulong hash_value;
- SAVE_OPLINE();
- varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
-
- if (IS_VAR != IS_CONST && UNEXPECTED(Z_TYPE_P(varname) != IS_STRING)) {
- ZVAL_COPY_VALUE(&tmp_varname, varname);
- zval_copy_ctor(&tmp_varname);
- Z_SET_REFCOUNT(tmp_varname, 1);
- Z_UNSET_ISREF(tmp_varname);
- convert_to_string(&tmp_varname);
- varname = &tmp_varname;
- }
-
- if (IS_CONST != IS_UNUSED) {
- zend_class_entry *ce;
+ /* here we are sure we are dealing with an object */
- if (IS_CONST == IS_CONST) {
- if (CACHED_PTR(opline->op2.literal->cache_slot)) {
- ce = CACHED_PTR(opline->op2.literal->cache_slot);
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
-
- if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
- if (inc) {
- fast_long_increment_function(zptr);
- } else {
- fast_long_decrement_function(zptr);
- }
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
} else {
- ZVAL_DEREF(zptr);
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
- zval_opt_copy_ctor(zptr);
- if (inc) {
- increment_function(zptr);
- ce = zend_fetch_class_by_name(Z_STRVAL_P(opline->op2.zv), Z_STRLEN_P(opline->op2.zv), opline->op2.literal + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- if (IS_VAR != IS_CONST && varname == &tmp_varname) {
- zval_dtor(&tmp_varname);
++ if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
++ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
++ if (inc) {
++ fast_long_increment_function(zptr);
++ } else {
++ fast_long_decrement_function(zptr);
++ }
+ } else {
- decrement_function(zptr);
++ ZVAL_DEREF(zptr);
++ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
++ zval_opt_copy_ctor(zptr);
++ if (inc) {
++ increment_function(zptr);
++ } else {
++ decrement_function(zptr);
+ }
- zval_ptr_dtor_nogc(&free_op1.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
}
- CACHE_PTR(opline->op2.literal->cache_slot, ce);
}
} else {
- ce = EX_T(opline->op2.var).class_entry;
- }
- retval = zend_std_get_static_property(ce, Z_STRVAL_P(varname), Z_STRLEN_P(varname), 0, ((IS_VAR == IS_CONST) ? opline->op1.literal : NULL) TSRMLS_CC);
- zval_ptr_dtor_nogc(&free_op1.var);
- } else {
- target_symbol_table = zend_get_target_symbol_table(opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-/*
- if (!target_symbol_table) {
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-*/
- if (IS_VAR == IS_CONST) {
- hash_value = Z_HASH_P(varname);
- } else {
- hash_value = str_hash(Z_STRVAL_P(varname), Z_STRLEN_P(varname));
- }
-
- if (zend_hash_quick_find(target_symbol_table, Z_STRVAL_P(varname), Z_STRLEN_P(varname)+1, hash_value, (void **) &retval) == FAILURE) {
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_UNSET:
- zend_error(E_NOTICE,"Undefined variable: %s", Z_STRVAL_P(varname));
- /* break missing intentionally */
- case BP_VAR_IS:
- retval = &EG(uninitialized_zval_ptr);
- break;
- case BP_VAR_RW:
- zend_error(E_NOTICE,"Undefined variable: %s", Z_STRVAL_P(varname));
- /* break missing intentionally */
- case BP_VAR_W:
- Z_ADDREF_P(&EG(uninitialized_zval));
- zend_hash_quick_update(target_symbol_table, Z_STRVAL_P(varname), Z_STRLEN_P(varname)+1, hash_value, &EG(uninitialized_zval_ptr), sizeof(zval *), (void **) &retval);
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
- }
- }
- switch (opline->extended_value & ZEND_FETCH_TYPE_MASK) {
- case ZEND_FETCH_GLOBAL:
- if (IS_VAR != IS_TMP_VAR) {
- zval_ptr_dtor_nogc(&free_op1.var);
- }
- break;
- case ZEND_FETCH_LOCAL:
- zval_ptr_dtor_nogc(&free_op1.var);
- break;
- case ZEND_FETCH_STATIC:
- zval_update_constant(retval, 1 TSRMLS_CC);
- break;
- case ZEND_FETCH_GLOBAL_LOCK:
- if (IS_VAR == IS_VAR && !free_op1.var) {
- PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
- }
- break;
- }
- }
-
-
- if (IS_VAR != IS_CONST && varname == &tmp_varname) {
- zval_dtor(&tmp_varname);
- }
- if (opline->extended_value & ZEND_FETCH_MAKE_REF) {
- SEPARATE_ZVAL_TO_MAKE_IS_REF(retval);
- }
- PZVAL_LOCK(*retval);
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_IS:
- EX_T(opline->result.var).var.ptr = *retval;
- break;
- case BP_VAR_UNSET: {
- zend_free_op free_res;
-
- PZVAL_UNLOCK(*retval, &free_res);
- if (retval != &EG(uninitialized_zval_ptr)) {
- SEPARATE_ZVAL_IF_NOT_REF(retval);
- }
- PZVAL_LOCK(*retval);
- FREE_OP_VAR_PTR(free_res);
+ zend_post_incdec_overloaded_property(object, property, ((IS_CONST == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), inc, EX_VAR(opline->result.var));
}
- /* break missing intentionally */
- default:
- EX_T(opline->result.var).var.ptr_ptr = retval;
- break;
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_R_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_VAR_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_W_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_VAR_CONST(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_RW_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_VAR_CONST(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_FUNC_ARG_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ } while (0);
- return zend_fetch_var_address_helper_SPEC_VAR_CONST(zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC) ? BP_VAR_W : BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ if (UNEXPECTED(free_op1)) {zval_ptr_dtor_nogc(free_op1);};
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_FETCH_UNSET_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_fetch_var_address_helper_SPEC_VAR_CONST(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_TAIL_CALL(zend_post_incdec_property_helper_SPEC_VAR_CONST(1 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL ZEND_FETCH_IS_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_fetch_var_address_helper_SPEC_VAR_CONST(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_TAIL_CALL(zend_post_incdec_property_helper_SPEC_VAR_CONST(0 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_FETCH_DIM_W_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
}
/* here we are sure we are dealing with an object */
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
-
- PZVAL_LOCK(retval);
- EX_T(opline->result.var).var.ptr = retval;
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CV == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
++ }
++ } else {
++ ZVAL_DEREF(zptr);
++ SEPARATE_ZVAL_NOREF(zptr);
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
-
- binary_op(zptr, zptr, value);
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), zptr);
- if (1) {
- zval_ptr_dtor(&offset);
++ binary_op(zptr, zptr, value);
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_COPY(EX_VAR(opline->result.var), zptr);
++ }
+ }
} else {
- zval_dtor(free_op2.var);
+ zend_assign_op_overloaded_property(object, property, ((IS_CV == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), value, binary_op, (UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL));
}
- }
+ } while (0);
- zval_ptr_dtor_nogc(&free_op1.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ FREE_OP(free_op_data1);
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_property_address_read_helper_SPEC_VAR_TMP(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ if (UNEXPECTED(free_op1)) {zval_ptr_dtor_nogc(free_op1);};
+ /* assign_obj has two opcodes! */
+ ZEND_VM_NEXT_OPCODE_EX(1, 2);
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_W_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_VAR_CV(binary_op_type binary_op ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *property;
- zval **container;
+ zend_free_op free_op1, free_op_data1;
+ zval *var_ptr, rv;
+ zval *value, *container, *dim;
SAVE_OPLINE();
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC);
+ container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+ if (IS_VAR == IS_UNUSED && UNEXPECTED(Z_OBJ_P(container) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
- if (1) {
- MAKE_REAL_ZVAL_PTR(property);
+ HANDLE_EXCEPTION();
}
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
+ zend_throw_error(NULL, "Cannot use string offset as an array");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
- zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
- if (1) {
- zval_ptr_dtor(&property);
- } else {
- zval_dtor(free_op2.var);
- }
- if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
- EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
+ HANDLE_EXCEPTION();
}
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- /* We are going to assign the result by reference */
- if (opline->extended_value & ZEND_FETCH_MAKE_REF) {
- zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+ dim = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var);
- Z_DELREF_PP(retval_ptr);
- SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
- Z_ADDREF_PP(retval_ptr);
- EX_T(opline->result.var).var.ptr = *EX_T(opline->result.var).var.ptr_ptr;
- EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
- }
+ do {
+ if (IS_VAR == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) != IS_ARRAY)) {
+ if (IS_VAR != IS_UNUSED) {
+ ZVAL_DEREF(container);
+ }
+ if (IS_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ value = get_zval_ptr_r((opline+1)->op1_type, (opline+1)->op1, execute_data, &free_op_data1);
+ zend_binary_assign_op_obj_dim(container, dim, value, UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL, binary_op);
+ break;
+ }
+ }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ zend_fetch_dimension_address_RW(&rv, container, dim, IS_CV);
+ value = get_zval_ptr_r((opline+1)->op1_type, (opline+1)->op1, execute_data, &free_op_data1);
+ ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+ var_ptr = Z_INDIRECT(rv);
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_RW_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *property;
- zval **container;
+ if (UNEXPECTED(var_ptr == NULL)) {
+ zend_throw_error(NULL, "Cannot use assign-op operators with overloaded objects nor string offsets");
- SAVE_OPLINE();
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC);
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
+ FREE_OP(free_op_data1);
+ if (UNEXPECTED(free_op1)) {zval_ptr_dtor_nogc(free_op1);};
+ HANDLE_EXCEPTION();
+ }
- if (1) {
- MAKE_REAL_ZVAL_PTR(property);
- }
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
- zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_RW TSRMLS_CC);
- if (1) {
- zval_ptr_dtor(&property);
- } else {
- zval_dtor(free_op2.var);
- }
- if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
- EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
- }
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
+
+ binary_op(var_ptr, var_ptr, value);
+
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+ }
+ }
+ } while (0);
+
+ FREE_OP(free_op_data1);
+ if (UNEXPECTED(free_op1)) {zval_ptr_dtor_nogc(free_op1);};
+ ZEND_VM_NEXT_OPCODE_EX(1, 2);
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_CV(binary_op_type binary_op ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
zend_free_op free_op1;
}
}
- zval_ptr_dtor_nogc(&free_op1.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (UNEXPECTED(free_op1)) {zval_ptr_dtor_nogc(free_op1);};
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || (IS_CV != IS_UNUSED)
USE_OPLINE
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- /* Behave like FETCH_OBJ_W */
- zend_free_op free_op1, free_op2;
- zval *property;
- zval **container;
+# if 0 || (IS_VAR != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_VAR_CV(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_CV(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_VAR_CV(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_CV(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- SAVE_OPLINE();
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC);
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || (IS_CV != IS_UNUSED)
+ USE_OPLINE
- if (1) {
- MAKE_REAL_ZVAL_PTR(property);
- }
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
- zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
- if (1) {
- zval_ptr_dtor(&property);
- } else {
- zval_dtor(free_op2.var);
- }
- if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
- EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
- }
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- } else {
- return zend_fetch_property_address_read_helper_SPEC_VAR_TMP(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+# if 0 || (IS_VAR != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_VAR_CV(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_CV(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_VAR_CV(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_CV(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_UNSET_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || (IS_CV != IS_UNUSED)
USE_OPLINE
- zend_free_op free_op1, free_op2, free_res;
- zval **container;
- zval *property;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC);
- if (IS_VAR == IS_CV) {
- if (container != &EG(uninitialized_zval_ptr)) {
- SEPARATE_ZVAL_IF_NOT_REF(container);
- }
- }
- if (1) {
- MAKE_REAL_ZVAL_PTR(property);
+# if 0 || (IS_VAR != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_VAR_CV(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_CV(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_VAR_CV(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
- zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_UNSET TSRMLS_CC);
- if (1) {
- zval_ptr_dtor(&property);
- } else {
- zval_dtor(free_op2.var);
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_CV(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
+
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || (IS_CV != IS_UNUSED)
+ USE_OPLINE
+
+# if 0 || (IS_VAR != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_VAR_CV(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
- if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
- EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_CV(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_VAR_CV(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_CV(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
+
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || (IS_CV != IS_UNUSED)
+ USE_OPLINE
- PZVAL_UNLOCK(*EX_T(opline->result.var).var.ptr_ptr, &free_res);
- if (EX_T(opline->result.var).var.ptr_ptr != &EG(uninitialized_zval_ptr)) {
- SEPARATE_ZVAL_IF_NOT_REF(EX_T(opline->result.var).var.ptr_ptr);
+# if 0 || (IS_VAR != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_VAR_CV(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
- PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
- FREE_OP_VAR_PTR(free_res);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_CV(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_VAR_CV(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_CV(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_ASSIGN_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || (IS_CV != IS_UNUSED)
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval **object_ptr;
- zval *property_name;
-
- SAVE_OPLINE();
- object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
- property_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC);
- if (1) {
- MAKE_REAL_ZVAL_PTR(property_name);
- }
- if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+# if 0 || (IS_VAR != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_VAR_CV(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
- zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- if (1) {
- zval_ptr_dtor(&property_name);
- } else {
- zval_dtor(free_op2.var);
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_CV(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_VAR_CV(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- /* assign_obj has two opcodes! */
- CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_CV(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_ASSIGN_DIM_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || (IS_CV != IS_UNUSED)
USE_OPLINE
- zend_free_op free_op1;
- zval **object_ptr;
- SAVE_OPLINE();
- object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
-
- if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+# if 0 || (IS_VAR != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_VAR_CV(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
- if (Z_TYPE_PP(object_ptr) == IS_OBJECT) {
- zend_free_op free_op2;
- zval *property_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC);
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_CV(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_VAR_CV(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_CV(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- if (1) {
- MAKE_REAL_ZVAL_PTR(property_name);
- }
- zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- if (1) {
- zval_ptr_dtor(&property_name);
- } else {
- zval_dtor(free_op2.var);
- }
- } else {
- zend_free_op free_op2, free_op_data1, free_op_data2;
- zval *value;
- zval *dim = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC);
- zval **variable_ptr_ptr;
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || (IS_CV != IS_UNUSED)
+ USE_OPLINE
- zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), object_ptr, dim, IS_TMP_VAR, BP_VAR_W TSRMLS_CC);
- zval_dtor(free_op2.var);
+# if 0 || (IS_VAR != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_VAR_CV(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_CV(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_VAR_CV(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_CV(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- variable_ptr_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, execute_data, &free_op_data2 TSRMLS_CC);
- if (UNEXPECTED(variable_ptr_ptr == NULL)) {
- if (zend_assign_to_string_offset(&EX_T((opline+1)->op2.var), value, (opline+1)->op1_type TSRMLS_CC)) {
- if (RETURN_VALUE_USED(opline)) {
- zval *retval;
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || (IS_CV != IS_UNUSED)
+ USE_OPLINE
- ALLOC_ZVAL(retval);
- ZVAL_STRINGL(retval, Z_STRVAL_P(EX_T((opline+1)->op2.var).str_offset.str)+EX_T((opline+1)->op2.var).str_offset.offset, 1, 1);
- INIT_PZVAL(retval);
- EX_T(opline->result.var).var.ptr = retval;
- }
- } else if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
- }
- } else if (UNEXPECTED(*variable_ptr_ptr == &EG(error_zval))) {
- if (IS_TMP_FREE(free_op_data1)) {
- zval_dtor(value);
- }
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
- }
- } else {
- if ((opline+1)->op1_type == IS_TMP_VAR) {
- value = zend_assign_tmp_to_variable(variable_ptr_ptr, value TSRMLS_CC);
- } else if ((opline+1)->op1_type == IS_CONST) {
- value = zend_assign_const_to_variable(variable_ptr_ptr, value TSRMLS_CC);
- } else {
- value = zend_assign_to_variable(variable_ptr_ptr, value TSRMLS_CC);
- }
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(value);
- EX_T(opline->result.var).var.ptr = value;
- }
- }
- FREE_OP_VAR_PTR(free_op_data2);
- FREE_OP_IF_VAR(free_op_data1);
+# if 0 || (IS_VAR != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_VAR_CV(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- /* assign_dim has two opcodes! */
- CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_CV(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_VAR_CV(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_CV(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_ASSIGN_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || (IS_CV != IS_UNUSED)
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *value;
- zval **variable_ptr_ptr;
- SAVE_OPLINE();
- value = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC);
- variable_ptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
+# if 0 || (IS_VAR != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_VAR_CV(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_CV(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_VAR_CV(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_CV(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- if (IS_VAR == IS_VAR && UNEXPECTED(variable_ptr_ptr == NULL)) {
- if (zend_assign_to_string_offset(&EX_T(opline->op1.var), value, IS_TMP_VAR TSRMLS_CC)) {
- if (RETURN_VALUE_USED(opline)) {
- zval *retval;
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || (IS_CV != IS_UNUSED)
+ USE_OPLINE
- ALLOC_ZVAL(retval);
- ZVAL_STRINGL(retval, Z_STRVAL_P(EX_T(opline->op1.var).str_offset.str)+EX_T(opline->op1.var).str_offset.offset, 1, 1);
- INIT_PZVAL(retval);
- EX_T(opline->result.var).var.ptr = retval;
- }
- } else if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
- }
- } else if (IS_VAR == IS_VAR && UNEXPECTED(*variable_ptr_ptr == &EG(error_zval))) {
- if (1) {
- zval_dtor(value);
- }
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
- }
- } else {
- if (IS_TMP_VAR == IS_TMP_VAR) {
- value = zend_assign_tmp_to_variable(variable_ptr_ptr, value TSRMLS_CC);
- } else if (IS_TMP_VAR == IS_CONST) {
- value = zend_assign_const_to_variable(variable_ptr_ptr, value TSRMLS_CC);
- } else {
- value = zend_assign_to_variable(variable_ptr_ptr, value TSRMLS_CC);
- }
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(value);
- EX_T(opline->result.var).var.ptr = value;
- }
+# if 0 || (IS_VAR != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_VAR_CV(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-
- if (IS_VAR == IS_VAR && (free_op1.var != NULL)) {
- zval_ptr_dtor_nogc(&value);
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_CV(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_VAR_CV(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_CV(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- /* zend_assign_to_variable() always takes care of op2, never free it! */
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || (IS_CV != IS_UNUSED)
+ USE_OPLINE
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+# if 0 || (IS_VAR != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_VAR_CV(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_CV(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_VAR_CV(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_CV(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_CV(int inc ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
- zval *function_name;
- char *function_name_strval;
- int function_name_strlen;
- zend_free_op free_op1, free_op2;
- call_slot *call = EX(call_slots) + opline->result.num;
+ zend_free_op free_op1;
+ zval *object;
+ zval *property;
+ zval *zptr;
SAVE_OPLINE();
+ object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- function_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC);
+ if (IS_VAR == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
- if (IS_TMP_VAR != IS_CONST &&
- UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- zend_error_noreturn(E_ERROR, "Method name must be a string");
+ HANDLE_EXCEPTION();
}
- function_name_strval = Z_STRVAL_P(function_name);
- function_name_strlen = Z_STRLEN_P(function_name);
-
- call->object = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
+ property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var);
- if (EXPECTED(call->object != NULL) &&
- EXPECTED(Z_TYPE_P(call->object) == IS_OBJECT)) {
- call->called_scope = Z_OBJCE_P(call->object);
+ if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot increment/decrement overloaded objects nor string offsets");
- if (IS_TMP_VAR != IS_CONST ||
- (call->fbc = CACHED_POLYMORPHIC_PTR(opline->op2.literal->cache_slot, call->called_scope)) == NULL) {
- zval *object = call->object;
-
- if (UNEXPECTED(Z_OBJ_HT_P(call->object)->get_method == NULL)) {
- zend_error_noreturn(E_ERROR, "Object does not support method calls");
- }
+ HANDLE_EXCEPTION();
+ }
- /* First, locate the function. */
- call->fbc = Z_OBJ_HT_P(call->object)->get_method(&call->object, function_name_strval, function_name_strlen, ((IS_TMP_VAR == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
- if (UNEXPECTED(call->fbc == NULL)) {
- zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", Z_OBJ_CLASS_NAME_P(call->object), function_name_strval);
- }
- if (IS_TMP_VAR == IS_CONST &&
- EXPECTED(call->fbc->type <= ZEND_USER_FUNCTION) &&
- EXPECTED((call->fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
- EXPECTED(call->object == object)) {
- CACHE_POLYMORPHIC_PTR(opline->op2.literal->cache_slot, call->called_scope, call->fbc);
+ do {
+ if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ break;
}
}
- } else {
- if (UNEXPECTED(EG(exception) != NULL)) {
- zval_dtor(free_op2.var);
- HANDLE_EXCEPTION();
- }
- zend_error_noreturn(E_ERROR, "Call to a member function %s() on %s", function_name_strval, zend_get_type_by_const(Z_TYPE_P(call->object)));
- }
- if ((call->fbc->common.fn_flags & ZEND_ACC_STATIC) != 0) {
- call->object = NULL;
- } else {
- if (!PZVAL_IS_REF(call->object)) {
- Z_ADDREF_P(call->object); /* For $this pointer */
+ /* here we are sure we are dealing with an object */
-
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CV == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
-
- if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
- if (inc) {
- fast_long_increment_function(zptr);
- } else {
- fast_long_decrement_function(zptr);
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
-
- if (inc) {
- increment_function(zptr);
++ if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
++ if (inc) {
++ fast_long_increment_function(zptr);
++ } else {
++ fast_long_decrement_function(zptr);
++ }
+ } else {
- decrement_function(zptr);
++ ZVAL_DEREF(zptr);
++ SEPARATE_ZVAL_NOREF(zptr);
++
++ if (inc) {
++ increment_function(zptr);
++ } else {
++ decrement_function(zptr);
++ }
++ }
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_COPY(EX_VAR(opline->result.var), zptr);
+ }
- }
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), zptr);
+ }
} else {
- zval *this_ptr;
- ALLOC_ZVAL(this_ptr);
- INIT_PZVAL_COPY(this_ptr, call->object);
- zval_copy_ctor(this_ptr);
- call->object = this_ptr;
+ zend_pre_incdec_overloaded_property(object, property, ((IS_CV == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), inc, (UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL));
}
- }
+ } while (0);
- call->num_additional_args = 0;
- call->is_ctor_call = 0;
- EX(call) = call;
+ if (UNEXPECTED(free_op1)) {zval_ptr_dtor_nogc(free_op1);};
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
+}
- zval_dtor(free_op2.var);
- zval_ptr_dtor_nogc(&free_op1.var);
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ ZEND_VM_TAIL_CALL(zend_pre_incdec_property_helper_SPEC_VAR_CV(1 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ ZEND_VM_TAIL_CALL(zend_pre_incdec_property_helper_SPEC_VAR_CV(0 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_CV(int inc ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
- zval *function_name;
- zend_class_entry *ce;
- call_slot *call = EX(call_slots) + opline->result.num;
+ zend_free_op free_op1;
+ zval *object;
+ zval *property;
+ zval *zptr;
SAVE_OPLINE();
+ object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (IS_VAR == IS_CONST) {
- /* no function found. try a static method in class */
- if (CACHED_PTR(opline->op1.literal->cache_slot)) {
- ce = CACHED_PTR(opline->op1.literal->cache_slot);
- } else {
- ce = zend_fetch_class_by_name(Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), opline->op1.literal + 1, opline->extended_value TSRMLS_CC);
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- if (UNEXPECTED(ce == NULL)) {
- zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
- }
- CACHE_PTR(opline->op1.literal->cache_slot, ce);
- }
- call->called_scope = ce;
- } else {
- ce = EX_T(opline->op1.var).class_entry;
+ if (IS_VAR == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
- if (opline->extended_value == ZEND_FETCH_CLASS_PARENT || opline->extended_value == ZEND_FETCH_CLASS_SELF) {
- call->called_scope = EG(called_scope);
- } else {
- call->called_scope = ce;
- }
+ HANDLE_EXCEPTION();
}
- if (IS_VAR == IS_CONST &&
- IS_TMP_VAR == IS_CONST &&
- CACHED_PTR(opline->op2.literal->cache_slot)) {
- call->fbc = CACHED_PTR(opline->op2.literal->cache_slot);
- } else if (IS_VAR != IS_CONST &&
- IS_TMP_VAR == IS_CONST &&
- (call->fbc = CACHED_POLYMORPHIC_PTR(opline->op2.literal->cache_slot, ce))) {
- /* do nothing */
- } else if (IS_TMP_VAR != IS_UNUSED) {
- char *function_name_strval = NULL;
- int function_name_strlen = 0;
- zend_free_op free_op2;
+ property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var);
- if (IS_TMP_VAR == IS_CONST) {
- function_name_strval = Z_STRVAL_P(opline->op2.zv);
- function_name_strlen = Z_STRLEN_P(opline->op2.zv);
- } else {
- function_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC);
+ if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot increment/decrement overloaded objects nor string offsets");
- if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- zend_error_noreturn(E_ERROR, "Function name must be a string");
- } else {
- function_name_strval = Z_STRVAL_P(function_name);
- function_name_strlen = Z_STRLEN_P(function_name);
- }
+ HANDLE_EXCEPTION();
+ }
+
+ do {
+ if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ break;
+ }
}
- if (function_name_strval) {
- if (ce->get_static_method) {
- call->fbc = ce->get_static_method(ce, function_name_strval, function_name_strlen TSRMLS_CC);
+ /* here we are sure we are dealing with an object */
+
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CV == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
-
- if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
- if (inc) {
- fast_long_increment_function(zptr);
- } else {
- fast_long_decrement_function(zptr);
- }
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
} else {
- ZVAL_DEREF(zptr);
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
- zval_opt_copy_ctor(zptr);
- if (inc) {
- increment_function(zptr);
- call->fbc = zend_std_get_static_method(ce, function_name_strval, function_name_strlen, ((IS_TMP_VAR == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
- }
- if (UNEXPECTED(call->fbc == NULL)) {
- zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name, function_name_strval);
- }
- if (IS_TMP_VAR == IS_CONST &&
- EXPECTED(call->fbc->type <= ZEND_USER_FUNCTION) &&
- EXPECTED((call->fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0)) {
- if (IS_VAR == IS_CONST) {
- CACHE_PTR(opline->op2.literal->cache_slot, call->fbc);
++ if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
++ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
++ if (inc) {
++ fast_long_increment_function(zptr);
++ } else {
++ fast_long_decrement_function(zptr);
++ }
} else {
- decrement_function(zptr);
- CACHE_POLYMORPHIC_PTR(opline->op2.literal->cache_slot, ce, call->fbc);
++ ZVAL_DEREF(zptr);
++ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
++ zval_opt_copy_ctor(zptr);
++ if (inc) {
++ increment_function(zptr);
++ } else {
++ decrement_function(zptr);
++ }
}
}
+ } else {
+ zend_post_incdec_overloaded_property(object, property, ((IS_CV == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), inc, EX_VAR(opline->result.var));
}
- if (IS_TMP_VAR != IS_CONST) {
- zval_dtor(free_op2.var);
- }
- } else {
- if (UNEXPECTED(ce->constructor == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot call constructor");
- }
- if (EG(This) && Z_OBJCE_P(EG(This)) != ce->constructor->common.scope && (ce->constructor->common.fn_flags & ZEND_ACC_PRIVATE)) {
- zend_error_noreturn(E_ERROR, "Cannot call private %s::__construct()", ce->name);
- }
- call->fbc = ce->constructor;
- }
+ } while (0);
- if (call->fbc->common.fn_flags & ZEND_ACC_STATIC) {
- call->object = NULL;
- } else {
- if (EG(This) &&
- Z_OBJ_HT_P(EG(This))->get_class_entry &&
- !instanceof_function(Z_OBJCE_P(EG(This)), ce TSRMLS_CC)) {
- /* We are calling method of the other (incompatible) class,
- but passing $this. This is done for compatibility with php-4. */
- if (call->fbc->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
- zend_error(E_DEPRECATED, "Non-static method %s::%s() should not be called statically, assuming $this from incompatible context", call->fbc->common.scope->name, call->fbc->common.function_name);
- } else {
- /* An internal function assumes $this is present and won't check that. So PHP would crash by allowing the call. */
- zend_error_noreturn(E_ERROR, "Non-static method %s::%s() cannot be called statically, assuming $this from incompatible context", call->fbc->common.scope->name, call->fbc->common.function_name);
- }
- }
- if ((call->object = EG(This))) {
- Z_ADDREF_P(call->object);
- call->called_scope = Z_OBJCE_P(call->object);
- }
- }
+ if (UNEXPECTED(free_op1)) {zval_ptr_dtor_nogc(free_op1);};
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
+}
- call->num_additional_args = 0;
- call->is_ctor_call = 0;
- EX(call) = call;
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ ZEND_VM_TAIL_CALL(zend_post_incdec_property_helper_SPEC_VAR_CV(1 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ ZEND_VM_TAIL_CALL(zend_post_incdec_property_helper_SPEC_VAR_CV(0 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL ZEND_CASE_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_FETCH_DIM_W_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
+ zval *container;
SAVE_OPLINE();
- is_equal_function(&EX_T(opline->result.var).tmp_var,
- _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC) TSRMLS_CC);
+ container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- zval_dtor(free_op2.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_throw_error(NULL, "Cannot use string offset as an array");
+ HANDLE_EXCEPTION();
+ }
+ zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var), IS_CV);
+
+ if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var), 1);
+ }
+ if (UNEXPECTED(free_op1)) {zval_ptr_dtor_nogc(free_op1);};
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_FETCH_DIM_RW_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
}
}
}
+ } else {
+ /* If no value was specified yield null */
+ ZVAL_NULL(&generator->value);
}
- if (!have_get_ptr) {
- if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval *z;
-
- Z_ADDREF_P(object);
- z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+ /* Set the new yielded key */
+ if (IS_CV != IS_UNUSED) {
- if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
- zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
+ zval *key = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var);
- if (Z_REFCOUNT_P(z) == 0) {
- GC_REMOVE_ZVAL_FROM_BUFFER(z);
- zval_dtor(z);
- FREE_ZVAL(z);
- }
- z = value;
+ /* Consts, temporary variables and references need copying */
+ if (IS_CV == IS_CONST) {
+ ZVAL_COPY_VALUE(&generator->key, key);
+ if (UNEXPECTED(Z_OPT_COPYABLE(generator->key))) {
+ zval_copy_ctor_func(&generator->key);
}
- Z_ADDREF_P(z);
- SEPARATE_ZVAL_IF_NOT_REF(&z);
- incdec_op(z);
- *retval = z;
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- zval_ptr_dtor(&object);
- SELECTIVE_PZVAL_LOCK(*retval, opline);
- zval_ptr_dtor(&z);
+ } else if (IS_CV == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&generator->key, key);
+ } else if ((IS_CV & (IS_VAR|IS_CV)) && Z_ISREF_P(key)) {
+ ZVAL_COPY(&generator->key, Z_REFVAL_P(key));
+
} else {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- *retval = &EG(uninitialized_zval);
+ ZVAL_COPY_VALUE(&generator->key, key);
+ if (IS_CV == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
}
}
+
+ if (Z_TYPE(generator->key) == IS_LONG
+ && Z_LVAL(generator->key) > generator->largest_used_integer_key
+ ) {
+ generator->largest_used_integer_key = Z_LVAL(generator->key);
+ }
+ } else {
+ /* If no key was specified we use auto-increment keys */
+ generator->largest_used_integer_key++;
+ ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
}
- if (0) {
- zval_ptr_dtor(&property);
+ if (RETURN_VALUE_USED(opline)) {
+ /* If the return value of yield is used set the send
+ * target and initialize it to NULL */
+ generator->send_target = EX_VAR(opline->result.var);
+ ZVAL_NULL(generator->send_target);
} else {
- zval_ptr_dtor_nogc(&free_op2.var);
+ generator->send_target = NULL;
}
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-static int ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_pre_incdec_property_helper_SPEC_VAR_VAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ /* We increment to the next op, so we are at the correct position when the
+ * generator is resumed. */
+ ZEND_VM_INC_OPCODE();
-static int ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_pre_incdec_property_helper_SPEC_VAR_VAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ /* The GOTO VM uses a local opline variable. We need to set the opline
+ * variable in execute_data so we don't resume at an old position. */
+ SAVE_OPLINE();
+
+ ZEND_VM_RETURN();
}
-static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_VAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_TMPVAR(binary_op_type binary_op ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval **object_ptr;
+ zend_free_op free_op1, free_op2, free_op_data1;
zval *object;
zval *property;
- zval *retval;
- int have_get_ptr = 0;
+ zval *value;
+ zval *zptr;
SAVE_OPLINE();
- object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
- property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2 TSRMLS_CC);
- retval = &EX_T(opline->result.var).tmp_var;
+ object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
-
- make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
- object = *object_ptr;
-
- if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- zval_ptr_dtor_nogc(&free_op2.var);
- ZVAL_NULL(retval);
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (IS_VAR == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
+ zval_ptr_dtor_nogc(EX_VAR(opline->op2.var));
+ HANDLE_EXCEPTION();
}
- /* here we are sure we are dealing with an object */
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (0) {
- MAKE_REAL_ZVAL_PTR(property);
+ if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot use string offset as an object");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
+ zval_ptr_dtor_nogc(free_op2);
+ HANDLE_EXCEPTION();
}
- if (Z_OBJ_HT_P(object)->get_property_ptr_ptr) {
- zval **zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- if (zptr != NULL) { /* NULL means no success in getting PTR */
- have_get_ptr = 1;
- if (UNEXPECTED(*zptr == &EG(error_zval))) {
- ZVAL_NULL(retval);
- } else {
- SEPARATE_ZVAL_IF_NOT_REF(zptr);
-
- ZVAL_COPY_VALUE(retval, *zptr);
- zendi_zval_copy_ctor(*retval);
+ do {
+ value = get_zval_ptr_r((opline+1)->op1_type, (opline+1)->op1, execute_data, &free_op_data1);
- incdec_op(*zptr);
+ if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to assign property of non-object");
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ break;
}
}
- }
-
- if (!have_get_ptr) {
- if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval *z, *z_copy;
- Z_ADDREF_P(object);
- z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
- zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
+ /* here we are sure we are dealing with an object */
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
++ }
++ } else {
++ ZVAL_DEREF(zptr);
++ SEPARATE_ZVAL_NOREF(zptr);
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
-
- binary_op(zptr, zptr, value);
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), zptr);
- if (Z_REFCOUNT_P(z) == 0) {
- GC_REMOVE_ZVAL_FROM_BUFFER(z);
- zval_dtor(z);
- FREE_ZVAL(z);
++ binary_op(zptr, zptr, value);
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_COPY(EX_VAR(opline->result.var), zptr);
+ }
- z = value;
}
- ZVAL_COPY_VALUE(retval, z);
- zendi_zval_copy_ctor(*retval);
- ALLOC_ZVAL(z_copy);
- INIT_PZVAL_COPY(z_copy, z);
- zendi_zval_copy_ctor(*z_copy);
- incdec_op(z_copy);
- Z_ADDREF_P(z);
- Z_OBJ_HT_P(object)->write_property(object, property, z_copy, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- zval_ptr_dtor(&object);
- zval_ptr_dtor(&z_copy);
- zval_ptr_dtor(&z);
} else {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- ZVAL_NULL(retval);
+ zend_assign_op_overloaded_property(object, property, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), value, binary_op, (UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL));
}
- }
-
- if (0) {
- zval_ptr_dtor(&property);
- } else {
- zval_ptr_dtor_nogc(&free_op2.var);
- }
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_post_incdec_property_helper_SPEC_VAR_VAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ } while (0);
-static int ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_post_incdec_property_helper_SPEC_VAR_VAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ FREE_OP(free_op_data1);
+ zval_ptr_dtor_nogc(free_op2);
+ if (UNEXPECTED(free_op1)) {zval_ptr_dtor_nogc(free_op1);};
+ /* assign_obj has two opcodes! */
+ ZEND_VM_NEXT_OPCODE_EX(1, 2);
}
-static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_VAR_VAR(int type, ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_VAR_TMPVAR(binary_op_type binary_op ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *varname;
- zval **retval;
- zval tmp_varname;
- HashTable *target_symbol_table;
- ulong hash_value;
+ zend_free_op free_op1, free_op2, free_op_data1;
+ zval *var_ptr, rv;
+ zval *value, *container, *dim;
SAVE_OPLINE();
- varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
-
- if (IS_VAR != IS_CONST && UNEXPECTED(Z_TYPE_P(varname) != IS_STRING)) {
- ZVAL_COPY_VALUE(&tmp_varname, varname);
- zval_copy_ctor(&tmp_varname);
- Z_SET_REFCOUNT(tmp_varname, 1);
- Z_UNSET_ISREF(tmp_varname);
- convert_to_string(&tmp_varname);
- varname = &tmp_varname;
+ container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+ if (IS_VAR == IS_UNUSED && UNEXPECTED(Z_OBJ_P(container) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
+ zval_ptr_dtor_nogc(EX_VAR(opline->op2.var));
+ HANDLE_EXCEPTION();
+ }
+ if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_throw_error(NULL, "Cannot use string offset as an array");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
+ zval_ptr_dtor_nogc(EX_VAR(opline->op2.var));
+ HANDLE_EXCEPTION();
}
- if (IS_VAR != IS_UNUSED) {
- zend_class_entry *ce;
-
- if (IS_VAR == IS_CONST) {
- if (CACHED_PTR(opline->op2.literal->cache_slot)) {
- ce = CACHED_PTR(opline->op2.literal->cache_slot);
- } else {
- ce = zend_fetch_class_by_name(Z_STRVAL_P(opline->op2.zv), Z_STRLEN_P(opline->op2.zv), opline->op2.literal + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- if (IS_VAR != IS_CONST && varname == &tmp_varname) {
- zval_dtor(&tmp_varname);
- }
- zval_ptr_dtor_nogc(&free_op1.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
- CACHE_PTR(opline->op2.literal->cache_slot, ce);
- }
- } else {
- ce = EX_T(opline->op2.var).class_entry;
- }
- retval = zend_std_get_static_property(ce, Z_STRVAL_P(varname), Z_STRLEN_P(varname), 0, ((IS_VAR == IS_CONST) ? opline->op1.literal : NULL) TSRMLS_CC);
- zval_ptr_dtor_nogc(&free_op1.var);
- } else {
- target_symbol_table = zend_get_target_symbol_table(opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-/*
- if (!target_symbol_table) {
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-*/
- if (IS_VAR == IS_CONST) {
- hash_value = Z_HASH_P(varname);
- } else {
- hash_value = str_hash(Z_STRVAL_P(varname), Z_STRLEN_P(varname));
- }
+ dim = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (zend_hash_quick_find(target_symbol_table, Z_STRVAL_P(varname), Z_STRLEN_P(varname)+1, hash_value, (void **) &retval) == FAILURE) {
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_UNSET:
- zend_error(E_NOTICE,"Undefined variable: %s", Z_STRVAL_P(varname));
- /* break missing intentionally */
- case BP_VAR_IS:
- retval = &EG(uninitialized_zval_ptr);
- break;
- case BP_VAR_RW:
- zend_error(E_NOTICE,"Undefined variable: %s", Z_STRVAL_P(varname));
- /* break missing intentionally */
- case BP_VAR_W:
- Z_ADDREF_P(&EG(uninitialized_zval));
- zend_hash_quick_update(target_symbol_table, Z_STRVAL_P(varname), Z_STRLEN_P(varname)+1, hash_value, &EG(uninitialized_zval_ptr), sizeof(zval *), (void **) &retval);
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
+ do {
+ if (IS_VAR == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) != IS_ARRAY)) {
+ if (IS_VAR != IS_UNUSED) {
+ ZVAL_DEREF(container);
}
- }
- switch (opline->extended_value & ZEND_FETCH_TYPE_MASK) {
- case ZEND_FETCH_GLOBAL:
- if (IS_VAR != IS_TMP_VAR) {
- zval_ptr_dtor_nogc(&free_op1.var);
- }
- break;
- case ZEND_FETCH_LOCAL:
- zval_ptr_dtor_nogc(&free_op1.var);
- break;
- case ZEND_FETCH_STATIC:
- zval_update_constant(retval, 1 TSRMLS_CC);
- break;
- case ZEND_FETCH_GLOBAL_LOCK:
- if (IS_VAR == IS_VAR && !free_op1.var) {
- PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
- }
+ if (IS_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ value = get_zval_ptr_r((opline+1)->op1_type, (opline+1)->op1, execute_data, &free_op_data1);
+ zend_binary_assign_op_obj_dim(container, dim, value, UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL, binary_op);
break;
+ }
}
- }
+ zend_fetch_dimension_address_RW(&rv, container, dim, (IS_TMP_VAR|IS_VAR));
+ value = get_zval_ptr_r((opline+1)->op1_type, (opline+1)->op1, execute_data, &free_op_data1);
+ ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+ var_ptr = Z_INDIRECT(rv);
- if (IS_VAR != IS_CONST && varname == &tmp_varname) {
- zval_dtor(&tmp_varname);
- }
- if (opline->extended_value & ZEND_FETCH_MAKE_REF) {
- SEPARATE_ZVAL_TO_MAKE_IS_REF(retval);
- }
- PZVAL_LOCK(*retval);
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_IS:
- EX_T(opline->result.var).var.ptr = *retval;
- break;
- case BP_VAR_UNSET: {
- zend_free_op free_res;
+ if (UNEXPECTED(var_ptr == NULL)) {
+ zend_throw_error(NULL, "Cannot use assign-op operators with overloaded objects nor string offsets");
+ zval_ptr_dtor_nogc(free_op2);
+ FREE_OP(free_op_data1);
+ if (UNEXPECTED(free_op1)) {zval_ptr_dtor_nogc(free_op1);};
+ HANDLE_EXCEPTION();
+ }
- PZVAL_UNLOCK(*retval, &free_res);
- if (retval != &EG(uninitialized_zval_ptr)) {
- SEPARATE_ZVAL_IF_NOT_REF(retval);
+ if (UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
}
- PZVAL_LOCK(*retval);
- FREE_OP_VAR_PTR(free_res);
- }
- /* break missing intentionally */
- default:
- EX_T(opline->result.var).var.ptr_ptr = retval;
- break;
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ } else {
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
-static int ZEND_FASTCALL ZEND_FETCH_R_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_VAR_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ binary_op(var_ptr, var_ptr, value);
-static int ZEND_FASTCALL ZEND_FETCH_W_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_VAR_VAR(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+ }
+ }
+ } while (0);
-static int ZEND_FASTCALL ZEND_FETCH_RW_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_VAR_VAR(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ zval_ptr_dtor_nogc(free_op2);
+ FREE_OP(free_op_data1);
+ if (UNEXPECTED(free_op1)) {zval_ptr_dtor_nogc(free_op1);};
+ ZEND_VM_NEXT_OPCODE_EX(1, 2);
}
-static int ZEND_FASTCALL ZEND_FETCH_FUNC_ARG_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_TMPVAR(binary_op_type binary_op ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
+ zend_free_op free_op1, free_op2;
+ zval *var_ptr;
+ zval *value;
- return zend_fetch_var_address_helper_SPEC_VAR_VAR(zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC) ? BP_VAR_W : BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ SAVE_OPLINE();
+ value = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-static int ZEND_FASTCALL ZEND_FETCH_UNSET_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+ if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+ zend_throw_error(NULL, "Cannot use assign-op operators with overloaded objects nor string offsets");
+ zval_ptr_dtor_nogc(free_op2);
+ HANDLE_EXCEPTION();
+ }
+
+ if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
+
+ binary_op(var_ptr, var_ptr, value);
+
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+ }
+ }
+
+ zval_ptr_dtor_nogc(free_op2);
+ if (UNEXPECTED(free_op1)) {zval_ptr_dtor_nogc(free_op1);};
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
+}
+
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_fetch_var_address_helper_SPEC_VAR_VAR(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
+
+# if 0 || (IS_VAR != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_VAR_TMPVAR(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_TMPVAR(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_VAR_TMPVAR(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_TMPVAR(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_FETCH_IS_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_fetch_var_address_helper_SPEC_VAR_VAR(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
+
+# if 0 || (IS_VAR != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_VAR_TMPVAR(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_TMPVAR(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_VAR_TMPVAR(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_TMPVAR(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *container;
- SAVE_OPLINE();
- container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
- zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2 TSRMLS_CC), IS_VAR, BP_VAR_R TSRMLS_CC);
- zval_ptr_dtor_nogc(&free_op2.var);
- if (IS_VAR != IS_VAR || !(opline->extended_value & ZEND_FETCH_ADD_LOCK)) {
- zval_ptr_dtor_nogc(&free_op1.var);
+# if 0 || (IS_VAR != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_VAR_TMPVAR(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_TMPVAR(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_VAR_TMPVAR(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_TMPVAR(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_W_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval **container;
- SAVE_OPLINE();
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
+# if 0 || (IS_VAR != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_VAR_TMPVAR(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_TMPVAR(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_VAR_TMPVAR(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_TMPVAR(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
+
+# if 0 || (IS_VAR != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_VAR_TMPVAR(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
- zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2 TSRMLS_CC), IS_VAR, BP_VAR_W TSRMLS_CC);
- zval_ptr_dtor_nogc(&free_op2.var);
- if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
- EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_TMPVAR(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_VAR_TMPVAR(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_TMPVAR(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- /* We are going to assign the result by reference */
- if (UNEXPECTED(opline->extended_value != 0)) {
- zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
- if (retval_ptr) {
- Z_DELREF_PP(retval_ptr);
- SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
- Z_ADDREF_PP(retval_ptr);
- }
+# if 0 || (IS_VAR != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_VAR_TMPVAR(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_TMPVAR(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_VAR_TMPVAR(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_TMPVAR(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
+
+# if 0 || (IS_VAR != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_VAR_TMPVAR(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_TMPVAR(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_VAR_TMPVAR(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_TMPVAR(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_RW_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval **container;
- SAVE_OPLINE();
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
+# if 0 || (IS_VAR != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_VAR_TMPVAR(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_TMPVAR(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_VAR_TMPVAR(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_TMPVAR(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
+
+# if 0 || (IS_VAR != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_VAR_TMPVAR(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
- zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2 TSRMLS_CC), IS_VAR, BP_VAR_RW TSRMLS_CC);
- zval_ptr_dtor_nogc(&free_op2.var);
- if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
- EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_TMPVAR(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_VAR_TMPVAR(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_TMPVAR(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_IS_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *container;
- SAVE_OPLINE();
- container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
- zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2 TSRMLS_CC), IS_VAR, BP_VAR_IS TSRMLS_CC);
- zval_ptr_dtor_nogc(&free_op2.var);
- zval_ptr_dtor_nogc(&free_op1.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+# if 0 || (IS_VAR != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_VAR_TMPVAR(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_TMPVAR(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_VAR_TMPVAR(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_TMPVAR(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
USE_OPLINE
- zend_free_op free_op1, free_op2;
- SAVE_OPLINE();
+# if 0 || (IS_VAR != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_VAR_TMPVAR(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_TMPVAR(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_VAR_TMPVAR(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_TMPVAR(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- zval **container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2 TSRMLS_CC), IS_VAR, BP_VAR_W TSRMLS_CC);
- if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
- EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
- }
- zval_ptr_dtor_nogc(&free_op2.var);
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- } else {
- zval *container;
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
- if (IS_VAR == IS_UNUSED) {
- zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
- }
- container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
- zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2 TSRMLS_CC), IS_VAR, BP_VAR_R TSRMLS_CC);
- zval_ptr_dtor_nogc(&free_op2.var);
- zval_ptr_dtor_nogc(&free_op1.var);
+# if 0 || (IS_VAR != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_VAR_TMPVAR(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_TMPVAR(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_VAR_TMPVAR(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_VAR_TMPVAR(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_UNSET_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_TMPVAR(int inc ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
- zval **container;
+ zval *object;
+ zval *property;
+ zval *zptr;
SAVE_OPLINE();
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
+ object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (IS_VAR == IS_CV) {
- if (container != &EG(uninitialized_zval_ptr)) {
- SEPARATE_ZVAL_IF_NOT_REF(container);
- }
- }
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ if (IS_VAR == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ zval_ptr_dtor_nogc(EX_VAR(opline->op2.var));
+ HANDLE_EXCEPTION();
}
- zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2 TSRMLS_CC), IS_VAR, BP_VAR_UNSET TSRMLS_CC);
- zval_ptr_dtor_nogc(&free_op2.var);
- if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
- EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
+
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+
+ if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot increment/decrement overloaded objects nor string offsets");
+ zval_ptr_dtor_nogc(free_op2);
+ HANDLE_EXCEPTION();
}
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- if (UNEXPECTED(EX_T(opline->result.var).var.ptr_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
- ZEND_VM_NEXT_OPCODE();
- } else {
- zend_free_op free_res;
- zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
- PZVAL_UNLOCK(*retval_ptr, &free_res);
- if (retval_ptr != &EG(uninitialized_zval_ptr)) {
- SEPARATE_ZVAL_IF_NOT_REF(retval_ptr);
+ do {
+ if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ break;
+ }
}
- PZVAL_LOCK(*retval_ptr);
- FREE_OP_VAR_PTR(free_res);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
+
+ /* here we are sure we are dealing with an object */
-
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
-
- if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
- if (inc) {
- fast_long_increment_function(zptr);
- } else {
- fast_long_decrement_function(zptr);
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
-
- if (inc) {
- increment_function(zptr);
++ if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
++ if (inc) {
++ fast_long_increment_function(zptr);
++ } else {
++ fast_long_decrement_function(zptr);
++ }
+ } else {
- decrement_function(zptr);
++ ZVAL_DEREF(zptr);
++ SEPARATE_ZVAL_NOREF(zptr);
++
++ if (inc) {
++ increment_function(zptr);
++ } else {
++ decrement_function(zptr);
++ }
++ }
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_COPY(EX_VAR(opline->result.var), zptr);
+ }
- }
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), zptr);
+ }
+ } else {
+ zend_pre_incdec_overloaded_property(object, property, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), inc, (UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL));
+ }
+ } while (0);
+
+ zval_ptr_dtor_nogc(free_op2);
+ if (UNEXPECTED(free_op1)) {zval_ptr_dtor_nogc(free_op1);};
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
+}
+
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ ZEND_VM_TAIL_CALL(zend_pre_incdec_property_helper_SPEC_VAR_TMPVAR(1 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+}
+
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ ZEND_VM_TAIL_CALL(zend_pre_incdec_property_helper_SPEC_VAR_TMPVAR(0 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_VAR_VAR(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_TMPVAR(int inc ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *container;
- zend_free_op free_op2;
- zval *offset;
+ zend_free_op free_op1, free_op2;
+ zval *object;
+ zval *property;
+ zval *zptr;
SAVE_OPLINE();
- container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2 TSRMLS_CC);
+ object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
- UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
- zend_error(E_NOTICE, "Trying to get property of non-object");
- PZVAL_LOCK(&EG(uninitialized_zval));
- EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
- zval_ptr_dtor_nogc(&free_op2.var);
- } else {
- zval *retval;
+ if (IS_VAR == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ zval_ptr_dtor_nogc(EX_VAR(opline->op2.var));
+ HANDLE_EXCEPTION();
+ }
+
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+
+ if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot increment/decrement overloaded objects nor string offsets");
+ zval_ptr_dtor_nogc(free_op2);
+ HANDLE_EXCEPTION();
+ }
- if (0) {
- MAKE_REAL_ZVAL_PTR(offset);
+ do {
+ if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ break;
+ }
}
/* here we are sure we are dealing with an object */
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- PZVAL_LOCK(retval);
- EX_T(opline->result.var).var.ptr = retval;
-
- if (0) {
- zval_ptr_dtor(&offset);
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
-
- if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
- if (inc) {
- fast_long_increment_function(zptr);
- } else {
- fast_long_decrement_function(zptr);
- }
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
+ } else {
- ZVAL_DEREF(zptr);
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
- zval_opt_copy_ctor(zptr);
- if (inc) {
- increment_function(zptr);
++ if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
++ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
++ if (inc) {
++ fast_long_increment_function(zptr);
++ } else {
++ fast_long_decrement_function(zptr);
++ }
+ } else {
- decrement_function(zptr);
++ ZVAL_DEREF(zptr);
++ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
++ zval_opt_copy_ctor(zptr);
++ if (inc) {
++ increment_function(zptr);
++ } else {
++ decrement_function(zptr);
++ }
+ }
+ }
} else {
- zval_ptr_dtor_nogc(&free_op2.var);
+ zend_post_incdec_overloaded_property(object, property, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), inc, EX_VAR(opline->result.var));
}
- }
+ } while (0);
- zval_ptr_dtor_nogc(&free_op1.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ zval_ptr_dtor_nogc(free_op2);
+ if (UNEXPECTED(free_op1)) {zval_ptr_dtor_nogc(free_op1);};
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_fetch_property_address_read_helper_SPEC_VAR_VAR(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_TAIL_CALL(zend_post_incdec_property_helper_SPEC_VAR_TMPVAR(1 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_W_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ ZEND_VM_TAIL_CALL(zend_post_incdec_property_helper_SPEC_VAR_TMPVAR(0 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+}
+
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_FETCH_DIM_W_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
}
}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL zend_isset_isempty_dim_prop_obj_handler_SPEC_VAR_VAR(int prop_dim, ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_EXIT_SPEC_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *container;
- zval **value = NULL;
- int result = 0;
- ulong hval;
- zval *offset;
SAVE_OPLINE();
- container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2 TSRMLS_CC);
-
- if (Z_TYPE_P(container) == IS_ARRAY && !prop_dim) {
- HashTable *ht;
- int isset = 0;
-
- ht = Z_ARRVAL_P(container);
-
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- goto num_index_prop;
- case IS_RESOURCE:
- case IS_BOOL:
- case IS_LONG:
- hval = Z_LVAL_P(offset);
-num_index_prop:
- if (zend_hash_index_find(ht, hval, (void **) &value) == SUCCESS) {
- isset = 1;
- }
- break;
- case IS_STRING:
- if (IS_VAR == IS_CONST) {
- hval = Z_HASH_P(offset);
- } else {
- ZEND_HANDLE_NUMERIC_EX(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, goto num_index_prop);
- hval = str_hash(Z_STRVAL_P(offset), Z_STRLEN_P(offset));
- }
- if (zend_hash_quick_find(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, (void **) &value) == SUCCESS) {
- isset = 1;
- }
- break;
- case IS_NULL:
- if (zend_hash_find(ht, "", sizeof(""), (void **) &value) == SUCCESS) {
- isset = 1;
- }
- break;
- default:
- zend_error(E_WARNING, "Illegal offset type in isset or empty");
- break;
- }
+ if (IS_UNUSED != IS_UNUSED) {
- if (opline->extended_value & ZEND_ISSET) {
- if (isset && Z_TYPE_PP(value) == IS_NULL) {
- result = 0;
- } else {
- result = isset;
- }
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- if (!isset || !i_zend_is_true(*value)) {
- result = 0;
- } else {
- result = 1;
- }
- }
- zval_ptr_dtor_nogc(&free_op2.var);
- } else if (Z_TYPE_P(container) == IS_OBJECT) {
- if (0) {
- MAKE_REAL_ZVAL_PTR(offset);
- }
- if (prop_dim) {
- if (Z_OBJ_HT_P(container)->has_property) {
- result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISEMPTY) != 0, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to check property of non-object");
- result = 0;
- }
- } else {
- if (Z_OBJ_HT_P(container)->has_dimension) {
- result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISEMPTY) != 0 TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to check element of non-array");
- result = 0;
- }
- }
- if (0) {
- zval_ptr_dtor(&offset);
- } else {
- zval_ptr_dtor_nogc(&free_op2.var);
- }
- } else if (Z_TYPE_P(container) == IS_STRING && !prop_dim) { /* string offsets */
- zval tmp;
+ zval *ptr = NULL;
- if (Z_TYPE_P(offset) != IS_LONG) {
- if (Z_TYPE_P(offset) <= IS_BOOL /* simple scalar types */
- || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
- && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
- ZVAL_COPY_VALUE(&tmp, offset);
- zval_copy_ctor(&tmp);
- convert_to_long(&tmp);
- offset = &tmp;
+ do {
+ if (Z_TYPE_P(ptr) == IS_LONG) {
+ EG(exit_status) = Z_LVAL_P(ptr);
} else {
- /* can not be converted to proper offset, return "not set" */
- result = 0;
- }
- }
- if (Z_TYPE_P(offset) == IS_LONG) {
- if (opline->extended_value & ZEND_ISSET) {
- if (offset->value.lval >= 0 && offset->value.lval < Z_STRLEN_P(container)) {
- result = 1;
- }
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- if (offset->value.lval >= 0 && offset->value.lval < Z_STRLEN_P(container) && Z_STRVAL_P(container)[offset->value.lval] != '0') {
- result = 1;
+ if ((IS_UNUSED & (IS_VAR|IS_CV)) && Z_ISREF_P(ptr)) {
+ ptr = Z_REFVAL_P(ptr);
+ if (Z_TYPE_P(ptr) == IS_LONG) {
+ EG(exit_status) = Z_LVAL_P(ptr);
+ break;
+ }
}
+ zend_print_variable(ptr);
}
- }
- zval_ptr_dtor_nogc(&free_op2.var);
- } else {
- zval_ptr_dtor_nogc(&free_op2.var);
- }
+ } while (0);
- Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
- if (opline->extended_value & ZEND_ISSET) {
- Z_LVAL(EX_T(opline->result.var).tmp_var) = result;
- } else {
- Z_LVAL(EX_T(opline->result.var).tmp_var) = !result;
}
-
- zval_ptr_dtor_nogc(&free_op1.var);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_isset_isempty_dim_prop_obj_handler_SPEC_VAR_VAR(0, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_isset_isempty_dim_prop_obj_handler_SPEC_VAR_VAR(1, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ zend_bailout();
+ ZEND_VM_NEXT_OPCODE(); /* Never reached */
}
-static int ZEND_FASTCALL ZEND_YIELD_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(binary_op_type binary_op ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
+ zend_free_op free_op_data1;
+ zval *object;
+ zval *property;
+ zval *value;
+ zval *zptr;
- /* The generator object is stored in return_value_ptr_ptr */
- zend_generator *generator = (zend_generator *) EG(return_value_ptr_ptr);
-
- if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
- zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
- }
+ SAVE_OPLINE();
+ object = _get_obj_zval_ptr_unused(execute_data);
- /* Destroy the previously yielded value */
- if (generator->value) {
- zval_ptr_dtor(&generator->value);
- }
+ if (IS_UNUSED == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
- /* Destroy the previously yielded key */
- if (generator->key) {
- zval_ptr_dtor(&generator->key);
+ HANDLE_EXCEPTION();
}
- /* Set the new yielded value */
- if (IS_VAR != IS_UNUSED) {
- zend_free_op free_op1;
+ property = EX_CONSTANT(opline->op2);
- if (EX(op_array)->fn_flags & ZEND_ACC_RETURN_REFERENCE) {
- /* Constants and temporary variables aren't yieldable by reference,
- * but we still allow them with a notice. */
- if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
- zval *value, *copy;
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot use string offset as an object");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
- zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+ HANDLE_EXCEPTION();
+ }
- value = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
- ALLOC_ZVAL(copy);
- INIT_PZVAL_COPY(copy, value);
+ do {
+ value = get_zval_ptr_r((opline+1)->op1_type, (opline+1)->op1, execute_data, &free_op_data1);
- /* Temporary variables don't need ctor copying */
- if (!0) {
- zval_copy_ctor(copy);
+ if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to assign property of non-object");
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
}
+ break;
+ }
+ }
- generator->value = copy;
+ /* here we are sure we are dealing with an object */
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
++ }
+ } else {
- zval **value_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
++ ZVAL_DEREF(zptr);
++ SEPARATE_ZVAL_NOREF(zptr);
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
-
- binary_op(zptr, zptr, value);
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), zptr);
- if (IS_VAR == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
++ binary_op(zptr, zptr, value);
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_COPY(EX_VAR(opline->result.var), zptr);
+ }
+ }
+ } else {
+ zend_assign_op_overloaded_property(object, property, ((IS_CONST == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), value, binary_op, (UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL));
+ }
+ } while (0);
- /* If a function call result is yielded and the function did
- * not return by reference we throw a notice. */
- if (IS_VAR == IS_VAR && !Z_ISREF_PP(value_ptr)
- && !(opline->extended_value == ZEND_RETURNS_FUNCTION
- && EX_T(opline->op1.var).var.fcall_returned_reference)
- && EX_T(opline->op1.var).var.ptr_ptr == &EX_T(opline->op1.var).var.ptr) {
- zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+ FREE_OP(free_op_data1);
- Z_ADDREF_PP(value_ptr);
- generator->value = *value_ptr;
- } else {
- SEPARATE_ZVAL_TO_MAKE_IS_REF(value_ptr);
- Z_ADDREF_PP(value_ptr);
- generator->value = *value_ptr;
- }
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- }
- } else {
- zval *value = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
+ /* assign_obj has two opcodes! */
+ ZEND_VM_NEXT_OPCODE_EX(1, 2);
+}
- /* Consts, temporary variables and references need copying */
- if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR
- || PZVAL_IS_REF(value)
- ) {
- zval *copy;
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(binary_op_type binary_op ZEND_OPCODE_HANDLER_ARGS_DC)
+{
+ USE_OPLINE
+ zend_free_op free_op_data1;
+ zval *var_ptr, rv;
+ zval *value, *container, *dim;
- ALLOC_ZVAL(copy);
- INIT_PZVAL_COPY(copy, value);
+ SAVE_OPLINE();
+ container = _get_obj_zval_ptr_unused(execute_data);
+ if (IS_UNUSED == IS_UNUSED && UNEXPECTED(Z_OBJ_P(container) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
- /* Temporary variables don't need ctor copying */
- if (!0) {
- zval_copy_ctor(copy);
- }
+ HANDLE_EXCEPTION();
+ }
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_throw_error(NULL, "Cannot use string offset as an array");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
- generator->value = copy;
- zval_ptr_dtor_nogc(&free_op1.var);
- } else {
- if (IS_VAR == IS_CV) {
- Z_ADDREF_P(value);
- }
- generator->value = value;
+ HANDLE_EXCEPTION();
+ }
+
+ dim = EX_CONSTANT(opline->op2);
+
+ do {
+ if (IS_UNUSED == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) != IS_ARRAY)) {
+ if (IS_UNUSED != IS_UNUSED) {
+ ZVAL_DEREF(container);
+ }
+ if (IS_UNUSED == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ value = get_zval_ptr_r((opline+1)->op1_type, (opline+1)->op1, execute_data, &free_op_data1);
+ zend_binary_assign_op_obj_dim(container, dim, value, UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL, binary_op);
+ break;
}
}
- } else {
- /* If no value was specified yield null */
- Z_ADDREF(EG(uninitialized_zval));
- generator->value = &EG(uninitialized_zval);
- }
- /* Set the new yielded key */
- if (IS_VAR != IS_UNUSED) {
- zend_free_op free_op2;
- zval *key = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2 TSRMLS_CC);
+ zend_fetch_dimension_address_RW(&rv, container, dim, IS_CONST);
+ value = get_zval_ptr_r((opline+1)->op1_type, (opline+1)->op1, execute_data, &free_op_data1);
+ ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+ var_ptr = Z_INDIRECT(rv);
- /* Consts, temporary variables and references need copying */
- if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR
- || (PZVAL_IS_REF(key) && Z_REFCOUNT_P(key) > 0)
- ) {
- zval *copy;
+ if (UNEXPECTED(var_ptr == NULL)) {
+ zend_throw_error(NULL, "Cannot use assign-op operators with overloaded objects nor string offsets");
- ALLOC_ZVAL(copy);
- INIT_PZVAL_COPY(copy, key);
+ FREE_OP(free_op_data1);
- /* Temporary variables don't need ctor copying */
- if (!0) {
- zval_copy_ctor(copy);
- }
+ HANDLE_EXCEPTION();
+ }
- generator->key = copy;
+ if (UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
} else {
- Z_ADDREF_P(key);
- generator->key = key;
- }
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
- if (Z_TYPE_P(generator->key) == IS_LONG
- && Z_LVAL_P(generator->key) > generator->largest_used_integer_key
- ) {
- generator->largest_used_integer_key = Z_LVAL_P(generator->key);
+ binary_op(var_ptr, var_ptr, value);
+
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+ }
}
+ } while (0);
- zval_ptr_dtor_nogc(&free_op2.var);
- } else {
- /* If no key was specified we use auto-increment keys */
- generator->largest_used_integer_key++;
+ FREE_OP(free_op_data1);
- ALLOC_INIT_ZVAL(generator->key);
- ZVAL_LONG(generator->key, generator->largest_used_integer_key);
- }
-
- if (RETURN_VALUE_USED(opline)) {
- /* If the return value of yield is used set the send
- * target and initialize it to NULL */
- generator->send_target = &EX_T(opline->result.var).var.ptr;
- Z_ADDREF(EG(uninitialized_zval));
- EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
- } else {
- generator->send_target = NULL;
- }
-
- /* We increment to the next op, so we are at the correct position when the
- * generator is resumed. */
- ZEND_VM_INC_OPCODE();
-
- /* The GOTO VM uses a local opline variable. We need to set the opline
- * variable in execute_data so we don't resume at an old position. */
- SAVE_OPLINE();
-
- ZEND_VM_RETURN();
+ ZEND_VM_NEXT_OPCODE_EX(1, 2);
}
-static int ZEND_FASTCALL ZEND_POW_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || (IS_CONST != IS_UNUSED)
USE_OPLINE
- zend_free_op free_op1, free_op2;
- SAVE_OPLINE();
- pow_function(&EX_T(opline->result.var).tmp_var,
- _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC),
- _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2 TSRMLS_CC) TSRMLS_CC);
- zval_ptr_dtor_nogc(&free_op1.var);
- zval_ptr_dtor_nogc(&free_op2.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_CONST(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_binary_assign_op_helper_SPEC_VAR_VAR(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+#if 0 || (IS_CONST != IS_UNUSED)
+ USE_OPLINE
+
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_CONST(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_UNUSED(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || (IS_CONST != IS_UNUSED)
USE_OPLINE
- zend_free_op free_op1, free_op_data1;
- zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
- zval *object;
- zval *property = NULL;
- zval *value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- int have_get_ptr = 0;
- if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_CONST(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-
- make_real_object(object_ptr TSRMLS_CC);
- object = *object_ptr;
-
- if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to assign property of non-object");
-
- FREE_OP(free_op_data1);
-
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
- }
- } else {
- /* here we are sure we are dealing with an object */
- if (0) {
- MAKE_REAL_ZVAL_PTR(property);
- }
-
- /* here property is a string */
- if (opline->extended_value == ZEND_ASSIGN_OBJ
- && Z_OBJ_HT_P(object)->get_property_ptr_ptr) {
- zval **zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_UNUSED == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- if (zptr != NULL) { /* NULL means no success in getting PTR */
- have_get_ptr = 1;
- if (UNEXPECTED(*zptr == &EG(error_zval))) {
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
- }
- } else {
- SEPARATE_ZVAL_IF_NOT_REF(zptr);
-
- binary_op(*zptr, *zptr, value TSRMLS_CC);
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(*zptr);
- EX_T(opline->result.var).var.ptr = *zptr;
- }
- }
- }
- }
-
- if (!have_get_ptr) {
- zval *z = NULL;
-
- Z_ADDREF_P(object);
- if (opline->extended_value == ZEND_ASSIGN_OBJ) {
- if (Z_OBJ_HT_P(object)->read_property) {
- z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_UNUSED == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- }
- } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
- if (Z_OBJ_HT_P(object)->read_dimension) {
- z = Z_OBJ_HT_P(object)->read_dimension(object, property, BP_VAR_R TSRMLS_CC);
- }
- }
- if (z) {
- if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
- zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
-
- if (Z_REFCOUNT_P(z) == 0) {
- GC_REMOVE_ZVAL_FROM_BUFFER(z);
- zval_dtor(z);
- FREE_ZVAL(z);
- }
- z = value;
- }
- Z_ADDREF_P(z);
- SEPARATE_ZVAL_IF_NOT_REF(&z);
- binary_op(z, z, value TSRMLS_CC);
- if (opline->extended_value == ZEND_ASSIGN_OBJ) {
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_UNUSED == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
- Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
- }
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(z);
- EX_T(opline->result.var).var.ptr = z;
- }
- zval_ptr_dtor(&z);
- } else {
- zend_error(E_WARNING, "Attempt to assign property of non-object");
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
- }
- }
- zval_ptr_dtor(&object);
- }
-
- if (0) {
- zval_ptr_dtor(&property);
- } else {
-
- }
- FREE_OP(free_op_data1);
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- /* assign_obj has two opcodes! */
- CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_UNUSED(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || (IS_CONST != IS_UNUSED)
USE_OPLINE
- zend_free_op free_op1, free_op_data2, free_op_data1;
- zval **var_ptr;
- zval *value;
-
- SAVE_OPLINE();
- switch (opline->extended_value) {
- case ZEND_ASSIGN_OBJ:
- return zend_binary_assign_op_obj_helper_SPEC_VAR_UNUSED(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- break;
- case ZEND_ASSIGN_DIM: {
- zval **container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
-
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- } else if (UNEXPECTED(Z_TYPE_PP(container) == IS_OBJECT)) {
- if (IS_VAR == IS_VAR && !(free_op1.var != NULL)) {
- Z_ADDREF_PP(container); /* undo the effect of get_obj_zval_ptr_ptr() */
- }
- return zend_binary_assign_op_obj_helper_SPEC_VAR_UNUSED(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else {
- zval *dim = NULL;
- zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), container, dim, IS_UNUSED, BP_VAR_RW TSRMLS_CC);
- value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- var_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, execute_data, &free_op_data2 TSRMLS_CC);
- }
- }
- break;
- default:
- value = NULL;
- var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
- /* do nothing */
- break;
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_CONST(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-
- if (UNEXPECTED(var_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- if (UNEXPECTED(*var_ptr == &EG(error_zval))) {
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
- }
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || (IS_CONST != IS_UNUSED)
+ USE_OPLINE
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- CHECK_EXCEPTION();
- if (opline->extended_value == ZEND_ASSIGN_DIM) {
- ZEND_VM_INC_OPCODE();
- }
- ZEND_VM_NEXT_OPCODE();
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_CONST(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-
- SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
-
- if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
- && Z_OBJ_HANDLER_PP(var_ptr, get)
- && Z_OBJ_HANDLER_PP(var_ptr, set)) {
- /* proxy object */
- zval *objval = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
- Z_ADDREF_P(objval);
- binary_op(objval, objval, value TSRMLS_CC);
- Z_OBJ_HANDLER_PP(var_ptr, set)(var_ptr, objval TSRMLS_CC);
- zval_ptr_dtor(&objval);
- } else {
- binary_op(*var_ptr, *var_ptr, value TSRMLS_CC);
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(*var_ptr);
- EX_T(opline->result.var).var.ptr = *var_ptr;
- }
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || (IS_CONST != IS_UNUSED)
+ USE_OPLINE
- if (opline->extended_value == ZEND_ASSIGN_DIM) {
- FREE_OP(free_op_data1);
- FREE_OP_VAR_PTR(free_op_data2);
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
- } else {
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- CHECK_EXCEPTION();
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_CONST(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
- ZEND_VM_NEXT_OPCODE();
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_binary_assign_op_helper_SPEC_VAR_UNUSED(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+#if 0 || (IS_CONST != IS_UNUSED)
+ USE_OPLINE
-static int ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_binary_assign_op_helper_SPEC_VAR_UNUSED(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_CONST(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_binary_assign_op_helper_SPEC_VAR_UNUSED(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+#if 0 || (IS_CONST != IS_UNUSED)
+ USE_OPLINE
-static int ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_binary_assign_op_helper_SPEC_VAR_UNUSED(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_CONST(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_binary_assign_op_helper_SPEC_VAR_UNUSED(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+#if 0 || (IS_CONST != IS_UNUSED)
+ USE_OPLINE
-static int ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_binary_assign_op_helper_SPEC_VAR_UNUSED(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_CONST(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_binary_assign_op_helper_SPEC_VAR_UNUSED(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+#if 0 || (IS_CONST != IS_UNUSED)
+ USE_OPLINE
-static int ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_binary_assign_op_helper_SPEC_VAR_UNUSED(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_CONST(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_binary_assign_op_helper_SPEC_VAR_UNUSED(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+#if 0 || (IS_CONST != IS_UNUSED)
+ USE_OPLINE
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_binary_assign_op_helper_SPEC_VAR_UNUSED(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_CONST(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_binary_assign_op_helper_SPEC_VAR_UNUSED(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+#if 0 || (IS_CONST != IS_UNUSED)
+ USE_OPLINE
+
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_CONST(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_VAR_UNUSED(int type, ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_CONST(int inc ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *varname;
- zval **retval;
- zval tmp_varname;
- HashTable *target_symbol_table;
- ulong hash_value;
+
+ zval *object;
+ zval *property;
+ zval *zptr;
SAVE_OPLINE();
- varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
+ object = _get_obj_zval_ptr_unused(execute_data);
+
+ if (IS_UNUSED == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
- if (IS_VAR != IS_CONST && UNEXPECTED(Z_TYPE_P(varname) != IS_STRING)) {
- ZVAL_COPY_VALUE(&tmp_varname, varname);
- zval_copy_ctor(&tmp_varname);
- Z_SET_REFCOUNT(tmp_varname, 1);
- Z_UNSET_ISREF(tmp_varname);
- convert_to_string(&tmp_varname);
- varname = &tmp_varname;
+ HANDLE_EXCEPTION();
}
- if (IS_UNUSED != IS_UNUSED) {
- zend_class_entry *ce;
+ property = EX_CONSTANT(opline->op2);
- if (IS_UNUSED == IS_CONST) {
- if (CACHED_PTR(opline->op2.literal->cache_slot)) {
- ce = CACHED_PTR(opline->op2.literal->cache_slot);
- } else {
- ce = zend_fetch_class_by_name(Z_STRVAL_P(opline->op2.zv), Z_STRLEN_P(opline->op2.zv), opline->op2.literal + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- if (IS_VAR != IS_CONST && varname == &tmp_varname) {
- zval_dtor(&tmp_varname);
- }
- zval_ptr_dtor_nogc(&free_op1.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
- CACHE_PTR(opline->op2.literal->cache_slot, ce);
- }
- } else {
- ce = EX_T(opline->op2.var).class_entry;
- }
- retval = zend_std_get_static_property(ce, Z_STRVAL_P(varname), Z_STRLEN_P(varname), 0, ((IS_VAR == IS_CONST) ? opline->op1.literal : NULL) TSRMLS_CC);
- zval_ptr_dtor_nogc(&free_op1.var);
- } else {
- target_symbol_table = zend_get_target_symbol_table(opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-/*
- if (!target_symbol_table) {
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-*/
- if (IS_VAR == IS_CONST) {
- hash_value = Z_HASH_P(varname);
- } else {
- hash_value = str_hash(Z_STRVAL_P(varname), Z_STRLEN_P(varname));
- }
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot increment/decrement overloaded objects nor string offsets");
- if (zend_hash_quick_find(target_symbol_table, Z_STRVAL_P(varname), Z_STRLEN_P(varname)+1, hash_value, (void **) &retval) == FAILURE) {
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_UNSET:
- zend_error(E_NOTICE,"Undefined variable: %s", Z_STRVAL_P(varname));
- /* break missing intentionally */
- case BP_VAR_IS:
- retval = &EG(uninitialized_zval_ptr);
- break;
- case BP_VAR_RW:
- zend_error(E_NOTICE,"Undefined variable: %s", Z_STRVAL_P(varname));
- /* break missing intentionally */
- case BP_VAR_W:
- Z_ADDREF_P(&EG(uninitialized_zval));
- zend_hash_quick_update(target_symbol_table, Z_STRVAL_P(varname), Z_STRLEN_P(varname)+1, hash_value, &EG(uninitialized_zval_ptr), sizeof(zval *), (void **) &retval);
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
- }
- }
- switch (opline->extended_value & ZEND_FETCH_TYPE_MASK) {
- case ZEND_FETCH_GLOBAL:
- if (IS_VAR != IS_TMP_VAR) {
- zval_ptr_dtor_nogc(&free_op1.var);
- }
- break;
- case ZEND_FETCH_LOCAL:
- zval_ptr_dtor_nogc(&free_op1.var);
- break;
- case ZEND_FETCH_STATIC:
- zval_update_constant(retval, 1 TSRMLS_CC);
- break;
- case ZEND_FETCH_GLOBAL_LOCK:
- if (IS_VAR == IS_VAR && !free_op1.var) {
- PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
+ HANDLE_EXCEPTION();
+ }
+
+ do {
+ if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
}
break;
+ }
}
- }
-
- if (IS_VAR != IS_CONST && varname == &tmp_varname) {
- zval_dtor(&tmp_varname);
- }
- if (opline->extended_value & ZEND_FETCH_MAKE_REF) {
- SEPARATE_ZVAL_TO_MAKE_IS_REF(retval);
- }
- PZVAL_LOCK(*retval);
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_IS:
- EX_T(opline->result.var).var.ptr = *retval;
- break;
- case BP_VAR_UNSET: {
- zend_free_op free_res;
+ /* here we are sure we are dealing with an object */
-
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
-
- if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
- if (inc) {
- fast_long_increment_function(zptr);
- } else {
- fast_long_decrement_function(zptr);
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
-
- if (inc) {
- increment_function(zptr);
++ if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
++ if (inc) {
++ fast_long_increment_function(zptr);
++ } else {
++ fast_long_decrement_function(zptr);
++ }
+ } else {
- decrement_function(zptr);
++ ZVAL_DEREF(zptr);
++ SEPARATE_ZVAL_NOREF(zptr);
+
- PZVAL_UNLOCK(*retval, &free_res);
- if (retval != &EG(uninitialized_zval_ptr)) {
- SEPARATE_ZVAL_IF_NOT_REF(retval);
++ if (inc) {
++ increment_function(zptr);
++ } else {
++ decrement_function(zptr);
++ }
++ }
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_COPY(EX_VAR(opline->result.var), zptr);
+ }
- }
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), zptr);
}
- PZVAL_LOCK(*retval);
- FREE_OP_VAR_PTR(free_res);
+ } else {
+ zend_pre_incdec_overloaded_property(object, property, ((IS_CONST == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), inc, (UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL));
}
- /* break missing intentionally */
- default:
- EX_T(opline->result.var).var.ptr_ptr = retval;
- break;
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ } while (0);
-static int ZEND_FASTCALL ZEND_FETCH_R_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_VAR_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_FETCH_W_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_fetch_var_address_helper_SPEC_VAR_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_TAIL_CALL(zend_pre_incdec_property_helper_SPEC_UNUSED_CONST(1 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL ZEND_FETCH_RW_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_fetch_var_address_helper_SPEC_VAR_UNUSED(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_TAIL_CALL(zend_pre_incdec_property_helper_SPEC_UNUSED_CONST(0 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL ZEND_FETCH_FUNC_ARG_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_CONST(int inc ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
- return zend_fetch_var_address_helper_SPEC_VAR_UNUSED(zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC) ? BP_VAR_W : BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ zval *object;
+ zval *property;
+ zval *zptr;
-static int ZEND_FASTCALL ZEND_FETCH_UNSET_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_VAR_UNUSED(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ SAVE_OPLINE();
+ object = _get_obj_zval_ptr_unused(execute_data);
-static int ZEND_FASTCALL ZEND_FETCH_IS_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_VAR_UNUSED(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ if (IS_UNUSED == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
-static int ZEND_FASTCALL ZEND_FETCH_DIM_W_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval **container;
+ HANDLE_EXCEPTION();
+ }
- SAVE_OPLINE();
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
+ property = EX_CONSTANT(opline->op2);
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- zend_fetch_dimension_address(&EX_T(opline->result.var), container, NULL, IS_UNUSED, BP_VAR_W TSRMLS_CC);
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot increment/decrement overloaded objects nor string offsets");
- if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
- EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
+ HANDLE_EXCEPTION();
}
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
-
- /* We are going to assign the result by reference */
- if (UNEXPECTED(opline->extended_value != 0)) {
- zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
- if (retval_ptr) {
- Z_DELREF_PP(retval_ptr);
- SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
- Z_ADDREF_PP(retval_ptr);
+ do {
+ if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ break;
+ }
}
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ /* here we are sure we are dealing with an object */
-static int ZEND_FASTCALL ZEND_FETCH_DIM_RW_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval **container;
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
-
- if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
- if (inc) {
- fast_long_increment_function(zptr);
- } else {
- fast_long_decrement_function(zptr);
- }
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
+ } else {
- ZVAL_DEREF(zptr);
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
- zval_opt_copy_ctor(zptr);
- if (inc) {
- increment_function(zptr);
++ if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
++ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
++ if (inc) {
++ fast_long_increment_function(zptr);
++ } else {
++ fast_long_decrement_function(zptr);
++ }
+ } else {
- decrement_function(zptr);
++ ZVAL_DEREF(zptr);
++ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
++ zval_opt_copy_ctor(zptr);
++ if (inc) {
++ increment_function(zptr);
++ } else {
++ decrement_function(zptr);
++ }
+ }
+ }
+ } else {
+ zend_post_incdec_overloaded_property(object, property, ((IS_CONST == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), inc, EX_VAR(opline->result.var));
+ }
+ } while (0);
- SAVE_OPLINE();
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- zend_fetch_dimension_address(&EX_T(opline->result.var), container, NULL, IS_UNUSED, BP_VAR_RW TSRMLS_CC);
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
+}
- if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
- EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
- }
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ ZEND_VM_TAIL_CALL(zend_post_incdec_property_helper_SPEC_UNUSED_CONST(1 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ ZEND_VM_TAIL_CALL(zend_post_incdec_property_helper_SPEC_UNUSED_CONST(0 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+}
+
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
+
+ zval *container;
+
+ zval *offset;
SAVE_OPLINE();
+ container = _get_obj_zval_ptr_unused(execute_data);
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- zval **container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ if (IS_UNUSED == IS_UNUSED && UNEXPECTED(Z_OBJ_P(container) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+
+ HANDLE_EXCEPTION();
+ }
+
+ offset = EX_CONSTANT(opline->op2);
+
+ if (IS_UNUSED == IS_CONST ||
+ (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT))) {
+ if ((IS_UNUSED & (IS_VAR|IS_CV)) && Z_ISREF_P(container)) {
+ container = Z_REFVAL_P(container);
+ if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) {
+ goto fetch_obj_r_no_object;
+ }
+ } else {
+ goto fetch_obj_r_no_object;
}
- zend_fetch_dimension_address(&EX_T(opline->result.var), container, NULL, IS_UNUSED, BP_VAR_W TSRMLS_CC);
- if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
- EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
+ }
+
+ /* here we are sure we are dealing with an object */
+ do {
+ zend_object *zobj = Z_OBJ_P(container);
+ zval *retval;
+
+ if (IS_CONST == IS_CONST &&
+ EXPECTED(zobj->ce == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
+ uint32_t prop_offset = (uint32_t)(intptr_t)CACHED_PTR(Z_CACHE_SLOT_P(offset) + sizeof(void*));
+
+ if (EXPECTED(prop_offset != (uint32_t)ZEND_DYNAMIC_PROPERTY_OFFSET)) {
+ retval = OBJ_PROP(zobj, prop_offset);
+ if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
+ }
+ } else if (EXPECTED(zobj->properties != NULL)) {
+ retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
+ if (EXPECTED(retval)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
+ }
+ }
}
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- } else {
- zval *container;
+ if (UNEXPECTED(zobj->handlers->read_property == NULL)) {
+fetch_obj_r_no_object:
+ zend_error(E_NOTICE, "Trying to get property of non-object");
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ } else {
+ retval = zobj->handlers->read_property(container, offset, BP_VAR_R, ((IS_CONST == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var));
- if (IS_UNUSED == IS_UNUSED) {
- zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
+ if (retval != EX_VAR(opline->result.var)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ }
}
- container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
- zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, NULL, IS_UNUSED, BP_VAR_R TSRMLS_CC);
+ } while (0);
- zval_ptr_dtor_nogc(&free_op1.var);
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_DIM_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_FETCH_OBJ_W_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
}
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_UNSET_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_YIELD_SPEC_UNUSED_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_res;
- zval **container;
- zval *property;
+
+ zend_generator *generator = zend_get_running_generator(execute_data);
SAVE_OPLINE();
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
- property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ if (UNEXPECTED(generator->flags & ZEND_GENERATOR_FORCED_CLOSE)) {
+ zend_throw_error(NULL, "Cannot yield from finally in a force-closed generator");
- if (IS_VAR == IS_CV) {
- if (container != &EG(uninitialized_zval_ptr)) {
- SEPARATE_ZVAL_IF_NOT_REF(container);
- }
- }
- if (0) {
- MAKE_REAL_ZVAL_PTR(property);
- }
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
- zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_UNSET TSRMLS_CC);
- if (0) {
- zval_ptr_dtor(&property);
- } else {
+ HANDLE_EXCEPTION();
}
- if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
- EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
- }
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- PZVAL_UNLOCK(*EX_T(opline->result.var).var.ptr_ptr, &free_res);
- if (EX_T(opline->result.var).var.ptr_ptr != &EG(uninitialized_zval_ptr)) {
- SEPARATE_ZVAL_IF_NOT_REF(EX_T(opline->result.var).var.ptr_ptr);
- }
- PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
- FREE_OP_VAR_PTR(free_res);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ /* Destroy the previously yielded value */
+ zval_ptr_dtor(&generator->value);
-static int ZEND_FASTCALL ZEND_ASSIGN_OBJ_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval **object_ptr;
- zval *property_name;
+ /* Destroy the previously yielded key */
+ zval_ptr_dtor(&generator->key);
- SAVE_OPLINE();
- object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
- property_name = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ /* Set the new yielded value */
+ if (IS_UNUSED != IS_UNUSED) {
- if (0) {
- MAKE_REAL_ZVAL_PTR(property_name);
- }
- if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- if (0) {
- zval_ptr_dtor(&property_name);
- } else {
- }
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- /* assign_obj has two opcodes! */
- CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
-}
+ if (UNEXPECTED(EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE)) {
+ /* Constants and temporary variables aren't yieldable by reference,
+ * but we still allow them with a notice. */
+ if (IS_UNUSED == IS_CONST || IS_UNUSED == IS_TMP_VAR) {
+ zval *value;
-static int ZEND_FASTCALL ZEND_ASSIGN_DIM_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval **object_ptr;
+ zend_error(E_NOTICE, "Only variable references should be yielded by reference");
- SAVE_OPLINE();
- object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
+ value = NULL;
+ ZVAL_COPY_VALUE(&generator->value, value);
+ if (IS_UNUSED == IS_CONST) {
+ if (UNEXPECTED(Z_OPT_COPYABLE(generator->value))) {
+ zval_copy_ctor_func(&generator->value);
+ }
+ }
+ } else {
+ zval *value_ptr = NULL;
- if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- if (Z_TYPE_PP(object_ptr) == IS_OBJECT) {
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+ zend_throw_error(NULL, "Cannot yield string offsets by reference");
- zval *property_name = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ HANDLE_EXCEPTION();
+ }
- if (0) {
- MAKE_REAL_ZVAL_PTR(property_name);
- }
- zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- if (0) {
- zval_ptr_dtor(&property_name);
+ /* If a function call result is yielded and the function did
+ * not return by reference we throw a notice. */
+ if (IS_UNUSED == IS_VAR &&
+ (value_ptr == &EG(uninitialized_zval) ||
+ (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+ !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+ zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+ } else {
+ ZVAL_MAKE_REF(value_ptr);
+ }
+ ZVAL_COPY(&generator->value, value_ptr);
+
+ }
} else {
+ zval *value = NULL;
+
+ /* Consts, temporary variables and references need copying */
+ if (IS_UNUSED == IS_CONST) {
+ ZVAL_COPY_VALUE(&generator->value, value);
+ if (UNEXPECTED(Z_OPT_COPYABLE(generator->value))) {
+ zval_copy_ctor_func(&generator->value);
+ }
+ } else if (IS_UNUSED == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&generator->value, value);
+ } else if ((IS_UNUSED & (IS_VAR|IS_CV)) && Z_ISREF_P(value)) {
+ ZVAL_COPY(&generator->value, Z_REFVAL_P(value));
+ } else {
+ ZVAL_COPY_VALUE(&generator->value, value);
+ if (IS_UNUSED == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+ }
+ }
}
} else {
- zend_free_op free_op_data1, free_op_data2;
- zval *value;
- zval *dim = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
- zval **variable_ptr_ptr;
+ /* If no value was specified yield null */
+ ZVAL_NULL(&generator->value);
+ }
- zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), object_ptr, dim, IS_CV, BP_VAR_W TSRMLS_CC);
+ /* Set the new yielded key */
+ if (IS_UNUSED != IS_UNUSED) {
- value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- variable_ptr_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, execute_data, &free_op_data2 TSRMLS_CC);
- if (UNEXPECTED(variable_ptr_ptr == NULL)) {
- if (zend_assign_to_string_offset(&EX_T((opline+1)->op2.var), value, (opline+1)->op1_type TSRMLS_CC)) {
- if (RETURN_VALUE_USED(opline)) {
- zval *retval;
+ zval *key = NULL;
- ALLOC_ZVAL(retval);
- ZVAL_STRINGL(retval, Z_STRVAL_P(EX_T((opline+1)->op2.var).str_offset.str)+EX_T((opline+1)->op2.var).str_offset.offset, 1, 1);
- INIT_PZVAL(retval);
- EX_T(opline->result.var).var.ptr = retval;
- }
- } else if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
- }
- } else if (UNEXPECTED(*variable_ptr_ptr == &EG(error_zval))) {
- if (IS_TMP_FREE(free_op_data1)) {
- zval_dtor(value);
- }
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+ /* Consts, temporary variables and references need copying */
+ if (IS_UNUSED == IS_CONST) {
+ ZVAL_COPY_VALUE(&generator->key, key);
+ if (UNEXPECTED(Z_OPT_COPYABLE(generator->key))) {
+ zval_copy_ctor_func(&generator->key);
}
+ } else if (IS_UNUSED == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&generator->key, key);
+ } else if ((IS_UNUSED & (IS_VAR|IS_CV)) && Z_ISREF_P(key)) {
+ ZVAL_COPY(&generator->key, Z_REFVAL_P(key));
+
} else {
- if ((opline+1)->op1_type == IS_TMP_VAR) {
- value = zend_assign_tmp_to_variable(variable_ptr_ptr, value TSRMLS_CC);
- } else if ((opline+1)->op1_type == IS_CONST) {
- value = zend_assign_const_to_variable(variable_ptr_ptr, value TSRMLS_CC);
- } else {
- value = zend_assign_to_variable(variable_ptr_ptr, value TSRMLS_CC);
- }
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(value);
- EX_T(opline->result.var).var.ptr = value;
+ ZVAL_COPY_VALUE(&generator->key, key);
+ if (IS_UNUSED == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
}
}
- FREE_OP_VAR_PTR(free_op_data2);
- FREE_OP_IF_VAR(free_op_data1);
+
+ if (Z_TYPE(generator->key) == IS_LONG
+ && Z_LVAL(generator->key) > generator->largest_used_integer_key
+ ) {
+ generator->largest_used_integer_key = Z_LVAL(generator->key);
+ }
+ } else {
+ /* If no key was specified we use auto-increment keys */
+ generator->largest_used_integer_key++;
+ ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
}
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- /* assign_dim has two opcodes! */
- CHECK_EXCEPTION();
+
+ if (RETURN_VALUE_USED(opline)) {
+ /* If the return value of yield is used set the send
+ * target and initialize it to NULL */
+ generator->send_target = EX_VAR(opline->result.var);
+ ZVAL_NULL(generator->send_target);
+ } else {
+ generator->send_target = NULL;
+ }
+
+ /* We increment to the next op, so we are at the correct position when the
+ * generator is resumed. */
ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
+
+ /* The GOTO VM uses a local opline variable. We need to set the opline
+ * variable in execute_data so we don't resume at an old position. */
+ SAVE_OPLINE();
+
+ ZEND_VM_RETURN();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_CV(binary_op_type binary_op ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
- zend_free_op free_op1;
+ zend_free_op free_op_data1;
+ zval *object;
+ zval *property;
zval *value;
- zval **variable_ptr_ptr;
+ zval *zptr;
SAVE_OPLINE();
- value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
- variable_ptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
+ object = _get_obj_zval_ptr_unused(execute_data);
- if (IS_VAR == IS_VAR && UNEXPECTED(variable_ptr_ptr == NULL)) {
- if (zend_assign_to_string_offset(&EX_T(opline->op1.var), value, IS_CV TSRMLS_CC)) {
- if (RETURN_VALUE_USED(opline)) {
- zval *retval;
+ if (IS_UNUSED == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
+
+ HANDLE_EXCEPTION();
+ }
+
+ property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var);
+
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot use string offset as an object");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
+
+ HANDLE_EXCEPTION();
+ }
+
+ do {
+ value = get_zval_ptr_r((opline+1)->op1_type, (opline+1)->op1, execute_data, &free_op_data1);
- ALLOC_ZVAL(retval);
- ZVAL_STRINGL(retval, Z_STRVAL_P(EX_T(opline->op1.var).str_offset.str)+EX_T(opline->op1.var).str_offset.offset, 1, 1);
- INIT_PZVAL(retval);
- EX_T(opline->result.var).var.ptr = retval;
+ if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to assign property of non-object");
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ break;
}
- } else if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
- }
- } else if (IS_VAR == IS_VAR && UNEXPECTED(*variable_ptr_ptr == &EG(error_zval))) {
- if (0) {
- zval_dtor(value);
}
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
- }
- } else {
- if (IS_CV == IS_TMP_VAR) {
- value = zend_assign_tmp_to_variable(variable_ptr_ptr, value TSRMLS_CC);
- } else if (IS_CV == IS_CONST) {
- value = zend_assign_const_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+
+ /* here we are sure we are dealing with an object */
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CV == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
++ }
++ } else {
++ ZVAL_DEREF(zptr);
++ SEPARATE_ZVAL_NOREF(zptr);
+
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
-
- binary_op(zptr, zptr, value);
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), zptr);
++ binary_op(zptr, zptr, value);
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_COPY(EX_VAR(opline->result.var), zptr);
++ }
+ }
} else {
- value = zend_assign_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+ zend_assign_op_overloaded_property(object, property, ((IS_CV == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), value, binary_op, (UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL));
}
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(value);
- EX_T(opline->result.var).var.ptr = value;
- }
- }
+ } while (0);
- if (IS_VAR == IS_VAR && (free_op1.var != NULL)) {
- zval_ptr_dtor_nogc(&value);
- }
+ FREE_OP(free_op_data1);
- /* zend_assign_to_variable() always takes care of op2, never free it! */
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ /* assign_obj has two opcodes! */
+ ZEND_VM_NEXT_OPCODE_EX(1, 2);
}
-static int ZEND_FASTCALL ZEND_ASSIGN_REF_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_UNUSED_CV(binary_op_type binary_op ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval **variable_ptr_ptr;
- zval **value_ptr_ptr;
+ zend_free_op free_op_data1;
+ zval *var_ptr, rv;
+ zval *value, *container, *dim;
SAVE_OPLINE();
- value_ptr_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(execute_data, opline->op2.var TSRMLS_CC);
+ container = _get_obj_zval_ptr_unused(execute_data);
+ if (IS_UNUSED == IS_UNUSED && UNEXPECTED(Z_OBJ_P(container) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
- if (IS_VAR == IS_VAR && UNEXPECTED(EX_T(opline->op1.var).var.ptr_ptr == &EX_T(opline->op1.var).var.ptr)) {
- zend_error_noreturn(E_ERROR, "Cannot assign by reference to overloaded object");
+ HANDLE_EXCEPTION();
}
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_throw_error(NULL, "Cannot use string offset as an array");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
- if (IS_CV == IS_VAR &&
- value_ptr_ptr &&
- !Z_ISREF_PP(value_ptr_ptr) &&
- opline->extended_value == ZEND_RETURNS_FUNCTION &&
- !EX_T(opline->op2.var).var.fcall_returned_reference) {
- if (free_op2.var == NULL) {
- PZVAL_LOCK(*value_ptr_ptr); /* undo the effect of get_zval_ptr_ptr() */
- }
- zend_error(E_STRICT, "Only variables should be assigned by reference");
- if (UNEXPECTED(EG(exception) != NULL)) {
-
- HANDLE_EXCEPTION();
- }
- return ZEND_ASSIGN_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (IS_CV == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
- PZVAL_LOCK(*value_ptr_ptr);
+ HANDLE_EXCEPTION();
}
- variable_ptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
- if ((IS_CV == IS_VAR && UNEXPECTED(value_ptr_ptr == NULL)) ||
- (IS_VAR == IS_VAR && UNEXPECTED(variable_ptr_ptr == NULL))) {
- zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
- }
- zend_assign_to_variable_reference(variable_ptr_ptr, value_ptr_ptr TSRMLS_CC);
+ dim = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var);
- if (IS_CV == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
- Z_DELREF_PP(variable_ptr_ptr);
- }
+ do {
+ if (IS_UNUSED == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) != IS_ARRAY)) {
+ if (IS_UNUSED != IS_UNUSED) {
+ ZVAL_DEREF(container);
+ }
+ if (IS_UNUSED == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ value = get_zval_ptr_r((opline+1)->op1_type, (opline+1)->op1, execute_data, &free_op_data1);
+ zend_binary_assign_op_obj_dim(container, dim, value, UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL, binary_op);
+ break;
+ }
+ }
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(*variable_ptr_ptr);
- EX_T(opline->result.var).var.ptr = *variable_ptr_ptr;
- }
+ zend_fetch_dimension_address_RW(&rv, container, dim, IS_CV);
+ value = get_zval_ptr_r((opline+1)->op1_type, (opline+1)->op1, execute_data, &free_op_data1);
+ ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+ var_ptr = Z_INDIRECT(rv);
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
+ if (UNEXPECTED(var_ptr == NULL)) {
+ zend_throw_error(NULL, "Cannot use assign-op operators with overloaded objects nor string offsets");
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ FREE_OP(free_op_data1);
-static int ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *function_name;
- char *function_name_strval;
- int function_name_strlen;
- zend_free_op free_op1;
- call_slot *call = EX(call_slots) + opline->result.num;
-
- SAVE_OPLINE();
-
- function_name = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
-
- if (IS_CV != IS_CONST &&
- UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
- if (UNEXPECTED(EG(exception) != NULL)) {
HANDLE_EXCEPTION();
}
- zend_error_noreturn(E_ERROR, "Method name must be a string");
- }
-
- function_name_strval = Z_STRVAL_P(function_name);
- function_name_strlen = Z_STRLEN_P(function_name);
-
- call->object = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
-
- if (EXPECTED(call->object != NULL) &&
- EXPECTED(Z_TYPE_P(call->object) == IS_OBJECT)) {
- call->called_scope = Z_OBJCE_P(call->object);
-
- if (IS_CV != IS_CONST ||
- (call->fbc = CACHED_POLYMORPHIC_PTR(opline->op2.literal->cache_slot, call->called_scope)) == NULL) {
- zval *object = call->object;
- if (UNEXPECTED(Z_OBJ_HT_P(call->object)->get_method == NULL)) {
- zend_error_noreturn(E_ERROR, "Object does not support method calls");
+ if (UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
}
+ } else {
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
- /* First, locate the function. */
- call->fbc = Z_OBJ_HT_P(call->object)->get_method(&call->object, function_name_strval, function_name_strlen, ((IS_CV == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
- if (UNEXPECTED(call->fbc == NULL)) {
- zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", Z_OBJ_CLASS_NAME_P(call->object), function_name_strval);
- }
- if (IS_CV == IS_CONST &&
- EXPECTED(call->fbc->type <= ZEND_USER_FUNCTION) &&
- EXPECTED((call->fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
- EXPECTED(call->object == object)) {
- CACHE_POLYMORPHIC_PTR(opline->op2.literal->cache_slot, call->called_scope, call->fbc);
- }
- }
- } else {
- if (UNEXPECTED(EG(exception) != NULL)) {
+ binary_op(var_ptr, var_ptr, value);
- HANDLE_EXCEPTION();
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+ }
}
- zend_error_noreturn(E_ERROR, "Call to a member function %s() on %s", function_name_strval, zend_get_type_by_const(Z_TYPE_P(call->object)));
- }
+ } while (0);
- if ((call->fbc->common.fn_flags & ZEND_ACC_STATIC) != 0) {
- call->object = NULL;
- } else {
- if (!PZVAL_IS_REF(call->object)) {
- Z_ADDREF_P(call->object); /* For $this pointer */
- } else {
- zval *this_ptr;
- ALLOC_ZVAL(this_ptr);
- INIT_PZVAL_COPY(this_ptr, call->object);
- zval_copy_ctor(this_ptr);
- call->object = this_ptr;
- }
- }
+ FREE_OP(free_op_data1);
- call->num_additional_args = 0;
- call->is_ctor_call = 0;
- EX(call) = call;
+ ZEND_VM_NEXT_OPCODE_EX(1, 2);
+}
- zval_ptr_dtor_nogc(&free_op1.var);
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || (IS_CV != IS_UNUSED)
+ USE_OPLINE
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_CV(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CV(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_CV(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CV(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || (IS_CV != IS_UNUSED)
USE_OPLINE
- zval *function_name;
- zend_class_entry *ce;
- call_slot *call = EX(call_slots) + opline->result.num;
- SAVE_OPLINE();
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_CV(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CV(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_CV(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CV(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- if (IS_VAR == IS_CONST) {
- /* no function found. try a static method in class */
- if (CACHED_PTR(opline->op1.literal->cache_slot)) {
- ce = CACHED_PTR(opline->op1.literal->cache_slot);
- } else {
- ce = zend_fetch_class_by_name(Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), opline->op1.literal + 1, opline->extended_value TSRMLS_CC);
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- if (UNEXPECTED(ce == NULL)) {
- zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
- }
- CACHE_PTR(opline->op1.literal->cache_slot, ce);
- }
- call->called_scope = ce;
- } else {
- ce = EX_T(opline->op1.var).class_entry;
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || (IS_CV != IS_UNUSED)
+ USE_OPLINE
- if (opline->extended_value == ZEND_FETCH_CLASS_PARENT || opline->extended_value == ZEND_FETCH_CLASS_SELF) {
- call->called_scope = EG(called_scope);
- } else {
- call->called_scope = ce;
- }
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_CV(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CV(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_CV(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CV(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- if (IS_VAR == IS_CONST &&
- IS_CV == IS_CONST &&
- CACHED_PTR(opline->op2.literal->cache_slot)) {
- call->fbc = CACHED_PTR(opline->op2.literal->cache_slot);
- } else if (IS_VAR != IS_CONST &&
- IS_CV == IS_CONST &&
- (call->fbc = CACHED_POLYMORPHIC_PTR(opline->op2.literal->cache_slot, ce))) {
- /* do nothing */
- } else if (IS_CV != IS_UNUSED) {
- char *function_name_strval = NULL;
- int function_name_strlen = 0;
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || (IS_CV != IS_UNUSED)
+ USE_OPLINE
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_CV(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CV(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_CV(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CV(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- if (IS_CV == IS_CONST) {
- function_name_strval = Z_STRVAL_P(opline->op2.zv);
- function_name_strlen = Z_STRLEN_P(opline->op2.zv);
- } else {
- function_name = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || (IS_CV != IS_UNUSED)
+ USE_OPLINE
- if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- zend_error_noreturn(E_ERROR, "Function name must be a string");
- } else {
- function_name_strval = Z_STRVAL_P(function_name);
- function_name_strlen = Z_STRLEN_P(function_name);
- }
- }
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_CV(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CV(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_CV(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CV(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- if (function_name_strval) {
- if (ce->get_static_method) {
- call->fbc = ce->get_static_method(ce, function_name_strval, function_name_strlen TSRMLS_CC);
- } else {
- call->fbc = zend_std_get_static_method(ce, function_name_strval, function_name_strlen, ((IS_CV == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
- }
- if (UNEXPECTED(call->fbc == NULL)) {
- zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name, function_name_strval);
- }
- if (IS_CV == IS_CONST &&
- EXPECTED(call->fbc->type <= ZEND_USER_FUNCTION) &&
- EXPECTED((call->fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0)) {
- if (IS_VAR == IS_CONST) {
- CACHE_PTR(opline->op2.literal->cache_slot, call->fbc);
- } else {
- CACHE_POLYMORPHIC_PTR(opline->op2.literal->cache_slot, ce, call->fbc);
- }
- }
- }
- if (IS_CV != IS_CONST) {
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || (IS_CV != IS_UNUSED)
+ USE_OPLINE
- }
- } else {
- if (UNEXPECTED(ce->constructor == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot call constructor");
- }
- if (EG(This) && Z_OBJCE_P(EG(This)) != ce->constructor->common.scope && (ce->constructor->common.fn_flags & ZEND_ACC_PRIVATE)) {
- zend_error_noreturn(E_ERROR, "Cannot call private %s::__construct()", ce->name);
- }
- call->fbc = ce->constructor;
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_CV(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-
- if (call->fbc->common.fn_flags & ZEND_ACC_STATIC) {
- call->object = NULL;
- } else {
- if (EG(This) &&
- Z_OBJ_HT_P(EG(This))->get_class_entry &&
- !instanceof_function(Z_OBJCE_P(EG(This)), ce TSRMLS_CC)) {
- /* We are calling method of the other (incompatible) class,
- but passing $this. This is done for compatibility with php-4. */
- if (call->fbc->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
- zend_error(E_DEPRECATED, "Non-static method %s::%s() should not be called statically, assuming $this from incompatible context", call->fbc->common.scope->name, call->fbc->common.function_name);
- } else {
- /* An internal function assumes $this is present and won't check that. So PHP would crash by allowing the call. */
- zend_error_noreturn(E_ERROR, "Non-static method %s::%s() cannot be called statically, assuming $this from incompatible context", call->fbc->common.scope->name, call->fbc->common.function_name);
- }
- }
- if ((call->object = EG(This))) {
- Z_ADDREF_P(call->object);
- call->called_scope = Z_OBJCE_P(call->object);
- }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CV(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_CV(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CV(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- call->num_additional_args = 0;
- call->is_ctor_call = 0;
- EX(call) = call;
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || (IS_CV != IS_UNUSED)
+ USE_OPLINE
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_CV(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CV(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_CV(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CV(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_CASE_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || (IS_CV != IS_UNUSED)
USE_OPLINE
- zend_free_op free_op1;
-
- SAVE_OPLINE();
- is_equal_function(&EX_T(opline->result.var).tmp_var,
- _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC),
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_CV(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CV(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_CV(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CV(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || (IS_CV != IS_UNUSED)
USE_OPLINE
- zend_free_op free_op1;
- zval *expr_ptr;
-
- SAVE_OPLINE();
- if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && opline->extended_value) {
- zval **expr_ptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
- if (IS_VAR == IS_VAR && UNEXPECTED(expr_ptr_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
- }
- SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
- expr_ptr = *expr_ptr_ptr;
- Z_ADDREF_P(expr_ptr);
- } else {
- expr_ptr=_get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
- if (0) { /* temporary variable */
- zval *new_expr;
-
- ALLOC_ZVAL(new_expr);
- INIT_PZVAL_COPY(new_expr, expr_ptr);
- expr_ptr = new_expr;
- } else if (IS_VAR == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
- zval *new_expr;
-
- ALLOC_ZVAL(new_expr);
- INIT_PZVAL_COPY(new_expr, expr_ptr);
- expr_ptr = new_expr;
- zendi_zval_copy_ctor(*expr_ptr);
- zval_ptr_dtor_nogc(&free_op1.var);
- } else if (IS_VAR == IS_CV) {
- Z_ADDREF_P(expr_ptr);
- }
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_CV(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CV(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_CV(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CV(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- if (IS_CV != IS_UNUSED) {
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || (IS_CV != IS_UNUSED)
+ USE_OPLINE
- zval *offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
- ulong hval;
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_CV(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CV(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_CV(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CV(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- goto num_index;
- case IS_LONG:
- case IS_BOOL:
- hval = Z_LVAL_P(offset);
-num_index:
- zend_hash_index_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), hval, &expr_ptr, sizeof(zval *), NULL);
- break;
- case IS_STRING:
- if (IS_CV == IS_CONST) {
- hval = Z_HASH_P(offset);
- } else {
- ZEND_HANDLE_NUMERIC_EX(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, goto num_index);
- hval = str_hash(Z_STRVAL_P(offset), Z_STRLEN_P(offset));
- }
- zend_hash_quick_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
- break;
- case IS_NULL:
- zend_hash_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
- break;
- default:
- zend_error(E_WARNING, "Illegal offset type");
- zval_ptr_dtor(&expr_ptr);
- /* do nothing */
- break;
- }
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || (IS_CV != IS_UNUSED)
+ USE_OPLINE
- } else {
- zend_hash_next_index_insert(Z_ARRVAL(EX_T(opline->result.var).tmp_var), &expr_ptr, sizeof(zval *), NULL);
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_CV(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
- if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && opline->extended_value) {
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CV(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_CV(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CV(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || (IS_CV != IS_UNUSED)
USE_OPLINE
- array_init(&EX_T(opline->result.var).tmp_var);
- if (IS_VAR == IS_UNUSED) {
- ZEND_VM_NEXT_OPCODE();
-#if 0 || IS_VAR != IS_UNUSED
- } else {
- return ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-#endif
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_CV(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CV(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_CV(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_CV(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_UNSET_DIM_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_CV(int inc ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
- zend_free_op free_op1;
- zval **container;
- zval *offset;
- ulong hval;
+
+ zval *object;
+ zval *property;
+ zval *zptr;
SAVE_OPLINE();
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
- if (IS_VAR == IS_CV && container != &EG(uninitialized_zval_ptr)) {
- SEPARATE_ZVAL_IF_NOT_REF(container);
+ object = _get_obj_zval_ptr_unused(execute_data);
+
+ if (IS_UNUSED == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+
+ HANDLE_EXCEPTION();
}
- offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
- if (IS_VAR != IS_VAR || container) {
- switch (Z_TYPE_PP(container)) {
- case IS_ARRAY: {
- HashTable *ht = Z_ARRVAL_PP(container);
+ property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var);
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- zend_hash_index_del(ht, hval);
- break;
- case IS_RESOURCE:
- case IS_BOOL:
- case IS_LONG:
- hval = Z_LVAL_P(offset);
- zend_hash_index_del(ht, hval);
- break;
- case IS_STRING:
- if (IS_CV == IS_CV || IS_CV == IS_VAR) {
- Z_ADDREF_P(offset);
- }
- if (IS_CV == IS_CONST) {
- hval = Z_HASH_P(offset);
- } else {
- ZEND_HANDLE_NUMERIC_EX(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, goto num_index_dim);
- hval = str_hash(Z_STRVAL_P(offset), Z_STRLEN_P(offset));
- }
- if (ht == &EG(symbol_table)) {
- zend_delete_global_variable_ex(offset->value.str.val, offset->value.str.len, hval TSRMLS_CC);
- } else {
- zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval);
- }
- if (IS_CV == IS_CV || IS_CV == IS_VAR) {
- zval_ptr_dtor(&offset);
- }
- break;
-num_index_dim:
- zend_hash_index_del(ht, hval);
- if (IS_CV == IS_CV || IS_CV == IS_VAR) {
- zval_ptr_dtor(&offset);
- }
- break;
- case IS_NULL:
- zend_hash_del(ht, "", sizeof(""));
- break;
- default:
- zend_error(E_WARNING, "Illegal offset type in unset");
- break;
- }
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot increment/decrement overloaded objects nor string offsets");
+
+ HANDLE_EXCEPTION();
+ }
+ do {
+ if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
break;
}
- case IS_OBJECT:
- if (UNEXPECTED(Z_OBJ_HT_P(*container)->unset_dimension == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use object as array");
- }
- if (0) {
- MAKE_REAL_ZVAL_PTR(offset);
+ }
+
+ /* here we are sure we are dealing with an object */
-
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CV == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
-
- if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
- if (inc) {
- fast_long_increment_function(zptr);
- } else {
- fast_long_decrement_function(zptr);
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
}
- Z_OBJ_HT_P(*container)->unset_dimension(*container, offset TSRMLS_CC);
- if (0) {
- zval_ptr_dtor(&offset);
+ } else {
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
-
- if (inc) {
- increment_function(zptr);
++ if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
++ if (inc) {
++ fast_long_increment_function(zptr);
++ } else {
++ fast_long_decrement_function(zptr);
++ }
} else {
- decrement_function(zptr);
++ ZVAL_DEREF(zptr);
++ SEPARATE_ZVAL_NOREF(zptr);
+
++ if (inc) {
++ increment_function(zptr);
++ } else {
++ decrement_function(zptr);
++ }
+ }
- break;
- case IS_STRING:
- zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
- ZEND_VM_CONTINUE(); /* bailed out before */
- default:
-
- break;
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_COPY(EX_VAR(opline->result.var), zptr);
+ }
- }
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), zptr);
+ }
+ } else {
+ zend_pre_incdec_overloaded_property(object, property, ((IS_CV == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), inc, (UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL));
}
- } else {
+ } while (0);
- }
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
+}
+
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ ZEND_VM_TAIL_CALL(zend_pre_incdec_property_helper_SPEC_UNUSED_CV(1 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL ZEND_UNSET_OBJ_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ ZEND_VM_TAIL_CALL(zend_pre_incdec_property_helper_SPEC_UNUSED_CV(0 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+}
+
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_CV(int inc ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
- zend_free_op free_op1;
- zval **container;
- zval *offset;
+
+ zval *object;
+ zval *property;
+ zval *zptr;
SAVE_OPLINE();
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
- offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ object = _get_obj_zval_ptr_unused(execute_data);
- if (IS_VAR != IS_VAR || container) {
- if (IS_VAR == IS_CV && container != &EG(uninitialized_zval_ptr)) {
- SEPARATE_ZVAL_IF_NOT_REF(container);
- }
- if (Z_TYPE_PP(container) == IS_OBJECT) {
- if (0) {
- MAKE_REAL_ZVAL_PTR(offset);
- }
- if (Z_OBJ_HT_P(*container)->unset_property) {
- Z_OBJ_HT_P(*container)->unset_property(*container, offset, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to unset property of non-object");
- }
- if (0) {
- zval_ptr_dtor(&offset);
- } else {
+ if (IS_UNUSED == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
- }
- } else {
+ HANDLE_EXCEPTION();
+ }
- }
- } else {
+ property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var);
- }
- if (free_op1.var) {zval_ptr_dtor_nogc(&free_op1.var);};
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot increment/decrement overloaded objects nor string offsets");
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ HANDLE_EXCEPTION();
+ }
-static int ZEND_FASTCALL zend_isset_isempty_dim_prop_obj_handler_SPEC_VAR_CV(int prop_dim, ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *container;
- zval **value = NULL;
- int result = 0;
- ulong hval;
- zval *offset;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1 TSRMLS_CC);
- offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
-
- if (Z_TYPE_P(container) == IS_ARRAY && !prop_dim) {
- HashTable *ht;
- int isset = 0;
-
- ht = Z_ARRVAL_P(container);
-
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- goto num_index_prop;
- case IS_RESOURCE:
- case IS_BOOL:
- case IS_LONG:
- hval = Z_LVAL_P(offset);
-num_index_prop:
- if (zend_hash_index_find(ht, hval, (void **) &value) == SUCCESS) {
- isset = 1;
- }
- break;
- case IS_STRING:
- if (IS_CV == IS_CONST) {
- hval = Z_HASH_P(offset);
- } else {
- ZEND_HANDLE_NUMERIC_EX(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, goto num_index_prop);
- hval = str_hash(Z_STRVAL_P(offset), Z_STRLEN_P(offset));
- }
- if (zend_hash_quick_find(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, (void **) &value) == SUCCESS) {
- isset = 1;
- }
- break;
- case IS_NULL:
- if (zend_hash_find(ht, "", sizeof(""), (void **) &value) == SUCCESS) {
- isset = 1;
- }
- break;
- default:
- zend_error(E_WARNING, "Illegal offset type in isset or empty");
+ do {
+ if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ ZVAL_NULL(EX_VAR(opline->result.var));
break;
- }
-
- if (opline->extended_value & ZEND_ISSET) {
- if (isset && Z_TYPE_PP(value) == IS_NULL) {
- result = 0;
- } else {
- result = isset;
- }
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- if (!isset || !i_zend_is_true(*value)) {
- result = 0;
- } else {
- result = 1;
- }
- }
-
- } else if (Z_TYPE_P(container) == IS_OBJECT) {
- if (0) {
- MAKE_REAL_ZVAL_PTR(offset);
- }
- if (prop_dim) {
- if (Z_OBJ_HT_P(container)->has_property) {
- result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISEMPTY) != 0, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to check property of non-object");
- result = 0;
- }
- } else {
- if (Z_OBJ_HT_P(container)->has_dimension) {
- result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISEMPTY) != 0 TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to check element of non-array");
- result = 0;
}
}
- if (0) {
- zval_ptr_dtor(&offset);
- } else {
- }
- } else if (Z_TYPE_P(container) == IS_STRING && !prop_dim) { /* string offsets */
- zval tmp;
+ /* here we are sure we are dealing with an object */
- if (Z_TYPE_P(offset) != IS_LONG) {
- if (Z_TYPE_P(offset) <= IS_BOOL /* simple scalar types */
- || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
- && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
- ZVAL_COPY_VALUE(&tmp, offset);
- zval_copy_ctor(&tmp);
- convert_to_long(&tmp);
- offset = &tmp;
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CV == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
-
- if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
- if (inc) {
- fast_long_increment_function(zptr);
- } else {
- fast_long_decrement_function(zptr);
- }
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
} else {
- ZVAL_DEREF(zptr);
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
- zval_opt_copy_ctor(zptr);
- if (inc) {
- increment_function(zptr);
- /* can not be converted to proper offset, return "not set" */
- result = 0;
- }
- }
- if (Z_TYPE_P(offset) == IS_LONG) {
- if (opline->extended_value & ZEND_ISSET) {
- if (offset->value.lval >= 0 && offset->value.lval < Z_STRLEN_P(container)) {
- result = 1;
- }
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- if (offset->value.lval >= 0 && offset->value.lval < Z_STRLEN_P(container) && Z_STRVAL_P(container)[offset->value.lval] != '0') {
- result = 1;
++ if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
++ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
++ if (inc) {
++ fast_long_increment_function(zptr);
++ } else {
++ fast_long_decrement_function(zptr);
++ }
+ } else {
- decrement_function(zptr);
++ ZVAL_DEREF(zptr);
++ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
++ zval_opt_copy_ctor(zptr);
++ if (inc) {
++ increment_function(zptr);
++ } else {
++ decrement_function(zptr);
++ }
}
}
+ } else {
+ zend_post_incdec_overloaded_property(object, property, ((IS_CV == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), inc, EX_VAR(opline->result.var));
}
+ } while (0);
- } else {
-
- }
-
- Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
- if (opline->extended_value & ZEND_ISSET) {
- Z_LVAL(EX_T(opline->result.var).tmp_var) = result;
- } else {
- Z_LVAL(EX_T(opline->result.var).tmp_var) = !result;
- }
-
- zval_ptr_dtor_nogc(&free_op1.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_isset_isempty_dim_prop_obj_handler_SPEC_VAR_CV(0, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_TAIL_CALL(zend_post_incdec_property_helper_SPEC_UNUSED_CV(1 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_isset_isempty_dim_prop_obj_handler_SPEC_VAR_CV(1, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_TAIL_CALL(zend_post_incdec_property_helper_SPEC_UNUSED_CV(0 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL ZEND_YIELD_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
{
USE_OPLINE
- zval *container;
-
- zval *offset;
+ zend_generator *generator = zend_get_running_generator(execute_data);
SAVE_OPLINE();
- container = _get_obj_zval_ptr_unused(TSRMLS_C);
- offset = opline->op2.zv;
+ if (UNEXPECTED(generator->flags & ZEND_GENERATOR_FORCED_CLOSE)) {
+ zend_throw_error(NULL, "Cannot yield from finally in a force-closed generator");
- if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
- UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
- } else {
- zval *retval;
+ HANDLE_EXCEPTION();
+ }
- if (0) {
- MAKE_REAL_ZVAL_PTR(offset);
- }
+ /* Destroy the previously yielded value */
+ zval_ptr_dtor(&generator->value);
- /* here we are sure we are dealing with an object */
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+ /* Destroy the previously yielded key */
+ zval_ptr_dtor(&generator->key);
- PZVAL_LOCK(retval);
- EX_T(opline->result.var).var.ptr = retval;
+ /* Set the new yielded value */
+ if (IS_UNUSED != IS_UNUSED) {
- if (0) {
- zval_ptr_dtor(&offset);
- } else {
- }
- }
+ if (UNEXPECTED(EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE)) {
+ /* Constants and temporary variables aren't yieldable by reference,
+ * but we still allow them with a notice. */
+ if (IS_UNUSED == IS_CONST || IS_UNUSED == IS_TMP_VAR) {
+ zval *value;
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ zend_error(E_NOTICE, "Only variable references should be yielded by reference");
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ value = NULL;
+ ZVAL_COPY_VALUE(&generator->value, value);
+ if (IS_UNUSED == IS_CONST) {
+ if (UNEXPECTED(Z_OPT_COPYABLE(generator->value))) {
+ zval_copy_ctor_func(&generator->value);
+ }
+ }
+ } else {
+ zval *value_ptr = NULL;
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- /* Behave like FETCH_OBJ_W */
- zend_free_op free_op1;
- zval *property;
- zval **container;
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+ zend_throw_error(NULL, "Cannot yield string offsets by reference");
- SAVE_OPLINE();
- property = opline->op2.zv;
- container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+ HANDLE_EXCEPTION();
+ }
- if (0) {
- MAKE_REAL_ZVAL_PTR(property);
- }
- if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
- zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
- if (0) {
- zval_ptr_dtor(&property);
+ /* If a function call result is yielded and the function did
+ * not return by reference we throw a notice. */
+ if (IS_UNUSED == IS_VAR &&
+ (value_ptr == &EG(uninitialized_zval) ||
+ (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+ !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+ zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+ } else {
+ ZVAL_MAKE_REF(value_ptr);
+ }
+ ZVAL_COPY(&generator->value, value_ptr);
+
+ }
} else {
+ zval *value = NULL;
- }
- if (IS_UNUSED == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
- EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
- }
+ /* Consts, temporary variables and references need copying */
+ if (IS_UNUSED == IS_CONST) {
+ ZVAL_COPY_VALUE(&generator->value, value);
+ if (UNEXPECTED(Z_OPT_COPYABLE(generator->value))) {
+ zval_copy_ctor_func(&generator->value);
+ }
+ } else if (IS_UNUSED == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&generator->value, value);
+ } else if ((IS_UNUSED & (IS_VAR|IS_CV)) && Z_ISREF_P(value)) {
+ ZVAL_COPY(&generator->value, Z_REFVAL_P(value));
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ } else {
+ ZVAL_COPY_VALUE(&generator->value, value);
+ if (IS_UNUSED == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+ }
+ }
+ }
} else {
- return zend_fetch_property_address_read_helper_SPEC_UNUSED_CONST(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ /* If no value was specified yield null */
+ ZVAL_NULL(&generator->value);
}
-}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1, free_res;
- zval **container;
- zval *property;
+ /* Set the new yielded key */
+ if (IS_CV != IS_UNUSED) {
- SAVE_OPLINE();
- container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
- property = opline->op2.zv;
+ zval *key = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var);
+
+ /* Consts, temporary variables and references need copying */
+ if (IS_CV == IS_CONST) {
+ ZVAL_COPY_VALUE(&generator->key, key);
+ if (UNEXPECTED(Z_OPT_COPYABLE(generator->key))) {
+ zval_copy_ctor_func(&generator->key);
+ }
+ } else if (IS_CV == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&generator->key, key);
+ } else if ((IS_CV & (IS_VAR|IS_CV)) && Z_ISREF_P(key)) {
+ ZVAL_COPY(&generator->key, Z_REFVAL_P(key));
- if (IS_UNUSED == IS_CV) {
- if (container != &EG(uninitialized_zval_ptr)) {
- SEPARATE_ZVAL_IF_NOT_REF(container);
+ } else {
+ ZVAL_COPY_VALUE(&generator->key, key);
+ if (IS_CV == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
+ }
}
- }
- if (0) {
- MAKE_REAL_ZVAL_PTR(property);
- }
- if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
- zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_UNSET TSRMLS_CC);
- if (0) {
- zval_ptr_dtor(&property);
- } else {
- }
- if (IS_UNUSED == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
- EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
+ if (Z_TYPE(generator->key) == IS_LONG
+ && Z_LVAL(generator->key) > generator->largest_used_integer_key
+ ) {
+ generator->largest_used_integer_key = Z_LVAL(generator->key);
+ }
+ } else {
+ /* If no key was specified we use auto-increment keys */
+ generator->largest_used_integer_key++;
+ ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
}
- PZVAL_UNLOCK(*EX_T(opline->result.var).var.ptr_ptr, &free_res);
- if (EX_T(opline->result.var).var.ptr_ptr != &EG(uninitialized_zval_ptr)) {
- SEPARATE_ZVAL_IF_NOT_REF(EX_T(opline->result.var).var.ptr_ptr);
+ if (RETURN_VALUE_USED(opline)) {
+ /* If the return value of yield is used set the send
+ * target and initialize it to NULL */
+ generator->send_target = EX_VAR(opline->result.var);
+ ZVAL_NULL(generator->send_target);
+ } else {
+ generator->send_target = NULL;
}
- PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
- FREE_OP_VAR_PTR(free_res);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval **object_ptr;
- zval *property_name;
+ /* We increment to the next op, so we are at the correct position when the
+ * generator is resumed. */
+ ZEND_VM_INC_OPCODE();
+ /* The GOTO VM uses a local opline variable. We need to set the opline
+ * variable in execute_data so we don't resume at an old position. */
SAVE_OPLINE();
- object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
- property_name = opline->op2.zv;
-
- if (0) {
- MAKE_REAL_ZVAL_PTR(property_name);
- }
- if (IS_UNUSED == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- if (0) {
- zval_ptr_dtor(&property_name);
- } else {
-
- }
- /* assign_obj has two opcodes! */
- CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
+ ZEND_VM_RETURN();
}
-static int ZEND_FASTCALL ZEND_ADD_CHAR_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMPVAR(binary_op_type binary_op ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
- zval *str = &EX_T(opline->result.var).tmp_var;
+ zend_free_op free_op2, free_op_data1;
+ zval *object;
+ zval *property;
+ zval *value;
+ zval *zptr;
SAVE_OPLINE();
+ object = _get_obj_zval_ptr_unused(execute_data);
- if (IS_UNUSED == IS_UNUSED) {
- /* Initialize for erealloc in add_char_to_string */
- Z_STRVAL_P(str) = NULL;
- Z_STRLEN_P(str) = 0;
- Z_TYPE_P(str) = IS_STRING;
-
- INIT_PZVAL(str);
+ if (IS_UNUSED == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
+ zval_ptr_dtor_nogc(EX_VAR(opline->op2.var));
+ HANDLE_EXCEPTION();
}
- add_char_to_string(str, str, opline->op2.zv);
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- /* FREE_OP is missing intentionally here - we're always working on the same temporary variable */
- /*CHECK_EXCEPTION();*/
- ZEND_VM_NEXT_OPCODE();
-}
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot use string offset as an object");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
+ zval_ptr_dtor_nogc(free_op2);
+ HANDLE_EXCEPTION();
+ }
-static int ZEND_FASTCALL ZEND_ADD_STRING_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *str = &EX_T(opline->result.var).tmp_var;
+ do {
+ value = get_zval_ptr_r((opline+1)->op1_type, (opline+1)->op1, execute_data, &free_op_data1);
- SAVE_OPLINE();
+ if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to assign property of non-object");
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ break;
+ }
+ }
- if (IS_UNUSED == IS_UNUSED) {
- /* Initialize for erealloc in add_string_to_string */
- Z_STRVAL_P(str) = NULL;
- Z_STRLEN_P(str) = 0;
- Z_TYPE_P(str) = IS_STRING;
+ /* here we are sure we are dealing with an object */
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
++ }
++ } else {
++ ZVAL_DEREF(zptr);
++ SEPARATE_ZVAL_NOREF(zptr);
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
-
- binary_op(zptr, zptr, value);
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), zptr);
- INIT_PZVAL(str);
- }
++ binary_op(zptr, zptr, value);
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_COPY(EX_VAR(opline->result.var), zptr);
++ }
+ }
+ } else {
+ zend_assign_op_overloaded_property(object, property, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), value, binary_op, (UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL));
+ }
+ } while (0);
- add_string_to_string(str, str, opline->op2.zv);
+ FREE_OP(free_op_data1);
+ zval_ptr_dtor_nogc(free_op2);
- /* FREE_OP is missing intentionally here - we're always working on the same temporary variable */
- /*CHECK_EXCEPTION();*/
- ZEND_VM_NEXT_OPCODE();
+ /* assign_obj has two opcodes! */
+ ZEND_VM_NEXT_OPCODE_EX(1, 2);
}
-static int ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMPVAR(binary_op_type binary_op ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
- zval *function_name;
- char *function_name_strval;
- int function_name_strlen;
-
- call_slot *call = EX(call_slots) + opline->result.num;
+ zend_free_op free_op2, free_op_data1;
+ zval *var_ptr, rv;
+ zval *value, *container, *dim;
SAVE_OPLINE();
+ container = _get_obj_zval_ptr_unused(execute_data);
+ if (IS_UNUSED == IS_UNUSED && UNEXPECTED(Z_OBJ_P(container) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
+ zval_ptr_dtor_nogc(EX_VAR(opline->op2.var));
+ HANDLE_EXCEPTION();
+ }
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_throw_error(NULL, "Cannot use string offset as an array");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
+ zval_ptr_dtor_nogc(EX_VAR(opline->op2.var));
+ HANDLE_EXCEPTION();
+ }
- function_name = opline->op2.zv;
+ dim = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_CONST != IS_CONST &&
- UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
+ do {
+ if (IS_UNUSED == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) != IS_ARRAY)) {
+ if (IS_UNUSED != IS_UNUSED) {
+ ZVAL_DEREF(container);
+ }
+ if (IS_UNUSED == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ value = get_zval_ptr_r((opline+1)->op1_type, (opline+1)->op1, execute_data, &free_op_data1);
+ zend_binary_assign_op_obj_dim(container, dim, value, UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL, binary_op);
+ break;
+ }
}
- zend_error_noreturn(E_ERROR, "Method name must be a string");
- }
-
- function_name_strval = Z_STRVAL_P(function_name);
- function_name_strlen = Z_STRLEN_P(function_name);
- call->object = _get_obj_zval_ptr_unused(TSRMLS_C);
+ zend_fetch_dimension_address_RW(&rv, container, dim, (IS_TMP_VAR|IS_VAR));
+ value = get_zval_ptr_r((opline+1)->op1_type, (opline+1)->op1, execute_data, &free_op_data1);
+ ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+ var_ptr = Z_INDIRECT(rv);
- if (EXPECTED(call->object != NULL) &&
- EXPECTED(Z_TYPE_P(call->object) == IS_OBJECT)) {
- call->called_scope = Z_OBJCE_P(call->object);
+ if (UNEXPECTED(var_ptr == NULL)) {
+ zend_throw_error(NULL, "Cannot use assign-op operators with overloaded objects nor string offsets");
+ zval_ptr_dtor_nogc(free_op2);
+ FREE_OP(free_op_data1);
- if (IS_CONST != IS_CONST ||
- (call->fbc = CACHED_POLYMORPHIC_PTR(opline->op2.literal->cache_slot, call->called_scope)) == NULL) {
- zval *object = call->object;
+ HANDLE_EXCEPTION();
+ }
- if (UNEXPECTED(Z_OBJ_HT_P(call->object)->get_method == NULL)) {
- zend_error_noreturn(E_ERROR, "Object does not support method calls");
+ if (UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
}
+ } else {
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
- /* First, locate the function. */
- call->fbc = Z_OBJ_HT_P(call->object)->get_method(&call->object, function_name_strval, function_name_strlen, ((IS_CONST == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
- if (UNEXPECTED(call->fbc == NULL)) {
- zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", Z_OBJ_CLASS_NAME_P(call->object), function_name_strval);
- }
- if (IS_CONST == IS_CONST &&
- EXPECTED(call->fbc->type <= ZEND_USER_FUNCTION) &&
- EXPECTED((call->fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
- EXPECTED(call->object == object)) {
- CACHE_POLYMORPHIC_PTR(opline->op2.literal->cache_slot, call->called_scope, call->fbc);
+ binary_op(var_ptr, var_ptr, value);
+
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
}
}
- } else {
- if (UNEXPECTED(EG(exception) != NULL)) {
+ } while (0);
- HANDLE_EXCEPTION();
- }
- zend_error_noreturn(E_ERROR, "Call to a member function %s() on %s", function_name_strval, zend_get_type_by_const(Z_TYPE_P(call->object)));
- }
+ zval_ptr_dtor_nogc(free_op2);
+ FREE_OP(free_op_data1);
- if ((call->fbc->common.fn_flags & ZEND_ACC_STATIC) != 0) {
- call->object = NULL;
- } else {
- if (!PZVAL_IS_REF(call->object)) {
- Z_ADDREF_P(call->object); /* For $this pointer */
- } else {
- zval *this_ptr;
- ALLOC_ZVAL(this_ptr);
- INIT_PZVAL_COPY(this_ptr, call->object);
- zval_copy_ctor(this_ptr);
- call->object = this_ptr;
- }
+ ZEND_VM_NEXT_OPCODE_EX(1, 2);
+}
+
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
+
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_TMPVAR(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMPVAR(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMPVAR(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMPVAR(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- call->num_additional_args = 0;
- call->is_ctor_call = 0;
- EX(call) = call;
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
+
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_TMPVAR(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMPVAR(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMPVAR(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMPVAR(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_TMPVAR(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMPVAR(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMPVAR(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMPVAR(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_FETCH_CONSTANT_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
USE_OPLINE
- SAVE_OPLINE();
- if (IS_UNUSED == IS_UNUSED) {
- zend_constant *c;
- zval *retval;
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_TMPVAR(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMPVAR(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMPVAR(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMPVAR(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- if (CACHED_PTR(opline->op2.literal->cache_slot)) {
- c = CACHED_PTR(opline->op2.literal->cache_slot);
- } else if ((c = zend_quick_get_constant(opline->op2.literal + 1, opline->extended_value TSRMLS_CC)) == NULL) {
- if ((opline->extended_value & IS_CONSTANT_UNQUALIFIED) != 0) {
- char *actual = (char *)zend_memrchr(Z_STRVAL_P(opline->op2.zv), '\\', Z_STRLEN_P(opline->op2.zv));
- if(!actual) {
- actual = Z_STRVAL_P(opline->op2.zv);
- } else {
- actual++;
- }
- /* non-qualified constant - allow text substitution */
- zend_error(E_NOTICE, "Use of undefined constant %s - assumed '%s'", actual, actual);
- ZVAL_STRINGL(&EX_T(opline->result.var).tmp_var, actual, Z_STRLEN_P(opline->op2.zv)-(actual - Z_STRVAL_P(opline->op2.zv)), 1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- } else {
- zend_error_noreturn(E_ERROR, "Undefined constant '%s'", Z_STRVAL_P(opline->op2.zv));
- }
- } else {
- CACHE_PTR(opline->op2.literal->cache_slot, c);
- }
- retval = &EX_T(opline->result.var).tmp_var;
- ZVAL_COPY_VALUE(retval, &c->value);
- zval_copy_ctor(retval);
- } else {
- /* class constant */
- zend_class_entry *ce;
- zval **value;
-
- if (IS_UNUSED == IS_CONST) {
- if (CACHED_PTR(opline->op2.literal->cache_slot)) {
- value = CACHED_PTR(opline->op2.literal->cache_slot);
- ZVAL_COPY_VALUE(&EX_T(opline->result.var).tmp_var, *value);
- zval_copy_ctor(&EX_T(opline->result.var).tmp_var);
- goto constant_fetch_end;
- } else if (CACHED_PTR(opline->op1.literal->cache_slot)) {
- ce = CACHED_PTR(opline->op1.literal->cache_slot);
- } else {
- ce = zend_fetch_class_by_name(Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), opline->op1.literal + 1, opline->extended_value TSRMLS_CC);
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- if (UNEXPECTED(ce == NULL)) {
- zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
- }
- CACHE_PTR(opline->op1.literal->cache_slot, ce);
- }
- } else {
- ce = EX_T(opline->op1.var).class_entry;
- if ((value = CACHED_POLYMORPHIC_PTR(opline->op2.literal->cache_slot, ce)) != NULL) {
- ZVAL_COPY_VALUE(&EX_T(opline->result.var).tmp_var, *value);
- zval_copy_ctor(&EX_T(opline->result.var).tmp_var);
- goto constant_fetch_end;
- }
- }
-
- if (EXPECTED(zend_hash_quick_find(&ce->constants_table, Z_STRVAL_P(opline->op2.zv), Z_STRLEN_P(opline->op2.zv)+1, Z_HASH_P(opline->op2.zv), (void **) &value) == SUCCESS)) {
- if (IS_CONSTANT_TYPE(Z_TYPE_PP(value))) {
- zend_class_entry *old_scope = EG(scope);
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
- EG(scope) = ce;
- zval_update_constant(value, 1 TSRMLS_CC);
- EG(scope) = old_scope;
- }
- if (IS_UNUSED == IS_CONST) {
- CACHE_PTR(opline->op2.literal->cache_slot, value);
- } else {
- CACHE_POLYMORPHIC_PTR(opline->op2.literal->cache_slot, ce, value);
- }
- ZVAL_COPY_VALUE(&EX_T(opline->result.var).tmp_var, *value);
- zval_copy_ctor(&EX_T(opline->result.var).tmp_var);
- } else if (Z_STRLEN_P(opline->op2.zv) == sizeof("class")-1 && memcmp(Z_STRVAL_P(opline->op2.zv), "class", sizeof("class") - 1) == 0) {
- /* "class" is assigned as a case-sensitive keyword from zend_do_resolve_class_name */
- ZVAL_STRINGL(&EX_T(opline->result.var).tmp_var, ce->name, ce->name_length, 1);
- } else {
- zend_error_noreturn(E_ERROR, "Undefined class constant '%s'", Z_STRVAL_P(opline->op2.zv));
- }
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_TMPVAR(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-constant_fetch_end:
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMPVAR(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMPVAR(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMPVAR(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
USE_OPLINE
- array_init(&EX_T(opline->result.var).tmp_var);
- if (IS_UNUSED == IS_UNUSED) {
- ZEND_VM_NEXT_OPCODE();
-#if 0 || IS_UNUSED != IS_UNUSED
- } else {
- return ZEND_ADD_ARRAY_ELEMENT_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-#endif
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_TMPVAR(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMPVAR(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMPVAR(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMPVAR(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_UNSET_DIM_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
USE_OPLINE
- zval **container;
- zval *offset;
- ulong hval;
-
- SAVE_OPLINE();
- container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
- if (IS_UNUSED == IS_CV && container != &EG(uninitialized_zval_ptr)) {
- SEPARATE_ZVAL_IF_NOT_REF(container);
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_TMPVAR(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
- offset = opline->op2.zv;
-
- if (IS_UNUSED != IS_VAR || container) {
- switch (Z_TYPE_PP(container)) {
- case IS_ARRAY: {
- HashTable *ht = Z_ARRVAL_PP(container);
-
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- zend_hash_index_del(ht, hval);
- break;
- case IS_RESOURCE:
- case IS_BOOL:
- case IS_LONG:
- hval = Z_LVAL_P(offset);
- zend_hash_index_del(ht, hval);
- break;
- case IS_STRING:
- if (IS_CONST == IS_CV || IS_CONST == IS_VAR) {
- Z_ADDREF_P(offset);
- }
- if (IS_CONST == IS_CONST) {
- hval = Z_HASH_P(offset);
- } else {
- ZEND_HANDLE_NUMERIC_EX(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, goto num_index_dim);
- hval = str_hash(Z_STRVAL_P(offset), Z_STRLEN_P(offset));
- }
- if (ht == &EG(symbol_table)) {
- zend_delete_global_variable_ex(offset->value.str.val, offset->value.str.len, hval TSRMLS_CC);
- } else {
- zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval);
- }
- if (IS_CONST == IS_CV || IS_CONST == IS_VAR) {
- zval_ptr_dtor(&offset);
- }
- break;
-num_index_dim:
- zend_hash_index_del(ht, hval);
- if (IS_CONST == IS_CV || IS_CONST == IS_VAR) {
- zval_ptr_dtor(&offset);
- }
- break;
- case IS_NULL:
- zend_hash_del(ht, "", sizeof(""));
- break;
- default:
- zend_error(E_WARNING, "Illegal offset type in unset");
- break;
- }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMPVAR(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMPVAR(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMPVAR(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- break;
- }
- case IS_OBJECT:
- if (UNEXPECTED(Z_OBJ_HT_P(*container)->unset_dimension == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use object as array");
- }
- if (0) {
- MAKE_REAL_ZVAL_PTR(offset);
- }
- Z_OBJ_HT_P(*container)->unset_dimension(*container, offset TSRMLS_CC);
- if (0) {
- zval_ptr_dtor(&offset);
- } else {
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
- }
- break;
- case IS_STRING:
- zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
- ZEND_VM_CONTINUE(); /* bailed out before */
- default:
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_TMPVAR(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMPVAR(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMPVAR(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMPVAR(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- break;
- }
- } else {
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_TMPVAR(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMPVAR(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMPVAR(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMPVAR(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_UNSET_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
USE_OPLINE
- zval **container;
- zval *offset;
-
- SAVE_OPLINE();
- container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
- offset = opline->op2.zv;
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_TMPVAR(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMPVAR(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMPVAR(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMPVAR(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- if (IS_UNUSED != IS_VAR || container) {
- if (IS_UNUSED == IS_CV && container != &EG(uninitialized_zval_ptr)) {
- SEPARATE_ZVAL_IF_NOT_REF(container);
- }
- if (Z_TYPE_PP(container) == IS_OBJECT) {
- if (0) {
- MAKE_REAL_ZVAL_PTR(offset);
- }
- if (Z_OBJ_HT_P(*container)->unset_property) {
- Z_OBJ_HT_P(*container)->unset_property(*container, offset, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to unset property of non-object");
- }
- if (0) {
- zval_ptr_dtor(&offset);
- } else {
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
- }
- } else {
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_TMPVAR(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMPVAR(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMPVAR(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMPVAR(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- }
- } else {
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
+# if 0 || (IS_UNUSED != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_UNUSED_TMPVAR(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMPVAR(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMPVAR(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMPVAR(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL zend_isset_isempty_dim_prop_obj_handler_SPEC_UNUSED_CONST(int prop_dim, ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_TMPVAR(int inc ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
-
- zval *container;
- zval **value = NULL;
- int result = 0;
- ulong hval;
- zval *offset;
+ zend_free_op free_op2;
+ zval *object;
+ zval *property;
+ zval *zptr;
SAVE_OPLINE();
- container = _get_obj_zval_ptr_unused(TSRMLS_C);
- offset = opline->op2.zv;
+ object = _get_obj_zval_ptr_unused(execute_data);
- if (Z_TYPE_P(container) == IS_ARRAY && !prop_dim) {
- HashTable *ht;
- int isset = 0;
+ if (IS_UNUSED == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ zval_ptr_dtor_nogc(EX_VAR(opline->op2.var));
+ HANDLE_EXCEPTION();
+ }
- ht = Z_ARRVAL_P(container);
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- goto num_index_prop;
- case IS_RESOURCE:
- case IS_BOOL:
- case IS_LONG:
- hval = Z_LVAL_P(offset);
-num_index_prop:
- if (zend_hash_index_find(ht, hval, (void **) &value) == SUCCESS) {
- isset = 1;
- }
- break;
- case IS_STRING:
- if (IS_CONST == IS_CONST) {
- hval = Z_HASH_P(offset);
- } else {
- ZEND_HANDLE_NUMERIC_EX(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, goto num_index_prop);
- hval = str_hash(Z_STRVAL_P(offset), Z_STRLEN_P(offset));
- }
- if (zend_hash_quick_find(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, (void **) &value) == SUCCESS) {
- isset = 1;
- }
- break;
- case IS_NULL:
- if (zend_hash_find(ht, "", sizeof(""), (void **) &value) == SUCCESS) {
- isset = 1;
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot increment/decrement overloaded objects nor string offsets");
+ zval_ptr_dtor_nogc(free_op2);
+ HANDLE_EXCEPTION();
+ }
+
+ do {
+ if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
}
break;
- default:
- zend_error(E_WARNING, "Illegal offset type in isset or empty");
- break;
- }
-
- if (opline->extended_value & ZEND_ISSET) {
- if (isset && Z_TYPE_PP(value) == IS_NULL) {
- result = 0;
- } else {
- result = isset;
- }
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- if (!isset || !i_zend_is_true(*value)) {
- result = 0;
- } else {
- result = 1;
}
}
- } else if (Z_TYPE_P(container) == IS_OBJECT) {
- if (0) {
- MAKE_REAL_ZVAL_PTR(offset);
- }
- if (prop_dim) {
- if (Z_OBJ_HT_P(container)->has_property) {
- result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISEMPTY) != 0, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to check property of non-object");
- result = 0;
- }
- } else {
- if (Z_OBJ_HT_P(container)->has_dimension) {
- result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISEMPTY) != 0 TSRMLS_CC);
+ /* here we are sure we are dealing with an object */
-
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
-
- if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
- if (inc) {
- fast_long_increment_function(zptr);
- } else {
- fast_long_decrement_function(zptr);
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
} else {
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
- zend_error(E_NOTICE, "Trying to check element of non-array");
- result = 0;
- }
- }
- if (0) {
- zval_ptr_dtor(&offset);
- } else {
--
- if (inc) {
- increment_function(zptr);
- }
- } else if (Z_TYPE_P(container) == IS_STRING && !prop_dim) { /* string offsets */
- zval tmp;
++ if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
++ if (inc) {
++ fast_long_increment_function(zptr);
++ } else {
++ fast_long_decrement_function(zptr);
++ }
+ } else {
- decrement_function(zptr);
++ ZVAL_DEREF(zptr);
++ SEPARATE_ZVAL_NOREF(zptr);
+
- if (Z_TYPE_P(offset) != IS_LONG) {
- if (Z_TYPE_P(offset) <= IS_BOOL /* simple scalar types */
- || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
- && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
- ZVAL_COPY_VALUE(&tmp, offset);
- zval_copy_ctor(&tmp);
- convert_to_long(&tmp);
- offset = &tmp;
- } else {
- /* can not be converted to proper offset, return "not set" */
- result = 0;
- }
- }
- if (Z_TYPE_P(offset) == IS_LONG) {
- if (opline->extended_value & ZEND_ISSET) {
- if (offset->value.lval >= 0 && offset->value.lval < Z_STRLEN_P(container)) {
- result = 1;
++ if (inc) {
++ increment_function(zptr);
++ } else {
++ decrement_function(zptr);
++ }
+ }
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- if (offset->value.lval >= 0 && offset->value.lval < Z_STRLEN_P(container) && Z_STRVAL_P(container)[offset->value.lval] != '0') {
- result = 1;
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_COPY(EX_VAR(opline->result.var), zptr);
}
- }
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), zptr);
}
+ } else {
+ zend_pre_incdec_overloaded_property(object, property, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), inc, (UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL));
}
+ } while (0);
- } else {
-
- }
-
- Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
- if (opline->extended_value & ZEND_ISSET) {
- Z_LVAL(EX_T(opline->result.var).tmp_var) = result;
- } else {
- Z_LVAL(EX_T(opline->result.var).tmp_var) = !result;
- }
+ zval_ptr_dtor_nogc(free_op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_isset_isempty_dim_prop_obj_handler_SPEC_UNUSED_CONST(0, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_TAIL_CALL(zend_pre_incdec_property_helper_SPEC_UNUSED_TMPVAR(1 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_isset_isempty_dim_prop_obj_handler_SPEC_UNUSED_CONST(1, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_TAIL_CALL(zend_pre_incdec_property_helper_SPEC_UNUSED_TMPVAR(0 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL ZEND_YIELD_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_TMPVAR(int inc ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
+ zend_free_op free_op2;
+ zval *object;
+ zval *property;
+ zval *zptr;
- /* The generator object is stored in return_value_ptr_ptr */
- zend_generator *generator = (zend_generator *) EG(return_value_ptr_ptr);
+ SAVE_OPLINE();
+ object = _get_obj_zval_ptr_unused(execute_data);
- if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
- zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
+ if (IS_UNUSED == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ zval_ptr_dtor_nogc(EX_VAR(opline->op2.var));
+ HANDLE_EXCEPTION();
}
- /* Destroy the previously yielded value */
- if (generator->value) {
- zval_ptr_dtor(&generator->value);
- }
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- /* Destroy the previously yielded key */
- if (generator->key) {
- zval_ptr_dtor(&generator->key);
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot increment/decrement overloaded objects nor string offsets");
+ zval_ptr_dtor_nogc(free_op2);
+ HANDLE_EXCEPTION();
}
- /* Set the new yielded value */
- if (IS_UNUSED != IS_UNUSED) {
-
-
- if (EX(op_array)->fn_flags & ZEND_ACC_RETURN_REFERENCE) {
- /* Constants and temporary variables aren't yieldable by reference,
- * but we still allow them with a notice. */
- if (IS_UNUSED == IS_CONST || IS_UNUSED == IS_TMP_VAR) {
- zval *value, *copy;
-
- zend_error(E_NOTICE, "Only variable references should be yielded by reference");
-
- value = NULL;
- ALLOC_ZVAL(copy);
- INIT_PZVAL_COPY(copy, value);
+ do {
+ if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ break;
+ }
+ }
- /* Temporary variables don't need ctor copying */
- if (!0) {
- zval_copy_ctor(copy);
- }
+ /* here we are sure we are dealing with an object */
- generator->value = copy;
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
-
- if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
- if (inc) {
- fast_long_increment_function(zptr);
- } else {
- fast_long_decrement_function(zptr);
- }
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
} else {
- ZVAL_DEREF(zptr);
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
- zval_opt_copy_ctor(zptr);
- if (inc) {
- increment_function(zptr);
- zval **value_ptr = NULL;
-
- if (IS_UNUSED == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
- }
-
- /* If a function call result is yielded and the function did
- * not return by reference we throw a notice. */
- if (IS_UNUSED == IS_VAR && !Z_ISREF_PP(value_ptr)
- && !(opline->extended_value == ZEND_RETURNS_FUNCTION
- && EX_T(opline->op1.var).var.fcall_returned_reference)
- && EX_T(opline->op1.var).var.ptr_ptr == &EX_T(opline->op1.var).var.ptr) {
- zend_error(E_NOTICE, "Only variable references should be yielded by reference");
-
- Z_ADDREF_PP(value_ptr);
- generator->value = *value_ptr;
++ if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
++ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
++ if (inc) {
++ fast_long_increment_function(zptr);
++ } else {
++ fast_long_decrement_function(zptr);
++ }
} else {
- decrement_function(zptr);
- SEPARATE_ZVAL_TO_MAKE_IS_REF(value_ptr);
- Z_ADDREF_PP(value_ptr);
- generator->value = *value_ptr;
++ ZVAL_DEREF(zptr);
++ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
++ zval_opt_copy_ctor(zptr);
++ if (inc) {
++ increment_function(zptr);
++ } else {
++ decrement_function(zptr);
++ }
}
-
}
} else {
- zval *value = NULL;
+ zend_post_incdec_overloaded_property(object, property, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), inc, EX_VAR(opline->result.var));
+ }
+ } while (0);
- /* Consts, temporary variables and references need copying */
- if (IS_UNUSED == IS_CONST || IS_UNUSED == IS_TMP_VAR
- || PZVAL_IS_REF(value)
- ) {
- zval *copy;
+ zval_ptr_dtor_nogc(free_op2);
- ALLOC_ZVAL(copy);
- INIT_PZVAL_COPY(copy, value);
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
+}
- /* Temporary variables don't need ctor copying */
- if (!0) {
- zval_copy_ctor(copy);
- }
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ ZEND_VM_TAIL_CALL(zend_post_incdec_property_helper_SPEC_UNUSED_TMPVAR(1 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+}
- generator->value = copy;
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ ZEND_VM_TAIL_CALL(zend_post_incdec_property_helper_SPEC_UNUSED_TMPVAR(0 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+}
- } else {
- if (IS_UNUSED == IS_CV) {
- Z_ADDREF_P(value);
- }
- generator->value = value;
- }
- }
- } else {
- /* If no value was specified yield null */
- Z_ADDREF(EG(uninitialized_zval));
- generator->value = &EG(uninitialized_zval);
- }
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- /* Set the new yielded key */
- if (IS_CONST != IS_UNUSED) {
+ zval *container;
+ zend_free_op free_op2;
+ zval *offset;
- zval *key = opline->op2.zv;
+ SAVE_OPLINE();
+ container = _get_obj_zval_ptr_unused(execute_data);
- /* Consts, temporary variables and references need copying */
- if (IS_CONST == IS_CONST || IS_CONST == IS_TMP_VAR
- || (PZVAL_IS_REF(key) && Z_REFCOUNT_P(key) > 0)
- ) {
- zval *copy;
+ if (IS_UNUSED == IS_UNUSED && UNEXPECTED(Z_OBJ_P(container) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ zval_ptr_dtor_nogc(EX_VAR(opline->op2.var));
+ HANDLE_EXCEPTION();
+ }
- ALLOC_ZVAL(copy);
- INIT_PZVAL_COPY(copy, key);
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- /* Temporary variables don't need ctor copying */
- if (!0) {
- zval_copy_ctor(copy);
+ if (IS_UNUSED == IS_CONST ||
+ (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT))) {
+ if ((IS_UNUSED & (IS_VAR|IS_CV)) && Z_ISREF_P(container)) {
+ container = Z_REFVAL_P(container);
+ if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) {
+ goto fetch_obj_r_no_object;
}
-
- generator->key = copy;
} else {
- Z_ADDREF_P(key);
- generator->key = key;
- }
-
- if (Z_TYPE_P(generator->key) == IS_LONG
- && Z_LVAL_P(generator->key) > generator->largest_used_integer_key
- ) {
- generator->largest_used_integer_key = Z_LVAL_P(generator->key);
+ goto fetch_obj_r_no_object;
}
+ }
- } else {
- /* If no key was specified we use auto-increment keys */
- generator->largest_used_integer_key++;
+ /* here we are sure we are dealing with an object */
+ do {
+ zend_object *zobj = Z_OBJ_P(container);
+ zval *retval;
- ALLOC_INIT_ZVAL(generator->key);
- ZVAL_LONG(generator->key, generator->largest_used_integer_key);
- }
+ if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
+ EXPECTED(zobj->ce == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
+ uint32_t prop_offset = (uint32_t)(intptr_t)CACHED_PTR(Z_CACHE_SLOT_P(offset) + sizeof(void*));
- if (RETURN_VALUE_USED(opline)) {
- /* If the return value of yield is used set the send
- * target and initialize it to NULL */
- generator->send_target = &EX_T(opline->result.var).var.ptr;
- Z_ADDREF(EG(uninitialized_zval));
- EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
- } else {
- generator->send_target = NULL;
- }
+ if (EXPECTED(prop_offset != (uint32_t)ZEND_DYNAMIC_PROPERTY_OFFSET)) {
+ retval = OBJ_PROP(zobj, prop_offset);
+ if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
+ }
+ } else if (EXPECTED(zobj->properties != NULL)) {
+ retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
+ if (EXPECTED(retval)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
+ }
+ }
+ }
- /* We increment to the next op, so we are at the correct position when the
- * generator is resumed. */
- ZEND_VM_INC_OPCODE();
+ if (UNEXPECTED(zobj->handlers->read_property == NULL)) {
+fetch_obj_r_no_object:
+ zend_error(E_NOTICE, "Trying to get property of non-object");
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ } else {
+ retval = zobj->handlers->read_property(container, offset, BP_VAR_R, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var));
- /* The GOTO VM uses a local opline variable. We need to set the opline
- * variable in execute_data so we don't resume at an old position. */
- SAVE_OPLINE();
+ if (retval != EX_VAR(opline->result.var)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ }
+ }
+ } while (0);
- ZEND_VM_RETURN();
+ zval_ptr_dtor_nogc(free_op2);
+
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_FETCH_OBJ_W_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ USE_OPLINE
+ zend_free_op free_op1, free_op2;
+ zval *property;
+ zval *container;
+
+ SAVE_OPLINE();
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+
+ container = _get_obj_zval_ptr_unused(execute_data);
+ if (IS_UNUSED == IS_UNUSED && UNEXPECTED(Z_OBJ_P(container) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ zval_ptr_dtor_nogc(free_op2);
+ HANDLE_EXCEPTION();
+ }
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_throw_error(NULL, "Cannot use string offset as an object");
+ zval_ptr_dtor_nogc(free_op2);
+ HANDLE_EXCEPTION();
+ }
+
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W);
+ zval_ptr_dtor_nogc(free_op2);
+ if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var), 0);
+ }
+
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_FETCH_OBJ_RW_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2, free_op_data1;
- zval **object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
- zval *object;
- zval *property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC);
- zval *value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- int have_get_ptr = 0;
+ zend_free_op free_op1, free_op2;
+ zval *property;
+ zval *container;
+
+ SAVE_OPLINE();
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ container = _get_obj_zval_ptr_unused(execute_data);
- if (IS_UNUSED == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+ if (IS_UNUSED == IS_UNUSED && UNEXPECTED(Z_OBJ_P(container) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ zval_ptr_dtor_nogc(free_op2);
+ HANDLE_EXCEPTION();
+ }
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_throw_error(NULL, "Cannot use string offset as an object");
+ zval_ptr_dtor_nogc(free_op2);
+ HANDLE_EXCEPTION();
+ }
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW);
+ zval_ptr_dtor_nogc(free_op2);
+ if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var), 0);
}
- make_real_object(object_ptr TSRMLS_CC);
- object = *object_ptr;
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
+}
- if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to assign property of non-object");
- zval_dtor(free_op2.var);
- FREE_OP(free_op_data1);
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
- }
- } else {
- /* here we are sure we are dealing with an object */
- if (1) {
- MAKE_REAL_ZVAL_PTR(property);
- }
+ zval *container;
+ zend_free_op free_op2;
+ zval *offset;
- /* here property is a string */
- if (opline->extended_value == ZEND_ASSIGN_OBJ
- && Z_OBJ_HT_P(object)->get_property_ptr_ptr) {
- zval **zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- if (zptr != NULL) { /* NULL means no success in getting PTR */
- have_get_ptr = 1;
- if (UNEXPECTED(*zptr == &EG(error_zval))) {
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
- }
- } else {
- SEPARATE_ZVAL_IF_NOT_REF(zptr);
+ SAVE_OPLINE();
+ container = _get_obj_zval_ptr_unused(execute_data);
- binary_op(*zptr, *zptr, value TSRMLS_CC);
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(*zptr);
- EX_T(opline->result.var).var.ptr = *zptr;
- }
- }
+ if (IS_UNUSED == IS_UNUSED && UNEXPECTED(Z_OBJ_P(container) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ zval_ptr_dtor_nogc(EX_VAR(opline->op2.var));
+ HANDLE_EXCEPTION();
+ }
+
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+
+ if (IS_UNUSED == IS_CONST ||
+ (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT))) {
+ if ((IS_UNUSED & (IS_VAR|IS_CV)) && Z_ISREF_P(container)) {
+ container = Z_REFVAL_P(container);
+ if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) {
+ goto fetch_obj_is_no_object;
}
+ } else {
+ goto fetch_obj_is_no_object;
}
+ }
- if (!have_get_ptr) {
- zval *z = NULL;
+ /* here we are sure we are dealing with an object */
+ do {
+ zend_object *zobj = Z_OBJ_P(container);
+ zval *retval;
- Z_ADDREF_P(object);
- if (opline->extended_value == ZEND_ASSIGN_OBJ) {
- if (Z_OBJ_HT_P(object)->read_property) {
- z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- }
- } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
- if (Z_OBJ_HT_P(object)->read_dimension) {
- z = Z_OBJ_HT_P(object)->read_dimension(object, property, BP_VAR_R TSRMLS_CC);
- }
- }
- if (z) {
- if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
- zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
+ if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
+ EXPECTED(zobj->ce == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
+ uint32_t prop_offset = (uint32_t)(intptr_t)CACHED_PTR(Z_CACHE_SLOT_P(offset) + sizeof(void*));
- if (Z_REFCOUNT_P(z) == 0) {
- GC_REMOVE_ZVAL_FROM_BUFFER(z);
- zval_dtor(z);
- FREE_ZVAL(z);
- }
- z = value;
- }
- Z_ADDREF_P(z);
- SEPARATE_ZVAL_IF_NOT_REF(&z);
- binary_op(z, z, value TSRMLS_CC);
- if (opline->extended_value == ZEND_ASSIGN_OBJ) {
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
- Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
- }
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(z);
- EX_T(opline->result.var).var.ptr = z;
+ if (EXPECTED(prop_offset != (uint32_t)ZEND_DYNAMIC_PROPERTY_OFFSET)) {
+ retval = OBJ_PROP(zobj, prop_offset);
+ if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
}
- zval_ptr_dtor(&z);
- } else {
- zend_error(E_WARNING, "Attempt to assign property of non-object");
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+ } else if (EXPECTED(zobj->properties != NULL)) {
+ retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
+ if (EXPECTED(retval)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
}
}
- zval_ptr_dtor(&object);
}
- if (1) {
- zval_ptr_dtor(&property);
+ if (UNEXPECTED(zobj->handlers->read_property == NULL)) {
+fetch_obj_is_no_object:
+ ZVAL_NULL(EX_VAR(opline->result.var));
} else {
- zval_dtor(free_op2.var);
+
+ retval = zobj->handlers->read_property(container, offset, BP_VAR_IS, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var));
+
+ if (retval != EX_VAR(opline->result.var)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ }
}
- FREE_OP(free_op_data1);
- }
+ } while (0);
- /* assign_obj has two opcodes! */
- CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
+ zval_ptr_dtor_nogc(free_op2);
+
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2, free_op_data2, free_op_data1;
- zval **var_ptr;
- zval *value;
-
- SAVE_OPLINE();
- switch (opline->extended_value) {
- case ZEND_ASSIGN_OBJ:
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- break;
- case ZEND_ASSIGN_DIM: {
- zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
-
- if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- } else if (UNEXPECTED(Z_TYPE_PP(container) == IS_OBJECT)) {
- if (IS_UNUSED == IS_VAR && !0) {
- Z_ADDREF_PP(container); /* undo the effect of get_obj_zval_ptr_ptr() */
- }
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else {
- zval *dim = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC);
+ zval *container;
- zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), container, dim, IS_TMP_VAR, BP_VAR_RW TSRMLS_CC);
- value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- var_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, execute_data, &free_op_data2 TSRMLS_CC);
- }
- }
- break;
- default:
- value = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC);
- var_ptr = NULL;
- /* do nothing */
- break;
- }
+ if (zend_is_by_ref_func_arg_fetch(opline, EX(call))) {
+ /* Behave like FETCH_OBJ_W */
+ zend_free_op free_op1, free_op2;
+ zval *property;
- if (UNEXPECTED(var_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
- }
+ SAVE_OPLINE();
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ container = _get_obj_zval_ptr_unused(execute_data);
- if (UNEXPECTED(*var_ptr == &EG(error_zval))) {
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+ if (IS_UNUSED == IS_UNUSED && UNEXPECTED(Z_OBJ_P(container) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ zval_ptr_dtor_nogc(free_op2);
+ HANDLE_EXCEPTION();
}
- zval_dtor(free_op2.var);
+ if (IS_UNUSED == IS_CONST || IS_UNUSED == IS_TMP_VAR) {
+ zend_throw_error(NULL, "Cannot use temporary expression in write context");
+ zval_ptr_dtor_nogc(free_op2);
- CHECK_EXCEPTION();
- if (opline->extended_value == ZEND_ASSIGN_DIM) {
- ZEND_VM_INC_OPCODE();
+ HANDLE_EXCEPTION();
+ }
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_throw_error(NULL, "Cannot use string offset as an object");
+ zval_ptr_dtor_nogc(free_op2);
+ HANDLE_EXCEPTION();
+ }
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W);
+ zval_ptr_dtor_nogc(free_op2);
+ if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var), 0);
}
- ZEND_VM_NEXT_OPCODE();
- }
-
- SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
- if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
- && Z_OBJ_HANDLER_PP(var_ptr, get)
- && Z_OBJ_HANDLER_PP(var_ptr, set)) {
- /* proxy object */
- zval *objval = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
- Z_ADDREF_P(objval);
- binary_op(objval, objval, value TSRMLS_CC);
- Z_OBJ_HANDLER_PP(var_ptr, set)(var_ptr, objval TSRMLS_CC);
- zval_ptr_dtor(&objval);
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
} else {
- binary_op(*var_ptr, *var_ptr, value TSRMLS_CC);
+ ZEND_VM_TAIL_CALL(ZEND_FETCH_OBJ_R_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU));
}
+}
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(*var_ptr);
- EX_T(opline->result.var).var.ptr = *var_ptr;
- }
- zval_dtor(free_op2.var);
-
- if (opline->extended_value == ZEND_ASSIGN_DIM) {
- FREE_OP(free_op_data1);
- FREE_OP_VAR_PTR(free_op_data2);
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1, free_op2;
+ zval *container, *property;
- CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
- } else {
+ SAVE_OPLINE();
+ container = _get_obj_zval_ptr_unused(execute_data);
- CHECK_EXCEPTION();
+ if (IS_UNUSED == IS_UNUSED && UNEXPECTED(Z_OBJ_P(container) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ zval_ptr_dtor_nogc(EX_VAR(opline->op2.var));
+ HANDLE_EXCEPTION();
}
- ZEND_VM_NEXT_OPCODE();
-}
-static int ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-static int ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_throw_error(NULL, "Cannot use string offset as an object");
+ zval_ptr_dtor_nogc(free_op2);
+ HANDLE_EXCEPTION();
+ }
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET);
+ zval_ptr_dtor_nogc(free_op2);
+ if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var), 0);
+ }
-static int ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_OBJ_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ USE_OPLINE
+ zend_free_op free_op2;
+ zval *object;
+ zval *property_name;
-static int ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ SAVE_OPLINE();
+ object = _get_obj_zval_ptr_unused(execute_data);
-static int ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ if (IS_UNUSED == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ zval_ptr_dtor_nogc(EX_VAR(opline->op2.var));
+ HANDLE_EXCEPTION();
+ }
-static int ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ property_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-static int ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot use string offset as an array");
+ zval_ptr_dtor_nogc(free_op2);
+ HANDLE_EXCEPTION();
+ }
+ zend_assign_to_object(UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL, object, IS_UNUSED, property_name, (IS_TMP_VAR|IS_VAR), (opline+1)->op1_type, (opline+1)->op1, execute_data, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property_name)) : NULL));
+ zval_ptr_dtor_nogc(free_op2);
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ /* assign_obj has two opcodes! */
+ ZEND_VM_NEXT_OPCODE_EX(1, 2);
}
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ROPE_INIT_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ USE_OPLINE
+ zend_free_op free_op2;
+ zend_string **rope;
+ zval *var;
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ /* Compiler allocates the necessary number of zval slots to keep the rope */
+ rope = (zend_string**)EX_VAR(opline->result.var);
+ if ((IS_TMP_VAR|IS_VAR) == IS_CONST) {
+ var = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ rope[0] = zend_string_copy(Z_STR_P(var));
+ } else {
+ var = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ if (EXPECTED(Z_TYPE_P(var) == IS_STRING)) {
+ if ((IS_TMP_VAR|IS_VAR) == IS_CV) {
+ rope[0] = zend_string_copy(Z_STR_P(var));
+ } else {
+ rope[0] = Z_STR_P(var);
+ }
+ } else {
+ SAVE_OPLINE();
+ if ((IS_TMP_VAR|IS_VAR) == IS_CV && UNEXPECTED(Z_TYPE_P(var) == IS_UNDEF)) {
+ GET_OP2_UNDEF_CV(var, BP_VAR_R);
+ }
+ rope[0] = _zval_get_string_func(var);
+ zval_ptr_dtor_nogc(free_op2);
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
+ }
+ }
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_TMP(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *function_name;
zend_free_op free_op2;
- zval **object_ptr;
zval *object;
- zval *property;
- zval **retval;
- int have_get_ptr = 0;
+ zend_function *fbc;
+ zend_class_entry *called_scope;
+ zend_object *obj;
+ zend_execute_data *call;
+ uint32_t call_info;
SAVE_OPLINE();
- object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC);
- retval = &EX_T(opline->result.var).var.ptr;
-
- if (IS_UNUSED == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
- make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
- object = *object_ptr;
+ function_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- zval_dtor(free_op2.var);
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- *retval = &EG(uninitialized_zval);
- }
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST &&
+ UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
+ do {
+ if (((IS_TMP_VAR|IS_VAR) & (IS_VAR|IS_CV)) && Z_ISREF_P(function_name)) {
+ function_name = Z_REFVAL_P(function_name);
+ if (EXPECTED(Z_TYPE_P(function_name) == IS_STRING)) {
+ break;
+ }
+ } else if ((IS_TMP_VAR|IS_VAR) == IS_CV && UNEXPECTED(Z_TYPE_P(function_name) == IS_UNDEF)) {
+ GET_OP2_UNDEF_CV(function_name, BP_VAR_R);
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ }
+ zend_throw_error(NULL, "Method name must be a string");
+ zval_ptr_dtor_nogc(free_op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ HANDLE_EXCEPTION();
+ } while (0);
}
- /* here we are sure we are dealing with an object */
+ object = _get_obj_zval_ptr_unused(execute_data);
- if (1) {
- MAKE_REAL_ZVAL_PTR(property);
+ if (IS_UNUSED == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ zval_ptr_dtor_nogc(free_op2);
+ HANDLE_EXCEPTION();
}
- if (Z_OBJ_HT_P(object)->get_property_ptr_ptr) {
- zval **zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- if (zptr != NULL) { /* NULL means no success in getting PTR */
- have_get_ptr = 1;
- if (UNEXPECTED(*zptr == &EG(error_zval))) {
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- *retval = &EG(uninitialized_zval);
+ if (IS_UNUSED != IS_UNUSED) {
+ do {
+ if (IS_UNUSED == IS_CONST || UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ if ((IS_UNUSED & (IS_VAR|IS_CV)) && EXPECTED(Z_ISREF_P(object))) {
+ object = Z_REFVAL_P(object);
+ if (EXPECTED(Z_TYPE_P(object) == IS_OBJECT)) {
+ break;
+ }
}
- } else {
- SEPARATE_ZVAL_IF_NOT_REF(zptr);
-
- incdec_op(*zptr);
- if (RETURN_VALUE_USED(opline)) {
- *retval = *zptr;
- PZVAL_LOCK(*retval);
+ if (IS_UNUSED == IS_CV && UNEXPECTED(Z_TYPE_P(object) == IS_UNDEF)) {
+ object = GET_OP1_UNDEF_CV(object, BP_VAR_R);
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ zval_ptr_dtor_nogc(free_op2);
+ HANDLE_EXCEPTION();
+ }
}
+ zend_throw_error(NULL, "Call to a member function %s() on %s", Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
+ zval_ptr_dtor_nogc(free_op2);
+
+ HANDLE_EXCEPTION();
}
- }
+ } while (0);
}
- if (!have_get_ptr) {
- if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval *z;
+ obj = Z_OBJ_P(object);
+ called_scope = obj->ce;
- Z_ADDREF_P(object);
- z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST ||
+ UNEXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
+ zend_object *orig_obj = obj;
- if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
- zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
+ if (UNEXPECTED(obj->handlers->get_method == NULL)) {
+ zend_throw_error(NULL, "Object does not support method calls");
+ zval_ptr_dtor_nogc(free_op2);
- if (Z_REFCOUNT_P(z) == 0) {
- GC_REMOVE_ZVAL_FROM_BUFFER(z);
- zval_dtor(z);
- FREE_ZVAL(z);
- }
- z = value;
- }
- Z_ADDREF_P(z);
- SEPARATE_ZVAL_IF_NOT_REF(&z);
- incdec_op(z);
- *retval = z;
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- zval_ptr_dtor(&object);
- SELECTIVE_PZVAL_LOCK(*retval, opline);
- zval_ptr_dtor(&z);
- } else {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- *retval = &EG(uninitialized_zval);
+ HANDLE_EXCEPTION();
+ }
+
+ /* First, locate the function. */
+ fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX_CONSTANT(opline->op2) + 1) : NULL));
+ if (UNEXPECTED(fbc == NULL)) {
+ if (EXPECTED(!EG(exception))) {
+ zend_throw_error(NULL, "Call to undefined method %s::%s()", ZSTR_VAL(obj->ce->name), Z_STRVAL_P(function_name));
}
+ zval_ptr_dtor_nogc(free_op2);
+
+ HANDLE_EXCEPTION();
+ }
+ if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
+ EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
+ EXPECTED(!(fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_TRAMPOLINE|ZEND_ACC_NEVER_CACHE))) &&
+ EXPECTED(obj == orig_obj)) {
+ CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope, fbc);
}
}
{
USE_OPLINE
- /* The generator object is stored in return_value_ptr_ptr */
- zend_generator *generator = (zend_generator *) EG(return_value_ptr_ptr);
+ zval *op1, *op2;
- if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
- zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
- }
+ SAVE_OPLINE();
+ op1 = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var);
+ op2 = EX_CONSTANT(opline->op2);
+ bitwise_xor_function(EX_VAR(opline->result.var), op1, op2);
- /* Destroy the previously yielded value */
- if (generator->value) {
- zval_ptr_dtor(&generator->value);
- }
- /* Destroy the previously yielded key */
- if (generator->key) {
- zval_ptr_dtor(&generator->key);
- }
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
+}
- /* Set the new yielded value */
- if (IS_UNUSED != IS_UNUSED) {
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_BOOL_XOR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zval *op1, *op2;
- if (EX(op_array)->fn_flags & ZEND_ACC_RETURN_REFERENCE) {
- /* Constants and temporary variables aren't yieldable by reference,
- * but we still allow them with a notice. */
- if (IS_UNUSED == IS_CONST || IS_UNUSED == IS_TMP_VAR) {
- zval *value, *copy;
+ SAVE_OPLINE();
+ op1 = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var);
+ op2 = EX_CONSTANT(opline->op2);
+ boolean_xor_function(EX_VAR(opline->result.var), op1, op2);
- zend_error(E_NOTICE, "Only variable references should be yielded by reference");
- value = NULL;
- ALLOC_ZVAL(copy);
- INIT_PZVAL_COPY(copy, value);
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
+}
- /* Temporary variables don't need ctor copying */
- if (!0) {
- zval_copy_ctor(copy);
- }
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_CONST(binary_op_type binary_op ZEND_OPCODE_HANDLER_ARGS_DC)
+{
+ USE_OPLINE
+ zend_free_op free_op_data1;
+ zval *object;
+ zval *property;
+ zval *value;
+ zval *zptr;
- generator->value = copy;
- } else {
- zval **value_ptr = NULL;
+ SAVE_OPLINE();
+ object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var);
- if (IS_UNUSED == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
- }
+ if (IS_CV == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
- /* If a function call result is yielded and the function did
- * not return by reference we throw a notice. */
- if (IS_UNUSED == IS_VAR && !Z_ISREF_PP(value_ptr)
- && !(opline->extended_value == ZEND_RETURNS_FUNCTION
- && EX_T(opline->op1.var).var.fcall_returned_reference)
- && EX_T(opline->op1.var).var.ptr_ptr == &EX_T(opline->op1.var).var.ptr) {
- zend_error(E_NOTICE, "Only variable references should be yielded by reference");
-
- Z_ADDREF_PP(value_ptr);
- generator->value = *value_ptr;
- } else {
- SEPARATE_ZVAL_TO_MAKE_IS_REF(value_ptr);
- Z_ADDREF_PP(value_ptr);
- generator->value = *value_ptr;
- }
-
- }
- } else {
- zval *value = NULL;
+ HANDLE_EXCEPTION();
+ }
- /* Consts, temporary variables and references need copying */
- if (IS_UNUSED == IS_CONST || IS_UNUSED == IS_TMP_VAR
- || PZVAL_IS_REF(value)
- ) {
- zval *copy;
+ property = EX_CONSTANT(opline->op2);
- ALLOC_ZVAL(copy);
- INIT_PZVAL_COPY(copy, value);
+ if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot use string offset as an object");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
- /* Temporary variables don't need ctor copying */
- if (!0) {
- zval_copy_ctor(copy);
- }
+ HANDLE_EXCEPTION();
+ }
- generator->value = copy;
+ do {
+ value = get_zval_ptr_r((opline+1)->op1_type, (opline+1)->op1, execute_data, &free_op_data1);
- } else {
- if (IS_UNUSED == IS_CV) {
- Z_ADDREF_P(value);
+ if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to assign property of non-object");
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
}
- generator->value = value;
+ break;
}
}
- } else {
- /* If no value was specified yield null */
- Z_ADDREF(EG(uninitialized_zval));
- generator->value = &EG(uninitialized_zval);
- }
-
- /* Set the new yielded key */
- if (IS_UNUSED != IS_UNUSED) {
-
- zval *key = NULL;
-
- /* Consts, temporary variables and references need copying */
- if (IS_UNUSED == IS_CONST || IS_UNUSED == IS_TMP_VAR
- || (PZVAL_IS_REF(key) && Z_REFCOUNT_P(key) > 0)
- ) {
- zval *copy;
- ALLOC_ZVAL(copy);
- INIT_PZVAL_COPY(copy, key);
+ /* here we are sure we are dealing with an object */
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
++ }
++ } else {
++ ZVAL_DEREF(zptr);
++ SEPARATE_ZVAL_NOREF(zptr);
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
-
- binary_op(zptr, zptr, value);
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), zptr);
- /* Temporary variables don't need ctor copying */
- if (!0) {
- zval_copy_ctor(copy);
++ binary_op(zptr, zptr, value);
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_COPY(EX_VAR(opline->result.var), zptr);
++ }
}
-
- generator->key = copy;
} else {
- Z_ADDREF_P(key);
- generator->key = key;
- }
-
- if (Z_TYPE_P(generator->key) == IS_LONG
- && Z_LVAL_P(generator->key) > generator->largest_used_integer_key
- ) {
- generator->largest_used_integer_key = Z_LVAL_P(generator->key);
+ zend_assign_op_overloaded_property(object, property, ((IS_CONST == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), value, binary_op, (UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL));
}
+ } while (0);
- } else {
- /* If no key was specified we use auto-increment keys */
- generator->largest_used_integer_key++;
-
- ALLOC_INIT_ZVAL(generator->key);
- ZVAL_LONG(generator->key, generator->largest_used_integer_key);
- }
-
- if (RETURN_VALUE_USED(opline)) {
- /* If the return value of yield is used set the send
- * target and initialize it to NULL */
- generator->send_target = &EX_T(opline->result.var).var.ptr;
- Z_ADDREF(EG(uninitialized_zval));
- EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
- } else {
- generator->send_target = NULL;
- }
-
- /* We increment to the next op, so we are at the correct position when the
- * generator is resumed. */
- ZEND_VM_INC_OPCODE();
-
- /* The GOTO VM uses a local opline variable. We need to set the opline
- * variable in execute_data so we don't resume at an old position. */
- SAVE_OPLINE();
+ FREE_OP(free_op_data1);
- ZEND_VM_RETURN();
-}
-static int ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_UNUSED_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_binary_assign_op_helper_SPEC_UNUSED_UNUSED(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ /* assign_obj has two opcodes! */
+ ZEND_VM_NEXT_OPCODE_EX(1, 2);
}
-static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_CV(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_CV_CONST(binary_op_type binary_op ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
zend_free_op free_op_data1;
{
USE_OPLINE
- zval **object_ptr;
zval *object;
zval *property;
- zval **retval;
- int have_get_ptr = 0;
+ zval *zptr;
SAVE_OPLINE();
- object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
- property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
- retval = &EX_T(opline->result.var).var.ptr;
-
- if (IS_UNUSED == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
-
- make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
- object = *object_ptr;
+ object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var);
- if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- *retval = &EG(uninitialized_zval);
- }
+ if (IS_CV == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ HANDLE_EXCEPTION();
}
- /* here we are sure we are dealing with an object */
+ property = EX_CONSTANT(opline->op2);
- if (0) {
- MAKE_REAL_ZVAL_PTR(property);
- }
+ if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot increment/decrement overloaded objects nor string offsets");
- if (Z_OBJ_HT_P(object)->get_property_ptr_ptr) {
- zval **zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- if (zptr != NULL) { /* NULL means no success in getting PTR */
- have_get_ptr = 1;
- if (UNEXPECTED(*zptr == &EG(error_zval))) {
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- *retval = &EG(uninitialized_zval);
- }
- } else {
- SEPARATE_ZVAL_IF_NOT_REF(zptr);
+ HANDLE_EXCEPTION();
+ }
- incdec_op(*zptr);
- if (RETURN_VALUE_USED(opline)) {
- *retval = *zptr;
- PZVAL_LOCK(*retval);
+ do {
+ if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
}
+ break;
}
}
- }
-
- if (!have_get_ptr) {
- if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval *z;
-
- Z_ADDREF_P(object);
- z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
- zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
+ /* here we are sure we are dealing with an object */
-
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
-
- if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
- if (inc) {
- fast_long_increment_function(zptr);
- } else {
- fast_long_decrement_function(zptr);
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
-
- if (inc) {
- increment_function(zptr);
++ if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
++ if (inc) {
++ fast_long_increment_function(zptr);
++ } else {
++ fast_long_decrement_function(zptr);
++ }
+ } else {
- decrement_function(zptr);
++ ZVAL_DEREF(zptr);
++ SEPARATE_ZVAL_NOREF(zptr);
+
- if (Z_REFCOUNT_P(z) == 0) {
- GC_REMOVE_ZVAL_FROM_BUFFER(z);
- zval_dtor(z);
- FREE_ZVAL(z);
++ if (inc) {
++ increment_function(zptr);
++ } else {
++ decrement_function(zptr);
++ }
++ }
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_COPY(EX_VAR(opline->result.var), zptr);
}
- }
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), zptr);
- z = value;
}
- Z_ADDREF_P(z);
- SEPARATE_ZVAL_IF_NOT_REF(&z);
- incdec_op(z);
- *retval = z;
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- zval_ptr_dtor(&object);
- SELECTIVE_PZVAL_LOCK(*retval, opline);
- zval_ptr_dtor(&z);
} else {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- *retval = &EG(uninitialized_zval);
- }
+ zend_pre_incdec_overloaded_property(object, property, ((IS_CONST == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), inc, (UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL));
}
- }
-
- if (0) {
- zval_ptr_dtor(&property);
- } else {
+ } while (0);
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_pre_incdec_property_helper_SPEC_UNUSED_CV(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_TAIL_CALL(zend_pre_incdec_property_helper_SPEC_CV_CONST(1 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_pre_incdec_property_helper_SPEC_UNUSED_CV(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_TAIL_CALL(zend_pre_incdec_property_helper_SPEC_CV_CONST(0 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_CV(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CONST(int inc ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
- zval **object_ptr;
zval *object;
zval *property;
- zval *retval;
- int have_get_ptr = 0;
+ zval *zptr;
SAVE_OPLINE();
- object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
- property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
- retval = &EX_T(opline->result.var).tmp_var;
+ object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var);
- if (IS_UNUSED == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
+ if (IS_CV == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
- make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
- object = *object_ptr;
+ HANDLE_EXCEPTION();
+ }
- if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ property = EX_CONSTANT(opline->op2);
- ZVAL_NULL(retval);
+ if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot increment/decrement overloaded objects nor string offsets");
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ HANDLE_EXCEPTION();
}
- /* here we are sure we are dealing with an object */
+ do {
+ if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ break;
+ }
+ }
- if (0) {
- MAKE_REAL_ZVAL_PTR(property);
- }
+ /* here we are sure we are dealing with an object */
- if (Z_OBJ_HT_P(object)->get_property_ptr_ptr) {
- zval **zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- if (zptr != NULL) { /* NULL means no success in getting PTR */
- have_get_ptr = 1;
- if (UNEXPECTED(*zptr == &EG(error_zval))) {
- ZVAL_NULL(retval);
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
-
- if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
- if (inc) {
- fast_long_increment_function(zptr);
- } else {
- fast_long_decrement_function(zptr);
- }
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
} else {
- ZVAL_DEREF(zptr);
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
- zval_opt_copy_ctor(zptr);
- if (inc) {
- increment_function(zptr);
- SEPARATE_ZVAL_IF_NOT_REF(zptr);
-
- ZVAL_COPY_VALUE(retval, *zptr);
- zendi_zval_copy_ctor(*retval);
-
- incdec_op(*zptr);
- }
- }
- }
-
- if (!have_get_ptr) {
- if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval *z, *z_copy;
-
- Z_ADDREF_P(object);
- z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
- zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
-
- if (Z_REFCOUNT_P(z) == 0) {
- GC_REMOVE_ZVAL_FROM_BUFFER(z);
- zval_dtor(z);
- FREE_ZVAL(z);
++ if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
++ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
++ if (inc) {
++ fast_long_increment_function(zptr);
++ } else {
++ fast_long_decrement_function(zptr);
++ }
+ } else {
- decrement_function(zptr);
++ ZVAL_DEREF(zptr);
++ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
++ zval_opt_copy_ctor(zptr);
++ if (inc) {
++ increment_function(zptr);
++ } else {
++ decrement_function(zptr);
++ }
}
- z = value;
}
- ZVAL_COPY_VALUE(retval, z);
- zendi_zval_copy_ctor(*retval);
- ALLOC_ZVAL(z_copy);
- INIT_PZVAL_COPY(z_copy, z);
- zendi_zval_copy_ctor(*z_copy);
- incdec_op(z_copy);
- Z_ADDREF_P(z);
- Z_OBJ_HT_P(object)->write_property(object, property, z_copy, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- zval_ptr_dtor(&object);
- zval_ptr_dtor(&z_copy);
- zval_ptr_dtor(&z);
} else {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- ZVAL_NULL(retval);
+ zend_post_incdec_overloaded_property(object, property, ((IS_CONST == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), inc, EX_VAR(opline->result.var));
}
- }
-
- if (0) {
- zval_ptr_dtor(&property);
- } else {
+ } while (0);
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_post_incdec_property_helper_SPEC_UNUSED_CV(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_TAIL_CALL(zend_post_incdec_property_helper_SPEC_CV_CONST(1 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_post_incdec_property_helper_SPEC_UNUSED_CV(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_TAIL_CALL(zend_post_incdec_property_helper_SPEC_CV_CONST(0 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_UNUSED_CV(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CV_CONST(int type ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
{
USE_OPLINE
+ zval *op1, *op2;
SAVE_OPLINE();
- pow_function(&EX_T(opline->result.var).tmp_var,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
-
+ op1 = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var);
+ op2 = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var);
+ compare_function(EX_VAR(opline->result.var), op1, op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-static int ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_binary_assign_op_helper_SPEC_CV_CONST(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_ADD_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_BW_OR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
+
+ zval *op1, *op2;
SAVE_OPLINE();
- fast_add_function(&EX_T(opline->result.var).tmp_var,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC) TSRMLS_CC);
+ op1 = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var);
+ op2 = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var);
+ bitwise_or_function(EX_VAR(opline->result.var), op1, op2);
- zval_dtor(free_op2.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_SUB_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_BW_AND_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
+
+ zval *op1, *op2;
SAVE_OPLINE();
- fast_sub_function(&EX_T(opline->result.var).tmp_var,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC) TSRMLS_CC);
+ op1 = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var);
+ op2 = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var);
+ bitwise_and_function(EX_VAR(opline->result.var), op1, op2);
- zval_dtor(free_op2.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_MUL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_BW_XOR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
+
+ zval *op1, *op2;
SAVE_OPLINE();
- fast_mul_function(&EX_T(opline->result.var).tmp_var,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC) TSRMLS_CC);
+ op1 = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var);
+ op2 = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var);
+ bitwise_xor_function(EX_VAR(opline->result.var), op1, op2);
- zval_dtor(free_op2.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_DIV_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_BOOL_XOR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
+
+ zval *op1, *op2;
SAVE_OPLINE();
- fast_div_function(&EX_T(opline->result.var).tmp_var,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC) TSRMLS_CC);
+ op1 = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var);
+ op2 = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var);
+ boolean_xor_function(EX_VAR(opline->result.var), op1, op2);
- zval_dtor(free_op2.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_MOD_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_CV(binary_op_type binary_op ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
- zend_free_op free_op2;
+ zend_free_op free_op_data1;
+ zval *object;
+ zval *property;
+ zval *value;
+ zval *zptr;
SAVE_OPLINE();
- fast_mod_function(&EX_T(opline->result.var).tmp_var,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC) TSRMLS_CC);
+ object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var);
- zval_dtor(free_op2.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_SL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
+ if (IS_CV == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
- SAVE_OPLINE();
- shift_left_function(&EX_T(opline->result.var).tmp_var,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC) TSRMLS_CC);
+ HANDLE_EXCEPTION();
+ }
- zval_dtor(free_op2.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var);
-static int ZEND_FASTCALL ZEND_SR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
+ if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot use string offset as an object");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
- SAVE_OPLINE();
- shift_right_function(&EX_T(opline->result.var).tmp_var,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC) TSRMLS_CC);
+ HANDLE_EXCEPTION();
+ }
- zval_dtor(free_op2.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ do {
+ value = get_zval_ptr_r((opline+1)->op1_type, (opline+1)->op1, execute_data, &free_op_data1);
-static int ZEND_FASTCALL ZEND_CONCAT_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
+ if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to assign property of non-object");
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ break;
+ }
+ }
- SAVE_OPLINE();
- concat_function(&EX_T(opline->result.var).tmp_var,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC) TSRMLS_CC);
+ /* here we are sure we are dealing with an object */
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CV == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
++ }
++ } else {
++ ZVAL_DEREF(zptr);
++ SEPARATE_ZVAL_NOREF(zptr);
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
-
- binary_op(zptr, zptr, value);
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), zptr);
- zval_dtor(free_op2.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
++ binary_op(zptr, zptr, value);
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_COPY(EX_VAR(opline->result.var), zptr);
++ }
+ }
+ } else {
+ zend_assign_op_overloaded_property(object, property, ((IS_CV == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), value, binary_op, (UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL));
+ }
+ } while (0);
-static int ZEND_FASTCALL ZEND_IS_IDENTICAL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
+ FREE_OP(free_op_data1);
- SAVE_OPLINE();
- is_identical_function(&EX_T(opline->result.var).tmp_var,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC) TSRMLS_CC);
- zval_dtor(free_op2.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ /* assign_obj has two opcodes! */
+ ZEND_VM_NEXT_OPCODE_EX(1, 2);
}
-static int ZEND_FASTCALL ZEND_IS_NOT_IDENTICAL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_CV_CV(binary_op_type binary_op ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
- zend_free_op free_op2;
- zval *result = &EX_T(opline->result.var).tmp_var;
+ zend_free_op free_op_data1;
+ zval *var_ptr, rv;
+ zval *value, *container, *dim;
SAVE_OPLINE();
- is_identical_function(result,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC) TSRMLS_CC);
- Z_LVAL_P(result) = !Z_LVAL_P(result);
+ container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var);
+ if (IS_CV == IS_UNUSED && UNEXPECTED(Z_OBJ_P(container) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
- zval_dtor(free_op2.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ HANDLE_EXCEPTION();
+ }
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_throw_error(NULL, "Cannot use string offset as an array");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
-static int ZEND_FASTCALL ZEND_IS_EQUAL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
- zval *result = &EX_T(opline->result.var).tmp_var;
+ HANDLE_EXCEPTION();
+ }
- SAVE_OPLINE();
- ZVAL_BOOL(result, fast_equal_function(result,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC) TSRMLS_CC));
+ dim = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var);
- zval_dtor(free_op2.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ do {
+ if (IS_CV == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) != IS_ARRAY)) {
+ if (IS_CV != IS_UNUSED) {
+ ZVAL_DEREF(container);
+ }
+ if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ value = get_zval_ptr_r((opline+1)->op1_type, (opline+1)->op1, execute_data, &free_op_data1);
+ zend_binary_assign_op_obj_dim(container, dim, value, UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL, binary_op);
+ break;
+ }
+ }
-static int ZEND_FASTCALL ZEND_IS_NOT_EQUAL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
- zval *result = &EX_T(opline->result.var).tmp_var;
+ zend_fetch_dimension_address_RW(&rv, container, dim, IS_CV);
+ value = get_zval_ptr_r((opline+1)->op1_type, (opline+1)->op1, execute_data, &free_op_data1);
+ ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+ var_ptr = Z_INDIRECT(rv);
- SAVE_OPLINE();
- ZVAL_BOOL(result, fast_not_equal_function(result,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC) TSRMLS_CC));
+ if (UNEXPECTED(var_ptr == NULL)) {
+ zend_throw_error(NULL, "Cannot use assign-op operators with overloaded objects nor string offsets");
- zval_dtor(free_op2.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ FREE_OP(free_op_data1);
-static int ZEND_FASTCALL ZEND_IS_SMALLER_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
- zval *result = &EX_T(opline->result.var).tmp_var;
+ HANDLE_EXCEPTION();
+ }
- SAVE_OPLINE();
- ZVAL_BOOL(result, fast_is_smaller_function(result,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC) TSRMLS_CC));
+ if (UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
- zval_dtor(free_op2.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ binary_op(var_ptr, var_ptr, value);
-static int ZEND_FASTCALL ZEND_IS_SMALLER_OR_EQUAL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
- zval *result = &EX_T(opline->result.var).tmp_var;
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+ }
+ }
+ } while (0);
- SAVE_OPLINE();
- ZVAL_BOOL(result, fast_is_smaller_or_equal_function(result,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC) TSRMLS_CC));
+ FREE_OP(free_op_data1);
- zval_dtor(free_op2.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ ZEND_VM_NEXT_OPCODE_EX(1, 2);
}
-static int ZEND_FASTCALL ZEND_BW_OR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_CV(binary_op_type binary_op ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
- zend_free_op free_op2;
+
+ zval *var_ptr;
+ zval *value;
SAVE_OPLINE();
- bitwise_or_function(&EX_T(opline->result.var).tmp_var,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC) TSRMLS_CC);
+ value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var);
+ var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var);
- zval_dtor(free_op2.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+ zend_throw_error(NULL, "Cannot use assign-op operators with overloaded objects nor string offsets");
-static int ZEND_FASTCALL ZEND_BW_AND_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
+ HANDLE_EXCEPTION();
+ }
- SAVE_OPLINE();
- bitwise_and_function(&EX_T(opline->result.var).tmp_var,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC) TSRMLS_CC);
+ if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
- zval_dtor(free_op2.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ binary_op(var_ptr, var_ptr, value);
-static int ZEND_FASTCALL ZEND_BW_XOR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+ }
+ }
- SAVE_OPLINE();
- bitwise_xor_function(&EX_T(opline->result.var).tmp_var,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC) TSRMLS_CC);
- zval_dtor(free_op2.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_BOOL_XOR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || (IS_CV != IS_UNUSED)
USE_OPLINE
- zend_free_op free_op2;
-
- SAVE_OPLINE();
- boolean_xor_function(&EX_T(opline->result.var).tmp_var,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC) TSRMLS_CC);
- zval_dtor(free_op2.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+# if 0 || (IS_CV != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_CV_CV(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_CV(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_CV_CV(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_CV(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || (IS_CV != IS_UNUSED)
USE_OPLINE
- zend_free_op free_op2, free_op_data1;
- zval **object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- zval *object;
- zval *property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC);
- zval *value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- int have_get_ptr = 0;
- if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+# if 0 || (IS_CV != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_CV_CV(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-
- make_real_object(object_ptr TSRMLS_CC);
- object = *object_ptr;
-
- if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to assign property of non-object");
- zval_dtor(free_op2.var);
- FREE_OP(free_op_data1);
-
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
- }
- } else {
- /* here we are sure we are dealing with an object */
- if (1) {
- MAKE_REAL_ZVAL_PTR(property);
- }
-
- /* here property is a string */
- if (opline->extended_value == ZEND_ASSIGN_OBJ
- && Z_OBJ_HT_P(object)->get_property_ptr_ptr) {
- zval **zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- if (zptr != NULL) { /* NULL means no success in getting PTR */
- have_get_ptr = 1;
- if (UNEXPECTED(*zptr == &EG(error_zval))) {
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
- }
- } else {
- SEPARATE_ZVAL_IF_NOT_REF(zptr);
-
- binary_op(*zptr, *zptr, value TSRMLS_CC);
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(*zptr);
- EX_T(opline->result.var).var.ptr = *zptr;
- }
- }
- }
- }
-
- if (!have_get_ptr) {
- zval *z = NULL;
-
- Z_ADDREF_P(object);
- if (opline->extended_value == ZEND_ASSIGN_OBJ) {
- if (Z_OBJ_HT_P(object)->read_property) {
- z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- }
- } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
- if (Z_OBJ_HT_P(object)->read_dimension) {
- z = Z_OBJ_HT_P(object)->read_dimension(object, property, BP_VAR_R TSRMLS_CC);
- }
- }
- if (z) {
- if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
- zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
-
- if (Z_REFCOUNT_P(z) == 0) {
- GC_REMOVE_ZVAL_FROM_BUFFER(z);
- zval_dtor(z);
- FREE_ZVAL(z);
- }
- z = value;
- }
- Z_ADDREF_P(z);
- SEPARATE_ZVAL_IF_NOT_REF(&z);
- binary_op(z, z, value TSRMLS_CC);
- if (opline->extended_value == ZEND_ASSIGN_OBJ) {
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
- Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
- }
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(z);
- EX_T(opline->result.var).var.ptr = z;
- }
- zval_ptr_dtor(&z);
- } else {
- zend_error(E_WARNING, "Attempt to assign property of non-object");
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
- }
- }
- zval_ptr_dtor(&object);
- }
-
- if (1) {
- zval_ptr_dtor(&property);
- } else {
- zval_dtor(free_op2.var);
- }
- FREE_OP(free_op_data1);
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_CV(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_CV_CV(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-
- /* assign_obj has two opcodes! */
- CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_CV(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || (IS_CV != IS_UNUSED)
USE_OPLINE
- zend_free_op free_op2, free_op_data2, free_op_data1;
- zval **var_ptr;
- zval *value;
-
- SAVE_OPLINE();
- switch (opline->extended_value) {
- case ZEND_ASSIGN_OBJ:
- return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- break;
- case ZEND_ASSIGN_DIM: {
- zval **container = _get_zval_ptr_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
-
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- } else if (UNEXPECTED(Z_TYPE_PP(container) == IS_OBJECT)) {
- if (IS_CV == IS_VAR && !0) {
- Z_ADDREF_PP(container); /* undo the effect of get_obj_zval_ptr_ptr() */
- }
- return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else {
- zval *dim = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC);
- zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), container, dim, IS_TMP_VAR, BP_VAR_RW TSRMLS_CC);
- value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- var_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, execute_data, &free_op_data2 TSRMLS_CC);
- }
- }
- break;
- default:
- value = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC);
- var_ptr = _get_zval_ptr_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- /* do nothing */
- break;
+# if 0 || (IS_CV != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_CV_CV(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-
- if (UNEXPECTED(var_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_CV(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_CV_CV(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_CV(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- if (UNEXPECTED(*var_ptr == &EG(error_zval))) {
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
- }
- zval_dtor(free_op2.var);
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || (IS_CV != IS_UNUSED)
+ USE_OPLINE
- CHECK_EXCEPTION();
- if (opline->extended_value == ZEND_ASSIGN_DIM) {
- ZEND_VM_INC_OPCODE();
- }
- ZEND_VM_NEXT_OPCODE();
+# if 0 || (IS_CV != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_CV_CV(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_CV(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_CV_CV(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_CV(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || (IS_CV != IS_UNUSED)
+ USE_OPLINE
- if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
- && Z_OBJ_HANDLER_PP(var_ptr, get)
- && Z_OBJ_HANDLER_PP(var_ptr, set)) {
- /* proxy object */
- zval *objval = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
- Z_ADDREF_P(objval);
- binary_op(objval, objval, value TSRMLS_CC);
- Z_OBJ_HANDLER_PP(var_ptr, set)(var_ptr, objval TSRMLS_CC);
- zval_ptr_dtor(&objval);
- } else {
- binary_op(*var_ptr, *var_ptr, value TSRMLS_CC);
+# if 0 || (IS_CV != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_CV_CV(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(*var_ptr);
- EX_T(opline->result.var).var.ptr = *var_ptr;
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_CV(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_CV_CV(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
- zval_dtor(free_op2.var);
-
- if (opline->extended_value == ZEND_ASSIGN_DIM) {
- FREE_OP(free_op_data1);
- FREE_OP_VAR_PTR(free_op_data2);
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_CV(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
- } else {
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || (IS_CV != IS_UNUSED)
+ USE_OPLINE
- CHECK_EXCEPTION();
+# if 0 || (IS_CV != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_CV_CV(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
- ZEND_VM_NEXT_OPCODE();
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_CV(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_CV_CV(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_CV(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_binary_assign_op_helper_SPEC_CV_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+#if 0 || (IS_CV != IS_UNUSED)
+ USE_OPLINE
-static int ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_binary_assign_op_helper_SPEC_CV_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+# if 0 || (IS_CV != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_CV_CV(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_CV(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_CV_CV(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_CV(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_binary_assign_op_helper_SPEC_CV_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+#if 0 || (IS_CV != IS_UNUSED)
+ USE_OPLINE
-static int ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_binary_assign_op_helper_SPEC_CV_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+# if 0 || (IS_CV != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_CV_CV(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_CV(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_CV_CV(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_CV(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_binary_assign_op_helper_SPEC_CV_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+#if 0 || (IS_CV != IS_UNUSED)
+ USE_OPLINE
-static int ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_binary_assign_op_helper_SPEC_CV_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+# if 0 || (IS_CV != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_CV_CV(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_CV(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_CV_CV(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_CV(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_binary_assign_op_helper_SPEC_CV_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+#if 0 || (IS_CV != IS_UNUSED)
+ USE_OPLINE
-static int ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_binary_assign_op_helper_SPEC_CV_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+# if 0 || (IS_CV != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_CV_CV(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_CV(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_CV_CV(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_CV(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_binary_assign_op_helper_SPEC_CV_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+#if 0 || (IS_CV != IS_UNUSED)
+ USE_OPLINE
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_binary_assign_op_helper_SPEC_CV_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+# if 0 || (IS_CV != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_CV_CV(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_CV(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_CV_CV(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_CV(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_binary_assign_op_helper_SPEC_CV_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+#if 0 || (IS_CV != IS_UNUSED)
+ USE_OPLINE
+
+# if 0 || (IS_CV != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_CV_CV(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_CV(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_CV_CV(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_CV(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_TMP(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_CV(int inc ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
- zend_free_op free_op2;
- zval **object_ptr;
+
zval *object;
zval *property;
- zval **retval;
- int have_get_ptr = 0;
+ zval *zptr;
SAVE_OPLINE();
- object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC);
- retval = &EX_T(opline->result.var).var.ptr;
-
- if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
-
- make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
- object = *object_ptr;
+ object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var);
- if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- zval_dtor(free_op2.var);
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- *retval = &EG(uninitialized_zval);
- }
+ if (IS_CV == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ HANDLE_EXCEPTION();
}
- /* here we are sure we are dealing with an object */
+ property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var);
- if (1) {
- MAKE_REAL_ZVAL_PTR(property);
- }
+ if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot increment/decrement overloaded objects nor string offsets");
- if (Z_OBJ_HT_P(object)->get_property_ptr_ptr) {
- zval **zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- if (zptr != NULL) { /* NULL means no success in getting PTR */
- have_get_ptr = 1;
- if (UNEXPECTED(*zptr == &EG(error_zval))) {
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- *retval = &EG(uninitialized_zval);
- }
- } else {
- SEPARATE_ZVAL_IF_NOT_REF(zptr);
+ HANDLE_EXCEPTION();
+ }
- incdec_op(*zptr);
- if (RETURN_VALUE_USED(opline)) {
- *retval = *zptr;
- PZVAL_LOCK(*retval);
+ do {
+ if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
}
+ break;
}
}
- }
-
- if (!have_get_ptr) {
- if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval *z;
- Z_ADDREF_P(object);
- z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
-
- if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
- zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
+ /* here we are sure we are dealing with an object */
-
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CV == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
-
- if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
- if (inc) {
- fast_long_increment_function(zptr);
- } else {
- fast_long_decrement_function(zptr);
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
-
- if (inc) {
- increment_function(zptr);
++ if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
++ if (inc) {
++ fast_long_increment_function(zptr);
++ } else {
++ fast_long_decrement_function(zptr);
++ }
+ } else {
- decrement_function(zptr);
++ ZVAL_DEREF(zptr);
++ SEPARATE_ZVAL_NOREF(zptr);
+
- if (Z_REFCOUNT_P(z) == 0) {
- GC_REMOVE_ZVAL_FROM_BUFFER(z);
- zval_dtor(z);
- FREE_ZVAL(z);
++ if (inc) {
++ increment_function(zptr);
++ } else {
++ decrement_function(zptr);
++ }
++ }
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_COPY(EX_VAR(opline->result.var), zptr);
}
- }
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), zptr);
- z = value;
}
- Z_ADDREF_P(z);
- SEPARATE_ZVAL_IF_NOT_REF(&z);
- incdec_op(z);
- *retval = z;
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- zval_ptr_dtor(&object);
- SELECTIVE_PZVAL_LOCK(*retval, opline);
- zval_ptr_dtor(&z);
} else {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- *retval = &EG(uninitialized_zval);
- }
+ zend_pre_incdec_overloaded_property(object, property, ((IS_CV == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), inc, (UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL));
}
- }
+ } while (0);
- if (1) {
- zval_ptr_dtor(&property);
- } else {
- zval_dtor(free_op2.var);
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_pre_incdec_property_helper_SPEC_CV_TMP(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_TAIL_CALL(zend_pre_incdec_property_helper_SPEC_CV_CV(1 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_pre_incdec_property_helper_SPEC_CV_TMP(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_TAIL_CALL(zend_pre_incdec_property_helper_SPEC_CV_CV(0 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_TMP(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CV(int inc ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
- zend_free_op free_op2;
- zval **object_ptr;
+
zval *object;
zval *property;
- zval *retval;
- int have_get_ptr = 0;
+ zval *zptr;
SAVE_OPLINE();
- object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2 TSRMLS_CC);
- retval = &EX_T(opline->result.var).tmp_var;
-
- if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
-
- make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
- object = *object_ptr;
+ object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var);
- if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- zval_dtor(free_op2.var);
- ZVAL_NULL(retval);
+ if (IS_CV == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ HANDLE_EXCEPTION();
}
- /* here we are sure we are dealing with an object */
-
- if (1) {
- MAKE_REAL_ZVAL_PTR(property);
- }
+ property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var);
- if (Z_OBJ_HT_P(object)->get_property_ptr_ptr) {
- zval **zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- if (zptr != NULL) { /* NULL means no success in getting PTR */
- have_get_ptr = 1;
- if (UNEXPECTED(*zptr == &EG(error_zval))) {
- ZVAL_NULL(retval);
- } else {
- SEPARATE_ZVAL_IF_NOT_REF(zptr);
+ if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot increment/decrement overloaded objects nor string offsets");
- ZVAL_COPY_VALUE(retval, *zptr);
- zendi_zval_copy_ctor(*retval);
+ HANDLE_EXCEPTION();
+ }
- incdec_op(*zptr);
+ do {
+ if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ break;
}
}
- }
-
- if (!have_get_ptr) {
- if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval *z, *z_copy;
- Z_ADDREF_P(object);
- z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
- zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
+ /* here we are sure we are dealing with an object */
- if (Z_REFCOUNT_P(z) == 0) {
- GC_REMOVE_ZVAL_FROM_BUFFER(z);
- zval_dtor(z);
- FREE_ZVAL(z);
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CV == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
-
- if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
- if (inc) {
- fast_long_increment_function(zptr);
- } else {
- fast_long_decrement_function(zptr);
- }
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
+ } else {
- ZVAL_DEREF(zptr);
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
- zval_opt_copy_ctor(zptr);
- if (inc) {
- increment_function(zptr);
++ if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
++ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
++ if (inc) {
++ fast_long_increment_function(zptr);
++ } else {
++ fast_long_decrement_function(zptr);
++ }
+ } else {
- decrement_function(zptr);
++ ZVAL_DEREF(zptr);
++ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
++ zval_opt_copy_ctor(zptr);
++ if (inc) {
++ increment_function(zptr);
++ } else {
++ decrement_function(zptr);
++ }
}
- z = value;
}
- ZVAL_COPY_VALUE(retval, z);
- zendi_zval_copy_ctor(*retval);
- ALLOC_ZVAL(z_copy);
- INIT_PZVAL_COPY(z_copy, z);
- zendi_zval_copy_ctor(*z_copy);
- incdec_op(z_copy);
- Z_ADDREF_P(z);
- Z_OBJ_HT_P(object)->write_property(object, property, z_copy, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- zval_ptr_dtor(&object);
- zval_ptr_dtor(&z_copy);
- zval_ptr_dtor(&z);
} else {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- ZVAL_NULL(retval);
+ zend_post_incdec_overloaded_property(object, property, ((IS_CV == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), inc, EX_VAR(opline->result.var));
}
- }
+ } while (0);
- if (1) {
- zval_ptr_dtor(&property);
- } else {
- zval_dtor(free_op2.var);
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_post_incdec_property_helper_SPEC_CV_TMP(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_TAIL_CALL(zend_post_incdec_property_helper_SPEC_CV_CV(1 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_post_incdec_property_helper_SPEC_CV_TMP(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_TAIL_CALL(zend_post_incdec_property_helper_SPEC_CV_CV(0 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
+
zval *container;
SAVE_OPLINE();
{
USE_OPLINE
zend_free_op free_op2;
- zval **object_ptr;
- zval *object;
- zval *property;
- zval **retval;
- int have_get_ptr = 0;
+ zval *op1, *op2;
SAVE_OPLINE();
- object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2 TSRMLS_CC);
- retval = &EX_T(opline->result.var).var.ptr;
+ op1 = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var);
+ op2 = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ boolean_xor_function(EX_VAR(opline->result.var), op1, op2);
- if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
+ zval_ptr_dtor_nogc(free_op2);
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
+}
- make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
- object = *object_ptr;
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_TMPVAR(binary_op_type binary_op ZEND_OPCODE_HANDLER_ARGS_DC)
+{
+ USE_OPLINE
+ zend_free_op free_op2, free_op_data1;
+ zval *object;
+ zval *property;
+ zval *value;
+ zval *zptr;
- if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- zval_ptr_dtor_nogc(&free_op2.var);
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- *retval = &EG(uninitialized_zval);
- }
+ SAVE_OPLINE();
+ object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (IS_CV == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
+ zval_ptr_dtor_nogc(EX_VAR(opline->op2.var));
+ HANDLE_EXCEPTION();
}
- /* here we are sure we are dealing with an object */
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (0) {
- MAKE_REAL_ZVAL_PTR(property);
+ if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot use string offset as an object");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
+ zval_ptr_dtor_nogc(free_op2);
+ HANDLE_EXCEPTION();
}
- if (Z_OBJ_HT_P(object)->get_property_ptr_ptr) {
- zval **zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- if (zptr != NULL) { /* NULL means no success in getting PTR */
- have_get_ptr = 1;
- if (UNEXPECTED(*zptr == &EG(error_zval))) {
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- *retval = &EG(uninitialized_zval);
- }
- } else {
- SEPARATE_ZVAL_IF_NOT_REF(zptr);
+ do {
+ value = get_zval_ptr_r((opline+1)->op1_type, (opline+1)->op1, execute_data, &free_op_data1);
- incdec_op(*zptr);
- if (RETURN_VALUE_USED(opline)) {
- *retval = *zptr;
- PZVAL_LOCK(*retval);
+ if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to assign property of non-object");
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
}
+ break;
}
}
- }
- if (!have_get_ptr) {
- if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval *z;
-
- Z_ADDREF_P(object);
- z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
-
- if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
- zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
+ /* here we are sure we are dealing with an object */
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
++ }
++ } else {
++ ZVAL_DEREF(zptr);
++ SEPARATE_ZVAL_NOREF(zptr);
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
-
- binary_op(zptr, zptr, value);
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), zptr);
- if (Z_REFCOUNT_P(z) == 0) {
- GC_REMOVE_ZVAL_FROM_BUFFER(z);
- zval_dtor(z);
- FREE_ZVAL(z);
++ binary_op(zptr, zptr, value);
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_COPY(EX_VAR(opline->result.var), zptr);
+ }
- z = value;
}
- Z_ADDREF_P(z);
- SEPARATE_ZVAL_IF_NOT_REF(&z);
- incdec_op(z);
- *retval = z;
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- zval_ptr_dtor(&object);
- SELECTIVE_PZVAL_LOCK(*retval, opline);
- zval_ptr_dtor(&z);
} else {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- if (RETURN_VALUE_USED(opline)) {
- PZVAL_LOCK(&EG(uninitialized_zval));
- *retval = &EG(uninitialized_zval);
- }
+ zend_assign_op_overloaded_property(object, property, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), value, binary_op, (UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL));
}
- }
-
- if (0) {
- zval_ptr_dtor(&property);
- } else {
- zval_ptr_dtor_nogc(&free_op2.var);
- }
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ } while (0);
-static int ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_pre_incdec_property_helper_SPEC_CV_VAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ FREE_OP(free_op_data1);
+ zval_ptr_dtor_nogc(free_op2);
-static int ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_pre_incdec_property_helper_SPEC_CV_VAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ /* assign_obj has two opcodes! */
+ ZEND_VM_NEXT_OPCODE_EX(1, 2);
}
-static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_VAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_CV_TMPVAR(binary_op_type binary_op ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
- zend_free_op free_op2;
- zval **object_ptr;
- zval *object;
- zval *property;
- zval *retval;
- int have_get_ptr = 0;
+ zend_free_op free_op2, free_op_data1;
+ zval *var_ptr, rv;
+ zval *value, *container, *dim;
SAVE_OPLINE();
- object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2 TSRMLS_CC);
- retval = &EX_T(opline->result.var).tmp_var;
-
- if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
+ container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var);
+ if (IS_CV == IS_UNUSED && UNEXPECTED(Z_OBJ_P(container) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
+ zval_ptr_dtor_nogc(EX_VAR(opline->op2.var));
+ HANDLE_EXCEPTION();
+ }
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_throw_error(NULL, "Cannot use string offset as an array");
+ FREE_UNFETCHED_OP((opline+1)->op1_type, (opline+1)->op1.var);
+ zval_ptr_dtor_nogc(EX_VAR(opline->op2.var));
+ HANDLE_EXCEPTION();
}
- make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
- object = *object_ptr;
+ dim = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- zval_ptr_dtor_nogc(&free_op2.var);
- ZVAL_NULL(retval);
+ do {
+ if (IS_CV == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) != IS_ARRAY)) {
+ if (IS_CV != IS_UNUSED) {
+ ZVAL_DEREF(container);
+ }
+ if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ value = get_zval_ptr_r((opline+1)->op1_type, (opline+1)->op1, execute_data, &free_op_data1);
+ zend_binary_assign_op_obj_dim(container, dim, value, UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL, binary_op);
+ break;
+ }
+ }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
+ zend_fetch_dimension_address_RW(&rv, container, dim, (IS_TMP_VAR|IS_VAR));
+ value = get_zval_ptr_r((opline+1)->op1_type, (opline+1)->op1, execute_data, &free_op_data1);
+ ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+ var_ptr = Z_INDIRECT(rv);
- /* here we are sure we are dealing with an object */
+ if (UNEXPECTED(var_ptr == NULL)) {
+ zend_throw_error(NULL, "Cannot use assign-op operators with overloaded objects nor string offsets");
+ zval_ptr_dtor_nogc(free_op2);
+ FREE_OP(free_op_data1);
- if (0) {
- MAKE_REAL_ZVAL_PTR(property);
- }
+ HANDLE_EXCEPTION();
+ }
- if (Z_OBJ_HT_P(object)->get_property_ptr_ptr) {
- zval **zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- if (zptr != NULL) { /* NULL means no success in getting PTR */
- have_get_ptr = 1;
- if (UNEXPECTED(*zptr == &EG(error_zval))) {
- ZVAL_NULL(retval);
- } else {
- SEPARATE_ZVAL_IF_NOT_REF(zptr);
+ if (UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
- ZVAL_COPY_VALUE(retval, *zptr);
- zendi_zval_copy_ctor(*retval);
+ binary_op(var_ptr, var_ptr, value);
- incdec_op(*zptr);
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
}
}
- }
+ } while (0);
- if (!have_get_ptr) {
- if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval *z, *z_copy;
+ zval_ptr_dtor_nogc(free_op2);
+ FREE_OP(free_op_data1);
- Z_ADDREF_P(object);
- z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
- zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
+ ZEND_VM_NEXT_OPCODE_EX(1, 2);
+}
- if (Z_REFCOUNT_P(z) == 0) {
- GC_REMOVE_ZVAL_FROM_BUFFER(z);
- zval_dtor(z);
- FREE_ZVAL(z);
- }
- z = value;
- }
- ZVAL_COPY_VALUE(retval, z);
- zendi_zval_copy_ctor(*retval);
- ALLOC_ZVAL(z_copy);
- INIT_PZVAL_COPY(z_copy, z);
- zendi_zval_copy_ctor(*z_copy);
- incdec_op(z_copy);
- Z_ADDREF_P(z);
- Z_OBJ_HT_P(object)->write_property(object, property, z_copy, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
- zval_ptr_dtor(&object);
- zval_ptr_dtor(&z_copy);
- zval_ptr_dtor(&z);
- } else {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- ZVAL_NULL(retval);
- }
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_TMPVAR(binary_op_type binary_op ZEND_OPCODE_HANDLER_ARGS_DC)
+{
+ USE_OPLINE
+ zend_free_op free_op2;
+ zval *var_ptr;
+ zval *value;
+
+ SAVE_OPLINE();
+ value = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var);
+
+ if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+ zend_throw_error(NULL, "Cannot use assign-op operators with overloaded objects nor string offsets");
+ zval_ptr_dtor_nogc(free_op2);
+ HANDLE_EXCEPTION();
}
- if (0) {
- zval_ptr_dtor(&property);
+ if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
} else {
- zval_ptr_dtor_nogc(&free_op2.var);
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
+
+ binary_op(var_ptr, var_ptr, value);
+
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+ }
}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ zval_ptr_dtor_nogc(free_op2);
+
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_post_incdec_property_helper_SPEC_CV_VAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
+
+# if 0 || (IS_CV != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_CV_TMPVAR(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_TMPVAR(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_CV_TMPVAR(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_TMPVAR(add_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_post_incdec_property_helper_SPEC_CV_VAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
+
+# if 0 || (IS_CV != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_CV_TMPVAR(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_TMPVAR(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_CV_TMPVAR(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_TMPVAR(sub_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CV_VAR(int type, ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
USE_OPLINE
- zend_free_op free_op1;
- zval *varname;
- zval **retval;
- zval tmp_varname;
- HashTable *target_symbol_table;
- ulong hash_value;
- SAVE_OPLINE();
- varname = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+# if 0 || (IS_CV != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_CV_TMPVAR(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_TMPVAR(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_CV_TMPVAR(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_TMPVAR(mul_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- if (IS_CV != IS_CONST && UNEXPECTED(Z_TYPE_P(varname) != IS_STRING)) {
- ZVAL_COPY_VALUE(&tmp_varname, varname);
- zval_copy_ctor(&tmp_varname);
- Z_SET_REFCOUNT(tmp_varname, 1);
- Z_UNSET_ISREF(tmp_varname);
- convert_to_string(&tmp_varname);
- varname = &tmp_varname;
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
+
+# if 0 || (IS_CV != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_CV_TMPVAR(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_TMPVAR(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_CV_TMPVAR(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_TMPVAR(div_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- if (IS_VAR != IS_UNUSED) {
- zend_class_entry *ce;
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
- if (IS_VAR == IS_CONST) {
- if (CACHED_PTR(opline->op2.literal->cache_slot)) {
- ce = CACHED_PTR(opline->op2.literal->cache_slot);
- } else {
- ce = zend_fetch_class_by_name(Z_STRVAL_P(opline->op2.zv), Z_STRLEN_P(opline->op2.zv), opline->op2.literal + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- if (IS_CV != IS_CONST && varname == &tmp_varname) {
- zval_dtor(&tmp_varname);
- }
+# if 0 || (IS_CV != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_CV_TMPVAR(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_TMPVAR(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_CV_TMPVAR(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_TMPVAR(mod_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
- CACHE_PTR(opline->op2.literal->cache_slot, ce);
- }
- } else {
- ce = EX_T(opline->op2.var).class_entry;
- }
- retval = zend_std_get_static_property(ce, Z_STRVAL_P(varname), Z_STRLEN_P(varname), 0, ((IS_CV == IS_CONST) ? opline->op1.literal : NULL) TSRMLS_CC);
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
- } else {
- target_symbol_table = zend_get_target_symbol_table(opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-/*
- if (!target_symbol_table) {
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-*/
- if (IS_CV == IS_CONST) {
- hash_value = Z_HASH_P(varname);
- } else {
- hash_value = str_hash(Z_STRVAL_P(varname), Z_STRLEN_P(varname));
- }
+# if 0 || (IS_CV != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_CV_TMPVAR(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_TMPVAR(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_CV_TMPVAR(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_TMPVAR(shift_left_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- if (zend_hash_quick_find(target_symbol_table, Z_STRVAL_P(varname), Z_STRLEN_P(varname)+1, hash_value, (void **) &retval) == FAILURE) {
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_UNSET:
- zend_error(E_NOTICE,"Undefined variable: %s", Z_STRVAL_P(varname));
- /* break missing intentionally */
- case BP_VAR_IS:
- retval = &EG(uninitialized_zval_ptr);
- break;
- case BP_VAR_RW:
- zend_error(E_NOTICE,"Undefined variable: %s", Z_STRVAL_P(varname));
- /* break missing intentionally */
- case BP_VAR_W:
- Z_ADDREF_P(&EG(uninitialized_zval));
- zend_hash_quick_update(target_symbol_table, Z_STRVAL_P(varname), Z_STRLEN_P(varname)+1, hash_value, &EG(uninitialized_zval_ptr), sizeof(zval *), (void **) &retval);
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
- }
- }
- switch (opline->extended_value & ZEND_FETCH_TYPE_MASK) {
- case ZEND_FETCH_GLOBAL:
- if (IS_CV != IS_TMP_VAR) {
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
- }
- break;
- case ZEND_FETCH_LOCAL:
+# if 0 || (IS_CV != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_CV_TMPVAR(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_TMPVAR(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_CV_TMPVAR(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_TMPVAR(shift_right_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- break;
- case ZEND_FETCH_STATIC:
- zval_update_constant(retval, 1 TSRMLS_CC);
- break;
- case ZEND_FETCH_GLOBAL_LOCK:
- if (IS_CV == IS_VAR && !free_op1.var) {
- PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
- }
- break;
- }
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
+
+# if 0 || (IS_CV != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_CV_TMPVAR(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_TMPVAR(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_CV_TMPVAR(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_TMPVAR(concat_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
- if (IS_CV != IS_CONST && varname == &tmp_varname) {
- zval_dtor(&tmp_varname);
+# if 0 || (IS_CV != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_CV_TMPVAR(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
- if (opline->extended_value & ZEND_FETCH_MAKE_REF) {
- SEPARATE_ZVAL_TO_MAKE_IS_REF(retval);
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_TMPVAR(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_CV_TMPVAR(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
- PZVAL_LOCK(*retval);
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_IS:
- EX_T(opline->result.var).var.ptr = *retval;
- break;
- case BP_VAR_UNSET: {
- zend_free_op free_res;
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_TMPVAR(bitwise_or_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
- PZVAL_UNLOCK(*retval, &free_res);
- if (retval != &EG(uninitialized_zval_ptr)) {
- SEPARATE_ZVAL_IF_NOT_REF(retval);
- }
- PZVAL_LOCK(*retval);
- FREE_OP_VAR_PTR(free_res);
- }
- /* break missing intentionally */
- default:
- EX_T(opline->result.var).var.ptr_ptr = retval;
- break;
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
+
+# if 0 || (IS_CV != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_CV_TMPVAR(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_TMPVAR(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_CV_TMPVAR(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_TMPVAR(bitwise_and_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
+
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
+
+# if 0 || (IS_CV != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_CV_TMPVAR(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_TMPVAR(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_CV_TMPVAR(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_TMPVAR(bitwise_xor_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
+}
+
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || ((IS_TMP_VAR|IS_VAR) != IS_UNUSED)
+ USE_OPLINE
+
+# if 0 || (IS_CV != IS_UNUSED)
+ if (EXPECTED(opline->extended_value == 0)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_helper_SPEC_CV_TMPVAR(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+# endif
+ if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_TMPVAR(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_obj_helper_SPEC_CV_TMPVAR(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+ }
+#else
+ ZEND_VM_TAIL_CALL(zend_binary_assign_op_dim_helper_SPEC_CV_TMPVAR(pow_function ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
+#endif
}
-static int ZEND_FASTCALL ZEND_FETCH_R_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_TMPVAR(int inc ZEND_OPCODE_HANDLER_ARGS_DC)
{
- return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ USE_OPLINE
+ zend_free_op free_op2;
+ zval *object;
+ zval *property;
+ zval *zptr;
+
+ SAVE_OPLINE();
+ object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var);
+
+ if (IS_CV == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ zval_ptr_dtor_nogc(EX_VAR(opline->op2.var));
+ HANDLE_EXCEPTION();
+ }
+
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+
+ if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot increment/decrement overloaded objects nor string offsets");
+ zval_ptr_dtor_nogc(free_op2);
+ HANDLE_EXCEPTION();
+ }
+
+ do {
+ if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ break;
+ }
+ }
+
+ /* here we are sure we are dealing with an object */
-
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
-
- if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
- if (inc) {
- fast_long_increment_function(zptr);
- } else {
- fast_long_decrement_function(zptr);
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
-
- if (inc) {
- increment_function(zptr);
++ if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
++ if (inc) {
++ fast_long_increment_function(zptr);
++ } else {
++ fast_long_decrement_function(zptr);
++ }
+ } else {
- decrement_function(zptr);
++ ZVAL_DEREF(zptr);
++ SEPARATE_ZVAL_NOREF(zptr);
++
++ if (inc) {
++ increment_function(zptr);
++ } else {
++ decrement_function(zptr);
++ }
++ }
++ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
++ ZVAL_COPY(EX_VAR(opline->result.var), zptr);
+ }
- }
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), zptr);
+ }
+ } else {
+ zend_pre_incdec_overloaded_property(object, property, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), inc, (UNEXPECTED(RETURN_VALUE_USED(opline)) ? EX_VAR(opline->result.var) : NULL));
+ }
+ } while (0);
+
+ zval_ptr_dtor_nogc(free_op2);
+
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_FETCH_W_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_TAIL_CALL(zend_pre_incdec_property_helper_SPEC_CV_TMPVAR(1 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL ZEND_FETCH_RW_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_TAIL_CALL(zend_pre_incdec_property_helper_SPEC_CV_TMPVAR(0 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL ZEND_FETCH_FUNC_ARG_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_TMPVAR(int inc ZEND_OPCODE_HANDLER_ARGS_DC)
{
USE_OPLINE
-
- if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
- if (inc) {
- fast_long_increment_function(zptr);
- } else {
- fast_long_decrement_function(zptr);
- }
+ zend_free_op free_op2;
+ zval *object;
+ zval *property;
+ zval *zptr;
+
+ SAVE_OPLINE();
+ object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var);
+
+ if (IS_CV == IS_UNUSED && UNEXPECTED(Z_OBJ_P(object) == NULL)) {
+ zend_throw_error(NULL, "Using $this when not in object context");
+ zval_ptr_dtor_nogc(EX_VAR(opline->op2.var));
+ HANDLE_EXCEPTION();
+ }
+
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+
+ if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_throw_error(NULL, "Cannot increment/decrement overloaded objects nor string offsets");
+ zval_ptr_dtor_nogc(free_op2);
+ HANDLE_EXCEPTION();
+ }
+
+ do {
+ if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ ZVAL_DEREF(object);
+ if (UNEXPECTED(!make_real_object(object))) {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ break;
+ }
+ }
+
+ /* here we are sure we are dealing with an object */
+
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL))) != NULL)) {
- ZVAL_DEREF(zptr);
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
- zval_opt_copy_ctor(zptr);
- if (inc) {
- increment_function(zptr);
++ if (UNEXPECTED(zptr == &EG(error_zval))) {
++ ZVAL_NULL(EX_VAR(opline->result.var));
+ } else {
- decrement_function(zptr);
++ if (EXPECTED(Z_TYPE_P(zptr) == IS_LONG)) {
++ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
++ if (inc) {
++ fast_long_increment_function(zptr);
++ } else {
++ fast_long_decrement_function(zptr);
++ }
+ } else {
++ ZVAL_DEREF(zptr);
++ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), zptr);
++ zval_opt_copy_ctor(zptr);
++ if (inc) {
++ increment_function(zptr);
++ } else {
++ decrement_function(zptr);
++ }
+ }
+ }
+ } else {
+ zend_post_incdec_overloaded_property(object, property, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? CACHE_ADDR(Z_CACHE_SLOT_P(property)) : NULL), inc, EX_VAR(opline->result.var));
+ }
+ } while (0);
- return zend_fetch_var_address_helper_SPEC_CV_VAR(zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC) ? BP_VAR_W : BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ zval_ptr_dtor_nogc(free_op2);
+
+ ZEND_VM_NEXT_OPCODE_CHECK_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_FETCH_UNSET_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_TAIL_CALL(zend_post_incdec_property_helper_SPEC_CV_TMPVAR(1 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL ZEND_FETCH_IS_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_TAIL_CALL(zend_post_incdec_property_helper_SPEC_CV_TMPVAR(0 ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_CC));
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static ZEND_OPCODE_HANDLER_RET ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op2;