ext/opcache/Optimizer/zend_ssa.c

index ea04a422bcd3e5ba53d28124708538ef7b650e4a..168dbd00debc743941d1f865de1a663e90e0bfa0 100644 (file)
@@ -522,7 +522,7 @@ static int zend_ssa_rename(const zend_op_array *op_array, uint32_t build_flags,
        zend_ssa_op *ssa_ops = ssa->ops;
        int ssa_vars_count = ssa->vars_count;
        int i, j;
-       zend_op *opline, *end;
+       zend_op *opline, *end, *next;
        int *tmp = NULL;
        ALLOCA_FLAG(use_heap = 0);
 
@@ -552,40 +552,27 @@ static int zend_ssa_rename(const zend_op_array *op_array, uint32_t build_flags,
        for (; opline < end; opline++) {
                uint32_t k = opline - op_array->opcodes;
                if (opline->opcode != ZEND_OP_DATA) {
-                       zend_op *next = opline + 1;
-                       if (next < end && next->opcode == ZEND_OP_DATA) {
-                               if (next->op1_type == IS_CV) {
-                                       ssa_ops[k + 1].op1_use = var[EX_VAR_TO_NUM(next->op1.var)];
-                                       //USE_SSA_VAR(next->op1.var);
-                               } else if (next->op1_type & (IS_VAR|IS_TMP_VAR)) {
-                                       ssa_ops[k + 1].op1_use = var[EX_VAR_TO_NUM(next->op1.var)];
-                                       //USE_SSA_VAR(op_array->last_var + next->op1.var);
-                               }
-                               if (next->op2_type == IS_CV) {
-                                       ssa_ops[k + 1].op2_use = var[EX_VAR_TO_NUM(next->op2.var)];
-                                       //USE_SSA_VAR(next->op2.var);
-                               } else if (next->op2_type & (IS_VAR|IS_TMP_VAR)) {
-                                       ssa_ops[k + 1].op2_use = var[EX_VAR_TO_NUM(next->op2.var)];
-                                       //USE_SSA_VAR(op_array->last_var + next->op2.var);
-                               }
-                       }
+
                        if (opline->op1_type & (IS_CV|IS_VAR|IS_TMP_VAR)) {
                                ssa_ops[k].op1_use = var[EX_VAR_TO_NUM(opline->op1.var)];
                                //USE_SSA_VAR(op_array->last_var + opline->op1.var)
                        }
-                       if (opline->opcode == ZEND_FE_FETCH_R || opline->opcode == ZEND_FE_FETCH_RW) {
-                               if (opline->op2_type == IS_CV) {
-                                       ssa_ops[k].op2_use = var[EX_VAR_TO_NUM(opline->op2.var)];
-                               }
-                               ssa_ops[k].op2_def = ssa_vars_count;
-                               var[EX_VAR_TO_NUM(opline->op2.var)] = ssa_vars_count;
-                               ssa_vars_count++;
-                               //NEW_SSA_VAR(opline->op2.var)
-                       } else if (opline->op2_type & (IS_CV|IS_VAR|IS_TMP_VAR)) {
+                       if (opline->op2_type & (IS_CV|IS_VAR|IS_TMP_VAR)) {
                                ssa_ops[k].op2_use = var[EX_VAR_TO_NUM(opline->op2.var)];
                                //USE_SSA_VAR(op_array->last_var + opline->op2.var)
                        }
+                       if ((build_flags & ZEND_SSA_USE_CV_RESULTS)
+                        && opline->result_type == IS_CV
+                        && opline->opcode != ZEND_RECV) {
+                               ssa_ops[k].result_use = var[EX_VAR_TO_NUM(opline->result.var)];
+                               //USE_SSA_VAR(op_array->last_var + opline->result.var)
+                       }
+
                        switch (opline->opcode) {
+                               case ZEND_ADD_ARRAY_UNPACK:
+                               case ZEND_ADD_ARRAY_ELEMENT:
+                                       ssa_ops[k].result_use = var[EX_VAR_TO_NUM(opline->result.var)];
+                                       break;
                                case ZEND_ASSIGN:
                                        if ((build_flags & ZEND_SSA_RC_INFERENCE) && opline->op2_type == IS_CV) {
                                                ssa_ops[k].op2_def = ssa_vars_count;
@@ -594,6 +581,7 @@ static int zend_ssa_rename(const zend_op_array *op_array, uint32_t build_flags,
                                                //NEW_SSA_VAR(opline->op2.var)
                                        }
                                        if (opline->op1_type == IS_CV) {
+add_op1_def:
                                                ssa_ops[k].op1_def = ssa_vars_count;
                                                var[EX_VAR_TO_NUM(opline->op1.var)] = ssa_vars_count;
                                                ssa_vars_count++;
@@ -601,7 +589,6 @@ static int zend_ssa_rename(const zend_op_array *op_array, uint32_t build_flags,
                                        }
                                        break;
                                case ZEND_ASSIGN_REF:
-//TODO: ???
                                        if (opline->op2_type == IS_CV) {
                                                ssa_ops[k].op2_def = ssa_vars_count;
                                                var[EX_VAR_TO_NUM(opline->op2.var)] = ssa_vars_count;
@@ -609,90 +596,95 @@ static int zend_ssa_rename(const zend_op_array *op_array, uint32_t build_flags,
                                                //NEW_SSA_VAR(opline->op2.var)
                                        }
                                        if (opline->op1_type == IS_CV) {
-                                               ssa_ops[k].op1_def = ssa_vars_count;
-                                               var[EX_VAR_TO_NUM(opline->op1.var)] = ssa_vars_count;
-                                               ssa_vars_count++;
-                                               //NEW_SSA_VAR(opline->op1.var)
-                                       }
-                                       break;
-                               case ZEND_BIND_GLOBAL:
-                               case ZEND_BIND_STATIC:
-                                       if (opline->op1_type == IS_CV) {
-                                               ssa_ops[k].op1_def = ssa_vars_count;
-                                               var[EX_VAR_TO_NUM(opline->op1.var)] = ssa_vars_count;
-                                               ssa_vars_count++;
-                                               //NEW_SSA_VAR(opline->op1.var)
+                                               goto add_op1_def;
                                        }
                                        break;
                                case ZEND_ASSIGN_DIM:
                                case ZEND_ASSIGN_OBJ:
-                                       if (opline->op1_type == IS_CV) {
-                                               ssa_ops[k].op1_def = ssa_vars_count;
-                                               var[EX_VAR_TO_NUM(opline->op1.var)] = ssa_vars_count;
-                                               ssa_vars_count++;
-                                               //NEW_SSA_VAR(opline->op1.var)
+                                       next = opline + 1;
+                                       if (next->op1_type & (IS_CV|IS_VAR|IS_TMP_VAR)) {
+                                               ssa_ops[k + 1].op1_use = var[EX_VAR_TO_NUM(next->op1.var)];
+                                               //USE_SSA_VAR(op_array->last_var + next->op1.var);
+                                               if (build_flags & ZEND_SSA_RC_INFERENCE && next->op1_type == IS_CV) {
+                                                       ssa_ops[k + 1].op1_def = ssa_vars_count;
+                                                       var[EX_VAR_TO_NUM(next->op1.var)] = ssa_vars_count;
+                                                       ssa_vars_count++;
+                                                       //NEW_SSA_VAR(next->op1.var)
+                                               }
                                        }
-                                       if ((build_flags & ZEND_SSA_RC_INFERENCE) && next->op1_type == IS_CV) {
-                                               ssa_ops[k + 1].op1_def = ssa_vars_count;
-                                               var[EX_VAR_TO_NUM(next->op1.var)] = ssa_vars_count;
-                                               ssa_vars_count++;
-                                               //NEW_SSA_VAR(next->op1.var)
+                                       if (opline->op1_type == IS_CV) {
+                                               goto add_op1_def;
                                        }
                                        break;
                                case ZEND_ASSIGN_OBJ_REF:
-                                       if (opline->op1_type == IS_CV) {
-                                               ssa_ops[k].op1_def = ssa_vars_count;
-                                               var[EX_VAR_TO_NUM(opline->op1.var)] = ssa_vars_count;
-                                               ssa_vars_count++;
-                                               //NEW_SSA_VAR(opline->op1.var)
+                                       next = opline + 1;
+                                       if (next->op1_type & (IS_CV|IS_VAR|IS_TMP_VAR)) {
+                                               ssa_ops[k + 1].op1_use = var[EX_VAR_TO_NUM(next->op1.var)];
+                                               //USE_SSA_VAR(op_array->last_var + next->op1.var);
+                                               if (next->op1_type == IS_CV) {
+                                                       ssa_ops[k + 1].op1_def = ssa_vars_count;
+                                                       var[EX_VAR_TO_NUM(next->op1.var)] = ssa_vars_count;
+                                                       ssa_vars_count++;
+                                                       //NEW_SSA_VAR(next->op1.var)
+                                               }
                                        }
-                                       /* break missing intentionally */
-                               case ZEND_ASSIGN_STATIC_PROP_REF:
-                                       if (next->op1_type == IS_CV) {
-                                               ssa_ops[k + 1].op1_def = ssa_vars_count;
-                                               var[EX_VAR_TO_NUM(next->op1.var)] = ssa_vars_count;
-                                               ssa_vars_count++;
-                                               //NEW_SSA_VAR(next->op1.var)
+                                       if (opline->op1_type == IS_CV) {
+                                               goto add_op1_def;
                                        }
                                        break;
-                               case ZEND_PRE_INC_OBJ:
-                               case ZEND_PRE_DEC_OBJ:
-                               case ZEND_POST_INC_OBJ:
-                               case ZEND_POST_DEC_OBJ:
-                                       if (opline->op1_type == IS_CV) {
-                                               ssa_ops[k].op1_def = ssa_vars_count;
-                                               var[EX_VAR_TO_NUM(opline->op1.var)] = ssa_vars_count;
-                                               ssa_vars_count++;
-                                               //NEW_SSA_VAR(opline->op1.var)
+                               case ZEND_ASSIGN_STATIC_PROP:
+                                       next = opline + 1;
+                                       if (next->op1_type & (IS_CV|IS_VAR|IS_TMP_VAR)) {
+                                               ssa_ops[k + 1].op1_use = var[EX_VAR_TO_NUM(next->op1.var)];
+                                               //USE_SSA_VAR(op_array->last_var + next->op1.var);
+#if 0
+                                               if ((build_flags & ZEND_SSA_RC_INFERENCE) && next->op1_type == IS_CV) {
+                                                       ssa_ops[k + 1].op1_def = ssa_vars_count;
+                                                       var[EX_VAR_TO_NUM(next->op1.var)] = ssa_vars_count;
+                                                       ssa_vars_count++;
+                                                       //NEW_SSA_VAR(next->op1.var)
+                                               }
+#endif
                                        }
                                        break;
-                               case ZEND_ADD_ARRAY_ELEMENT:
-                                       ssa_ops[k].result_use = var[EX_VAR_TO_NUM(opline->result.var)];
-                               case ZEND_INIT_ARRAY:
-                                       if (((build_flags & ZEND_SSA_RC_INFERENCE)
-                                                               || (opline->extended_value & ZEND_ARRAY_ELEMENT_REF))
-                                                       && opline->op1_type == IS_CV) {
-                                               ssa_ops[k].op1_def = ssa_vars_count;
-                                               var[EX_VAR_TO_NUM(opline->op1.var)] = ssa_vars_count;
-                                               ssa_vars_count++;
-                                               //NEW_SSA_VAR(opline+->op1.var)
+                               case ZEND_ASSIGN_STATIC_PROP_REF:
+                                       next = opline + 1;
+                                       if (next->op1_type & (IS_CV|IS_VAR|IS_TMP_VAR)) {
+                                               ssa_ops[k + 1].op1_use = var[EX_VAR_TO_NUM(next->op1.var)];
+                                               //USE_SSA_VAR(op_array->last_var + next->op1.var);
+                                               if (next->op1_type == IS_CV) {
+                                                       ssa_ops[k + 1].op1_def = ssa_vars_count;
+                                                       var[EX_VAR_TO_NUM(next->op1.var)] = ssa_vars_count;
+                                                       ssa_vars_count++;
+                                                       //NEW_SSA_VAR(next->op1.var)
+                                               }
                                        }
                                        break;
-                               case ZEND_ADD_ARRAY_UNPACK:
-                                       ssa_ops[k].result_use = var[EX_VAR_TO_NUM(opline->result.var)];
+                               case ZEND_ASSIGN_STATIC_PROP_OP:
+                                       next = opline + 1;
+                                       if (next->op1_type & (IS_CV|IS_VAR|IS_TMP_VAR)) {
+                                               ssa_ops[k + 1].op1_use = var[EX_VAR_TO_NUM(next->op1.var)];
+                                               //USE_SSA_VAR(op_array->last_var + next->op1.var);
+                                       }
                                        break;
-                               case ZEND_SEND_VAR:
-                               case ZEND_CAST:
-                               case ZEND_QM_ASSIGN:
-                               case ZEND_JMP_SET:
-                               case ZEND_COALESCE:
-                                       if ((build_flags & ZEND_SSA_RC_INFERENCE) && opline->op1_type == IS_CV) {
-                                               ssa_ops[k].op1_def = ssa_vars_count;
-                                               var[EX_VAR_TO_NUM(opline->op1.var)] = ssa_vars_count;
-                                               ssa_vars_count++;
-                                               //NEW_SSA_VAR(opline->op1.var)
+                               case ZEND_ASSIGN_DIM_OP:
+                               case ZEND_ASSIGN_OBJ_OP:
+                                       next = opline + 1;
+                                       if (next->op1_type & (IS_CV|IS_VAR|IS_TMP_VAR)) {
+                                               ssa_ops[k + 1].op1_use = var[EX_VAR_TO_NUM(next->op1.var)];
+                                               //USE_SSA_VAR(op_array->last_var + next->op1.var);
+                                       }
+                                       if (opline->op1_type == IS_CV) {
+                                               goto add_op1_def;
                                        }
                                        break;
+                               case ZEND_ASSIGN_OP:
+                               case ZEND_PRE_INC:
+                               case ZEND_PRE_DEC:
+                               case ZEND_POST_INC:
+                               case ZEND_POST_DEC:
+                               case ZEND_BIND_GLOBAL:
+                               case ZEND_BIND_STATIC:
                                case ZEND_SEND_VAR_NO_REF:
                                case ZEND_SEND_VAR_NO_REF_EX:
                                case ZEND_SEND_VAR_EX:
@@ -701,41 +693,10 @@ static int zend_ssa_rename(const zend_op_array *op_array, uint32_t build_flags,
                                case ZEND_SEND_UNPACK:
                                case ZEND_FE_RESET_RW:
                                case ZEND_MAKE_REF:
-                                       if (opline->op1_type == IS_CV) {
-                                               ssa_ops[k].op1_def = ssa_vars_count;
-                                               var[EX_VAR_TO_NUM(opline->op1.var)] = ssa_vars_count;
-                                               ssa_vars_count++;
-                                               //NEW_SSA_VAR(opline->op1.var)
-                                       }
-                                       break;
-                               case ZEND_FE_RESET_R:
-                                       if ((build_flags & ZEND_SSA_RC_INFERENCE) && opline->op1_type == IS_CV) {
-                                               ssa_ops[k].op1_def = ssa_vars_count;
-                                               var[EX_VAR_TO_NUM(opline->op1.var)] = ssa_vars_count;
-                                               ssa_vars_count++;
-                                               //NEW_SSA_VAR(opline->op1.var)
-                                       }
-                                       break;
-                               case ZEND_ASSIGN_OP:
-                               case ZEND_ASSIGN_DIM_OP:
-                               case ZEND_ASSIGN_OBJ_OP:
-                               case ZEND_ASSIGN_STATIC_PROP_OP:
-                               case ZEND_PRE_INC:
-                               case ZEND_PRE_DEC:
-                               case ZEND_POST_INC:
-                               case ZEND_POST_DEC:
-                                       if (opline->op1_type == IS_CV) {
-                                               ssa_ops[k].op1_def = ssa_vars_count;
-                                               var[EX_VAR_TO_NUM(opline->op1.var)] = ssa_vars_count;
-                                               ssa_vars_count++;
-                                               //NEW_SSA_VAR(opline->op1.var)
-                                       }
-                                       break;
-                               case ZEND_UNSET_CV:
-                                       ssa_ops[k].op1_def = ssa_vars_count;
-                                       var[EX_VAR_TO_NUM(opline->op1.var)] = ssa_vars_count;
-                                       ssa_vars_count++;
-                                       break;
+                               case ZEND_PRE_INC_OBJ:
+                               case ZEND_PRE_DEC_OBJ:
+                               case ZEND_POST_INC_OBJ:
+                               case ZEND_POST_DEC_OBJ:
                                case ZEND_UNSET_DIM:
                                case ZEND_UNSET_OBJ:
                                case ZEND_FETCH_DIM_W:
@@ -744,49 +705,63 @@ static int zend_ssa_rename(const zend_op_array *op_array, uint32_t build_flags,
                                case ZEND_FETCH_DIM_UNSET:
                                case ZEND_FETCH_LIST_W:
                                        if (opline->op1_type == IS_CV) {
-                                               ssa_ops[k].op1_def = ssa_vars_count;
-                                               var[EX_VAR_TO_NUM(opline->op1.var)] = ssa_vars_count;
-                                               ssa_vars_count++;
-                                               //NEW_SSA_VAR(opline->op1.var)
+                                               goto add_op1_def;
                                        }
                                        break;
-                               case ZEND_BIND_LEXICAL:
-                                       if ((opline->extended_value & ZEND_BIND_REF) || (build_flags & ZEND_SSA_RC_INFERENCE)) {
-                                               ssa_ops[k].op2_def = ssa_vars_count;
-                                               var[EX_VAR_TO_NUM(opline->op2.var)] = ssa_vars_count;
-                                               ssa_vars_count++;
+                               case ZEND_SEND_VAR:
+                               case ZEND_CAST:
+                               case ZEND_QM_ASSIGN:
+                               case ZEND_JMP_SET:
+                               case ZEND_COALESCE:
+                               case ZEND_FE_RESET_R:
+                                       if ((build_flags & ZEND_SSA_RC_INFERENCE) && opline->op1_type == IS_CV) {
+                                               goto add_op1_def;
+                                       }
+                                       break;
+                               case ZEND_INIT_ARRAY:
+                                       if (((build_flags & ZEND_SSA_RC_INFERENCE)
+                                                               || (opline->extended_value & ZEND_ARRAY_ELEMENT_REF))
+                                                       && opline->op1_type == IS_CV) {
+                                               goto add_op1_def;
                                        }
                                        break;
                                case ZEND_YIELD:
                                        if (opline->op1_type == IS_CV
                                                        && ((op_array->fn_flags & ZEND_ACC_RETURN_REFERENCE)
                                                                || (build_flags & ZEND_SSA_RC_INFERENCE))) {
-                                               ssa_ops[k].op1_def = ssa_vars_count;
-                                               var[EX_VAR_TO_NUM(opline->op1.var)] = ssa_vars_count;
-                                               ssa_vars_count++;
+                                               goto add_op1_def;
                                        }
                                        break;
+                               case ZEND_UNSET_CV:
+                                       goto add_op1_def;
                                case ZEND_VERIFY_RETURN_TYPE:
                                        if (opline->op1_type & (IS_TMP_VAR|IS_VAR|IS_CV)) {
-                                               ssa_ops[k].op1_def = ssa_vars_count;
-                                               var[EX_VAR_TO_NUM(opline->op1.var)] = ssa_vars_count;
+                                               goto add_op1_def;
+                                       }
+                                       break;
+                               case ZEND_FE_FETCH_R:
+                               case ZEND_FE_FETCH_RW:
+                                       if (opline->op2_type != IS_CV) {
+                                               ssa_ops[k].op2_use = -1; /* not used */
+                                       }
+                                       ssa_ops[k].op2_def = ssa_vars_count;
+                                       var[EX_VAR_TO_NUM(opline->op2.var)] = ssa_vars_count;
+                                       ssa_vars_count++;
+                                       //NEW_SSA_VAR(opline->op2.var)
+                                       break;
+                               case ZEND_BIND_LEXICAL:
+                                       if ((opline->extended_value & ZEND_BIND_REF) || (build_flags & ZEND_SSA_RC_INFERENCE)) {
+                                               ssa_ops[k].op2_def = ssa_vars_count;
+                                               var[EX_VAR_TO_NUM(opline->op2.var)] = ssa_vars_count;
                                                ssa_vars_count++;
-                                               //NEW_SSA_VAR(opline->op1.var)
+                                               //NEW_SSA_VAR(opline->op2.var)
                                        }
                                        break;
                                default:
                                        break;
                        }
-                       if (opline->result_type == IS_CV) {
-                               if ((build_flags & ZEND_SSA_USE_CV_RESULTS)
-                                && opline->opcode != ZEND_RECV) {
-                                       ssa_ops[k].result_use = var[EX_VAR_TO_NUM(opline->result.var)];
-                               }
-                               ssa_ops[k].result_def = ssa_vars_count;
-                               var[EX_VAR_TO_NUM(opline->result.var)] = ssa_vars_count;
-                               ssa_vars_count++;
-                               //NEW_SSA_VAR(opline->result.var)
-                       } else if (opline->result_type & (IS_VAR|IS_TMP_VAR)) {
+
+                       if (opline->result_type & (IS_CV|IS_VAR|IS_TMP_VAR)) {
                                ssa_ops[k].result_def = ssa_vars_count;
                                var[EX_VAR_TO_NUM(opline->result.var)] = ssa_vars_count;
                                ssa_vars_count++;