result = 0;
if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
- if (IS_CONST == IS_CV || IS_CONST == IS_VAR) {
+ if (IS_CONST & (IS_CV|IS_VAR)) {
ZVAL_DEREF(offset);
}
if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INIT_USER_CALL_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
- zval *container;
zend_free_op free_op2;
- zval *offset;
-
- SAVE_OPLINE();
- container = opline->op1.zv;
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-
- if ((IS_CONST != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
- UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
- zend_error(E_NOTICE, "Trying to get property of non-object");
- ZVAL_NULL(EX_VAR(opline->result.var));
- } else {
- zval *retval;
-
- /* here we are sure we are dealing with an object */
- do {
- if (IS_TMP_VAR == IS_CONST &&
- EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
- zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
- zend_object *zobj = Z_OBJ_P(container);
-
- if (EXPECTED(prop_info)) {
- retval = OBJ_PROP(zobj, prop_info->offset);
- if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- } else if (EXPECTED(zobj->properties != NULL)) {
- retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
- if (EXPECTED(retval)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- }
- }
-
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+ zval *function_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ zend_fcall_info_cache fcc;
+ char *error = NULL;
+ zend_function *func;
+ zend_class_entry *called_scope;
+ zend_object *object;
- if (retval != EX_VAR(opline->result.var)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ if (zend_is_callable_ex(function_name, NULL, 0, NULL, &fcc, &error TSRMLS_CC)) {
+ if (error) {
+ efree(error);
+ }
+ func = fcc.function_handler;
+ if (func->common.fn_flags & ZEND_ACC_CLOSURE) {
+ /* Delay closure destruction until its invocation */
+ func->common.prototype = (zend_function*)Z_OBJ_P(function_name);
+ Z_ADDREF_P(function_name);
+ }
+ called_scope = fcc.called_scope;
+ object = fcc.object;
+ if (object) {
+ GC_REFCOUNT(object)++; /* For $this pointer */
+ } else if (func->common.scope &&
+ !(func->common.fn_flags & ZEND_ACC_STATIC)) {
+ if (func->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
+ zend_error(E_STRICT,
+ "Non-static method %s::%s() should not be called statically",
+ func->common.scope->name->val, func->common.function_name->val);
+ } else {
+ zend_error_noreturn(
+ E_ERROR,
+ "Non-static method %s::%s() cannot be called statically",
+ func->common.scope->name->val, func->common.function_name->val);
}
- } while (0);
+ }
+ } else {
+ zend_error(E_WARNING, "%s() expects parameter 1 to be a valid callback, %s", Z_STRVAL_P(opline->op1.zv), error);
+ efree(error);
+ func = (zend_function*)&zend_pass_function;
+ called_scope = NULL;
+ object = NULL;
}
- zval_ptr_dtor_nogc(free_op2);
+ EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
+ func, opline->extended_value, called_scope, object, EX(call) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_YIELD_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *container;
- zend_free_op free_op2;
- zval *offset;
-
- SAVE_OPLINE();
- container = opline->op1.zv;
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-
- if ((IS_CONST != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
- UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- } else {
- zval *retval;
+ /* The generator object is stored in EX(return_value) */
+ zend_generator *generator = (zend_generator *) EX(return_value);
- /* here we are sure we are dealing with an object */
- do {
- if (IS_TMP_VAR == IS_CONST &&
- EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
- zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
- zend_object *zobj = Z_OBJ_P(container);
+ if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
+ zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
+ }
- if (EXPECTED(prop_info)) {
- retval = OBJ_PROP(zobj, prop_info->offset);
- if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- } else if (EXPECTED(zobj->properties != NULL)) {
- retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
- if (EXPECTED(retval)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- }
- }
+ /* Destroy the previously yielded value */
+ zval_ptr_dtor(&generator->value);
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+ /* Destroy the previously yielded key */
+ zval_ptr_dtor(&generator->key);
- if (retval != EX_VAR(opline->result.var)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- }
- } while (0);
- }
+ /* Set the new yielded value */
+ if (IS_CONST != IS_UNUSED) {
- zval_ptr_dtor_nogc(free_op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
+ /* Constants and temporary variables aren't yieldable by reference,
+ * but we still allow them with a notice. */
+ if (IS_CONST == IS_CONST || IS_CONST == IS_TMP_VAR) {
+ zval *value;
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *container;
+ zend_error(E_NOTICE, "Only variable references should be yielded by reference");
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- /* Behave like FETCH_OBJ_W */
- zend_free_op free_op1, free_op2;
- zval *property;
+ value = opline->op1.zv;
+ ZVAL_COPY_VALUE(&generator->value, value);
+ if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
- SAVE_OPLINE();
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- container = NULL;
+ /* Temporary variables don't need ctor copying */
+ if (IS_CONST != IS_TMP_VAR) {
+ zval_opt_copy_ctor(&generator->value);
+ }
+ } else {
+ zval *value_ptr = NULL;
- if (IS_CONST == IS_CONST || IS_CONST == IS_TMP_VAR) {
- zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
- }
- if (IS_CONST == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CONST, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- if (IS_CONST == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
+ if (IS_CONST == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
+ }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- } else {
- return ZEND_FETCH_OBJ_R_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
+ /* If a function call result is yielded and the function did
+ * not return by reference we throw a notice. */
+ if (IS_CONST == IS_VAR &&
+ (value_ptr == &EG(uninitialized_zval) ||
+ (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+ !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+ zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+ } else {
+ ZVAL_MAKE_REF(value_ptr);
+ }
+ ZVAL_COPY(&generator->value, value_ptr);
-static int ZEND_FASTCALL ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *function_name;
- zend_class_entry *ce;
- zend_object *object;
- zend_function *fbc;
+ }
+ } else {
+ zval *value = opline->op1.zv;
- SAVE_OPLINE();
+ /* Consts, temporary variables and references need copying */
+ if (IS_CONST == IS_CONST) {
+ ZVAL_DUP(&generator->value, value);
+ } else if (IS_CONST == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&generator->value, value);
+ } else if ((IS_CONST == IS_CV || IS_CONST == IS_VAR) && Z_ISREF_P(value)) {
+ ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
- if (IS_CONST == IS_CONST) {
- /* no function found. try a static method in class */
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op1.zv), opline->op1.zv + 1, ZEND_FETCH_CLASS_DEFAULT TSRMLS_CC);
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- if (UNEXPECTED(ce == NULL)) {
- zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
+ } else {
+ ZVAL_COPY_VALUE(&generator->value, value);
+ if (IS_CONST == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+ }
}
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op1.zv), ce);
}
} else {
- ce = Z_CE_P(EX_VAR(opline->op1.var));
+ /* If no value was specified yield null */
+ ZVAL_NULL(&generator->value);
}
- if (IS_CONST == IS_CONST &&
- IS_TMP_VAR == IS_CONST &&
- CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- fbc = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else if (IS_CONST != IS_CONST &&
- IS_TMP_VAR == IS_CONST &&
- (fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce))) {
- /* do nothing */
- } else if (IS_TMP_VAR != IS_UNUSED) {
+ /* Set the new yielded key */
+ if (IS_TMP_VAR != IS_UNUSED) {
zend_free_op free_op2;
+ zval *key = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- function_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- if (IS_TMP_VAR != IS_CONST) {
- if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- zend_error_noreturn(E_ERROR, "Function name must be a string");
- }
- }
+ /* Consts, temporary variables and references need copying */
+ if (IS_TMP_VAR == IS_CONST) {
+ ZVAL_DUP(&generator->key, key);
+ } else if (IS_TMP_VAR == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&generator->key, key);
+ } else if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && Z_ISREF_P(key)) {
+ ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
- if (ce->get_static_method) {
- fbc = ce->get_static_method(ce, Z_STR_P(function_name) TSRMLS_CC);
} else {
- fbc = zend_std_get_static_method(ce, Z_STR_P(function_name), ((IS_TMP_VAR == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
- }
- if (UNEXPECTED(fbc == NULL)) {
- zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name->val, Z_STRVAL_P(function_name));
- }
- if (IS_TMP_VAR == IS_CONST &&
- EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
- EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0)) {
- if (IS_CONST == IS_CONST) {
- CACHE_PTR(Z_CACHE_SLOT_P(function_name), fbc);
- } else {
- CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), ce, fbc);
+ ZVAL_COPY_VALUE(&generator->key, key);
+ if (IS_TMP_VAR == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
}
}
- if (IS_TMP_VAR != IS_CONST) {
- zval_ptr_dtor_nogc(free_op2);
- }
- } else {
- if (UNEXPECTED(ce->constructor == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot call constructor");
- }
- if (Z_OBJ(EX(This)) && Z_OBJ(EX(This))->ce != ce->constructor->common.scope && (ce->constructor->common.fn_flags & ZEND_ACC_PRIVATE)) {
- zend_error_noreturn(E_ERROR, "Cannot call private %s::__construct()", ce->name->val);
- }
- fbc = ce->constructor;
- }
- object = NULL;
- if (!(fbc->common.fn_flags & ZEND_ACC_STATIC)) {
- if (Z_OBJ(EX(This))) {
- object = Z_OBJ(EX(This));
- GC_REFCOUNT(object)++;
- }
- if (!object ||
- !instanceof_function(object->ce, ce TSRMLS_CC)) {
- /* We are calling method of the other (incompatible) class,
- but passing $this. This is done for compatibility with php-4. */
- if (fbc->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
- zend_error(
- object ? E_DEPRECATED : E_STRICT,
- "Non-static method %s::%s() should not be called statically%s",
- fbc->common.scope->name->val, fbc->common.function_name->val,
- object ? ", assuming $this from incompatible context" : "");
- } else {
- /* An internal function assumes $this is present and won't check that. So PHP would crash by allowing the call. */
- zend_error_noreturn(
- E_ERROR,
- "Non-static method %s::%s() cannot be called statically%s",
- fbc->common.scope->name->val, fbc->common.function_name->val,
- object ? ", assuming $this from incompatible context" : "");
- }
+ if (Z_TYPE(generator->key) == IS_LONG
+ && Z_LVAL(generator->key) > generator->largest_used_integer_key
+ ) {
+ generator->largest_used_integer_key = Z_LVAL(generator->key);
}
+ } else {
+ /* If no key was specified we use auto-increment keys */
+ generator->largest_used_integer_key++;
+ ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
}
- if (IS_CONST != IS_CONST) {
- /* previous opcode is ZEND_FETCH_CLASS */
- if ((opline-1)->extended_value == ZEND_FETCH_CLASS_PARENT || (opline-1)->extended_value == ZEND_FETCH_CLASS_SELF) {
- ce = EX(called_scope);
- }
+ if (RETURN_VALUE_USED(opline)) {
+ /* If the return value of yield is used set the send
+ * target and initialize it to NULL */
+ generator->send_target = EX_VAR(opline->result.var);
+ ZVAL_NULL(generator->send_target);
+ } else {
+ generator->send_target = NULL;
}
- EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
- fbc, opline->extended_value, ce, object, EX(call) TSRMLS_CC);
+ /* We increment to the next op, so we are at the correct position when the
+ * generator is resumed. */
+ ZEND_VM_INC_OPCODE();
- if (IS_TMP_VAR == IS_UNUSED) {
- EX(call)->return_value = NULL;
- }
+ /* The GOTO VM uses a local opline variable. We need to set the opline
+ * variable in execute_data so we don't resume at an old position. */
+ SAVE_OPLINE();
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ ZEND_VM_RETURN();
}
-static int ZEND_FASTCALL ZEND_INIT_USER_CALL_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_POW_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op2;
- zval *function_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- zend_fcall_info_cache fcc;
- char *error = NULL;
- zend_function *func;
- zend_class_entry *called_scope;
- zend_object *object;
-
- if (zend_is_callable_ex(function_name, NULL, 0, NULL, &fcc, &error TSRMLS_CC)) {
- if (error) {
- efree(error);
- }
- func = fcc.function_handler;
- if (func->common.fn_flags & ZEND_ACC_CLOSURE) {
- /* Delay closure destruction until its invocation */
- func->common.prototype = (zend_function*)Z_OBJ_P(function_name);
- Z_ADDREF_P(function_name);
- }
- called_scope = fcc.called_scope;
- object = fcc.object;
- if (object) {
- GC_REFCOUNT(object)++; /* For $this pointer */
- } else if (func->common.scope &&
- !(func->common.fn_flags & ZEND_ACC_STATIC)) {
- if (func->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
- zend_error(E_STRICT,
- "Non-static method %s::%s() should not be called statically",
- func->common.scope->name->val, func->common.function_name->val);
- } else {
- zend_error_noreturn(
- E_ERROR,
- "Non-static method %s::%s() cannot be called statically",
- func->common.scope->name->val, func->common.function_name->val);
- }
- }
- } else {
- zend_error(E_WARNING, "%s() expects parameter 1 to be a valid callback, %s", Z_STRVAL_P(opline->op1.zv), error);
- efree(error);
- func = (zend_function*)&zend_pass_function;
- called_scope = NULL;
- object = NULL;
- }
- EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
- func, opline->extended_value, called_scope, object, EX(call) TSRMLS_CC);
+ SAVE_OPLINE();
+ pow_function(EX_VAR(opline->result.var),
+ opline->op1.zv,
+ _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_CASE_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_MOD_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op2;
- zval *result = EX_VAR(opline->result.var);
SAVE_OPLINE();
- fast_equal_function(result,
- opline->op1.zv,
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ fast_mod_function(EX_VAR(opline->result.var),
+ opline->op1.zv,
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SL_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
- zval *expr_ptr, new_expr;
+ zend_free_op free_op2;
SAVE_OPLINE();
- if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) &&
- (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
- expr_ptr = NULL;
- if (IS_CONST == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
- }
- ZVAL_MAKE_REF(expr_ptr);
- Z_ADDREF_P(expr_ptr);
-
- } else {
- expr_ptr = opline->op1.zv;
- if (IS_CONST == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&new_expr, expr_ptr);
- expr_ptr = &new_expr;
- } else if (IS_CONST == IS_CONST) {
- if (!Z_IMMUTABLE_P(expr_ptr)) {
- ZVAL_DUP(&new_expr, expr_ptr);
- expr_ptr = &new_expr;
- }
- } else if ((IS_CONST == IS_CV || IS_CONST == IS_VAR) && Z_ISREF_P(expr_ptr)) {
- expr_ptr = Z_REFVAL_P(expr_ptr);
- if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
-
- } else if (IS_CONST == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
- Z_ADDREF_P(expr_ptr);
- }
- }
-
- if (IS_TMP_VAR != IS_UNUSED) {
- zend_free_op free_op2;
- zval *offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- zend_string *str;
- zend_ulong hval;
+ shift_left_function(EX_VAR(opline->result.var),
+ opline->op1.zv,
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
-add_again:
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- goto num_index;
- case IS_LONG:
- hval = Z_LVAL_P(offset);
-num_index:
- zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
- break;
- case IS_STRING:
- str = Z_STR_P(offset);
- if (IS_TMP_VAR != IS_CONST) {
- if (ZEND_HANDLE_NUMERIC(str, hval)) {
- goto num_index;
- }
- }
-str_index:
- zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
- break;
- case IS_NULL:
- str = STR_EMPTY_ALLOC();
- goto str_index;
- case IS_FALSE:
- hval = 0;
- goto num_index;
- case IS_TRUE:
- hval = 1;
- goto num_index;
- case IS_REFERENCE:
- offset = Z_REFVAL_P(offset);
- goto add_again;
- break;
- default:
- zend_error(E_WARNING, "Illegal offset type");
- zval_ptr_dtor(expr_ptr);
- /* do nothing */
- break;
- }
- zval_ptr_dtor_nogc(free_op2);
- } else {
- zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
- }
+ zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SR_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- zval *array;
- uint32_t size;
USE_OPLINE
+ zend_free_op free_op2;
- array = EX_VAR(opline->result.var);
- if (IS_CONST != IS_UNUSED) {
- size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
- } else {
- size = 0;
- }
- ZVAL_NEW_ARR(array);
- zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
-
- if (IS_CONST != IS_UNUSED) {
- /* Explicitly initialize array as not-packed if flag is set */
- if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
- zend_hash_real_init(Z_ARRVAL_P(array), 0);
- }
- }
+ SAVE_OPLINE();
+ shift_right_function(EX_VAR(opline->result.var),
+ opline->op1.zv,
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
- if (IS_CONST == IS_UNUSED) {
- ZEND_VM_NEXT_OPCODE();
-#if 0 || IS_CONST != IS_UNUSED
- } else {
- return ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-#endif
- }
+ zval_ptr_dtor_nogc(free_op2);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_CONCAT_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op2;
- zval *container;
- int result;
- zend_ulong hval;
- zval *offset;
SAVE_OPLINE();
- container = opline->op1.zv;
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-
- if (IS_CONST != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
- HashTable *ht = Z_ARRVAL_P(container);
- zval *value;
- zend_string *str;
-
-isset_again:
- if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
- str = Z_STR_P(offset);
- if (IS_TMP_VAR != IS_CONST) {
- if (ZEND_HANDLE_NUMERIC(str, hval)) {
- goto num_index_prop;
- }
- }
-str_index_prop:
- value = zend_hash_find_ind(ht, str);
- } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
- hval = Z_LVAL_P(offset);
-num_index_prop:
- value = zend_hash_index_find(ht, hval);
- } else {
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- goto num_index_prop;
- case IS_NULL:
- str = STR_EMPTY_ALLOC();
- goto str_index_prop;
- case IS_FALSE:
- hval = 0;
- goto num_index_prop;
- case IS_TRUE:
- hval = 1;
- goto num_index_prop;
- case IS_RESOURCE:
- hval = Z_RES_HANDLE_P(offset);
- goto num_index_prop;
- case IS_REFERENCE:
- offset = Z_REFVAL_P(offset);
- goto isset_again;
- default:
- zend_error(E_WARNING, "Illegal offset type in isset or empty");
- value = NULL;
- break;
- }
- }
-
- if (opline->extended_value & ZEND_ISSET) {
- /* > IS_NULL means not IS_UNDEF and not IS_NULL */
- result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
- }
- } else if (IS_CONST == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
- result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to check element of non-array");
- result = 0;
- }
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
- }
- } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
- zval tmp;
-
- result = 0;
- if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
- if (IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) {
- ZVAL_DEREF(offset);
- }
- if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
- || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
- && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
- ZVAL_DUP(&tmp, offset);
- convert_to_long(&tmp);
- offset = &tmp;
- }
- }
- if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
- if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
- if ((opline->extended_value & ZEND_ISSET) ||
- Z_STRVAL_P(container)[offset->value.lval] != '0') {
- result = 1;
- }
- }
- }
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
- }
- } else {
- result = ((opline->extended_value & ZEND_ISSET) == 0);
- }
-
- zval_ptr_dtor_nogc(free_op2);
- ZVAL_BOOL(EX_VAR(opline->result.var), result);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
- zval *container;
- int result;
- zval *offset;
-
- SAVE_OPLINE();
- container = opline->op1.zv;
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-
- if (IS_CONST == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
- result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to check property of non-object");
- result = 0;
- }
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
- }
- } else {
- result = ((opline->extended_value & ZEND_ISSET) == 0);
- }
-
- zval_ptr_dtor_nogc(free_op2);
- ZVAL_BOOL(EX_VAR(opline->result.var), result);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_YIELD_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- /* The generator object is stored in EX(return_value) */
- zend_generator *generator = (zend_generator *) EX(return_value);
-
- if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
- zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
- }
-
- /* Destroy the previously yielded value */
- zval_ptr_dtor(&generator->value);
-
- /* Destroy the previously yielded key */
- zval_ptr_dtor(&generator->key);
-
- /* Set the new yielded value */
- if (IS_CONST != IS_UNUSED) {
-
-
- if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
- /* Constants and temporary variables aren't yieldable by reference,
- * but we still allow them with a notice. */
- if (IS_CONST == IS_CONST || IS_CONST == IS_TMP_VAR) {
- zval *value;
-
- zend_error(E_NOTICE, "Only variable references should be yielded by reference");
-
- value = opline->op1.zv;
- ZVAL_COPY_VALUE(&generator->value, value);
- if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
-
- /* Temporary variables don't need ctor copying */
- if (IS_CONST != IS_TMP_VAR) {
- zval_opt_copy_ctor(&generator->value);
- }
- } else {
- zval *value_ptr = NULL;
-
- if (IS_CONST == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
- }
-
- /* If a function call result is yielded and the function did
- * not return by reference we throw a notice. */
- if (IS_CONST == IS_VAR &&
- (value_ptr == &EG(uninitialized_zval) ||
- (opline->extended_value == ZEND_RETURNS_FUNCTION &&
- !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
- zend_error(E_NOTICE, "Only variable references should be yielded by reference");
- } else {
- ZVAL_MAKE_REF(value_ptr);
- }
- ZVAL_COPY(&generator->value, value_ptr);
-
- }
- } else {
- zval *value = opline->op1.zv;
-
- /* Consts, temporary variables and references need copying */
- if (IS_CONST == IS_CONST) {
- ZVAL_DUP(&generator->value, value);
- } else if (IS_CONST == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&generator->value, value);
- } else if ((IS_CONST == IS_CV || IS_CONST == IS_VAR) && Z_ISREF_P(value)) {
- ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
-
- } else {
- ZVAL_COPY_VALUE(&generator->value, value);
- if (IS_CONST == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
- }
- }
- }
- } else {
- /* If no value was specified yield null */
- ZVAL_NULL(&generator->value);
- }
-
- /* Set the new yielded key */
- if (IS_TMP_VAR != IS_UNUSED) {
- zend_free_op free_op2;
- zval *key = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-
- /* Consts, temporary variables and references need copying */
- if (IS_TMP_VAR == IS_CONST) {
- ZVAL_DUP(&generator->key, key);
- } else if (IS_TMP_VAR == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&generator->key, key);
- } else if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && Z_ISREF_P(key)) {
- ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
-
- } else {
- ZVAL_COPY_VALUE(&generator->key, key);
- if (IS_TMP_VAR == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
- }
- }
-
- if (Z_TYPE(generator->key) == IS_LONG
- && Z_LVAL(generator->key) > generator->largest_used_integer_key
- ) {
- generator->largest_used_integer_key = Z_LVAL(generator->key);
- }
- } else {
- /* If no key was specified we use auto-increment keys */
- generator->largest_used_integer_key++;
- ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
- }
-
- if (RETURN_VALUE_USED(opline)) {
- /* If the return value of yield is used set the send
- * target and initialize it to NULL */
- generator->send_target = EX_VAR(opline->result.var);
- ZVAL_NULL(generator->send_target);
- } else {
- generator->send_target = NULL;
- }
-
- /* We increment to the next op, so we are at the correct position when the
- * generator is resumed. */
- ZEND_VM_INC_OPCODE();
-
- /* The GOTO VM uses a local opline variable. We need to set the opline
- * variable in execute_data so we don't resume at an old position. */
- SAVE_OPLINE();
-
- ZEND_VM_RETURN();
-}
-
-static int ZEND_FASTCALL ZEND_POW_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
-
- SAVE_OPLINE();
- pow_function(EX_VAR(opline->result.var),
- opline->op1.zv,
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
-
- zval_ptr_dtor_nogc(free_op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_MOD_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
-
- SAVE_OPLINE();
- fast_mod_function(EX_VAR(opline->result.var),
- opline->op1.zv,
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
-
- zval_ptr_dtor_nogc(free_op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_SL_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
-
- SAVE_OPLINE();
- shift_left_function(EX_VAR(opline->result.var),
- opline->op1.zv,
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
-
- zval_ptr_dtor_nogc(free_op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_SR_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
-
- SAVE_OPLINE();
- shift_right_function(EX_VAR(opline->result.var),
- opline->op1.zv,
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
-
- zval_ptr_dtor_nogc(free_op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_CONCAT_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
-
- SAVE_OPLINE();
- concat_function(EX_VAR(opline->result.var),
- opline->op1.zv,
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ concat_function(EX_VAR(opline->result.var),
+ opline->op1.zv,
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INIT_USER_CALL_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
- zval *container;
zend_free_op free_op2;
- zval *offset;
-
- SAVE_OPLINE();
- container = opline->op1.zv;
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
- if ((IS_CONST != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
- UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
- zend_error(E_NOTICE, "Trying to get property of non-object");
- ZVAL_NULL(EX_VAR(opline->result.var));
- } else {
- zval *retval;
-
- /* here we are sure we are dealing with an object */
- do {
- if (IS_VAR == IS_CONST &&
- EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
- zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
- zend_object *zobj = Z_OBJ_P(container);
-
- if (EXPECTED(prop_info)) {
- retval = OBJ_PROP(zobj, prop_info->offset);
- if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- } else if (EXPECTED(zobj->properties != NULL)) {
- retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
- if (EXPECTED(retval)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- }
- }
-
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+ zval *function_name = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+ zend_fcall_info_cache fcc;
+ char *error = NULL;
+ zend_function *func;
+ zend_class_entry *called_scope;
+ zend_object *object;
- if (retval != EX_VAR(opline->result.var)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ if (zend_is_callable_ex(function_name, NULL, 0, NULL, &fcc, &error TSRMLS_CC)) {
+ if (error) {
+ efree(error);
+ }
+ func = fcc.function_handler;
+ if (func->common.fn_flags & ZEND_ACC_CLOSURE) {
+ /* Delay closure destruction until its invocation */
+ func->common.prototype = (zend_function*)Z_OBJ_P(function_name);
+ Z_ADDREF_P(function_name);
+ }
+ called_scope = fcc.called_scope;
+ object = fcc.object;
+ if (object) {
+ GC_REFCOUNT(object)++; /* For $this pointer */
+ } else if (func->common.scope &&
+ !(func->common.fn_flags & ZEND_ACC_STATIC)) {
+ if (func->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
+ zend_error(E_STRICT,
+ "Non-static method %s::%s() should not be called statically",
+ func->common.scope->name->val, func->common.function_name->val);
+ } else {
+ zend_error_noreturn(
+ E_ERROR,
+ "Non-static method %s::%s() cannot be called statically",
+ func->common.scope->name->val, func->common.function_name->val);
}
- } while (0);
+ }
+ } else {
+ zend_error(E_WARNING, "%s() expects parameter 1 to be a valid callback, %s", Z_STRVAL_P(opline->op1.zv), error);
+ efree(error);
+ func = (zend_function*)&zend_pass_function;
+ called_scope = NULL;
+ object = NULL;
}
- zval_ptr_dtor_nogc(free_op2);
+ EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
+ func, opline->extended_value, called_scope, object, EX(call) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_UNSET_VAR_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval tmp, *varname;
+ HashTable *target_symbol_table;
- zval *container;
- zend_free_op free_op2;
- zval *offset;
SAVE_OPLINE();
- container = opline->op1.zv;
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
- if ((IS_CONST != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
- UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- } else {
- zval *retval;
+ if (IS_CONST == IS_CV &&
+ IS_VAR == IS_UNUSED &&
+ (opline->extended_value & ZEND_QUICK_SET)) {
+ zval *var = EX_VAR(opline->op1.var);
- /* here we are sure we are dealing with an object */
- do {
- if (IS_VAR == IS_CONST &&
- EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
- zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
- zend_object *zobj = Z_OBJ_P(container);
+ if (Z_REFCOUNTED_P(var)) {
+ zend_refcounted *garbage = Z_COUNTED_P(var);
- if (EXPECTED(prop_info)) {
- retval = OBJ_PROP(zobj, prop_info->offset);
- if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- } else if (EXPECTED(zobj->properties != NULL)) {
- retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
- if (EXPECTED(retval)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- }
+ if (!--GC_REFCOUNT(garbage)) {
+ ZVAL_UNDEF(var);
+ _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
+ } else {
+ GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
+ ZVAL_UNDEF(var);
}
+ } else {
+ ZVAL_UNDEF(var);
+ }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+ varname = opline->op1.zv;
- if (retval != EX_VAR(opline->result.var)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ ZVAL_UNDEF(&tmp);
+ if (IS_CONST != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
+ ZVAL_STR(&tmp, zval_get_string(varname));
+ varname = &tmp;
+ }
+
+ if (IS_VAR != IS_UNUSED) {
+ zend_class_entry *ce;
+
+ if (IS_VAR == IS_CONST) {
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ } else {
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ if (IS_CONST != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+ zend_string_release(Z_STR(tmp));
+ }
+
+ HANDLE_EXCEPTION();
+ }
+ if (UNEXPECTED(ce == NULL)) {
+ zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
+ }
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
}
- } while (0);
+ } else {
+ ce = Z_CE_P(EX_VAR(opline->op2.var));
+ }
+ zend_std_unset_static_property(ce, Z_STR_P(varname), ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+ } else {
+ target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+ zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
}
- zval_ptr_dtor_nogc(free_op2);
+ if (IS_CONST != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+ zend_string_release(Z_STR(tmp));
+ }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_VAR_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *container;
-
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- /* Behave like FETCH_OBJ_W */
- zend_free_op free_op1, free_op2;
- zval *property;
-
- SAVE_OPLINE();
- property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- container = NULL;
+ zval *value;
+ SAVE_OPLINE();
+ if (IS_CONST == IS_CV &&
+ IS_VAR == IS_UNUSED &&
+ (opline->extended_value & ZEND_QUICK_SET)) {
+ value = EX_VAR(opline->op1.var);
+ if (opline->extended_value & ZEND_ISSET) {
+ ZVAL_BOOL(EX_VAR(opline->result.var),
+ Z_TYPE_P(value) > IS_NULL &&
+ (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+ } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+ ZVAL_BOOL(EX_VAR(opline->result.var),
+ !i_zend_is_true(value TSRMLS_CC));
+ CHECK_EXCEPTION();
+ }
+ ZEND_VM_NEXT_OPCODE();
+ } else {
+
+ zval tmp, *varname = opline->op1.zv;
+
+ ZVAL_UNDEF(&tmp);
+ if (IS_CONST != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
+ ZVAL_STR(&tmp, zval_get_string(varname));
+ varname = &tmp;
+ }
+
+ if (IS_VAR != IS_UNUSED) {
+ zend_class_entry *ce;
+
+ if (IS_VAR == IS_CONST) {
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ } else {
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+ if (UNEXPECTED(ce == NULL)) {
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+ }
+ } else {
+ ce = Z_CE_P(EX_VAR(opline->op2.var));
+ }
+ value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+ } else {
+ HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+ value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
+ }
+
+ if (IS_CONST != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+ zend_string_release(Z_STR(tmp));
+ }
+
+ if (opline->extended_value & ZEND_ISSET) {
+ ZVAL_BOOL(EX_VAR(opline->result.var),
+ value && Z_TYPE_P(value) > IS_NULL &&
+ (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+ } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+ ZVAL_BOOL(EX_VAR(opline->result.var),
+ !value || !i_zend_is_true(value TSRMLS_CC));
+ }
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+}
+
+static int ZEND_FASTCALL ZEND_YIELD_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ /* The generator object is stored in EX(return_value) */
+ zend_generator *generator = (zend_generator *) EX(return_value);
+
+ if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
+ zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
+ }
+
+ /* Destroy the previously yielded value */
+ zval_ptr_dtor(&generator->value);
+
+ /* Destroy the previously yielded key */
+ zval_ptr_dtor(&generator->key);
+
+ /* Set the new yielded value */
+ if (IS_CONST != IS_UNUSED) {
+
+
+ if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
+ /* Constants and temporary variables aren't yieldable by reference,
+ * but we still allow them with a notice. */
+ if (IS_CONST == IS_CONST || IS_CONST == IS_TMP_VAR) {
+ zval *value;
+
+ zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+
+ value = opline->op1.zv;
+ ZVAL_COPY_VALUE(&generator->value, value);
+ if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
+
+ /* Temporary variables don't need ctor copying */
+ if (IS_CONST != IS_TMP_VAR) {
+ zval_opt_copy_ctor(&generator->value);
+ }
+ } else {
+ zval *value_ptr = NULL;
+
+ if (IS_CONST == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
+ }
+
+ /* If a function call result is yielded and the function did
+ * not return by reference we throw a notice. */
+ if (IS_CONST == IS_VAR &&
+ (value_ptr == &EG(uninitialized_zval) ||
+ (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+ !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+ zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+ } else {
+ ZVAL_MAKE_REF(value_ptr);
+ }
+ ZVAL_COPY(&generator->value, value_ptr);
+
+ }
+ } else {
+ zval *value = opline->op1.zv;
+
+ /* Consts, temporary variables and references need copying */
+ if (IS_CONST == IS_CONST) {
+ ZVAL_DUP(&generator->value, value);
+ } else if (IS_CONST == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&generator->value, value);
+ } else if ((IS_CONST == IS_CV || IS_CONST == IS_VAR) && Z_ISREF_P(value)) {
+ ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
+
+ } else {
+ ZVAL_COPY_VALUE(&generator->value, value);
+ if (IS_CONST == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+ }
+ }
+ }
+ } else {
+ /* If no value was specified yield null */
+ ZVAL_NULL(&generator->value);
+ }
+
+ /* Set the new yielded key */
+ if (IS_VAR != IS_UNUSED) {
+ zend_free_op free_op2;
+ zval *key = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+
+ /* Consts, temporary variables and references need copying */
+ if (IS_VAR == IS_CONST) {
+ ZVAL_DUP(&generator->key, key);
+ } else if (IS_VAR == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&generator->key, key);
+ } else if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && Z_ISREF_P(key)) {
+ ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
+ zval_ptr_dtor_nogc(free_op2);
+ } else {
+ ZVAL_COPY_VALUE(&generator->key, key);
+ if (IS_VAR == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
+ }
+ }
+
+ if (Z_TYPE(generator->key) == IS_LONG
+ && Z_LVAL(generator->key) > generator->largest_used_integer_key
+ ) {
+ generator->largest_used_integer_key = Z_LVAL(generator->key);
+ }
+ } else {
+ /* If no key was specified we use auto-increment keys */
+ generator->largest_used_integer_key++;
+ ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
+ }
+
+ if (RETURN_VALUE_USED(opline)) {
+ /* If the return value of yield is used set the send
+ * target and initialize it to NULL */
+ generator->send_target = EX_VAR(opline->result.var);
+ ZVAL_NULL(generator->send_target);
+ } else {
+ generator->send_target = NULL;
+ }
+
+ /* We increment to the next op, so we are at the correct position when the
+ * generator is resumed. */
+ ZEND_VM_INC_OPCODE();
+
+ /* The GOTO VM uses a local opline variable. We need to set the opline
+ * variable in execute_data so we don't resume at an old position. */
+ SAVE_OPLINE();
+
+ ZEND_VM_RETURN();
+}
+
+static int ZEND_FASTCALL ZEND_POW_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op2;
+
+ SAVE_OPLINE();
+ pow_function(EX_VAR(opline->result.var),
+ opline->op1.zv,
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+
+ zval_ptr_dtor_nogc(free_op2);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CONST_UNUSED(int type, ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ zval *varname;
+ zval *retval;
+ zend_string *name;
+ HashTable *target_symbol_table;
+
+ SAVE_OPLINE();
+ varname = opline->op1.zv;
+
+ if (IS_CONST == IS_CONST) {
+ name = Z_STR_P(varname);
+ } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
+ name = Z_STR_P(varname);
+ zend_string_addref(name);
+ } else {
+ name = zval_get_string(varname);
+ }
+
+ if (IS_UNUSED != IS_UNUSED) {
+ zend_class_entry *ce;
+
+ if (IS_UNUSED == IS_CONST) {
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ } else {
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+ if (UNEXPECTED(ce == NULL)) {
+ if (IS_CONST != IS_CONST) {
+ zend_string_release(name);
+ }
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+ }
+ } else {
+ ce = Z_CE_P(EX_VAR(opline->op2.var));
+ }
+ retval = zend_std_get_static_property(ce, name, 0, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+
+ } else {
+ target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+ retval = zend_hash_find(target_symbol_table, name);
+ if (retval == NULL) {
+ switch (type) {
+ case BP_VAR_R:
+ case BP_VAR_UNSET:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_IS:
+ retval = &EG(uninitialized_zval);
+ break;
+ case BP_VAR_RW:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_W:
+ retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
+ break;
+ EMPTY_SWITCH_DEFAULT_CASE()
+ }
+ /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
+ } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
+ retval = Z_INDIRECT_P(retval);
+ if (Z_TYPE_P(retval) == IS_UNDEF) {
+ switch (type) {
+ case BP_VAR_R:
+ case BP_VAR_UNSET:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_IS:
+ retval = &EG(uninitialized_zval);
+ break;
+ case BP_VAR_RW:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_W:
+ ZVAL_NULL(retval);
+ break;
+ EMPTY_SWITCH_DEFAULT_CASE()
+ }
+ }
+ }
+ if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
+ if (Z_CONSTANT_P(retval)) {
+ zval_update_constant(retval, 1 TSRMLS_CC);
+ }
+ } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
+
+ }
+ }
+
+ if (IS_CONST != IS_CONST) {
+ zend_string_release(name);
+ }
+
+ ZEND_ASSERT(retval != NULL);
+ if (type == BP_VAR_R || type == BP_VAR_IS) {
+ if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
+ ZVAL_UNREF(retval);
+ }
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ } else {
+ ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
+ }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_FETCH_R_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL ZEND_FETCH_W_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL ZEND_FETCH_RW_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL ZEND_FETCH_FUNC_ARG_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+ return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else {
+ return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
+
+static int ZEND_FASTCALL ZEND_FETCH_UNSET_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL ZEND_FETCH_IS_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zval *container;
+ zend_free_op free_op1;
+
+ SAVE_OPLINE();
+
+ if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
if (IS_CONST == IS_CONST || IS_CONST == IS_TMP_VAR) {
zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
}
+ container = NULL;
if (IS_CONST == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CONST, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
if (IS_CONST == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+
} else {
- return ZEND_FETCH_OBJ_R_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ if (IS_UNUSED == IS_UNUSED) {
+ zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
+ }
+ container = opline->op1.zv;
+ zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
+
+
}
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *function_name;
}
if (IS_CONST == IS_CONST &&
- IS_VAR == IS_CONST &&
+ IS_UNUSED == IS_CONST &&
CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
fbc = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
} else if (IS_CONST != IS_CONST &&
- IS_VAR == IS_CONST &&
+ IS_UNUSED == IS_CONST &&
(fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce))) {
/* do nothing */
- } else if (IS_VAR != IS_UNUSED) {
- zend_free_op free_op2;
+ } else if (IS_UNUSED != IS_UNUSED) {
- function_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_VAR != IS_CONST) {
+
+ function_name = NULL;
+ if (IS_UNUSED != IS_CONST) {
if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
if (UNEXPECTED(EG(exception) != NULL)) {
HANDLE_EXCEPTION();
if (ce->get_static_method) {
fbc = ce->get_static_method(ce, Z_STR_P(function_name) TSRMLS_CC);
} else {
- fbc = zend_std_get_static_method(ce, Z_STR_P(function_name), ((IS_VAR == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
+ fbc = zend_std_get_static_method(ce, Z_STR_P(function_name), ((IS_UNUSED == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
}
if (UNEXPECTED(fbc == NULL)) {
zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name->val, Z_STRVAL_P(function_name));
}
- if (IS_VAR == IS_CONST &&
+ if (IS_UNUSED == IS_CONST &&
EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0)) {
if (IS_CONST == IS_CONST) {
CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), ce, fbc);
}
}
- if (IS_VAR != IS_CONST) {
- zval_ptr_dtor_nogc(free_op2);
+ if (IS_UNUSED != IS_CONST) {
+
}
} else {
if (UNEXPECTED(ce->constructor == NULL)) {
EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
fbc, opline->extended_value, ce, object, EX(call) TSRMLS_CC);
- if (IS_VAR == IS_UNUSED) {
+ if (IS_UNUSED == IS_UNUSED) {
EX(call)->return_value = NULL;
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_USER_CALL_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
- zval *function_name = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
- zend_fcall_info_cache fcc;
- char *error = NULL;
- zend_function *func;
- zend_class_entry *called_scope;
- zend_object *object;
-
- if (zend_is_callable_ex(function_name, NULL, 0, NULL, &fcc, &error TSRMLS_CC)) {
- if (error) {
- efree(error);
- }
- func = fcc.function_handler;
- if (func->common.fn_flags & ZEND_ACC_CLOSURE) {
- /* Delay closure destruction until its invocation */
- func->common.prototype = (zend_function*)Z_OBJ_P(function_name);
- Z_ADDREF_P(function_name);
- }
- called_scope = fcc.called_scope;
- object = fcc.object;
- if (object) {
- GC_REFCOUNT(object)++; /* For $this pointer */
- } else if (func->common.scope &&
- !(func->common.fn_flags & ZEND_ACC_STATIC)) {
- if (func->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
- zend_error(E_STRICT,
- "Non-static method %s::%s() should not be called statically",
- func->common.scope->name->val, func->common.function_name->val);
- } else {
- zend_error_noreturn(
- E_ERROR,
- "Non-static method %s::%s() cannot be called statically",
- func->common.scope->name->val, func->common.function_name->val);
- }
- }
- } else {
- zend_error(E_WARNING, "%s() expects parameter 1 to be a valid callback, %s", Z_STRVAL_P(opline->op1.zv), error);
- efree(error);
- func = (zend_function*)&zend_pass_function;
- called_scope = NULL;
- object = NULL;
- }
-
- EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
- func, opline->extended_value, called_scope, object, EX(call) TSRMLS_CC);
-
- zval_ptr_dtor_nogc(free_op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_CASE_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
- zval *result = EX_VAR(opline->result.var);
-
- SAVE_OPLINE();
- fast_equal_function(result,
- opline->op1.zv,
- _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
-
- zval_ptr_dtor_nogc(free_op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
}
}
- if (IS_VAR != IS_UNUSED) {
- zend_free_op free_op2;
- zval *offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ if (IS_UNUSED != IS_UNUSED) {
+
+ zval *offset = NULL;
zend_string *str;
zend_ulong hval;
break;
case IS_STRING:
str = Z_STR_P(offset);
- if (IS_VAR != IS_CONST) {
+ if (IS_UNUSED != IS_CONST) {
if (ZEND_HANDLE_NUMERIC(str, hval)) {
goto num_index;
}
/* do nothing */
break;
}
- zval_ptr_dtor_nogc(free_op2);
+
} else {
zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
zval *array;
uint32_t size;
ZEND_VM_NEXT_OPCODE();
#if 0 || IS_CONST != IS_UNUSED
} else {
- return ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
#endif
}
}
-static int ZEND_FASTCALL ZEND_UNSET_VAR_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_UNSET_VAR_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval tmp, *varname;
SAVE_OPLINE();
if (IS_CONST == IS_CV &&
- IS_VAR == IS_UNUSED &&
+ IS_UNUSED == IS_UNUSED &&
(opline->extended_value & ZEND_QUICK_SET)) {
zval *var = EX_VAR(opline->op1.var);
varname = &tmp;
}
- if (IS_VAR != IS_UNUSED) {
+ if (IS_UNUSED != IS_UNUSED) {
zend_class_entry *ce;
- if (IS_VAR == IS_CONST) {
+ if (IS_UNUSED == IS_CONST) {
if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
} else {
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_VAR_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_VAR_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *value;
SAVE_OPLINE();
if (IS_CONST == IS_CV &&
- IS_VAR == IS_UNUSED &&
+ IS_UNUSED == IS_UNUSED &&
(opline->extended_value & ZEND_QUICK_SET)) {
value = EX_VAR(opline->op1.var);
if (opline->extended_value & ZEND_ISSET) {
varname = &tmp;
}
- if (IS_VAR != IS_UNUSED) {
+ if (IS_UNUSED != IS_UNUSED) {
zend_class_entry *ce;
- if (IS_VAR == IS_CONST) {
+ if (IS_UNUSED == IS_CONST) {
if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
} else {
}
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_DECLARE_LAMBDA_FUNCTION_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
- zval *container;
- int result;
- zend_ulong hval;
- zval *offset;
+ zval *zfunc;
+ int closure_is_static, closure_is_being_defined_inside_static_context;
SAVE_OPLINE();
- container = opline->op1.zv;
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_CONST != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
- HashTable *ht = Z_ARRVAL_P(container);
- zval *value;
- zend_string *str;
-
-isset_again:
- if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
- str = Z_STR_P(offset);
- if (IS_VAR != IS_CONST) {
- if (ZEND_HANDLE_NUMERIC(str, hval)) {
- goto num_index_prop;
- }
- }
-str_index_prop:
- value = zend_hash_find_ind(ht, str);
- } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
- hval = Z_LVAL_P(offset);
-num_index_prop:
- value = zend_hash_index_find(ht, hval);
- } else {
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- goto num_index_prop;
- case IS_NULL:
- str = STR_EMPTY_ALLOC();
- goto str_index_prop;
- case IS_FALSE:
- hval = 0;
- goto num_index_prop;
- case IS_TRUE:
- hval = 1;
- goto num_index_prop;
- case IS_RESOURCE:
- hval = Z_RES_HANDLE_P(offset);
- goto num_index_prop;
- case IS_REFERENCE:
- offset = Z_REFVAL_P(offset);
- goto isset_again;
- default:
- zend_error(E_WARNING, "Illegal offset type in isset or empty");
- value = NULL;
- break;
- }
- }
-
- if (opline->extended_value & ZEND_ISSET) {
- /* > IS_NULL means not IS_UNDEF and not IS_NULL */
- result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
- }
- } else if (IS_CONST == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
- result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to check element of non-array");
- result = 0;
- }
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
- }
- } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
- zval tmp;
-
- result = 0;
- if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
- if (IS_VAR == IS_CV || IS_VAR == IS_VAR) {
- ZVAL_DEREF(offset);
- }
- if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
- || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
- && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
- ZVAL_DUP(&tmp, offset);
- convert_to_long(&tmp);
- offset = &tmp;
- }
- }
- if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
- if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
- if ((opline->extended_value & ZEND_ISSET) ||
- Z_STRVAL_P(container)[offset->value.lval] != '0') {
- result = 1;
- }
- }
- }
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
- }
- } else {
- result = ((opline->extended_value & ZEND_ISSET) == 0);
+ if (UNEXPECTED((zfunc = zend_hash_find(EG(function_table), Z_STR_P(opline->op1.zv))) == NULL) ||
+ UNEXPECTED(Z_FUNC_P(zfunc)->type != ZEND_USER_FUNCTION)) {
+ zend_error_noreturn(E_ERROR, "Base lambda function for closure not found");
}
- zval_ptr_dtor_nogc(free_op2);
- ZVAL_BOOL(EX_VAR(opline->result.var), result);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
- zval *container;
- int result;
- zval *offset;
-
- SAVE_OPLINE();
- container = opline->op1.zv;
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
- if (IS_CONST == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
- result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to check property of non-object");
- result = 0;
- }
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
- }
+ closure_is_static = Z_FUNC_P(zfunc)->common.fn_flags & ZEND_ACC_STATIC;
+ closure_is_being_defined_inside_static_context = EX(func)->common.fn_flags & ZEND_ACC_STATIC;
+ if (closure_is_static || closure_is_being_defined_inside_static_context) {
+ zend_create_closure(EX_VAR(opline->result.var), Z_FUNC_P(zfunc), EX(called_scope), NULL TSRMLS_CC);
} else {
- result = ((opline->extended_value & ZEND_ISSET) == 0);
+ zend_create_closure(EX_VAR(opline->result.var), Z_FUNC_P(zfunc), EG(scope), Z_OBJ(EX(This)) ? &EX(This) : NULL TSRMLS_CC);
}
- zval_ptr_dtor_nogc(free_op2);
- ZVAL_BOOL(EX_VAR(opline->result.var), result);
-
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_YIELD_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_YIELD_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
}
/* Set the new yielded key */
- if (IS_VAR != IS_UNUSED) {
- zend_free_op free_op2;
- zval *key = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ if (IS_UNUSED != IS_UNUSED) {
+
+ zval *key = NULL;
/* Consts, temporary variables and references need copying */
- if (IS_VAR == IS_CONST) {
+ if (IS_UNUSED == IS_CONST) {
ZVAL_DUP(&generator->key, key);
- } else if (IS_VAR == IS_TMP_VAR) {
+ } else if (IS_UNUSED == IS_TMP_VAR) {
ZVAL_COPY_VALUE(&generator->key, key);
- } else if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && Z_ISREF_P(key)) {
+ } else if ((IS_UNUSED == IS_VAR || IS_UNUSED == IS_CV) && Z_ISREF_P(key)) {
ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
- zval_ptr_dtor_nogc(free_op2);
+
} else {
ZVAL_COPY_VALUE(&generator->key, key);
- if (IS_VAR == IS_CV) {
+ if (IS_UNUSED == IS_CV) {
if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
}
}
ZEND_VM_RETURN();
}
-static int ZEND_FASTCALL ZEND_POW_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ADD_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
+
SAVE_OPLINE();
- pow_function(EX_VAR(opline->result.var),
+ fast_add_function(EX_VAR(opline->result.var),
opline->op1.zv,
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
- zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CONST_UNUSED(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SUB_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *varname;
- zval *retval;
- zend_string *name;
- HashTable *target_symbol_table;
SAVE_OPLINE();
- varname = opline->op1.zv;
-
- if (IS_CONST == IS_CONST) {
- name = Z_STR_P(varname);
- } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
- name = Z_STR_P(varname);
- zend_string_addref(name);
- } else {
- name = zval_get_string(varname);
- }
+ fast_sub_function(EX_VAR(opline->result.var),
+ opline->op1.zv,
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
- if (IS_UNUSED != IS_UNUSED) {
- zend_class_entry *ce;
- if (IS_UNUSED == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- if (IS_CONST != IS_CONST) {
- zend_string_release(name);
- }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
- }
- retval = zend_std_get_static_property(ce, name, 0, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+static int ZEND_FASTCALL ZEND_MUL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- } else {
- target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- retval = zend_hash_find(target_symbol_table, name);
- if (retval == NULL) {
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_UNSET:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_IS:
- retval = &EG(uninitialized_zval);
- break;
- case BP_VAR_RW:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_W:
- retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
- }
- /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
- } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
- retval = Z_INDIRECT_P(retval);
- if (Z_TYPE_P(retval) == IS_UNDEF) {
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_UNSET:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_IS:
- retval = &EG(uninitialized_zval);
- break;
- case BP_VAR_RW:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_W:
- ZVAL_NULL(retval);
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
- }
- }
- }
- if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
- if (Z_CONSTANT_P(retval)) {
- zval_update_constant(retval, 1 TSRMLS_CC);
- }
- } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
- }
- }
+ SAVE_OPLINE();
+ fast_mul_function(EX_VAR(opline->result.var),
+ opline->op1.zv,
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
- if (IS_CONST != IS_CONST) {
- zend_string_release(name);
- }
- ZEND_ASSERT(retval != NULL);
- if (type == BP_VAR_R || type == BP_VAR_IS) {
- if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
- ZVAL_UNREF(retval);
- }
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- } else {
- ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
- }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_R_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_DIV_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ USE_OPLINE
-static int ZEND_FASTCALL ZEND_FETCH_W_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-static int ZEND_FASTCALL ZEND_FETCH_RW_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ SAVE_OPLINE();
+ fast_div_function(EX_VAR(opline->result.var),
+ opline->op1.zv,
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_FUNC_ARG_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_MOD_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else {
- return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
+
+ SAVE_OPLINE();
+ fast_mod_function(EX_VAR(opline->result.var),
+ opline->op1.zv,
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_UNSET_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ USE_OPLINE
+
+
+ SAVE_OPLINE();
+ shift_left_function(EX_VAR(opline->result.var),
+ opline->op1.zv,
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_IS_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SR_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ USE_OPLINE
+
+
+ SAVE_OPLINE();
+ shift_right_function(EX_VAR(opline->result.var),
+ opline->op1.zv,
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_CONCAT_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *container;
- zend_free_op free_op1;
+
SAVE_OPLINE();
+ concat_function(EX_VAR(opline->result.var),
+ opline->op1.zv,
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- if (IS_CONST == IS_CONST || IS_CONST == IS_TMP_VAR) {
- zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
- }
- container = NULL;
- if (IS_CONST == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
- if (IS_CONST == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_IS_IDENTICAL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- } else {
- if (IS_UNUSED == IS_UNUSED) {
- zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
- }
- container = opline->op1.zv;
- zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
+
+ SAVE_OPLINE();
+ fast_is_identical_function(EX_VAR(opline->result.var),
+ opline->op1.zv,
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
- }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_IS_NOT_IDENTICAL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *function_name;
- zend_class_entry *ce;
- zend_object *object;
- zend_function *fbc;
+
+ zval *result = EX_VAR(opline->result.var);
SAVE_OPLINE();
+ fast_is_not_identical_function(result,
+ opline->op1.zv,
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
- if (IS_CONST == IS_CONST) {
- /* no function found. try a static method in class */
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op1.zv), opline->op1.zv + 1, ZEND_FETCH_CLASS_DEFAULT TSRMLS_CC);
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- if (UNEXPECTED(ce == NULL)) {
- zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op1.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op1.var));
- }
- if (IS_CONST == IS_CONST &&
- IS_UNUSED == IS_CONST &&
- CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- fbc = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else if (IS_CONST != IS_CONST &&
- IS_UNUSED == IS_CONST &&
- (fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce))) {
- /* do nothing */
- } else if (IS_UNUSED != IS_UNUSED) {
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+static int ZEND_FASTCALL ZEND_IS_EQUAL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- function_name = NULL;
- if (IS_UNUSED != IS_CONST) {
- if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- zend_error_noreturn(E_ERROR, "Function name must be a string");
- }
- }
+ zval *result = EX_VAR(opline->result.var);
- if (ce->get_static_method) {
- fbc = ce->get_static_method(ce, Z_STR_P(function_name) TSRMLS_CC);
- } else {
- fbc = zend_std_get_static_method(ce, Z_STR_P(function_name), ((IS_UNUSED == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
- }
- if (UNEXPECTED(fbc == NULL)) {
- zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name->val, Z_STRVAL_P(function_name));
- }
- if (IS_UNUSED == IS_CONST &&
- EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
- EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0)) {
- if (IS_CONST == IS_CONST) {
- CACHE_PTR(Z_CACHE_SLOT_P(function_name), fbc);
- } else {
- CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), ce, fbc);
- }
- }
- if (IS_UNUSED != IS_CONST) {
+ SAVE_OPLINE();
+ fast_equal_function(result,
+ opline->op1.zv,
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
- }
- } else {
- if (UNEXPECTED(ce->constructor == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot call constructor");
- }
- if (Z_OBJ(EX(This)) && Z_OBJ(EX(This))->ce != ce->constructor->common.scope && (ce->constructor->common.fn_flags & ZEND_ACC_PRIVATE)) {
- zend_error_noreturn(E_ERROR, "Cannot call private %s::__construct()", ce->name->val);
- }
- fbc = ce->constructor;
- }
- object = NULL;
- if (!(fbc->common.fn_flags & ZEND_ACC_STATIC)) {
- if (Z_OBJ(EX(This))) {
- object = Z_OBJ(EX(This));
- GC_REFCOUNT(object)++;
- }
- if (!object ||
- !instanceof_function(object->ce, ce TSRMLS_CC)) {
- /* We are calling method of the other (incompatible) class,
- but passing $this. This is done for compatibility with php-4. */
- if (fbc->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
- zend_error(
- object ? E_DEPRECATED : E_STRICT,
- "Non-static method %s::%s() should not be called statically%s",
- fbc->common.scope->name->val, fbc->common.function_name->val,
- object ? ", assuming $this from incompatible context" : "");
- } else {
- /* An internal function assumes $this is present and won't check that. So PHP would crash by allowing the call. */
- zend_error_noreturn(
- E_ERROR,
- "Non-static method %s::%s() cannot be called statically%s",
- fbc->common.scope->name->val, fbc->common.function_name->val,
- object ? ", assuming $this from incompatible context" : "");
- }
- }
- }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- if (IS_CONST != IS_CONST) {
- /* previous opcode is ZEND_FETCH_CLASS */
- if ((opline-1)->extended_value == ZEND_FETCH_CLASS_PARENT || (opline-1)->extended_value == ZEND_FETCH_CLASS_SELF) {
- ce = EX(called_scope);
- }
- }
+static int ZEND_FASTCALL ZEND_IS_NOT_EQUAL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
- fbc, opline->extended_value, ce, object, EX(call) TSRMLS_CC);
+ zval *result = EX_VAR(opline->result.var);
+
+ SAVE_OPLINE();
+ fast_not_equal_function(result,
+ opline->op1.zv,
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
- if (IS_UNUSED == IS_UNUSED) {
- EX(call)->return_value = NULL;
- }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_IS_SMALLER_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *expr_ptr, new_expr;
+ zval *result = EX_VAR(opline->result.var);
SAVE_OPLINE();
- if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) &&
- (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
- expr_ptr = NULL;
- if (IS_CONST == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
- }
- ZVAL_MAKE_REF(expr_ptr);
- Z_ADDREF_P(expr_ptr);
-
- } else {
- expr_ptr = opline->op1.zv;
- if (IS_CONST == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&new_expr, expr_ptr);
- expr_ptr = &new_expr;
- } else if (IS_CONST == IS_CONST) {
- if (!Z_IMMUTABLE_P(expr_ptr)) {
- ZVAL_DUP(&new_expr, expr_ptr);
- expr_ptr = &new_expr;
- }
- } else if ((IS_CONST == IS_CV || IS_CONST == IS_VAR) && Z_ISREF_P(expr_ptr)) {
- expr_ptr = Z_REFVAL_P(expr_ptr);
- if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
-
- } else if (IS_CONST == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
- Z_ADDREF_P(expr_ptr);
- }
- }
-
- if (IS_UNUSED != IS_UNUSED) {
-
- zval *offset = NULL;
- zend_string *str;
- zend_ulong hval;
+ fast_is_smaller_function(result,
+ opline->op1.zv,
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-add_again:
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- goto num_index;
- case IS_LONG:
- hval = Z_LVAL_P(offset);
-num_index:
- zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
- break;
- case IS_STRING:
- str = Z_STR_P(offset);
- if (IS_UNUSED != IS_CONST) {
- if (ZEND_HANDLE_NUMERIC(str, hval)) {
- goto num_index;
- }
- }
-str_index:
- zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
- break;
- case IS_NULL:
- str = STR_EMPTY_ALLOC();
- goto str_index;
- case IS_FALSE:
- hval = 0;
- goto num_index;
- case IS_TRUE:
- hval = 1;
- goto num_index;
- case IS_REFERENCE:
- offset = Z_REFVAL_P(offset);
- goto add_again;
- break;
- default:
- zend_error(E_WARNING, "Illegal offset type");
- zval_ptr_dtor(expr_ptr);
- /* do nothing */
- break;
- }
- } else {
- zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
- }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- zval *array;
- uint32_t size;
- USE_OPLINE
-
- array = EX_VAR(opline->result.var);
- if (IS_CONST != IS_UNUSED) {
- size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
- } else {
- size = 0;
- }
- ZVAL_NEW_ARR(array);
- zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
-
- if (IS_CONST != IS_UNUSED) {
- /* Explicitly initialize array as not-packed if flag is set */
- if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
- zend_hash_real_init(Z_ARRVAL_P(array), 0);
- }
- }
-
- if (IS_CONST == IS_UNUSED) {
- ZEND_VM_NEXT_OPCODE();
-#if 0 || IS_CONST != IS_UNUSED
- } else {
- return ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-#endif
- }
-}
-
-static int ZEND_FASTCALL ZEND_UNSET_VAR_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_IS_SMALLER_OR_EQUAL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval tmp, *varname;
- HashTable *target_symbol_table;
+ zval *result = EX_VAR(opline->result.var);
SAVE_OPLINE();
- if (IS_CONST == IS_CV &&
- IS_UNUSED == IS_UNUSED &&
- (opline->extended_value & ZEND_QUICK_SET)) {
- zval *var = EX_VAR(opline->op1.var);
-
- if (Z_REFCOUNTED_P(var)) {
- zend_refcounted *garbage = Z_COUNTED_P(var);
-
- if (!--GC_REFCOUNT(garbage)) {
- ZVAL_UNDEF(var);
- _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
- } else {
- GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
- ZVAL_UNDEF(var);
- }
- } else {
- ZVAL_UNDEF(var);
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-
- varname = opline->op1.zv;
-
- ZVAL_UNDEF(&tmp);
- if (IS_CONST != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
- ZVAL_STR(&tmp, zval_get_string(varname));
- varname = &tmp;
- }
-
- if (IS_UNUSED != IS_UNUSED) {
- zend_class_entry *ce;
-
- if (IS_UNUSED == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(EG(exception) != NULL)) {
- if (IS_CONST != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
- }
-
- HANDLE_EXCEPTION();
- }
- if (UNEXPECTED(ce == NULL)) {
- zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
- }
- zend_std_unset_static_property(ce, Z_STR_P(varname), ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
- } else {
- target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
- }
+ fast_is_smaller_or_equal_function(result,
+ opline->op1.zv,
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
- if (IS_CONST != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
- }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_VAR_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BW_OR_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *value;
-
- SAVE_OPLINE();
- if (IS_CONST == IS_CV &&
- IS_UNUSED == IS_UNUSED &&
- (opline->extended_value & ZEND_QUICK_SET)) {
- value = EX_VAR(opline->op1.var);
- if (opline->extended_value & ZEND_ISSET) {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- !i_zend_is_true(value TSRMLS_CC));
- CHECK_EXCEPTION();
- }
- ZEND_VM_NEXT_OPCODE();
- } else {
-
- zval tmp, *varname = opline->op1.zv;
-
- ZVAL_UNDEF(&tmp);
- if (IS_CONST != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
- ZVAL_STR(&tmp, zval_get_string(varname));
- varname = &tmp;
- }
-
- if (IS_UNUSED != IS_UNUSED) {
- zend_class_entry *ce;
-
- if (IS_UNUSED == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
- }
- value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
- } else {
- HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
- }
- if (IS_CONST != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
- }
-
- if (opline->extended_value & ZEND_ISSET) {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- value && Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- !value || !i_zend_is_true(value TSRMLS_CC));
- }
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-}
-
-static int ZEND_FASTCALL ZEND_DECLARE_LAMBDA_FUNCTION_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *zfunc;
- int closure_is_static, closure_is_being_defined_inside_static_context;
SAVE_OPLINE();
+ bitwise_or_function(EX_VAR(opline->result.var),
+ opline->op1.zv,
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
- if (UNEXPECTED((zfunc = zend_hash_find(EG(function_table), Z_STR_P(opline->op1.zv))) == NULL) ||
- UNEXPECTED(Z_FUNC_P(zfunc)->type != ZEND_USER_FUNCTION)) {
- zend_error_noreturn(E_ERROR, "Base lambda function for closure not found");
- }
-
- closure_is_static = Z_FUNC_P(zfunc)->common.fn_flags & ZEND_ACC_STATIC;
- closure_is_being_defined_inside_static_context = EX(func)->common.fn_flags & ZEND_ACC_STATIC;
- if (closure_is_static || closure_is_being_defined_inside_static_context) {
- zend_create_closure(EX_VAR(opline->result.var), Z_FUNC_P(zfunc), EX(called_scope), NULL TSRMLS_CC);
- } else {
- zend_create_closure(EX_VAR(opline->result.var), Z_FUNC_P(zfunc), EG(scope), Z_OBJ(EX(This)) ? &EX(This) : NULL TSRMLS_CC);
- }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_YIELD_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- /* The generator object is stored in EX(return_value) */
- zend_generator *generator = (zend_generator *) EX(return_value);
-
- if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
- zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
- }
-
- /* Destroy the previously yielded value */
- zval_ptr_dtor(&generator->value);
-
- /* Destroy the previously yielded key */
- zval_ptr_dtor(&generator->key);
-
- /* Set the new yielded value */
- if (IS_CONST != IS_UNUSED) {
-
-
- if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
- /* Constants and temporary variables aren't yieldable by reference,
- * but we still allow them with a notice. */
- if (IS_CONST == IS_CONST || IS_CONST == IS_TMP_VAR) {
- zval *value;
-
- zend_error(E_NOTICE, "Only variable references should be yielded by reference");
-
- value = opline->op1.zv;
- ZVAL_COPY_VALUE(&generator->value, value);
- if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
-
- /* Temporary variables don't need ctor copying */
- if (IS_CONST != IS_TMP_VAR) {
- zval_opt_copy_ctor(&generator->value);
- }
- } else {
- zval *value_ptr = NULL;
-
- if (IS_CONST == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
- }
-
- /* If a function call result is yielded and the function did
- * not return by reference we throw a notice. */
- if (IS_CONST == IS_VAR &&
- (value_ptr == &EG(uninitialized_zval) ||
- (opline->extended_value == ZEND_RETURNS_FUNCTION &&
- !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
- zend_error(E_NOTICE, "Only variable references should be yielded by reference");
- } else {
- ZVAL_MAKE_REF(value_ptr);
- }
- ZVAL_COPY(&generator->value, value_ptr);
-
- }
- } else {
- zval *value = opline->op1.zv;
-
- /* Consts, temporary variables and references need copying */
- if (IS_CONST == IS_CONST) {
- ZVAL_DUP(&generator->value, value);
- } else if (IS_CONST == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&generator->value, value);
- } else if ((IS_CONST == IS_CV || IS_CONST == IS_VAR) && Z_ISREF_P(value)) {
- ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
-
- } else {
- ZVAL_COPY_VALUE(&generator->value, value);
- if (IS_CONST == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
- }
- }
- }
- } else {
- /* If no value was specified yield null */
- ZVAL_NULL(&generator->value);
- }
-
- /* Set the new yielded key */
- if (IS_UNUSED != IS_UNUSED) {
-
- zval *key = NULL;
-
- /* Consts, temporary variables and references need copying */
- if (IS_UNUSED == IS_CONST) {
- ZVAL_DUP(&generator->key, key);
- } else if (IS_UNUSED == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&generator->key, key);
- } else if ((IS_UNUSED == IS_VAR || IS_UNUSED == IS_CV) && Z_ISREF_P(key)) {
- ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
-
- } else {
- ZVAL_COPY_VALUE(&generator->key, key);
- if (IS_UNUSED == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
- }
- }
-
- if (Z_TYPE(generator->key) == IS_LONG
- && Z_LVAL(generator->key) > generator->largest_used_integer_key
- ) {
- generator->largest_used_integer_key = Z_LVAL(generator->key);
- }
- } else {
- /* If no key was specified we use auto-increment keys */
- generator->largest_used_integer_key++;
- ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
- }
-
- if (RETURN_VALUE_USED(opline)) {
- /* If the return value of yield is used set the send
- * target and initialize it to NULL */
- generator->send_target = EX_VAR(opline->result.var);
- ZVAL_NULL(generator->send_target);
- } else {
- generator->send_target = NULL;
- }
-
- /* We increment to the next op, so we are at the correct position when the
- * generator is resumed. */
- ZEND_VM_INC_OPCODE();
-
- /* The GOTO VM uses a local opline variable. We need to set the opline
- * variable in execute_data so we don't resume at an old position. */
- SAVE_OPLINE();
-
- ZEND_VM_RETURN();
-}
-
-static int ZEND_FASTCALL ZEND_ADD_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BW_AND_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
SAVE_OPLINE();
- fast_add_function(EX_VAR(opline->result.var),
+ bitwise_and_function(EX_VAR(opline->result.var),
opline->op1.zv,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_SUB_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BW_XOR_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
SAVE_OPLINE();
- fast_sub_function(EX_VAR(opline->result.var),
+ bitwise_xor_function(EX_VAR(opline->result.var),
opline->op1.zv,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_MUL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BOOL_XOR_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
SAVE_OPLINE();
- fast_mul_function(EX_VAR(opline->result.var),
+ boolean_xor_function(EX_VAR(opline->result.var),
opline->op1.zv,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_DIV_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *container;
SAVE_OPLINE();
- fast_div_function(EX_VAR(opline->result.var),
- opline->op1.zv,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ container = opline->op1.zv;
+ zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_MOD_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_IS_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *container;
SAVE_OPLINE();
- fast_mod_function(EX_VAR(opline->result.var),
- opline->op1.zv,
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ container = opline->op1.zv;
+ zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_SL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
+ zval *container;
+ zend_free_op free_op1;
SAVE_OPLINE();
- shift_left_function(EX_VAR(opline->result.var),
- opline->op1.zv,
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+ if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+ if (IS_CONST == IS_CONST || IS_CONST == IS_TMP_VAR) {
+ zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+ }
+ container = NULL;
+ if (IS_CONST == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ }
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
+ if (IS_CONST == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ }
+
+
+ } else {
+ if (IS_CV == IS_UNUSED) {
+ zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
+ }
+ container = opline->op1.zv;
+ zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
+ }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_SR_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *container;
+
+ zval *offset;
SAVE_OPLINE();
- shift_right_function(EX_VAR(opline->result.var),
- opline->op1.zv,
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ container = opline->op1.zv;
+ offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ if ((IS_CONST != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+ UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+ zend_error(E_NOTICE, "Trying to get property of non-object");
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ } else {
+ zval *retval;
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ /* here we are sure we are dealing with an object */
+ do {
+ if (IS_CV == IS_CONST &&
+ EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
+ zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
+ zend_object *zobj = Z_OBJ_P(container);
-static int ZEND_FASTCALL ZEND_CONCAT_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ if (EXPECTED(prop_info)) {
+ retval = OBJ_PROP(zobj, prop_info->offset);
+ if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
+ }
+ } else if (EXPECTED(zobj->properties != NULL)) {
+ retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
+ if (EXPECTED(retval)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
+ }
+ }
+ }
+ retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
- SAVE_OPLINE();
- concat_function(EX_VAR(opline->result.var),
- opline->op1.zv,
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ if (retval != EX_VAR(opline->result.var)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ }
+ } while (0);
+ }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_IS_IDENTICAL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
-
- SAVE_OPLINE();
- fast_is_identical_function(EX_VAR(opline->result.var),
- opline->op1.zv,
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_IS_NOT_IDENTICAL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- zval *result = EX_VAR(opline->result.var);
-
- SAVE_OPLINE();
- fast_is_not_identical_function(result,
- opline->op1.zv,
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_IS_EQUAL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- zval *result = EX_VAR(opline->result.var);
-
- SAVE_OPLINE();
- fast_equal_function(result,
- opline->op1.zv,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_IS_NOT_EQUAL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- zval *result = EX_VAR(opline->result.var);
-
- SAVE_OPLINE();
- fast_not_equal_function(result,
- opline->op1.zv,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_IS_SMALLER_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- zval *result = EX_VAR(opline->result.var);
-
- SAVE_OPLINE();
- fast_is_smaller_function(result,
- opline->op1.zv,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_IS_SMALLER_OR_EQUAL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- zval *result = EX_VAR(opline->result.var);
-
- SAVE_OPLINE();
- fast_is_smaller_or_equal_function(result,
- opline->op1.zv,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_BW_OR_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
-
- SAVE_OPLINE();
- bitwise_or_function(EX_VAR(opline->result.var),
- opline->op1.zv,
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_BW_AND_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
-
- SAVE_OPLINE();
- bitwise_and_function(EX_VAR(opline->result.var),
- opline->op1.zv,
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_BW_XOR_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
-
- SAVE_OPLINE();
- bitwise_xor_function(EX_VAR(opline->result.var),
- opline->op1.zv,
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_BOOL_XOR_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
-
- SAVE_OPLINE();
- boolean_xor_function(EX_VAR(opline->result.var),
- opline->op1.zv,
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- zval *container;
-
- SAVE_OPLINE();
- container = opline->op1.zv;
- zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
-
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_DIM_IS_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- zval *container;
-
- SAVE_OPLINE();
- container = opline->op1.zv;
- zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
-
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *container;
- zend_free_op free_op1;
-
- SAVE_OPLINE();
-
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- if (IS_CONST == IS_CONST || IS_CONST == IS_TMP_VAR) {
- zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
- }
- container = NULL;
- if (IS_CONST == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
- if (IS_CONST == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
-
-
- } else {
- if (IS_CV == IS_UNUSED) {
- zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
- }
- container = opline->op1.zv;
- zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
-
-
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- zval *container;
-
- zval *offset;
-
- SAVE_OPLINE();
- container = opline->op1.zv;
- offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
-
- if ((IS_CONST != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
- UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
- zend_error(E_NOTICE, "Trying to get property of non-object");
- ZVAL_NULL(EX_VAR(opline->result.var));
- } else {
- zval *retval;
-
- /* here we are sure we are dealing with an object */
- do {
- if (IS_CV == IS_CONST &&
- EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
- zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
- zend_object *zobj = Z_OBJ_P(container);
-
- if (EXPECTED(prop_info)) {
- retval = OBJ_PROP(zobj, prop_info->offset);
- if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- } else if (EXPECTED(zobj->properties != NULL)) {
- retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
- if (EXPECTED(retval)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- }
- }
-
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
-
- if (retval != EX_VAR(opline->result.var)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- }
- } while (0);
- }
-
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
result = 0;
if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
- if (IS_CV == IS_CV || IS_CV == IS_VAR) {
+ if (IS_CV & (IS_CV|IS_VAR)) {
ZVAL_DEREF(offset);
}
if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_BW_NOT_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_CONST_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
+
+ zval *container;
+ zend_free_op free_op2;
+ zval *offset;
SAVE_OPLINE();
- bitwise_not_function(EX_VAR(opline->result.var),
- _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ container = opline->op1.zv;
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-static int ZEND_FASTCALL ZEND_BOOL_NOT_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
+ if ((IS_CONST != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+ UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+ zend_error(E_NOTICE, "Trying to get property of non-object");
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ } else {
+ zval *retval;
- SAVE_OPLINE();
- boolean_not_function(EX_VAR(opline->result.var),
- _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ /* here we are sure we are dealing with an object */
+ do {
+ if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
+ EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
+ zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
+ zend_object *zobj = Z_OBJ_P(container);
-static int ZEND_FASTCALL ZEND_ECHO_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *z;
+ if (EXPECTED(prop_info)) {
+ retval = OBJ_PROP(zobj, prop_info->offset);
+ if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
+ }
+ } else if (EXPECTED(zobj->properties != NULL)) {
+ retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
+ if (EXPECTED(retval)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
+ }
+ }
+ }
- SAVE_OPLINE();
- z = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+ retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
- zend_print_variable(z TSRMLS_CC);
+ if (retval != EX_VAR(opline->result.var)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ }
+ } while (0);
+ }
+
+ zval_ptr_dtor_nogc(free_op2);
- zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_PRINT_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_CONST_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- ZVAL_LONG(EX_VAR(opline->result.var), 1);
- return ZEND_ECHO_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_JMPZ_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *val;
+ zval *container;
+ zend_free_op free_op2;
+ zval *offset;
SAVE_OPLINE();
- val = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
- if (IS_TMP_VAR == IS_TMP_VAR) {
- if (Z_TYPE_P(val) == IS_TRUE) {
- ZEND_VM_SET_OPCODE(opline + 1);
- ZEND_VM_CONTINUE();
- } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
- ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
- ZEND_VM_CONTINUE();
- }
- }
+ container = opline->op1.zv;
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (i_zend_is_true(val TSRMLS_CC)) {
- opline++;
+ if ((IS_CONST != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+ UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
} else {
- opline = opline->op2.jmp_addr;
- }
- zval_ptr_dtor_nogc(free_op1);
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- ZEND_VM_JMP(opline);
-}
+ zval *retval;
-static int ZEND_FASTCALL ZEND_JMPNZ_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *val;
+ /* here we are sure we are dealing with an object */
+ do {
+ if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
+ EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
+ zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
+ zend_object *zobj = Z_OBJ_P(container);
- SAVE_OPLINE();
- val = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+ if (EXPECTED(prop_info)) {
+ retval = OBJ_PROP(zobj, prop_info->offset);
+ if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
+ }
+ } else if (EXPECTED(zobj->properties != NULL)) {
+ retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
+ if (EXPECTED(retval)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
+ }
+ }
+ }
- if (IS_TMP_VAR == IS_TMP_VAR) {
- if (Z_TYPE_P(val) == IS_TRUE) {
- ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
- ZEND_VM_CONTINUE();
- } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
- ZEND_VM_SET_OPCODE(opline + 1);
- ZEND_VM_CONTINUE();
- }
- }
+ retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
- if (i_zend_is_true(val TSRMLS_CC)) {
- opline = opline->op2.jmp_addr;
- } else {
- opline++;
- }
- zval_ptr_dtor_nogc(free_op1);
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
+ if (retval != EX_VAR(opline->result.var)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ }
+ } while (0);
}
- ZEND_VM_JMP(opline);
-}
-
-static int ZEND_FASTCALL ZEND_JMPZNZ_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *val;
-
- SAVE_OPLINE();
- val = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- if (IS_TMP_VAR == IS_TMP_VAR) {
- if (EXPECTED(Z_TYPE_P(val) == IS_TRUE)) {
- ZEND_VM_SET_RELATIVE_OPCODE(opline, opline->extended_value);
- ZEND_VM_CONTINUE();
- } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
- ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
- ZEND_VM_CONTINUE();
- }
- }
+ zval_ptr_dtor_nogc(free_op2);
- if (i_zend_is_true(val TSRMLS_CC)) {
- opline = (zend_op*)(((char*)opline) + opline->extended_value);
- } else {
- opline = opline->op2.jmp_addr;
- }
- zval_ptr_dtor_nogc(free_op1);
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- ZEND_VM_JMP(opline);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_JMPZ_EX_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CONST_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *val;
+ zval *container;
- SAVE_OPLINE();
- val = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+ if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+ /* Behave like FETCH_OBJ_W */
+ zend_free_op free_op1, free_op2;
+ zval *property;
- if (IS_TMP_VAR == IS_TMP_VAR) {
- if (Z_TYPE_P(val) == IS_TRUE) {
- ZVAL_TRUE(EX_VAR(opline->result.var));
- ZEND_VM_SET_OPCODE(opline + 1);
- ZEND_VM_CONTINUE();
- } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
- ZVAL_FALSE(EX_VAR(opline->result.var));
- ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
- ZEND_VM_CONTINUE();
+ SAVE_OPLINE();
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ container = NULL;
+
+ if (IS_CONST == IS_CONST || IS_CONST == IS_TMP_VAR) {
+ zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+ }
+ if (IS_CONST == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+ }
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CONST, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ if (IS_CONST == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
- }
- if (i_zend_is_true(val TSRMLS_CC)) {
- zval_ptr_dtor_nogc(free_op1);
- ZVAL_TRUE(EX_VAR(opline->result.var));
- opline++;
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
} else {
- zval_ptr_dtor_nogc(free_op1);
- ZVAL_FALSE(EX_VAR(opline->result.var));
- opline = opline->op2.jmp_addr;
+ return ZEND_FETCH_OBJ_R_SPEC_CONST_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- ZEND_VM_JMP(opline);
}
-static int ZEND_FASTCALL ZEND_JMPNZ_EX_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *val;
+ zval *function_name;
+ zend_class_entry *ce;
+ zend_object *object;
+ zend_function *fbc;
SAVE_OPLINE();
- val = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- if (IS_TMP_VAR == IS_TMP_VAR) {
- if (Z_TYPE_P(val) == IS_TRUE) {
- ZVAL_TRUE(EX_VAR(opline->result.var));
- ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
- ZEND_VM_CONTINUE();
- } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
- ZVAL_FALSE(EX_VAR(opline->result.var));
- ZEND_VM_SET_OPCODE(opline + 1);
- ZEND_VM_CONTINUE();
+ if (IS_CONST == IS_CONST) {
+ /* no function found. try a static method in class */
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv));
+ } else {
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op1.zv), opline->op1.zv + 1, ZEND_FETCH_CLASS_DEFAULT TSRMLS_CC);
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ if (UNEXPECTED(ce == NULL)) {
+ zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
+ }
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op1.zv), ce);
}
- }
- if (i_zend_is_true(val TSRMLS_CC)) {
- ZVAL_TRUE(EX_VAR(opline->result.var));
- opline = opline->op2.jmp_addr;
} else {
- ZVAL_FALSE(EX_VAR(opline->result.var));
- opline++;
- }
- zval_ptr_dtor_nogc(free_op1);
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
+ ce = Z_CE_P(EX_VAR(opline->op1.var));
}
- ZEND_VM_JMP(opline);
-}
-
-static int ZEND_FASTCALL ZEND_RETURN_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *retval_ptr;
- zend_free_op free_op1;
- SAVE_OPLINE();
- retval_ptr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+ if (IS_CONST == IS_CONST &&
+ (IS_TMP_VAR|IS_VAR) == IS_CONST &&
+ CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ fbc = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ } else if (IS_CONST != IS_CONST &&
+ (IS_TMP_VAR|IS_VAR) == IS_CONST &&
+ (fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce))) {
+ /* do nothing */
+ } else if ((IS_TMP_VAR|IS_VAR) != IS_UNUSED) {
+ zend_free_op free_op2;
- if (!EX(return_value)) {
- zval_ptr_dtor_nogc(free_op1);
- } else {
- if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
- if (IS_TMP_VAR == IS_CONST) {
- if (UNEXPECTED(Z_OPT_COPYABLE_P(EX(return_value)))) {
- zval_copy_ctor_func(EX(return_value));
+ function_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+ if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
}
- }
- } else if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) && Z_ISREF_P(retval_ptr)) {
- ZVAL_COPY(EX(return_value), Z_REFVAL_P(retval_ptr));
+ zend_error_noreturn(E_ERROR, "Function name must be a string");
+ }
+ }
+ if (ce->get_static_method) {
+ fbc = ce->get_static_method(ce, Z_STR_P(function_name) TSRMLS_CC);
} else {
- ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
- if (IS_TMP_VAR == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(retval_ptr)) Z_ADDREF_P(retval_ptr);
- }
+ fbc = zend_std_get_static_method(ce, Z_STR_P(function_name), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
}
- }
- return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_RETURN_BY_REF_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *retval_ptr;
- zend_free_op free_op1;
-
- SAVE_OPLINE();
-
- do {
- if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR ||
- (IS_TMP_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_VALUE)) {
- /* Not supposed to happen, but we'll allow it */
- zend_error(E_NOTICE, "Only variable references should be returned by reference");
-
- retval_ptr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- if (!EX(return_value)) {
- if (IS_TMP_VAR == IS_TMP_VAR) {
- zval_ptr_dtor_nogc(free_op1);
- }
+ if (UNEXPECTED(fbc == NULL)) {
+ zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name->val, Z_STRVAL_P(function_name));
+ }
+ if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
+ EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
+ EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0)) {
+ if (IS_CONST == IS_CONST) {
+ CACHE_PTR(Z_CACHE_SLOT_P(function_name), fbc);
} else {
- ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
- Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
- if (IS_TMP_VAR != IS_TMP_VAR) {
- zval_opt_copy_ctor_no_imm(EX(return_value));
- }
+ CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), ce, fbc);
}
- break;
- }
-
- retval_ptr = NULL;
-
- if (IS_TMP_VAR == IS_VAR && UNEXPECTED(retval_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot return string offsets by reference");
}
-
- if (IS_TMP_VAR == IS_VAR) {
- if (retval_ptr == &EG(uninitialized_zval) ||
- (opline->extended_value == ZEND_RETURNS_FUNCTION &&
- !(Z_VAR_FLAGS_P(retval_ptr) & IS_VAR_RET_REF))) {
- zend_error(E_NOTICE, "Only variable references should be returned by reference");
- if (EX(return_value)) {
- ZVAL_NEW_REF(EX(return_value), retval_ptr);
- Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
- if (Z_REFCOUNTED_P(retval_ptr)) Z_ADDREF_P(retval_ptr);
- }
- break;
- }
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+ zval_ptr_dtor_nogc(free_op2);
}
-
- if (EX(return_value)) {
- ZVAL_MAKE_REF(retval_ptr);
- Z_ADDREF_P(retval_ptr);
- ZVAL_REF(EX(return_value), Z_REF_P(retval_ptr));
- Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
+ } else {
+ if (UNEXPECTED(ce->constructor == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot call constructor");
}
- } while (0);
-
- return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_THROW_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *value;
- zend_free_op free_op1;
-
- SAVE_OPLINE();
- value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
- if (IS_TMP_VAR == IS_CONST || UNEXPECTED(Z_TYPE_P(value) != IS_OBJECT)) {
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
+ if (Z_OBJ(EX(This)) && Z_OBJ(EX(This))->ce != ce->constructor->common.scope && (ce->constructor->common.fn_flags & ZEND_ACC_PRIVATE)) {
+ zend_error_noreturn(E_ERROR, "Cannot call private %s::__construct()", ce->name->val);
}
- zend_error_noreturn(E_ERROR, "Can only throw objects");
+ fbc = ce->constructor;
}
- zend_exception_save(TSRMLS_C);
- if (IS_TMP_VAR != IS_TMP_VAR) {
- if (Z_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+ object = NULL;
+ if (!(fbc->common.fn_flags & ZEND_ACC_STATIC)) {
+ if (Z_OBJ(EX(This))) {
+ object = Z_OBJ(EX(This));
+ GC_REFCOUNT(object)++;
+ }
+ if (!object ||
+ !instanceof_function(object->ce, ce TSRMLS_CC)) {
+ /* We are calling method of the other (incompatible) class,
+ but passing $this. This is done for compatibility with php-4. */
+ if (fbc->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
+ zend_error(
+ object ? E_DEPRECATED : E_STRICT,
+ "Non-static method %s::%s() should not be called statically%s",
+ fbc->common.scope->name->val, fbc->common.function_name->val,
+ object ? ", assuming $this from incompatible context" : "");
+ } else {
+ /* An internal function assumes $this is present and won't check that. So PHP would crash by allowing the call. */
+ zend_error_noreturn(
+ E_ERROR,
+ "Non-static method %s::%s() cannot be called statically%s",
+ fbc->common.scope->name->val, fbc->common.function_name->val,
+ object ? ", assuming $this from incompatible context" : "");
+ }
+ }
}
- zend_throw_exception_object(value TSRMLS_CC);
- zend_exception_restore(TSRMLS_C);
-
- HANDLE_EXCEPTION();
-}
-
-static int ZEND_FASTCALL ZEND_SEND_VAL_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *value, *arg;
- zend_free_op free_op1;
-
- SAVE_OPLINE();
- value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
- ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
- ZVAL_COPY_VALUE(arg, value);
- if (IS_TMP_VAR == IS_CONST) {
- if (UNEXPECTED(Z_OPT_COPYABLE_P(arg))) {
- zval_copy_ctor_func(arg);
+ if (IS_CONST != IS_CONST) {
+ /* previous opcode is ZEND_FETCH_CLASS */
+ if ((opline-1)->extended_value == ZEND_FETCH_CLASS_PARENT || (opline-1)->extended_value == ZEND_FETCH_CLASS_SELF) {
+ ce = EX(called_scope);
}
}
- ZEND_VM_NEXT_OPCODE();
-}
-static int ZEND_FASTCALL ZEND_SEND_VAL_EX_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *value, *arg;
- zend_free_op free_op1;
+ EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
+ fbc, opline->extended_value, ce, object, EX(call) TSRMLS_CC);
- SAVE_OPLINE();
- if (ARG_MUST_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
- zend_error_noreturn(E_ERROR, "Cannot pass parameter %d by reference", opline->op2.num);
- }
- value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
- ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
- ZVAL_COPY_VALUE(arg, value);
- if (IS_TMP_VAR == IS_CONST) {
- if (UNEXPECTED(Z_OPT_COPYABLE_P(arg))) {
- zval_copy_ctor_func(arg);
- }
+ if ((IS_TMP_VAR|IS_VAR) == IS_UNUSED) {
+ EX(call)->return_value = NULL;
}
+
+ CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_BOOL_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_CASE_SPEC_CONST_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *retval = EX_VAR(opline->result.var);
+ zend_free_op free_op2;
+ zval *result = EX_VAR(opline->result.var);
SAVE_OPLINE();
- /* PHP 3.0 returned "" for false and 1 for true, here we use 0 and 1 for now */
- ZVAL_BOOL(retval, i_zend_is_true(_get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1) TSRMLS_CC));
- zval_ptr_dtor_nogc(free_op1);
+ fast_equal_function(result,
+ opline->op1.zv,
+ _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_CLONE_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *obj;
- zend_class_entry *ce;
- zend_function *clone;
- zend_object_clone_obj_t clone_call;
- SAVE_OPLINE();
- obj = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+ zval *expr_ptr, new_expr;
- if (IS_TMP_VAR == IS_CONST ||
- (IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(obj) != IS_OBJECT))) {
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
+ SAVE_OPLINE();
+ if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) &&
+ (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
+ expr_ptr = NULL;
+ if (IS_CONST == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
}
- zend_error_noreturn(E_ERROR, "__clone method called on non-object");
- }
+ ZVAL_MAKE_REF(expr_ptr);
+ Z_ADDREF_P(expr_ptr);
- ce = Z_OBJCE_P(obj);
- clone = ce ? ce->clone : NULL;
- clone_call = Z_OBJ_HT_P(obj)->clone_obj;
- if (UNEXPECTED(clone_call == NULL)) {
- if (ce) {
- zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object of class %s", ce->name->val);
- } else {
- zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object");
+ } else {
+ expr_ptr = opline->op1.zv;
+ if (IS_CONST == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&new_expr, expr_ptr);
+ expr_ptr = &new_expr;
+ } else if (IS_CONST == IS_CONST) {
+ if (!Z_IMMUTABLE_P(expr_ptr)) {
+ ZVAL_DUP(&new_expr, expr_ptr);
+ expr_ptr = &new_expr;
+ }
+ } else if ((IS_CONST == IS_CV || IS_CONST == IS_VAR) && Z_ISREF_P(expr_ptr)) {
+ expr_ptr = Z_REFVAL_P(expr_ptr);
+ if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
+
+ } else if (IS_CONST == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
+ Z_ADDREF_P(expr_ptr);
}
}
- if (ce && clone) {
- if (clone->op_array.fn_flags & ZEND_ACC_PRIVATE) {
- /* Ensure that if we're calling a private function, we're allowed to do so.
- */
- if (UNEXPECTED(ce != EG(scope))) {
- zend_error_noreturn(E_ERROR, "Call to private %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
- }
- } else if ((clone->common.fn_flags & ZEND_ACC_PROTECTED)) {
- /* Ensure that if we're calling a protected function, we're allowed to do so.
- */
- if (UNEXPECTED(!zend_check_protected(zend_get_function_root_class(clone), EG(scope)))) {
- zend_error_noreturn(E_ERROR, "Call to protected %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
- }
+ if ((IS_TMP_VAR|IS_VAR) != IS_UNUSED) {
+ zend_free_op free_op2;
+ zval *offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ zend_string *str;
+ zend_ulong hval;
+
+add_again:
+ switch (Z_TYPE_P(offset)) {
+ case IS_DOUBLE:
+ hval = zend_dval_to_lval(Z_DVAL_P(offset));
+ goto num_index;
+ case IS_LONG:
+ hval = Z_LVAL_P(offset);
+num_index:
+ zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
+ break;
+ case IS_STRING:
+ str = Z_STR_P(offset);
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+ if (ZEND_HANDLE_NUMERIC(str, hval)) {
+ goto num_index;
+ }
+ }
+str_index:
+ zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
+ break;
+ case IS_NULL:
+ str = STR_EMPTY_ALLOC();
+ goto str_index;
+ case IS_FALSE:
+ hval = 0;
+ goto num_index;
+ case IS_TRUE:
+ hval = 1;
+ goto num_index;
+ case IS_REFERENCE:
+ offset = Z_REFVAL_P(offset);
+ goto add_again;
+ break;
+ default:
+ zend_error(E_WARNING, "Illegal offset type");
+ zval_ptr_dtor(expr_ptr);
+ /* do nothing */
+ break;
}
+ zval_ptr_dtor_nogc(free_op2);
+ } else {
+ zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
}
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- if (EXPECTED(EG(exception) == NULL)) {
- ZVAL_OBJ(EX_VAR(opline->result.var), clone_call(obj TSRMLS_CC));
- if (!RETURN_VALUE_USED(opline) || UNEXPECTED(EG(exception) != NULL)) {
- OBJ_RELEASE(Z_OBJ_P(EX_VAR(opline->result.var)));
+static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_CONST_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ zval *array;
+ uint32_t size;
+ USE_OPLINE
+
+ array = EX_VAR(opline->result.var);
+ if (IS_CONST != IS_UNUSED) {
+ size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
+ } else {
+ size = 0;
+ }
+ ZVAL_NEW_ARR(array);
+ zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
+
+ if (IS_CONST != IS_UNUSED) {
+ /* Explicitly initialize array as not-packed if flag is set */
+ if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
+ zend_hash_real_init(Z_ARRVAL_P(array), 0);
}
}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (IS_CONST == IS_UNUSED) {
+ ZEND_VM_NEXT_OPCODE();
+#if 0 || IS_CONST != IS_UNUSED
+ } else {
+ return ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+#endif
+ }
}
-static int ZEND_FASTCALL ZEND_CAST_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CONST_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *expr;
- zval *result = EX_VAR(opline->result.var);
+ zend_free_op free_op2;
+ zval *container;
+ int result;
+ zend_ulong hval;
+ zval *offset;
SAVE_OPLINE();
- expr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+ container = opline->op1.zv;
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- switch (opline->extended_value) {
- case IS_NULL:
- /* This code is taken from convert_to_null. However, it does not seems very useful,
- * because a conversion to null always results in the same value. This could only
- * be relevant if a cast_object handler for IS_NULL has some kind of side-effect. */
-#if 0
- if (IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) {
- ZVAL_DEREF(expr);
+ if (IS_CONST != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
+ HashTable *ht = Z_ARRVAL_P(container);
+ zval *value;
+ zend_string *str;
+
+isset_again:
+ if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
+ str = Z_STR_P(offset);
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+ if (ZEND_HANDLE_NUMERIC(str, hval)) {
+ goto num_index_prop;
+ }
}
- if (Z_TYPE_P(expr) == IS_OBJECT && Z_OBJ_HT_P(expr)->cast_object) {
- if (Z_OBJ_HT_P(expr)->cast_object(expr, result, IS_NULL TSRMLS_CC) == SUCCESS) {
+str_index_prop:
+ value = zend_hash_find_ind(ht, str);
+ } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
+ hval = Z_LVAL_P(offset);
+num_index_prop:
+ value = zend_hash_index_find(ht, hval);
+ } else {
+ switch (Z_TYPE_P(offset)) {
+ case IS_DOUBLE:
+ hval = zend_dval_to_lval(Z_DVAL_P(offset));
+ goto num_index_prop;
+ case IS_NULL:
+ str = STR_EMPTY_ALLOC();
+ goto str_index_prop;
+ case IS_FALSE:
+ hval = 0;
+ goto num_index_prop;
+ case IS_TRUE:
+ hval = 1;
+ goto num_index_prop;
+ case IS_RESOURCE:
+ hval = Z_RES_HANDLE_P(offset);
+ goto num_index_prop;
+ case IS_REFERENCE:
+ offset = Z_REFVAL_P(offset);
+ goto isset_again;
+ default:
+ zend_error(E_WARNING, "Illegal offset type in isset or empty");
+ value = NULL;
break;
- }
}
-#endif
+ }
- ZVAL_NULL(result);
- break;
- case _IS_BOOL:
- ZVAL_BOOL(result, zend_is_true(expr TSRMLS_CC));
- break;
- case IS_LONG:
- ZVAL_LONG(result, zval_get_long(expr));
- break;
- case IS_DOUBLE:
- ZVAL_DOUBLE(result, zval_get_double(expr));
- break;
- case IS_STRING:
- ZVAL_STR(result, zval_get_string(expr));
- break;
- default:
- /* If value is already of correct type, return it directly */
- if (Z_TYPE_P(expr) == opline->extended_value) {
- ZVAL_COPY_VALUE(result, expr);
- if (IS_TMP_VAR == IS_CONST) {
- if (UNEXPECTED(Z_OPT_COPYABLE_P(result))) {
- zval_copy_ctor_func(result);
- }
- } else if (IS_TMP_VAR != IS_TMP_VAR) {
- if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
- }
+ if (opline->extended_value & ZEND_ISSET) {
+ /* > IS_NULL means not IS_UNDEF and not IS_NULL */
+ result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
+ (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
+ } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+ result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
+ }
+ } else if (IS_CONST == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
+ result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
+ } else {
+ zend_error(E_NOTICE, "Trying to check element of non-array");
+ result = 0;
+ }
+ if ((opline->extended_value & ZEND_ISSET) == 0) {
+ result = !result;
+ }
+ } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
+ zval tmp;
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ result = 0;
+ if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
+ if ((IS_TMP_VAR|IS_VAR) & (IS_CV|IS_VAR)) {
+ ZVAL_DEREF(offset);
}
-
- if (opline->extended_value == IS_ARRAY) {
- if (Z_TYPE_P(expr) != IS_OBJECT) {
- ZVAL_NEW_ARR(result);
- zend_hash_init(Z_ARRVAL_P(result), 8, NULL, ZVAL_PTR_DTOR, 0);
- if (Z_TYPE_P(expr) != IS_NULL) {
- expr = zend_hash_index_add_new(Z_ARRVAL_P(result), 0, expr);
- if (IS_TMP_VAR == IS_CONST) {
- if (UNEXPECTED(Z_OPT_COPYABLE_P(expr))) {
- zval_copy_ctor_func(expr);
- }
- } else {
- if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
- }
- }
- } else {
- ZVAL_COPY_VALUE(result, expr);
- Z_ADDREF_P(result);
- convert_to_array(result);
- }
- } else {
- if (Z_TYPE_P(expr) != IS_ARRAY) {
- object_init(result);
- if (Z_TYPE_P(expr) != IS_NULL) {
- expr = zend_hash_str_add_new(Z_OBJPROP_P(result), "scalar", sizeof("scalar")-1, expr);
- if (IS_TMP_VAR == IS_CONST) {
- if (UNEXPECTED(Z_OPT_COPYABLE_P(expr))) {
- zval_copy_ctor_func(expr);
- }
- } else {
- if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
- }
- }
- } else {
- ZVAL_COPY_VALUE(result, expr);
- zval_opt_copy_ctor(result);
- convert_to_object(result);
+ if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
+ || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
+ && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
+ ZVAL_DUP(&tmp, offset);
+ convert_to_long(&tmp);
+ offset = &tmp;
+ }
+ }
+ if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
+ if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
+ if ((opline->extended_value & ZEND_ISSET) ||
+ Z_STRVAL_P(container)[offset->value.lval] != '0') {
+ result = 1;
}
}
+ }
+ if ((opline->extended_value & ZEND_ISSET) == 0) {
+ result = !result;
+ }
+ } else {
+ result = ((opline->extended_value & ZEND_ISSET) == 0);
}
- zval_ptr_dtor_nogc(free_op1);
+ zval_ptr_dtor_nogc(free_op2);
+ ZVAL_BOOL(EX_VAR(opline->result.var), result);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INCLUDE_OR_EVAL_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CONST_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_op_array *new_op_array=NULL;
- zend_free_op free_op1;
- zval *inc_filename;
- zval tmp_inc_filename;
- zend_bool failure_retval=0;
+ zend_free_op free_op2;
+ zval *container;
+ int result;
+ zval *offset;
SAVE_OPLINE();
- inc_filename = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
- ZVAL_UNDEF(&tmp_inc_filename);
- if (Z_TYPE_P(inc_filename) != IS_STRING) {
- ZVAL_STR(&tmp_inc_filename, zval_get_string(inc_filename));
- inc_filename = &tmp_inc_filename;
- }
+ container = opline->op1.zv;
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (opline->extended_value != ZEND_EVAL && strlen(Z_STRVAL_P(inc_filename)) != Z_STRLEN_P(inc_filename)) {
- if (opline->extended_value == ZEND_INCLUDE_ONCE || opline->extended_value == ZEND_INCLUDE) {
- zend_message_dispatcher(ZMSG_FAILED_INCLUDE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
+ if (IS_CONST == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
+ result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
} else {
- zend_message_dispatcher(ZMSG_FAILED_REQUIRE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
+ zend_error(E_NOTICE, "Trying to check property of non-object");
+ result = 0;
+ }
+ if ((opline->extended_value & ZEND_ISSET) == 0) {
+ result = !result;
}
} else {
- switch (opline->extended_value) {
- case ZEND_INCLUDE_ONCE:
- case ZEND_REQUIRE_ONCE: {
- zend_file_handle file_handle;
- char *resolved_path;
+ result = ((opline->extended_value & ZEND_ISSET) == 0);
+ }
- resolved_path = zend_resolve_path(Z_STRVAL_P(inc_filename), (int)Z_STRLEN_P(inc_filename) TSRMLS_CC);
- if (resolved_path) {
- failure_retval = zend_hash_str_exists(&EG(included_files), resolved_path, (int)strlen(resolved_path));
- } else {
- resolved_path = Z_STRVAL_P(inc_filename);
- }
+ zval_ptr_dtor_nogc(free_op2);
+ ZVAL_BOOL(EX_VAR(opline->result.var), result);
- if (failure_retval) {
- /* do nothing, file already included */
- } else if (SUCCESS == zend_stream_open(resolved_path, &file_handle TSRMLS_CC)) {
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- if (!file_handle.opened_path) {
- file_handle.opened_path = estrdup(resolved_path);
- }
+static int ZEND_FASTCALL ZEND_BW_NOT_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
- if (zend_hash_str_add_empty_element(&EG(included_files), file_handle.opened_path, (int)strlen(file_handle.opened_path))) {
- new_op_array = zend_compile_file(&file_handle, (opline->extended_value==ZEND_INCLUDE_ONCE?ZEND_INCLUDE:ZEND_REQUIRE) TSRMLS_CC);
- zend_destroy_file_handle(&file_handle TSRMLS_CC);
- } else {
- zend_file_handle_dtor(&file_handle TSRMLS_CC);
- failure_retval=1;
- }
- } else {
- if (opline->extended_value == ZEND_INCLUDE_ONCE) {
- zend_message_dispatcher(ZMSG_FAILED_INCLUDE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
- } else {
- zend_message_dispatcher(ZMSG_FAILED_REQUIRE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
- }
- }
- if (resolved_path != Z_STRVAL_P(inc_filename)) {
- efree(resolved_path);
- }
- }
- break;
- case ZEND_INCLUDE:
- case ZEND_REQUIRE:
- new_op_array = compile_filename(opline->extended_value, inc_filename TSRMLS_CC);
- break;
- case ZEND_EVAL: {
- char *eval_desc = zend_make_compiled_string_description("eval()'d code" TSRMLS_CC);
+ SAVE_OPLINE();
+ bitwise_not_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- new_op_array = zend_compile_string(inc_filename, eval_desc TSRMLS_CC);
- efree(eval_desc);
- }
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
- }
- }
- if (Z_TYPE(tmp_inc_filename) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp_inc_filename));
- }
+static int ZEND_FASTCALL ZEND_BOOL_NOT_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+
+ SAVE_OPLINE();
+ boolean_not_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- } else if (EXPECTED(new_op_array != NULL)) {
- zval *return_value = NULL;
- zend_execute_data *call;
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- if (RETURN_VALUE_USED(opline)) {
- return_value = EX_VAR(opline->result.var);
- }
+static int ZEND_FASTCALL ZEND_ECHO_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+ zval *z;
- new_op_array->scope = EG(scope); /* ??? */
+ SAVE_OPLINE();
+ z = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- call = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_CODE,
- (zend_function*)new_op_array, 0, EX(called_scope), Z_OBJ(EX(This)), NULL TSRMLS_CC);
+ zend_print_variable(z TSRMLS_CC);
- if (EX(symbol_table)) {
- call->symbol_table = EX(symbol_table);
- } else {
- call->symbol_table = zend_rebuild_symbol_table(TSRMLS_C);
- }
+ zval_ptr_dtor_nogc(free_op1);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- call->prev_execute_data = execute_data;
- i_init_code_execute_data(call, new_op_array, return_value TSRMLS_CC);
- if (EXPECTED(zend_execute_ex == execute_ex)) {
- ZEND_VM_ENTER();
- } else {
- ZEND_ADD_CALL_FLAG(call, ZEND_CALL_TOP);
- zend_execute_ex(call TSRMLS_CC);
- }
+static int ZEND_FASTCALL ZEND_PRINT_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- destroy_op_array(new_op_array TSRMLS_CC);
- efree_size(new_op_array, sizeof(zend_op_array));
- if (UNEXPECTED(EG(exception) != NULL)) {
- zend_throw_exception_internal(NULL TSRMLS_CC);
- HANDLE_EXCEPTION();
+ ZVAL_LONG(EX_VAR(opline->result.var), 1);
+ return ZEND_ECHO_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL ZEND_JMPZ_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+ zval *val;
+
+ SAVE_OPLINE();
+ val = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+
+ if (IS_TMP_VAR == IS_TMP_VAR) {
+ if (Z_TYPE_P(val) == IS_TRUE) {
+ ZEND_VM_SET_OPCODE(opline + 1);
+ ZEND_VM_CONTINUE();
+ } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+ ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+ ZEND_VM_CONTINUE();
}
+ }
- } else if (RETURN_VALUE_USED(opline)) {
- ZVAL_BOOL(EX_VAR(opline->result.var), failure_retval);
+ if (i_zend_is_true(val TSRMLS_CC)) {
+ opline++;
+ } else {
+ opline = opline->op2.jmp_addr;
}
- ZEND_VM_NEXT_OPCODE();
+ zval_ptr_dtor_nogc(free_op1);
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ ZEND_VM_JMP(opline);
}
-static int ZEND_FASTCALL ZEND_FE_RESET_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_JMPNZ_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
- zval *array_ptr, *array_ref, iterator, tmp;
- HashTable *fe_ht;
- zend_object_iterator *iter = NULL;
- zend_class_entry *ce = NULL;
- zend_bool is_empty = 0;
+ zval *val;
SAVE_OPLINE();
+ val = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) &&
- (opline->extended_value & ZEND_FE_FETCH_BYREF)) {
- array_ptr = array_ref = NULL;
- ZVAL_DEREF(array_ptr);
- if (Z_TYPE_P(array_ptr) == IS_ARRAY) {
- SEPARATE_ARRAY(array_ptr);
- if (!Z_ISREF_P(array_ref)) {
- ZVAL_NEW_REF(array_ref, array_ref);
- array_ptr = Z_REFVAL_P(array_ref);
- }
- if (Z_REFCOUNTED_P(array_ref)) Z_ADDREF_P(array_ref);
- } else if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
- ce = Z_OBJCE_P(array_ptr);
- if (ce->get_iterator == NULL) {
- Z_ADDREF_P(array_ptr);
- }
- array_ref = array_ptr;
- } else {
- if (Z_REFCOUNTED_P(array_ref)) Z_ADDREF_P(array_ref);
+ if (IS_TMP_VAR == IS_TMP_VAR) {
+ if (Z_TYPE_P(val) == IS_TRUE) {
+ ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+ ZEND_VM_CONTINUE();
+ } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+ ZEND_VM_SET_OPCODE(opline + 1);
+ ZEND_VM_CONTINUE();
+ }
+ }
+
+ if (i_zend_is_true(val TSRMLS_CC)) {
+ opline = opline->op2.jmp_addr;
+ } else {
+ opline++;
+ }
+ zval_ptr_dtor_nogc(free_op1);
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ ZEND_VM_JMP(opline);
+}
+
+static int ZEND_FASTCALL ZEND_JMPZNZ_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+ zval *val;
+
+ SAVE_OPLINE();
+ val = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+
+ if (IS_TMP_VAR == IS_TMP_VAR) {
+ if (EXPECTED(Z_TYPE_P(val) == IS_TRUE)) {
+ ZEND_VM_SET_RELATIVE_OPCODE(opline, opline->extended_value);
+ ZEND_VM_CONTINUE();
+ } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+ ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+ ZEND_VM_CONTINUE();
+ }
+ }
+
+ if (i_zend_is_true(val TSRMLS_CC)) {
+ opline = (zend_op*)(((char*)opline) + opline->extended_value);
+ } else {
+ opline = opline->op2.jmp_addr;
+ }
+ zval_ptr_dtor_nogc(free_op1);
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ ZEND_VM_JMP(opline);
+}
+
+static int ZEND_FASTCALL ZEND_JMPZ_EX_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+ zval *val;
+
+ SAVE_OPLINE();
+ val = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+
+ if (IS_TMP_VAR == IS_TMP_VAR) {
+ if (Z_TYPE_P(val) == IS_TRUE) {
+ ZVAL_TRUE(EX_VAR(opline->result.var));
+ ZEND_VM_SET_OPCODE(opline + 1);
+ ZEND_VM_CONTINUE();
+ } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+ ZVAL_FALSE(EX_VAR(opline->result.var));
+ ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+ ZEND_VM_CONTINUE();
+ }
+ }
+
+ if (i_zend_is_true(val TSRMLS_CC)) {
+ zval_ptr_dtor_nogc(free_op1);
+ ZVAL_TRUE(EX_VAR(opline->result.var));
+ opline++;
+ } else {
+ zval_ptr_dtor_nogc(free_op1);
+ ZVAL_FALSE(EX_VAR(opline->result.var));
+ opline = opline->op2.jmp_addr;
+ }
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ ZEND_VM_JMP(opline);
+}
+
+static int ZEND_FASTCALL ZEND_JMPNZ_EX_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+ zval *val;
+
+ SAVE_OPLINE();
+ val = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+
+ if (IS_TMP_VAR == IS_TMP_VAR) {
+ if (Z_TYPE_P(val) == IS_TRUE) {
+ ZVAL_TRUE(EX_VAR(opline->result.var));
+ ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+ ZEND_VM_CONTINUE();
+ } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+ ZVAL_FALSE(EX_VAR(opline->result.var));
+ ZEND_VM_SET_OPCODE(opline + 1);
+ ZEND_VM_CONTINUE();
+ }
+ }
+ if (i_zend_is_true(val TSRMLS_CC)) {
+ ZVAL_TRUE(EX_VAR(opline->result.var));
+ opline = opline->op2.jmp_addr;
+ } else {
+ ZVAL_FALSE(EX_VAR(opline->result.var));
+ opline++;
+ }
+ zval_ptr_dtor_nogc(free_op1);
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ ZEND_VM_JMP(opline);
+}
+
+static int ZEND_FASTCALL ZEND_RETURN_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zval *retval_ptr;
+ zend_free_op free_op1;
+
+ SAVE_OPLINE();
+ retval_ptr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+
+ if (!EX(return_value)) {
+ zval_ptr_dtor_nogc(free_op1);
+ } else {
+ if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
+ if (IS_TMP_VAR == IS_CONST) {
+ if (UNEXPECTED(Z_OPT_COPYABLE_P(EX(return_value)))) {
+ zval_copy_ctor_func(EX(return_value));
+ }
+ }
+ } else if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) && Z_ISREF_P(retval_ptr)) {
+ ZVAL_COPY(EX(return_value), Z_REFVAL_P(retval_ptr));
+
+ } else {
+ ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
+ if (IS_TMP_VAR == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(retval_ptr)) Z_ADDREF_P(retval_ptr);
+ }
+ }
+ }
+ return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL ZEND_RETURN_BY_REF_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zval *retval_ptr;
+ zend_free_op free_op1;
+
+ SAVE_OPLINE();
+
+ do {
+ if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR ||
+ (IS_TMP_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_VALUE)) {
+ /* Not supposed to happen, but we'll allow it */
+ zend_error(E_NOTICE, "Only variable references should be returned by reference");
+
+ retval_ptr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+ if (!EX(return_value)) {
+ if (IS_TMP_VAR == IS_TMP_VAR) {
+ zval_ptr_dtor_nogc(free_op1);
+ }
+ } else {
+ ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
+ Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
+ if (IS_TMP_VAR != IS_TMP_VAR) {
+ zval_opt_copy_ctor_no_imm(EX(return_value));
+ }
+ }
+ break;
+ }
+
+ retval_ptr = NULL;
+
+ if (IS_TMP_VAR == IS_VAR && UNEXPECTED(retval_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot return string offsets by reference");
+ }
+
+ if (IS_TMP_VAR == IS_VAR) {
+ if (retval_ptr == &EG(uninitialized_zval) ||
+ (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+ !(Z_VAR_FLAGS_P(retval_ptr) & IS_VAR_RET_REF))) {
+ zend_error(E_NOTICE, "Only variable references should be returned by reference");
+ if (EX(return_value)) {
+ ZVAL_NEW_REF(EX(return_value), retval_ptr);
+ Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
+ if (Z_REFCOUNTED_P(retval_ptr)) Z_ADDREF_P(retval_ptr);
+ }
+ break;
+ }
+ }
+
+ if (EX(return_value)) {
+ ZVAL_MAKE_REF(retval_ptr);
+ Z_ADDREF_P(retval_ptr);
+ ZVAL_REF(EX(return_value), Z_REF_P(retval_ptr));
+ Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
+ }
+ } while (0);
+
+ return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL ZEND_THROW_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zval *value;
+ zend_free_op free_op1;
+
+ SAVE_OPLINE();
+ value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+
+ if (IS_TMP_VAR == IS_CONST || UNEXPECTED(Z_TYPE_P(value) != IS_OBJECT)) {
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ zend_error_noreturn(E_ERROR, "Can only throw objects");
+ }
+
+ zend_exception_save(TSRMLS_C);
+ if (IS_TMP_VAR != IS_TMP_VAR) {
+ if (Z_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+ }
+
+ zend_throw_exception_object(value TSRMLS_CC);
+ zend_exception_restore(TSRMLS_C);
+
+ HANDLE_EXCEPTION();
+}
+
+static int ZEND_FASTCALL ZEND_SEND_VAL_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zval *value, *arg;
+ zend_free_op free_op1;
+
+ SAVE_OPLINE();
+ value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+ arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
+ ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
+ ZVAL_COPY_VALUE(arg, value);
+ if (IS_TMP_VAR == IS_CONST) {
+ if (UNEXPECTED(Z_OPT_COPYABLE_P(arg))) {
+ zval_copy_ctor_func(arg);
+ }
+ }
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_SEND_VAL_EX_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zval *value, *arg;
+ zend_free_op free_op1;
+
+ SAVE_OPLINE();
+ if (ARG_MUST_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
+ zend_error_noreturn(E_ERROR, "Cannot pass parameter %d by reference", opline->op2.num);
+ }
+ value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+ arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
+ ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
+ ZVAL_COPY_VALUE(arg, value);
+ if (IS_TMP_VAR == IS_CONST) {
+ if (UNEXPECTED(Z_OPT_COPYABLE_P(arg))) {
+ zval_copy_ctor_func(arg);
+ }
+ }
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_CLONE_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+ zval *obj;
+ zend_class_entry *ce;
+ zend_function *clone;
+ zend_object_clone_obj_t clone_call;
+
+ SAVE_OPLINE();
+ obj = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+
+ if (IS_TMP_VAR == IS_CONST ||
+ (IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(obj) != IS_OBJECT))) {
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ zend_error_noreturn(E_ERROR, "__clone method called on non-object");
+ }
+
+ ce = Z_OBJCE_P(obj);
+ clone = ce ? ce->clone : NULL;
+ clone_call = Z_OBJ_HT_P(obj)->clone_obj;
+ if (UNEXPECTED(clone_call == NULL)) {
+ if (ce) {
+ zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object of class %s", ce->name->val);
+ } else {
+ zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object");
+ }
+ }
+
+ if (ce && clone) {
+ if (clone->op_array.fn_flags & ZEND_ACC_PRIVATE) {
+ /* Ensure that if we're calling a private function, we're allowed to do so.
+ */
+ if (UNEXPECTED(ce != EG(scope))) {
+ zend_error_noreturn(E_ERROR, "Call to private %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
+ }
+ } else if ((clone->common.fn_flags & ZEND_ACC_PROTECTED)) {
+ /* Ensure that if we're calling a protected function, we're allowed to do so.
+ */
+ if (UNEXPECTED(!zend_check_protected(zend_get_function_root_class(clone), EG(scope)))) {
+ zend_error_noreturn(E_ERROR, "Call to protected %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
+ }
+ }
+ }
+
+ if (EXPECTED(EG(exception) == NULL)) {
+ ZVAL_OBJ(EX_VAR(opline->result.var), clone_call(obj TSRMLS_CC));
+ if (!RETURN_VALUE_USED(opline) || UNEXPECTED(EG(exception) != NULL)) {
+ OBJ_RELEASE(Z_OBJ_P(EX_VAR(opline->result.var)));
+ }
+ }
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_CAST_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+ zval *expr;
+ zval *result = EX_VAR(opline->result.var);
+
+ SAVE_OPLINE();
+ expr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+
+ switch (opline->extended_value) {
+ case IS_NULL:
+ /* This code is taken from convert_to_null. However, it does not seems very useful,
+ * because a conversion to null always results in the same value. This could only
+ * be relevant if a cast_object handler for IS_NULL has some kind of side-effect. */
+#if 0
+ if (IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) {
+ ZVAL_DEREF(expr);
+ }
+ if (Z_TYPE_P(expr) == IS_OBJECT && Z_OBJ_HT_P(expr)->cast_object) {
+ if (Z_OBJ_HT_P(expr)->cast_object(expr, result, IS_NULL TSRMLS_CC) == SUCCESS) {
+ break;
+ }
+ }
+#endif
+
+ ZVAL_NULL(result);
+ break;
+ case _IS_BOOL:
+ ZVAL_BOOL(result, zend_is_true(expr TSRMLS_CC));
+ break;
+ case IS_LONG:
+ ZVAL_LONG(result, zval_get_long(expr));
+ break;
+ case IS_DOUBLE:
+ ZVAL_DOUBLE(result, zval_get_double(expr));
+ break;
+ case IS_STRING:
+ ZVAL_STR(result, zval_get_string(expr));
+ break;
+ default:
+ /* If value is already of correct type, return it directly */
+ if (Z_TYPE_P(expr) == opline->extended_value) {
+ ZVAL_COPY_VALUE(result, expr);
+ if (IS_TMP_VAR == IS_CONST) {
+ if (UNEXPECTED(Z_OPT_COPYABLE_P(result))) {
+ zval_copy_ctor_func(result);
+ }
+ } else if (IS_TMP_VAR != IS_TMP_VAR) {
+ if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
+ }
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+
+ if (opline->extended_value == IS_ARRAY) {
+ if (Z_TYPE_P(expr) != IS_OBJECT) {
+ ZVAL_NEW_ARR(result);
+ zend_hash_init(Z_ARRVAL_P(result), 8, NULL, ZVAL_PTR_DTOR, 0);
+ if (Z_TYPE_P(expr) != IS_NULL) {
+ expr = zend_hash_index_add_new(Z_ARRVAL_P(result), 0, expr);
+ if (IS_TMP_VAR == IS_CONST) {
+ if (UNEXPECTED(Z_OPT_COPYABLE_P(expr))) {
+ zval_copy_ctor_func(expr);
+ }
+ } else {
+ if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
+ }
+ }
+ } else {
+ ZVAL_COPY_VALUE(result, expr);
+ Z_ADDREF_P(result);
+ convert_to_array(result);
+ }
+ } else {
+ if (Z_TYPE_P(expr) != IS_ARRAY) {
+ object_init(result);
+ if (Z_TYPE_P(expr) != IS_NULL) {
+ expr = zend_hash_str_add_new(Z_OBJPROP_P(result), "scalar", sizeof("scalar")-1, expr);
+ if (IS_TMP_VAR == IS_CONST) {
+ if (UNEXPECTED(Z_OPT_COPYABLE_P(expr))) {
+ zval_copy_ctor_func(expr);
+ }
+ } else {
+ if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
+ }
+ }
+ } else {
+ ZVAL_COPY_VALUE(result, expr);
+ zval_opt_copy_ctor(result);
+ convert_to_object(result);
+ }
+ }
+ }
+
+ zval_ptr_dtor_nogc(free_op1);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_FE_RESET_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+ zval *array_ptr, *array_ref, iterator, tmp;
+ HashTable *fe_ht;
+ zend_object_iterator *iter = NULL;
+ zend_class_entry *ce = NULL;
+ zend_bool is_empty = 0;
+
+ SAVE_OPLINE();
+
+ if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) &&
+ (opline->extended_value & ZEND_FE_FETCH_BYREF)) {
+ array_ptr = array_ref = NULL;
+ ZVAL_DEREF(array_ptr);
+ if (Z_TYPE_P(array_ptr) == IS_ARRAY) {
+ SEPARATE_ARRAY(array_ptr);
+ if (!Z_ISREF_P(array_ref)) {
+ ZVAL_NEW_REF(array_ref, array_ref);
+ array_ptr = Z_REFVAL_P(array_ref);
+ }
+ if (Z_REFCOUNTED_P(array_ref)) Z_ADDREF_P(array_ref);
+ } else if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
+ ce = Z_OBJCE_P(array_ptr);
+ if (ce->get_iterator == NULL) {
+ Z_ADDREF_P(array_ptr);
+ }
+ array_ref = array_ptr;
+ } else {
+ if (Z_REFCOUNTED_P(array_ref)) Z_ADDREF_P(array_ref);
}
} else {
array_ptr = array_ref = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_TMP_CONST(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
- zval *varname;
- zval *retval;
- zend_string *name;
- HashTable *target_symbol_table;
+ zval *container;
SAVE_OPLINE();
- varname = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+ container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+ zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
- if (IS_TMP_VAR == IS_CONST) {
- name = Z_STR_P(varname);
- } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
- name = Z_STR_P(varname);
- zend_string_addref(name);
- } else {
- name = zval_get_string(varname);
- }
+ zval_ptr_dtor_nogc(free_op1);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- if (IS_CONST != IS_UNUSED) {
- zend_class_entry *ce;
-
- if (IS_CONST == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- if (IS_TMP_VAR != IS_CONST) {
- zend_string_release(name);
- }
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
- }
- retval = zend_std_get_static_property(ce, name, 0, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
- } else {
- target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- retval = zend_hash_find(target_symbol_table, name);
- if (retval == NULL) {
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_UNSET:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_IS:
- retval = &EG(uninitialized_zval);
- break;
- case BP_VAR_RW:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_W:
- retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
- }
- /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
- } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
- retval = Z_INDIRECT_P(retval);
- if (Z_TYPE_P(retval) == IS_UNDEF) {
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_UNSET:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_IS:
- retval = &EG(uninitialized_zval);
- break;
- case BP_VAR_RW:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_W:
- ZVAL_NULL(retval);
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
- }
- }
- }
- if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
- if (Z_CONSTANT_P(retval)) {
- zval_update_constant(retval, 1 TSRMLS_CC);
- }
- } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
- zval_ptr_dtor_nogc(free_op1);
- }
- }
-
- if (IS_TMP_VAR != IS_CONST) {
- zend_string_release(name);
- }
-
- ZEND_ASSERT(retval != NULL);
- if (type == BP_VAR_R || type == BP_VAR_IS) {
- if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
- ZVAL_UNREF(retval);
- }
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- } else {
- ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_R_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_TMP_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_W_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_TMP_CONST(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_RW_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_TMP_CONST(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_FUNC_ARG_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- return zend_fetch_var_address_helper_SPEC_TMP_CONST(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else {
- return zend_fetch_var_address_helper_SPEC_TMP_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_UNSET_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_TMP_CONST(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_IS_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_TMP_CONST(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *container;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
-
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_DIM_IS_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *container;
+static int ZEND_FASTCALL ZEND_FETCH_DIM_IS_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+ zval *container;
SAVE_OPLINE();
container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_CASE_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *result = EX_VAR(opline->result.var);
-
- SAVE_OPLINE();
- fast_equal_function(result,
- _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- opline->op2.zv TSRMLS_CC);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
}
}
-static int ZEND_FASTCALL ZEND_UNSET_VAR_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval tmp, *varname;
- HashTable *target_symbol_table;
- zend_free_op free_op1;
-
- SAVE_OPLINE();
- if (IS_TMP_VAR == IS_CV &&
- IS_CONST == IS_UNUSED &&
- (opline->extended_value & ZEND_QUICK_SET)) {
- zval *var = EX_VAR(opline->op1.var);
-
- if (Z_REFCOUNTED_P(var)) {
- zend_refcounted *garbage = Z_COUNTED_P(var);
-
- if (!--GC_REFCOUNT(garbage)) {
- ZVAL_UNDEF(var);
- _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
- } else {
- GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
- ZVAL_UNDEF(var);
- }
- } else {
- ZVAL_UNDEF(var);
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-
- varname = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
- ZVAL_UNDEF(&tmp);
- if (IS_TMP_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
- ZVAL_STR(&tmp, zval_get_string(varname));
- varname = &tmp;
- }
-
- if (IS_CONST != IS_UNUSED) {
- zend_class_entry *ce;
-
- if (IS_CONST == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(EG(exception) != NULL)) {
- if (IS_TMP_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
- }
- zval_ptr_dtor_nogc(free_op1);
- HANDLE_EXCEPTION();
- }
- if (UNEXPECTED(ce == NULL)) {
- zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
- }
- zend_std_unset_static_property(ce, Z_STR_P(varname), ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
- } else {
- target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
- }
-
- if (IS_TMP_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
- }
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_VAR_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *value;
-
- SAVE_OPLINE();
- if (IS_TMP_VAR == IS_CV &&
- IS_CONST == IS_UNUSED &&
- (opline->extended_value & ZEND_QUICK_SET)) {
- value = EX_VAR(opline->op1.var);
- if (opline->extended_value & ZEND_ISSET) {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- !i_zend_is_true(value TSRMLS_CC));
- CHECK_EXCEPTION();
- }
- ZEND_VM_NEXT_OPCODE();
- } else {
- zend_free_op free_op1;
- zval tmp, *varname = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
- ZVAL_UNDEF(&tmp);
- if (IS_TMP_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
- ZVAL_STR(&tmp, zval_get_string(varname));
- varname = &tmp;
- }
-
- if (IS_CONST != IS_UNUSED) {
- zend_class_entry *ce;
-
- if (IS_CONST == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
- }
- value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
- } else {
- HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
- }
-
- if (IS_TMP_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
- }
- zval_ptr_dtor_nogc(free_op1);
-
- if (opline->extended_value & ZEND_ISSET) {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- value && Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- !value || !i_zend_is_true(value TSRMLS_CC));
- }
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-}
-
static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
result = 0;
if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
- if (IS_CONST == IS_CV || IS_CONST == IS_VAR) {
+ if (IS_CONST & (IS_CV|IS_VAR)) {
ZVAL_DEREF(offset);
}
if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_YIELD_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *container;
- zend_free_op free_op2;
- zval *offset;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- if ((IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
- UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
- zend_error(E_NOTICE, "Trying to get property of non-object");
- ZVAL_NULL(EX_VAR(opline->result.var));
- } else {
- zval *retval;
+ /* The generator object is stored in EX(return_value) */
+ zend_generator *generator = (zend_generator *) EX(return_value);
- /* here we are sure we are dealing with an object */
- do {
- if (IS_TMP_VAR == IS_CONST &&
- EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
- zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
- zend_object *zobj = Z_OBJ_P(container);
+ if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
+ zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
+ }
- if (EXPECTED(prop_info)) {
- retval = OBJ_PROP(zobj, prop_info->offset);
- if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- } else if (EXPECTED(zobj->properties != NULL)) {
- retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
- if (EXPECTED(retval)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- }
- }
+ /* Destroy the previously yielded value */
+ zval_ptr_dtor(&generator->value);
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+ /* Destroy the previously yielded key */
+ zval_ptr_dtor(&generator->key);
- if (retval != EX_VAR(opline->result.var)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- }
- } while (0);
- }
+ /* Set the new yielded value */
+ if (IS_TMP_VAR != IS_UNUSED) {
+ zend_free_op free_op1;
- zval_ptr_dtor_nogc(free_op2);
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
+ /* Constants and temporary variables aren't yieldable by reference,
+ * but we still allow them with a notice. */
+ if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
+ zval *value;
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *container;
- zend_free_op free_op2;
- zval *offset;
+ zend_error(E_NOTICE, "Only variable references should be yielded by reference");
- SAVE_OPLINE();
- container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+ ZVAL_COPY_VALUE(&generator->value, value);
+ if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
- if ((IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
- UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- } else {
- zval *retval;
+ /* Temporary variables don't need ctor copying */
+ if (IS_TMP_VAR != IS_TMP_VAR) {
+ zval_opt_copy_ctor(&generator->value);
+ }
+ } else {
+ zval *value_ptr = NULL;
- /* here we are sure we are dealing with an object */
- do {
- if (IS_TMP_VAR == IS_CONST &&
- EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
- zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
- zend_object *zobj = Z_OBJ_P(container);
+ if (IS_TMP_VAR == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
+ }
- if (EXPECTED(prop_info)) {
- retval = OBJ_PROP(zobj, prop_info->offset);
- if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- } else if (EXPECTED(zobj->properties != NULL)) {
- retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
- if (EXPECTED(retval)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
+ /* If a function call result is yielded and the function did
+ * not return by reference we throw a notice. */
+ if (IS_TMP_VAR == IS_VAR &&
+ (value_ptr == &EG(uninitialized_zval) ||
+ (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+ !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+ zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+ } else {
+ ZVAL_MAKE_REF(value_ptr);
}
+ ZVAL_COPY(&generator->value, value_ptr);
+
}
+ } else {
+ zval *value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+ /* Consts, temporary variables and references need copying */
+ if (IS_TMP_VAR == IS_CONST) {
+ ZVAL_DUP(&generator->value, value);
+ } else if (IS_TMP_VAR == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&generator->value, value);
+ } else if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) && Z_ISREF_P(value)) {
+ ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
- if (retval != EX_VAR(opline->result.var)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ } else {
+ ZVAL_COPY_VALUE(&generator->value, value);
+ if (IS_TMP_VAR == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+ }
}
- } while (0);
+ }
+ } else {
+ /* If no value was specified yield null */
+ ZVAL_NULL(&generator->value);
}
- zval_ptr_dtor_nogc(free_op2);
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *container;
-
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- /* Behave like FETCH_OBJ_W */
- zend_free_op free_op1, free_op2;
- zval *property;
+ /* Set the new yielded key */
+ if (IS_TMP_VAR != IS_UNUSED) {
+ zend_free_op free_op2;
+ zval *key = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- SAVE_OPLINE();
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- container = NULL;
+ /* Consts, temporary variables and references need copying */
+ if (IS_TMP_VAR == IS_CONST) {
+ ZVAL_DUP(&generator->key, key);
+ } else if (IS_TMP_VAR == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&generator->key, key);
+ } else if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && Z_ISREF_P(key)) {
+ ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
- if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
- zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
- }
- if (IS_TMP_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+ } else {
+ ZVAL_COPY_VALUE(&generator->key, key);
+ if (IS_TMP_VAR == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
+ }
}
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_TMP_VAR, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- if (IS_TMP_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+
+ if (Z_TYPE(generator->key) == IS_LONG
+ && Z_LVAL(generator->key) > generator->largest_used_integer_key
+ ) {
+ generator->largest_used_integer_key = Z_LVAL(generator->key);
}
+ } else {
+ /* If no key was specified we use auto-increment keys */
+ generator->largest_used_integer_key++;
+ ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
+ }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (RETURN_VALUE_USED(opline)) {
+ /* If the return value of yield is used set the send
+ * target and initialize it to NULL */
+ generator->send_target = EX_VAR(opline->result.var);
+ ZVAL_NULL(generator->send_target);
} else {
- return ZEND_FETCH_OBJ_R_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ generator->send_target = NULL;
}
-}
-static int ZEND_FASTCALL ZEND_ADD_VAR_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
- zval *str = EX_VAR(opline->result.var);
- zval *var;
- zval var_copy;
- int use_copy = 0;
+ /* We increment to the next op, so we are at the correct position when the
+ * generator is resumed. */
+ ZEND_VM_INC_OPCODE();
+ /* The GOTO VM uses a local opline variable. We need to set the opline
+ * variable in execute_data so we don't resume at an old position. */
SAVE_OPLINE();
- var = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-
- if (IS_TMP_VAR == IS_UNUSED) {
- /* Initialize for erealloc in add_string_to_string */
- ZVAL_EMPTY_STRING(str);
- }
- if (Z_TYPE_P(var) != IS_STRING) {
- if (IS_TMP_VAR != IS_TMP_VAR) {
- ZVAL_DEREF(var);
- }
- if (Z_TYPE_P(var) != IS_STRING) {
- use_copy = zend_make_printable_zval(var, &var_copy TSRMLS_CC);
+ ZEND_VM_RETURN();
+}
- if (use_copy) {
- var = &var_copy;
- }
- }
- }
- add_string_to_string(str, str, var);
+static int ZEND_FASTCALL ZEND_POW_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1, free_op2;
- if (use_copy) {
- zend_string_release(Z_STR_P(var));
- }
- /* original comment, possibly problematic:
- * FREE_OP is missing intentionally here - we're always working on the same temporary variable
- * (Zeev): I don't think it's problematic, we only use variables
- * which aren't affected by FREE_OP(Ts, )'s anyway, unless they're
- * string offsets or overloaded objects
- */
+ SAVE_OPLINE();
+ pow_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
zval_ptr_dtor_nogc(free_op2);
-
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_MOD_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *function_name;
zend_free_op free_op1, free_op2;
- zval *object;
- zend_function *fbc;
- zend_class_entry *called_scope;
- zend_object *obj;
SAVE_OPLINE();
+ fast_mod_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
+ zval_ptr_dtor_nogc(free_op2);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- function_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+static int ZEND_FASTCALL ZEND_SL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1, free_op2;
- if (IS_TMP_VAR != IS_CONST &&
- UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- zend_error_noreturn(E_ERROR, "Method name must be a string");
- }
-
- object = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
- if (IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- uint32_t nesting = 1;
-
- if (UNEXPECTED(EG(exception) != NULL)) {
- zval_ptr_dtor_nogc(free_op2);
- HANDLE_EXCEPTION();
- }
-
- zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s", Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
- zval_ptr_dtor_nogc(free_op2);
-
- if (EG(exception) != NULL) {
- HANDLE_EXCEPTION();
- }
-
- /* No exception raised: Skip over arguments until fcall opcode with correct
- * nesting level. Return NULL (except when return value unused) */
- do {
- opline++;
- if (opline->opcode == ZEND_INIT_FCALL ||
- opline->opcode == ZEND_INIT_FCALL_BY_NAME ||
- opline->opcode == ZEND_INIT_NS_FCALL_BY_NAME ||
- opline->opcode == ZEND_INIT_METHOD_CALL ||
- opline->opcode == ZEND_INIT_STATIC_METHOD_CALL ||
- opline->opcode == ZEND_INIT_USER_CALL ||
- opline->opcode == ZEND_NEW
- ) {
- nesting++;
- } else if (opline->opcode == ZEND_DO_FCALL) {
- nesting--;
- }
- } while (nesting);
-
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
-
- /* We've skipped EXT_FCALL_BEGIND, so also skip the ending opcode */
- if ((opline + 1)->opcode == ZEND_EXT_FCALL_END) {
- opline++;
- }
- ZEND_VM_JMP(++opline);
- }
-
- obj = Z_OBJ_P(object);
- called_scope = obj->ce;
+ SAVE_OPLINE();
+ shift_left_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
+ zval_ptr_dtor_nogc(free_op2);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- if (IS_TMP_VAR != IS_CONST ||
- EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
- zend_object *orig_obj = obj;
+static int ZEND_FASTCALL ZEND_SR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1, free_op2;
- if (UNEXPECTED(obj->handlers->get_method == NULL)) {
- zend_error_noreturn(E_ERROR, "Object does not support method calls");
- }
+ SAVE_OPLINE();
+ shift_right_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
+ zval_ptr_dtor_nogc(free_op2);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- /* First, locate the function. */
- fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_TMP_VAR == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
- if (UNEXPECTED(fbc == NULL)) {
- zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
- }
- if (IS_TMP_VAR == IS_CONST &&
- EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
- EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
- EXPECTED(obj == orig_obj)) {
- CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope, fbc);
- }
- }
+static int ZEND_FASTCALL ZEND_CONCAT_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1, free_op2;
- if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_STATIC) != 0)) {
- obj = NULL;
- } else {
- GC_REFCOUNT(obj)++; /* For $this pointer */
- }
+ SAVE_OPLINE();
+ concat_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
+ zval_ptr_dtor_nogc(free_op2);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
- fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
+static int ZEND_FASTCALL ZEND_IS_IDENTICAL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1, free_op2;
+ SAVE_OPLINE();
+ fast_is_identical_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
zval_ptr_dtor_nogc(free_op2);
-
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_CASE_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_IS_NOT_IDENTICAL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
zval *result = EX_VAR(opline->result.var);
SAVE_OPLINE();
- fast_equal_function(result,
- _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
-
+ fast_is_not_identical_function(result,
+ _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BW_OR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *expr_ptr, new_expr;
+ zend_free_op free_op1, free_op2;
SAVE_OPLINE();
- if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) &&
- (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
- expr_ptr = NULL;
- if (IS_TMP_VAR == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
- }
- ZVAL_MAKE_REF(expr_ptr);
- Z_ADDREF_P(expr_ptr);
+ bitwise_or_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
+ zval_ptr_dtor_nogc(free_op2);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- } else {
- expr_ptr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- if (IS_TMP_VAR == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&new_expr, expr_ptr);
- expr_ptr = &new_expr;
- } else if (IS_TMP_VAR == IS_CONST) {
- if (!Z_IMMUTABLE_P(expr_ptr)) {
- ZVAL_DUP(&new_expr, expr_ptr);
- expr_ptr = &new_expr;
- }
- } else if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) && Z_ISREF_P(expr_ptr)) {
- expr_ptr = Z_REFVAL_P(expr_ptr);
- if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
+static int ZEND_FASTCALL ZEND_BW_AND_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1, free_op2;
- } else if (IS_TMP_VAR == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
- Z_ADDREF_P(expr_ptr);
- }
- }
+ SAVE_OPLINE();
+ bitwise_and_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
+ zval_ptr_dtor_nogc(free_op2);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- if (IS_TMP_VAR != IS_UNUSED) {
- zend_free_op free_op2;
- zval *offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- zend_string *str;
- zend_ulong hval;
+static int ZEND_FASTCALL ZEND_BW_XOR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1, free_op2;
-add_again:
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- goto num_index;
- case IS_LONG:
- hval = Z_LVAL_P(offset);
-num_index:
- zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
- break;
- case IS_STRING:
- str = Z_STR_P(offset);
- if (IS_TMP_VAR != IS_CONST) {
- if (ZEND_HANDLE_NUMERIC(str, hval)) {
- goto num_index;
- }
- }
-str_index:
- zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
- break;
- case IS_NULL:
- str = STR_EMPTY_ALLOC();
- goto str_index;
- case IS_FALSE:
- hval = 0;
- goto num_index;
- case IS_TRUE:
- hval = 1;
- goto num_index;
- case IS_REFERENCE:
- offset = Z_REFVAL_P(offset);
- goto add_again;
- break;
- default:
- zend_error(E_WARNING, "Illegal offset type");
- zval_ptr_dtor(expr_ptr);
- /* do nothing */
- break;
- }
- zval_ptr_dtor_nogc(free_op2);
- } else {
- zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
- }
+ SAVE_OPLINE();
+ bitwise_xor_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
+ zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BOOL_XOR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- zval *array;
- uint32_t size;
USE_OPLINE
+ zend_free_op free_op1, free_op2;
- array = EX_VAR(opline->result.var);
- if (IS_TMP_VAR != IS_UNUSED) {
- size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
- } else {
- size = 0;
- }
- ZVAL_NEW_ARR(array);
- zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
+ SAVE_OPLINE();
+ boolean_xor_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
+ zval_ptr_dtor_nogc(free_op2);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- if (IS_TMP_VAR != IS_UNUSED) {
- /* Explicitly initialize array as not-packed if flag is set */
- if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
- zend_hash_real_init(Z_ARRVAL_P(array), 0);
- }
- }
+static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1, free_op2;
+ zval *container;
- if (IS_TMP_VAR == IS_UNUSED) {
- ZEND_VM_NEXT_OPCODE();
-#if 0 || IS_TMP_VAR != IS_UNUSED
- } else {
- return ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-#endif
- }
+ SAVE_OPLINE();
+ container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+ zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ zval_ptr_dtor_nogc(free_op1);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_IS_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
zval *container;
- int result;
- zend_ulong hval;
- zval *offset;
SAVE_OPLINE();
container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ zval_ptr_dtor_nogc(free_op1);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- if (IS_TMP_VAR != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
- HashTable *ht = Z_ARRVAL_P(container);
- zval *value;
- zend_string *str;
+static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zval *container;
+ zend_free_op free_op1, free_op2;
-isset_again:
- if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
- str = Z_STR_P(offset);
- if (IS_TMP_VAR != IS_CONST) {
- if (ZEND_HANDLE_NUMERIC(str, hval)) {
- goto num_index_prop;
- }
- }
-str_index_prop:
- value = zend_hash_find_ind(ht, str);
- } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
- hval = Z_LVAL_P(offset);
-num_index_prop:
- value = zend_hash_index_find(ht, hval);
- } else {
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- goto num_index_prop;
- case IS_NULL:
- str = STR_EMPTY_ALLOC();
- goto str_index_prop;
- case IS_FALSE:
- hval = 0;
- goto num_index_prop;
- case IS_TRUE:
- hval = 1;
- goto num_index_prop;
- case IS_RESOURCE:
- hval = Z_RES_HANDLE_P(offset);
- goto num_index_prop;
- case IS_REFERENCE:
- offset = Z_REFVAL_P(offset);
- goto isset_again;
- default:
- zend_error(E_WARNING, "Illegal offset type in isset or empty");
- value = NULL;
- break;
- }
- }
+ SAVE_OPLINE();
- if (opline->extended_value & ZEND_ISSET) {
- /* > IS_NULL means not IS_UNDEF and not IS_NULL */
- result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
- }
- } else if (IS_TMP_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
- result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to check element of non-array");
- result = 0;
+ if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+ if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
+ zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+ }
+ container = NULL;
+ if (IS_TMP_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+ if (IS_TMP_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
- } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
- zval tmp;
+ zval_ptr_dtor_nogc(free_op2);
- result = 0;
- if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
- if (IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) {
- ZVAL_DEREF(offset);
- }
- if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
- || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
- && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
- ZVAL_DUP(&tmp, offset);
- convert_to_long(&tmp);
- offset = &tmp;
- }
- }
- if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
- if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
- if ((opline->extended_value & ZEND_ISSET) ||
- Z_STRVAL_P(container)[offset->value.lval] != '0') {
- result = 1;
- }
- }
- }
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
- }
} else {
- result = ((opline->extended_value & ZEND_ISSET) == 0);
+ if (IS_VAR == IS_UNUSED) {
+ zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
+ }
+ container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+ zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ zval_ptr_dtor_nogc(free_op1);
}
-
- zval_ptr_dtor_nogc(free_op2);
- ZVAL_BOOL(EX_VAR(opline->result.var), result);
- zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INSTANCEOF_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *container;
- int result;
- zval *offset;
+ zend_free_op free_op1;
+ zval *expr;
+ zend_bool result;
SAVE_OPLINE();
- container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ expr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- if (IS_TMP_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
- result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+ if (Z_TYPE_P(expr) == IS_OBJECT) {
+ zend_class_entry *ce;
+
+ if (IS_VAR == IS_CONST) {
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ } else {
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, ZEND_FETCH_CLASS_NO_AUTOLOAD TSRMLS_CC);
+ if (UNEXPECTED(ce == NULL)) {
+ ZVAL_FALSE(EX_VAR(opline->result.var));
+ zval_ptr_dtor_nogc(free_op1);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+ }
} else {
- zend_error(E_NOTICE, "Trying to check property of non-object");
- result = 0;
- }
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
+ ce = Z_CE_P(EX_VAR(opline->op2.var));
}
+ result = instanceof_function(Z_OBJCE_P(expr), ce TSRMLS_CC);
} else {
- result = ((opline->extended_value & ZEND_ISSET) == 0);
+ result = 0;
}
-
- zval_ptr_dtor_nogc(free_op2);
ZVAL_BOOL(EX_VAR(opline->result.var), result);
zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_YIELD_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_YIELD_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
}
/* Set the new yielded key */
- if (IS_TMP_VAR != IS_UNUSED) {
+ if (IS_VAR != IS_UNUSED) {
zend_free_op free_op2;
- zval *key = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ zval *key = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
/* Consts, temporary variables and references need copying */
- if (IS_TMP_VAR == IS_CONST) {
+ if (IS_VAR == IS_CONST) {
ZVAL_DUP(&generator->key, key);
- } else if (IS_TMP_VAR == IS_TMP_VAR) {
+ } else if (IS_VAR == IS_TMP_VAR) {
ZVAL_COPY_VALUE(&generator->key, key);
- } else if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && Z_ISREF_P(key)) {
+ } else if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && Z_ISREF_P(key)) {
ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
-
+ zval_ptr_dtor_nogc(free_op2);
} else {
ZVAL_COPY_VALUE(&generator->key, key);
- if (IS_TMP_VAR == IS_CV) {
+ if (IS_VAR == IS_CV) {
if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
}
}
ZEND_VM_RETURN();
}
-static int ZEND_FASTCALL ZEND_POW_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_POW_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
SAVE_OPLINE();
pow_function(EX_VAR(opline->result.var),
_get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_MOD_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zval *container;
+ zend_free_op free_op1;
SAVE_OPLINE();
- fast_mod_function(EX_VAR(opline->result.var),
- _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
- zval_ptr_dtor_nogc(free_op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-static int ZEND_FASTCALL ZEND_SL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1, free_op2;
+ if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+ if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
+ zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+ }
+ container = NULL;
+ if (IS_TMP_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ }
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
+ if (IS_TMP_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ }
- SAVE_OPLINE();
- shift_left_function(EX_VAR(opline->result.var),
- _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
- zval_ptr_dtor_nogc(free_op2);
+
+ } else {
+ if (IS_UNUSED == IS_UNUSED) {
+ zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
+ }
+ container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+ zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
+
+ zval_ptr_dtor_nogc(free_op1);
+ }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_SR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
+ zval *expr_ptr, new_expr;
SAVE_OPLINE();
- shift_right_function(EX_VAR(opline->result.var),
- _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
- zval_ptr_dtor_nogc(free_op2);
+ if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) &&
+ (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
+ expr_ptr = NULL;
+ if (IS_TMP_VAR == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
+ }
+ ZVAL_MAKE_REF(expr_ptr);
+ Z_ADDREF_P(expr_ptr);
+
+ } else {
+ expr_ptr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+ if (IS_TMP_VAR == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&new_expr, expr_ptr);
+ expr_ptr = &new_expr;
+ } else if (IS_TMP_VAR == IS_CONST) {
+ if (!Z_IMMUTABLE_P(expr_ptr)) {
+ ZVAL_DUP(&new_expr, expr_ptr);
+ expr_ptr = &new_expr;
+ }
+ } else if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) && Z_ISREF_P(expr_ptr)) {
+ expr_ptr = Z_REFVAL_P(expr_ptr);
+ if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
+
+ } else if (IS_TMP_VAR == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
+ Z_ADDREF_P(expr_ptr);
+ }
+ }
+
+ if (IS_UNUSED != IS_UNUSED) {
+
+ zval *offset = NULL;
+ zend_string *str;
+ zend_ulong hval;
+
+add_again:
+ switch (Z_TYPE_P(offset)) {
+ case IS_DOUBLE:
+ hval = zend_dval_to_lval(Z_DVAL_P(offset));
+ goto num_index;
+ case IS_LONG:
+ hval = Z_LVAL_P(offset);
+num_index:
+ zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
+ break;
+ case IS_STRING:
+ str = Z_STR_P(offset);
+ if (IS_UNUSED != IS_CONST) {
+ if (ZEND_HANDLE_NUMERIC(str, hval)) {
+ goto num_index;
+ }
+ }
+str_index:
+ zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
+ break;
+ case IS_NULL:
+ str = STR_EMPTY_ALLOC();
+ goto str_index;
+ case IS_FALSE:
+ hval = 0;
+ goto num_index;
+ case IS_TRUE:
+ hval = 1;
+ goto num_index;
+ case IS_REFERENCE:
+ offset = Z_REFVAL_P(offset);
+ goto add_again;
+ break;
+ default:
+ zend_error(E_WARNING, "Illegal offset type");
+ zval_ptr_dtor(expr_ptr);
+ /* do nothing */
+ break;
+ }
+
+ } else {
+ zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
+ }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_CONCAT_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+ zval *array;
+ uint32_t size;
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ array = EX_VAR(opline->result.var);
+ if (IS_TMP_VAR != IS_UNUSED) {
+ size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
+ } else {
+ size = 0;
+ }
+ ZVAL_NEW_ARR(array);
+ zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
+
+ if (IS_TMP_VAR != IS_UNUSED) {
+ /* Explicitly initialize array as not-packed if flag is set */
+ if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
+ zend_hash_real_init(Z_ARRVAL_P(array), 0);
+ }
+ }
+
+ if (IS_TMP_VAR == IS_UNUSED) {
+ ZEND_VM_NEXT_OPCODE();
+#if 0 || IS_TMP_VAR != IS_UNUSED
+ } else {
+ return ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+#endif
+ }
+}
+
+static int ZEND_FASTCALL ZEND_YIELD_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ /* The generator object is stored in EX(return_value) */
+ zend_generator *generator = (zend_generator *) EX(return_value);
+
+ if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
+ zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
+ }
+
+ /* Destroy the previously yielded value */
+ zval_ptr_dtor(&generator->value);
+
+ /* Destroy the previously yielded key */
+ zval_ptr_dtor(&generator->key);
+
+ /* Set the new yielded value */
+ if (IS_TMP_VAR != IS_UNUSED) {
+ zend_free_op free_op1;
+
+ if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
+ /* Constants and temporary variables aren't yieldable by reference,
+ * but we still allow them with a notice. */
+ if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
+ zval *value;
+
+ zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+
+ value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+ ZVAL_COPY_VALUE(&generator->value, value);
+ if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
+
+ /* Temporary variables don't need ctor copying */
+ if (IS_TMP_VAR != IS_TMP_VAR) {
+ zval_opt_copy_ctor(&generator->value);
+ }
+ } else {
+ zval *value_ptr = NULL;
+
+ if (IS_TMP_VAR == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
+ }
+
+ /* If a function call result is yielded and the function did
+ * not return by reference we throw a notice. */
+ if (IS_TMP_VAR == IS_VAR &&
+ (value_ptr == &EG(uninitialized_zval) ||
+ (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+ !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+ zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+ } else {
+ ZVAL_MAKE_REF(value_ptr);
+ }
+ ZVAL_COPY(&generator->value, value_ptr);
+
+ }
+ } else {
+ zval *value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+
+ /* Consts, temporary variables and references need copying */
+ if (IS_TMP_VAR == IS_CONST) {
+ ZVAL_DUP(&generator->value, value);
+ } else if (IS_TMP_VAR == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&generator->value, value);
+ } else if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) && Z_ISREF_P(value)) {
+ ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
+
+ } else {
+ ZVAL_COPY_VALUE(&generator->value, value);
+ if (IS_TMP_VAR == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+ }
+ }
+ }
+ } else {
+ /* If no value was specified yield null */
+ ZVAL_NULL(&generator->value);
+ }
+
+ /* Set the new yielded key */
+ if (IS_UNUSED != IS_UNUSED) {
+
+ zval *key = NULL;
+
+ /* Consts, temporary variables and references need copying */
+ if (IS_UNUSED == IS_CONST) {
+ ZVAL_DUP(&generator->key, key);
+ } else if (IS_UNUSED == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&generator->key, key);
+ } else if ((IS_UNUSED == IS_VAR || IS_UNUSED == IS_CV) && Z_ISREF_P(key)) {
+ ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
+
+ } else {
+ ZVAL_COPY_VALUE(&generator->key, key);
+ if (IS_UNUSED == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
+ }
+ }
+
+ if (Z_TYPE(generator->key) == IS_LONG
+ && Z_LVAL(generator->key) > generator->largest_used_integer_key
+ ) {
+ generator->largest_used_integer_key = Z_LVAL(generator->key);
+ }
+ } else {
+ /* If no key was specified we use auto-increment keys */
+ generator->largest_used_integer_key++;
+ ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
+ }
+
+ if (RETURN_VALUE_USED(opline)) {
+ /* If the return value of yield is used set the send
+ * target and initialize it to NULL */
+ generator->send_target = EX_VAR(opline->result.var);
+ ZVAL_NULL(generator->send_target);
+ } else {
+ generator->send_target = NULL;
+ }
+
+ /* We increment to the next op, so we are at the correct position when the
+ * generator is resumed. */
+ ZEND_VM_INC_OPCODE();
+
+ /* The GOTO VM uses a local opline variable. We need to set the opline
+ * variable in execute_data so we don't resume at an old position. */
SAVE_OPLINE();
- concat_function(EX_VAR(opline->result.var),
+
+ ZEND_VM_RETURN();
+}
+
+static int ZEND_FASTCALL ZEND_MOD_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+
+ SAVE_OPLINE();
+ fast_mod_function(EX_VAR(opline->result.var),
_get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
- zval_ptr_dtor_nogc(free_op2);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_IS_IDENTICAL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SL_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
SAVE_OPLINE();
- fast_is_identical_function(EX_VAR(opline->result.var),
+ shift_left_function(EX_VAR(opline->result.var),
_get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
- zval_ptr_dtor_nogc(free_op2);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_IS_NOT_IDENTICAL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *result = EX_VAR(opline->result.var);
+ zend_free_op free_op1;
SAVE_OPLINE();
- fast_is_not_identical_function(result,
+ shift_right_function(EX_VAR(opline->result.var),
_get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
- zval_ptr_dtor_nogc(free_op2);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_BW_OR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_CONCAT_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
SAVE_OPLINE();
- bitwise_or_function(EX_VAR(opline->result.var),
+ concat_function(EX_VAR(opline->result.var),
_get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
- zval_ptr_dtor_nogc(free_op2);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_BW_AND_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_IS_IDENTICAL_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
SAVE_OPLINE();
- bitwise_and_function(EX_VAR(opline->result.var),
+ fast_is_identical_function(EX_VAR(opline->result.var),
_get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
- zval_ptr_dtor_nogc(free_op2);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_BW_XOR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_IS_NOT_IDENTICAL_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
+ zval *result = EX_VAR(opline->result.var);
SAVE_OPLINE();
- bitwise_xor_function(EX_VAR(opline->result.var),
+ fast_is_not_identical_function(result,
_get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
- zval_ptr_dtor_nogc(free_op2);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_BOOL_XOR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BW_OR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
SAVE_OPLINE();
- boolean_xor_function(EX_VAR(opline->result.var),
+ bitwise_or_function(EX_VAR(opline->result.var),
_get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
- zval_ptr_dtor_nogc(free_op2);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_TMP_VAR(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BW_AND_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
- zval *varname;
- zval *retval;
- zend_string *name;
- HashTable *target_symbol_table;
SAVE_OPLINE();
- varname = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
- if (IS_TMP_VAR == IS_CONST) {
- name = Z_STR_P(varname);
- } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
- name = Z_STR_P(varname);
- zend_string_addref(name);
- } else {
- name = zval_get_string(varname);
- }
-
- if (IS_VAR != IS_UNUSED) {
- zend_class_entry *ce;
-
- if (IS_VAR == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- if (IS_TMP_VAR != IS_CONST) {
- zend_string_release(name);
- }
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
- }
- retval = zend_std_get_static_property(ce, name, 0, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
- } else {
- target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- retval = zend_hash_find(target_symbol_table, name);
- if (retval == NULL) {
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_UNSET:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_IS:
- retval = &EG(uninitialized_zval);
- break;
- case BP_VAR_RW:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_W:
- retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
- }
- /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
- } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
- retval = Z_INDIRECT_P(retval);
- if (Z_TYPE_P(retval) == IS_UNDEF) {
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_UNSET:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_IS:
- retval = &EG(uninitialized_zval);
- break;
- case BP_VAR_RW:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_W:
- ZVAL_NULL(retval);
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
- }
- }
- }
- if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
- if (Z_CONSTANT_P(retval)) {
- zval_update_constant(retval, 1 TSRMLS_CC);
- }
- } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
- zval_ptr_dtor_nogc(free_op1);
- }
- }
-
- if (IS_TMP_VAR != IS_CONST) {
- zend_string_release(name);
- }
+ bitwise_and_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
- ZEND_ASSERT(retval != NULL);
- if (type == BP_VAR_R || type == BP_VAR_IS) {
- if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
- ZVAL_UNREF(retval);
- }
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- } else {
- ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
- }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_R_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BW_XOR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_fetch_var_address_helper_SPEC_TMP_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ USE_OPLINE
+ zend_free_op free_op1;
-static int ZEND_FASTCALL ZEND_FETCH_W_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_TMP_VAR(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ SAVE_OPLINE();
+ bitwise_xor_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
-static int ZEND_FASTCALL ZEND_FETCH_RW_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_TMP_VAR(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_FUNC_ARG_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BOOL_XOR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zend_free_op free_op1;
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- return zend_fetch_var_address_helper_SPEC_TMP_VAR(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else {
- return zend_fetch_var_address_helper_SPEC_TMP_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_UNSET_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_TMP_VAR(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ SAVE_OPLINE();
+ boolean_xor_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
-static int ZEND_FASTCALL ZEND_FETCH_IS_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_TMP_VAR(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *container;
SAVE_OPLINE();
container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
+
zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_IS_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_IS_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *container;
SAVE_OPLINE();
container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
+
zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *container;
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
SAVE_OPLINE();
zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
ZVAL_DEREF(container);
- zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+ zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
if (IS_TMP_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
- zval_ptr_dtor_nogc(free_op2);
+
} else {
- if (IS_VAR == IS_UNUSED) {
+ if (IS_CV == IS_UNUSED) {
zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
}
container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
+
zval_ptr_dtor_nogc(free_op1);
}
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
zval *container;
- zend_free_op free_op2;
+
zval *offset;
SAVE_OPLINE();
container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
if ((IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
/* here we are sure we are dealing with an object */
do {
- if (IS_VAR == IS_CONST &&
+ if (IS_CV == IS_CONST &&
EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
zend_object *zobj = Z_OBJ_P(container);
}
}
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+ retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
if (retval != EX_VAR(opline->result.var)) {
ZVAL_COPY(EX_VAR(opline->result.var), retval);
} while (0);
}
- zval_ptr_dtor_nogc(free_op2);
zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
zval *container;
- zend_free_op free_op2;
+
zval *offset;
SAVE_OPLINE();
container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
if ((IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
/* here we are sure we are dealing with an object */
do {
- if (IS_VAR == IS_CONST &&
+ if (IS_CV == IS_CONST &&
EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
zend_object *zobj = Z_OBJ_P(container);
}
}
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+ retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
if (retval != EX_VAR(opline->result.var)) {
ZVAL_COPY(EX_VAR(opline->result.var), retval);
} while (0);
}
- zval_ptr_dtor_nogc(free_op2);
zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *container;
if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
/* Behave like FETCH_OBJ_W */
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *property;
SAVE_OPLINE();
- property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
container = NULL;
if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
if (IS_TMP_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
}
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_TMP_VAR, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_TMP_VAR, property, IS_CV, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+
if (IS_TMP_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
} else {
- return ZEND_FETCH_OBJ_R_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return ZEND_FETCH_OBJ_R_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ADD_VAR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ADD_VAR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
+
zval *str = EX_VAR(opline->result.var);
zval *var;
zval var_copy;
int use_copy = 0;
SAVE_OPLINE();
- var = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ var = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
if (IS_TMP_VAR == IS_UNUSED) {
/* Initialize for erealloc in add_string_to_string */
}
if (Z_TYPE_P(var) != IS_STRING) {
- if (IS_VAR != IS_TMP_VAR) {
- ZVAL_DEREF(var);
- }
- if (Z_TYPE_P(var) != IS_STRING) {
- use_copy = zend_make_printable_zval(var, &var_copy TSRMLS_CC);
+ use_copy = zend_make_printable_zval(var, &var_copy TSRMLS_CC);
- if (use_copy) {
- var = &var_copy;
- }
+ if (use_copy) {
+ var = &var_copy;
}
}
add_string_to_string(str, str, var);
* which aren't affected by FREE_OP(Ts, )'s anyway, unless they're
* string offsets or overloaded objects
*/
- zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *function_name;
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *object;
zend_function *fbc;
zend_class_entry *called_scope;
SAVE_OPLINE();
- function_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ function_name = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
- if (IS_VAR != IS_CONST &&
+ if (IS_CV != IS_CONST &&
UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
if (UNEXPECTED(EG(exception) != NULL)) {
HANDLE_EXCEPTION();
uint32_t nesting = 1;
if (UNEXPECTED(EG(exception) != NULL)) {
- zval_ptr_dtor_nogc(free_op2);
+
HANDLE_EXCEPTION();
}
zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s", Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
- zval_ptr_dtor_nogc(free_op2);
+
if (EG(exception) != NULL) {
HANDLE_EXCEPTION();
obj = Z_OBJ_P(object);
called_scope = obj->ce;
- if (IS_VAR != IS_CONST ||
+ if (IS_CV != IS_CONST ||
EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
zend_object *orig_obj = obj;
}
/* First, locate the function. */
- fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_VAR == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
+ fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_CV == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
if (UNEXPECTED(fbc == NULL)) {
zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
}
- if (IS_VAR == IS_CONST &&
+ if (IS_CV == IS_CONST &&
EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
EXPECTED(obj == orig_obj)) {
EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_CASE_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *result = EX_VAR(opline->result.var);
-
- SAVE_OPLINE();
- fast_equal_function(result,
- _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
}
}
- if (IS_VAR != IS_UNUSED) {
- zend_free_op free_op2;
- zval *offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ if (IS_CV != IS_UNUSED) {
+
+ zval *offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
zend_string *str;
zend_ulong hval;
break;
case IS_STRING:
str = Z_STR_P(offset);
- if (IS_VAR != IS_CONST) {
+ if (IS_CV != IS_CONST) {
if (ZEND_HANDLE_NUMERIC(str, hval)) {
goto num_index;
}
/* do nothing */
break;
}
- zval_ptr_dtor_nogc(free_op2);
+
} else {
zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
zval *array;
uint32_t size;
ZEND_VM_NEXT_OPCODE();
#if 0 || IS_TMP_VAR != IS_UNUSED
} else {
- return ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
#endif
}
}
-static int ZEND_FASTCALL ZEND_UNSET_VAR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval tmp, *varname;
- HashTable *target_symbol_table;
zend_free_op free_op1;
-
- SAVE_OPLINE();
- if (IS_TMP_VAR == IS_CV &&
- IS_VAR == IS_UNUSED &&
- (opline->extended_value & ZEND_QUICK_SET)) {
- zval *var = EX_VAR(opline->op1.var);
-
- if (Z_REFCOUNTED_P(var)) {
- zend_refcounted *garbage = Z_COUNTED_P(var);
-
- if (!--GC_REFCOUNT(garbage)) {
- ZVAL_UNDEF(var);
- _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
- } else {
- GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
- ZVAL_UNDEF(var);
- }
- } else {
- ZVAL_UNDEF(var);
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-
- varname = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
- ZVAL_UNDEF(&tmp);
- if (IS_TMP_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
- ZVAL_STR(&tmp, zval_get_string(varname));
- varname = &tmp;
- }
-
- if (IS_VAR != IS_UNUSED) {
- zend_class_entry *ce;
-
- if (IS_VAR == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(EG(exception) != NULL)) {
- if (IS_TMP_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
- }
- zval_ptr_dtor_nogc(free_op1);
- HANDLE_EXCEPTION();
- }
- if (UNEXPECTED(ce == NULL)) {
- zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
- }
- zend_std_unset_static_property(ce, Z_STR_P(varname), ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
- } else {
- target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
- }
-
- if (IS_TMP_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
- }
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_VAR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *value;
-
- SAVE_OPLINE();
- if (IS_TMP_VAR == IS_CV &&
- IS_VAR == IS_UNUSED &&
- (opline->extended_value & ZEND_QUICK_SET)) {
- value = EX_VAR(opline->op1.var);
- if (opline->extended_value & ZEND_ISSET) {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- !i_zend_is_true(value TSRMLS_CC));
- CHECK_EXCEPTION();
- }
- ZEND_VM_NEXT_OPCODE();
- } else {
- zend_free_op free_op1;
- zval tmp, *varname = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
- ZVAL_UNDEF(&tmp);
- if (IS_TMP_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
- ZVAL_STR(&tmp, zval_get_string(varname));
- varname = &tmp;
- }
-
- if (IS_VAR != IS_UNUSED) {
- zend_class_entry *ce;
-
- if (IS_VAR == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
- }
- value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
- } else {
- HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
- }
-
- if (IS_TMP_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
- }
- zval_ptr_dtor_nogc(free_op1);
-
- if (opline->extended_value & ZEND_ISSET) {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- value && Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- !value || !i_zend_is_true(value TSRMLS_CC));
- }
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-}
-
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1, free_op2;
zval *container;
int result;
zend_ulong hval;
SAVE_OPLINE();
container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
if (IS_TMP_VAR != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
HashTable *ht = Z_ARRVAL_P(container);
isset_again:
if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
str = Z_STR_P(offset);
- if (IS_VAR != IS_CONST) {
+ if (IS_CV != IS_CONST) {
if (ZEND_HANDLE_NUMERIC(str, hval)) {
goto num_index_prop;
}
result = 0;
if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
- if (IS_VAR == IS_CV || IS_VAR == IS_VAR) {
+ if (IS_CV & (IS_CV|IS_VAR)) {
ZVAL_DEREF(offset);
}
if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
result = ((opline->extended_value & ZEND_ISSET) == 0);
}
- zval_ptr_dtor_nogc(free_op2);
ZVAL_BOOL(EX_VAR(opline->result.var), result);
zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *container;
int result;
zval *offset;
SAVE_OPLINE();
container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
if (IS_TMP_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
- result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+ result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
} else {
zend_error(E_NOTICE, "Trying to check property of non-object");
result = 0;
result = ((opline->extended_value & ZEND_ISSET) == 0);
}
- zval_ptr_dtor_nogc(free_op2);
- ZVAL_BOOL(EX_VAR(opline->result.var), result);
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_INSTANCEOF_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *expr;
- zend_bool result;
-
- SAVE_OPLINE();
- expr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
- if (Z_TYPE_P(expr) == IS_OBJECT) {
- zend_class_entry *ce;
-
- if (IS_VAR == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, ZEND_FETCH_CLASS_NO_AUTOLOAD TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- ZVAL_FALSE(EX_VAR(opline->result.var));
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
- }
- result = instanceof_function(Z_OBJCE_P(expr), ce TSRMLS_CC);
- } else {
- result = 0;
- }
ZVAL_BOOL(EX_VAR(opline->result.var), result);
zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_YIELD_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_YIELD_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
}
/* Set the new yielded key */
- if (IS_VAR != IS_UNUSED) {
- zend_free_op free_op2;
- zval *key = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ if (IS_CV != IS_UNUSED) {
+
+ zval *key = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
/* Consts, temporary variables and references need copying */
- if (IS_VAR == IS_CONST) {
+ if (IS_CV == IS_CONST) {
ZVAL_DUP(&generator->key, key);
- } else if (IS_VAR == IS_TMP_VAR) {
+ } else if (IS_CV == IS_TMP_VAR) {
ZVAL_COPY_VALUE(&generator->key, key);
- } else if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && Z_ISREF_P(key)) {
+ } else if ((IS_CV == IS_VAR || IS_CV == IS_CV) && Z_ISREF_P(key)) {
ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
- zval_ptr_dtor_nogc(free_op2);
+
} else {
ZVAL_COPY_VALUE(&generator->key, key);
- if (IS_VAR == IS_CV) {
+ if (IS_CV == IS_CV) {
if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
}
}
ZEND_VM_RETURN();
}
-static int ZEND_FASTCALL ZEND_POW_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_POW_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
SAVE_OPLINE();
pow_function(EX_VAR(opline->result.var),
_get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
- zval_ptr_dtor_nogc(free_op2);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_TMP_UNUSED(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_TMP_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
- zval *varname;
- zval *retval;
- zend_string *name;
- HashTable *target_symbol_table;
+ zval *container;
+ zend_free_op free_op2;
+ zval *offset;
SAVE_OPLINE();
- varname = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+ container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_TMP_VAR == IS_CONST) {
- name = Z_STR_P(varname);
- } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
- name = Z_STR_P(varname);
- zend_string_addref(name);
+ if ((IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+ UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+ zend_error(E_NOTICE, "Trying to get property of non-object");
+ ZVAL_NULL(EX_VAR(opline->result.var));
} else {
- name = zval_get_string(varname);
- }
+ zval *retval;
- if (IS_UNUSED != IS_UNUSED) {
- zend_class_entry *ce;
+ /* here we are sure we are dealing with an object */
+ do {
+ if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
+ EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
+ zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
+ zend_object *zobj = Z_OBJ_P(container);
- if (IS_UNUSED == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- if (IS_TMP_VAR != IS_CONST) {
- zend_string_release(name);
- }
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
- }
- retval = zend_std_get_static_property(ce, name, 0, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
- } else {
- target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- retval = zend_hash_find(target_symbol_table, name);
- if (retval == NULL) {
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_UNSET:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_IS:
- retval = &EG(uninitialized_zval);
- break;
- case BP_VAR_RW:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_W:
- retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
- }
- /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
- } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
- retval = Z_INDIRECT_P(retval);
- if (Z_TYPE_P(retval) == IS_UNDEF) {
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_UNSET:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_IS:
- retval = &EG(uninitialized_zval);
+ if (EXPECTED(prop_info)) {
+ retval = OBJ_PROP(zobj, prop_info->offset);
+ if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
break;
- case BP_VAR_RW:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_W:
- ZVAL_NULL(retval);
+ }
+ } else if (EXPECTED(zobj->properties != NULL)) {
+ retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
+ if (EXPECTED(retval)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
break;
- EMPTY_SWITCH_DEFAULT_CASE()
+ }
}
}
- }
- if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
- if (Z_CONSTANT_P(retval)) {
- zval_update_constant(retval, 1 TSRMLS_CC);
- }
- } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
- zval_ptr_dtor_nogc(free_op1);
- }
- }
- if (IS_TMP_VAR != IS_CONST) {
- zend_string_release(name);
- }
+ retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
- ZEND_ASSERT(retval != NULL);
- if (type == BP_VAR_R || type == BP_VAR_IS) {
- if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
- ZVAL_UNREF(retval);
- }
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- } else {
- ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
+ if (retval != EX_VAR(opline->result.var)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ }
+ } while (0);
}
+
+ zval_ptr_dtor_nogc(free_op2);
+ zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_R_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_TMP_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_fetch_var_address_helper_SPEC_TMP_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ USE_OPLINE
+ zend_free_op free_op1;
+ zval *container;
+ zend_free_op free_op2;
+ zval *offset;
-static int ZEND_FASTCALL ZEND_FETCH_W_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_TMP_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ SAVE_OPLINE();
+ container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-static int ZEND_FASTCALL ZEND_FETCH_RW_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_TMP_UNUSED(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ if ((IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+ UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ } else {
+ zval *retval;
-static int ZEND_FASTCALL ZEND_FETCH_FUNC_ARG_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ /* here we are sure we are dealing with an object */
+ do {
+ if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
+ EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
+ zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
+ zend_object *zobj = Z_OBJ_P(container);
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- return zend_fetch_var_address_helper_SPEC_TMP_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else {
- return zend_fetch_var_address_helper_SPEC_TMP_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
+ if (EXPECTED(prop_info)) {
+ retval = OBJ_PROP(zobj, prop_info->offset);
+ if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
+ }
+ } else if (EXPECTED(zobj->properties != NULL)) {
+ retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
+ if (EXPECTED(retval)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
+ }
+ }
+ }
-static int ZEND_FASTCALL ZEND_FETCH_UNSET_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_TMP_UNUSED(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
-static int ZEND_FASTCALL ZEND_FETCH_IS_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_TMP_UNUSED(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ if (retval != EX_VAR(opline->result.var)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ }
+ } while (0);
+ }
+
+ zval_ptr_dtor_nogc(free_op2);
+ zval_ptr_dtor_nogc(free_op1);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_TMP_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *container;
- zend_free_op free_op1;
-
- SAVE_OPLINE();
if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+ /* Behave like FETCH_OBJ_W */
+ zend_free_op free_op1, free_op2;
+ zval *property;
+
+ SAVE_OPLINE();
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ container = NULL;
+
if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
}
- container = NULL;
if (IS_TMP_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
}
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_TMP_VAR, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
if (IS_TMP_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
-
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
} else {
- if (IS_UNUSED == IS_UNUSED) {
- zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
- }
- container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
-
- zval_ptr_dtor_nogc(free_op1);
+ return ZEND_FETCH_OBJ_R_SPEC_TMP_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ADD_VAR_SPEC_TMP_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *expr_ptr, new_expr;
+ zend_free_op free_op2;
+ zval *str = EX_VAR(opline->result.var);
+ zval *var;
+ zval var_copy;
+ int use_copy = 0;
SAVE_OPLINE();
- if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) &&
- (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
- expr_ptr = NULL;
- if (IS_TMP_VAR == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
- }
- ZVAL_MAKE_REF(expr_ptr);
- Z_ADDREF_P(expr_ptr);
+ var = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- } else {
- expr_ptr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- if (IS_TMP_VAR == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&new_expr, expr_ptr);
- expr_ptr = &new_expr;
- } else if (IS_TMP_VAR == IS_CONST) {
- if (!Z_IMMUTABLE_P(expr_ptr)) {
- ZVAL_DUP(&new_expr, expr_ptr);
- expr_ptr = &new_expr;
- }
- } else if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) && Z_ISREF_P(expr_ptr)) {
- expr_ptr = Z_REFVAL_P(expr_ptr);
- if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
+ if (IS_TMP_VAR == IS_UNUSED) {
+ /* Initialize for erealloc in add_string_to_string */
+ ZVAL_EMPTY_STRING(str);
+ }
- } else if (IS_TMP_VAR == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
- Z_ADDREF_P(expr_ptr);
+ if (Z_TYPE_P(var) != IS_STRING) {
+ use_copy = zend_make_printable_zval(var, &var_copy TSRMLS_CC);
+
+ if (use_copy) {
+ var = &var_copy;
}
}
+ add_string_to_string(str, str, var);
- if (IS_UNUSED != IS_UNUSED) {
+ if (use_copy) {
+ zend_string_release(Z_STR_P(var));
+ }
+ /* original comment, possibly problematic:
+ * FREE_OP is missing intentionally here - we're always working on the same temporary variable
+ * (Zeev): I don't think it's problematic, we only use variables
+ * which aren't affected by FREE_OP(Ts, )'s anyway, unless they're
+ * string offsets or overloaded objects
+ */
+ zval_ptr_dtor_nogc(free_op2);
- zval *offset = NULL;
- zend_string *str;
- zend_ulong hval;
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
-add_again:
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- goto num_index;
+static int ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_TMP_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zval *function_name;
+ zend_free_op free_op1, free_op2;
+ zval *object;
+ zend_function *fbc;
+ zend_class_entry *called_scope;
+ zend_object *obj;
+
+ SAVE_OPLINE();
+
+ function_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST &&
+ UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ zend_error_noreturn(E_ERROR, "Method name must be a string");
+ }
+
+ object = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+
+ if (IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ uint32_t nesting = 1;
+
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ zval_ptr_dtor_nogc(free_op2);
+ HANDLE_EXCEPTION();
+ }
+
+ zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s", Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
+ zval_ptr_dtor_nogc(free_op2);
+
+ if (EG(exception) != NULL) {
+ HANDLE_EXCEPTION();
+ }
+
+ /* No exception raised: Skip over arguments until fcall opcode with correct
+ * nesting level. Return NULL (except when return value unused) */
+ do {
+ opline++;
+ if (opline->opcode == ZEND_INIT_FCALL ||
+ opline->opcode == ZEND_INIT_FCALL_BY_NAME ||
+ opline->opcode == ZEND_INIT_NS_FCALL_BY_NAME ||
+ opline->opcode == ZEND_INIT_METHOD_CALL ||
+ opline->opcode == ZEND_INIT_STATIC_METHOD_CALL ||
+ opline->opcode == ZEND_INIT_USER_CALL ||
+ opline->opcode == ZEND_NEW
+ ) {
+ nesting++;
+ } else if (opline->opcode == ZEND_DO_FCALL) {
+ nesting--;
+ }
+ } while (nesting);
+
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+
+ /* We've skipped EXT_FCALL_BEGIND, so also skip the ending opcode */
+ if ((opline + 1)->opcode == ZEND_EXT_FCALL_END) {
+ opline++;
+ }
+ ZEND_VM_JMP(++opline);
+ }
+
+ obj = Z_OBJ_P(object);
+ called_scope = obj->ce;
+
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST ||
+ EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
+ zend_object *orig_obj = obj;
+
+ if (UNEXPECTED(obj->handlers->get_method == NULL)) {
+ zend_error_noreturn(E_ERROR, "Object does not support method calls");
+ }
+
+ /* First, locate the function. */
+ fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
+ if (UNEXPECTED(fbc == NULL)) {
+ zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
+ }
+ if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
+ EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
+ EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
+ EXPECTED(obj == orig_obj)) {
+ CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope, fbc);
+ }
+ }
+
+ if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_STATIC) != 0)) {
+ obj = NULL;
+ } else {
+ GC_REFCOUNT(obj)++; /* For $this pointer */
+ }
+
+ EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
+ fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
+
+ zval_ptr_dtor_nogc(free_op2);
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+ zval *expr_ptr, new_expr;
+
+ SAVE_OPLINE();
+ if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) &&
+ (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
+ expr_ptr = NULL;
+ if (IS_TMP_VAR == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
+ }
+ ZVAL_MAKE_REF(expr_ptr);
+ Z_ADDREF_P(expr_ptr);
+
+ } else {
+ expr_ptr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+ if (IS_TMP_VAR == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&new_expr, expr_ptr);
+ expr_ptr = &new_expr;
+ } else if (IS_TMP_VAR == IS_CONST) {
+ if (!Z_IMMUTABLE_P(expr_ptr)) {
+ ZVAL_DUP(&new_expr, expr_ptr);
+ expr_ptr = &new_expr;
+ }
+ } else if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) && Z_ISREF_P(expr_ptr)) {
+ expr_ptr = Z_REFVAL_P(expr_ptr);
+ if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
+
+ } else if (IS_TMP_VAR == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
+ Z_ADDREF_P(expr_ptr);
+ }
+ }
+
+ if ((IS_TMP_VAR|IS_VAR) != IS_UNUSED) {
+ zend_free_op free_op2;
+ zval *offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ zend_string *str;
+ zend_ulong hval;
+
+add_again:
+ switch (Z_TYPE_P(offset)) {
+ case IS_DOUBLE:
+ hval = zend_dval_to_lval(Z_DVAL_P(offset));
+ goto num_index;
case IS_LONG:
hval = Z_LVAL_P(offset);
num_index:
break;
case IS_STRING:
str = Z_STR_P(offset);
- if (IS_UNUSED != IS_CONST) {
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
if (ZEND_HANDLE_NUMERIC(str, hval)) {
goto num_index;
}
/* do nothing */
break;
}
-
+ zval_ptr_dtor_nogc(free_op2);
} else {
zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_TMP_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
zval *array;
uint32_t size;
ZEND_VM_NEXT_OPCODE();
#if 0 || IS_TMP_VAR != IS_UNUSED
} else {
- return ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
#endif
}
}
-static int ZEND_FASTCALL ZEND_UNSET_VAR_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval tmp, *varname;
- HashTable *target_symbol_table;
- zend_free_op free_op1;
+ zend_free_op free_op1, free_op2;
+ zval *container;
+ int result;
+ zend_ulong hval;
+ zval *offset;
SAVE_OPLINE();
- if (IS_TMP_VAR == IS_CV &&
- IS_UNUSED == IS_UNUSED &&
- (opline->extended_value & ZEND_QUICK_SET)) {
- zval *var = EX_VAR(opline->op1.var);
-
- if (Z_REFCOUNTED_P(var)) {
- zend_refcounted *garbage = Z_COUNTED_P(var);
-
- if (!--GC_REFCOUNT(garbage)) {
- ZVAL_UNDEF(var);
- _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
- } else {
- GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
- ZVAL_UNDEF(var);
- }
- } else {
- ZVAL_UNDEF(var);
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-
- varname = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
- ZVAL_UNDEF(&tmp);
- if (IS_TMP_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
- ZVAL_STR(&tmp, zval_get_string(varname));
- varname = &tmp;
- }
+ container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_UNUSED != IS_UNUSED) {
- zend_class_entry *ce;
+ if (IS_TMP_VAR != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
+ HashTable *ht = Z_ARRVAL_P(container);
+ zval *value;
+ zend_string *str;
- if (IS_UNUSED == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(EG(exception) != NULL)) {
- if (IS_TMP_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
- }
- zval_ptr_dtor_nogc(free_op1);
- HANDLE_EXCEPTION();
- }
- if (UNEXPECTED(ce == NULL)) {
- zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
+isset_again:
+ if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
+ str = Z_STR_P(offset);
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+ if (ZEND_HANDLE_NUMERIC(str, hval)) {
+ goto num_index_prop;
}
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
}
+str_index_prop:
+ value = zend_hash_find_ind(ht, str);
+ } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
+ hval = Z_LVAL_P(offset);
+num_index_prop:
+ value = zend_hash_index_find(ht, hval);
} else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
+ switch (Z_TYPE_P(offset)) {
+ case IS_DOUBLE:
+ hval = zend_dval_to_lval(Z_DVAL_P(offset));
+ goto num_index_prop;
+ case IS_NULL:
+ str = STR_EMPTY_ALLOC();
+ goto str_index_prop;
+ case IS_FALSE:
+ hval = 0;
+ goto num_index_prop;
+ case IS_TRUE:
+ hval = 1;
+ goto num_index_prop;
+ case IS_RESOURCE:
+ hval = Z_RES_HANDLE_P(offset);
+ goto num_index_prop;
+ case IS_REFERENCE:
+ offset = Z_REFVAL_P(offset);
+ goto isset_again;
+ default:
+ zend_error(E_WARNING, "Illegal offset type in isset or empty");
+ value = NULL;
+ break;
+ }
}
- zend_std_unset_static_property(ce, Z_STR_P(varname), ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
- } else {
- target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
- }
-
- if (IS_TMP_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
- }
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_VAR_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *value;
- SAVE_OPLINE();
- if (IS_TMP_VAR == IS_CV &&
- IS_UNUSED == IS_UNUSED &&
- (opline->extended_value & ZEND_QUICK_SET)) {
- value = EX_VAR(opline->op1.var);
if (opline->extended_value & ZEND_ISSET) {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+ /* > IS_NULL means not IS_UNDEF and not IS_NULL */
+ result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
+ (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
} else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- !i_zend_is_true(value TSRMLS_CC));
- CHECK_EXCEPTION();
- }
- ZEND_VM_NEXT_OPCODE();
- } else {
- zend_free_op free_op1;
- zval tmp, *varname = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
- ZVAL_UNDEF(&tmp);
- if (IS_TMP_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
- ZVAL_STR(&tmp, zval_get_string(varname));
- varname = &tmp;
+ result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
}
-
- if (IS_UNUSED != IS_UNUSED) {
- zend_class_entry *ce;
-
- if (IS_UNUSED == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
- }
- value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+ } else if (IS_TMP_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
+ result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
} else {
- HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
- }
-
- if (IS_TMP_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
+ zend_error(E_NOTICE, "Trying to check element of non-array");
+ result = 0;
}
- zval_ptr_dtor_nogc(free_op1);
-
- if (opline->extended_value & ZEND_ISSET) {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- value && Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- !value || !i_zend_is_true(value TSRMLS_CC));
+ if ((opline->extended_value & ZEND_ISSET) == 0) {
+ result = !result;
}
+ } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
+ zval tmp;
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-}
-
-static int ZEND_FASTCALL ZEND_YIELD_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- /* The generator object is stored in EX(return_value) */
- zend_generator *generator = (zend_generator *) EX(return_value);
-
- if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
- zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
- }
-
- /* Destroy the previously yielded value */
- zval_ptr_dtor(&generator->value);
-
- /* Destroy the previously yielded key */
- zval_ptr_dtor(&generator->key);
-
- /* Set the new yielded value */
- if (IS_TMP_VAR != IS_UNUSED) {
- zend_free_op free_op1;
-
- if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
- /* Constants and temporary variables aren't yieldable by reference,
- * but we still allow them with a notice. */
- if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
- zval *value;
-
- zend_error(E_NOTICE, "Only variable references should be yielded by reference");
-
- value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- ZVAL_COPY_VALUE(&generator->value, value);
- if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
-
- /* Temporary variables don't need ctor copying */
- if (IS_TMP_VAR != IS_TMP_VAR) {
- zval_opt_copy_ctor(&generator->value);
- }
- } else {
- zval *value_ptr = NULL;
-
- if (IS_TMP_VAR == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
- }
-
- /* If a function call result is yielded and the function did
- * not return by reference we throw a notice. */
- if (IS_TMP_VAR == IS_VAR &&
- (value_ptr == &EG(uninitialized_zval) ||
- (opline->extended_value == ZEND_RETURNS_FUNCTION &&
- !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
- zend_error(E_NOTICE, "Only variable references should be yielded by reference");
- } else {
- ZVAL_MAKE_REF(value_ptr);
- }
- ZVAL_COPY(&generator->value, value_ptr);
-
+ result = 0;
+ if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
+ if ((IS_TMP_VAR|IS_VAR) & (IS_CV|IS_VAR)) {
+ ZVAL_DEREF(offset);
}
- } else {
- zval *value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
- /* Consts, temporary variables and references need copying */
- if (IS_TMP_VAR == IS_CONST) {
- ZVAL_DUP(&generator->value, value);
- } else if (IS_TMP_VAR == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&generator->value, value);
- } else if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) && Z_ISREF_P(value)) {
- ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
-
- } else {
- ZVAL_COPY_VALUE(&generator->value, value);
- if (IS_TMP_VAR == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+ if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
+ || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
+ && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
+ ZVAL_DUP(&tmp, offset);
+ convert_to_long(&tmp);
+ offset = &tmp;
+ }
+ }
+ if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
+ if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
+ if ((opline->extended_value & ZEND_ISSET) ||
+ Z_STRVAL_P(container)[offset->value.lval] != '0') {
+ result = 1;
}
}
}
+ if ((opline->extended_value & ZEND_ISSET) == 0) {
+ result = !result;
+ }
} else {
- /* If no value was specified yield null */
- ZVAL_NULL(&generator->value);
+ result = ((opline->extended_value & ZEND_ISSET) == 0);
}
- /* Set the new yielded key */
- if (IS_UNUSED != IS_UNUSED) {
+ zval_ptr_dtor_nogc(free_op2);
+ ZVAL_BOOL(EX_VAR(opline->result.var), result);
+ zval_ptr_dtor_nogc(free_op1);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- zval *key = NULL;
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_TMP_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1, free_op2;
+ zval *container;
+ int result;
+ zval *offset;
- /* Consts, temporary variables and references need copying */
- if (IS_UNUSED == IS_CONST) {
- ZVAL_DUP(&generator->key, key);
- } else if (IS_UNUSED == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&generator->key, key);
- } else if ((IS_UNUSED == IS_VAR || IS_UNUSED == IS_CV) && Z_ISREF_P(key)) {
- ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
+ SAVE_OPLINE();
+ container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ if (IS_TMP_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
+ result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
} else {
- ZVAL_COPY_VALUE(&generator->key, key);
- if (IS_UNUSED == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
- }
+ zend_error(E_NOTICE, "Trying to check property of non-object");
+ result = 0;
}
-
- if (Z_TYPE(generator->key) == IS_LONG
- && Z_LVAL(generator->key) > generator->largest_used_integer_key
- ) {
- generator->largest_used_integer_key = Z_LVAL(generator->key);
+ if ((opline->extended_value & ZEND_ISSET) == 0) {
+ result = !result;
}
} else {
- /* If no key was specified we use auto-increment keys */
- generator->largest_used_integer_key++;
- ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
- }
-
- if (RETURN_VALUE_USED(opline)) {
- /* If the return value of yield is used set the send
- * target and initialize it to NULL */
- generator->send_target = EX_VAR(opline->result.var);
- ZVAL_NULL(generator->send_target);
- } else {
- generator->send_target = NULL;
+ result = ((opline->extended_value & ZEND_ISSET) == 0);
}
- /* We increment to the next op, so we are at the correct position when the
- * generator is resumed. */
- ZEND_VM_INC_OPCODE();
-
- /* The GOTO VM uses a local opline variable. We need to set the opline
- * variable in execute_data so we don't resume at an old position. */
- SAVE_OPLINE();
-
- ZEND_VM_RETURN();
+ zval_ptr_dtor_nogc(free_op2);
+ ZVAL_BOOL(EX_VAR(opline->result.var), result);
+ zval_ptr_dtor_nogc(free_op1);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_MOD_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BW_NOT_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
SAVE_OPLINE();
- fast_mod_function(EX_VAR(opline->result.var),
- _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ bitwise_not_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
-
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_SL_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BOOL_NOT_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
SAVE_OPLINE();
- shift_left_function(EX_VAR(opline->result.var),
- _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ boolean_not_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
-
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_SR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_PRE_INC_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
+ zval *var_ptr;
SAVE_OPLINE();
- shift_right_function(EX_VAR(opline->result.var),
- _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
+ var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
+ }
-static int ZEND_FASTCALL ZEND_CONCAT_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
+ if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
+ fast_increment_function(var_ptr);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
+ }
+ ZEND_VM_NEXT_OPCODE();
+ }
- SAVE_OPLINE();
- concat_function(EX_VAR(opline->result.var),
- _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
+ if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
+
+ increment_function(var_ptr);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+ }
+
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_IS_IDENTICAL_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_PRE_DEC_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
+ zval *var_ptr;
SAVE_OPLINE();
- fast_is_identical_function(EX_VAR(opline->result.var),
- _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
+ var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+
+ if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
+ }
+
+ if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
+ fast_decrement_function(var_ptr);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
+ }
+ ZEND_VM_NEXT_OPCODE();
+ }
+
+ if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
+
+ decrement_function(var_ptr);
+
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+ }
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_IS_NOT_IDENTICAL_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_POST_INC_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
- zval *result = EX_VAR(opline->result.var);
+ zval *var_ptr;
SAVE_OPLINE();
- fast_is_not_identical_function(result,
- _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
+ var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+
+ if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
+ }
+
+ if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
+ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
+ fast_increment_function(var_ptr);
+ ZEND_VM_NEXT_OPCODE();
+ }
+
+ if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+
+ ZVAL_DEREF(var_ptr);
+ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
+ zval_opt_copy_ctor(var_ptr);
+ increment_function(var_ptr);
+
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_BW_OR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_POST_DEC_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
+ zval *var_ptr;
SAVE_OPLINE();
- bitwise_or_function(EX_VAR(opline->result.var),
- _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
+ var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+
+ if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
+ }
+
+ if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
+ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
+ fast_decrement_function(var_ptr);
+ ZEND_VM_NEXT_OPCODE();
+ }
+
+ if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+
+ ZVAL_DEREF(var_ptr);
+ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
+ zval_opt_copy_ctor(var_ptr);
+
+ decrement_function(var_ptr);
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_BW_AND_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ECHO_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
+ zval *z;
SAVE_OPLINE();
- bitwise_and_function(EX_VAR(opline->result.var),
- _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
+ z = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
+
+ zend_print_variable(z TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_BW_XOR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_PRINT_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
- SAVE_OPLINE();
- bitwise_xor_function(EX_VAR(opline->result.var),
- _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ ZVAL_LONG(EX_VAR(opline->result.var), 1);
+ return ZEND_ECHO_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_BOOL_XOR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_JMPZ_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
+ zval *val;
SAVE_OPLINE();
- boolean_xor_function(EX_VAR(opline->result.var),
- _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
+ val = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (IS_VAR == IS_TMP_VAR) {
+ if (Z_TYPE_P(val) == IS_TRUE) {
+ ZEND_VM_SET_OPCODE(opline + 1);
+ ZEND_VM_CONTINUE();
+ } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+ ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+ ZEND_VM_CONTINUE();
+ }
+ }
+
+ if (i_zend_is_true(val TSRMLS_CC)) {
+ opline++;
+ } else {
+ opline = opline->op2.jmp_addr;
+ }
+ zval_ptr_dtor_nogc(free_op1);
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ ZEND_VM_JMP(opline);
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_JMPNZ_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
- zval *container;
+ zval *val;
SAVE_OPLINE();
- container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
+ val = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
+
+ if (IS_VAR == IS_TMP_VAR) {
+ if (Z_TYPE_P(val) == IS_TRUE) {
+ ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+ ZEND_VM_CONTINUE();
+ } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+ ZEND_VM_SET_OPCODE(opline + 1);
+ ZEND_VM_CONTINUE();
+ }
+ }
+ if (i_zend_is_true(val TSRMLS_CC)) {
+ opline = opline->op2.jmp_addr;
+ } else {
+ opline++;
+ }
zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ ZEND_VM_JMP(opline);
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_IS_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_JMPZNZ_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
- zval *container;
+ zval *val;
SAVE_OPLINE();
- container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
+ val = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
+
+ if (IS_VAR == IS_TMP_VAR) {
+ if (EXPECTED(Z_TYPE_P(val) == IS_TRUE)) {
+ ZEND_VM_SET_RELATIVE_OPCODE(opline, opline->extended_value);
+ ZEND_VM_CONTINUE();
+ } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+ ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+ ZEND_VM_CONTINUE();
+ }
+ }
+ if (i_zend_is_true(val TSRMLS_CC)) {
+ opline = (zend_op*)(((char*)opline) + opline->extended_value);
+ } else {
+ opline = opline->op2.jmp_addr;
+ }
zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ ZEND_VM_JMP(opline);
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_JMPZ_EX_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *container;
zend_free_op free_op1;
+ zval *val;
SAVE_OPLINE();
+ val = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
- zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
- }
- container = NULL;
- if (IS_TMP_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
- if (IS_TMP_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ if (IS_VAR == IS_TMP_VAR) {
+ if (Z_TYPE_P(val) == IS_TRUE) {
+ ZVAL_TRUE(EX_VAR(opline->result.var));
+ ZEND_VM_SET_OPCODE(opline + 1);
+ ZEND_VM_CONTINUE();
+ } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+ ZVAL_FALSE(EX_VAR(opline->result.var));
+ ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+ ZEND_VM_CONTINUE();
}
+ }
-
+ if (i_zend_is_true(val TSRMLS_CC)) {
+ zval_ptr_dtor_nogc(free_op1);
+ ZVAL_TRUE(EX_VAR(opline->result.var));
+ opline++;
} else {
- if (IS_CV == IS_UNUSED) {
- zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
- }
- container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
-
zval_ptr_dtor_nogc(free_op1);
+ ZVAL_FALSE(EX_VAR(opline->result.var));
+ opline = opline->op2.jmp_addr;
}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ ZEND_VM_JMP(opline);
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_JMPNZ_EX_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
- zval *container;
-
- zval *offset;
+ zval *val;
SAVE_OPLINE();
- container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ val = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
- if ((IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
- UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
- zend_error(E_NOTICE, "Trying to get property of non-object");
- ZVAL_NULL(EX_VAR(opline->result.var));
+ if (IS_VAR == IS_TMP_VAR) {
+ if (Z_TYPE_P(val) == IS_TRUE) {
+ ZVAL_TRUE(EX_VAR(opline->result.var));
+ ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+ ZEND_VM_CONTINUE();
+ } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+ ZVAL_FALSE(EX_VAR(opline->result.var));
+ ZEND_VM_SET_OPCODE(opline + 1);
+ ZEND_VM_CONTINUE();
+ }
+ }
+ if (i_zend_is_true(val TSRMLS_CC)) {
+ ZVAL_TRUE(EX_VAR(opline->result.var));
+ opline = opline->op2.jmp_addr;
} else {
- zval *retval;
-
- /* here we are sure we are dealing with an object */
- do {
- if (IS_CV == IS_CONST &&
- EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
- zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
- zend_object *zobj = Z_OBJ_P(container);
-
- if (EXPECTED(prop_info)) {
- retval = OBJ_PROP(zobj, prop_info->offset);
- if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- } else if (EXPECTED(zobj->properties != NULL)) {
- retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
- if (EXPECTED(retval)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- }
- }
-
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
-
- if (retval != EX_VAR(opline->result.var)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- }
- } while (0);
+ ZVAL_FALSE(EX_VAR(opline->result.var));
+ opline++;
}
-
zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ ZEND_VM_JMP(opline);
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_RETURN_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *retval_ptr;
zend_free_op free_op1;
- zval *container;
-
- zval *offset;
SAVE_OPLINE();
- container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ retval_ptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- if ((IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
- UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
+ if (!EX(return_value)) {
+ zval_ptr_dtor_nogc(free_op1);
} else {
- zval *retval;
-
- /* here we are sure we are dealing with an object */
- do {
- if (IS_CV == IS_CONST &&
- EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
- zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
- zend_object *zobj = Z_OBJ_P(container);
-
- if (EXPECTED(prop_info)) {
- retval = OBJ_PROP(zobj, prop_info->offset);
- if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- } else if (EXPECTED(zobj->properties != NULL)) {
- retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
- if (EXPECTED(retval)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
+ if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
+ if (IS_VAR == IS_CONST) {
+ if (UNEXPECTED(Z_OPT_COPYABLE_P(EX(return_value)))) {
+ zval_copy_ctor_func(EX(return_value));
}
}
-
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
-
- if (retval != EX_VAR(opline->result.var)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ } else if ((IS_VAR == IS_CV || IS_VAR == IS_VAR) && Z_ISREF_P(retval_ptr)) {
+ ZVAL_COPY(EX(return_value), Z_REFVAL_P(retval_ptr));
+ zval_ptr_dtor_nogc(free_op1);
+ } else {
+ ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
+ if (IS_VAR == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(retval_ptr)) Z_ADDREF_P(retval_ptr);
}
- } while (0);
+ }
}
-
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_RETURN_BY_REF_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *container;
+ zval *retval_ptr;
+ zend_free_op free_op1;
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- /* Behave like FETCH_OBJ_W */
- zend_free_op free_op1;
- zval *property;
+ SAVE_OPLINE();
- SAVE_OPLINE();
- property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
- container = NULL;
+ do {
+ if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR ||
+ (IS_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_VALUE)) {
+ /* Not supposed to happen, but we'll allow it */
+ zend_error(E_NOTICE, "Only variable references should be returned by reference");
- if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
- zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
- }
- if (IS_TMP_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+ retval_ptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+ if (!EX(return_value)) {
+ if (IS_VAR == IS_TMP_VAR) {
+ zval_ptr_dtor_nogc(free_op1);
+ }
+ } else {
+ ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
+ Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
+ if (IS_VAR != IS_TMP_VAR) {
+ zval_opt_copy_ctor_no_imm(EX(return_value));
+ }
+ }
+ break;
}
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_TMP_VAR, property, IS_CV, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
- if (IS_TMP_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ retval_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+
+ if (IS_VAR == IS_VAR && UNEXPECTED(retval_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot return string offsets by reference");
}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- } else {
- return ZEND_FETCH_OBJ_R_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
+ if (IS_VAR == IS_VAR) {
+ if (retval_ptr == &EG(uninitialized_zval) ||
+ (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+ !(Z_VAR_FLAGS_P(retval_ptr) & IS_VAR_RET_REF))) {
+ zend_error(E_NOTICE, "Only variable references should be returned by reference");
+ if (EX(return_value)) {
+ ZVAL_NEW_REF(EX(return_value), retval_ptr);
+ Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
+ if (Z_REFCOUNTED_P(retval_ptr)) Z_ADDREF_P(retval_ptr);
+ }
+ break;
+ }
+ }
+
+ if (EX(return_value)) {
+ ZVAL_MAKE_REF(retval_ptr);
+ Z_ADDREF_P(retval_ptr);
+ ZVAL_REF(EX(return_value), Z_REF_P(retval_ptr));
+ Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
+ }
+ } while (0);
+
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+ return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_ADD_VAR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_THROW_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
- zval *str = EX_VAR(opline->result.var);
- zval *var;
- zval var_copy;
- int use_copy = 0;
+ zval *value;
+ zend_free_op free_op1;
SAVE_OPLINE();
- var = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ value = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
- if (IS_TMP_VAR == IS_UNUSED) {
- /* Initialize for erealloc in add_string_to_string */
- ZVAL_EMPTY_STRING(str);
+ if (IS_VAR == IS_CONST || UNEXPECTED(Z_TYPE_P(value) != IS_OBJECT)) {
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ zend_error_noreturn(E_ERROR, "Can only throw objects");
}
- if (Z_TYPE_P(var) != IS_STRING) {
- if (IS_CV != IS_TMP_VAR) {
- ZVAL_DEREF(var);
- }
- if (Z_TYPE_P(var) != IS_STRING) {
- use_copy = zend_make_printable_zval(var, &var_copy TSRMLS_CC);
-
- if (use_copy) {
- var = &var_copy;
- }
- }
+ zend_exception_save(TSRMLS_C);
+ if (IS_VAR != IS_TMP_VAR) {
+ if (Z_REFCOUNTED_P(value)) Z_ADDREF_P(value);
}
- add_string_to_string(str, str, var);
- if (use_copy) {
- zend_string_release(Z_STR_P(var));
- }
- /* original comment, possibly problematic:
- * FREE_OP is missing intentionally here - we're always working on the same temporary variable
- * (Zeev): I don't think it's problematic, we only use variables
- * which aren't affected by FREE_OP(Ts, )'s anyway, unless they're
- * string offsets or overloaded objects
- */
+ zend_throw_exception_object(value TSRMLS_CC);
+ zend_exception_restore(TSRMLS_C);
+ zval_ptr_dtor_nogc(free_op1);
+ HANDLE_EXCEPTION();
+}
- CHECK_EXCEPTION();
+static int ZEND_FASTCALL ZEND_SEND_VAR_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zval *varptr, *arg;
+ zend_free_op free_op1;
+
+ varptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+ arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
+ ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
+ if (Z_ISREF_P(varptr)) {
+ ZVAL_COPY(arg, Z_REFVAL_P(varptr));
+ zval_ptr_dtor_nogc(free_op1);
+ } else {
+ ZVAL_COPY_VALUE(arg, varptr);
+ if (IS_VAR == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(arg)) Z_ADDREF_P(arg);
+ }
+ }
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SEND_VAR_NO_REF_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *function_name;
zend_free_op free_op1;
- zval *object;
- zend_function *fbc;
- zend_class_entry *called_scope;
- zend_object *obj;
+ zval *varptr, *arg;
SAVE_OPLINE();
- function_name = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
-
- if (IS_CV != IS_CONST &&
- UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
+ if (!(opline->extended_value & ZEND_ARG_COMPILE_TIME_BOUND)) {
+ if (!ARG_SHOULD_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
+ return ZEND_SEND_VAR_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
- zend_error_noreturn(E_ERROR, "Method name must be a string");
}
- object = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
- if (IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- uint32_t nesting = 1;
-
- if (UNEXPECTED(EG(exception) != NULL)) {
+ varptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+ if ((!(opline->extended_value & ZEND_ARG_SEND_FUNCTION) ||
+ (Z_VAR_FLAGS_P(varptr) & IS_VAR_RET_REF)) &&
+ (Z_ISREF_P(varptr) || Z_TYPE_P(varptr) == IS_OBJECT)) {
- HANDLE_EXCEPTION();
+ ZVAL_MAKE_REF(varptr);
+ if (IS_VAR == IS_CV) {
+ Z_ADDREF_P(varptr);
}
-
- zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s", Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
-
-
- if (EG(exception) != NULL) {
- HANDLE_EXCEPTION();
+ } else {
+ if ((opline->extended_value & ZEND_ARG_COMPILE_TIME_BOUND) ?
+ !(opline->extended_value & ZEND_ARG_SEND_SILENT) :
+ !ARG_MAY_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
+ zend_error(E_STRICT, "Only variables should be passed by reference");
}
+ }
- /* No exception raised: Skip over arguments until fcall opcode with correct
- * nesting level. Return NULL (except when return value unused) */
- do {
- opline++;
- if (opline->opcode == ZEND_INIT_FCALL ||
- opline->opcode == ZEND_INIT_FCALL_BY_NAME ||
- opline->opcode == ZEND_INIT_NS_FCALL_BY_NAME ||
- opline->opcode == ZEND_INIT_METHOD_CALL ||
- opline->opcode == ZEND_INIT_STATIC_METHOD_CALL ||
- opline->opcode == ZEND_INIT_USER_CALL ||
- opline->opcode == ZEND_NEW
- ) {
- nesting++;
- } else if (opline->opcode == ZEND_DO_FCALL) {
- nesting--;
- }
- } while (nesting);
-
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
+ arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
+ ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
+ ZVAL_COPY_VALUE(arg, varptr);
- /* We've skipped EXT_FCALL_BEGIND, so also skip the ending opcode */
- if ((opline + 1)->opcode == ZEND_EXT_FCALL_END) {
- opline++;
- }
- ZEND_VM_JMP(++opline);
- }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- obj = Z_OBJ_P(object);
- called_scope = obj->ce;
+static int ZEND_FASTCALL ZEND_SEND_REF_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+ zval *varptr, *arg;
- if (IS_CV != IS_CONST ||
- EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
- zend_object *orig_obj = obj;
+ SAVE_OPLINE();
+ varptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (UNEXPECTED(obj->handlers->get_method == NULL)) {
- zend_error_noreturn(E_ERROR, "Object does not support method calls");
- }
+ if (IS_VAR == IS_VAR && UNEXPECTED(varptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Only variables can be passed by reference");
+ }
- /* First, locate the function. */
- fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_CV == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
- if (UNEXPECTED(fbc == NULL)) {
- zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
- }
- if (IS_CV == IS_CONST &&
- EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
- EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
- EXPECTED(obj == orig_obj)) {
- CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope, fbc);
- }
+ arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
+ ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
+ if (IS_VAR == IS_VAR && UNEXPECTED(varptr == &EG(error_zval))) {
+ ZVAL_NEW_REF(arg, &EG(uninitialized_zval));
+ ZEND_VM_NEXT_OPCODE();
}
- if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_STATIC) != 0)) {
- obj = NULL;
+ if (Z_ISREF_P(varptr)) {
+ Z_ADDREF_P(varptr);
+ ZVAL_COPY_VALUE(arg, varptr);
+ } else if (IS_VAR == IS_VAR &&
+ UNEXPECTED(Z_TYPE_P(EX_VAR(opline->op1.var)) != IS_INDIRECT)) {
+ ZVAL_NEW_REF(arg, varptr);
} else {
- GC_REFCOUNT(obj)++; /* For $this pointer */
+ ZVAL_NEW_REF(arg, varptr);
+ Z_ADDREF_P(arg);
+ ZVAL_REF(varptr, Z_REF_P(arg));
}
- EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
- fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
-
-
- CHECK_EXCEPTION();
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_CASE_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SEND_VAR_EX_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *varptr, *arg;
zend_free_op free_op1;
- zval *result = EX_VAR(opline->result.var);
-
- SAVE_OPLINE();
- fast_equal_function(result,
- _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
- CHECK_EXCEPTION();
+ if (ARG_SHOULD_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
+ return ZEND_SEND_REF_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+ varptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+ arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
+ ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
+ if (Z_ISREF_P(varptr)) {
+ ZVAL_COPY(arg, Z_REFVAL_P(varptr));
+ zval_ptr_dtor_nogc(free_op1);
+ } else {
+ ZVAL_COPY_VALUE(arg, varptr);
+ if (IS_VAR == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(arg)) Z_ADDREF_P(arg);
+ }
+ }
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SEND_USER_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *arg, *param, tmp;
zend_free_op free_op1;
- zval *expr_ptr, new_expr;
-
- SAVE_OPLINE();
- if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) &&
- (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
- expr_ptr = NULL;
- if (IS_TMP_VAR == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
- }
- ZVAL_MAKE_REF(expr_ptr);
- Z_ADDREF_P(expr_ptr);
- } else {
- expr_ptr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- if (IS_TMP_VAR == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&new_expr, expr_ptr);
- expr_ptr = &new_expr;
- } else if (IS_TMP_VAR == IS_CONST) {
- if (!Z_IMMUTABLE_P(expr_ptr)) {
- ZVAL_DUP(&new_expr, expr_ptr);
- expr_ptr = &new_expr;
- }
- } else if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) && Z_ISREF_P(expr_ptr)) {
- expr_ptr = Z_REFVAL_P(expr_ptr);
- if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
+ arg = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+ param = ZEND_CALL_ARG(EX(call), opline->op2.num);
- } else if (IS_TMP_VAR == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
- Z_ADDREF_P(expr_ptr);
- }
- }
+ if (ARG_SHOULD_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
+ // TODO: Scalar values don't have reference counters anymore.
+ // They are assumed to be 1, and they may be easily passed by
+ // reference now. However, previously scalars with refcount==1
+ // might be passed and with refcount>1 might not. We can support
+ // only single behavior ???
+#if 0
+ if (Z_REFCOUNTED_P(arg) &&
+ // This solution breaks the following test (omit warning message) ???
+ // Zend/tests/bug61273.phpt
+ // ext/reflection/tests/bug42976.phpt
+ // ext/standard/tests/general_functions/call_user_func_array_variation_001.phpt
+#else
+ if (!Z_REFCOUNTED_P(arg) ||
+ // This solution breaks the following test (emit warning message) ???
+ // ext/pdo_sqlite/tests/pdo_005.phpt
+#endif
+ (!Z_ISREF_P(arg) /*&& Z_REFCOUNT_P(arg) > 1???*/)) {
- if (IS_CV != IS_UNUSED) {
+ if (!ARG_MAY_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
- zval *offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
- zend_string *str;
- zend_ulong hval;
+ zend_error(E_WARNING, "Parameter %d to %s%s%s() expected to be a reference, value given",
+ opline->op2.num,
+ EX(call)->func->common.scope ? EX(call)->func->common.scope->name->val : "",
+ EX(call)->func->common.scope ? "::" : "",
+ EX(call)->func->common.function_name->val);
-add_again:
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- goto num_index;
- case IS_LONG:
- hval = Z_LVAL_P(offset);
-num_index:
- zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
- break;
- case IS_STRING:
- str = Z_STR_P(offset);
- if (IS_CV != IS_CONST) {
- if (ZEND_HANDLE_NUMERIC(str, hval)) {
- goto num_index;
- }
+ if (EX(call)->func->common.fn_flags & ZEND_ACC_CLOSURE) {
+ OBJ_RELEASE((zend_object*)EX(call)->func->common.prototype);
}
-str_index:
- zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
- break;
- case IS_NULL:
- str = STR_EMPTY_ALLOC();
- goto str_index;
- case IS_FALSE:
- hval = 0;
- goto num_index;
- case IS_TRUE:
- hval = 1;
- goto num_index;
- case IS_REFERENCE:
- offset = Z_REFVAL_P(offset);
- goto add_again;
- break;
- default:
- zend_error(E_WARNING, "Illegal offset type");
- zval_ptr_dtor(expr_ptr);
- /* do nothing */
- break;
- }
+ if (Z_OBJ(EX(call)->This)) {
+ OBJ_RELEASE(Z_OBJ(EX(call)->This));
+ }
+ EX(call)->func = (zend_function*)&zend_pass_function;
+ EX(call)->called_scope = NULL;
+ Z_OBJ(EX(call)->This) = NULL;
+
+ zval_ptr_dtor_nogc(free_op1);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+ if (Z_REFCOUNTED_P(arg)) {
+ Z_DELREF_P(arg);
+ }
+ ZVAL_DUP(&tmp, arg);
+ ZVAL_NEW_REF(arg, &tmp);
+ Z_ADDREF_P(arg);
+ } else if (!Z_ISREF_P(arg)) {
+ ZVAL_NEW_REF(arg, arg);
+ Z_ADDREF_P(arg);
+ } else if (Z_REFCOUNTED_P(arg)) {
+ Z_ADDREF_P(arg);
+ }
+ ZVAL_COPY_VALUE(param, arg);
+ } else if (Z_ISREF_P(arg) &&
+ /* don't separate references for __call */
+ (EX(call)->func->common.fn_flags & ZEND_ACC_CALL_VIA_HANDLER) == 0) {
+ ZVAL_DUP(param, Z_REFVAL_P(arg));
} else {
- zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
+ ZVAL_COPY(param, arg);
}
+
+ ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
+
+ zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_NEW_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- zval *array;
- uint32_t size;
USE_OPLINE
+ zval object_zval;
+ zend_function *constructor;
+ zend_class_entry *ce;
- array = EX_VAR(opline->result.var);
- if (IS_TMP_VAR != IS_UNUSED) {
- size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
+ SAVE_OPLINE();
+ if (IS_VAR == IS_CONST) {
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv));
+ } else {
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op1.zv), opline->op1.zv + 1, 0 TSRMLS_CC);
+ if (UNEXPECTED(ce == NULL)) {
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op1.zv), ce);
+ }
} else {
- size = 0;
+ ce = Z_CE_P(EX_VAR(opline->op1.var));
}
- ZVAL_NEW_ARR(array);
- zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
-
- if (IS_TMP_VAR != IS_UNUSED) {
- /* Explicitly initialize array as not-packed if flag is set */
- if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
- zend_hash_real_init(Z_ARRVAL_P(array), 0);
+ if (UNEXPECTED((ce->ce_flags & (ZEND_ACC_INTERFACE|ZEND_ACC_IMPLICIT_ABSTRACT_CLASS|ZEND_ACC_EXPLICIT_ABSTRACT_CLASS)) != 0)) {
+ if (ce->ce_flags & ZEND_ACC_INTERFACE) {
+ zend_error_noreturn(E_ERROR, "Cannot instantiate interface %s", ce->name->val);
+ } else if ((ce->ce_flags & ZEND_ACC_TRAIT) == ZEND_ACC_TRAIT) {
+ zend_error_noreturn(E_ERROR, "Cannot instantiate trait %s", ce->name->val);
+ } else {
+ zend_error_noreturn(E_ERROR, "Cannot instantiate abstract class %s", ce->name->val);
}
}
+ object_init_ex(&object_zval, ce);
+ constructor = Z_OBJ_HT(object_zval)->get_constructor(Z_OBJ(object_zval) TSRMLS_CC);
- if (IS_TMP_VAR == IS_UNUSED) {
- ZEND_VM_NEXT_OPCODE();
-#if 0 || IS_TMP_VAR != IS_UNUSED
+ if (constructor == NULL) {
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), &object_zval);
+ } else {
+ OBJ_RELEASE(Z_OBJ(object_zval));
+ }
+ ZEND_VM_JMP(opline->op2.jmp_addr);
} else {
- return ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-#endif
+ /* We are not handling overloaded classes right now */
+ EX(call) = zend_vm_stack_push_call_frame(
+ ZEND_CALL_FUNCTION | ZEND_CALL_CTOR |
+ (RETURN_VALUE_USED(opline) ? 0 : ZEND_CALL_CTOR_RESULT_UNUSED),
+ constructor,
+ opline->extended_value,
+ ce,
+ Z_OBJ(object_zval),
+ EX(call) TSRMLS_CC);
+
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), &object_zval);
+ EX(call)->return_value = EX_VAR(opline->result.var);
+ } else {
+ EX(call)->return_value = NULL;
+ }
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_CLONE_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
- zval *container;
- int result;
- zend_ulong hval;
- zval *offset;
+ zval *obj;
+ zend_class_entry *ce;
+ zend_function *clone;
+ zend_object_clone_obj_t clone_call;
SAVE_OPLINE();
- container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
-
- if (IS_TMP_VAR != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
- HashTable *ht = Z_ARRVAL_P(container);
- zval *value;
- zend_string *str;
+ obj = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-isset_again:
- if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
- str = Z_STR_P(offset);
- if (IS_CV != IS_CONST) {
- if (ZEND_HANDLE_NUMERIC(str, hval)) {
- goto num_index_prop;
- }
- }
-str_index_prop:
- value = zend_hash_find_ind(ht, str);
- } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
- hval = Z_LVAL_P(offset);
-num_index_prop:
- value = zend_hash_index_find(ht, hval);
- } else {
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- goto num_index_prop;
- case IS_NULL:
- str = STR_EMPTY_ALLOC();
- goto str_index_prop;
- case IS_FALSE:
- hval = 0;
- goto num_index_prop;
- case IS_TRUE:
- hval = 1;
- goto num_index_prop;
- case IS_RESOURCE:
- hval = Z_RES_HANDLE_P(offset);
- goto num_index_prop;
- case IS_REFERENCE:
- offset = Z_REFVAL_P(offset);
- goto isset_again;
- default:
- zend_error(E_WARNING, "Illegal offset type in isset or empty");
- value = NULL;
- break;
- }
+ if (IS_VAR == IS_CONST ||
+ (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(obj) != IS_OBJECT))) {
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
}
+ zend_error_noreturn(E_ERROR, "__clone method called on non-object");
+ }
- if (opline->extended_value & ZEND_ISSET) {
- /* > IS_NULL means not IS_UNDEF and not IS_NULL */
- result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
- }
- } else if (IS_TMP_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
- result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
+ ce = Z_OBJCE_P(obj);
+ clone = ce ? ce->clone : NULL;
+ clone_call = Z_OBJ_HT_P(obj)->clone_obj;
+ if (UNEXPECTED(clone_call == NULL)) {
+ if (ce) {
+ zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object of class %s", ce->name->val);
} else {
- zend_error(E_NOTICE, "Trying to check element of non-array");
- result = 0;
- }
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
+ zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object");
}
- } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
- zval tmp;
+ }
- result = 0;
- if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
- if (IS_CV == IS_CV || IS_CV == IS_VAR) {
- ZVAL_DEREF(offset);
+ if (ce && clone) {
+ if (clone->op_array.fn_flags & ZEND_ACC_PRIVATE) {
+ /* Ensure that if we're calling a private function, we're allowed to do so.
+ */
+ if (UNEXPECTED(ce != EG(scope))) {
+ zend_error_noreturn(E_ERROR, "Call to private %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
}
- if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
- || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
- && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
- ZVAL_DUP(&tmp, offset);
- convert_to_long(&tmp);
- offset = &tmp;
+ } else if ((clone->common.fn_flags & ZEND_ACC_PROTECTED)) {
+ /* Ensure that if we're calling a protected function, we're allowed to do so.
+ */
+ if (UNEXPECTED(!zend_check_protected(zend_get_function_root_class(clone), EG(scope)))) {
+ zend_error_noreturn(E_ERROR, "Call to protected %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
}
}
- if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
- if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
- if ((opline->extended_value & ZEND_ISSET) ||
- Z_STRVAL_P(container)[offset->value.lval] != '0') {
- result = 1;
- }
- }
- }
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
- }
- } else {
- result = ((opline->extended_value & ZEND_ISSET) == 0);
}
- ZVAL_BOOL(EX_VAR(opline->result.var), result);
+ if (EXPECTED(EG(exception) == NULL)) {
+ ZVAL_OBJ(EX_VAR(opline->result.var), clone_call(obj TSRMLS_CC));
+ if (!RETURN_VALUE_USED(opline) || UNEXPECTED(EG(exception) != NULL)) {
+ OBJ_RELEASE(Z_OBJ_P(EX_VAR(opline->result.var)));
+ }
+ }
zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_CAST_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
- zval *container;
- int result;
- zval *offset;
+ zval *expr;
+ zval *result = EX_VAR(opline->result.var);
SAVE_OPLINE();
- container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ expr = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
- if (IS_TMP_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
- result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to check property of non-object");
- result = 0;
- }
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
- }
- } else {
- result = ((opline->extended_value & ZEND_ISSET) == 0);
+ switch (opline->extended_value) {
+ case IS_NULL:
+ /* This code is taken from convert_to_null. However, it does not seems very useful,
+ * because a conversion to null always results in the same value. This could only
+ * be relevant if a cast_object handler for IS_NULL has some kind of side-effect. */
+#if 0
+ if (IS_VAR == IS_VAR || IS_VAR == IS_CV) {
+ ZVAL_DEREF(expr);
+ }
+ if (Z_TYPE_P(expr) == IS_OBJECT && Z_OBJ_HT_P(expr)->cast_object) {
+ if (Z_OBJ_HT_P(expr)->cast_object(expr, result, IS_NULL TSRMLS_CC) == SUCCESS) {
+ break;
+ }
+ }
+#endif
+
+ ZVAL_NULL(result);
+ break;
+ case _IS_BOOL:
+ ZVAL_BOOL(result, zend_is_true(expr TSRMLS_CC));
+ break;
+ case IS_LONG:
+ ZVAL_LONG(result, zval_get_long(expr));
+ break;
+ case IS_DOUBLE:
+ ZVAL_DOUBLE(result, zval_get_double(expr));
+ break;
+ case IS_STRING:
+ ZVAL_STR(result, zval_get_string(expr));
+ break;
+ default:
+ /* If value is already of correct type, return it directly */
+ if (Z_TYPE_P(expr) == opline->extended_value) {
+ ZVAL_COPY_VALUE(result, expr);
+ if (IS_VAR == IS_CONST) {
+ if (UNEXPECTED(Z_OPT_COPYABLE_P(result))) {
+ zval_copy_ctor_func(result);
+ }
+ } else if (IS_VAR != IS_TMP_VAR) {
+ if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
+ }
+
+ zval_ptr_dtor_nogc(free_op1);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+
+ if (opline->extended_value == IS_ARRAY) {
+ if (Z_TYPE_P(expr) != IS_OBJECT) {
+ ZVAL_NEW_ARR(result);
+ zend_hash_init(Z_ARRVAL_P(result), 8, NULL, ZVAL_PTR_DTOR, 0);
+ if (Z_TYPE_P(expr) != IS_NULL) {
+ expr = zend_hash_index_add_new(Z_ARRVAL_P(result), 0, expr);
+ if (IS_VAR == IS_CONST) {
+ if (UNEXPECTED(Z_OPT_COPYABLE_P(expr))) {
+ zval_copy_ctor_func(expr);
+ }
+ } else {
+ if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
+ }
+ }
+ } else {
+ ZVAL_COPY_VALUE(result, expr);
+ Z_ADDREF_P(result);
+ convert_to_array(result);
+ }
+ } else {
+ if (Z_TYPE_P(expr) != IS_ARRAY) {
+ object_init(result);
+ if (Z_TYPE_P(expr) != IS_NULL) {
+ expr = zend_hash_str_add_new(Z_OBJPROP_P(result), "scalar", sizeof("scalar")-1, expr);
+ if (IS_VAR == IS_CONST) {
+ if (UNEXPECTED(Z_OPT_COPYABLE_P(expr))) {
+ zval_copy_ctor_func(expr);
+ }
+ } else {
+ if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
+ }
+ }
+ } else {
+ ZVAL_COPY_VALUE(result, expr);
+ zval_opt_copy_ctor(result);
+ convert_to_object(result);
+ }
+ }
}
- ZVAL_BOOL(EX_VAR(opline->result.var), result);
zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_YIELD_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FE_RESET_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zend_free_op free_op1;
+ zval *array_ptr, *array_ref, iterator, tmp;
+ HashTable *fe_ht;
+ zend_object_iterator *iter = NULL;
+ zend_class_entry *ce = NULL;
+ zend_bool is_empty = 0;
- /* The generator object is stored in EX(return_value) */
- zend_generator *generator = (zend_generator *) EX(return_value);
-
- if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
- zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
- }
-
- /* Destroy the previously yielded value */
- zval_ptr_dtor(&generator->value);
-
- /* Destroy the previously yielded key */
- zval_ptr_dtor(&generator->key);
-
- /* Set the new yielded value */
- if (IS_TMP_VAR != IS_UNUSED) {
- zend_free_op free_op1;
-
- if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
- /* Constants and temporary variables aren't yieldable by reference,
- * but we still allow them with a notice. */
- if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
- zval *value;
-
- zend_error(E_NOTICE, "Only variable references should be yielded by reference");
-
- value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
- ZVAL_COPY_VALUE(&generator->value, value);
- if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
-
- /* Temporary variables don't need ctor copying */
- if (IS_TMP_VAR != IS_TMP_VAR) {
- zval_opt_copy_ctor(&generator->value);
- }
- } else {
- zval *value_ptr = NULL;
+ SAVE_OPLINE();
- if (IS_TMP_VAR == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
+ if ((IS_VAR == IS_CV || IS_VAR == IS_VAR) &&
+ (opline->extended_value & ZEND_FE_FETCH_BYREF)) {
+ array_ptr = array_ref = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+ ZVAL_DEREF(array_ptr);
+ if (Z_TYPE_P(array_ptr) == IS_ARRAY) {
+ SEPARATE_ARRAY(array_ptr);
+ if (!Z_ISREF_P(array_ref)) {
+ ZVAL_NEW_REF(array_ref, array_ref);
+ array_ptr = Z_REFVAL_P(array_ref);
+ }
+ if (Z_REFCOUNTED_P(array_ref)) Z_ADDREF_P(array_ref);
+ } else if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
+ ce = Z_OBJCE_P(array_ptr);
+ if (ce->get_iterator == NULL) {
+ Z_ADDREF_P(array_ptr);
+ }
+ array_ref = array_ptr;
+ } else {
+ if (Z_REFCOUNTED_P(array_ref)) Z_ADDREF_P(array_ref);
+ }
+ } else {
+ array_ptr = array_ref = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+ ZVAL_DEREF(array_ptr);
+ if (IS_VAR == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&tmp, array_ptr);
+ if (Z_OPT_IMMUTABLE_P(&tmp)) {
+ zval_copy_ctor_func(&tmp);
+ }
+ array_ref = array_ptr = &tmp;
+ if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
+ ce = Z_OBJCE_P(array_ptr);
+ if (ce && ce->get_iterator) {
+ Z_DELREF_P(array_ref);
}
-
- /* If a function call result is yielded and the function did
- * not return by reference we throw a notice. */
- if (IS_TMP_VAR == IS_VAR &&
- (value_ptr == &EG(uninitialized_zval) ||
- (opline->extended_value == ZEND_RETURNS_FUNCTION &&
- !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
- zend_error(E_NOTICE, "Only variable references should be yielded by reference");
- } else {
- ZVAL_MAKE_REF(value_ptr);
+ }
+ } else if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
+ ce = Z_OBJCE_P(array_ptr);
+ if (!ce->get_iterator) {
+ if (IS_VAR == IS_CV) {
+ Z_ADDREF_P(array_ref);
}
- ZVAL_COPY(&generator->value, value_ptr);
-
}
- } else {
- zval *value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
- /* Consts, temporary variables and references need copying */
- if (IS_TMP_VAR == IS_CONST) {
- ZVAL_DUP(&generator->value, value);
- } else if (IS_TMP_VAR == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&generator->value, value);
- } else if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) && Z_ISREF_P(value)) {
- ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
-
+ } else if (Z_IMMUTABLE_P(array_ref)) {
+ if (IS_VAR == IS_CV) {
+ zval_copy_ctor_func(array_ref);
+ Z_ADDREF_P(array_ref);
} else {
- ZVAL_COPY_VALUE(&generator->value, value);
- if (IS_TMP_VAR == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+ ZVAL_COPY_VALUE(&tmp, array_ref);
+ zval_copy_ctor_func(&tmp);
+ array_ptr = array_ref = &tmp;
+ }
+ } else if (Z_REFCOUNTED_P(array_ref)) {
+ if (IS_VAR == IS_CONST ||
+ (IS_VAR == IS_CV &&
+ !Z_ISREF_P(array_ref) &&
+ Z_REFCOUNT_P(array_ref) > 1) ||
+ (IS_VAR == IS_VAR &&
+ !Z_ISREF_P(array_ref) &&
+ Z_REFCOUNT_P(array_ref) > 2)) {
+ if (IS_VAR == IS_VAR) {
+ Z_DELREF_P(array_ref);
+ }
+ ZVAL_DUP(&tmp, array_ref);
+ array_ptr = array_ref = &tmp;
+ } else if (IS_VAR == IS_CV || IS_VAR == IS_VAR) {
+ if (Z_ISREF_P(array_ref) && Z_REFCOUNT_P(array_ref) == 1) {
+ ZVAL_UNREF(array_ref);
+ array_ptr = array_ref;
+ }
+ if (Z_IMMUTABLE_P(array_ptr)) {
+ zval_copy_ctor_func(array_ptr);
+ } else if (Z_ISREF_P(array_ref) &&
+ Z_COPYABLE_P(array_ptr) &&
+ Z_REFCOUNT_P(array_ptr) > 1) {
+ Z_DELREF_P(array_ptr);
+ zval_copy_ctor_func(array_ptr);
+ }
+ if (IS_VAR == IS_CV) {
+ Z_ADDREF_P(array_ref);
}
}
}
- } else {
- /* If no value was specified yield null */
- ZVAL_NULL(&generator->value);
}
- /* Set the new yielded key */
- if (IS_CV != IS_UNUSED) {
-
- zval *key = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
-
- /* Consts, temporary variables and references need copying */
- if (IS_CV == IS_CONST) {
- ZVAL_DUP(&generator->key, key);
- } else if (IS_CV == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&generator->key, key);
- } else if ((IS_CV == IS_VAR || IS_CV == IS_CV) && Z_ISREF_P(key)) {
- ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
+ if (ce && ce->get_iterator) {
+ iter = ce->get_iterator(ce, array_ptr, opline->extended_value & ZEND_FE_FETCH_BYREF TSRMLS_CC);
+ if (IS_VAR == IS_VAR && !(opline->extended_value & ZEND_FE_FETCH_BYREF)) {
+ zval_ptr_dtor_nogc(free_op1);
+ }
+ if (iter && EXPECTED(EG(exception) == NULL)) {
+ ZVAL_OBJ(&iterator, &iter->std);
+ array_ptr = array_ref = &iterator;
} else {
- ZVAL_COPY_VALUE(&generator->key, key);
- if (IS_CV == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
+ if (IS_VAR == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
}
+ if (!EG(exception)) {
+ zend_throw_exception_ex(NULL, 0 TSRMLS_CC, "Object of type %s did not create an Iterator", ce->name->val);
+ }
+ zend_throw_exception_internal(NULL TSRMLS_CC);
+ HANDLE_EXCEPTION();
}
-
- if (Z_TYPE(generator->key) == IS_LONG
- && Z_LVAL(generator->key) > generator->largest_used_integer_key
- ) {
- generator->largest_used_integer_key = Z_LVAL(generator->key);
- }
- } else {
- /* If no key was specified we use auto-increment keys */
- generator->largest_used_integer_key++;
- ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
- }
-
- if (RETURN_VALUE_USED(opline)) {
- /* If the return value of yield is used set the send
- * target and initialize it to NULL */
- generator->send_target = EX_VAR(opline->result.var);
- ZVAL_NULL(generator->send_target);
- } else {
- generator->send_target = NULL;
}
- /* We increment to the next op, so we are at the correct position when the
- * generator is resumed. */
- ZEND_VM_INC_OPCODE();
-
- /* The GOTO VM uses a local opline variable. We need to set the opline
- * variable in execute_data so we don't resume at an old position. */
- SAVE_OPLINE();
-
- ZEND_VM_RETURN();
-}
-
-static int ZEND_FASTCALL ZEND_POW_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
-
- SAVE_OPLINE();
- pow_function(EX_VAR(opline->result.var),
- _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_BW_NOT_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
-
- SAVE_OPLINE();
- bitwise_not_function(EX_VAR(opline->result.var),
- _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_BOOL_NOT_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
-
- SAVE_OPLINE();
- boolean_not_function(EX_VAR(opline->result.var),
- _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_PRE_INC_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *var_ptr;
-
- SAVE_OPLINE();
- var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), array_ref);
- if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
+ if (iter) {
+ iter->index = 0;
+ if (iter->funcs->rewind) {
+ iter->funcs->rewind(iter TSRMLS_CC);
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ zval_ptr_dtor(array_ref);
+ if (IS_VAR == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+ }
+ HANDLE_EXCEPTION();
+ }
+ }
+ is_empty = iter->funcs->valid(iter TSRMLS_CC) != SUCCESS;
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ zval_ptr_dtor(array_ref);
+ if (IS_VAR == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+ }
+ HANDLE_EXCEPTION();
+ }
+ iter->index = -1; /* will be set to 0 before using next handler */
+ } else if ((fe_ht = HASH_OF(array_ptr)) != NULL) {
+ HashPointer *ptr = (HashPointer*)EX_VAR((opline+2)->op1.var);
+ HashPosition pos = 0;
+ Bucket *p;
- if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
- fast_increment_function(var_ptr);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
+ while (1) {
+ if (pos >= fe_ht->nNumUsed) {
+ is_empty = 1;
+ if (IS_VAR == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+ }
+ ZEND_VM_JMP(opline->op2.jmp_addr);
+ }
+ p = fe_ht->arData + pos;
+ if (Z_TYPE(p->val) == IS_UNDEF ||
+ (Z_TYPE(p->val) == IS_INDIRECT &&
+ Z_TYPE_P(Z_INDIRECT(p->val)) == IS_UNDEF)) {
+ pos++;
+ continue;
+ }
+ if (!ce ||
+ !p->key ||
+ zend_check_property_access(Z_OBJ_P(array_ptr), p->key TSRMLS_CC) == SUCCESS) {
+ break;
+ }
+ pos++;
}
- ZEND_VM_NEXT_OPCODE();
+ fe_ht->nInternalPointer = pos;
+ ptr->pos = pos;
+ ptr->ht = fe_ht;
+ ptr->h = fe_ht->arData[pos].h;
+ ptr->key = fe_ht->arData[pos].key;
+ is_empty = 0;
+ } else {
+ zend_error(E_WARNING, "Invalid argument supplied for foreach()");
+ is_empty = 1;
}
- if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
+ if (IS_VAR == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+ }
+ if (is_empty) {
+ ZEND_VM_JMP(opline->op2.jmp_addr);
+ } else {
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-
- ZVAL_DEREF(var_ptr);
- SEPARATE_ZVAL_NOREF(var_ptr);
-
- increment_function(var_ptr);
-
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
- }
-
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_PRE_DEC_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FE_FETCH_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *var_ptr;
- SAVE_OPLINE();
- var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
-
- if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
- fast_decrement_function(var_ptr);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
- }
- ZEND_VM_NEXT_OPCODE();
- }
+ zval *array, *array_ref;
+ zval *value;
+ HashTable *fe_ht;
+ HashPointer *ptr;
+ HashPosition pos;
+ Bucket *p;
- if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
+ array = array_ref = EX_VAR(opline->op1.var);
+ if (Z_ISREF_P(array)) {
+ array = Z_REFVAL_P(array);
+ // TODO: referenced value might be changed to different array ???
+ if (Z_IMMUTABLE_P(array)) {
+ zval_copy_ctor_func(array);
}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
}
- ZVAL_DEREF(var_ptr);
- SEPARATE_ZVAL_NOREF(var_ptr);
-
- decrement_function(var_ptr);
-
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
- }
+ SAVE_OPLINE();
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_POST_INC_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *var_ptr;
-
- SAVE_OPLINE();
- var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
-
- if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
- fast_increment_function(var_ptr);
- ZEND_VM_NEXT_OPCODE();
- }
-
- if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-
- ZVAL_DEREF(var_ptr);
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
- zval_opt_copy_ctor(var_ptr);
-
- increment_function(var_ptr);
-
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_POST_DEC_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *var_ptr;
-
- SAVE_OPLINE();
- var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
-
- if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
- fast_decrement_function(var_ptr);
- ZEND_VM_NEXT_OPCODE();
- }
-
- if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-
- ZVAL_DEREF(var_ptr);
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
- zval_opt_copy_ctor(var_ptr);
-
- decrement_function(var_ptr);
-
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_ECHO_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *z;
-
- SAVE_OPLINE();
- z = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
- zend_print_variable(z TSRMLS_CC);
-
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_PRINT_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- ZVAL_LONG(EX_VAR(opline->result.var), 1);
- return ZEND_ECHO_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_JMPZ_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *val;
-
- SAVE_OPLINE();
- val = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_TMP_VAR) {
- if (Z_TYPE_P(val) == IS_TRUE) {
- ZEND_VM_SET_OPCODE(opline + 1);
- ZEND_VM_CONTINUE();
- } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
- ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
- ZEND_VM_CONTINUE();
- }
- }
-
- if (i_zend_is_true(val TSRMLS_CC)) {
- opline++;
- } else {
- opline = opline->op2.jmp_addr;
- }
- zval_ptr_dtor_nogc(free_op1);
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- ZEND_VM_JMP(opline);
-}
-
-static int ZEND_FASTCALL ZEND_JMPNZ_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *val;
-
- SAVE_OPLINE();
- val = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_TMP_VAR) {
- if (Z_TYPE_P(val) == IS_TRUE) {
- ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
- ZEND_VM_CONTINUE();
- } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
- ZEND_VM_SET_OPCODE(opline + 1);
- ZEND_VM_CONTINUE();
- }
- }
-
- if (i_zend_is_true(val TSRMLS_CC)) {
- opline = opline->op2.jmp_addr;
- } else {
- opline++;
- }
- zval_ptr_dtor_nogc(free_op1);
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- ZEND_VM_JMP(opline);
-}
-
-static int ZEND_FASTCALL ZEND_JMPZNZ_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *val;
-
- SAVE_OPLINE();
- val = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_TMP_VAR) {
- if (EXPECTED(Z_TYPE_P(val) == IS_TRUE)) {
- ZEND_VM_SET_RELATIVE_OPCODE(opline, opline->extended_value);
- ZEND_VM_CONTINUE();
- } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
- ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
- ZEND_VM_CONTINUE();
- }
- }
-
- if (i_zend_is_true(val TSRMLS_CC)) {
- opline = (zend_op*)(((char*)opline) + opline->extended_value);
- } else {
- opline = opline->op2.jmp_addr;
- }
- zval_ptr_dtor_nogc(free_op1);
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- ZEND_VM_JMP(opline);
-}
-
-static int ZEND_FASTCALL ZEND_JMPZ_EX_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *val;
-
- SAVE_OPLINE();
- val = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_TMP_VAR) {
- if (Z_TYPE_P(val) == IS_TRUE) {
- ZVAL_TRUE(EX_VAR(opline->result.var));
- ZEND_VM_SET_OPCODE(opline + 1);
- ZEND_VM_CONTINUE();
- } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
- ZVAL_FALSE(EX_VAR(opline->result.var));
- ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
- ZEND_VM_CONTINUE();
- }
- }
-
- if (i_zend_is_true(val TSRMLS_CC)) {
- zval_ptr_dtor_nogc(free_op1);
- ZVAL_TRUE(EX_VAR(opline->result.var));
- opline++;
- } else {
- zval_ptr_dtor_nogc(free_op1);
- ZVAL_FALSE(EX_VAR(opline->result.var));
- opline = opline->op2.jmp_addr;
- }
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- ZEND_VM_JMP(opline);
-}
-
-static int ZEND_FASTCALL ZEND_JMPNZ_EX_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *val;
-
- SAVE_OPLINE();
- val = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_TMP_VAR) {
- if (Z_TYPE_P(val) == IS_TRUE) {
- ZVAL_TRUE(EX_VAR(opline->result.var));
- ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
- ZEND_VM_CONTINUE();
- } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
- ZVAL_FALSE(EX_VAR(opline->result.var));
- ZEND_VM_SET_OPCODE(opline + 1);
- ZEND_VM_CONTINUE();
- }
- }
- if (i_zend_is_true(val TSRMLS_CC)) {
- ZVAL_TRUE(EX_VAR(opline->result.var));
- opline = opline->op2.jmp_addr;
- } else {
- ZVAL_FALSE(EX_VAR(opline->result.var));
- opline++;
- }
- zval_ptr_dtor_nogc(free_op1);
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- ZEND_VM_JMP(opline);
-}
-
-static int ZEND_FASTCALL ZEND_RETURN_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *retval_ptr;
- zend_free_op free_op1;
-
- SAVE_OPLINE();
- retval_ptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if (!EX(return_value)) {
- zval_ptr_dtor_nogc(free_op1);
- } else {
- if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
- if (IS_VAR == IS_CONST) {
- if (UNEXPECTED(Z_OPT_COPYABLE_P(EX(return_value)))) {
- zval_copy_ctor_func(EX(return_value));
- }
- }
- } else if ((IS_VAR == IS_CV || IS_VAR == IS_VAR) && Z_ISREF_P(retval_ptr)) {
- ZVAL_COPY(EX(return_value), Z_REFVAL_P(retval_ptr));
- zval_ptr_dtor_nogc(free_op1);
- } else {
- ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
- if (IS_VAR == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(retval_ptr)) Z_ADDREF_P(retval_ptr);
- }
- }
- }
- return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_RETURN_BY_REF_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *retval_ptr;
- zend_free_op free_op1;
-
- SAVE_OPLINE();
-
- do {
- if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR ||
- (IS_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_VALUE)) {
- /* Not supposed to happen, but we'll allow it */
- zend_error(E_NOTICE, "Only variable references should be returned by reference");
-
- retval_ptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (!EX(return_value)) {
- if (IS_VAR == IS_TMP_VAR) {
- zval_ptr_dtor_nogc(free_op1);
- }
- } else {
- ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
- Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
- if (IS_VAR != IS_TMP_VAR) {
- zval_opt_copy_ctor_no_imm(EX(return_value));
- }
- }
- break;
- }
-
- retval_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_VAR && UNEXPECTED(retval_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot return string offsets by reference");
- }
-
- if (IS_VAR == IS_VAR) {
- if (retval_ptr == &EG(uninitialized_zval) ||
- (opline->extended_value == ZEND_RETURNS_FUNCTION &&
- !(Z_VAR_FLAGS_P(retval_ptr) & IS_VAR_RET_REF))) {
- zend_error(E_NOTICE, "Only variable references should be returned by reference");
- if (EX(return_value)) {
- ZVAL_NEW_REF(EX(return_value), retval_ptr);
- Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
- if (Z_REFCOUNTED_P(retval_ptr)) Z_ADDREF_P(retval_ptr);
- }
- break;
- }
- }
-
- if (EX(return_value)) {
- ZVAL_MAKE_REF(retval_ptr);
- Z_ADDREF_P(retval_ptr);
- ZVAL_REF(EX(return_value), Z_REF_P(retval_ptr));
- Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
- }
- } while (0);
-
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_THROW_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *value;
- zend_free_op free_op1;
-
- SAVE_OPLINE();
- value = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_CONST || UNEXPECTED(Z_TYPE_P(value) != IS_OBJECT)) {
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- zend_error_noreturn(E_ERROR, "Can only throw objects");
- }
-
- zend_exception_save(TSRMLS_C);
- if (IS_VAR != IS_TMP_VAR) {
- if (Z_REFCOUNTED_P(value)) Z_ADDREF_P(value);
- }
-
- zend_throw_exception_object(value TSRMLS_CC);
- zend_exception_restore(TSRMLS_C);
- zval_ptr_dtor_nogc(free_op1);
- HANDLE_EXCEPTION();
-}
-
-static int ZEND_FASTCALL ZEND_SEND_VAR_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *varptr, *arg;
- zend_free_op free_op1;
-
- varptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
- ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
- if ((IS_VAR == IS_CV || IS_VAR == IS_VAR) && Z_ISREF_P(varptr)) {
- ZVAL_COPY(arg, Z_REFVAL_P(varptr));
- zval_ptr_dtor_nogc(free_op1);
- } else {
- ZVAL_COPY_VALUE(arg, varptr);
- if (IS_VAR == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(arg)) Z_ADDREF_P(arg);
- }
- }
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_SEND_VAR_NO_REF_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *varptr, *arg;
-
- SAVE_OPLINE();
-
- if (!(opline->extended_value & ZEND_ARG_COMPILE_TIME_BOUND)) {
- if (!ARG_SHOULD_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
- return ZEND_SEND_VAR_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
- }
-
- varptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- if ((!(opline->extended_value & ZEND_ARG_SEND_FUNCTION) ||
- (Z_VAR_FLAGS_P(varptr) & IS_VAR_RET_REF)) &&
- (Z_ISREF_P(varptr) || Z_TYPE_P(varptr) == IS_OBJECT)) {
-
- ZVAL_MAKE_REF(varptr);
- if (IS_VAR == IS_CV) {
- Z_ADDREF_P(varptr);
- }
- } else {
- if ((opline->extended_value & ZEND_ARG_COMPILE_TIME_BOUND) ?
- !(opline->extended_value & ZEND_ARG_SEND_SILENT) :
- !ARG_MAY_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
- zend_error(E_STRICT, "Only variables should be passed by reference");
- }
- }
-
- arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
- ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
- ZVAL_COPY_VALUE(arg, varptr);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_SEND_REF_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *varptr, *arg;
-
- SAVE_OPLINE();
- varptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_VAR && UNEXPECTED(varptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Only variables can be passed by reference");
- }
-
- arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
- ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
- if (IS_VAR == IS_VAR && UNEXPECTED(varptr == &EG(error_zval))) {
- ZVAL_NEW_REF(arg, &EG(uninitialized_zval));
- ZEND_VM_NEXT_OPCODE();
- }
-
- if (Z_ISREF_P(varptr)) {
- Z_ADDREF_P(varptr);
- ZVAL_COPY_VALUE(arg, varptr);
- } else if (IS_VAR == IS_VAR &&
- UNEXPECTED(Z_TYPE_P(EX_VAR(opline->op1.var)) != IS_INDIRECT)) {
- ZVAL_NEW_REF(arg, varptr);
- } else {
- ZVAL_NEW_REF(arg, varptr);
- Z_ADDREF_P(arg);
- ZVAL_REF(varptr, Z_REF_P(arg));
- }
-
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_SEND_VAR_EX_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *varptr, *arg;
- zend_free_op free_op1;
-
- if (ARG_SHOULD_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
- return ZEND_SEND_REF_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
- varptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
- ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
- if ((IS_VAR == IS_CV || IS_VAR == IS_VAR) && Z_ISREF_P(varptr)) {
- ZVAL_COPY(arg, Z_REFVAL_P(varptr));
- zval_ptr_dtor_nogc(free_op1);
- } else {
- ZVAL_COPY_VALUE(arg, varptr);
- if (IS_VAR == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(arg)) Z_ADDREF_P(arg);
- }
- }
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_SEND_USER_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *arg, *param, tmp;
- zend_free_op free_op1;
-
- arg = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- param = ZEND_CALL_ARG(EX(call), opline->op2.num);
-
- if (ARG_SHOULD_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
- // TODO: Scalar values don't have reference counters anymore.
- // They are assumed to be 1, and they may be easily passed by
- // reference now. However, previously scalars with refcount==1
- // might be passed and with refcount>1 might not. We can support
- // only single behavior ???
-#if 0
- if (Z_REFCOUNTED_P(arg) &&
- // This solution breaks the following test (omit warning message) ???
- // Zend/tests/bug61273.phpt
- // ext/reflection/tests/bug42976.phpt
- // ext/standard/tests/general_functions/call_user_func_array_variation_001.phpt
-#else
- if (!Z_REFCOUNTED_P(arg) ||
- // This solution breaks the following test (emit warning message) ???
- // ext/pdo_sqlite/tests/pdo_005.phpt
-#endif
- (!Z_ISREF_P(arg) /*&& Z_REFCOUNT_P(arg) > 1???*/)) {
-
- if (!ARG_MAY_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
-
- zend_error(E_WARNING, "Parameter %d to %s%s%s() expected to be a reference, value given",
- opline->op2.num,
- EX(call)->func->common.scope ? EX(call)->func->common.scope->name->val : "",
- EX(call)->func->common.scope ? "::" : "",
- EX(call)->func->common.function_name->val);
-
- if (EX(call)->func->common.fn_flags & ZEND_ACC_CLOSURE) {
- OBJ_RELEASE((zend_object*)EX(call)->func->common.prototype);
- }
- if (Z_OBJ(EX(call)->This)) {
- OBJ_RELEASE(Z_OBJ(EX(call)->This));
- }
- EX(call)->func = (zend_function*)&zend_pass_function;
- EX(call)->called_scope = NULL;
- Z_OBJ(EX(call)->This) = NULL;
-
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-
- if (Z_REFCOUNTED_P(arg)) {
- Z_DELREF_P(arg);
- }
- ZVAL_DUP(&tmp, arg);
- ZVAL_NEW_REF(arg, &tmp);
- Z_ADDREF_P(arg);
- } else if (!Z_ISREF_P(arg)) {
- ZVAL_NEW_REF(arg, arg);
- Z_ADDREF_P(arg);
- } else if (Z_REFCOUNTED_P(arg)) {
- Z_ADDREF_P(arg);
- }
- ZVAL_COPY_VALUE(param, arg);
- } else if (Z_ISREF_P(arg) &&
- /* don't separate references for __call */
- (EX(call)->func->common.fn_flags & ZEND_ACC_CALL_VIA_HANDLER) == 0) {
- ZVAL_DUP(param, Z_REFVAL_P(arg));
- } else {
- ZVAL_COPY(param, arg);
- }
-
- ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
-
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_BOOL_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *retval = EX_VAR(opline->result.var);
-
- SAVE_OPLINE();
- /* PHP 3.0 returned "" for false and 1 for true, here we use 0 and 1 for now */
- ZVAL_BOOL(retval, i_zend_is_true(_get_zval_ptr_var(opline->op1.var, execute_data, &free_op1) TSRMLS_CC));
- zval_ptr_dtor_nogc(free_op1);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_NEW_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval object_zval;
- zend_function *constructor;
- zend_class_entry *ce;
-
- SAVE_OPLINE();
- if (IS_VAR == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op1.zv), opline->op1.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op1.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op1.var));
- }
- if (UNEXPECTED((ce->ce_flags & (ZEND_ACC_INTERFACE|ZEND_ACC_IMPLICIT_ABSTRACT_CLASS|ZEND_ACC_EXPLICIT_ABSTRACT_CLASS)) != 0)) {
- if (ce->ce_flags & ZEND_ACC_INTERFACE) {
- zend_error_noreturn(E_ERROR, "Cannot instantiate interface %s", ce->name->val);
- } else if ((ce->ce_flags & ZEND_ACC_TRAIT) == ZEND_ACC_TRAIT) {
- zend_error_noreturn(E_ERROR, "Cannot instantiate trait %s", ce->name->val);
- } else {
- zend_error_noreturn(E_ERROR, "Cannot instantiate abstract class %s", ce->name->val);
- }
- }
- object_init_ex(&object_zval, ce);
- constructor = Z_OBJ_HT(object_zval)->get_constructor(Z_OBJ(object_zval) TSRMLS_CC);
-
- if (constructor == NULL) {
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), &object_zval);
- } else {
- OBJ_RELEASE(Z_OBJ(object_zval));
- }
- ZEND_VM_JMP(opline->op2.jmp_addr);
- } else {
- /* We are not handling overloaded classes right now */
- EX(call) = zend_vm_stack_push_call_frame(
- ZEND_CALL_FUNCTION | ZEND_CALL_CTOR |
- (RETURN_VALUE_USED(opline) ? 0 : ZEND_CALL_CTOR_RESULT_UNUSED),
- constructor,
- opline->extended_value,
- ce,
- Z_OBJ(object_zval),
- EX(call) TSRMLS_CC);
-
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), &object_zval);
- EX(call)->return_value = EX_VAR(opline->result.var);
- } else {
- EX(call)->return_value = NULL;
- }
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-}
-
-static int ZEND_FASTCALL ZEND_CLONE_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *obj;
- zend_class_entry *ce;
- zend_function *clone;
- zend_object_clone_obj_t clone_call;
-
- SAVE_OPLINE();
- obj = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_CONST ||
- (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(obj) != IS_OBJECT))) {
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- zend_error_noreturn(E_ERROR, "__clone method called on non-object");
- }
-
- ce = Z_OBJCE_P(obj);
- clone = ce ? ce->clone : NULL;
- clone_call = Z_OBJ_HT_P(obj)->clone_obj;
- if (UNEXPECTED(clone_call == NULL)) {
- if (ce) {
- zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object of class %s", ce->name->val);
- } else {
- zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object");
- }
- }
-
- if (ce && clone) {
- if (clone->op_array.fn_flags & ZEND_ACC_PRIVATE) {
- /* Ensure that if we're calling a private function, we're allowed to do so.
- */
- if (UNEXPECTED(ce != EG(scope))) {
- zend_error_noreturn(E_ERROR, "Call to private %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
- }
- } else if ((clone->common.fn_flags & ZEND_ACC_PROTECTED)) {
- /* Ensure that if we're calling a protected function, we're allowed to do so.
- */
- if (UNEXPECTED(!zend_check_protected(zend_get_function_root_class(clone), EG(scope)))) {
- zend_error_noreturn(E_ERROR, "Call to protected %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
- }
- }
- }
-
- if (EXPECTED(EG(exception) == NULL)) {
- ZVAL_OBJ(EX_VAR(opline->result.var), clone_call(obj TSRMLS_CC));
- if (!RETURN_VALUE_USED(opline) || UNEXPECTED(EG(exception) != NULL)) {
- OBJ_RELEASE(Z_OBJ_P(EX_VAR(opline->result.var)));
- }
- }
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_CAST_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *expr;
- zval *result = EX_VAR(opline->result.var);
-
- SAVE_OPLINE();
- expr = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
- switch (opline->extended_value) {
- case IS_NULL:
- /* This code is taken from convert_to_null. However, it does not seems very useful,
- * because a conversion to null always results in the same value. This could only
- * be relevant if a cast_object handler for IS_NULL has some kind of side-effect. */
-#if 0
- if (IS_VAR == IS_VAR || IS_VAR == IS_CV) {
- ZVAL_DEREF(expr);
- }
- if (Z_TYPE_P(expr) == IS_OBJECT && Z_OBJ_HT_P(expr)->cast_object) {
- if (Z_OBJ_HT_P(expr)->cast_object(expr, result, IS_NULL TSRMLS_CC) == SUCCESS) {
- break;
- }
- }
-#endif
-
- ZVAL_NULL(result);
- break;
- case _IS_BOOL:
- ZVAL_BOOL(result, zend_is_true(expr TSRMLS_CC));
- break;
- case IS_LONG:
- ZVAL_LONG(result, zval_get_long(expr));
- break;
- case IS_DOUBLE:
- ZVAL_DOUBLE(result, zval_get_double(expr));
- break;
- case IS_STRING:
- ZVAL_STR(result, zval_get_string(expr));
- break;
- default:
- /* If value is already of correct type, return it directly */
- if (Z_TYPE_P(expr) == opline->extended_value) {
- ZVAL_COPY_VALUE(result, expr);
- if (IS_VAR == IS_CONST) {
- if (UNEXPECTED(Z_OPT_COPYABLE_P(result))) {
- zval_copy_ctor_func(result);
- }
- } else if (IS_VAR != IS_TMP_VAR) {
- if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
- }
-
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-
- if (opline->extended_value == IS_ARRAY) {
- if (Z_TYPE_P(expr) != IS_OBJECT) {
- ZVAL_NEW_ARR(result);
- zend_hash_init(Z_ARRVAL_P(result), 8, NULL, ZVAL_PTR_DTOR, 0);
- if (Z_TYPE_P(expr) != IS_NULL) {
- expr = zend_hash_index_add_new(Z_ARRVAL_P(result), 0, expr);
- if (IS_VAR == IS_CONST) {
- if (UNEXPECTED(Z_OPT_COPYABLE_P(expr))) {
- zval_copy_ctor_func(expr);
- }
- } else {
- if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
- }
- }
- } else {
- ZVAL_COPY_VALUE(result, expr);
- Z_ADDREF_P(result);
- convert_to_array(result);
- }
- } else {
- if (Z_TYPE_P(expr) != IS_ARRAY) {
- object_init(result);
- if (Z_TYPE_P(expr) != IS_NULL) {
- expr = zend_hash_str_add_new(Z_OBJPROP_P(result), "scalar", sizeof("scalar")-1, expr);
- if (IS_VAR == IS_CONST) {
- if (UNEXPECTED(Z_OPT_COPYABLE_P(expr))) {
- zval_copy_ctor_func(expr);
- }
- } else {
- if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
- }
- }
- } else {
- ZVAL_COPY_VALUE(result, expr);
- zval_opt_copy_ctor(result);
- convert_to_object(result);
- }
- }
- }
-
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_INCLUDE_OR_EVAL_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_op_array *new_op_array=NULL;
- zend_free_op free_op1;
- zval *inc_filename;
- zval tmp_inc_filename;
- zend_bool failure_retval=0;
-
- SAVE_OPLINE();
- inc_filename = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- ZVAL_UNDEF(&tmp_inc_filename);
- if (Z_TYPE_P(inc_filename) != IS_STRING) {
- ZVAL_STR(&tmp_inc_filename, zval_get_string(inc_filename));
- inc_filename = &tmp_inc_filename;
- }
-
- if (opline->extended_value != ZEND_EVAL && strlen(Z_STRVAL_P(inc_filename)) != Z_STRLEN_P(inc_filename)) {
- if (opline->extended_value == ZEND_INCLUDE_ONCE || opline->extended_value == ZEND_INCLUDE) {
- zend_message_dispatcher(ZMSG_FAILED_INCLUDE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
- } else {
- zend_message_dispatcher(ZMSG_FAILED_REQUIRE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
- }
- } else {
- switch (opline->extended_value) {
- case ZEND_INCLUDE_ONCE:
- case ZEND_REQUIRE_ONCE: {
- zend_file_handle file_handle;
- char *resolved_path;
-
- resolved_path = zend_resolve_path(Z_STRVAL_P(inc_filename), (int)Z_STRLEN_P(inc_filename) TSRMLS_CC);
- if (resolved_path) {
- failure_retval = zend_hash_str_exists(&EG(included_files), resolved_path, (int)strlen(resolved_path));
- } else {
- resolved_path = Z_STRVAL_P(inc_filename);
- }
-
- if (failure_retval) {
- /* do nothing, file already included */
- } else if (SUCCESS == zend_stream_open(resolved_path, &file_handle TSRMLS_CC)) {
-
- if (!file_handle.opened_path) {
- file_handle.opened_path = estrdup(resolved_path);
- }
-
- if (zend_hash_str_add_empty_element(&EG(included_files), file_handle.opened_path, (int)strlen(file_handle.opened_path))) {
- new_op_array = zend_compile_file(&file_handle, (opline->extended_value==ZEND_INCLUDE_ONCE?ZEND_INCLUDE:ZEND_REQUIRE) TSRMLS_CC);
- zend_destroy_file_handle(&file_handle TSRMLS_CC);
- } else {
- zend_file_handle_dtor(&file_handle TSRMLS_CC);
- failure_retval=1;
- }
- } else {
- if (opline->extended_value == ZEND_INCLUDE_ONCE) {
- zend_message_dispatcher(ZMSG_FAILED_INCLUDE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
- } else {
- zend_message_dispatcher(ZMSG_FAILED_REQUIRE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
- }
- }
- if (resolved_path != Z_STRVAL_P(inc_filename)) {
- efree(resolved_path);
- }
- }
- break;
- case ZEND_INCLUDE:
- case ZEND_REQUIRE:
- new_op_array = compile_filename(opline->extended_value, inc_filename TSRMLS_CC);
- break;
- case ZEND_EVAL: {
- char *eval_desc = zend_make_compiled_string_description("eval()'d code" TSRMLS_CC);
-
- new_op_array = zend_compile_string(inc_filename, eval_desc TSRMLS_CC);
- efree(eval_desc);
- }
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
- }
- }
- if (Z_TYPE(tmp_inc_filename) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp_inc_filename));
- }
- zval_ptr_dtor_nogc(free_op1);
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- } else if (EXPECTED(new_op_array != NULL)) {
- zval *return_value = NULL;
- zend_execute_data *call;
-
- if (RETURN_VALUE_USED(opline)) {
- return_value = EX_VAR(opline->result.var);
- }
-
- new_op_array->scope = EG(scope); /* ??? */
-
- call = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_CODE,
- (zend_function*)new_op_array, 0, EX(called_scope), Z_OBJ(EX(This)), NULL TSRMLS_CC);
-
- if (EX(symbol_table)) {
- call->symbol_table = EX(symbol_table);
- } else {
- call->symbol_table = zend_rebuild_symbol_table(TSRMLS_C);
- }
-
- call->prev_execute_data = execute_data;
- i_init_code_execute_data(call, new_op_array, return_value TSRMLS_CC);
- if (EXPECTED(zend_execute_ex == execute_ex)) {
- ZEND_VM_ENTER();
- } else {
- ZEND_ADD_CALL_FLAG(call, ZEND_CALL_TOP);
- zend_execute_ex(call TSRMLS_CC);
- }
-
- destroy_op_array(new_op_array TSRMLS_CC);
- efree_size(new_op_array, sizeof(zend_op_array));
- if (UNEXPECTED(EG(exception) != NULL)) {
- zend_throw_exception_internal(NULL TSRMLS_CC);
- HANDLE_EXCEPTION();
- }
-
- } else if (RETURN_VALUE_USED(opline)) {
- ZVAL_BOOL(EX_VAR(opline->result.var), failure_retval);
- }
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FE_RESET_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *array_ptr, *array_ref, iterator, tmp;
- HashTable *fe_ht;
- zend_object_iterator *iter = NULL;
- zend_class_entry *ce = NULL;
- zend_bool is_empty = 0;
-
- SAVE_OPLINE();
-
- if ((IS_VAR == IS_CV || IS_VAR == IS_VAR) &&
- (opline->extended_value & ZEND_FE_FETCH_BYREF)) {
- array_ptr = array_ref = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- ZVAL_DEREF(array_ptr);
- if (Z_TYPE_P(array_ptr) == IS_ARRAY) {
- SEPARATE_ARRAY(array_ptr);
- if (!Z_ISREF_P(array_ref)) {
- ZVAL_NEW_REF(array_ref, array_ref);
- array_ptr = Z_REFVAL_P(array_ref);
- }
- if (Z_REFCOUNTED_P(array_ref)) Z_ADDREF_P(array_ref);
- } else if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
- ce = Z_OBJCE_P(array_ptr);
- if (ce->get_iterator == NULL) {
- Z_ADDREF_P(array_ptr);
- }
- array_ref = array_ptr;
- } else {
- if (Z_REFCOUNTED_P(array_ref)) Z_ADDREF_P(array_ref);
- }
- } else {
- array_ptr = array_ref = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- ZVAL_DEREF(array_ptr);
- if (IS_VAR == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&tmp, array_ptr);
- if (Z_OPT_IMMUTABLE_P(&tmp)) {
- zval_copy_ctor_func(&tmp);
- }
- array_ref = array_ptr = &tmp;
- if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
- ce = Z_OBJCE_P(array_ptr);
- if (ce && ce->get_iterator) {
- Z_DELREF_P(array_ref);
- }
- }
- } else if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
- ce = Z_OBJCE_P(array_ptr);
- if (!ce->get_iterator) {
- if (IS_VAR == IS_CV) {
- Z_ADDREF_P(array_ref);
- }
- }
- } else if (Z_IMMUTABLE_P(array_ref)) {
- if (IS_VAR == IS_CV) {
- zval_copy_ctor_func(array_ref);
- Z_ADDREF_P(array_ref);
- } else {
- ZVAL_COPY_VALUE(&tmp, array_ref);
- zval_copy_ctor_func(&tmp);
- array_ptr = array_ref = &tmp;
- }
- } else if (Z_REFCOUNTED_P(array_ref)) {
- if (IS_VAR == IS_CONST ||
- (IS_VAR == IS_CV &&
- !Z_ISREF_P(array_ref) &&
- Z_REFCOUNT_P(array_ref) > 1) ||
- (IS_VAR == IS_VAR &&
- !Z_ISREF_P(array_ref) &&
- Z_REFCOUNT_P(array_ref) > 2)) {
- if (IS_VAR == IS_VAR) {
- Z_DELREF_P(array_ref);
- }
- ZVAL_DUP(&tmp, array_ref);
- array_ptr = array_ref = &tmp;
- } else if (IS_VAR == IS_CV || IS_VAR == IS_VAR) {
- if (Z_ISREF_P(array_ref) && Z_REFCOUNT_P(array_ref) == 1) {
- ZVAL_UNREF(array_ref);
- array_ptr = array_ref;
- }
- if (Z_IMMUTABLE_P(array_ptr)) {
- zval_copy_ctor_func(array_ptr);
- } else if (Z_ISREF_P(array_ref) &&
- Z_COPYABLE_P(array_ptr) &&
- Z_REFCOUNT_P(array_ptr) > 1) {
- Z_DELREF_P(array_ptr);
- zval_copy_ctor_func(array_ptr);
- }
- if (IS_VAR == IS_CV) {
- Z_ADDREF_P(array_ref);
- }
- }
- }
- }
-
- if (ce && ce->get_iterator) {
- iter = ce->get_iterator(ce, array_ptr, opline->extended_value & ZEND_FE_FETCH_BYREF TSRMLS_CC);
-
- if (IS_VAR == IS_VAR && !(opline->extended_value & ZEND_FE_FETCH_BYREF)) {
- zval_ptr_dtor_nogc(free_op1);
- }
- if (iter && EXPECTED(EG(exception) == NULL)) {
- ZVAL_OBJ(&iterator, &iter->std);
- array_ptr = array_ref = &iterator;
- } else {
- if (IS_VAR == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- }
- if (!EG(exception)) {
- zend_throw_exception_ex(NULL, 0 TSRMLS_CC, "Object of type %s did not create an Iterator", ce->name->val);
- }
- zend_throw_exception_internal(NULL TSRMLS_CC);
- HANDLE_EXCEPTION();
- }
- }
-
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), array_ref);
-
- if (iter) {
- iter->index = 0;
- if (iter->funcs->rewind) {
- iter->funcs->rewind(iter TSRMLS_CC);
- if (UNEXPECTED(EG(exception) != NULL)) {
- zval_ptr_dtor(array_ref);
- if (IS_VAR == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- }
- HANDLE_EXCEPTION();
- }
- }
- is_empty = iter->funcs->valid(iter TSRMLS_CC) != SUCCESS;
- if (UNEXPECTED(EG(exception) != NULL)) {
- zval_ptr_dtor(array_ref);
- if (IS_VAR == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- }
- HANDLE_EXCEPTION();
- }
- iter->index = -1; /* will be set to 0 before using next handler */
- } else if ((fe_ht = HASH_OF(array_ptr)) != NULL) {
- HashPointer *ptr = (HashPointer*)EX_VAR((opline+2)->op1.var);
- HashPosition pos = 0;
- Bucket *p;
-
- while (1) {
- if (pos >= fe_ht->nNumUsed) {
- is_empty = 1;
- if (IS_VAR == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- }
- ZEND_VM_JMP(opline->op2.jmp_addr);
- }
- p = fe_ht->arData + pos;
- if (Z_TYPE(p->val) == IS_UNDEF ||
- (Z_TYPE(p->val) == IS_INDIRECT &&
- Z_TYPE_P(Z_INDIRECT(p->val)) == IS_UNDEF)) {
- pos++;
- continue;
- }
- if (!ce ||
- !p->key ||
- zend_check_property_access(Z_OBJ_P(array_ptr), p->key TSRMLS_CC) == SUCCESS) {
- break;
- }
- pos++;
- }
- fe_ht->nInternalPointer = pos;
- ptr->pos = pos;
- ptr->ht = fe_ht;
- ptr->h = fe_ht->arData[pos].h;
- ptr->key = fe_ht->arData[pos].key;
- is_empty = 0;
- } else {
- zend_error(E_WARNING, "Invalid argument supplied for foreach()");
- is_empty = 1;
- }
-
- if (IS_VAR == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- }
- if (is_empty) {
- ZEND_VM_JMP(opline->op2.jmp_addr);
- } else {
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-}
-
-static int ZEND_FASTCALL ZEND_FE_FETCH_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- zval *array, *array_ref;
- zval *value;
- HashTable *fe_ht;
- HashPointer *ptr;
- HashPosition pos;
- Bucket *p;
-
- array = array_ref = EX_VAR(opline->op1.var);
- if (Z_ISREF_P(array)) {
- array = Z_REFVAL_P(array);
- // TODO: referenced value might be changed to different array ???
- if (Z_IMMUTABLE_P(array)) {
- zval_copy_ctor_func(array);
- }
- }
-
- SAVE_OPLINE();
-
- if (EXPECTED(Z_TYPE_P(array) == IS_ARRAY)) {
- fe_ht = Z_ARRVAL_P(array);
- ptr = (HashPointer*)EX_VAR((opline+1)->op1.var);
- pos = ptr->pos;
- if (UNEXPECTED(pos == INVALID_IDX)) {
- /* reached end of iteration */
- ZEND_VM_JMP(opline->op2.jmp_addr);
- } else if (UNEXPECTED(ptr->ht != fe_ht)) {
- ptr->ht = fe_ht;
- pos = 0;
- } else if (UNEXPECTED(fe_ht->nInternalPointer != ptr->pos)) {
- if (fe_ht->u.flags & HASH_FLAG_PACKED) {
- pos = ptr->h;
- } else {
- pos = fe_ht->arHash[ptr->h & fe_ht->nTableMask];
- while (1) {
- if (pos == INVALID_IDX) {
- pos = fe_ht->nInternalPointer;
- break;
- } else if (fe_ht->arData[pos].h == ptr->h && fe_ht->arData[pos].key == ptr->key) {
- break;
- }
- pos = Z_NEXT(fe_ht->arData[pos].val);
- }
- }
- }
- while (1) {
- if (UNEXPECTED(pos >= fe_ht->nNumUsed)) {
- /* reached end of iteration */
- ZEND_VM_JMP(opline->op2.jmp_addr);
- }
- p = fe_ht->arData + pos;
- value = &p->val;
- if (UNEXPECTED(Z_TYPE_P(value) == IS_UNDEF)) {
- pos++;
- continue;
- } else if (UNEXPECTED(Z_TYPE_P(value) == IS_INDIRECT)) {
- value = Z_INDIRECT_P(value);
- if (UNEXPECTED(Z_TYPE_P(value) == IS_UNDEF)) {
- pos++;
- continue;
- }
- }
- if (opline->extended_value & ZEND_FE_FETCH_BYREF) {
- ZVAL_MAKE_REF(value);
- Z_ADDREF_P(value);
- ZVAL_REF(EX_VAR(opline->result.var), Z_REF_P(value));
- } else {
- ZVAL_COPY(EX_VAR(opline->result.var), value);
- }
- if (opline->extended_value & ZEND_FE_FETCH_WITH_KEY) {
- if (!p->key) {
- ZVAL_LONG(EX_VAR((opline+1)->result.var), p->h);
- } else {
- ZVAL_STR_COPY(EX_VAR((opline+1)->result.var), p->key);
- }
- }
- break;
- }
- do {
- pos++;
- if (pos >= fe_ht->nNumUsed) {
- fe_ht->nInternalPointer = ptr->pos = INVALID_IDX;
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
- }
- p = fe_ht->arData + pos;
- } while (Z_TYPE(p->val) == IS_UNDEF ||
- (Z_TYPE(p->val) == IS_INDIRECT &&
- Z_TYPE_P(Z_INDIRECT(p->val)) == IS_UNDEF));
- fe_ht->nInternalPointer = ptr->pos = pos;
- ptr->h = fe_ht->arData[pos].h;
- ptr->key = fe_ht->arData[pos].key;
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
- } else if (EXPECTED(Z_TYPE_P(array) == IS_OBJECT)) {
- zend_object_iterator *iter;
-
- if ((iter = zend_iterator_unwrap(array TSRMLS_CC)) == NULL) {
- /* plain object */
- zend_object *zobj = Z_OBJ_P(array);
-
- fe_ht = Z_OBJPROP_P(array);
- ptr = (HashPointer*)EX_VAR((opline+1)->op1.var);
- pos = ptr->pos;
- if (pos == INVALID_IDX) {
- /* reached end of iteration */
- ZEND_VM_JMP(opline->op2.jmp_addr);
- } else if (UNEXPECTED(ptr->ht != fe_ht)) {
- ptr->ht = fe_ht;
- pos = 0;
- } else if (UNEXPECTED(fe_ht->nInternalPointer != ptr->pos)) {
- if (fe_ht->u.flags & HASH_FLAG_PACKED) {
- pos = ptr->h;
- } else {
- pos = fe_ht->arHash[ptr->h & fe_ht->nTableMask];
- while (1) {
- if (pos == INVALID_IDX) {
- pos = fe_ht->nInternalPointer;
- break;
- } else if (fe_ht->arData[pos].h == ptr->h && fe_ht->arData[pos].key == ptr->key) {
- break;
- }
- pos = Z_NEXT(fe_ht->arData[pos].val);
- }
- }
- }
- while (1) {
- if (UNEXPECTED(pos >= fe_ht->nNumUsed)) {
- /* reached end of iteration */
- ZEND_VM_JMP(opline->op2.jmp_addr);
- }
-
- p = fe_ht->arData + pos;
- value = &p->val;
- if (UNEXPECTED(Z_TYPE_P(value) == IS_UNDEF)) {
- pos++;
- continue;
- } else if (UNEXPECTED(Z_TYPE_P(value) == IS_INDIRECT)) {
- value = Z_INDIRECT_P(value);
- if (UNEXPECTED(Z_TYPE_P(value) == IS_UNDEF)) {
- pos++;
- continue;
- }
- }
-
- if (UNEXPECTED(!p->key)) {
- if (opline->extended_value & ZEND_FE_FETCH_WITH_KEY) {
- ZVAL_LONG(EX_VAR((opline+1)->result.var), p->h);
- }
- break;
- } else if (zend_check_property_access(zobj, p->key TSRMLS_CC) == SUCCESS) {
- if (opline->extended_value & ZEND_FE_FETCH_WITH_KEY) {
- if (p->key->val[0]) {
- ZVAL_STR_COPY(EX_VAR((opline+1)->result.var), p->key);
- } else {
- const char *class_name, *prop_name;
- size_t prop_name_len;
- zend_unmangle_property_name_ex(
- p->key, &class_name, &prop_name, &prop_name_len);
- ZVAL_STRINGL(EX_VAR((opline+1)->result.var), prop_name, prop_name_len);
- }
- }
- break;
- }
- pos++;
- }
- if (opline->extended_value & ZEND_FE_FETCH_BYREF) {
- ZVAL_MAKE_REF(value);
- Z_ADDREF_P(value);
- ZVAL_REF(EX_VAR(opline->result.var), Z_REF_P(value));
- } else {
- ZVAL_COPY(EX_VAR(opline->result.var), value);
- }
- do {
- pos++;
- if (pos >= fe_ht->nNumUsed) {
- fe_ht->nInternalPointer = ptr->pos = INVALID_IDX;
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
- }
- p = fe_ht->arData + pos;
- } while (Z_TYPE(p->val) == IS_UNDEF ||
- (Z_TYPE(p->val) == IS_INDIRECT &&
- Z_TYPE_P(Z_INDIRECT(p->val)) == IS_UNDEF) ||
- (EXPECTED(p->key != NULL) &&
- zend_check_property_access(zobj, p->key TSRMLS_CC) == FAILURE));
- fe_ht->nInternalPointer = ptr->pos = pos;
- ptr->h = fe_ht->arData[pos].h;
- ptr->key = fe_ht->arData[pos].key;
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
- } else {
- /* !iter happens from exception */
- if (iter && ++iter->index > 0) {
- /* This could cause an endless loop if index becomes zero again.
- * In case that ever happens we need an additional flag. */
- iter->funcs->move_forward(iter TSRMLS_CC);
- if (UNEXPECTED(EG(exception) != NULL)) {
- zval_ptr_dtor(array_ref);
- HANDLE_EXCEPTION();
- }
- }
- /* If index is zero we come from FE_RESET and checked valid() already. */
- if (!iter || (iter->index > 0 && iter->funcs->valid(iter TSRMLS_CC) == FAILURE)) {
- /* reached end of iteration */
- if (UNEXPECTED(EG(exception) != NULL)) {
- zval_ptr_dtor(array_ref);
- HANDLE_EXCEPTION();
- }
- ZEND_VM_JMP(opline->op2.jmp_addr);
- }
- value = iter->funcs->get_current_data(iter TSRMLS_CC);
- if (UNEXPECTED(EG(exception) != NULL)) {
- zval_ptr_dtor(array_ref);
- HANDLE_EXCEPTION();
- }
- if (!value) {
- /* failure in get_current_data */
- ZEND_VM_JMP(opline->op2.jmp_addr);
- }
- if (opline->extended_value & ZEND_FE_FETCH_BYREF) {
- ZVAL_MAKE_REF(value);
- Z_ADDREF_P(value);
- ZVAL_REF(EX_VAR(opline->result.var), Z_REF_P(value));
- } else {
- ZVAL_COPY(EX_VAR(opline->result.var), value);
- }
- if (opline->extended_value & ZEND_FE_FETCH_WITH_KEY) {
- if (iter->funcs->get_current_key) {
- iter->funcs->get_current_key(iter, EX_VAR((opline+1)->result.var) TSRMLS_CC);
- if (UNEXPECTED(EG(exception) != NULL)) {
- zval_ptr_dtor(array_ref);
- HANDLE_EXCEPTION();
- }
- } else {
- ZVAL_LONG(EX_VAR((opline+1)->result.var), iter->index);
- }
- }
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
- }
- } else {
- zend_error(E_WARNING, "Invalid argument supplied for foreach()");
- ZEND_VM_JMP(opline->op2.jmp_addr);
- }
-}
-
-static int ZEND_FASTCALL ZEND_EXIT_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-#if 0 || (IS_VAR != IS_UNUSED)
- USE_OPLINE
-
- SAVE_OPLINE();
- if (IS_VAR != IS_UNUSED) {
- zend_free_op free_op1;
- zval *ptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if (Z_TYPE_P(ptr) == IS_LONG) {
- EG(exit_status) = Z_LVAL_P(ptr);
- } else {
- zend_print_variable(ptr TSRMLS_CC);
- }
- zval_ptr_dtor_nogc(free_op1);
- }
-#endif
- zend_bailout();
- ZEND_VM_NEXT_OPCODE(); /* Never reached */
-}
-
-static int ZEND_FASTCALL ZEND_JMP_SET_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *value;
- int is_ref = 0;
-
- SAVE_OPLINE();
- value = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && Z_ISREF_P(value)) {
- is_ref = 1;
- value = Z_REFVAL_P(value);
- }
- if (i_zend_is_true(value TSRMLS_CC)) {
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), value);
- if (IS_VAR == IS_CONST) {
- if (UNEXPECTED(Z_OPT_COPYABLE_P(value))) {
- zval_copy_ctor_func(EX_VAR(opline->result.var));
- }
- } else if (IS_VAR == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
- } else if (IS_VAR == IS_VAR && is_ref) {
- if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
- zval_ptr_dtor_nogc(free_op1);
- }
- ZEND_VM_JMP(opline->op2.jmp_addr);
- }
-
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_COALESCE_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *value;
- int is_ref = 0;
-
- SAVE_OPLINE();
- value = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && Z_ISREF_P(value)) {
- is_ref = 1;
- value = Z_REFVAL_P(value);
- }
-
- if (Z_TYPE_P(value) > IS_NULL) {
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), value);
- if (IS_VAR == IS_CONST) {
- if (UNEXPECTED(Z_OPT_COPYABLE_P(value))) {
- zval_copy_ctor_func(EX_VAR(opline->result.var));
- }
- } else if (IS_VAR == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
- } else if (IS_VAR == IS_VAR && is_ref) {
- if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
- zval_ptr_dtor_nogc(free_op1);
- }
- ZEND_VM_JMP(opline->op2.jmp_addr);
- }
-
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_QM_ASSIGN_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *value;
-
- SAVE_OPLINE();
- value = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && Z_ISREF_P(value)) {
- ZVAL_COPY(EX_VAR(opline->result.var), Z_REFVAL_P(value));
- zval_ptr_dtor_nogc(free_op1);
- } else {
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), value);
- if (IS_VAR == IS_CONST) {
- if (UNEXPECTED(Z_OPT_COPYABLE_P(value))) {
- zval_copy_ctor_func(EX_VAR(opline->result.var));
- }
- } else if (IS_VAR == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
- }
- }
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_STRLEN_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *value;
- zend_free_op free_op1;
-
- SAVE_OPLINE();
- value = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
- if (EXPECTED(Z_TYPE_P(value) == IS_STRING)) {
- ZVAL_LONG(EX_VAR(opline->result.var), Z_STRLEN_P(value));
- } else {
- if (Z_TYPE_P(value) < IS_TRUE) {
- ZVAL_LONG(EX_VAR(opline->result.var), 0);
- } else if (Z_TYPE_P(value) == IS_TRUE) {
- ZVAL_LONG(EX_VAR(opline->result.var), 1);
- } else if (Z_TYPE_P(value) <= IS_DOUBLE) {
- zend_string *str = zval_get_string(value);
- ZVAL_LONG(EX_VAR(opline->result.var), str->len);
- zend_string_release(str);
- } else if (Z_TYPE_P(value) == IS_OBJECT) {
- zend_string *str;
- zval tmp;
-
- ZVAL_COPY(&tmp, value);
- if (parse_arg_object_to_str(&tmp, &str, IS_STRING TSRMLS_CC) == FAILURE) {
- goto strlen_error;
- }
- ZVAL_LONG(EX_VAR(opline->result.var), str->len);
- zval_dtor(&tmp);
- } else {
-strlen_error:
- zend_error(E_WARNING, "strlen() expects parameter 1 to be string, %s given", zend_get_type_by_const(Z_TYPE_P(value)));
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- }
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_TYPE_CHECK_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *value;
- zend_free_op free_op1;
-
- SAVE_OPLINE();
- value = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
- switch (opline->extended_value) {
- case IS_NULL:
- case IS_LONG:
- case IS_DOUBLE:
- case IS_STRING:
- case IS_ARRAY:
- ZVAL_BOOL(EX_VAR(opline->result.var), Z_TYPE_P(value) == opline->extended_value);
- break;
- case _IS_BOOL:
- ZVAL_BOOL(EX_VAR(opline->result.var), Z_TYPE_P(value) == IS_TRUE || Z_TYPE_P(value) == IS_FALSE);
- break;
- case IS_OBJECT:
- if (Z_TYPE_P(value) == opline->extended_value) {
- zend_class_entry *ce = Z_OBJCE_P(value);
- if (ce->name->len == sizeof("__PHP_Incomplete_Class") - 1
- && !strncmp(ce->name->val, "__PHP_Incomplete_Class", ce->name->len)) {
- ZVAL_FALSE(EX_VAR(opline->result.var));
- } else {
- ZVAL_TRUE(EX_VAR(opline->result.var));
- }
- } else {
- ZVAL_FALSE(EX_VAR(opline->result.var));
- }
- break;
- case IS_RESOURCE:
- if (Z_TYPE_P(value) == opline->extended_value) {
- const char *type_name = zend_rsrc_list_get_rsrc_type(Z_RES_P(value) TSRMLS_CC);
- ZVAL_BOOL(EX_VAR(opline->result.var), type_name != NULL);
- } else {
- ZVAL_FALSE(EX_VAR(opline->result.var));
- }
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
- }
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_MOD_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
-
- SAVE_OPLINE();
- fast_mod_function(EX_VAR(opline->result.var),
- _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- opline->op2.zv TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_SL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
-
- SAVE_OPLINE();
- shift_left_function(EX_VAR(opline->result.var),
- _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- opline->op2.zv TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_SR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
-
- SAVE_OPLINE();
- shift_right_function(EX_VAR(opline->result.var),
- _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- opline->op2.zv TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_CONCAT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
-
- SAVE_OPLINE();
- concat_function(EX_VAR(opline->result.var),
- _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- opline->op2.zv TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_IS_IDENTICAL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
-
- SAVE_OPLINE();
- fast_is_identical_function(EX_VAR(opline->result.var),
- _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- opline->op2.zv TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_IS_NOT_IDENTICAL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *result = EX_VAR(opline->result.var);
-
- SAVE_OPLINE();
- fast_is_not_identical_function(result,
- _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- opline->op2.zv TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_BW_OR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
-
- SAVE_OPLINE();
- bitwise_or_function(EX_VAR(opline->result.var),
- _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- opline->op2.zv TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_BW_AND_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
-
- SAVE_OPLINE();
- bitwise_and_function(EX_VAR(opline->result.var),
- _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- opline->op2.zv TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_BW_XOR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
-
- SAVE_OPLINE();
- bitwise_xor_function(EX_VAR(opline->result.var),
- _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- opline->op2.zv TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_BOOL_XOR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
-
- SAVE_OPLINE();
- boolean_xor_function(EX_VAR(opline->result.var),
- _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- opline->op2.zv TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1, free_op_data1;
- zval *object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- zval *property = opline->op2.zv;
- zval *value;
- zval *zptr;
-
- if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
-
- if (IS_VAR != IS_UNUSED) {
- object = make_real_object(object TSRMLS_CC);
- }
-
- value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-
- if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to assign property of non-object");
-
- FREE_OP(free_op_data1);
-
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- } else {
- /* here we are sure we are dealing with an object */
- if (opline->extended_value == ZEND_ASSIGN_OBJ
- && EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
-
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
-
- binary_op(zptr, zptr, value TSRMLS_CC);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), zptr);
- }
- } else {
- zval *z = NULL;
- zval rv;
-
- if (opline->extended_value == ZEND_ASSIGN_OBJ) {
- if (Z_OBJ_HT_P(object)->read_property) {
- z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
- }
- } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
- if (Z_OBJ_HT_P(object)->read_dimension) {
- z = Z_OBJ_HT_P(object)->read_dimension(object, property, BP_VAR_R, &rv TSRMLS_CC);
- }
- }
- if (z) {
- if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
- zval rv;
- zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
-
- if (Z_REFCOUNT_P(z) == 0) {
- zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
- }
- ZVAL_COPY_VALUE(z, value);
- }
-//??? if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
- SEPARATE_ZVAL_IF_NOT_REF(z);
- binary_op(z, z, value TSRMLS_CC);
- if (opline->extended_value == ZEND_ASSIGN_OBJ) {
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
- } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
- Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
- }
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), z);
- }
- zval_ptr_dtor(z);
- } else {
- zend_error(E_WARNING, "Attempt to assign property of non-object");
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- }
- }
-
- FREE_OP(free_op_data1);
- }
-
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- /* assign_obj has two opcodes! */
- CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1, free_op_data1;
- zval *var_ptr, rv;
- zval *value, *container;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- if (IS_VAR != IS_UNUSED) {
- ZVAL_DEREF(container);
- }
- if (IS_VAR == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (IS_VAR == IS_VAR && !(free_op1 != NULL)) {
- Z_ADDREF_P(container); /* undo the effect of get_obj_zval_ptr_ptr() */
- }
- return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else {
- zval *dim = opline->op2.zv;
-
- zend_fetch_dimension_address_RW(&rv, container, dim, IS_CONST TSRMLS_CC);
- value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
- var_ptr = Z_INDIRECT(rv);
- }
-
- if (UNEXPECTED(var_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
- }
-
- if (UNEXPECTED(var_ptr == &EG(error_zval))) {
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- } else {
- ZVAL_DEREF(var_ptr);
- SEPARATE_ZVAL_NOREF(var_ptr);
-
- binary_op(var_ptr, var_ptr, value TSRMLS_CC);
-
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
- }
- }
-
- FREE_OP(free_op_data1);
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *var_ptr;
- zval *value;
-
- SAVE_OPLINE();
- value = opline->op2.zv;
- var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
- }
-
- if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- } else {
- ZVAL_DEREF(var_ptr);
- SEPARATE_ZVAL_NOREF(var_ptr);
-
- binary_op(var_ptr, var_ptr, value TSRMLS_CC);
-
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
- }
- }
-
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *object;
- zval *property;
- zval *retval;
- zval *zptr;
-
- SAVE_OPLINE();
- object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- property = opline->op2.zv;
- retval = EX_VAR(opline->result.var);
-
- if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
-
- if (IS_VAR != IS_UNUSED) {
- object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
- }
-
- if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(retval);
- }
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-
- /* here we are sure we are dealing with an object */
-
- if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
-
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
-
- incdec_op(zptr);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(retval, zptr);
- }
- } else {
- zval rv;
-
- if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
-
- if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
- zval rv;
- zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
-
- if (Z_REFCOUNT_P(z) == 0) {
- zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
- }
- ZVAL_COPY_VALUE(z, value);
- }
- if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
- SEPARATE_ZVAL_IF_NOT_REF(z);
- incdec_op(z);
- ZVAL_COPY_VALUE(retval, z);
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
- SELECTIVE_PZVAL_LOCK(retval, opline);
- zval_ptr_dtor(z);
- } else {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(retval);
- }
- }
- }
-
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_pre_incdec_property_helper_SPEC_VAR_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_pre_incdec_property_helper_SPEC_VAR_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *object;
- zval *property;
- zval *retval;
- zval *zptr;
-
- SAVE_OPLINE();
- object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- property = opline->op2.zv;
- retval = EX_VAR(opline->result.var);
-
- if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
-
- if (IS_VAR != IS_UNUSED) {
- object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
- }
-
- if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-
- ZVAL_NULL(retval);
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-
- /* here we are sure we are dealing with an object */
-
- if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
-
- ZVAL_DEREF(zptr);
- ZVAL_COPY_VALUE(retval, zptr);
- zval_opt_copy_ctor(zptr);
-
- incdec_op(zptr);
- } else {
- if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval rv;
- zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
- zval z_copy;
-
- if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
- zval rv;
- zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
-
- if (Z_REFCOUNT_P(z) == 0) {
- zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
- }
- ZVAL_COPY_VALUE(z, value);
- }
- ZVAL_DUP(retval, z);
- ZVAL_DUP(&z_copy, z);
- incdec_op(&z_copy);
- if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
- Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
- zval_ptr_dtor(&z_copy);
- zval_ptr_dtor(z);
- } else {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- ZVAL_NULL(retval);
- }
- }
-
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_post_incdec_property_helper_SPEC_VAR_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_post_incdec_property_helper_SPEC_VAR_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_VAR_CONST(int type, ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *varname;
- zval *retval;
- zend_string *name;
- HashTable *target_symbol_table;
-
- SAVE_OPLINE();
- varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_CONST) {
- name = Z_STR_P(varname);
- } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
- name = Z_STR_P(varname);
- zend_string_addref(name);
- } else {
- name = zval_get_string(varname);
- }
-
- if (IS_CONST != IS_UNUSED) {
- zend_class_entry *ce;
-
- if (IS_CONST == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- if (IS_VAR != IS_CONST) {
- zend_string_release(name);
- }
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
- }
- retval = zend_std_get_static_property(ce, name, 0, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
- } else {
- target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- retval = zend_hash_find(target_symbol_table, name);
- if (retval == NULL) {
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_UNSET:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_IS:
- retval = &EG(uninitialized_zval);
- break;
- case BP_VAR_RW:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_W:
- retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
- }
- /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
- } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
- retval = Z_INDIRECT_P(retval);
- if (Z_TYPE_P(retval) == IS_UNDEF) {
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_UNSET:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_IS:
- retval = &EG(uninitialized_zval);
- break;
- case BP_VAR_RW:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_W:
- ZVAL_NULL(retval);
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
- }
- }
- }
- if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
- if (Z_CONSTANT_P(retval)) {
- zval_update_constant(retval, 1 TSRMLS_CC);
- }
- } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
- zval_ptr_dtor_nogc(free_op1);
- }
- }
-
- if (IS_VAR != IS_CONST) {
- zend_string_release(name);
- }
-
- ZEND_ASSERT(retval != NULL);
- if (type == BP_VAR_R || type == BP_VAR_IS) {
- if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
- ZVAL_UNREF(retval);
- }
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- } else {
- ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_R_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_VAR_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_W_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_VAR_CONST(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_RW_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_VAR_CONST(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_FUNC_ARG_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- return zend_fetch_var_address_helper_SPEC_VAR_CONST(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else {
- return zend_fetch_var_address_helper_SPEC_VAR_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_UNSET_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_VAR_CONST(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_IS_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_VAR_CONST(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *container;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
-
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_DIM_W_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *container;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
-
- if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_DIM_RW_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *container;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
-
- if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_DIM_IS_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *container;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
-
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *container;
- zend_free_op free_op1;
-
- SAVE_OPLINE();
-
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
- zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
- }
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
- if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
-
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- } else {
- if (IS_CONST == IS_UNUSED) {
- zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
- }
- container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
-
- zval_ptr_dtor_nogc(free_op1);
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_DIM_UNSET_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *container;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
-
- if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *container;
-
- zval *offset;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
- offset = opline->op2.zv;
-
- if ((IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
- UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
- zend_error(E_NOTICE, "Trying to get property of non-object");
- ZVAL_NULL(EX_VAR(opline->result.var));
- } else {
- zval *retval;
-
- /* here we are sure we are dealing with an object */
- do {
- if (IS_CONST == IS_CONST &&
- EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
- zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
- zend_object *zobj = Z_OBJ_P(container);
-
- if (EXPECTED(prop_info)) {
- retval = OBJ_PROP(zobj, prop_info->offset);
- if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- } else if (EXPECTED(zobj->properties != NULL)) {
- retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
- if (EXPECTED(retval)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- }
- }
-
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
-
- if (retval != EX_VAR(opline->result.var)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- }
- } while (0);
- }
-
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_W_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *property;
- zval *container;
-
- SAVE_OPLINE();
- property = opline->op2.zv;
-
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
-
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
-
- if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_RW_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *property;
- zval *container;
-
- SAVE_OPLINE();
- property = opline->op2.zv;
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
-
- if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *container;
-
- zval *offset;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
- offset = opline->op2.zv;
-
- if ((IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
- UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- } else {
- zval *retval;
-
- /* here we are sure we are dealing with an object */
- do {
- if (IS_CONST == IS_CONST &&
- EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
- zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
- zend_object *zobj = Z_OBJ_P(container);
-
- if (EXPECTED(prop_info)) {
- retval = OBJ_PROP(zobj, prop_info->offset);
- if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- } else if (EXPECTED(zobj->properties != NULL)) {
- retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
- if (EXPECTED(retval)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- }
- }
-
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
-
- if (retval != EX_VAR(opline->result.var)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- }
- } while (0);
- }
-
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *container;
-
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- /* Behave like FETCH_OBJ_W */
- zend_free_op free_op1;
- zval *property;
-
- SAVE_OPLINE();
- property = opline->op2.zv;
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
- zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
- }
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
-
- if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- } else {
- return ZEND_FETCH_OBJ_R_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_UNSET_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *container, *property;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- property = opline->op2.zv;
-
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
-
- if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_LIST_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *container;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
- if (EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
-
- zval *value = zend_fetch_dimension_address_inner(Z_ARRVAL_P(container), opline->op2.zv, IS_CONST, BP_VAR_R TSRMLS_CC);
-
- ZVAL_COPY(EX_VAR(opline->result.var), value);
- } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT) &&
- EXPECTED(Z_OBJ_HT_P(container)->read_dimension)) {
- zval *result = EX_VAR(opline->result.var);
- zval *retval = Z_OBJ_HT_P(container)->read_dimension(container, opline->op2.zv, BP_VAR_R, result TSRMLS_CC);
-
- if (retval) {
- if (result != retval) {
- ZVAL_COPY(result, retval);
- }
- } else {
- ZVAL_NULL(result);
- }
- } else {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *object;
- zval *property_name;
-
- SAVE_OPLINE();
- object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- property_name = opline->op2.zv;
-
- if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_VAR, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
-
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- /* assign_obj has two opcodes! */
- CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_DIM_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *object_ptr;
-
- SAVE_OPLINE();
- object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(object_ptr);
- if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
-
- zval *property_name = opline->op2.zv;
-
- zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_VAR, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
-
- } else {
- zend_free_op free_op_data1;
- zval rv;
- zval *value;
- zval *dim = opline->op2.zv;
- zval *variable_ptr;
-
- if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
- EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
- zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
-
- value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
- FREE_OP(free_op_data1);
- } else {
- zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_CONST TSRMLS_CC);
-
- value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
- variable_ptr = Z_INDIRECT(rv);
- if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
- FREE_OP(free_op_data1);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- } else {
- value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
- if ((opline+1)->op1_type == IS_VAR) {
- FREE_OP(free_op_data1);
- }
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), value);
- }
- }
- }
- }
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- /* assign_dim has two opcodes! */
- CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *value;
- zval *variable_ptr;
-
- SAVE_OPLINE();
- value = opline->op2.zv;
- variable_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
- if (IS_CONST == IS_TMP_VAR) {
-
- }
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- } else {
- value = zend_assign_to_variable(variable_ptr, value, IS_CONST TSRMLS_CC);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), value);
- }
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- }
-
- /* zend_assign_to_variable() always takes care of op2, never free it! */
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *function_name;
- zend_free_op free_op1;
- zval *object;
- zend_function *fbc;
- zend_class_entry *called_scope;
- zend_object *obj;
-
- SAVE_OPLINE();
-
- function_name = opline->op2.zv;
-
- if (IS_CONST != IS_CONST &&
- UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- zend_error_noreturn(E_ERROR, "Method name must be a string");
- }
-
- object = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- uint32_t nesting = 1;
-
- if (UNEXPECTED(EG(exception) != NULL)) {
-
- HANDLE_EXCEPTION();
- }
-
- zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s", Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
-
- zval_ptr_dtor_nogc(free_op1);
-
- if (EG(exception) != NULL) {
- HANDLE_EXCEPTION();
- }
-
- /* No exception raised: Skip over arguments until fcall opcode with correct
- * nesting level. Return NULL (except when return value unused) */
- do {
- opline++;
- if (opline->opcode == ZEND_INIT_FCALL ||
- opline->opcode == ZEND_INIT_FCALL_BY_NAME ||
- opline->opcode == ZEND_INIT_NS_FCALL_BY_NAME ||
- opline->opcode == ZEND_INIT_METHOD_CALL ||
- opline->opcode == ZEND_INIT_STATIC_METHOD_CALL ||
- opline->opcode == ZEND_INIT_USER_CALL ||
- opline->opcode == ZEND_NEW
- ) {
- nesting++;
- } else if (opline->opcode == ZEND_DO_FCALL) {
- nesting--;
- }
- } while (nesting);
-
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
-
- /* We've skipped EXT_FCALL_BEGIND, so also skip the ending opcode */
- if ((opline + 1)->opcode == ZEND_EXT_FCALL_END) {
- opline++;
- }
- ZEND_VM_JMP(++opline);
- }
-
- obj = Z_OBJ_P(object);
- called_scope = obj->ce;
-
- if (IS_CONST != IS_CONST ||
- EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
- zend_object *orig_obj = obj;
-
- if (UNEXPECTED(obj->handlers->get_method == NULL)) {
- zend_error_noreturn(E_ERROR, "Object does not support method calls");
- }
-
- /* First, locate the function. */
- fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_CONST == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
- if (UNEXPECTED(fbc == NULL)) {
- zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
- }
- if (IS_CONST == IS_CONST &&
- EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
- EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
- EXPECTED(obj == orig_obj)) {
- CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope, fbc);
- }
- }
-
- if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_STATIC) != 0)) {
- obj = NULL;
- } else {
- GC_REFCOUNT(obj)++; /* For $this pointer */
- }
-
- EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
- fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
-
- zval_ptr_dtor_nogc(free_op1);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *function_name;
- zend_class_entry *ce;
- zend_object *object;
- zend_function *fbc;
-
- SAVE_OPLINE();
-
- if (IS_VAR == IS_CONST) {
- /* no function found. try a static method in class */
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op1.zv), opline->op1.zv + 1, ZEND_FETCH_CLASS_DEFAULT TSRMLS_CC);
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- if (UNEXPECTED(ce == NULL)) {
- zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op1.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op1.var));
- }
-
- if (IS_VAR == IS_CONST &&
- IS_CONST == IS_CONST &&
- CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- fbc = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else if (IS_VAR != IS_CONST &&
- IS_CONST == IS_CONST &&
- (fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce))) {
- /* do nothing */
- } else if (IS_CONST != IS_UNUSED) {
-
-
- function_name = opline->op2.zv;
- if (IS_CONST != IS_CONST) {
- if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- zend_error_noreturn(E_ERROR, "Function name must be a string");
- }
- }
-
- if (ce->get_static_method) {
- fbc = ce->get_static_method(ce, Z_STR_P(function_name) TSRMLS_CC);
- } else {
- fbc = zend_std_get_static_method(ce, Z_STR_P(function_name), ((IS_CONST == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
- }
- if (UNEXPECTED(fbc == NULL)) {
- zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name->val, Z_STRVAL_P(function_name));
- }
- if (IS_CONST == IS_CONST &&
- EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
- EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0)) {
- if (IS_VAR == IS_CONST) {
- CACHE_PTR(Z_CACHE_SLOT_P(function_name), fbc);
- } else {
- CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), ce, fbc);
- }
- }
- if (IS_CONST != IS_CONST) {
-
- }
- } else {
- if (UNEXPECTED(ce->constructor == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot call constructor");
- }
- if (Z_OBJ(EX(This)) && Z_OBJ(EX(This))->ce != ce->constructor->common.scope && (ce->constructor->common.fn_flags & ZEND_ACC_PRIVATE)) {
- zend_error_noreturn(E_ERROR, "Cannot call private %s::__construct()", ce->name->val);
- }
- fbc = ce->constructor;
- }
-
- object = NULL;
- if (!(fbc->common.fn_flags & ZEND_ACC_STATIC)) {
- if (Z_OBJ(EX(This))) {
- object = Z_OBJ(EX(This));
- GC_REFCOUNT(object)++;
- }
- if (!object ||
- !instanceof_function(object->ce, ce TSRMLS_CC)) {
- /* We are calling method of the other (incompatible) class,
- but passing $this. This is done for compatibility with php-4. */
- if (fbc->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
- zend_error(
- object ? E_DEPRECATED : E_STRICT,
- "Non-static method %s::%s() should not be called statically%s",
- fbc->common.scope->name->val, fbc->common.function_name->val,
- object ? ", assuming $this from incompatible context" : "");
- } else {
- /* An internal function assumes $this is present and won't check that. So PHP would crash by allowing the call. */
- zend_error_noreturn(
- E_ERROR,
- "Non-static method %s::%s() cannot be called statically%s",
- fbc->common.scope->name->val, fbc->common.function_name->val,
- object ? ", assuming $this from incompatible context" : "");
- }
- }
- }
-
- if (IS_VAR != IS_CONST) {
- /* previous opcode is ZEND_FETCH_CLASS */
- if ((opline-1)->extended_value == ZEND_FETCH_CLASS_PARENT || (opline-1)->extended_value == ZEND_FETCH_CLASS_SELF) {
- ce = EX(called_scope);
- }
- }
-
- EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
- fbc, opline->extended_value, ce, object, EX(call) TSRMLS_CC);
-
- if (IS_CONST == IS_UNUSED) {
- EX(call)->return_value = NULL;
- }
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_CASE_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *result = EX_VAR(opline->result.var);
-
- SAVE_OPLINE();
- fast_equal_function(result,
- _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
- opline->op2.zv TSRMLS_CC);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_CONSTANT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- SAVE_OPLINE();
- if (IS_VAR == IS_UNUSED) {
- zend_constant *c;
- zval *retval;
-
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- c = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else if ((c = zend_quick_get_constant(opline->op2.zv + 1, opline->extended_value TSRMLS_CC)) == NULL) {
- if ((opline->extended_value & IS_CONSTANT_UNQUALIFIED) != 0) {
- char *actual = (char *)zend_memrchr(Z_STRVAL_P(opline->op2.zv), '\\', Z_STRLEN_P(opline->op2.zv));
- if (!actual) {
- ZVAL_STR(EX_VAR(opline->result.var), zend_string_copy(Z_STR_P(opline->op2.zv)));
- } else {
- actual++;
- ZVAL_STRINGL(EX_VAR(opline->result.var),
- actual, Z_STRLEN_P(opline->op2.zv) - (actual - Z_STRVAL_P(opline->op2.zv)));
- }
- /* non-qualified constant - allow text substitution */
- zend_error(E_NOTICE, "Use of undefined constant %s - assumed '%s'",
- Z_STRVAL_P(EX_VAR(opline->result.var)), Z_STRVAL_P(EX_VAR(opline->result.var)));
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- } else {
- zend_error_noreturn(E_ERROR, "Undefined constant '%s'", Z_STRVAL_P(opline->op2.zv));
- }
- } else {
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), c);
- }
- retval = EX_VAR(opline->result.var);
- ZVAL_COPY_VALUE(retval, &c->value);
- if (Z_OPT_COPYABLE_P(retval) || Z_OPT_REFCOUNTED_P(retval)) {
- if (Z_OPT_COPYABLE_P(retval)) {
- zval_copy_ctor_func(retval);
- } else {
- Z_ADDREF_P(retval);
- }
- }
- } else {
- /* class constant */
- zend_class_entry *ce;
- zval *value;
-
- if (IS_VAR == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- value = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- ZVAL_DEREF(value);
- ZVAL_DUP(EX_VAR(opline->result.var), value);
- goto constant_fetch_end;
- } else if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op1.zv), opline->op1.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- if (UNEXPECTED(ce == NULL)) {
- zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op1.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op1.var));
- if ((value = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce)) != NULL) {
- ZVAL_DEREF(value);
- ZVAL_DUP(EX_VAR(opline->result.var), value);
- goto constant_fetch_end;
- }
- }
-
- if (EXPECTED((value = zend_hash_find(&ce->constants_table, Z_STR_P(opline->op2.zv))) != NULL)) {
- ZVAL_DEREF(value);
- if (Z_CONSTANT_P(value)) {
- EG(scope) = ce;
- zval_update_constant(value, 1 TSRMLS_CC);
- EG(scope) = EX(func)->op_array.scope;
- }
- if (IS_VAR == IS_CONST) {
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), value);
- } else {
- CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce, value);
- }
- ZVAL_DUP(EX_VAR(opline->result.var), value);
- } else if (Z_STRLEN_P(opline->op2.zv) == sizeof("class")-1 && memcmp(Z_STRVAL_P(opline->op2.zv), "class", sizeof("class") - 1) == 0) {
- /* "class" is assigned as a case-sensitive keyword from zend_do_resolve_class_name */
- ZVAL_STR_COPY(EX_VAR(opline->result.var), ce->name);
- } else {
- zend_error_noreturn(E_ERROR, "Undefined class constant '%s'", Z_STRVAL_P(opline->op2.zv));
- }
- }
-constant_fetch_end:
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *expr_ptr, new_expr;
-
- SAVE_OPLINE();
- if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) &&
- (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
- expr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (IS_VAR == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
- }
- ZVAL_MAKE_REF(expr_ptr);
- Z_ADDREF_P(expr_ptr);
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- } else {
- expr_ptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (IS_VAR == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&new_expr, expr_ptr);
- expr_ptr = &new_expr;
- } else if (IS_VAR == IS_CONST) {
- if (!Z_IMMUTABLE_P(expr_ptr)) {
- ZVAL_DUP(&new_expr, expr_ptr);
- expr_ptr = &new_expr;
- }
- } else if ((IS_VAR == IS_CV || IS_VAR == IS_VAR) && Z_ISREF_P(expr_ptr)) {
- expr_ptr = Z_REFVAL_P(expr_ptr);
- if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
- zval_ptr_dtor_nogc(free_op1);
- } else if (IS_VAR == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
- Z_ADDREF_P(expr_ptr);
- }
- }
-
- if (IS_CONST != IS_UNUSED) {
-
- zval *offset = opline->op2.zv;
- zend_string *str;
- zend_ulong hval;
-
-add_again:
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- goto num_index;
- case IS_LONG:
- hval = Z_LVAL_P(offset);
-num_index:
- zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
- break;
- case IS_STRING:
- str = Z_STR_P(offset);
- if (IS_CONST != IS_CONST) {
- if (ZEND_HANDLE_NUMERIC(str, hval)) {
- goto num_index;
- }
- }
-str_index:
- zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
- break;
- case IS_NULL:
- str = STR_EMPTY_ALLOC();
- goto str_index;
- case IS_FALSE:
- hval = 0;
- goto num_index;
- case IS_TRUE:
- hval = 1;
- goto num_index;
- case IS_REFERENCE:
- offset = Z_REFVAL_P(offset);
- goto add_again;
- break;
- default:
- zend_error(E_WARNING, "Illegal offset type");
- zval_ptr_dtor(expr_ptr);
- /* do nothing */
- break;
- }
-
- } else {
- zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- zval *array;
- uint32_t size;
- USE_OPLINE
-
- array = EX_VAR(opline->result.var);
- if (IS_VAR != IS_UNUSED) {
- size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
- } else {
- size = 0;
- }
- ZVAL_NEW_ARR(array);
- zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
-
- if (IS_VAR != IS_UNUSED) {
- /* Explicitly initialize array as not-packed if flag is set */
- if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
- zend_hash_real_init(Z_ARRVAL_P(array), 0);
- }
- }
-
- if (IS_VAR == IS_UNUSED) {
- ZEND_VM_NEXT_OPCODE();
-#if 0 || IS_VAR != IS_UNUSED
- } else {
- return ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-#endif
- }
-}
-
-static int ZEND_FASTCALL ZEND_UNSET_VAR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval tmp, *varname;
- HashTable *target_symbol_table;
- zend_free_op free_op1;
-
- SAVE_OPLINE();
- if (IS_VAR == IS_CV &&
- IS_CONST == IS_UNUSED &&
- (opline->extended_value & ZEND_QUICK_SET)) {
- zval *var = EX_VAR(opline->op1.var);
-
- if (Z_REFCOUNTED_P(var)) {
- zend_refcounted *garbage = Z_COUNTED_P(var);
-
- if (!--GC_REFCOUNT(garbage)) {
- ZVAL_UNDEF(var);
- _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
- } else {
- GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
- ZVAL_UNDEF(var);
- }
- } else {
- ZVAL_UNDEF(var);
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-
- varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- ZVAL_UNDEF(&tmp);
- if (IS_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
- ZVAL_STR(&tmp, zval_get_string(varname));
- varname = &tmp;
- }
-
- if (IS_CONST != IS_UNUSED) {
- zend_class_entry *ce;
-
- if (IS_CONST == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ if (EXPECTED(Z_TYPE_P(array) == IS_ARRAY)) {
+ fe_ht = Z_ARRVAL_P(array);
+ ptr = (HashPointer*)EX_VAR((opline+1)->op1.var);
+ pos = ptr->pos;
+ if (UNEXPECTED(pos == INVALID_IDX)) {
+ /* reached end of iteration */
+ ZEND_VM_JMP(opline->op2.jmp_addr);
+ } else if (UNEXPECTED(ptr->ht != fe_ht)) {
+ ptr->ht = fe_ht;
+ pos = 0;
+ } else if (UNEXPECTED(fe_ht->nInternalPointer != ptr->pos)) {
+ if (fe_ht->u.flags & HASH_FLAG_PACKED) {
+ pos = ptr->h;
} else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(EG(exception) != NULL)) {
- if (IS_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
+ pos = fe_ht->arHash[ptr->h & fe_ht->nTableMask];
+ while (1) {
+ if (pos == INVALID_IDX) {
+ pos = fe_ht->nInternalPointer;
+ break;
+ } else if (fe_ht->arData[pos].h == ptr->h && fe_ht->arData[pos].key == ptr->key) {
+ break;
}
- zval_ptr_dtor_nogc(free_op1);
- HANDLE_EXCEPTION();
- }
- if (UNEXPECTED(ce == NULL)) {
- zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
+ pos = Z_NEXT(fe_ht->arData[pos].val);
}
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
}
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
}
- zend_std_unset_static_property(ce, Z_STR_P(varname), ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
- } else {
- target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
- }
-
- if (IS_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
- }
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_UNSET_DIM_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *container;
- zval *offset;
- zend_ulong hval;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
- }
- if (IS_VAR != IS_UNUSED) {
- ZVAL_DEREF(container);
- }
- SEPARATE_ZVAL_NOREF(container);
- offset = opline->op2.zv;
-
- if (IS_VAR != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
- HashTable *ht = Z_ARRVAL_P(container);
-offset_again:
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- zend_hash_index_del(ht, hval);
- break;
- case IS_LONG:
- hval = Z_LVAL_P(offset);
-num_index_dim:
- zend_hash_index_del(ht, hval);
- break;
- case IS_STRING:
- if (IS_CONST != IS_CONST) {
- if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
- goto num_index_dim;
- }
+ while (1) {
+ if (UNEXPECTED(pos >= fe_ht->nNumUsed)) {
+ /* reached end of iteration */
+ ZEND_VM_JMP(opline->op2.jmp_addr);
+ }
+ p = fe_ht->arData + pos;
+ value = &p->val;
+ if (UNEXPECTED(Z_TYPE_P(value) == IS_UNDEF)) {
+ pos++;
+ continue;
+ } else if (UNEXPECTED(Z_TYPE_P(value) == IS_INDIRECT)) {
+ value = Z_INDIRECT_P(value);
+ if (UNEXPECTED(Z_TYPE_P(value) == IS_UNDEF)) {
+ pos++;
+ continue;
}
- if (ht == &EG(symbol_table).ht) {
- zend_delete_global_variable(Z_STR_P(offset) TSRMLS_CC);
+ }
+ if (opline->extended_value & ZEND_FE_FETCH_BYREF) {
+ ZVAL_MAKE_REF(value);
+ Z_ADDREF_P(value);
+ ZVAL_REF(EX_VAR(opline->result.var), Z_REF_P(value));
+ } else {
+ ZVAL_COPY(EX_VAR(opline->result.var), value);
+ }
+ if (opline->extended_value & ZEND_FE_FETCH_WITH_KEY) {
+ if (!p->key) {
+ ZVAL_LONG(EX_VAR((opline+1)->result.var), p->h);
} else {
- zend_hash_del(ht, Z_STR_P(offset));
+ ZVAL_STR_COPY(EX_VAR((opline+1)->result.var), p->key);
}
- break;
- case IS_NULL:
- zend_hash_del(ht, STR_EMPTY_ALLOC());
- break;
- case IS_FALSE:
- hval = 0;
- goto num_index_dim;
- case IS_TRUE:
- hval = 1;
- goto num_index_dim;
- case IS_RESOURCE:
- hval = Z_RES_HANDLE_P(offset);
- goto num_index_dim;
- case IS_REFERENCE:
- offset = Z_REFVAL_P(offset);
- goto offset_again;
- break;
- default:
- zend_error(E_WARNING, "Illegal offset type in unset");
- break;
- }
-
- } else if (IS_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use object as array");
- }
-//??? if (IS_CONST == IS_CONST) {
-//??? zval_copy_ctor(offset);
-//??? }
- Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
-
- } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
- ZEND_VM_CONTINUE(); /* bailed out before */
- } else {
-
- }
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_UNSET_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *container;
- zval *offset;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
- }
- offset = opline->op2.zv;
-
- if (IS_VAR != IS_UNUSED) {
- ZVAL_DEREF(container);
- }
- if (IS_VAR == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
- if (Z_OBJ_HT_P(container)->unset_property) {
- Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to unset property of non-object");
- }
- }
-
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_VAR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *value;
-
- SAVE_OPLINE();
- if (IS_VAR == IS_CV &&
- IS_CONST == IS_UNUSED &&
- (opline->extended_value & ZEND_QUICK_SET)) {
- value = EX_VAR(opline->op1.var);
- if (opline->extended_value & ZEND_ISSET) {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- !i_zend_is_true(value TSRMLS_CC));
- CHECK_EXCEPTION();
+ }
+ break;
}
+ do {
+ pos++;
+ if (pos >= fe_ht->nNumUsed) {
+ fe_ht->nInternalPointer = ptr->pos = INVALID_IDX;
+ ZEND_VM_INC_OPCODE();
+ ZEND_VM_NEXT_OPCODE();
+ }
+ p = fe_ht->arData + pos;
+ } while (Z_TYPE(p->val) == IS_UNDEF ||
+ (Z_TYPE(p->val) == IS_INDIRECT &&
+ Z_TYPE_P(Z_INDIRECT(p->val)) == IS_UNDEF));
+ fe_ht->nInternalPointer = ptr->pos = pos;
+ ptr->h = fe_ht->arData[pos].h;
+ ptr->key = fe_ht->arData[pos].key;
+ ZEND_VM_INC_OPCODE();
ZEND_VM_NEXT_OPCODE();
- } else {
- zend_free_op free_op1;
- zval tmp, *varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- ZVAL_UNDEF(&tmp);
- if (IS_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
- ZVAL_STR(&tmp, zval_get_string(varname));
- varname = &tmp;
- }
+ } else if (EXPECTED(Z_TYPE_P(array) == IS_OBJECT)) {
+ zend_object_iterator *iter;
- if (IS_CONST != IS_UNUSED) {
- zend_class_entry *ce;
+ if ((iter = zend_iterator_unwrap(array TSRMLS_CC)) == NULL) {
+ /* plain object */
+ zend_object *zobj = Z_OBJ_P(array);
- if (IS_CONST == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ fe_ht = Z_OBJPROP_P(array);
+ ptr = (HashPointer*)EX_VAR((opline+1)->op1.var);
+ pos = ptr->pos;
+ if (pos == INVALID_IDX) {
+ /* reached end of iteration */
+ ZEND_VM_JMP(opline->op2.jmp_addr);
+ } else if (UNEXPECTED(ptr->ht != fe_ht)) {
+ ptr->ht = fe_ht;
+ pos = 0;
+ } else if (UNEXPECTED(fe_ht->nInternalPointer != ptr->pos)) {
+ if (fe_ht->u.flags & HASH_FLAG_PACKED) {
+ pos = ptr->h;
} else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ pos = fe_ht->arHash[ptr->h & fe_ht->nTableMask];
+ while (1) {
+ if (pos == INVALID_IDX) {
+ pos = fe_ht->nInternalPointer;
+ break;
+ } else if (fe_ht->arData[pos].h == ptr->h && fe_ht->arData[pos].key == ptr->key) {
+ break;
+ }
+ pos = Z_NEXT(fe_ht->arData[pos].val);
}
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
}
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
}
- value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
- } else {
- HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
- }
-
- if (IS_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
- }
- zval_ptr_dtor_nogc(free_op1);
-
- if (opline->extended_value & ZEND_ISSET) {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- value && Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- !value || !i_zend_is_true(value TSRMLS_CC));
- }
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-}
-
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *container;
- int result;
- zend_ulong hval;
- zval *offset;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
- offset = opline->op2.zv;
+ while (1) {
+ if (UNEXPECTED(pos >= fe_ht->nNumUsed)) {
+ /* reached end of iteration */
+ ZEND_VM_JMP(opline->op2.jmp_addr);
+ }
- if (IS_VAR != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
- HashTable *ht = Z_ARRVAL_P(container);
- zval *value;
- zend_string *str;
+ p = fe_ht->arData + pos;
+ value = &p->val;
+ if (UNEXPECTED(Z_TYPE_P(value) == IS_UNDEF)) {
+ pos++;
+ continue;
+ } else if (UNEXPECTED(Z_TYPE_P(value) == IS_INDIRECT)) {
+ value = Z_INDIRECT_P(value);
+ if (UNEXPECTED(Z_TYPE_P(value) == IS_UNDEF)) {
+ pos++;
+ continue;
+ }
+ }
-isset_again:
- if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
- str = Z_STR_P(offset);
- if (IS_CONST != IS_CONST) {
- if (ZEND_HANDLE_NUMERIC(str, hval)) {
- goto num_index_prop;
+ if (UNEXPECTED(!p->key)) {
+ if (opline->extended_value & ZEND_FE_FETCH_WITH_KEY) {
+ ZVAL_LONG(EX_VAR((opline+1)->result.var), p->h);
+ }
+ break;
+ } else if (zend_check_property_access(zobj, p->key TSRMLS_CC) == SUCCESS) {
+ if (opline->extended_value & ZEND_FE_FETCH_WITH_KEY) {
+ if (p->key->val[0]) {
+ ZVAL_STR_COPY(EX_VAR((opline+1)->result.var), p->key);
+ } else {
+ const char *class_name, *prop_name;
+ size_t prop_name_len;
+ zend_unmangle_property_name_ex(
+ p->key, &class_name, &prop_name, &prop_name_len);
+ ZVAL_STRINGL(EX_VAR((opline+1)->result.var), prop_name, prop_name_len);
+ }
+ }
+ break;
}
+ pos++;
}
-str_index_prop:
- value = zend_hash_find_ind(ht, str);
- } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
- hval = Z_LVAL_P(offset);
-num_index_prop:
- value = zend_hash_index_find(ht, hval);
- } else {
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- goto num_index_prop;
- case IS_NULL:
- str = STR_EMPTY_ALLOC();
- goto str_index_prop;
- case IS_FALSE:
- hval = 0;
- goto num_index_prop;
- case IS_TRUE:
- hval = 1;
- goto num_index_prop;
- case IS_RESOURCE:
- hval = Z_RES_HANDLE_P(offset);
- goto num_index_prop;
- case IS_REFERENCE:
- offset = Z_REFVAL_P(offset);
- goto isset_again;
- default:
- zend_error(E_WARNING, "Illegal offset type in isset or empty");
- value = NULL;
- break;
+ if (opline->extended_value & ZEND_FE_FETCH_BYREF) {
+ ZVAL_MAKE_REF(value);
+ Z_ADDREF_P(value);
+ ZVAL_REF(EX_VAR(opline->result.var), Z_REF_P(value));
+ } else {
+ ZVAL_COPY(EX_VAR(opline->result.var), value);
}
- }
-
- if (opline->extended_value & ZEND_ISSET) {
- /* > IS_NULL means not IS_UNDEF and not IS_NULL */
- result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
- }
- } else if (IS_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
- result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
+ do {
+ pos++;
+ if (pos >= fe_ht->nNumUsed) {
+ fe_ht->nInternalPointer = ptr->pos = INVALID_IDX;
+ ZEND_VM_INC_OPCODE();
+ ZEND_VM_NEXT_OPCODE();
+ }
+ p = fe_ht->arData + pos;
+ } while (Z_TYPE(p->val) == IS_UNDEF ||
+ (Z_TYPE(p->val) == IS_INDIRECT &&
+ Z_TYPE_P(Z_INDIRECT(p->val)) == IS_UNDEF) ||
+ (EXPECTED(p->key != NULL) &&
+ zend_check_property_access(zobj, p->key TSRMLS_CC) == FAILURE));
+ fe_ht->nInternalPointer = ptr->pos = pos;
+ ptr->h = fe_ht->arData[pos].h;
+ ptr->key = fe_ht->arData[pos].key;
+ ZEND_VM_INC_OPCODE();
+ ZEND_VM_NEXT_OPCODE();
} else {
- zend_error(E_NOTICE, "Trying to check element of non-array");
- result = 0;
- }
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
- }
- } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
- zval tmp;
-
- result = 0;
- if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
- if (IS_CONST == IS_CV || IS_CONST == IS_VAR) {
- ZVAL_DEREF(offset);
+ /* !iter happens from exception */
+ if (iter && ++iter->index > 0) {
+ /* This could cause an endless loop if index becomes zero again.
+ * In case that ever happens we need an additional flag. */
+ iter->funcs->move_forward(iter TSRMLS_CC);
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ zval_ptr_dtor(array_ref);
+ HANDLE_EXCEPTION();
+ }
}
- if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
- || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
- && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
- ZVAL_DUP(&tmp, offset);
- convert_to_long(&tmp);
- offset = &tmp;
+ /* If index is zero we come from FE_RESET and checked valid() already. */
+ if (!iter || (iter->index > 0 && iter->funcs->valid(iter TSRMLS_CC) == FAILURE)) {
+ /* reached end of iteration */
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ zval_ptr_dtor(array_ref);
+ HANDLE_EXCEPTION();
+ }
+ ZEND_VM_JMP(opline->op2.jmp_addr);
}
- }
- if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
- if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
- if ((opline->extended_value & ZEND_ISSET) ||
- Z_STRVAL_P(container)[offset->value.lval] != '0') {
- result = 1;
+ value = iter->funcs->get_current_data(iter TSRMLS_CC);
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ zval_ptr_dtor(array_ref);
+ HANDLE_EXCEPTION();
+ }
+ if (!value) {
+ /* failure in get_current_data */
+ ZEND_VM_JMP(opline->op2.jmp_addr);
+ }
+ if (opline->extended_value & ZEND_FE_FETCH_BYREF) {
+ ZVAL_MAKE_REF(value);
+ Z_ADDREF_P(value);
+ ZVAL_REF(EX_VAR(opline->result.var), Z_REF_P(value));
+ } else {
+ ZVAL_COPY(EX_VAR(opline->result.var), value);
+ }
+ if (opline->extended_value & ZEND_FE_FETCH_WITH_KEY) {
+ if (iter->funcs->get_current_key) {
+ iter->funcs->get_current_key(iter, EX_VAR((opline+1)->result.var) TSRMLS_CC);
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ zval_ptr_dtor(array_ref);
+ HANDLE_EXCEPTION();
+ }
+ } else {
+ ZVAL_LONG(EX_VAR((opline+1)->result.var), iter->index);
}
}
- }
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
+ ZEND_VM_INC_OPCODE();
+ ZEND_VM_NEXT_OPCODE();
}
} else {
- result = ((opline->extended_value & ZEND_ISSET) == 0);
+ zend_error(E_WARNING, "Invalid argument supplied for foreach()");
+ ZEND_VM_JMP(opline->op2.jmp_addr);
}
-
- ZVAL_BOOL(EX_VAR(opline->result.var), result);
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_EXIT_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || (IS_VAR != IS_UNUSED)
USE_OPLINE
- zend_free_op free_op1;
- zval *container;
- int result;
- zval *offset;
SAVE_OPLINE();
- container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
- offset = opline->op2.zv;
+ if (IS_VAR != IS_UNUSED) {
+ zend_free_op free_op1;
+ zval *ptr = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
- if (IS_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
- result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+ if (Z_TYPE_P(ptr) == IS_LONG) {
+ EG(exit_status) = Z_LVAL_P(ptr);
} else {
- zend_error(E_NOTICE, "Trying to check property of non-object");
- result = 0;
- }
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
+ zend_print_variable(ptr TSRMLS_CC);
}
- } else {
- result = ((opline->extended_value & ZEND_ISSET) == 0);
+ zval_ptr_dtor_nogc(free_op1);
}
-
- ZVAL_BOOL(EX_VAR(opline->result.var), result);
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+#endif
+ zend_bailout();
+ ZEND_VM_NEXT_OPCODE(); /* Never reached */
}
-static int ZEND_FASTCALL ZEND_INSTANCEOF_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_JMP_SET_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
- zval *expr;
- zend_bool result;
+ zval *value;
+ int is_ref = 0;
SAVE_OPLINE();
- expr = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
- if (Z_TYPE_P(expr) == IS_OBJECT) {
- zend_class_entry *ce;
+ value = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (IS_CONST == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, ZEND_FETCH_CLASS_NO_AUTOLOAD TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- ZVAL_FALSE(EX_VAR(opline->result.var));
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+ if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && Z_ISREF_P(value)) {
+ is_ref = 1;
+ value = Z_REFVAL_P(value);
+ }
+ if (i_zend_is_true(value TSRMLS_CC)) {
+ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), value);
+ if (IS_VAR == IS_CONST) {
+ if (UNEXPECTED(Z_OPT_COPYABLE_P(value))) {
+ zval_copy_ctor_func(EX_VAR(opline->result.var));
}
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
+ } else if (IS_VAR == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+ } else if (IS_VAR == IS_VAR && is_ref) {
+ if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+ zval_ptr_dtor_nogc(free_op1);
}
- result = instanceof_function(Z_OBJCE_P(expr), ce TSRMLS_CC);
- } else {
- result = 0;
+ ZEND_VM_JMP(opline->op2.jmp_addr);
}
- ZVAL_BOOL(EX_VAR(opline->result.var), result);
+
zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_YIELD_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_COALESCE_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zend_free_op free_op1;
+ zval *value;
+ int is_ref = 0;
- /* The generator object is stored in EX(return_value) */
- zend_generator *generator = (zend_generator *) EX(return_value);
+ SAVE_OPLINE();
+ value = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
- zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
+ if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && Z_ISREF_P(value)) {
+ is_ref = 1;
+ value = Z_REFVAL_P(value);
}
- /* Destroy the previously yielded value */
- zval_ptr_dtor(&generator->value);
-
- /* Destroy the previously yielded key */
- zval_ptr_dtor(&generator->key);
-
- /* Set the new yielded value */
- if (IS_VAR != IS_UNUSED) {
- zend_free_op free_op1;
-
- if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
- /* Constants and temporary variables aren't yieldable by reference,
- * but we still allow them with a notice. */
- if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
- zval *value;
-
- zend_error(E_NOTICE, "Only variable references should be yielded by reference");
-
- value = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- ZVAL_COPY_VALUE(&generator->value, value);
- if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
-
- /* Temporary variables don't need ctor copying */
- if (IS_VAR != IS_TMP_VAR) {
- zval_opt_copy_ctor(&generator->value);
- }
- } else {
- zval *value_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
- }
-
- /* If a function call result is yielded and the function did
- * not return by reference we throw a notice. */
- if (IS_VAR == IS_VAR &&
- (value_ptr == &EG(uninitialized_zval) ||
- (opline->extended_value == ZEND_RETURNS_FUNCTION &&
- !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
- zend_error(E_NOTICE, "Only variable references should be yielded by reference");
- } else {
- ZVAL_MAKE_REF(value_ptr);
- }
- ZVAL_COPY(&generator->value, value_ptr);
-
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- }
- } else {
- zval *value = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- /* Consts, temporary variables and references need copying */
- if (IS_VAR == IS_CONST) {
- ZVAL_DUP(&generator->value, value);
- } else if (IS_VAR == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&generator->value, value);
- } else if ((IS_VAR == IS_CV || IS_VAR == IS_VAR) && Z_ISREF_P(value)) {
- ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
- zval_ptr_dtor_nogc(free_op1);
- } else {
- ZVAL_COPY_VALUE(&generator->value, value);
- if (IS_VAR == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
- }
+ if (Z_TYPE_P(value) > IS_NULL) {
+ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), value);
+ if (IS_VAR == IS_CONST) {
+ if (UNEXPECTED(Z_OPT_COPYABLE_P(value))) {
+ zval_copy_ctor_func(EX_VAR(opline->result.var));
}
+ } else if (IS_VAR == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+ } else if (IS_VAR == IS_VAR && is_ref) {
+ if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+ zval_ptr_dtor_nogc(free_op1);
}
- } else {
- /* If no value was specified yield null */
- ZVAL_NULL(&generator->value);
+ ZEND_VM_JMP(opline->op2.jmp_addr);
}
- /* Set the new yielded key */
- if (IS_CONST != IS_UNUSED) {
+ zval_ptr_dtor_nogc(free_op1);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- zval *key = opline->op2.zv;
+static int ZEND_FASTCALL ZEND_QM_ASSIGN_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+ zval *value;
- /* Consts, temporary variables and references need copying */
- if (IS_CONST == IS_CONST) {
- ZVAL_DUP(&generator->key, key);
- } else if (IS_CONST == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&generator->key, key);
- } else if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) && Z_ISREF_P(key)) {
- ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
+ SAVE_OPLINE();
+ value = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- } else {
- ZVAL_COPY_VALUE(&generator->key, key);
- if (IS_CONST == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
+ if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && Z_ISREF_P(value)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), Z_REFVAL_P(value));
+ zval_ptr_dtor_nogc(free_op1);
+ } else {
+ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), value);
+ if (IS_VAR == IS_CONST) {
+ if (UNEXPECTED(Z_OPT_COPYABLE_P(value))) {
+ zval_copy_ctor_func(EX_VAR(opline->result.var));
}
+ } else if (IS_VAR == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
}
-
- if (Z_TYPE(generator->key) == IS_LONG
- && Z_LVAL(generator->key) > generator->largest_used_integer_key
- ) {
- generator->largest_used_integer_key = Z_LVAL(generator->key);
- }
- } else {
- /* If no key was specified we use auto-increment keys */
- generator->largest_used_integer_key++;
- ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
- }
-
- if (RETURN_VALUE_USED(opline)) {
- /* If the return value of yield is used set the send
- * target and initialize it to NULL */
- generator->send_target = EX_VAR(opline->result.var);
- ZVAL_NULL(generator->send_target);
- } else {
- generator->send_target = NULL;
}
+ ZEND_VM_NEXT_OPCODE();
+}
- /* We increment to the next op, so we are at the correct position when the
- * generator is resumed. */
- ZEND_VM_INC_OPCODE();
+static int ZEND_FASTCALL ZEND_STRLEN_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zval *value;
+ zend_free_op free_op1;
- /* The GOTO VM uses a local opline variable. We need to set the opline
- * variable in execute_data so we don't resume at an old position. */
SAVE_OPLINE();
+ value = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
+ if (EXPECTED(Z_TYPE_P(value) == IS_STRING)) {
+ ZVAL_LONG(EX_VAR(opline->result.var), Z_STRLEN_P(value));
+ } else {
+ if (Z_TYPE_P(value) < IS_TRUE) {
+ ZVAL_LONG(EX_VAR(opline->result.var), 0);
+ } else if (Z_TYPE_P(value) == IS_TRUE) {
+ ZVAL_LONG(EX_VAR(opline->result.var), 1);
+ } else if (Z_TYPE_P(value) <= IS_DOUBLE) {
+ zend_string *str = zval_get_string(value);
+ ZVAL_LONG(EX_VAR(opline->result.var), str->len);
+ zend_string_release(str);
+ } else if (Z_TYPE_P(value) == IS_OBJECT) {
+ zend_string *str;
+ zval tmp;
- ZEND_VM_RETURN();
+ ZVAL_COPY(&tmp, value);
+ if (parse_arg_object_to_str(&tmp, &str, IS_STRING TSRMLS_CC) == FAILURE) {
+ goto strlen_error;
+ }
+ ZVAL_LONG(EX_VAR(opline->result.var), str->len);
+ zval_dtor(&tmp);
+ } else {
+strlen_error:
+ zend_error(E_WARNING, "strlen() expects parameter 1 to be string, %s given", zend_get_type_by_const(Z_TYPE_P(value)));
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ }
+ zval_ptr_dtor_nogc(free_op1);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_POW_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_TYPE_CHECK_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *value;
zend_free_op free_op1;
SAVE_OPLINE();
- pow_function(EX_VAR(opline->result.var),
- _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- opline->op2.zv TSRMLS_CC);
+ value = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
+ switch (opline->extended_value) {
+ case IS_NULL:
+ case IS_LONG:
+ case IS_DOUBLE:
+ case IS_STRING:
+ case IS_ARRAY:
+ ZVAL_BOOL(EX_VAR(opline->result.var), Z_TYPE_P(value) == opline->extended_value);
+ break;
+ case _IS_BOOL:
+ ZVAL_BOOL(EX_VAR(opline->result.var), Z_TYPE_P(value) == IS_TRUE || Z_TYPE_P(value) == IS_FALSE);
+ break;
+ case IS_OBJECT:
+ if (Z_TYPE_P(value) == opline->extended_value) {
+ zend_class_entry *ce = Z_OBJCE_P(value);
+ if (ce->name->len == sizeof("__PHP_Incomplete_Class") - 1
+ && !strncmp(ce->name->val, "__PHP_Incomplete_Class", ce->name->len)) {
+ ZVAL_FALSE(EX_VAR(opline->result.var));
+ } else {
+ ZVAL_TRUE(EX_VAR(opline->result.var));
+ }
+ } else {
+ ZVAL_FALSE(EX_VAR(opline->result.var));
+ }
+ break;
+ case IS_RESOURCE:
+ if (Z_TYPE_P(value) == opline->extended_value) {
+ const char *type_name = zend_rsrc_list_get_rsrc_type(Z_RES_P(value) TSRMLS_CC);
+ ZVAL_BOOL(EX_VAR(opline->result.var), type_name != NULL);
+ } else {
+ ZVAL_FALSE(EX_VAR(opline->result.var));
+ }
+ break;
+ EMPTY_SWITCH_DEFAULT_CASE()
+ }
zval_ptr_dtor_nogc(free_op1);
-
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_binary_assign_op_helper_SPEC_VAR_CONST(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_MOD_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_MOD_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
SAVE_OPLINE();
fast_mod_function(EX_VAR(opline->result.var),
_get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ opline->op2.zv TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
- zval_ptr_dtor_nogc(free_op2);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_SL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
SAVE_OPLINE();
shift_left_function(EX_VAR(opline->result.var),
_get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ opline->op2.zv TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
- zval_ptr_dtor_nogc(free_op2);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_SR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
SAVE_OPLINE();
shift_right_function(EX_VAR(opline->result.var),
_get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ opline->op2.zv TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
- zval_ptr_dtor_nogc(free_op2);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_CONCAT_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_CONCAT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
SAVE_OPLINE();
concat_function(EX_VAR(opline->result.var),
_get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ opline->op2.zv TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
- zval_ptr_dtor_nogc(free_op2);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_IS_IDENTICAL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_IS_IDENTICAL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
SAVE_OPLINE();
fast_is_identical_function(EX_VAR(opline->result.var),
_get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ opline->op2.zv TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
- zval_ptr_dtor_nogc(free_op2);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_IS_NOT_IDENTICAL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_IS_NOT_IDENTICAL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *result = EX_VAR(opline->result.var);
SAVE_OPLINE();
fast_is_not_identical_function(result,
_get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ opline->op2.zv TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
- zval_ptr_dtor_nogc(free_op2);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_BW_OR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BW_OR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
SAVE_OPLINE();
bitwise_or_function(EX_VAR(opline->result.var),
_get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ opline->op2.zv TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
- zval_ptr_dtor_nogc(free_op2);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_BW_AND_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BW_AND_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
SAVE_OPLINE();
bitwise_and_function(EX_VAR(opline->result.var),
_get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ opline->op2.zv TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
- zval_ptr_dtor_nogc(free_op2);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_BW_XOR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BW_XOR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
SAVE_OPLINE();
bitwise_xor_function(EX_VAR(opline->result.var),
_get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ opline->op2.zv TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
- zval_ptr_dtor_nogc(free_op2);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_BOOL_XOR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BOOL_XOR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
SAVE_OPLINE();
boolean_xor_function(EX_VAR(opline->result.var),
_get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ opline->op2.zv TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
- zval_ptr_dtor_nogc(free_op2);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2, free_op_data1;
+ zend_free_op free_op1, free_op_data1;
zval *object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- zval *property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ zval *property = opline->op2.zv;
zval *value;
zval *zptr;
if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
zend_error(E_WARNING, "Attempt to assign property of non-object");
- zval_ptr_dtor_nogc(free_op2);
+
FREE_OP(free_op_data1);
if (RETURN_VALUE_USED(opline)) {
/* here we are sure we are dealing with an object */
if (opline->extended_value == ZEND_ASSIGN_OBJ
&& EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
ZVAL_DEREF(zptr);
SEPARATE_ZVAL_NOREF(zptr);
if (opline->extended_value == ZEND_ASSIGN_OBJ) {
if (Z_OBJ_HT_P(object)->read_property) {
- z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+ z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
}
} else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
if (Z_OBJ_HT_P(object)->read_dimension) {
SEPARATE_ZVAL_IF_NOT_REF(z);
binary_op(z, z, value TSRMLS_CC);
if (opline->extended_value == ZEND_ASSIGN_OBJ) {
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+ Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
} else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
}
}
}
- zval_ptr_dtor_nogc(free_op2);
FREE_OP(free_op_data1);
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2, free_op_data1;
+ zend_free_op free_op1, free_op_data1;
zval *var_ptr, rv;
zval *value, *container;
if (IS_VAR == IS_VAR && !(free_op1 != NULL)) {
Z_ADDREF_P(container); /* undo the effect of get_obj_zval_ptr_ptr() */
}
- return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else {
- zval *dim = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ zval *dim = opline->op2.zv;
- zend_fetch_dimension_address_RW(&rv, container, dim, IS_TMP_VAR TSRMLS_CC);
+ zend_fetch_dimension_address_RW(&rv, container, dim, IS_CONST TSRMLS_CC);
value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
var_ptr = Z_INDIRECT(rv);
}
}
- zval_ptr_dtor_nogc(free_op2);
FREE_OP(free_op_data1);
if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *var_ptr;
zval *value;
SAVE_OPLINE();
- value = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ value = opline->op2.zv;
var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
}
}
- zval_ptr_dtor_nogc(free_op2);
if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_VAR_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_VAR_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_VAR_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_VAR_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_VAR_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_VAR_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_VAR_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_VAR_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_VAR_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_VAR_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_VAR_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_TMP(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *object;
zval *property;
zval *retval;
SAVE_OPLINE();
object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ property = opline->op2.zv;
retval = EX_VAR(opline->result.var);
if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- zval_ptr_dtor_nogc(free_op2);
+
if (RETURN_VALUE_USED(opline)) {
ZVAL_NULL(retval);
}
/* here we are sure we are dealing with an object */
if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
ZVAL_DEREF(zptr);
SEPARATE_ZVAL_NOREF(zptr);
zval rv;
if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+ zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
zval rv;
SEPARATE_ZVAL_IF_NOT_REF(z);
incdec_op(z);
ZVAL_COPY_VALUE(retval, z);
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+ Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
SELECTIVE_PZVAL_LOCK(retval, opline);
zval_ptr_dtor(z);
} else {
}
}
- zval_ptr_dtor_nogc(free_op2);
if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_pre_incdec_property_helper_SPEC_VAR_TMP(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_pre_incdec_property_helper_SPEC_VAR_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_pre_incdec_property_helper_SPEC_VAR_TMP(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_pre_incdec_property_helper_SPEC_VAR_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_TMP(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *object;
zval *property;
zval *retval;
SAVE_OPLINE();
object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ property = opline->op2.zv;
retval = EX_VAR(opline->result.var);
if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- zval_ptr_dtor_nogc(free_op2);
+
ZVAL_NULL(retval);
if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
/* here we are sure we are dealing with an object */
if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
ZVAL_DEREF(zptr);
ZVAL_COPY_VALUE(retval, zptr);
} else {
if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
zval rv;
- zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+ zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
zval z_copy;
if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
ZVAL_DUP(&z_copy, z);
incdec_op(&z_copy);
if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
- Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+ Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
zval_ptr_dtor(&z_copy);
zval_ptr_dtor(z);
} else {
}
}
- zval_ptr_dtor_nogc(free_op2);
if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_post_incdec_property_helper_SPEC_VAR_TMP(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_post_incdec_property_helper_SPEC_VAR_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_post_incdec_property_helper_SPEC_VAR_TMP(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_post_incdec_property_helper_SPEC_VAR_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *container;
SAVE_OPLINE();
container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+
zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_W_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_W_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *container;
SAVE_OPLINE();
zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
ZVAL_DEREF(container);
- zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+
if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_RW_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_RW_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *container;
SAVE_OPLINE();
zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
ZVAL_DEREF(container);
- zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+
if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_IS_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_IS_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *container;
SAVE_OPLINE();
container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+
zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *container;
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
SAVE_OPLINE();
zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
ZVAL_DEREF(container);
- zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
+ zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
- zval_ptr_dtor_nogc(free_op2);
+
if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
} else {
- if (IS_TMP_VAR == IS_UNUSED) {
+ if (IS_CONST == IS_UNUSED) {
zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
}
container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+
zval_ptr_dtor_nogc(free_op1);
}
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_UNSET_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_UNSET_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *container;
SAVE_OPLINE();
zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
ZVAL_DEREF(container);
- zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+
if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
zval *container;
- zend_free_op free_op2;
+
zval *offset;
SAVE_OPLINE();
container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ offset = opline->op2.zv;
if ((IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
/* here we are sure we are dealing with an object */
do {
- if (IS_TMP_VAR == IS_CONST &&
+ if (IS_CONST == IS_CONST &&
EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
zend_object *zobj = Z_OBJ_P(container);
}
}
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+ retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
if (retval != EX_VAR(opline->result.var)) {
ZVAL_COPY(EX_VAR(opline->result.var), retval);
} while (0);
}
- zval_ptr_dtor_nogc(free_op2);
zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_W_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_W_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *property;
zval *container;
SAVE_OPLINE();
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ property = opline->op2.zv;
container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
}
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+
if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_RW_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_RW_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *property;
zval *container;
SAVE_OPLINE();
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ property = opline->op2.zv;
container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
}
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
+
if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
zval *container;
- zend_free_op free_op2;
+
zval *offset;
SAVE_OPLINE();
container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ offset = opline->op2.zv;
if ((IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
/* here we are sure we are dealing with an object */
do {
- if (IS_TMP_VAR == IS_CONST &&
+ if (IS_CONST == IS_CONST &&
EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
zend_object *zobj = Z_OBJ_P(container);
}
}
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+ retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
if (retval != EX_VAR(opline->result.var)) {
ZVAL_COPY(EX_VAR(opline->result.var), retval);
} while (0);
}
- zval_ptr_dtor_nogc(free_op2);
zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *container;
if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
/* Behave like FETCH_OBJ_W */
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *property;
SAVE_OPLINE();
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ property = opline->op2.zv;
container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
}
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+
if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
} else {
- return ZEND_FETCH_OBJ_R_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return ZEND_FETCH_OBJ_R_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_UNSET_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_UNSET_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *container, *property;
SAVE_OPLINE();
container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ property = opline->op2.zv;
if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
}
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
+
if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_LIST_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
+ zval *container;
+
+ SAVE_OPLINE();
+ container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
+
+ if (EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
+
+ zval *value = zend_fetch_dimension_address_inner(Z_ARRVAL_P(container), opline->op2.zv, IS_CONST, BP_VAR_R TSRMLS_CC);
+
+ ZVAL_COPY(EX_VAR(opline->result.var), value);
+ } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT) &&
+ EXPECTED(Z_OBJ_HT_P(container)->read_dimension)) {
+ zval *result = EX_VAR(opline->result.var);
+ zval *retval = Z_OBJ_HT_P(container)->read_dimension(container, opline->op2.zv, BP_VAR_R, result TSRMLS_CC);
+
+ if (retval) {
+ if (result != retval) {
+ ZVAL_COPY(result, retval);
+ }
+ } else {
+ ZVAL_NULL(result);
+ }
+ } else {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_ASSIGN_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
zval *object;
zval *property_name;
SAVE_OPLINE();
object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- property_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ property_name = opline->op2.zv;
if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
- zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_VAR, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_VAR, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+
if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
/* assign_obj has two opcodes! */
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_DIM_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_DIM_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
}
ZVAL_DEREF(object_ptr);
if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
- zend_free_op free_op2;
- zval *property_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_VAR, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ zval *property_name = opline->op2.zv;
+
+ zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_VAR, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+
} else {
- zend_free_op free_op2, free_op_data1;
+ zend_free_op free_op_data1;
zval rv;
zval *value;
- zval *dim = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ zval *dim = opline->op2.zv;
zval *variable_ptr;
if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+
value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
FREE_OP(free_op_data1);
} else {
- zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_TMP_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_CONST TSRMLS_CC);
+
value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
variable_ptr = Z_INDIRECT(rv);
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *value;
zval *variable_ptr;
SAVE_OPLINE();
- value = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ value = opline->op2.zv;
variable_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
if (IS_VAR == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
- if (IS_TMP_VAR == IS_TMP_VAR) {
- zval_ptr_dtor_nogc(free_op2);
+ if (IS_CONST == IS_TMP_VAR) {
+
}
if (RETURN_VALUE_USED(opline)) {
ZVAL_NULL(EX_VAR(opline->result.var));
}
} else {
- value = zend_assign_to_variable(variable_ptr, value, IS_TMP_VAR TSRMLS_CC);
+ value = zend_assign_to_variable(variable_ptr, value, IS_CONST TSRMLS_CC);
if (RETURN_VALUE_USED(opline)) {
ZVAL_COPY(EX_VAR(opline->result.var), value);
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *function_name;
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *object;
zend_function *fbc;
zend_class_entry *called_scope;
SAVE_OPLINE();
- function_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ function_name = opline->op2.zv;
- if (IS_TMP_VAR != IS_CONST &&
+ if (IS_CONST != IS_CONST &&
UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
if (UNEXPECTED(EG(exception) != NULL)) {
HANDLE_EXCEPTION();
uint32_t nesting = 1;
if (UNEXPECTED(EG(exception) != NULL)) {
- zval_ptr_dtor_nogc(free_op2);
+
HANDLE_EXCEPTION();
}
zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s", Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
- zval_ptr_dtor_nogc(free_op2);
+
zval_ptr_dtor_nogc(free_op1);
if (EG(exception) != NULL) {
obj = Z_OBJ_P(object);
called_scope = obj->ce;
- if (IS_TMP_VAR != IS_CONST ||
+ if (IS_CONST != IS_CONST ||
EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
zend_object *orig_obj = obj;
}
/* First, locate the function. */
- fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_TMP_VAR == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
+ fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_CONST == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
if (UNEXPECTED(fbc == NULL)) {
zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
}
- if (IS_TMP_VAR == IS_CONST &&
+ if (IS_CONST == IS_CONST &&
EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
EXPECTED(obj == orig_obj)) {
EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *function_name;
}
if (IS_VAR == IS_CONST &&
- IS_TMP_VAR == IS_CONST &&
+ IS_CONST == IS_CONST &&
CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
fbc = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
} else if (IS_VAR != IS_CONST &&
- IS_TMP_VAR == IS_CONST &&
+ IS_CONST == IS_CONST &&
(fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce))) {
/* do nothing */
- } else if (IS_TMP_VAR != IS_UNUSED) {
- zend_free_op free_op2;
+ } else if (IS_CONST != IS_UNUSED) {
- function_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- if (IS_TMP_VAR != IS_CONST) {
+
+ function_name = opline->op2.zv;
+ if (IS_CONST != IS_CONST) {
if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
if (UNEXPECTED(EG(exception) != NULL)) {
HANDLE_EXCEPTION();
if (ce->get_static_method) {
fbc = ce->get_static_method(ce, Z_STR_P(function_name) TSRMLS_CC);
} else {
- fbc = zend_std_get_static_method(ce, Z_STR_P(function_name), ((IS_TMP_VAR == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
+ fbc = zend_std_get_static_method(ce, Z_STR_P(function_name), ((IS_CONST == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
}
if (UNEXPECTED(fbc == NULL)) {
zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name->val, Z_STRVAL_P(function_name));
}
- if (IS_TMP_VAR == IS_CONST &&
+ if (IS_CONST == IS_CONST &&
EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0)) {
if (IS_VAR == IS_CONST) {
CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), ce, fbc);
}
}
- if (IS_TMP_VAR != IS_CONST) {
- zval_ptr_dtor_nogc(free_op2);
+ if (IS_CONST != IS_CONST) {
+
}
} else {
if (UNEXPECTED(ce->constructor == NULL)) {
EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
fbc, opline->extended_value, ce, object, EX(call) TSRMLS_CC);
- if (IS_TMP_VAR == IS_UNUSED) {
+ if (IS_CONST == IS_UNUSED) {
EX(call)->return_value = NULL;
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_CASE_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_CONSTANT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *result = EX_VAR(opline->result.var);
SAVE_OPLINE();
- fast_equal_function(result,
- _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ if (IS_VAR == IS_UNUSED) {
+ zend_constant *c;
+ zval *retval;
- zval_ptr_dtor_nogc(free_op2);
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ c = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ } else if ((c = zend_quick_get_constant(opline->op2.zv + 1, opline->extended_value TSRMLS_CC)) == NULL) {
+ if ((opline->extended_value & IS_CONSTANT_UNQUALIFIED) != 0) {
+ char *actual = (char *)zend_memrchr(Z_STRVAL_P(opline->op2.zv), '\\', Z_STRLEN_P(opline->op2.zv));
+ if (!actual) {
+ ZVAL_STR(EX_VAR(opline->result.var), zend_string_copy(Z_STR_P(opline->op2.zv)));
+ } else {
+ actual++;
+ ZVAL_STRINGL(EX_VAR(opline->result.var),
+ actual, Z_STRLEN_P(opline->op2.zv) - (actual - Z_STRVAL_P(opline->op2.zv)));
+ }
+ /* non-qualified constant - allow text substitution */
+ zend_error(E_NOTICE, "Use of undefined constant %s - assumed '%s'",
+ Z_STRVAL_P(EX_VAR(opline->result.var)), Z_STRVAL_P(EX_VAR(opline->result.var)));
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ } else {
+ zend_error_noreturn(E_ERROR, "Undefined constant '%s'", Z_STRVAL_P(opline->op2.zv));
+ }
+ } else {
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), c);
+ }
+ retval = EX_VAR(opline->result.var);
+ ZVAL_COPY_VALUE(retval, &c->value);
+ if (Z_OPT_COPYABLE_P(retval) || Z_OPT_REFCOUNTED_P(retval)) {
+ if (Z_OPT_COPYABLE_P(retval)) {
+ zval_copy_ctor_func(retval);
+ } else {
+ Z_ADDREF_P(retval);
+ }
+ }
+ } else {
+ /* class constant */
+ zend_class_entry *ce;
+ zval *value;
+
+ if (IS_VAR == IS_CONST) {
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ value = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ ZVAL_DEREF(value);
+ ZVAL_DUP(EX_VAR(opline->result.var), value);
+ goto constant_fetch_end;
+ } else if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv));
+ } else {
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op1.zv), opline->op1.zv + 1, 0 TSRMLS_CC);
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ if (UNEXPECTED(ce == NULL)) {
+ zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
+ }
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op1.zv), ce);
+ }
+ } else {
+ ce = Z_CE_P(EX_VAR(opline->op1.var));
+ if ((value = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce)) != NULL) {
+ ZVAL_DEREF(value);
+ ZVAL_DUP(EX_VAR(opline->result.var), value);
+ goto constant_fetch_end;
+ }
+ }
+
+ if (EXPECTED((value = zend_hash_find(&ce->constants_table, Z_STR_P(opline->op2.zv))) != NULL)) {
+ ZVAL_DEREF(value);
+ if (Z_CONSTANT_P(value)) {
+ EG(scope) = ce;
+ zval_update_constant(value, 1 TSRMLS_CC);
+ EG(scope) = EX(func)->op_array.scope;
+ }
+ if (IS_VAR == IS_CONST) {
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), value);
+ } else {
+ CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce, value);
+ }
+ ZVAL_DUP(EX_VAR(opline->result.var), value);
+ } else if (Z_STRLEN_P(opline->op2.zv) == sizeof("class")-1 && memcmp(Z_STRVAL_P(opline->op2.zv), "class", sizeof("class") - 1) == 0) {
+ /* "class" is assigned as a case-sensitive keyword from zend_do_resolve_class_name */
+ ZVAL_STR_COPY(EX_VAR(opline->result.var), ce->name);
+ } else {
+ zend_error_noreturn(E_ERROR, "Undefined class constant '%s'", Z_STRVAL_P(opline->op2.zv));
+ }
+ }
+constant_fetch_end:
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
}
}
- if (IS_TMP_VAR != IS_UNUSED) {
- zend_free_op free_op2;
- zval *offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ if (IS_CONST != IS_UNUSED) {
+
+ zval *offset = opline->op2.zv;
zend_string *str;
zend_ulong hval;
break;
case IS_STRING:
str = Z_STR_P(offset);
- if (IS_TMP_VAR != IS_CONST) {
+ if (IS_CONST != IS_CONST) {
if (ZEND_HANDLE_NUMERIC(str, hval)) {
goto num_index;
}
/* do nothing */
break;
}
- zval_ptr_dtor_nogc(free_op2);
+
} else {
zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
zval *array;
uint32_t size;
ZEND_VM_NEXT_OPCODE();
#if 0 || IS_VAR != IS_UNUSED
} else {
- return ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
#endif
}
}
-static int ZEND_FASTCALL ZEND_UNSET_DIM_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_UNSET_DIM_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *container;
zval *offset;
zend_ulong hval;
ZVAL_DEREF(container);
}
SEPARATE_ZVAL_NOREF(container);
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ offset = opline->op2.zv;
if (IS_VAR != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
HashTable *ht = Z_ARRVAL_P(container);
zend_hash_index_del(ht, hval);
break;
case IS_STRING:
- if (IS_TMP_VAR != IS_CONST) {
+ if (IS_CONST != IS_CONST) {
if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
goto num_index_dim;
}
zend_error(E_WARNING, "Illegal offset type in unset");
break;
}
- zval_ptr_dtor_nogc(free_op2);
+
} else if (IS_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use object as array");
}
-//??? if (IS_TMP_VAR == IS_CONST) {
+//??? if (IS_CONST == IS_CONST) {
//??? zval_copy_ctor(offset);
//??? }
Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+
} else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
ZEND_VM_CONTINUE(); /* bailed out before */
} else {
- zval_ptr_dtor_nogc(free_op2);
+
}
if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_UNSET_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_UNSET_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *container;
zval *offset;
if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
}
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ offset = opline->op2.zv;
if (IS_VAR != IS_UNUSED) {
ZVAL_DEREF(container);
}
if (IS_VAR == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
if (Z_OBJ_HT_P(container)->unset_property) {
- Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+ Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
} else {
zend_error(E_NOTICE, "Trying to unset property of non-object");
}
}
- zval_ptr_dtor_nogc(free_op2);
+
if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *container;
int result;
zend_ulong hval;
SAVE_OPLINE();
container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ offset = opline->op2.zv;
if (IS_VAR != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
HashTable *ht = Z_ARRVAL_P(container);
isset_again:
if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
str = Z_STR_P(offset);
- if (IS_TMP_VAR != IS_CONST) {
+ if (IS_CONST != IS_CONST) {
if (ZEND_HANDLE_NUMERIC(str, hval)) {
goto num_index_prop;
}
result = 0;
if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
- if (IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) {
+ if (IS_CONST & (IS_CV|IS_VAR)) {
ZVAL_DEREF(offset);
}
if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
result = ((opline->extended_value & ZEND_ISSET) == 0);
}
- zval_ptr_dtor_nogc(free_op2);
ZVAL_BOOL(EX_VAR(opline->result.var), result);
zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *container;
int result;
zval *offset;
SAVE_OPLINE();
container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ offset = opline->op2.zv;
if (IS_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
- result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+ result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
} else {
zend_error(E_NOTICE, "Trying to check property of non-object");
result = 0;
result = ((opline->extended_value & ZEND_ISSET) == 0);
}
- zval_ptr_dtor_nogc(free_op2);
ZVAL_BOOL(EX_VAR(opline->result.var), result);
zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_YIELD_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INSTANCEOF_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+ zval *expr;
+ zend_bool result;
+
+ SAVE_OPLINE();
+ expr = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
+
+ if (Z_TYPE_P(expr) == IS_OBJECT) {
+ zend_class_entry *ce;
+
+ if (IS_CONST == IS_CONST) {
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ } else {
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, ZEND_FETCH_CLASS_NO_AUTOLOAD TSRMLS_CC);
+ if (UNEXPECTED(ce == NULL)) {
+ ZVAL_FALSE(EX_VAR(opline->result.var));
+ zval_ptr_dtor_nogc(free_op1);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+ }
+ } else {
+ ce = Z_CE_P(EX_VAR(opline->op2.var));
+ }
+ result = instanceof_function(Z_OBJCE_P(expr), ce TSRMLS_CC);
+ } else {
+ result = 0;
+ }
+ ZVAL_BOOL(EX_VAR(opline->result.var), result);
+ zval_ptr_dtor_nogc(free_op1);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_YIELD_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
}
/* Set the new yielded key */
- if (IS_TMP_VAR != IS_UNUSED) {
- zend_free_op free_op2;
- zval *key = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ if (IS_CONST != IS_UNUSED) {
+
+ zval *key = opline->op2.zv;
/* Consts, temporary variables and references need copying */
- if (IS_TMP_VAR == IS_CONST) {
+ if (IS_CONST == IS_CONST) {
ZVAL_DUP(&generator->key, key);
- } else if (IS_TMP_VAR == IS_TMP_VAR) {
+ } else if (IS_CONST == IS_TMP_VAR) {
ZVAL_COPY_VALUE(&generator->key, key);
- } else if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && Z_ISREF_P(key)) {
+ } else if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) && Z_ISREF_P(key)) {
ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
} else {
ZVAL_COPY_VALUE(&generator->key, key);
- if (IS_TMP_VAR == IS_CV) {
+ if (IS_CONST == IS_CV) {
if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
}
}
ZEND_VM_RETURN();
}
-static int ZEND_FASTCALL ZEND_POW_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_POW_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
SAVE_OPLINE();
pow_function(EX_VAR(opline->result.var),
_get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ opline->op2.zv TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
- zval_ptr_dtor_nogc(free_op2);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_binary_assign_op_helper_SPEC_VAR_TMP(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_VAR_CONST(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_MOD_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_MOD_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
SAVE_OPLINE();
fast_mod_function(EX_VAR(opline->result.var),
_get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_SL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
SAVE_OPLINE();
shift_left_function(EX_VAR(opline->result.var),
_get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_SR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
SAVE_OPLINE();
shift_right_function(EX_VAR(opline->result.var),
_get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_CONCAT_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_CONCAT_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
SAVE_OPLINE();
concat_function(EX_VAR(opline->result.var),
_get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_IS_IDENTICAL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_IS_IDENTICAL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
SAVE_OPLINE();
fast_is_identical_function(EX_VAR(opline->result.var),
_get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_IS_NOT_IDENTICAL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_IS_NOT_IDENTICAL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
SAVE_OPLINE();
fast_is_not_identical_function(result,
_get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_BW_OR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BW_OR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
SAVE_OPLINE();
bitwise_or_function(EX_VAR(opline->result.var),
_get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_BW_AND_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BW_AND_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
SAVE_OPLINE();
bitwise_and_function(EX_VAR(opline->result.var),
_get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_BW_XOR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BW_XOR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
SAVE_OPLINE();
bitwise_xor_function(EX_VAR(opline->result.var),
_get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_BOOL_XOR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BOOL_XOR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
SAVE_OPLINE();
boolean_xor_function(EX_VAR(opline->result.var),
_get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2, free_op_data1;
zval *object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- zval *property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ zval *property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
zval *value;
zval *zptr;
/* here we are sure we are dealing with an object */
if (opline->extended_value == ZEND_ASSIGN_OBJ
&& EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
ZVAL_DEREF(zptr);
SEPARATE_ZVAL_NOREF(zptr);
if (opline->extended_value == ZEND_ASSIGN_OBJ) {
if (Z_OBJ_HT_P(object)->read_property) {
- z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+ z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
}
} else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
if (Z_OBJ_HT_P(object)->read_dimension) {
SEPARATE_ZVAL_IF_NOT_REF(z);
binary_op(z, z, value TSRMLS_CC);
if (opline->extended_value == ZEND_ASSIGN_OBJ) {
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+ Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
} else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2, free_op_data1;
if (IS_VAR == IS_VAR && !(free_op1 != NULL)) {
Z_ADDREF_P(container); /* undo the effect of get_obj_zval_ptr_ptr() */
}
- return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else {
- zval *dim = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+ zval *dim = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- zend_fetch_dimension_address_RW(&rv, container, dim, IS_VAR TSRMLS_CC);
+ zend_fetch_dimension_address_RW(&rv, container, dim, IS_TMP_VAR TSRMLS_CC);
value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
var_ptr = Z_INDIRECT(rv);
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
zval *value;
SAVE_OPLINE();
- value = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+ value = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_VAR_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_VAR_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_VAR_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_VAR_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_VAR_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_VAR_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_VAR_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_VAR_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_VAR_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_VAR_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_VAR_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_VAR_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_VAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
- zval *object;
- zval *property;
- zval *retval;
- zval *zptr;
+ zval *container;
SAVE_OPLINE();
- object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- retval = EX_VAR(opline->result.var);
+ container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+ zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ zval_ptr_dtor_nogc(free_op1);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
+static int ZEND_FASTCALL ZEND_FETCH_DIM_W_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1, free_op2;
+ zval *container;
- if (IS_VAR != IS_UNUSED) {
- object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
- }
+ SAVE_OPLINE();
+ container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- zval_ptr_dtor_nogc(free_op2);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(retval);
- }
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ }
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- /* here we are sure we are dealing with an object */
-
- if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
-
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
-
- incdec_op(zptr);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(retval, zptr);
- }
- } else {
- zval rv;
-
- if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+static int ZEND_FASTCALL ZEND_FETCH_DIM_RW_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1, free_op2;
+ zval *container;
- if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
- zval rv;
- zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+ SAVE_OPLINE();
+ container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (Z_REFCOUNT_P(z) == 0) {
- zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
- }
- ZVAL_COPY_VALUE(z, value);
- }
- if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
- SEPARATE_ZVAL_IF_NOT_REF(z);
- incdec_op(z);
- ZVAL_COPY_VALUE(retval, z);
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
- SELECTIVE_PZVAL_LOCK(retval, opline);
- zval_ptr_dtor(z);
- } else {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(retval);
- }
- }
+ if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
-
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
zval_ptr_dtor_nogc(free_op2);
+ if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ }
if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_IS_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_pre_incdec_property_helper_SPEC_VAR_VAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ USE_OPLINE
+ zend_free_op free_op1, free_op2;
+ zval *container;
-static int ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_pre_incdec_property_helper_SPEC_VAR_VAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ SAVE_OPLINE();
+ container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+ zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ zval_ptr_dtor_nogc(free_op1);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_VAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *container;
zend_free_op free_op1, free_op2;
- zval *object;
- zval *property;
- zval *retval;
- zval *zptr;
SAVE_OPLINE();
- object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- retval = EX_VAR(opline->result.var);
- if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
+ if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+ if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
+ zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+ }
+ container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+ if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ }
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
+ if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ }
+ zval_ptr_dtor_nogc(free_op2);
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+ } else {
+ if (IS_TMP_VAR == IS_UNUSED) {
+ zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
+ }
+ container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+ zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ zval_ptr_dtor_nogc(free_op1);
}
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- if (IS_VAR != IS_UNUSED) {
- object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
- }
+static int ZEND_FASTCALL ZEND_FETCH_DIM_UNSET_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1, free_op2;
+ zval *container;
- if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- zval_ptr_dtor_nogc(free_op2);
- ZVAL_NULL(retval);
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ SAVE_OPLINE();
+ container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+
+ if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ }
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- /* here we are sure we are dealing with an object */
+static int ZEND_FASTCALL ZEND_ASSIGN_DIM_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+ zval *object_ptr;
- if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+ SAVE_OPLINE();
+ object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- ZVAL_DEREF(zptr);
- ZVAL_COPY_VALUE(retval, zptr);
- zval_opt_copy_ctor(zptr);
+ if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ }
+ ZVAL_DEREF(object_ptr);
+ if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
+ zend_free_op free_op2;
+ zval *property_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- incdec_op(zptr);
+ zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_VAR, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
} else {
- if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval rv;
- zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
- zval z_copy;
-
- if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
- zval rv;
- zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+ zend_free_op free_op2, free_op_data1;
+ zval rv;
+ zval *value;
+ zval *dim = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ zval *variable_ptr;
- if (Z_REFCOUNT_P(z) == 0) {
- zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
+ if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
+ EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
+ zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+ zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
+ FREE_OP(free_op_data1);
+ } else {
+ zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_TMP_VAR TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+ ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+ variable_ptr = Z_INDIRECT(rv);
+ if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
+ FREE_OP(free_op_data1);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
+ value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
+ if ((opline+1)->op1_type == IS_VAR) {
+ FREE_OP(free_op_data1);
+ }
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), value);
}
- ZVAL_COPY_VALUE(z, value);
}
- ZVAL_DUP(retval, z);
- ZVAL_DUP(&z_copy, z);
- incdec_op(&z_copy);
- if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
- Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
- zval_ptr_dtor(&z_copy);
- zval_ptr_dtor(z);
- } else {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- ZVAL_NULL(retval);
}
}
-
- zval_ptr_dtor_nogc(free_op2);
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+ /* assign_dim has two opcodes! */
CHECK_EXCEPTION();
+ ZEND_VM_INC_OPCODE();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_post_incdec_property_helper_SPEC_VAR_VAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ USE_OPLINE
+ zend_free_op free_op1, free_op2;
+ zval *value;
+ zval *variable_ptr;
-static int ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_post_incdec_property_helper_SPEC_VAR_VAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ SAVE_OPLINE();
+ value = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ variable_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+
+ if (IS_VAR == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
+ if (IS_TMP_VAR == IS_TMP_VAR) {
+ zval_ptr_dtor_nogc(free_op2);
+ }
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
+ value = zend_assign_to_variable(variable_ptr, value, IS_TMP_VAR TSRMLS_CC);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), value);
+ }
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+ }
+
+ /* zend_assign_to_variable() always takes care of op2, never free it! */
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_VAR_VAR(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_YIELD_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *varname;
- zval *retval;
- zend_string *name;
- HashTable *target_symbol_table;
- SAVE_OPLINE();
- varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+ /* The generator object is stored in EX(return_value) */
+ zend_generator *generator = (zend_generator *) EX(return_value);
- if (IS_VAR == IS_CONST) {
- name = Z_STR_P(varname);
- } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
- name = Z_STR_P(varname);
- zend_string_addref(name);
- } else {
- name = zval_get_string(varname);
+ if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
+ zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
}
+ /* Destroy the previously yielded value */
+ zval_ptr_dtor(&generator->value);
+
+ /* Destroy the previously yielded key */
+ zval_ptr_dtor(&generator->key);
+
+ /* Set the new yielded value */
if (IS_VAR != IS_UNUSED) {
- zend_class_entry *ce;
+ zend_free_op free_op1;
- if (IS_VAR == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
+ /* Constants and temporary variables aren't yieldable by reference,
+ * but we still allow them with a notice. */
+ if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
+ zval *value;
+
+ zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+
+ value = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+ ZVAL_COPY_VALUE(&generator->value, value);
+ if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
+
+ /* Temporary variables don't need ctor copying */
+ if (IS_VAR != IS_TMP_VAR) {
+ zval_opt_copy_ctor(&generator->value);
+ }
} else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- if (IS_VAR != IS_CONST) {
- zend_string_release(name);
- }
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ zval *value_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+
+ if (IS_VAR == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
}
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
- }
- retval = zend_std_get_static_property(ce, name, 0, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
- } else {
- target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- retval = zend_hash_find(target_symbol_table, name);
- if (retval == NULL) {
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_UNSET:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_IS:
- retval = &EG(uninitialized_zval);
- break;
- case BP_VAR_RW:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_W:
- retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
- }
- /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
- } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
- retval = Z_INDIRECT_P(retval);
- if (Z_TYPE_P(retval) == IS_UNDEF) {
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_UNSET:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_IS:
- retval = &EG(uninitialized_zval);
- break;
- case BP_VAR_RW:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_W:
- ZVAL_NULL(retval);
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
+
+ /* If a function call result is yielded and the function did
+ * not return by reference we throw a notice. */
+ if (IS_VAR == IS_VAR &&
+ (value_ptr == &EG(uninitialized_zval) ||
+ (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+ !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+ zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+ } else {
+ ZVAL_MAKE_REF(value_ptr);
}
- }
- }
- if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
- if (Z_CONSTANT_P(retval)) {
- zval_update_constant(retval, 1 TSRMLS_CC);
- }
- } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
- zval_ptr_dtor_nogc(free_op1);
- }
- }
+ ZVAL_COPY(&generator->value, value_ptr);
- if (IS_VAR != IS_CONST) {
- zend_string_release(name);
- }
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+ }
+ } else {
+ zval *value = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- ZEND_ASSERT(retval != NULL);
- if (type == BP_VAR_R || type == BP_VAR_IS) {
- if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
- ZVAL_UNREF(retval);
+ /* Consts, temporary variables and references need copying */
+ if (IS_VAR == IS_CONST) {
+ ZVAL_DUP(&generator->value, value);
+ } else if (IS_VAR == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&generator->value, value);
+ } else if ((IS_VAR == IS_CV || IS_VAR == IS_VAR) && Z_ISREF_P(value)) {
+ ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
+ zval_ptr_dtor_nogc(free_op1);
+ } else {
+ ZVAL_COPY_VALUE(&generator->value, value);
+ if (IS_VAR == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+ }
+ }
}
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
} else {
- ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
+ /* If no value was specified yield null */
+ ZVAL_NULL(&generator->value);
}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-static int ZEND_FASTCALL ZEND_FETCH_R_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_VAR_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ /* Set the new yielded key */
+ if (IS_TMP_VAR != IS_UNUSED) {
+ zend_free_op free_op2;
+ zval *key = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-static int ZEND_FASTCALL ZEND_FETCH_W_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_VAR_VAR(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ /* Consts, temporary variables and references need copying */
+ if (IS_TMP_VAR == IS_CONST) {
+ ZVAL_DUP(&generator->key, key);
+ } else if (IS_TMP_VAR == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&generator->key, key);
+ } else if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && Z_ISREF_P(key)) {
+ ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
-static int ZEND_FASTCALL ZEND_FETCH_RW_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_VAR_VAR(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ } else {
+ ZVAL_COPY_VALUE(&generator->key, key);
+ if (IS_TMP_VAR == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
+ }
+ }
-static int ZEND_FASTCALL ZEND_FETCH_FUNC_ARG_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ if (Z_TYPE(generator->key) == IS_LONG
+ && Z_LVAL(generator->key) > generator->largest_used_integer_key
+ ) {
+ generator->largest_used_integer_key = Z_LVAL(generator->key);
+ }
+ } else {
+ /* If no key was specified we use auto-increment keys */
+ generator->largest_used_integer_key++;
+ ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
+ }
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- return zend_fetch_var_address_helper_SPEC_VAR_VAR(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ if (RETURN_VALUE_USED(opline)) {
+ /* If the return value of yield is used set the send
+ * target and initialize it to NULL */
+ generator->send_target = EX_VAR(opline->result.var);
+ ZVAL_NULL(generator->send_target);
} else {
- return zend_fetch_var_address_helper_SPEC_VAR_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ generator->send_target = NULL;
}
-}
-static int ZEND_FASTCALL ZEND_FETCH_UNSET_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_VAR_VAR(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ /* We increment to the next op, so we are at the correct position when the
+ * generator is resumed. */
+ ZEND_VM_INC_OPCODE();
-static int ZEND_FASTCALL ZEND_FETCH_IS_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_VAR_VAR(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ /* The GOTO VM uses a local opline variable. We need to set the opline
+ * variable in execute_data so we don't resume at an old position. */
+ SAVE_OPLINE();
+
+ ZEND_VM_RETURN();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_POW_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
- zval *container;
SAVE_OPLINE();
- container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ pow_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
+ zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_W_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *container;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ return zend_binary_assign_op_helper_SPEC_VAR_TMP(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_RW_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_MOD_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
- zval *container;
SAVE_OPLINE();
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+ fast_mod_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
zval_ptr_dtor_nogc(free_op2);
- if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_IS_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
- zval *container;
SAVE_OPLINE();
- container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ shift_left_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
+ zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *container;
zend_free_op free_op1, free_op2;
SAVE_OPLINE();
-
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
- zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
- }
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
- if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
- zval_ptr_dtor_nogc(free_op2);
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- } else {
- if (IS_VAR == IS_UNUSED) {
- zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
- }
- container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- zval_ptr_dtor_nogc(free_op1);
- }
+ shift_right_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
+ zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_UNSET_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_CONCAT_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
- zval *container;
SAVE_OPLINE();
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+ concat_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
zval_ptr_dtor_nogc(free_op2);
- if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_IS_IDENTICAL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *container;
- zend_free_op free_op2;
- zval *offset;
+ zend_free_op free_op1, free_op2;
SAVE_OPLINE();
- container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
- if ((IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
- UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
- zend_error(E_NOTICE, "Trying to get property of non-object");
- ZVAL_NULL(EX_VAR(opline->result.var));
- } else {
- zval *retval;
-
- /* here we are sure we are dealing with an object */
- do {
- if (IS_VAR == IS_CONST &&
- EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
- zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
- zend_object *zobj = Z_OBJ_P(container);
-
- if (EXPECTED(prop_info)) {
- retval = OBJ_PROP(zobj, prop_info->offset);
- if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- } else if (EXPECTED(zobj->properties != NULL)) {
- retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
- if (EXPECTED(retval)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- }
- }
-
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
-
- if (retval != EX_VAR(opline->result.var)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- }
- } while (0);
- }
-
- zval_ptr_dtor_nogc(free_op2);
+ fast_is_identical_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
+ zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_W_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_IS_NOT_IDENTICAL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
- zval *property;
- zval *container;
+ zval *result = EX_VAR(opline->result.var);
SAVE_OPLINE();
- property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
-
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+ fast_is_not_identical_function(result,
+ _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
zval_ptr_dtor_nogc(free_op2);
- if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_RW_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BW_OR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
- zval *property;
- zval *container;
SAVE_OPLINE();
- property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
+ bitwise_or_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
zval_ptr_dtor_nogc(free_op2);
- if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BW_AND_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *container;
- zend_free_op free_op2;
- zval *offset;
+ zend_free_op free_op1, free_op2;
SAVE_OPLINE();
- container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
- if ((IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
- UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- } else {
- zval *retval;
-
- /* here we are sure we are dealing with an object */
- do {
- if (IS_VAR == IS_CONST &&
- EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
- zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
- zend_object *zobj = Z_OBJ_P(container);
-
- if (EXPECTED(prop_info)) {
- retval = OBJ_PROP(zobj, prop_info->offset);
- if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- } else if (EXPECTED(zobj->properties != NULL)) {
- retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
- if (EXPECTED(retval)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- }
- }
-
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
-
- if (retval != EX_VAR(opline->result.var)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- }
- } while (0);
- }
-
- zval_ptr_dtor_nogc(free_op2);
+ bitwise_and_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op1);
+ zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *container;
-
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- /* Behave like FETCH_OBJ_W */
- zend_free_op free_op1, free_op2;
- zval *property;
-
- SAVE_OPLINE();
- property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
- zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
- }
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- } else {
- return ZEND_FETCH_OBJ_R_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_UNSET_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BW_XOR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
- zval *container, *property;
SAVE_OPLINE();
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
+ bitwise_xor_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
zval_ptr_dtor_nogc(free_op2);
- if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BOOL_XOR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
- zval *object;
- zval *property_name;
SAVE_OPLINE();
- object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- property_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
- if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_VAR, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+ boolean_xor_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
zval_ptr_dtor_nogc(free_op2);
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- /* assign_obj has two opcodes! */
CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_DIM_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *object_ptr;
+ zend_free_op free_op1, free_op2, free_op_data1;
+ zval *object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+ zval *property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ zval *value;
+ zval *zptr;
- SAVE_OPLINE();
- object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+ if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+ }
- if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ if (IS_VAR != IS_UNUSED) {
+ object = make_real_object(object TSRMLS_CC);
}
- ZVAL_DEREF(object_ptr);
- if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
- zend_free_op free_op2;
- zval *property_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_VAR, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+ value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+
+ if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ zend_error(E_WARNING, "Attempt to assign property of non-object");
zval_ptr_dtor_nogc(free_op2);
+ FREE_OP(free_op_data1);
+
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
} else {
- zend_free_op free_op2, free_op_data1;
- zval rv;
- zval *value;
- zval *dim = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
- zval *variable_ptr;
+ /* here we are sure we are dealing with an object */
+ if (opline->extended_value == ZEND_ASSIGN_OBJ
+ && EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
- if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
- EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
- zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
- FREE_OP(free_op_data1);
+ ZVAL_DEREF(zptr);
+ SEPARATE_ZVAL_NOREF(zptr);
+
+ binary_op(zptr, zptr, value TSRMLS_CC);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), zptr);
+ }
} else {
- zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
- variable_ptr = Z_INDIRECT(rv);
- if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
- FREE_OP(free_op_data1);
+ zval *z = NULL;
+ zval rv;
+
+ if (opline->extended_value == ZEND_ASSIGN_OBJ) {
+ if (Z_OBJ_HT_P(object)->read_property) {
+ z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+ }
+ } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
+ if (Z_OBJ_HT_P(object)->read_dimension) {
+ z = Z_OBJ_HT_P(object)->read_dimension(object, property, BP_VAR_R, &rv TSRMLS_CC);
+ }
+ }
+ if (z) {
+ if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+ zval rv;
+ zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+
+ if (Z_REFCOUNT_P(z) == 0) {
+ zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
+ }
+ ZVAL_COPY_VALUE(z, value);
+ }
+//??? if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
+ SEPARATE_ZVAL_IF_NOT_REF(z);
+ binary_op(z, z, value TSRMLS_CC);
+ if (opline->extended_value == ZEND_ASSIGN_OBJ) {
+ Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+ } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
+ Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
+ }
if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
+ ZVAL_COPY(EX_VAR(opline->result.var), z);
}
+ zval_ptr_dtor(z);
} else {
- value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
- if ((opline+1)->op1_type == IS_VAR) {
- FREE_OP(free_op_data1);
- }
+ zend_error(E_WARNING, "Attempt to assign property of non-object");
if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), value);
+ ZVAL_NULL(EX_VAR(opline->result.var));
}
}
}
+
+ zval_ptr_dtor_nogc(free_op2);
+ FREE_OP(free_op_data1);
}
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- /* assign_dim has two opcodes! */
+
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+ /* assign_obj has two opcodes! */
CHECK_EXCEPTION();
ZEND_VM_INC_OPCODE();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *value;
- zval *variable_ptr;
+ zend_free_op free_op1, free_op2, free_op_data1;
+ zval *var_ptr, rv;
+ zval *value, *container;
SAVE_OPLINE();
- value = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
- variable_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
- if (IS_VAR == IS_TMP_VAR) {
- zval_ptr_dtor_nogc(free_op2);
+ container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+ if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ }
+ if (IS_VAR != IS_UNUSED) {
+ ZVAL_DEREF(container);
+ }
+ if (IS_VAR == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ if (IS_VAR == IS_VAR && !(free_op1 != NULL)) {
+ Z_ADDREF_P(container); /* undo the effect of get_obj_zval_ptr_ptr() */
}
- if (RETURN_VALUE_USED(opline)) {
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else {
+ zval *dim = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+
+ zend_fetch_dimension_address_RW(&rv, container, dim, IS_VAR TSRMLS_CC);
+ value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+ ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+ var_ptr = Z_INDIRECT(rv);
+ }
+
+ if (UNEXPECTED(var_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
+ }
+
+ if (UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
ZVAL_NULL(EX_VAR(opline->result.var));
}
} else {
- value = zend_assign_to_variable(variable_ptr, value, IS_VAR TSRMLS_CC);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), value);
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
+
+ binary_op(var_ptr, var_ptr, value TSRMLS_CC);
+
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
}
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
}
- /* zend_assign_to_variable() always takes care of op2, never free it! */
- zval_ptr_dtor_nogc(free_op2);
-
+ zval_ptr_dtor_nogc(free_op2);
+ FREE_OP(free_op_data1);
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
+ ZEND_VM_INC_OPCODE();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_REF_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
- zval *variable_ptr;
- zval *value_ptr;
+ zval *var_ptr;
+ zval *value;
SAVE_OPLINE();
- value_ptr = _get_zval_ptr_ptr_var(opline->op2.var, execute_data, &free_op2);
+ value = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+ var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (IS_VAR == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
- }
- if (IS_VAR == IS_VAR &&
- (value_ptr == &EG(uninitialized_zval) ||
- (opline->extended_value == ZEND_RETURNS_FUNCTION &&
- !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
- if (!(free_op2 != NULL)) {
- PZVAL_LOCK(value_ptr); /* undo the effect of get_zval_ptr_ptr() */
- }
- zend_error(E_STRICT, "Only variables should be assigned by reference");
- if (UNEXPECTED(EG(exception) != NULL)) {
- if (free_op2) {zval_ptr_dtor_nogc(free_op2);};
- HANDLE_EXCEPTION();
- }
- return ZEND_ASSIGN_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (IS_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
- if (!(free_op2 != NULL)) {
- PZVAL_LOCK(value_ptr);
- }
+ if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
}
- variable_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (IS_VAR == IS_VAR && UNEXPECTED(variable_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
- }
- if (IS_VAR == IS_VAR &&
- UNEXPECTED(Z_TYPE_P(EX_VAR(opline->op1.var)) != IS_INDIRECT) &&
- UNEXPECTED(!Z_ISREF_P(variable_ptr))) {
- zend_error_noreturn(E_ERROR, "Cannot assign by reference to overloaded object");
- }
- if ((IS_VAR == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) ||
- (IS_VAR == IS_VAR && UNEXPECTED(value_ptr == &EG(error_zval)))) {
- variable_ptr = &EG(uninitialized_zval);
+ if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
} else {
- zend_assign_to_variable_reference(variable_ptr, value_ptr TSRMLS_CC);
- }
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
- if (IS_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
- if (!(free_op2 != NULL)) {
- Z_DELREF_P(variable_ptr);
- }
- }
+ binary_op(var_ptr, var_ptr, value TSRMLS_CC);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), variable_ptr);
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+ }
}
+ zval_ptr_dtor_nogc(free_op2);
if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- if (free_op2) {zval_ptr_dtor_nogc(free_op2);};
-
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *function_name;
- zend_free_op free_op1, free_op2;
- zval *object;
- zend_function *fbc;
- zend_class_entry *called_scope;
- zend_object *obj;
-
- SAVE_OPLINE();
-
- function_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_VAR != IS_CONST &&
- UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- zend_error_noreturn(E_ERROR, "Method name must be a string");
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_VAR_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
+}
- object = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- uint32_t nesting = 1;
-
- if (UNEXPECTED(EG(exception) != NULL)) {
- zval_ptr_dtor_nogc(free_op2);
- HANDLE_EXCEPTION();
- }
-
- zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s", Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
- zval_ptr_dtor_nogc(free_op2);
- zval_ptr_dtor_nogc(free_op1);
-
- if (EG(exception) != NULL) {
- HANDLE_EXCEPTION();
- }
-
- /* No exception raised: Skip over arguments until fcall opcode with correct
- * nesting level. Return NULL (except when return value unused) */
- do {
- opline++;
- if (opline->opcode == ZEND_INIT_FCALL ||
- opline->opcode == ZEND_INIT_FCALL_BY_NAME ||
- opline->opcode == ZEND_INIT_NS_FCALL_BY_NAME ||
- opline->opcode == ZEND_INIT_METHOD_CALL ||
- opline->opcode == ZEND_INIT_STATIC_METHOD_CALL ||
- opline->opcode == ZEND_INIT_USER_CALL ||
- opline->opcode == ZEND_NEW
- ) {
- nesting++;
- } else if (opline->opcode == ZEND_DO_FCALL) {
- nesting--;
- }
- } while (nesting);
-
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
+static int ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- /* We've skipped EXT_FCALL_BEGIND, so also skip the ending opcode */
- if ((opline + 1)->opcode == ZEND_EXT_FCALL_END) {
- opline++;
- }
- ZEND_VM_JMP(++opline);
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_VAR_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
+}
- obj = Z_OBJ_P(object);
- called_scope = obj->ce;
-
- if (IS_VAR != IS_CONST ||
- EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
- zend_object *orig_obj = obj;
-
- if (UNEXPECTED(obj->handlers->get_method == NULL)) {
- zend_error_noreturn(E_ERROR, "Object does not support method calls");
- }
-
- /* First, locate the function. */
- fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_VAR == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
- if (UNEXPECTED(fbc == NULL)) {
- zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
- }
- if (IS_VAR == IS_CONST &&
- EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
- EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
- EXPECTED(obj == orig_obj)) {
- CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope, fbc);
- }
- }
+static int ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_STATIC) != 0)) {
- obj = NULL;
- } else {
- GC_REFCOUNT(obj)++; /* For $this pointer */
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_VAR_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
+}
- EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
- fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
-
- zval_ptr_dtor_nogc(free_op2);
- zval_ptr_dtor_nogc(free_op1);
+static int ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_VAR_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
}
-static int ZEND_FASTCALL ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *function_name;
- zend_class_entry *ce;
- zend_object *object;
- zend_function *fbc;
-
- SAVE_OPLINE();
- if (IS_VAR == IS_CONST) {
- /* no function found. try a static method in class */
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op1.zv), opline->op1.zv + 1, ZEND_FETCH_CLASS_DEFAULT TSRMLS_CC);
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- if (UNEXPECTED(ce == NULL)) {
- zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op1.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op1.var));
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_VAR_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
+}
- if (IS_VAR == IS_CONST &&
- IS_VAR == IS_CONST &&
- CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- fbc = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else if (IS_VAR != IS_CONST &&
- IS_VAR == IS_CONST &&
- (fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce))) {
- /* do nothing */
- } else if (IS_VAR != IS_UNUSED) {
- zend_free_op free_op2;
-
- function_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_VAR != IS_CONST) {
- if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- zend_error_noreturn(E_ERROR, "Function name must be a string");
- }
- }
+static int ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- if (ce->get_static_method) {
- fbc = ce->get_static_method(ce, Z_STR_P(function_name) TSRMLS_CC);
- } else {
- fbc = zend_std_get_static_method(ce, Z_STR_P(function_name), ((IS_VAR == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
- }
- if (UNEXPECTED(fbc == NULL)) {
- zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name->val, Z_STRVAL_P(function_name));
- }
- if (IS_VAR == IS_CONST &&
- EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
- EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0)) {
- if (IS_VAR == IS_CONST) {
- CACHE_PTR(Z_CACHE_SLOT_P(function_name), fbc);
- } else {
- CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), ce, fbc);
- }
- }
- if (IS_VAR != IS_CONST) {
- zval_ptr_dtor_nogc(free_op2);
- }
- } else {
- if (UNEXPECTED(ce->constructor == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot call constructor");
- }
- if (Z_OBJ(EX(This)) && Z_OBJ(EX(This))->ce != ce->constructor->common.scope && (ce->constructor->common.fn_flags & ZEND_ACC_PRIVATE)) {
- zend_error_noreturn(E_ERROR, "Cannot call private %s::__construct()", ce->name->val);
- }
- fbc = ce->constructor;
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_VAR_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
+}
- object = NULL;
- if (!(fbc->common.fn_flags & ZEND_ACC_STATIC)) {
- if (Z_OBJ(EX(This))) {
- object = Z_OBJ(EX(This));
- GC_REFCOUNT(object)++;
- }
- if (!object ||
- !instanceof_function(object->ce, ce TSRMLS_CC)) {
- /* We are calling method of the other (incompatible) class,
- but passing $this. This is done for compatibility with php-4. */
- if (fbc->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
- zend_error(
- object ? E_DEPRECATED : E_STRICT,
- "Non-static method %s::%s() should not be called statically%s",
- fbc->common.scope->name->val, fbc->common.function_name->val,
- object ? ", assuming $this from incompatible context" : "");
- } else {
- /* An internal function assumes $this is present and won't check that. So PHP would crash by allowing the call. */
- zend_error_noreturn(
- E_ERROR,
- "Non-static method %s::%s() cannot be called statically%s",
- fbc->common.scope->name->val, fbc->common.function_name->val,
- object ? ", assuming $this from incompatible context" : "");
- }
- }
- }
+static int ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- if (IS_VAR != IS_CONST) {
- /* previous opcode is ZEND_FETCH_CLASS */
- if ((opline-1)->extended_value == ZEND_FETCH_CLASS_PARENT || (opline-1)->extended_value == ZEND_FETCH_CLASS_SELF) {
- ce = EX(called_scope);
- }
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_VAR_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
+}
- EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
- fbc, opline->extended_value, ce, object, EX(call) TSRMLS_CC);
+static int ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- if (IS_VAR == IS_UNUSED) {
- EX(call)->return_value = NULL;
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_VAR_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_CASE_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *result = EX_VAR(opline->result.var);
-
- SAVE_OPLINE();
- fast_equal_function(result,
- _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_VAR_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
}
-static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *expr_ptr, new_expr;
- SAVE_OPLINE();
- if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) &&
- (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
- expr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (IS_VAR == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
- }
- ZVAL_MAKE_REF(expr_ptr);
- Z_ADDREF_P(expr_ptr);
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
- } else {
- expr_ptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (IS_VAR == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&new_expr, expr_ptr);
- expr_ptr = &new_expr;
- } else if (IS_VAR == IS_CONST) {
- if (!Z_IMMUTABLE_P(expr_ptr)) {
- ZVAL_DUP(&new_expr, expr_ptr);
- expr_ptr = &new_expr;
- }
- } else if ((IS_VAR == IS_CV || IS_VAR == IS_VAR) && Z_ISREF_P(expr_ptr)) {
- expr_ptr = Z_REFVAL_P(expr_ptr);
- if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
- zval_ptr_dtor_nogc(free_op1);
- } else if (IS_VAR == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
- Z_ADDREF_P(expr_ptr);
- }
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_VAR_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
+}
- if (IS_VAR != IS_UNUSED) {
- zend_free_op free_op2;
- zval *offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- zend_string *str;
- zend_ulong hval;
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
-add_again:
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- goto num_index;
- case IS_LONG:
- hval = Z_LVAL_P(offset);
-num_index:
- zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
- break;
- case IS_STRING:
- str = Z_STR_P(offset);
- if (IS_VAR != IS_CONST) {
- if (ZEND_HANDLE_NUMERIC(str, hval)) {
- goto num_index;
- }
- }
-str_index:
- zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
- break;
- case IS_NULL:
- str = STR_EMPTY_ALLOC();
- goto str_index;
- case IS_FALSE:
- hval = 0;
- goto num_index;
- case IS_TRUE:
- hval = 1;
- goto num_index;
- case IS_REFERENCE:
- offset = Z_REFVAL_P(offset);
- goto add_again;
- break;
- default:
- zend_error(E_WARNING, "Illegal offset type");
- zval_ptr_dtor(expr_ptr);
- /* do nothing */
- break;
- }
- zval_ptr_dtor_nogc(free_op2);
- } else {
- zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_VAR_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
+}
+
+static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1, free_op2;
+ zval *container;
+
+ SAVE_OPLINE();
+ container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+ zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_W_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- zval *array;
- uint32_t size;
USE_OPLINE
+ zend_free_op free_op1, free_op2;
+ zval *container;
- array = EX_VAR(opline->result.var);
- if (IS_VAR != IS_UNUSED) {
- size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
- } else {
- size = 0;
- }
- ZVAL_NEW_ARR(array);
- zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
+ SAVE_OPLINE();
+ container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (IS_VAR != IS_UNUSED) {
- /* Explicitly initialize array as not-packed if flag is set */
- if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
- zend_hash_real_init(Z_ARRVAL_P(array), 0);
- }
+ if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
-
- if (IS_VAR == IS_UNUSED) {
- ZEND_VM_NEXT_OPCODE();
-#if 0 || IS_VAR != IS_UNUSED
- } else {
- return ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-#endif
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_UNSET_VAR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_RW_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval tmp, *varname;
- HashTable *target_symbol_table;
- zend_free_op free_op1;
+ zend_free_op free_op1, free_op2;
+ zval *container;
SAVE_OPLINE();
- if (IS_VAR == IS_CV &&
- IS_VAR == IS_UNUSED &&
- (opline->extended_value & ZEND_QUICK_SET)) {
- zval *var = EX_VAR(opline->op1.var);
-
- if (Z_REFCOUNTED_P(var)) {
- zend_refcounted *garbage = Z_COUNTED_P(var);
+ container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (!--GC_REFCOUNT(garbage)) {
- ZVAL_UNDEF(var);
- _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
- } else {
- GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
- ZVAL_UNDEF(var);
- }
- } else {
- ZVAL_UNDEF(var);
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
-
- varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- ZVAL_UNDEF(&tmp);
- if (IS_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
- ZVAL_STR(&tmp, zval_get_string(varname));
- varname = &tmp;
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- if (IS_VAR != IS_UNUSED) {
- zend_class_entry *ce;
-
- if (IS_VAR == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(EG(exception) != NULL)) {
- if (IS_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
- }
- zval_ptr_dtor_nogc(free_op1);
- HANDLE_EXCEPTION();
- }
- if (UNEXPECTED(ce == NULL)) {
- zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
- }
- zend_std_unset_static_property(ce, Z_STR_P(varname), ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
- } else {
- target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
- }
+static int ZEND_FASTCALL ZEND_FETCH_DIM_IS_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1, free_op2;
+ zval *container;
- if (IS_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
- }
+ SAVE_OPLINE();
+ container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+ zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_UNSET_DIM_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
zval *container;
- zval *offset;
- zend_ulong hval;
+ zend_free_op free_op1, free_op2;
SAVE_OPLINE();
- container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
- }
- if (IS_VAR != IS_UNUSED) {
- ZVAL_DEREF(container);
- }
- SEPARATE_ZVAL_NOREF(container);
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_VAR != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
- HashTable *ht = Z_ARRVAL_P(container);
-offset_again:
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- zend_hash_index_del(ht, hval);
- break;
- case IS_LONG:
- hval = Z_LVAL_P(offset);
-num_index_dim:
- zend_hash_index_del(ht, hval);
- break;
- case IS_STRING:
- if (IS_VAR != IS_CONST) {
- if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
- goto num_index_dim;
- }
- }
- if (ht == &EG(symbol_table).ht) {
- zend_delete_global_variable(Z_STR_P(offset) TSRMLS_CC);
- } else {
- zend_hash_del(ht, Z_STR_P(offset));
- }
- break;
- case IS_NULL:
- zend_hash_del(ht, STR_EMPTY_ALLOC());
- break;
- case IS_FALSE:
- hval = 0;
- goto num_index_dim;
- case IS_TRUE:
- hval = 1;
- goto num_index_dim;
- case IS_RESOURCE:
- hval = Z_RES_HANDLE_P(offset);
- goto num_index_dim;
- case IS_REFERENCE:
- offset = Z_REFVAL_P(offset);
- goto offset_again;
- break;
- default:
- zend_error(E_WARNING, "Illegal offset type in unset");
- break;
+ if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+ if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
+ zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+ }
+ container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+ if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
- zval_ptr_dtor_nogc(free_op2);
- } else if (IS_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use object as array");
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+ if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
-//??? if (IS_VAR == IS_CONST) {
-//??? zval_copy_ctor(offset);
-//??? }
- Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
zval_ptr_dtor_nogc(free_op2);
- } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
- ZEND_VM_CONTINUE(); /* bailed out before */
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
} else {
+ if (IS_VAR == IS_UNUSED) {
+ zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
+ }
+ container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+ zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
zval_ptr_dtor_nogc(free_op2);
+ zval_ptr_dtor_nogc(free_op1);
}
- if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_UNSET_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_UNSET_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
zval *container;
- zval *offset;
SAVE_OPLINE();
container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
- }
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_VAR != IS_UNUSED) {
- ZVAL_DEREF(container);
- }
- if (IS_VAR == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
- if (Z_OBJ_HT_P(container)->unset_property) {
- Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to unset property of non-object");
- }
+ if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
zval_ptr_dtor_nogc(free_op2);
+ if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ }
if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_VAR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_DIM_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *value;
+ zend_free_op free_op1;
+ zval *object_ptr;
SAVE_OPLINE();
- if (IS_VAR == IS_CV &&
- IS_VAR == IS_UNUSED &&
- (opline->extended_value & ZEND_QUICK_SET)) {
- value = EX_VAR(opline->op1.var);
- if (opline->extended_value & ZEND_ISSET) {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- !i_zend_is_true(value TSRMLS_CC));
- CHECK_EXCEPTION();
- }
- ZEND_VM_NEXT_OPCODE();
- } else {
- zend_free_op free_op1;
- zval tmp, *varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+ object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- ZVAL_UNDEF(&tmp);
- if (IS_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
- ZVAL_STR(&tmp, zval_get_string(varname));
- varname = &tmp;
- }
+ if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ }
+ ZVAL_DEREF(object_ptr);
+ if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
+ zend_free_op free_op2;
+ zval *property_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_VAR != IS_UNUSED) {
- zend_class_entry *ce;
+ zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_VAR, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ } else {
+ zend_free_op free_op2, free_op_data1;
+ zval rv;
+ zval *value;
+ zval *dim = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+ zval *variable_ptr;
- if (IS_VAR == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+ if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
+ EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
+ zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+ zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
+ FREE_OP(free_op_data1);
+ } else {
+ zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_VAR TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+ ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+ variable_ptr = Z_INDIRECT(rv);
+ if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
+ FREE_OP(free_op_data1);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
}
} else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
+ value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
+ if ((opline+1)->op1_type == IS_VAR) {
+ FREE_OP(free_op_data1);
+ }
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), value);
+ }
}
- value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
- } else {
- HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
- }
-
- if (IS_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
- }
- zval_ptr_dtor_nogc(free_op1);
-
- if (opline->extended_value & ZEND_ISSET) {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- value && Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- !value || !i_zend_is_true(value TSRMLS_CC));
}
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
}
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+ /* assign_dim has two opcodes! */
+ CHECK_EXCEPTION();
+ ZEND_VM_INC_OPCODE();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
- zval *container;
- int result;
- zend_ulong hval;
- zval *offset;
+ zval *value;
+ zval *variable_ptr;
SAVE_OPLINE();
- container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
- if (IS_VAR != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
- HashTable *ht = Z_ARRVAL_P(container);
- zval *value;
- zend_string *str;
-
-isset_again:
- if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
- str = Z_STR_P(offset);
- if (IS_VAR != IS_CONST) {
- if (ZEND_HANDLE_NUMERIC(str, hval)) {
- goto num_index_prop;
- }
- }
-str_index_prop:
- value = zend_hash_find_ind(ht, str);
- } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
- hval = Z_LVAL_P(offset);
-num_index_prop:
- value = zend_hash_index_find(ht, hval);
- } else {
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- goto num_index_prop;
- case IS_NULL:
- str = STR_EMPTY_ALLOC();
- goto str_index_prop;
- case IS_FALSE:
- hval = 0;
- goto num_index_prop;
- case IS_TRUE:
- hval = 1;
- goto num_index_prop;
- case IS_RESOURCE:
- hval = Z_RES_HANDLE_P(offset);
- goto num_index_prop;
- case IS_REFERENCE:
- offset = Z_REFVAL_P(offset);
- goto isset_again;
- default:
- zend_error(E_WARNING, "Illegal offset type in isset or empty");
- value = NULL;
- break;
- }
- }
-
- if (opline->extended_value & ZEND_ISSET) {
- /* > IS_NULL means not IS_UNDEF and not IS_NULL */
- result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
- }
- } else if (IS_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
- result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to check element of non-array");
- result = 0;
- }
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
- }
- } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
- zval tmp;
+ value = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+ variable_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- result = 0;
- if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
- if (IS_VAR == IS_CV || IS_VAR == IS_VAR) {
- ZVAL_DEREF(offset);
- }
- if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
- || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
- && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
- ZVAL_DUP(&tmp, offset);
- convert_to_long(&tmp);
- offset = &tmp;
- }
- }
- if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
- if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
- if ((opline->extended_value & ZEND_ISSET) ||
- Z_STRVAL_P(container)[offset->value.lval] != '0') {
- result = 1;
- }
- }
+ if (IS_VAR == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
+ if (IS_VAR == IS_TMP_VAR) {
+ zval_ptr_dtor_nogc(free_op2);
}
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
}
} else {
- result = ((opline->extended_value & ZEND_ISSET) == 0);
+ value = zend_assign_to_variable(variable_ptr, value, IS_VAR TSRMLS_CC);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), value);
+ }
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
}
- zval_ptr_dtor_nogc(free_op2);
- ZVAL_BOOL(EX_VAR(opline->result.var), result);
- zval_ptr_dtor_nogc(free_op1);
+ /* zend_assign_to_variable() always takes care of op2, never free it! */
+ zval_ptr_dtor_nogc(free_op2);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_REF_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1, free_op2;
- zval *container;
- int result;
- zval *offset;
+ zval *variable_ptr;
+ zval *value_ptr;
SAVE_OPLINE();
- container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ value_ptr = _get_zval_ptr_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
- result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to check property of non-object");
- result = 0;
+ if (IS_VAR == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
+ }
+ if (IS_VAR == IS_VAR &&
+ (value_ptr == &EG(uninitialized_zval) ||
+ (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+ !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+ if (!(free_op2 != NULL)) {
+ PZVAL_LOCK(value_ptr); /* undo the effect of get_zval_ptr_ptr() */
}
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
+ zend_error(E_STRICT, "Only variables should be assigned by reference");
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ if (free_op2) {zval_ptr_dtor_nogc(free_op2);};
+ HANDLE_EXCEPTION();
+ }
+ return ZEND_ASSIGN_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (IS_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
+ if (!(free_op2 != NULL)) {
+ PZVAL_LOCK(value_ptr);
}
+ }
+
+ variable_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+ if (IS_VAR == IS_VAR && UNEXPECTED(variable_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
+ }
+ if (IS_VAR == IS_VAR &&
+ UNEXPECTED(Z_TYPE_P(EX_VAR(opline->op1.var)) != IS_INDIRECT) &&
+ UNEXPECTED(!Z_ISREF_P(variable_ptr))) {
+ zend_error_noreturn(E_ERROR, "Cannot assign by reference to overloaded object");
+ }
+ if ((IS_VAR == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) ||
+ (IS_VAR == IS_VAR && UNEXPECTED(value_ptr == &EG(error_zval)))) {
+ variable_ptr = &EG(uninitialized_zval);
} else {
- result = ((opline->extended_value & ZEND_ISSET) == 0);
+ zend_assign_to_variable_reference(variable_ptr, value_ptr TSRMLS_CC);
}
- zval_ptr_dtor_nogc(free_op2);
- ZVAL_BOOL(EX_VAR(opline->result.var), result);
- zval_ptr_dtor_nogc(free_op1);
+ if (IS_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
+ if (!(free_op2 != NULL)) {
+ Z_DELREF_P(variable_ptr);
+ }
+ }
+
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), variable_ptr);
+ }
+
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+ if (free_op2) {zval_ptr_dtor_nogc(free_op2);};
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
}
}
-static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_VAR_UNUSED(int type, ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *varname;
- zval *retval;
- zend_string *name;
- HashTable *target_symbol_table;
-
- SAVE_OPLINE();
- varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- if (IS_VAR == IS_CONST) {
- name = Z_STR_P(varname);
- } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
- name = Z_STR_P(varname);
- zend_string_addref(name);
- } else {
- name = zval_get_string(varname);
- }
-
- if (IS_UNUSED != IS_UNUSED) {
- zend_class_entry *ce;
-
- if (IS_UNUSED == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- if (IS_VAR != IS_CONST) {
- zend_string_release(name);
- }
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
- }
- retval = zend_std_get_static_property(ce, name, 0, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
- } else {
- target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- retval = zend_hash_find(target_symbol_table, name);
- if (retval == NULL) {
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_UNSET:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_IS:
- retval = &EG(uninitialized_zval);
- break;
- case BP_VAR_RW:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_W:
- retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
- }
- /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
- } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
- retval = Z_INDIRECT_P(retval);
- if (Z_TYPE_P(retval) == IS_UNDEF) {
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_UNSET:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_IS:
- retval = &EG(uninitialized_zval);
- break;
- case BP_VAR_RW:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_W:
- ZVAL_NULL(retval);
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
- }
- }
- }
- if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
- if (Z_CONSTANT_P(retval)) {
- zval_update_constant(retval, 1 TSRMLS_CC);
- }
- } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
- zval_ptr_dtor_nogc(free_op1);
- }
- }
-
- if (IS_VAR != IS_CONST) {
- zend_string_release(name);
- }
-
- ZEND_ASSERT(retval != NULL);
- if (type == BP_VAR_R || type == BP_VAR_IS) {
- if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
- ZVAL_UNREF(retval);
- }
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- } else {
- ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_R_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_VAR_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_W_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_VAR_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_RW_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_VAR_UNUSED(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_FUNC_ARG_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- return zend_fetch_var_address_helper_SPEC_VAR_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else {
- return zend_fetch_var_address_helper_SPEC_VAR_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_UNSET_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_VAR_UNUSED(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_IS_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_VAR_UNUSED(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
static int ZEND_FASTCALL ZEND_FETCH_DIM_W_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
}
}
-static int ZEND_FASTCALL ZEND_UNSET_VAR_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval tmp, *varname;
- HashTable *target_symbol_table;
- zend_free_op free_op1;
-
- SAVE_OPLINE();
- if (IS_VAR == IS_CV &&
- IS_UNUSED == IS_UNUSED &&
- (opline->extended_value & ZEND_QUICK_SET)) {
- zval *var = EX_VAR(opline->op1.var);
-
- if (Z_REFCOUNTED_P(var)) {
- zend_refcounted *garbage = Z_COUNTED_P(var);
-
- if (!--GC_REFCOUNT(garbage)) {
- ZVAL_UNDEF(var);
- _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
- } else {
- GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
- ZVAL_UNDEF(var);
- }
- } else {
- ZVAL_UNDEF(var);
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-
- varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- ZVAL_UNDEF(&tmp);
- if (IS_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
- ZVAL_STR(&tmp, zval_get_string(varname));
- varname = &tmp;
- }
-
- if (IS_UNUSED != IS_UNUSED) {
- zend_class_entry *ce;
-
- if (IS_UNUSED == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(EG(exception) != NULL)) {
- if (IS_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
- }
- zval_ptr_dtor_nogc(free_op1);
- HANDLE_EXCEPTION();
- }
- if (UNEXPECTED(ce == NULL)) {
- zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
- }
- zend_std_unset_static_property(ce, Z_STR_P(varname), ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
- } else {
- target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
- }
-
- if (IS_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
- }
- zval_ptr_dtor_nogc(free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_VAR_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *value;
-
- SAVE_OPLINE();
- if (IS_VAR == IS_CV &&
- IS_UNUSED == IS_UNUSED &&
- (opline->extended_value & ZEND_QUICK_SET)) {
- value = EX_VAR(opline->op1.var);
- if (opline->extended_value & ZEND_ISSET) {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- !i_zend_is_true(value TSRMLS_CC));
- CHECK_EXCEPTION();
- }
- ZEND_VM_NEXT_OPCODE();
- } else {
- zend_free_op free_op1;
- zval tmp, *varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
- ZVAL_UNDEF(&tmp);
- if (IS_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
- ZVAL_STR(&tmp, zval_get_string(varname));
- varname = &tmp;
- }
-
- if (IS_UNUSED != IS_UNUSED) {
- zend_class_entry *ce;
-
- if (IS_UNUSED == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
- }
- value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
- } else {
- HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
- }
-
- if (IS_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
- }
- zval_ptr_dtor_nogc(free_op1);
-
- if (opline->extended_value & ZEND_ISSET) {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- value && Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- !value || !i_zend_is_true(value TSRMLS_CC));
- }
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-}
-
static int ZEND_FASTCALL ZEND_SEPARATE_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_CASE_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *result = EX_VAR(opline->result.var);
-
- SAVE_OPLINE();
- fast_equal_function(result,
- _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
result = 0;
if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
- if (IS_CV == IS_CV || IS_CV == IS_VAR) {
+ if (IS_CV & (IS_CV|IS_VAR)) {
ZVAL_DEREF(offset);
}
if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
return zend_binary_assign_op_helper_SPEC_VAR_CV(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_CLONE_SPEC_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- zval *obj;
- zend_class_entry *ce;
- zend_function *clone;
- zend_object_clone_obj_t clone_call;
-
- SAVE_OPLINE();
- obj = _get_obj_zval_ptr_unused(execute_data);
-
- if (IS_UNUSED == IS_CONST ||
- (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(obj) != IS_OBJECT))) {
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- zend_error_noreturn(E_ERROR, "__clone method called on non-object");
- }
-
- ce = Z_OBJCE_P(obj);
- clone = ce ? ce->clone : NULL;
- clone_call = Z_OBJ_HT_P(obj)->clone_obj;
- if (UNEXPECTED(clone_call == NULL)) {
- if (ce) {
- zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object of class %s", ce->name->val);
- } else {
- zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object");
- }
- }
-
- if (ce && clone) {
- if (clone->op_array.fn_flags & ZEND_ACC_PRIVATE) {
- /* Ensure that if we're calling a private function, we're allowed to do so.
- */
- if (UNEXPECTED(ce != EG(scope))) {
- zend_error_noreturn(E_ERROR, "Call to private %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
- }
- } else if ((clone->common.fn_flags & ZEND_ACC_PROTECTED)) {
- /* Ensure that if we're calling a protected function, we're allowed to do so.
- */
- if (UNEXPECTED(!zend_check_protected(zend_get_function_root_class(clone), EG(scope)))) {
- zend_error_noreturn(E_ERROR, "Call to protected %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
- }
- }
- }
-
- if (EXPECTED(EG(exception) == NULL)) {
- ZVAL_OBJ(EX_VAR(opline->result.var), clone_call(obj TSRMLS_CC));
- if (!RETURN_VALUE_USED(opline) || UNEXPECTED(EG(exception) != NULL)) {
- OBJ_RELEASE(Z_OBJ_P(EX_VAR(opline->result.var)));
- }
- }
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_EXIT_SPEC_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-#if 0 || (IS_UNUSED != IS_UNUSED)
- USE_OPLINE
-
- SAVE_OPLINE();
- if (IS_UNUSED != IS_UNUSED) {
-
- zval *ptr = NULL;
-
- if (Z_TYPE_P(ptr) == IS_LONG) {
- EG(exit_status) = Z_LVAL_P(ptr);
- } else {
- zend_print_variable(ptr TSRMLS_CC);
- }
-
- }
-#endif
- zend_bailout();
- ZEND_VM_NEXT_OPCODE(); /* Never reached */
-}
-
-static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_TMPVAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op_data1;
- zval *object = _get_obj_zval_ptr_unused(execute_data);
- zval *property = opline->op2.zv;
- zval *value;
- zval *zptr;
-
- if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
-
- if (IS_UNUSED != IS_UNUSED) {
- object = make_real_object(object TSRMLS_CC);
- }
-
- value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-
- if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to assign property of non-object");
-
- FREE_OP(free_op_data1);
-
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- } else {
- /* here we are sure we are dealing with an object */
- if (opline->extended_value == ZEND_ASSIGN_OBJ
- && EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
-
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
-
- binary_op(zptr, zptr, value TSRMLS_CC);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), zptr);
- }
- } else {
- zval *z = NULL;
- zval rv;
-
- if (opline->extended_value == ZEND_ASSIGN_OBJ) {
- if (Z_OBJ_HT_P(object)->read_property) {
- z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
- }
- } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
- if (Z_OBJ_HT_P(object)->read_dimension) {
- z = Z_OBJ_HT_P(object)->read_dimension(object, property, BP_VAR_R, &rv TSRMLS_CC);
- }
- }
- if (z) {
- if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
- zval rv;
- zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
-
- if (Z_REFCOUNT_P(z) == 0) {
- zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
- }
- ZVAL_COPY_VALUE(z, value);
- }
-//??? if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
- SEPARATE_ZVAL_IF_NOT_REF(z);
- binary_op(z, z, value TSRMLS_CC);
- if (opline->extended_value == ZEND_ASSIGN_OBJ) {
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
- } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
- Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
- }
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), z);
- }
- zval_ptr_dtor(z);
- } else {
- zend_error(E_WARNING, "Attempt to assign property of non-object");
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- }
- }
-
- FREE_OP(free_op_data1);
- }
-
- /* assign_obj has two opcodes! */
- CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op_data1;
- zval *var_ptr, rv;
- zval *value, *container;
-
- SAVE_OPLINE();
- container = _get_obj_zval_ptr_unused(execute_data);
- if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- if (IS_UNUSED != IS_UNUSED) {
- ZVAL_DEREF(container);
- }
- if (IS_UNUSED == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (IS_UNUSED == IS_VAR && !0) {
- Z_ADDREF_P(container); /* undo the effect of get_obj_zval_ptr_ptr() */
- }
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else {
- zval *dim = opline->op2.zv;
-
- zend_fetch_dimension_address_RW(&rv, container, dim, IS_CONST TSRMLS_CC);
- value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
- var_ptr = Z_INDIRECT(rv);
- }
-
- if (UNEXPECTED(var_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
- }
-
- if (UNEXPECTED(var_ptr == &EG(error_zval))) {
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- } else {
- ZVAL_DEREF(var_ptr);
- SEPARATE_ZVAL_NOREF(var_ptr);
-
- binary_op(var_ptr, var_ptr, value TSRMLS_CC);
-
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
- }
- }
-
- FREE_OP(free_op_data1);
-
- CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- zval *var_ptr;
- zval *value;
-
- SAVE_OPLINE();
- value = opline->op2.zv;
- var_ptr = NULL;
-
- if (IS_UNUSED == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
- }
-
- if (IS_UNUSED == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- } else {
- ZVAL_DEREF(var_ptr);
- SEPARATE_ZVAL_NOREF(var_ptr);
-
- binary_op(var_ptr, var_ptr, value TSRMLS_CC);
-
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
- }
- }
-
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
+ zend_free_op free_op1, free_op2;
zval *object;
zval *property;
zval *retval;
zval *zptr;
SAVE_OPLINE();
- object = _get_obj_zval_ptr_unused(execute_data);
- property = opline->op2.zv;
+ object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
retval = EX_VAR(opline->result.var);
- if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
+ if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
}
- if (IS_UNUSED != IS_UNUSED) {
+ if (IS_VAR != IS_UNUSED) {
object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
}
- if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-
+ zval_ptr_dtor_nogc(free_op2);
if (RETURN_VALUE_USED(opline)) {
ZVAL_NULL(retval);
}
-
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
/* here we are sure we are dealing with an object */
if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
ZVAL_DEREF(zptr);
SEPARATE_ZVAL_NOREF(zptr);
zval rv;
if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+ zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
zval rv;
SEPARATE_ZVAL_IF_NOT_REF(z);
incdec_op(z);
ZVAL_COPY_VALUE(retval, z);
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+ Z_OBJ_HT_P(object)->write_property(object, property, z, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
SELECTIVE_PZVAL_LOCK(retval, opline);
zval_ptr_dtor(z);
} else {
}
}
-
+ zval_ptr_dtor_nogc(free_op2);
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_pre_incdec_property_helper_SPEC_UNUSED_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_pre_incdec_property_helper_SPEC_VAR_TMPVAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_pre_incdec_property_helper_SPEC_UNUSED_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_pre_incdec_property_helper_SPEC_VAR_TMPVAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_TMPVAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
+ zend_free_op free_op1, free_op2;
zval *object;
zval *property;
zval *retval;
zval *zptr;
SAVE_OPLINE();
- object = _get_obj_zval_ptr_unused(execute_data);
- property = opline->op2.zv;
+ object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
retval = EX_VAR(opline->result.var);
- if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
+ if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
}
- if (IS_UNUSED != IS_UNUSED) {
+ if (IS_VAR != IS_UNUSED) {
object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
}
- if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-
+ zval_ptr_dtor_nogc(free_op2);
ZVAL_NULL(retval);
-
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
/* here we are sure we are dealing with an object */
if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
ZVAL_DEREF(zptr);
ZVAL_COPY_VALUE(retval, zptr);
} else {
if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
zval rv;
- zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+ zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
zval z_copy;
if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
ZVAL_DUP(&z_copy, z);
incdec_op(&z_copy);
if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
- Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+ Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
zval_ptr_dtor(&z_copy);
zval_ptr_dtor(z);
} else {
}
}
-
+ zval_ptr_dtor_nogc(free_op2);
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_post_incdec_property_helper_SPEC_UNUSED_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_post_incdec_property_helper_SPEC_VAR_TMPVAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_post_incdec_property_helper_SPEC_UNUSED_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_post_incdec_property_helper_SPEC_VAR_TMPVAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
+ zend_free_op free_op1;
zval *container;
-
+ zend_free_op free_op2;
zval *offset;
SAVE_OPLINE();
- container = _get_obj_zval_ptr_unused(execute_data);
- offset = opline->op2.zv;
+ container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if ((IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+ if ((IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
zend_error(E_NOTICE, "Trying to get property of non-object");
ZVAL_NULL(EX_VAR(opline->result.var));
/* here we are sure we are dealing with an object */
do {
- if (IS_CONST == IS_CONST &&
+ if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
zend_object *zobj = Z_OBJ_P(container);
}
}
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+ retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
if (retval != EX_VAR(opline->result.var)) {
ZVAL_COPY(EX_VAR(opline->result.var), retval);
} while (0);
}
-
+ zval_ptr_dtor_nogc(free_op2);
+ zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_W_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_W_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
+ zend_free_op free_op1, free_op2;
zval *property;
zval *container;
SAVE_OPLINE();
- property = opline->op2.zv;
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- container = _get_obj_zval_ptr_unused(execute_data);
- if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+ container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+ if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
}
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
-
- if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
-
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_RW_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_RW_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
+ zend_free_op free_op1, free_op2;
zval *property;
zval *container;
SAVE_OPLINE();
- property = opline->op2.zv;
- container = _get_obj_zval_ptr_unused(execute_data);
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+ if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
}
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
-
- if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
-
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
+ zend_free_op free_op1;
zval *container;
-
+ zend_free_op free_op2;
zval *offset;
SAVE_OPLINE();
- container = _get_obj_zval_ptr_unused(execute_data);
- offset = opline->op2.zv;
+ container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if ((IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+ if ((IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
ZVAL_NULL(EX_VAR(opline->result.var));
} else {
/* here we are sure we are dealing with an object */
do {
- if (IS_CONST == IS_CONST &&
+ if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
zend_object *zobj = Z_OBJ_P(container);
}
}
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+ retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
if (retval != EX_VAR(opline->result.var)) {
ZVAL_COPY(EX_VAR(opline->result.var), retval);
} while (0);
}
-
+ zval_ptr_dtor_nogc(free_op2);
+ zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *container;
if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
/* Behave like FETCH_OBJ_W */
- zend_free_op free_op1;
+ zend_free_op free_op1, free_op2;
zval *property;
SAVE_OPLINE();
- property = opline->op2.zv;
- container = _get_obj_zval_ptr_unused(execute_data);
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
- if (IS_UNUSED == IS_CONST || IS_UNUSED == IS_TMP_VAR) {
+ if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
}
- if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+ if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
}
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
-
- if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
-
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
} else {
- return ZEND_FETCH_OBJ_R_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return ZEND_FETCH_OBJ_R_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_UNSET_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
+ zend_free_op free_op1, free_op2;
zval *container, *property;
SAVE_OPLINE();
- container = _get_obj_zval_ptr_unused(execute_data);
- property = opline->op2.zv;
+ container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+ if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
}
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
-
- if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
-
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_OBJ_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
+ zend_free_op free_op1, free_op2;
zval *object;
zval *property_name;
SAVE_OPLINE();
- object = _get_obj_zval_ptr_unused(execute_data);
- property_name = opline->op2.zv;
+ object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+ property_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
+ if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
- zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_UNUSED, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
-
-
+ zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_VAR, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
/* assign_obj has two opcodes! */
CHECK_EXCEPTION();
ZEND_VM_INC_OPCODE();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ADD_CHAR_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *str = EX_VAR(opline->result.var);
-
- SAVE_OPLINE();
-
- if (IS_UNUSED == IS_UNUSED) {
- /* Initialize for erealloc in add_char_to_string */
- ZVAL_EMPTY_STRING(str);
- }
-
- add_char_to_string(str, str, opline->op2.zv);
-
- /* FREE_OP is missing intentionally here - we're always working on the same temporary variable */
- /*CHECK_EXCEPTION();*/
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_ADD_STRING_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *str = EX_VAR(opline->result.var);
-
- SAVE_OPLINE();
-
- if (IS_UNUSED == IS_UNUSED) {
- /* Initialize for erealloc in add_string_to_string */
- ZVAL_EMPTY_STRING(str);
- }
-
- add_string_to_string(str, str, opline->op2.zv);
-
- /* FREE_OP is missing intentionally here - we're always working on the same temporary variable */
- /*CHECK_EXCEPTION();*/
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *function_name;
-
+ zend_free_op free_op1, free_op2;
zval *object;
zend_function *fbc;
zend_class_entry *called_scope;
SAVE_OPLINE();
- function_name = opline->op2.zv;
+ function_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_CONST != IS_CONST &&
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST &&
UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
if (UNEXPECTED(EG(exception) != NULL)) {
HANDLE_EXCEPTION();
zend_error_noreturn(E_ERROR, "Method name must be a string");
}
- object = _get_obj_zval_ptr_unused(execute_data);
+ object = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
- if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
uint32_t nesting = 1;
if (UNEXPECTED(EG(exception) != NULL)) {
-
+ zval_ptr_dtor_nogc(free_op2);
HANDLE_EXCEPTION();
}
zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s", Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
-
+ zval_ptr_dtor_nogc(free_op2);
+ zval_ptr_dtor_nogc(free_op1);
if (EG(exception) != NULL) {
HANDLE_EXCEPTION();
obj = Z_OBJ_P(object);
called_scope = obj->ce;
- if (IS_CONST != IS_CONST ||
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST ||
EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
zend_object *orig_obj = obj;
}
/* First, locate the function. */
- fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_CONST == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
+ fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
if (UNEXPECTED(fbc == NULL)) {
zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
}
- if (IS_CONST == IS_CONST &&
+ if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
EXPECTED(obj == orig_obj)) {
EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_CONSTANT_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *function_name;
+ zend_class_entry *ce;
+ zend_object *object;
+ zend_function *fbc;
SAVE_OPLINE();
- if (IS_UNUSED == IS_UNUSED) {
- zend_constant *c;
- zval *retval;
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- c = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else if ((c = zend_quick_get_constant(opline->op2.zv + 1, opline->extended_value TSRMLS_CC)) == NULL) {
- if ((opline->extended_value & IS_CONSTANT_UNQUALIFIED) != 0) {
- char *actual = (char *)zend_memrchr(Z_STRVAL_P(opline->op2.zv), '\\', Z_STRLEN_P(opline->op2.zv));
- if (!actual) {
- ZVAL_STR(EX_VAR(opline->result.var), zend_string_copy(Z_STR_P(opline->op2.zv)));
- } else {
- actual++;
- ZVAL_STRINGL(EX_VAR(opline->result.var),
- actual, Z_STRLEN_P(opline->op2.zv) - (actual - Z_STRVAL_P(opline->op2.zv)));
- }
- /* non-qualified constant - allow text substitution */
- zend_error(E_NOTICE, "Use of undefined constant %s - assumed '%s'",
- Z_STRVAL_P(EX_VAR(opline->result.var)), Z_STRVAL_P(EX_VAR(opline->result.var)));
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- } else {
- zend_error_noreturn(E_ERROR, "Undefined constant '%s'", Z_STRVAL_P(opline->op2.zv));
- }
+ if (IS_VAR == IS_CONST) {
+ /* no function found. try a static method in class */
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv));
} else {
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), c);
- }
- retval = EX_VAR(opline->result.var);
- ZVAL_COPY_VALUE(retval, &c->value);
- if (Z_OPT_COPYABLE_P(retval) || Z_OPT_REFCOUNTED_P(retval)) {
- if (Z_OPT_COPYABLE_P(retval)) {
- zval_copy_ctor_func(retval);
- } else {
- Z_ADDREF_P(retval);
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op1.zv), opline->op1.zv + 1, ZEND_FETCH_CLASS_DEFAULT TSRMLS_CC);
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ if (UNEXPECTED(ce == NULL)) {
+ zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
}
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op1.zv), ce);
}
} else {
- /* class constant */
- zend_class_entry *ce;
- zval *value;
+ ce = Z_CE_P(EX_VAR(opline->op1.var));
+ }
- if (IS_UNUSED == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- value = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- ZVAL_DEREF(value);
- ZVAL_DUP(EX_VAR(opline->result.var), value);
- goto constant_fetch_end;
- } else if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op1.zv), opline->op1.zv + 1, 0 TSRMLS_CC);
+ if (IS_VAR == IS_CONST &&
+ (IS_TMP_VAR|IS_VAR) == IS_CONST &&
+ CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ fbc = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ } else if (IS_VAR != IS_CONST &&
+ (IS_TMP_VAR|IS_VAR) == IS_CONST &&
+ (fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce))) {
+ /* do nothing */
+ } else if ((IS_TMP_VAR|IS_VAR) != IS_UNUSED) {
+ zend_free_op free_op2;
+
+ function_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+ if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
if (UNEXPECTED(EG(exception) != NULL)) {
HANDLE_EXCEPTION();
}
- if (UNEXPECTED(ce == NULL)) {
- zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op1.zv), ce);
- }
+ zend_error_noreturn(E_ERROR, "Function name must be a string");
+ }
+ }
+
+ if (ce->get_static_method) {
+ fbc = ce->get_static_method(ce, Z_STR_P(function_name) TSRMLS_CC);
} else {
- ce = Z_CE_P(EX_VAR(opline->op1.var));
- if ((value = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce)) != NULL) {
- ZVAL_DEREF(value);
- ZVAL_DUP(EX_VAR(opline->result.var), value);
- goto constant_fetch_end;
+ fbc = zend_std_get_static_method(ce, Z_STR_P(function_name), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
+ }
+ if (UNEXPECTED(fbc == NULL)) {
+ zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name->val, Z_STRVAL_P(function_name));
+ }
+ if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
+ EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
+ EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0)) {
+ if (IS_VAR == IS_CONST) {
+ CACHE_PTR(Z_CACHE_SLOT_P(function_name), fbc);
+ } else {
+ CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), ce, fbc);
}
}
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+ zval_ptr_dtor_nogc(free_op2);
+ }
+ } else {
+ if (UNEXPECTED(ce->constructor == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot call constructor");
+ }
+ if (Z_OBJ(EX(This)) && Z_OBJ(EX(This))->ce != ce->constructor->common.scope && (ce->constructor->common.fn_flags & ZEND_ACC_PRIVATE)) {
+ zend_error_noreturn(E_ERROR, "Cannot call private %s::__construct()", ce->name->val);
+ }
+ fbc = ce->constructor;
+ }
- if (EXPECTED((value = zend_hash_find(&ce->constants_table, Z_STR_P(opline->op2.zv))) != NULL)) {
- ZVAL_DEREF(value);
- if (Z_CONSTANT_P(value)) {
- EG(scope) = ce;
- zval_update_constant(value, 1 TSRMLS_CC);
- EG(scope) = EX(func)->op_array.scope;
- }
- if (IS_UNUSED == IS_CONST) {
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), value);
+ object = NULL;
+ if (!(fbc->common.fn_flags & ZEND_ACC_STATIC)) {
+ if (Z_OBJ(EX(This))) {
+ object = Z_OBJ(EX(This));
+ GC_REFCOUNT(object)++;
+ }
+ if (!object ||
+ !instanceof_function(object->ce, ce TSRMLS_CC)) {
+ /* We are calling method of the other (incompatible) class,
+ but passing $this. This is done for compatibility with php-4. */
+ if (fbc->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
+ zend_error(
+ object ? E_DEPRECATED : E_STRICT,
+ "Non-static method %s::%s() should not be called statically%s",
+ fbc->common.scope->name->val, fbc->common.function_name->val,
+ object ? ", assuming $this from incompatible context" : "");
} else {
- CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce, value);
+ /* An internal function assumes $this is present and won't check that. So PHP would crash by allowing the call. */
+ zend_error_noreturn(
+ E_ERROR,
+ "Non-static method %s::%s() cannot be called statically%s",
+ fbc->common.scope->name->val, fbc->common.function_name->val,
+ object ? ", assuming $this from incompatible context" : "");
}
- ZVAL_DUP(EX_VAR(opline->result.var), value);
- } else if (Z_STRLEN_P(opline->op2.zv) == sizeof("class")-1 && memcmp(Z_STRVAL_P(opline->op2.zv), "class", sizeof("class") - 1) == 0) {
- /* "class" is assigned as a case-sensitive keyword from zend_do_resolve_class_name */
- ZVAL_STR_COPY(EX_VAR(opline->result.var), ce->name);
- } else {
- zend_error_noreturn(E_ERROR, "Undefined class constant '%s'", Z_STRVAL_P(opline->op2.zv));
}
}
-constant_fetch_end:
+
+ if (IS_VAR != IS_CONST) {
+ /* previous opcode is ZEND_FETCH_CLASS */
+ if ((opline-1)->extended_value == ZEND_FETCH_CLASS_PARENT || (opline-1)->extended_value == ZEND_FETCH_CLASS_SELF) {
+ ce = EX(called_scope);
+ }
+ }
+
+ EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
+ fbc, opline->extended_value, ce, object, EX(call) TSRMLS_CC);
+
+ if ((IS_TMP_VAR|IS_VAR) == IS_UNUSED) {
+ EX(call)->return_value = NULL;
+ }
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+ zval *expr_ptr, new_expr;
+
+ SAVE_OPLINE();
+ if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) &&
+ (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
+ expr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+ if (IS_VAR == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
+ }
+ ZVAL_MAKE_REF(expr_ptr);
+ Z_ADDREF_P(expr_ptr);
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+ } else {
+ expr_ptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+ if (IS_VAR == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&new_expr, expr_ptr);
+ expr_ptr = &new_expr;
+ } else if (IS_VAR == IS_CONST) {
+ if (!Z_IMMUTABLE_P(expr_ptr)) {
+ ZVAL_DUP(&new_expr, expr_ptr);
+ expr_ptr = &new_expr;
+ }
+ } else if ((IS_VAR == IS_CV || IS_VAR == IS_VAR) && Z_ISREF_P(expr_ptr)) {
+ expr_ptr = Z_REFVAL_P(expr_ptr);
+ if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
+ zval_ptr_dtor_nogc(free_op1);
+ } else if (IS_VAR == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
+ Z_ADDREF_P(expr_ptr);
+ }
+ }
+
+ if ((IS_TMP_VAR|IS_VAR) != IS_UNUSED) {
+ zend_free_op free_op2;
+ zval *offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ zend_string *str;
+ zend_ulong hval;
+
+add_again:
+ switch (Z_TYPE_P(offset)) {
+ case IS_DOUBLE:
+ hval = zend_dval_to_lval(Z_DVAL_P(offset));
+ goto num_index;
+ case IS_LONG:
+ hval = Z_LVAL_P(offset);
+num_index:
+ zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
+ break;
+ case IS_STRING:
+ str = Z_STR_P(offset);
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+ if (ZEND_HANDLE_NUMERIC(str, hval)) {
+ goto num_index;
+ }
+ }
+str_index:
+ zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
+ break;
+ case IS_NULL:
+ str = STR_EMPTY_ALLOC();
+ goto str_index;
+ case IS_FALSE:
+ hval = 0;
+ goto num_index;
+ case IS_TRUE:
+ hval = 1;
+ goto num_index;
+ case IS_REFERENCE:
+ offset = Z_REFVAL_P(offset);
+ goto add_again;
+ break;
+ default:
+ zend_error(E_WARNING, "Illegal offset type");
+ zval_ptr_dtor(expr_ptr);
+ /* do nothing */
+ break;
+ }
+ zval_ptr_dtor_nogc(free_op2);
+ } else {
+ zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
+ }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
zval *array;
uint32_t size;
USE_OPLINE
array = EX_VAR(opline->result.var);
- if (IS_UNUSED != IS_UNUSED) {
+ if (IS_VAR != IS_UNUSED) {
size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
} else {
size = 0;
ZVAL_NEW_ARR(array);
zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
- if (IS_UNUSED != IS_UNUSED) {
+ if (IS_VAR != IS_UNUSED) {
/* Explicitly initialize array as not-packed if flag is set */
if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
zend_hash_real_init(Z_ARRVAL_P(array), 0);
}
}
- if (IS_UNUSED == IS_UNUSED) {
+ if (IS_VAR == IS_UNUSED) {
ZEND_VM_NEXT_OPCODE();
-#if 0 || IS_UNUSED != IS_UNUSED
+#if 0 || IS_VAR != IS_UNUSED
} else {
- return ZEND_ADD_ARRAY_ELEMENT_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
#endif
}
}
-static int ZEND_FASTCALL ZEND_UNSET_DIM_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_UNSET_DIM_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
+ zend_free_op free_op1, free_op2;
zval *container;
zval *offset;
zend_ulong hval;
SAVE_OPLINE();
- container = _get_obj_zval_ptr_unused(execute_data);
- if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+ container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+ if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
}
- if (IS_UNUSED != IS_UNUSED) {
+ if (IS_VAR != IS_UNUSED) {
ZVAL_DEREF(container);
}
SEPARATE_ZVAL_NOREF(container);
- offset = opline->op2.zv;
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_UNUSED != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
+ if (IS_VAR != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
HashTable *ht = Z_ARRVAL_P(container);
offset_again:
switch (Z_TYPE_P(offset)) {
zend_hash_index_del(ht, hval);
break;
case IS_STRING:
- if (IS_CONST != IS_CONST) {
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
goto num_index_dim;
}
zend_error(E_WARNING, "Illegal offset type in unset");
break;
}
-
- } else if (IS_UNUSED == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ zval_ptr_dtor_nogc(free_op2);
+ } else if (IS_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use object as array");
}
-//??? if (IS_CONST == IS_CONST) {
+//??? if ((IS_TMP_VAR|IS_VAR) == IS_CONST) {
//??? zval_copy_ctor(offset);
//??? }
Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
-
+ zval_ptr_dtor_nogc(free_op2);
} else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
ZEND_VM_CONTINUE(); /* bailed out before */
} else {
-
+ zval_ptr_dtor_nogc(free_op2);
}
-
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_UNSET_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_UNSET_OBJ_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
+ zend_free_op free_op1, free_op2;
zval *container;
zval *offset;
SAVE_OPLINE();
- container = _get_obj_zval_ptr_unused(execute_data);
- if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+ container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+ if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
}
- offset = opline->op2.zv;
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_UNUSED != IS_UNUSED) {
+ if (IS_VAR != IS_UNUSED) {
ZVAL_DEREF(container);
}
- if (IS_UNUSED == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
+ if (IS_VAR == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
if (Z_OBJ_HT_P(container)->unset_property) {
- Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+ Z_OBJ_HT_P(container)->unset_property(container, offset, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
} else {
zend_error(E_NOTICE, "Trying to unset property of non-object");
}
}
-
-
+ zval_ptr_dtor_nogc(free_op2);
+ if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
+ zend_free_op free_op1, free_op2;
zval *container;
int result;
zend_ulong hval;
zval *offset;
SAVE_OPLINE();
- container = _get_obj_zval_ptr_unused(execute_data);
- offset = opline->op2.zv;
+ container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_UNUSED != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
+ if (IS_VAR != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
HashTable *ht = Z_ARRVAL_P(container);
zval *value;
zend_string *str;
isset_again:
if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
str = Z_STR_P(offset);
- if (IS_CONST != IS_CONST) {
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
if (ZEND_HANDLE_NUMERIC(str, hval)) {
goto num_index_prop;
}
} else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
}
- } else if (IS_UNUSED == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ } else if (IS_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
} else {
result = 0;
if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
- if (IS_CONST == IS_CV || IS_CONST == IS_VAR) {
+ if ((IS_TMP_VAR|IS_VAR) & (IS_CV|IS_VAR)) {
ZVAL_DEREF(offset);
}
if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
result = ((opline->extended_value & ZEND_ISSET) == 0);
}
+ zval_ptr_dtor_nogc(free_op2);
ZVAL_BOOL(EX_VAR(opline->result.var), result);
-
+ zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
+ zend_free_op free_op1, free_op2;
zval *container;
int result;
zval *offset;
SAVE_OPLINE();
- container = _get_obj_zval_ptr_unused(execute_data);
- offset = opline->op2.zv;
+ container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_UNUSED == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ if (IS_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
- result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+ result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
} else {
zend_error(E_NOTICE, "Trying to check property of non-object");
result = 0;
result = ((opline->extended_value & ZEND_ISSET) == 0);
}
+ zval_ptr_dtor_nogc(free_op2);
ZVAL_BOOL(EX_VAR(opline->result.var), result);
-
+ zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_YIELD_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_CLONE_SPEC_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- /* The generator object is stored in EX(return_value) */
- zend_generator *generator = (zend_generator *) EX(return_value);
-
- if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
- zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
- }
-
- /* Destroy the previously yielded value */
- zval_ptr_dtor(&generator->value);
-
- /* Destroy the previously yielded key */
- zval_ptr_dtor(&generator->key);
-
- /* Set the new yielded value */
- if (IS_UNUSED != IS_UNUSED) {
-
-
- if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
- /* Constants and temporary variables aren't yieldable by reference,
- * but we still allow them with a notice. */
- if (IS_UNUSED == IS_CONST || IS_UNUSED == IS_TMP_VAR) {
- zval *value;
-
- zend_error(E_NOTICE, "Only variable references should be yielded by reference");
-
- value = NULL;
- ZVAL_COPY_VALUE(&generator->value, value);
- if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
-
- /* Temporary variables don't need ctor copying */
- if (IS_UNUSED != IS_TMP_VAR) {
- zval_opt_copy_ctor(&generator->value);
- }
- } else {
- zval *value_ptr = NULL;
+ zval *obj;
+ zend_class_entry *ce;
+ zend_function *clone;
+ zend_object_clone_obj_t clone_call;
- if (IS_UNUSED == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
- }
+ SAVE_OPLINE();
+ obj = _get_obj_zval_ptr_unused(execute_data);
- /* If a function call result is yielded and the function did
- * not return by reference we throw a notice. */
- if (IS_UNUSED == IS_VAR &&
- (value_ptr == &EG(uninitialized_zval) ||
- (opline->extended_value == ZEND_RETURNS_FUNCTION &&
- !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
- zend_error(E_NOTICE, "Only variable references should be yielded by reference");
- } else {
- ZVAL_MAKE_REF(value_ptr);
- }
- ZVAL_COPY(&generator->value, value_ptr);
+ if (IS_UNUSED == IS_CONST ||
+ (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(obj) != IS_OBJECT))) {
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ zend_error_noreturn(E_ERROR, "__clone method called on non-object");
+ }
- }
+ ce = Z_OBJCE_P(obj);
+ clone = ce ? ce->clone : NULL;
+ clone_call = Z_OBJ_HT_P(obj)->clone_obj;
+ if (UNEXPECTED(clone_call == NULL)) {
+ if (ce) {
+ zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object of class %s", ce->name->val);
} else {
- zval *value = NULL;
-
- /* Consts, temporary variables and references need copying */
- if (IS_UNUSED == IS_CONST) {
- ZVAL_DUP(&generator->value, value);
- } else if (IS_UNUSED == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&generator->value, value);
- } else if ((IS_UNUSED == IS_CV || IS_UNUSED == IS_VAR) && Z_ISREF_P(value)) {
- ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
-
- } else {
- ZVAL_COPY_VALUE(&generator->value, value);
- if (IS_UNUSED == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
- }
- }
+ zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object");
}
- } else {
- /* If no value was specified yield null */
- ZVAL_NULL(&generator->value);
}
- /* Set the new yielded key */
- if (IS_CONST != IS_UNUSED) {
-
- zval *key = opline->op2.zv;
-
- /* Consts, temporary variables and references need copying */
- if (IS_CONST == IS_CONST) {
- ZVAL_DUP(&generator->key, key);
- } else if (IS_CONST == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&generator->key, key);
- } else if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) && Z_ISREF_P(key)) {
- ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
-
- } else {
- ZVAL_COPY_VALUE(&generator->key, key);
- if (IS_CONST == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
+ if (ce && clone) {
+ if (clone->op_array.fn_flags & ZEND_ACC_PRIVATE) {
+ /* Ensure that if we're calling a private function, we're allowed to do so.
+ */
+ if (UNEXPECTED(ce != EG(scope))) {
+ zend_error_noreturn(E_ERROR, "Call to private %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
+ }
+ } else if ((clone->common.fn_flags & ZEND_ACC_PROTECTED)) {
+ /* Ensure that if we're calling a protected function, we're allowed to do so.
+ */
+ if (UNEXPECTED(!zend_check_protected(zend_get_function_root_class(clone), EG(scope)))) {
+ zend_error_noreturn(E_ERROR, "Call to protected %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
}
}
+ }
- if (Z_TYPE(generator->key) == IS_LONG
- && Z_LVAL(generator->key) > generator->largest_used_integer_key
- ) {
- generator->largest_used_integer_key = Z_LVAL(generator->key);
+ if (EXPECTED(EG(exception) == NULL)) {
+ ZVAL_OBJ(EX_VAR(opline->result.var), clone_call(obj TSRMLS_CC));
+ if (!RETURN_VALUE_USED(opline) || UNEXPECTED(EG(exception) != NULL)) {
+ OBJ_RELEASE(Z_OBJ_P(EX_VAR(opline->result.var)));
}
- } else {
- /* If no key was specified we use auto-increment keys */
- generator->largest_used_integer_key++;
- ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
}
- if (RETURN_VALUE_USED(opline)) {
- /* If the return value of yield is used set the send
- * target and initialize it to NULL */
- generator->send_target = EX_VAR(opline->result.var);
- ZVAL_NULL(generator->send_target);
- } else {
- generator->send_target = NULL;
- }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- /* We increment to the next op, so we are at the correct position when the
- * generator is resumed. */
- ZEND_VM_INC_OPCODE();
+static int ZEND_FASTCALL ZEND_EXIT_SPEC_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || (IS_UNUSED != IS_UNUSED)
+ USE_OPLINE
- /* The GOTO VM uses a local opline variable. We need to set the opline
- * variable in execute_data so we don't resume at an old position. */
SAVE_OPLINE();
+ if (IS_UNUSED != IS_UNUSED) {
- ZEND_VM_RETURN();
-}
+ zval *ptr = NULL;
-static int ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ if (Z_TYPE_P(ptr) == IS_LONG) {
+ EG(exit_status) = Z_LVAL_P(ptr);
+ } else {
+ zend_print_variable(ptr TSRMLS_CC);
+ }
+
+ }
+#endif
+ zend_bailout();
+ ZEND_VM_NEXT_OPCODE(); /* Never reached */
}
-static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2, free_op_data1;
+ zend_free_op free_op_data1;
zval *object = _get_obj_zval_ptr_unused(execute_data);
- zval *property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ zval *property = opline->op2.zv;
zval *value;
zval *zptr;
if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
zend_error(E_WARNING, "Attempt to assign property of non-object");
- zval_ptr_dtor_nogc(free_op2);
+
FREE_OP(free_op_data1);
if (RETURN_VALUE_USED(opline)) {
/* here we are sure we are dealing with an object */
if (opline->extended_value == ZEND_ASSIGN_OBJ
&& EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
ZVAL_DEREF(zptr);
SEPARATE_ZVAL_NOREF(zptr);
if (opline->extended_value == ZEND_ASSIGN_OBJ) {
if (Z_OBJ_HT_P(object)->read_property) {
- z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+ z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
}
} else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
if (Z_OBJ_HT_P(object)->read_dimension) {
SEPARATE_ZVAL_IF_NOT_REF(z);
binary_op(z, z, value TSRMLS_CC);
if (opline->extended_value == ZEND_ASSIGN_OBJ) {
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+ Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
} else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
}
}
}
- zval_ptr_dtor_nogc(free_op2);
FREE_OP(free_op_data1);
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2, free_op_data1;
+ zend_free_op free_op_data1;
zval *var_ptr, rv;
zval *value, *container;
if (IS_UNUSED == IS_VAR && !0) {
Z_ADDREF_P(container); /* undo the effect of get_obj_zval_ptr_ptr() */
}
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else {
- zval *dim = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ zval *dim = opline->op2.zv;
- zend_fetch_dimension_address_RW(&rv, container, dim, IS_TMP_VAR TSRMLS_CC);
+ zend_fetch_dimension_address_RW(&rv, container, dim, IS_CONST TSRMLS_CC);
value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
var_ptr = Z_INDIRECT(rv);
}
}
- zval_ptr_dtor_nogc(free_op2);
FREE_OP(free_op_data1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
+
zval *var_ptr;
zval *value;
SAVE_OPLINE();
- value = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ value = opline->op2.zv;
var_ptr = NULL;
if (IS_UNUSED == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
}
}
- zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_TMP(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
+
zval *object;
zval *property;
zval *retval;
SAVE_OPLINE();
object = _get_obj_zval_ptr_unused(execute_data);
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ property = opline->op2.zv;
retval = EX_VAR(opline->result.var);
if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- zval_ptr_dtor_nogc(free_op2);
+
if (RETURN_VALUE_USED(opline)) {
ZVAL_NULL(retval);
}
/* here we are sure we are dealing with an object */
if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
ZVAL_DEREF(zptr);
SEPARATE_ZVAL_NOREF(zptr);
zval rv;
if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+ zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
zval rv;
SEPARATE_ZVAL_IF_NOT_REF(z);
incdec_op(z);
ZVAL_COPY_VALUE(retval, z);
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+ Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
SELECTIVE_PZVAL_LOCK(retval, opline);
zval_ptr_dtor(z);
} else {
}
}
- zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_pre_incdec_property_helper_SPEC_UNUSED_TMP(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_pre_incdec_property_helper_SPEC_UNUSED_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_pre_incdec_property_helper_SPEC_UNUSED_TMP(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_pre_incdec_property_helper_SPEC_UNUSED_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_TMP(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
+
zval *object;
zval *property;
zval *retval;
SAVE_OPLINE();
object = _get_obj_zval_ptr_unused(execute_data);
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ property = opline->op2.zv;
retval = EX_VAR(opline->result.var);
if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- zval_ptr_dtor_nogc(free_op2);
+
ZVAL_NULL(retval);
CHECK_EXCEPTION();
/* here we are sure we are dealing with an object */
if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
ZVAL_DEREF(zptr);
ZVAL_COPY_VALUE(retval, zptr);
} else {
if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
zval rv;
- zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+ zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
zval z_copy;
if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
ZVAL_DUP(&z_copy, z);
incdec_op(&z_copy);
if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
- Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+ Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
zval_ptr_dtor(&z_copy);
zval_ptr_dtor(z);
} else {
}
}
- zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_post_incdec_property_helper_SPEC_UNUSED_TMP(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_post_incdec_property_helper_SPEC_UNUSED_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_post_incdec_property_helper_SPEC_UNUSED_TMP(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_post_incdec_property_helper_SPEC_UNUSED_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *container;
- zend_free_op free_op2;
+
zval *offset;
SAVE_OPLINE();
container = _get_obj_zval_ptr_unused(execute_data);
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ offset = opline->op2.zv;
if ((IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
/* here we are sure we are dealing with an object */
do {
- if (IS_TMP_VAR == IS_CONST &&
+ if (IS_CONST == IS_CONST &&
EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
zend_object *zobj = Z_OBJ_P(container);
}
}
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+ retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
if (retval != EX_VAR(opline->result.var)) {
ZVAL_COPY(EX_VAR(opline->result.var), retval);
} while (0);
}
- zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_W_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_W_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *property;
zval *container;
SAVE_OPLINE();
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ property = opline->op2.zv;
container = _get_obj_zval_ptr_unused(execute_data);
if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
}
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+
if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_RW_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_RW_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *property;
zval *container;
SAVE_OPLINE();
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ property = opline->op2.zv;
container = _get_obj_zval_ptr_unused(execute_data);
if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
}
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
+
if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *container;
- zend_free_op free_op2;
+
zval *offset;
SAVE_OPLINE();
container = _get_obj_zval_ptr_unused(execute_data);
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ offset = opline->op2.zv;
if ((IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
/* here we are sure we are dealing with an object */
do {
- if (IS_TMP_VAR == IS_CONST &&
+ if (IS_CONST == IS_CONST &&
EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
zend_object *zobj = Z_OBJ_P(container);
}
}
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+ retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
if (retval != EX_VAR(opline->result.var)) {
ZVAL_COPY(EX_VAR(opline->result.var), retval);
} while (0);
}
- zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *container;
if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
/* Behave like FETCH_OBJ_W */
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *property;
SAVE_OPLINE();
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ property = opline->op2.zv;
container = _get_obj_zval_ptr_unused(execute_data);
if (IS_UNUSED == IS_CONST || IS_UNUSED == IS_TMP_VAR) {
if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
}
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+
if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
} else {
- return ZEND_FETCH_OBJ_R_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return ZEND_FETCH_OBJ_R_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op1;
zval *container, *property;
SAVE_OPLINE();
container = _get_obj_zval_ptr_unused(execute_data);
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ property = opline->op2.zv;
if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
}
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
+
if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
+
zval *object;
zval *property_name;
SAVE_OPLINE();
object = _get_obj_zval_ptr_unused(execute_data);
- property_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ property_name = opline->op2.zv;
if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
- zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_UNUSED, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_UNUSED, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+
/* assign_obj has two opcodes! */
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ADD_VAR_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ADD_CHAR_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
zval *str = EX_VAR(opline->result.var);
- zval *var;
- zval var_copy;
- int use_copy = 0;
SAVE_OPLINE();
- var = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
if (IS_UNUSED == IS_UNUSED) {
- /* Initialize for erealloc in add_string_to_string */
+ /* Initialize for erealloc in add_char_to_string */
ZVAL_EMPTY_STRING(str);
}
- if (Z_TYPE_P(var) != IS_STRING) {
- if (IS_TMP_VAR != IS_TMP_VAR) {
- ZVAL_DEREF(var);
- }
- if (Z_TYPE_P(var) != IS_STRING) {
- use_copy = zend_make_printable_zval(var, &var_copy TSRMLS_CC);
+ add_char_to_string(str, str, opline->op2.zv);
- if (use_copy) {
- var = &var_copy;
- }
- }
- }
- add_string_to_string(str, str, var);
+ /* FREE_OP is missing intentionally here - we're always working on the same temporary variable */
+ /*CHECK_EXCEPTION();*/
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_ADD_STRING_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zval *str = EX_VAR(opline->result.var);
- if (use_copy) {
- zend_string_release(Z_STR_P(var));
+ SAVE_OPLINE();
+
+ if (IS_UNUSED == IS_UNUSED) {
+ /* Initialize for erealloc in add_string_to_string */
+ ZVAL_EMPTY_STRING(str);
}
- /* original comment, possibly problematic:
- * FREE_OP is missing intentionally here - we're always working on the same temporary variable
- * (Zeev): I don't think it's problematic, we only use variables
- * which aren't affected by FREE_OP(Ts, )'s anyway, unless they're
- * string offsets or overloaded objects
- */
- zval_ptr_dtor_nogc(free_op2);
- CHECK_EXCEPTION();
+ add_string_to_string(str, str, opline->op2.zv);
+
+ /* FREE_OP is missing intentionally here - we're always working on the same temporary variable */
+ /*CHECK_EXCEPTION();*/
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *function_name;
- zend_free_op free_op2;
+
zval *object;
zend_function *fbc;
zend_class_entry *called_scope;
SAVE_OPLINE();
- function_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ function_name = opline->op2.zv;
- if (IS_TMP_VAR != IS_CONST &&
+ if (IS_CONST != IS_CONST &&
UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
if (UNEXPECTED(EG(exception) != NULL)) {
HANDLE_EXCEPTION();
uint32_t nesting = 1;
if (UNEXPECTED(EG(exception) != NULL)) {
- zval_ptr_dtor_nogc(free_op2);
+
HANDLE_EXCEPTION();
}
zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s", Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
- zval_ptr_dtor_nogc(free_op2);
+
if (EG(exception) != NULL) {
HANDLE_EXCEPTION();
obj = Z_OBJ_P(object);
called_scope = obj->ce;
- if (IS_TMP_VAR != IS_CONST ||
+ if (IS_CONST != IS_CONST ||
EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
zend_object *orig_obj = obj;
}
/* First, locate the function. */
- fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_TMP_VAR == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
+ fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_CONST == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
if (UNEXPECTED(fbc == NULL)) {
zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
}
- if (IS_TMP_VAR == IS_CONST &&
+ if (IS_CONST == IS_CONST &&
EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
EXPECTED(obj == orig_obj)) {
EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_CONSTANT_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ SAVE_OPLINE();
+ if (IS_UNUSED == IS_UNUSED) {
+ zend_constant *c;
+ zval *retval;
+
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ c = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ } else if ((c = zend_quick_get_constant(opline->op2.zv + 1, opline->extended_value TSRMLS_CC)) == NULL) {
+ if ((opline->extended_value & IS_CONSTANT_UNQUALIFIED) != 0) {
+ char *actual = (char *)zend_memrchr(Z_STRVAL_P(opline->op2.zv), '\\', Z_STRLEN_P(opline->op2.zv));
+ if (!actual) {
+ ZVAL_STR(EX_VAR(opline->result.var), zend_string_copy(Z_STR_P(opline->op2.zv)));
+ } else {
+ actual++;
+ ZVAL_STRINGL(EX_VAR(opline->result.var),
+ actual, Z_STRLEN_P(opline->op2.zv) - (actual - Z_STRVAL_P(opline->op2.zv)));
+ }
+ /* non-qualified constant - allow text substitution */
+ zend_error(E_NOTICE, "Use of undefined constant %s - assumed '%s'",
+ Z_STRVAL_P(EX_VAR(opline->result.var)), Z_STRVAL_P(EX_VAR(opline->result.var)));
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ } else {
+ zend_error_noreturn(E_ERROR, "Undefined constant '%s'", Z_STRVAL_P(opline->op2.zv));
+ }
+ } else {
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), c);
+ }
+ retval = EX_VAR(opline->result.var);
+ ZVAL_COPY_VALUE(retval, &c->value);
+ if (Z_OPT_COPYABLE_P(retval) || Z_OPT_REFCOUNTED_P(retval)) {
+ if (Z_OPT_COPYABLE_P(retval)) {
+ zval_copy_ctor_func(retval);
+ } else {
+ Z_ADDREF_P(retval);
+ }
+ }
+ } else {
+ /* class constant */
+ zend_class_entry *ce;
+ zval *value;
+
+ if (IS_UNUSED == IS_CONST) {
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ value = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ ZVAL_DEREF(value);
+ ZVAL_DUP(EX_VAR(opline->result.var), value);
+ goto constant_fetch_end;
+ } else if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv));
+ } else {
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op1.zv), opline->op1.zv + 1, 0 TSRMLS_CC);
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ if (UNEXPECTED(ce == NULL)) {
+ zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
+ }
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op1.zv), ce);
+ }
+ } else {
+ ce = Z_CE_P(EX_VAR(opline->op1.var));
+ if ((value = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce)) != NULL) {
+ ZVAL_DEREF(value);
+ ZVAL_DUP(EX_VAR(opline->result.var), value);
+ goto constant_fetch_end;
+ }
+ }
+
+ if (EXPECTED((value = zend_hash_find(&ce->constants_table, Z_STR_P(opline->op2.zv))) != NULL)) {
+ ZVAL_DEREF(value);
+ if (Z_CONSTANT_P(value)) {
+ EG(scope) = ce;
+ zval_update_constant(value, 1 TSRMLS_CC);
+ EG(scope) = EX(func)->op_array.scope;
+ }
+ if (IS_UNUSED == IS_CONST) {
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), value);
+ } else {
+ CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce, value);
+ }
+ ZVAL_DUP(EX_VAR(opline->result.var), value);
+ } else if (Z_STRLEN_P(opline->op2.zv) == sizeof("class")-1 && memcmp(Z_STRVAL_P(opline->op2.zv), "class", sizeof("class") - 1) == 0) {
+ /* "class" is assigned as a case-sensitive keyword from zend_do_resolve_class_name */
+ ZVAL_STR_COPY(EX_VAR(opline->result.var), ce->name);
+ } else {
+ zend_error_noreturn(E_ERROR, "Undefined class constant '%s'", Z_STRVAL_P(opline->op2.zv));
+ }
+ }
+constant_fetch_end:
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
zval *array;
uint32_t size;
ZEND_VM_NEXT_OPCODE();
#if 0 || IS_UNUSED != IS_UNUSED
} else {
- return ZEND_ADD_ARRAY_ELEMENT_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return ZEND_ADD_ARRAY_ELEMENT_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
#endif
}
}
-static int ZEND_FASTCALL ZEND_UNSET_DIM_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_UNSET_DIM_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
+
zval *container;
zval *offset;
zend_ulong hval;
ZVAL_DEREF(container);
}
SEPARATE_ZVAL_NOREF(container);
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ offset = opline->op2.zv;
if (IS_UNUSED != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
HashTable *ht = Z_ARRVAL_P(container);
zend_hash_index_del(ht, hval);
break;
case IS_STRING:
- if (IS_TMP_VAR != IS_CONST) {
+ if (IS_CONST != IS_CONST) {
if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
goto num_index_dim;
}
zend_error(E_WARNING, "Illegal offset type in unset");
break;
}
- zval_ptr_dtor_nogc(free_op2);
+
} else if (IS_UNUSED == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use object as array");
}
-//??? if (IS_TMP_VAR == IS_CONST) {
+//??? if (IS_CONST == IS_CONST) {
//??? zval_copy_ctor(offset);
//??? }
Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+
} else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
ZEND_VM_CONTINUE(); /* bailed out before */
} else {
- zval_ptr_dtor_nogc(free_op2);
+
}
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_UNSET_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_UNSET_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
+
zval *container;
zval *offset;
if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
}
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ offset = opline->op2.zv;
if (IS_UNUSED != IS_UNUSED) {
ZVAL_DEREF(container);
}
if (IS_UNUSED == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
if (Z_OBJ_HT_P(container)->unset_property) {
- Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+ Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
} else {
zend_error(E_NOTICE, "Trying to unset property of non-object");
}
}
- zval_ptr_dtor_nogc(free_op2);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
+
zval *container;
int result;
zend_ulong hval;
SAVE_OPLINE();
container = _get_obj_zval_ptr_unused(execute_data);
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ offset = opline->op2.zv;
if (IS_UNUSED != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
HashTable *ht = Z_ARRVAL_P(container);
isset_again:
if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
str = Z_STR_P(offset);
- if (IS_TMP_VAR != IS_CONST) {
+ if (IS_CONST != IS_CONST) {
if (ZEND_HANDLE_NUMERIC(str, hval)) {
goto num_index_prop;
}
result = 0;
if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
- if (IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) {
+ if (IS_CONST & (IS_CV|IS_VAR)) {
ZVAL_DEREF(offset);
}
if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
result = ((opline->extended_value & ZEND_ISSET) == 0);
}
- zval_ptr_dtor_nogc(free_op2);
ZVAL_BOOL(EX_VAR(opline->result.var), result);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
+
zval *container;
int result;
zval *offset;
SAVE_OPLINE();
container = _get_obj_zval_ptr_unused(execute_data);
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ offset = opline->op2.zv;
if (IS_UNUSED == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
- result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+ result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
} else {
zend_error(E_NOTICE, "Trying to check property of non-object");
result = 0;
result = ((opline->extended_value & ZEND_ISSET) == 0);
}
- zval_ptr_dtor_nogc(free_op2);
ZVAL_BOOL(EX_VAR(opline->result.var), result);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_YIELD_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_YIELD_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
}
/* Set the new yielded key */
- if (IS_TMP_VAR != IS_UNUSED) {
- zend_free_op free_op2;
- zval *key = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ if (IS_CONST != IS_UNUSED) {
+
+ zval *key = opline->op2.zv;
/* Consts, temporary variables and references need copying */
- if (IS_TMP_VAR == IS_CONST) {
+ if (IS_CONST == IS_CONST) {
ZVAL_DUP(&generator->key, key);
- } else if (IS_TMP_VAR == IS_TMP_VAR) {
+ } else if (IS_CONST == IS_TMP_VAR) {
ZVAL_COPY_VALUE(&generator->key, key);
- } else if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && Z_ISREF_P(key)) {
+ } else if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) && Z_ISREF_P(key)) {
ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
} else {
ZVAL_COPY_VALUE(&generator->key, key);
- if (IS_TMP_VAR == IS_CV) {
+ if (IS_CONST == IS_CV) {
if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
}
}
ZEND_VM_RETURN();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op2, free_op_data1;
zval *object = _get_obj_zval_ptr_unused(execute_data);
- zval *property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ zval *property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
zval *value;
zval *zptr;
/* here we are sure we are dealing with an object */
if (opline->extended_value == ZEND_ASSIGN_OBJ
&& EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
ZVAL_DEREF(zptr);
SEPARATE_ZVAL_NOREF(zptr);
if (opline->extended_value == ZEND_ASSIGN_OBJ) {
if (Z_OBJ_HT_P(object)->read_property) {
- z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+ z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
}
} else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
if (Z_OBJ_HT_P(object)->read_dimension) {
SEPARATE_ZVAL_IF_NOT_REF(z);
binary_op(z, z, value TSRMLS_CC);
if (opline->extended_value == ZEND_ASSIGN_OBJ) {
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+ Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
} else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op2, free_op_data1;
if (IS_UNUSED == IS_VAR && !0) {
Z_ADDREF_P(container); /* undo the effect of get_obj_zval_ptr_ptr() */
}
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else {
- zval *dim = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+ zval *dim = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- zend_fetch_dimension_address_RW(&rv, container, dim, IS_VAR TSRMLS_CC);
+ zend_fetch_dimension_address_RW(&rv, container, dim, IS_TMP_VAR TSRMLS_CC);
value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
var_ptr = Z_INDIRECT(rv);
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op2;
zval *value;
SAVE_OPLINE();
- value = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+ value = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
var_ptr = NULL;
if (IS_UNUSED == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
if (IS_UNUSED == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- } else {
- ZVAL_DEREF(var_ptr);
- SEPARATE_ZVAL_NOREF(var_ptr);
-
- binary_op(var_ptr, var_ptr, value TSRMLS_CC);
-
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
- }
- }
-
- zval_ptr_dtor_nogc(free_op2);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_VAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
- zval *object;
- zval *property;
- zval *retval;
- zval *zptr;
-
- SAVE_OPLINE();
- object = _get_obj_zval_ptr_unused(execute_data);
- property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- retval = EX_VAR(opline->result.var);
-
- if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
-
- if (IS_UNUSED != IS_UNUSED) {
- object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
- }
-
- if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- zval_ptr_dtor_nogc(free_op2);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(retval);
- }
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-
- /* here we are sure we are dealing with an object */
-
- if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
-
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
-
- incdec_op(zptr);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(retval, zptr);
- }
- } else {
- zval rv;
-
- if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
-
- if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
- zval rv;
- zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
-
- if (Z_REFCOUNT_P(z) == 0) {
- zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
- }
- ZVAL_COPY_VALUE(z, value);
- }
- if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
- SEPARATE_ZVAL_IF_NOT_REF(z);
- incdec_op(z);
- ZVAL_COPY_VALUE(retval, z);
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
- SELECTIVE_PZVAL_LOCK(retval, opline);
- zval_ptr_dtor(z);
- } else {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(retval);
- }
- }
- }
-
- zval_ptr_dtor_nogc(free_op2);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_pre_incdec_property_helper_SPEC_UNUSED_VAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_pre_incdec_property_helper_SPEC_UNUSED_VAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_VAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
- zval *object;
- zval *property;
- zval *retval;
- zval *zptr;
-
- SAVE_OPLINE();
- object = _get_obj_zval_ptr_unused(execute_data);
- property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- retval = EX_VAR(opline->result.var);
-
- if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
-
- if (IS_UNUSED != IS_UNUSED) {
- object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
- }
-
- if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- zval_ptr_dtor_nogc(free_op2);
- ZVAL_NULL(retval);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-
- /* here we are sure we are dealing with an object */
-
- if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
-
- ZVAL_DEREF(zptr);
- ZVAL_COPY_VALUE(retval, zptr);
- zval_opt_copy_ctor(zptr);
-
- incdec_op(zptr);
- } else {
- if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval rv;
- zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
- zval z_copy;
-
- if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
- zval rv;
- zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
-
- if (Z_REFCOUNT_P(z) == 0) {
- zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
- }
- ZVAL_COPY_VALUE(z, value);
- }
- ZVAL_DUP(retval, z);
- ZVAL_DUP(&z_copy, z);
- incdec_op(&z_copy);
- if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
- Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
- zval_ptr_dtor(&z_copy);
- zval_ptr_dtor(z);
- } else {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- ZVAL_NULL(retval);
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
+
+ binary_op(var_ptr, var_ptr, value TSRMLS_CC);
+
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
}
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_post_incdec_property_helper_SPEC_UNUSED_VAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
}
-static int ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_post_incdec_property_helper_SPEC_UNUSED_VAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *container;
- zend_free_op free_op2;
- zval *offset;
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
- SAVE_OPLINE();
- container = _get_obj_zval_ptr_unused(execute_data);
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+static int ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- if ((IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
- UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
- zend_error(E_NOTICE, "Trying to get property of non-object");
- ZVAL_NULL(EX_VAR(opline->result.var));
- } else {
- zval *retval;
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
- /* here we are sure we are dealing with an object */
- do {
- if (IS_VAR == IS_CONST &&
- EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
- zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
- zend_object *zobj = Z_OBJ_P(container);
+static int ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- if (EXPECTED(prop_info)) {
- retval = OBJ_PROP(zobj, prop_info->offset);
- if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- } else if (EXPECTED(zobj->properties != NULL)) {
- retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
- if (EXPECTED(retval)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- }
- }
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+static int ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- if (retval != EX_VAR(opline->result.var)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- }
- } while (0);
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
+}
- zval_ptr_dtor_nogc(free_op2);
+static int ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_W_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *property;
- zval *container;
-
- SAVE_OPLINE();
- property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- container = _get_obj_zval_ptr_unused(execute_data);
- if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
+}
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_RW_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *property;
- zval *container;
-
- SAVE_OPLINE();
- property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- container = _get_obj_zval_ptr_unused(execute_data);
- if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
+}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_YIELD_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *container;
- zend_free_op free_op2;
- zval *offset;
+ /* The generator object is stored in EX(return_value) */
+ zend_generator *generator = (zend_generator *) EX(return_value);
- SAVE_OPLINE();
- container = _get_obj_zval_ptr_unused(execute_data);
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
+ zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
+ }
- if ((IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
- UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- } else {
- zval *retval;
+ /* Destroy the previously yielded value */
+ zval_ptr_dtor(&generator->value);
- /* here we are sure we are dealing with an object */
- do {
- if (IS_VAR == IS_CONST &&
- EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
- zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
- zend_object *zobj = Z_OBJ_P(container);
+ /* Destroy the previously yielded key */
+ zval_ptr_dtor(&generator->key);
- if (EXPECTED(prop_info)) {
- retval = OBJ_PROP(zobj, prop_info->offset);
- if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- } else if (EXPECTED(zobj->properties != NULL)) {
- retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
- if (EXPECTED(retval)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
+ /* Set the new yielded value */
+ if (IS_UNUSED != IS_UNUSED) {
+
+
+ if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
+ /* Constants and temporary variables aren't yieldable by reference,
+ * but we still allow them with a notice. */
+ if (IS_UNUSED == IS_CONST || IS_UNUSED == IS_TMP_VAR) {
+ zval *value;
+
+ zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+
+ value = NULL;
+ ZVAL_COPY_VALUE(&generator->value, value);
+ if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
+
+ /* Temporary variables don't need ctor copying */
+ if (IS_UNUSED != IS_TMP_VAR) {
+ zval_opt_copy_ctor(&generator->value);
}
- }
+ } else {
+ zval *value_ptr = NULL;
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
+ }
- if (retval != EX_VAR(opline->result.var)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- }
- } while (0);
- }
+ /* If a function call result is yielded and the function did
+ * not return by reference we throw a notice. */
+ if (IS_UNUSED == IS_VAR &&
+ (value_ptr == &EG(uninitialized_zval) ||
+ (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+ !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+ zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+ } else {
+ ZVAL_MAKE_REF(value_ptr);
+ }
+ ZVAL_COPY(&generator->value, value_ptr);
- zval_ptr_dtor_nogc(free_op2);
+ }
+ } else {
+ zval *value = NULL;
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ /* Consts, temporary variables and references need copying */
+ if (IS_UNUSED == IS_CONST) {
+ ZVAL_DUP(&generator->value, value);
+ } else if (IS_UNUSED == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&generator->value, value);
+ } else if ((IS_UNUSED == IS_CV || IS_UNUSED == IS_VAR) && Z_ISREF_P(value)) {
+ ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *container;
+ } else {
+ ZVAL_COPY_VALUE(&generator->value, value);
+ if (IS_UNUSED == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+ }
+ }
+ }
+ } else {
+ /* If no value was specified yield null */
+ ZVAL_NULL(&generator->value);
+ }
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- /* Behave like FETCH_OBJ_W */
- zend_free_op free_op1, free_op2;
- zval *property;
+ /* Set the new yielded key */
+ if (IS_TMP_VAR != IS_UNUSED) {
+ zend_free_op free_op2;
+ zval *key = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- SAVE_OPLINE();
- property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- container = _get_obj_zval_ptr_unused(execute_data);
+ /* Consts, temporary variables and references need copying */
+ if (IS_TMP_VAR == IS_CONST) {
+ ZVAL_DUP(&generator->key, key);
+ } else if (IS_TMP_VAR == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&generator->key, key);
+ } else if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && Z_ISREF_P(key)) {
+ ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
- if (IS_UNUSED == IS_CONST || IS_UNUSED == IS_TMP_VAR) {
- zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
- }
- if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+ } else {
+ ZVAL_COPY_VALUE(&generator->key, key);
+ if (IS_TMP_VAR == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
+ }
}
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+
+ if (Z_TYPE(generator->key) == IS_LONG
+ && Z_LVAL(generator->key) > generator->largest_used_integer_key
+ ) {
+ generator->largest_used_integer_key = Z_LVAL(generator->key);
}
+ } else {
+ /* If no key was specified we use auto-increment keys */
+ generator->largest_used_integer_key++;
+ ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
+ }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (RETURN_VALUE_USED(opline)) {
+ /* If the return value of yield is used set the send
+ * target and initialize it to NULL */
+ generator->send_target = EX_VAR(opline->result.var);
+ ZVAL_NULL(generator->send_target);
} else {
- return ZEND_FETCH_OBJ_R_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ generator->send_target = NULL;
}
+
+ /* We increment to the next op, so we are at the correct position when the
+ * generator is resumed. */
+ ZEND_VM_INC_OPCODE();
+
+ /* The GOTO VM uses a local opline variable. We need to set the opline
+ * variable in execute_data so we don't resume at an old position. */
+ SAVE_OPLINE();
+
+ ZEND_VM_RETURN();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *container, *property;
+ return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
- SAVE_OPLINE();
- container = _get_obj_zval_ptr_unused(execute_data);
- property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op2, free_op_data1;
+ zval *object = _get_obj_zval_ptr_unused(execute_data);
+ zval *property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ zval *value;
+ zval *zptr;
- if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
}
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+
+ if (IS_UNUSED != IS_UNUSED) {
+ object = make_real_object(object TSRMLS_CC);
}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-static int ZEND_FASTCALL ZEND_ASSIGN_OBJ_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
- zval *object;
- zval *property_name;
+ if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ zend_error(E_WARNING, "Attempt to assign property of non-object");
+ zval_ptr_dtor_nogc(free_op2);
+ FREE_OP(free_op_data1);
- SAVE_OPLINE();
- object = _get_obj_zval_ptr_unused(execute_data);
- property_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
+ /* here we are sure we are dealing with an object */
+ if (opline->extended_value == ZEND_ASSIGN_OBJ
+ && EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
- if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ ZVAL_DEREF(zptr);
+ SEPARATE_ZVAL_NOREF(zptr);
+
+ binary_op(zptr, zptr, value TSRMLS_CC);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), zptr);
+ }
+ } else {
+ zval *z = NULL;
+ zval rv;
+
+ if (opline->extended_value == ZEND_ASSIGN_OBJ) {
+ if (Z_OBJ_HT_P(object)->read_property) {
+ z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+ }
+ } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
+ if (Z_OBJ_HT_P(object)->read_dimension) {
+ z = Z_OBJ_HT_P(object)->read_dimension(object, property, BP_VAR_R, &rv TSRMLS_CC);
+ }
+ }
+ if (z) {
+ if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+ zval rv;
+ zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+
+ if (Z_REFCOUNT_P(z) == 0) {
+ zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
+ }
+ ZVAL_COPY_VALUE(z, value);
+ }
+//??? if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
+ SEPARATE_ZVAL_IF_NOT_REF(z);
+ binary_op(z, z, value TSRMLS_CC);
+ if (opline->extended_value == ZEND_ASSIGN_OBJ) {
+ Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+ } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
+ Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
+ }
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), z);
+ }
+ zval_ptr_dtor(z);
+ } else {
+ zend_error(E_WARNING, "Attempt to assign property of non-object");
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ }
+ }
+
+ zval_ptr_dtor_nogc(free_op2);
+ FREE_OP(free_op_data1);
}
- zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_UNUSED, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
/* assign_obj has two opcodes! */
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ADD_VAR_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
- zval *str = EX_VAR(opline->result.var);
- zval *var;
- zval var_copy;
- int use_copy = 0;
+ zend_free_op free_op2, free_op_data1;
+ zval *var_ptr, rv;
+ zval *value, *container;
SAVE_OPLINE();
- var = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
- if (IS_UNUSED == IS_UNUSED) {
- /* Initialize for erealloc in add_string_to_string */
- ZVAL_EMPTY_STRING(str);
+ container = _get_obj_zval_ptr_unused(execute_data);
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
-
- if (Z_TYPE_P(var) != IS_STRING) {
- if (IS_VAR != IS_TMP_VAR) {
- ZVAL_DEREF(var);
+ if (IS_UNUSED != IS_UNUSED) {
+ ZVAL_DEREF(container);
+ }
+ if (IS_UNUSED == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ if (IS_UNUSED == IS_VAR && !0) {
+ Z_ADDREF_P(container); /* undo the effect of get_obj_zval_ptr_ptr() */
}
- if (Z_TYPE_P(var) != IS_STRING) {
- use_copy = zend_make_printable_zval(var, &var_copy TSRMLS_CC);
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else {
+ zval *dim = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
- if (use_copy) {
- var = &var_copy;
- }
- }
+ zend_fetch_dimension_address_RW(&rv, container, dim, IS_VAR TSRMLS_CC);
+ value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+ ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+ var_ptr = Z_INDIRECT(rv);
}
- add_string_to_string(str, str, var);
- if (use_copy) {
- zend_string_release(Z_STR_P(var));
+ if (UNEXPECTED(var_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
}
- /* original comment, possibly problematic:
- * FREE_OP is missing intentionally here - we're always working on the same temporary variable
- * (Zeev): I don't think it's problematic, we only use variables
- * which aren't affected by FREE_OP(Ts, )'s anyway, unless they're
- * string offsets or overloaded objects
- */
+
+ if (UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
+
+ binary_op(var_ptr, var_ptr, value TSRMLS_CC);
+
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+ }
+ }
+
zval_ptr_dtor_nogc(free_op2);
+ FREE_OP(free_op_data1);
CHECK_EXCEPTION();
+ ZEND_VM_INC_OPCODE();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *function_name;
zend_free_op free_op2;
- zval *object;
- zend_function *fbc;
- zend_class_entry *called_scope;
- zend_object *obj;
+ zval *var_ptr;
+ zval *value;
SAVE_OPLINE();
+ value = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+ var_ptr = NULL;
- function_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
- if (IS_VAR != IS_CONST &&
- UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- zend_error_noreturn(E_ERROR, "Method name must be a string");
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
}
- object = _get_obj_zval_ptr_unused(execute_data);
-
- if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- uint32_t nesting = 1;
-
- if (UNEXPECTED(EG(exception) != NULL)) {
- zval_ptr_dtor_nogc(free_op2);
- HANDLE_EXCEPTION();
- }
-
- zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s", Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
- zval_ptr_dtor_nogc(free_op2);
-
- if (EG(exception) != NULL) {
- HANDLE_EXCEPTION();
- }
-
- /* No exception raised: Skip over arguments until fcall opcode with correct
- * nesting level. Return NULL (except when return value unused) */
- do {
- opline++;
- if (opline->opcode == ZEND_INIT_FCALL ||
- opline->opcode == ZEND_INIT_FCALL_BY_NAME ||
- opline->opcode == ZEND_INIT_NS_FCALL_BY_NAME ||
- opline->opcode == ZEND_INIT_METHOD_CALL ||
- opline->opcode == ZEND_INIT_STATIC_METHOD_CALL ||
- opline->opcode == ZEND_INIT_USER_CALL ||
- opline->opcode == ZEND_NEW
- ) {
- nesting++;
- } else if (opline->opcode == ZEND_DO_FCALL) {
- nesting--;
- }
- } while (nesting);
-
- if (RETURN_VALUE_USED(opline)) {
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
ZVAL_NULL(EX_VAR(opline->result.var));
}
+ } else {
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
- /* We've skipped EXT_FCALL_BEGIND, so also skip the ending opcode */
- if ((opline + 1)->opcode == ZEND_EXT_FCALL_END) {
- opline++;
- }
- ZEND_VM_JMP(++opline);
- }
-
- obj = Z_OBJ_P(object);
- called_scope = obj->ce;
-
- if (IS_VAR != IS_CONST ||
- EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
- zend_object *orig_obj = obj;
-
- if (UNEXPECTED(obj->handlers->get_method == NULL)) {
- zend_error_noreturn(E_ERROR, "Object does not support method calls");
- }
+ binary_op(var_ptr, var_ptr, value TSRMLS_CC);
- /* First, locate the function. */
- fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_VAR == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
- if (UNEXPECTED(fbc == NULL)) {
- zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
- }
- if (IS_VAR == IS_CONST &&
- EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
- EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
- EXPECTED(obj == orig_obj)) {
- CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope, fbc);
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
}
}
- if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_STATIC) != 0)) {
- obj = NULL;
- } else {
- GC_REFCOUNT(obj)++; /* For $this pointer */
- }
-
- EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
- fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
-
zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- zval *array;
- uint32_t size;
USE_OPLINE
- array = EX_VAR(opline->result.var);
- if (IS_UNUSED != IS_UNUSED) {
- size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
- } else {
- size = 0;
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
- ZVAL_NEW_ARR(array);
- zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
+}
- if (IS_UNUSED != IS_UNUSED) {
- /* Explicitly initialize array as not-packed if flag is set */
- if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
- zend_hash_real_init(Z_ARRVAL_P(array), 0);
- }
- }
+static int ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- if (IS_UNUSED == IS_UNUSED) {
- ZEND_VM_NEXT_OPCODE();
-#if 0 || IS_UNUSED != IS_UNUSED
- } else {
- return ZEND_ADD_ARRAY_ELEMENT_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-#endif
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_UNSET_DIM_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
- zval *container;
- zval *offset;
- zend_ulong hval;
-
- SAVE_OPLINE();
- container = _get_obj_zval_ptr_unused(execute_data);
- if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
- }
- if (IS_UNUSED != IS_UNUSED) {
- ZVAL_DEREF(container);
- }
- SEPARATE_ZVAL_NOREF(container);
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_UNUSED != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
- HashTable *ht = Z_ARRVAL_P(container);
-offset_again:
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- zend_hash_index_del(ht, hval);
- break;
- case IS_LONG:
- hval = Z_LVAL_P(offset);
-num_index_dim:
- zend_hash_index_del(ht, hval);
- break;
- case IS_STRING:
- if (IS_VAR != IS_CONST) {
- if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
- goto num_index_dim;
- }
- }
- if (ht == &EG(symbol_table).ht) {
- zend_delete_global_variable(Z_STR_P(offset) TSRMLS_CC);
- } else {
- zend_hash_del(ht, Z_STR_P(offset));
- }
- break;
- case IS_NULL:
- zend_hash_del(ht, STR_EMPTY_ALLOC());
- break;
- case IS_FALSE:
- hval = 0;
- goto num_index_dim;
- case IS_TRUE:
- hval = 1;
- goto num_index_dim;
- case IS_RESOURCE:
- hval = Z_RES_HANDLE_P(offset);
- goto num_index_dim;
- case IS_REFERENCE:
- offset = Z_REFVAL_P(offset);
- goto offset_again;
- break;
- default:
- zend_error(E_WARNING, "Illegal offset type in unset");
- break;
- }
- zval_ptr_dtor_nogc(free_op2);
- } else if (IS_UNUSED == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use object as array");
- }
-//??? if (IS_VAR == IS_CONST) {
-//??? zval_copy_ctor(offset);
-//??? }
- Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
- ZEND_VM_CONTINUE(); /* bailed out before */
- } else {
- zval_ptr_dtor_nogc(free_op2);
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_UNSET_OBJ_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
- zval *container;
- zval *offset;
- SAVE_OPLINE();
- container = _get_obj_zval_ptr_unused(execute_data);
- if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+}
- if (IS_UNUSED != IS_UNUSED) {
- ZVAL_DEREF(container);
- }
- if (IS_UNUSED == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
- if (Z_OBJ_HT_P(container)->unset_property) {
- Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to unset property of non-object");
- }
- }
- zval_ptr_dtor_nogc(free_op2);
+static int ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
- zval *container;
- int result;
- zend_ulong hval;
- zval *offset;
- SAVE_OPLINE();
- container = _get_obj_zval_ptr_unused(execute_data);
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
- if (IS_UNUSED != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
- HashTable *ht = Z_ARRVAL_P(container);
- zval *value;
- zend_string *str;
+static int ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
-isset_again:
- if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
- str = Z_STR_P(offset);
- if (IS_VAR != IS_CONST) {
- if (ZEND_HANDLE_NUMERIC(str, hval)) {
- goto num_index_prop;
- }
- }
-str_index_prop:
- value = zend_hash_find_ind(ht, str);
- } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
- hval = Z_LVAL_P(offset);
-num_index_prop:
- value = zend_hash_index_find(ht, hval);
- } else {
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- goto num_index_prop;
- case IS_NULL:
- str = STR_EMPTY_ALLOC();
- goto str_index_prop;
- case IS_FALSE:
- hval = 0;
- goto num_index_prop;
- case IS_TRUE:
- hval = 1;
- goto num_index_prop;
- case IS_RESOURCE:
- hval = Z_RES_HANDLE_P(offset);
- goto num_index_prop;
- case IS_REFERENCE:
- offset = Z_REFVAL_P(offset);
- goto isset_again;
- default:
- zend_error(E_WARNING, "Illegal offset type in isset or empty");
- value = NULL;
- break;
- }
- }
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
- if (opline->extended_value & ZEND_ISSET) {
- /* > IS_NULL means not IS_UNDEF and not IS_NULL */
- result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
- }
- } else if (IS_UNUSED == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
- result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to check element of non-array");
- result = 0;
- }
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
- }
- } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
- zval tmp;
+static int ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- result = 0;
- if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
- if (IS_VAR == IS_CV || IS_VAR == IS_VAR) {
- ZVAL_DEREF(offset);
- }
- if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
- || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
- && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
- ZVAL_DUP(&tmp, offset);
- convert_to_long(&tmp);
- offset = &tmp;
- }
- }
- if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
- if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
- if ((opline->extended_value & ZEND_ISSET) ||
- Z_STRVAL_P(container)[offset->value.lval] != '0') {
- result = 1;
- }
- }
- }
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
- }
- } else {
- result = ((opline->extended_value & ZEND_ISSET) == 0);
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
+}
- zval_ptr_dtor_nogc(free_op2);
- ZVAL_BOOL(EX_VAR(opline->result.var), result);
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
- zval *container;
- int result;
- zval *offset;
-
- SAVE_OPLINE();
- container = _get_obj_zval_ptr_unused(execute_data);
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_UNUSED == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
- result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to check property of non-object");
- result = 0;
- }
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
- }
- } else {
- result = ((opline->extended_value & ZEND_ISSET) == 0);
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
+}
- zval_ptr_dtor_nogc(free_op2);
- ZVAL_BOOL(EX_VAR(opline->result.var), result);
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
}
static int ZEND_FASTCALL ZEND_YIELD_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
}
if (Z_TYPE_P(var) != IS_STRING) {
- if (IS_CV != IS_TMP_VAR) {
- ZVAL_DEREF(var);
- }
- if (Z_TYPE_P(var) != IS_STRING) {
- use_copy = zend_make_printable_zval(var, &var_copy TSRMLS_CC);
+ use_copy = zend_make_printable_zval(var, &var_copy TSRMLS_CC);
- if (use_copy) {
- var = &var_copy;
- }
+ if (use_copy) {
+ var = &var_copy;
}
}
add_string_to_string(str, str, var);
result = 0;
if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
- if (IS_CV == IS_CV || IS_CV == IS_VAR) {
+ if (IS_CV & (IS_CV|IS_VAR)) {
ZVAL_DEREF(offset);
}
if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
static int ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_binary_assign_op_helper_SPEC_UNUSED_CV(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_BW_NOT_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
-
- SAVE_OPLINE();
- bitwise_not_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC) TSRMLS_CC);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_BOOL_NOT_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
-
- SAVE_OPLINE();
- boolean_not_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC) TSRMLS_CC);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_PRE_INC_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- zval *var_ptr;
-
- SAVE_OPLINE();
- var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
-
- if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
-
- if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
- fast_increment_function(var_ptr);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
- }
- ZEND_VM_NEXT_OPCODE();
- }
-
- if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-
- ZVAL_DEREF(var_ptr);
- SEPARATE_ZVAL_NOREF(var_ptr);
-
- increment_function(var_ptr);
-
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
- }
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ return zend_binary_assign_op_helper_SPEC_UNUSED_CV(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_PRE_DEC_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_TMPVAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
- zval *var_ptr;
+ zend_free_op free_op2;
+ zval *object;
+ zval *property;
+ zval *retval;
+ zval *zptr;
SAVE_OPLINE();
- var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+ object = _get_obj_zval_ptr_unused(execute_data);
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ retval = EX_VAR(opline->result.var);
- if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
}
- if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
- fast_decrement_function(var_ptr);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
- }
- ZEND_VM_NEXT_OPCODE();
+ if (IS_UNUSED != IS_UNUSED) {
+ object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
}
- if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ zval_ptr_dtor_nogc(free_op2);
if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
+ ZVAL_NULL(retval);
}
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
- ZVAL_DEREF(var_ptr);
- SEPARATE_ZVAL_NOREF(var_ptr);
-
- decrement_function(var_ptr);
-
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
- }
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ /* here we are sure we are dealing with an object */
-static int ZEND_FASTCALL ZEND_POST_INC_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
- zval *var_ptr;
+ ZVAL_DEREF(zptr);
+ SEPARATE_ZVAL_NOREF(zptr);
- SAVE_OPLINE();
- var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+ incdec_op(zptr);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(retval, zptr);
+ }
+ } else {
+ zval rv;
- if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
+ if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
+ zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
- if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
- fast_increment_function(var_ptr);
- ZEND_VM_NEXT_OPCODE();
- }
+ if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
+ zval rv;
+ zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (Z_REFCOUNT_P(z) == 0) {
+ zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
+ }
+ ZVAL_COPY_VALUE(z, value);
+ }
+ if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
+ SEPARATE_ZVAL_IF_NOT_REF(z);
+ incdec_op(z);
+ ZVAL_COPY_VALUE(retval, z);
+ Z_OBJ_HT_P(object)->write_property(object, property, z, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+ SELECTIVE_PZVAL_LOCK(retval, opline);
+ zval_ptr_dtor(z);
+ } else {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(retval);
+ }
+ }
}
- ZVAL_DEREF(var_ptr);
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
- zval_opt_copy_ctor(var_ptr);
-
- increment_function(var_ptr);
+ zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_POST_DEC_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- USE_OPLINE
+ return zend_pre_incdec_property_helper_SPEC_UNUSED_TMPVAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
- zval *var_ptr;
+static int ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_pre_incdec_property_helper_SPEC_UNUSED_TMPVAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_TMPVAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op2;
+ zval *object;
+ zval *property;
+ zval *retval;
+ zval *zptr;
SAVE_OPLINE();
- var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+ object = _get_obj_zval_ptr_unused(execute_data);
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ retval = EX_VAR(opline->result.var);
- if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
}
- if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
- fast_decrement_function(var_ptr);
- ZEND_VM_NEXT_OPCODE();
+ if (IS_UNUSED != IS_UNUSED) {
+ object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
}
- if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
- ZVAL_NULL(EX_VAR(opline->result.var));
+ if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ zval_ptr_dtor_nogc(free_op2);
+ ZVAL_NULL(retval);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
- ZVAL_DEREF(var_ptr);
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
- zval_opt_copy_ctor(var_ptr);
+ /* here we are sure we are dealing with an object */
- decrement_function(var_ptr);
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ ZVAL_DEREF(zptr);
+ ZVAL_COPY_VALUE(retval, zptr);
+ zval_opt_copy_ctor(zptr);
-static int ZEND_FASTCALL ZEND_ECHO_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ incdec_op(zptr);
+ } else {
+ if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
+ zval rv;
+ zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+ zval z_copy;
- zval *z;
+ if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
+ zval rv;
+ zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
- SAVE_OPLINE();
- z = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ if (Z_REFCOUNT_P(z) == 0) {
+ zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
+ }
+ ZVAL_COPY_VALUE(z, value);
+ }
+ ZVAL_DUP(retval, z);
+ ZVAL_DUP(&z_copy, z);
+ incdec_op(&z_copy);
+ if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
+ Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+ zval_ptr_dtor(&z_copy);
+ zval_ptr_dtor(z);
+ } else {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ ZVAL_NULL(retval);
+ }
+ }
- zend_print_variable(z TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_PRINT_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- USE_OPLINE
+ return zend_post_incdec_property_helper_SPEC_UNUSED_TMPVAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
- ZVAL_LONG(EX_VAR(opline->result.var), 1);
- return ZEND_ECHO_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+static int ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_post_incdec_property_helper_SPEC_UNUSED_TMPVAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_JMPZ_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *val;
+ zval *container;
+ zend_free_op free_op2;
+ zval *offset;
SAVE_OPLINE();
- val = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-
- if (IS_CV == IS_TMP_VAR) {
- if (Z_TYPE_P(val) == IS_TRUE) {
- ZEND_VM_SET_OPCODE(opline + 1);
- ZEND_VM_CONTINUE();
- } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
- ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
- ZEND_VM_CONTINUE();
- }
- }
+ container = _get_obj_zval_ptr_unused(execute_data);
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (i_zend_is_true(val TSRMLS_CC)) {
- opline++;
+ if ((IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+ UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+ zend_error(E_NOTICE, "Trying to get property of non-object");
+ ZVAL_NULL(EX_VAR(opline->result.var));
} else {
- opline = opline->op2.jmp_addr;
- }
+ zval *retval;
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
+ /* here we are sure we are dealing with an object */
+ do {
+ if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
+ EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
+ zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
+ zend_object *zobj = Z_OBJ_P(container);
+
+ if (EXPECTED(prop_info)) {
+ retval = OBJ_PROP(zobj, prop_info->offset);
+ if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
+ }
+ } else if (EXPECTED(zobj->properties != NULL)) {
+ retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
+ if (EXPECTED(retval)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
+ }
+ }
+ }
+
+ retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+
+ if (retval != EX_VAR(opline->result.var)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ }
+ } while (0);
}
- ZEND_VM_JMP(opline);
+
+ zval_ptr_dtor_nogc(free_op2);
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_JMPNZ_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_W_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
- zval *val;
+ zend_free_op free_op1, free_op2;
+ zval *property;
+ zval *container;
SAVE_OPLINE();
- val = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_CV == IS_TMP_VAR) {
- if (Z_TYPE_P(val) == IS_TRUE) {
- ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
- ZEND_VM_CONTINUE();
- } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
- ZEND_VM_SET_OPCODE(opline + 1);
- ZEND_VM_CONTINUE();
- }
+ container = _get_obj_zval_ptr_unused(execute_data);
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
}
- if (i_zend_is_true(val TSRMLS_CC)) {
- opline = opline->op2.jmp_addr;
- } else {
- opline++;
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- ZEND_VM_JMP(opline);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_JMPZNZ_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_RW_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
- zval *val;
+ zend_free_op free_op1, free_op2;
+ zval *property;
+ zval *container;
SAVE_OPLINE();
- val = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ container = _get_obj_zval_ptr_unused(execute_data);
- if (IS_CV == IS_TMP_VAR) {
- if (EXPECTED(Z_TYPE_P(val) == IS_TRUE)) {
- ZEND_VM_SET_RELATIVE_OPCODE(opline, opline->extended_value);
- ZEND_VM_CONTINUE();
- } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
- ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
- ZEND_VM_CONTINUE();
- }
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
}
-
- if (i_zend_is_true(val TSRMLS_CC)) {
- opline = (zend_op*)(((char*)opline) + opline->extended_value);
- } else {
- opline = opline->op2.jmp_addr;
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- ZEND_VM_JMP(opline);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_JMPZ_EX_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *val;
+ zval *container;
+ zend_free_op free_op2;
+ zval *offset;
SAVE_OPLINE();
- val = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ container = _get_obj_zval_ptr_unused(execute_data);
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_CV == IS_TMP_VAR) {
- if (Z_TYPE_P(val) == IS_TRUE) {
- ZVAL_TRUE(EX_VAR(opline->result.var));
- ZEND_VM_SET_OPCODE(opline + 1);
- ZEND_VM_CONTINUE();
- } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
- ZVAL_FALSE(EX_VAR(opline->result.var));
- ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
- ZEND_VM_CONTINUE();
- }
- }
+ if ((IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+ UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ } else {
+ zval *retval;
- if (i_zend_is_true(val TSRMLS_CC)) {
+ /* here we are sure we are dealing with an object */
+ do {
+ if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
+ EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
+ zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
+ zend_object *zobj = Z_OBJ_P(container);
- ZVAL_TRUE(EX_VAR(opline->result.var));
- opline++;
- } else {
+ if (EXPECTED(prop_info)) {
+ retval = OBJ_PROP(zobj, prop_info->offset);
+ if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
+ }
+ } else if (EXPECTED(zobj->properties != NULL)) {
+ retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
+ if (EXPECTED(retval)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
+ }
+ }
+ }
- ZVAL_FALSE(EX_VAR(opline->result.var));
- opline = opline->op2.jmp_addr;
- }
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
+ retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+
+ if (retval != EX_VAR(opline->result.var)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ }
+ } while (0);
}
- ZEND_VM_JMP(opline);
+
+ zval_ptr_dtor_nogc(free_op2);
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_JMPNZ_EX_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *container;
- zval *val;
+ if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+ /* Behave like FETCH_OBJ_W */
+ zend_free_op free_op1, free_op2;
+ zval *property;
- SAVE_OPLINE();
- val = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ SAVE_OPLINE();
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ container = _get_obj_zval_ptr_unused(execute_data);
- if (IS_CV == IS_TMP_VAR) {
- if (Z_TYPE_P(val) == IS_TRUE) {
- ZVAL_TRUE(EX_VAR(opline->result.var));
- ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
- ZEND_VM_CONTINUE();
- } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
- ZVAL_FALSE(EX_VAR(opline->result.var));
- ZEND_VM_SET_OPCODE(opline + 1);
- ZEND_VM_CONTINUE();
+ if (IS_UNUSED == IS_CONST || IS_UNUSED == IS_TMP_VAR) {
+ zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+ }
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+ }
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
- }
- if (i_zend_is_true(val TSRMLS_CC)) {
- ZVAL_TRUE(EX_VAR(opline->result.var));
- opline = opline->op2.jmp_addr;
- } else {
- ZVAL_FALSE(EX_VAR(opline->result.var));
- opline++;
- }
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ } else {
+ return ZEND_FETCH_OBJ_R_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
- ZEND_VM_JMP(opline);
}
-static int ZEND_FASTCALL ZEND_RETURN_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *retval_ptr;
-
+ zend_free_op free_op1, free_op2;
+ zval *container, *property;
SAVE_OPLINE();
- retval_ptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-
- if (!EX(return_value)) {
-
- } else {
- if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
- if (IS_CV == IS_CONST) {
- if (UNEXPECTED(Z_OPT_COPYABLE_P(EX(return_value)))) {
- zval_copy_ctor_func(EX(return_value));
- }
- }
- } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(retval_ptr)) {
- ZVAL_COPY(EX(return_value), Z_REFVAL_P(retval_ptr));
+ container = _get_obj_zval_ptr_unused(execute_data);
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- } else {
- ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
- if (IS_CV == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(retval_ptr)) Z_ADDREF_P(retval_ptr);
- }
- }
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
}
- return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ }
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_RETURN_BY_REF_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_OBJ_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *retval_ptr;
-
+ zend_free_op free_op2;
+ zval *object;
+ zval *property_name;
SAVE_OPLINE();
+ object = _get_obj_zval_ptr_unused(execute_data);
+ property_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- do {
- if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR ||
- (IS_CV == IS_VAR && opline->extended_value == ZEND_RETURNS_VALUE)) {
- /* Not supposed to happen, but we'll allow it */
- zend_error(E_NOTICE, "Only variable references should be returned by reference");
-
- retval_ptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- if (!EX(return_value)) {
- if (IS_CV == IS_TMP_VAR) {
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ }
+ zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_UNUSED, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
- }
- } else {
- ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
- Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
- if (IS_CV != IS_TMP_VAR) {
- zval_opt_copy_ctor_no_imm(EX(return_value));
- }
- }
- break;
- }
+ /* assign_obj has two opcodes! */
+ CHECK_EXCEPTION();
+ ZEND_VM_INC_OPCODE();
+ ZEND_VM_NEXT_OPCODE();
+}
- retval_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+static int ZEND_FASTCALL ZEND_ADD_VAR_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op2;
+ zval *str = EX_VAR(opline->result.var);
+ zval *var;
+ zval var_copy;
+ int use_copy = 0;
- if (IS_CV == IS_VAR && UNEXPECTED(retval_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot return string offsets by reference");
- }
+ SAVE_OPLINE();
+ var = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_CV == IS_VAR) {
- if (retval_ptr == &EG(uninitialized_zval) ||
- (opline->extended_value == ZEND_RETURNS_FUNCTION &&
- !(Z_VAR_FLAGS_P(retval_ptr) & IS_VAR_RET_REF))) {
- zend_error(E_NOTICE, "Only variable references should be returned by reference");
- if (EX(return_value)) {
- ZVAL_NEW_REF(EX(return_value), retval_ptr);
- Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
- if (Z_REFCOUNTED_P(retval_ptr)) Z_ADDREF_P(retval_ptr);
- }
- break;
- }
- }
+ if (IS_UNUSED == IS_UNUSED) {
+ /* Initialize for erealloc in add_string_to_string */
+ ZVAL_EMPTY_STRING(str);
+ }
- if (EX(return_value)) {
- ZVAL_MAKE_REF(retval_ptr);
- Z_ADDREF_P(retval_ptr);
- ZVAL_REF(EX(return_value), Z_REF_P(retval_ptr));
- Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
+ if (Z_TYPE_P(var) != IS_STRING) {
+ use_copy = zend_make_printable_zval(var, &var_copy TSRMLS_CC);
+
+ if (use_copy) {
+ var = &var_copy;
}
- } while (0);
+ }
+ add_string_to_string(str, str, var);
- return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ if (use_copy) {
+ zend_string_release(Z_STR_P(var));
+ }
+ /* original comment, possibly problematic:
+ * FREE_OP is missing intentionally here - we're always working on the same temporary variable
+ * (Zeev): I don't think it's problematic, we only use variables
+ * which aren't affected by FREE_OP(Ts, )'s anyway, unless they're
+ * string offsets or overloaded objects
+ */
+ zval_ptr_dtor_nogc(free_op2);
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_THROW_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *value;
-
+ zval *function_name;
+ zend_free_op free_op2;
+ zval *object;
+ zend_function *fbc;
+ zend_class_entry *called_scope;
+ zend_object *obj;
SAVE_OPLINE();
- value = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_CONST || UNEXPECTED(Z_TYPE_P(value) != IS_OBJECT)) {
+ function_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST &&
+ UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
if (UNEXPECTED(EG(exception) != NULL)) {
HANDLE_EXCEPTION();
}
- zend_error_noreturn(E_ERROR, "Can only throw objects");
+ zend_error_noreturn(E_ERROR, "Method name must be a string");
}
- zend_exception_save(TSRMLS_C);
- if (IS_CV != IS_TMP_VAR) {
- if (Z_REFCOUNTED_P(value)) Z_ADDREF_P(value);
- }
+ object = _get_obj_zval_ptr_unused(execute_data);
- zend_throw_exception_object(value TSRMLS_CC);
- zend_exception_restore(TSRMLS_C);
+ if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ uint32_t nesting = 1;
- HANDLE_EXCEPTION();
-}
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ zval_ptr_dtor_nogc(free_op2);
+ HANDLE_EXCEPTION();
+ }
-static int ZEND_FASTCALL ZEND_SEND_VAR_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval *varptr, *arg;
+ zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s", Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
+ zval_ptr_dtor_nogc(free_op2);
+ if (EG(exception) != NULL) {
+ HANDLE_EXCEPTION();
+ }
- varptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
- ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
- if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(varptr)) {
- ZVAL_COPY(arg, Z_REFVAL_P(varptr));
+ /* No exception raised: Skip over arguments until fcall opcode with correct
+ * nesting level. Return NULL (except when return value unused) */
+ do {
+ opline++;
+ if (opline->opcode == ZEND_INIT_FCALL ||
+ opline->opcode == ZEND_INIT_FCALL_BY_NAME ||
+ opline->opcode == ZEND_INIT_NS_FCALL_BY_NAME ||
+ opline->opcode == ZEND_INIT_METHOD_CALL ||
+ opline->opcode == ZEND_INIT_STATIC_METHOD_CALL ||
+ opline->opcode == ZEND_INIT_USER_CALL ||
+ opline->opcode == ZEND_NEW
+ ) {
+ nesting++;
+ } else if (opline->opcode == ZEND_DO_FCALL) {
+ nesting--;
+ }
+ } while (nesting);
- } else {
- ZVAL_COPY_VALUE(arg, varptr);
- if (IS_CV == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(arg)) Z_ADDREF_P(arg);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+
+ /* We've skipped EXT_FCALL_BEGIND, so also skip the ending opcode */
+ if ((opline + 1)->opcode == ZEND_EXT_FCALL_END) {
+ opline++;
}
+ ZEND_VM_JMP(++opline);
}
- ZEND_VM_NEXT_OPCODE();
-}
-static int ZEND_FASTCALL ZEND_SEND_VAR_NO_REF_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ obj = Z_OBJ_P(object);
+ called_scope = obj->ce;
- zval *varptr, *arg;
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST ||
+ EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
+ zend_object *orig_obj = obj;
- SAVE_OPLINE();
+ if (UNEXPECTED(obj->handlers->get_method == NULL)) {
+ zend_error_noreturn(E_ERROR, "Object does not support method calls");
+ }
- if (!(opline->extended_value & ZEND_ARG_COMPILE_TIME_BOUND)) {
- if (!ARG_SHOULD_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
- return ZEND_SEND_VAR_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ /* First, locate the function. */
+ fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
+ if (UNEXPECTED(fbc == NULL)) {
+ zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
+ }
+ if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
+ EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
+ EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
+ EXPECTED(obj == orig_obj)) {
+ CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope, fbc);
}
}
- varptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- if ((!(opline->extended_value & ZEND_ARG_SEND_FUNCTION) ||
- (Z_VAR_FLAGS_P(varptr) & IS_VAR_RET_REF)) &&
- (Z_ISREF_P(varptr) || Z_TYPE_P(varptr) == IS_OBJECT)) {
-
- ZVAL_MAKE_REF(varptr);
- if (IS_CV == IS_CV) {
- Z_ADDREF_P(varptr);
- }
+ if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_STATIC) != 0)) {
+ obj = NULL;
} else {
- if ((opline->extended_value & ZEND_ARG_COMPILE_TIME_BOUND) ?
- !(opline->extended_value & ZEND_ARG_SEND_SILENT) :
- !ARG_MAY_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
- zend_error(E_STRICT, "Only variables should be passed by reference");
- }
+ GC_REFCOUNT(obj)++; /* For $this pointer */
}
- arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
- ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
- ZVAL_COPY_VALUE(arg, varptr);
+ EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
+ fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
+
+ zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_SEND_REF_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+ zval *array;
+ uint32_t size;
USE_OPLINE
- zval *varptr, *arg;
-
- SAVE_OPLINE();
- varptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ array = EX_VAR(opline->result.var);
+ if (IS_UNUSED != IS_UNUSED) {
+ size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
+ } else {
+ size = 0;
+ }
+ ZVAL_NEW_ARR(array);
+ zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
- if (IS_CV == IS_VAR && UNEXPECTED(varptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Only variables can be passed by reference");
+ if (IS_UNUSED != IS_UNUSED) {
+ /* Explicitly initialize array as not-packed if flag is set */
+ if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
+ zend_hash_real_init(Z_ARRVAL_P(array), 0);
+ }
}
- arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
- ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
- if (IS_CV == IS_VAR && UNEXPECTED(varptr == &EG(error_zval))) {
- ZVAL_NEW_REF(arg, &EG(uninitialized_zval));
+ if (IS_UNUSED == IS_UNUSED) {
ZEND_VM_NEXT_OPCODE();
+#if 0 || IS_UNUSED != IS_UNUSED
+ } else {
+ return ZEND_ADD_ARRAY_ELEMENT_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+#endif
}
+}
- if (Z_ISREF_P(varptr)) {
- Z_ADDREF_P(varptr);
- ZVAL_COPY_VALUE(arg, varptr);
- } else if (IS_CV == IS_VAR &&
- UNEXPECTED(Z_TYPE_P(EX_VAR(opline->op1.var)) != IS_INDIRECT)) {
- ZVAL_NEW_REF(arg, varptr);
+static int ZEND_FASTCALL ZEND_UNSET_DIM_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op2;
+ zval *container;
+ zval *offset;
+ zend_ulong hval;
+
+ SAVE_OPLINE();
+ container = _get_obj_zval_ptr_unused(execute_data);
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
+ }
+ if (IS_UNUSED != IS_UNUSED) {
+ ZVAL_DEREF(container);
+ }
+ SEPARATE_ZVAL_NOREF(container);
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+
+ if (IS_UNUSED != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
+ HashTable *ht = Z_ARRVAL_P(container);
+offset_again:
+ switch (Z_TYPE_P(offset)) {
+ case IS_DOUBLE:
+ hval = zend_dval_to_lval(Z_DVAL_P(offset));
+ zend_hash_index_del(ht, hval);
+ break;
+ case IS_LONG:
+ hval = Z_LVAL_P(offset);
+num_index_dim:
+ zend_hash_index_del(ht, hval);
+ break;
+ case IS_STRING:
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+ if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
+ goto num_index_dim;
+ }
+ }
+ if (ht == &EG(symbol_table).ht) {
+ zend_delete_global_variable(Z_STR_P(offset) TSRMLS_CC);
+ } else {
+ zend_hash_del(ht, Z_STR_P(offset));
+ }
+ break;
+ case IS_NULL:
+ zend_hash_del(ht, STR_EMPTY_ALLOC());
+ break;
+ case IS_FALSE:
+ hval = 0;
+ goto num_index_dim;
+ case IS_TRUE:
+ hval = 1;
+ goto num_index_dim;
+ case IS_RESOURCE:
+ hval = Z_RES_HANDLE_P(offset);
+ goto num_index_dim;
+ case IS_REFERENCE:
+ offset = Z_REFVAL_P(offset);
+ goto offset_again;
+ break;
+ default:
+ zend_error(E_WARNING, "Illegal offset type in unset");
+ break;
+ }
+ zval_ptr_dtor_nogc(free_op2);
+ } else if (IS_UNUSED == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use object as array");
+ }
+//??? if ((IS_TMP_VAR|IS_VAR) == IS_CONST) {
+//??? zval_copy_ctor(offset);
+//??? }
+ Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
+ ZEND_VM_CONTINUE(); /* bailed out before */
} else {
- ZVAL_NEW_REF(arg, varptr);
- Z_ADDREF_P(arg);
- ZVAL_REF(varptr, Z_REF_P(arg));
+ zval_ptr_dtor_nogc(free_op2);
}
+ CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_SEND_VAR_EX_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_UNSET_OBJ_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *varptr, *arg;
-
+ zend_free_op free_op2;
+ zval *container;
+ zval *offset;
- if (ARG_SHOULD_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
- return ZEND_SEND_REF_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ SAVE_OPLINE();
+ container = _get_obj_zval_ptr_unused(execute_data);
+ if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
}
- varptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
- ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
- if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(varptr)) {
- ZVAL_COPY(arg, Z_REFVAL_P(varptr));
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- } else {
- ZVAL_COPY_VALUE(arg, varptr);
- if (IS_CV == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(arg)) Z_ADDREF_P(arg);
+ if (IS_UNUSED != IS_UNUSED) {
+ ZVAL_DEREF(container);
+ }
+ if (IS_UNUSED == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
+ if (Z_OBJ_HT_P(container)->unset_property) {
+ Z_OBJ_HT_P(container)->unset_property(container, offset, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+ } else {
+ zend_error(E_NOTICE, "Trying to unset property of non-object");
}
}
+ zval_ptr_dtor_nogc(free_op2);
+
+ CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_SEND_USER_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *arg, *param, tmp;
-
-
- arg = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- param = ZEND_CALL_ARG(EX(call), opline->op2.num);
-
- if (ARG_SHOULD_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
- // TODO: Scalar values don't have reference counters anymore.
- // They are assumed to be 1, and they may be easily passed by
- // reference now. However, previously scalars with refcount==1
- // might be passed and with refcount>1 might not. We can support
- // only single behavior ???
-#if 0
- if (Z_REFCOUNTED_P(arg) &&
- // This solution breaks the following test (omit warning message) ???
- // Zend/tests/bug61273.phpt
- // ext/reflection/tests/bug42976.phpt
- // ext/standard/tests/general_functions/call_user_func_array_variation_001.phpt
-#else
- if (!Z_REFCOUNTED_P(arg) ||
- // This solution breaks the following test (emit warning message) ???
- // ext/pdo_sqlite/tests/pdo_005.phpt
-#endif
- (!Z_ISREF_P(arg) /*&& Z_REFCOUNT_P(arg) > 1???*/)) {
+ zend_free_op free_op2;
+ zval *container;
+ int result;
+ zend_ulong hval;
+ zval *offset;
- if (!ARG_MAY_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
+ SAVE_OPLINE();
+ container = _get_obj_zval_ptr_unused(execute_data);
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- zend_error(E_WARNING, "Parameter %d to %s%s%s() expected to be a reference, value given",
- opline->op2.num,
- EX(call)->func->common.scope ? EX(call)->func->common.scope->name->val : "",
- EX(call)->func->common.scope ? "::" : "",
- EX(call)->func->common.function_name->val);
+ if (IS_UNUSED != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
+ HashTable *ht = Z_ARRVAL_P(container);
+ zval *value;
+ zend_string *str;
- if (EX(call)->func->common.fn_flags & ZEND_ACC_CLOSURE) {
- OBJ_RELEASE((zend_object*)EX(call)->func->common.prototype);
- }
- if (Z_OBJ(EX(call)->This)) {
- OBJ_RELEASE(Z_OBJ(EX(call)->This));
+isset_again:
+ if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
+ str = Z_STR_P(offset);
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+ if (ZEND_HANDLE_NUMERIC(str, hval)) {
+ goto num_index_prop;
}
- EX(call)->func = (zend_function*)&zend_pass_function;
- EX(call)->called_scope = NULL;
- Z_OBJ(EX(call)->This) = NULL;
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
}
+str_index_prop:
+ value = zend_hash_find_ind(ht, str);
+ } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
+ hval = Z_LVAL_P(offset);
+num_index_prop:
+ value = zend_hash_index_find(ht, hval);
+ } else {
+ switch (Z_TYPE_P(offset)) {
+ case IS_DOUBLE:
+ hval = zend_dval_to_lval(Z_DVAL_P(offset));
+ goto num_index_prop;
+ case IS_NULL:
+ str = STR_EMPTY_ALLOC();
+ goto str_index_prop;
+ case IS_FALSE:
+ hval = 0;
+ goto num_index_prop;
+ case IS_TRUE:
+ hval = 1;
+ goto num_index_prop;
+ case IS_RESOURCE:
+ hval = Z_RES_HANDLE_P(offset);
+ goto num_index_prop;
+ case IS_REFERENCE:
+ offset = Z_REFVAL_P(offset);
+ goto isset_again;
+ default:
+ zend_error(E_WARNING, "Illegal offset type in isset or empty");
+ value = NULL;
+ break;
+ }
+ }
- if (Z_REFCOUNTED_P(arg)) {
- Z_DELREF_P(arg);
+ if (opline->extended_value & ZEND_ISSET) {
+ /* > IS_NULL means not IS_UNDEF and not IS_NULL */
+ result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
+ (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
+ } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+ result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
+ }
+ } else if (IS_UNUSED == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
+ result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
+ } else {
+ zend_error(E_NOTICE, "Trying to check element of non-array");
+ result = 0;
+ }
+ if ((opline->extended_value & ZEND_ISSET) == 0) {
+ result = !result;
+ }
+ } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
+ zval tmp;
+
+ result = 0;
+ if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
+ if ((IS_TMP_VAR|IS_VAR) & (IS_CV|IS_VAR)) {
+ ZVAL_DEREF(offset);
+ }
+ if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
+ || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
+ && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
+ ZVAL_DUP(&tmp, offset);
+ convert_to_long(&tmp);
+ offset = &tmp;
}
- ZVAL_DUP(&tmp, arg);
- ZVAL_NEW_REF(arg, &tmp);
- Z_ADDREF_P(arg);
- } else if (!Z_ISREF_P(arg)) {
- ZVAL_NEW_REF(arg, arg);
- Z_ADDREF_P(arg);
- } else if (Z_REFCOUNTED_P(arg)) {
- Z_ADDREF_P(arg);
}
- ZVAL_COPY_VALUE(param, arg);
- } else if (Z_ISREF_P(arg) &&
- /* don't separate references for __call */
- (EX(call)->func->common.fn_flags & ZEND_ACC_CALL_VIA_HANDLER) == 0) {
- ZVAL_DUP(param, Z_REFVAL_P(arg));
+ if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
+ if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
+ if ((opline->extended_value & ZEND_ISSET) ||
+ Z_STRVAL_P(container)[offset->value.lval] != '0') {
+ result = 1;
+ }
+ }
+ }
+ if ((opline->extended_value & ZEND_ISSET) == 0) {
+ result = !result;
+ }
} else {
- ZVAL_COPY(param, arg);
+ result = ((opline->extended_value & ZEND_ISSET) == 0);
}
- ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_BOOL_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- zval *retval = EX_VAR(opline->result.var);
-
- SAVE_OPLINE();
- /* PHP 3.0 returned "" for false and 1 for true, here we use 0 and 1 for now */
- ZVAL_BOOL(retval, i_zend_is_true(_get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC) TSRMLS_CC));
+ zval_ptr_dtor_nogc(free_op2);
+ ZVAL_BOOL(EX_VAR(opline->result.var), result);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_CLONE_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
- zval *obj;
- zend_class_entry *ce;
- zend_function *clone;
- zend_object_clone_obj_t clone_call;
+ zend_free_op free_op2;
+ zval *container;
+ int result;
+ zval *offset;
SAVE_OPLINE();
- obj = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-
- if (IS_CV == IS_CONST ||
- (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(obj) != IS_OBJECT))) {
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- zend_error_noreturn(E_ERROR, "__clone method called on non-object");
- }
+ container = _get_obj_zval_ptr_unused(execute_data);
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- ce = Z_OBJCE_P(obj);
- clone = ce ? ce->clone : NULL;
- clone_call = Z_OBJ_HT_P(obj)->clone_obj;
- if (UNEXPECTED(clone_call == NULL)) {
- if (ce) {
- zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object of class %s", ce->name->val);
+ if (IS_UNUSED == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
+ result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
} else {
- zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object");
+ zend_error(E_NOTICE, "Trying to check property of non-object");
+ result = 0;
}
- }
-
- if (ce && clone) {
- if (clone->op_array.fn_flags & ZEND_ACC_PRIVATE) {
- /* Ensure that if we're calling a private function, we're allowed to do so.
- */
- if (UNEXPECTED(ce != EG(scope))) {
- zend_error_noreturn(E_ERROR, "Call to private %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
- }
- } else if ((clone->common.fn_flags & ZEND_ACC_PROTECTED)) {
- /* Ensure that if we're calling a protected function, we're allowed to do so.
- */
- if (UNEXPECTED(!zend_check_protected(zend_get_function_root_class(clone), EG(scope)))) {
- zend_error_noreturn(E_ERROR, "Call to protected %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
- }
+ if ((opline->extended_value & ZEND_ISSET) == 0) {
+ result = !result;
}
+ } else {
+ result = ((opline->extended_value & ZEND_ISSET) == 0);
}
- if (EXPECTED(EG(exception) == NULL)) {
- ZVAL_OBJ(EX_VAR(opline->result.var), clone_call(obj TSRMLS_CC));
- if (!RETURN_VALUE_USED(opline) || UNEXPECTED(EG(exception) != NULL)) {
- OBJ_RELEASE(Z_OBJ_P(EX_VAR(opline->result.var)));
- }
- }
+ zval_ptr_dtor_nogc(free_op2);
+ ZVAL_BOOL(EX_VAR(opline->result.var), result);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_CAST_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BW_NOT_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *expr;
- zval *result = EX_VAR(opline->result.var);
SAVE_OPLINE();
- expr = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ bitwise_not_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC) TSRMLS_CC);
- switch (opline->extended_value) {
- case IS_NULL:
- /* This code is taken from convert_to_null. However, it does not seems very useful,
- * because a conversion to null always results in the same value. This could only
- * be relevant if a cast_object handler for IS_NULL has some kind of side-effect. */
-#if 0
- if (IS_CV == IS_VAR || IS_CV == IS_CV) {
- ZVAL_DEREF(expr);
- }
- if (Z_TYPE_P(expr) == IS_OBJECT && Z_OBJ_HT_P(expr)->cast_object) {
- if (Z_OBJ_HT_P(expr)->cast_object(expr, result, IS_NULL TSRMLS_CC) == SUCCESS) {
- break;
- }
- }
-#endif
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- ZVAL_NULL(result);
- break;
- case _IS_BOOL:
- ZVAL_BOOL(result, zend_is_true(expr TSRMLS_CC));
- break;
- case IS_LONG:
- ZVAL_LONG(result, zval_get_long(expr));
- break;
- case IS_DOUBLE:
- ZVAL_DOUBLE(result, zval_get_double(expr));
- break;
- case IS_STRING:
- ZVAL_STR(result, zval_get_string(expr));
- break;
- default:
- /* If value is already of correct type, return it directly */
- if (Z_TYPE_P(expr) == opline->extended_value) {
- ZVAL_COPY_VALUE(result, expr);
- if (IS_CV == IS_CONST) {
- if (UNEXPECTED(Z_OPT_COPYABLE_P(result))) {
- zval_copy_ctor_func(result);
- }
- } else if (IS_CV != IS_TMP_VAR) {
- if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
- }
+static int ZEND_FASTCALL ZEND_BOOL_NOT_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
- if (opline->extended_value == IS_ARRAY) {
- if (Z_TYPE_P(expr) != IS_OBJECT) {
- ZVAL_NEW_ARR(result);
- zend_hash_init(Z_ARRVAL_P(result), 8, NULL, ZVAL_PTR_DTOR, 0);
- if (Z_TYPE_P(expr) != IS_NULL) {
- expr = zend_hash_index_add_new(Z_ARRVAL_P(result), 0, expr);
- if (IS_CV == IS_CONST) {
- if (UNEXPECTED(Z_OPT_COPYABLE_P(expr))) {
- zval_copy_ctor_func(expr);
- }
- } else {
- if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
- }
- }
- } else {
- ZVAL_COPY_VALUE(result, expr);
- Z_ADDREF_P(result);
- convert_to_array(result);
- }
- } else {
- if (Z_TYPE_P(expr) != IS_ARRAY) {
- object_init(result);
- if (Z_TYPE_P(expr) != IS_NULL) {
- expr = zend_hash_str_add_new(Z_OBJPROP_P(result), "scalar", sizeof("scalar")-1, expr);
- if (IS_CV == IS_CONST) {
- if (UNEXPECTED(Z_OPT_COPYABLE_P(expr))) {
- zval_copy_ctor_func(expr);
- }
- } else {
- if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
- }
- }
- } else {
- ZVAL_COPY_VALUE(result, expr);
- zval_opt_copy_ctor(result);
- convert_to_object(result);
- }
- }
- }
+ SAVE_OPLINE();
+ boolean_not_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC) TSRMLS_CC);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INCLUDE_OR_EVAL_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_PRE_INC_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_op_array *new_op_array=NULL;
- zval *inc_filename;
- zval tmp_inc_filename;
- zend_bool failure_retval=0;
+ zval *var_ptr;
SAVE_OPLINE();
- inc_filename = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- ZVAL_UNDEF(&tmp_inc_filename);
- if (Z_TYPE_P(inc_filename) != IS_STRING) {
- ZVAL_STR(&tmp_inc_filename, zval_get_string(inc_filename));
- inc_filename = &tmp_inc_filename;
+ if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
}
- if (opline->extended_value != ZEND_EVAL && strlen(Z_STRVAL_P(inc_filename)) != Z_STRLEN_P(inc_filename)) {
- if (opline->extended_value == ZEND_INCLUDE_ONCE || opline->extended_value == ZEND_INCLUDE) {
- zend_message_dispatcher(ZMSG_FAILED_INCLUDE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
- } else {
- zend_message_dispatcher(ZMSG_FAILED_REQUIRE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
+ if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
+ fast_increment_function(var_ptr);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
}
- } else {
- switch (opline->extended_value) {
- case ZEND_INCLUDE_ONCE:
- case ZEND_REQUIRE_ONCE: {
- zend_file_handle file_handle;
- char *resolved_path;
-
- resolved_path = zend_resolve_path(Z_STRVAL_P(inc_filename), (int)Z_STRLEN_P(inc_filename) TSRMLS_CC);
- if (resolved_path) {
- failure_retval = zend_hash_str_exists(&EG(included_files), resolved_path, (int)strlen(resolved_path));
- } else {
- resolved_path = Z_STRVAL_P(inc_filename);
- }
+ ZEND_VM_NEXT_OPCODE();
+ }
- if (failure_retval) {
- /* do nothing, file already included */
- } else if (SUCCESS == zend_stream_open(resolved_path, &file_handle TSRMLS_CC)) {
+ if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
- if (!file_handle.opened_path) {
- file_handle.opened_path = estrdup(resolved_path);
- }
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
- if (zend_hash_str_add_empty_element(&EG(included_files), file_handle.opened_path, (int)strlen(file_handle.opened_path))) {
- new_op_array = zend_compile_file(&file_handle, (opline->extended_value==ZEND_INCLUDE_ONCE?ZEND_INCLUDE:ZEND_REQUIRE) TSRMLS_CC);
- zend_destroy_file_handle(&file_handle TSRMLS_CC);
- } else {
- zend_file_handle_dtor(&file_handle TSRMLS_CC);
- failure_retval=1;
- }
- } else {
- if (opline->extended_value == ZEND_INCLUDE_ONCE) {
- zend_message_dispatcher(ZMSG_FAILED_INCLUDE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
- } else {
- zend_message_dispatcher(ZMSG_FAILED_REQUIRE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
- }
- }
- if (resolved_path != Z_STRVAL_P(inc_filename)) {
- efree(resolved_path);
- }
- }
- break;
- case ZEND_INCLUDE:
- case ZEND_REQUIRE:
- new_op_array = compile_filename(opline->extended_value, inc_filename TSRMLS_CC);
- break;
- case ZEND_EVAL: {
- char *eval_desc = zend_make_compiled_string_description("eval()'d code" TSRMLS_CC);
+ increment_function(var_ptr);
- new_op_array = zend_compile_string(inc_filename, eval_desc TSRMLS_CC);
- efree(eval_desc);
- }
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
- }
- }
- if (Z_TYPE(tmp_inc_filename) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp_inc_filename));
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
}
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- } else if (EXPECTED(new_op_array != NULL)) {
- zval *return_value = NULL;
- zend_execute_data *call;
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- if (RETURN_VALUE_USED(opline)) {
- return_value = EX_VAR(opline->result.var);
- }
+static int ZEND_FASTCALL ZEND_PRE_DEC_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- new_op_array->scope = EG(scope); /* ??? */
+ zval *var_ptr;
- call = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_CODE,
- (zend_function*)new_op_array, 0, EX(called_scope), Z_OBJ(EX(This)), NULL TSRMLS_CC);
+ SAVE_OPLINE();
+ var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- if (EX(symbol_table)) {
- call->symbol_table = EX(symbol_table);
- } else {
- call->symbol_table = zend_rebuild_symbol_table(TSRMLS_C);
- }
+ if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
+ }
- call->prev_execute_data = execute_data;
- i_init_code_execute_data(call, new_op_array, return_value TSRMLS_CC);
- if (EXPECTED(zend_execute_ex == execute_ex)) {
- ZEND_VM_ENTER();
- } else {
- ZEND_ADD_CALL_FLAG(call, ZEND_CALL_TOP);
- zend_execute_ex(call TSRMLS_CC);
+ if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
+ fast_decrement_function(var_ptr);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
}
+ ZEND_VM_NEXT_OPCODE();
+ }
- destroy_op_array(new_op_array TSRMLS_CC);
- efree_size(new_op_array, sizeof(zend_op_array));
- if (UNEXPECTED(EG(exception) != NULL)) {
- zend_throw_exception_internal(NULL TSRMLS_CC);
- HANDLE_EXCEPTION();
+ if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
}
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
- } else if (RETURN_VALUE_USED(opline)) {
- ZVAL_BOOL(EX_VAR(opline->result.var), failure_retval);
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
+
+ decrement_function(var_ptr);
+
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
}
+
+ CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FE_RESET_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_POST_INC_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *array_ptr, *array_ref, iterator, tmp;
- HashTable *fe_ht;
- zend_object_iterator *iter = NULL;
- zend_class_entry *ce = NULL;
- zend_bool is_empty = 0;
+ zval *var_ptr;
SAVE_OPLINE();
+ var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- if ((IS_CV == IS_CV || IS_CV == IS_VAR) &&
- (opline->extended_value & ZEND_FE_FETCH_BYREF)) {
- array_ptr = array_ref = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- ZVAL_DEREF(array_ptr);
- if (Z_TYPE_P(array_ptr) == IS_ARRAY) {
- SEPARATE_ARRAY(array_ptr);
- if (!Z_ISREF_P(array_ref)) {
- ZVAL_NEW_REF(array_ref, array_ref);
- array_ptr = Z_REFVAL_P(array_ref);
- }
- if (Z_REFCOUNTED_P(array_ref)) Z_ADDREF_P(array_ref);
- } else if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
- ce = Z_OBJCE_P(array_ptr);
- if (ce->get_iterator == NULL) {
- Z_ADDREF_P(array_ptr);
- }
- array_ref = array_ptr;
- } else {
- if (Z_REFCOUNTED_P(array_ref)) Z_ADDREF_P(array_ref);
- }
- } else {
- array_ptr = array_ref = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- ZVAL_DEREF(array_ptr);
- if (IS_CV == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&tmp, array_ptr);
- if (Z_OPT_IMMUTABLE_P(&tmp)) {
- zval_copy_ctor_func(&tmp);
- }
- array_ref = array_ptr = &tmp;
- if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
- ce = Z_OBJCE_P(array_ptr);
- if (ce && ce->get_iterator) {
- Z_DELREF_P(array_ref);
- }
- }
- } else if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
- ce = Z_OBJCE_P(array_ptr);
- if (!ce->get_iterator) {
- if (IS_CV == IS_CV) {
- Z_ADDREF_P(array_ref);
- }
- }
- } else if (Z_IMMUTABLE_P(array_ref)) {
- if (IS_CV == IS_CV) {
- zval_copy_ctor_func(array_ref);
- Z_ADDREF_P(array_ref);
- } else {
- ZVAL_COPY_VALUE(&tmp, array_ref);
- zval_copy_ctor_func(&tmp);
- array_ptr = array_ref = &tmp;
- }
- } else if (Z_REFCOUNTED_P(array_ref)) {
- if (IS_CV == IS_CONST ||
- (IS_CV == IS_CV &&
- !Z_ISREF_P(array_ref) &&
- Z_REFCOUNT_P(array_ref) > 1) ||
- (IS_CV == IS_VAR &&
- !Z_ISREF_P(array_ref) &&
- Z_REFCOUNT_P(array_ref) > 2)) {
- if (IS_CV == IS_VAR) {
- Z_DELREF_P(array_ref);
- }
- ZVAL_DUP(&tmp, array_ref);
- array_ptr = array_ref = &tmp;
- } else if (IS_CV == IS_CV || IS_CV == IS_VAR) {
- if (Z_ISREF_P(array_ref) && Z_REFCOUNT_P(array_ref) == 1) {
- ZVAL_UNREF(array_ref);
- array_ptr = array_ref;
- }
- if (Z_IMMUTABLE_P(array_ptr)) {
- zval_copy_ctor_func(array_ptr);
- } else if (Z_ISREF_P(array_ref) &&
- Z_COPYABLE_P(array_ptr) &&
- Z_REFCOUNT_P(array_ptr) > 1) {
- Z_DELREF_P(array_ptr);
- zval_copy_ctor_func(array_ptr);
- }
- if (IS_CV == IS_CV) {
- Z_ADDREF_P(array_ref);
- }
- }
- }
+ if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
}
- if (ce && ce->get_iterator) {
- iter = ce->get_iterator(ce, array_ptr, opline->extended_value & ZEND_FE_FETCH_BYREF TSRMLS_CC);
-
- if (IS_CV == IS_VAR && !(opline->extended_value & ZEND_FE_FETCH_BYREF)) {
-
- }
- if (iter && EXPECTED(EG(exception) == NULL)) {
- ZVAL_OBJ(&iterator, &iter->std);
- array_ptr = array_ref = &iterator;
- } else {
- if (IS_CV == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
+ if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
+ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
+ fast_increment_function(var_ptr);
+ ZEND_VM_NEXT_OPCODE();
+ }
- }
- if (!EG(exception)) {
- zend_throw_exception_ex(NULL, 0 TSRMLS_CC, "Object of type %s did not create an Iterator", ce->name->val);
- }
- zend_throw_exception_internal(NULL TSRMLS_CC);
- HANDLE_EXCEPTION();
- }
+ if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), array_ref);
+ ZVAL_DEREF(var_ptr);
+ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
+ zval_opt_copy_ctor(var_ptr);
- if (iter) {
- iter->index = 0;
- if (iter->funcs->rewind) {
- iter->funcs->rewind(iter TSRMLS_CC);
- if (UNEXPECTED(EG(exception) != NULL)) {
- zval_ptr_dtor(array_ref);
- if (IS_CV == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
+ increment_function(var_ptr);
- }
- HANDLE_EXCEPTION();
- }
- }
- is_empty = iter->funcs->valid(iter TSRMLS_CC) != SUCCESS;
- if (UNEXPECTED(EG(exception) != NULL)) {
- zval_ptr_dtor(array_ref);
- if (IS_CV == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- }
- HANDLE_EXCEPTION();
- }
- iter->index = -1; /* will be set to 0 before using next handler */
- } else if ((fe_ht = HASH_OF(array_ptr)) != NULL) {
- HashPointer *ptr = (HashPointer*)EX_VAR((opline+2)->op1.var);
- HashPosition pos = 0;
- Bucket *p;
+static int ZEND_FASTCALL ZEND_POST_DEC_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- while (1) {
- if (pos >= fe_ht->nNumUsed) {
- is_empty = 1;
- if (IS_CV == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
+ zval *var_ptr;
- }
- ZEND_VM_JMP(opline->op2.jmp_addr);
- }
- p = fe_ht->arData + pos;
- if (Z_TYPE(p->val) == IS_UNDEF ||
- (Z_TYPE(p->val) == IS_INDIRECT &&
- Z_TYPE_P(Z_INDIRECT(p->val)) == IS_UNDEF)) {
- pos++;
- continue;
- }
- if (!ce ||
- !p->key ||
- zend_check_property_access(Z_OBJ_P(array_ptr), p->key TSRMLS_CC) == SUCCESS) {
- break;
- }
- pos++;
- }
- fe_ht->nInternalPointer = pos;
- ptr->pos = pos;
- ptr->ht = fe_ht;
- ptr->h = fe_ht->arData[pos].h;
- ptr->key = fe_ht->arData[pos].key;
- is_empty = 0;
- } else {
- zend_error(E_WARNING, "Invalid argument supplied for foreach()");
- is_empty = 1;
- }
+ SAVE_OPLINE();
+ var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
+ if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
+ }
+ if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
+ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
+ fast_decrement_function(var_ptr);
+ ZEND_VM_NEXT_OPCODE();
}
- if (is_empty) {
- ZEND_VM_JMP(opline->op2.jmp_addr);
- } else {
+
+ if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
+
+ ZVAL_DEREF(var_ptr);
+ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
+ zval_opt_copy_ctor(var_ptr);
+
+ decrement_function(var_ptr);
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_EXIT_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ECHO_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
-#if 0 || (IS_CV != IS_UNUSED)
USE_OPLINE
+ zval *z;
+
SAVE_OPLINE();
- if (IS_CV != IS_UNUSED) {
+ z = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- zval *ptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ zend_print_variable(z TSRMLS_CC);
- if (Z_TYPE_P(ptr) == IS_LONG) {
- EG(exit_status) = Z_LVAL_P(ptr);
- } else {
- zend_print_variable(ptr TSRMLS_CC);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_PRINT_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ ZVAL_LONG(EX_VAR(opline->result.var), 1);
+ return ZEND_ECHO_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL ZEND_JMPZ_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ zval *val;
+
+ SAVE_OPLINE();
+ val = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+
+ if (IS_CV == IS_TMP_VAR) {
+ if (Z_TYPE_P(val) == IS_TRUE) {
+ ZEND_VM_SET_OPCODE(opline + 1);
+ ZEND_VM_CONTINUE();
+ } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+ ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+ ZEND_VM_CONTINUE();
}
+ }
+ if (i_zend_is_true(val TSRMLS_CC)) {
+ opline++;
+ } else {
+ opline = opline->op2.jmp_addr;
}
-#endif
- zend_bailout();
- ZEND_VM_NEXT_OPCODE(); /* Never reached */
+
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ ZEND_VM_JMP(opline);
}
-static int ZEND_FASTCALL ZEND_JMP_SET_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_JMPNZ_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *value;
- int is_ref = 0;
+ zval *val;
SAVE_OPLINE();
- value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ val = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- if ((IS_CV == IS_VAR || IS_CV == IS_CV) && Z_ISREF_P(value)) {
- is_ref = 1;
- value = Z_REFVAL_P(value);
+ if (IS_CV == IS_TMP_VAR) {
+ if (Z_TYPE_P(val) == IS_TRUE) {
+ ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+ ZEND_VM_CONTINUE();
+ } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+ ZEND_VM_SET_OPCODE(opline + 1);
+ ZEND_VM_CONTINUE();
+ }
}
- if (i_zend_is_true(value TSRMLS_CC)) {
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), value);
- if (IS_CV == IS_CONST) {
- if (UNEXPECTED(Z_OPT_COPYABLE_P(value))) {
- zval_copy_ctor_func(EX_VAR(opline->result.var));
- }
- } else if (IS_CV == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
- } else if (IS_CV == IS_VAR && is_ref) {
- if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
- }
- ZEND_VM_JMP(opline->op2.jmp_addr);
+ if (i_zend_is_true(val TSRMLS_CC)) {
+ opline = opline->op2.jmp_addr;
+ } else {
+ opline++;
}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ ZEND_VM_JMP(opline);
}
-static int ZEND_FASTCALL ZEND_COALESCE_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_JMPZNZ_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *value;
- int is_ref = 0;
+ zval *val;
SAVE_OPLINE();
- value = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
+ val = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- if ((IS_CV == IS_VAR || IS_CV == IS_CV) && Z_ISREF_P(value)) {
- is_ref = 1;
- value = Z_REFVAL_P(value);
+ if (IS_CV == IS_TMP_VAR) {
+ if (EXPECTED(Z_TYPE_P(val) == IS_TRUE)) {
+ ZEND_VM_SET_RELATIVE_OPCODE(opline, opline->extended_value);
+ ZEND_VM_CONTINUE();
+ } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+ ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+ ZEND_VM_CONTINUE();
+ }
}
- if (Z_TYPE_P(value) > IS_NULL) {
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), value);
- if (IS_CV == IS_CONST) {
- if (UNEXPECTED(Z_OPT_COPYABLE_P(value))) {
- zval_copy_ctor_func(EX_VAR(opline->result.var));
- }
- } else if (IS_CV == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
- } else if (IS_CV == IS_VAR && is_ref) {
- if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
-
- }
- ZEND_VM_JMP(opline->op2.jmp_addr);
+ if (i_zend_is_true(val TSRMLS_CC)) {
+ opline = (zend_op*)(((char*)opline) + opline->extended_value);
+ } else {
+ opline = opline->op2.jmp_addr;
}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ ZEND_VM_JMP(opline);
}
-static int ZEND_FASTCALL ZEND_QM_ASSIGN_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_JMPZ_EX_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *value;
+ zval *val;
SAVE_OPLINE();
- value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ val = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- if ((IS_CV == IS_VAR || IS_CV == IS_CV) && Z_ISREF_P(value)) {
- ZVAL_COPY(EX_VAR(opline->result.var), Z_REFVAL_P(value));
+ if (IS_CV == IS_TMP_VAR) {
+ if (Z_TYPE_P(val) == IS_TRUE) {
+ ZVAL_TRUE(EX_VAR(opline->result.var));
+ ZEND_VM_SET_OPCODE(opline + 1);
+ ZEND_VM_CONTINUE();
+ } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+ ZVAL_FALSE(EX_VAR(opline->result.var));
+ ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+ ZEND_VM_CONTINUE();
+ }
+ }
+
+ if (i_zend_is_true(val TSRMLS_CC)) {
+ ZVAL_TRUE(EX_VAR(opline->result.var));
+ opline++;
} else {
- ZVAL_COPY_VALUE(EX_VAR(opline->result.var), value);
- if (IS_CV == IS_CONST) {
- if (UNEXPECTED(Z_OPT_COPYABLE_P(value))) {
- zval_copy_ctor_func(EX_VAR(opline->result.var));
- }
- } else if (IS_CV == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
- }
+
+ ZVAL_FALSE(EX_VAR(opline->result.var));
+ opline = opline->op2.jmp_addr;
}
- ZEND_VM_NEXT_OPCODE();
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ ZEND_VM_JMP(opline);
}
-static int ZEND_FASTCALL ZEND_STRLEN_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_JMPNZ_EX_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *value;
+ zval *val;
SAVE_OPLINE();
- value = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- if (EXPECTED(Z_TYPE_P(value) == IS_STRING)) {
- ZVAL_LONG(EX_VAR(opline->result.var), Z_STRLEN_P(value));
- } else {
- if (Z_TYPE_P(value) < IS_TRUE) {
- ZVAL_LONG(EX_VAR(opline->result.var), 0);
- } else if (Z_TYPE_P(value) == IS_TRUE) {
- ZVAL_LONG(EX_VAR(opline->result.var), 1);
- } else if (Z_TYPE_P(value) <= IS_DOUBLE) {
- zend_string *str = zval_get_string(value);
- ZVAL_LONG(EX_VAR(opline->result.var), str->len);
- zend_string_release(str);
- } else if (Z_TYPE_P(value) == IS_OBJECT) {
- zend_string *str;
- zval tmp;
+ val = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- ZVAL_COPY(&tmp, value);
- if (parse_arg_object_to_str(&tmp, &str, IS_STRING TSRMLS_CC) == FAILURE) {
- goto strlen_error;
- }
- ZVAL_LONG(EX_VAR(opline->result.var), str->len);
- zval_dtor(&tmp);
- } else {
-strlen_error:
- zend_error(E_WARNING, "strlen() expects parameter 1 to be string, %s given", zend_get_type_by_const(Z_TYPE_P(value)));
- ZVAL_NULL(EX_VAR(opline->result.var));
+ if (IS_CV == IS_TMP_VAR) {
+ if (Z_TYPE_P(val) == IS_TRUE) {
+ ZVAL_TRUE(EX_VAR(opline->result.var));
+ ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+ ZEND_VM_CONTINUE();
+ } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+ ZVAL_FALSE(EX_VAR(opline->result.var));
+ ZEND_VM_SET_OPCODE(opline + 1);
+ ZEND_VM_CONTINUE();
}
}
+ if (i_zend_is_true(val TSRMLS_CC)) {
+ ZVAL_TRUE(EX_VAR(opline->result.var));
+ opline = opline->op2.jmp_addr;
+ } else {
+ ZVAL_FALSE(EX_VAR(opline->result.var));
+ opline++;
+ }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ ZEND_VM_JMP(opline);
}
-static int ZEND_FASTCALL ZEND_TYPE_CHECK_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_RETURN_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *value;
+ zval *retval_ptr;
SAVE_OPLINE();
- value = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- switch (opline->extended_value) {
- case IS_NULL:
- case IS_LONG:
- case IS_DOUBLE:
- case IS_STRING:
- case IS_ARRAY:
- ZVAL_BOOL(EX_VAR(opline->result.var), Z_TYPE_P(value) == opline->extended_value);
- break;
- case _IS_BOOL:
- ZVAL_BOOL(EX_VAR(opline->result.var), Z_TYPE_P(value) == IS_TRUE || Z_TYPE_P(value) == IS_FALSE);
- break;
- case IS_OBJECT:
- if (Z_TYPE_P(value) == opline->extended_value) {
- zend_class_entry *ce = Z_OBJCE_P(value);
- if (ce->name->len == sizeof("__PHP_Incomplete_Class") - 1
- && !strncmp(ce->name->val, "__PHP_Incomplete_Class", ce->name->len)) {
- ZVAL_FALSE(EX_VAR(opline->result.var));
- } else {
- ZVAL_TRUE(EX_VAR(opline->result.var));
+ retval_ptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+
+ if (!EX(return_value)) {
+
+ } else {
+ if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
+ if (IS_CV == IS_CONST) {
+ if (UNEXPECTED(Z_OPT_COPYABLE_P(EX(return_value)))) {
+ zval_copy_ctor_func(EX(return_value));
}
- } else {
- ZVAL_FALSE(EX_VAR(opline->result.var));
}
- break;
- case IS_RESOURCE:
- if (Z_TYPE_P(value) == opline->extended_value) {
- const char *type_name = zend_rsrc_list_get_rsrc_type(Z_RES_P(value) TSRMLS_CC);
- ZVAL_BOOL(EX_VAR(opline->result.var), type_name != NULL);
- } else {
- ZVAL_FALSE(EX_VAR(opline->result.var));
+ } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(retval_ptr)) {
+ ZVAL_COPY(EX(return_value), Z_REFVAL_P(retval_ptr));
+
+ } else {
+ ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
+ if (IS_CV == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(retval_ptr)) Z_ADDREF_P(retval_ptr);
}
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
+ }
}
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_ADD_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_RETURN_BY_REF_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *retval_ptr;
SAVE_OPLINE();
- fast_add_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
+ do {
+ if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR ||
+ (IS_CV == IS_VAR && opline->extended_value == ZEND_RETURNS_VALUE)) {
+ /* Not supposed to happen, but we'll allow it */
+ zend_error(E_NOTICE, "Only variable references should be returned by reference");
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ retval_ptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ if (!EX(return_value)) {
+ if (IS_CV == IS_TMP_VAR) {
-static int ZEND_FASTCALL ZEND_SUB_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ }
+ } else {
+ ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
+ Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
+ if (IS_CV != IS_TMP_VAR) {
+ zval_opt_copy_ctor_no_imm(EX(return_value));
+ }
+ }
+ break;
+ }
+ retval_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- SAVE_OPLINE();
- fast_sub_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
+ if (IS_CV == IS_VAR && UNEXPECTED(retval_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot return string offsets by reference");
+ }
+
+ if (IS_CV == IS_VAR) {
+ if (retval_ptr == &EG(uninitialized_zval) ||
+ (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+ !(Z_VAR_FLAGS_P(retval_ptr) & IS_VAR_RET_REF))) {
+ zend_error(E_NOTICE, "Only variable references should be returned by reference");
+ if (EX(return_value)) {
+ ZVAL_NEW_REF(EX(return_value), retval_ptr);
+ Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
+ if (Z_REFCOUNTED_P(retval_ptr)) Z_ADDREF_P(retval_ptr);
+ }
+ break;
+ }
+ }
+ if (EX(return_value)) {
+ ZVAL_MAKE_REF(retval_ptr);
+ Z_ADDREF_P(retval_ptr);
+ ZVAL_REF(EX(return_value), Z_REF_P(retval_ptr));
+ Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
+ }
+ } while (0);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_MUL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_THROW_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *value;
SAVE_OPLINE();
- fast_mul_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
+ value = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ if (IS_CV == IS_CONST || UNEXPECTED(Z_TYPE_P(value) != IS_OBJECT)) {
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ zend_error_noreturn(E_ERROR, "Can only throw objects");
+ }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ zend_exception_save(TSRMLS_C);
+ if (IS_CV != IS_TMP_VAR) {
+ if (Z_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+ }
+
+ zend_throw_exception_object(value TSRMLS_CC);
+ zend_exception_restore(TSRMLS_C);
+
+ HANDLE_EXCEPTION();
}
-static int ZEND_FASTCALL ZEND_DIV_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SEND_VAR_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *varptr, *arg;
- SAVE_OPLINE();
- fast_div_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
-
+ varptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
+ ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
+ if (Z_ISREF_P(varptr)) {
+ ZVAL_COPY(arg, Z_REFVAL_P(varptr));
- CHECK_EXCEPTION();
+ } else {
+ ZVAL_COPY_VALUE(arg, varptr);
+ if (IS_CV == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(arg)) Z_ADDREF_P(arg);
+ }
+ }
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_MOD_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SEND_VAR_NO_REF_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *varptr, *arg;
SAVE_OPLINE();
- fast_mod_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
-
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-static int ZEND_FASTCALL ZEND_SL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ if (!(opline->extended_value & ZEND_ARG_COMPILE_TIME_BOUND)) {
+ if (!ARG_SHOULD_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
+ return ZEND_SEND_VAR_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+ }
+ varptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ if ((!(opline->extended_value & ZEND_ARG_SEND_FUNCTION) ||
+ (Z_VAR_FLAGS_P(varptr) & IS_VAR_RET_REF)) &&
+ (Z_ISREF_P(varptr) || Z_TYPE_P(varptr) == IS_OBJECT)) {
- SAVE_OPLINE();
- shift_left_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
+ ZVAL_MAKE_REF(varptr);
+ if (IS_CV == IS_CV) {
+ Z_ADDREF_P(varptr);
+ }
+ } else {
+ if ((opline->extended_value & ZEND_ARG_COMPILE_TIME_BOUND) ?
+ !(opline->extended_value & ZEND_ARG_SEND_SILENT) :
+ !ARG_MAY_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
+ zend_error(E_STRICT, "Only variables should be passed by reference");
+ }
+ }
+ arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
+ ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
+ ZVAL_COPY_VALUE(arg, varptr);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_SR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SEND_REF_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *varptr, *arg;
SAVE_OPLINE();
- shift_right_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
+ varptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+
+ if (IS_CV == IS_VAR && UNEXPECTED(varptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Only variables can be passed by reference");
+ }
+ arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
+ ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
+ if (IS_CV == IS_VAR && UNEXPECTED(varptr == &EG(error_zval))) {
+ ZVAL_NEW_REF(arg, &EG(uninitialized_zval));
+ ZEND_VM_NEXT_OPCODE();
+ }
+
+ if (Z_ISREF_P(varptr)) {
+ Z_ADDREF_P(varptr);
+ ZVAL_COPY_VALUE(arg, varptr);
+ } else if (IS_CV == IS_VAR &&
+ UNEXPECTED(Z_TYPE_P(EX_VAR(opline->op1.var)) != IS_INDIRECT)) {
+ ZVAL_NEW_REF(arg, varptr);
+ } else {
+ ZVAL_NEW_REF(arg, varptr);
+ Z_ADDREF_P(arg);
+ ZVAL_REF(varptr, Z_REF_P(arg));
+ }
- CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_CONCAT_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SEND_VAR_EX_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *varptr, *arg;
- SAVE_OPLINE();
- concat_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
-
+ if (ARG_SHOULD_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
+ return ZEND_SEND_REF_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+ varptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
+ ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
+ if (Z_ISREF_P(varptr)) {
+ ZVAL_COPY(arg, Z_REFVAL_P(varptr));
- CHECK_EXCEPTION();
+ } else {
+ ZVAL_COPY_VALUE(arg, varptr);
+ if (IS_CV == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(arg)) Z_ADDREF_P(arg);
+ }
+ }
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_IS_IDENTICAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SEND_USER_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *arg, *param, tmp;
- SAVE_OPLINE();
- fast_is_identical_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
+ arg = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ param = ZEND_CALL_ARG(EX(call), opline->op2.num);
+ if (ARG_SHOULD_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
+ // TODO: Scalar values don't have reference counters anymore.
+ // They are assumed to be 1, and they may be easily passed by
+ // reference now. However, previously scalars with refcount==1
+ // might be passed and with refcount>1 might not. We can support
+ // only single behavior ???
+#if 0
+ if (Z_REFCOUNTED_P(arg) &&
+ // This solution breaks the following test (omit warning message) ???
+ // Zend/tests/bug61273.phpt
+ // ext/reflection/tests/bug42976.phpt
+ // ext/standard/tests/general_functions/call_user_func_array_variation_001.phpt
+#else
+ if (!Z_REFCOUNTED_P(arg) ||
+ // This solution breaks the following test (emit warning message) ???
+ // ext/pdo_sqlite/tests/pdo_005.phpt
+#endif
+ (!Z_ISREF_P(arg) /*&& Z_REFCOUNT_P(arg) > 1???*/)) {
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ if (!ARG_MAY_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
-static int ZEND_FASTCALL ZEND_IS_NOT_IDENTICAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ zend_error(E_WARNING, "Parameter %d to %s%s%s() expected to be a reference, value given",
+ opline->op2.num,
+ EX(call)->func->common.scope ? EX(call)->func->common.scope->name->val : "",
+ EX(call)->func->common.scope ? "::" : "",
+ EX(call)->func->common.function_name->val);
- zval *result = EX_VAR(opline->result.var);
+ if (EX(call)->func->common.fn_flags & ZEND_ACC_CLOSURE) {
+ OBJ_RELEASE((zend_object*)EX(call)->func->common.prototype);
+ }
+ if (Z_OBJ(EX(call)->This)) {
+ OBJ_RELEASE(Z_OBJ(EX(call)->This));
+ }
+ EX(call)->func = (zend_function*)&zend_pass_function;
+ EX(call)->called_scope = NULL;
+ Z_OBJ(EX(call)->This) = NULL;
- SAVE_OPLINE();
- fast_is_not_identical_function(result,
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+
+ if (Z_REFCOUNTED_P(arg)) {
+ Z_DELREF_P(arg);
+ }
+ ZVAL_DUP(&tmp, arg);
+ ZVAL_NEW_REF(arg, &tmp);
+ Z_ADDREF_P(arg);
+ } else if (!Z_ISREF_P(arg)) {
+ ZVAL_NEW_REF(arg, arg);
+ Z_ADDREF_P(arg);
+ } else if (Z_REFCOUNTED_P(arg)) {
+ Z_ADDREF_P(arg);
+ }
+ ZVAL_COPY_VALUE(param, arg);
+ } else if (Z_ISREF_P(arg) &&
+ /* don't separate references for __call */
+ (EX(call)->func->common.fn_flags & ZEND_ACC_CALL_VIA_HANDLER) == 0) {
+ ZVAL_DUP(param, Z_REFVAL_P(arg));
+ } else {
+ ZVAL_COPY(param, arg);
+ }
+ ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_IS_EQUAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BOOL_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *result = EX_VAR(opline->result.var);
+ zval *retval = EX_VAR(opline->result.var);
SAVE_OPLINE();
- fast_equal_function(result,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
-
+ /* PHP 3.0 returned "" for false and 1 for true, here we use 0 and 1 for now */
+ ZVAL_BOOL(retval, i_zend_is_true(_get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC) TSRMLS_CC));
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_IS_NOT_EQUAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_CLONE_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *result = EX_VAR(opline->result.var);
+ zval *obj;
+ zend_class_entry *ce;
+ zend_function *clone;
+ zend_object_clone_obj_t clone_call;
SAVE_OPLINE();
- fast_not_equal_function(result,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
-
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ obj = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-static int ZEND_FASTCALL ZEND_IS_SMALLER_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ if (IS_CV == IS_CONST ||
+ (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(obj) != IS_OBJECT))) {
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ zend_error_noreturn(E_ERROR, "__clone method called on non-object");
+ }
- zval *result = EX_VAR(opline->result.var);
+ ce = Z_OBJCE_P(obj);
+ clone = ce ? ce->clone : NULL;
+ clone_call = Z_OBJ_HT_P(obj)->clone_obj;
+ if (UNEXPECTED(clone_call == NULL)) {
+ if (ce) {
+ zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object of class %s", ce->name->val);
+ } else {
+ zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object");
+ }
+ }
- SAVE_OPLINE();
- fast_is_smaller_function(result,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
+ if (ce && clone) {
+ if (clone->op_array.fn_flags & ZEND_ACC_PRIVATE) {
+ /* Ensure that if we're calling a private function, we're allowed to do so.
+ */
+ if (UNEXPECTED(ce != EG(scope))) {
+ zend_error_noreturn(E_ERROR, "Call to private %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
+ }
+ } else if ((clone->common.fn_flags & ZEND_ACC_PROTECTED)) {
+ /* Ensure that if we're calling a protected function, we're allowed to do so.
+ */
+ if (UNEXPECTED(!zend_check_protected(zend_get_function_root_class(clone), EG(scope)))) {
+ zend_error_noreturn(E_ERROR, "Call to protected %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
+ }
+ }
+ }
+ if (EXPECTED(EG(exception) == NULL)) {
+ ZVAL_OBJ(EX_VAR(opline->result.var), clone_call(obj TSRMLS_CC));
+ if (!RETURN_VALUE_USED(opline) || UNEXPECTED(EG(exception) != NULL)) {
+ OBJ_RELEASE(Z_OBJ_P(EX_VAR(opline->result.var)));
+ }
+ }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_IS_SMALLER_OR_EQUAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_CAST_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *expr;
zval *result = EX_VAR(opline->result.var);
SAVE_OPLINE();
- fast_is_smaller_or_equal_function(result,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
-
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ expr = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-static int ZEND_FASTCALL ZEND_BW_OR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ switch (opline->extended_value) {
+ case IS_NULL:
+ /* This code is taken from convert_to_null. However, it does not seems very useful,
+ * because a conversion to null always results in the same value. This could only
+ * be relevant if a cast_object handler for IS_NULL has some kind of side-effect. */
+#if 0
+ if (IS_CV == IS_VAR || IS_CV == IS_CV) {
+ ZVAL_DEREF(expr);
+ }
+ if (Z_TYPE_P(expr) == IS_OBJECT && Z_OBJ_HT_P(expr)->cast_object) {
+ if (Z_OBJ_HT_P(expr)->cast_object(expr, result, IS_NULL TSRMLS_CC) == SUCCESS) {
+ break;
+ }
+ }
+#endif
+ ZVAL_NULL(result);
+ break;
+ case _IS_BOOL:
+ ZVAL_BOOL(result, zend_is_true(expr TSRMLS_CC));
+ break;
+ case IS_LONG:
+ ZVAL_LONG(result, zval_get_long(expr));
+ break;
+ case IS_DOUBLE:
+ ZVAL_DOUBLE(result, zval_get_double(expr));
+ break;
+ case IS_STRING:
+ ZVAL_STR(result, zval_get_string(expr));
+ break;
+ default:
+ /* If value is already of correct type, return it directly */
+ if (Z_TYPE_P(expr) == opline->extended_value) {
+ ZVAL_COPY_VALUE(result, expr);
+ if (IS_CV == IS_CONST) {
+ if (UNEXPECTED(Z_OPT_COPYABLE_P(result))) {
+ zval_copy_ctor_func(result);
+ }
+ } else if (IS_CV != IS_TMP_VAR) {
+ if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
+ }
- SAVE_OPLINE();
- bitwise_or_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+ if (opline->extended_value == IS_ARRAY) {
+ if (Z_TYPE_P(expr) != IS_OBJECT) {
+ ZVAL_NEW_ARR(result);
+ zend_hash_init(Z_ARRVAL_P(result), 8, NULL, ZVAL_PTR_DTOR, 0);
+ if (Z_TYPE_P(expr) != IS_NULL) {
+ expr = zend_hash_index_add_new(Z_ARRVAL_P(result), 0, expr);
+ if (IS_CV == IS_CONST) {
+ if (UNEXPECTED(Z_OPT_COPYABLE_P(expr))) {
+ zval_copy_ctor_func(expr);
+ }
+ } else {
+ if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
+ }
+ }
+ } else {
+ ZVAL_COPY_VALUE(result, expr);
+ Z_ADDREF_P(result);
+ convert_to_array(result);
+ }
+ } else {
+ if (Z_TYPE_P(expr) != IS_ARRAY) {
+ object_init(result);
+ if (Z_TYPE_P(expr) != IS_NULL) {
+ expr = zend_hash_str_add_new(Z_OBJPROP_P(result), "scalar", sizeof("scalar")-1, expr);
+ if (IS_CV == IS_CONST) {
+ if (UNEXPECTED(Z_OPT_COPYABLE_P(expr))) {
+ zval_copy_ctor_func(expr);
+ }
+ } else {
+ if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
+ }
+ }
+ } else {
+ ZVAL_COPY_VALUE(result, expr);
+ zval_opt_copy_ctor(result);
+ convert_to_object(result);
+ }
+ }
+ }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_BW_AND_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INCLUDE_OR_EVAL_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zend_op_array *new_op_array=NULL;
+ zval *inc_filename;
+ zval tmp_inc_filename;
+ zend_bool failure_retval=0;
SAVE_OPLINE();
- bitwise_and_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
+ inc_filename = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ ZVAL_UNDEF(&tmp_inc_filename);
+ if (Z_TYPE_P(inc_filename) != IS_STRING) {
+ ZVAL_STR(&tmp_inc_filename, zval_get_string(inc_filename));
+ inc_filename = &tmp_inc_filename;
+ }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ if (opline->extended_value != ZEND_EVAL && strlen(Z_STRVAL_P(inc_filename)) != Z_STRLEN_P(inc_filename)) {
+ if (opline->extended_value == ZEND_INCLUDE_ONCE || opline->extended_value == ZEND_INCLUDE) {
+ zend_message_dispatcher(ZMSG_FAILED_INCLUDE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
+ } else {
+ zend_message_dispatcher(ZMSG_FAILED_REQUIRE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
+ }
+ } else {
+ switch (opline->extended_value) {
+ case ZEND_INCLUDE_ONCE:
+ case ZEND_REQUIRE_ONCE: {
+ zend_file_handle file_handle;
+ char *resolved_path;
-static int ZEND_FASTCALL ZEND_BW_XOR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ resolved_path = zend_resolve_path(Z_STRVAL_P(inc_filename), (int)Z_STRLEN_P(inc_filename) TSRMLS_CC);
+ if (resolved_path) {
+ failure_retval = zend_hash_str_exists(&EG(included_files), resolved_path, (int)strlen(resolved_path));
+ } else {
+ resolved_path = Z_STRVAL_P(inc_filename);
+ }
+
+ if (failure_retval) {
+ /* do nothing, file already included */
+ } else if (SUCCESS == zend_stream_open(resolved_path, &file_handle TSRMLS_CC)) {
+ if (!file_handle.opened_path) {
+ file_handle.opened_path = estrdup(resolved_path);
+ }
- SAVE_OPLINE();
- bitwise_xor_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
+ if (zend_hash_str_add_empty_element(&EG(included_files), file_handle.opened_path, (int)strlen(file_handle.opened_path))) {
+ new_op_array = zend_compile_file(&file_handle, (opline->extended_value==ZEND_INCLUDE_ONCE?ZEND_INCLUDE:ZEND_REQUIRE) TSRMLS_CC);
+ zend_destroy_file_handle(&file_handle TSRMLS_CC);
+ } else {
+ zend_file_handle_dtor(&file_handle TSRMLS_CC);
+ failure_retval=1;
+ }
+ } else {
+ if (opline->extended_value == ZEND_INCLUDE_ONCE) {
+ zend_message_dispatcher(ZMSG_FAILED_INCLUDE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
+ } else {
+ zend_message_dispatcher(ZMSG_FAILED_REQUIRE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
+ }
+ }
+ if (resolved_path != Z_STRVAL_P(inc_filename)) {
+ efree(resolved_path);
+ }
+ }
+ break;
+ case ZEND_INCLUDE:
+ case ZEND_REQUIRE:
+ new_op_array = compile_filename(opline->extended_value, inc_filename TSRMLS_CC);
+ break;
+ case ZEND_EVAL: {
+ char *eval_desc = zend_make_compiled_string_description("eval()'d code" TSRMLS_CC);
+ new_op_array = zend_compile_string(inc_filename, eval_desc TSRMLS_CC);
+ efree(eval_desc);
+ }
+ break;
+ EMPTY_SWITCH_DEFAULT_CASE()
+ }
+ }
+ if (Z_TYPE(tmp_inc_filename) != IS_UNDEF) {
+ zend_string_release(Z_STR(tmp_inc_filename));
+ }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ } else if (EXPECTED(new_op_array != NULL)) {
+ zval *return_value = NULL;
+ zend_execute_data *call;
-static int ZEND_FASTCALL ZEND_BOOL_XOR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ if (RETURN_VALUE_USED(opline)) {
+ return_value = EX_VAR(opline->result.var);
+ }
+ new_op_array->scope = EG(scope); /* ??? */
- SAVE_OPLINE();
- boolean_xor_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
+ call = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_CODE,
+ (zend_function*)new_op_array, 0, EX(called_scope), Z_OBJ(EX(This)), NULL TSRMLS_CC);
+ if (EX(symbol_table)) {
+ call->symbol_table = EX(symbol_table);
+ } else {
+ call->symbol_table = zend_rebuild_symbol_table(TSRMLS_C);
+ }
- CHECK_EXCEPTION();
+ call->prev_execute_data = execute_data;
+ i_init_code_execute_data(call, new_op_array, return_value TSRMLS_CC);
+ if (EXPECTED(zend_execute_ex == execute_ex)) {
+ ZEND_VM_ENTER();
+ } else {
+ ZEND_ADD_CALL_FLAG(call, ZEND_CALL_TOP);
+ zend_execute_ex(call TSRMLS_CC);
+ }
+
+ destroy_op_array(new_op_array TSRMLS_CC);
+ efree_size(new_op_array, sizeof(zend_op_array));
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ zend_throw_exception_internal(NULL TSRMLS_CC);
+ HANDLE_EXCEPTION();
+ }
+
+ } else if (RETURN_VALUE_USED(opline)) {
+ ZVAL_BOOL(EX_VAR(opline->result.var), failure_retval);
+ }
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FE_RESET_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op_data1;
- zval *object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- zval *property = opline->op2.zv;
- zval *value;
- zval *zptr;
- if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
+ zval *array_ptr, *array_ref, iterator, tmp;
+ HashTable *fe_ht;
+ zend_object_iterator *iter = NULL;
+ zend_class_entry *ce = NULL;
+ zend_bool is_empty = 0;
- if (IS_CV != IS_UNUSED) {
- object = make_real_object(object TSRMLS_CC);
+ SAVE_OPLINE();
+
+ if ((IS_CV == IS_CV || IS_CV == IS_VAR) &&
+ (opline->extended_value & ZEND_FE_FETCH_BYREF)) {
+ array_ptr = array_ref = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ ZVAL_DEREF(array_ptr);
+ if (Z_TYPE_P(array_ptr) == IS_ARRAY) {
+ SEPARATE_ARRAY(array_ptr);
+ if (!Z_ISREF_P(array_ref)) {
+ ZVAL_NEW_REF(array_ref, array_ref);
+ array_ptr = Z_REFVAL_P(array_ref);
+ }
+ if (Z_REFCOUNTED_P(array_ref)) Z_ADDREF_P(array_ref);
+ } else if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
+ ce = Z_OBJCE_P(array_ptr);
+ if (ce->get_iterator == NULL) {
+ Z_ADDREF_P(array_ptr);
+ }
+ array_ref = array_ptr;
+ } else {
+ if (Z_REFCOUNTED_P(array_ref)) Z_ADDREF_P(array_ref);
+ }
+ } else {
+ array_ptr = array_ref = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ ZVAL_DEREF(array_ptr);
+ if (IS_CV == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&tmp, array_ptr);
+ if (Z_OPT_IMMUTABLE_P(&tmp)) {
+ zval_copy_ctor_func(&tmp);
+ }
+ array_ref = array_ptr = &tmp;
+ if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
+ ce = Z_OBJCE_P(array_ptr);
+ if (ce && ce->get_iterator) {
+ Z_DELREF_P(array_ref);
+ }
+ }
+ } else if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
+ ce = Z_OBJCE_P(array_ptr);
+ if (!ce->get_iterator) {
+ if (IS_CV == IS_CV) {
+ Z_ADDREF_P(array_ref);
+ }
+ }
+ } else if (Z_IMMUTABLE_P(array_ref)) {
+ if (IS_CV == IS_CV) {
+ zval_copy_ctor_func(array_ref);
+ Z_ADDREF_P(array_ref);
+ } else {
+ ZVAL_COPY_VALUE(&tmp, array_ref);
+ zval_copy_ctor_func(&tmp);
+ array_ptr = array_ref = &tmp;
+ }
+ } else if (Z_REFCOUNTED_P(array_ref)) {
+ if (IS_CV == IS_CONST ||
+ (IS_CV == IS_CV &&
+ !Z_ISREF_P(array_ref) &&
+ Z_REFCOUNT_P(array_ref) > 1) ||
+ (IS_CV == IS_VAR &&
+ !Z_ISREF_P(array_ref) &&
+ Z_REFCOUNT_P(array_ref) > 2)) {
+ if (IS_CV == IS_VAR) {
+ Z_DELREF_P(array_ref);
+ }
+ ZVAL_DUP(&tmp, array_ref);
+ array_ptr = array_ref = &tmp;
+ } else if (IS_CV == IS_CV || IS_CV == IS_VAR) {
+ if (Z_ISREF_P(array_ref) && Z_REFCOUNT_P(array_ref) == 1) {
+ ZVAL_UNREF(array_ref);
+ array_ptr = array_ref;
+ }
+ if (Z_IMMUTABLE_P(array_ptr)) {
+ zval_copy_ctor_func(array_ptr);
+ } else if (Z_ISREF_P(array_ref) &&
+ Z_COPYABLE_P(array_ptr) &&
+ Z_REFCOUNT_P(array_ptr) > 1) {
+ Z_DELREF_P(array_ptr);
+ zval_copy_ctor_func(array_ptr);
+ }
+ if (IS_CV == IS_CV) {
+ Z_ADDREF_P(array_ref);
+ }
+ }
+ }
}
- value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+ if (ce && ce->get_iterator) {
+ iter = ce->get_iterator(ce, array_ptr, opline->extended_value & ZEND_FE_FETCH_BYREF TSRMLS_CC);
- if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to assign property of non-object");
+ if (IS_CV == IS_VAR && !(opline->extended_value & ZEND_FE_FETCH_BYREF)) {
- FREE_OP(free_op_data1);
+ }
+ if (iter && EXPECTED(EG(exception) == NULL)) {
+ ZVAL_OBJ(&iterator, &iter->std);
+ array_ptr = array_ref = &iterator;
+ } else {
+ if (IS_CV == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ if (!EG(exception)) {
+ zend_throw_exception_ex(NULL, 0 TSRMLS_CC, "Object of type %s did not create an Iterator", ce->name->val);
+ }
+ zend_throw_exception_internal(NULL TSRMLS_CC);
+ HANDLE_EXCEPTION();
}
- } else {
- /* here we are sure we are dealing with an object */
- if (opline->extended_value == ZEND_ASSIGN_OBJ
- && EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+ }
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
+ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), array_ref);
- binary_op(zptr, zptr, value TSRMLS_CC);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), zptr);
- }
- } else {
- zval *z = NULL;
- zval rv;
+ if (iter) {
+ iter->index = 0;
+ if (iter->funcs->rewind) {
+ iter->funcs->rewind(iter TSRMLS_CC);
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ zval_ptr_dtor(array_ref);
+ if (IS_CV == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
- if (opline->extended_value == ZEND_ASSIGN_OBJ) {
- if (Z_OBJ_HT_P(object)->read_property) {
- z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
- }
- } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
- if (Z_OBJ_HT_P(object)->read_dimension) {
- z = Z_OBJ_HT_P(object)->read_dimension(object, property, BP_VAR_R, &rv TSRMLS_CC);
}
+ HANDLE_EXCEPTION();
}
- if (z) {
- if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
- zval rv;
- zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+ }
+ is_empty = iter->funcs->valid(iter TSRMLS_CC) != SUCCESS;
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ zval_ptr_dtor(array_ref);
+ if (IS_CV == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
+
+ }
+ HANDLE_EXCEPTION();
+ }
+ iter->index = -1; /* will be set to 0 before using next handler */
+ } else if ((fe_ht = HASH_OF(array_ptr)) != NULL) {
+ HashPointer *ptr = (HashPointer*)EX_VAR((opline+2)->op1.var);
+ HashPosition pos = 0;
+ Bucket *p;
+
+ while (1) {
+ if (pos >= fe_ht->nNumUsed) {
+ is_empty = 1;
+ if (IS_CV == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
- if (Z_REFCOUNT_P(z) == 0) {
- zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
- }
- ZVAL_COPY_VALUE(z, value);
- }
-//??? if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
- SEPARATE_ZVAL_IF_NOT_REF(z);
- binary_op(z, z, value TSRMLS_CC);
- if (opline->extended_value == ZEND_ASSIGN_OBJ) {
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
- } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
- Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
- }
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), z);
- }
- zval_ptr_dtor(z);
- } else {
- zend_error(E_WARNING, "Attempt to assign property of non-object");
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
}
+ ZEND_VM_JMP(opline->op2.jmp_addr);
+ }
+ p = fe_ht->arData + pos;
+ if (Z_TYPE(p->val) == IS_UNDEF ||
+ (Z_TYPE(p->val) == IS_INDIRECT &&
+ Z_TYPE_P(Z_INDIRECT(p->val)) == IS_UNDEF)) {
+ pos++;
+ continue;
+ }
+ if (!ce ||
+ !p->key ||
+ zend_check_property_access(Z_OBJ_P(array_ptr), p->key TSRMLS_CC) == SUCCESS) {
+ break;
}
+ pos++;
}
-
- FREE_OP(free_op_data1);
+ fe_ht->nInternalPointer = pos;
+ ptr->pos = pos;
+ ptr->ht = fe_ht;
+ ptr->h = fe_ht->arData[pos].h;
+ ptr->key = fe_ht->arData[pos].key;
+ is_empty = 0;
+ } else {
+ zend_error(E_WARNING, "Invalid argument supplied for foreach()");
+ is_empty = 1;
}
- /* assign_obj has two opcodes! */
- CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
+ if (IS_CV == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
+
+ }
+ if (is_empty) {
+ ZEND_VM_JMP(opline->op2.jmp_addr);
+ } else {
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
}
-static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_CV_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_EXIT_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+#if 0 || (IS_CV != IS_UNUSED)
USE_OPLINE
- zend_free_op free_op_data1;
- zval *var_ptr, rv;
- zval *value, *container;
SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
if (IS_CV != IS_UNUSED) {
- ZVAL_DEREF(container);
- }
- if (IS_CV == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (IS_CV == IS_VAR && !0) {
- Z_ADDREF_P(container); /* undo the effect of get_obj_zval_ptr_ptr() */
- }
- return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else {
- zval *dim = opline->op2.zv;
-
- zend_fetch_dimension_address_RW(&rv, container, dim, IS_CONST TSRMLS_CC);
- value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
- var_ptr = Z_INDIRECT(rv);
- }
- if (UNEXPECTED(var_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
- }
+ zval *ptr = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- if (UNEXPECTED(var_ptr == &EG(error_zval))) {
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_NULL(EX_VAR(opline->result.var));
+ if (Z_TYPE_P(ptr) == IS_LONG) {
+ EG(exit_status) = Z_LVAL_P(ptr);
+ } else {
+ zend_print_variable(ptr TSRMLS_CC);
}
- } else {
- ZVAL_DEREF(var_ptr);
- SEPARATE_ZVAL_NOREF(var_ptr);
-
- binary_op(var_ptr, var_ptr, value TSRMLS_CC);
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
- }
}
-
- FREE_OP(free_op_data1);
-
- CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
+#endif
+ zend_bailout();
+ ZEND_VM_NEXT_OPCODE(); /* Never reached */
}
-static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_JMP_SET_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *var_ptr;
zval *value;
+ int is_ref = 0;
SAVE_OPLINE();
- value = opline->op2.zv;
- var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+ value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
+ if ((IS_CV == IS_VAR || IS_CV == IS_CV) && Z_ISREF_P(value)) {
+ is_ref = 1;
+ value = Z_REFVAL_P(value);
}
+ if (i_zend_is_true(value TSRMLS_CC)) {
+ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), value);
+ if (IS_CV == IS_CONST) {
+ if (UNEXPECTED(Z_OPT_COPYABLE_P(value))) {
+ zval_copy_ctor_func(EX_VAR(opline->result.var));
+ }
+ } else if (IS_CV == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+ } else if (IS_CV == IS_VAR && is_ref) {
+ if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
- if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- } else {
- ZVAL_DEREF(var_ptr);
- SEPARATE_ZVAL_NOREF(var_ptr);
-
- binary_op(var_ptr, var_ptr, value TSRMLS_CC);
-
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
}
+ ZEND_VM_JMP(opline->op2.jmp_addr);
}
-
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_COALESCE_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
+ zval *value;
+ int is_ref = 0;
-static int ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ SAVE_OPLINE();
+ value = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ if ((IS_CV == IS_VAR || IS_CV == IS_CV) && Z_ISREF_P(value)) {
+ is_ref = 1;
+ value = Z_REFVAL_P(value);
}
-}
-static int ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ if (Z_TYPE_P(value) > IS_NULL) {
+ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), value);
+ if (IS_CV == IS_CONST) {
+ if (UNEXPECTED(Z_OPT_COPYABLE_P(value))) {
+ zval_copy_ctor_func(EX_VAR(opline->result.var));
+ }
+ } else if (IS_CV == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+ } else if (IS_CV == IS_VAR && is_ref) {
+ if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+ ZEND_VM_JMP(opline->op2.jmp_addr);
}
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_QM_ASSIGN_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
+ zval *value;
-static int ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ SAVE_OPLINE();
+ value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ if ((IS_CV == IS_VAR || IS_CV == IS_CV) && Z_ISREF_P(value)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), Z_REFVAL_P(value));
+
+ } else {
+ ZVAL_COPY_VALUE(EX_VAR(opline->result.var), value);
+ if (IS_CV == IS_CONST) {
+ if (UNEXPECTED(Z_OPT_COPYABLE_P(value))) {
+ zval_copy_ctor_func(EX_VAR(opline->result.var));
+ }
+ } else if (IS_CV == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+ }
}
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_STRLEN_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *value;
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-static int ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ SAVE_OPLINE();
+ value = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ if (EXPECTED(Z_TYPE_P(value) == IS_STRING)) {
+ ZVAL_LONG(EX_VAR(opline->result.var), Z_STRLEN_P(value));
+ } else {
+ if (Z_TYPE_P(value) < IS_TRUE) {
+ ZVAL_LONG(EX_VAR(opline->result.var), 0);
+ } else if (Z_TYPE_P(value) == IS_TRUE) {
+ ZVAL_LONG(EX_VAR(opline->result.var), 1);
+ } else if (Z_TYPE_P(value) <= IS_DOUBLE) {
+ zend_string *str = zval_get_string(value);
+ ZVAL_LONG(EX_VAR(opline->result.var), str->len);
+ zend_string_release(str);
+ } else if (Z_TYPE_P(value) == IS_OBJECT) {
+ zend_string *str;
+ zval tmp;
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZVAL_COPY(&tmp, value);
+ if (parse_arg_object_to_str(&tmp, &str, IS_STRING TSRMLS_CC) == FAILURE) {
+ goto strlen_error;
+ }
+ ZVAL_LONG(EX_VAR(opline->result.var), str->len);
+ zval_dtor(&tmp);
+ } else {
+strlen_error:
+ zend_error(E_WARNING, "strlen() expects parameter 1 to be string, %s given", zend_get_type_by_const(Z_TYPE_P(value)));
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
}
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_TYPE_CHECK_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *value;
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+
+ SAVE_OPLINE();
+ value = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ switch (opline->extended_value) {
+ case IS_NULL:
+ case IS_LONG:
+ case IS_DOUBLE:
+ case IS_STRING:
+ case IS_ARRAY:
+ ZVAL_BOOL(EX_VAR(opline->result.var), Z_TYPE_P(value) == opline->extended_value);
+ break;
+ case _IS_BOOL:
+ ZVAL_BOOL(EX_VAR(opline->result.var), Z_TYPE_P(value) == IS_TRUE || Z_TYPE_P(value) == IS_FALSE);
+ break;
+ case IS_OBJECT:
+ if (Z_TYPE_P(value) == opline->extended_value) {
+ zend_class_entry *ce = Z_OBJCE_P(value);
+ if (ce->name->len == sizeof("__PHP_Incomplete_Class") - 1
+ && !strncmp(ce->name->val, "__PHP_Incomplete_Class", ce->name->len)) {
+ ZVAL_FALSE(EX_VAR(opline->result.var));
+ } else {
+ ZVAL_TRUE(EX_VAR(opline->result.var));
+ }
+ } else {
+ ZVAL_FALSE(EX_VAR(opline->result.var));
+ }
+ break;
+ case IS_RESOURCE:
+ if (Z_TYPE_P(value) == opline->extended_value) {
+ const char *type_name = zend_rsrc_list_get_rsrc_type(Z_RES_P(value) TSRMLS_CC);
+ ZVAL_BOOL(EX_VAR(opline->result.var), type_name != NULL);
+ } else {
+ ZVAL_FALSE(EX_VAR(opline->result.var));
+ }
+ break;
+ EMPTY_SWITCH_DEFAULT_CASE()
}
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ADD_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ SAVE_OPLINE();
+ fast_add_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ opline->op2.zv TSRMLS_CC);
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SUB_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *object;
- zval *property;
- zval *retval;
- zval *zptr;
SAVE_OPLINE();
- object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- property = opline->op2.zv;
- retval = EX_VAR(opline->result.var);
-
- if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
-
- if (IS_CV != IS_UNUSED) {
- object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
- }
+ fast_sub_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ opline->op2.zv TSRMLS_CC);
- if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(retval);
- }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
+static int ZEND_FASTCALL ZEND_MUL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- /* here we are sure we are dealing with an object */
- if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+ SAVE_OPLINE();
+ fast_mul_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ opline->op2.zv TSRMLS_CC);
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
- incdec_op(zptr);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(retval, zptr);
- }
- } else {
- zval rv;
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+static int ZEND_FASTCALL ZEND_DIV_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
- zval rv;
- zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
- if (Z_REFCOUNT_P(z) == 0) {
- zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
- }
- ZVAL_COPY_VALUE(z, value);
- }
- if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
- SEPARATE_ZVAL_IF_NOT_REF(z);
- incdec_op(z);
- ZVAL_COPY_VALUE(retval, z);
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
- SELECTIVE_PZVAL_LOCK(retval, opline);
- zval_ptr_dtor(z);
- } else {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(retval);
- }
- }
- }
+ SAVE_OPLINE();
+ fast_div_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ opline->op2.zv TSRMLS_CC);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_pre_incdec_property_helper_SPEC_CV_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_pre_incdec_property_helper_SPEC_CV_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_MOD_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *object;
- zval *property;
- zval *retval;
- zval *zptr;
SAVE_OPLINE();
- object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- property = opline->op2.zv;
- retval = EX_VAR(opline->result.var);
-
- if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
-
- if (IS_CV != IS_UNUSED) {
- object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
- }
-
- if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ fast_mod_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ opline->op2.zv TSRMLS_CC);
- ZVAL_NULL(retval);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- /* here we are sure we are dealing with an object */
+static int ZEND_FASTCALL ZEND_SL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
- ZVAL_DEREF(zptr);
- ZVAL_COPY_VALUE(retval, zptr);
- zval_opt_copy_ctor(zptr);
+ SAVE_OPLINE();
+ shift_left_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ opline->op2.zv TSRMLS_CC);
- incdec_op(zptr);
- } else {
- if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval rv;
- zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
- zval z_copy;
- if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
- zval rv;
- zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- if (Z_REFCOUNT_P(z) == 0) {
- zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
- }
- ZVAL_COPY_VALUE(z, value);
- }
- ZVAL_DUP(retval, z);
- ZVAL_DUP(&z_copy, z);
- incdec_op(&z_copy);
- if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
- Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
- zval_ptr_dtor(&z_copy);
- zval_ptr_dtor(z);
- } else {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- ZVAL_NULL(retval);
- }
- }
+static int ZEND_FASTCALL ZEND_SR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+
+ SAVE_OPLINE();
+ shift_right_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ opline->op2.zv TSRMLS_CC);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_CONCAT_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_post_incdec_property_helper_SPEC_CV_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ USE_OPLINE
-static int ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_post_incdec_property_helper_SPEC_CV_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+
+ SAVE_OPLINE();
+ concat_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ opline->op2.zv TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CV_CONST(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_IS_IDENTICAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *varname;
- zval *retval;
- zend_string *name;
- HashTable *target_symbol_table;
SAVE_OPLINE();
- varname = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-
- if (IS_CV == IS_CONST) {
- name = Z_STR_P(varname);
- } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
- name = Z_STR_P(varname);
- zend_string_addref(name);
- } else {
- name = zval_get_string(varname);
- }
+ fast_is_identical_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ opline->op2.zv TSRMLS_CC);
- if (IS_CONST != IS_UNUSED) {
- zend_class_entry *ce;
- if (IS_CONST == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- if (IS_CV != IS_CONST) {
- zend_string_release(name);
- }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
- }
- retval = zend_std_get_static_property(ce, name, 0, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+static int ZEND_FASTCALL ZEND_IS_NOT_IDENTICAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- } else {
- target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- retval = zend_hash_find(target_symbol_table, name);
- if (retval == NULL) {
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_UNSET:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_IS:
- retval = &EG(uninitialized_zval);
- break;
- case BP_VAR_RW:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_W:
- retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
- }
- /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
- } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
- retval = Z_INDIRECT_P(retval);
- if (Z_TYPE_P(retval) == IS_UNDEF) {
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_UNSET:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_IS:
- retval = &EG(uninitialized_zval);
- break;
- case BP_VAR_RW:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_W:
- ZVAL_NULL(retval);
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
- }
- }
- }
- if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
- if (Z_CONSTANT_P(retval)) {
- zval_update_constant(retval, 1 TSRMLS_CC);
- }
- } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
+ zval *result = EX_VAR(opline->result.var);
- }
- }
+ SAVE_OPLINE();
+ fast_is_not_identical_function(result,
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ opline->op2.zv TSRMLS_CC);
- if (IS_CV != IS_CONST) {
- zend_string_release(name);
- }
- ZEND_ASSERT(retval != NULL);
- if (type == BP_VAR_R || type == BP_VAR_IS) {
- if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
- ZVAL_UNREF(retval);
- }
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- } else {
- ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
- }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_R_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_IS_EQUAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ USE_OPLINE
-static int ZEND_FASTCALL ZEND_FETCH_W_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ zval *result = EX_VAR(opline->result.var);
-static int ZEND_FASTCALL ZEND_FETCH_RW_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ SAVE_OPLINE();
+ fast_equal_function(result,
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ opline->op2.zv TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_FUNC_ARG_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_IS_NOT_EQUAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else {
- return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
+ zval *result = EX_VAR(opline->result.var);
+
+ SAVE_OPLINE();
+ fast_not_equal_function(result,
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ opline->op2.zv TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_UNSET_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_IS_SMALLER_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ USE_OPLINE
+
+ zval *result = EX_VAR(opline->result.var);
+
+ SAVE_OPLINE();
+ fast_is_smaller_function(result,
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ opline->op2.zv TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_IS_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_IS_SMALLER_OR_EQUAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ USE_OPLINE
+
+ zval *result = EX_VAR(opline->result.var);
+
+ SAVE_OPLINE();
+ fast_is_smaller_or_equal_function(result,
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ opline->op2.zv TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BW_OR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *container;
SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+ bitwise_or_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ opline->op2.zv TSRMLS_CC);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_W_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BW_AND_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *container;
- SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+ SAVE_OPLINE();
+ bitwise_and_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ opline->op2.zv TSRMLS_CC);
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_RW_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BW_XOR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *container;
- SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+ SAVE_OPLINE();
+ bitwise_xor_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ opline->op2.zv TSRMLS_CC);
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_IS_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BOOL_XOR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *container;
SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
- zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+ boolean_xor_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ opline->op2.zv TSRMLS_CC);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *container;
- zend_free_op free_op1;
+ zend_free_op free_op_data1;
+ zval *object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+ zval *property = opline->op2.zv;
+ zval *value;
+ zval *zptr;
- SAVE_OPLINE();
+ if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+ }
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
- zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
- }
- container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
+ if (IS_CV != IS_UNUSED) {
+ object = make_real_object(object TSRMLS_CC);
+ }
+ value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- } else {
- if (IS_CONST == IS_UNUSED) {
- zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
+ if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ zend_error(E_WARNING, "Attempt to assign property of non-object");
+
+ FREE_OP(free_op_data1);
+
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
}
- container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+ } else {
+ /* here we are sure we are dealing with an object */
+ if (opline->extended_value == ZEND_ASSIGN_OBJ
+ && EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+
+ ZVAL_DEREF(zptr);
+ SEPARATE_ZVAL_NOREF(zptr);
+
+ binary_op(zptr, zptr, value TSRMLS_CC);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), zptr);
+ }
+ } else {
+ zval *z = NULL;
+ zval rv;
+
+ if (opline->extended_value == ZEND_ASSIGN_OBJ) {
+ if (Z_OBJ_HT_P(object)->read_property) {
+ z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+ }
+ } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
+ if (Z_OBJ_HT_P(object)->read_dimension) {
+ z = Z_OBJ_HT_P(object)->read_dimension(object, property, BP_VAR_R, &rv TSRMLS_CC);
+ }
+ }
+ if (z) {
+ if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+ zval rv;
+ zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+ if (Z_REFCOUNT_P(z) == 0) {
+ zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
+ }
+ ZVAL_COPY_VALUE(z, value);
+ }
+//??? if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
+ SEPARATE_ZVAL_IF_NOT_REF(z);
+ binary_op(z, z, value TSRMLS_CC);
+ if (opline->extended_value == ZEND_ASSIGN_OBJ) {
+ Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+ } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
+ Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
+ }
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), z);
+ }
+ zval_ptr_dtor(z);
+ } else {
+ zend_error(E_WARNING, "Attempt to assign property of non-object");
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ }
+ }
+ FREE_OP(free_op_data1);
}
+
+ /* assign_obj has two opcodes! */
CHECK_EXCEPTION();
+ ZEND_VM_INC_OPCODE();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_UNSET_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_CV_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *container;
+ zend_free_op free_op_data1;
+ zval *var_ptr, rv;
+ zval *value, *container;
SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
-
+ container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+ if (IS_CV != IS_UNUSED) {
+ ZVAL_DEREF(container);
+ }
+ if (IS_CV == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ if (IS_CV == IS_VAR && !0) {
+ Z_ADDREF_P(container); /* undo the effect of get_obj_zval_ptr_ptr() */
+ }
+ return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else {
+ zval *dim = opline->op2.zv;
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ zend_fetch_dimension_address_RW(&rv, container, dim, IS_CONST TSRMLS_CC);
+ value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+ ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+ var_ptr = Z_INDIRECT(rv);
}
+ if (UNEXPECTED(var_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
+ }
+
+ if (UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
+
+ binary_op(var_ptr, var_ptr, value TSRMLS_CC);
+
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+ }
+ }
+
+ FREE_OP(free_op_data1);
+
CHECK_EXCEPTION();
+ ZEND_VM_INC_OPCODE();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *container;
-
- zval *offset;
+ zval *var_ptr;
+ zval *value;
SAVE_OPLINE();
- container = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- offset = opline->op2.zv;
-
- if ((IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
- UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
- zend_error(E_NOTICE, "Trying to get property of non-object");
- ZVAL_NULL(EX_VAR(opline->result.var));
- } else {
- zval *retval;
+ value = opline->op2.zv;
+ var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- /* here we are sure we are dealing with an object */
- do {
- if (IS_CONST == IS_CONST &&
- EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
- zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
- zend_object *zobj = Z_OBJ_P(container);
+ if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
+ }
- if (EXPECTED(prop_info)) {
- retval = OBJ_PROP(zobj, prop_info->offset);
- if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- } else if (EXPECTED(zobj->properties != NULL)) {
- retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
- if (EXPECTED(retval)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- }
- }
+ if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+ binary_op(var_ptr, var_ptr, value TSRMLS_CC);
- if (retval != EX_VAR(opline->result.var)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- }
- } while (0);
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+ }
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_W_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
+
+static int ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
+
+static int ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
+
+static int ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
+
+static int ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *property;
- zval *container;
- SAVE_OPLINE();
- property = opline->op2.zv;
-
- container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
+}
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+static int ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_RW_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *property;
- zval *container;
-
- SAVE_OPLINE();
- property = opline->op2.zv;
- container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
-
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *container;
-
- zval *offset;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
- offset = opline->op2.zv;
-
- if ((IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
- UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- } else {
- zval *retval;
-
- /* here we are sure we are dealing with an object */
- do {
- if (IS_CONST == IS_CONST &&
- EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
- zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
- zend_object *zobj = Z_OBJ_P(container);
-
- if (EXPECTED(prop_info)) {
- retval = OBJ_PROP(zobj, prop_info->offset);
- if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- } else if (EXPECTED(zobj->properties != NULL)) {
- retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
- if (EXPECTED(retval)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- }
- }
-
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
-
- if (retval != EX_VAR(opline->result.var)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- }
- } while (0);
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *container;
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- /* Behave like FETCH_OBJ_W */
- zend_free_op free_op1;
- zval *property;
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
- SAVE_OPLINE();
- property = opline->op2.zv;
- container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
- zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
- }
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- } else {
- return ZEND_FETCH_OBJ_R_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_UNSET_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *container, *property;
+
+ zval *object;
+ zval *property;
+ zval *retval;
+ zval *zptr;
SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
+ object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
property = opline->op2.zv;
+ retval = EX_VAR(opline->result.var);
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+ if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
}
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ if (IS_CV != IS_UNUSED) {
+ object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-static int ZEND_FASTCALL ZEND_FETCH_LIST_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(retval);
+ }
- zval *container;
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
- SAVE_OPLINE();
- container = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ /* here we are sure we are dealing with an object */
- if (EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
- zval *value = zend_fetch_dimension_address_inner(Z_ARRVAL_P(container), opline->op2.zv, IS_CONST, BP_VAR_R TSRMLS_CC);
+ ZVAL_DEREF(zptr);
+ SEPARATE_ZVAL_NOREF(zptr);
- ZVAL_COPY(EX_VAR(opline->result.var), value);
- } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT) &&
- EXPECTED(Z_OBJ_HT_P(container)->read_dimension)) {
- zval *result = EX_VAR(opline->result.var);
- zval *retval = Z_OBJ_HT_P(container)->read_dimension(container, opline->op2.zv, BP_VAR_R, result TSRMLS_CC);
+ incdec_op(zptr);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(retval, zptr);
+ }
+ } else {
+ zval rv;
- if (retval) {
- if (result != retval) {
- ZVAL_COPY(result, retval);
+ if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
+ zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+
+ if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
+ zval rv;
+ zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+
+ if (Z_REFCOUNT_P(z) == 0) {
+ zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
+ }
+ ZVAL_COPY_VALUE(z, value);
}
+ if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
+ SEPARATE_ZVAL_IF_NOT_REF(z);
+ incdec_op(z);
+ ZVAL_COPY_VALUE(retval, z);
+ Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+ SELECTIVE_PZVAL_LOCK(retval, opline);
+ zval_ptr_dtor(z);
} else {
- ZVAL_NULL(result);
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(retval);
+ }
}
- } else {
- ZVAL_NULL(EX_VAR(opline->result.var));
}
+
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_pre_incdec_property_helper_SPEC_CV_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_pre_incdec_property_helper_SPEC_CV_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *object;
- zval *property_name;
+ zval *property;
+ zval *retval;
+ zval *zptr;
SAVE_OPLINE();
- object = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- property_name = opline->op2.zv;
+ object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+ property = opline->op2.zv;
+ retval = EX_VAR(opline->result.var);
if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
}
- zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
-
-
- /* assign_obj has two opcodes! */
- CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
-}
-static int ZEND_FASTCALL ZEND_ASSIGN_DIM_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ if (IS_CV != IS_UNUSED) {
+ object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
+ }
- zval *object_ptr;
+ if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- SAVE_OPLINE();
- object_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ ZVAL_NULL(retval);
- if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
- ZVAL_DEREF(object_ptr);
- if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
- zval *property_name = opline->op2.zv;
+ /* here we are sure we are dealing with an object */
- zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
- } else {
- zend_free_op free_op_data1;
- zval rv;
- zval *value;
- zval *dim = opline->op2.zv;
- zval *variable_ptr;
+ ZVAL_DEREF(zptr);
+ ZVAL_COPY_VALUE(retval, zptr);
+ zval_opt_copy_ctor(zptr);
- if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
- EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
- zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
+ incdec_op(zptr);
+ } else {
+ if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
+ zval rv;
+ zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+ zval z_copy;
- value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
- FREE_OP(free_op_data1);
- } else {
- zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_CONST TSRMLS_CC);
+ if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
+ zval rv;
+ zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
- value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
- variable_ptr = Z_INDIRECT(rv);
- if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
- FREE_OP(free_op_data1);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- } else {
- value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
- if ((opline+1)->op1_type == IS_VAR) {
- FREE_OP(free_op_data1);
- }
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), value);
+ if (Z_REFCOUNT_P(z) == 0) {
+ zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
}
+ ZVAL_COPY_VALUE(z, value);
}
+ ZVAL_DUP(retval, z);
+ ZVAL_DUP(&z_copy, z);
+ incdec_op(&z_copy);
+ if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
+ Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+ zval_ptr_dtor(&z_copy);
+ zval_ptr_dtor(z);
+ } else {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ ZVAL_NULL(retval);
}
}
- /* assign_dim has two opcodes! */
+
CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- USE_OPLINE
-
- zval *value;
- zval *variable_ptr;
-
- SAVE_OPLINE();
- value = opline->op2.zv;
- variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-
- if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
- if (IS_CONST == IS_TMP_VAR) {
-
- }
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- } else {
- value = zend_assign_to_variable(variable_ptr, value, IS_CONST TSRMLS_CC);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), value);
- }
-
- }
-
- /* zend_assign_to_variable() always takes care of op2, never free it! */
+ return zend_post_incdec_property_helper_SPEC_CV_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+static int ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_post_incdec_property_helper_SPEC_CV_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CV_CONST(int type, ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *function_name;
- zval *object;
- zend_function *fbc;
- zend_class_entry *called_scope;
- zend_object *obj;
+ zval *varname;
+ zval *retval;
+ zend_string *name;
+ HashTable *target_symbol_table;
SAVE_OPLINE();
+ varname = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- function_name = opline->op2.zv;
-
- if (IS_CONST != IS_CONST &&
- UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- zend_error_noreturn(E_ERROR, "Method name must be a string");
+ if (IS_CV == IS_CONST) {
+ name = Z_STR_P(varname);
+ } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
+ name = Z_STR_P(varname);
+ zend_string_addref(name);
+ } else {
+ name = zval_get_string(varname);
}
- object = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-
- if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- uint32_t nesting = 1;
-
- if (UNEXPECTED(EG(exception) != NULL)) {
-
- HANDLE_EXCEPTION();
- }
-
- zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s", Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
+ if (IS_CONST != IS_UNUSED) {
+ zend_class_entry *ce;
+ if (IS_CONST == IS_CONST) {
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ } else {
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+ if (UNEXPECTED(ce == NULL)) {
+ if (IS_CV != IS_CONST) {
+ zend_string_release(name);
+ }
- if (EG(exception) != NULL) {
- HANDLE_EXCEPTION();
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+ }
+ } else {
+ ce = Z_CE_P(EX_VAR(opline->op2.var));
}
+ retval = zend_std_get_static_property(ce, name, 0, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
- /* No exception raised: Skip over arguments until fcall opcode with correct
- * nesting level. Return NULL (except when return value unused) */
- do {
- opline++;
- if (opline->opcode == ZEND_INIT_FCALL ||
- opline->opcode == ZEND_INIT_FCALL_BY_NAME ||
- opline->opcode == ZEND_INIT_NS_FCALL_BY_NAME ||
- opline->opcode == ZEND_INIT_METHOD_CALL ||
- opline->opcode == ZEND_INIT_STATIC_METHOD_CALL ||
- opline->opcode == ZEND_INIT_USER_CALL ||
- opline->opcode == ZEND_NEW
- ) {
- nesting++;
- } else if (opline->opcode == ZEND_DO_FCALL) {
- nesting--;
+ } else {
+ target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+ retval = zend_hash_find(target_symbol_table, name);
+ if (retval == NULL) {
+ switch (type) {
+ case BP_VAR_R:
+ case BP_VAR_UNSET:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_IS:
+ retval = &EG(uninitialized_zval);
+ break;
+ case BP_VAR_RW:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_W:
+ retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
+ break;
+ EMPTY_SWITCH_DEFAULT_CASE()
+ }
+ /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
+ } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
+ retval = Z_INDIRECT_P(retval);
+ if (Z_TYPE_P(retval) == IS_UNDEF) {
+ switch (type) {
+ case BP_VAR_R:
+ case BP_VAR_UNSET:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_IS:
+ retval = &EG(uninitialized_zval);
+ break;
+ case BP_VAR_RW:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_W:
+ ZVAL_NULL(retval);
+ break;
+ EMPTY_SWITCH_DEFAULT_CASE()
+ }
}
- } while (nesting);
+ }
+ if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
+ if (Z_CONSTANT_P(retval)) {
+ zval_update_constant(retval, 1 TSRMLS_CC);
+ }
+ } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
}
+ }
- /* We've skipped EXT_FCALL_BEGIND, so also skip the ending opcode */
- if ((opline + 1)->opcode == ZEND_EXT_FCALL_END) {
- opline++;
+ if (IS_CV != IS_CONST) {
+ zend_string_release(name);
+ }
+
+ ZEND_ASSERT(retval != NULL);
+ if (type == BP_VAR_R || type == BP_VAR_IS) {
+ if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
+ ZVAL_UNREF(retval);
}
- ZEND_VM_JMP(++opline);
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ } else {
+ ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
}
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- obj = Z_OBJ_P(object);
- called_scope = obj->ce;
+static int ZEND_FASTCALL ZEND_FETCH_R_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
- if (IS_CONST != IS_CONST ||
- EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
- zend_object *orig_obj = obj;
+static int ZEND_FASTCALL ZEND_FETCH_W_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
- if (UNEXPECTED(obj->handlers->get_method == NULL)) {
- zend_error_noreturn(E_ERROR, "Object does not support method calls");
- }
+static int ZEND_FASTCALL ZEND_FETCH_RW_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
- /* First, locate the function. */
- fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_CONST == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
- if (UNEXPECTED(fbc == NULL)) {
- zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
- }
- if (IS_CONST == IS_CONST &&
- EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
- EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
- EXPECTED(obj == orig_obj)) {
- CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope, fbc);
- }
- }
+static int ZEND_FASTCALL ZEND_FETCH_FUNC_ARG_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_STATIC) != 0)) {
- obj = NULL;
+ if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+ return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else {
- GC_REFCOUNT(obj)++; /* For $this pointer */
+ return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
+}
- EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
- fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
-
+static int ZEND_FASTCALL ZEND_FETCH_UNSET_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+static int ZEND_FASTCALL ZEND_FETCH_IS_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_CASE_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *result = EX_VAR(opline->result.var);
+ zval *container;
SAVE_OPLINE();
- fast_equal_function(result,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
+ container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_W_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
- zval *expr_ptr, new_expr;
+ zend_free_op free_op1;
+ zval *container;
SAVE_OPLINE();
- if ((IS_CV == IS_VAR || IS_CV == IS_CV) &&
- (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
- expr_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
- }
- ZVAL_MAKE_REF(expr_ptr);
- Z_ADDREF_P(expr_ptr);
-
- } else {
- expr_ptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&new_expr, expr_ptr);
- expr_ptr = &new_expr;
- } else if (IS_CV == IS_CONST) {
- if (!Z_IMMUTABLE_P(expr_ptr)) {
- ZVAL_DUP(&new_expr, expr_ptr);
- expr_ptr = &new_expr;
- }
- } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(expr_ptr)) {
- expr_ptr = Z_REFVAL_P(expr_ptr);
- if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
+ container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- } else if (IS_CV == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
- Z_ADDREF_P(expr_ptr);
- }
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
- if (IS_CONST != IS_UNUSED) {
-
- zval *offset = opline->op2.zv;
- zend_string *str;
- zend_ulong hval;
-
-add_again:
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- goto num_index;
- case IS_LONG:
- hval = Z_LVAL_P(offset);
-num_index:
- zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
- break;
- case IS_STRING:
- str = Z_STR_P(offset);
- if (IS_CONST != IS_CONST) {
- if (ZEND_HANDLE_NUMERIC(str, hval)) {
- goto num_index;
- }
- }
-str_index:
- zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
- break;
- case IS_NULL:
- str = STR_EMPTY_ALLOC();
- goto str_index;
- case IS_FALSE:
- hval = 0;
- goto num_index;
- case IS_TRUE:
- hval = 1;
- goto num_index;
- case IS_REFERENCE:
- offset = Z_REFVAL_P(offset);
- goto add_again;
- break;
- default:
- zend_error(E_WARNING, "Illegal offset type");
- zval_ptr_dtor(expr_ptr);
- /* do nothing */
- break;
- }
-
- } else {
- zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
+ if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_RW_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- zval *array;
- uint32_t size;
USE_OPLINE
+ zend_free_op free_op1;
+ zval *container;
- array = EX_VAR(opline->result.var);
- if (IS_CV != IS_UNUSED) {
- size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
- } else {
- size = 0;
- }
- ZVAL_NEW_ARR(array);
- zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
+ SAVE_OPLINE();
+ container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV != IS_UNUSED) {
- /* Explicitly initialize array as not-packed if flag is set */
- if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
- zend_hash_real_init(Z_ARRVAL_P(array), 0);
- }
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
- if (IS_CV == IS_UNUSED) {
- ZEND_VM_NEXT_OPCODE();
-#if 0 || IS_CV != IS_UNUSED
- } else {
- return ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-#endif
+ if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_UNSET_VAR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_IS_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval tmp, *varname;
- HashTable *target_symbol_table;
+ zval *container;
SAVE_OPLINE();
- if (IS_CV == IS_CV &&
- IS_CONST == IS_UNUSED &&
- (opline->extended_value & ZEND_QUICK_SET)) {
- zval *var = EX_VAR(opline->op1.var);
+ container = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
+ zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
- if (Z_REFCOUNTED_P(var)) {
- zend_refcounted *garbage = Z_COUNTED_P(var);
- if (!--GC_REFCOUNT(garbage)) {
- ZVAL_UNDEF(var);
- _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
- } else {
- GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
- ZVAL_UNDEF(var);
- }
- } else {
- ZVAL_UNDEF(var);
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- varname = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zval *container;
+ zend_free_op free_op1;
- ZVAL_UNDEF(&tmp);
- if (IS_CV != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
- ZVAL_STR(&tmp, zval_get_string(varname));
- varname = &tmp;
- }
+ SAVE_OPLINE();
- if (IS_CONST != IS_UNUSED) {
- zend_class_entry *ce;
+ if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+ if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
+ zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+ }
+ container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ }
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+ if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ }
- if (IS_CONST == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(EG(exception) != NULL)) {
- if (IS_CV != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
- }
- HANDLE_EXCEPTION();
- }
- if (UNEXPECTED(ce == NULL)) {
- zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
- }
- zend_std_unset_static_property(ce, Z_STR_P(varname), ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
} else {
- target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
- }
+ if (IS_CONST == IS_UNUSED) {
+ zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
+ }
+ container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
- if (IS_CV != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
- }
+ }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_UNSET_DIM_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_UNSET_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
+ zend_free_op free_op1;
zval *container;
- zval *offset;
- zend_ulong hval;
SAVE_OPLINE();
container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
+
if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
- }
- if (IS_CV != IS_UNUSED) {
- ZVAL_DEREF(container);
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
- SEPARATE_ZVAL_NOREF(container);
- offset = opline->op2.zv;
-
- if (IS_CV != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
- HashTable *ht = Z_ARRVAL_P(container);
-offset_again:
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- zend_hash_index_del(ht, hval);
- break;
- case IS_LONG:
- hval = Z_LVAL_P(offset);
-num_index_dim:
- zend_hash_index_del(ht, hval);
- break;
- case IS_STRING:
- if (IS_CONST != IS_CONST) {
- if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
- goto num_index_dim;
- }
- }
- if (ht == &EG(symbol_table).ht) {
- zend_delete_global_variable(Z_STR_P(offset) TSRMLS_CC);
- } else {
- zend_hash_del(ht, Z_STR_P(offset));
- }
- break;
- case IS_NULL:
- zend_hash_del(ht, STR_EMPTY_ALLOC());
- break;
- case IS_FALSE:
- hval = 0;
- goto num_index_dim;
- case IS_TRUE:
- hval = 1;
- goto num_index_dim;
- case IS_RESOURCE:
- hval = Z_RES_HANDLE_P(offset);
- goto num_index_dim;
- case IS_REFERENCE:
- offset = Z_REFVAL_P(offset);
- goto offset_again;
- break;
- default:
- zend_error(E_WARNING, "Illegal offset type in unset");
- break;
- }
-
- } else if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use object as array");
- }
-//??? if (IS_CONST == IS_CONST) {
-//??? zval_copy_ctor(offset);
-//??? }
- Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
-
- } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
- ZEND_VM_CONTINUE(); /* bailed out before */
- } else {
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+ if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_UNSET_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *container;
+
zval *offset;
SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
- }
- offset = opline->op2.zv;
+ container = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ offset = opline->op2.zv;
- if (IS_CV != IS_UNUSED) {
- ZVAL_DEREF(container);
- }
- if (IS_CV == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
- if (Z_OBJ_HT_P(container)->unset_property) {
- Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to unset property of non-object");
- }
+ if ((IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+ UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+ zend_error(E_NOTICE, "Trying to get property of non-object");
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ } else {
+ zval *retval;
+
+ /* here we are sure we are dealing with an object */
+ do {
+ if (IS_CONST == IS_CONST &&
+ EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
+ zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
+ zend_object *zobj = Z_OBJ_P(container);
+
+ if (EXPECTED(prop_info)) {
+ retval = OBJ_PROP(zobj, prop_info->offset);
+ if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
+ }
+ } else if (EXPECTED(zobj->properties != NULL)) {
+ retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
+ if (EXPECTED(retval)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
+ }
+ }
+ }
+
+ retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+
+ if (retval != EX_VAR(opline->result.var)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ }
+ } while (0);
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_VAR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_W_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *value;
+ zend_free_op free_op1;
+ zval *property;
+ zval *container;
SAVE_OPLINE();
- if (IS_CV == IS_CV &&
- IS_CONST == IS_UNUSED &&
- (opline->extended_value & ZEND_QUICK_SET)) {
- value = EX_VAR(opline->op1.var);
- if (opline->extended_value & ZEND_ISSET) {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- !i_zend_is_true(value TSRMLS_CC));
- CHECK_EXCEPTION();
- }
- ZEND_VM_NEXT_OPCODE();
- } else {
-
- zval tmp, *varname = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
+ property = opline->op2.zv;
- ZVAL_UNDEF(&tmp);
- if (IS_CV != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
- ZVAL_STR(&tmp, zval_get_string(varname));
- varname = &tmp;
- }
+ container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+ }
- if (IS_CONST != IS_UNUSED) {
- zend_class_entry *ce;
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
- if (IS_CONST == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
- }
- value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
- } else {
- HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
- }
+ if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ }
- if (IS_CV != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
- }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- if (opline->extended_value & ZEND_ISSET) {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- value && Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- !value || !i_zend_is_true(value TSRMLS_CC));
- }
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_RW_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+ zval *property;
+ zval *container;
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ SAVE_OPLINE();
+ property = opline->op2.zv;
+ container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+ }
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
+
+ if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *container;
- int result;
- zend_ulong hval;
+
zval *offset;
SAVE_OPLINE();
container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
- offset = opline->op2.zv;
+ offset = opline->op2.zv;
- if (IS_CV != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
- HashTable *ht = Z_ARRVAL_P(container);
- zval *value;
- zend_string *str;
+ if ((IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+ UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ } else {
+ zval *retval;
-isset_again:
- if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
- str = Z_STR_P(offset);
- if (IS_CONST != IS_CONST) {
- if (ZEND_HANDLE_NUMERIC(str, hval)) {
- goto num_index_prop;
+ /* here we are sure we are dealing with an object */
+ do {
+ if (IS_CONST == IS_CONST &&
+ EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
+ zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
+ zend_object *zobj = Z_OBJ_P(container);
+
+ if (EXPECTED(prop_info)) {
+ retval = OBJ_PROP(zobj, prop_info->offset);
+ if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
+ }
+ } else if (EXPECTED(zobj->properties != NULL)) {
+ retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
+ if (EXPECTED(retval)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
+ }
}
}
-str_index_prop:
- value = zend_hash_find_ind(ht, str);
- } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
- hval = Z_LVAL_P(offset);
-num_index_prop:
- value = zend_hash_index_find(ht, hval);
- } else {
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- goto num_index_prop;
- case IS_NULL:
- str = STR_EMPTY_ALLOC();
- goto str_index_prop;
- case IS_FALSE:
- hval = 0;
- goto num_index_prop;
- case IS_TRUE:
- hval = 1;
- goto num_index_prop;
- case IS_RESOURCE:
- hval = Z_RES_HANDLE_P(offset);
- goto num_index_prop;
- case IS_REFERENCE:
- offset = Z_REFVAL_P(offset);
- goto isset_again;
- default:
- zend_error(E_WARNING, "Illegal offset type in isset or empty");
- value = NULL;
- break;
- }
- }
- if (opline->extended_value & ZEND_ISSET) {
- /* > IS_NULL means not IS_UNDEF and not IS_NULL */
- result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
- }
- } else if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
- result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to check element of non-array");
- result = 0;
- }
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
- }
- } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
- zval tmp;
+ retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
- result = 0;
- if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
- if (IS_CONST == IS_CV || IS_CONST == IS_VAR) {
- ZVAL_DEREF(offset);
- }
- if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
- || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
- && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
- ZVAL_DUP(&tmp, offset);
- convert_to_long(&tmp);
- offset = &tmp;
- }
- }
- if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
- if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
- if ((opline->extended_value & ZEND_ISSET) ||
- Z_STRVAL_P(container)[offset->value.lval] != '0') {
- result = 1;
- }
+ if (retval != EX_VAR(opline->result.var)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
}
- }
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
- }
- } else {
- result = ((opline->extended_value & ZEND_ISSET) == 0);
+ } while (0);
}
- ZVAL_BOOL(EX_VAR(opline->result.var), result);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
zval *container;
- int result;
- zval *offset;
- SAVE_OPLINE();
- container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
- offset = opline->op2.zv;
+ if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+ /* Behave like FETCH_OBJ_W */
+ zend_free_op free_op1;
+ zval *property;
- if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
- result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to check property of non-object");
- result = 0;
+ SAVE_OPLINE();
+ property = opline->op2.zv;
+ container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+
+ if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
+ zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+ }
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
}
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+
+ if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
} else {
- result = ((opline->extended_value & ZEND_ISSET) == 0);
+ return ZEND_FETCH_OBJ_R_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
+}
- ZVAL_BOOL(EX_VAR(opline->result.var), result);
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_UNSET_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+ zval *container, *property;
+
+ SAVE_OPLINE();
+ container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
+ property = opline->op2.zv;
+
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+ }
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
+
+ if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INSTANCEOF_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_LIST_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *expr;
- zend_bool result;
+ zval *container;
SAVE_OPLINE();
- expr = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ container = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- if (Z_TYPE_P(expr) == IS_OBJECT) {
- zend_class_entry *ce;
+ if (EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
- if (IS_CONST == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, ZEND_FETCH_CLASS_NO_AUTOLOAD TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- ZVAL_FALSE(EX_VAR(opline->result.var));
+ zval *value = zend_fetch_dimension_address_inner(Z_ARRVAL_P(container), opline->op2.zv, IS_CONST, BP_VAR_R TSRMLS_CC);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+ ZVAL_COPY(EX_VAR(opline->result.var), value);
+ } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT) &&
+ EXPECTED(Z_OBJ_HT_P(container)->read_dimension)) {
+ zval *result = EX_VAR(opline->result.var);
+ zval *retval = Z_OBJ_HT_P(container)->read_dimension(container, opline->op2.zv, BP_VAR_R, result TSRMLS_CC);
+
+ if (retval) {
+ if (result != retval) {
+ ZVAL_COPY(result, retval);
}
} else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
+ ZVAL_NULL(result);
}
- result = instanceof_function(Z_OBJCE_P(expr), ce TSRMLS_CC);
} else {
- result = 0;
+ ZVAL_NULL(EX_VAR(opline->result.var));
}
- ZVAL_BOOL(EX_VAR(opline->result.var), result);
-
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_YIELD_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- /* The generator object is stored in EX(return_value) */
- zend_generator *generator = (zend_generator *) EX(return_value);
+ zval *object;
+ zval *property_name;
- if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
- zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
+ SAVE_OPLINE();
+ object = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ property_name = opline->op2.zv;
+
+ if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
+ zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
- /* Destroy the previously yielded value */
- zval_ptr_dtor(&generator->value);
- /* Destroy the previously yielded key */
- zval_ptr_dtor(&generator->key);
+ /* assign_obj has two opcodes! */
+ CHECK_EXCEPTION();
+ ZEND_VM_INC_OPCODE();
+ ZEND_VM_NEXT_OPCODE();
+}
- /* Set the new yielded value */
- if (IS_CV != IS_UNUSED) {
+static int ZEND_FASTCALL ZEND_ASSIGN_DIM_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zval *object_ptr;
- if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
- /* Constants and temporary variables aren't yieldable by reference,
- * but we still allow them with a notice. */
- if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
- zval *value;
+ SAVE_OPLINE();
+ object_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+ if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ }
+ ZVAL_DEREF(object_ptr);
+ if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
- value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- ZVAL_COPY_VALUE(&generator->value, value);
- if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
+ zval *property_name = opline->op2.zv;
- /* Temporary variables don't need ctor copying */
- if (IS_CV != IS_TMP_VAR) {
- zval_opt_copy_ctor(&generator->value);
- }
- } else {
- zval *value_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
- }
+ } else {
+ zend_free_op free_op_data1;
+ zval rv;
+ zval *value;
+ zval *dim = opline->op2.zv;
+ zval *variable_ptr;
- /* If a function call result is yielded and the function did
- * not return by reference we throw a notice. */
- if (IS_CV == IS_VAR &&
- (value_ptr == &EG(uninitialized_zval) ||
- (opline->extended_value == ZEND_RETURNS_FUNCTION &&
- !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
- zend_error(E_NOTICE, "Only variable references should be yielded by reference");
- } else {
- ZVAL_MAKE_REF(value_ptr);
- }
- ZVAL_COPY(&generator->value, value_ptr);
+ if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
+ EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
+ zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
- }
+ value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+ zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
+ FREE_OP(free_op_data1);
} else {
- zval *value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-
- /* Consts, temporary variables and references need copying */
- if (IS_CV == IS_CONST) {
- ZVAL_DUP(&generator->value, value);
- } else if (IS_CV == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&generator->value, value);
- } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(value)) {
- ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
+ zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_CONST TSRMLS_CC);
+ value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+ ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+ variable_ptr = Z_INDIRECT(rv);
+ if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
+ FREE_OP(free_op_data1);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
} else {
- ZVAL_COPY_VALUE(&generator->value, value);
- if (IS_CV == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+ value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
+ if ((opline+1)->op1_type == IS_VAR) {
+ FREE_OP(free_op_data1);
+ }
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), value);
}
}
}
- } else {
- /* If no value was specified yield null */
- ZVAL_NULL(&generator->value);
}
- /* Set the new yielded key */
- if (IS_CONST != IS_UNUSED) {
+ /* assign_dim has two opcodes! */
+ CHECK_EXCEPTION();
+ ZEND_VM_INC_OPCODE();
+ ZEND_VM_NEXT_OPCODE();
+}
- zval *key = opline->op2.zv;
+static int ZEND_FASTCALL ZEND_ASSIGN_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- /* Consts, temporary variables and references need copying */
- if (IS_CONST == IS_CONST) {
- ZVAL_DUP(&generator->key, key);
- } else if (IS_CONST == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&generator->key, key);
- } else if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) && Z_ISREF_P(key)) {
- ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
+ zval *value;
+ zval *variable_ptr;
- } else {
- ZVAL_COPY_VALUE(&generator->key, key);
- if (IS_CONST == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
- }
- }
+ SAVE_OPLINE();
+ value = opline->op2.zv;
+ variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- if (Z_TYPE(generator->key) == IS_LONG
- && Z_LVAL(generator->key) > generator->largest_used_integer_key
- ) {
- generator->largest_used_integer_key = Z_LVAL(generator->key);
+ if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
+ if (IS_CONST == IS_TMP_VAR) {
+
+ }
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
}
} else {
- /* If no key was specified we use auto-increment keys */
- generator->largest_used_integer_key++;
- ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
- }
+ value = zend_assign_to_variable(variable_ptr, value, IS_CONST TSRMLS_CC);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), value);
+ }
- if (RETURN_VALUE_USED(opline)) {
- /* If the return value of yield is used set the send
- * target and initialize it to NULL */
- generator->send_target = EX_VAR(opline->result.var);
- ZVAL_NULL(generator->send_target);
- } else {
- generator->send_target = NULL;
}
- /* We increment to the next op, so we are at the correct position when the
- * generator is resumed. */
- ZEND_VM_INC_OPCODE();
-
- /* The GOTO VM uses a local opline variable. We need to set the opline
- * variable in execute_data so we don't resume at an old position. */
- SAVE_OPLINE();
+ /* zend_assign_to_variable() always takes care of op2, never free it! */
- ZEND_VM_RETURN();
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_POW_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *function_name;
+ zval *object;
+ zend_function *fbc;
+ zend_class_entry *called_scope;
+ zend_object *obj;
SAVE_OPLINE();
- pow_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- opline->op2.zv TSRMLS_CC);
+ function_name = opline->op2.zv;
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ if (IS_CONST != IS_CONST &&
+ UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ zend_error_noreturn(E_ERROR, "Method name must be a string");
+ }
-static int ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_binary_assign_op_helper_SPEC_CV_CONST(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ object = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-static int ZEND_FASTCALL ZEND_BIND_GLOBAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ uint32_t nesting = 1;
- zval *varname;
- zval *value;
- zval *variable_ptr;
- uint32_t idx;
+ if (UNEXPECTED(EG(exception) != NULL)) {
- SAVE_OPLINE();
- varname = opline->op2.zv;
+ HANDLE_EXCEPTION();
+ }
- /* We store "hash slot index" + 1 (NULL is a mark of uninitialized cache slot) */
- idx = (uint32_t)(uintptr_t)CACHED_PTR(Z_CACHE_SLOT_P(varname)) - 1;
- if (EXPECTED(idx < EG(symbol_table).ht.nNumUsed)) {
- Bucket *p = EG(symbol_table).ht.arData + idx;
+ zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s", Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
- if (EXPECTED(Z_TYPE(p->val) != IS_UNDEF) &&
- (EXPECTED(p->key == Z_STR_P(varname)) ||
- (EXPECTED(p->h == Z_STR_P(varname)->h) &&
- EXPECTED(p->key != NULL) &&
- EXPECTED(p->key->len == Z_STRLEN_P(varname)) &&
- EXPECTED(memcmp(p->key->val, Z_STRVAL_P(varname), Z_STRLEN_P(varname)) == 0)))) {
- value = &EG(symbol_table).ht.arData[idx].val;
- goto check_indirect;
+ if (EG(exception) != NULL) {
+ HANDLE_EXCEPTION();
+ }
+
+ /* No exception raised: Skip over arguments until fcall opcode with correct
+ * nesting level. Return NULL (except when return value unused) */
+ do {
+ opline++;
+ if (opline->opcode == ZEND_INIT_FCALL ||
+ opline->opcode == ZEND_INIT_FCALL_BY_NAME ||
+ opline->opcode == ZEND_INIT_NS_FCALL_BY_NAME ||
+ opline->opcode == ZEND_INIT_METHOD_CALL ||
+ opline->opcode == ZEND_INIT_STATIC_METHOD_CALL ||
+ opline->opcode == ZEND_INIT_USER_CALL ||
+ opline->opcode == ZEND_NEW
+ ) {
+ nesting++;
+ } else if (opline->opcode == ZEND_DO_FCALL) {
+ nesting--;
+ }
+ } while (nesting);
+
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+
+ /* We've skipped EXT_FCALL_BEGIND, so also skip the ending opcode */
+ if ((opline + 1)->opcode == ZEND_EXT_FCALL_END) {
+ opline++;
+ }
+ ZEND_VM_JMP(++opline);
+ }
+
+ obj = Z_OBJ_P(object);
+ called_scope = obj->ce;
+
+ if (IS_CONST != IS_CONST ||
+ EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
+ zend_object *orig_obj = obj;
+
+ if (UNEXPECTED(obj->handlers->get_method == NULL)) {
+ zend_error_noreturn(E_ERROR, "Object does not support method calls");
+ }
+
+ /* First, locate the function. */
+ fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_CONST == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
+ if (UNEXPECTED(fbc == NULL)) {
+ zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
+ }
+ if (IS_CONST == IS_CONST &&
+ EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
+ EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
+ EXPECTED(obj == orig_obj)) {
+ CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope, fbc);
}
}
- value = zend_hash_find(&EG(symbol_table).ht, Z_STR_P(varname));
- if (UNEXPECTED(value == NULL)) {
- value = zend_hash_add_new(&EG(symbol_table).ht, Z_STR_P(varname), &EG(uninitialized_zval));
- idx = ((char*)value - (char*)EG(symbol_table).ht.arData) / sizeof(Bucket);
- /* Store "hash slot index" + 1 (NULL is a mark of uninitialized cache slot) */
- CACHE_PTR(Z_CACHE_SLOT_P(varname), (void*)(uintptr_t)(idx + 1));
+ if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_STATIC) != 0)) {
+ obj = NULL;
} else {
- idx = ((char*)value - (char*)EG(symbol_table).ht.arData) / sizeof(Bucket);
- /* Store "hash slot index" + 1 (NULL is a mark of uninitialized cache slot) */
- CACHE_PTR(Z_CACHE_SLOT_P(varname), (void*)(uintptr_t)(idx + 1));
-check_indirect:
- /* GLOBAL variable may be an INDIRECT pointer to CV */
- if (UNEXPECTED(Z_TYPE_P(value) == IS_INDIRECT)) {
- value = Z_INDIRECT_P(value);
- if (UNEXPECTED(Z_TYPE_P(value) == IS_UNDEF)) {
- ZVAL_NULL(value);
- }
- }
+ GC_REFCOUNT(obj)++; /* For $this pointer */
}
- variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- zend_assign_to_variable_reference(variable_ptr, value TSRMLS_CC);
+ EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
+ fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_MOD_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_CASE_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
+
+ zval *result = EX_VAR(opline->result.var);
SAVE_OPLINE();
- fast_mod_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ fast_equal_function(result,
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ opline->op2.zv TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_SL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
- SAVE_OPLINE();
- shift_left_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ zval *expr_ptr, new_expr;
- zval_ptr_dtor_nogc(free_op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ SAVE_OPLINE();
+ if ((IS_CV == IS_VAR || IS_CV == IS_CV) &&
+ (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
+ expr_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ if (IS_CV == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
+ }
+ ZVAL_MAKE_REF(expr_ptr);
+ Z_ADDREF_P(expr_ptr);
-static int ZEND_FASTCALL ZEND_SR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
+ } else {
+ expr_ptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ if (IS_CV == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&new_expr, expr_ptr);
+ expr_ptr = &new_expr;
+ } else if (IS_CV == IS_CONST) {
+ if (!Z_IMMUTABLE_P(expr_ptr)) {
+ ZVAL_DUP(&new_expr, expr_ptr);
+ expr_ptr = &new_expr;
+ }
+ } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(expr_ptr)) {
+ expr_ptr = Z_REFVAL_P(expr_ptr);
+ if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
- SAVE_OPLINE();
- shift_right_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ } else if (IS_CV == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
+ Z_ADDREF_P(expr_ptr);
+ }
+ }
- zval_ptr_dtor_nogc(free_op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ if (IS_CONST != IS_UNUSED) {
-static int ZEND_FASTCALL ZEND_CONCAT_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
+ zval *offset = opline->op2.zv;
+ zend_string *str;
+ zend_ulong hval;
- SAVE_OPLINE();
- concat_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+add_again:
+ switch (Z_TYPE_P(offset)) {
+ case IS_DOUBLE:
+ hval = zend_dval_to_lval(Z_DVAL_P(offset));
+ goto num_index;
+ case IS_LONG:
+ hval = Z_LVAL_P(offset);
+num_index:
+ zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
+ break;
+ case IS_STRING:
+ str = Z_STR_P(offset);
+ if (IS_CONST != IS_CONST) {
+ if (ZEND_HANDLE_NUMERIC(str, hval)) {
+ goto num_index;
+ }
+ }
+str_index:
+ zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
+ break;
+ case IS_NULL:
+ str = STR_EMPTY_ALLOC();
+ goto str_index;
+ case IS_FALSE:
+ hval = 0;
+ goto num_index;
+ case IS_TRUE:
+ hval = 1;
+ goto num_index;
+ case IS_REFERENCE:
+ offset = Z_REFVAL_P(offset);
+ goto add_again;
+ break;
+ default:
+ zend_error(E_WARNING, "Illegal offset type");
+ zval_ptr_dtor(expr_ptr);
+ /* do nothing */
+ break;
+ }
- zval_ptr_dtor_nogc(free_op2);
+ } else {
+ zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
+ }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_IS_IDENTICAL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+ zval *array;
+ uint32_t size;
USE_OPLINE
- zend_free_op free_op2;
- SAVE_OPLINE();
- fast_is_identical_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ array = EX_VAR(opline->result.var);
+ if (IS_CV != IS_UNUSED) {
+ size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
+ } else {
+ size = 0;
+ }
+ ZVAL_NEW_ARR(array);
+ zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
- zval_ptr_dtor_nogc(free_op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (IS_CV != IS_UNUSED) {
+ /* Explicitly initialize array as not-packed if flag is set */
+ if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
+ zend_hash_real_init(Z_ARRVAL_P(array), 0);
+ }
+ }
+
+ if (IS_CV == IS_UNUSED) {
+ ZEND_VM_NEXT_OPCODE();
+#if 0 || IS_CV != IS_UNUSED
+ } else {
+ return ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+#endif
+ }
}
-static int ZEND_FASTCALL ZEND_IS_NOT_IDENTICAL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_UNSET_VAR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
- zval *result = EX_VAR(opline->result.var);
+ zval tmp, *varname;
+ HashTable *target_symbol_table;
+
SAVE_OPLINE();
- fast_is_not_identical_function(result,
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ if (IS_CV == IS_CV &&
+ IS_CONST == IS_UNUSED &&
+ (opline->extended_value & ZEND_QUICK_SET)) {
+ zval *var = EX_VAR(opline->op1.var);
- zval_ptr_dtor_nogc(free_op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ if (Z_REFCOUNTED_P(var)) {
+ zend_refcounted *garbage = Z_COUNTED_P(var);
-static int ZEND_FASTCALL ZEND_BW_OR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
+ if (!--GC_REFCOUNT(garbage)) {
+ ZVAL_UNDEF(var);
+ _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
+ } else {
+ GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
+ ZVAL_UNDEF(var);
+ }
+ } else {
+ ZVAL_UNDEF(var);
+ }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
- SAVE_OPLINE();
- bitwise_or_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ varname = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ ZVAL_UNDEF(&tmp);
+ if (IS_CV != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
+ ZVAL_STR(&tmp, zval_get_string(varname));
+ varname = &tmp;
+ }
-static int ZEND_FASTCALL ZEND_BW_AND_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
+ if (IS_CONST != IS_UNUSED) {
+ zend_class_entry *ce;
- SAVE_OPLINE();
- bitwise_and_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ if (IS_CONST == IS_CONST) {
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ } else {
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ if (IS_CV != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+ zend_string_release(Z_STR(tmp));
+ }
+
+ HANDLE_EXCEPTION();
+ }
+ if (UNEXPECTED(ce == NULL)) {
+ zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
+ }
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+ }
+ } else {
+ ce = Z_CE_P(EX_VAR(opline->op2.var));
+ }
+ zend_std_unset_static_property(ce, Z_STR_P(varname), ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+ } else {
+ target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+ zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
+ }
+
+ if (IS_CV != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+ zend_string_release(Z_STR(tmp));
+ }
- zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_BW_XOR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_UNSET_DIM_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
+
+ zval *container;
+ zval *offset;
+ zend_ulong hval;
SAVE_OPLINE();
- bitwise_xor_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
+ }
+ if (IS_CV != IS_UNUSED) {
+ ZVAL_DEREF(container);
+ }
+ SEPARATE_ZVAL_NOREF(container);
+ offset = opline->op2.zv;
- zval_ptr_dtor_nogc(free_op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ if (IS_CV != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
+ HashTable *ht = Z_ARRVAL_P(container);
+offset_again:
+ switch (Z_TYPE_P(offset)) {
+ case IS_DOUBLE:
+ hval = zend_dval_to_lval(Z_DVAL_P(offset));
+ zend_hash_index_del(ht, hval);
+ break;
+ case IS_LONG:
+ hval = Z_LVAL_P(offset);
+num_index_dim:
+ zend_hash_index_del(ht, hval);
+ break;
+ case IS_STRING:
+ if (IS_CONST != IS_CONST) {
+ if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
+ goto num_index_dim;
+ }
+ }
+ if (ht == &EG(symbol_table).ht) {
+ zend_delete_global_variable(Z_STR_P(offset) TSRMLS_CC);
+ } else {
+ zend_hash_del(ht, Z_STR_P(offset));
+ }
+ break;
+ case IS_NULL:
+ zend_hash_del(ht, STR_EMPTY_ALLOC());
+ break;
+ case IS_FALSE:
+ hval = 0;
+ goto num_index_dim;
+ case IS_TRUE:
+ hval = 1;
+ goto num_index_dim;
+ case IS_RESOURCE:
+ hval = Z_RES_HANDLE_P(offset);
+ goto num_index_dim;
+ case IS_REFERENCE:
+ offset = Z_REFVAL_P(offset);
+ goto offset_again;
+ break;
+ default:
+ zend_error(E_WARNING, "Illegal offset type in unset");
+ break;
+ }
-static int ZEND_FASTCALL ZEND_BOOL_XOR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
+ } else if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use object as array");
+ }
+//??? if (IS_CONST == IS_CONST) {
+//??? zval_copy_ctor(offset);
+//??? }
+ Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
- SAVE_OPLINE();
- boolean_xor_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
+ ZEND_VM_CONTINUE(); /* bailed out before */
+ } else {
+
+ }
- zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_UNSET_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2, free_op_data1;
- zval *object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- zval *property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- zval *value;
- zval *zptr;
- if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+ zval *container;
+ zval *offset;
+
+ SAVE_OPLINE();
+ container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
}
+ offset = opline->op2.zv;
if (IS_CV != IS_UNUSED) {
- object = make_real_object(object TSRMLS_CC);
+ ZVAL_DEREF(container);
}
-
- value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-
- if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to assign property of non-object");
- zval_ptr_dtor_nogc(free_op2);
- FREE_OP(free_op_data1);
-
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- } else {
- /* here we are sure we are dealing with an object */
- if (opline->extended_value == ZEND_ASSIGN_OBJ
- && EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
-
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
-
- binary_op(zptr, zptr, value TSRMLS_CC);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), zptr);
- }
+ if (IS_CV == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
+ if (Z_OBJ_HT_P(container)->unset_property) {
+ Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
} else {
- zval *z = NULL;
- zval rv;
-
- if (opline->extended_value == ZEND_ASSIGN_OBJ) {
- if (Z_OBJ_HT_P(object)->read_property) {
- z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
- }
- } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
- if (Z_OBJ_HT_P(object)->read_dimension) {
- z = Z_OBJ_HT_P(object)->read_dimension(object, property, BP_VAR_R, &rv TSRMLS_CC);
- }
- }
- if (z) {
- if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
- zval rv;
- zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
-
- if (Z_REFCOUNT_P(z) == 0) {
- zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
- }
- ZVAL_COPY_VALUE(z, value);
- }
-//??? if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
- SEPARATE_ZVAL_IF_NOT_REF(z);
- binary_op(z, z, value TSRMLS_CC);
- if (opline->extended_value == ZEND_ASSIGN_OBJ) {
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
- } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
- Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
- }
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), z);
- }
- zval_ptr_dtor(z);
- } else {
- zend_error(E_WARNING, "Attempt to assign property of non-object");
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- }
+ zend_error(E_NOTICE, "Trying to unset property of non-object");
}
-
- zval_ptr_dtor_nogc(free_op2);
- FREE_OP(free_op_data1);
}
- /* assign_obj has two opcodes! */
+
CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_CV_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_VAR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2, free_op_data1;
- zval *var_ptr, rv;
- zval *value, *container;
+ zval *value;
SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- if (IS_CV != IS_UNUSED) {
- ZVAL_DEREF(container);
- }
- if (IS_CV == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (IS_CV == IS_VAR && !0) {
- Z_ADDREF_P(container); /* undo the effect of get_obj_zval_ptr_ptr() */
+ if (IS_CV == IS_CV &&
+ IS_CONST == IS_UNUSED &&
+ (opline->extended_value & ZEND_QUICK_SET)) {
+ value = EX_VAR(opline->op1.var);
+ if (opline->extended_value & ZEND_ISSET) {
+ ZVAL_BOOL(EX_VAR(opline->result.var),
+ Z_TYPE_P(value) > IS_NULL &&
+ (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+ } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+ ZVAL_BOOL(EX_VAR(opline->result.var),
+ !i_zend_is_true(value TSRMLS_CC));
+ CHECK_EXCEPTION();
}
- return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_NEXT_OPCODE();
} else {
- zval *dim = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- zend_fetch_dimension_address_RW(&rv, container, dim, IS_TMP_VAR TSRMLS_CC);
- value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
- var_ptr = Z_INDIRECT(rv);
- }
+ zval tmp, *varname = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
- if (UNEXPECTED(var_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
- }
+ ZVAL_UNDEF(&tmp);
+ if (IS_CV != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
+ ZVAL_STR(&tmp, zval_get_string(varname));
+ varname = &tmp;
+ }
- if (UNEXPECTED(var_ptr == &EG(error_zval))) {
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_NULL(EX_VAR(opline->result.var));
+ if (IS_CONST != IS_UNUSED) {
+ zend_class_entry *ce;
+
+ if (IS_CONST == IS_CONST) {
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ } else {
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+ if (UNEXPECTED(ce == NULL)) {
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+ }
+ } else {
+ ce = Z_CE_P(EX_VAR(opline->op2.var));
+ }
+ value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+ } else {
+ HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+ value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
}
- } else {
- ZVAL_DEREF(var_ptr);
- SEPARATE_ZVAL_NOREF(var_ptr);
- binary_op(var_ptr, var_ptr, value TSRMLS_CC);
-
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+ if (IS_CV != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+ zend_string_release(Z_STR(tmp));
}
- }
- zval_ptr_dtor_nogc(free_op2);
- FREE_OP(free_op_data1);
+ if (opline->extended_value & ZEND_ISSET) {
+ ZVAL_BOOL(EX_VAR(opline->result.var),
+ value && Z_TYPE_P(value) > IS_NULL &&
+ (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+ } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+ ZVAL_BOOL(EX_VAR(opline->result.var),
+ !value || !i_zend_is_true(value TSRMLS_CC));
+ }
- CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
}
-static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
- zval *var_ptr;
- zval *value;
+
+ zval *container;
+ int result;
+ zend_ulong hval;
+ zval *offset;
SAVE_OPLINE();
- value = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+ container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
+ offset = opline->op2.zv;
- if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
- }
+ if (IS_CV != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
+ HashTable *ht = Z_ARRVAL_P(container);
+ zval *value;
+ zend_string *str;
- if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_NULL(EX_VAR(opline->result.var));
+isset_again:
+ if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
+ str = Z_STR_P(offset);
+ if (IS_CONST != IS_CONST) {
+ if (ZEND_HANDLE_NUMERIC(str, hval)) {
+ goto num_index_prop;
+ }
+ }
+str_index_prop:
+ value = zend_hash_find_ind(ht, str);
+ } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
+ hval = Z_LVAL_P(offset);
+num_index_prop:
+ value = zend_hash_index_find(ht, hval);
+ } else {
+ switch (Z_TYPE_P(offset)) {
+ case IS_DOUBLE:
+ hval = zend_dval_to_lval(Z_DVAL_P(offset));
+ goto num_index_prop;
+ case IS_NULL:
+ str = STR_EMPTY_ALLOC();
+ goto str_index_prop;
+ case IS_FALSE:
+ hval = 0;
+ goto num_index_prop;
+ case IS_TRUE:
+ hval = 1;
+ goto num_index_prop;
+ case IS_RESOURCE:
+ hval = Z_RES_HANDLE_P(offset);
+ goto num_index_prop;
+ case IS_REFERENCE:
+ offset = Z_REFVAL_P(offset);
+ goto isset_again;
+ default:
+ zend_error(E_WARNING, "Illegal offset type in isset or empty");
+ value = NULL;
+ break;
+ }
}
- } else {
- ZVAL_DEREF(var_ptr);
- SEPARATE_ZVAL_NOREF(var_ptr);
- binary_op(var_ptr, var_ptr, value TSRMLS_CC);
+ if (opline->extended_value & ZEND_ISSET) {
+ /* > IS_NULL means not IS_UNDEF and not IS_NULL */
+ result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
+ (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
+ } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+ result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
+ }
+ } else if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
+ result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
+ } else {
+ zend_error(E_NOTICE, "Trying to check element of non-array");
+ result = 0;
+ }
+ if ((opline->extended_value & ZEND_ISSET) == 0) {
+ result = !result;
+ }
+ } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
+ zval tmp;
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+ result = 0;
+ if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
+ if (IS_CONST & (IS_CV|IS_VAR)) {
+ ZVAL_DEREF(offset);
+ }
+ if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
+ || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
+ && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
+ ZVAL_DUP(&tmp, offset);
+ convert_to_long(&tmp);
+ offset = &tmp;
+ }
+ }
+ if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
+ if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
+ if ((opline->extended_value & ZEND_ISSET) ||
+ Z_STRVAL_P(container)[offset->value.lval] != '0') {
+ result = 1;
+ }
+ }
+ }
+ if ((opline->extended_value & ZEND_ISSET) == 0) {
+ result = !result;
}
+ } else {
+ result = ((opline->extended_value & ZEND_ISSET) == 0);
}
- zval_ptr_dtor_nogc(free_op2);
+ ZVAL_BOOL(EX_VAR(opline->result.var), result);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
+ zval *container;
+ int result;
+ zval *offset;
-static int ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ SAVE_OPLINE();
+ container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
+ offset = opline->op2.zv;
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
+ result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+ } else {
+ zend_error(E_NOTICE, "Trying to check property of non-object");
+ result = 0;
+ }
+ if ((opline->extended_value & ZEND_ISSET) == 0) {
+ result = !result;
+ }
+ } else {
+ result = ((opline->extended_value & ZEND_ISSET) == 0);
}
-}
-static int ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ ZVAL_BOOL(EX_VAR(opline->result.var), result);
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INSTANCEOF_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
+ zval *expr;
+ zend_bool result;
-static int ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ SAVE_OPLINE();
+ expr = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
+ if (Z_TYPE_P(expr) == IS_OBJECT) {
+ zend_class_entry *ce;
-static int ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ if (IS_CONST == IS_CONST) {
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ } else {
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, ZEND_FETCH_CLASS_NO_AUTOLOAD TSRMLS_CC);
+ if (UNEXPECTED(ce == NULL)) {
+ ZVAL_FALSE(EX_VAR(opline->result.var));
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+ }
+ } else {
+ ce = Z_CE_P(EX_VAR(opline->op2.var));
+ }
+ result = instanceof_function(Z_OBJCE_P(expr), ce TSRMLS_CC);
+ } else {
+ result = 0;
}
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ ZVAL_BOOL(EX_VAR(opline->result.var), result);
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_YIELD_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ /* The generator object is stored in EX(return_value) */
+ zend_generator *generator = (zend_generator *) EX(return_value);
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
+ zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
}
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
+ /* Destroy the previously yielded value */
+ zval_ptr_dtor(&generator->value);
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ /* Destroy the previously yielded key */
+ zval_ptr_dtor(&generator->key);
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
+ /* Set the new yielded value */
+ if (IS_CV != IS_UNUSED) {
-static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_TMP(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
- zval *object;
- zval *property;
- zval *retval;
- zval *zptr;
- SAVE_OPLINE();
- object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- retval = EX_VAR(opline->result.var);
+ if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
+ /* Constants and temporary variables aren't yieldable by reference,
+ * but we still allow them with a notice. */
+ if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
+ zval *value;
- if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
+ zend_error(E_NOTICE, "Only variable references should be yielded by reference");
- if (IS_CV != IS_UNUSED) {
- object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
- }
+ value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ ZVAL_COPY_VALUE(&generator->value, value);
+ if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
- if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- zval_ptr_dtor_nogc(free_op2);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(retval);
- }
+ /* Temporary variables don't need ctor copying */
+ if (IS_CV != IS_TMP_VAR) {
+ zval_opt_copy_ctor(&generator->value);
+ }
+ } else {
+ zval *value_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
+ if (IS_CV == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
+ }
- /* here we are sure we are dealing with an object */
+ /* If a function call result is yielded and the function did
+ * not return by reference we throw a notice. */
+ if (IS_CV == IS_VAR &&
+ (value_ptr == &EG(uninitialized_zval) ||
+ (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+ !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+ zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+ } else {
+ ZVAL_MAKE_REF(value_ptr);
+ }
+ ZVAL_COPY(&generator->value, value_ptr);
- if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+ }
+ } else {
+ zval *value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
+ /* Consts, temporary variables and references need copying */
+ if (IS_CV == IS_CONST) {
+ ZVAL_DUP(&generator->value, value);
+ } else if (IS_CV == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&generator->value, value);
+ } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(value)) {
+ ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
- incdec_op(zptr);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(retval, zptr);
+ } else {
+ ZVAL_COPY_VALUE(&generator->value, value);
+ if (IS_CV == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+ }
+ }
}
} else {
- zval rv;
+ /* If no value was specified yield null */
+ ZVAL_NULL(&generator->value);
+ }
- if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+ /* Set the new yielded key */
+ if (IS_CONST != IS_UNUSED) {
- if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
- zval rv;
- zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+ zval *key = opline->op2.zv;
+
+ /* Consts, temporary variables and references need copying */
+ if (IS_CONST == IS_CONST) {
+ ZVAL_DUP(&generator->key, key);
+ } else if (IS_CONST == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&generator->key, key);
+ } else if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) && Z_ISREF_P(key)) {
+ ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
- if (Z_REFCOUNT_P(z) == 0) {
- zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
- }
- ZVAL_COPY_VALUE(z, value);
- }
- if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
- SEPARATE_ZVAL_IF_NOT_REF(z);
- incdec_op(z);
- ZVAL_COPY_VALUE(retval, z);
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
- SELECTIVE_PZVAL_LOCK(retval, opline);
- zval_ptr_dtor(z);
} else {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(retval);
+ ZVAL_COPY_VALUE(&generator->key, key);
+ if (IS_CONST == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
}
}
+
+ if (Z_TYPE(generator->key) == IS_LONG
+ && Z_LVAL(generator->key) > generator->largest_used_integer_key
+ ) {
+ generator->largest_used_integer_key = Z_LVAL(generator->key);
+ }
+ } else {
+ /* If no key was specified we use auto-increment keys */
+ generator->largest_used_integer_key++;
+ ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
}
- zval_ptr_dtor_nogc(free_op2);
+ if (RETURN_VALUE_USED(opline)) {
+ /* If the return value of yield is used set the send
+ * target and initialize it to NULL */
+ generator->send_target = EX_VAR(opline->result.var);
+ ZVAL_NULL(generator->send_target);
+ } else {
+ generator->send_target = NULL;
+ }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ /* We increment to the next op, so we are at the correct position when the
+ * generator is resumed. */
+ ZEND_VM_INC_OPCODE();
-static int ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_pre_incdec_property_helper_SPEC_CV_TMP(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ /* The GOTO VM uses a local opline variable. We need to set the opline
+ * variable in execute_data so we don't resume at an old position. */
+ SAVE_OPLINE();
-static int ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_pre_incdec_property_helper_SPEC_CV_TMP(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ ZEND_VM_RETURN();
}
-static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_TMP(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_POW_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
- zval *object;
- zval *property;
- zval *retval;
- zval *zptr;
+
SAVE_OPLINE();
- object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- retval = EX_VAR(opline->result.var);
+ pow_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ opline->op2.zv TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
- if (IS_CV != IS_UNUSED) {
- object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
- }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- zval_ptr_dtor_nogc(free_op2);
- ZVAL_NULL(retval);
+static int ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_binary_assign_op_helper_SPEC_CV_CONST(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
+static int ZEND_FASTCALL ZEND_BIND_GLOBAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- /* here we are sure we are dealing with an object */
+ zval *varname;
+ zval *value;
+ zval *variable_ptr;
+ uint32_t idx;
- if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+ SAVE_OPLINE();
+ varname = opline->op2.zv;
- ZVAL_DEREF(zptr);
- ZVAL_COPY_VALUE(retval, zptr);
- zval_opt_copy_ctor(zptr);
+ /* We store "hash slot index" + 1 (NULL is a mark of uninitialized cache slot) */
+ idx = (uint32_t)(uintptr_t)CACHED_PTR(Z_CACHE_SLOT_P(varname)) - 1;
+ if (EXPECTED(idx < EG(symbol_table).ht.nNumUsed)) {
+ Bucket *p = EG(symbol_table).ht.arData + idx;
- incdec_op(zptr);
- } else {
- if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval rv;
- zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
- zval z_copy;
+ if (EXPECTED(Z_TYPE(p->val) != IS_UNDEF) &&
+ (EXPECTED(p->key == Z_STR_P(varname)) ||
+ (EXPECTED(p->h == Z_STR_P(varname)->h) &&
+ EXPECTED(p->key != NULL) &&
+ EXPECTED(p->key->len == Z_STRLEN_P(varname)) &&
+ EXPECTED(memcmp(p->key->val, Z_STRVAL_P(varname), Z_STRLEN_P(varname)) == 0)))) {
- if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
- zval rv;
- zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+ value = &EG(symbol_table).ht.arData[idx].val;
+ goto check_indirect;
+ }
+ }
- if (Z_REFCOUNT_P(z) == 0) {
- zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
- }
- ZVAL_COPY_VALUE(z, value);
+ value = zend_hash_find(&EG(symbol_table).ht, Z_STR_P(varname));
+ if (UNEXPECTED(value == NULL)) {
+ value = zend_hash_add_new(&EG(symbol_table).ht, Z_STR_P(varname), &EG(uninitialized_zval));
+ idx = ((char*)value - (char*)EG(symbol_table).ht.arData) / sizeof(Bucket);
+ /* Store "hash slot index" + 1 (NULL is a mark of uninitialized cache slot) */
+ CACHE_PTR(Z_CACHE_SLOT_P(varname), (void*)(uintptr_t)(idx + 1));
+ } else {
+ idx = ((char*)value - (char*)EG(symbol_table).ht.arData) / sizeof(Bucket);
+ /* Store "hash slot index" + 1 (NULL is a mark of uninitialized cache slot) */
+ CACHE_PTR(Z_CACHE_SLOT_P(varname), (void*)(uintptr_t)(idx + 1));
+check_indirect:
+ /* GLOBAL variable may be an INDIRECT pointer to CV */
+ if (UNEXPECTED(Z_TYPE_P(value) == IS_INDIRECT)) {
+ value = Z_INDIRECT_P(value);
+ if (UNEXPECTED(Z_TYPE_P(value) == IS_UNDEF)) {
+ ZVAL_NULL(value);
}
- ZVAL_DUP(retval, z);
- ZVAL_DUP(&z_copy, z);
- incdec_op(&z_copy);
- if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
- Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
- zval_ptr_dtor(&z_copy);
- zval_ptr_dtor(z);
- } else {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- ZVAL_NULL(retval);
}
}
- zval_ptr_dtor_nogc(free_op2);
+ variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ zend_assign_to_variable_reference(variable_ptr, value TSRMLS_CC);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_post_incdec_property_helper_SPEC_CV_TMP(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_post_incdec_property_helper_SPEC_CV_TMP(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_MOD_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op2;
- zval *container;
SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ fast_mod_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_W_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *container;
+ zend_free_op free_op2;
SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ shift_left_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
zval_ptr_dtor_nogc(free_op2);
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
-
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_RW_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *container;
+ zend_free_op free_op2;
SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+ shift_right_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
zval_ptr_dtor_nogc(free_op2);
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
-
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_IS_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_CONCAT_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op2;
- zval *container;
SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
- zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ concat_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_IS_IDENTICAL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *container;
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op2;
SAVE_OPLINE();
+ fast_is_identical_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
- zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
- }
- container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
- zval_ptr_dtor_nogc(free_op2);
-
- } else {
- if (IS_TMP_VAR == IS_UNUSED) {
- zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
- }
- container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
-
- }
+ zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_UNSET_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_IS_NOT_IDENTICAL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *container;
+ zend_free_op free_op2;
+ zval *result = EX_VAR(opline->result.var);
SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
+ fast_is_not_identical_function(result,
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
zval_ptr_dtor_nogc(free_op2);
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
-
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BW_OR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
- zval *container;
zend_free_op free_op2;
- zval *offset;
SAVE_OPLINE();
- container = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-
- if ((IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
- UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
- zend_error(E_NOTICE, "Trying to get property of non-object");
- ZVAL_NULL(EX_VAR(opline->result.var));
- } else {
- zval *retval;
-
- /* here we are sure we are dealing with an object */
- do {
- if (IS_TMP_VAR == IS_CONST &&
- EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
- zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
- zend_object *zobj = Z_OBJ_P(container);
-
- if (EXPECTED(prop_info)) {
- retval = OBJ_PROP(zobj, prop_info->offset);
- if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- } else if (EXPECTED(zobj->properties != NULL)) {
- retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
- if (EXPECTED(retval)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- }
- }
-
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
-
- if (retval != EX_VAR(opline->result.var)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- }
- } while (0);
- }
+ bitwise_or_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op2);
-
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_W_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BW_AND_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *property;
- zval *container;
+ zend_free_op free_op2;
SAVE_OPLINE();
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-
- container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
+ bitwise_and_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
zval_ptr_dtor_nogc(free_op2);
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
-
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_RW_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BW_XOR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *property;
- zval *container;
+ zend_free_op free_op2;
SAVE_OPLINE();
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+ bitwise_xor_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
zval_ptr_dtor_nogc(free_op2);
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
-
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_BOOL_XOR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
- zval *container;
zend_free_op free_op2;
- zval *offset;
SAVE_OPLINE();
- container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-
- if ((IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
- UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- } else {
- zval *retval;
-
- /* here we are sure we are dealing with an object */
- do {
- if (IS_TMP_VAR == IS_CONST &&
- EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
- zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
- zend_object *zobj = Z_OBJ_P(container);
-
- if (EXPECTED(prop_info)) {
- retval = OBJ_PROP(zobj, prop_info->offset);
- if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- } else if (EXPECTED(zobj->properties != NULL)) {
- retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
- if (EXPECTED(retval)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- }
- }
-
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
-
- if (retval != EX_VAR(opline->result.var)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- }
- } while (0);
- }
+ boolean_xor_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
zval_ptr_dtor_nogc(free_op2);
-
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *container;
+ zend_free_op free_op2, free_op_data1;
+ zval *object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+ zval *property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ zval *value;
+ zval *zptr;
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- /* Behave like FETCH_OBJ_W */
- zend_free_op free_op1, free_op2;
- zval *property;
+ if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+ }
- SAVE_OPLINE();
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ if (IS_CV != IS_UNUSED) {
+ object = make_real_object(object TSRMLS_CC);
+ }
- if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
- zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
- }
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+ value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+
+ if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ zend_error(E_WARNING, "Attempt to assign property of non-object");
zval_ptr_dtor_nogc(free_op2);
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
+ FREE_OP(free_op_data1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
} else {
- return ZEND_FETCH_OBJ_R_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_UNSET_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *container, *property;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
- property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ /* here we are sure we are dealing with an object */
+ if (opline->extended_value == ZEND_ASSIGN_OBJ
+ && EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
+ ZVAL_DEREF(zptr);
+ SEPARATE_ZVAL_NOREF(zptr);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ binary_op(zptr, zptr, value TSRMLS_CC);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), zptr);
+ }
+ } else {
+ zval *z = NULL;
+ zval rv;
-static int ZEND_FASTCALL ZEND_ASSIGN_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
- zval *object;
- zval *property_name;
+ if (opline->extended_value == ZEND_ASSIGN_OBJ) {
+ if (Z_OBJ_HT_P(object)->read_property) {
+ z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+ }
+ } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
+ if (Z_OBJ_HT_P(object)->read_dimension) {
+ z = Z_OBJ_HT_P(object)->read_dimension(object, property, BP_VAR_R, &rv TSRMLS_CC);
+ }
+ }
+ if (z) {
+ if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+ zval rv;
+ zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
- SAVE_OPLINE();
- object = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- property_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ if (Z_REFCOUNT_P(z) == 0) {
+ zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
+ }
+ ZVAL_COPY_VALUE(z, value);
+ }
+//??? if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
+ SEPARATE_ZVAL_IF_NOT_REF(z);
+ binary_op(z, z, value TSRMLS_CC);
+ if (opline->extended_value == ZEND_ASSIGN_OBJ) {
+ Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+ } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
+ Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
+ }
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), z);
+ }
+ zval_ptr_dtor(z);
+ } else {
+ zend_error(E_WARNING, "Attempt to assign property of non-object");
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ }
+ }
- if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ zval_ptr_dtor_nogc(free_op2);
+ FREE_OP(free_op_data1);
}
- zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
/* assign_obj has two opcodes! */
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_DIM_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_CV_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
- zval *object_ptr;
+ zend_free_op free_op2, free_op_data1;
+ zval *var_ptr, rv;
+ zval *value, *container;
SAVE_OPLINE();
- object_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-
- if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
+ container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
- ZVAL_DEREF(object_ptr);
- if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
- zend_free_op free_op2;
- zval *property_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-
- zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ if (IS_CV != IS_UNUSED) {
+ ZVAL_DEREF(container);
+ }
+ if (IS_CV == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ if (IS_CV == IS_VAR && !0) {
+ Z_ADDREF_P(container); /* undo the effect of get_obj_zval_ptr_ptr() */
+ }
+ return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else {
- zend_free_op free_op2, free_op_data1;
- zval rv;
- zval *value;
zval *dim = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- zval *variable_ptr;
- if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
- EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
- zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
- FREE_OP(free_op_data1);
- } else {
- zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_TMP_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
- variable_ptr = Z_INDIRECT(rv);
- if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
- FREE_OP(free_op_data1);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- } else {
- value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
- if ((opline+1)->op1_type == IS_VAR) {
- FREE_OP(free_op_data1);
- }
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), value);
- }
- }
+ zend_fetch_dimension_address_RW(&rv, container, dim, IS_TMP_VAR TSRMLS_CC);
+ value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+ ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+ var_ptr = Z_INDIRECT(rv);
+ }
+
+ if (UNEXPECTED(var_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
+ }
+
+ if (UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
+
+ binary_op(var_ptr, var_ptr, value TSRMLS_CC);
+
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
}
}
- /* assign_dim has two opcodes! */
+ zval_ptr_dtor_nogc(free_op2);
+ FREE_OP(free_op_data1);
+
CHECK_EXCEPTION();
ZEND_VM_INC_OPCODE();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op2;
+ zval *var_ptr;
zval *value;
- zval *variable_ptr;
SAVE_OPLINE();
value = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
- if (IS_TMP_VAR == IS_TMP_VAR) {
- zval_ptr_dtor_nogc(free_op2);
- }
- if (RETURN_VALUE_USED(opline)) {
+ if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
+ }
+
+ if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
ZVAL_NULL(EX_VAR(opline->result.var));
}
} else {
- value = zend_assign_to_variable(variable_ptr, value, IS_TMP_VAR TSRMLS_CC);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), value);
- }
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
+
+ binary_op(var_ptr, var_ptr, value TSRMLS_CC);
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+ }
}
- /* zend_assign_to_variable() always takes care of op2, never free it! */
+ zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *function_name;
- zend_free_op free_op2;
- zval *object;
- zend_function *fbc;
- zend_class_entry *called_scope;
- zend_object *obj;
- SAVE_OPLINE();
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
- function_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+static int ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- if (IS_TMP_VAR != IS_CONST &&
- UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- zend_error_noreturn(E_ERROR, "Method name must be a string");
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
+}
- object = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+static int ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- uint32_t nesting = 1;
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
- if (UNEXPECTED(EG(exception) != NULL)) {
- zval_ptr_dtor_nogc(free_op2);
- HANDLE_EXCEPTION();
- }
+static int ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s", Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
- zval_ptr_dtor_nogc(free_op2);
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
- if (EG(exception) != NULL) {
- HANDLE_EXCEPTION();
- }
+static int ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- /* No exception raised: Skip over arguments until fcall opcode with correct
- * nesting level. Return NULL (except when return value unused) */
- do {
- opline++;
- if (opline->opcode == ZEND_INIT_FCALL ||
- opline->opcode == ZEND_INIT_FCALL_BY_NAME ||
- opline->opcode == ZEND_INIT_NS_FCALL_BY_NAME ||
- opline->opcode == ZEND_INIT_METHOD_CALL ||
- opline->opcode == ZEND_INIT_STATIC_METHOD_CALL ||
- opline->opcode == ZEND_INIT_USER_CALL ||
- opline->opcode == ZEND_NEW
- ) {
- nesting++;
- } else if (opline->opcode == ZEND_DO_FCALL) {
- nesting--;
- }
- } while (nesting);
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
+static int ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- /* We've skipped EXT_FCALL_BEGIND, so also skip the ending opcode */
- if ((opline + 1)->opcode == ZEND_EXT_FCALL_END) {
- opline++;
- }
- ZEND_VM_JMP(++opline);
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
+}
- obj = Z_OBJ_P(object);
- called_scope = obj->ce;
+static int ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- if (IS_TMP_VAR != IS_CONST ||
- EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
- zend_object *orig_obj = obj;
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
- if (UNEXPECTED(obj->handlers->get_method == NULL)) {
- zend_error_noreturn(E_ERROR, "Object does not support method calls");
- }
+static int ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- /* First, locate the function. */
- fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_TMP_VAR == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
- if (UNEXPECTED(fbc == NULL)) {
- zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
- }
- if (IS_TMP_VAR == IS_CONST &&
- EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
- EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
- EXPECTED(obj == orig_obj)) {
- CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope, fbc);
- }
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
+}
- if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_STATIC) != 0)) {
- obj = NULL;
- } else {
- GC_REFCOUNT(obj)++; /* For $this pointer */
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
+}
- EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
- fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- zval_ptr_dtor_nogc(free_op2);
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
}
-static int ZEND_FASTCALL ZEND_CASE_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op2;
- zval *result = EX_VAR(opline->result.var);
+ zval *container;
SAVE_OPLINE();
- fast_equal_function(result,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
-
+ container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
zval_ptr_dtor_nogc(free_op2);
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_W_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
- zval *expr_ptr, new_expr;
+ zend_free_op free_op1, free_op2;
+ zval *container;
SAVE_OPLINE();
- if ((IS_CV == IS_VAR || IS_CV == IS_CV) &&
- (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
- expr_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
- }
- ZVAL_MAKE_REF(expr_ptr);
- Z_ADDREF_P(expr_ptr);
-
- } else {
- expr_ptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&new_expr, expr_ptr);
- expr_ptr = &new_expr;
- } else if (IS_CV == IS_CONST) {
- if (!Z_IMMUTABLE_P(expr_ptr)) {
- ZVAL_DUP(&new_expr, expr_ptr);
- expr_ptr = &new_expr;
- }
- } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(expr_ptr)) {
- expr_ptr = Z_REFVAL_P(expr_ptr);
- if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
+ container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- } else if (IS_CV == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
- Z_ADDREF_P(expr_ptr);
- }
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
-
- if (IS_TMP_VAR != IS_UNUSED) {
- zend_free_op free_op2;
- zval *offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- zend_string *str;
- zend_ulong hval;
-
-add_again:
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- goto num_index;
- case IS_LONG:
- hval = Z_LVAL_P(offset);
-num_index:
- zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
- break;
- case IS_STRING:
- str = Z_STR_P(offset);
- if (IS_TMP_VAR != IS_CONST) {
- if (ZEND_HANDLE_NUMERIC(str, hval)) {
- goto num_index;
- }
- }
-str_index:
- zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
- break;
- case IS_NULL:
- str = STR_EMPTY_ALLOC();
- goto str_index;
- case IS_FALSE:
- hval = 0;
- goto num_index;
- case IS_TRUE:
- hval = 1;
- goto num_index;
- case IS_REFERENCE:
- offset = Z_REFVAL_P(offset);
- goto add_again;
- break;
- default:
- zend_error(E_WARNING, "Illegal offset type");
- zval_ptr_dtor(expr_ptr);
- /* do nothing */
- break;
- }
- zval_ptr_dtor_nogc(free_op2);
- } else {
- zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_RW_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- zval *array;
- uint32_t size;
USE_OPLINE
+ zend_free_op free_op1, free_op2;
+ zval *container;
- array = EX_VAR(opline->result.var);
- if (IS_CV != IS_UNUSED) {
- size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
- } else {
- size = 0;
- }
- ZVAL_NEW_ARR(array);
- zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
+ SAVE_OPLINE();
+ container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV != IS_UNUSED) {
- /* Explicitly initialize array as not-packed if flag is set */
- if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
- zend_hash_real_init(Z_ARRVAL_P(array), 0);
- }
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
-
- if (IS_CV == IS_UNUSED) {
- ZEND_VM_NEXT_OPCODE();
-#if 0 || IS_CV != IS_UNUSED
- } else {
- return ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-#endif
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_UNSET_DIM_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_IS_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op2;
zval *container;
- zval *offset;
- zend_ulong hval;
SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
- }
- if (IS_CV != IS_UNUSED) {
- ZVAL_DEREF(container);
- }
- SEPARATE_ZVAL_NOREF(container);
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ container = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
+ zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
- if (IS_CV != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
- HashTable *ht = Z_ARRVAL_P(container);
-offset_again:
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- zend_hash_index_del(ht, hval);
- break;
- case IS_LONG:
- hval = Z_LVAL_P(offset);
-num_index_dim:
- zend_hash_index_del(ht, hval);
- break;
- case IS_STRING:
- if (IS_TMP_VAR != IS_CONST) {
- if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
- goto num_index_dim;
- }
- }
- if (ht == &EG(symbol_table).ht) {
- zend_delete_global_variable(Z_STR_P(offset) TSRMLS_CC);
- } else {
- zend_hash_del(ht, Z_STR_P(offset));
- }
- break;
- case IS_NULL:
- zend_hash_del(ht, STR_EMPTY_ALLOC());
- break;
- case IS_FALSE:
- hval = 0;
- goto num_index_dim;
- case IS_TRUE:
- hval = 1;
- goto num_index_dim;
- case IS_RESOURCE:
- hval = Z_RES_HANDLE_P(offset);
- goto num_index_dim;
- case IS_REFERENCE:
- offset = Z_REFVAL_P(offset);
- goto offset_again;
- break;
- default:
- zend_error(E_WARNING, "Illegal offset type in unset");
- break;
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zval *container;
+ zend_free_op free_op1, free_op2;
+
+ SAVE_OPLINE();
+
+ if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+ if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
+ zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+ }
+ container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
- zval_ptr_dtor_nogc(free_op2);
- } else if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use object as array");
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
+ if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
-//??? if (IS_TMP_VAR == IS_CONST) {
-//??? zval_copy_ctor(offset);
-//??? }
- Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
zval_ptr_dtor_nogc(free_op2);
- } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
- ZEND_VM_CONTINUE(); /* bailed out before */
+
} else {
+ if (IS_TMP_VAR == IS_UNUSED) {
+ zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
+ }
+ container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
zval_ptr_dtor_nogc(free_op2);
- }
+ }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_UNSET_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_UNSET_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
+ zend_free_op free_op1, free_op2;
zval *container;
- zval *offset;
SAVE_OPLINE();
container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
- }
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- if (IS_CV != IS_UNUSED) {
- ZVAL_DEREF(container);
- }
- if (IS_CV == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
- if (Z_OBJ_HT_P(container)->unset_property) {
- Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to unset property of non-object");
- }
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
zval_ptr_dtor_nogc(free_op2);
+ if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_DIM_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
- zval *container;
- int result;
- zend_ulong hval;
- zval *offset;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- if (IS_CV != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
- HashTable *ht = Z_ARRVAL_P(container);
- zval *value;
- zend_string *str;
+ zval *object_ptr;
-isset_again:
- if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
- str = Z_STR_P(offset);
- if (IS_TMP_VAR != IS_CONST) {
- if (ZEND_HANDLE_NUMERIC(str, hval)) {
- goto num_index_prop;
- }
- }
-str_index_prop:
- value = zend_hash_find_ind(ht, str);
- } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
- hval = Z_LVAL_P(offset);
-num_index_prop:
- value = zend_hash_index_find(ht, hval);
- } else {
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- goto num_index_prop;
- case IS_NULL:
- str = STR_EMPTY_ALLOC();
- goto str_index_prop;
- case IS_FALSE:
- hval = 0;
- goto num_index_prop;
- case IS_TRUE:
- hval = 1;
- goto num_index_prop;
- case IS_RESOURCE:
- hval = Z_RES_HANDLE_P(offset);
- goto num_index_prop;
- case IS_REFERENCE:
- offset = Z_REFVAL_P(offset);
- goto isset_again;
- default:
- zend_error(E_WARNING, "Illegal offset type in isset or empty");
- value = NULL;
- break;
- }
- }
+ SAVE_OPLINE();
+ object_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- if (opline->extended_value & ZEND_ISSET) {
- /* > IS_NULL means not IS_UNDEF and not IS_NULL */
- result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
- }
- } else if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
- result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to check element of non-array");
- result = 0;
- }
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
- }
- } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
- zval tmp;
+ if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ }
+ ZVAL_DEREF(object_ptr);
+ if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
+ zend_free_op free_op2;
+ zval *property_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
- result = 0;
- if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
- if (IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) {
- ZVAL_DEREF(offset);
- }
- if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
- || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
- && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
- ZVAL_DUP(&tmp, offset);
- convert_to_long(&tmp);
- offset = &tmp;
- }
- }
- if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
- if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
- if ((opline->extended_value & ZEND_ISSET) ||
- Z_STRVAL_P(container)[offset->value.lval] != '0') {
- result = 1;
+ zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ } else {
+ zend_free_op free_op2, free_op_data1;
+ zval rv;
+ zval *value;
+ zval *dim = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ zval *variable_ptr;
+
+ if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
+ EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
+ zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+ zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
+ FREE_OP(free_op_data1);
+ } else {
+ zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_TMP_VAR TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+ ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+ variable_ptr = Z_INDIRECT(rv);
+ if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
+ FREE_OP(free_op_data1);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
+ value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
+ if ((opline+1)->op1_type == IS_VAR) {
+ FREE_OP(free_op_data1);
+ }
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), value);
}
}
}
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
- }
- } else {
- result = ((opline->extended_value & ZEND_ISSET) == 0);
}
- zval_ptr_dtor_nogc(free_op2);
- ZVAL_BOOL(EX_VAR(opline->result.var), result);
-
+ /* assign_dim has two opcodes! */
CHECK_EXCEPTION();
+ ZEND_VM_INC_OPCODE();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op2;
- zval *container;
- int result;
- zval *offset;
+ zval *value;
+ zval *variable_ptr;
SAVE_OPLINE();
- container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
- offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ value = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+ variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
- result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to check property of non-object");
- result = 0;
+ if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
+ if (IS_TMP_VAR == IS_TMP_VAR) {
+ zval_ptr_dtor_nogc(free_op2);
}
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
}
} else {
- result = ((opline->extended_value & ZEND_ISSET) == 0);
+ value = zend_assign_to_variable(variable_ptr, value, IS_TMP_VAR TSRMLS_CC);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), value);
+ }
+
}
- zval_ptr_dtor_nogc(free_op2);
- ZVAL_BOOL(EX_VAR(opline->result.var), result);
+ /* zend_assign_to_variable() always takes care of op2, never free it! */
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
FREE_OP(free_op_data1);
}
- /* assign_obj has two opcodes! */
+ /* assign_obj has two opcodes! */
+ CHECK_EXCEPTION();
+ ZEND_VM_INC_OPCODE();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_CV_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op2, free_op_data1;
+ zval *var_ptr, rv;
+ zval *value, *container;
+
+ SAVE_OPLINE();
+ container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ }
+ if (IS_CV != IS_UNUSED) {
+ ZVAL_DEREF(container);
+ }
+ if (IS_CV == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ if (IS_CV == IS_VAR && !0) {
+ Z_ADDREF_P(container); /* undo the effect of get_obj_zval_ptr_ptr() */
+ }
+ return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else {
+ zval *dim = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+
+ zend_fetch_dimension_address_RW(&rv, container, dim, IS_VAR TSRMLS_CC);
+ value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+ ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+ var_ptr = Z_INDIRECT(rv);
+ }
+
+ if (UNEXPECTED(var_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
+ }
+
+ if (UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
+
+ binary_op(var_ptr, var_ptr, value TSRMLS_CC);
+
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+ }
+ }
+
+ zval_ptr_dtor_nogc(free_op2);
+ FREE_OP(free_op_data1);
+
+ CHECK_EXCEPTION();
+ ZEND_VM_INC_OPCODE();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op2;
+ zval *var_ptr;
+ zval *value;
+
+ SAVE_OPLINE();
+ value = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+ var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+
+ if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
+ }
+
+ if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
+
+ binary_op(var_ptr, var_ptr, value TSRMLS_CC);
+
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+ }
+ }
+
+ zval_ptr_dtor_nogc(free_op2);
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
+
+static int ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
+
+static int ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
+
+static int ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
+
+static int ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
+
+static int ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
+
+static int ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
+
+static int ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
+
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
+
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
+
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
+
+static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CV_VAR(int type, ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ zval *varname;
+ zval *retval;
+ zend_string *name;
+ HashTable *target_symbol_table;
+
+ SAVE_OPLINE();
+ varname = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+
+ if (IS_CV == IS_CONST) {
+ name = Z_STR_P(varname);
+ } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
+ name = Z_STR_P(varname);
+ zend_string_addref(name);
+ } else {
+ name = zval_get_string(varname);
+ }
+
+ if (IS_VAR != IS_UNUSED) {
+ zend_class_entry *ce;
+
+ if (IS_VAR == IS_CONST) {
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ } else {
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+ if (UNEXPECTED(ce == NULL)) {
+ if (IS_CV != IS_CONST) {
+ zend_string_release(name);
+ }
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+ }
+ } else {
+ ce = Z_CE_P(EX_VAR(opline->op2.var));
+ }
+ retval = zend_std_get_static_property(ce, name, 0, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+
+ } else {
+ target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+ retval = zend_hash_find(target_symbol_table, name);
+ if (retval == NULL) {
+ switch (type) {
+ case BP_VAR_R:
+ case BP_VAR_UNSET:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_IS:
+ retval = &EG(uninitialized_zval);
+ break;
+ case BP_VAR_RW:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_W:
+ retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
+ break;
+ EMPTY_SWITCH_DEFAULT_CASE()
+ }
+ /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
+ } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
+ retval = Z_INDIRECT_P(retval);
+ if (Z_TYPE_P(retval) == IS_UNDEF) {
+ switch (type) {
+ case BP_VAR_R:
+ case BP_VAR_UNSET:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_IS:
+ retval = &EG(uninitialized_zval);
+ break;
+ case BP_VAR_RW:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_W:
+ ZVAL_NULL(retval);
+ break;
+ EMPTY_SWITCH_DEFAULT_CASE()
+ }
+ }
+ }
+ if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
+ if (Z_CONSTANT_P(retval)) {
+ zval_update_constant(retval, 1 TSRMLS_CC);
+ }
+ } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
+
+ }
+ }
+
+ if (IS_CV != IS_CONST) {
+ zend_string_release(name);
+ }
+
+ ZEND_ASSERT(retval != NULL);
+ if (type == BP_VAR_R || type == BP_VAR_IS) {
+ if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
+ ZVAL_UNREF(retval);
+ }
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ } else {
+ ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
+ }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_FETCH_R_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL ZEND_FETCH_W_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL ZEND_FETCH_RW_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL ZEND_FETCH_FUNC_ARG_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+ return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else {
+ return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
+
+static int ZEND_FASTCALL ZEND_FETCH_UNSET_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL ZEND_FETCH_IS_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op2;
+ zval *container;
+
+ SAVE_OPLINE();
+ container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+
CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_CV_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_W_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2, free_op_data1;
- zval *var_ptr, rv;
- zval *value, *container;
+ zend_free_op free_op1, free_op2;
+ zval *container;
SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+ container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+
if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
- if (IS_CV != IS_UNUSED) {
- ZVAL_DEREF(container);
- }
- if (IS_CV == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (IS_CV == IS_VAR && !0) {
- Z_ADDREF_P(container); /* undo the effect of get_obj_zval_ptr_ptr() */
- }
- return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else {
- zval *dim = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
-
- zend_fetch_dimension_address_RW(&rv, container, dim, IS_VAR TSRMLS_CC);
- value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
- var_ptr = Z_INDIRECT(rv);
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
- if (UNEXPECTED(var_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
- }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- if (UNEXPECTED(var_ptr == &EG(error_zval))) {
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- } else {
- ZVAL_DEREF(var_ptr);
- SEPARATE_ZVAL_NOREF(var_ptr);
+static int ZEND_FASTCALL ZEND_FETCH_DIM_RW_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1, free_op2;
+ zval *container;
- binary_op(var_ptr, var_ptr, value TSRMLS_CC);
+ SAVE_OPLINE();
+ container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
- }
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
-
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
zval_ptr_dtor_nogc(free_op2);
- FREE_OP(free_op_data1);
+ if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ }
CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_IS_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op2;
- zval *var_ptr;
- zval *value;
+ zval *container;
SAVE_OPLINE();
- value = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
- var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+ container = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
+ zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
- if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
- }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- } else {
- ZVAL_DEREF(var_ptr);
- SEPARATE_ZVAL_NOREF(var_ptr);
+static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zval *container;
+ zend_free_op free_op1, free_op2;
- binary_op(var_ptr, var_ptr, value TSRMLS_CC);
+ SAVE_OPLINE();
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+ if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+ if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
+ zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+ }
+ container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
- }
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+ if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ }
+ zval_ptr_dtor_nogc(free_op2);
- zval_ptr_dtor_nogc(free_op2);
+ } else {
+ if (IS_VAR == IS_UNUSED) {
+ zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
+ }
+ container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_UNSET_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zend_free_op free_op1, free_op2;
+ zval *container;
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ SAVE_OPLINE();
+ container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
+
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ }
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_DIM_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
+ zval *object_ptr;
-static int ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ SAVE_OPLINE();
+ object_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
-}
+ ZVAL_DEREF(object_ptr);
+ if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
+ zend_free_op free_op2;
+ zval *property_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-static int ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ } else {
+ zend_free_op free_op2, free_op_data1;
+ zval rv;
+ zval *value;
+ zval *dim = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+ zval *variable_ptr;
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
+ EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
+ zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+ zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
+ FREE_OP(free_op_data1);
+ } else {
+ zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_VAR TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
+ value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+ ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+ variable_ptr = Z_INDIRECT(rv);
+ if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
+ FREE_OP(free_op_data1);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
+ value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
+ if ((opline+1)->op1_type == IS_VAR) {
+ FREE_OP(free_op_data1);
+ }
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), value);
+ }
+ }
+ }
}
+
+ /* assign_dim has two opcodes! */
+ CHECK_EXCEPTION();
+ ZEND_VM_INC_OPCODE();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zend_free_op free_op2;
+ zval *value;
+ zval *variable_ptr;
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
+ SAVE_OPLINE();
+ value = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+ variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-static int ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
+ if (IS_VAR == IS_TMP_VAR) {
+ zval_ptr_dtor_nogc(free_op2);
+ }
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
+ value = zend_assign_to_variable(variable_ptr, value, IS_VAR TSRMLS_CC);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), value);
+ }
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-}
-static int ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ /* zend_assign_to_variable() always takes care of op2, never free it! */
+ zval_ptr_dtor_nogc(free_op2);
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_REF_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zend_free_op free_op2;
+ zval *variable_ptr;
+ zval *value_ptr;
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
+ SAVE_OPLINE();
+ value_ptr = _get_zval_ptr_ptr_var(opline->op2.var, execute_data, &free_op2);
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ if (IS_VAR == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
+ }
+ if (IS_VAR == IS_VAR &&
+ (value_ptr == &EG(uninitialized_zval) ||
+ (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+ !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+ if (!(free_op2 != NULL)) {
+ PZVAL_LOCK(value_ptr); /* undo the effect of get_zval_ptr_ptr() */
+ }
+ zend_error(E_STRICT, "Only variables should be assigned by reference");
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ if (free_op2) {zval_ptr_dtor_nogc(free_op2);};
+ HANDLE_EXCEPTION();
+ }
+ return ZEND_ASSIGN_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (IS_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
+ if (!(free_op2 != NULL)) {
+ PZVAL_LOCK(value_ptr);
+ }
+ }
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
+ }
+ if (IS_CV == IS_VAR &&
+ UNEXPECTED(Z_TYPE_P(EX_VAR(opline->op1.var)) != IS_INDIRECT) &&
+ UNEXPECTED(!Z_ISREF_P(variable_ptr))) {
+ zend_error_noreturn(E_ERROR, "Cannot assign by reference to overloaded object");
+ }
+ if ((IS_CV == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) ||
+ (IS_VAR == IS_VAR && UNEXPECTED(value_ptr == &EG(error_zval)))) {
+ variable_ptr = &EG(uninitialized_zval);
+ } else {
+ zend_assign_to_variable_reference(variable_ptr, value_ptr TSRMLS_CC);
}
-}
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ if (IS_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
+ if (!(free_op2 != NULL)) {
+ Z_DELREF_P(variable_ptr);
+ }
+ }
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), variable_ptr);
}
-}
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ if (free_op2) {zval_ptr_dtor_nogc(free_op2);};
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_VAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_UNSET_VAR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
- zval *object;
- zval *property;
- zval *retval;
- zval *zptr;
+ zval tmp, *varname;
+ HashTable *target_symbol_table;
- SAVE_OPLINE();
- object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- retval = EX_VAR(opline->result.var);
- if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
+ SAVE_OPLINE();
+ if (IS_CV == IS_CV &&
+ IS_VAR == IS_UNUSED &&
+ (opline->extended_value & ZEND_QUICK_SET)) {
+ zval *var = EX_VAR(opline->op1.var);
- if (IS_CV != IS_UNUSED) {
- object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
- }
+ if (Z_REFCOUNTED_P(var)) {
+ zend_refcounted *garbage = Z_COUNTED_P(var);
- if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- zval_ptr_dtor_nogc(free_op2);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(retval);
+ if (!--GC_REFCOUNT(garbage)) {
+ ZVAL_UNDEF(var);
+ _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
+ } else {
+ GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
+ ZVAL_UNDEF(var);
+ }
+ } else {
+ ZVAL_UNDEF(var);
}
-
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
- /* here we are sure we are dealing with an object */
-
- if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
-
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
+ varname = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- incdec_op(zptr);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(retval, zptr);
- }
- } else {
- zval rv;
+ ZVAL_UNDEF(&tmp);
+ if (IS_CV != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
+ ZVAL_STR(&tmp, zval_get_string(varname));
+ varname = &tmp;
+ }
- if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+ if (IS_VAR != IS_UNUSED) {
+ zend_class_entry *ce;
- if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
- zval rv;
- zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+ if (IS_VAR == IS_CONST) {
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ } else {
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ if (IS_CV != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+ zend_string_release(Z_STR(tmp));
+ }
- if (Z_REFCOUNT_P(z) == 0) {
- zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
+ HANDLE_EXCEPTION();
}
- ZVAL_COPY_VALUE(z, value);
+ if (UNEXPECTED(ce == NULL)) {
+ zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
+ }
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
}
- if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
- SEPARATE_ZVAL_IF_NOT_REF(z);
- incdec_op(z);
- ZVAL_COPY_VALUE(retval, z);
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
- SELECTIVE_PZVAL_LOCK(retval, opline);
- zval_ptr_dtor(z);
} else {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(retval);
- }
+ ce = Z_CE_P(EX_VAR(opline->op2.var));
}
+ zend_std_unset_static_property(ce, Z_STR_P(varname), ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+ } else {
+ target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+ zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
}
- zval_ptr_dtor_nogc(free_op2);
+ if (IS_CV != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+ zend_string_release(Z_STR(tmp));
+ }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_pre_incdec_property_helper_SPEC_CV_VAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_pre_incdec_property_helper_SPEC_CV_VAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_VAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_VAR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
- zval *object;
- zval *property;
- zval *retval;
- zval *zptr;
+ zval *value;
SAVE_OPLINE();
- object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- retval = EX_VAR(opline->result.var);
-
- if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
- }
-
- if (IS_CV != IS_UNUSED) {
- object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
- }
-
- if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- zval_ptr_dtor_nogc(free_op2);
- ZVAL_NULL(retval);
-
- CHECK_EXCEPTION();
+ if (IS_CV == IS_CV &&
+ IS_VAR == IS_UNUSED &&
+ (opline->extended_value & ZEND_QUICK_SET)) {
+ value = EX_VAR(opline->op1.var);
+ if (opline->extended_value & ZEND_ISSET) {
+ ZVAL_BOOL(EX_VAR(opline->result.var),
+ Z_TYPE_P(value) > IS_NULL &&
+ (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+ } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+ ZVAL_BOOL(EX_VAR(opline->result.var),
+ !i_zend_is_true(value TSRMLS_CC));
+ CHECK_EXCEPTION();
+ }
ZEND_VM_NEXT_OPCODE();
- }
-
- /* here we are sure we are dealing with an object */
-
- if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+ } else {
- ZVAL_DEREF(zptr);
- ZVAL_COPY_VALUE(retval, zptr);
- zval_opt_copy_ctor(zptr);
+ zval tmp, *varname = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
- incdec_op(zptr);
- } else {
- if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval rv;
- zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
- zval z_copy;
+ ZVAL_UNDEF(&tmp);
+ if (IS_CV != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
+ ZVAL_STR(&tmp, zval_get_string(varname));
+ varname = &tmp;
+ }
- if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
- zval rv;
- zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+ if (IS_VAR != IS_UNUSED) {
+ zend_class_entry *ce;
- if (Z_REFCOUNT_P(z) == 0) {
- zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
+ if (IS_VAR == IS_CONST) {
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ } else {
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+ if (UNEXPECTED(ce == NULL)) {
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
}
- ZVAL_COPY_VALUE(z, value);
+ } else {
+ ce = Z_CE_P(EX_VAR(opline->op2.var));
}
- ZVAL_DUP(retval, z);
- ZVAL_DUP(&z_copy, z);
- incdec_op(&z_copy);
- if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
- Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
- zval_ptr_dtor(&z_copy);
- zval_ptr_dtor(z);
+ value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
} else {
- zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- ZVAL_NULL(retval);
+ HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+ value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
}
- }
-
- zval_ptr_dtor_nogc(free_op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ if (IS_CV != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+ zend_string_release(Z_STR(tmp));
+ }
-static int ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_post_incdec_property_helper_SPEC_CV_VAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ if (opline->extended_value & ZEND_ISSET) {
+ ZVAL_BOOL(EX_VAR(opline->result.var),
+ value && Z_TYPE_P(value) > IS_NULL &&
+ (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+ } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+ ZVAL_BOOL(EX_VAR(opline->result.var),
+ !value || !i_zend_is_true(value TSRMLS_CC));
+ }
-static int ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_post_incdec_property_helper_SPEC_CV_VAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
}
-static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CV_VAR(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INSTANCEOF_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *varname;
- zval *retval;
- zend_string *name;
- HashTable *target_symbol_table;
+ zval *expr;
+ zend_bool result;
SAVE_OPLINE();
- varname = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-
- if (IS_CV == IS_CONST) {
- name = Z_STR_P(varname);
- } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
- name = Z_STR_P(varname);
- zend_string_addref(name);
- } else {
- name = zval_get_string(varname);
- }
+ expr = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_VAR != IS_UNUSED) {
+ if (Z_TYPE_P(expr) == IS_OBJECT) {
zend_class_entry *ce;
if (IS_VAR == IS_CONST) {
if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
} else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, ZEND_FETCH_CLASS_NO_AUTOLOAD TSRMLS_CC);
if (UNEXPECTED(ce == NULL)) {
- if (IS_CV != IS_CONST) {
- zend_string_release(name);
- }
+ ZVAL_FALSE(EX_VAR(opline->result.var));
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
} else {
ce = Z_CE_P(EX_VAR(opline->op2.var));
}
- retval = zend_std_get_static_property(ce, name, 0, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
-
+ result = instanceof_function(Z_OBJCE_P(expr), ce TSRMLS_CC);
} else {
- target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- retval = zend_hash_find(target_symbol_table, name);
- if (retval == NULL) {
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_UNSET:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_IS:
- retval = &EG(uninitialized_zval);
- break;
- case BP_VAR_RW:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_W:
- retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
- }
- /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
- } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
- retval = Z_INDIRECT_P(retval);
- if (Z_TYPE_P(retval) == IS_UNDEF) {
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_UNSET:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_IS:
- retval = &EG(uninitialized_zval);
- break;
- case BP_VAR_RW:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_W:
- ZVAL_NULL(retval);
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
- }
- }
- }
- if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
- if (Z_CONSTANT_P(retval)) {
- zval_update_constant(retval, 1 TSRMLS_CC);
- }
- } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
-
- }
- }
-
- if (IS_CV != IS_CONST) {
- zend_string_release(name);
+ result = 0;
}
+ ZVAL_BOOL(EX_VAR(opline->result.var), result);
- ZEND_ASSERT(retval != NULL);
- if (type == BP_VAR_R || type == BP_VAR_IS) {
- if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
- ZVAL_UNREF(retval);
- }
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- } else {
- ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
- }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_R_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_YIELD_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ USE_OPLINE
-static int ZEND_FASTCALL ZEND_FETCH_W_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ /* The generator object is stored in EX(return_value) */
+ zend_generator *generator = (zend_generator *) EX(return_value);
-static int ZEND_FASTCALL ZEND_FETCH_RW_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
+ zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
+ }
-static int ZEND_FASTCALL ZEND_FETCH_FUNC_ARG_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ /* Destroy the previously yielded value */
+ zval_ptr_dtor(&generator->value);
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else {
- return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
+ /* Destroy the previously yielded key */
+ zval_ptr_dtor(&generator->key);
-static int ZEND_FASTCALL ZEND_FETCH_UNSET_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ /* Set the new yielded value */
+ if (IS_CV != IS_UNUSED) {
-static int ZEND_FASTCALL ZEND_FETCH_IS_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
- zval *container;
+ if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
+ /* Constants and temporary variables aren't yieldable by reference,
+ * but we still allow them with a notice. */
+ if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
+ zval *value;
- SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ zend_error(E_NOTICE, "Only variable references should be yielded by reference");
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ ZVAL_COPY_VALUE(&generator->value, value);
+ if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
-static int ZEND_FASTCALL ZEND_FETCH_DIM_W_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *container;
+ /* Temporary variables don't need ctor copying */
+ if (IS_CV != IS_TMP_VAR) {
+ zval_opt_copy_ctor(&generator->value);
+ }
+ } else {
+ zval *value_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ if (IS_CV == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
+ }
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
+ /* If a function call result is yielded and the function did
+ * not return by reference we throw a notice. */
+ if (IS_CV == IS_VAR &&
+ (value_ptr == &EG(uninitialized_zval) ||
+ (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+ !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+ zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+ } else {
+ ZVAL_MAKE_REF(value_ptr);
+ }
+ ZVAL_COPY(&generator->value, value_ptr);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ }
+ } else {
+ zval *value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-static int ZEND_FASTCALL ZEND_FETCH_DIM_RW_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *container;
+ /* Consts, temporary variables and references need copying */
+ if (IS_CV == IS_CONST) {
+ ZVAL_DUP(&generator->value, value);
+ } else if (IS_CV == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&generator->value, value);
+ } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(value)) {
+ ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
- SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+ } else {
+ ZVAL_COPY_VALUE(&generator->value, value);
+ if (IS_CV == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+ }
+ }
+ }
+ } else {
+ /* If no value was specified yield null */
+ ZVAL_NULL(&generator->value);
+ }
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ /* Set the new yielded key */
+ if (IS_VAR != IS_UNUSED) {
+ zend_free_op free_op2;
+ zval *key = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+
+ /* Consts, temporary variables and references need copying */
+ if (IS_VAR == IS_CONST) {
+ ZVAL_DUP(&generator->key, key);
+ } else if (IS_VAR == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&generator->key, key);
+ } else if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && Z_ISREF_P(key)) {
+ ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
+ zval_ptr_dtor_nogc(free_op2);
+ } else {
+ ZVAL_COPY_VALUE(&generator->key, key);
+ if (IS_VAR == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
+ }
+ }
+
+ if (Z_TYPE(generator->key) == IS_LONG
+ && Z_LVAL(generator->key) > generator->largest_used_integer_key
+ ) {
+ generator->largest_used_integer_key = Z_LVAL(generator->key);
+ }
+ } else {
+ /* If no key was specified we use auto-increment keys */
+ generator->largest_used_integer_key++;
+ ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
}
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+
+ if (RETURN_VALUE_USED(opline)) {
+ /* If the return value of yield is used set the send
+ * target and initialize it to NULL */
+ generator->send_target = EX_VAR(opline->result.var);
+ ZVAL_NULL(generator->send_target);
+ } else {
+ generator->send_target = NULL;
}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ /* We increment to the next op, so we are at the correct position when the
+ * generator is resumed. */
+ ZEND_VM_INC_OPCODE();
+
+ /* The GOTO VM uses a local opline variable. We need to set the opline
+ * variable in execute_data so we don't resume at an old position. */
+ SAVE_OPLINE();
+
+ ZEND_VM_RETURN();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_IS_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_POW_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op2;
- zval *container;
SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
- zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ pow_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_binary_assign_op_helper_SPEC_CV_VAR(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *container;
- zend_free_op free_op1, free_op2;
+ zend_free_op free_op_data1;
+ zval *object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+ zval *property = NULL;
+ zval *value;
+ zval *zptr;
- SAVE_OPLINE();
+ if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+ }
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
- zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
- }
- container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
- zval_ptr_dtor_nogc(free_op2);
+ if (IS_CV != IS_UNUSED) {
+ object = make_real_object(object TSRMLS_CC);
+ }
+
+ value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+
+ if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ zend_error(E_WARNING, "Attempt to assign property of non-object");
+ FREE_OP(free_op_data1);
+
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
} else {
- if (IS_VAR == IS_UNUSED) {
- zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
+ /* here we are sure we are dealing with an object */
+ if (opline->extended_value == ZEND_ASSIGN_OBJ
+ && EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_UNUSED == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+
+ ZVAL_DEREF(zptr);
+ SEPARATE_ZVAL_NOREF(zptr);
+
+ binary_op(zptr, zptr, value TSRMLS_CC);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), zptr);
+ }
+ } else {
+ zval *z = NULL;
+ zval rv;
+
+ if (opline->extended_value == ZEND_ASSIGN_OBJ) {
+ if (Z_OBJ_HT_P(object)->read_property) {
+ z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_UNUSED == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+ }
+ } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
+ if (Z_OBJ_HT_P(object)->read_dimension) {
+ z = Z_OBJ_HT_P(object)->read_dimension(object, property, BP_VAR_R, &rv TSRMLS_CC);
+ }
+ }
+ if (z) {
+ if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+ zval rv;
+ zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+
+ if (Z_REFCOUNT_P(z) == 0) {
+ zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
+ }
+ ZVAL_COPY_VALUE(z, value);
+ }
+//??? if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
+ SEPARATE_ZVAL_IF_NOT_REF(z);
+ binary_op(z, z, value TSRMLS_CC);
+ if (opline->extended_value == ZEND_ASSIGN_OBJ) {
+ Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_UNUSED == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+ } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
+ Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
+ }
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), z);
+ }
+ zval_ptr_dtor(z);
+ } else {
+ zend_error(E_WARNING, "Attempt to assign property of non-object");
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ }
}
- container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ FREE_OP(free_op_data1);
}
+
+ /* assign_obj has two opcodes! */
CHECK_EXCEPTION();
+ ZEND_VM_INC_OPCODE();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_UNSET_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *container;
+ zend_free_op free_op_data1;
+ zval *var_ptr, rv;
+ zval *value, *container;
SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
-
+ container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ if (IS_CV != IS_UNUSED) {
+ ZVAL_DEREF(container);
+ }
+ if (IS_CV == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ if (IS_CV == IS_VAR && !0) {
+ Z_ADDREF_P(container); /* undo the effect of get_obj_zval_ptr_ptr() */
+ }
+ return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else {
+ zval *dim = NULL;
+
+ zend_fetch_dimension_address_RW(&rv, container, dim, IS_UNUSED TSRMLS_CC);
+ value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+ ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+ var_ptr = Z_INDIRECT(rv);
+ }
+
+ if (UNEXPECTED(var_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
+ }
+
+ if (UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
+
+ binary_op(var_ptr, var_ptr, value TSRMLS_CC);
+
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+ }
}
+ FREE_OP(free_op_data1);
+
CHECK_EXCEPTION();
+ ZEND_VM_INC_OPCODE();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_UNUSED(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *container;
- zend_free_op free_op2;
- zval *offset;
+ zval *var_ptr;
+ zval *value;
SAVE_OPLINE();
- container = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
- if ((IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
- UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
- zend_error(E_NOTICE, "Trying to get property of non-object");
- ZVAL_NULL(EX_VAR(opline->result.var));
- } else {
- zval *retval;
+ value = NULL;
+ var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- /* here we are sure we are dealing with an object */
- do {
- if (IS_VAR == IS_CONST &&
- EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
- zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
- zend_object *zobj = Z_OBJ_P(container);
+ if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
+ }
- if (EXPECTED(prop_info)) {
- retval = OBJ_PROP(zobj, prop_info->offset);
- if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- } else if (EXPECTED(zobj->properties != NULL)) {
- retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
- if (EXPECTED(retval)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- }
- }
+ if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
+ ZVAL_DEREF(var_ptr);
+ SEPARATE_ZVAL_NOREF(var_ptr);
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+ binary_op(var_ptr, var_ptr, value TSRMLS_CC);
- if (retval != EX_VAR(opline->result.var)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- }
- } while (0);
+ if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+ ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+ }
}
- zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_W_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *property;
- zval *container;
-
- SAVE_OPLINE();
- property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
- container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_UNUSED(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_RW_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *property;
- zval *container;
-
- SAVE_OPLINE();
- property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_UNUSED(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *container;
- zend_free_op free_op2;
- zval *offset;
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_UNUSED(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
- SAVE_OPLINE();
- container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+static int ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- if ((IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
- UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- } else {
- zval *retval;
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_UNUSED(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
- /* here we are sure we are dealing with an object */
- do {
- if (IS_VAR == IS_CONST &&
- EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
- zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
- zend_object *zobj = Z_OBJ_P(container);
+static int ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- if (EXPECTED(prop_info)) {
- retval = OBJ_PROP(zobj, prop_info->offset);
- if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- } else if (EXPECTED(zobj->properties != NULL)) {
- retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
- if (EXPECTED(retval)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- break;
- }
- }
- }
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_UNUSED(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+static int ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- if (retval != EX_VAR(opline->result.var)) {
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- }
- } while (0);
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_UNUSED(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
+}
- zval_ptr_dtor_nogc(free_op2);
+static int ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_UNUSED(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *container;
-
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- /* Behave like FETCH_OBJ_W */
- zend_free_op free_op1, free_op2;
- zval *property;
- SAVE_OPLINE();
- property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_UNUSED(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
- if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
- zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
- }
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- } else {
- return ZEND_FETCH_OBJ_R_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_UNUSED(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_UNSET_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1, free_op2;
- zval *container, *property;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
- property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_UNUSED(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
- zval *object;
- zval *property_name;
-
- SAVE_OPLINE();
- object = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- property_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_UNUSED(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
- zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
-
- /* assign_obj has two opcodes! */
- CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_DIM_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CV_UNUSED(int type, ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *object_ptr;
+ zval *varname;
+ zval *retval;
+ zend_string *name;
+ HashTable *target_symbol_table;
SAVE_OPLINE();
- object_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ varname = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ if (IS_CV == IS_CONST) {
+ name = Z_STR_P(varname);
+ } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
+ name = Z_STR_P(varname);
+ zend_string_addref(name);
+ } else {
+ name = zval_get_string(varname);
}
- ZVAL_DEREF(object_ptr);
- if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
- zend_free_op free_op2;
- zval *property_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- } else {
- zend_free_op free_op2, free_op_data1;
- zval rv;
- zval *value;
- zval *dim = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
- zval *variable_ptr;
+ if (IS_UNUSED != IS_UNUSED) {
+ zend_class_entry *ce;
- if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
- EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
- zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
- FREE_OP(free_op_data1);
- } else {
- zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_VAR TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
- variable_ptr = Z_INDIRECT(rv);
- if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
- FREE_OP(free_op_data1);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
+ if (IS_UNUSED == IS_CONST) {
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
} else {
- value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
- if ((opline+1)->op1_type == IS_VAR) {
- FREE_OP(free_op_data1);
- }
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), value);
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+ if (UNEXPECTED(ce == NULL)) {
+ if (IS_CV != IS_CONST) {
+ zend_string_release(name);
+ }
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
}
+ } else {
+ ce = Z_CE_P(EX_VAR(opline->op2.var));
}
- }
-
- /* assign_dim has two opcodes! */
- CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
- zval *value;
- zval *variable_ptr;
-
- SAVE_OPLINE();
- value = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
- variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ retval = zend_std_get_static_property(ce, name, 0, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
- if (IS_VAR == IS_TMP_VAR) {
- zval_ptr_dtor_nogc(free_op2);
- }
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
} else {
- value = zend_assign_to_variable(variable_ptr, value, IS_VAR TSRMLS_CC);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), value);
+ target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+ retval = zend_hash_find(target_symbol_table, name);
+ if (retval == NULL) {
+ switch (type) {
+ case BP_VAR_R:
+ case BP_VAR_UNSET:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_IS:
+ retval = &EG(uninitialized_zval);
+ break;
+ case BP_VAR_RW:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_W:
+ retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
+ break;
+ EMPTY_SWITCH_DEFAULT_CASE()
+ }
+ /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
+ } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
+ retval = Z_INDIRECT_P(retval);
+ if (Z_TYPE_P(retval) == IS_UNDEF) {
+ switch (type) {
+ case BP_VAR_R:
+ case BP_VAR_UNSET:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_IS:
+ retval = &EG(uninitialized_zval);
+ break;
+ case BP_VAR_RW:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_W:
+ ZVAL_NULL(retval);
+ break;
+ EMPTY_SWITCH_DEFAULT_CASE()
+ }
+ }
}
+ if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
+ if (Z_CONSTANT_P(retval)) {
+ zval_update_constant(retval, 1 TSRMLS_CC);
+ }
+ } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
+ }
}
- /* zend_assign_to_variable() always takes care of op2, never free it! */
- zval_ptr_dtor_nogc(free_op2);
+ if (IS_CV != IS_CONST) {
+ zend_string_release(name);
+ }
+ ZEND_ASSERT(retval != NULL);
+ if (type == BP_VAR_R || type == BP_VAR_IS) {
+ if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
+ ZVAL_UNREF(retval);
+ }
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ } else {
+ ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
+ }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_REF_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_R_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- USE_OPLINE
- zend_free_op free_op2;
- zval *variable_ptr;
- zval *value_ptr;
+ return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
- SAVE_OPLINE();
- value_ptr = _get_zval_ptr_ptr_var(opline->op2.var, execute_data, &free_op2);
+static int ZEND_FASTCALL ZEND_FETCH_W_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
- if (IS_VAR == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
- }
- if (IS_VAR == IS_VAR &&
- (value_ptr == &EG(uninitialized_zval) ||
- (opline->extended_value == ZEND_RETURNS_FUNCTION &&
- !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
- if (!(free_op2 != NULL)) {
- PZVAL_LOCK(value_ptr); /* undo the effect of get_zval_ptr_ptr() */
- }
- zend_error(E_STRICT, "Only variables should be assigned by reference");
- if (UNEXPECTED(EG(exception) != NULL)) {
- if (free_op2) {zval_ptr_dtor_nogc(free_op2);};
- HANDLE_EXCEPTION();
- }
- return ZEND_ASSIGN_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (IS_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
- if (!(free_op2 != NULL)) {
- PZVAL_LOCK(value_ptr);
- }
- }
+static int ZEND_FASTCALL ZEND_FETCH_RW_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
- variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
- }
- if (IS_CV == IS_VAR &&
- UNEXPECTED(Z_TYPE_P(EX_VAR(opline->op1.var)) != IS_INDIRECT) &&
- UNEXPECTED(!Z_ISREF_P(variable_ptr))) {
- zend_error_noreturn(E_ERROR, "Cannot assign by reference to overloaded object");
- }
- if ((IS_CV == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) ||
- (IS_VAR == IS_VAR && UNEXPECTED(value_ptr == &EG(error_zval)))) {
- variable_ptr = &EG(uninitialized_zval);
+static int ZEND_FASTCALL ZEND_FETCH_FUNC_ARG_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+ return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else {
- zend_assign_to_variable_reference(variable_ptr, value_ptr TSRMLS_CC);
+ return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
+}
+
+static int ZEND_FASTCALL ZEND_FETCH_UNSET_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL ZEND_FETCH_IS_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
- if (IS_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
- if (!(free_op2 != NULL)) {
- Z_DELREF_P(variable_ptr);
- }
- }
+static int ZEND_FASTCALL ZEND_FETCH_DIM_W_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+ zval *container;
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), variable_ptr);
+ SAVE_OPLINE();
+ container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
- if (free_op2) {zval_ptr_dtor_nogc(free_op2);};
+ if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_RW_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *function_name;
- zend_free_op free_op2;
- zval *object;
- zend_function *fbc;
- zend_class_entry *called_scope;
- zend_object *obj;
+ zend_free_op free_op1;
+ zval *container;
SAVE_OPLINE();
+ container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- function_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
- if (IS_VAR != IS_CONST &&
- UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
- if (UNEXPECTED(EG(exception) != NULL)) {
- HANDLE_EXCEPTION();
- }
- zend_error_noreturn(E_ERROR, "Method name must be a string");
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
- object = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ }
- if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- uint32_t nesting = 1;
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- if (UNEXPECTED(EG(exception) != NULL)) {
- zval_ptr_dtor_nogc(free_op2);
- HANDLE_EXCEPTION();
- }
+static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zval *container;
+ zend_free_op free_op1;
- zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s", Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
- zval_ptr_dtor_nogc(free_op2);
+ SAVE_OPLINE();
- if (EG(exception) != NULL) {
- HANDLE_EXCEPTION();
+ if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+ if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
+ zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+ }
+ container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ }
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
+ if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
- /* No exception raised: Skip over arguments until fcall opcode with correct
- * nesting level. Return NULL (except when return value unused) */
- do {
- opline++;
- if (opline->opcode == ZEND_INIT_FCALL ||
- opline->opcode == ZEND_INIT_FCALL_BY_NAME ||
- opline->opcode == ZEND_INIT_NS_FCALL_BY_NAME ||
- opline->opcode == ZEND_INIT_METHOD_CALL ||
- opline->opcode == ZEND_INIT_STATIC_METHOD_CALL ||
- opline->opcode == ZEND_INIT_USER_CALL ||
- opline->opcode == ZEND_NEW
- ) {
- nesting++;
- } else if (opline->opcode == ZEND_DO_FCALL) {
- nesting--;
- }
- } while (nesting);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
+ } else {
+ if (IS_UNUSED == IS_UNUSED) {
+ zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
}
+ container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
+
- /* We've skipped EXT_FCALL_BEGIND, so also skip the ending opcode */
- if ((opline + 1)->opcode == ZEND_EXT_FCALL_END) {
- opline++;
- }
- ZEND_VM_JMP(++opline);
}
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- obj = Z_OBJ_P(object);
- called_scope = obj->ce;
+static int ZEND_FASTCALL ZEND_ASSIGN_DIM_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- if (IS_VAR != IS_CONST ||
- EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
- zend_object *orig_obj = obj;
+ zval *object_ptr;
- if (UNEXPECTED(obj->handlers->get_method == NULL)) {
- zend_error_noreturn(E_ERROR, "Object does not support method calls");
- }
+ SAVE_OPLINE();
+ object_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- /* First, locate the function. */
- fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_VAR == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
- if (UNEXPECTED(fbc == NULL)) {
- zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
- }
- if (IS_VAR == IS_CONST &&
- EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
- EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
- EXPECTED(obj == orig_obj)) {
- CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope, fbc);
- }
+ if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
+ ZVAL_DEREF(object_ptr);
+ if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
- if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_STATIC) != 0)) {
- obj = NULL;
- } else {
- GC_REFCOUNT(obj)++; /* For $this pointer */
- }
+ zval *property_name = NULL;
- EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
- fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
+ zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_UNUSED == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
+ } else {
+ zend_free_op free_op_data1;
+ zval rv;
+ zval *value;
+ zval *dim = NULL;
+ zval *variable_ptr;
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
+ EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
+ zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
-static int ZEND_FASTCALL ZEND_CASE_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
- zval *result = EX_VAR(opline->result.var);
+ value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+ zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
+ FREE_OP(free_op_data1);
+ } else {
+ zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_UNUSED TSRMLS_CC);
- SAVE_OPLINE();
- fast_equal_function(result,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+ ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+ variable_ptr = Z_INDIRECT(rv);
+ if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
+ FREE_OP(free_op_data1);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
+ value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
+ if ((opline+1)->op1_type == IS_VAR) {
+ FREE_OP(free_op_data1);
+ }
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), value);
+ }
+ }
+ }
+ }
- zval_ptr_dtor_nogc(free_op2);
+ /* assign_dim has two opcodes! */
CHECK_EXCEPTION();
+ ZEND_VM_INC_OPCODE();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
}
}
- if (IS_VAR != IS_UNUSED) {
- zend_free_op free_op2;
- zval *offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ if (IS_UNUSED != IS_UNUSED) {
+
+ zval *offset = NULL;
zend_string *str;
zend_ulong hval;
break;
case IS_STRING:
str = Z_STR_P(offset);
- if (IS_VAR != IS_CONST) {
+ if (IS_UNUSED != IS_CONST) {
if (ZEND_HANDLE_NUMERIC(str, hval)) {
goto num_index;
}
/* do nothing */
break;
}
- zval_ptr_dtor_nogc(free_op2);
+
} else {
zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
zval *array;
uint32_t size;
ZEND_VM_NEXT_OPCODE();
#if 0 || IS_CV != IS_UNUSED
} else {
- return ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
#endif
}
}
-static int ZEND_FASTCALL ZEND_UNSET_VAR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_UNSET_VAR_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval tmp, *varname;
SAVE_OPLINE();
if (IS_CV == IS_CV &&
- IS_VAR == IS_UNUSED &&
+ IS_UNUSED == IS_UNUSED &&
(opline->extended_value & ZEND_QUICK_SET)) {
zval *var = EX_VAR(opline->op1.var);
varname = &tmp;
}
- if (IS_VAR != IS_UNUSED) {
+ if (IS_UNUSED != IS_UNUSED) {
zend_class_entry *ce;
- if (IS_VAR == IS_CONST) {
+ if (IS_UNUSED == IS_CONST) {
if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
} else {
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_UNSET_DIM_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
- zval *container;
- zval *offset;
- zend_ulong hval;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
- }
- if (IS_CV != IS_UNUSED) {
- ZVAL_DEREF(container);
- }
- SEPARATE_ZVAL_NOREF(container);
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
- if (IS_CV != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
- HashTable *ht = Z_ARRVAL_P(container);
-offset_again:
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- zend_hash_index_del(ht, hval);
- break;
- case IS_LONG:
- hval = Z_LVAL_P(offset);
-num_index_dim:
- zend_hash_index_del(ht, hval);
- break;
- case IS_STRING:
- if (IS_VAR != IS_CONST) {
- if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
- goto num_index_dim;
- }
- }
- if (ht == &EG(symbol_table).ht) {
- zend_delete_global_variable(Z_STR_P(offset) TSRMLS_CC);
- } else {
- zend_hash_del(ht, Z_STR_P(offset));
- }
- break;
- case IS_NULL:
- zend_hash_del(ht, STR_EMPTY_ALLOC());
- break;
- case IS_FALSE:
- hval = 0;
- goto num_index_dim;
- case IS_TRUE:
- hval = 1;
- goto num_index_dim;
- case IS_RESOURCE:
- hval = Z_RES_HANDLE_P(offset);
- goto num_index_dim;
- case IS_REFERENCE:
- offset = Z_REFVAL_P(offset);
- goto offset_again;
- break;
- default:
- zend_error(E_WARNING, "Illegal offset type in unset");
- break;
- }
- zval_ptr_dtor_nogc(free_op2);
- } else if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use object as array");
- }
-//??? if (IS_VAR == IS_CONST) {
-//??? zval_copy_ctor(offset);
-//??? }
- Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
- ZEND_VM_CONTINUE(); /* bailed out before */
- } else {
- zval_ptr_dtor_nogc(free_op2);
- }
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_UNSET_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
- zval *container;
- zval *offset;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
- }
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
- if (IS_CV != IS_UNUSED) {
- ZVAL_DEREF(container);
- }
- if (IS_CV == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
- if (Z_OBJ_HT_P(container)->unset_property) {
- Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to unset property of non-object");
- }
- }
- zval_ptr_dtor_nogc(free_op2);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_VAR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_VAR_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *value;
SAVE_OPLINE();
if (IS_CV == IS_CV &&
- IS_VAR == IS_UNUSED &&
+ IS_UNUSED == IS_UNUSED &&
(opline->extended_value & ZEND_QUICK_SET)) {
value = EX_VAR(opline->op1.var);
if (opline->extended_value & ZEND_ISSET) {
varname = &tmp;
}
- if (IS_VAR != IS_UNUSED) {
+ if (IS_UNUSED != IS_UNUSED) {
zend_class_entry *ce;
- if (IS_VAR == IS_CONST) {
+ if (IS_UNUSED == IS_CONST) {
if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
} else {
}
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
- zval *container;
- int result;
- zend_ulong hval;
- zval *offset;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
- if (IS_CV != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
- HashTable *ht = Z_ARRVAL_P(container);
- zval *value;
- zend_string *str;
-
-isset_again:
- if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
- str = Z_STR_P(offset);
- if (IS_VAR != IS_CONST) {
- if (ZEND_HANDLE_NUMERIC(str, hval)) {
- goto num_index_prop;
- }
- }
-str_index_prop:
- value = zend_hash_find_ind(ht, str);
- } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
- hval = Z_LVAL_P(offset);
-num_index_prop:
- value = zend_hash_index_find(ht, hval);
- } else {
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- goto num_index_prop;
- case IS_NULL:
- str = STR_EMPTY_ALLOC();
- goto str_index_prop;
- case IS_FALSE:
- hval = 0;
- goto num_index_prop;
- case IS_TRUE:
- hval = 1;
- goto num_index_prop;
- case IS_RESOURCE:
- hval = Z_RES_HANDLE_P(offset);
- goto num_index_prop;
- case IS_REFERENCE:
- offset = Z_REFVAL_P(offset);
- goto isset_again;
- default:
- zend_error(E_WARNING, "Illegal offset type in isset or empty");
- value = NULL;
- break;
- }
- }
-
- if (opline->extended_value & ZEND_ISSET) {
- /* > IS_NULL means not IS_UNDEF and not IS_NULL */
- result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
- }
- } else if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
- result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to check element of non-array");
- result = 0;
- }
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
- }
- } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
- zval tmp;
-
- result = 0;
- if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
- if (IS_VAR == IS_CV || IS_VAR == IS_VAR) {
- ZVAL_DEREF(offset);
- }
- if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
- || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
- && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
- ZVAL_DUP(&tmp, offset);
- convert_to_long(&tmp);
- offset = &tmp;
- }
- }
- if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
- if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
- if ((opline->extended_value & ZEND_ISSET) ||
- Z_STRVAL_P(container)[offset->value.lval] != '0') {
- result = 1;
- }
- }
- }
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
- }
- } else {
- result = ((opline->extended_value & ZEND_ISSET) == 0);
- }
-
- zval_ptr_dtor_nogc(free_op2);
- ZVAL_BOOL(EX_VAR(opline->result.var), result);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
- zval *container;
- int result;
- zval *offset;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
- offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
- if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
- result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to check property of non-object");
- result = 0;
- }
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
- }
- } else {
- result = ((opline->extended_value & ZEND_ISSET) == 0);
- }
-
- zval_ptr_dtor_nogc(free_op2);
- ZVAL_BOOL(EX_VAR(opline->result.var), result);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_INSTANCEOF_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- zval *expr;
- zend_bool result;
-
- SAVE_OPLINE();
- expr = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-
- if (Z_TYPE_P(expr) == IS_OBJECT) {
- zend_class_entry *ce;
-
- if (IS_VAR == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, ZEND_FETCH_CLASS_NO_AUTOLOAD TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- ZVAL_FALSE(EX_VAR(opline->result.var));
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
- }
- result = instanceof_function(Z_OBJCE_P(expr), ce TSRMLS_CC);
- } else {
- result = 0;
- }
- ZVAL_BOOL(EX_VAR(opline->result.var), result);
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_YIELD_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_YIELD_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
}
/* Set the new yielded key */
- if (IS_VAR != IS_UNUSED) {
- zend_free_op free_op2;
- zval *key = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+ if (IS_UNUSED != IS_UNUSED) {
+
+ zval *key = NULL;
/* Consts, temporary variables and references need copying */
- if (IS_VAR == IS_CONST) {
+ if (IS_UNUSED == IS_CONST) {
ZVAL_DUP(&generator->key, key);
- } else if (IS_VAR == IS_TMP_VAR) {
+ } else if (IS_UNUSED == IS_TMP_VAR) {
ZVAL_COPY_VALUE(&generator->key, key);
- } else if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && Z_ISREF_P(key)) {
+ } else if ((IS_UNUSED == IS_VAR || IS_UNUSED == IS_CV) && Z_ISREF_P(key)) {
ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
- zval_ptr_dtor_nogc(free_op2);
+
} else {
ZVAL_COPY_VALUE(&generator->key, key);
- if (IS_VAR == IS_CV) {
+ if (IS_UNUSED == IS_CV) {
if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
}
}
ZEND_VM_RETURN();
}
-static int ZEND_FASTCALL ZEND_POW_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_binary_assign_op_helper_SPEC_CV_UNUSED(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL ZEND_ADD_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
+
SAVE_OPLINE();
- pow_function(EX_VAR(opline->result.var),
+ fast_add_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_SUB_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+
+ SAVE_OPLINE();
+ fast_sub_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_MUL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+
+ SAVE_OPLINE();
+ fast_mul_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_DIV_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+
+ SAVE_OPLINE();
+ fast_div_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_MOD_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+
+ SAVE_OPLINE();
+ fast_mod_function(EX_VAR(opline->result.var),
_get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
- zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_binary_assign_op_helper_SPEC_CV_VAR(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ USE_OPLINE
+
+
+ SAVE_OPLINE();
+ shift_left_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+
+ SAVE_OPLINE();
+ shift_right_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_CONCAT_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+
+ SAVE_OPLINE();
+ concat_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_IS_IDENTICAL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+
+ SAVE_OPLINE();
+ fast_is_identical_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_IS_NOT_IDENTICAL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ zval *result = EX_VAR(opline->result.var);
+
+ SAVE_OPLINE();
+ fast_is_not_identical_function(result,
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_IS_EQUAL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ zval *result = EX_VAR(opline->result.var);
+
+ SAVE_OPLINE();
+ fast_equal_function(result,
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_IS_NOT_EQUAL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ zval *result = EX_VAR(opline->result.var);
+
+ SAVE_OPLINE();
+ fast_not_equal_function(result,
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_IS_SMALLER_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ zval *result = EX_VAR(opline->result.var);
+
+ SAVE_OPLINE();
+ fast_is_smaller_function(result,
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_IS_SMALLER_OR_EQUAL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ zval *result = EX_VAR(opline->result.var);
+
+ SAVE_OPLINE();
+ fast_is_smaller_or_equal_function(result,
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_BW_OR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+
+ SAVE_OPLINE();
+ bitwise_or_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_BW_AND_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+
+ SAVE_OPLINE();
+ bitwise_and_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_BW_XOR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+
+ SAVE_OPLINE();
+ bitwise_xor_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_BOOL_XOR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+
+ SAVE_OPLINE();
+ boolean_xor_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_CV(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op_data1;
zval *object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- zval *property = NULL;
+ zval *property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
zval *value;
zval *zptr;
/* here we are sure we are dealing with an object */
if (opline->extended_value == ZEND_ASSIGN_OBJ
&& EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_UNUSED == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
ZVAL_DEREF(zptr);
SEPARATE_ZVAL_NOREF(zptr);
if (opline->extended_value == ZEND_ASSIGN_OBJ) {
if (Z_OBJ_HT_P(object)->read_property) {
- z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_UNUSED == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+ z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
}
} else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
if (Z_OBJ_HT_P(object)->read_dimension) {
SEPARATE_ZVAL_IF_NOT_REF(z);
binary_op(z, z, value TSRMLS_CC);
if (opline->extended_value == ZEND_ASSIGN_OBJ) {
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_UNUSED == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+ Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
} else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_CV_CV(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op_data1;
if (IS_CV == IS_VAR && !0) {
Z_ADDREF_P(container); /* undo the effect of get_obj_zval_ptr_ptr() */
}
- return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_CV_CV(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else {
- zval *dim = NULL;
+ zval *dim = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
- zend_fetch_dimension_address_RW(&rv, container, dim, IS_UNUSED TSRMLS_CC);
+ zend_fetch_dimension_address_RW(&rv, container, dim, IS_CV TSRMLS_CC);
value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
var_ptr = Z_INDIRECT(rv);
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_UNUSED(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_CV(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *value;
SAVE_OPLINE();
- value = NULL;
+ value = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_UNUSED(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_CV_CV(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_CV_CV(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_CV_CV(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_UNUSED(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_CV_CV(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_CV_CV(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_CV_CV(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_UNUSED(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_CV_CV(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_CV_CV(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_CV_CV(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_UNUSED(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_CV_CV(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_CV_CV(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_CV_CV(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_UNUSED(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_helper_SPEC_CV_CV(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_dim_helper_SPEC_CV_CV(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
} else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_binary_assign_op_obj_helper_SPEC_CV_CV(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
+
+static int ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_CV(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_CV(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_CV(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
+
+static int ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_CV(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_CV(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_CV(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
+
+static int ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_CV(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_CV(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_CV(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
+
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_CV(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_CV(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_CV(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
+
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_CV(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_CV(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_CV(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
+
+static int ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ if (EXPECTED(opline->extended_value == 0)) {
+ return zend_binary_assign_op_helper_SPEC_CV_CV(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+ return zend_binary_assign_op_dim_helper_SPEC_CV_CV(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+ return zend_binary_assign_op_obj_helper_SPEC_CV_CV(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
+
+static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_CV(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ zval *object;
+ zval *property;
+ zval *retval;
+ zval *zptr;
+
+ SAVE_OPLINE();
+ object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+ property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ retval = EX_VAR(opline->result.var);
+
+ if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
+ }
+
+ if (IS_CV != IS_UNUSED) {
+ object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
+ }
+
+ if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(retval);
+ }
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+
+ /* here we are sure we are dealing with an object */
+
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+
+ ZVAL_DEREF(zptr);
+ SEPARATE_ZVAL_NOREF(zptr);
+
+ incdec_op(zptr);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(retval, zptr);
+ }
+ } else {
+ zval rv;
+
+ if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
+ zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+
+ if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
+ zval rv;
+ zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+
+ if (Z_REFCOUNT_P(z) == 0) {
+ zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
+ }
+ ZVAL_COPY_VALUE(z, value);
+ }
+ if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
+ SEPARATE_ZVAL_IF_NOT_REF(z);
+ incdec_op(z);
+ ZVAL_COPY_VALUE(retval, z);
+ Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+ SELECTIVE_PZVAL_LOCK(retval, opline);
+ zval_ptr_dtor(z);
+ } else {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(retval);
+ }
+ }
}
-}
-static int ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_UNUSED(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_UNUSED(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
+ return zend_pre_incdec_property_helper_SPEC_CV_CV(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_UNUSED(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
+ return zend_pre_incdec_property_helper_SPEC_CV_CV(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CV(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_UNUSED(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
+ zval *object;
+ zval *property;
+ zval *retval;
+ zval *zptr;
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ SAVE_OPLINE();
+ object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+ property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ retval = EX_VAR(opline->result.var);
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_UNUSED(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
}
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_UNUSED(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ if (IS_CV != IS_UNUSED) {
+ object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
}
-}
-static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CV_UNUSED(int type, ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- zval *varname;
- zval *retval;
- zend_string *name;
- HashTable *target_symbol_table;
+ if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
- SAVE_OPLINE();
- varname = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ ZVAL_NULL(retval);
- if (IS_CV == IS_CONST) {
- name = Z_STR_P(varname);
- } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
- name = Z_STR_P(varname);
- zend_string_addref(name);
- } else {
- name = zval_get_string(varname);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
- if (IS_UNUSED != IS_UNUSED) {
- zend_class_entry *ce;
+ /* here we are sure we are dealing with an object */
- if (IS_UNUSED == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- if (IS_CV != IS_CONST) {
- zend_string_release(name);
- }
+ if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
- }
- retval = zend_std_get_static_property(ce, name, 0, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+ ZVAL_DEREF(zptr);
+ ZVAL_COPY_VALUE(retval, zptr);
+ zval_opt_copy_ctor(zptr);
+ incdec_op(zptr);
} else {
- target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- retval = zend_hash_find(target_symbol_table, name);
- if (retval == NULL) {
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_UNSET:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_IS:
- retval = &EG(uninitialized_zval);
- break;
- case BP_VAR_RW:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_W:
- retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
- }
- /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
- } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
- retval = Z_INDIRECT_P(retval);
- if (Z_TYPE_P(retval) == IS_UNDEF) {
- switch (type) {
- case BP_VAR_R:
- case BP_VAR_UNSET:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_IS:
- retval = &EG(uninitialized_zval);
- break;
- case BP_VAR_RW:
- zend_error(E_NOTICE,"Undefined variable: %s", name->val);
- /* break missing intentionally */
- case BP_VAR_W:
- ZVAL_NULL(retval);
- break;
- EMPTY_SWITCH_DEFAULT_CASE()
+ if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
+ zval rv;
+ zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+ zval z_copy;
+
+ if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
+ zval rv;
+ zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+
+ if (Z_REFCOUNT_P(z) == 0) {
+ zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
}
+ ZVAL_COPY_VALUE(z, value);
}
- }
- if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
- if (Z_CONSTANT_P(retval)) {
- zval_update_constant(retval, 1 TSRMLS_CC);
- }
- } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
-
+ ZVAL_DUP(retval, z);
+ ZVAL_DUP(&z_copy, z);
+ incdec_op(&z_copy);
+ if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
+ Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+ zval_ptr_dtor(&z_copy);
+ zval_ptr_dtor(z);
+ } else {
+ zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+ ZVAL_NULL(retval);
}
}
- if (IS_CV != IS_CONST) {
- zend_string_release(name);
- }
- ZEND_ASSERT(retval != NULL);
- if (type == BP_VAR_R || type == BP_VAR_IS) {
- if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
- ZVAL_UNREF(retval);
- }
- ZVAL_COPY(EX_VAR(opline->result.var), retval);
- } else {
- ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
- }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_R_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_W_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_post_incdec_property_helper_SPEC_CV_CV(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_FETCH_RW_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_post_incdec_property_helper_SPEC_CV_CV(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_FETCH_FUNC_ARG_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else {
- return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
+ zval *container;
-static int ZEND_FASTCALL ZEND_FETCH_UNSET_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+ SAVE_OPLINE();
+ container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
-static int ZEND_FASTCALL ZEND_FETCH_IS_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_W_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_W_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
ZVAL_DEREF(container);
- zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
+ zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_RW_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_RW_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
ZVAL_DEREF(container);
- zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
+ zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_IS_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ zval *container;
+
+ SAVE_OPLINE();
+ container = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
+ zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
+
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *container;
zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
ZVAL_DEREF(container);
- zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
+ zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
} else {
- if (IS_UNUSED == IS_UNUSED) {
+ if (IS_CV == IS_UNUSED) {
zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
}
container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
+ zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_DIM_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_DIM_UNSET_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
- zval *object_ptr;
+ zend_free_op free_op1;
+ zval *container;
SAVE_OPLINE();
- object_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
- ZVAL_DEREF(object_ptr);
- if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
-
- zval *property_name = NULL;
-
- zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_UNUSED == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
-
- } else {
- zend_free_op free_op_data1;
- zval rv;
- zval *value;
- zval *dim = NULL;
- zval *variable_ptr;
-
- if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
- EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
- zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
-
- value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
- FREE_OP(free_op_data1);
- } else {
- zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_UNUSED TSRMLS_CC);
+ ZVAL_DEREF(container);
+ zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
- value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
- variable_ptr = Z_INDIRECT(rv);
- if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
- FREE_OP(free_op_data1);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- } else {
- value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
- if ((opline+1)->op1_type == IS_VAR) {
- FREE_OP(free_op_data1);
- }
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), value);
- }
- }
- }
+ if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
- /* assign_dim has two opcodes! */
CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *expr_ptr, new_expr;
+ zval *container;
+
+ zval *offset;
SAVE_OPLINE();
- if ((IS_CV == IS_VAR || IS_CV == IS_CV) &&
- (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
- expr_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
- }
- ZVAL_MAKE_REF(expr_ptr);
- Z_ADDREF_P(expr_ptr);
+ container = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ if ((IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+ UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+ zend_error(E_NOTICE, "Trying to get property of non-object");
+ ZVAL_NULL(EX_VAR(opline->result.var));
} else {
- expr_ptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&new_expr, expr_ptr);
- expr_ptr = &new_expr;
- } else if (IS_CV == IS_CONST) {
- if (!Z_IMMUTABLE_P(expr_ptr)) {
- ZVAL_DUP(&new_expr, expr_ptr);
- expr_ptr = &new_expr;
- }
- } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(expr_ptr)) {
- expr_ptr = Z_REFVAL_P(expr_ptr);
- if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
-
- } else if (IS_CV == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
- Z_ADDREF_P(expr_ptr);
- }
- }
-
- if (IS_UNUSED != IS_UNUSED) {
+ zval *retval;
- zval *offset = NULL;
- zend_string *str;
- zend_ulong hval;
+ /* here we are sure we are dealing with an object */
+ do {
+ if (IS_CV == IS_CONST &&
+ EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
+ zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
+ zend_object *zobj = Z_OBJ_P(container);
-add_again:
- switch (Z_TYPE_P(offset)) {
- case IS_DOUBLE:
- hval = zend_dval_to_lval(Z_DVAL_P(offset));
- goto num_index;
- case IS_LONG:
- hval = Z_LVAL_P(offset);
-num_index:
- zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
- break;
- case IS_STRING:
- str = Z_STR_P(offset);
- if (IS_UNUSED != IS_CONST) {
- if (ZEND_HANDLE_NUMERIC(str, hval)) {
- goto num_index;
+ if (EXPECTED(prop_info)) {
+ retval = OBJ_PROP(zobj, prop_info->offset);
+ if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
}
- }
-str_index:
- zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
- break;
- case IS_NULL:
- str = STR_EMPTY_ALLOC();
- goto str_index;
- case IS_FALSE:
- hval = 0;
- goto num_index;
- case IS_TRUE:
- hval = 1;
- goto num_index;
- case IS_REFERENCE:
- offset = Z_REFVAL_P(offset);
- goto add_again;
- break;
- default:
- zend_error(E_WARNING, "Illegal offset type");
- zval_ptr_dtor(expr_ptr);
- /* do nothing */
- break;
- }
-
- } else {
- zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- zval *array;
- uint32_t size;
- USE_OPLINE
-
- array = EX_VAR(opline->result.var);
- if (IS_CV != IS_UNUSED) {
- size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
- } else {
- size = 0;
- }
- ZVAL_NEW_ARR(array);
- zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
-
- if (IS_CV != IS_UNUSED) {
- /* Explicitly initialize array as not-packed if flag is set */
- if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
- zend_hash_real_init(Z_ARRVAL_P(array), 0);
- }
- }
-
- if (IS_CV == IS_UNUSED) {
- ZEND_VM_NEXT_OPCODE();
-#if 0 || IS_CV != IS_UNUSED
- } else {
- return ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-#endif
- }
-}
-
-static int ZEND_FASTCALL ZEND_UNSET_VAR_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zval tmp, *varname;
- HashTable *target_symbol_table;
-
-
- SAVE_OPLINE();
- if (IS_CV == IS_CV &&
- IS_UNUSED == IS_UNUSED &&
- (opline->extended_value & ZEND_QUICK_SET)) {
- zval *var = EX_VAR(opline->op1.var);
-
- if (Z_REFCOUNTED_P(var)) {
- zend_refcounted *garbage = Z_COUNTED_P(var);
-
- if (!--GC_REFCOUNT(garbage)) {
- ZVAL_UNDEF(var);
- _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
- } else {
- GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
- ZVAL_UNDEF(var);
- }
- } else {
- ZVAL_UNDEF(var);
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
-
- varname = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-
- ZVAL_UNDEF(&tmp);
- if (IS_CV != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
- ZVAL_STR(&tmp, zval_get_string(varname));
- varname = &tmp;
- }
-
- if (IS_UNUSED != IS_UNUSED) {
- zend_class_entry *ce;
-
- if (IS_UNUSED == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(EG(exception) != NULL)) {
- if (IS_CV != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
+ } else if (EXPECTED(zobj->properties != NULL)) {
+ retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
+ if (EXPECTED(retval)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
}
-
- HANDLE_EXCEPTION();
- }
- if (UNEXPECTED(ce == NULL)) {
- zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
}
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
}
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
- }
- zend_std_unset_static_property(ce, Z_STR_P(varname), ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
- } else {
- target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
- }
- if (IS_CV != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
+ retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+
+ if (retval != EX_VAR(opline->result.var)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ }
+ } while (0);
}
+
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_VAR_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_W_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *value;
+ zend_free_op free_op1;
+ zval *property;
+ zval *container;
SAVE_OPLINE();
- if (IS_CV == IS_CV &&
- IS_UNUSED == IS_UNUSED &&
- (opline->extended_value & ZEND_QUICK_SET)) {
- value = EX_VAR(opline->op1.var);
- if (opline->extended_value & ZEND_ISSET) {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- !i_zend_is_true(value TSRMLS_CC));
- CHECK_EXCEPTION();
- }
- ZEND_VM_NEXT_OPCODE();
- } else {
-
- zval tmp, *varname = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
-
- ZVAL_UNDEF(&tmp);
- if (IS_CV != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
- ZVAL_STR(&tmp, zval_get_string(varname));
- varname = &tmp;
- }
-
- if (IS_UNUSED != IS_UNUSED) {
- zend_class_entry *ce;
-
- if (IS_UNUSED == IS_CONST) {
- if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
- ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
- } else {
- ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
- if (UNEXPECTED(ce == NULL)) {
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
- }
- CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
- }
- } else {
- ce = Z_CE_P(EX_VAR(opline->op2.var));
- }
- value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
- } else {
- HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
- value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
- }
+ property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
- if (IS_CV != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
- zend_string_release(Z_STR(tmp));
- }
+ container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+ }
- if (opline->extended_value & ZEND_ISSET) {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- value && Z_TYPE_P(value) > IS_NULL &&
- (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
- } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
- ZVAL_BOOL(EX_VAR(opline->result.var),
- !value || !i_zend_is_true(value TSRMLS_CC));
- }
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CV, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_YIELD_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_RW_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zend_free_op free_op1;
+ zval *property;
+ zval *container;
- /* The generator object is stored in EX(return_value) */
- zend_generator *generator = (zend_generator *) EX(return_value);
+ SAVE_OPLINE();
+ property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
- zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
}
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CV, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
- /* Destroy the previously yielded value */
- zval_ptr_dtor(&generator->value);
-
- /* Destroy the previously yielded key */
- zval_ptr_dtor(&generator->key);
+ if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ }
- /* Set the new yielded value */
- if (IS_CV != IS_UNUSED) {
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
- if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
- /* Constants and temporary variables aren't yieldable by reference,
- * but we still allow them with a notice. */
- if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
- zval *value;
+ zval *container;
- zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+ zval *offset;
- value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- ZVAL_COPY_VALUE(&generator->value, value);
- if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
+ SAVE_OPLINE();
+ container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
+ offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
- /* Temporary variables don't need ctor copying */
- if (IS_CV != IS_TMP_VAR) {
- zval_opt_copy_ctor(&generator->value);
- }
- } else {
- zval *value_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ if ((IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+ UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ } else {
+ zval *retval;
- if (IS_CV == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
- }
+ /* here we are sure we are dealing with an object */
+ do {
+ if (IS_CV == IS_CONST &&
+ EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
+ zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
+ zend_object *zobj = Z_OBJ_P(container);
- /* If a function call result is yielded and the function did
- * not return by reference we throw a notice. */
- if (IS_CV == IS_VAR &&
- (value_ptr == &EG(uninitialized_zval) ||
- (opline->extended_value == ZEND_RETURNS_FUNCTION &&
- !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
- zend_error(E_NOTICE, "Only variable references should be yielded by reference");
- } else {
- ZVAL_MAKE_REF(value_ptr);
+ if (EXPECTED(prop_info)) {
+ retval = OBJ_PROP(zobj, prop_info->offset);
+ if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
+ }
+ } else if (EXPECTED(zobj->properties != NULL)) {
+ retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
+ if (EXPECTED(retval)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ break;
+ }
}
- ZVAL_COPY(&generator->value, value_ptr);
-
}
- } else {
- zval *value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- /* Consts, temporary variables and references need copying */
- if (IS_CV == IS_CONST) {
- ZVAL_DUP(&generator->value, value);
- } else if (IS_CV == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&generator->value, value);
- } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(value)) {
- ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
+ retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
- } else {
- ZVAL_COPY_VALUE(&generator->value, value);
- if (IS_CV == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
- }
+ if (retval != EX_VAR(opline->result.var)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
}
- }
- } else {
- /* If no value was specified yield null */
- ZVAL_NULL(&generator->value);
+ } while (0);
}
- /* Set the new yielded key */
- if (IS_UNUSED != IS_UNUSED) {
- zval *key = NULL;
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- /* Consts, temporary variables and references need copying */
- if (IS_UNUSED == IS_CONST) {
- ZVAL_DUP(&generator->key, key);
- } else if (IS_UNUSED == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&generator->key, key);
- } else if ((IS_UNUSED == IS_VAR || IS_UNUSED == IS_CV) && Z_ISREF_P(key)) {
- ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zval *container;
- } else {
- ZVAL_COPY_VALUE(&generator->key, key);
- if (IS_UNUSED == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
- }
+ if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+ /* Behave like FETCH_OBJ_W */
+ zend_free_op free_op1;
+ zval *property;
+
+ SAVE_OPLINE();
+ property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+
+ if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
+ zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+ }
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
}
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CV, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
- if (Z_TYPE(generator->key) == IS_LONG
- && Z_LVAL(generator->key) > generator->largest_used_integer_key
- ) {
- generator->largest_used_integer_key = Z_LVAL(generator->key);
+ if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
- } else {
- /* If no key was specified we use auto-increment keys */
- generator->largest_used_integer_key++;
- ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
- }
- if (RETURN_VALUE_USED(opline)) {
- /* If the return value of yield is used set the send
- * target and initialize it to NULL */
- generator->send_target = EX_VAR(opline->result.var);
- ZVAL_NULL(generator->send_target);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
} else {
- generator->send_target = NULL;
+ return ZEND_FETCH_OBJ_R_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-
- /* We increment to the next op, so we are at the correct position when the
- * generator is resumed. */
- ZEND_VM_INC_OPCODE();
-
- /* The GOTO VM uses a local opline variable. We need to set the opline
- * variable in execute_data so we don't resume at an old position. */
- SAVE_OPLINE();
-
- ZEND_VM_RETURN();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_binary_assign_op_helper_SPEC_CV_UNUSED(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_ADD_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_UNSET_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
+ zend_free_op free_op1;
+ zval *container, *property;
SAVE_OPLINE();
- fast_add_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
+ property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+ }
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CV, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
+ if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+ EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+ }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_SUB_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *object;
+ zval *property_name;
SAVE_OPLINE();
- fast_sub_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ object = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ property_name = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ }
+ zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+
+ /* assign_obj has two opcodes! */
CHECK_EXCEPTION();
+ ZEND_VM_INC_OPCODE();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_MUL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_DIM_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *object_ptr;
SAVE_OPLINE();
- fast_mul_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ object_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+ }
+ ZVAL_DEREF(object_ptr);
+ if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ zval *property_name = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
-static int ZEND_FASTCALL ZEND_DIV_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+ } else {
+ zend_free_op free_op_data1;
+ zval rv;
+ zval *value;
+ zval *dim = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ zval *variable_ptr;
- SAVE_OPLINE();
- fast_div_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
+ EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
+ zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
+ value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+ zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
+ FREE_OP(free_op_data1);
+ } else {
+ zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_CV TSRMLS_CC);
+
+ value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+ ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+ variable_ptr = Z_INDIRECT(rv);
+ if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
+ FREE_OP(free_op_data1);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
+ value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
+ if ((opline+1)->op1_type == IS_VAR) {
+ FREE_OP(free_op_data1);
+ }
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), value);
+ }
+ }
+ }
+ }
+ /* assign_dim has two opcodes! */
CHECK_EXCEPTION();
+ ZEND_VM_INC_OPCODE();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_MOD_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *value;
+ zval *variable_ptr;
SAVE_OPLINE();
- fast_mod_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ value = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+
+ if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
+ if (IS_CV == IS_TMP_VAR) {
+
+ }
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ } else {
+ value = zend_assign_to_variable(variable_ptr, value, IS_CV TSRMLS_CC);
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), value);
+ }
+
+ }
+ /* zend_assign_to_variable() always takes care of op2, never free it! */
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_SL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_REF_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *variable_ptr;
+ zval *value_ptr;
SAVE_OPLINE();
- shift_left_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ value_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op2.var TSRMLS_CC);
+
+ if (IS_CV == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
+ }
+ if (IS_CV == IS_VAR &&
+ (value_ptr == &EG(uninitialized_zval) ||
+ (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+ !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+ if (!0) {
+ PZVAL_LOCK(value_ptr); /* undo the effect of get_zval_ptr_ptr() */
+ }
+ zend_error(E_STRICT, "Only variables should be assigned by reference");
+ if (UNEXPECTED(EG(exception) != NULL)) {
+
+ HANDLE_EXCEPTION();
+ }
+ return ZEND_ASSIGN_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else if (IS_CV == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
+ if (!0) {
+ PZVAL_LOCK(value_ptr);
+ }
+ }
+
+ variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
+ }
+ if (IS_CV == IS_VAR &&
+ UNEXPECTED(Z_TYPE_P(EX_VAR(opline->op1.var)) != IS_INDIRECT) &&
+ UNEXPECTED(!Z_ISREF_P(variable_ptr))) {
+ zend_error_noreturn(E_ERROR, "Cannot assign by reference to overloaded object");
+ }
+ if ((IS_CV == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) ||
+ (IS_CV == IS_VAR && UNEXPECTED(value_ptr == &EG(error_zval)))) {
+ variable_ptr = &EG(uninitialized_zval);
+ } else {
+ zend_assign_to_variable_reference(variable_ptr, value_ptr TSRMLS_CC);
+ }
+
+ if (IS_CV == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
+ if (!0) {
+ Z_DELREF_P(variable_ptr);
+ }
+ }
+
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_COPY(EX_VAR(opline->result.var), variable_ptr);
+ }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_SR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *function_name;
+ zval *object;
+ zend_function *fbc;
+ zend_class_entry *called_scope;
+ zend_object *obj;
SAVE_OPLINE();
- shift_right_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ function_name = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ if (IS_CV != IS_CONST &&
+ UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ }
+ zend_error_noreturn(E_ERROR, "Method name must be a string");
+ }
+
+ object = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+
+ if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+ uint32_t nesting = 1;
+
+ if (UNEXPECTED(EG(exception) != NULL)) {
+
+ HANDLE_EXCEPTION();
+ }
+
+ zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s", Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
+
+
+ if (EG(exception) != NULL) {
+ HANDLE_EXCEPTION();
+ }
+
+ /* No exception raised: Skip over arguments until fcall opcode with correct
+ * nesting level. Return NULL (except when return value unused) */
+ do {
+ opline++;
+ if (opline->opcode == ZEND_INIT_FCALL ||
+ opline->opcode == ZEND_INIT_FCALL_BY_NAME ||
+ opline->opcode == ZEND_INIT_NS_FCALL_BY_NAME ||
+ opline->opcode == ZEND_INIT_METHOD_CALL ||
+ opline->opcode == ZEND_INIT_STATIC_METHOD_CALL ||
+ opline->opcode == ZEND_INIT_USER_CALL ||
+ opline->opcode == ZEND_NEW
+ ) {
+ nesting++;
+ } else if (opline->opcode == ZEND_DO_FCALL) {
+ nesting--;
+ }
+ } while (nesting);
-static int ZEND_FASTCALL ZEND_CONCAT_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ if (RETURN_VALUE_USED(opline)) {
+ ZVAL_NULL(EX_VAR(opline->result.var));
+ }
+ /* We've skipped EXT_FCALL_BEGIND, so also skip the ending opcode */
+ if ((opline + 1)->opcode == ZEND_EXT_FCALL_END) {
+ opline++;
+ }
+ ZEND_VM_JMP(++opline);
+ }
- SAVE_OPLINE();
- concat_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ obj = Z_OBJ_P(object);
+ called_scope = obj->ce;
+ if (IS_CV != IS_CONST ||
+ EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
+ zend_object *orig_obj = obj;
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ if (UNEXPECTED(obj->handlers->get_method == NULL)) {
+ zend_error_noreturn(E_ERROR, "Object does not support method calls");
+ }
-static int ZEND_FASTCALL ZEND_IS_IDENTICAL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ /* First, locate the function. */
+ fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_CV == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
+ if (UNEXPECTED(fbc == NULL)) {
+ zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
+ }
+ if (IS_CV == IS_CONST &&
+ EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
+ EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
+ EXPECTED(obj == orig_obj)) {
+ CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope, fbc);
+ }
+ }
+ if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_STATIC) != 0)) {
+ obj = NULL;
+ } else {
+ GC_REFCOUNT(obj)++; /* For $this pointer */
+ }
- SAVE_OPLINE();
- fast_is_identical_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
+ fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_IS_NOT_IDENTICAL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_CASE_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *result = EX_VAR(opline->result.var);
SAVE_OPLINE();
- fast_is_not_identical_function(result,
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
+ fast_equal_function(result,
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_IS_EQUAL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *result = EX_VAR(opline->result.var);
+ zval *expr_ptr, new_expr;
SAVE_OPLINE();
- fast_equal_function(result,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
+ if ((IS_CV == IS_VAR || IS_CV == IS_CV) &&
+ (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
+ expr_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+ if (IS_CV == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
+ }
+ ZVAL_MAKE_REF(expr_ptr);
+ Z_ADDREF_P(expr_ptr);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ } else {
+ expr_ptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ if (IS_CV == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&new_expr, expr_ptr);
+ expr_ptr = &new_expr;
+ } else if (IS_CV == IS_CONST) {
+ if (!Z_IMMUTABLE_P(expr_ptr)) {
+ ZVAL_DUP(&new_expr, expr_ptr);
+ expr_ptr = &new_expr;
+ }
+ } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(expr_ptr)) {
+ expr_ptr = Z_REFVAL_P(expr_ptr);
+ if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
-static int ZEND_FASTCALL ZEND_IS_NOT_EQUAL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ } else if (IS_CV == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
+ Z_ADDREF_P(expr_ptr);
+ }
+ }
- zval *result = EX_VAR(opline->result.var);
+ if (IS_CV != IS_UNUSED) {
- SAVE_OPLINE();
- fast_not_equal_function(result,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ zval *offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ zend_string *str;
+ zend_ulong hval;
+add_again:
+ switch (Z_TYPE_P(offset)) {
+ case IS_DOUBLE:
+ hval = zend_dval_to_lval(Z_DVAL_P(offset));
+ goto num_index;
+ case IS_LONG:
+ hval = Z_LVAL_P(offset);
+num_index:
+ zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
+ break;
+ case IS_STRING:
+ str = Z_STR_P(offset);
+ if (IS_CV != IS_CONST) {
+ if (ZEND_HANDLE_NUMERIC(str, hval)) {
+ goto num_index;
+ }
+ }
+str_index:
+ zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
+ break;
+ case IS_NULL:
+ str = STR_EMPTY_ALLOC();
+ goto str_index;
+ case IS_FALSE:
+ hval = 0;
+ goto num_index;
+ case IS_TRUE:
+ hval = 1;
+ goto num_index;
+ case IS_REFERENCE:
+ offset = Z_REFVAL_P(offset);
+ goto add_again;
+ break;
+ default:
+ zend_error(E_WARNING, "Illegal offset type");
+ zval_ptr_dtor(expr_ptr);
+ /* do nothing */
+ break;
+ }
+ } else {
+ zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
+ }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_IS_SMALLER_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
+ zval *array;
+ uint32_t size;
USE_OPLINE
- zval *result = EX_VAR(opline->result.var);
-
- SAVE_OPLINE();
- fast_is_smaller_function(result,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ array = EX_VAR(opline->result.var);
+ if (IS_CV != IS_UNUSED) {
+ size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
+ } else {
+ size = 0;
+ }
+ ZVAL_NEW_ARR(array);
+ zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
+ if (IS_CV != IS_UNUSED) {
+ /* Explicitly initialize array as not-packed if flag is set */
+ if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
+ zend_hash_real_init(Z_ARRVAL_P(array), 0);
+ }
+ }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (IS_CV == IS_UNUSED) {
+ ZEND_VM_NEXT_OPCODE();
+#if 0 || IS_CV != IS_UNUSED
+ } else {
+ return ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+#endif
+ }
}
-static int ZEND_FASTCALL ZEND_IS_SMALLER_OR_EQUAL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_UNSET_DIM_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *result = EX_VAR(opline->result.var);
+ zval *container;
+ zval *offset;
+ zend_ulong hval;
SAVE_OPLINE();
- fast_is_smaller_or_equal_function(result,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
+ }
+ if (IS_CV != IS_UNUSED) {
+ ZVAL_DEREF(container);
+ }
+ SEPARATE_ZVAL_NOREF(container);
+ offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+
+ if (IS_CV != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
+ HashTable *ht = Z_ARRVAL_P(container);
+offset_again:
+ switch (Z_TYPE_P(offset)) {
+ case IS_DOUBLE:
+ hval = zend_dval_to_lval(Z_DVAL_P(offset));
+ zend_hash_index_del(ht, hval);
+ break;
+ case IS_LONG:
+ hval = Z_LVAL_P(offset);
+num_index_dim:
+ zend_hash_index_del(ht, hval);
+ break;
+ case IS_STRING:
+ if (IS_CV != IS_CONST) {
+ if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
+ goto num_index_dim;
+ }
+ }
+ if (ht == &EG(symbol_table).ht) {
+ zend_delete_global_variable(Z_STR_P(offset) TSRMLS_CC);
+ } else {
+ zend_hash_del(ht, Z_STR_P(offset));
+ }
+ break;
+ case IS_NULL:
+ zend_hash_del(ht, STR_EMPTY_ALLOC());
+ break;
+ case IS_FALSE:
+ hval = 0;
+ goto num_index_dim;
+ case IS_TRUE:
+ hval = 1;
+ goto num_index_dim;
+ case IS_RESOURCE:
+ hval = Z_RES_HANDLE_P(offset);
+ goto num_index_dim;
+ case IS_REFERENCE:
+ offset = Z_REFVAL_P(offset);
+ goto offset_again;
+ break;
+ default:
+ zend_error(E_WARNING, "Illegal offset type in unset");
+ break;
+ }
+
+ } else if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot use object as array");
+ }
+//??? if (IS_CV == IS_CONST) {
+//??? zval_copy_ctor(offset);
+//??? }
+ Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
+
+ } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
+ ZEND_VM_CONTINUE(); /* bailed out before */
+ } else {
+ }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_BW_OR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_UNSET_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *container;
+ zval *offset;
SAVE_OPLINE();
- bitwise_or_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
+ if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
+ }
+ offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+
+ if (IS_CV != IS_UNUSED) {
+ ZVAL_DEREF(container);
+ }
+ if (IS_CV == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
+ if (Z_OBJ_HT_P(container)->unset_property) {
+ Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+ } else {
+ zend_error(E_NOTICE, "Trying to unset property of non-object");
+ }
+ }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_BW_AND_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *container;
+ int result;
+ zend_ulong hval;
+ zval *offset;
SAVE_OPLINE();
- bitwise_and_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
+ container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
+ offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ if (IS_CV != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
+ HashTable *ht = Z_ARRVAL_P(container);
+ zval *value;
+ zend_string *str;
-static int ZEND_FASTCALL ZEND_BW_XOR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+isset_again:
+ if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
+ str = Z_STR_P(offset);
+ if (IS_CV != IS_CONST) {
+ if (ZEND_HANDLE_NUMERIC(str, hval)) {
+ goto num_index_prop;
+ }
+ }
+str_index_prop:
+ value = zend_hash_find_ind(ht, str);
+ } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
+ hval = Z_LVAL_P(offset);
+num_index_prop:
+ value = zend_hash_index_find(ht, hval);
+ } else {
+ switch (Z_TYPE_P(offset)) {
+ case IS_DOUBLE:
+ hval = zend_dval_to_lval(Z_DVAL_P(offset));
+ goto num_index_prop;
+ case IS_NULL:
+ str = STR_EMPTY_ALLOC();
+ goto str_index_prop;
+ case IS_FALSE:
+ hval = 0;
+ goto num_index_prop;
+ case IS_TRUE:
+ hval = 1;
+ goto num_index_prop;
+ case IS_RESOURCE:
+ hval = Z_RES_HANDLE_P(offset);
+ goto num_index_prop;
+ case IS_REFERENCE:
+ offset = Z_REFVAL_P(offset);
+ goto isset_again;
+ default:
+ zend_error(E_WARNING, "Illegal offset type in isset or empty");
+ value = NULL;
+ break;
+ }
+ }
+ if (opline->extended_value & ZEND_ISSET) {
+ /* > IS_NULL means not IS_UNDEF and not IS_NULL */
+ result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
+ (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
+ } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+ result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
+ }
+ } else if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
+ result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
+ } else {
+ zend_error(E_NOTICE, "Trying to check element of non-array");
+ result = 0;
+ }
+ if ((opline->extended_value & ZEND_ISSET) == 0) {
+ result = !result;
+ }
+ } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
+ zval tmp;
- SAVE_OPLINE();
- bitwise_xor_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ result = 0;
+ if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
+ if (IS_CV & (IS_CV|IS_VAR)) {
+ ZVAL_DEREF(offset);
+ }
+ if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
+ || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
+ && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
+ ZVAL_DUP(&tmp, offset);
+ convert_to_long(&tmp);
+ offset = &tmp;
+ }
+ }
+ if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
+ if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
+ if ((opline->extended_value & ZEND_ISSET) ||
+ Z_STRVAL_P(container)[offset->value.lval] != '0') {
+ result = 1;
+ }
+ }
+ }
+ if ((opline->extended_value & ZEND_ISSET) == 0) {
+ result = !result;
+ }
+ } else {
+ result = ((opline->extended_value & ZEND_ISSET) == 0);
+ }
+ ZVAL_BOOL(EX_VAR(opline->result.var), result);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_BOOL_XOR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval *container;
+ int result;
+ zval *offset;
SAVE_OPLINE();
- boolean_xor_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
+ offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+
+ if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
+ result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+ } else {
+ zend_error(E_NOTICE, "Trying to check property of non-object");
+ result = 0;
+ }
+ if ((opline->extended_value & ZEND_ISSET) == 0) {
+ result = !result;
+ }
+ } else {
+ result = ((opline->extended_value & ZEND_ISSET) == 0);
+ }
+ ZVAL_BOOL(EX_VAR(opline->result.var), result);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_CV(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_YIELD_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op_data1;
- zval *object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- zval *property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
- zval *value;
- zval *zptr;
- if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
- }
+ /* The generator object is stored in EX(return_value) */
+ zend_generator *generator = (zend_generator *) EX(return_value);
- if (IS_CV != IS_UNUSED) {
- object = make_real_object(object TSRMLS_CC);
+ if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
+ zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
}
- value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+ /* Destroy the previously yielded value */
+ zval_ptr_dtor(&generator->value);
- if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
- zend_error(E_WARNING, "Attempt to assign property of non-object");
+ /* Destroy the previously yielded key */
+ zval_ptr_dtor(&generator->key);
- FREE_OP(free_op_data1);
+ /* Set the new yielded value */
+ if (IS_CV != IS_UNUSED) {
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- } else {
- /* here we are sure we are dealing with an object */
- if (opline->extended_value == ZEND_ASSIGN_OBJ
- && EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
- ZVAL_DEREF(zptr);
- SEPARATE_ZVAL_NOREF(zptr);
+ if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
+ /* Constants and temporary variables aren't yieldable by reference,
+ * but we still allow them with a notice. */
+ if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
+ zval *value;
- binary_op(zptr, zptr, value TSRMLS_CC);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), zptr);
- }
- } else {
- zval *z = NULL;
- zval rv;
+ zend_error(E_NOTICE, "Only variable references should be yielded by reference");
- if (opline->extended_value == ZEND_ASSIGN_OBJ) {
- if (Z_OBJ_HT_P(object)->read_property) {
- z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
- }
- } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
- if (Z_OBJ_HT_P(object)->read_dimension) {
- z = Z_OBJ_HT_P(object)->read_dimension(object, property, BP_VAR_R, &rv TSRMLS_CC);
- }
- }
- if (z) {
- if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
- zval rv;
- zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+ value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+ ZVAL_COPY_VALUE(&generator->value, value);
+ if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
- if (Z_REFCOUNT_P(z) == 0) {
- zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
- }
- ZVAL_COPY_VALUE(z, value);
+ /* Temporary variables don't need ctor copying */
+ if (IS_CV != IS_TMP_VAR) {
+ zval_opt_copy_ctor(&generator->value);
}
-//??? if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
- SEPARATE_ZVAL_IF_NOT_REF(z);
- binary_op(z, z, value TSRMLS_CC);
- if (opline->extended_value == ZEND_ASSIGN_OBJ) {
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
- } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
- Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
+ } else {
+ zval *value_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+
+ if (IS_CV == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+ zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
}
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), z);
+
+ /* If a function call result is yielded and the function did
+ * not return by reference we throw a notice. */
+ if (IS_CV == IS_VAR &&
+ (value_ptr == &EG(uninitialized_zval) ||
+ (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+ !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+ zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+ } else {
+ ZVAL_MAKE_REF(value_ptr);
}
- zval_ptr_dtor(z);
+ ZVAL_COPY(&generator->value, value_ptr);
+
+ }
+ } else {
+ zval *value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+
+ /* Consts, temporary variables and references need copying */
+ if (IS_CV == IS_CONST) {
+ ZVAL_DUP(&generator->value, value);
+ } else if (IS_CV == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&generator->value, value);
+ } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(value)) {
+ ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
+
} else {
- zend_error(E_WARNING, "Attempt to assign property of non-object");
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
+ ZVAL_COPY_VALUE(&generator->value, value);
+ if (IS_CV == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
}
}
}
-
- FREE_OP(free_op_data1);
+ } else {
+ /* If no value was specified yield null */
+ ZVAL_NULL(&generator->value);
}
- /* assign_obj has two opcodes! */
- CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_CV_CV(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op_data1;
- zval *var_ptr, rv;
- zval *value, *container;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
+ /* Set the new yielded key */
if (IS_CV != IS_UNUSED) {
- ZVAL_DEREF(container);
- }
- if (IS_CV == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (IS_CV == IS_VAR && !0) {
- Z_ADDREF_P(container); /* undo the effect of get_obj_zval_ptr_ptr() */
- }
- return zend_binary_assign_op_obj_helper_SPEC_CV_CV(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else {
- zval *dim = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
- zend_fetch_dimension_address_RW(&rv, container, dim, IS_CV TSRMLS_CC);
- value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
- var_ptr = Z_INDIRECT(rv);
- }
+ zval *key = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
- if (UNEXPECTED(var_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
- }
+ /* Consts, temporary variables and references need copying */
+ if (IS_CV == IS_CONST) {
+ ZVAL_DUP(&generator->key, key);
+ } else if (IS_CV == IS_TMP_VAR) {
+ ZVAL_COPY_VALUE(&generator->key, key);
+ } else if ((IS_CV == IS_VAR || IS_CV == IS_CV) && Z_ISREF_P(key)) {
+ ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
- if (UNEXPECTED(var_ptr == &EG(error_zval))) {
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_NULL(EX_VAR(opline->result.var));
+ } else {
+ ZVAL_COPY_VALUE(&generator->key, key);
+ if (IS_CV == IS_CV) {
+ if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
+ }
}
- } else {
- ZVAL_DEREF(var_ptr);
- SEPARATE_ZVAL_NOREF(var_ptr);
-
- binary_op(var_ptr, var_ptr, value TSRMLS_CC);
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+ if (Z_TYPE(generator->key) == IS_LONG
+ && Z_LVAL(generator->key) > generator->largest_used_integer_key
+ ) {
+ generator->largest_used_integer_key = Z_LVAL(generator->key);
}
+ } else {
+ /* If no key was specified we use auto-increment keys */
+ generator->largest_used_integer_key++;
+ ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
}
- FREE_OP(free_op_data1);
+ if (RETURN_VALUE_USED(opline)) {
+ /* If the return value of yield is used set the send
+ * target and initialize it to NULL */
+ generator->send_target = EX_VAR(opline->result.var);
+ ZVAL_NULL(generator->send_target);
+ } else {
+ generator->send_target = NULL;
+ }
- CHECK_EXCEPTION();
+ /* We increment to the next op, so we are at the correct position when the
+ * generator is resumed. */
ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
+
+ /* The GOTO VM uses a local opline variable. We need to set the opline
+ * variable in execute_data so we don't resume at an old position. */
+ SAVE_OPLINE();
+
+ ZEND_VM_RETURN();
}
-static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_CV(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_POW_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zval *var_ptr;
- zval *value;
SAVE_OPLINE();
- value = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
- var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
-
- if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
- }
-
- if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- } else {
- ZVAL_DEREF(var_ptr);
- SEPARATE_ZVAL_NOREF(var_ptr);
-
- binary_op(var_ptr, var_ptr, value TSRMLS_CC);
-
- if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
- ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
- }
- }
+ pow_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_ADD_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- USE_OPLINE
-
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_CV(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_CV(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_CV(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
+ return zend_binary_assign_op_helper_SPEC_CV_CV(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_ASSIGN_SUB_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ADD_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zend_free_op free_op2;
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_CV(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_CV(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_CV(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_MUL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ SAVE_OPLINE();
+ fast_add_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_CV(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_CV(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_CV(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
+ zval_ptr_dtor_nogc(free_op2);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_DIV_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_SUB_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zend_free_op free_op2;
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_CV(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_CV(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_CV(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_MOD_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ SAVE_OPLINE();
+ fast_sub_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_CV(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_CV(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_CV(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
+ zval_ptr_dtor_nogc(free_op2);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_SL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_MUL_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zend_free_op free_op2;
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_CV(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_CV(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_CV(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
+ SAVE_OPLINE();
+ fast_mul_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+
+ zval_ptr_dtor_nogc(free_op2);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_SR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_DIV_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zend_free_op free_op2;
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_CV(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_CV(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_CV(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
+ SAVE_OPLINE();
+ fast_div_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+
+ zval_ptr_dtor_nogc(free_op2);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_CONCAT_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_IS_EQUAL_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zend_free_op free_op2;
+ zval *result = EX_VAR(opline->result.var);
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_CV(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_CV(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_CV(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
+ SAVE_OPLINE();
+ fast_equal_function(result,
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+
+ zval_ptr_dtor_nogc(free_op2);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_OR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_IS_NOT_EQUAL_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zend_free_op free_op2;
+ zval *result = EX_VAR(opline->result.var);
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_CV(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_CV(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_CV(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
+ SAVE_OPLINE();
+ fast_not_equal_function(result,
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+
+ zval_ptr_dtor_nogc(free_op2);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_AND_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_IS_SMALLER_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zend_free_op free_op2;
+ zval *result = EX_VAR(opline->result.var);
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_CV(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_CV(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_CV(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
+ SAVE_OPLINE();
+ fast_is_smaller_function(result,
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+
+ zval_ptr_dtor_nogc(free_op2);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_BW_XOR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_IS_SMALLER_OR_EQUAL_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zend_free_op free_op2;
+ zval *result = EX_VAR(opline->result.var);
- if (EXPECTED(opline->extended_value == 0)) {
- return zend_binary_assign_op_helper_SPEC_CV_CV(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
- return zend_binary_assign_op_dim_helper_SPEC_CV_CV(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
- return zend_binary_assign_op_obj_helper_SPEC_CV_CV(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- }
+ SAVE_OPLINE();
+ fast_is_smaller_or_equal_function(result,
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+ _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+
+ zval_ptr_dtor_nogc(free_op2);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_CV(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_TMPVAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
+ zend_free_op free_op2;
zval *object;
zval *property;
zval *retval;
SAVE_OPLINE();
object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
retval = EX_VAR(opline->result.var);
if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-
+ zval_ptr_dtor_nogc(free_op2);
if (RETURN_VALUE_USED(opline)) {
ZVAL_NULL(retval);
}
/* here we are sure we are dealing with an object */
if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
ZVAL_DEREF(zptr);
SEPARATE_ZVAL_NOREF(zptr);
zval rv;
if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
- zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+ zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
zval rv;
SEPARATE_ZVAL_IF_NOT_REF(z);
incdec_op(z);
ZVAL_COPY_VALUE(retval, z);
- Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+ Z_OBJ_HT_P(object)->write_property(object, property, z, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
SELECTIVE_PZVAL_LOCK(retval, opline);
zval_ptr_dtor(z);
} else {
}
}
+ zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_PRE_INC_OBJ_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_pre_incdec_property_helper_SPEC_CV_CV(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_pre_incdec_property_helper_SPEC_CV_TMPVAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_PRE_DEC_OBJ_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_pre_incdec_property_helper_SPEC_CV_CV(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_pre_incdec_property_helper_SPEC_CV_TMPVAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CV(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_TMPVAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
+ zend_free_op free_op2;
zval *object;
zval *property;
zval *retval;
SAVE_OPLINE();
object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
- property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
retval = EX_VAR(opline->result.var);
if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-
+ zval_ptr_dtor_nogc(free_op2);
ZVAL_NULL(retval);
CHECK_EXCEPTION();
/* here we are sure we are dealing with an object */
if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
- && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+ && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
ZVAL_DEREF(zptr);
ZVAL_COPY_VALUE(retval, zptr);
} else {
if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
zval rv;
- zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+ zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
zval z_copy;
if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
ZVAL_DUP(&z_copy, z);
incdec_op(&z_copy);
if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
- Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+ Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
zval_ptr_dtor(&z_copy);
zval_ptr_dtor(z);
} else {
}
}
+ zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_post_incdec_property_helper_SPEC_CV_CV(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- return zend_post_incdec_property_helper_SPEC_CV_CV(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_DIM_R_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- zval *container;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
-
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_DIM_W_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *container;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
-
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_DIM_RW_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
- zval *container;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
-
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
-
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_DIM_IS_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- zval *container;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
- zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
-
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_POST_INC_OBJ_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- USE_OPLINE
- zval *container;
- zend_free_op free_op1;
-
- SAVE_OPLINE();
-
- if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
- if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
- zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
- }
- container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
-
-
- } else {
- if (IS_CV == IS_UNUSED) {
- zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
- }
- container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
-
-
- }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ return zend_post_incdec_property_helper_SPEC_CV_TMPVAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_FETCH_DIM_UNSET_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_POST_DEC_OBJ_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- USE_OPLINE
- zend_free_op free_op1;
- zval *container;
-
- SAVE_OPLINE();
- container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
-
- if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(container);
- zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
-
- if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
- EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
- }
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ return zend_post_incdec_property_helper_SPEC_CV_TMPVAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_R_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *container;
-
+ zend_free_op free_op2;
zval *offset;
SAVE_OPLINE();
container = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
if ((IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
/* here we are sure we are dealing with an object */
do {
- if (IS_CV == IS_CONST &&
+ if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
zend_object *zobj = Z_OBJ_P(container);
}
}
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+ retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
if (retval != EX_VAR(opline->result.var)) {
ZVAL_COPY(EX_VAR(opline->result.var), retval);
} while (0);
}
+ zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_W_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_W_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
+ zend_free_op free_op1, free_op2;
zval *property;
zval *container;
SAVE_OPLINE();
- property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
}
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CV, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
-
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_RW_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_RW_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
+ zend_free_op free_op1, free_op2;
zval *property;
zval *container;
SAVE_OPLINE();
- property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
}
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CV, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
-
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_IS_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *container;
-
+ zend_free_op free_op2;
zval *offset;
SAVE_OPLINE();
container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
- offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
if ((IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
/* here we are sure we are dealing with an object */
do {
- if (IS_CV == IS_CONST &&
+ if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
zend_object *zobj = Z_OBJ_P(container);
}
}
- retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+ retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
if (retval != EX_VAR(opline->result.var)) {
ZVAL_COPY(EX_VAR(opline->result.var), retval);
} while (0);
}
+ zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *container;
if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
/* Behave like FETCH_OBJ_W */
- zend_free_op free_op1;
+ zend_free_op free_op1, free_op2;
zval *property;
SAVE_OPLINE();
- property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
}
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CV, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
-
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
} else {
- return ZEND_FETCH_OBJ_R_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return ZEND_FETCH_OBJ_R_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
}
-static int ZEND_FASTCALL ZEND_FETCH_OBJ_UNSET_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_OBJ_UNSET_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
+ zend_free_op free_op1, free_op2;
zval *container, *property;
SAVE_OPLINE();
container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
- property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
}
- zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CV, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
-
+ zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ASSIGN_OBJ_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
+ zend_free_op free_op2;
zval *object;
zval *property_name;
SAVE_OPLINE();
object = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- property_name = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ property_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
}
- zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
-
+ zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
/* assign_obj has two opcodes! */
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ASSIGN_DIM_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- zval *object_ptr;
-
- SAVE_OPLINE();
- object_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-
- if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
- }
- ZVAL_DEREF(object_ptr);
- if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
-
- zval *property_name = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
-
- zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
-
- } else {
- zend_free_op free_op_data1;
- zval rv;
- zval *value;
- zval *dim = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
- zval *variable_ptr;
-
- if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
- EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
- zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
-
- value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
- FREE_OP(free_op_data1);
- } else {
- zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_CV TSRMLS_CC);
-
- value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
- ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
- variable_ptr = Z_INDIRECT(rv);
- if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
- FREE_OP(free_op_data1);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- } else {
- value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
- if ((opline+1)->op1_type == IS_VAR) {
- FREE_OP(free_op_data1);
- }
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), value);
- }
- }
- }
- }
-
- /* assign_dim has two opcodes! */
- CHECK_EXCEPTION();
- ZEND_VM_INC_OPCODE();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- zval *value;
- zval *variable_ptr;
-
- SAVE_OPLINE();
- value = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
- variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-
- if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
- if (IS_CV == IS_TMP_VAR) {
-
- }
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_NULL(EX_VAR(opline->result.var));
- }
- } else {
- value = zend_assign_to_variable(variable_ptr, value, IS_CV TSRMLS_CC);
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), value);
- }
-
- }
-
- /* zend_assign_to_variable() always takes care of op2, never free it! */
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_ASSIGN_REF_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
-
- zval *variable_ptr;
- zval *value_ptr;
-
- SAVE_OPLINE();
- value_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op2.var TSRMLS_CC);
-
- if (IS_CV == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
- }
- if (IS_CV == IS_VAR &&
- (value_ptr == &EG(uninitialized_zval) ||
- (opline->extended_value == ZEND_RETURNS_FUNCTION &&
- !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
- if (!0) {
- PZVAL_LOCK(value_ptr); /* undo the effect of get_zval_ptr_ptr() */
- }
- zend_error(E_STRICT, "Only variables should be assigned by reference");
- if (UNEXPECTED(EG(exception) != NULL)) {
-
- HANDLE_EXCEPTION();
- }
- return ZEND_ASSIGN_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
- } else if (IS_CV == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
- if (!0) {
- PZVAL_LOCK(value_ptr);
- }
- }
-
- variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
- if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
- }
- if (IS_CV == IS_VAR &&
- UNEXPECTED(Z_TYPE_P(EX_VAR(opline->op1.var)) != IS_INDIRECT) &&
- UNEXPECTED(!Z_ISREF_P(variable_ptr))) {
- zend_error_noreturn(E_ERROR, "Cannot assign by reference to overloaded object");
- }
- if ((IS_CV == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) ||
- (IS_CV == IS_VAR && UNEXPECTED(value_ptr == &EG(error_zval)))) {
- variable_ptr = &EG(uninitialized_zval);
- } else {
- zend_assign_to_variable_reference(variable_ptr, value_ptr TSRMLS_CC);
- }
-
- if (IS_CV == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
- if (!0) {
- Z_DELREF_P(variable_ptr);
- }
- }
-
- if (RETURN_VALUE_USED(opline)) {
- ZVAL_COPY(EX_VAR(opline->result.var), variable_ptr);
- }
-
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INIT_METHOD_CALL_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zval *function_name;
-
+ zend_free_op free_op2;
zval *object;
zend_function *fbc;
zend_class_entry *called_scope;
SAVE_OPLINE();
- function_name = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ function_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
- if (IS_CV != IS_CONST &&
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST &&
UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
if (UNEXPECTED(EG(exception) != NULL)) {
HANDLE_EXCEPTION();
uint32_t nesting = 1;
if (UNEXPECTED(EG(exception) != NULL)) {
-
+ zval_ptr_dtor_nogc(free_op2);
HANDLE_EXCEPTION();
}
zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s", Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
-
+ zval_ptr_dtor_nogc(free_op2);
if (EG(exception) != NULL) {
HANDLE_EXCEPTION();
obj = Z_OBJ_P(object);
called_scope = obj->ce;
- if (IS_CV != IS_CONST ||
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST ||
EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
zend_object *orig_obj = obj;
}
/* First, locate the function. */
- fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_CV == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
+ fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
if (UNEXPECTED(fbc == NULL)) {
zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
}
- if (IS_CV == IS_CONST &&
+ if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
EXPECTED(obj == orig_obj)) {
EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_CASE_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_CASE_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
+ zend_free_op free_op2;
zval *result = EX_VAR(opline->result.var);
SAVE_OPLINE();
fast_equal_function(result,
_get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+ _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
}
}
- if (IS_CV != IS_UNUSED) {
-
- zval *offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ if ((IS_TMP_VAR|IS_VAR) != IS_UNUSED) {
+ zend_free_op free_op2;
+ zval *offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
zend_string *str;
zend_ulong hval;
break;
case IS_STRING:
str = Z_STR_P(offset);
- if (IS_CV != IS_CONST) {
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
if (ZEND_HANDLE_NUMERIC(str, hval)) {
goto num_index;
}
/* do nothing */
break;
}
-
+ zval_ptr_dtor_nogc(free_op2);
} else {
zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
}
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_INIT_ARRAY_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
zval *array;
uint32_t size;
ZEND_VM_NEXT_OPCODE();
#if 0 || IS_CV != IS_UNUSED
} else {
- return ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
#endif
}
}
-static int ZEND_FASTCALL ZEND_UNSET_DIM_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_UNSET_DIM_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
+ zend_free_op free_op2;
zval *container;
zval *offset;
zend_ulong hval;
ZVAL_DEREF(container);
}
SEPARATE_ZVAL_NOREF(container);
- offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
if (IS_CV != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
HashTable *ht = Z_ARRVAL_P(container);
zend_hash_index_del(ht, hval);
break;
case IS_STRING:
- if (IS_CV != IS_CONST) {
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
goto num_index_dim;
}
zend_error(E_WARNING, "Illegal offset type in unset");
break;
}
-
+ zval_ptr_dtor_nogc(free_op2);
} else if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot use object as array");
}
-//??? if (IS_CV == IS_CONST) {
+//??? if ((IS_TMP_VAR|IS_VAR) == IS_CONST) {
//??? zval_copy_ctor(offset);
//??? }
Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
-
+ zval_ptr_dtor_nogc(free_op2);
} else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
ZEND_VM_CONTINUE(); /* bailed out before */
} else {
-
+ zval_ptr_dtor_nogc(free_op2);
}
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_UNSET_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_UNSET_OBJ_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
+ zend_free_op free_op2;
zval *container;
zval *offset;
if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
}
- offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
if (IS_CV != IS_UNUSED) {
ZVAL_DEREF(container);
}
if (IS_CV == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
if (Z_OBJ_HT_P(container)->unset_property) {
- Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+ Z_OBJ_HT_P(container)->unset_property(container, offset, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
} else {
zend_error(E_NOTICE, "Trying to unset property of non-object");
}
}
-
+ zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
+ zend_free_op free_op2;
zval *container;
int result;
zend_ulong hval;
SAVE_OPLINE();
container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
- offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
if (IS_CV != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
HashTable *ht = Z_ARRVAL_P(container);
isset_again:
if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
str = Z_STR_P(offset);
- if (IS_CV != IS_CONST) {
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
if (ZEND_HANDLE_NUMERIC(str, hval)) {
goto num_index_prop;
}
result = 0;
if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
- if (IS_CV == IS_CV || IS_CV == IS_VAR) {
+ if ((IS_TMP_VAR|IS_VAR) & (IS_CV|IS_VAR)) {
ZVAL_DEREF(offset);
}
if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
result = ((opline->extended_value & ZEND_ISSET) == 0);
}
+ zval_ptr_dtor_nogc(free_op2);
+ ZVAL_BOOL(EX_VAR(opline->result.var), result);
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op2;
+ zval *container;
+ int result;
+ zval *offset;
+
+ SAVE_OPLINE();
+ container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
+ offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+
+ if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+ if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
+ result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+ } else {
+ zend_error(E_NOTICE, "Trying to check property of non-object");
+ result = 0;
+ }
+ if ((opline->extended_value & ZEND_ISSET) == 0) {
+ result = !result;
+ }
+ } else {
+ result = ((opline->extended_value & ZEND_ISSET) == 0);
+ }
+
+ zval_ptr_dtor_nogc(free_op2);
ZVAL_BOOL(EX_VAR(opline->result.var), result);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FREE_SPEC_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+
+ SAVE_OPLINE();
+ zval_ptr_dtor_nogc(EX_VAR(opline->op1.var));
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_BOOL_SPEC_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+ zval *retval = EX_VAR(opline->result.var);
+
+ SAVE_OPLINE();
+ /* PHP 3.0 returned "" for false and 1 for true, here we use 0 and 1 for now */
+ ZVAL_BOOL(retval, i_zend_is_true(_get_zval_ptr_var(opline->op1.var, execute_data, &free_op1) TSRMLS_CC));
+ zval_ptr_dtor_nogc(free_op1);
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_INCLUDE_OR_EVAL_SPEC_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_op_array *new_op_array=NULL;
+ zend_free_op free_op1;
+ zval *inc_filename;
+ zval tmp_inc_filename;
+ zend_bool failure_retval=0;
+
+ SAVE_OPLINE();
+ inc_filename = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+
+ ZVAL_UNDEF(&tmp_inc_filename);
+ if (Z_TYPE_P(inc_filename) != IS_STRING) {
+ ZVAL_STR(&tmp_inc_filename, zval_get_string(inc_filename));
+ inc_filename = &tmp_inc_filename;
+ }
+
+ if (opline->extended_value != ZEND_EVAL && strlen(Z_STRVAL_P(inc_filename)) != Z_STRLEN_P(inc_filename)) {
+ if (opline->extended_value == ZEND_INCLUDE_ONCE || opline->extended_value == ZEND_INCLUDE) {
+ zend_message_dispatcher(ZMSG_FAILED_INCLUDE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
+ } else {
+ zend_message_dispatcher(ZMSG_FAILED_REQUIRE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
+ }
+ } else {
+ switch (opline->extended_value) {
+ case ZEND_INCLUDE_ONCE:
+ case ZEND_REQUIRE_ONCE: {
+ zend_file_handle file_handle;
+ char *resolved_path;
+
+ resolved_path = zend_resolve_path(Z_STRVAL_P(inc_filename), (int)Z_STRLEN_P(inc_filename) TSRMLS_CC);
+ if (resolved_path) {
+ failure_retval = zend_hash_str_exists(&EG(included_files), resolved_path, (int)strlen(resolved_path));
+ } else {
+ resolved_path = Z_STRVAL_P(inc_filename);
+ }
+
+ if (failure_retval) {
+ /* do nothing, file already included */
+ } else if (SUCCESS == zend_stream_open(resolved_path, &file_handle TSRMLS_CC)) {
+
+ if (!file_handle.opened_path) {
+ file_handle.opened_path = estrdup(resolved_path);
+ }
+
+ if (zend_hash_str_add_empty_element(&EG(included_files), file_handle.opened_path, (int)strlen(file_handle.opened_path))) {
+ new_op_array = zend_compile_file(&file_handle, (opline->extended_value==ZEND_INCLUDE_ONCE?ZEND_INCLUDE:ZEND_REQUIRE) TSRMLS_CC);
+ zend_destroy_file_handle(&file_handle TSRMLS_CC);
+ } else {
+ zend_file_handle_dtor(&file_handle TSRMLS_CC);
+ failure_retval=1;
+ }
+ } else {
+ if (opline->extended_value == ZEND_INCLUDE_ONCE) {
+ zend_message_dispatcher(ZMSG_FAILED_INCLUDE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
+ } else {
+ zend_message_dispatcher(ZMSG_FAILED_REQUIRE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
+ }
+ }
+ if (resolved_path != Z_STRVAL_P(inc_filename)) {
+ efree(resolved_path);
+ }
+ }
+ break;
+ case ZEND_INCLUDE:
+ case ZEND_REQUIRE:
+ new_op_array = compile_filename(opline->extended_value, inc_filename TSRMLS_CC);
+ break;
+ case ZEND_EVAL: {
+ char *eval_desc = zend_make_compiled_string_description("eval()'d code" TSRMLS_CC);
+
+ new_op_array = zend_compile_string(inc_filename, eval_desc TSRMLS_CC);
+ efree(eval_desc);
+ }
+ break;
+ EMPTY_SWITCH_DEFAULT_CASE()
+ }
+ }
+ if (Z_TYPE(tmp_inc_filename) != IS_UNDEF) {
+ zend_string_release(Z_STR(tmp_inc_filename));
+ }
+ zval_ptr_dtor_nogc(free_op1);
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ HANDLE_EXCEPTION();
+ } else if (EXPECTED(new_op_array != NULL)) {
+ zval *return_value = NULL;
+ zend_execute_data *call;
+
+ if (RETURN_VALUE_USED(opline)) {
+ return_value = EX_VAR(opline->result.var);
+ }
+
+ new_op_array->scope = EG(scope); /* ??? */
+
+ call = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_CODE,
+ (zend_function*)new_op_array, 0, EX(called_scope), Z_OBJ(EX(This)), NULL TSRMLS_CC);
+
+ if (EX(symbol_table)) {
+ call->symbol_table = EX(symbol_table);
+ } else {
+ call->symbol_table = zend_rebuild_symbol_table(TSRMLS_C);
+ }
+
+ call->prev_execute_data = execute_data;
+ i_init_code_execute_data(call, new_op_array, return_value TSRMLS_CC);
+ if (EXPECTED(zend_execute_ex == execute_ex)) {
+ ZEND_VM_ENTER();
+ } else {
+ ZEND_ADD_CALL_FLAG(call, ZEND_CALL_TOP);
+ zend_execute_ex(call TSRMLS_CC);
+ }
+
+ destroy_op_array(new_op_array TSRMLS_CC);
+ efree_size(new_op_array, sizeof(zend_op_array));
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ zend_throw_exception_internal(NULL TSRMLS_CC);
+ HANDLE_EXCEPTION();
+ }
+
+ } else if (RETURN_VALUE_USED(opline)) {
+ ZVAL_BOOL(EX_VAR(opline->result.var), failure_retval);
+ }
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_ADD_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+
+ SAVE_OPLINE();
+ fast_add_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
+ opline->op2.zv TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_SUB_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+
+ SAVE_OPLINE();
+ fast_sub_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
+ opline->op2.zv TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_MUL_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+
+ SAVE_OPLINE();
+ fast_mul_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
+ opline->op2.zv TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_DIV_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+
+ SAVE_OPLINE();
+ fast_div_function(EX_VAR(opline->result.var),
+ _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
+ opline->op2.zv TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_IS_EQUAL_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+ zval *result = EX_VAR(opline->result.var);
+
+ SAVE_OPLINE();
+ fast_equal_function(result,
+ _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
+ opline->op2.zv TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL ZEND_IS_NOT_EQUAL_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
-
- zval *container;
- int result;
- zval *offset;
+ zend_free_op free_op1;
+ zval *result = EX_VAR(opline->result.var);
SAVE_OPLINE();
- container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
- offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
-
- if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
- if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
- result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
- } else {
- zend_error(E_NOTICE, "Trying to check property of non-object");
- result = 0;
- }
- if ((opline->extended_value & ZEND_ISSET) == 0) {
- result = !result;
- }
- } else {
- result = ((opline->extended_value & ZEND_ISSET) == 0);
- }
-
- ZVAL_BOOL(EX_VAR(opline->result.var), result);
+ fast_not_equal_function(result,
+ _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
+ opline->op2.zv TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_YIELD_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_IS_SMALLER_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zend_free_op free_op1;
+ zval *result = EX_VAR(opline->result.var);
- /* The generator object is stored in EX(return_value) */
- zend_generator *generator = (zend_generator *) EX(return_value);
+ SAVE_OPLINE();
+ fast_is_smaller_function(result,
+ _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
+ opline->op2.zv TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
- if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
- zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
- }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- /* Destroy the previously yielded value */
- zval_ptr_dtor(&generator->value);
+static int ZEND_FASTCALL ZEND_IS_SMALLER_OR_EQUAL_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+ zval *result = EX_VAR(opline->result.var);
- /* Destroy the previously yielded key */
- zval_ptr_dtor(&generator->key);
+ SAVE_OPLINE();
+ fast_is_smaller_or_equal_function(result,
+ _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
+ opline->op2.zv TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
- /* Set the new yielded value */
- if (IS_CV != IS_UNUSED) {
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_TMPVAR_CONST(int type, ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+ zval *varname;
+ zval *retval;
+ zend_string *name;
+ HashTable *target_symbol_table;
- if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
- /* Constants and temporary variables aren't yieldable by reference,
- * but we still allow them with a notice. */
- if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
- zval *value;
+ SAVE_OPLINE();
+ varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+ if ((IS_TMP_VAR|IS_VAR) == IS_CONST) {
+ name = Z_STR_P(varname);
+ } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
+ name = Z_STR_P(varname);
+ zend_string_addref(name);
+ } else {
+ name = zval_get_string(varname);
+ }
- value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
- ZVAL_COPY_VALUE(&generator->value, value);
- if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
+ if (IS_CONST != IS_UNUSED) {
+ zend_class_entry *ce;
- /* Temporary variables don't need ctor copying */
- if (IS_CV != IS_TMP_VAR) {
- zval_opt_copy_ctor(&generator->value);
- }
+ if (IS_CONST == IS_CONST) {
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
} else {
- zval *value_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-
- if (IS_CV == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
- zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
- }
-
- /* If a function call result is yielded and the function did
- * not return by reference we throw a notice. */
- if (IS_CV == IS_VAR &&
- (value_ptr == &EG(uninitialized_zval) ||
- (opline->extended_value == ZEND_RETURNS_FUNCTION &&
- !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
- zend_error(E_NOTICE, "Only variable references should be yielded by reference");
- } else {
- ZVAL_MAKE_REF(value_ptr);
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+ if (UNEXPECTED(ce == NULL)) {
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+ zend_string_release(name);
+ }
+ zval_ptr_dtor_nogc(free_op1);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
}
- ZVAL_COPY(&generator->value, value_ptr);
-
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
}
} else {
- zval *value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-
- /* Consts, temporary variables and references need copying */
- if (IS_CV == IS_CONST) {
- ZVAL_DUP(&generator->value, value);
- } else if (IS_CV == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&generator->value, value);
- } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(value)) {
- ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
-
- } else {
- ZVAL_COPY_VALUE(&generator->value, value);
- if (IS_CV == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+ ce = Z_CE_P(EX_VAR(opline->op2.var));
+ }
+ retval = zend_std_get_static_property(ce, name, 0, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
+ } else {
+ target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+ retval = zend_hash_find(target_symbol_table, name);
+ if (retval == NULL) {
+ switch (type) {
+ case BP_VAR_R:
+ case BP_VAR_UNSET:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_IS:
+ retval = &EG(uninitialized_zval);
+ break;
+ case BP_VAR_RW:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_W:
+ retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
+ break;
+ EMPTY_SWITCH_DEFAULT_CASE()
+ }
+ /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
+ } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
+ retval = Z_INDIRECT_P(retval);
+ if (Z_TYPE_P(retval) == IS_UNDEF) {
+ switch (type) {
+ case BP_VAR_R:
+ case BP_VAR_UNSET:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_IS:
+ retval = &EG(uninitialized_zval);
+ break;
+ case BP_VAR_RW:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_W:
+ ZVAL_NULL(retval);
+ break;
+ EMPTY_SWITCH_DEFAULT_CASE()
}
}
}
- } else {
- /* If no value was specified yield null */
- ZVAL_NULL(&generator->value);
- }
-
- /* Set the new yielded key */
- if (IS_CV != IS_UNUSED) {
-
- zval *key = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
-
- /* Consts, temporary variables and references need copying */
- if (IS_CV == IS_CONST) {
- ZVAL_DUP(&generator->key, key);
- } else if (IS_CV == IS_TMP_VAR) {
- ZVAL_COPY_VALUE(&generator->key, key);
- } else if ((IS_CV == IS_VAR || IS_CV == IS_CV) && Z_ISREF_P(key)) {
- ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
-
- } else {
- ZVAL_COPY_VALUE(&generator->key, key);
- if (IS_CV == IS_CV) {
- if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
+ if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
+ if (Z_CONSTANT_P(retval)) {
+ zval_update_constant(retval, 1 TSRMLS_CC);
}
+ } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
+ zval_ptr_dtor_nogc(free_op1);
}
+ }
- if (Z_TYPE(generator->key) == IS_LONG
- && Z_LVAL(generator->key) > generator->largest_used_integer_key
- ) {
- generator->largest_used_integer_key = Z_LVAL(generator->key);
- }
- } else {
- /* If no key was specified we use auto-increment keys */
- generator->largest_used_integer_key++;
- ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+ zend_string_release(name);
}
- if (RETURN_VALUE_USED(opline)) {
- /* If the return value of yield is used set the send
- * target and initialize it to NULL */
- generator->send_target = EX_VAR(opline->result.var);
- ZVAL_NULL(generator->send_target);
+ ZEND_ASSERT(retval != NULL);
+ if (type == BP_VAR_R || type == BP_VAR_IS) {
+ if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
+ ZVAL_UNREF(retval);
+ }
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
} else {
- generator->send_target = NULL;
+ ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
}
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
- /* We increment to the next op, so we are at the correct position when the
- * generator is resumed. */
- ZEND_VM_INC_OPCODE();
+static int ZEND_FASTCALL ZEND_FETCH_R_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_TMPVAR_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
- /* The GOTO VM uses a local opline variable. We need to set the opline
- * variable in execute_data so we don't resume at an old position. */
- SAVE_OPLINE();
+static int ZEND_FASTCALL ZEND_FETCH_W_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_TMPVAR_CONST(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
- ZEND_VM_RETURN();
+static int ZEND_FASTCALL ZEND_FETCH_RW_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_TMPVAR_CONST(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_POW_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_FUNC_ARG_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+ return zend_fetch_var_address_helper_SPEC_TMPVAR_CONST(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else {
+ return zend_fetch_var_address_helper_SPEC_TMPVAR_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
- SAVE_OPLINE();
- pow_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
-
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+static int ZEND_FASTCALL ZEND_FETCH_UNSET_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_TMPVAR_CONST(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_ASSIGN_POW_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_IS_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- return zend_binary_assign_op_helper_SPEC_CV_CV(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ return zend_fetch_var_address_helper_SPEC_TMPVAR_CONST(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_ADD_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_CASE_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
+ zend_free_op free_op1;
+ zval *result = EX_VAR(opline->result.var);
SAVE_OPLINE();
- fast_add_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ fast_equal_function(result,
+ _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
+ opline->op2.zv TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_SUB_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_UNSET_VAR_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
+ zval tmp, *varname;
+ HashTable *target_symbol_table;
+ zend_free_op free_op1;
SAVE_OPLINE();
- fast_sub_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ if ((IS_TMP_VAR|IS_VAR) == IS_CV &&
+ IS_CONST == IS_UNUSED &&
+ (opline->extended_value & ZEND_QUICK_SET)) {
+ zval *var = EX_VAR(opline->op1.var);
- zval_ptr_dtor_nogc(free_op2);
+ if (Z_REFCOUNTED_P(var)) {
+ zend_refcounted *garbage = Z_COUNTED_P(var);
+
+ if (!--GC_REFCOUNT(garbage)) {
+ ZVAL_UNDEF(var);
+ _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
+ } else {
+ GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
+ ZVAL_UNDEF(var);
+ }
+ } else {
+ ZVAL_UNDEF(var);
+ }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+
+ varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+
+ ZVAL_UNDEF(&tmp);
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
+ ZVAL_STR(&tmp, zval_get_string(varname));
+ varname = &tmp;
+ }
+
+ if (IS_CONST != IS_UNUSED) {
+ zend_class_entry *ce;
+
+ if (IS_CONST == IS_CONST) {
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ } else {
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+ zend_string_release(Z_STR(tmp));
+ }
+ zval_ptr_dtor_nogc(free_op1);
+ HANDLE_EXCEPTION();
+ }
+ if (UNEXPECTED(ce == NULL)) {
+ zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
+ }
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+ }
+ } else {
+ ce = Z_CE_P(EX_VAR(opline->op2.var));
+ }
+ zend_std_unset_static_property(ce, Z_STR_P(varname), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+ } else {
+ target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+ zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
+ }
+
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+ zend_string_release(Z_STR(tmp));
+ }
+ zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_MUL_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_VAR_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
+ zval *value;
SAVE_OPLINE();
- fast_mul_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ if ((IS_TMP_VAR|IS_VAR) == IS_CV &&
+ IS_CONST == IS_UNUSED &&
+ (opline->extended_value & ZEND_QUICK_SET)) {
+ value = EX_VAR(opline->op1.var);
+ if (opline->extended_value & ZEND_ISSET) {
+ ZVAL_BOOL(EX_VAR(opline->result.var),
+ Z_TYPE_P(value) > IS_NULL &&
+ (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+ } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+ ZVAL_BOOL(EX_VAR(opline->result.var),
+ !i_zend_is_true(value TSRMLS_CC));
+ CHECK_EXCEPTION();
+ }
+ ZEND_VM_NEXT_OPCODE();
+ } else {
+ zend_free_op free_op1;
+ zval tmp, *varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- zval_ptr_dtor_nogc(free_op2);
+ ZVAL_UNDEF(&tmp);
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
+ ZVAL_STR(&tmp, zval_get_string(varname));
+ varname = &tmp;
+ }
+
+ if (IS_CONST != IS_UNUSED) {
+ zend_class_entry *ce;
+
+ if (IS_CONST == IS_CONST) {
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ } else {
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+ if (UNEXPECTED(ce == NULL)) {
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+ }
+ } else {
+ ce = Z_CE_P(EX_VAR(opline->op2.var));
+ }
+ value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+ } else {
+ HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+ value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
+ }
+
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+ zend_string_release(Z_STR(tmp));
+ }
+ zval_ptr_dtor_nogc(free_op1);
+
+ if (opline->extended_value & ZEND_ISSET) {
+ ZVAL_BOOL(EX_VAR(opline->result.var),
+ value && Z_TYPE_P(value) > IS_NULL &&
+ (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+ } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+ ZVAL_BOOL(EX_VAR(opline->result.var),
+ !value || !i_zend_is_true(value TSRMLS_CC));
+ }
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+}
+
+static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_TMPVAR_VAR(int type, ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+ zval *varname;
+ zval *retval;
+ zend_string *name;
+ HashTable *target_symbol_table;
+
+ SAVE_OPLINE();
+ varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+
+ if ((IS_TMP_VAR|IS_VAR) == IS_CONST) {
+ name = Z_STR_P(varname);
+ } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
+ name = Z_STR_P(varname);
+ zend_string_addref(name);
+ } else {
+ name = zval_get_string(varname);
+ }
+
+ if (IS_VAR != IS_UNUSED) {
+ zend_class_entry *ce;
+
+ if (IS_VAR == IS_CONST) {
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ } else {
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+ if (UNEXPECTED(ce == NULL)) {
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+ zend_string_release(name);
+ }
+ zval_ptr_dtor_nogc(free_op1);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+ }
+ } else {
+ ce = Z_CE_P(EX_VAR(opline->op2.var));
+ }
+ retval = zend_std_get_static_property(ce, name, 0, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
+ } else {
+ target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+ retval = zend_hash_find(target_symbol_table, name);
+ if (retval == NULL) {
+ switch (type) {
+ case BP_VAR_R:
+ case BP_VAR_UNSET:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_IS:
+ retval = &EG(uninitialized_zval);
+ break;
+ case BP_VAR_RW:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_W:
+ retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
+ break;
+ EMPTY_SWITCH_DEFAULT_CASE()
+ }
+ /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
+ } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
+ retval = Z_INDIRECT_P(retval);
+ if (Z_TYPE_P(retval) == IS_UNDEF) {
+ switch (type) {
+ case BP_VAR_R:
+ case BP_VAR_UNSET:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_IS:
+ retval = &EG(uninitialized_zval);
+ break;
+ case BP_VAR_RW:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_W:
+ ZVAL_NULL(retval);
+ break;
+ EMPTY_SWITCH_DEFAULT_CASE()
+ }
+ }
+ }
+ if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
+ if (Z_CONSTANT_P(retval)) {
+ zval_update_constant(retval, 1 TSRMLS_CC);
+ }
+ } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
+ zval_ptr_dtor_nogc(free_op1);
+ }
+ }
+
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+ zend_string_release(name);
+ }
+
+ ZEND_ASSERT(retval != NULL);
+ if (type == BP_VAR_R || type == BP_VAR_IS) {
+ if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
+ ZVAL_UNREF(retval);
+ }
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ } else {
+ ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
+ }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_DIV_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_R_SPEC_TMPVAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- USE_OPLINE
- zend_free_op free_op2;
+ return zend_fetch_var_address_helper_SPEC_TMPVAR_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
- SAVE_OPLINE();
- fast_div_function(EX_VAR(opline->result.var),
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+static int ZEND_FASTCALL ZEND_FETCH_W_SPEC_TMPVAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_TMPVAR_VAR(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
- zval_ptr_dtor_nogc(free_op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+static int ZEND_FASTCALL ZEND_FETCH_RW_SPEC_TMPVAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_TMPVAR_VAR(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_IS_EQUAL_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_FUNC_ARG_SPEC_TMPVAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
- zval *result = EX_VAR(opline->result.var);
-
- SAVE_OPLINE();
- fast_equal_function(result,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+ return zend_fetch_var_address_helper_SPEC_TMPVAR_VAR(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else {
+ return zend_fetch_var_address_helper_SPEC_TMPVAR_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
}
-static int ZEND_FASTCALL ZEND_IS_NOT_EQUAL_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_UNSET_SPEC_TMPVAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- USE_OPLINE
- zend_free_op free_op2;
- zval *result = EX_VAR(opline->result.var);
-
- SAVE_OPLINE();
- fast_not_equal_function(result,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ return zend_fetch_var_address_helper_SPEC_TMPVAR_VAR(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
- zval_ptr_dtor_nogc(free_op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+static int ZEND_FASTCALL ZEND_FETCH_IS_SPEC_TMPVAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_TMPVAR_VAR(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_IS_SMALLER_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_UNSET_VAR_SPEC_TMPVAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op2;
- zval *result = EX_VAR(opline->result.var);
+ zval tmp, *varname;
+ HashTable *target_symbol_table;
+ zend_free_op free_op1;
SAVE_OPLINE();
- fast_is_smaller_function(result,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ if ((IS_TMP_VAR|IS_VAR) == IS_CV &&
+ IS_VAR == IS_UNUSED &&
+ (opline->extended_value & ZEND_QUICK_SET)) {
+ zval *var = EX_VAR(opline->op1.var);
- zval_ptr_dtor_nogc(free_op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ if (Z_REFCOUNTED_P(var)) {
+ zend_refcounted *garbage = Z_COUNTED_P(var);
-static int ZEND_FASTCALL ZEND_IS_SMALLER_OR_EQUAL_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op2;
- zval *result = EX_VAR(opline->result.var);
+ if (!--GC_REFCOUNT(garbage)) {
+ ZVAL_UNDEF(var);
+ _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
+ } else {
+ GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
+ ZVAL_UNDEF(var);
+ }
+ } else {
+ ZVAL_UNDEF(var);
+ }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
- SAVE_OPLINE();
- fast_is_smaller_or_equal_function(result,
- _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
- _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+ varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- zval_ptr_dtor_nogc(free_op2);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ ZVAL_UNDEF(&tmp);
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
+ ZVAL_STR(&tmp, zval_get_string(varname));
+ varname = &tmp;
+ }
-static int ZEND_FASTCALL ZEND_FREE_SPEC_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
+ if (IS_VAR != IS_UNUSED) {
+ zend_class_entry *ce;
- SAVE_OPLINE();
- zval_ptr_dtor_nogc(EX_VAR(opline->op1.var));
+ if (IS_VAR == IS_CONST) {
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ } else {
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+ zend_string_release(Z_STR(tmp));
+ }
+ zval_ptr_dtor_nogc(free_op1);
+ HANDLE_EXCEPTION();
+ }
+ if (UNEXPECTED(ce == NULL)) {
+ zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
+ }
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+ }
+ } else {
+ ce = Z_CE_P(EX_VAR(opline->op2.var));
+ }
+ zend_std_unset_static_property(ce, Z_STR_P(varname), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+ } else {
+ target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+ zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
+ }
+
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+ zend_string_release(Z_STR(tmp));
+ }
+ zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_ADD_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_VAR_SPEC_TMPVAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
+ zval *value;
SAVE_OPLINE();
- fast_add_function(EX_VAR(opline->result.var),
- _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
- opline->op2.zv TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
+ if ((IS_TMP_VAR|IS_VAR) == IS_CV &&
+ IS_VAR == IS_UNUSED &&
+ (opline->extended_value & ZEND_QUICK_SET)) {
+ value = EX_VAR(opline->op1.var);
+ if (opline->extended_value & ZEND_ISSET) {
+ ZVAL_BOOL(EX_VAR(opline->result.var),
+ Z_TYPE_P(value) > IS_NULL &&
+ (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+ } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+ ZVAL_BOOL(EX_VAR(opline->result.var),
+ !i_zend_is_true(value TSRMLS_CC));
+ CHECK_EXCEPTION();
+ }
+ ZEND_VM_NEXT_OPCODE();
+ } else {
+ zend_free_op free_op1;
+ zval tmp, *varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ ZVAL_UNDEF(&tmp);
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
+ ZVAL_STR(&tmp, zval_get_string(varname));
+ varname = &tmp;
+ }
-static int ZEND_FASTCALL ZEND_SUB_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
+ if (IS_VAR != IS_UNUSED) {
+ zend_class_entry *ce;
- SAVE_OPLINE();
- fast_sub_function(EX_VAR(opline->result.var),
- _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
- opline->op2.zv TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
+ if (IS_VAR == IS_CONST) {
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ } else {
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+ if (UNEXPECTED(ce == NULL)) {
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+ }
+ } else {
+ ce = Z_CE_P(EX_VAR(opline->op2.var));
+ }
+ value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+ } else {
+ HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+ value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
+ }
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+ zend_string_release(Z_STR(tmp));
+ }
+ zval_ptr_dtor_nogc(free_op1);
+
+ if (opline->extended_value & ZEND_ISSET) {
+ ZVAL_BOOL(EX_VAR(opline->result.var),
+ value && Z_TYPE_P(value) > IS_NULL &&
+ (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+ } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+ ZVAL_BOOL(EX_VAR(opline->result.var),
+ !value || !i_zend_is_true(value TSRMLS_CC));
+ }
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
}
-static int ZEND_FASTCALL ZEND_MUL_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_TMPVAR_UNUSED(int type, ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
zend_free_op free_op1;
+ zval *varname;
+ zval *retval;
+ zend_string *name;
+ HashTable *target_symbol_table;
SAVE_OPLINE();
- fast_mul_function(EX_VAR(opline->result.var),
- _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
- opline->op2.zv TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
+ varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
-}
+ if ((IS_TMP_VAR|IS_VAR) == IS_CONST) {
+ name = Z_STR_P(varname);
+ } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
+ name = Z_STR_P(varname);
+ zend_string_addref(name);
+ } else {
+ name = zval_get_string(varname);
+ }
-static int ZEND_FASTCALL ZEND_DIV_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
- USE_OPLINE
- zend_free_op free_op1;
+ if (IS_UNUSED != IS_UNUSED) {
+ zend_class_entry *ce;
- SAVE_OPLINE();
- fast_div_function(EX_VAR(opline->result.var),
- _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
- opline->op2.zv TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
+ if (IS_UNUSED == IS_CONST) {
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ } else {
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+ if (UNEXPECTED(ce == NULL)) {
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+ zend_string_release(name);
+ }
+ zval_ptr_dtor_nogc(free_op1);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+ }
+ } else {
+ ce = Z_CE_P(EX_VAR(opline->op2.var));
+ }
+ retval = zend_std_get_static_property(ce, name, 0, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+ zval_ptr_dtor_nogc(free_op1);
+ } else {
+ target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+ retval = zend_hash_find(target_symbol_table, name);
+ if (retval == NULL) {
+ switch (type) {
+ case BP_VAR_R:
+ case BP_VAR_UNSET:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_IS:
+ retval = &EG(uninitialized_zval);
+ break;
+ case BP_VAR_RW:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_W:
+ retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
+ break;
+ EMPTY_SWITCH_DEFAULT_CASE()
+ }
+ /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
+ } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
+ retval = Z_INDIRECT_P(retval);
+ if (Z_TYPE_P(retval) == IS_UNDEF) {
+ switch (type) {
+ case BP_VAR_R:
+ case BP_VAR_UNSET:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_IS:
+ retval = &EG(uninitialized_zval);
+ break;
+ case BP_VAR_RW:
+ zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+ /* break missing intentionally */
+ case BP_VAR_W:
+ ZVAL_NULL(retval);
+ break;
+ EMPTY_SWITCH_DEFAULT_CASE()
+ }
+ }
+ }
+ if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
+ if (Z_CONSTANT_P(retval)) {
+ zval_update_constant(retval, 1 TSRMLS_CC);
+ }
+ } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
+ zval_ptr_dtor_nogc(free_op1);
+ }
+ }
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+ zend_string_release(name);
+ }
+
+ ZEND_ASSERT(retval != NULL);
+ if (type == BP_VAR_R || type == BP_VAR_IS) {
+ if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
+ ZVAL_UNREF(retval);
+ }
+ ZVAL_COPY(EX_VAR(opline->result.var), retval);
+ } else {
+ ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
+ }
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_IS_EQUAL_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_R_SPEC_TMPVAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
- USE_OPLINE
- zend_free_op free_op1;
- zval *result = EX_VAR(opline->result.var);
+ return zend_fetch_var_address_helper_SPEC_TMPVAR_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
- SAVE_OPLINE();
- fast_equal_function(result,
- _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
- opline->op2.zv TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
+static int ZEND_FASTCALL ZEND_FETCH_W_SPEC_TMPVAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_TMPVAR_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+static int ZEND_FASTCALL ZEND_FETCH_RW_SPEC_TMPVAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_TMPVAR_UNUSED(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_IS_NOT_EQUAL_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_FUNC_ARG_SPEC_TMPVAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *result = EX_VAR(opline->result.var);
- SAVE_OPLINE();
- fast_not_equal_function(result,
- _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
- opline->op2.zv TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
+ if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+ return zend_fetch_var_address_helper_SPEC_TMPVAR_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ } else {
+ return zend_fetch_var_address_helper_SPEC_TMPVAR_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+ }
+}
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+static int ZEND_FASTCALL ZEND_FETCH_UNSET_SPEC_TMPVAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_TMPVAR_UNUSED(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
}
-static int ZEND_FASTCALL ZEND_IS_SMALLER_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_FETCH_IS_SPEC_TMPVAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ return zend_fetch_var_address_helper_SPEC_TMPVAR_UNUSED(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL ZEND_UNSET_VAR_SPEC_TMPVAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
+ zval tmp, *varname;
+ HashTable *target_symbol_table;
zend_free_op free_op1;
- zval *result = EX_VAR(opline->result.var);
SAVE_OPLINE();
- fast_is_smaller_function(result,
- _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
- opline->op2.zv TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
+ if ((IS_TMP_VAR|IS_VAR) == IS_CV &&
+ IS_UNUSED == IS_UNUSED &&
+ (opline->extended_value & ZEND_QUICK_SET)) {
+ zval *var = EX_VAR(opline->op1.var);
+
+ if (Z_REFCOUNTED_P(var)) {
+ zend_refcounted *garbage = Z_COUNTED_P(var);
+
+ if (!--GC_REFCOUNT(garbage)) {
+ ZVAL_UNDEF(var);
+ _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
+ } else {
+ GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
+ ZVAL_UNDEF(var);
+ }
+ } else {
+ ZVAL_UNDEF(var);
+ }
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+
+ varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+
+ ZVAL_UNDEF(&tmp);
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
+ ZVAL_STR(&tmp, zval_get_string(varname));
+ varname = &tmp;
+ }
+ if (IS_UNUSED != IS_UNUSED) {
+ zend_class_entry *ce;
+
+ if (IS_UNUSED == IS_CONST) {
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ } else {
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+ if (UNEXPECTED(EG(exception) != NULL)) {
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+ zend_string_release(Z_STR(tmp));
+ }
+ zval_ptr_dtor_nogc(free_op1);
+ HANDLE_EXCEPTION();
+ }
+ if (UNEXPECTED(ce == NULL)) {
+ zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
+ }
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+ }
+ } else {
+ ce = Z_CE_P(EX_VAR(opline->op2.var));
+ }
+ zend_std_unset_static_property(ce, Z_STR_P(varname), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+ } else {
+ target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+ zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
+ }
+
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+ zend_string_release(Z_STR(tmp));
+ }
+ zval_ptr_dtor_nogc(free_op1);
CHECK_EXCEPTION();
ZEND_VM_NEXT_OPCODE();
}
-static int ZEND_FASTCALL ZEND_IS_SMALLER_OR_EQUAL_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL ZEND_ISSET_ISEMPTY_VAR_SPEC_TMPVAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
- zend_free_op free_op1;
- zval *result = EX_VAR(opline->result.var);
+ zval *value;
SAVE_OPLINE();
- fast_is_smaller_or_equal_function(result,
- _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
- opline->op2.zv TSRMLS_CC);
- zval_ptr_dtor_nogc(free_op1);
+ if ((IS_TMP_VAR|IS_VAR) == IS_CV &&
+ IS_UNUSED == IS_UNUSED &&
+ (opline->extended_value & ZEND_QUICK_SET)) {
+ value = EX_VAR(opline->op1.var);
+ if (opline->extended_value & ZEND_ISSET) {
+ ZVAL_BOOL(EX_VAR(opline->result.var),
+ Z_TYPE_P(value) > IS_NULL &&
+ (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+ } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+ ZVAL_BOOL(EX_VAR(opline->result.var),
+ !i_zend_is_true(value TSRMLS_CC));
+ CHECK_EXCEPTION();
+ }
+ ZEND_VM_NEXT_OPCODE();
+ } else {
+ zend_free_op free_op1;
+ zval tmp, *varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
- CHECK_EXCEPTION();
- ZEND_VM_NEXT_OPCODE();
+ ZVAL_UNDEF(&tmp);
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
+ ZVAL_STR(&tmp, zval_get_string(varname));
+ varname = &tmp;
+ }
+
+ if (IS_UNUSED != IS_UNUSED) {
+ zend_class_entry *ce;
+
+ if (IS_UNUSED == IS_CONST) {
+ if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+ ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+ } else {
+ ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+ if (UNEXPECTED(ce == NULL)) {
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
+ CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+ }
+ } else {
+ ce = Z_CE_P(EX_VAR(opline->op2.var));
+ }
+ value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+ } else {
+ HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+ value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
+ }
+
+ if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+ zend_string_release(Z_STR(tmp));
+ }
+ zval_ptr_dtor_nogc(free_op1);
+
+ if (opline->extended_value & ZEND_ISSET) {
+ ZVAL_BOOL(EX_VAR(opline->result.var),
+ value && Z_TYPE_P(value) > IS_NULL &&
+ (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+ } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+ ZVAL_BOOL(EX_VAR(opline->result.var),
+ !value || !i_zend_is_true(value TSRMLS_CC));
+ }
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+ }
}
static int ZEND_FASTCALL ZEND_ADD_SPEC_TMPVAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
ZEND_VM_NEXT_OPCODE();
}
+static int ZEND_FASTCALL ZEND_CASE_SPEC_TMPVAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1;
+ zval *result = EX_VAR(opline->result.var);
+
+ SAVE_OPLINE();
+ fast_equal_function(result,
+ _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
static int ZEND_FASTCALL ZEND_ADD_SPEC_TMPVAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
USE_OPLINE
ZEND_VM_NEXT_OPCODE();
}
+static int ZEND_FASTCALL ZEND_CASE_SPEC_TMPVAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+ USE_OPLINE
+ zend_free_op free_op1, free_op2;
+ zval *result = EX_VAR(opline->result.var);
+
+ SAVE_OPLINE();
+ fast_equal_function(result,
+ _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
+ _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+
+ zval_ptr_dtor_nogc(free_op2);
+ CHECK_EXCEPTION();
+ ZEND_VM_NEXT_OPCODE();
+}
+
static int ZEND_FASTCALL ZEND_NULL_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
{
zend_error_noreturn(E_ERROR, "Invalid opcode %d/%d/%d.", OPLINE->opcode, OPLINE->op1_type, OPLINE->op2_type);
ZEND_JMPNZ_EX_SPEC_CV_HANDLER,
ZEND_JMPNZ_EX_SPEC_CV_HANDLER,
ZEND_CASE_SPEC_CONST_CONST_HANDLER,
- ZEND_CASE_SPEC_CONST_TMP_HANDLER,
- ZEND_CASE_SPEC_CONST_VAR_HANDLER,
+ ZEND_CASE_SPEC_CONST_TMPVAR_HANDLER,
+ ZEND_CASE_SPEC_CONST_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_CASE_SPEC_CONST_CV_HANDLER,
- ZEND_CASE_SPEC_TMP_CONST_HANDLER,
- ZEND_CASE_SPEC_TMP_TMP_HANDLER,
- ZEND_CASE_SPEC_TMP_VAR_HANDLER,
+ ZEND_CASE_SPEC_TMPVAR_CONST_HANDLER,
+ ZEND_CASE_SPEC_TMPVAR_TMPVAR_HANDLER,
+ ZEND_CASE_SPEC_TMPVAR_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_CASE_SPEC_TMP_CV_HANDLER,
- ZEND_CASE_SPEC_VAR_CONST_HANDLER,
- ZEND_CASE_SPEC_VAR_TMP_HANDLER,
- ZEND_CASE_SPEC_VAR_VAR_HANDLER,
+ ZEND_CASE_SPEC_TMPVAR_CV_HANDLER,
+ ZEND_CASE_SPEC_TMPVAR_CONST_HANDLER,
+ ZEND_CASE_SPEC_TMPVAR_TMPVAR_HANDLER,
+ ZEND_CASE_SPEC_TMPVAR_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_CASE_SPEC_VAR_CV_HANDLER,
+ ZEND_CASE_SPEC_TMPVAR_CV_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_CASE_SPEC_CV_CONST_HANDLER,
- ZEND_CASE_SPEC_CV_TMP_HANDLER,
- ZEND_CASE_SPEC_CV_VAR_HANDLER,
+ ZEND_CASE_SPEC_CV_TMPVAR_HANDLER,
+ ZEND_CASE_SPEC_CV_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_CASE_SPEC_CV_CV_HANDLER,
ZEND_NULL_HANDLER,
ZEND_BOOL_SPEC_CONST_HANDLER,
ZEND_BOOL_SPEC_CONST_HANDLER,
ZEND_BOOL_SPEC_CONST_HANDLER,
- ZEND_BOOL_SPEC_TMP_HANDLER,
- ZEND_BOOL_SPEC_TMP_HANDLER,
- ZEND_BOOL_SPEC_TMP_HANDLER,
- ZEND_BOOL_SPEC_TMP_HANDLER,
- ZEND_BOOL_SPEC_TMP_HANDLER,
- ZEND_BOOL_SPEC_VAR_HANDLER,
- ZEND_BOOL_SPEC_VAR_HANDLER,
- ZEND_BOOL_SPEC_VAR_HANDLER,
- ZEND_BOOL_SPEC_VAR_HANDLER,
- ZEND_BOOL_SPEC_VAR_HANDLER,
+ ZEND_BOOL_SPEC_TMPVAR_HANDLER,
+ ZEND_BOOL_SPEC_TMPVAR_HANDLER,
+ ZEND_BOOL_SPEC_TMPVAR_HANDLER,
+ ZEND_BOOL_SPEC_TMPVAR_HANDLER,
+ ZEND_BOOL_SPEC_TMPVAR_HANDLER,
+ ZEND_BOOL_SPEC_TMPVAR_HANDLER,
+ ZEND_BOOL_SPEC_TMPVAR_HANDLER,
+ ZEND_BOOL_SPEC_TMPVAR_HANDLER,
+ ZEND_BOOL_SPEC_TMPVAR_HANDLER,
+ ZEND_BOOL_SPEC_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_ADD_VAR_SPEC_TMP_TMP_HANDLER,
- ZEND_ADD_VAR_SPEC_TMP_VAR_HANDLER,
+ ZEND_ADD_VAR_SPEC_TMP_TMPVAR_HANDLER,
+ ZEND_ADD_VAR_SPEC_TMP_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_ADD_VAR_SPEC_TMP_CV_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_ADD_VAR_SPEC_UNUSED_TMP_HANDLER,
- ZEND_ADD_VAR_SPEC_UNUSED_VAR_HANDLER,
+ ZEND_ADD_VAR_SPEC_UNUSED_TMPVAR_HANDLER,
+ ZEND_ADD_VAR_SPEC_UNUSED_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_ADD_VAR_SPEC_UNUSED_CV_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_INIT_ARRAY_SPEC_CONST_CONST_HANDLER,
- ZEND_INIT_ARRAY_SPEC_CONST_TMP_HANDLER,
- ZEND_INIT_ARRAY_SPEC_CONST_VAR_HANDLER,
+ ZEND_INIT_ARRAY_SPEC_CONST_TMPVAR_HANDLER,
+ ZEND_INIT_ARRAY_SPEC_CONST_TMPVAR_HANDLER,
ZEND_INIT_ARRAY_SPEC_CONST_UNUSED_HANDLER,
ZEND_INIT_ARRAY_SPEC_CONST_CV_HANDLER,
ZEND_INIT_ARRAY_SPEC_TMP_CONST_HANDLER,
- ZEND_INIT_ARRAY_SPEC_TMP_TMP_HANDLER,
- ZEND_INIT_ARRAY_SPEC_TMP_VAR_HANDLER,
+ ZEND_INIT_ARRAY_SPEC_TMP_TMPVAR_HANDLER,
+ ZEND_INIT_ARRAY_SPEC_TMP_TMPVAR_HANDLER,
ZEND_INIT_ARRAY_SPEC_TMP_UNUSED_HANDLER,
ZEND_INIT_ARRAY_SPEC_TMP_CV_HANDLER,
ZEND_INIT_ARRAY_SPEC_VAR_CONST_HANDLER,
- ZEND_INIT_ARRAY_SPEC_VAR_TMP_HANDLER,
- ZEND_INIT_ARRAY_SPEC_VAR_VAR_HANDLER,
+ ZEND_INIT_ARRAY_SPEC_VAR_TMPVAR_HANDLER,
+ ZEND_INIT_ARRAY_SPEC_VAR_TMPVAR_HANDLER,
ZEND_INIT_ARRAY_SPEC_VAR_UNUSED_HANDLER,
ZEND_INIT_ARRAY_SPEC_VAR_CV_HANDLER,
ZEND_INIT_ARRAY_SPEC_UNUSED_CONST_HANDLER,
- ZEND_INIT_ARRAY_SPEC_UNUSED_TMP_HANDLER,
- ZEND_INIT_ARRAY_SPEC_UNUSED_VAR_HANDLER,
+ ZEND_INIT_ARRAY_SPEC_UNUSED_TMPVAR_HANDLER,
+ ZEND_INIT_ARRAY_SPEC_UNUSED_TMPVAR_HANDLER,
ZEND_INIT_ARRAY_SPEC_UNUSED_UNUSED_HANDLER,
ZEND_INIT_ARRAY_SPEC_UNUSED_CV_HANDLER,
ZEND_INIT_ARRAY_SPEC_CV_CONST_HANDLER,
- ZEND_INIT_ARRAY_SPEC_CV_TMP_HANDLER,
- ZEND_INIT_ARRAY_SPEC_CV_VAR_HANDLER,
+ ZEND_INIT_ARRAY_SPEC_CV_TMPVAR_HANDLER,
+ ZEND_INIT_ARRAY_SPEC_CV_TMPVAR_HANDLER,
ZEND_INIT_ARRAY_SPEC_CV_UNUSED_HANDLER,
ZEND_INIT_ARRAY_SPEC_CV_CV_HANDLER,
ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_CONST_HANDLER,
- ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_TMP_HANDLER,
- ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_VAR_HANDLER,
+ ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_TMPVAR_HANDLER,
+ ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_TMPVAR_HANDLER,
ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_UNUSED_HANDLER,
ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_CV_HANDLER,
ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_CONST_HANDLER,
- ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_TMP_HANDLER,
- ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_VAR_HANDLER,
+ ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_TMPVAR_HANDLER,
+ ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_TMPVAR_HANDLER,
ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_UNUSED_HANDLER,
ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_CV_HANDLER,
ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_CONST_HANDLER,
- ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_TMP_HANDLER,
- ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_VAR_HANDLER,
+ ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_TMPVAR_HANDLER,
+ ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_TMPVAR_HANDLER,
ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_UNUSED_HANDLER,
ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_CV_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CONST_HANDLER,
- ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_TMP_HANDLER,
- ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_VAR_HANDLER,
+ ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_TMPVAR_HANDLER,
+ ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_TMPVAR_HANDLER,
ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_UNUSED_HANDLER,
ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CV_HANDLER,
ZEND_INCLUDE_OR_EVAL_SPEC_CONST_HANDLER,
ZEND_INCLUDE_OR_EVAL_SPEC_CONST_HANDLER,
ZEND_INCLUDE_OR_EVAL_SPEC_CONST_HANDLER,
ZEND_INCLUDE_OR_EVAL_SPEC_CONST_HANDLER,
- ZEND_INCLUDE_OR_EVAL_SPEC_TMP_HANDLER,
- ZEND_INCLUDE_OR_EVAL_SPEC_TMP_HANDLER,
- ZEND_INCLUDE_OR_EVAL_SPEC_TMP_HANDLER,
- ZEND_INCLUDE_OR_EVAL_SPEC_TMP_HANDLER,
- ZEND_INCLUDE_OR_EVAL_SPEC_TMP_HANDLER,
- ZEND_INCLUDE_OR_EVAL_SPEC_VAR_HANDLER,
- ZEND_INCLUDE_OR_EVAL_SPEC_VAR_HANDLER,
- ZEND_INCLUDE_OR_EVAL_SPEC_VAR_HANDLER,
- ZEND_INCLUDE_OR_EVAL_SPEC_VAR_HANDLER,
- ZEND_INCLUDE_OR_EVAL_SPEC_VAR_HANDLER,
+ ZEND_INCLUDE_OR_EVAL_SPEC_TMPVAR_HANDLER,
+ ZEND_INCLUDE_OR_EVAL_SPEC_TMPVAR_HANDLER,
+ ZEND_INCLUDE_OR_EVAL_SPEC_TMPVAR_HANDLER,
+ ZEND_INCLUDE_OR_EVAL_SPEC_TMPVAR_HANDLER,
+ ZEND_INCLUDE_OR_EVAL_SPEC_TMPVAR_HANDLER,
+ ZEND_INCLUDE_OR_EVAL_SPEC_TMPVAR_HANDLER,
+ ZEND_INCLUDE_OR_EVAL_SPEC_TMPVAR_HANDLER,
+ ZEND_INCLUDE_OR_EVAL_SPEC_TMPVAR_HANDLER,
+ ZEND_INCLUDE_OR_EVAL_SPEC_TMPVAR_HANDLER,
+ ZEND_INCLUDE_OR_EVAL_SPEC_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_UNSET_VAR_SPEC_CONST_VAR_HANDLER,
ZEND_UNSET_VAR_SPEC_CONST_UNUSED_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_UNSET_VAR_SPEC_TMP_CONST_HANDLER,
+ ZEND_UNSET_VAR_SPEC_TMPVAR_CONST_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_UNSET_VAR_SPEC_TMP_VAR_HANDLER,
- ZEND_UNSET_VAR_SPEC_TMP_UNUSED_HANDLER,
+ ZEND_UNSET_VAR_SPEC_TMPVAR_VAR_HANDLER,
+ ZEND_UNSET_VAR_SPEC_TMPVAR_UNUSED_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_UNSET_VAR_SPEC_VAR_CONST_HANDLER,
+ ZEND_UNSET_VAR_SPEC_TMPVAR_CONST_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_UNSET_VAR_SPEC_VAR_VAR_HANDLER,
- ZEND_UNSET_VAR_SPEC_VAR_UNUSED_HANDLER,
+ ZEND_UNSET_VAR_SPEC_TMPVAR_VAR_HANDLER,
+ ZEND_UNSET_VAR_SPEC_TMPVAR_UNUSED_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_UNSET_DIM_SPEC_VAR_CONST_HANDLER,
- ZEND_UNSET_DIM_SPEC_VAR_TMP_HANDLER,
- ZEND_UNSET_DIM_SPEC_VAR_VAR_HANDLER,
+ ZEND_UNSET_DIM_SPEC_VAR_TMPVAR_HANDLER,
+ ZEND_UNSET_DIM_SPEC_VAR_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_UNSET_DIM_SPEC_VAR_CV_HANDLER,
ZEND_UNSET_DIM_SPEC_UNUSED_CONST_HANDLER,
- ZEND_UNSET_DIM_SPEC_UNUSED_TMP_HANDLER,
- ZEND_UNSET_DIM_SPEC_UNUSED_VAR_HANDLER,
+ ZEND_UNSET_DIM_SPEC_UNUSED_TMPVAR_HANDLER,
+ ZEND_UNSET_DIM_SPEC_UNUSED_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_UNSET_DIM_SPEC_UNUSED_CV_HANDLER,
ZEND_UNSET_DIM_SPEC_CV_CONST_HANDLER,
- ZEND_UNSET_DIM_SPEC_CV_TMP_HANDLER,
- ZEND_UNSET_DIM_SPEC_CV_VAR_HANDLER,
+ ZEND_UNSET_DIM_SPEC_CV_TMPVAR_HANDLER,
+ ZEND_UNSET_DIM_SPEC_CV_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_UNSET_DIM_SPEC_CV_CV_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_UNSET_OBJ_SPEC_VAR_CONST_HANDLER,
- ZEND_UNSET_OBJ_SPEC_VAR_TMP_HANDLER,
- ZEND_UNSET_OBJ_SPEC_VAR_VAR_HANDLER,
+ ZEND_UNSET_OBJ_SPEC_VAR_TMPVAR_HANDLER,
+ ZEND_UNSET_OBJ_SPEC_VAR_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_UNSET_OBJ_SPEC_VAR_CV_HANDLER,
ZEND_UNSET_OBJ_SPEC_UNUSED_CONST_HANDLER,
- ZEND_UNSET_OBJ_SPEC_UNUSED_TMP_HANDLER,
- ZEND_UNSET_OBJ_SPEC_UNUSED_VAR_HANDLER,
+ ZEND_UNSET_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
+ ZEND_UNSET_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_UNSET_OBJ_SPEC_UNUSED_CV_HANDLER,
ZEND_UNSET_OBJ_SPEC_CV_CONST_HANDLER,
- ZEND_UNSET_OBJ_SPEC_CV_TMP_HANDLER,
- ZEND_UNSET_OBJ_SPEC_CV_VAR_HANDLER,
+ ZEND_UNSET_OBJ_SPEC_CV_TMPVAR_HANDLER,
+ ZEND_UNSET_OBJ_SPEC_CV_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_UNSET_OBJ_SPEC_CV_CV_HANDLER,
ZEND_FE_RESET_SPEC_CONST_HANDLER,
ZEND_FETCH_R_SPEC_CONST_VAR_HANDLER,
ZEND_FETCH_R_SPEC_CONST_UNUSED_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_FETCH_R_SPEC_TMP_CONST_HANDLER,
+ ZEND_FETCH_R_SPEC_TMPVAR_CONST_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_FETCH_R_SPEC_TMP_VAR_HANDLER,
- ZEND_FETCH_R_SPEC_TMP_UNUSED_HANDLER,
+ ZEND_FETCH_R_SPEC_TMPVAR_VAR_HANDLER,
+ ZEND_FETCH_R_SPEC_TMPVAR_UNUSED_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_FETCH_R_SPEC_VAR_CONST_HANDLER,
+ ZEND_FETCH_R_SPEC_TMPVAR_CONST_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_FETCH_R_SPEC_VAR_VAR_HANDLER,
- ZEND_FETCH_R_SPEC_VAR_UNUSED_HANDLER,
+ ZEND_FETCH_R_SPEC_TMPVAR_VAR_HANDLER,
+ ZEND_FETCH_R_SPEC_TMPVAR_UNUSED_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_DIM_R_SPEC_CV_CV_HANDLER,
ZEND_FETCH_OBJ_R_SPEC_CONST_CONST_HANDLER,
- ZEND_FETCH_OBJ_R_SPEC_CONST_TMP_HANDLER,
- ZEND_FETCH_OBJ_R_SPEC_CONST_VAR_HANDLER,
+ ZEND_FETCH_OBJ_R_SPEC_CONST_TMPVAR_HANDLER,
+ ZEND_FETCH_OBJ_R_SPEC_CONST_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_R_SPEC_CONST_CV_HANDLER,
ZEND_FETCH_OBJ_R_SPEC_TMP_CONST_HANDLER,
- ZEND_FETCH_OBJ_R_SPEC_TMP_TMP_HANDLER,
- ZEND_FETCH_OBJ_R_SPEC_TMP_VAR_HANDLER,
+ ZEND_FETCH_OBJ_R_SPEC_TMP_TMPVAR_HANDLER,
+ ZEND_FETCH_OBJ_R_SPEC_TMP_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_R_SPEC_TMP_CV_HANDLER,
ZEND_FETCH_OBJ_R_SPEC_VAR_CONST_HANDLER,
- ZEND_FETCH_OBJ_R_SPEC_VAR_TMP_HANDLER,
- ZEND_FETCH_OBJ_R_SPEC_VAR_VAR_HANDLER,
+ ZEND_FETCH_OBJ_R_SPEC_VAR_TMPVAR_HANDLER,
+ ZEND_FETCH_OBJ_R_SPEC_VAR_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_R_SPEC_VAR_CV_HANDLER,
ZEND_FETCH_OBJ_R_SPEC_UNUSED_CONST_HANDLER,
- ZEND_FETCH_OBJ_R_SPEC_UNUSED_TMP_HANDLER,
- ZEND_FETCH_OBJ_R_SPEC_UNUSED_VAR_HANDLER,
+ ZEND_FETCH_OBJ_R_SPEC_UNUSED_TMPVAR_HANDLER,
+ ZEND_FETCH_OBJ_R_SPEC_UNUSED_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_R_SPEC_UNUSED_CV_HANDLER,
ZEND_FETCH_OBJ_R_SPEC_CV_CONST_HANDLER,
- ZEND_FETCH_OBJ_R_SPEC_CV_TMP_HANDLER,
- ZEND_FETCH_OBJ_R_SPEC_CV_VAR_HANDLER,
+ ZEND_FETCH_OBJ_R_SPEC_CV_TMPVAR_HANDLER,
+ ZEND_FETCH_OBJ_R_SPEC_CV_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_R_SPEC_CV_CV_HANDLER,
ZEND_FETCH_W_SPEC_CONST_CONST_HANDLER,
ZEND_FETCH_W_SPEC_CONST_VAR_HANDLER,
ZEND_FETCH_W_SPEC_CONST_UNUSED_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_FETCH_W_SPEC_TMP_CONST_HANDLER,
+ ZEND_FETCH_W_SPEC_TMPVAR_CONST_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_FETCH_W_SPEC_TMP_VAR_HANDLER,
- ZEND_FETCH_W_SPEC_TMP_UNUSED_HANDLER,
+ ZEND_FETCH_W_SPEC_TMPVAR_VAR_HANDLER,
+ ZEND_FETCH_W_SPEC_TMPVAR_UNUSED_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_FETCH_W_SPEC_VAR_CONST_HANDLER,
+ ZEND_FETCH_W_SPEC_TMPVAR_CONST_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_FETCH_W_SPEC_VAR_VAR_HANDLER,
- ZEND_FETCH_W_SPEC_VAR_UNUSED_HANDLER,
+ ZEND_FETCH_W_SPEC_TMPVAR_VAR_HANDLER,
+ ZEND_FETCH_W_SPEC_TMPVAR_UNUSED_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_W_SPEC_VAR_CONST_HANDLER,
- ZEND_FETCH_OBJ_W_SPEC_VAR_TMP_HANDLER,
- ZEND_FETCH_OBJ_W_SPEC_VAR_VAR_HANDLER,
+ ZEND_FETCH_OBJ_W_SPEC_VAR_TMPVAR_HANDLER,
+ ZEND_FETCH_OBJ_W_SPEC_VAR_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_W_SPEC_VAR_CV_HANDLER,
ZEND_FETCH_OBJ_W_SPEC_UNUSED_CONST_HANDLER,
- ZEND_FETCH_OBJ_W_SPEC_UNUSED_TMP_HANDLER,
- ZEND_FETCH_OBJ_W_SPEC_UNUSED_VAR_HANDLER,
+ ZEND_FETCH_OBJ_W_SPEC_UNUSED_TMPVAR_HANDLER,
+ ZEND_FETCH_OBJ_W_SPEC_UNUSED_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_W_SPEC_UNUSED_CV_HANDLER,
ZEND_FETCH_OBJ_W_SPEC_CV_CONST_HANDLER,
- ZEND_FETCH_OBJ_W_SPEC_CV_TMP_HANDLER,
- ZEND_FETCH_OBJ_W_SPEC_CV_VAR_HANDLER,
+ ZEND_FETCH_OBJ_W_SPEC_CV_TMPVAR_HANDLER,
+ ZEND_FETCH_OBJ_W_SPEC_CV_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_W_SPEC_CV_CV_HANDLER,
ZEND_FETCH_RW_SPEC_CONST_CONST_HANDLER,
ZEND_FETCH_RW_SPEC_CONST_VAR_HANDLER,
ZEND_FETCH_RW_SPEC_CONST_UNUSED_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_FETCH_RW_SPEC_TMP_CONST_HANDLER,
+ ZEND_FETCH_RW_SPEC_TMPVAR_CONST_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_FETCH_RW_SPEC_TMP_VAR_HANDLER,
- ZEND_FETCH_RW_SPEC_TMP_UNUSED_HANDLER,
+ ZEND_FETCH_RW_SPEC_TMPVAR_VAR_HANDLER,
+ ZEND_FETCH_RW_SPEC_TMPVAR_UNUSED_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_FETCH_RW_SPEC_VAR_CONST_HANDLER,
+ ZEND_FETCH_RW_SPEC_TMPVAR_CONST_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_FETCH_RW_SPEC_VAR_VAR_HANDLER,
- ZEND_FETCH_RW_SPEC_VAR_UNUSED_HANDLER,
+ ZEND_FETCH_RW_SPEC_TMPVAR_VAR_HANDLER,
+ ZEND_FETCH_RW_SPEC_TMPVAR_UNUSED_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_RW_SPEC_VAR_CONST_HANDLER,
- ZEND_FETCH_OBJ_RW_SPEC_VAR_TMP_HANDLER,
- ZEND_FETCH_OBJ_RW_SPEC_VAR_VAR_HANDLER,
+ ZEND_FETCH_OBJ_RW_SPEC_VAR_TMPVAR_HANDLER,
+ ZEND_FETCH_OBJ_RW_SPEC_VAR_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_RW_SPEC_VAR_CV_HANDLER,
ZEND_FETCH_OBJ_RW_SPEC_UNUSED_CONST_HANDLER,
- ZEND_FETCH_OBJ_RW_SPEC_UNUSED_TMP_HANDLER,
- ZEND_FETCH_OBJ_RW_SPEC_UNUSED_VAR_HANDLER,
+ ZEND_FETCH_OBJ_RW_SPEC_UNUSED_TMPVAR_HANDLER,
+ ZEND_FETCH_OBJ_RW_SPEC_UNUSED_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_RW_SPEC_UNUSED_CV_HANDLER,
ZEND_FETCH_OBJ_RW_SPEC_CV_CONST_HANDLER,
- ZEND_FETCH_OBJ_RW_SPEC_CV_TMP_HANDLER,
- ZEND_FETCH_OBJ_RW_SPEC_CV_VAR_HANDLER,
+ ZEND_FETCH_OBJ_RW_SPEC_CV_TMPVAR_HANDLER,
+ ZEND_FETCH_OBJ_RW_SPEC_CV_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_RW_SPEC_CV_CV_HANDLER,
ZEND_FETCH_IS_SPEC_CONST_CONST_HANDLER,
ZEND_FETCH_IS_SPEC_CONST_VAR_HANDLER,
ZEND_FETCH_IS_SPEC_CONST_UNUSED_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_FETCH_IS_SPEC_TMP_CONST_HANDLER,
+ ZEND_FETCH_IS_SPEC_TMPVAR_CONST_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_FETCH_IS_SPEC_TMP_VAR_HANDLER,
- ZEND_FETCH_IS_SPEC_TMP_UNUSED_HANDLER,
+ ZEND_FETCH_IS_SPEC_TMPVAR_VAR_HANDLER,
+ ZEND_FETCH_IS_SPEC_TMPVAR_UNUSED_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_FETCH_IS_SPEC_VAR_CONST_HANDLER,
+ ZEND_FETCH_IS_SPEC_TMPVAR_CONST_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_FETCH_IS_SPEC_VAR_VAR_HANDLER,
- ZEND_FETCH_IS_SPEC_VAR_UNUSED_HANDLER,
+ ZEND_FETCH_IS_SPEC_TMPVAR_VAR_HANDLER,
+ ZEND_FETCH_IS_SPEC_TMPVAR_UNUSED_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_DIM_IS_SPEC_CV_CV_HANDLER,
ZEND_FETCH_OBJ_IS_SPEC_CONST_CONST_HANDLER,
- ZEND_FETCH_OBJ_IS_SPEC_CONST_TMP_HANDLER,
- ZEND_FETCH_OBJ_IS_SPEC_CONST_VAR_HANDLER,
+ ZEND_FETCH_OBJ_IS_SPEC_CONST_TMPVAR_HANDLER,
+ ZEND_FETCH_OBJ_IS_SPEC_CONST_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_IS_SPEC_CONST_CV_HANDLER,
ZEND_FETCH_OBJ_IS_SPEC_TMP_CONST_HANDLER,
- ZEND_FETCH_OBJ_IS_SPEC_TMP_TMP_HANDLER,
- ZEND_FETCH_OBJ_IS_SPEC_TMP_VAR_HANDLER,
+ ZEND_FETCH_OBJ_IS_SPEC_TMP_TMPVAR_HANDLER,
+ ZEND_FETCH_OBJ_IS_SPEC_TMP_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_IS_SPEC_TMP_CV_HANDLER,
ZEND_FETCH_OBJ_IS_SPEC_VAR_CONST_HANDLER,
- ZEND_FETCH_OBJ_IS_SPEC_VAR_TMP_HANDLER,
- ZEND_FETCH_OBJ_IS_SPEC_VAR_VAR_HANDLER,
+ ZEND_FETCH_OBJ_IS_SPEC_VAR_TMPVAR_HANDLER,
+ ZEND_FETCH_OBJ_IS_SPEC_VAR_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_IS_SPEC_VAR_CV_HANDLER,
ZEND_FETCH_OBJ_IS_SPEC_UNUSED_CONST_HANDLER,
- ZEND_FETCH_OBJ_IS_SPEC_UNUSED_TMP_HANDLER,
- ZEND_FETCH_OBJ_IS_SPEC_UNUSED_VAR_HANDLER,
+ ZEND_FETCH_OBJ_IS_SPEC_UNUSED_TMPVAR_HANDLER,
+ ZEND_FETCH_OBJ_IS_SPEC_UNUSED_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_IS_SPEC_UNUSED_CV_HANDLER,
ZEND_FETCH_OBJ_IS_SPEC_CV_CONST_HANDLER,
- ZEND_FETCH_OBJ_IS_SPEC_CV_TMP_HANDLER,
- ZEND_FETCH_OBJ_IS_SPEC_CV_VAR_HANDLER,
+ ZEND_FETCH_OBJ_IS_SPEC_CV_TMPVAR_HANDLER,
+ ZEND_FETCH_OBJ_IS_SPEC_CV_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_IS_SPEC_CV_CV_HANDLER,
ZEND_FETCH_FUNC_ARG_SPEC_CONST_CONST_HANDLER,
ZEND_FETCH_FUNC_ARG_SPEC_CONST_VAR_HANDLER,
ZEND_FETCH_FUNC_ARG_SPEC_CONST_UNUSED_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_FETCH_FUNC_ARG_SPEC_TMP_CONST_HANDLER,
+ ZEND_FETCH_FUNC_ARG_SPEC_TMPVAR_CONST_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_FETCH_FUNC_ARG_SPEC_TMP_VAR_HANDLER,
- ZEND_FETCH_FUNC_ARG_SPEC_TMP_UNUSED_HANDLER,
+ ZEND_FETCH_FUNC_ARG_SPEC_TMPVAR_VAR_HANDLER,
+ ZEND_FETCH_FUNC_ARG_SPEC_TMPVAR_UNUSED_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_FETCH_FUNC_ARG_SPEC_VAR_CONST_HANDLER,
+ ZEND_FETCH_FUNC_ARG_SPEC_TMPVAR_CONST_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_FETCH_FUNC_ARG_SPEC_VAR_VAR_HANDLER,
- ZEND_FETCH_FUNC_ARG_SPEC_VAR_UNUSED_HANDLER,
+ ZEND_FETCH_FUNC_ARG_SPEC_TMPVAR_VAR_HANDLER,
+ ZEND_FETCH_FUNC_ARG_SPEC_TMPVAR_UNUSED_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_UNUSED_HANDLER,
ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_CV_HANDLER,
ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CONST_CONST_HANDLER,
- ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CONST_TMP_HANDLER,
- ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CONST_VAR_HANDLER,
+ ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CONST_TMPVAR_HANDLER,
+ ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CONST_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CONST_CV_HANDLER,
ZEND_FETCH_OBJ_FUNC_ARG_SPEC_TMP_CONST_HANDLER,
- ZEND_FETCH_OBJ_FUNC_ARG_SPEC_TMP_TMP_HANDLER,
- ZEND_FETCH_OBJ_FUNC_ARG_SPEC_TMP_VAR_HANDLER,
+ ZEND_FETCH_OBJ_FUNC_ARG_SPEC_TMP_TMPVAR_HANDLER,
+ ZEND_FETCH_OBJ_FUNC_ARG_SPEC_TMP_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_FUNC_ARG_SPEC_TMP_CV_HANDLER,
ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_CONST_HANDLER,
- ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_TMP_HANDLER,
- ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_VAR_HANDLER,
+ ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_TMPVAR_HANDLER,
+ ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_CV_HANDLER,
ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_CONST_HANDLER,
- ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_TMP_HANDLER,
- ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_VAR_HANDLER,
+ ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_TMPVAR_HANDLER,
+ ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_CV_HANDLER,
ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_CONST_HANDLER,
- ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_TMP_HANDLER,
- ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_VAR_HANDLER,
+ ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_TMPVAR_HANDLER,
+ ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_CV_HANDLER,
ZEND_FETCH_UNSET_SPEC_CONST_CONST_HANDLER,
ZEND_FETCH_UNSET_SPEC_CONST_VAR_HANDLER,
ZEND_FETCH_UNSET_SPEC_CONST_UNUSED_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_FETCH_UNSET_SPEC_TMP_CONST_HANDLER,
+ ZEND_FETCH_UNSET_SPEC_TMPVAR_CONST_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_FETCH_UNSET_SPEC_TMP_VAR_HANDLER,
- ZEND_FETCH_UNSET_SPEC_TMP_UNUSED_HANDLER,
+ ZEND_FETCH_UNSET_SPEC_TMPVAR_VAR_HANDLER,
+ ZEND_FETCH_UNSET_SPEC_TMPVAR_UNUSED_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_FETCH_UNSET_SPEC_VAR_CONST_HANDLER,
+ ZEND_FETCH_UNSET_SPEC_TMPVAR_CONST_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_FETCH_UNSET_SPEC_VAR_VAR_HANDLER,
- ZEND_FETCH_UNSET_SPEC_VAR_UNUSED_HANDLER,
+ ZEND_FETCH_UNSET_SPEC_TMPVAR_VAR_HANDLER,
+ ZEND_FETCH_UNSET_SPEC_TMPVAR_UNUSED_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_UNSET_SPEC_VAR_CONST_HANDLER,
- ZEND_FETCH_OBJ_UNSET_SPEC_VAR_TMP_HANDLER,
- ZEND_FETCH_OBJ_UNSET_SPEC_VAR_VAR_HANDLER,
+ ZEND_FETCH_OBJ_UNSET_SPEC_VAR_TMPVAR_HANDLER,
+ ZEND_FETCH_OBJ_UNSET_SPEC_VAR_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_UNSET_SPEC_VAR_CV_HANDLER,
ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_CONST_HANDLER,
- ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_TMP_HANDLER,
- ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_VAR_HANDLER,
+ ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_TMPVAR_HANDLER,
+ ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_CV_HANDLER,
ZEND_FETCH_OBJ_UNSET_SPEC_CV_CONST_HANDLER,
- ZEND_FETCH_OBJ_UNSET_SPEC_CV_TMP_HANDLER,
- ZEND_FETCH_OBJ_UNSET_SPEC_CV_VAR_HANDLER,
+ ZEND_FETCH_OBJ_UNSET_SPEC_CV_TMPVAR_HANDLER,
+ ZEND_FETCH_OBJ_UNSET_SPEC_CV_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_FETCH_OBJ_UNSET_SPEC_CV_CV_HANDLER,
ZEND_FETCH_LIST_SPEC_CONST_CONST_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_INIT_METHOD_CALL_SPEC_TMP_CONST_HANDLER,
- ZEND_INIT_METHOD_CALL_SPEC_TMP_TMP_HANDLER,
- ZEND_INIT_METHOD_CALL_SPEC_TMP_VAR_HANDLER,
+ ZEND_INIT_METHOD_CALL_SPEC_TMP_TMPVAR_HANDLER,
+ ZEND_INIT_METHOD_CALL_SPEC_TMP_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_INIT_METHOD_CALL_SPEC_TMP_CV_HANDLER,
ZEND_INIT_METHOD_CALL_SPEC_VAR_CONST_HANDLER,
- ZEND_INIT_METHOD_CALL_SPEC_VAR_TMP_HANDLER,
- ZEND_INIT_METHOD_CALL_SPEC_VAR_VAR_HANDLER,
+ ZEND_INIT_METHOD_CALL_SPEC_VAR_TMPVAR_HANDLER,
+ ZEND_INIT_METHOD_CALL_SPEC_VAR_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_INIT_METHOD_CALL_SPEC_VAR_CV_HANDLER,
ZEND_INIT_METHOD_CALL_SPEC_UNUSED_CONST_HANDLER,
- ZEND_INIT_METHOD_CALL_SPEC_UNUSED_TMP_HANDLER,
- ZEND_INIT_METHOD_CALL_SPEC_UNUSED_VAR_HANDLER,
+ ZEND_INIT_METHOD_CALL_SPEC_UNUSED_TMPVAR_HANDLER,
+ ZEND_INIT_METHOD_CALL_SPEC_UNUSED_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_INIT_METHOD_CALL_SPEC_UNUSED_CV_HANDLER,
ZEND_INIT_METHOD_CALL_SPEC_CV_CONST_HANDLER,
- ZEND_INIT_METHOD_CALL_SPEC_CV_TMP_HANDLER,
- ZEND_INIT_METHOD_CALL_SPEC_CV_VAR_HANDLER,
+ ZEND_INIT_METHOD_CALL_SPEC_CV_TMPVAR_HANDLER,
+ ZEND_INIT_METHOD_CALL_SPEC_CV_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_INIT_METHOD_CALL_SPEC_CV_CV_HANDLER,
ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_CONST_HANDLER,
- ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_TMP_HANDLER,
- ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_VAR_HANDLER,
+ ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_TMPVAR_HANDLER,
+ ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_TMPVAR_HANDLER,
ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_UNUSED_HANDLER,
ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_CV_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_CONST_HANDLER,
- ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_TMP_HANDLER,
- ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_VAR_HANDLER,
+ ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_TMPVAR_HANDLER,
+ ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_TMPVAR_HANDLER,
ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_UNUSED_HANDLER,
ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_CV_HANDLER,
ZEND_NULL_HANDLER,
ZEND_ISSET_ISEMPTY_VAR_SPEC_CONST_VAR_HANDLER,
ZEND_ISSET_ISEMPTY_VAR_SPEC_CONST_UNUSED_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_ISSET_ISEMPTY_VAR_SPEC_TMP_CONST_HANDLER,
+ ZEND_ISSET_ISEMPTY_VAR_SPEC_TMPVAR_CONST_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_ISSET_ISEMPTY_VAR_SPEC_TMP_VAR_HANDLER,
- ZEND_ISSET_ISEMPTY_VAR_SPEC_TMP_UNUSED_HANDLER,
+ ZEND_ISSET_ISEMPTY_VAR_SPEC_TMPVAR_VAR_HANDLER,
+ ZEND_ISSET_ISEMPTY_VAR_SPEC_TMPVAR_UNUSED_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_ISSET_ISEMPTY_VAR_SPEC_VAR_CONST_HANDLER,
+ ZEND_ISSET_ISEMPTY_VAR_SPEC_TMPVAR_CONST_HANDLER,
ZEND_NULL_HANDLER,
- ZEND_ISSET_ISEMPTY_VAR_SPEC_VAR_VAR_HANDLER,
- ZEND_ISSET_ISEMPTY_VAR_SPEC_VAR_UNUSED_HANDLER,
+ ZEND_ISSET_ISEMPTY_VAR_SPEC_TMPVAR_VAR_HANDLER,
+ ZEND_ISSET_ISEMPTY_VAR_SPEC_TMPVAR_UNUSED_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_ISSET_ISEMPTY_VAR_SPEC_CV_UNUSED_HANDLER,
ZEND_NULL_HANDLER,
ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CONST_CONST_HANDLER,
- ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CONST_TMP_HANDLER,
- ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CONST_VAR_HANDLER,
+ ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CONST_TMPVAR_HANDLER,
+ ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CONST_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CONST_CV_HANDLER,
ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_CONST_HANDLER,
- ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_TMP_HANDLER,
- ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_VAR_HANDLER,
+ ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_TMPVAR_HANDLER,
+ ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_CV_HANDLER,
ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_CONST_HANDLER,
- ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_TMP_HANDLER,
- ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_VAR_HANDLER,
+ ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_TMPVAR_HANDLER,
+ ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_CV_HANDLER,
ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_CONST_HANDLER,
- ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_TMP_HANDLER,
- ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_VAR_HANDLER,
+ ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
+ ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_CV_HANDLER,
ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_CONST_HANDLER,
- ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_TMP_HANDLER,
- ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_VAR_HANDLER,
+ ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_TMPVAR_HANDLER,
+ ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_CV_HANDLER,
ZEND_SEND_VAL_EX_SPEC_CONST_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_PRE_INC_OBJ_SPEC_VAR_CONST_HANDLER,
- ZEND_PRE_INC_OBJ_SPEC_VAR_TMP_HANDLER,
- ZEND_PRE_INC_OBJ_SPEC_VAR_VAR_HANDLER,
+ ZEND_PRE_INC_OBJ_SPEC_VAR_TMPVAR_HANDLER,
+ ZEND_PRE_INC_OBJ_SPEC_VAR_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_PRE_INC_OBJ_SPEC_VAR_CV_HANDLER,
ZEND_PRE_INC_OBJ_SPEC_UNUSED_CONST_HANDLER,
- ZEND_PRE_INC_OBJ_SPEC_UNUSED_TMP_HANDLER,
- ZEND_PRE_INC_OBJ_SPEC_UNUSED_VAR_HANDLER,
+ ZEND_PRE_INC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
+ ZEND_PRE_INC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_PRE_INC_OBJ_SPEC_UNUSED_CV_HANDLER,
ZEND_PRE_INC_OBJ_SPEC_CV_CONST_HANDLER,
- ZEND_PRE_INC_OBJ_SPEC_CV_TMP_HANDLER,
- ZEND_PRE_INC_OBJ_SPEC_CV_VAR_HANDLER,
+ ZEND_PRE_INC_OBJ_SPEC_CV_TMPVAR_HANDLER,
+ ZEND_PRE_INC_OBJ_SPEC_CV_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_PRE_INC_OBJ_SPEC_CV_CV_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_PRE_DEC_OBJ_SPEC_VAR_CONST_HANDLER,
- ZEND_PRE_DEC_OBJ_SPEC_VAR_TMP_HANDLER,
- ZEND_PRE_DEC_OBJ_SPEC_VAR_VAR_HANDLER,
+ ZEND_PRE_DEC_OBJ_SPEC_VAR_TMPVAR_HANDLER,
+ ZEND_PRE_DEC_OBJ_SPEC_VAR_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_PRE_DEC_OBJ_SPEC_VAR_CV_HANDLER,
ZEND_PRE_DEC_OBJ_SPEC_UNUSED_CONST_HANDLER,
- ZEND_PRE_DEC_OBJ_SPEC_UNUSED_TMP_HANDLER,
- ZEND_PRE_DEC_OBJ_SPEC_UNUSED_VAR_HANDLER,
+ ZEND_PRE_DEC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
+ ZEND_PRE_DEC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_PRE_DEC_OBJ_SPEC_UNUSED_CV_HANDLER,
ZEND_PRE_DEC_OBJ_SPEC_CV_CONST_HANDLER,
- ZEND_PRE_DEC_OBJ_SPEC_CV_TMP_HANDLER,
- ZEND_PRE_DEC_OBJ_SPEC_CV_VAR_HANDLER,
+ ZEND_PRE_DEC_OBJ_SPEC_CV_TMPVAR_HANDLER,
+ ZEND_PRE_DEC_OBJ_SPEC_CV_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_PRE_DEC_OBJ_SPEC_CV_CV_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_POST_INC_OBJ_SPEC_VAR_CONST_HANDLER,
- ZEND_POST_INC_OBJ_SPEC_VAR_TMP_HANDLER,
- ZEND_POST_INC_OBJ_SPEC_VAR_VAR_HANDLER,
+ ZEND_POST_INC_OBJ_SPEC_VAR_TMPVAR_HANDLER,
+ ZEND_POST_INC_OBJ_SPEC_VAR_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_POST_INC_OBJ_SPEC_VAR_CV_HANDLER,
ZEND_POST_INC_OBJ_SPEC_UNUSED_CONST_HANDLER,
- ZEND_POST_INC_OBJ_SPEC_UNUSED_TMP_HANDLER,
- ZEND_POST_INC_OBJ_SPEC_UNUSED_VAR_HANDLER,
+ ZEND_POST_INC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
+ ZEND_POST_INC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_POST_INC_OBJ_SPEC_UNUSED_CV_HANDLER,
ZEND_POST_INC_OBJ_SPEC_CV_CONST_HANDLER,
- ZEND_POST_INC_OBJ_SPEC_CV_TMP_HANDLER,
- ZEND_POST_INC_OBJ_SPEC_CV_VAR_HANDLER,
+ ZEND_POST_INC_OBJ_SPEC_CV_TMPVAR_HANDLER,
+ ZEND_POST_INC_OBJ_SPEC_CV_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_POST_INC_OBJ_SPEC_CV_CV_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_POST_DEC_OBJ_SPEC_VAR_CONST_HANDLER,
- ZEND_POST_DEC_OBJ_SPEC_VAR_TMP_HANDLER,
- ZEND_POST_DEC_OBJ_SPEC_VAR_VAR_HANDLER,
+ ZEND_POST_DEC_OBJ_SPEC_VAR_TMPVAR_HANDLER,
+ ZEND_POST_DEC_OBJ_SPEC_VAR_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_POST_DEC_OBJ_SPEC_VAR_CV_HANDLER,
ZEND_POST_DEC_OBJ_SPEC_UNUSED_CONST_HANDLER,
- ZEND_POST_DEC_OBJ_SPEC_UNUSED_TMP_HANDLER,
- ZEND_POST_DEC_OBJ_SPEC_UNUSED_VAR_HANDLER,
+ ZEND_POST_DEC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
+ ZEND_POST_DEC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_POST_DEC_OBJ_SPEC_UNUSED_CV_HANDLER,
ZEND_POST_DEC_OBJ_SPEC_CV_CONST_HANDLER,
- ZEND_POST_DEC_OBJ_SPEC_CV_TMP_HANDLER,
- ZEND_POST_DEC_OBJ_SPEC_CV_VAR_HANDLER,
+ ZEND_POST_DEC_OBJ_SPEC_CV_TMPVAR_HANDLER,
+ ZEND_POST_DEC_OBJ_SPEC_CV_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_POST_DEC_OBJ_SPEC_CV_CV_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_NULL_HANDLER,
ZEND_ASSIGN_OBJ_SPEC_VAR_CONST_HANDLER,
- ZEND_ASSIGN_OBJ_SPEC_VAR_TMP_HANDLER,
- ZEND_ASSIGN_OBJ_SPEC_VAR_VAR_HANDLER,
+ ZEND_ASSIGN_OBJ_SPEC_VAR_TMPVAR_HANDLER,
+ ZEND_ASSIGN_OBJ_SPEC_VAR_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_ASSIGN_OBJ_SPEC_VAR_CV_HANDLER,
ZEND_ASSIGN_OBJ_SPEC_UNUSED_CONST_HANDLER,
- ZEND_ASSIGN_OBJ_SPEC_UNUSED_TMP_HANDLER,
- ZEND_ASSIGN_OBJ_SPEC_UNUSED_VAR_HANDLER,
+ ZEND_ASSIGN_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
+ ZEND_ASSIGN_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_ASSIGN_OBJ_SPEC_UNUSED_CV_HANDLER,
ZEND_ASSIGN_OBJ_SPEC_CV_CONST_HANDLER,
- ZEND_ASSIGN_OBJ_SPEC_CV_TMP_HANDLER,
- ZEND_ASSIGN_OBJ_SPEC_CV_VAR_HANDLER,
+ ZEND_ASSIGN_OBJ_SPEC_CV_TMPVAR_HANDLER,
+ ZEND_ASSIGN_OBJ_SPEC_CV_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_ASSIGN_OBJ_SPEC_CV_CV_HANDLER,
ZEND_NULL_HANDLER,
ZEND_ASSIGN_DIM_SPEC_CV_UNUSED_HANDLER,
ZEND_ASSIGN_DIM_SPEC_CV_CV_HANDLER,
ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CONST_CONST_HANDLER,
- ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CONST_TMP_HANDLER,
- ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CONST_VAR_HANDLER,
+ ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CONST_TMPVAR_HANDLER,
+ ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CONST_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CONST_CV_HANDLER,
ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_TMP_CONST_HANDLER,
- ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_TMP_TMP_HANDLER,
- ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_TMP_VAR_HANDLER,
+ ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_TMP_TMPVAR_HANDLER,
+ ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_TMP_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_TMP_CV_HANDLER,
ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_CONST_HANDLER,
- ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_TMP_HANDLER,
- ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_VAR_HANDLER,
+ ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_TMPVAR_HANDLER,
+ ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_CV_HANDLER,
ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_CONST_HANDLER,
- ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_TMP_HANDLER,
- ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_VAR_HANDLER,
+ ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
+ ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_CV_HANDLER,
ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_CONST_HANDLER,
- ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_TMP_HANDLER,
- ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_VAR_HANDLER,
+ ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_TMPVAR_HANDLER,
+ ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_TMPVAR_HANDLER,
ZEND_NULL_HANDLER,
ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_CV_HANDLER,
ZEND_HANDLE_EXCEPTION_SPEC_HANDLER,