]> granicus.if.org Git - php/commitdiff
Get rid of duplicate handlers (where the code for IS_TMP_VAR and IS_VAR operands...
authorDmitry Stogov <dmitry@zend.com>
Fri, 5 Dec 2014 09:40:47 +0000 (12:40 +0300)
committerDmitry Stogov <dmitry@zend.com>
Fri, 5 Dec 2014 09:40:47 +0000 (12:40 +0300)
Zend/zend_vm_def.h
Zend/zend_vm_execute.h
Zend/zend_vm_gen.php

index 42b2acf69869105d4bd638f2ea8364d4711e9861..005d78584fa9eb1e7ebe49a8cdf52270bc5b40ae 100644 (file)
@@ -655,7 +655,7 @@ ZEND_VM_HANDLER(33, ZEND_ASSIGN_BW_XOR, VAR|UNUSED|CV, CONST|TMP|VAR|UNUSED|CV)
        }
 }
 
-ZEND_VM_HELPER_EX(zend_pre_incdec_property_helper, VAR|UNUSED|CV, CONST|TMP|VAR|CV, incdec_t incdec_op)
+ZEND_VM_HELPER_EX(zend_pre_incdec_property_helper, VAR|UNUSED|CV, CONST|TMPVAR|CV, incdec_t incdec_op)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
@@ -736,17 +736,17 @@ ZEND_VM_HELPER_EX(zend_pre_incdec_property_helper, VAR|UNUSED|CV, CONST|TMP|VAR|
        ZEND_VM_NEXT_OPCODE();
 }
 
-ZEND_VM_HANDLER(132, ZEND_PRE_INC_OBJ, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
+ZEND_VM_HANDLER(132, ZEND_PRE_INC_OBJ, VAR|UNUSED|CV, CONST|TMPVAR|CV)
 {
        ZEND_VM_DISPATCH_TO_HELPER_EX(zend_pre_incdec_property_helper, incdec_op, increment_function);
 }
 
-ZEND_VM_HANDLER(133, ZEND_PRE_DEC_OBJ, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
+ZEND_VM_HANDLER(133, ZEND_PRE_DEC_OBJ, VAR|UNUSED|CV, CONST|TMPVAR|CV)
 {
        ZEND_VM_DISPATCH_TO_HELPER_EX(zend_pre_incdec_property_helper, incdec_op, decrement_function);
 }
 
-ZEND_VM_HELPER_EX(zend_post_incdec_property_helper, VAR|UNUSED|CV, CONST|TMP|VAR|CV, incdec_t incdec_op)
+ZEND_VM_HELPER_EX(zend_post_incdec_property_helper, VAR|UNUSED|CV, CONST|TMPVAR|CV, incdec_t incdec_op)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
@@ -821,12 +821,12 @@ ZEND_VM_HELPER_EX(zend_post_incdec_property_helper, VAR|UNUSED|CV, CONST|TMP|VAR
        ZEND_VM_NEXT_OPCODE();
 }
 
-ZEND_VM_HANDLER(134, ZEND_POST_INC_OBJ, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
+ZEND_VM_HANDLER(134, ZEND_POST_INC_OBJ, VAR|UNUSED|CV, CONST|TMPVAR|CV)
 {
        ZEND_VM_DISPATCH_TO_HELPER_EX(zend_post_incdec_property_helper, incdec_op, increment_function);
 }
 
-ZEND_VM_HANDLER(135, ZEND_POST_DEC_OBJ, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
+ZEND_VM_HANDLER(135, ZEND_POST_DEC_OBJ, VAR|UNUSED|CV, CONST|TMPVAR|CV)
 {
        ZEND_VM_DISPATCH_TO_HELPER_EX(zend_post_incdec_property_helper, incdec_op, decrement_function);
 }
@@ -1013,7 +1013,7 @@ ZEND_VM_HANDLER(41, ZEND_PRINT, CONST|TMP|VAR|CV, ANY)
        ZEND_VM_DISPATCH_TO_HANDLER(ZEND_ECHO);
 }
 
-ZEND_VM_HELPER_EX(zend_fetch_var_address_helper, CONST|TMP|VAR|CV, UNUSED|CONST|VAR, int type)
+ZEND_VM_HELPER_EX(zend_fetch_var_address_helper, CONST|TMPVAR|CV, UNUSED|CONST|VAR, int type)
 {
        USE_OPLINE
        zend_free_op free_op1;
@@ -1125,22 +1125,22 @@ ZEND_VM_HELPER_EX(zend_fetch_var_address_helper, CONST|TMP|VAR|CV, UNUSED|CONST|
        ZEND_VM_NEXT_OPCODE();
 }
 
-ZEND_VM_HANDLER(80, ZEND_FETCH_R, CONST|TMP|VAR|CV, UNUSED|CONST|VAR)
+ZEND_VM_HANDLER(80, ZEND_FETCH_R, CONST|TMPVAR|CV, UNUSED|CONST|VAR)
 {
        ZEND_VM_DISPATCH_TO_HELPER_EX(zend_fetch_var_address_helper, type, BP_VAR_R);
 }
 
-ZEND_VM_HANDLER(83, ZEND_FETCH_W, CONST|TMP|VAR|CV, UNUSED|CONST|VAR)
+ZEND_VM_HANDLER(83, ZEND_FETCH_W, CONST|TMPVAR|CV, UNUSED|CONST|VAR)
 {
        ZEND_VM_DISPATCH_TO_HELPER_EX(zend_fetch_var_address_helper, type, BP_VAR_W);
 }
 
-ZEND_VM_HANDLER(86, ZEND_FETCH_RW, CONST|TMP|VAR|CV, UNUSED|CONST|VAR)
+ZEND_VM_HANDLER(86, ZEND_FETCH_RW, CONST|TMPVAR|CV, UNUSED|CONST|VAR)
 {
        ZEND_VM_DISPATCH_TO_HELPER_EX(zend_fetch_var_address_helper, type, BP_VAR_RW);
 }
 
-ZEND_VM_HANDLER(92, ZEND_FETCH_FUNC_ARG, CONST|TMP|VAR|CV, UNUSED|CONST|VAR)
+ZEND_VM_HANDLER(92, ZEND_FETCH_FUNC_ARG, CONST|TMPVAR|CV, UNUSED|CONST|VAR)
 {
        USE_OPLINE
 
@@ -1151,12 +1151,12 @@ ZEND_VM_HANDLER(92, ZEND_FETCH_FUNC_ARG, CONST|TMP|VAR|CV, UNUSED|CONST|VAR)
        }
 }
 
-ZEND_VM_HANDLER(95, ZEND_FETCH_UNSET, CONST|TMP|VAR|CV, UNUSED|CONST|VAR)
+ZEND_VM_HANDLER(95, ZEND_FETCH_UNSET, CONST|TMPVAR|CV, UNUSED|CONST|VAR)
 {
        ZEND_VM_DISPATCH_TO_HELPER_EX(zend_fetch_var_address_helper, type, BP_VAR_UNSET);
 }
 
-ZEND_VM_HANDLER(89, ZEND_FETCH_IS, CONST|TMP|VAR|CV, UNUSED|CONST|VAR)
+ZEND_VM_HANDLER(89, ZEND_FETCH_IS, CONST|TMPVAR|CV, UNUSED|CONST|VAR)
 {
        ZEND_VM_DISPATCH_TO_HELPER_EX(zend_fetch_var_address_helper, type, BP_VAR_IS);
 }
@@ -1296,7 +1296,7 @@ ZEND_VM_HANDLER(96, ZEND_FETCH_DIM_UNSET, VAR|CV, CONST|TMP|VAR|CV)
        ZEND_VM_NEXT_OPCODE();
 }
 
-ZEND_VM_HANDLER(82, ZEND_FETCH_OBJ_R, CONST|TMP|VAR|UNUSED|CV, CONST|TMP|VAR|CV)
+ZEND_VM_HANDLER(82, ZEND_FETCH_OBJ_R, CONST|TMP|VAR|UNUSED|CV, CONST|TMPVAR|CV)
 {
        USE_OPLINE
        zend_free_op free_op1;
@@ -1351,7 +1351,7 @@ ZEND_VM_HANDLER(82, ZEND_FETCH_OBJ_R, CONST|TMP|VAR|UNUSED|CV, CONST|TMP|VAR|CV)
        ZEND_VM_NEXT_OPCODE();
 }
 
-ZEND_VM_HANDLER(85, ZEND_FETCH_OBJ_W, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
+ZEND_VM_HANDLER(85, ZEND_FETCH_OBJ_W, VAR|UNUSED|CV, CONST|TMPVAR|CV)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
@@ -1376,7 +1376,7 @@ ZEND_VM_HANDLER(85, ZEND_FETCH_OBJ_W, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
        ZEND_VM_NEXT_OPCODE();
 }
 
-ZEND_VM_HANDLER(88, ZEND_FETCH_OBJ_RW, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
+ZEND_VM_HANDLER(88, ZEND_FETCH_OBJ_RW, VAR|UNUSED|CV, CONST|TMPVAR|CV)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
@@ -1400,7 +1400,7 @@ ZEND_VM_HANDLER(88, ZEND_FETCH_OBJ_RW, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
        ZEND_VM_NEXT_OPCODE();
 }
 
-ZEND_VM_HANDLER(91, ZEND_FETCH_OBJ_IS, CONST|TMP|VAR|UNUSED|CV, CONST|TMP|VAR|CV)
+ZEND_VM_HANDLER(91, ZEND_FETCH_OBJ_IS, CONST|TMP|VAR|UNUSED|CV, CONST|TMPVAR|CV)
 {
        USE_OPLINE
        zend_free_op free_op1;
@@ -1454,7 +1454,7 @@ ZEND_VM_HANDLER(91, ZEND_FETCH_OBJ_IS, CONST|TMP|VAR|UNUSED|CV, CONST|TMP|VAR|CV
        ZEND_VM_NEXT_OPCODE();
 }
 
-ZEND_VM_HANDLER(94, ZEND_FETCH_OBJ_FUNC_ARG, CONST|TMP|VAR|UNUSED|CV, CONST|TMP|VAR|CV)
+ZEND_VM_HANDLER(94, ZEND_FETCH_OBJ_FUNC_ARG, CONST|TMP|VAR|UNUSED|CV, CONST|TMPVAR|CV)
 {
        USE_OPLINE
        zval *container;
@@ -1487,7 +1487,7 @@ ZEND_VM_HANDLER(94, ZEND_FETCH_OBJ_FUNC_ARG, CONST|TMP|VAR|UNUSED|CV, CONST|TMP|
        }
 }
 
-ZEND_VM_HANDLER(97, ZEND_FETCH_OBJ_UNSET, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
+ZEND_VM_HANDLER(97, ZEND_FETCH_OBJ_UNSET, VAR|UNUSED|CV, CONST|TMPVAR|CV)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
@@ -1543,7 +1543,7 @@ ZEND_VM_HANDLER(98, ZEND_FETCH_LIST, CONST|TMP|VAR|CV, CONST)
        ZEND_VM_NEXT_OPCODE();
 }
 
-ZEND_VM_HANDLER(136, ZEND_ASSIGN_OBJ, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
+ZEND_VM_HANDLER(136, ZEND_ASSIGN_OBJ, VAR|UNUSED|CV, CONST|TMPVAR|CV)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
@@ -2042,7 +2042,7 @@ ZEND_VM_HANDLER(55, ZEND_ADD_STRING, TMP|UNUSED, CONST)
        ZEND_VM_NEXT_OPCODE();
 }
 
-ZEND_VM_HANDLER(56, ZEND_ADD_VAR, TMP|UNUSED, TMP|VAR|CV)
+ZEND_VM_HANDLER(56, ZEND_ADD_VAR, TMP|UNUSED, TMPVAR|CV)
 {
        USE_OPLINE
        zend_free_op free_op2;
@@ -2060,15 +2060,10 @@ ZEND_VM_HANDLER(56, ZEND_ADD_VAR, TMP|UNUSED, TMP|VAR|CV)
        }
 
        if (Z_TYPE_P(var) != IS_STRING) {
-               if (OP2_TYPE != IS_TMP_VAR) {
-                       ZVAL_DEREF(var);
-               }
-               if (Z_TYPE_P(var) != IS_STRING) {
-                       use_copy = zend_make_printable_zval(var, &var_copy TSRMLS_CC);
+               use_copy = zend_make_printable_zval(var, &var_copy TSRMLS_CC);
 
-                       if (use_copy) {
-                               var = &var_copy;
-                       }
+               if (use_copy) {
+                       var = &var_copy;
                }
        }
        add_string_to_string(str, str, var);
@@ -2128,7 +2123,7 @@ ZEND_VM_HANDLER(109, ZEND_FETCH_CLASS, ANY, CONST|TMP|VAR|UNUSED|CV)
        }
 }
 
-ZEND_VM_HANDLER(112, ZEND_INIT_METHOD_CALL, TMP|VAR|UNUSED|CV, CONST|TMP|VAR|CV)
+ZEND_VM_HANDLER(112, ZEND_INIT_METHOD_CALL, TMP|VAR|UNUSED|CV, CONST|TMPVAR|CV)
 {
        USE_OPLINE
        zval *function_name;
@@ -2237,7 +2232,7 @@ ZEND_VM_HANDLER(112, ZEND_INIT_METHOD_CALL, TMP|VAR|UNUSED|CV, CONST|TMP|VAR|CV)
        ZEND_VM_NEXT_OPCODE();
 }
 
-ZEND_VM_HANDLER(113, ZEND_INIT_STATIC_METHOD_CALL, CONST|VAR, CONST|TMP|VAR|UNUSED|CV)
+ZEND_VM_HANDLER(113, ZEND_INIT_STATIC_METHOD_CALL, CONST|VAR, CONST|TMPVAR|UNUSED|CV)
 {
        USE_OPLINE
        zval *function_name;
@@ -3030,7 +3025,7 @@ ZEND_VM_HANDLER(117, ZEND_SEND_VAR, VAR|CV, ANY)
        varptr = GET_OP1_ZVAL_PTR(BP_VAR_R);
        arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
        ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
-       if ((OP1_TYPE == IS_CV || OP1_TYPE == IS_VAR) && Z_ISREF_P(varptr)) {
+       if (Z_ISREF_P(varptr)) {
                ZVAL_COPY(arg, Z_REFVAL_P(varptr));
                FREE_OP1();
        } else {
@@ -3129,7 +3124,7 @@ ZEND_VM_HANDLER(66, ZEND_SEND_VAR_EX, VAR|CV, ANY)
        varptr = GET_OP1_ZVAL_PTR(BP_VAR_R);
        arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
        ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
-       if ((OP1_TYPE == IS_CV || OP1_TYPE == IS_VAR) && Z_ISREF_P(varptr)) {
+       if (Z_ISREF_P(varptr)) {
                ZVAL_COPY(arg, Z_REFVAL_P(varptr));
                FREE_OP1();
        } else {
@@ -3588,7 +3583,7 @@ ZEND_VM_HANDLER(164, ZEND_RECV_VARIADIC, ANY, ANY)
        ZEND_VM_NEXT_OPCODE();
 }
 
-ZEND_VM_HANDLER(52, ZEND_BOOL, CONST|TMP|VAR|CV, ANY)
+ZEND_VM_HANDLER(52, ZEND_BOOL, CONST|TMPVAR|CV, ANY)
 {
        USE_OPLINE
        zend_free_op free_op1;
@@ -3645,7 +3640,7 @@ ZEND_VM_HANDLER(100, ZEND_GOTO, ANY, CONST)
        ZEND_VM_JMP(opline->op1.jmp_addr);
 }
 
-ZEND_VM_HANDLER(48, ZEND_CASE, CONST|TMP|VAR|CV, CONST|TMP|VAR|CV)
+ZEND_VM_HANDLER(48, ZEND_CASE, CONST|TMPVAR|CV, CONST|TMPVAR|CV)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
@@ -3881,7 +3876,7 @@ ZEND_VM_C_LABEL(constant_fetch_end):
        ZEND_VM_NEXT_OPCODE();
 }
 
-ZEND_VM_HANDLER(72, ZEND_ADD_ARRAY_ELEMENT, CONST|TMP|VAR|CV, CONST|TMP|VAR|UNUSED|CV)
+ZEND_VM_HANDLER(72, ZEND_ADD_ARRAY_ELEMENT, CONST|TMP|VAR|CV, CONST|TMPVAR|UNUSED|CV)
 {
        USE_OPLINE
        zend_free_op free_op1;
@@ -3969,7 +3964,7 @@ ZEND_VM_C_LABEL(str_index):
        ZEND_VM_NEXT_OPCODE();
 }
 
-ZEND_VM_HANDLER(71, ZEND_INIT_ARRAY, CONST|TMP|VAR|UNUSED|CV, CONST|TMP|VAR|UNUSED|CV)
+ZEND_VM_HANDLER(71, ZEND_INIT_ARRAY, CONST|TMP|VAR|UNUSED|CV, CONST|TMPVAR|UNUSED|CV)
 {
        zval *array;
        uint32_t size;
@@ -4102,7 +4097,7 @@ ZEND_VM_HANDLER(21, ZEND_CAST, CONST|TMP|VAR|CV, ANY)
        ZEND_VM_NEXT_OPCODE();
 }
 
-ZEND_VM_HANDLER(73, ZEND_INCLUDE_OR_EVAL, CONST|TMP|VAR|CV, ANY)
+ZEND_VM_HANDLER(73, ZEND_INCLUDE_OR_EVAL, CONST|TMPVAR|CV, ANY)
 {
        USE_OPLINE
        zend_op_array *new_op_array=NULL;
@@ -4228,7 +4223,7 @@ ZEND_VM_HANDLER(73, ZEND_INCLUDE_OR_EVAL, CONST|TMP|VAR|CV, ANY)
        ZEND_VM_NEXT_OPCODE();
 }
 
-ZEND_VM_HANDLER(74, ZEND_UNSET_VAR, CONST|TMP|VAR|CV, UNUSED|CONST|VAR)
+ZEND_VM_HANDLER(74, ZEND_UNSET_VAR, CONST|TMPVAR|CV, UNUSED|CONST|VAR)
 {
        USE_OPLINE
        zval tmp, *varname;
@@ -4303,7 +4298,7 @@ ZEND_VM_HANDLER(74, ZEND_UNSET_VAR, CONST|TMP|VAR|CV, UNUSED|CONST|VAR)
        ZEND_VM_NEXT_OPCODE();
 }
 
-ZEND_VM_HANDLER(75, ZEND_UNSET_DIM, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
+ZEND_VM_HANDLER(75, ZEND_UNSET_DIM, VAR|UNUSED|CV, CONST|TMPVAR|CV)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
@@ -4388,7 +4383,7 @@ ZEND_VM_C_LABEL(num_index_dim):
        ZEND_VM_NEXT_OPCODE();
 }
 
-ZEND_VM_HANDLER(76, ZEND_UNSET_OBJ, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
+ZEND_VM_HANDLER(76, ZEND_UNSET_OBJ, VAR|UNUSED|CV, CONST|TMPVAR|CV)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
@@ -4857,7 +4852,7 @@ ZEND_VM_HANDLER(78, ZEND_FE_FETCH, VAR, ANY)
        }
 }
 
-ZEND_VM_HANDLER(114, ZEND_ISSET_ISEMPTY_VAR, CONST|TMP|VAR|CV, UNUSED|CONST|VAR)
+ZEND_VM_HANDLER(114, ZEND_ISSET_ISEMPTY_VAR, CONST|TMPVAR|CV, UNUSED|CONST|VAR)
 {
        USE_OPLINE
        zval *value;
@@ -4929,7 +4924,7 @@ ZEND_VM_HANDLER(114, ZEND_ISSET_ISEMPTY_VAR, CONST|TMP|VAR|CV, UNUSED|CONST|VAR)
        }
 }
 
-ZEND_VM_HANDLER(115, ZEND_ISSET_ISEMPTY_DIM_OBJ, CONST|TMP|VAR|UNUSED|CV, CONST|TMP|VAR|CV)
+ZEND_VM_HANDLER(115, ZEND_ISSET_ISEMPTY_DIM_OBJ, CONST|TMP|VAR|UNUSED|CV, CONST|TMPVAR|CV)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
@@ -5010,7 +5005,7 @@ ZEND_VM_C_LABEL(num_index_prop):
 
                result = 0;
                if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
-                       if (OP2_TYPE == IS_CV || OP2_TYPE == IS_VAR) {
+                       if (OP2_TYPE & (IS_CV|IS_VAR)) {
                                ZVAL_DEREF(offset);
                        }
                        if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
@@ -5043,7 +5038,7 @@ ZEND_VM_C_LABEL(num_index_prop):
        ZEND_VM_NEXT_OPCODE();
 }
 
-ZEND_VM_HANDLER(148, ZEND_ISSET_ISEMPTY_PROP_OBJ, CONST|TMP|VAR|UNUSED|CV, CONST|TMP|VAR|CV)
+ZEND_VM_HANDLER(148, ZEND_ISSET_ISEMPTY_PROP_OBJ, CONST|TMP|VAR|UNUSED|CV, CONST|TMPVAR|CV)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
@@ -5084,7 +5079,7 @@ ZEND_VM_HANDLER(79, ZEND_EXIT, CONST|TMP|VAR|UNUSED|CV, ANY)
        SAVE_OPLINE();
        if (OP1_TYPE != IS_UNUSED) {
                zend_free_op free_op1;
-               zval *ptr = GET_OP1_ZVAL_PTR(BP_VAR_R);
+               zval *ptr = GET_OP1_ZVAL_PTR_DEREF(BP_VAR_R);
 
                if (Z_TYPE_P(ptr) == IS_LONG) {
                        EG(exit_status) = Z_LVAL_P(ptr);
index 89c220aef1b6b9f62065c10a018f244656bdfbaf..4262329143866bca893eb7ea340fc69e1c309d69 100644 (file)
@@ -4769,7 +4769,7 @@ num_index_prop:
 
                result = 0;
                if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
-                       if (IS_CONST == IS_CV || IS_CONST == IS_VAR) {
+                       if (IS_CONST & (IS_CV|IS_VAR)) {
                                ZVAL_DEREF(offset);
                        }
                        if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
@@ -5229,808 +5229,260 @@ static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_CONST_TMP_HANDLER(ZEND_OP
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INIT_USER_CALL_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
-       zval *container;
        zend_free_op free_op2;
-       zval *offset;
-
-       SAVE_OPLINE();
-       container = opline->op1.zv;
-       offset  = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-
-       if ((IS_CONST != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
-           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
-               zend_error(E_NOTICE, "Trying to get property of non-object");
-               ZVAL_NULL(EX_VAR(opline->result.var));
-       } else {
-               zval *retval;
-
-               /* here we are sure we are dealing with an object */
-               do {
-                       if (IS_TMP_VAR == IS_CONST &&
-                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
-                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
-                               zend_object *zobj = Z_OBJ_P(container);
-
-                               if (EXPECTED(prop_info)) {
-                                       retval = OBJ_PROP(zobj, prop_info->offset);
-                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               } else if (EXPECTED(zobj->properties != NULL)) {
-                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
-                                       if (EXPECTED(retval)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               }
-                       }
-
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+       zval *function_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       zend_fcall_info_cache fcc;
+       char *error = NULL;
+       zend_function *func;
+       zend_class_entry *called_scope;
+       zend_object *object;
 
-                       if (retval != EX_VAR(opline->result.var)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+       if (zend_is_callable_ex(function_name, NULL, 0, NULL, &fcc, &error TSRMLS_CC)) {
+               if (error) {
+                       efree(error);
+               }
+               func = fcc.function_handler;
+               if (func->common.fn_flags & ZEND_ACC_CLOSURE) {
+                       /* Delay closure destruction until its invocation */
+                       func->common.prototype = (zend_function*)Z_OBJ_P(function_name);
+                       Z_ADDREF_P(function_name);
+               }
+               called_scope = fcc.called_scope;
+               object = fcc.object;
+               if (object) {
+                       GC_REFCOUNT(object)++; /* For $this pointer */
+               } else if (func->common.scope &&
+                          !(func->common.fn_flags & ZEND_ACC_STATIC)) {
+                       if (func->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
+                               zend_error(E_STRICT,
+                               "Non-static method %s::%s() should not be called statically",
+                               func->common.scope->name->val, func->common.function_name->val);
+                       } else {
+                               zend_error_noreturn(
+                                       E_ERROR,
+                                       "Non-static method %s::%s() cannot be called statically",
+                                       func->common.scope->name->val, func->common.function_name->val);
                        }
-               } while (0);
+               }
+       } else {
+               zend_error(E_WARNING, "%s() expects parameter 1 to be a valid callback, %s", Z_STRVAL_P(opline->op1.zv), error);
+               efree(error);
+               func = (zend_function*)&zend_pass_function;
+               called_scope = NULL;
+               object = NULL;
        }
 
-       zval_ptr_dtor_nogc(free_op2);
+       EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
+               func, opline->extended_value, called_scope, object, EX(call) TSRMLS_CC);
 
+       zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_YIELD_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *container;
-       zend_free_op free_op2;
-       zval *offset;
-
-       SAVE_OPLINE();
-       container = opline->op1.zv;
-       offset  = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-
-       if ((IS_CONST != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
-           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
-               ZVAL_NULL(EX_VAR(opline->result.var));
-       } else {
-               zval *retval;
+       /* The generator object is stored in EX(return_value) */
+       zend_generator *generator = (zend_generator *) EX(return_value);
 
-               /* here we are sure we are dealing with an object */
-               do {
-                       if (IS_TMP_VAR == IS_CONST &&
-                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
-                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
-                               zend_object *zobj = Z_OBJ_P(container);
+       if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
+               zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
+       }
 
-                               if (EXPECTED(prop_info)) {
-                                       retval = OBJ_PROP(zobj, prop_info->offset);
-                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               } else if (EXPECTED(zobj->properties != NULL)) {
-                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
-                                       if (EXPECTED(retval)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               }
-                       }
+       /* Destroy the previously yielded value */
+       zval_ptr_dtor(&generator->value);
 
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+       /* Destroy the previously yielded key */
+       zval_ptr_dtor(&generator->key);
 
-                       if (retval != EX_VAR(opline->result.var)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                       }
-               } while (0);
-       }
+       /* Set the new yielded value */
+       if (IS_CONST != IS_UNUSED) {
 
-       zval_ptr_dtor_nogc(free_op2);
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+               if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
+                       /* Constants and temporary variables aren't yieldable by reference,
+                        * but we still allow them with a notice. */
+                       if (IS_CONST == IS_CONST || IS_CONST == IS_TMP_VAR) {
+                               zval *value;
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *container;
+                               zend_error(E_NOTICE, "Only variable references should be yielded by reference");
 
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-               /* Behave like FETCH_OBJ_W */
-               zend_free_op free_op1, free_op2;
-               zval *property;
+                               value = opline->op1.zv;
+                               ZVAL_COPY_VALUE(&generator->value, value);
+                               if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
 
-               SAVE_OPLINE();
-               property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-               container = NULL;
+                               /* Temporary variables don't need ctor copying */
+                               if (IS_CONST != IS_TMP_VAR) {
+                                       zval_opt_copy_ctor(&generator->value);
+                               }
+                       } else {
+                               zval *value_ptr = NULL;
 
-        if (IS_CONST == IS_CONST || IS_CONST == IS_TMP_VAR) {
-            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
-        }
-               if (IS_CONST == IS_VAR && UNEXPECTED(container == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
-               }
-               zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CONST, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op2);
-               if (IS_CONST == IS_VAR && READY_TO_DESTROY(free_op1)) {
-                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-               }
+                               if (IS_CONST == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+                                       zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
+                               }
 
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       } else {
-               return ZEND_FETCH_OBJ_R_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
+                               /* If a function call result is yielded and the function did
+                                * not return by reference we throw a notice. */
+                               if (IS_CONST == IS_VAR &&
+                                   (value_ptr == &EG(uninitialized_zval) ||
+                                    (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+                                     !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+                                       zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+                               } else {
+                                       ZVAL_MAKE_REF(value_ptr);
+                               }
+                               ZVAL_COPY(&generator->value, value_ptr);
 
-static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *function_name;
-       zend_class_entry *ce;
-       zend_object *object;
-       zend_function *fbc;
+                       }
+               } else {
+                       zval *value = opline->op1.zv;
 
-       SAVE_OPLINE();
+                       /* Consts, temporary variables and references need copying */
+                       if (IS_CONST == IS_CONST) {
+                               ZVAL_DUP(&generator->value, value);
+                       } else if (IS_CONST == IS_TMP_VAR) {
+                               ZVAL_COPY_VALUE(&generator->value, value);
+            } else if ((IS_CONST == IS_CV || IS_CONST == IS_VAR) && Z_ISREF_P(value)) {
+                               ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
 
-       if (IS_CONST == IS_CONST) {
-               /* no function found. try a static method in class */
-               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv))) {
-                       ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv));
-               } else {
-                       ce = zend_fetch_class_by_name(Z_STR_P(opline->op1.zv), opline->op1.zv + 1, ZEND_FETCH_CLASS_DEFAULT TSRMLS_CC);
-                       if (UNEXPECTED(EG(exception) != NULL)) {
-                               HANDLE_EXCEPTION();
-                       }
-                       if (UNEXPECTED(ce == NULL)) {
-                               zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
+                       } else {
+                               ZVAL_COPY_VALUE(&generator->value, value);
+                               if (IS_CONST == IS_CV) {
+                                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+                               }
                        }
-                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op1.zv), ce);
                }
        } else {
-               ce = Z_CE_P(EX_VAR(opline->op1.var));
+               /* If no value was specified yield null */
+               ZVAL_NULL(&generator->value);
        }
 
-       if (IS_CONST == IS_CONST &&
-           IS_TMP_VAR == IS_CONST &&
-           CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-               fbc = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-       } else if (IS_CONST != IS_CONST &&
-                  IS_TMP_VAR == IS_CONST &&
-                  (fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce))) {
-               /* do nothing */
-       } else if (IS_TMP_VAR != IS_UNUSED) {
+       /* Set the new yielded key */
+       if (IS_TMP_VAR != IS_UNUSED) {
                zend_free_op free_op2;
+               zval *key = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
 
-               function_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-               if (IS_TMP_VAR != IS_CONST) {
-                       if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
-                               if (UNEXPECTED(EG(exception) != NULL)) {
-                                       HANDLE_EXCEPTION();
-                               }
-                               zend_error_noreturn(E_ERROR, "Function name must be a string");
-                       }
-               }
+               /* Consts, temporary variables and references need copying */
+               if (IS_TMP_VAR == IS_CONST) {
+                       ZVAL_DUP(&generator->key, key);
+               } else if (IS_TMP_VAR == IS_TMP_VAR) {
+                       ZVAL_COPY_VALUE(&generator->key, key);
+               } else if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && Z_ISREF_P(key)) {
+                       ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
 
-               if (ce->get_static_method) {
-                       fbc = ce->get_static_method(ce, Z_STR_P(function_name) TSRMLS_CC);
                } else {
-                       fbc = zend_std_get_static_method(ce, Z_STR_P(function_name), ((IS_TMP_VAR == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
-               }
-               if (UNEXPECTED(fbc == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name->val, Z_STRVAL_P(function_name));
-               }
-               if (IS_TMP_VAR == IS_CONST &&
-                   EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
-                   EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0)) {
-                       if (IS_CONST == IS_CONST) {
-                               CACHE_PTR(Z_CACHE_SLOT_P(function_name), fbc);
-                       } else {
-                               CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), ce, fbc);
+                       ZVAL_COPY_VALUE(&generator->key, key);
+                       if (IS_TMP_VAR == IS_CV) {
+                               if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
                        }
                }
-               if (IS_TMP_VAR != IS_CONST) {
-                       zval_ptr_dtor_nogc(free_op2);
-               }
-       } else {
-               if (UNEXPECTED(ce->constructor == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot call constructor");
-               }
-               if (Z_OBJ(EX(This)) && Z_OBJ(EX(This))->ce != ce->constructor->common.scope && (ce->constructor->common.fn_flags & ZEND_ACC_PRIVATE)) {
-                       zend_error_noreturn(E_ERROR, "Cannot call private %s::__construct()", ce->name->val);
-               }
-               fbc = ce->constructor;
-       }
 
-       object = NULL;
-       if (!(fbc->common.fn_flags & ZEND_ACC_STATIC)) {
-               if (Z_OBJ(EX(This))) {
-                       object = Z_OBJ(EX(This));
-                       GC_REFCOUNT(object)++;
-               }
-               if (!object ||
-                   !instanceof_function(object->ce, ce TSRMLS_CC)) {
-                   /* We are calling method of the other (incompatible) class,
-                      but passing $this. This is done for compatibility with php-4. */
-                       if (fbc->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
-                               zend_error(
-                                       object ? E_DEPRECATED : E_STRICT,
-                                       "Non-static method %s::%s() should not be called statically%s",
-                                       fbc->common.scope->name->val, fbc->common.function_name->val,
-                                       object ? ", assuming $this from incompatible context" : "");
-                       } else {
-                               /* An internal function assumes $this is present and won't check that. So PHP would crash by allowing the call. */
-                               zend_error_noreturn(
-                                       E_ERROR,
-                                       "Non-static method %s::%s() cannot be called statically%s",
-                                       fbc->common.scope->name->val, fbc->common.function_name->val,
-                                       object ? ", assuming $this from incompatible context" : "");
-                       }
+               if (Z_TYPE(generator->key) == IS_LONG
+                   && Z_LVAL(generator->key) > generator->largest_used_integer_key
+               ) {
+                       generator->largest_used_integer_key = Z_LVAL(generator->key);
                }
+       } else {
+               /* If no key was specified we use auto-increment keys */
+               generator->largest_used_integer_key++;
+               ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
        }
 
-       if (IS_CONST != IS_CONST) {
-               /* previous opcode is ZEND_FETCH_CLASS */
-               if ((opline-1)->extended_value == ZEND_FETCH_CLASS_PARENT || (opline-1)->extended_value == ZEND_FETCH_CLASS_SELF) {
-                       ce = EX(called_scope);
-               }
+       if (RETURN_VALUE_USED(opline)) {
+               /* If the return value of yield is used set the send
+                * target and initialize it to NULL */
+               generator->send_target = EX_VAR(opline->result.var);
+               ZVAL_NULL(generator->send_target);
+       } else {
+               generator->send_target = NULL;
        }
 
-       EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
-               fbc, opline->extended_value, ce, object, EX(call) TSRMLS_CC);
+       /* We increment to the next op, so we are at the correct position when the
+        * generator is resumed. */
+       ZEND_VM_INC_OPCODE();
 
-       if (IS_TMP_VAR == IS_UNUSED) {
-               EX(call)->return_value = NULL;
-       }
+       /* The GOTO VM uses a local opline variable. We need to set the opline
+        * variable in execute_data so we don't resume at an old position. */
+       SAVE_OPLINE();
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       ZEND_VM_RETURN();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_USER_CALL_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_POW_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op2;
-       zval *function_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-       zend_fcall_info_cache fcc;
-       char *error = NULL;
-       zend_function *func;
-       zend_class_entry *called_scope;
-       zend_object *object;
-
-       if (zend_is_callable_ex(function_name, NULL, 0, NULL, &fcc, &error TSRMLS_CC)) {
-               if (error) {
-                       efree(error);
-               }
-               func = fcc.function_handler;
-               if (func->common.fn_flags & ZEND_ACC_CLOSURE) {
-                       /* Delay closure destruction until its invocation */
-                       func->common.prototype = (zend_function*)Z_OBJ_P(function_name);
-                       Z_ADDREF_P(function_name);
-               }
-               called_scope = fcc.called_scope;
-               object = fcc.object;
-               if (object) {
-                       GC_REFCOUNT(object)++; /* For $this pointer */
-               } else if (func->common.scope &&
-                          !(func->common.fn_flags & ZEND_ACC_STATIC)) {
-                       if (func->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
-                               zend_error(E_STRICT,
-                               "Non-static method %s::%s() should not be called statically",
-                               func->common.scope->name->val, func->common.function_name->val);
-                       } else {
-                               zend_error_noreturn(
-                                       E_ERROR,
-                                       "Non-static method %s::%s() cannot be called statically",
-                                       func->common.scope->name->val, func->common.function_name->val);
-                       }
-               }
-       } else {
-               zend_error(E_WARNING, "%s() expects parameter 1 to be a valid callback, %s", Z_STRVAL_P(opline->op1.zv), error);
-               efree(error);
-               func = (zend_function*)&zend_pass_function;
-               called_scope = NULL;
-               object = NULL;
-       }
 
-       EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
-               func, opline->extended_value, called_scope, object, EX(call) TSRMLS_CC);
+       SAVE_OPLINE();
+       pow_function(EX_VAR(opline->result.var),
+               opline->op1.zv,
+               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
 
        zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_CASE_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_MOD_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op2;
-       zval *result = EX_VAR(opline->result.var);
 
        SAVE_OPLINE();
-       fast_equal_function(result,
-                opline->op1.zv,
-                _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       fast_mod_function(EX_VAR(opline->result.var),
+               opline->op1.zv,
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
 
        zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SL_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
-       zval *expr_ptr, new_expr;
+       zend_free_op free_op2;
 
        SAVE_OPLINE();
-       if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) &&
-           (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
-               expr_ptr = NULL;
-               if (IS_CONST == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
-               }
-               ZVAL_MAKE_REF(expr_ptr);
-               Z_ADDREF_P(expr_ptr);
-
-       } else {
-               expr_ptr = opline->op1.zv;
-               if (IS_CONST == IS_TMP_VAR) {
-                       ZVAL_COPY_VALUE(&new_expr, expr_ptr);
-                       expr_ptr = &new_expr;
-               } else if (IS_CONST == IS_CONST) {
-                       if (!Z_IMMUTABLE_P(expr_ptr)) {
-                               ZVAL_DUP(&new_expr, expr_ptr);
-                               expr_ptr = &new_expr;
-                       }
-               } else if ((IS_CONST == IS_CV || IS_CONST == IS_VAR) && Z_ISREF_P(expr_ptr)) {
-                       expr_ptr = Z_REFVAL_P(expr_ptr);
-                       if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
-
-               } else if (IS_CONST == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
-                       Z_ADDREF_P(expr_ptr);
-               }
-       }
-
-       if (IS_TMP_VAR != IS_UNUSED) {
-               zend_free_op free_op2;
-               zval *offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-               zend_string *str;
-               zend_ulong hval;
+       shift_left_function(EX_VAR(opline->result.var),
+               opline->op1.zv,
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
 
-add_again:
-               switch (Z_TYPE_P(offset)) {
-                       case IS_DOUBLE:
-                               hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                               goto num_index;
-                       case IS_LONG:
-                               hval = Z_LVAL_P(offset);
-num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
-                               break;
-                       case IS_STRING:
-                               str = Z_STR_P(offset);
-                               if (IS_TMP_VAR != IS_CONST) {
-                                       if (ZEND_HANDLE_NUMERIC(str, hval)) {
-                                               goto num_index;
-                                       }
-                               }
-str_index:
-                               zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
-                               break;
-                       case IS_NULL:
-                               str = STR_EMPTY_ALLOC();
-                               goto str_index;
-                       case IS_FALSE:
-                               hval = 0;
-                               goto num_index;
-                       case IS_TRUE:
-                               hval = 1;
-                               goto num_index;
-                       case IS_REFERENCE:
-                               offset = Z_REFVAL_P(offset);
-                               goto add_again;
-                               break;
-                       default:
-                               zend_error(E_WARNING, "Illegal offset type");
-                               zval_ptr_dtor(expr_ptr);
-                               /* do nothing */
-                               break;
-               }
-               zval_ptr_dtor_nogc(free_op2);
-       } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
-       }
+       zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SR_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zval *array;
-       uint32_t size;
        USE_OPLINE
+       zend_free_op free_op2;
 
-       array = EX_VAR(opline->result.var);
-       if (IS_CONST != IS_UNUSED) {
-               size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
-       } else {
-               size = 0;
-       }
-       ZVAL_NEW_ARR(array);
-       zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
-
-       if (IS_CONST != IS_UNUSED) {
-               /* Explicitly initialize array as not-packed if flag is set */
-               if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
-                       zend_hash_real_init(Z_ARRVAL_P(array), 0);
-               }
-       }
+       SAVE_OPLINE();
+       shift_right_function(EX_VAR(opline->result.var),
+               opline->op1.zv,
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
 
-       if (IS_CONST == IS_UNUSED) {
-               ZEND_VM_NEXT_OPCODE();
-#if 0 || IS_CONST != IS_UNUSED
-       } else {
-               return ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-#endif
-       }
+       zval_ptr_dtor_nogc(free_op2);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op2;
-       zval *container;
-       int result;
-       zend_ulong hval;
-       zval *offset;
 
        SAVE_OPLINE();
-       container = opline->op1.zv;
-       offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-
-       if (IS_CONST != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
-               HashTable *ht = Z_ARRVAL_P(container);
-               zval *value;
-               zend_string *str;
-
-isset_again:
-               if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
-                       str = Z_STR_P(offset);
-                       if (IS_TMP_VAR != IS_CONST) {
-                               if (ZEND_HANDLE_NUMERIC(str, hval)) {
-                                       goto num_index_prop;
-                               }
-                       }
-str_index_prop:
-                       value = zend_hash_find_ind(ht, str);
-               } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
-                       hval = Z_LVAL_P(offset);
-num_index_prop:
-                       value = zend_hash_index_find(ht, hval);
-               } else {
-                       switch (Z_TYPE_P(offset)) {
-                               case IS_DOUBLE:
-                                       hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                                       goto num_index_prop;
-                               case IS_NULL:
-                                       str = STR_EMPTY_ALLOC();
-                                       goto str_index_prop;
-                               case IS_FALSE:
-                                       hval = 0;
-                                       goto num_index_prop;
-                               case IS_TRUE:
-                                       hval = 1;
-                                       goto num_index_prop;
-                               case IS_RESOURCE:
-                                       hval = Z_RES_HANDLE_P(offset);
-                                       goto num_index_prop;
-                               case IS_REFERENCE:
-                                       offset = Z_REFVAL_P(offset);
-                                       goto isset_again;
-                               default:
-                                       zend_error(E_WARNING, "Illegal offset type in isset or empty");
-                                       value = NULL;
-                                       break;
-                       }
-               }
-
-               if (opline->extended_value & ZEND_ISSET) {
-                       /* > IS_NULL means not IS_UNDEF and not IS_NULL */
-                       result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
-               }
-       } else if (IS_CONST == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
-                       result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
-               } else {
-                       zend_error(E_NOTICE, "Trying to check element of non-array");
-                       result = 0;
-               }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
-               }
-       } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
-               zval tmp;
-
-               result = 0;
-               if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
-                       if (IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) {
-                               ZVAL_DEREF(offset);
-                       }
-                       if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
-                                       || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
-                                               && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
-                               ZVAL_DUP(&tmp, offset);
-                               convert_to_long(&tmp);
-                               offset = &tmp;
-                       }
-               }
-               if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
-                       if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
-                               if ((opline->extended_value & ZEND_ISSET) ||
-                                   Z_STRVAL_P(container)[offset->value.lval] != '0') {
-                                       result = 1;
-                               }
-                       }
-               }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
-               }
-       } else {
-               result = ((opline->extended_value & ZEND_ISSET) == 0);
-       }
-
-       zval_ptr_dtor_nogc(free_op2);
-       ZVAL_BOOL(EX_VAR(opline->result.var), result);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
-       zval *container;
-       int result;
-       zval *offset;
-
-       SAVE_OPLINE();
-       container = opline->op1.zv;
-       offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-
-       if (IS_CONST == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
-                       result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
-               } else {
-                       zend_error(E_NOTICE, "Trying to check property of non-object");
-                       result = 0;
-               }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
-               }
-       } else {
-               result = ((opline->extended_value & ZEND_ISSET) == 0);
-       }
-
-       zval_ptr_dtor_nogc(free_op2);
-       ZVAL_BOOL(EX_VAR(opline->result.var), result);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_YIELD_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       /* The generator object is stored in EX(return_value) */
-       zend_generator *generator = (zend_generator *) EX(return_value);
-
-       if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
-               zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
-       }
-
-       /* Destroy the previously yielded value */
-       zval_ptr_dtor(&generator->value);
-
-       /* Destroy the previously yielded key */
-       zval_ptr_dtor(&generator->key);
-
-       /* Set the new yielded value */
-       if (IS_CONST != IS_UNUSED) {
-
-
-               if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
-                       /* Constants and temporary variables aren't yieldable by reference,
-                        * but we still allow them with a notice. */
-                       if (IS_CONST == IS_CONST || IS_CONST == IS_TMP_VAR) {
-                               zval *value;
-
-                               zend_error(E_NOTICE, "Only variable references should be yielded by reference");
-
-                               value = opline->op1.zv;
-                               ZVAL_COPY_VALUE(&generator->value, value);
-                               if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
-
-                               /* Temporary variables don't need ctor copying */
-                               if (IS_CONST != IS_TMP_VAR) {
-                                       zval_opt_copy_ctor(&generator->value);
-                               }
-                       } else {
-                               zval *value_ptr = NULL;
-
-                               if (IS_CONST == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
-                                       zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
-                               }
-
-                               /* If a function call result is yielded and the function did
-                                * not return by reference we throw a notice. */
-                               if (IS_CONST == IS_VAR &&
-                                   (value_ptr == &EG(uninitialized_zval) ||
-                                    (opline->extended_value == ZEND_RETURNS_FUNCTION &&
-                                     !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
-                                       zend_error(E_NOTICE, "Only variable references should be yielded by reference");
-                               } else {
-                                       ZVAL_MAKE_REF(value_ptr);
-                               }
-                               ZVAL_COPY(&generator->value, value_ptr);
-
-                       }
-               } else {
-                       zval *value = opline->op1.zv;
-
-                       /* Consts, temporary variables and references need copying */
-                       if (IS_CONST == IS_CONST) {
-                               ZVAL_DUP(&generator->value, value);
-                       } else if (IS_CONST == IS_TMP_VAR) {
-                               ZVAL_COPY_VALUE(&generator->value, value);
-            } else if ((IS_CONST == IS_CV || IS_CONST == IS_VAR) && Z_ISREF_P(value)) {
-                               ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
-
-                       } else {
-                               ZVAL_COPY_VALUE(&generator->value, value);
-                               if (IS_CONST == IS_CV) {
-                                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
-                               }
-                       }
-               }
-       } else {
-               /* If no value was specified yield null */
-               ZVAL_NULL(&generator->value);
-       }
-
-       /* Set the new yielded key */
-       if (IS_TMP_VAR != IS_UNUSED) {
-               zend_free_op free_op2;
-               zval *key = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-
-               /* Consts, temporary variables and references need copying */
-               if (IS_TMP_VAR == IS_CONST) {
-                       ZVAL_DUP(&generator->key, key);
-               } else if (IS_TMP_VAR == IS_TMP_VAR) {
-                       ZVAL_COPY_VALUE(&generator->key, key);
-               } else if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && Z_ISREF_P(key)) {
-                       ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
-
-               } else {
-                       ZVAL_COPY_VALUE(&generator->key, key);
-                       if (IS_TMP_VAR == IS_CV) {
-                               if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
-                       }
-               }
-
-               if (Z_TYPE(generator->key) == IS_LONG
-                   && Z_LVAL(generator->key) > generator->largest_used_integer_key
-               ) {
-                       generator->largest_used_integer_key = Z_LVAL(generator->key);
-               }
-       } else {
-               /* If no key was specified we use auto-increment keys */
-               generator->largest_used_integer_key++;
-               ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
-       }
-
-       if (RETURN_VALUE_USED(opline)) {
-               /* If the return value of yield is used set the send
-                * target and initialize it to NULL */
-               generator->send_target = EX_VAR(opline->result.var);
-               ZVAL_NULL(generator->send_target);
-       } else {
-               generator->send_target = NULL;
-       }
-
-       /* We increment to the next op, so we are at the correct position when the
-        * generator is resumed. */
-       ZEND_VM_INC_OPCODE();
-
-       /* The GOTO VM uses a local opline variable. We need to set the opline
-        * variable in execute_data so we don't resume at an old position. */
-       SAVE_OPLINE();
-
-       ZEND_VM_RETURN();
-}
-
-static int ZEND_FASTCALL  ZEND_POW_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
-
-       SAVE_OPLINE();
-       pow_function(EX_VAR(opline->result.var),
-               opline->op1.zv,
-               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
-
-       zval_ptr_dtor_nogc(free_op2);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_MOD_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
-
-       SAVE_OPLINE();
-       fast_mod_function(EX_VAR(opline->result.var),
-               opline->op1.zv,
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
-
-       zval_ptr_dtor_nogc(free_op2);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_SL_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
-
-       SAVE_OPLINE();
-       shift_left_function(EX_VAR(opline->result.var),
-               opline->op1.zv,
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
-
-       zval_ptr_dtor_nogc(free_op2);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_SR_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
-
-       SAVE_OPLINE();
-       shift_right_function(EX_VAR(opline->result.var),
-               opline->op1.zv,
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
-
-       zval_ptr_dtor_nogc(free_op2);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
-
-       SAVE_OPLINE();
-       concat_function(EX_VAR(opline->result.var),
-               opline->op1.zv,
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       concat_function(EX_VAR(opline->result.var),
+               opline->op1.zv,
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
 
        zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
@@ -6342,149 +5794,537 @@ static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_CONST_VAR_HANDLER(ZEND_OP
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INIT_USER_CALL_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
-       zval *container;
        zend_free_op free_op2;
-       zval *offset;
-
-       SAVE_OPLINE();
-       container = opline->op1.zv;
-       offset  = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
-       if ((IS_CONST != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
-           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
-               zend_error(E_NOTICE, "Trying to get property of non-object");
-               ZVAL_NULL(EX_VAR(opline->result.var));
-       } else {
-               zval *retval;
-
-               /* here we are sure we are dealing with an object */
-               do {
-                       if (IS_VAR == IS_CONST &&
-                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
-                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
-                               zend_object *zobj = Z_OBJ_P(container);
-
-                               if (EXPECTED(prop_info)) {
-                                       retval = OBJ_PROP(zobj, prop_info->offset);
-                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               } else if (EXPECTED(zobj->properties != NULL)) {
-                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
-                                       if (EXPECTED(retval)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               }
-                       }
-
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+       zval *function_name = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+       zend_fcall_info_cache fcc;
+       char *error = NULL;
+       zend_function *func;
+       zend_class_entry *called_scope;
+       zend_object *object;
 
-                       if (retval != EX_VAR(opline->result.var)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+       if (zend_is_callable_ex(function_name, NULL, 0, NULL, &fcc, &error TSRMLS_CC)) {
+               if (error) {
+                       efree(error);
+               }
+               func = fcc.function_handler;
+               if (func->common.fn_flags & ZEND_ACC_CLOSURE) {
+                       /* Delay closure destruction until its invocation */
+                       func->common.prototype = (zend_function*)Z_OBJ_P(function_name);
+                       Z_ADDREF_P(function_name);
+               }
+               called_scope = fcc.called_scope;
+               object = fcc.object;
+               if (object) {
+                       GC_REFCOUNT(object)++; /* For $this pointer */
+               } else if (func->common.scope &&
+                          !(func->common.fn_flags & ZEND_ACC_STATIC)) {
+                       if (func->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
+                               zend_error(E_STRICT,
+                               "Non-static method %s::%s() should not be called statically",
+                               func->common.scope->name->val, func->common.function_name->val);
+                       } else {
+                               zend_error_noreturn(
+                                       E_ERROR,
+                                       "Non-static method %s::%s() cannot be called statically",
+                                       func->common.scope->name->val, func->common.function_name->val);
                        }
-               } while (0);
+               }
+       } else {
+               zend_error(E_WARNING, "%s() expects parameter 1 to be a valid callback, %s", Z_STRVAL_P(opline->op1.zv), error);
+               efree(error);
+               func = (zend_function*)&zend_pass_function;
+               called_scope = NULL;
+               object = NULL;
        }
 
-       zval_ptr_dtor_nogc(free_op2);
+       EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
+               func, opline->extended_value, called_scope, object, EX(call) TSRMLS_CC);
 
+       zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zval tmp, *varname;
+       HashTable *target_symbol_table;
 
-       zval *container;
-       zend_free_op free_op2;
-       zval *offset;
 
        SAVE_OPLINE();
-       container = opline->op1.zv;
-       offset  = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
-       if ((IS_CONST != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
-           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
-               ZVAL_NULL(EX_VAR(opline->result.var));
-       } else {
-               zval *retval;
+       if (IS_CONST == IS_CV &&
+           IS_VAR == IS_UNUSED &&
+           (opline->extended_value & ZEND_QUICK_SET)) {
+               zval *var = EX_VAR(opline->op1.var);
 
-               /* here we are sure we are dealing with an object */
-               do {
-                       if (IS_VAR == IS_CONST &&
-                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
-                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
-                               zend_object *zobj = Z_OBJ_P(container);
+               if (Z_REFCOUNTED_P(var)) {
+                       zend_refcounted *garbage = Z_COUNTED_P(var);
 
-                               if (EXPECTED(prop_info)) {
-                                       retval = OBJ_PROP(zobj, prop_info->offset);
-                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               } else if (EXPECTED(zobj->properties != NULL)) {
-                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
-                                       if (EXPECTED(retval)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               }
+                       if (!--GC_REFCOUNT(garbage)) {
+                               ZVAL_UNDEF(var);
+                               _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
+                       } else {
+                               GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
+                               ZVAL_UNDEF(var);
                        }
+               } else {
+                       ZVAL_UNDEF(var);
+               }
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
+       }
 
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+       varname = opline->op1.zv;
 
-                       if (retval != EX_VAR(opline->result.var)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+       ZVAL_UNDEF(&tmp);
+       if (IS_CONST != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
+               ZVAL_STR(&tmp, zval_get_string(varname));
+               varname = &tmp;
+       }
+
+       if (IS_VAR != IS_UNUSED) {
+               zend_class_entry *ce;
+
+               if (IS_VAR == IS_CONST) {
+                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+                       } else {
+                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+                               if (UNEXPECTED(EG(exception) != NULL)) {
+                                       if (IS_CONST != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+                                               zend_string_release(Z_STR(tmp));
+                                       }
+
+                                       HANDLE_EXCEPTION();
+                               }
+                               if (UNEXPECTED(ce == NULL)) {
+                                       zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
+                               }
+                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
                        }
-               } while (0);
+               } else {
+                       ce = Z_CE_P(EX_VAR(opline->op2.var));
+               }
+               zend_std_unset_static_property(ce, Z_STR_P(varname), ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+       } else {
+               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+               zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
        }
 
-       zval_ptr_dtor_nogc(free_op2);
+       if (IS_CONST != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+               zend_string_release(Z_STR(tmp));
+       }
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *container;
-
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-               /* Behave like FETCH_OBJ_W */
-               zend_free_op free_op1, free_op2;
-               zval *property;
-
-               SAVE_OPLINE();
-               property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-               container = NULL;
+       zval *value;
 
+       SAVE_OPLINE();
+       if (IS_CONST == IS_CV &&
+           IS_VAR == IS_UNUSED &&
+           (opline->extended_value & ZEND_QUICK_SET)) {
+               value = EX_VAR(opline->op1.var);
+               if (opline->extended_value & ZEND_ISSET) {
+                       ZVAL_BOOL(EX_VAR(opline->result.var),
+                               Z_TYPE_P(value) > IS_NULL &&
+                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+                       ZVAL_BOOL(EX_VAR(opline->result.var),
+                               !i_zend_is_true(value TSRMLS_CC));
+                       CHECK_EXCEPTION();
+               }
+               ZEND_VM_NEXT_OPCODE();
+       } else {
+
+               zval tmp, *varname = opline->op1.zv;
+
+               ZVAL_UNDEF(&tmp);
+               if (IS_CONST != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
+                       ZVAL_STR(&tmp, zval_get_string(varname));
+                       varname = &tmp;
+               }
+
+               if (IS_VAR != IS_UNUSED) {
+                       zend_class_entry *ce;
+
+                       if (IS_VAR == IS_CONST) {
+                               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                                       ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+                               } else {
+                                       ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+                                       if (UNEXPECTED(ce == NULL)) {
+                                               CHECK_EXCEPTION();
+                                               ZEND_VM_NEXT_OPCODE();
+                                       }
+                                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+                               }
+                       } else {
+                               ce = Z_CE_P(EX_VAR(opline->op2.var));
+                       }
+                       value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+               } else {
+                       HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+                       value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
+               }
+
+               if (IS_CONST != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+                       zend_string_release(Z_STR(tmp));
+               }
+
+               if (opline->extended_value & ZEND_ISSET) {
+                       ZVAL_BOOL(EX_VAR(opline->result.var),
+                               value && Z_TYPE_P(value) > IS_NULL &&
+                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+                       ZVAL_BOOL(EX_VAR(opline->result.var),
+                               !value || !i_zend_is_true(value TSRMLS_CC));
+               }
+
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
+       }
+}
+
+static int ZEND_FASTCALL  ZEND_YIELD_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       /* The generator object is stored in EX(return_value) */
+       zend_generator *generator = (zend_generator *) EX(return_value);
+
+       if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
+               zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
+       }
+
+       /* Destroy the previously yielded value */
+       zval_ptr_dtor(&generator->value);
+
+       /* Destroy the previously yielded key */
+       zval_ptr_dtor(&generator->key);
+
+       /* Set the new yielded value */
+       if (IS_CONST != IS_UNUSED) {
+
+
+               if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
+                       /* Constants and temporary variables aren't yieldable by reference,
+                        * but we still allow them with a notice. */
+                       if (IS_CONST == IS_CONST || IS_CONST == IS_TMP_VAR) {
+                               zval *value;
+
+                               zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+
+                               value = opline->op1.zv;
+                               ZVAL_COPY_VALUE(&generator->value, value);
+                               if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
+
+                               /* Temporary variables don't need ctor copying */
+                               if (IS_CONST != IS_TMP_VAR) {
+                                       zval_opt_copy_ctor(&generator->value);
+                               }
+                       } else {
+                               zval *value_ptr = NULL;
+
+                               if (IS_CONST == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+                                       zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
+                               }
+
+                               /* If a function call result is yielded and the function did
+                                * not return by reference we throw a notice. */
+                               if (IS_CONST == IS_VAR &&
+                                   (value_ptr == &EG(uninitialized_zval) ||
+                                    (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+                                     !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+                                       zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+                               } else {
+                                       ZVAL_MAKE_REF(value_ptr);
+                               }
+                               ZVAL_COPY(&generator->value, value_ptr);
+
+                       }
+               } else {
+                       zval *value = opline->op1.zv;
+
+                       /* Consts, temporary variables and references need copying */
+                       if (IS_CONST == IS_CONST) {
+                               ZVAL_DUP(&generator->value, value);
+                       } else if (IS_CONST == IS_TMP_VAR) {
+                               ZVAL_COPY_VALUE(&generator->value, value);
+            } else if ((IS_CONST == IS_CV || IS_CONST == IS_VAR) && Z_ISREF_P(value)) {
+                               ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
+
+                       } else {
+                               ZVAL_COPY_VALUE(&generator->value, value);
+                               if (IS_CONST == IS_CV) {
+                                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+                               }
+                       }
+               }
+       } else {
+               /* If no value was specified yield null */
+               ZVAL_NULL(&generator->value);
+       }
+
+       /* Set the new yielded key */
+       if (IS_VAR != IS_UNUSED) {
+               zend_free_op free_op2;
+               zval *key = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+
+               /* Consts, temporary variables and references need copying */
+               if (IS_VAR == IS_CONST) {
+                       ZVAL_DUP(&generator->key, key);
+               } else if (IS_VAR == IS_TMP_VAR) {
+                       ZVAL_COPY_VALUE(&generator->key, key);
+               } else if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && Z_ISREF_P(key)) {
+                       ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
+                       zval_ptr_dtor_nogc(free_op2);
+               } else {
+                       ZVAL_COPY_VALUE(&generator->key, key);
+                       if (IS_VAR == IS_CV) {
+                               if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
+                       }
+               }
+
+               if (Z_TYPE(generator->key) == IS_LONG
+                   && Z_LVAL(generator->key) > generator->largest_used_integer_key
+               ) {
+                       generator->largest_used_integer_key = Z_LVAL(generator->key);
+               }
+       } else {
+               /* If no key was specified we use auto-increment keys */
+               generator->largest_used_integer_key++;
+               ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
+       }
+
+       if (RETURN_VALUE_USED(opline)) {
+               /* If the return value of yield is used set the send
+                * target and initialize it to NULL */
+               generator->send_target = EX_VAR(opline->result.var);
+               ZVAL_NULL(generator->send_target);
+       } else {
+               generator->send_target = NULL;
+       }
+
+       /* We increment to the next op, so we are at the correct position when the
+        * generator is resumed. */
+       ZEND_VM_INC_OPCODE();
+
+       /* The GOTO VM uses a local opline variable. We need to set the opline
+        * variable in execute_data so we don't resume at an old position. */
+       SAVE_OPLINE();
+
+       ZEND_VM_RETURN();
+}
+
+static int ZEND_FASTCALL  ZEND_POW_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op2;
+
+       SAVE_OPLINE();
+       pow_function(EX_VAR(opline->result.var),
+               opline->op1.zv,
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+
+       zval_ptr_dtor_nogc(free_op2);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CONST_UNUSED(int type, ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       zval *varname;
+       zval *retval;
+       zend_string *name;
+       HashTable *target_symbol_table;
+
+       SAVE_OPLINE();
+       varname = opline->op1.zv;
+
+       if (IS_CONST == IS_CONST) {
+               name = Z_STR_P(varname);
+       } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
+               name = Z_STR_P(varname);
+               zend_string_addref(name);
+       } else {
+               name = zval_get_string(varname);
+       }
+
+       if (IS_UNUSED != IS_UNUSED) {
+               zend_class_entry *ce;
+
+               if (IS_UNUSED == IS_CONST) {
+                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+                       } else {
+                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+                               if (UNEXPECTED(ce == NULL)) {
+                                       if (IS_CONST != IS_CONST) {
+                                               zend_string_release(name);
+                                       }
+
+                                       CHECK_EXCEPTION();
+                                       ZEND_VM_NEXT_OPCODE();
+                               }
+                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+                       }
+               } else {
+                       ce = Z_CE_P(EX_VAR(opline->op2.var));
+               }
+               retval = zend_std_get_static_property(ce, name, 0, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+
+       } else {
+               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+               retval = zend_hash_find(target_symbol_table, name);
+               if (retval == NULL) {
+                       switch (type) {
+                               case BP_VAR_R:
+                               case BP_VAR_UNSET:
+                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                       /* break missing intentionally */
+                               case BP_VAR_IS:
+                                       retval = &EG(uninitialized_zval);
+                                       break;
+                               case BP_VAR_RW:
+                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                       /* break missing intentionally */
+                               case BP_VAR_W:
+                                       retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
+                                       break;
+                               EMPTY_SWITCH_DEFAULT_CASE()
+                       }
+               /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
+               } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
+                       retval = Z_INDIRECT_P(retval);
+                       if (Z_TYPE_P(retval) == IS_UNDEF) {
+                               switch (type) {
+                                       case BP_VAR_R:
+                                       case BP_VAR_UNSET:
+                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                               /* break missing intentionally */
+                                       case BP_VAR_IS:
+                                               retval = &EG(uninitialized_zval);
+                                               break;
+                                       case BP_VAR_RW:
+                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                               /* break missing intentionally */
+                                       case BP_VAR_W:
+                                               ZVAL_NULL(retval);
+                                               break;
+                                       EMPTY_SWITCH_DEFAULT_CASE()
+                               }
+                       }
+               }
+               if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
+                       if (Z_CONSTANT_P(retval)) {
+                               zval_update_constant(retval, 1 TSRMLS_CC);
+                       }
+               } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
+
+               }
+       }
+
+       if (IS_CONST != IS_CONST) {
+               zend_string_release(name);
+       }
+
+       ZEND_ASSERT(retval != NULL);
+       if (type == BP_VAR_R || type == BP_VAR_IS) {
+               if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
+                       ZVAL_UNREF(retval);
+               }
+               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+       } else {
+               ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
+       }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_FETCH_R_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL  ZEND_FETCH_W_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL  ZEND_FETCH_RW_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL  ZEND_FETCH_FUNC_ARG_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+               return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else {
+               return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
+
+static int ZEND_FASTCALL  ZEND_FETCH_UNSET_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL  ZEND_FETCH_IS_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zval *container;
+       zend_free_op free_op1;
+
+       SAVE_OPLINE();
+
+       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
         if (IS_CONST == IS_CONST || IS_CONST == IS_TMP_VAR) {
             zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
         }
+               container = NULL;
                if (IS_CONST == IS_VAR && UNEXPECTED(container == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CONST, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op2);
+               ZVAL_DEREF(container);
+               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
                if (IS_CONST == IS_VAR && READY_TO_DESTROY(free_op1)) {
                        EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
                }
 
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
+
        } else {
-               return ZEND_FETCH_OBJ_R_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               if (IS_UNUSED == IS_UNUSED) {
+                       zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
+               }
+               container = opline->op1.zv;
+               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
+
+
        }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zval *function_name;
@@ -6513,18 +6353,18 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_VAR_HANDLER(ZE
        }
 
        if (IS_CONST == IS_CONST &&
-           IS_VAR == IS_CONST &&
+           IS_UNUSED == IS_CONST &&
            CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
                fbc = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
        } else if (IS_CONST != IS_CONST &&
-                  IS_VAR == IS_CONST &&
+                  IS_UNUSED == IS_CONST &&
                   (fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce))) {
                /* do nothing */
-       } else if (IS_VAR != IS_UNUSED) {
-               zend_free_op free_op2;
+       } else if (IS_UNUSED != IS_UNUSED) {
 
-               function_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-               if (IS_VAR != IS_CONST) {
+
+               function_name = NULL;
+               if (IS_UNUSED != IS_CONST) {
                        if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                                if (UNEXPECTED(EG(exception) != NULL)) {
                                        HANDLE_EXCEPTION();
@@ -6536,12 +6376,12 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_VAR_HANDLER(ZE
                if (ce->get_static_method) {
                        fbc = ce->get_static_method(ce, Z_STR_P(function_name) TSRMLS_CC);
                } else {
-                       fbc = zend_std_get_static_method(ce, Z_STR_P(function_name), ((IS_VAR == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
+                       fbc = zend_std_get_static_method(ce, Z_STR_P(function_name), ((IS_UNUSED == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
                }
                if (UNEXPECTED(fbc == NULL)) {
                        zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name->val, Z_STRVAL_P(function_name));
                }
-               if (IS_VAR == IS_CONST &&
+               if (IS_UNUSED == IS_CONST &&
                    EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
                    EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0)) {
                        if (IS_CONST == IS_CONST) {
@@ -6550,8 +6390,8 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_VAR_HANDLER(ZE
                                CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), ce, fbc);
                        }
                }
-               if (IS_VAR != IS_CONST) {
-                       zval_ptr_dtor_nogc(free_op2);
+               if (IS_UNUSED != IS_CONST) {
+
                }
        } else {
                if (UNEXPECTED(ce->constructor == NULL)) {
@@ -6600,7 +6440,7 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_VAR_HANDLER(ZE
        EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
                fbc, opline->extended_value, ce, object, EX(call) TSRMLS_CC);
 
-       if (IS_VAR == IS_UNUSED) {
+       if (IS_UNUSED == IS_UNUSED) {
                EX(call)->return_value = NULL;
        }
 
@@ -6608,77 +6448,7 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_VAR_HANDLER(ZE
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_USER_CALL_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
-       zval *function_name = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
-       zend_fcall_info_cache fcc;
-       char *error = NULL;
-       zend_function *func;
-       zend_class_entry *called_scope;
-       zend_object *object;
-
-       if (zend_is_callable_ex(function_name, NULL, 0, NULL, &fcc, &error TSRMLS_CC)) {
-               if (error) {
-                       efree(error);
-               }
-               func = fcc.function_handler;
-               if (func->common.fn_flags & ZEND_ACC_CLOSURE) {
-                       /* Delay closure destruction until its invocation */
-                       func->common.prototype = (zend_function*)Z_OBJ_P(function_name);
-                       Z_ADDREF_P(function_name);
-               }
-               called_scope = fcc.called_scope;
-               object = fcc.object;
-               if (object) {
-                       GC_REFCOUNT(object)++; /* For $this pointer */
-               } else if (func->common.scope &&
-                          !(func->common.fn_flags & ZEND_ACC_STATIC)) {
-                       if (func->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
-                               zend_error(E_STRICT,
-                               "Non-static method %s::%s() should not be called statically",
-                               func->common.scope->name->val, func->common.function_name->val);
-                       } else {
-                               zend_error_noreturn(
-                                       E_ERROR,
-                                       "Non-static method %s::%s() cannot be called statically",
-                                       func->common.scope->name->val, func->common.function_name->val);
-                       }
-               }
-       } else {
-               zend_error(E_WARNING, "%s() expects parameter 1 to be a valid callback, %s", Z_STRVAL_P(opline->op1.zv), error);
-               efree(error);
-               func = (zend_function*)&zend_pass_function;
-               called_scope = NULL;
-               object = NULL;
-       }
-
-       EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
-               func, opline->extended_value, called_scope, object, EX(call) TSRMLS_CC);
-
-       zval_ptr_dtor_nogc(free_op2);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_CASE_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
-       zval *result = EX_VAR(opline->result.var);
-
-       SAVE_OPLINE();
-       fast_equal_function(result,
-                opline->op1.zv,
-                _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
-
-       zval_ptr_dtor_nogc(free_op2);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
@@ -6713,9 +6483,9 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_VAR_HANDLER(ZEND_OPC
                }
        }
 
-       if (IS_VAR != IS_UNUSED) {
-               zend_free_op free_op2;
-               zval *offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+       if (IS_UNUSED != IS_UNUSED) {
+
+               zval *offset = NULL;
                zend_string *str;
                zend_ulong hval;
 
@@ -6731,7 +6501,7 @@ num_index:
                                break;
                        case IS_STRING:
                                str = Z_STR_P(offset);
-                               if (IS_VAR != IS_CONST) {
+                               if (IS_UNUSED != IS_CONST) {
                                        if (ZEND_HANDLE_NUMERIC(str, hval)) {
                                                goto num_index;
                                        }
@@ -6758,7 +6528,7 @@ str_index:
                                /* do nothing */
                                break;
                }
-               zval_ptr_dtor_nogc(free_op2);
+
        } else {
                zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
        }
@@ -6766,7 +6536,7 @@ str_index:
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        zval *array;
        uint32_t size;
@@ -6792,12 +6562,12 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HAN
                ZEND_VM_NEXT_OPCODE();
 #if 0 || IS_CONST != IS_UNUSED
        } else {
-               return ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 #endif
        }
 }
 
-static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zval tmp, *varname;
@@ -6806,7 +6576,7 @@ static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HAND
 
        SAVE_OPLINE();
        if (IS_CONST == IS_CV &&
-           IS_VAR == IS_UNUSED &&
+           IS_UNUSED == IS_UNUSED &&
            (opline->extended_value & ZEND_QUICK_SET)) {
                zval *var = EX_VAR(opline->op1.var);
 
@@ -6835,10 +6605,10 @@ static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HAND
                varname = &tmp;
        }
 
-       if (IS_VAR != IS_UNUSED) {
+       if (IS_UNUSED != IS_UNUSED) {
                zend_class_entry *ce;
 
-               if (IS_VAR == IS_CONST) {
+               if (IS_UNUSED == IS_CONST) {
                        if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
                                ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
                        } else {
@@ -6872,14 +6642,14 @@ static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HAND
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zval *value;
 
        SAVE_OPLINE();
        if (IS_CONST == IS_CV &&
-           IS_VAR == IS_UNUSED &&
+           IS_UNUSED == IS_UNUSED &&
            (opline->extended_value & ZEND_QUICK_SET)) {
                value = EX_VAR(opline->op1.var);
                if (opline->extended_value & ZEND_ISSET) {
@@ -6902,10 +6672,10 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_CONST_VAR_HANDLER(ZEND_OPC
                        varname = &tmp;
                }
 
-               if (IS_VAR != IS_UNUSED) {
+               if (IS_UNUSED != IS_UNUSED) {
                        zend_class_entry *ce;
 
-                       if (IS_VAR == IS_CONST) {
+                       if (IS_UNUSED == IS_CONST) {
                                if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
                                        ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
                                } else {
@@ -6943,154 +6713,32 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_CONST_VAR_HANDLER(ZEND_OPC
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_DECLARE_LAMBDA_FUNCTION_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
-       zval *container;
-       int result;
-       zend_ulong hval;
-       zval *offset;
+       zval *zfunc;
+       int closure_is_static, closure_is_being_defined_inside_static_context;
 
        SAVE_OPLINE();
-       container = opline->op1.zv;
-       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if (IS_CONST != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
-               HashTable *ht = Z_ARRVAL_P(container);
-               zval *value;
-               zend_string *str;
-
-isset_again:
-               if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
-                       str = Z_STR_P(offset);
-                       if (IS_VAR != IS_CONST) {
-                               if (ZEND_HANDLE_NUMERIC(str, hval)) {
-                                       goto num_index_prop;
-                               }
-                       }
-str_index_prop:
-                       value = zend_hash_find_ind(ht, str);
-               } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
-                       hval = Z_LVAL_P(offset);
-num_index_prop:
-                       value = zend_hash_index_find(ht, hval);
-               } else {
-                       switch (Z_TYPE_P(offset)) {
-                               case IS_DOUBLE:
-                                       hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                                       goto num_index_prop;
-                               case IS_NULL:
-                                       str = STR_EMPTY_ALLOC();
-                                       goto str_index_prop;
-                               case IS_FALSE:
-                                       hval = 0;
-                                       goto num_index_prop;
-                               case IS_TRUE:
-                                       hval = 1;
-                                       goto num_index_prop;
-                               case IS_RESOURCE:
-                                       hval = Z_RES_HANDLE_P(offset);
-                                       goto num_index_prop;
-                               case IS_REFERENCE:
-                                       offset = Z_REFVAL_P(offset);
-                                       goto isset_again;
-                               default:
-                                       zend_error(E_WARNING, "Illegal offset type in isset or empty");
-                                       value = NULL;
-                                       break;
-                       }
-               }
-
-               if (opline->extended_value & ZEND_ISSET) {
-                       /* > IS_NULL means not IS_UNDEF and not IS_NULL */
-                       result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
-               }
-       } else if (IS_CONST == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
-                       result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
-               } else {
-                       zend_error(E_NOTICE, "Trying to check element of non-array");
-                       result = 0;
-               }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
-               }
-       } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
-               zval tmp;
-
-               result = 0;
-               if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
-                       if (IS_VAR == IS_CV || IS_VAR == IS_VAR) {
-                               ZVAL_DEREF(offset);
-                       }
-                       if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
-                                       || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
-                                               && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
-                               ZVAL_DUP(&tmp, offset);
-                               convert_to_long(&tmp);
-                               offset = &tmp;
-                       }
-               }
-               if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
-                       if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
-                               if ((opline->extended_value & ZEND_ISSET) ||
-                                   Z_STRVAL_P(container)[offset->value.lval] != '0') {
-                                       result = 1;
-                               }
-                       }
-               }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
-               }
-       } else {
-               result = ((opline->extended_value & ZEND_ISSET) == 0);
+       if (UNEXPECTED((zfunc = zend_hash_find(EG(function_table), Z_STR_P(opline->op1.zv))) == NULL) ||
+           UNEXPECTED(Z_FUNC_P(zfunc)->type != ZEND_USER_FUNCTION)) {
+               zend_error_noreturn(E_ERROR, "Base lambda function for closure not found");
        }
 
-       zval_ptr_dtor_nogc(free_op2);
-       ZVAL_BOOL(EX_VAR(opline->result.var), result);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
-       zval *container;
-       int result;
-       zval *offset;
-
-       SAVE_OPLINE();
-       container = opline->op1.zv;
-       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
-       if (IS_CONST == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
-                       result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
-               } else {
-                       zend_error(E_NOTICE, "Trying to check property of non-object");
-                       result = 0;
-               }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
-               }
+       closure_is_static = Z_FUNC_P(zfunc)->common.fn_flags & ZEND_ACC_STATIC;
+       closure_is_being_defined_inside_static_context = EX(func)->common.fn_flags & ZEND_ACC_STATIC;
+       if (closure_is_static || closure_is_being_defined_inside_static_context) {
+               zend_create_closure(EX_VAR(opline->result.var), Z_FUNC_P(zfunc), EX(called_scope), NULL TSRMLS_CC);
        } else {
-               result = ((opline->extended_value & ZEND_ISSET) == 0);
+               zend_create_closure(EX_VAR(opline->result.var), Z_FUNC_P(zfunc), EG(scope), Z_OBJ(EX(This)) ? &EX(This) : NULL TSRMLS_CC);
        }
 
-       zval_ptr_dtor_nogc(free_op2);
-       ZVAL_BOOL(EX_VAR(opline->result.var), result);
-
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_YIELD_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_YIELD_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
@@ -7171,21 +6819,21 @@ static int ZEND_FASTCALL  ZEND_YIELD_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_
        }
 
        /* Set the new yielded key */
-       if (IS_VAR != IS_UNUSED) {
-               zend_free_op free_op2;
-               zval *key = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+       if (IS_UNUSED != IS_UNUSED) {
+
+               zval *key = NULL;
 
                /* Consts, temporary variables and references need copying */
-               if (IS_VAR == IS_CONST) {
+               if (IS_UNUSED == IS_CONST) {
                        ZVAL_DUP(&generator->key, key);
-               } else if (IS_VAR == IS_TMP_VAR) {
+               } else if (IS_UNUSED == IS_TMP_VAR) {
                        ZVAL_COPY_VALUE(&generator->key, key);
-               } else if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && Z_ISREF_P(key)) {
+               } else if ((IS_UNUSED == IS_VAR || IS_UNUSED == IS_CV) && Z_ISREF_P(key)) {
                        ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
-                       zval_ptr_dtor_nogc(free_op2);
+
                } else {
                        ZVAL_COPY_VALUE(&generator->key, key);
-                       if (IS_VAR == IS_CV) {
+                       if (IS_UNUSED == IS_CV) {
                                if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
                        }
                }
@@ -7221,1146 +6869,402 @@ static int ZEND_FASTCALL  ZEND_YIELD_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_
        ZEND_VM_RETURN();
 }
 
-static int ZEND_FASTCALL  ZEND_POW_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ADD_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
+
 
        SAVE_OPLINE();
-       pow_function(EX_VAR(opline->result.var),
+       fast_add_function(EX_VAR(opline->result.var),
                opline->op1.zv,
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
 
-       zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CONST_UNUSED(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SUB_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *varname;
-       zval *retval;
-       zend_string *name;
-       HashTable *target_symbol_table;
 
        SAVE_OPLINE();
-       varname = opline->op1.zv;
-
-       if (IS_CONST == IS_CONST) {
-               name = Z_STR_P(varname);
-       } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
-               name = Z_STR_P(varname);
-               zend_string_addref(name);
-       } else {
-               name = zval_get_string(varname);
-       }
+       fast_sub_function(EX_VAR(opline->result.var),
+               opline->op1.zv,
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
-       if (IS_UNUSED != IS_UNUSED) {
-               zend_class_entry *ce;
 
-               if (IS_UNUSED == IS_CONST) {
-                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                       } else {
-                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                               if (UNEXPECTED(ce == NULL)) {
-                                       if (IS_CONST != IS_CONST) {
-                                               zend_string_release(name);
-                                       }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-                                       CHECK_EXCEPTION();
-                                       ZEND_VM_NEXT_OPCODE();
-                               }
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
-                       }
-               } else {
-                       ce = Z_CE_P(EX_VAR(opline->op2.var));
-               }
-               retval = zend_std_get_static_property(ce, name, 0, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+static int ZEND_FASTCALL  ZEND_MUL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       } else {
-               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-               retval = zend_hash_find(target_symbol_table, name);
-               if (retval == NULL) {
-                       switch (type) {
-                               case BP_VAR_R:
-                               case BP_VAR_UNSET:
-                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                       /* break missing intentionally */
-                               case BP_VAR_IS:
-                                       retval = &EG(uninitialized_zval);
-                                       break;
-                               case BP_VAR_RW:
-                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                       /* break missing intentionally */
-                               case BP_VAR_W:
-                                       retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
-                                       break;
-                               EMPTY_SWITCH_DEFAULT_CASE()
-                       }
-               /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
-               } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
-                       retval = Z_INDIRECT_P(retval);
-                       if (Z_TYPE_P(retval) == IS_UNDEF) {
-                               switch (type) {
-                                       case BP_VAR_R:
-                                       case BP_VAR_UNSET:
-                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                               /* break missing intentionally */
-                                       case BP_VAR_IS:
-                                               retval = &EG(uninitialized_zval);
-                                               break;
-                                       case BP_VAR_RW:
-                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                               /* break missing intentionally */
-                                       case BP_VAR_W:
-                                               ZVAL_NULL(retval);
-                                               break;
-                                       EMPTY_SWITCH_DEFAULT_CASE()
-                               }
-                       }
-               }
-               if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
-                       if (Z_CONSTANT_P(retval)) {
-                               zval_update_constant(retval, 1 TSRMLS_CC);
-                       }
-               } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
 
-               }
-       }
+       SAVE_OPLINE();
+       fast_mul_function(EX_VAR(opline->result.var),
+               opline->op1.zv,
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
-       if (IS_CONST != IS_CONST) {
-               zend_string_release(name);
-       }
 
-       ZEND_ASSERT(retval != NULL);
-       if (type == BP_VAR_R || type == BP_VAR_IS) {
-               if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
-                       ZVAL_UNREF(retval);
-               }
-               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-       } else {
-               ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
-       }
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_R_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_DIV_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+       USE_OPLINE
 
-static int ZEND_FASTCALL  ZEND_FETCH_W_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
 
-static int ZEND_FASTCALL  ZEND_FETCH_RW_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       SAVE_OPLINE();
+       fast_div_function(EX_VAR(opline->result.var),
+               opline->op1.zv,
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_FUNC_ARG_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_MOD_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-               return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else {
-               return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
+
+       SAVE_OPLINE();
+       fast_mod_function(EX_VAR(opline->result.var),
+               opline->op1.zv,
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_UNSET_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       USE_OPLINE
+
+
+       SAVE_OPLINE();
+       shift_left_function(EX_VAR(opline->result.var),
+               opline->op1.zv,
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_IS_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SR_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_var_address_helper_SPEC_CONST_UNUSED(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       USE_OPLINE
+
+
+       SAVE_OPLINE();
+       shift_right_function(EX_VAR(opline->result.var),
+               opline->op1.zv,
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *container;
-       zend_free_op free_op1;
+
 
        SAVE_OPLINE();
+       concat_function(EX_VAR(opline->result.var),
+               opline->op1.zv,
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-        if (IS_CONST == IS_CONST || IS_CONST == IS_TMP_VAR) {
-            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
-        }
-               container = NULL;
-               if (IS_CONST == IS_VAR && UNEXPECTED(container == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-               }
-               ZVAL_DEREF(container);
-               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
-               if (IS_CONST == IS_VAR && READY_TO_DESTROY(free_op1)) {
-                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-               }
 
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       } else {
-               if (IS_UNUSED == IS_UNUSED) {
-                       zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
-               }
-               container = opline->op1.zv;
-               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
+
+       SAVE_OPLINE();
+       fast_is_identical_function(EX_VAR(opline->result.var),
+               opline->op1.zv,
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
-       }
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *function_name;
-       zend_class_entry *ce;
-       zend_object *object;
-       zend_function *fbc;
+
+       zval *result = EX_VAR(opline->result.var);
 
        SAVE_OPLINE();
+       fast_is_not_identical_function(result,
+               opline->op1.zv,
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
-       if (IS_CONST == IS_CONST) {
-               /* no function found. try a static method in class */
-               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv))) {
-                       ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv));
-               } else {
-                       ce = zend_fetch_class_by_name(Z_STR_P(opline->op1.zv), opline->op1.zv + 1, ZEND_FETCH_CLASS_DEFAULT TSRMLS_CC);
-                       if (UNEXPECTED(EG(exception) != NULL)) {
-                               HANDLE_EXCEPTION();
-                       }
-                       if (UNEXPECTED(ce == NULL)) {
-                               zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
-                       }
-                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op1.zv), ce);
-               }
-       } else {
-               ce = Z_CE_P(EX_VAR(opline->op1.var));
-       }
 
-       if (IS_CONST == IS_CONST &&
-           IS_UNUSED == IS_CONST &&
-           CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-               fbc = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-       } else if (IS_CONST != IS_CONST &&
-                  IS_UNUSED == IS_CONST &&
-                  (fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce))) {
-               /* do nothing */
-       } else if (IS_UNUSED != IS_UNUSED) {
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
+static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-               function_name = NULL;
-               if (IS_UNUSED != IS_CONST) {
-                       if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
-                               if (UNEXPECTED(EG(exception) != NULL)) {
-                                       HANDLE_EXCEPTION();
-                               }
-                               zend_error_noreturn(E_ERROR, "Function name must be a string");
-                       }
-               }
+       zval *result = EX_VAR(opline->result.var);
 
-               if (ce->get_static_method) {
-                       fbc = ce->get_static_method(ce, Z_STR_P(function_name) TSRMLS_CC);
-               } else {
-                       fbc = zend_std_get_static_method(ce, Z_STR_P(function_name), ((IS_UNUSED == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
-               }
-               if (UNEXPECTED(fbc == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name->val, Z_STRVAL_P(function_name));
-               }
-               if (IS_UNUSED == IS_CONST &&
-                   EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
-                   EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0)) {
-                       if (IS_CONST == IS_CONST) {
-                               CACHE_PTR(Z_CACHE_SLOT_P(function_name), fbc);
-                       } else {
-                               CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), ce, fbc);
-                       }
-               }
-               if (IS_UNUSED != IS_CONST) {
+       SAVE_OPLINE();
+       fast_equal_function(result,
+               opline->op1.zv,
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
-               }
-       } else {
-               if (UNEXPECTED(ce->constructor == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot call constructor");
-               }
-               if (Z_OBJ(EX(This)) && Z_OBJ(EX(This))->ce != ce->constructor->common.scope && (ce->constructor->common.fn_flags & ZEND_ACC_PRIVATE)) {
-                       zend_error_noreturn(E_ERROR, "Cannot call private %s::__construct()", ce->name->val);
-               }
-               fbc = ce->constructor;
-       }
 
-       object = NULL;
-       if (!(fbc->common.fn_flags & ZEND_ACC_STATIC)) {
-               if (Z_OBJ(EX(This))) {
-                       object = Z_OBJ(EX(This));
-                       GC_REFCOUNT(object)++;
-               }
-               if (!object ||
-                   !instanceof_function(object->ce, ce TSRMLS_CC)) {
-                   /* We are calling method of the other (incompatible) class,
-                      but passing $this. This is done for compatibility with php-4. */
-                       if (fbc->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
-                               zend_error(
-                                       object ? E_DEPRECATED : E_STRICT,
-                                       "Non-static method %s::%s() should not be called statically%s",
-                                       fbc->common.scope->name->val, fbc->common.function_name->val,
-                                       object ? ", assuming $this from incompatible context" : "");
-                       } else {
-                               /* An internal function assumes $this is present and won't check that. So PHP would crash by allowing the call. */
-                               zend_error_noreturn(
-                                       E_ERROR,
-                                       "Non-static method %s::%s() cannot be called statically%s",
-                                       fbc->common.scope->name->val, fbc->common.function_name->val,
-                                       object ? ", assuming $this from incompatible context" : "");
-                       }
-               }
-       }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       if (IS_CONST != IS_CONST) {
-               /* previous opcode is ZEND_FETCH_CLASS */
-               if ((opline-1)->extended_value == ZEND_FETCH_CLASS_PARENT || (opline-1)->extended_value == ZEND_FETCH_CLASS_SELF) {
-                       ce = EX(called_scope);
-               }
-       }
+static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
-               fbc, opline->extended_value, ce, object, EX(call) TSRMLS_CC);
+       zval *result = EX_VAR(opline->result.var);
+
+       SAVE_OPLINE();
+       fast_not_equal_function(result,
+               opline->op1.zv,
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
-       if (IS_UNUSED == IS_UNUSED) {
-               EX(call)->return_value = NULL;
-       }
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *expr_ptr, new_expr;
+       zval *result = EX_VAR(opline->result.var);
 
        SAVE_OPLINE();
-       if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) &&
-           (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
-               expr_ptr = NULL;
-               if (IS_CONST == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
-               }
-               ZVAL_MAKE_REF(expr_ptr);
-               Z_ADDREF_P(expr_ptr);
-
-       } else {
-               expr_ptr = opline->op1.zv;
-               if (IS_CONST == IS_TMP_VAR) {
-                       ZVAL_COPY_VALUE(&new_expr, expr_ptr);
-                       expr_ptr = &new_expr;
-               } else if (IS_CONST == IS_CONST) {
-                       if (!Z_IMMUTABLE_P(expr_ptr)) {
-                               ZVAL_DUP(&new_expr, expr_ptr);
-                               expr_ptr = &new_expr;
-                       }
-               } else if ((IS_CONST == IS_CV || IS_CONST == IS_VAR) && Z_ISREF_P(expr_ptr)) {
-                       expr_ptr = Z_REFVAL_P(expr_ptr);
-                       if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
-
-               } else if (IS_CONST == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
-                       Z_ADDREF_P(expr_ptr);
-               }
-       }
-
-       if (IS_UNUSED != IS_UNUSED) {
-
-               zval *offset = NULL;
-               zend_string *str;
-               zend_ulong hval;
+       fast_is_smaller_function(result,
+               opline->op1.zv,
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
-add_again:
-               switch (Z_TYPE_P(offset)) {
-                       case IS_DOUBLE:
-                               hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                               goto num_index;
-                       case IS_LONG:
-                               hval = Z_LVAL_P(offset);
-num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
-                               break;
-                       case IS_STRING:
-                               str = Z_STR_P(offset);
-                               if (IS_UNUSED != IS_CONST) {
-                                       if (ZEND_HANDLE_NUMERIC(str, hval)) {
-                                               goto num_index;
-                                       }
-                               }
-str_index:
-                               zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
-                               break;
-                       case IS_NULL:
-                               str = STR_EMPTY_ALLOC();
-                               goto str_index;
-                       case IS_FALSE:
-                               hval = 0;
-                               goto num_index;
-                       case IS_TRUE:
-                               hval = 1;
-                               goto num_index;
-                       case IS_REFERENCE:
-                               offset = Z_REFVAL_P(offset);
-                               goto add_again;
-                               break;
-                       default:
-                               zend_error(E_WARNING, "Illegal offset type");
-                               zval_ptr_dtor(expr_ptr);
-                               /* do nothing */
-                               break;
-               }
 
-       } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
-       }
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       zval *array;
-       uint32_t size;
-       USE_OPLINE
-
-       array = EX_VAR(opline->result.var);
-       if (IS_CONST != IS_UNUSED) {
-               size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
-       } else {
-               size = 0;
-       }
-       ZVAL_NEW_ARR(array);
-       zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
-
-       if (IS_CONST != IS_UNUSED) {
-               /* Explicitly initialize array as not-packed if flag is set */
-               if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
-                       zend_hash_real_init(Z_ARRVAL_P(array), 0);
-               }
-       }
-
-       if (IS_CONST == IS_UNUSED) {
-               ZEND_VM_NEXT_OPCODE();
-#if 0 || IS_CONST != IS_UNUSED
-       } else {
-               return ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-#endif
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval tmp, *varname;
-       HashTable *target_symbol_table;
 
+       zval *result = EX_VAR(opline->result.var);
 
        SAVE_OPLINE();
-       if (IS_CONST == IS_CV &&
-           IS_UNUSED == IS_UNUSED &&
-           (opline->extended_value & ZEND_QUICK_SET)) {
-               zval *var = EX_VAR(opline->op1.var);
-
-               if (Z_REFCOUNTED_P(var)) {
-                       zend_refcounted *garbage = Z_COUNTED_P(var);
-
-                       if (!--GC_REFCOUNT(garbage)) {
-                               ZVAL_UNDEF(var);
-                               _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
-                       } else {
-                               GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
-                               ZVAL_UNDEF(var);
-                       }
-               } else {
-                       ZVAL_UNDEF(var);
-               }
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
-
-       varname = opline->op1.zv;
-
-       ZVAL_UNDEF(&tmp);
-       if (IS_CONST != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-               ZVAL_STR(&tmp, zval_get_string(varname));
-               varname = &tmp;
-       }
-
-       if (IS_UNUSED != IS_UNUSED) {
-               zend_class_entry *ce;
-
-               if (IS_UNUSED == IS_CONST) {
-                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                       } else {
-                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                               if (UNEXPECTED(EG(exception) != NULL)) {
-                                       if (IS_CONST != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-                                               zend_string_release(Z_STR(tmp));
-                                       }
-
-                                       HANDLE_EXCEPTION();
-                               }
-                               if (UNEXPECTED(ce == NULL)) {
-                                       zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
-                               }
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
-                       }
-               } else {
-                       ce = Z_CE_P(EX_VAR(opline->op2.var));
-               }
-               zend_std_unset_static_property(ce, Z_STR_P(varname), ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
-       } else {
-               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-               zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
-       }
+       fast_is_smaller_or_equal_function(result,
+               opline->op1.zv,
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
-       if (IS_CONST != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-               zend_string_release(Z_STR(tmp));
-       }
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *value;
-
-       SAVE_OPLINE();
-       if (IS_CONST == IS_CV &&
-           IS_UNUSED == IS_UNUSED &&
-           (opline->extended_value & ZEND_QUICK_SET)) {
-               value = EX_VAR(opline->op1.var);
-               if (opline->extended_value & ZEND_ISSET) {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               !i_zend_is_true(value TSRMLS_CC));
-                       CHECK_EXCEPTION();
-               }
-               ZEND_VM_NEXT_OPCODE();
-       } else {
-
-               zval tmp, *varname = opline->op1.zv;
-
-               ZVAL_UNDEF(&tmp);
-               if (IS_CONST != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-                       ZVAL_STR(&tmp, zval_get_string(varname));
-                       varname = &tmp;
-               }
-
-               if (IS_UNUSED != IS_UNUSED) {
-                       zend_class_entry *ce;
-
-                       if (IS_UNUSED == IS_CONST) {
-                               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                                       ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                               } else {
-                                       ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                                       if (UNEXPECTED(ce == NULL)) {
-                                               CHECK_EXCEPTION();
-                                               ZEND_VM_NEXT_OPCODE();
-                                       }
-                                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
-                               }
-                       } else {
-                               ce = Z_CE_P(EX_VAR(opline->op2.var));
-                       }
-                       value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
-               } else {
-                       HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-                       value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
-               }
 
-               if (IS_CONST != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-                       zend_string_release(Z_STR(tmp));
-               }
-
-               if (opline->extended_value & ZEND_ISSET) {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               value && Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               !value || !i_zend_is_true(value TSRMLS_CC));
-               }
-
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_DECLARE_LAMBDA_FUNCTION_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *zfunc;
-       int closure_is_static, closure_is_being_defined_inside_static_context;
 
        SAVE_OPLINE();
+       bitwise_or_function(EX_VAR(opline->result.var),
+               opline->op1.zv,
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
-       if (UNEXPECTED((zfunc = zend_hash_find(EG(function_table), Z_STR_P(opline->op1.zv))) == NULL) ||
-           UNEXPECTED(Z_FUNC_P(zfunc)->type != ZEND_USER_FUNCTION)) {
-               zend_error_noreturn(E_ERROR, "Base lambda function for closure not found");
-       }
-
-       closure_is_static = Z_FUNC_P(zfunc)->common.fn_flags & ZEND_ACC_STATIC;
-       closure_is_being_defined_inside_static_context = EX(func)->common.fn_flags & ZEND_ACC_STATIC;
-       if (closure_is_static || closure_is_being_defined_inside_static_context) {
-               zend_create_closure(EX_VAR(opline->result.var), Z_FUNC_P(zfunc), EX(called_scope), NULL TSRMLS_CC);
-       } else {
-               zend_create_closure(EX_VAR(opline->result.var), Z_FUNC_P(zfunc), EG(scope), Z_OBJ(EX(This)) ? &EX(This) : NULL TSRMLS_CC);
-       }
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_YIELD_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       /* The generator object is stored in EX(return_value) */
-       zend_generator *generator = (zend_generator *) EX(return_value);
-
-       if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
-               zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
-       }
-
-       /* Destroy the previously yielded value */
-       zval_ptr_dtor(&generator->value);
-
-       /* Destroy the previously yielded key */
-       zval_ptr_dtor(&generator->key);
-
-       /* Set the new yielded value */
-       if (IS_CONST != IS_UNUSED) {
-
-
-               if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
-                       /* Constants and temporary variables aren't yieldable by reference,
-                        * but we still allow them with a notice. */
-                       if (IS_CONST == IS_CONST || IS_CONST == IS_TMP_VAR) {
-                               zval *value;
-
-                               zend_error(E_NOTICE, "Only variable references should be yielded by reference");
-
-                               value = opline->op1.zv;
-                               ZVAL_COPY_VALUE(&generator->value, value);
-                               if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
-
-                               /* Temporary variables don't need ctor copying */
-                               if (IS_CONST != IS_TMP_VAR) {
-                                       zval_opt_copy_ctor(&generator->value);
-                               }
-                       } else {
-                               zval *value_ptr = NULL;
-
-                               if (IS_CONST == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
-                                       zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
-                               }
-
-                               /* If a function call result is yielded and the function did
-                                * not return by reference we throw a notice. */
-                               if (IS_CONST == IS_VAR &&
-                                   (value_ptr == &EG(uninitialized_zval) ||
-                                    (opline->extended_value == ZEND_RETURNS_FUNCTION &&
-                                     !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
-                                       zend_error(E_NOTICE, "Only variable references should be yielded by reference");
-                               } else {
-                                       ZVAL_MAKE_REF(value_ptr);
-                               }
-                               ZVAL_COPY(&generator->value, value_ptr);
-
-                       }
-               } else {
-                       zval *value = opline->op1.zv;
-
-                       /* Consts, temporary variables and references need copying */
-                       if (IS_CONST == IS_CONST) {
-                               ZVAL_DUP(&generator->value, value);
-                       } else if (IS_CONST == IS_TMP_VAR) {
-                               ZVAL_COPY_VALUE(&generator->value, value);
-            } else if ((IS_CONST == IS_CV || IS_CONST == IS_VAR) && Z_ISREF_P(value)) {
-                               ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
-
-                       } else {
-                               ZVAL_COPY_VALUE(&generator->value, value);
-                               if (IS_CONST == IS_CV) {
-                                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
-                               }
-                       }
-               }
-       } else {
-               /* If no value was specified yield null */
-               ZVAL_NULL(&generator->value);
-       }
-
-       /* Set the new yielded key */
-       if (IS_UNUSED != IS_UNUSED) {
-
-               zval *key = NULL;
-
-               /* Consts, temporary variables and references need copying */
-               if (IS_UNUSED == IS_CONST) {
-                       ZVAL_DUP(&generator->key, key);
-               } else if (IS_UNUSED == IS_TMP_VAR) {
-                       ZVAL_COPY_VALUE(&generator->key, key);
-               } else if ((IS_UNUSED == IS_VAR || IS_UNUSED == IS_CV) && Z_ISREF_P(key)) {
-                       ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
-
-               } else {
-                       ZVAL_COPY_VALUE(&generator->key, key);
-                       if (IS_UNUSED == IS_CV) {
-                               if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
-                       }
-               }
-
-               if (Z_TYPE(generator->key) == IS_LONG
-                   && Z_LVAL(generator->key) > generator->largest_used_integer_key
-               ) {
-                       generator->largest_used_integer_key = Z_LVAL(generator->key);
-               }
-       } else {
-               /* If no key was specified we use auto-increment keys */
-               generator->largest_used_integer_key++;
-               ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
-       }
-
-       if (RETURN_VALUE_USED(opline)) {
-               /* If the return value of yield is used set the send
-                * target and initialize it to NULL */
-               generator->send_target = EX_VAR(opline->result.var);
-               ZVAL_NULL(generator->send_target);
-       } else {
-               generator->send_target = NULL;
-       }
-
-       /* We increment to the next op, so we are at the correct position when the
-        * generator is resumed. */
-       ZEND_VM_INC_OPCODE();
-
-       /* The GOTO VM uses a local opline variable. We need to set the opline
-        * variable in execute_data so we don't resume at an old position. */
-       SAVE_OPLINE();
-
-       ZEND_VM_RETURN();
-}
-
-static int ZEND_FASTCALL  ZEND_ADD_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
 
        SAVE_OPLINE();
-       fast_add_function(EX_VAR(opline->result.var),
+       bitwise_and_function(EX_VAR(opline->result.var),
                opline->op1.zv,
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_SUB_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
 
        SAVE_OPLINE();
-       fast_sub_function(EX_VAR(opline->result.var),
+       bitwise_xor_function(EX_VAR(opline->result.var),
                opline->op1.zv,
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_MUL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
 
        SAVE_OPLINE();
-       fast_mul_function(EX_VAR(opline->result.var),
+       boolean_xor_function(EX_VAR(opline->result.var),
                opline->op1.zv,
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_DIV_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
+       zval *container;
 
        SAVE_OPLINE();
-       fast_div_function(EX_VAR(opline->result.var),
-               opline->op1.zv,
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+       container = opline->op1.zv;
+       zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
 
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_MOD_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
+       zval *container;
 
        SAVE_OPLINE();
-       fast_mod_function(EX_VAR(opline->result.var),
-               opline->op1.zv,
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+       container = opline->op1.zv;
+       zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
 
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_SL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
+       zval *container;
+       zend_free_op free_op1;
 
        SAVE_OPLINE();
-       shift_left_function(EX_VAR(opline->result.var),
-               opline->op1.zv,
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+        if (IS_CONST == IS_CONST || IS_CONST == IS_TMP_VAR) {
+            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+        }
+               container = NULL;
+               if (IS_CONST == IS_VAR && UNEXPECTED(container == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+               }
+               ZVAL_DEREF(container);
+               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
+               if (IS_CONST == IS_VAR && READY_TO_DESTROY(free_op1)) {
+                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+               }
+
+
+       } else {
+               if (IS_CV == IS_UNUSED) {
+                       zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
+               }
+               container = opline->op1.zv;
+               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
 
 
+       }
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_SR_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
+       zval *container;
+
+       zval *offset;
 
        SAVE_OPLINE();
-       shift_right_function(EX_VAR(opline->result.var),
-               opline->op1.zv,
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+       container = opline->op1.zv;
+       offset  = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
 
+       if ((IS_CONST != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               zend_error(E_NOTICE, "Trying to get property of non-object");
+               ZVAL_NULL(EX_VAR(opline->result.var));
+       } else {
+               zval *retval;
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+               /* here we are sure we are dealing with an object */
+               do {
+                       if (IS_CV == IS_CONST &&
+                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
+                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
+                               zend_object *zobj = Z_OBJ_P(container);
 
-static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+                               if (EXPECTED(prop_info)) {
+                                       retval = OBJ_PROP(zobj, prop_info->offset);
+                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
+                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                                               break;
+                                       }
+                               } else if (EXPECTED(zobj->properties != NULL)) {
+                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
+                                       if (EXPECTED(retval)) {
+                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                                               break;
+                                       }
+                               }
+                       }
 
+                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
 
-       SAVE_OPLINE();
-       concat_function(EX_VAR(opline->result.var),
-               opline->op1.zv,
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+                       if (retval != EX_VAR(opline->result.var)) {
+                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                       }
+               } while (0);
+       }
 
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-
-       SAVE_OPLINE();
-       fast_is_identical_function(EX_VAR(opline->result.var),
-               opline->op1.zv,
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       zval *result = EX_VAR(opline->result.var);
-
-       SAVE_OPLINE();
-       fast_is_not_identical_function(result,
-               opline->op1.zv,
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       zval *result = EX_VAR(opline->result.var);
-
-       SAVE_OPLINE();
-       fast_equal_function(result,
-               opline->op1.zv,
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       zval *result = EX_VAR(opline->result.var);
-
-       SAVE_OPLINE();
-       fast_not_equal_function(result,
-               opline->op1.zv,
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       zval *result = EX_VAR(opline->result.var);
-
-       SAVE_OPLINE();
-       fast_is_smaller_function(result,
-               opline->op1.zv,
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       zval *result = EX_VAR(opline->result.var);
-
-       SAVE_OPLINE();
-       fast_is_smaller_or_equal_function(result,
-               opline->op1.zv,
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-
-       SAVE_OPLINE();
-       bitwise_or_function(EX_VAR(opline->result.var),
-               opline->op1.zv,
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-
-       SAVE_OPLINE();
-       bitwise_and_function(EX_VAR(opline->result.var),
-               opline->op1.zv,
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-
-       SAVE_OPLINE();
-       bitwise_xor_function(EX_VAR(opline->result.var),
-               opline->op1.zv,
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-
-       SAVE_OPLINE();
-       boolean_xor_function(EX_VAR(opline->result.var),
-               opline->op1.zv,
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       zval *container;
-
-       SAVE_OPLINE();
-       container = opline->op1.zv;
-       zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
-
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       zval *container;
-
-       SAVE_OPLINE();
-       container = opline->op1.zv;
-       zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
-
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *container;
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-        if (IS_CONST == IS_CONST || IS_CONST == IS_TMP_VAR) {
-            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
-        }
-               container = NULL;
-               if (IS_CONST == IS_VAR && UNEXPECTED(container == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-               }
-               ZVAL_DEREF(container);
-               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
-               if (IS_CONST == IS_VAR && READY_TO_DESTROY(free_op1)) {
-                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-               }
-
-
-       } else {
-               if (IS_CV == IS_UNUSED) {
-                       zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
-               }
-               container = opline->op1.zv;
-               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
-
-
-       }
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       zval *container;
-
-       zval *offset;
-
-       SAVE_OPLINE();
-       container = opline->op1.zv;
-       offset  = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
-
-       if ((IS_CONST != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
-           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
-               zend_error(E_NOTICE, "Trying to get property of non-object");
-               ZVAL_NULL(EX_VAR(opline->result.var));
-       } else {
-               zval *retval;
-
-               /* here we are sure we are dealing with an object */
-               do {
-                       if (IS_CV == IS_CONST &&
-                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
-                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
-                               zend_object *zobj = Z_OBJ_P(container);
-
-                               if (EXPECTED(prop_info)) {
-                                       retval = OBJ_PROP(zobj, prop_info->offset);
-                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               } else if (EXPECTED(zobj->properties != NULL)) {
-                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
-                                       if (EXPECTED(retval)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               }
-                       }
-
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
-
-                       if (retval != EX_VAR(opline->result.var)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                       }
-               } while (0);
-       }
-
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
@@ -8889,7 +7793,7 @@ num_index_prop:
 
                result = 0;
                if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
-                       if (IS_CV == IS_CV || IS_CV == IS_VAR) {
+                       if (IS_CV & (IS_CV|IS_VAR)) {
                                ZVAL_DEREF(offset);
                        }
                        if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
@@ -9223,710 +8127,1117 @@ static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_CONST_TMPVAR_HANDLER(ZEN
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_BW_NOT_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_CONST_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
+
+       zval *container;
+       zend_free_op free_op2;
+       zval *offset;
 
        SAVE_OPLINE();
-       bitwise_not_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1) TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+       container = opline->op1.zv;
+       offset  = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-static int ZEND_FASTCALL  ZEND_BOOL_NOT_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
+       if ((IS_CONST != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               zend_error(E_NOTICE, "Trying to get property of non-object");
+               ZVAL_NULL(EX_VAR(opline->result.var));
+       } else {
+               zval *retval;
 
-       SAVE_OPLINE();
-       boolean_not_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1) TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+               /* here we are sure we are dealing with an object */
+               do {
+                       if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
+                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
+                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
+                               zend_object *zobj = Z_OBJ_P(container);
 
-static int ZEND_FASTCALL  ZEND_ECHO_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *z;
+                               if (EXPECTED(prop_info)) {
+                                       retval = OBJ_PROP(zobj, prop_info->offset);
+                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
+                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                                               break;
+                                       }
+                               } else if (EXPECTED(zobj->properties != NULL)) {
+                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
+                                       if (EXPECTED(retval)) {
+                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                                               break;
+                                       }
+                               }
+                       }
 
-       SAVE_OPLINE();
-       z = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
 
-       zend_print_variable(z TSRMLS_CC);
+                       if (retval != EX_VAR(opline->result.var)) {
+                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                       }
+               } while (0);
+       }
+
+       zval_ptr_dtor_nogc(free_op2);
 
-       zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_PRINT_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_CONST_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       ZVAL_LONG(EX_VAR(opline->result.var), 1);
-       return ZEND_ECHO_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_JMPZ_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *val;
+       zval *container;
+       zend_free_op free_op2;
+       zval *offset;
 
        SAVE_OPLINE();
-       val = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_TMP_VAR == IS_TMP_VAR) {
-               if (Z_TYPE_P(val) == IS_TRUE) {
-                       ZEND_VM_SET_OPCODE(opline + 1);
-                       ZEND_VM_CONTINUE();
-               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
-                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
-                       ZEND_VM_CONTINUE();
-               }
-       }
+       container = opline->op1.zv;
+       offset  = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if (i_zend_is_true(val TSRMLS_CC)) {
-               opline++;
+       if ((IS_CONST != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               ZVAL_NULL(EX_VAR(opline->result.var));
        } else {
-               opline = opline->op2.jmp_addr;
-       }
-       zval_ptr_dtor_nogc(free_op1);
-       if (UNEXPECTED(EG(exception) != NULL)) {
-               HANDLE_EXCEPTION();
-       }
-       ZEND_VM_JMP(opline);
-}
+               zval *retval;
 
-static int ZEND_FASTCALL  ZEND_JMPNZ_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *val;
+               /* here we are sure we are dealing with an object */
+               do {
+                       if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
+                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
+                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
+                               zend_object *zobj = Z_OBJ_P(container);
 
-       SAVE_OPLINE();
-       val = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+                               if (EXPECTED(prop_info)) {
+                                       retval = OBJ_PROP(zobj, prop_info->offset);
+                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
+                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                                               break;
+                                       }
+                               } else if (EXPECTED(zobj->properties != NULL)) {
+                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
+                                       if (EXPECTED(retval)) {
+                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                                               break;
+                                       }
+                               }
+                       }
 
-       if (IS_TMP_VAR == IS_TMP_VAR) {
-               if (Z_TYPE_P(val) == IS_TRUE) {
-                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
-                       ZEND_VM_CONTINUE();
-               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
-                       ZEND_VM_SET_OPCODE(opline + 1);
-                       ZEND_VM_CONTINUE();
-               }
-       }
+                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
 
-       if (i_zend_is_true(val TSRMLS_CC)) {
-               opline = opline->op2.jmp_addr;
-       } else {
-               opline++;
-       }
-       zval_ptr_dtor_nogc(free_op1);
-       if (UNEXPECTED(EG(exception) != NULL)) {
-               HANDLE_EXCEPTION();
+                       if (retval != EX_VAR(opline->result.var)) {
+                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                       }
+               } while (0);
        }
-       ZEND_VM_JMP(opline);
-}
-
-static int ZEND_FASTCALL  ZEND_JMPZNZ_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *val;
-
-       SAVE_OPLINE();
-       val = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
 
-       if (IS_TMP_VAR == IS_TMP_VAR) {
-               if (EXPECTED(Z_TYPE_P(val) == IS_TRUE)) {
-                       ZEND_VM_SET_RELATIVE_OPCODE(opline, opline->extended_value);
-                       ZEND_VM_CONTINUE();
-               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
-                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
-                       ZEND_VM_CONTINUE();
-               }
-       }
+       zval_ptr_dtor_nogc(free_op2);
 
-       if (i_zend_is_true(val TSRMLS_CC)) {
-               opline = (zend_op*)(((char*)opline) + opline->extended_value);
-       } else {
-               opline = opline->op2.jmp_addr;
-       }
-       zval_ptr_dtor_nogc(free_op1);
-       if (UNEXPECTED(EG(exception) != NULL)) {
-               HANDLE_EXCEPTION();
-       }
-       ZEND_VM_JMP(opline);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_JMPZ_EX_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CONST_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
-       zval *val;
+       zval *container;
 
-       SAVE_OPLINE();
-       val = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+               /* Behave like FETCH_OBJ_W */
+               zend_free_op free_op1, free_op2;
+               zval *property;
 
-       if (IS_TMP_VAR == IS_TMP_VAR) {
-               if (Z_TYPE_P(val) == IS_TRUE) {
-                       ZVAL_TRUE(EX_VAR(opline->result.var));
-                       ZEND_VM_SET_OPCODE(opline + 1);
-                       ZEND_VM_CONTINUE();
-               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
-                       ZVAL_FALSE(EX_VAR(opline->result.var));
-                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
-                       ZEND_VM_CONTINUE();
+               SAVE_OPLINE();
+               property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+               container = NULL;
+
+        if (IS_CONST == IS_CONST || IS_CONST == IS_TMP_VAR) {
+            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+        }
+               if (IS_CONST == IS_VAR && UNEXPECTED(container == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+               }
+               zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CONST, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+               zval_ptr_dtor_nogc(free_op2);
+               if (IS_CONST == IS_VAR && READY_TO_DESTROY(free_op1)) {
+                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
                }
-       }
 
-       if (i_zend_is_true(val TSRMLS_CC)) {
-               zval_ptr_dtor_nogc(free_op1);
-               ZVAL_TRUE(EX_VAR(opline->result.var));
-               opline++;
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
        } else {
-               zval_ptr_dtor_nogc(free_op1);
-               ZVAL_FALSE(EX_VAR(opline->result.var));
-               opline = opline->op2.jmp_addr;
+               return ZEND_FETCH_OBJ_R_SPEC_CONST_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
-       if (UNEXPECTED(EG(exception) != NULL)) {
-               HANDLE_EXCEPTION();
-       }
-       ZEND_VM_JMP(opline);
 }
 
-static int ZEND_FASTCALL  ZEND_JMPNZ_EX_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
-       zval *val;
+       zval *function_name;
+       zend_class_entry *ce;
+       zend_object *object;
+       zend_function *fbc;
 
        SAVE_OPLINE();
-       val = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
 
-       if (IS_TMP_VAR == IS_TMP_VAR) {
-               if (Z_TYPE_P(val) == IS_TRUE) {
-                       ZVAL_TRUE(EX_VAR(opline->result.var));
-                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
-                       ZEND_VM_CONTINUE();
-               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
-                       ZVAL_FALSE(EX_VAR(opline->result.var));
-                       ZEND_VM_SET_OPCODE(opline + 1);
-                       ZEND_VM_CONTINUE();
+       if (IS_CONST == IS_CONST) {
+               /* no function found. try a static method in class */
+               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv))) {
+                       ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv));
+               } else {
+                       ce = zend_fetch_class_by_name(Z_STR_P(opline->op1.zv), opline->op1.zv + 1, ZEND_FETCH_CLASS_DEFAULT TSRMLS_CC);
+                       if (UNEXPECTED(EG(exception) != NULL)) {
+                               HANDLE_EXCEPTION();
+                       }
+                       if (UNEXPECTED(ce == NULL)) {
+                               zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
+                       }
+                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op1.zv), ce);
                }
-       }
-       if (i_zend_is_true(val TSRMLS_CC)) {
-               ZVAL_TRUE(EX_VAR(opline->result.var));
-               opline = opline->op2.jmp_addr;
        } else {
-               ZVAL_FALSE(EX_VAR(opline->result.var));
-               opline++;
-       }
-       zval_ptr_dtor_nogc(free_op1);
-       if (UNEXPECTED(EG(exception) != NULL)) {
-               HANDLE_EXCEPTION();
+               ce = Z_CE_P(EX_VAR(opline->op1.var));
        }
-       ZEND_VM_JMP(opline);
-}
-
-static int ZEND_FASTCALL  ZEND_RETURN_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *retval_ptr;
-       zend_free_op free_op1;
 
-       SAVE_OPLINE();
-       retval_ptr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+       if (IS_CONST == IS_CONST &&
+           (IS_TMP_VAR|IS_VAR) == IS_CONST &&
+           CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+               fbc = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+       } else if (IS_CONST != IS_CONST &&
+                  (IS_TMP_VAR|IS_VAR) == IS_CONST &&
+                  (fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce))) {
+               /* do nothing */
+       } else if ((IS_TMP_VAR|IS_VAR) != IS_UNUSED) {
+               zend_free_op free_op2;
 
-       if (!EX(return_value)) {
-               zval_ptr_dtor_nogc(free_op1);
-       } else {
-               if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
-                       ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
-                       if (IS_TMP_VAR == IS_CONST) {
-                               if (UNEXPECTED(Z_OPT_COPYABLE_P(EX(return_value)))) {
-                                       zval_copy_ctor_func(EX(return_value));
+               function_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+               if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+                       if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
+                               if (UNEXPECTED(EG(exception) != NULL)) {
+                                       HANDLE_EXCEPTION();
                                }
-                       }
-               } else if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) && Z_ISREF_P(retval_ptr)) {
-                       ZVAL_COPY(EX(return_value), Z_REFVAL_P(retval_ptr));
+                               zend_error_noreturn(E_ERROR, "Function name must be a string");
+                       }
+               }
 
+               if (ce->get_static_method) {
+                       fbc = ce->get_static_method(ce, Z_STR_P(function_name) TSRMLS_CC);
                } else {
-                       ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
-                       if (IS_TMP_VAR == IS_CV) {
-                               if (Z_OPT_REFCOUNTED_P(retval_ptr)) Z_ADDREF_P(retval_ptr);
-                       }
+                       fbc = zend_std_get_static_method(ce, Z_STR_P(function_name), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
                }
-       }
-       return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_RETURN_BY_REF_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *retval_ptr;
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-
-       do {
-               if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR ||
-                   (IS_TMP_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_VALUE)) {
-                       /* Not supposed to happen, but we'll allow it */
-                       zend_error(E_NOTICE, "Only variable references should be returned by reference");
-
-                       retval_ptr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-                       if (!EX(return_value)) {
-                               if (IS_TMP_VAR == IS_TMP_VAR) {
-                                       zval_ptr_dtor_nogc(free_op1);
-                               }
+               if (UNEXPECTED(fbc == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name->val, Z_STRVAL_P(function_name));
+               }
+               if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
+                   EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
+                   EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0)) {
+                       if (IS_CONST == IS_CONST) {
+                               CACHE_PTR(Z_CACHE_SLOT_P(function_name), fbc);
                        } else {
-                               ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
-                               Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
-                               if (IS_TMP_VAR != IS_TMP_VAR) {
-                                       zval_opt_copy_ctor_no_imm(EX(return_value));
-                               }
+                               CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), ce, fbc);
                        }
-                       break;
-               }
-
-               retval_ptr = NULL;
-
-               if (IS_TMP_VAR == IS_VAR && UNEXPECTED(retval_ptr == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot return string offsets by reference");
                }
-
-               if (IS_TMP_VAR == IS_VAR) {
-                       if (retval_ptr == &EG(uninitialized_zval) ||
-                           (opline->extended_value == ZEND_RETURNS_FUNCTION &&
-                            !(Z_VAR_FLAGS_P(retval_ptr) & IS_VAR_RET_REF))) {
-                               zend_error(E_NOTICE, "Only variable references should be returned by reference");
-                               if (EX(return_value)) {
-                                       ZVAL_NEW_REF(EX(return_value), retval_ptr);
-                                       Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
-                                       if (Z_REFCOUNTED_P(retval_ptr)) Z_ADDREF_P(retval_ptr);
-                               }
-                               break;
-                       }
+               if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+                       zval_ptr_dtor_nogc(free_op2);
                }
-
-               if (EX(return_value)) {
-                       ZVAL_MAKE_REF(retval_ptr);
-                       Z_ADDREF_P(retval_ptr);
-                       ZVAL_REF(EX(return_value), Z_REF_P(retval_ptr));
-                       Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
+       } else {
+               if (UNEXPECTED(ce->constructor == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot call constructor");
                }
-       } while (0);
-
-       return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_THROW_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *value;
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-       value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_TMP_VAR == IS_CONST || UNEXPECTED(Z_TYPE_P(value) != IS_OBJECT)) {
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       HANDLE_EXCEPTION();
+               if (Z_OBJ(EX(This)) && Z_OBJ(EX(This))->ce != ce->constructor->common.scope && (ce->constructor->common.fn_flags & ZEND_ACC_PRIVATE)) {
+                       zend_error_noreturn(E_ERROR, "Cannot call private %s::__construct()", ce->name->val);
                }
-               zend_error_noreturn(E_ERROR, "Can only throw objects");
+               fbc = ce->constructor;
        }
 
-       zend_exception_save(TSRMLS_C);
-       if (IS_TMP_VAR != IS_TMP_VAR) {
-               if (Z_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+       object = NULL;
+       if (!(fbc->common.fn_flags & ZEND_ACC_STATIC)) {
+               if (Z_OBJ(EX(This))) {
+                       object = Z_OBJ(EX(This));
+                       GC_REFCOUNT(object)++;
+               }
+               if (!object ||
+                   !instanceof_function(object->ce, ce TSRMLS_CC)) {
+                   /* We are calling method of the other (incompatible) class,
+                      but passing $this. This is done for compatibility with php-4. */
+                       if (fbc->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
+                               zend_error(
+                                       object ? E_DEPRECATED : E_STRICT,
+                                       "Non-static method %s::%s() should not be called statically%s",
+                                       fbc->common.scope->name->val, fbc->common.function_name->val,
+                                       object ? ", assuming $this from incompatible context" : "");
+                       } else {
+                               /* An internal function assumes $this is present and won't check that. So PHP would crash by allowing the call. */
+                               zend_error_noreturn(
+                                       E_ERROR,
+                                       "Non-static method %s::%s() cannot be called statically%s",
+                                       fbc->common.scope->name->val, fbc->common.function_name->val,
+                                       object ? ", assuming $this from incompatible context" : "");
+                       }
+               }
        }
 
-       zend_throw_exception_object(value TSRMLS_CC);
-       zend_exception_restore(TSRMLS_C);
-
-       HANDLE_EXCEPTION();
-}
-
-static int ZEND_FASTCALL  ZEND_SEND_VAL_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *value, *arg;
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-       value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-       arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
-       ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
-       ZVAL_COPY_VALUE(arg, value);
-       if (IS_TMP_VAR == IS_CONST) {
-               if (UNEXPECTED(Z_OPT_COPYABLE_P(arg))) {
-                       zval_copy_ctor_func(arg);
+       if (IS_CONST != IS_CONST) {
+               /* previous opcode is ZEND_FETCH_CLASS */
+               if ((opline-1)->extended_value == ZEND_FETCH_CLASS_PARENT || (opline-1)->extended_value == ZEND_FETCH_CLASS_SELF) {
+                       ce = EX(called_scope);
                }
        }
-       ZEND_VM_NEXT_OPCODE();
-}
 
-static int ZEND_FASTCALL  ZEND_SEND_VAL_EX_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *value, *arg;
-       zend_free_op free_op1;
+       EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
+               fbc, opline->extended_value, ce, object, EX(call) TSRMLS_CC);
 
-       SAVE_OPLINE();
-       if (ARG_MUST_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
-               zend_error_noreturn(E_ERROR, "Cannot pass parameter %d by reference", opline->op2.num);
-       }
-       value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-       arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
-       ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
-       ZVAL_COPY_VALUE(arg, value);
-       if (IS_TMP_VAR == IS_CONST) {
-               if (UNEXPECTED(Z_OPT_COPYABLE_P(arg))) {
-                       zval_copy_ctor_func(arg);
-               }
+       if ((IS_TMP_VAR|IS_VAR) == IS_UNUSED) {
+               EX(call)->return_value = NULL;
        }
+
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_BOOL_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_CASE_SPEC_CONST_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
-       zval *retval = EX_VAR(opline->result.var);
+       zend_free_op free_op2;
+       zval *result = EX_VAR(opline->result.var);
 
        SAVE_OPLINE();
-       /* PHP 3.0 returned "" for false and 1 for true, here we use 0 and 1 for now */
-       ZVAL_BOOL(retval, i_zend_is_true(_get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1) TSRMLS_CC));
-       zval_ptr_dtor_nogc(free_op1);
+       fast_equal_function(result,
+                opline->op1.zv,
+                _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
 
+       zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_CLONE_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
-       zval *obj;
-       zend_class_entry *ce;
-       zend_function *clone;
-       zend_object_clone_obj_t clone_call;
 
-       SAVE_OPLINE();
-       obj = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+       zval *expr_ptr, new_expr;
 
-       if (IS_TMP_VAR == IS_CONST ||
-           (IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(obj) != IS_OBJECT))) {
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       HANDLE_EXCEPTION();
+       SAVE_OPLINE();
+       if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) &&
+           (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
+               expr_ptr = NULL;
+               if (IS_CONST == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
                }
-               zend_error_noreturn(E_ERROR, "__clone method called on non-object");
-       }
+               ZVAL_MAKE_REF(expr_ptr);
+               Z_ADDREF_P(expr_ptr);
 
-       ce = Z_OBJCE_P(obj);
-       clone = ce ? ce->clone : NULL;
-       clone_call =  Z_OBJ_HT_P(obj)->clone_obj;
-       if (UNEXPECTED(clone_call == NULL)) {
-               if (ce) {
-                       zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object of class %s", ce->name->val);
-               } else {
-                       zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object");
+       } else {
+               expr_ptr = opline->op1.zv;
+               if (IS_CONST == IS_TMP_VAR) {
+                       ZVAL_COPY_VALUE(&new_expr, expr_ptr);
+                       expr_ptr = &new_expr;
+               } else if (IS_CONST == IS_CONST) {
+                       if (!Z_IMMUTABLE_P(expr_ptr)) {
+                               ZVAL_DUP(&new_expr, expr_ptr);
+                               expr_ptr = &new_expr;
+                       }
+               } else if ((IS_CONST == IS_CV || IS_CONST == IS_VAR) && Z_ISREF_P(expr_ptr)) {
+                       expr_ptr = Z_REFVAL_P(expr_ptr);
+                       if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
+
+               } else if (IS_CONST == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
+                       Z_ADDREF_P(expr_ptr);
                }
        }
 
-       if (ce && clone) {
-               if (clone->op_array.fn_flags & ZEND_ACC_PRIVATE) {
-                       /* Ensure that if we're calling a private function, we're allowed to do so.
-                        */
-                       if (UNEXPECTED(ce != EG(scope))) {
-                               zend_error_noreturn(E_ERROR, "Call to private %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
-                       }
-               } else if ((clone->common.fn_flags & ZEND_ACC_PROTECTED)) {
-                       /* Ensure that if we're calling a protected function, we're allowed to do so.
-                        */
-                       if (UNEXPECTED(!zend_check_protected(zend_get_function_root_class(clone), EG(scope)))) {
-                               zend_error_noreturn(E_ERROR, "Call to protected %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
-                       }
+       if ((IS_TMP_VAR|IS_VAR) != IS_UNUSED) {
+               zend_free_op free_op2;
+               zval *offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+               zend_string *str;
+               zend_ulong hval;
+
+add_again:
+               switch (Z_TYPE_P(offset)) {
+                       case IS_DOUBLE:
+                               hval = zend_dval_to_lval(Z_DVAL_P(offset));
+                               goto num_index;
+                       case IS_LONG:
+                               hval = Z_LVAL_P(offset);
+num_index:
+                               zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
+                               break;
+                       case IS_STRING:
+                               str = Z_STR_P(offset);
+                               if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+                                       if (ZEND_HANDLE_NUMERIC(str, hval)) {
+                                               goto num_index;
+                                       }
+                               }
+str_index:
+                               zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
+                               break;
+                       case IS_NULL:
+                               str = STR_EMPTY_ALLOC();
+                               goto str_index;
+                       case IS_FALSE:
+                               hval = 0;
+                               goto num_index;
+                       case IS_TRUE:
+                               hval = 1;
+                               goto num_index;
+                       case IS_REFERENCE:
+                               offset = Z_REFVAL_P(offset);
+                               goto add_again;
+                               break;
+                       default:
+                               zend_error(E_WARNING, "Illegal offset type");
+                               zval_ptr_dtor(expr_ptr);
+                               /* do nothing */
+                               break;
                }
+               zval_ptr_dtor_nogc(free_op2);
+       } else {
+               zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
        }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       if (EXPECTED(EG(exception) == NULL)) {
-               ZVAL_OBJ(EX_VAR(opline->result.var), clone_call(obj TSRMLS_CC));
-               if (!RETURN_VALUE_USED(opline) || UNEXPECTED(EG(exception) != NULL)) {
-                       OBJ_RELEASE(Z_OBJ_P(EX_VAR(opline->result.var)));
+static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CONST_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       zval *array;
+       uint32_t size;
+       USE_OPLINE
+
+       array = EX_VAR(opline->result.var);
+       if (IS_CONST != IS_UNUSED) {
+               size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
+       } else {
+               size = 0;
+       }
+       ZVAL_NEW_ARR(array);
+       zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
+
+       if (IS_CONST != IS_UNUSED) {
+               /* Explicitly initialize array as not-packed if flag is set */
+               if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
+                       zend_hash_real_init(Z_ARRVAL_P(array), 0);
                }
        }
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       if (IS_CONST == IS_UNUSED) {
+               ZEND_VM_NEXT_OPCODE();
+#if 0 || IS_CONST != IS_UNUSED
+       } else {
+               return ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+#endif
+       }
 }
 
-static int ZEND_FASTCALL  ZEND_CAST_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CONST_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
-       zval *expr;
-       zval *result = EX_VAR(opline->result.var);
+       zend_free_op free_op2;
+       zval *container;
+       int result;
+       zend_ulong hval;
+       zval *offset;
 
        SAVE_OPLINE();
-       expr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+       container = opline->op1.zv;
+       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       switch (opline->extended_value) {
-               case IS_NULL:
-                       /* This code is taken from convert_to_null. However, it does not seems very useful,
-                        * because a conversion to null always results in the same value. This could only
-                        * be relevant if a cast_object handler for IS_NULL has some kind of side-effect. */
-#if 0
-                       if (IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) {
-                               ZVAL_DEREF(expr);
+       if (IS_CONST != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
+               HashTable *ht = Z_ARRVAL_P(container);
+               zval *value;
+               zend_string *str;
+
+isset_again:
+               if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
+                       str = Z_STR_P(offset);
+                       if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+                               if (ZEND_HANDLE_NUMERIC(str, hval)) {
+                                       goto num_index_prop;
+                               }
                        }
-                       if (Z_TYPE_P(expr) == IS_OBJECT && Z_OBJ_HT_P(expr)->cast_object) {
-                               if (Z_OBJ_HT_P(expr)->cast_object(expr, result, IS_NULL TSRMLS_CC) == SUCCESS) {
+str_index_prop:
+                       value = zend_hash_find_ind(ht, str);
+               } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
+                       hval = Z_LVAL_P(offset);
+num_index_prop:
+                       value = zend_hash_index_find(ht, hval);
+               } else {
+                       switch (Z_TYPE_P(offset)) {
+                               case IS_DOUBLE:
+                                       hval = zend_dval_to_lval(Z_DVAL_P(offset));
+                                       goto num_index_prop;
+                               case IS_NULL:
+                                       str = STR_EMPTY_ALLOC();
+                                       goto str_index_prop;
+                               case IS_FALSE:
+                                       hval = 0;
+                                       goto num_index_prop;
+                               case IS_TRUE:
+                                       hval = 1;
+                                       goto num_index_prop;
+                               case IS_RESOURCE:
+                                       hval = Z_RES_HANDLE_P(offset);
+                                       goto num_index_prop;
+                               case IS_REFERENCE:
+                                       offset = Z_REFVAL_P(offset);
+                                       goto isset_again;
+                               default:
+                                       zend_error(E_WARNING, "Illegal offset type in isset or empty");
+                                       value = NULL;
                                        break;
-                               }
                        }
-#endif
+               }
 
-                       ZVAL_NULL(result);
-                       break;
-               case _IS_BOOL:
-                       ZVAL_BOOL(result, zend_is_true(expr TSRMLS_CC));
-                       break;
-               case IS_LONG:
-                       ZVAL_LONG(result, zval_get_long(expr));
-                       break;
-               case IS_DOUBLE:
-                       ZVAL_DOUBLE(result, zval_get_double(expr));
-                       break;
-               case IS_STRING:
-                       ZVAL_STR(result, zval_get_string(expr));
-                       break;
-               default:
-                       /* If value is already of correct type, return it directly */
-                       if (Z_TYPE_P(expr) == opline->extended_value) {
-                               ZVAL_COPY_VALUE(result, expr);
-                               if (IS_TMP_VAR == IS_CONST) {
-                                       if (UNEXPECTED(Z_OPT_COPYABLE_P(result))) {
-                                               zval_copy_ctor_func(result);
-                                       }
-                               } else if (IS_TMP_VAR != IS_TMP_VAR) {
-                                       if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
-                               }
+               if (opline->extended_value & ZEND_ISSET) {
+                       /* > IS_NULL means not IS_UNDEF and not IS_NULL */
+                       result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
+                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
+               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+                       result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
+               }
+       } else if (IS_CONST == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+               if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
+                       result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
+               } else {
+                       zend_error(E_NOTICE, "Trying to check element of non-array");
+                       result = 0;
+               }
+               if ((opline->extended_value & ZEND_ISSET) == 0) {
+                       result = !result;
+               }
+       } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
+               zval tmp;
 
-                               CHECK_EXCEPTION();
-                               ZEND_VM_NEXT_OPCODE();
+               result = 0;
+               if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
+                       if ((IS_TMP_VAR|IS_VAR) & (IS_CV|IS_VAR)) {
+                               ZVAL_DEREF(offset);
                        }
-
-                       if (opline->extended_value == IS_ARRAY) {
-                               if (Z_TYPE_P(expr) != IS_OBJECT) {
-                                       ZVAL_NEW_ARR(result);
-                                       zend_hash_init(Z_ARRVAL_P(result), 8, NULL, ZVAL_PTR_DTOR, 0);
-                                       if (Z_TYPE_P(expr) != IS_NULL) {
-                                               expr = zend_hash_index_add_new(Z_ARRVAL_P(result), 0, expr);
-                                               if (IS_TMP_VAR == IS_CONST) {
-                                                       if (UNEXPECTED(Z_OPT_COPYABLE_P(expr))) {
-                                                               zval_copy_ctor_func(expr);
-                                                       }
-                                               } else {
-                                                       if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
-                                               }
-                                       }
-                               } else {
-                                       ZVAL_COPY_VALUE(result, expr);
-                                       Z_ADDREF_P(result);
-                                       convert_to_array(result);
-                               }
-                       } else {
-                               if (Z_TYPE_P(expr) != IS_ARRAY) {
-                                       object_init(result);
-                                       if (Z_TYPE_P(expr) != IS_NULL) {
-                                               expr = zend_hash_str_add_new(Z_OBJPROP_P(result), "scalar", sizeof("scalar")-1, expr);
-                                               if (IS_TMP_VAR == IS_CONST) {
-                                                       if (UNEXPECTED(Z_OPT_COPYABLE_P(expr))) {
-                                                               zval_copy_ctor_func(expr);
-                                                       }
-                                               } else {
-                                                       if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
-                                               }
-                                       }
-                               } else {
-                                       ZVAL_COPY_VALUE(result, expr);
-                                       zval_opt_copy_ctor(result);
-                                       convert_to_object(result);
+                       if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
+                                       || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
+                                               && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
+                               ZVAL_DUP(&tmp, offset);
+                               convert_to_long(&tmp);
+                               offset = &tmp;
+                       }
+               }
+               if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
+                       if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
+                               if ((opline->extended_value & ZEND_ISSET) ||
+                                   Z_STRVAL_P(container)[offset->value.lval] != '0') {
+                                       result = 1;
                                }
                        }
+               }
+               if ((opline->extended_value & ZEND_ISSET) == 0) {
+                       result = !result;
+               }
+       } else {
+               result = ((opline->extended_value & ZEND_ISSET) == 0);
        }
 
-       zval_ptr_dtor_nogc(free_op1);
+       zval_ptr_dtor_nogc(free_op2);
+       ZVAL_BOOL(EX_VAR(opline->result.var), result);
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INCLUDE_OR_EVAL_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CONST_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_op_array *new_op_array=NULL;
-       zend_free_op free_op1;
-       zval *inc_filename;
-       zval tmp_inc_filename;
-       zend_bool failure_retval=0;
+       zend_free_op free_op2;
+       zval *container;
+       int result;
+       zval *offset;
 
        SAVE_OPLINE();
-       inc_filename = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
-       ZVAL_UNDEF(&tmp_inc_filename);
-       if (Z_TYPE_P(inc_filename) != IS_STRING) {
-               ZVAL_STR(&tmp_inc_filename, zval_get_string(inc_filename));
-               inc_filename = &tmp_inc_filename;
-       }
+       container = opline->op1.zv;
+       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if (opline->extended_value != ZEND_EVAL && strlen(Z_STRVAL_P(inc_filename)) != Z_STRLEN_P(inc_filename)) {
-               if (opline->extended_value == ZEND_INCLUDE_ONCE || opline->extended_value == ZEND_INCLUDE) {
-                       zend_message_dispatcher(ZMSG_FAILED_INCLUDE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
+       if (IS_CONST == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+               if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
+                       result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
                } else {
-                       zend_message_dispatcher(ZMSG_FAILED_REQUIRE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
+                       zend_error(E_NOTICE, "Trying to check property of non-object");
+                       result = 0;
+               }
+               if ((opline->extended_value & ZEND_ISSET) == 0) {
+                       result = !result;
                }
        } else {
-               switch (opline->extended_value) {
-                       case ZEND_INCLUDE_ONCE:
-                       case ZEND_REQUIRE_ONCE: {
-                                       zend_file_handle file_handle;
-                                       char *resolved_path;
+               result = ((opline->extended_value & ZEND_ISSET) == 0);
+       }
 
-                                       resolved_path = zend_resolve_path(Z_STRVAL_P(inc_filename), (int)Z_STRLEN_P(inc_filename) TSRMLS_CC);
-                                       if (resolved_path) {
-                                               failure_retval = zend_hash_str_exists(&EG(included_files), resolved_path, (int)strlen(resolved_path));
-                                       } else {
-                                               resolved_path = Z_STRVAL_P(inc_filename);
-                                       }
+       zval_ptr_dtor_nogc(free_op2);
+       ZVAL_BOOL(EX_VAR(opline->result.var), result);
 
-                                       if (failure_retval) {
-                                               /* do nothing, file already included */
-                                       } else if (SUCCESS == zend_stream_open(resolved_path, &file_handle TSRMLS_CC)) {
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-                                               if (!file_handle.opened_path) {
-                                                       file_handle.opened_path = estrdup(resolved_path);
-                                               }
+static int ZEND_FASTCALL  ZEND_BW_NOT_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
 
-                                               if (zend_hash_str_add_empty_element(&EG(included_files), file_handle.opened_path, (int)strlen(file_handle.opened_path))) {
-                                                       new_op_array = zend_compile_file(&file_handle, (opline->extended_value==ZEND_INCLUDE_ONCE?ZEND_INCLUDE:ZEND_REQUIRE) TSRMLS_CC);
-                                                       zend_destroy_file_handle(&file_handle TSRMLS_CC);
-                                               } else {
-                                                       zend_file_handle_dtor(&file_handle TSRMLS_CC);
-                                                       failure_retval=1;
-                                               }
-                                       } else {
-                                               if (opline->extended_value == ZEND_INCLUDE_ONCE) {
-                                                       zend_message_dispatcher(ZMSG_FAILED_INCLUDE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
-                                               } else {
-                                                       zend_message_dispatcher(ZMSG_FAILED_REQUIRE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
-                                               }
-                                       }
-                                       if (resolved_path != Z_STRVAL_P(inc_filename)) {
-                                               efree(resolved_path);
-                                       }
-                               }
-                               break;
-                       case ZEND_INCLUDE:
-                       case ZEND_REQUIRE:
-                               new_op_array = compile_filename(opline->extended_value, inc_filename TSRMLS_CC);
-                               break;
-                       case ZEND_EVAL: {
-                                       char *eval_desc = zend_make_compiled_string_description("eval()'d code" TSRMLS_CC);
+       SAVE_OPLINE();
+       bitwise_not_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1) TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-                                       new_op_array = zend_compile_string(inc_filename, eval_desc TSRMLS_CC);
-                                       efree(eval_desc);
-                               }
-                               break;
-                       EMPTY_SWITCH_DEFAULT_CASE()
-               }
-       }
-       if (Z_TYPE(tmp_inc_filename) != IS_UNDEF) {
-               zend_string_release(Z_STR(tmp_inc_filename));
-       }
+static int ZEND_FASTCALL  ZEND_BOOL_NOT_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+
+       SAVE_OPLINE();
+       boolean_not_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
-       if (UNEXPECTED(EG(exception) != NULL)) {
-               HANDLE_EXCEPTION();
-       } else if (EXPECTED(new_op_array != NULL)) {
-               zval *return_value = NULL;
-               zend_execute_data *call;
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-               if (RETURN_VALUE_USED(opline)) {
-                       return_value = EX_VAR(opline->result.var);
-               }
+static int ZEND_FASTCALL  ZEND_ECHO_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *z;
 
-               new_op_array->scope = EG(scope); /* ??? */
+       SAVE_OPLINE();
+       z = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
 
-               call = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_CODE,
-                       (zend_function*)new_op_array, 0, EX(called_scope), Z_OBJ(EX(This)), NULL TSRMLS_CC);
+       zend_print_variable(z TSRMLS_CC);
 
-               if (EX(symbol_table)) {
-                       call->symbol_table = EX(symbol_table);
-               } else {
-                       call->symbol_table = zend_rebuild_symbol_table(TSRMLS_C);
-               }
+       zval_ptr_dtor_nogc(free_op1);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-               call->prev_execute_data = execute_data;
-           i_init_code_execute_data(call, new_op_array, return_value TSRMLS_CC);
-               if (EXPECTED(zend_execute_ex == execute_ex)) {
-                       ZEND_VM_ENTER();
-               } else {
-                       ZEND_ADD_CALL_FLAG(call, ZEND_CALL_TOP);
-                       zend_execute_ex(call TSRMLS_CC);
-               }
+static int ZEND_FASTCALL  ZEND_PRINT_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-               destroy_op_array(new_op_array TSRMLS_CC);
-               efree_size(new_op_array, sizeof(zend_op_array));
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       zend_throw_exception_internal(NULL TSRMLS_CC);
-                       HANDLE_EXCEPTION();
+       ZVAL_LONG(EX_VAR(opline->result.var), 1);
+       return ZEND_ECHO_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL  ZEND_JMPZ_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *val;
+
+       SAVE_OPLINE();
+       val = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+
+       if (IS_TMP_VAR == IS_TMP_VAR) {
+               if (Z_TYPE_P(val) == IS_TRUE) {
+                       ZEND_VM_SET_OPCODE(opline + 1);
+                       ZEND_VM_CONTINUE();
+               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+                       ZEND_VM_CONTINUE();
                }
+       }
 
-       } else if (RETURN_VALUE_USED(opline)) {
-               ZVAL_BOOL(EX_VAR(opline->result.var), failure_retval);
+       if (i_zend_is_true(val TSRMLS_CC)) {
+               opline++;
+       } else {
+               opline = opline->op2.jmp_addr;
        }
-       ZEND_VM_NEXT_OPCODE();
+       zval_ptr_dtor_nogc(free_op1);
+       if (UNEXPECTED(EG(exception) != NULL)) {
+               HANDLE_EXCEPTION();
+       }
+       ZEND_VM_JMP(opline);
 }
 
-static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_JMPNZ_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
-       zval *array_ptr, *array_ref, iterator, tmp;
-       HashTable *fe_ht;
-       zend_object_iterator *iter = NULL;
-       zend_class_entry *ce = NULL;
-       zend_bool is_empty = 0;
+       zval *val;
 
        SAVE_OPLINE();
+       val = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
 
-       if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) &&
-           (opline->extended_value & ZEND_FE_FETCH_BYREF)) {
-               array_ptr = array_ref = NULL;
-               ZVAL_DEREF(array_ptr);
-               if (Z_TYPE_P(array_ptr) == IS_ARRAY) {
-                       SEPARATE_ARRAY(array_ptr);
-                       if (!Z_ISREF_P(array_ref)) {
-                               ZVAL_NEW_REF(array_ref, array_ref);
-                               array_ptr = Z_REFVAL_P(array_ref);
-                       }
-                       if (Z_REFCOUNTED_P(array_ref)) Z_ADDREF_P(array_ref);
-               } else if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
-                       ce = Z_OBJCE_P(array_ptr);
-                       if (ce->get_iterator == NULL) {
-                               Z_ADDREF_P(array_ptr);
-                       }
-                       array_ref = array_ptr;
-               } else {
-                       if (Z_REFCOUNTED_P(array_ref)) Z_ADDREF_P(array_ref);
+       if (IS_TMP_VAR == IS_TMP_VAR) {
+               if (Z_TYPE_P(val) == IS_TRUE) {
+                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+                       ZEND_VM_CONTINUE();
+               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+                       ZEND_VM_SET_OPCODE(opline + 1);
+                       ZEND_VM_CONTINUE();
+               }
+       }
+
+       if (i_zend_is_true(val TSRMLS_CC)) {
+               opline = opline->op2.jmp_addr;
+       } else {
+               opline++;
+       }
+       zval_ptr_dtor_nogc(free_op1);
+       if (UNEXPECTED(EG(exception) != NULL)) {
+               HANDLE_EXCEPTION();
+       }
+       ZEND_VM_JMP(opline);
+}
+
+static int ZEND_FASTCALL  ZEND_JMPZNZ_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *val;
+
+       SAVE_OPLINE();
+       val = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+
+       if (IS_TMP_VAR == IS_TMP_VAR) {
+               if (EXPECTED(Z_TYPE_P(val) == IS_TRUE)) {
+                       ZEND_VM_SET_RELATIVE_OPCODE(opline, opline->extended_value);
+                       ZEND_VM_CONTINUE();
+               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+                       ZEND_VM_CONTINUE();
+               }
+       }
+
+       if (i_zend_is_true(val TSRMLS_CC)) {
+               opline = (zend_op*)(((char*)opline) + opline->extended_value);
+       } else {
+               opline = opline->op2.jmp_addr;
+       }
+       zval_ptr_dtor_nogc(free_op1);
+       if (UNEXPECTED(EG(exception) != NULL)) {
+               HANDLE_EXCEPTION();
+       }
+       ZEND_VM_JMP(opline);
+}
+
+static int ZEND_FASTCALL  ZEND_JMPZ_EX_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *val;
+
+       SAVE_OPLINE();
+       val = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+
+       if (IS_TMP_VAR == IS_TMP_VAR) {
+               if (Z_TYPE_P(val) == IS_TRUE) {
+                       ZVAL_TRUE(EX_VAR(opline->result.var));
+                       ZEND_VM_SET_OPCODE(opline + 1);
+                       ZEND_VM_CONTINUE();
+               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+                       ZVAL_FALSE(EX_VAR(opline->result.var));
+                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+                       ZEND_VM_CONTINUE();
+               }
+       }
+
+       if (i_zend_is_true(val TSRMLS_CC)) {
+               zval_ptr_dtor_nogc(free_op1);
+               ZVAL_TRUE(EX_VAR(opline->result.var));
+               opline++;
+       } else {
+               zval_ptr_dtor_nogc(free_op1);
+               ZVAL_FALSE(EX_VAR(opline->result.var));
+               opline = opline->op2.jmp_addr;
+       }
+       if (UNEXPECTED(EG(exception) != NULL)) {
+               HANDLE_EXCEPTION();
+       }
+       ZEND_VM_JMP(opline);
+}
+
+static int ZEND_FASTCALL  ZEND_JMPNZ_EX_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *val;
+
+       SAVE_OPLINE();
+       val = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+
+       if (IS_TMP_VAR == IS_TMP_VAR) {
+               if (Z_TYPE_P(val) == IS_TRUE) {
+                       ZVAL_TRUE(EX_VAR(opline->result.var));
+                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+                       ZEND_VM_CONTINUE();
+               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+                       ZVAL_FALSE(EX_VAR(opline->result.var));
+                       ZEND_VM_SET_OPCODE(opline + 1);
+                       ZEND_VM_CONTINUE();
+               }
+       }
+       if (i_zend_is_true(val TSRMLS_CC)) {
+               ZVAL_TRUE(EX_VAR(opline->result.var));
+               opline = opline->op2.jmp_addr;
+       } else {
+               ZVAL_FALSE(EX_VAR(opline->result.var));
+               opline++;
+       }
+       zval_ptr_dtor_nogc(free_op1);
+       if (UNEXPECTED(EG(exception) != NULL)) {
+               HANDLE_EXCEPTION();
+       }
+       ZEND_VM_JMP(opline);
+}
+
+static int ZEND_FASTCALL  ZEND_RETURN_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zval *retval_ptr;
+       zend_free_op free_op1;
+
+       SAVE_OPLINE();
+       retval_ptr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+
+       if (!EX(return_value)) {
+               zval_ptr_dtor_nogc(free_op1);
+       } else {
+               if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
+                       ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
+                       if (IS_TMP_VAR == IS_CONST) {
+                               if (UNEXPECTED(Z_OPT_COPYABLE_P(EX(return_value)))) {
+                                       zval_copy_ctor_func(EX(return_value));
+                               }
+                       }
+               } else if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) && Z_ISREF_P(retval_ptr)) {
+                       ZVAL_COPY(EX(return_value), Z_REFVAL_P(retval_ptr));
+
+               } else {
+                       ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
+                       if (IS_TMP_VAR == IS_CV) {
+                               if (Z_OPT_REFCOUNTED_P(retval_ptr)) Z_ADDREF_P(retval_ptr);
+                       }
+               }
+       }
+       return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL  ZEND_RETURN_BY_REF_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zval *retval_ptr;
+       zend_free_op free_op1;
+
+       SAVE_OPLINE();
+
+       do {
+               if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR ||
+                   (IS_TMP_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_VALUE)) {
+                       /* Not supposed to happen, but we'll allow it */
+                       zend_error(E_NOTICE, "Only variable references should be returned by reference");
+
+                       retval_ptr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+                       if (!EX(return_value)) {
+                               if (IS_TMP_VAR == IS_TMP_VAR) {
+                                       zval_ptr_dtor_nogc(free_op1);
+                               }
+                       } else {
+                               ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
+                               Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
+                               if (IS_TMP_VAR != IS_TMP_VAR) {
+                                       zval_opt_copy_ctor_no_imm(EX(return_value));
+                               }
+                       }
+                       break;
+               }
+
+               retval_ptr = NULL;
+
+               if (IS_TMP_VAR == IS_VAR && UNEXPECTED(retval_ptr == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot return string offsets by reference");
+               }
+
+               if (IS_TMP_VAR == IS_VAR) {
+                       if (retval_ptr == &EG(uninitialized_zval) ||
+                           (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+                            !(Z_VAR_FLAGS_P(retval_ptr) & IS_VAR_RET_REF))) {
+                               zend_error(E_NOTICE, "Only variable references should be returned by reference");
+                               if (EX(return_value)) {
+                                       ZVAL_NEW_REF(EX(return_value), retval_ptr);
+                                       Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
+                                       if (Z_REFCOUNTED_P(retval_ptr)) Z_ADDREF_P(retval_ptr);
+                               }
+                               break;
+                       }
+               }
+
+               if (EX(return_value)) {
+                       ZVAL_MAKE_REF(retval_ptr);
+                       Z_ADDREF_P(retval_ptr);
+                       ZVAL_REF(EX(return_value), Z_REF_P(retval_ptr));
+                       Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
+               }
+       } while (0);
+
+       return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL  ZEND_THROW_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zval *value;
+       zend_free_op free_op1;
+
+       SAVE_OPLINE();
+       value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+
+       if (IS_TMP_VAR == IS_CONST || UNEXPECTED(Z_TYPE_P(value) != IS_OBJECT)) {
+               if (UNEXPECTED(EG(exception) != NULL)) {
+                       HANDLE_EXCEPTION();
+               }
+               zend_error_noreturn(E_ERROR, "Can only throw objects");
+       }
+
+       zend_exception_save(TSRMLS_C);
+       if (IS_TMP_VAR != IS_TMP_VAR) {
+               if (Z_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+       }
+
+       zend_throw_exception_object(value TSRMLS_CC);
+       zend_exception_restore(TSRMLS_C);
+
+       HANDLE_EXCEPTION();
+}
+
+static int ZEND_FASTCALL  ZEND_SEND_VAL_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zval *value, *arg;
+       zend_free_op free_op1;
+
+       SAVE_OPLINE();
+       value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+       arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
+       ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
+       ZVAL_COPY_VALUE(arg, value);
+       if (IS_TMP_VAR == IS_CONST) {
+               if (UNEXPECTED(Z_OPT_COPYABLE_P(arg))) {
+                       zval_copy_ctor_func(arg);
+               }
+       }
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_SEND_VAL_EX_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zval *value, *arg;
+       zend_free_op free_op1;
+
+       SAVE_OPLINE();
+       if (ARG_MUST_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
+               zend_error_noreturn(E_ERROR, "Cannot pass parameter %d by reference", opline->op2.num);
+       }
+       value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+       arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
+       ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
+       ZVAL_COPY_VALUE(arg, value);
+       if (IS_TMP_VAR == IS_CONST) {
+               if (UNEXPECTED(Z_OPT_COPYABLE_P(arg))) {
+                       zval_copy_ctor_func(arg);
+               }
+       }
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_CLONE_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *obj;
+       zend_class_entry *ce;
+       zend_function *clone;
+       zend_object_clone_obj_t clone_call;
+
+       SAVE_OPLINE();
+       obj = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+
+       if (IS_TMP_VAR == IS_CONST ||
+           (IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(obj) != IS_OBJECT))) {
+               if (UNEXPECTED(EG(exception) != NULL)) {
+                       HANDLE_EXCEPTION();
+               }
+               zend_error_noreturn(E_ERROR, "__clone method called on non-object");
+       }
+
+       ce = Z_OBJCE_P(obj);
+       clone = ce ? ce->clone : NULL;
+       clone_call =  Z_OBJ_HT_P(obj)->clone_obj;
+       if (UNEXPECTED(clone_call == NULL)) {
+               if (ce) {
+                       zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object of class %s", ce->name->val);
+               } else {
+                       zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object");
+               }
+       }
+
+       if (ce && clone) {
+               if (clone->op_array.fn_flags & ZEND_ACC_PRIVATE) {
+                       /* Ensure that if we're calling a private function, we're allowed to do so.
+                        */
+                       if (UNEXPECTED(ce != EG(scope))) {
+                               zend_error_noreturn(E_ERROR, "Call to private %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
+                       }
+               } else if ((clone->common.fn_flags & ZEND_ACC_PROTECTED)) {
+                       /* Ensure that if we're calling a protected function, we're allowed to do so.
+                        */
+                       if (UNEXPECTED(!zend_check_protected(zend_get_function_root_class(clone), EG(scope)))) {
+                               zend_error_noreturn(E_ERROR, "Call to protected %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
+                       }
+               }
+       }
+
+       if (EXPECTED(EG(exception) == NULL)) {
+               ZVAL_OBJ(EX_VAR(opline->result.var), clone_call(obj TSRMLS_CC));
+               if (!RETURN_VALUE_USED(opline) || UNEXPECTED(EG(exception) != NULL)) {
+                       OBJ_RELEASE(Z_OBJ_P(EX_VAR(opline->result.var)));
+               }
+       }
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_CAST_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *expr;
+       zval *result = EX_VAR(opline->result.var);
+
+       SAVE_OPLINE();
+       expr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+
+       switch (opline->extended_value) {
+               case IS_NULL:
+                       /* This code is taken from convert_to_null. However, it does not seems very useful,
+                        * because a conversion to null always results in the same value. This could only
+                        * be relevant if a cast_object handler for IS_NULL has some kind of side-effect. */
+#if 0
+                       if (IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) {
+                               ZVAL_DEREF(expr);
+                       }
+                       if (Z_TYPE_P(expr) == IS_OBJECT && Z_OBJ_HT_P(expr)->cast_object) {
+                               if (Z_OBJ_HT_P(expr)->cast_object(expr, result, IS_NULL TSRMLS_CC) == SUCCESS) {
+                                       break;
+                               }
+                       }
+#endif
+
+                       ZVAL_NULL(result);
+                       break;
+               case _IS_BOOL:
+                       ZVAL_BOOL(result, zend_is_true(expr TSRMLS_CC));
+                       break;
+               case IS_LONG:
+                       ZVAL_LONG(result, zval_get_long(expr));
+                       break;
+               case IS_DOUBLE:
+                       ZVAL_DOUBLE(result, zval_get_double(expr));
+                       break;
+               case IS_STRING:
+                       ZVAL_STR(result, zval_get_string(expr));
+                       break;
+               default:
+                       /* If value is already of correct type, return it directly */
+                       if (Z_TYPE_P(expr) == opline->extended_value) {
+                               ZVAL_COPY_VALUE(result, expr);
+                               if (IS_TMP_VAR == IS_CONST) {
+                                       if (UNEXPECTED(Z_OPT_COPYABLE_P(result))) {
+                                               zval_copy_ctor_func(result);
+                                       }
+                               } else if (IS_TMP_VAR != IS_TMP_VAR) {
+                                       if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
+                               }
+
+                               CHECK_EXCEPTION();
+                               ZEND_VM_NEXT_OPCODE();
+                       }
+
+                       if (opline->extended_value == IS_ARRAY) {
+                               if (Z_TYPE_P(expr) != IS_OBJECT) {
+                                       ZVAL_NEW_ARR(result);
+                                       zend_hash_init(Z_ARRVAL_P(result), 8, NULL, ZVAL_PTR_DTOR, 0);
+                                       if (Z_TYPE_P(expr) != IS_NULL) {
+                                               expr = zend_hash_index_add_new(Z_ARRVAL_P(result), 0, expr);
+                                               if (IS_TMP_VAR == IS_CONST) {
+                                                       if (UNEXPECTED(Z_OPT_COPYABLE_P(expr))) {
+                                                               zval_copy_ctor_func(expr);
+                                                       }
+                                               } else {
+                                                       if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
+                                               }
+                                       }
+                               } else {
+                                       ZVAL_COPY_VALUE(result, expr);
+                                       Z_ADDREF_P(result);
+                                       convert_to_array(result);
+                               }
+                       } else {
+                               if (Z_TYPE_P(expr) != IS_ARRAY) {
+                                       object_init(result);
+                                       if (Z_TYPE_P(expr) != IS_NULL) {
+                                               expr = zend_hash_str_add_new(Z_OBJPROP_P(result), "scalar", sizeof("scalar")-1, expr);
+                                               if (IS_TMP_VAR == IS_CONST) {
+                                                       if (UNEXPECTED(Z_OPT_COPYABLE_P(expr))) {
+                                                               zval_copy_ctor_func(expr);
+                                                       }
+                                               } else {
+                                                       if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
+                                               }
+                                       }
+                               } else {
+                                       ZVAL_COPY_VALUE(result, expr);
+                                       zval_opt_copy_ctor(result);
+                                       convert_to_object(result);
+                               }
+                       }
+       }
+
+       zval_ptr_dtor_nogc(free_op1);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *array_ptr, *array_ref, iterator, tmp;
+       HashTable *fe_ht;
+       zend_object_iterator *iter = NULL;
+       zend_class_entry *ce = NULL;
+       zend_bool is_empty = 0;
+
+       SAVE_OPLINE();
+
+       if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) &&
+           (opline->extended_value & ZEND_FE_FETCH_BYREF)) {
+               array_ptr = array_ref = NULL;
+               ZVAL_DEREF(array_ptr);
+               if (Z_TYPE_P(array_ptr) == IS_ARRAY) {
+                       SEPARATE_ARRAY(array_ptr);
+                       if (!Z_ISREF_P(array_ref)) {
+                               ZVAL_NEW_REF(array_ref, array_ref);
+                               array_ptr = Z_REFVAL_P(array_ref);
+                       }
+                       if (Z_REFCOUNTED_P(array_ref)) Z_ADDREF_P(array_ref);
+               } else if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
+                       ce = Z_OBJCE_P(array_ptr);
+                       if (ce->get_iterator == NULL) {
+                               Z_ADDREF_P(array_ptr);
+                       }
+                       array_ref = array_ptr;
+               } else {
+                       if (Z_REFCOUNTED_P(array_ref)) Z_ADDREF_P(array_ref);
                }
        } else {
                array_ptr = array_ref = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
@@ -10450,174 +9761,26 @@ static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDL
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_TMP_CONST(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
-       zval *varname;
-       zval *retval;
-       zend_string *name;
-       HashTable *target_symbol_table;
+       zval *container;
 
        SAVE_OPLINE();
-       varname = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+       container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+       zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
 
-       if (IS_TMP_VAR == IS_CONST) {
-               name = Z_STR_P(varname);
-       } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
-               name = Z_STR_P(varname);
-               zend_string_addref(name);
-       } else {
-               name = zval_get_string(varname);
-       }
+       zval_ptr_dtor_nogc(free_op1);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       if (IS_CONST != IS_UNUSED) {
-               zend_class_entry *ce;
-
-               if (IS_CONST == IS_CONST) {
-                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                       } else {
-                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                               if (UNEXPECTED(ce == NULL)) {
-                                       if (IS_TMP_VAR != IS_CONST) {
-                                               zend_string_release(name);
-                                       }
-                                       zval_ptr_dtor_nogc(free_op1);
-                                       CHECK_EXCEPTION();
-                                       ZEND_VM_NEXT_OPCODE();
-                               }
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
-                       }
-               } else {
-                       ce = Z_CE_P(EX_VAR(opline->op2.var));
-               }
-               retval = zend_std_get_static_property(ce, name, 0, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op1);
-       } else {
-               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-               retval = zend_hash_find(target_symbol_table, name);
-               if (retval == NULL) {
-                       switch (type) {
-                               case BP_VAR_R:
-                               case BP_VAR_UNSET:
-                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                       /* break missing intentionally */
-                               case BP_VAR_IS:
-                                       retval = &EG(uninitialized_zval);
-                                       break;
-                               case BP_VAR_RW:
-                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                       /* break missing intentionally */
-                               case BP_VAR_W:
-                                       retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
-                                       break;
-                               EMPTY_SWITCH_DEFAULT_CASE()
-                       }
-               /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
-               } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
-                       retval = Z_INDIRECT_P(retval);
-                       if (Z_TYPE_P(retval) == IS_UNDEF) {
-                               switch (type) {
-                                       case BP_VAR_R:
-                                       case BP_VAR_UNSET:
-                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                               /* break missing intentionally */
-                                       case BP_VAR_IS:
-                                               retval = &EG(uninitialized_zval);
-                                               break;
-                                       case BP_VAR_RW:
-                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                               /* break missing intentionally */
-                                       case BP_VAR_W:
-                                               ZVAL_NULL(retval);
-                                               break;
-                                       EMPTY_SWITCH_DEFAULT_CASE()
-                               }
-                       }
-               }
-               if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
-                       if (Z_CONSTANT_P(retval)) {
-                               zval_update_constant(retval, 1 TSRMLS_CC);
-                       }
-               } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
-                       zval_ptr_dtor_nogc(free_op1);
-               }
-       }
-
-       if (IS_TMP_VAR != IS_CONST) {
-               zend_string_release(name);
-       }
-
-       ZEND_ASSERT(retval != NULL);
-       if (type == BP_VAR_R || type == BP_VAR_IS) {
-               if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
-                       ZVAL_UNREF(retval);
-               }
-               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-       } else {
-               ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
-       }
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_R_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_TMP_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_W_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_TMP_CONST(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_RW_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_TMP_CONST(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_FUNC_ARG_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-               return zend_fetch_var_address_helper_SPEC_TMP_CONST(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else {
-               return zend_fetch_var_address_helper_SPEC_TMP_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_UNSET_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_TMP_CONST(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_IS_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_TMP_CONST(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *container;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-       zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
-
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *container;
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *container;
 
        SAVE_OPLINE();
        container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
@@ -10981,21 +10144,6 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_TMP_CONST_HANDLER(ZEND_OPCO
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_CASE_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *result = EX_VAR(opline->result.var);
-
-       SAVE_OPLINE();
-       fast_equal_function(result,
-                _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-                opline->op2.zv TSRMLS_CC);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
 static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
@@ -11115,153 +10263,6 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HAN
        }
 }
 
-static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval tmp, *varname;
-       HashTable *target_symbol_table;
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-       if (IS_TMP_VAR == IS_CV &&
-           IS_CONST == IS_UNUSED &&
-           (opline->extended_value & ZEND_QUICK_SET)) {
-               zval *var = EX_VAR(opline->op1.var);
-
-               if (Z_REFCOUNTED_P(var)) {
-                       zend_refcounted *garbage = Z_COUNTED_P(var);
-
-                       if (!--GC_REFCOUNT(garbage)) {
-                               ZVAL_UNDEF(var);
-                               _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
-                       } else {
-                               GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
-                               ZVAL_UNDEF(var);
-                       }
-               } else {
-                       ZVAL_UNDEF(var);
-               }
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
-
-       varname = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
-       ZVAL_UNDEF(&tmp);
-       if (IS_TMP_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-               ZVAL_STR(&tmp, zval_get_string(varname));
-               varname = &tmp;
-       }
-
-       if (IS_CONST != IS_UNUSED) {
-               zend_class_entry *ce;
-
-               if (IS_CONST == IS_CONST) {
-                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                       } else {
-                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                               if (UNEXPECTED(EG(exception) != NULL)) {
-                                       if (IS_TMP_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-                                               zend_string_release(Z_STR(tmp));
-                                       }
-                                       zval_ptr_dtor_nogc(free_op1);
-                                       HANDLE_EXCEPTION();
-                               }
-                               if (UNEXPECTED(ce == NULL)) {
-                                       zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
-                               }
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
-                       }
-               } else {
-                       ce = Z_CE_P(EX_VAR(opline->op2.var));
-               }
-               zend_std_unset_static_property(ce, Z_STR_P(varname), ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
-       } else {
-               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-               zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
-       }
-
-       if (IS_TMP_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-               zend_string_release(Z_STR(tmp));
-       }
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *value;
-
-       SAVE_OPLINE();
-       if (IS_TMP_VAR == IS_CV &&
-           IS_CONST == IS_UNUSED &&
-           (opline->extended_value & ZEND_QUICK_SET)) {
-               value = EX_VAR(opline->op1.var);
-               if (opline->extended_value & ZEND_ISSET) {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               !i_zend_is_true(value TSRMLS_CC));
-                       CHECK_EXCEPTION();
-               }
-               ZEND_VM_NEXT_OPCODE();
-       } else {
-               zend_free_op free_op1;
-               zval tmp, *varname = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
-               ZVAL_UNDEF(&tmp);
-               if (IS_TMP_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-                       ZVAL_STR(&tmp, zval_get_string(varname));
-                       varname = &tmp;
-               }
-
-               if (IS_CONST != IS_UNUSED) {
-                       zend_class_entry *ce;
-
-                       if (IS_CONST == IS_CONST) {
-                               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                                       ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                               } else {
-                                       ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                                       if (UNEXPECTED(ce == NULL)) {
-                                               CHECK_EXCEPTION();
-                                               ZEND_VM_NEXT_OPCODE();
-                                       }
-                                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
-                               }
-                       } else {
-                               ce = Z_CE_P(EX_VAR(opline->op2.var));
-                       }
-                       value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
-               } else {
-                       HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-                       value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
-               }
-
-               if (IS_TMP_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-                       zend_string_release(Z_STR(tmp));
-               }
-               zval_ptr_dtor_nogc(free_op1);
-
-               if (opline->extended_value & ZEND_ISSET) {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               value && Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               !value || !i_zend_is_true(value TSRMLS_CC));
-               }
-
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
-}
-
 static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
@@ -11343,7 +10344,7 @@ num_index_prop:
 
                result = 0;
                if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
-                       if (IS_CONST == IS_CV || IS_CONST == IS_VAR) {
+                       if (IS_CONST & (IS_CV|IS_VAR)) {
                                ZVAL_DEREF(offset);
                        }
                        if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
@@ -11809,584 +10810,409 @@ static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_TMP_TMP_HANDLER(ZEND_OPCO
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_YIELD_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
-       zval *container;
-       zend_free_op free_op2;
-       zval *offset;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-       offset  = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
 
-       if ((IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
-           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
-               zend_error(E_NOTICE, "Trying to get property of non-object");
-               ZVAL_NULL(EX_VAR(opline->result.var));
-       } else {
-               zval *retval;
+       /* The generator object is stored in EX(return_value) */
+       zend_generator *generator = (zend_generator *) EX(return_value);
 
-               /* here we are sure we are dealing with an object */
-               do {
-                       if (IS_TMP_VAR == IS_CONST &&
-                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
-                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
-                               zend_object *zobj = Z_OBJ_P(container);
+       if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
+               zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
+       }
 
-                               if (EXPECTED(prop_info)) {
-                                       retval = OBJ_PROP(zobj, prop_info->offset);
-                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               } else if (EXPECTED(zobj->properties != NULL)) {
-                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
-                                       if (EXPECTED(retval)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               }
-                       }
+       /* Destroy the previously yielded value */
+       zval_ptr_dtor(&generator->value);
 
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+       /* Destroy the previously yielded key */
+       zval_ptr_dtor(&generator->key);
 
-                       if (retval != EX_VAR(opline->result.var)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                       }
-               } while (0);
-       }
+       /* Set the new yielded value */
+       if (IS_TMP_VAR != IS_UNUSED) {
+               zend_free_op free_op1;
 
-       zval_ptr_dtor_nogc(free_op2);
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+               if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
+                       /* Constants and temporary variables aren't yieldable by reference,
+                        * but we still allow them with a notice. */
+                       if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
+                               zval *value;
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *container;
-       zend_free_op free_op2;
-       zval *offset;
+                               zend_error(E_NOTICE, "Only variable references should be yielded by reference");
 
-       SAVE_OPLINE();
-       container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-       offset  = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+                               value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+                               ZVAL_COPY_VALUE(&generator->value, value);
+                               if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
 
-       if ((IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
-           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
-               ZVAL_NULL(EX_VAR(opline->result.var));
-       } else {
-               zval *retval;
+                               /* Temporary variables don't need ctor copying */
+                               if (IS_TMP_VAR != IS_TMP_VAR) {
+                                       zval_opt_copy_ctor(&generator->value);
+                               }
+                       } else {
+                               zval *value_ptr = NULL;
 
-               /* here we are sure we are dealing with an object */
-               do {
-                       if (IS_TMP_VAR == IS_CONST &&
-                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
-                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
-                               zend_object *zobj = Z_OBJ_P(container);
+                               if (IS_TMP_VAR == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+                                       zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
+                               }
 
-                               if (EXPECTED(prop_info)) {
-                                       retval = OBJ_PROP(zobj, prop_info->offset);
-                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               } else if (EXPECTED(zobj->properties != NULL)) {
-                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
-                                       if (EXPECTED(retval)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
+                               /* If a function call result is yielded and the function did
+                                * not return by reference we throw a notice. */
+                               if (IS_TMP_VAR == IS_VAR &&
+                                   (value_ptr == &EG(uninitialized_zval) ||
+                                    (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+                                     !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+                                       zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+                               } else {
+                                       ZVAL_MAKE_REF(value_ptr);
                                }
+                               ZVAL_COPY(&generator->value, value_ptr);
+
                        }
+               } else {
+                       zval *value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
 
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+                       /* Consts, temporary variables and references need copying */
+                       if (IS_TMP_VAR == IS_CONST) {
+                               ZVAL_DUP(&generator->value, value);
+                       } else if (IS_TMP_VAR == IS_TMP_VAR) {
+                               ZVAL_COPY_VALUE(&generator->value, value);
+            } else if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) && Z_ISREF_P(value)) {
+                               ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
 
-                       if (retval != EX_VAR(opline->result.var)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                       } else {
+                               ZVAL_COPY_VALUE(&generator->value, value);
+                               if (IS_TMP_VAR == IS_CV) {
+                                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+                               }
                        }
-               } while (0);
+               }
+       } else {
+               /* If no value was specified yield null */
+               ZVAL_NULL(&generator->value);
        }
 
-       zval_ptr_dtor_nogc(free_op2);
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *container;
-
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-               /* Behave like FETCH_OBJ_W */
-               zend_free_op free_op1, free_op2;
-               zval *property;
+       /* Set the new yielded key */
+       if (IS_TMP_VAR != IS_UNUSED) {
+               zend_free_op free_op2;
+               zval *key = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
 
-               SAVE_OPLINE();
-               property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-               container = NULL;
+               /* Consts, temporary variables and references need copying */
+               if (IS_TMP_VAR == IS_CONST) {
+                       ZVAL_DUP(&generator->key, key);
+               } else if (IS_TMP_VAR == IS_TMP_VAR) {
+                       ZVAL_COPY_VALUE(&generator->key, key);
+               } else if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && Z_ISREF_P(key)) {
+                       ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
 
-        if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
-            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
-        }
-               if (IS_TMP_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+               } else {
+                       ZVAL_COPY_VALUE(&generator->key, key);
+                       if (IS_TMP_VAR == IS_CV) {
+                               if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
+                       }
                }
-               zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_TMP_VAR, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op2);
-               if (IS_TMP_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
-                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+
+               if (Z_TYPE(generator->key) == IS_LONG
+                   && Z_LVAL(generator->key) > generator->largest_used_integer_key
+               ) {
+                       generator->largest_used_integer_key = Z_LVAL(generator->key);
                }
+       } else {
+               /* If no key was specified we use auto-increment keys */
+               generator->largest_used_integer_key++;
+               ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
+       }
 
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
+       if (RETURN_VALUE_USED(opline)) {
+               /* If the return value of yield is used set the send
+                * target and initialize it to NULL */
+               generator->send_target = EX_VAR(opline->result.var);
+               ZVAL_NULL(generator->send_target);
        } else {
-               return ZEND_FETCH_OBJ_R_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               generator->send_target = NULL;
        }
-}
 
-static int ZEND_FASTCALL  ZEND_ADD_VAR_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
-       zval *str = EX_VAR(opline->result.var);
-       zval *var;
-       zval var_copy;
-       int use_copy = 0;
+       /* We increment to the next op, so we are at the correct position when the
+        * generator is resumed. */
+       ZEND_VM_INC_OPCODE();
 
+       /* The GOTO VM uses a local opline variable. We need to set the opline
+        * variable in execute_data so we don't resume at an old position. */
        SAVE_OPLINE();
-       var = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-
-       if (IS_TMP_VAR == IS_UNUSED) {
-               /* Initialize for erealloc in add_string_to_string */
-               ZVAL_EMPTY_STRING(str);
-       }
 
-       if (Z_TYPE_P(var) != IS_STRING) {
-               if (IS_TMP_VAR != IS_TMP_VAR) {
-                       ZVAL_DEREF(var);
-               }
-               if (Z_TYPE_P(var) != IS_STRING) {
-                       use_copy = zend_make_printable_zval(var, &var_copy TSRMLS_CC);
+       ZEND_VM_RETURN();
+}
 
-                       if (use_copy) {
-                               var = &var_copy;
-                       }
-               }
-       }
-       add_string_to_string(str, str, var);
+static int ZEND_FASTCALL  ZEND_POW_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1, free_op2;
 
-       if (use_copy) {
-               zend_string_release(Z_STR_P(var));
-       }
-       /* original comment, possibly problematic:
-        * FREE_OP is missing intentionally here - we're always working on the same temporary variable
-        * (Zeev):  I don't think it's problematic, we only use variables
-        * which aren't affected by FREE_OP(Ts, )'s anyway, unless they're
-        * string offsets or overloaded objects
-        */
+       SAVE_OPLINE();
+       pow_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
        zval_ptr_dtor_nogc(free_op2);
-
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_MOD_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *function_name;
        zend_free_op free_op1, free_op2;
-       zval *object;
-       zend_function *fbc;
-       zend_class_entry *called_scope;
-       zend_object *obj;
 
        SAVE_OPLINE();
+       fast_mod_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
+       zval_ptr_dtor_nogc(free_op2);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       function_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+static int ZEND_FASTCALL  ZEND_SL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1, free_op2;
 
-       if (IS_TMP_VAR != IS_CONST &&
-           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       HANDLE_EXCEPTION();
-               }
-               zend_error_noreturn(E_ERROR, "Method name must be a string");
-       }
-
-       object = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
-               uint32_t nesting = 1;
-
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       zval_ptr_dtor_nogc(free_op2);
-                       HANDLE_EXCEPTION();
-               }
-
-               zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s",  Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
-               zval_ptr_dtor_nogc(free_op2);
-
-               if (EG(exception) != NULL) {
-                       HANDLE_EXCEPTION();
-               }
-
-               /* No exception raised: Skip over arguments until fcall opcode with correct
-                * nesting level. Return NULL (except when return value unused) */
-               do {
-                       opline++;
-                       if (opline->opcode == ZEND_INIT_FCALL ||
-                               opline->opcode == ZEND_INIT_FCALL_BY_NAME ||
-                               opline->opcode == ZEND_INIT_NS_FCALL_BY_NAME ||
-                               opline->opcode == ZEND_INIT_METHOD_CALL ||
-                               opline->opcode == ZEND_INIT_STATIC_METHOD_CALL ||
-                               opline->opcode == ZEND_INIT_USER_CALL ||
-                               opline->opcode == ZEND_NEW
-                       ) {
-                               nesting++;
-                       } else if (opline->opcode == ZEND_DO_FCALL) {
-                               nesting--;
-                       }
-               } while (nesting);
-
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
-               }
-
-               /* We've skipped EXT_FCALL_BEGIND, so also skip the ending opcode */
-               if ((opline + 1)->opcode == ZEND_EXT_FCALL_END) {
-                       opline++;
-               }
-               ZEND_VM_JMP(++opline);
-       }
-
-       obj = Z_OBJ_P(object);
-       called_scope = obj->ce;
+       SAVE_OPLINE();
+       shift_left_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
+       zval_ptr_dtor_nogc(free_op2);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       if (IS_TMP_VAR != IS_CONST ||
-           EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
-           zend_object *orig_obj = obj;
+static int ZEND_FASTCALL  ZEND_SR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1, free_op2;
 
-               if (UNEXPECTED(obj->handlers->get_method == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Object does not support method calls");
-               }
+       SAVE_OPLINE();
+       shift_right_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
+       zval_ptr_dtor_nogc(free_op2);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-               /* First, locate the function. */
-               fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_TMP_VAR == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
-               if (UNEXPECTED(fbc == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
-               }
-               if (IS_TMP_VAR == IS_CONST &&
-                   EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
-                   EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
-                   EXPECTED(obj == orig_obj)) {
-                       CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope, fbc);
-               }
-       }
+static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1, free_op2;
 
-       if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_STATIC) != 0)) {
-               obj = NULL;
-       } else {
-               GC_REFCOUNT(obj)++; /* For $this pointer */
-       }
+       SAVE_OPLINE();
+       concat_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
+       zval_ptr_dtor_nogc(free_op2);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
-               fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
+static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
+       fast_is_identical_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
        zval_ptr_dtor_nogc(free_op2);
-
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_CASE_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = EX_VAR(opline->result.var);
 
        SAVE_OPLINE();
-       fast_equal_function(result,
-                _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-                _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
-
+       fast_is_not_identical_function(result,
+               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
        zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
-       zval *expr_ptr, new_expr;
+       zend_free_op free_op1, free_op2;
 
        SAVE_OPLINE();
-       if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) &&
-           (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
-               expr_ptr = NULL;
-               if (IS_TMP_VAR == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
-               }
-               ZVAL_MAKE_REF(expr_ptr);
-               Z_ADDREF_P(expr_ptr);
+       bitwise_or_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
+       zval_ptr_dtor_nogc(free_op2);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       } else {
-               expr_ptr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-               if (IS_TMP_VAR == IS_TMP_VAR) {
-                       ZVAL_COPY_VALUE(&new_expr, expr_ptr);
-                       expr_ptr = &new_expr;
-               } else if (IS_TMP_VAR == IS_CONST) {
-                       if (!Z_IMMUTABLE_P(expr_ptr)) {
-                               ZVAL_DUP(&new_expr, expr_ptr);
-                               expr_ptr = &new_expr;
-                       }
-               } else if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) && Z_ISREF_P(expr_ptr)) {
-                       expr_ptr = Z_REFVAL_P(expr_ptr);
-                       if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
+static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1, free_op2;
 
-               } else if (IS_TMP_VAR == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
-                       Z_ADDREF_P(expr_ptr);
-               }
-       }
+       SAVE_OPLINE();
+       bitwise_and_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
+       zval_ptr_dtor_nogc(free_op2);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       if (IS_TMP_VAR != IS_UNUSED) {
-               zend_free_op free_op2;
-               zval *offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-               zend_string *str;
-               zend_ulong hval;
+static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1, free_op2;
 
-add_again:
-               switch (Z_TYPE_P(offset)) {
-                       case IS_DOUBLE:
-                               hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                               goto num_index;
-                       case IS_LONG:
-                               hval = Z_LVAL_P(offset);
-num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
-                               break;
-                       case IS_STRING:
-                               str = Z_STR_P(offset);
-                               if (IS_TMP_VAR != IS_CONST) {
-                                       if (ZEND_HANDLE_NUMERIC(str, hval)) {
-                                               goto num_index;
-                                       }
-                               }
-str_index:
-                               zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
-                               break;
-                       case IS_NULL:
-                               str = STR_EMPTY_ALLOC();
-                               goto str_index;
-                       case IS_FALSE:
-                               hval = 0;
-                               goto num_index;
-                       case IS_TRUE:
-                               hval = 1;
-                               goto num_index;
-                       case IS_REFERENCE:
-                               offset = Z_REFVAL_P(offset);
-                               goto add_again;
-                               break;
-                       default:
-                               zend_error(E_WARNING, "Illegal offset type");
-                               zval_ptr_dtor(expr_ptr);
-                               /* do nothing */
-                               break;
-               }
-               zval_ptr_dtor_nogc(free_op2);
-       } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
-       }
+       SAVE_OPLINE();
+       bitwise_xor_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
+       zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zval *array;
-       uint32_t size;
        USE_OPLINE
+       zend_free_op free_op1, free_op2;
 
-       array = EX_VAR(opline->result.var);
-       if (IS_TMP_VAR != IS_UNUSED) {
-               size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
-       } else {
-               size = 0;
-       }
-       ZVAL_NEW_ARR(array);
-       zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
+       SAVE_OPLINE();
+       boolean_xor_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
+       zval_ptr_dtor_nogc(free_op2);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       if (IS_TMP_VAR != IS_UNUSED) {
-               /* Explicitly initialize array as not-packed if flag is set */
-               if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
-                       zend_hash_real_init(Z_ARRVAL_P(array), 0);
-               }
-       }
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1, free_op2;
+       zval *container;
 
-       if (IS_TMP_VAR == IS_UNUSED) {
-               ZEND_VM_NEXT_OPCODE();
-#if 0 || IS_TMP_VAR != IS_UNUSED
-       } else {
-               return ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-#endif
-       }
+       SAVE_OPLINE();
+       container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+       zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
+       zval_ptr_dtor_nogc(free_op1);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *container;
-       int result;
-       zend_ulong hval;
-       zval *offset;
 
        SAVE_OPLINE();
        container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-       offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
+       zval_ptr_dtor_nogc(free_op1);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       if (IS_TMP_VAR != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
-               HashTable *ht = Z_ARRVAL_P(container);
-               zval *value;
-               zend_string *str;
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zval *container;
+       zend_free_op free_op1, free_op2;
 
-isset_again:
-               if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
-                       str = Z_STR_P(offset);
-                       if (IS_TMP_VAR != IS_CONST) {
-                               if (ZEND_HANDLE_NUMERIC(str, hval)) {
-                                       goto num_index_prop;
-                               }
-                       }
-str_index_prop:
-                       value = zend_hash_find_ind(ht, str);
-               } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
-                       hval = Z_LVAL_P(offset);
-num_index_prop:
-                       value = zend_hash_index_find(ht, hval);
-               } else {
-                       switch (Z_TYPE_P(offset)) {
-                               case IS_DOUBLE:
-                                       hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                                       goto num_index_prop;
-                               case IS_NULL:
-                                       str = STR_EMPTY_ALLOC();
-                                       goto str_index_prop;
-                               case IS_FALSE:
-                                       hval = 0;
-                                       goto num_index_prop;
-                               case IS_TRUE:
-                                       hval = 1;
-                                       goto num_index_prop;
-                               case IS_RESOURCE:
-                                       hval = Z_RES_HANDLE_P(offset);
-                                       goto num_index_prop;
-                               case IS_REFERENCE:
-                                       offset = Z_REFVAL_P(offset);
-                                       goto isset_again;
-                               default:
-                                       zend_error(E_WARNING, "Illegal offset type in isset or empty");
-                                       value = NULL;
-                                       break;
-                       }
-               }
+       SAVE_OPLINE();
 
-               if (opline->extended_value & ZEND_ISSET) {
-                       /* > IS_NULL means not IS_UNDEF and not IS_NULL */
-                       result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
-               }
-       } else if (IS_TMP_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
-                       result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
-               } else {
-                       zend_error(E_NOTICE, "Trying to check element of non-array");
-                       result = 0;
+       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+        if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
+            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+        }
+               container = NULL;
+               if (IS_TMP_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
+               ZVAL_DEREF(container);
+               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+               if (IS_TMP_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
+                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
                }
-       } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
-               zval tmp;
+               zval_ptr_dtor_nogc(free_op2);
 
-               result = 0;
-               if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
-                       if (IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) {
-                               ZVAL_DEREF(offset);
-                       }
-                       if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
-                                       || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
-                                               && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
-                               ZVAL_DUP(&tmp, offset);
-                               convert_to_long(&tmp);
-                               offset = &tmp;
-                       }
-               }
-               if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
-                       if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
-                               if ((opline->extended_value & ZEND_ISSET) ||
-                                   Z_STRVAL_P(container)[offset->value.lval] != '0') {
-                                       result = 1;
-                               }
-                       }
-               }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
-               }
        } else {
-               result = ((opline->extended_value & ZEND_ISSET) == 0);
+               if (IS_VAR == IS_UNUSED) {
+                       zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
+               }
+               container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+               zval_ptr_dtor_nogc(free_op2);
+               zval_ptr_dtor_nogc(free_op1);
        }
-
-       zval_ptr_dtor_nogc(free_op2);
-       ZVAL_BOOL(EX_VAR(opline->result.var), result);
-       zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INSTANCEOF_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
-       zval *container;
-       int result;
-       zval *offset;
+       zend_free_op free_op1;
+       zval *expr;
+       zend_bool result;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-       offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       expr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
 
-       if (IS_TMP_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
-                       result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+       if (Z_TYPE_P(expr) == IS_OBJECT) {
+               zend_class_entry *ce;
+
+               if (IS_VAR == IS_CONST) {
+                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+                       } else {
+                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, ZEND_FETCH_CLASS_NO_AUTOLOAD TSRMLS_CC);
+                               if (UNEXPECTED(ce == NULL)) {
+                                       ZVAL_FALSE(EX_VAR(opline->result.var));
+                                       zval_ptr_dtor_nogc(free_op1);
+                                       CHECK_EXCEPTION();
+                                       ZEND_VM_NEXT_OPCODE();
+                               }
+                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+                       }
                } else {
-                       zend_error(E_NOTICE, "Trying to check property of non-object");
-                       result = 0;
-               }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
+                       ce = Z_CE_P(EX_VAR(opline->op2.var));
                }
+               result = instanceof_function(Z_OBJCE_P(expr), ce TSRMLS_CC);
        } else {
-               result = ((opline->extended_value & ZEND_ISSET) == 0);
+               result = 0;
        }
-
-       zval_ptr_dtor_nogc(free_op2);
        ZVAL_BOOL(EX_VAR(opline->result.var), result);
        zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_YIELD_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_YIELD_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
@@ -12467,21 +11293,21 @@ static int ZEND_FASTCALL  ZEND_YIELD_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_AR
        }
 
        /* Set the new yielded key */
-       if (IS_TMP_VAR != IS_UNUSED) {
+       if (IS_VAR != IS_UNUSED) {
                zend_free_op free_op2;
-               zval *key = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+               zval *key = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
                /* Consts, temporary variables and references need copying */
-               if (IS_TMP_VAR == IS_CONST) {
+               if (IS_VAR == IS_CONST) {
                        ZVAL_DUP(&generator->key, key);
-               } else if (IS_TMP_VAR == IS_TMP_VAR) {
+               } else if (IS_VAR == IS_TMP_VAR) {
                        ZVAL_COPY_VALUE(&generator->key, key);
-               } else if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && Z_ISREF_P(key)) {
+               } else if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && Z_ISREF_P(key)) {
                        ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
-
+                       zval_ptr_dtor_nogc(free_op2);
                } else {
                        ZVAL_COPY_VALUE(&generator->key, key);
-                       if (IS_TMP_VAR == IS_CV) {
+                       if (IS_VAR == IS_CV) {
                                if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
                        }
                }
@@ -12517,7 +11343,7 @@ static int ZEND_FASTCALL  ZEND_YIELD_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_AR
        ZEND_VM_RETURN();
 }
 
-static int ZEND_FASTCALL  ZEND_POW_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_POW_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
@@ -12525,347 +11351,485 @@ static int ZEND_FASTCALL  ZEND_POW_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS
        SAVE_OPLINE();
        pow_function(EX_VAR(opline->result.var),
                _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
        zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_MOD_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zval *container;
+       zend_free_op free_op1;
 
        SAVE_OPLINE();
-       fast_mod_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
-       zval_ptr_dtor_nogc(free_op2);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
 
-static int ZEND_FASTCALL  ZEND_SL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+        if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
+            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+        }
+               container = NULL;
+               if (IS_TMP_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+               }
+               ZVAL_DEREF(container);
+               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
+               if (IS_TMP_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
+                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+               }
 
-       SAVE_OPLINE();
-       shift_left_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
-       zval_ptr_dtor_nogc(free_op2);
+
+       } else {
+               if (IS_UNUSED == IS_UNUSED) {
+                       zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
+               }
+               container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
+
+               zval_ptr_dtor_nogc(free_op1);
+       }
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_SR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
+       zval *expr_ptr, new_expr;
 
        SAVE_OPLINE();
-       shift_right_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
-       zval_ptr_dtor_nogc(free_op2);
+       if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) &&
+           (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
+               expr_ptr = NULL;
+               if (IS_TMP_VAR == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
+               }
+               ZVAL_MAKE_REF(expr_ptr);
+               Z_ADDREF_P(expr_ptr);
+
+       } else {
+               expr_ptr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+               if (IS_TMP_VAR == IS_TMP_VAR) {
+                       ZVAL_COPY_VALUE(&new_expr, expr_ptr);
+                       expr_ptr = &new_expr;
+               } else if (IS_TMP_VAR == IS_CONST) {
+                       if (!Z_IMMUTABLE_P(expr_ptr)) {
+                               ZVAL_DUP(&new_expr, expr_ptr);
+                               expr_ptr = &new_expr;
+                       }
+               } else if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) && Z_ISREF_P(expr_ptr)) {
+                       expr_ptr = Z_REFVAL_P(expr_ptr);
+                       if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
+
+               } else if (IS_TMP_VAR == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
+                       Z_ADDREF_P(expr_ptr);
+               }
+       }
+
+       if (IS_UNUSED != IS_UNUSED) {
+
+               zval *offset = NULL;
+               zend_string *str;
+               zend_ulong hval;
+
+add_again:
+               switch (Z_TYPE_P(offset)) {
+                       case IS_DOUBLE:
+                               hval = zend_dval_to_lval(Z_DVAL_P(offset));
+                               goto num_index;
+                       case IS_LONG:
+                               hval = Z_LVAL_P(offset);
+num_index:
+                               zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
+                               break;
+                       case IS_STRING:
+                               str = Z_STR_P(offset);
+                               if (IS_UNUSED != IS_CONST) {
+                                       if (ZEND_HANDLE_NUMERIC(str, hval)) {
+                                               goto num_index;
+                                       }
+                               }
+str_index:
+                               zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
+                               break;
+                       case IS_NULL:
+                               str = STR_EMPTY_ALLOC();
+                               goto str_index;
+                       case IS_FALSE:
+                               hval = 0;
+                               goto num_index;
+                       case IS_TRUE:
+                               hval = 1;
+                               goto num_index;
+                       case IS_REFERENCE:
+                               offset = Z_REFVAL_P(offset);
+                               goto add_again;
+                               break;
+                       default:
+                               zend_error(E_WARNING, "Illegal offset type");
+                               zval_ptr_dtor(expr_ptr);
+                               /* do nothing */
+                               break;
+               }
+
+       } else {
+               zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
+       }
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
+       zval *array;
+       uint32_t size;
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
 
+       array = EX_VAR(opline->result.var);
+       if (IS_TMP_VAR != IS_UNUSED) {
+               size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
+       } else {
+               size = 0;
+       }
+       ZVAL_NEW_ARR(array);
+       zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
+
+       if (IS_TMP_VAR != IS_UNUSED) {
+               /* Explicitly initialize array as not-packed if flag is set */
+               if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
+                       zend_hash_real_init(Z_ARRVAL_P(array), 0);
+               }
+       }
+
+       if (IS_TMP_VAR == IS_UNUSED) {
+               ZEND_VM_NEXT_OPCODE();
+#if 0 || IS_TMP_VAR != IS_UNUSED
+       } else {
+               return ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+#endif
+       }
+}
+
+static int ZEND_FASTCALL  ZEND_YIELD_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       /* The generator object is stored in EX(return_value) */
+       zend_generator *generator = (zend_generator *) EX(return_value);
+
+       if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
+               zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
+       }
+
+       /* Destroy the previously yielded value */
+       zval_ptr_dtor(&generator->value);
+
+       /* Destroy the previously yielded key */
+       zval_ptr_dtor(&generator->key);
+
+       /* Set the new yielded value */
+       if (IS_TMP_VAR != IS_UNUSED) {
+               zend_free_op free_op1;
+
+               if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
+                       /* Constants and temporary variables aren't yieldable by reference,
+                        * but we still allow them with a notice. */
+                       if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
+                               zval *value;
+
+                               zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+
+                               value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+                               ZVAL_COPY_VALUE(&generator->value, value);
+                               if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
+
+                               /* Temporary variables don't need ctor copying */
+                               if (IS_TMP_VAR != IS_TMP_VAR) {
+                                       zval_opt_copy_ctor(&generator->value);
+                               }
+                       } else {
+                               zval *value_ptr = NULL;
+
+                               if (IS_TMP_VAR == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+                                       zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
+                               }
+
+                               /* If a function call result is yielded and the function did
+                                * not return by reference we throw a notice. */
+                               if (IS_TMP_VAR == IS_VAR &&
+                                   (value_ptr == &EG(uninitialized_zval) ||
+                                    (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+                                     !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+                                       zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+                               } else {
+                                       ZVAL_MAKE_REF(value_ptr);
+                               }
+                               ZVAL_COPY(&generator->value, value_ptr);
+
+                       }
+               } else {
+                       zval *value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+
+                       /* Consts, temporary variables and references need copying */
+                       if (IS_TMP_VAR == IS_CONST) {
+                               ZVAL_DUP(&generator->value, value);
+                       } else if (IS_TMP_VAR == IS_TMP_VAR) {
+                               ZVAL_COPY_VALUE(&generator->value, value);
+            } else if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) && Z_ISREF_P(value)) {
+                               ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
+
+                       } else {
+                               ZVAL_COPY_VALUE(&generator->value, value);
+                               if (IS_TMP_VAR == IS_CV) {
+                                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+                               }
+                       }
+               }
+       } else {
+               /* If no value was specified yield null */
+               ZVAL_NULL(&generator->value);
+       }
+
+       /* Set the new yielded key */
+       if (IS_UNUSED != IS_UNUSED) {
+
+               zval *key = NULL;
+
+               /* Consts, temporary variables and references need copying */
+               if (IS_UNUSED == IS_CONST) {
+                       ZVAL_DUP(&generator->key, key);
+               } else if (IS_UNUSED == IS_TMP_VAR) {
+                       ZVAL_COPY_VALUE(&generator->key, key);
+               } else if ((IS_UNUSED == IS_VAR || IS_UNUSED == IS_CV) && Z_ISREF_P(key)) {
+                       ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
+
+               } else {
+                       ZVAL_COPY_VALUE(&generator->key, key);
+                       if (IS_UNUSED == IS_CV) {
+                               if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
+                       }
+               }
+
+               if (Z_TYPE(generator->key) == IS_LONG
+                   && Z_LVAL(generator->key) > generator->largest_used_integer_key
+               ) {
+                       generator->largest_used_integer_key = Z_LVAL(generator->key);
+               }
+       } else {
+               /* If no key was specified we use auto-increment keys */
+               generator->largest_used_integer_key++;
+               ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
+       }
+
+       if (RETURN_VALUE_USED(opline)) {
+               /* If the return value of yield is used set the send
+                * target and initialize it to NULL */
+               generator->send_target = EX_VAR(opline->result.var);
+               ZVAL_NULL(generator->send_target);
+       } else {
+               generator->send_target = NULL;
+       }
+
+       /* We increment to the next op, so we are at the correct position when the
+        * generator is resumed. */
+       ZEND_VM_INC_OPCODE();
+
+       /* The GOTO VM uses a local opline variable. We need to set the opline
+        * variable in execute_data so we don't resume at an old position. */
        SAVE_OPLINE();
-       concat_function(EX_VAR(opline->result.var),
+
+       ZEND_VM_RETURN();
+}
+
+static int ZEND_FASTCALL  ZEND_MOD_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+
+       SAVE_OPLINE();
+       fast_mod_function(EX_VAR(opline->result.var),
                _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
-       zval_ptr_dtor_nogc(free_op2);
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SL_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
 
        SAVE_OPLINE();
-       fast_is_identical_function(EX_VAR(opline->result.var),
+       shift_left_function(EX_VAR(opline->result.var),
                _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
-       zval_ptr_dtor_nogc(free_op2);
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
-       zval *result = EX_VAR(opline->result.var);
+       zend_free_op free_op1;
 
        SAVE_OPLINE();
-       fast_is_not_identical_function(result,
+       shift_right_function(EX_VAR(opline->result.var),
                _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
-       zval_ptr_dtor_nogc(free_op2);
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
 
        SAVE_OPLINE();
-       bitwise_or_function(EX_VAR(opline->result.var),
+       concat_function(EX_VAR(opline->result.var),
                _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
-       zval_ptr_dtor_nogc(free_op2);
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
 
        SAVE_OPLINE();
-       bitwise_and_function(EX_VAR(opline->result.var),
+       fast_is_identical_function(EX_VAR(opline->result.var),
                _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
-       zval_ptr_dtor_nogc(free_op2);
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
+       zval *result = EX_VAR(opline->result.var);
 
        SAVE_OPLINE();
-       bitwise_xor_function(EX_VAR(opline->result.var),
+       fast_is_not_identical_function(result,
                _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
-       zval_ptr_dtor_nogc(free_op2);
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
 
        SAVE_OPLINE();
-       boolean_xor_function(EX_VAR(opline->result.var),
+       bitwise_or_function(EX_VAR(opline->result.var),
                _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
-       zval_ptr_dtor_nogc(free_op2);
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_TMP_VAR(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
-       zval *varname;
-       zval *retval;
-       zend_string *name;
-       HashTable *target_symbol_table;
 
        SAVE_OPLINE();
-       varname = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_TMP_VAR == IS_CONST) {
-               name = Z_STR_P(varname);
-       } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
-               name = Z_STR_P(varname);
-               zend_string_addref(name);
-       } else {
-               name = zval_get_string(varname);
-       }
-
-       if (IS_VAR != IS_UNUSED) {
-               zend_class_entry *ce;
-
-               if (IS_VAR == IS_CONST) {
-                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                       } else {
-                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                               if (UNEXPECTED(ce == NULL)) {
-                                       if (IS_TMP_VAR != IS_CONST) {
-                                               zend_string_release(name);
-                                       }
-                                       zval_ptr_dtor_nogc(free_op1);
-                                       CHECK_EXCEPTION();
-                                       ZEND_VM_NEXT_OPCODE();
-                               }
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
-                       }
-               } else {
-                       ce = Z_CE_P(EX_VAR(opline->op2.var));
-               }
-               retval = zend_std_get_static_property(ce, name, 0, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op1);
-       } else {
-               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-               retval = zend_hash_find(target_symbol_table, name);
-               if (retval == NULL) {
-                       switch (type) {
-                               case BP_VAR_R:
-                               case BP_VAR_UNSET:
-                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                       /* break missing intentionally */
-                               case BP_VAR_IS:
-                                       retval = &EG(uninitialized_zval);
-                                       break;
-                               case BP_VAR_RW:
-                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                       /* break missing intentionally */
-                               case BP_VAR_W:
-                                       retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
-                                       break;
-                               EMPTY_SWITCH_DEFAULT_CASE()
-                       }
-               /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
-               } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
-                       retval = Z_INDIRECT_P(retval);
-                       if (Z_TYPE_P(retval) == IS_UNDEF) {
-                               switch (type) {
-                                       case BP_VAR_R:
-                                       case BP_VAR_UNSET:
-                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                               /* break missing intentionally */
-                                       case BP_VAR_IS:
-                                               retval = &EG(uninitialized_zval);
-                                               break;
-                                       case BP_VAR_RW:
-                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                               /* break missing intentionally */
-                                       case BP_VAR_W:
-                                               ZVAL_NULL(retval);
-                                               break;
-                                       EMPTY_SWITCH_DEFAULT_CASE()
-                               }
-                       }
-               }
-               if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
-                       if (Z_CONSTANT_P(retval)) {
-                               zval_update_constant(retval, 1 TSRMLS_CC);
-                       }
-               } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
-                       zval_ptr_dtor_nogc(free_op1);
-               }
-       }
-
-       if (IS_TMP_VAR != IS_CONST) {
-               zend_string_release(name);
-       }
+       bitwise_and_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
 
-       ZEND_ASSERT(retval != NULL);
-       if (type == BP_VAR_R || type == BP_VAR_IS) {
-               if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
-                       ZVAL_UNREF(retval);
-               }
-               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-       } else {
-               ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
-       }
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_R_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_var_address_helper_SPEC_TMP_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+       USE_OPLINE
+       zend_free_op free_op1;
 
-static int ZEND_FASTCALL  ZEND_FETCH_W_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_TMP_VAR(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+       SAVE_OPLINE();
+       bitwise_xor_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
 
-static int ZEND_FASTCALL  ZEND_FETCH_RW_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_TMP_VAR(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_FUNC_ARG_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zend_free_op free_op1;
 
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-               return zend_fetch_var_address_helper_SPEC_TMP_VAR(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else {
-               return zend_fetch_var_address_helper_SPEC_TMP_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_UNSET_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_TMP_VAR(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+       SAVE_OPLINE();
+       boolean_xor_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
 
-static int ZEND_FASTCALL  ZEND_FETCH_IS_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_TMP_VAR(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
        zval *container;
 
        SAVE_OPLINE();
        container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-       zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
+       zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
+
        zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
        zval *container;
 
        SAVE_OPLINE();
        container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-       zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
+       zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
+
        zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zval *container;
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
 
        SAVE_OPLINE();
 
@@ -12878,36 +11842,36 @@ static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_TMP_VAR_HANDLER(ZEND_OPCO
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
                ZVAL_DEREF(container);
-               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
                if (IS_TMP_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
                        EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
                }
-               zval_ptr_dtor_nogc(free_op2);
+
 
        } else {
-               if (IS_VAR == IS_UNUSED) {
+               if (IS_CV == IS_UNUSED) {
                        zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
                }
                container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op2);
+               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
+
                zval_ptr_dtor_nogc(free_op1);
        }
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
        zval *container;
-       zend_free_op free_op2;
+
        zval *offset;
 
        SAVE_OPLINE();
        container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-       offset  = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+       offset  = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
 
        if ((IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
            UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
@@ -12918,7 +11882,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HAND
 
                /* here we are sure we are dealing with an object */
                do {
-                       if (IS_VAR == IS_CONST &&
+                       if (IS_CV == IS_CONST &&
                                EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
                                zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
                                zend_object *zobj = Z_OBJ_P(container);
@@ -12938,7 +11902,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HAND
                                }
                        }
 
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
 
                        if (retval != EX_VAR(opline->result.var)) {
                                ZVAL_COPY(EX_VAR(opline->result.var), retval);
@@ -12946,23 +11910,22 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HAND
                } while (0);
        }
 
-       zval_ptr_dtor_nogc(free_op2);
        zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
        zval *container;
-       zend_free_op free_op2;
+
        zval *offset;
 
        SAVE_OPLINE();
        container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-       offset  = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+       offset  = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
 
        if ((IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
            UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
@@ -12972,7 +11935,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HAN
 
                /* here we are sure we are dealing with an object */
                do {
-                       if (IS_VAR == IS_CONST &&
+                       if (IS_CV == IS_CONST &&
                                EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
                                zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
                                zend_object *zobj = Z_OBJ_P(container);
@@ -12992,7 +11955,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HAN
                                }
                        }
 
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
 
                        if (retval != EX_VAR(opline->result.var)) {
                                ZVAL_COPY(EX_VAR(opline->result.var), retval);
@@ -13000,24 +11963,23 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HAN
                } while (0);
        }
 
-       zval_ptr_dtor_nogc(free_op2);
        zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zval *container;
 
        if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
                /* Behave like FETCH_OBJ_W */
-               zend_free_op free_op1, free_op2;
+               zend_free_op free_op1;
                zval *property;
 
                SAVE_OPLINE();
-               property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+               property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
                container = NULL;
 
         if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
@@ -13026,8 +11988,8 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_TMP_VAR_HANDLER(ZEND_OPCO
                if (IS_TMP_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
                }
-               zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_TMP_VAR, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op2);
+               zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_TMP_VAR, property, IS_CV, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+
                if (IS_TMP_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
                        EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
                }
@@ -13035,21 +11997,21 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_TMP_VAR_HANDLER(ZEND_OPCO
                CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
-               return ZEND_FETCH_OBJ_R_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return ZEND_FETCH_OBJ_R_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ADD_VAR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ADD_VAR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
+
        zval *str = EX_VAR(opline->result.var);
        zval *var;
        zval var_copy;
        int use_copy = 0;
 
        SAVE_OPLINE();
-       var = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+       var = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
 
        if (IS_TMP_VAR == IS_UNUSED) {
                /* Initialize for erealloc in add_string_to_string */
@@ -13057,15 +12019,10 @@ static int ZEND_FASTCALL  ZEND_ADD_VAR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_
        }
 
        if (Z_TYPE_P(var) != IS_STRING) {
-               if (IS_VAR != IS_TMP_VAR) {
-                       ZVAL_DEREF(var);
-               }
-               if (Z_TYPE_P(var) != IS_STRING) {
-                       use_copy = zend_make_printable_zval(var, &var_copy TSRMLS_CC);
+               use_copy = zend_make_printable_zval(var, &var_copy TSRMLS_CC);
 
-                       if (use_copy) {
-                               var = &var_copy;
-                       }
+               if (use_copy) {
+                       var = &var_copy;
                }
        }
        add_string_to_string(str, str, var);
@@ -13079,17 +12036,16 @@ static int ZEND_FASTCALL  ZEND_ADD_VAR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_
         * which aren't affected by FREE_OP(Ts, )'s anyway, unless they're
         * string offsets or overloaded objects
         */
-       zval_ptr_dtor_nogc(free_op2);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zval *function_name;
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
        zval *object;
        zend_function *fbc;
        zend_class_entry *called_scope;
@@ -13097,9 +12053,9 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE
 
        SAVE_OPLINE();
 
-       function_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+       function_name = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
 
-       if (IS_VAR != IS_CONST &&
+       if (IS_CV != IS_CONST &&
            UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                if (UNEXPECTED(EG(exception) != NULL)) {
                        HANDLE_EXCEPTION();
@@ -13113,12 +12069,12 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE
                uint32_t nesting = 1;
 
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       zval_ptr_dtor_nogc(free_op2);
+
                        HANDLE_EXCEPTION();
                }
 
                zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s",  Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
-               zval_ptr_dtor_nogc(free_op2);
+
 
                if (EG(exception) != NULL) {
                        HANDLE_EXCEPTION();
@@ -13156,7 +12112,7 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE
        obj = Z_OBJ_P(object);
        called_scope = obj->ce;
 
-       if (IS_VAR != IS_CONST ||
+       if (IS_CV != IS_CONST ||
            EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
            zend_object *orig_obj = obj;
 
@@ -13165,11 +12121,11 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE
                }
 
                /* First, locate the function. */
-               fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_VAR == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
+               fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_CV == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
                if (UNEXPECTED(fbc == NULL)) {
                        zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
                }
-               if (IS_VAR == IS_CONST &&
+               if (IS_CV == IS_CONST &&
                    EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
                    EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
                    EXPECTED(obj == orig_obj)) {
@@ -13186,29 +12142,12 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE
        EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
                fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
 
-       zval_ptr_dtor_nogc(free_op2);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_CASE_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1, free_op2;
-       zval *result = EX_VAR(opline->result.var);
-
-       SAVE_OPLINE();
-       fast_equal_function(result,
-                _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-                _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
 
-       zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
@@ -13243,9 +12182,9 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_VAR_HANDLER(ZEND_OPCOD
                }
        }
 
-       if (IS_VAR != IS_UNUSED) {
-               zend_free_op free_op2;
-               zval *offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+       if (IS_CV != IS_UNUSED) {
+
+               zval *offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
                zend_string *str;
                zend_ulong hval;
 
@@ -13261,7 +12200,7 @@ num_index:
                                break;
                        case IS_STRING:
                                str = Z_STR_P(offset);
-                               if (IS_VAR != IS_CONST) {
+                               if (IS_CV != IS_CONST) {
                                        if (ZEND_HANDLE_NUMERIC(str, hval)) {
                                                goto num_index;
                                        }
@@ -13288,7 +12227,7 @@ str_index:
                                /* do nothing */
                                break;
                }
-               zval_ptr_dtor_nogc(free_op2);
+
        } else {
                zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
        }
@@ -13296,7 +12235,7 @@ str_index:
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        zval *array;
        uint32_t size;
@@ -13322,162 +12261,15 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDL
                ZEND_VM_NEXT_OPCODE();
 #if 0 || IS_TMP_VAR != IS_UNUSED
        } else {
-               return ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 #endif
        }
 }
 
-static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval tmp, *varname;
-       HashTable *target_symbol_table;
        zend_free_op free_op1;
-
-       SAVE_OPLINE();
-       if (IS_TMP_VAR == IS_CV &&
-           IS_VAR == IS_UNUSED &&
-           (opline->extended_value & ZEND_QUICK_SET)) {
-               zval *var = EX_VAR(opline->op1.var);
-
-               if (Z_REFCOUNTED_P(var)) {
-                       zend_refcounted *garbage = Z_COUNTED_P(var);
-
-                       if (!--GC_REFCOUNT(garbage)) {
-                               ZVAL_UNDEF(var);
-                               _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
-                       } else {
-                               GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
-                               ZVAL_UNDEF(var);
-                       }
-               } else {
-                       ZVAL_UNDEF(var);
-               }
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
-
-       varname = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
-       ZVAL_UNDEF(&tmp);
-       if (IS_TMP_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-               ZVAL_STR(&tmp, zval_get_string(varname));
-               varname = &tmp;
-       }
-
-       if (IS_VAR != IS_UNUSED) {
-               zend_class_entry *ce;
-
-               if (IS_VAR == IS_CONST) {
-                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                       } else {
-                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                               if (UNEXPECTED(EG(exception) != NULL)) {
-                                       if (IS_TMP_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-                                               zend_string_release(Z_STR(tmp));
-                                       }
-                                       zval_ptr_dtor_nogc(free_op1);
-                                       HANDLE_EXCEPTION();
-                               }
-                               if (UNEXPECTED(ce == NULL)) {
-                                       zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
-                               }
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
-                       }
-               } else {
-                       ce = Z_CE_P(EX_VAR(opline->op2.var));
-               }
-               zend_std_unset_static_property(ce, Z_STR_P(varname), ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
-       } else {
-               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-               zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
-       }
-
-       if (IS_TMP_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-               zend_string_release(Z_STR(tmp));
-       }
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *value;
-
-       SAVE_OPLINE();
-       if (IS_TMP_VAR == IS_CV &&
-           IS_VAR == IS_UNUSED &&
-           (opline->extended_value & ZEND_QUICK_SET)) {
-               value = EX_VAR(opline->op1.var);
-               if (opline->extended_value & ZEND_ISSET) {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               !i_zend_is_true(value TSRMLS_CC));
-                       CHECK_EXCEPTION();
-               }
-               ZEND_VM_NEXT_OPCODE();
-       } else {
-               zend_free_op free_op1;
-               zval tmp, *varname = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
-               ZVAL_UNDEF(&tmp);
-               if (IS_TMP_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-                       ZVAL_STR(&tmp, zval_get_string(varname));
-                       varname = &tmp;
-               }
-
-               if (IS_VAR != IS_UNUSED) {
-                       zend_class_entry *ce;
-
-                       if (IS_VAR == IS_CONST) {
-                               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                                       ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                               } else {
-                                       ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                                       if (UNEXPECTED(ce == NULL)) {
-                                               CHECK_EXCEPTION();
-                                               ZEND_VM_NEXT_OPCODE();
-                                       }
-                                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
-                               }
-                       } else {
-                               ce = Z_CE_P(EX_VAR(opline->op2.var));
-                       }
-                       value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
-               } else {
-                       HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-                       value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
-               }
-
-               if (IS_TMP_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-                       zend_string_release(Z_STR(tmp));
-               }
-               zval_ptr_dtor_nogc(free_op1);
-
-               if (opline->extended_value & ZEND_ISSET) {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               value && Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               !value || !i_zend_is_true(value TSRMLS_CC));
-               }
-
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1, free_op2;
        zval *container;
        int result;
        zend_ulong hval;
@@ -13485,7 +12277,7 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_VAR_HANDLER(ZEND_O
 
        SAVE_OPLINE();
        container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+       offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
 
        if (IS_TMP_VAR != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
                HashTable *ht = Z_ARRVAL_P(container);
@@ -13495,7 +12287,7 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_VAR_HANDLER(ZEND_O
 isset_again:
                if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
                        str = Z_STR_P(offset);
-                       if (IS_VAR != IS_CONST) {
+                       if (IS_CV != IS_CONST) {
                                if (ZEND_HANDLE_NUMERIC(str, hval)) {
                                        goto num_index_prop;
                                }
@@ -13555,7 +12347,7 @@ num_index_prop:
 
                result = 0;
                if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
-                       if (IS_VAR == IS_CV || IS_VAR == IS_VAR) {
+                       if (IS_CV & (IS_CV|IS_VAR)) {
                                ZVAL_DEREF(offset);
                        }
                        if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
@@ -13581,28 +12373,27 @@ num_index_prop:
                result = ((opline->extended_value & ZEND_ISSET) == 0);
        }
 
-       zval_ptr_dtor_nogc(free_op2);
        ZVAL_BOOL(EX_VAR(opline->result.var), result);
        zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
        zval *container;
        int result;
        zval *offset;
 
        SAVE_OPLINE();
        container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+       offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
 
        if (IS_TMP_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
                if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
-                       result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+                       result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
                } else {
                        zend_error(E_NOTICE, "Trying to check property of non-object");
                        result = 0;
@@ -13614,53 +12405,13 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_TMP_VAR_HANDLER(ZEND_
                result = ((opline->extended_value & ZEND_ISSET) == 0);
        }
 
-       zval_ptr_dtor_nogc(free_op2);
-       ZVAL_BOOL(EX_VAR(opline->result.var), result);
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_INSTANCEOF_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *expr;
-       zend_bool result;
-
-       SAVE_OPLINE();
-       expr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
-       if (Z_TYPE_P(expr) == IS_OBJECT) {
-               zend_class_entry *ce;
-
-               if (IS_VAR == IS_CONST) {
-                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                       } else {
-                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, ZEND_FETCH_CLASS_NO_AUTOLOAD TSRMLS_CC);
-                               if (UNEXPECTED(ce == NULL)) {
-                                       ZVAL_FALSE(EX_VAR(opline->result.var));
-                                       zval_ptr_dtor_nogc(free_op1);
-                                       CHECK_EXCEPTION();
-                                       ZEND_VM_NEXT_OPCODE();
-                               }
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
-                       }
-               } else {
-                       ce = Z_CE_P(EX_VAR(opline->op2.var));
-               }
-               result = instanceof_function(Z_OBJCE_P(expr), ce TSRMLS_CC);
-       } else {
-               result = 0;
-       }
        ZVAL_BOOL(EX_VAR(opline->result.var), result);
        zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_YIELD_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_YIELD_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
@@ -13741,21 +12492,21 @@ static int ZEND_FASTCALL  ZEND_YIELD_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_AR
        }
 
        /* Set the new yielded key */
-       if (IS_VAR != IS_UNUSED) {
-               zend_free_op free_op2;
-               zval *key = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+       if (IS_CV != IS_UNUSED) {
+
+               zval *key = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
 
                /* Consts, temporary variables and references need copying */
-               if (IS_VAR == IS_CONST) {
+               if (IS_CV == IS_CONST) {
                        ZVAL_DUP(&generator->key, key);
-               } else if (IS_VAR == IS_TMP_VAR) {
+               } else if (IS_CV == IS_TMP_VAR) {
                        ZVAL_COPY_VALUE(&generator->key, key);
-               } else if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && Z_ISREF_P(key)) {
+               } else if ((IS_CV == IS_VAR || IS_CV == IS_CV) && Z_ISREF_P(key)) {
                        ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
-                       zval_ptr_dtor_nogc(free_op2);
+
                } else {
                        ZVAL_COPY_VALUE(&generator->key, key);
-                       if (IS_VAR == IS_CV) {
+                       if (IS_CV == IS_CV) {
                                if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
                        }
                }
@@ -13791,251 +12542,357 @@ static int ZEND_FASTCALL  ZEND_YIELD_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_AR
        ZEND_VM_RETURN();
 }
 
-static int ZEND_FASTCALL  ZEND_POW_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_POW_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
 
        SAVE_OPLINE();
        pow_function(EX_VAR(opline->result.var),
                _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
-       zval_ptr_dtor_nogc(free_op2);
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_TMP_UNUSED(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_TMP_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
-       zval *varname;
-       zval *retval;
-       zend_string *name;
-       HashTable *target_symbol_table;
+       zval *container;
+       zend_free_op free_op2;
+       zval *offset;
 
        SAVE_OPLINE();
-       varname = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+       container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+       offset  = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if (IS_TMP_VAR == IS_CONST) {
-               name = Z_STR_P(varname);
-       } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
-               name = Z_STR_P(varname);
-               zend_string_addref(name);
+       if ((IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               zend_error(E_NOTICE, "Trying to get property of non-object");
+               ZVAL_NULL(EX_VAR(opline->result.var));
        } else {
-               name = zval_get_string(varname);
-       }
+               zval *retval;
 
-       if (IS_UNUSED != IS_UNUSED) {
-               zend_class_entry *ce;
+               /* here we are sure we are dealing with an object */
+               do {
+                       if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
+                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
+                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
+                               zend_object *zobj = Z_OBJ_P(container);
 
-               if (IS_UNUSED == IS_CONST) {
-                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                       } else {
-                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                               if (UNEXPECTED(ce == NULL)) {
-                                       if (IS_TMP_VAR != IS_CONST) {
-                                               zend_string_release(name);
-                                       }
-                                       zval_ptr_dtor_nogc(free_op1);
-                                       CHECK_EXCEPTION();
-                                       ZEND_VM_NEXT_OPCODE();
-                               }
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
-                       }
-               } else {
-                       ce = Z_CE_P(EX_VAR(opline->op2.var));
-               }
-               retval = zend_std_get_static_property(ce, name, 0, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op1);
-       } else {
-               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-               retval = zend_hash_find(target_symbol_table, name);
-               if (retval == NULL) {
-                       switch (type) {
-                               case BP_VAR_R:
-                               case BP_VAR_UNSET:
-                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                       /* break missing intentionally */
-                               case BP_VAR_IS:
-                                       retval = &EG(uninitialized_zval);
-                                       break;
-                               case BP_VAR_RW:
-                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                       /* break missing intentionally */
-                               case BP_VAR_W:
-                                       retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
-                                       break;
-                               EMPTY_SWITCH_DEFAULT_CASE()
-                       }
-               /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
-               } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
-                       retval = Z_INDIRECT_P(retval);
-                       if (Z_TYPE_P(retval) == IS_UNDEF) {
-                               switch (type) {
-                                       case BP_VAR_R:
-                                       case BP_VAR_UNSET:
-                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                               /* break missing intentionally */
-                                       case BP_VAR_IS:
-                                               retval = &EG(uninitialized_zval);
+                               if (EXPECTED(prop_info)) {
+                                       retval = OBJ_PROP(zobj, prop_info->offset);
+                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
+                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
                                                break;
-                                       case BP_VAR_RW:
-                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                               /* break missing intentionally */
-                                       case BP_VAR_W:
-                                               ZVAL_NULL(retval);
+                                       }
+                               } else if (EXPECTED(zobj->properties != NULL)) {
+                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
+                                       if (EXPECTED(retval)) {
+                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
                                                break;
-                                       EMPTY_SWITCH_DEFAULT_CASE()
+                                       }
                                }
                        }
-               }
-               if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
-                       if (Z_CONSTANT_P(retval)) {
-                               zval_update_constant(retval, 1 TSRMLS_CC);
-                       }
-               } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
-                       zval_ptr_dtor_nogc(free_op1);
-               }
-       }
 
-       if (IS_TMP_VAR != IS_CONST) {
-               zend_string_release(name);
-       }
+                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
 
-       ZEND_ASSERT(retval != NULL);
-       if (type == BP_VAR_R || type == BP_VAR_IS) {
-               if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
-                       ZVAL_UNREF(retval);
-               }
-               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-       } else {
-               ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
+                       if (retval != EX_VAR(opline->result.var)) {
+                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                       }
+               } while (0);
        }
+
+       zval_ptr_dtor_nogc(free_op2);
+       zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_R_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_TMP_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_var_address_helper_SPEC_TMP_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *container;
+       zend_free_op free_op2;
+       zval *offset;
 
-static int ZEND_FASTCALL  ZEND_FETCH_W_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_TMP_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+       SAVE_OPLINE();
+       container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+       offset  = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-static int ZEND_FASTCALL  ZEND_FETCH_RW_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_TMP_UNUSED(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+       if ((IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               ZVAL_NULL(EX_VAR(opline->result.var));
+       } else {
+               zval *retval;
 
-static int ZEND_FASTCALL  ZEND_FETCH_FUNC_ARG_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+               /* here we are sure we are dealing with an object */
+               do {
+                       if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
+                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
+                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
+                               zend_object *zobj = Z_OBJ_P(container);
 
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-               return zend_fetch_var_address_helper_SPEC_TMP_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else {
-               return zend_fetch_var_address_helper_SPEC_TMP_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
+                               if (EXPECTED(prop_info)) {
+                                       retval = OBJ_PROP(zobj, prop_info->offset);
+                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
+                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                                               break;
+                                       }
+                               } else if (EXPECTED(zobj->properties != NULL)) {
+                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
+                                       if (EXPECTED(retval)) {
+                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                                               break;
+                                       }
+                               }
+                       }
 
-static int ZEND_FASTCALL  ZEND_FETCH_UNSET_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_TMP_UNUSED(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
 
-static int ZEND_FASTCALL  ZEND_FETCH_IS_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_TMP_UNUSED(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+                       if (retval != EX_VAR(opline->result.var)) {
+                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                       }
+               } while (0);
+       }
+
+       zval_ptr_dtor_nogc(free_op2);
+       zval_ptr_dtor_nogc(free_op1);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_TMP_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zval *container;
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
 
        if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+               /* Behave like FETCH_OBJ_W */
+               zend_free_op free_op1, free_op2;
+               zval *property;
+
+               SAVE_OPLINE();
+               property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+               container = NULL;
+
         if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
             zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
         }
-               container = NULL;
                if (IS_TMP_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
                }
-               ZVAL_DEREF(container);
-               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
+               zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_TMP_VAR, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+               zval_ptr_dtor_nogc(free_op2);
                if (IS_TMP_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
                        EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
                }
 
-
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
        } else {
-               if (IS_UNUSED == IS_UNUSED) {
-                       zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
-               }
-               container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
-
-               zval_ptr_dtor_nogc(free_op1);
+               return ZEND_FETCH_OBJ_R_SPEC_TMP_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ADD_VAR_SPEC_TMP_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
-       zval *expr_ptr, new_expr;
+       zend_free_op free_op2;
+       zval *str = EX_VAR(opline->result.var);
+       zval *var;
+       zval var_copy;
+       int use_copy = 0;
 
        SAVE_OPLINE();
-       if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) &&
-           (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
-               expr_ptr = NULL;
-               if (IS_TMP_VAR == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
-               }
-               ZVAL_MAKE_REF(expr_ptr);
-               Z_ADDREF_P(expr_ptr);
+       var = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       } else {
-               expr_ptr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-               if (IS_TMP_VAR == IS_TMP_VAR) {
-                       ZVAL_COPY_VALUE(&new_expr, expr_ptr);
-                       expr_ptr = &new_expr;
-               } else if (IS_TMP_VAR == IS_CONST) {
-                       if (!Z_IMMUTABLE_P(expr_ptr)) {
-                               ZVAL_DUP(&new_expr, expr_ptr);
-                               expr_ptr = &new_expr;
-                       }
-               } else if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) && Z_ISREF_P(expr_ptr)) {
-                       expr_ptr = Z_REFVAL_P(expr_ptr);
-                       if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
+       if (IS_TMP_VAR == IS_UNUSED) {
+               /* Initialize for erealloc in add_string_to_string */
+               ZVAL_EMPTY_STRING(str);
+       }
 
-               } else if (IS_TMP_VAR == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
-                       Z_ADDREF_P(expr_ptr);
+       if (Z_TYPE_P(var) != IS_STRING) {
+               use_copy = zend_make_printable_zval(var, &var_copy TSRMLS_CC);
+
+               if (use_copy) {
+                       var = &var_copy;
                }
        }
+       add_string_to_string(str, str, var);
 
-       if (IS_UNUSED != IS_UNUSED) {
+       if (use_copy) {
+               zend_string_release(Z_STR_P(var));
+       }
+       /* original comment, possibly problematic:
+        * FREE_OP is missing intentionally here - we're always working on the same temporary variable
+        * (Zeev):  I don't think it's problematic, we only use variables
+        * which aren't affected by FREE_OP(Ts, )'s anyway, unless they're
+        * string offsets or overloaded objects
+        */
+       zval_ptr_dtor_nogc(free_op2);
 
-               zval *offset = NULL;
-               zend_string *str;
-               zend_ulong hval;
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-add_again:
-               switch (Z_TYPE_P(offset)) {
-                       case IS_DOUBLE:
-                               hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                               goto num_index;
+static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_TMP_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zval *function_name;
+       zend_free_op free_op1, free_op2;
+       zval *object;
+       zend_function *fbc;
+       zend_class_entry *called_scope;
+       zend_object *obj;
+
+       SAVE_OPLINE();
+
+       function_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+
+       if ((IS_TMP_VAR|IS_VAR) != IS_CONST &&
+           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
+               if (UNEXPECTED(EG(exception) != NULL)) {
+                       HANDLE_EXCEPTION();
+               }
+               zend_error_noreturn(E_ERROR, "Method name must be a string");
+       }
+
+       object = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+
+       if (IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+               uint32_t nesting = 1;
+
+               if (UNEXPECTED(EG(exception) != NULL)) {
+                       zval_ptr_dtor_nogc(free_op2);
+                       HANDLE_EXCEPTION();
+               }
+
+               zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s",  Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
+               zval_ptr_dtor_nogc(free_op2);
+
+               if (EG(exception) != NULL) {
+                       HANDLE_EXCEPTION();
+               }
+
+               /* No exception raised: Skip over arguments until fcall opcode with correct
+                * nesting level. Return NULL (except when return value unused) */
+               do {
+                       opline++;
+                       if (opline->opcode == ZEND_INIT_FCALL ||
+                               opline->opcode == ZEND_INIT_FCALL_BY_NAME ||
+                               opline->opcode == ZEND_INIT_NS_FCALL_BY_NAME ||
+                               opline->opcode == ZEND_INIT_METHOD_CALL ||
+                               opline->opcode == ZEND_INIT_STATIC_METHOD_CALL ||
+                               opline->opcode == ZEND_INIT_USER_CALL ||
+                               opline->opcode == ZEND_NEW
+                       ) {
+                               nesting++;
+                       } else if (opline->opcode == ZEND_DO_FCALL) {
+                               nesting--;
+                       }
+               } while (nesting);
+
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
+
+               /* We've skipped EXT_FCALL_BEGIND, so also skip the ending opcode */
+               if ((opline + 1)->opcode == ZEND_EXT_FCALL_END) {
+                       opline++;
+               }
+               ZEND_VM_JMP(++opline);
+       }
+
+       obj = Z_OBJ_P(object);
+       called_scope = obj->ce;
+
+       if ((IS_TMP_VAR|IS_VAR) != IS_CONST ||
+           EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
+           zend_object *orig_obj = obj;
+
+               if (UNEXPECTED(obj->handlers->get_method == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Object does not support method calls");
+               }
+
+               /* First, locate the function. */
+               fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
+               if (UNEXPECTED(fbc == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
+               }
+               if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
+                   EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
+                   EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
+                   EXPECTED(obj == orig_obj)) {
+                       CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope, fbc);
+               }
+       }
+
+       if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_STATIC) != 0)) {
+               obj = NULL;
+       } else {
+               GC_REFCOUNT(obj)++; /* For $this pointer */
+       }
+
+       EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
+               fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
+
+       zval_ptr_dtor_nogc(free_op2);
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *expr_ptr, new_expr;
+
+       SAVE_OPLINE();
+       if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) &&
+           (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
+               expr_ptr = NULL;
+               if (IS_TMP_VAR == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
+               }
+               ZVAL_MAKE_REF(expr_ptr);
+               Z_ADDREF_P(expr_ptr);
+
+       } else {
+               expr_ptr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+               if (IS_TMP_VAR == IS_TMP_VAR) {
+                       ZVAL_COPY_VALUE(&new_expr, expr_ptr);
+                       expr_ptr = &new_expr;
+               } else if (IS_TMP_VAR == IS_CONST) {
+                       if (!Z_IMMUTABLE_P(expr_ptr)) {
+                               ZVAL_DUP(&new_expr, expr_ptr);
+                               expr_ptr = &new_expr;
+                       }
+               } else if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) && Z_ISREF_P(expr_ptr)) {
+                       expr_ptr = Z_REFVAL_P(expr_ptr);
+                       if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
+
+               } else if (IS_TMP_VAR == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
+                       Z_ADDREF_P(expr_ptr);
+               }
+       }
+
+       if ((IS_TMP_VAR|IS_VAR) != IS_UNUSED) {
+               zend_free_op free_op2;
+               zval *offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+               zend_string *str;
+               zend_ulong hval;
+
+add_again:
+               switch (Z_TYPE_P(offset)) {
+                       case IS_DOUBLE:
+                               hval = zend_dval_to_lval(Z_DVAL_P(offset));
+                               goto num_index;
                        case IS_LONG:
                                hval = Z_LVAL_P(offset);
 num_index:
@@ -14043,7 +12900,7 @@ num_index:
                                break;
                        case IS_STRING:
                                str = Z_STR_P(offset);
-                               if (IS_UNUSED != IS_CONST) {
+                               if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
                                        if (ZEND_HANDLE_NUMERIC(str, hval)) {
                                                goto num_index;
                                        }
@@ -14070,7 +12927,7 @@ str_index:
                                /* do nothing */
                                break;
                }
-
+               zval_ptr_dtor_nogc(free_op2);
        } else {
                zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
        }
@@ -14078,7 +12935,7 @@ str_index:
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_TMP_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        zval *array;
        uint32_t size;
@@ -14104,5434 +12961,1871 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HA
                ZEND_VM_NEXT_OPCODE();
 #if 0 || IS_TMP_VAR != IS_UNUSED
        } else {
-               return ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 #endif
        }
 }
 
-static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval tmp, *varname;
-       HashTable *target_symbol_table;
-       zend_free_op free_op1;
+       zend_free_op free_op1, free_op2;
+       zval *container;
+       int result;
+       zend_ulong hval;
+       zval *offset;
 
        SAVE_OPLINE();
-       if (IS_TMP_VAR == IS_CV &&
-           IS_UNUSED == IS_UNUSED &&
-           (opline->extended_value & ZEND_QUICK_SET)) {
-               zval *var = EX_VAR(opline->op1.var);
-
-               if (Z_REFCOUNTED_P(var)) {
-                       zend_refcounted *garbage = Z_COUNTED_P(var);
-
-                       if (!--GC_REFCOUNT(garbage)) {
-                               ZVAL_UNDEF(var);
-                               _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
-                       } else {
-                               GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
-                               ZVAL_UNDEF(var);
-                       }
-               } else {
-                       ZVAL_UNDEF(var);
-               }
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
-
-       varname = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
-       ZVAL_UNDEF(&tmp);
-       if (IS_TMP_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-               ZVAL_STR(&tmp, zval_get_string(varname));
-               varname = &tmp;
-       }
+       container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if (IS_UNUSED != IS_UNUSED) {
-               zend_class_entry *ce;
+       if (IS_TMP_VAR != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
+               HashTable *ht = Z_ARRVAL_P(container);
+               zval *value;
+               zend_string *str;
 
-               if (IS_UNUSED == IS_CONST) {
-                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                       } else {
-                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                               if (UNEXPECTED(EG(exception) != NULL)) {
-                                       if (IS_TMP_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-                                               zend_string_release(Z_STR(tmp));
-                                       }
-                                       zval_ptr_dtor_nogc(free_op1);
-                                       HANDLE_EXCEPTION();
-                               }
-                               if (UNEXPECTED(ce == NULL)) {
-                                       zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
+isset_again:
+               if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
+                       str = Z_STR_P(offset);
+                       if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+                               if (ZEND_HANDLE_NUMERIC(str, hval)) {
+                                       goto num_index_prop;
                                }
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
                        }
+str_index_prop:
+                       value = zend_hash_find_ind(ht, str);
+               } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
+                       hval = Z_LVAL_P(offset);
+num_index_prop:
+                       value = zend_hash_index_find(ht, hval);
                } else {
-                       ce = Z_CE_P(EX_VAR(opline->op2.var));
+                       switch (Z_TYPE_P(offset)) {
+                               case IS_DOUBLE:
+                                       hval = zend_dval_to_lval(Z_DVAL_P(offset));
+                                       goto num_index_prop;
+                               case IS_NULL:
+                                       str = STR_EMPTY_ALLOC();
+                                       goto str_index_prop;
+                               case IS_FALSE:
+                                       hval = 0;
+                                       goto num_index_prop;
+                               case IS_TRUE:
+                                       hval = 1;
+                                       goto num_index_prop;
+                               case IS_RESOURCE:
+                                       hval = Z_RES_HANDLE_P(offset);
+                                       goto num_index_prop;
+                               case IS_REFERENCE:
+                                       offset = Z_REFVAL_P(offset);
+                                       goto isset_again;
+                               default:
+                                       zend_error(E_WARNING, "Illegal offset type in isset or empty");
+                                       value = NULL;
+                                       break;
+                       }
                }
-               zend_std_unset_static_property(ce, Z_STR_P(varname), ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
-       } else {
-               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-               zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
-       }
-
-       if (IS_TMP_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-               zend_string_release(Z_STR(tmp));
-       }
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *value;
 
-       SAVE_OPLINE();
-       if (IS_TMP_VAR == IS_CV &&
-           IS_UNUSED == IS_UNUSED &&
-           (opline->extended_value & ZEND_QUICK_SET)) {
-               value = EX_VAR(opline->op1.var);
                if (opline->extended_value & ZEND_ISSET) {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+                       /* > IS_NULL means not IS_UNDEF and not IS_NULL */
+                       result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
+                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
                } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               !i_zend_is_true(value TSRMLS_CC));
-                       CHECK_EXCEPTION();
-               }
-               ZEND_VM_NEXT_OPCODE();
-       } else {
-               zend_free_op free_op1;
-               zval tmp, *varname = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
-               ZVAL_UNDEF(&tmp);
-               if (IS_TMP_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-                       ZVAL_STR(&tmp, zval_get_string(varname));
-                       varname = &tmp;
+                       result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
                }
-
-               if (IS_UNUSED != IS_UNUSED) {
-                       zend_class_entry *ce;
-
-                       if (IS_UNUSED == IS_CONST) {
-                               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                                       ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                               } else {
-                                       ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                                       if (UNEXPECTED(ce == NULL)) {
-                                               CHECK_EXCEPTION();
-                                               ZEND_VM_NEXT_OPCODE();
-                                       }
-                                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
-                               }
-                       } else {
-                               ce = Z_CE_P(EX_VAR(opline->op2.var));
-                       }
-                       value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+       } else if (IS_TMP_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+               if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
+                       result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
                } else {
-                       HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-                       value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
-               }
-
-               if (IS_TMP_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-                       zend_string_release(Z_STR(tmp));
+                       zend_error(E_NOTICE, "Trying to check element of non-array");
+                       result = 0;
                }
-               zval_ptr_dtor_nogc(free_op1);
-
-               if (opline->extended_value & ZEND_ISSET) {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               value && Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               !value || !i_zend_is_true(value TSRMLS_CC));
+               if ((opline->extended_value & ZEND_ISSET) == 0) {
+                       result = !result;
                }
+       } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
+               zval tmp;
 
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_YIELD_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       /* The generator object is stored in EX(return_value) */
-       zend_generator *generator = (zend_generator *) EX(return_value);
-
-       if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
-               zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
-       }
-
-       /* Destroy the previously yielded value */
-       zval_ptr_dtor(&generator->value);
-
-       /* Destroy the previously yielded key */
-       zval_ptr_dtor(&generator->key);
-
-       /* Set the new yielded value */
-       if (IS_TMP_VAR != IS_UNUSED) {
-               zend_free_op free_op1;
-
-               if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
-                       /* Constants and temporary variables aren't yieldable by reference,
-                        * but we still allow them with a notice. */
-                       if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
-                               zval *value;
-
-                               zend_error(E_NOTICE, "Only variable references should be yielded by reference");
-
-                               value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-                               ZVAL_COPY_VALUE(&generator->value, value);
-                               if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
-
-                               /* Temporary variables don't need ctor copying */
-                               if (IS_TMP_VAR != IS_TMP_VAR) {
-                                       zval_opt_copy_ctor(&generator->value);
-                               }
-                       } else {
-                               zval *value_ptr = NULL;
-
-                               if (IS_TMP_VAR == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
-                                       zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
-                               }
-
-                               /* If a function call result is yielded and the function did
-                                * not return by reference we throw a notice. */
-                               if (IS_TMP_VAR == IS_VAR &&
-                                   (value_ptr == &EG(uninitialized_zval) ||
-                                    (opline->extended_value == ZEND_RETURNS_FUNCTION &&
-                                     !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
-                                       zend_error(E_NOTICE, "Only variable references should be yielded by reference");
-                               } else {
-                                       ZVAL_MAKE_REF(value_ptr);
-                               }
-                               ZVAL_COPY(&generator->value, value_ptr);
-
+               result = 0;
+               if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
+                       if ((IS_TMP_VAR|IS_VAR) & (IS_CV|IS_VAR)) {
+                               ZVAL_DEREF(offset);
                        }
-               } else {
-                       zval *value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
-                       /* Consts, temporary variables and references need copying */
-                       if (IS_TMP_VAR == IS_CONST) {
-                               ZVAL_DUP(&generator->value, value);
-                       } else if (IS_TMP_VAR == IS_TMP_VAR) {
-                               ZVAL_COPY_VALUE(&generator->value, value);
-            } else if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) && Z_ISREF_P(value)) {
-                               ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
-
-                       } else {
-                               ZVAL_COPY_VALUE(&generator->value, value);
-                               if (IS_TMP_VAR == IS_CV) {
-                                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+                       if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
+                                       || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
+                                               && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
+                               ZVAL_DUP(&tmp, offset);
+                               convert_to_long(&tmp);
+                               offset = &tmp;
+                       }
+               }
+               if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
+                       if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
+                               if ((opline->extended_value & ZEND_ISSET) ||
+                                   Z_STRVAL_P(container)[offset->value.lval] != '0') {
+                                       result = 1;
                                }
                        }
                }
+               if ((opline->extended_value & ZEND_ISSET) == 0) {
+                       result = !result;
+               }
        } else {
-               /* If no value was specified yield null */
-               ZVAL_NULL(&generator->value);
+               result = ((opline->extended_value & ZEND_ISSET) == 0);
        }
 
-       /* Set the new yielded key */
-       if (IS_UNUSED != IS_UNUSED) {
+       zval_ptr_dtor_nogc(free_op2);
+       ZVAL_BOOL(EX_VAR(opline->result.var), result);
+       zval_ptr_dtor_nogc(free_op1);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-               zval *key = NULL;
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_TMP_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1, free_op2;
+       zval *container;
+       int result;
+       zval *offset;
 
-               /* Consts, temporary variables and references need copying */
-               if (IS_UNUSED == IS_CONST) {
-                       ZVAL_DUP(&generator->key, key);
-               } else if (IS_UNUSED == IS_TMP_VAR) {
-                       ZVAL_COPY_VALUE(&generator->key, key);
-               } else if ((IS_UNUSED == IS_VAR || IS_UNUSED == IS_CV) && Z_ISREF_P(key)) {
-                       ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
+       SAVE_OPLINE();
+       container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
+       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
+       if (IS_TMP_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+               if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
+                       result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
                } else {
-                       ZVAL_COPY_VALUE(&generator->key, key);
-                       if (IS_UNUSED == IS_CV) {
-                               if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
-                       }
+                       zend_error(E_NOTICE, "Trying to check property of non-object");
+                       result = 0;
                }
-
-               if (Z_TYPE(generator->key) == IS_LONG
-                   && Z_LVAL(generator->key) > generator->largest_used_integer_key
-               ) {
-                       generator->largest_used_integer_key = Z_LVAL(generator->key);
+               if ((opline->extended_value & ZEND_ISSET) == 0) {
+                       result = !result;
                }
        } else {
-               /* If no key was specified we use auto-increment keys */
-               generator->largest_used_integer_key++;
-               ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
-       }
-
-       if (RETURN_VALUE_USED(opline)) {
-               /* If the return value of yield is used set the send
-                * target and initialize it to NULL */
-               generator->send_target = EX_VAR(opline->result.var);
-               ZVAL_NULL(generator->send_target);
-       } else {
-               generator->send_target = NULL;
+               result = ((opline->extended_value & ZEND_ISSET) == 0);
        }
 
-       /* We increment to the next op, so we are at the correct position when the
-        * generator is resumed. */
-       ZEND_VM_INC_OPCODE();
-
-       /* The GOTO VM uses a local opline variable. We need to set the opline
-        * variable in execute_data so we don't resume at an old position. */
-       SAVE_OPLINE();
-
-       ZEND_VM_RETURN();
+       zval_ptr_dtor_nogc(free_op2);
+       ZVAL_BOOL(EX_VAR(opline->result.var), result);
+       zval_ptr_dtor_nogc(free_op1);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_MOD_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BW_NOT_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
 
        SAVE_OPLINE();
-       fast_mod_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+       bitwise_not_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
-
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_SL_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BOOL_NOT_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
 
        SAVE_OPLINE();
-       shift_left_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+       boolean_not_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
-
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_SR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_PRE_INC_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
+       zval *var_ptr;
 
        SAVE_OPLINE();
-       shift_right_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
+       var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+       if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
+       }
 
-static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
+       if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
+               fast_increment_function(var_ptr);
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
+               }
+               ZEND_VM_NEXT_OPCODE();
+       }
 
-       SAVE_OPLINE();
-       concat_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
+       if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
+       }
+
+       ZVAL_DEREF(var_ptr);
+       SEPARATE_ZVAL_NOREF(var_ptr);
+
+       increment_function(var_ptr);
 
+       if (RETURN_VALUE_USED(opline)) {
+               ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+       }
+
+       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_PRE_DEC_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
+       zval *var_ptr;
 
        SAVE_OPLINE();
-       fast_is_identical_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
+       var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
+       }
+
+       if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
+               fast_decrement_function(var_ptr);
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
+               }
+               ZEND_VM_NEXT_OPCODE();
+       }
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
+       }
+
+       ZVAL_DEREF(var_ptr);
+       SEPARATE_ZVAL_NOREF(var_ptr);
+
+       decrement_function(var_ptr);
+
+       if (RETURN_VALUE_USED(opline)) {
+               ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+       }
 
+       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_POST_INC_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
-       zval *result = EX_VAR(opline->result.var);
+       zval *var_ptr;
 
        SAVE_OPLINE();
-       fast_is_not_identical_function(result,
-               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
+       var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
+       }
+
+       if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
+               ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
+               fast_increment_function(var_ptr);
+               ZEND_VM_NEXT_OPCODE();
+       }
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+               ZVAL_NULL(EX_VAR(opline->result.var));
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
+       }
+
+       ZVAL_DEREF(var_ptr);
+       ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
+       zval_opt_copy_ctor(var_ptr);
 
+       increment_function(var_ptr);
+
+       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_POST_DEC_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
+       zval *var_ptr;
 
        SAVE_OPLINE();
-       bitwise_or_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
+       var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
+       }
+
+       if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
+               ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
+               fast_decrement_function(var_ptr);
+               ZEND_VM_NEXT_OPCODE();
+       }
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+               ZVAL_NULL(EX_VAR(opline->result.var));
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
+       }
+
+       ZVAL_DEREF(var_ptr);
+       ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
+       zval_opt_copy_ctor(var_ptr);
+
+       decrement_function(var_ptr);
 
+       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ECHO_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
+       zval *z;
 
        SAVE_OPLINE();
-       bitwise_and_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
+       z = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
+
+       zend_print_variable(z TSRMLS_CC);
 
+       zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_PRINT_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
 
-       SAVE_OPLINE();
-       bitwise_xor_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       ZVAL_LONG(EX_VAR(opline->result.var), 1);
+       return ZEND_ECHO_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_JMPZ_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
+       zval *val;
 
        SAVE_OPLINE();
-       boolean_xor_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
+       val = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       if (IS_VAR == IS_TMP_VAR) {
+               if (Z_TYPE_P(val) == IS_TRUE) {
+                       ZEND_VM_SET_OPCODE(opline + 1);
+                       ZEND_VM_CONTINUE();
+               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+                       ZEND_VM_CONTINUE();
+               }
+       }
+
+       if (i_zend_is_true(val TSRMLS_CC)) {
+               opline++;
+       } else {
+               opline = opline->op2.jmp_addr;
+       }
+       zval_ptr_dtor_nogc(free_op1);
+       if (UNEXPECTED(EG(exception) != NULL)) {
+               HANDLE_EXCEPTION();
+       }
+       ZEND_VM_JMP(opline);
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_JMPNZ_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
-       zval *container;
+       zval *val;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-       zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
+       val = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
+
+       if (IS_VAR == IS_TMP_VAR) {
+               if (Z_TYPE_P(val) == IS_TRUE) {
+                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+                       ZEND_VM_CONTINUE();
+               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+                       ZEND_VM_SET_OPCODE(opline + 1);
+                       ZEND_VM_CONTINUE();
+               }
+       }
 
+       if (i_zend_is_true(val TSRMLS_CC)) {
+               opline = opline->op2.jmp_addr;
+       } else {
+               opline++;
+       }
        zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       if (UNEXPECTED(EG(exception) != NULL)) {
+               HANDLE_EXCEPTION();
+       }
+       ZEND_VM_JMP(opline);
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_JMPZNZ_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
-       zval *container;
+       zval *val;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-       zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
+       val = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
+
+       if (IS_VAR == IS_TMP_VAR) {
+               if (EXPECTED(Z_TYPE_P(val) == IS_TRUE)) {
+                       ZEND_VM_SET_RELATIVE_OPCODE(opline, opline->extended_value);
+                       ZEND_VM_CONTINUE();
+               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+                       ZEND_VM_CONTINUE();
+               }
+       }
 
+       if (i_zend_is_true(val TSRMLS_CC)) {
+               opline = (zend_op*)(((char*)opline) + opline->extended_value);
+       } else {
+               opline = opline->op2.jmp_addr;
+       }
        zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       if (UNEXPECTED(EG(exception) != NULL)) {
+               HANDLE_EXCEPTION();
+       }
+       ZEND_VM_JMP(opline);
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_JMPZ_EX_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *container;
        zend_free_op free_op1;
+       zval *val;
 
        SAVE_OPLINE();
+       val = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
 
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-        if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
-            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
-        }
-               container = NULL;
-               if (IS_TMP_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-               }
-               ZVAL_DEREF(container);
-               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
-               if (IS_TMP_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
-                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+       if (IS_VAR == IS_TMP_VAR) {
+               if (Z_TYPE_P(val) == IS_TRUE) {
+                       ZVAL_TRUE(EX_VAR(opline->result.var));
+                       ZEND_VM_SET_OPCODE(opline + 1);
+                       ZEND_VM_CONTINUE();
+               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+                       ZVAL_FALSE(EX_VAR(opline->result.var));
+                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+                       ZEND_VM_CONTINUE();
                }
+       }
 
-
+       if (i_zend_is_true(val TSRMLS_CC)) {
+               zval_ptr_dtor_nogc(free_op1);
+               ZVAL_TRUE(EX_VAR(opline->result.var));
+               opline++;
        } else {
-               if (IS_CV == IS_UNUSED) {
-                       zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
-               }
-               container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
-
                zval_ptr_dtor_nogc(free_op1);
+               ZVAL_FALSE(EX_VAR(opline->result.var));
+               opline = opline->op2.jmp_addr;
        }
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       if (UNEXPECTED(EG(exception) != NULL)) {
+               HANDLE_EXCEPTION();
+       }
+       ZEND_VM_JMP(opline);
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_JMPNZ_EX_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
-       zval *container;
-
-       zval *offset;
+       zval *val;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-       offset  = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+       val = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
 
-       if ((IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
-           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
-               zend_error(E_NOTICE, "Trying to get property of non-object");
-               ZVAL_NULL(EX_VAR(opline->result.var));
+       if (IS_VAR == IS_TMP_VAR) {
+               if (Z_TYPE_P(val) == IS_TRUE) {
+                       ZVAL_TRUE(EX_VAR(opline->result.var));
+                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+                       ZEND_VM_CONTINUE();
+               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+                       ZVAL_FALSE(EX_VAR(opline->result.var));
+                       ZEND_VM_SET_OPCODE(opline + 1);
+                       ZEND_VM_CONTINUE();
+               }
+       }
+       if (i_zend_is_true(val TSRMLS_CC)) {
+               ZVAL_TRUE(EX_VAR(opline->result.var));
+               opline = opline->op2.jmp_addr;
        } else {
-               zval *retval;
-
-               /* here we are sure we are dealing with an object */
-               do {
-                       if (IS_CV == IS_CONST &&
-                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
-                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
-                               zend_object *zobj = Z_OBJ_P(container);
-
-                               if (EXPECTED(prop_info)) {
-                                       retval = OBJ_PROP(zobj, prop_info->offset);
-                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               } else if (EXPECTED(zobj->properties != NULL)) {
-                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
-                                       if (EXPECTED(retval)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               }
-                       }
-
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
-
-                       if (retval != EX_VAR(opline->result.var)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                       }
-               } while (0);
+               ZVAL_FALSE(EX_VAR(opline->result.var));
+               opline++;
        }
-
        zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       if (UNEXPECTED(EG(exception) != NULL)) {
+               HANDLE_EXCEPTION();
+       }
+       ZEND_VM_JMP(opline);
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_RETURN_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zval *retval_ptr;
        zend_free_op free_op1;
-       zval *container;
-
-       zval *offset;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-       offset  = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+       retval_ptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
 
-       if ((IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
-           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
-               ZVAL_NULL(EX_VAR(opline->result.var));
+       if (!EX(return_value)) {
+               zval_ptr_dtor_nogc(free_op1);
        } else {
-               zval *retval;
-
-               /* here we are sure we are dealing with an object */
-               do {
-                       if (IS_CV == IS_CONST &&
-                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
-                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
-                               zend_object *zobj = Z_OBJ_P(container);
-
-                               if (EXPECTED(prop_info)) {
-                                       retval = OBJ_PROP(zobj, prop_info->offset);
-                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               } else if (EXPECTED(zobj->properties != NULL)) {
-                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
-                                       if (EXPECTED(retval)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
+               if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
+                       ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
+                       if (IS_VAR == IS_CONST) {
+                               if (UNEXPECTED(Z_OPT_COPYABLE_P(EX(return_value)))) {
+                                       zval_copy_ctor_func(EX(return_value));
                                }
                        }
-
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
-
-                       if (retval != EX_VAR(opline->result.var)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+               } else if ((IS_VAR == IS_CV || IS_VAR == IS_VAR) && Z_ISREF_P(retval_ptr)) {
+                       ZVAL_COPY(EX(return_value), Z_REFVAL_P(retval_ptr));
+                       zval_ptr_dtor_nogc(free_op1);
+               } else {
+                       ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
+                       if (IS_VAR == IS_CV) {
+                               if (Z_OPT_REFCOUNTED_P(retval_ptr)) Z_ADDREF_P(retval_ptr);
                        }
-               } while (0);
+               }
        }
-
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_RETURN_BY_REF_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *container;
+       zval *retval_ptr;
+       zend_free_op free_op1;
 
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-               /* Behave like FETCH_OBJ_W */
-               zend_free_op free_op1;
-               zval *property;
+       SAVE_OPLINE();
 
-               SAVE_OPLINE();
-               property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
-               container = NULL;
+       do {
+               if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR ||
+                   (IS_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_VALUE)) {
+                       /* Not supposed to happen, but we'll allow it */
+                       zend_error(E_NOTICE, "Only variable references should be returned by reference");
 
-        if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
-            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
-        }
-               if (IS_TMP_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+                       retval_ptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+                       if (!EX(return_value)) {
+                               if (IS_VAR == IS_TMP_VAR) {
+                                       zval_ptr_dtor_nogc(free_op1);
+                               }
+                       } else {
+                               ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
+                               Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
+                               if (IS_VAR != IS_TMP_VAR) {
+                                       zval_opt_copy_ctor_no_imm(EX(return_value));
+                               }
+                       }
+                       break;
                }
-               zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_TMP_VAR, property, IS_CV, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
 
-               if (IS_TMP_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
-                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+               retval_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+
+               if (IS_VAR == IS_VAR && UNEXPECTED(retval_ptr == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot return string offsets by reference");
                }
 
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       } else {
-               return ZEND_FETCH_OBJ_R_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
+               if (IS_VAR == IS_VAR) {
+                       if (retval_ptr == &EG(uninitialized_zval) ||
+                           (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+                            !(Z_VAR_FLAGS_P(retval_ptr) & IS_VAR_RET_REF))) {
+                               zend_error(E_NOTICE, "Only variable references should be returned by reference");
+                               if (EX(return_value)) {
+                                       ZVAL_NEW_REF(EX(return_value), retval_ptr);
+                                       Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
+                                       if (Z_REFCOUNTED_P(retval_ptr)) Z_ADDREF_P(retval_ptr);
+                               }
+                               break;
+                       }
+               }
+
+               if (EX(return_value)) {
+                       ZVAL_MAKE_REF(retval_ptr);
+                       Z_ADDREF_P(retval_ptr);
+                       ZVAL_REF(EX(return_value), Z_REF_P(retval_ptr));
+                       Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
+               }
+       } while (0);
+
+       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+       return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_ADD_VAR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_THROW_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
-       zval *str = EX_VAR(opline->result.var);
-       zval *var;
-       zval var_copy;
-       int use_copy = 0;
+       zval *value;
+       zend_free_op free_op1;
 
        SAVE_OPLINE();
-       var = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+       value = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
 
-       if (IS_TMP_VAR == IS_UNUSED) {
-               /* Initialize for erealloc in add_string_to_string */
-               ZVAL_EMPTY_STRING(str);
+       if (IS_VAR == IS_CONST || UNEXPECTED(Z_TYPE_P(value) != IS_OBJECT)) {
+               if (UNEXPECTED(EG(exception) != NULL)) {
+                       HANDLE_EXCEPTION();
+               }
+               zend_error_noreturn(E_ERROR, "Can only throw objects");
        }
 
-       if (Z_TYPE_P(var) != IS_STRING) {
-               if (IS_CV != IS_TMP_VAR) {
-                       ZVAL_DEREF(var);
-               }
-               if (Z_TYPE_P(var) != IS_STRING) {
-                       use_copy = zend_make_printable_zval(var, &var_copy TSRMLS_CC);
-
-                       if (use_copy) {
-                               var = &var_copy;
-                       }
-               }
+       zend_exception_save(TSRMLS_C);
+       if (IS_VAR != IS_TMP_VAR) {
+               if (Z_REFCOUNTED_P(value)) Z_ADDREF_P(value);
        }
-       add_string_to_string(str, str, var);
 
-       if (use_copy) {
-               zend_string_release(Z_STR_P(var));
-       }
-       /* original comment, possibly problematic:
-        * FREE_OP is missing intentionally here - we're always working on the same temporary variable
-        * (Zeev):  I don't think it's problematic, we only use variables
-        * which aren't affected by FREE_OP(Ts, )'s anyway, unless they're
-        * string offsets or overloaded objects
-        */
+       zend_throw_exception_object(value TSRMLS_CC);
+       zend_exception_restore(TSRMLS_C);
+       zval_ptr_dtor_nogc(free_op1);
+       HANDLE_EXCEPTION();
+}
 
-       CHECK_EXCEPTION();
+static int ZEND_FASTCALL  ZEND_SEND_VAR_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zval *varptr, *arg;
+       zend_free_op free_op1;
+
+       varptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+       arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
+       ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
+       if (Z_ISREF_P(varptr)) {
+               ZVAL_COPY(arg, Z_REFVAL_P(varptr));
+               zval_ptr_dtor_nogc(free_op1);
+       } else {
+               ZVAL_COPY_VALUE(arg, varptr);
+               if (IS_VAR == IS_CV) {
+                       if (Z_OPT_REFCOUNTED_P(arg)) Z_ADDREF_P(arg);
+               }
+       }
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SEND_VAR_NO_REF_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *function_name;
        zend_free_op free_op1;
-       zval *object;
-       zend_function *fbc;
-       zend_class_entry *called_scope;
-       zend_object *obj;
+       zval *varptr, *arg;
 
        SAVE_OPLINE();
 
-       function_name = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
-
-       if (IS_CV != IS_CONST &&
-           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       HANDLE_EXCEPTION();
+       if (!(opline->extended_value & ZEND_ARG_COMPILE_TIME_BOUND)) {
+               if (!ARG_SHOULD_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
+                       return ZEND_SEND_VAR_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                }
-               zend_error_noreturn(E_ERROR, "Method name must be a string");
        }
 
-       object = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_TMP_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
-               uint32_t nesting = 1;
-
-               if (UNEXPECTED(EG(exception) != NULL)) {
+       varptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+       if ((!(opline->extended_value & ZEND_ARG_SEND_FUNCTION) ||
+            (Z_VAR_FLAGS_P(varptr) & IS_VAR_RET_REF)) &&
+           (Z_ISREF_P(varptr) || Z_TYPE_P(varptr) == IS_OBJECT)) {
 
-                       HANDLE_EXCEPTION();
+               ZVAL_MAKE_REF(varptr);
+               if (IS_VAR == IS_CV) {
+                       Z_ADDREF_P(varptr);
                }
-
-               zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s",  Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
-
-
-               if (EG(exception) != NULL) {
-                       HANDLE_EXCEPTION();
+       } else {
+               if ((opline->extended_value & ZEND_ARG_COMPILE_TIME_BOUND) ?
+                       !(opline->extended_value & ZEND_ARG_SEND_SILENT) :
+                       !ARG_MAY_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
+                       zend_error(E_STRICT, "Only variables should be passed by reference");
                }
+       }
 
-               /* No exception raised: Skip over arguments until fcall opcode with correct
-                * nesting level. Return NULL (except when return value unused) */
-               do {
-                       opline++;
-                       if (opline->opcode == ZEND_INIT_FCALL ||
-                               opline->opcode == ZEND_INIT_FCALL_BY_NAME ||
-                               opline->opcode == ZEND_INIT_NS_FCALL_BY_NAME ||
-                               opline->opcode == ZEND_INIT_METHOD_CALL ||
-                               opline->opcode == ZEND_INIT_STATIC_METHOD_CALL ||
-                               opline->opcode == ZEND_INIT_USER_CALL ||
-                               opline->opcode == ZEND_NEW
-                       ) {
-                               nesting++;
-                       } else if (opline->opcode == ZEND_DO_FCALL) {
-                               nesting--;
-                       }
-               } while (nesting);
-
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
-               }
+       arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
+       ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
+       ZVAL_COPY_VALUE(arg, varptr);
 
-               /* We've skipped EXT_FCALL_BEGIND, so also skip the ending opcode */
-               if ((opline + 1)->opcode == ZEND_EXT_FCALL_END) {
-                       opline++;
-               }
-               ZEND_VM_JMP(++opline);
-       }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       obj = Z_OBJ_P(object);
-       called_scope = obj->ce;
+static int ZEND_FASTCALL  ZEND_SEND_REF_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *varptr, *arg;
 
-       if (IS_CV != IS_CONST ||
-           EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
-           zend_object *orig_obj = obj;
+       SAVE_OPLINE();
+       varptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
 
-               if (UNEXPECTED(obj->handlers->get_method == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Object does not support method calls");
-               }
+       if (IS_VAR == IS_VAR && UNEXPECTED(varptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Only variables can be passed by reference");
+       }
 
-               /* First, locate the function. */
-               fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_CV == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
-               if (UNEXPECTED(fbc == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
-               }
-               if (IS_CV == IS_CONST &&
-                   EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
-                   EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
-                   EXPECTED(obj == orig_obj)) {
-                       CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope, fbc);
-               }
+       arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
+       ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
+       if (IS_VAR == IS_VAR && UNEXPECTED(varptr == &EG(error_zval))) {
+               ZVAL_NEW_REF(arg, &EG(uninitialized_zval));
+               ZEND_VM_NEXT_OPCODE();
        }
 
-       if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_STATIC) != 0)) {
-               obj = NULL;
+       if (Z_ISREF_P(varptr)) {
+               Z_ADDREF_P(varptr);
+               ZVAL_COPY_VALUE(arg, varptr);
+       } else if (IS_VAR == IS_VAR &&
+               UNEXPECTED(Z_TYPE_P(EX_VAR(opline->op1.var)) != IS_INDIRECT)) {
+               ZVAL_NEW_REF(arg, varptr);
        } else {
-               GC_REFCOUNT(obj)++; /* For $this pointer */
+               ZVAL_NEW_REF(arg, varptr);
+               Z_ADDREF_P(arg);
+               ZVAL_REF(varptr, Z_REF_P(arg));
        }
 
-       EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
-               fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
-
-
-       CHECK_EXCEPTION();
+       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_CASE_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SEND_VAR_EX_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zval *varptr, *arg;
        zend_free_op free_op1;
-       zval *result = EX_VAR(opline->result.var);
-
-       SAVE_OPLINE();
-       fast_equal_function(result,
-                _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-                _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
-       CHECK_EXCEPTION();
+       if (ARG_SHOULD_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
+               return ZEND_SEND_REF_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+       varptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+       arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
+       ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
+       if (Z_ISREF_P(varptr)) {
+               ZVAL_COPY(arg, Z_REFVAL_P(varptr));
+               zval_ptr_dtor_nogc(free_op1);
+       } else {
+               ZVAL_COPY_VALUE(arg, varptr);
+               if (IS_VAR == IS_CV) {
+                       if (Z_OPT_REFCOUNTED_P(arg)) Z_ADDREF_P(arg);
+               }
+       }
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SEND_USER_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zval *arg, *param, tmp;
        zend_free_op free_op1;
-       zval *expr_ptr, new_expr;
-
-       SAVE_OPLINE();
-       if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) &&
-           (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
-               expr_ptr = NULL;
-               if (IS_TMP_VAR == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
-               }
-               ZVAL_MAKE_REF(expr_ptr);
-               Z_ADDREF_P(expr_ptr);
 
-       } else {
-               expr_ptr = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-               if (IS_TMP_VAR == IS_TMP_VAR) {
-                       ZVAL_COPY_VALUE(&new_expr, expr_ptr);
-                       expr_ptr = &new_expr;
-               } else if (IS_TMP_VAR == IS_CONST) {
-                       if (!Z_IMMUTABLE_P(expr_ptr)) {
-                               ZVAL_DUP(&new_expr, expr_ptr);
-                               expr_ptr = &new_expr;
-                       }
-               } else if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) && Z_ISREF_P(expr_ptr)) {
-                       expr_ptr = Z_REFVAL_P(expr_ptr);
-                       if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
+       arg = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+       param = ZEND_CALL_ARG(EX(call), opline->op2.num);
 
-               } else if (IS_TMP_VAR == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
-                       Z_ADDREF_P(expr_ptr);
-               }
-       }
+       if (ARG_SHOULD_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
+               // TODO: Scalar values don't have reference counters anymore.
+               // They are assumed to be 1, and they may be easily passed by
+               // reference now. However, previously scalars with refcount==1
+               // might be passed and with refcount>1 might not. We can support
+               // only single behavior ???
+#if 0
+               if (Z_REFCOUNTED_P(arg) &&
+                       // This solution breaks the following test (omit warning message) ???
+                       // Zend/tests/bug61273.phpt
+                       // ext/reflection/tests/bug42976.phpt
+                       // ext/standard/tests/general_functions/call_user_func_array_variation_001.phpt
+#else
+               if (!Z_REFCOUNTED_P(arg) ||
+                       // This solution breaks the following test (emit warning message) ???
+                       // ext/pdo_sqlite/tests/pdo_005.phpt
+#endif
+                   (!Z_ISREF_P(arg) /*&& Z_REFCOUNT_P(arg) > 1???*/)) {
 
-       if (IS_CV != IS_UNUSED) {
+                       if (!ARG_MAY_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
 
-               zval *offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
-               zend_string *str;
-               zend_ulong hval;
+                               zend_error(E_WARNING, "Parameter %d to %s%s%s() expected to be a reference, value given",
+                                       opline->op2.num,
+                                       EX(call)->func->common.scope ? EX(call)->func->common.scope->name->val : "",
+                                       EX(call)->func->common.scope ? "::" : "",
+                                       EX(call)->func->common.function_name->val);
 
-add_again:
-               switch (Z_TYPE_P(offset)) {
-                       case IS_DOUBLE:
-                               hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                               goto num_index;
-                       case IS_LONG:
-                               hval = Z_LVAL_P(offset);
-num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
-                               break;
-                       case IS_STRING:
-                               str = Z_STR_P(offset);
-                               if (IS_CV != IS_CONST) {
-                                       if (ZEND_HANDLE_NUMERIC(str, hval)) {
-                                               goto num_index;
-                                       }
+                               if (EX(call)->func->common.fn_flags & ZEND_ACC_CLOSURE) {
+                                       OBJ_RELEASE((zend_object*)EX(call)->func->common.prototype);
                                }
-str_index:
-                               zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
-                               break;
-                       case IS_NULL:
-                               str = STR_EMPTY_ALLOC();
-                               goto str_index;
-                       case IS_FALSE:
-                               hval = 0;
-                               goto num_index;
-                       case IS_TRUE:
-                               hval = 1;
-                               goto num_index;
-                       case IS_REFERENCE:
-                               offset = Z_REFVAL_P(offset);
-                               goto add_again;
-                               break;
-                       default:
-                               zend_error(E_WARNING, "Illegal offset type");
-                               zval_ptr_dtor(expr_ptr);
-                               /* do nothing */
-                               break;
-               }
+                               if (Z_OBJ(EX(call)->This)) {
+                                       OBJ_RELEASE(Z_OBJ(EX(call)->This));
+                               }
+                               EX(call)->func = (zend_function*)&zend_pass_function;
+                               EX(call)->called_scope = NULL;
+                               Z_OBJ(EX(call)->This) = NULL;
+
+                               zval_ptr_dtor_nogc(free_op1);
+                               CHECK_EXCEPTION();
+                               ZEND_VM_NEXT_OPCODE();
+                       }
 
+                       if (Z_REFCOUNTED_P(arg)) {
+                               Z_DELREF_P(arg);
+                       }
+                       ZVAL_DUP(&tmp, arg);
+                       ZVAL_NEW_REF(arg, &tmp);
+                       Z_ADDREF_P(arg);
+               } else if (!Z_ISREF_P(arg)) {
+                       ZVAL_NEW_REF(arg, arg);
+                       Z_ADDREF_P(arg);
+               } else if (Z_REFCOUNTED_P(arg)) {
+                       Z_ADDREF_P(arg);
+               }
+               ZVAL_COPY_VALUE(param, arg);
+       } else if (Z_ISREF_P(arg) &&
+                  /* don't separate references for __call */
+                  (EX(call)->func->common.fn_flags & ZEND_ACC_CALL_VIA_HANDLER) == 0) {
+               ZVAL_DUP(param, Z_REFVAL_P(arg));
        } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
+               ZVAL_COPY(param, arg);
        }
+
+       ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
+
+       zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_NEW_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zval *array;
-       uint32_t size;
        USE_OPLINE
+       zval object_zval;
+       zend_function *constructor;
+       zend_class_entry *ce;
 
-       array = EX_VAR(opline->result.var);
-       if (IS_TMP_VAR != IS_UNUSED) {
-               size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
+       SAVE_OPLINE();
+       if (IS_VAR == IS_CONST) {
+               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv))) {
+                       ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv));
+               } else {
+                       ce = zend_fetch_class_by_name(Z_STR_P(opline->op1.zv), opline->op1.zv + 1, 0 TSRMLS_CC);
+                       if (UNEXPECTED(ce == NULL)) {
+                               CHECK_EXCEPTION();
+                               ZEND_VM_NEXT_OPCODE();
+                       }
+                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op1.zv), ce);
+               }
        } else {
-               size = 0;
+               ce = Z_CE_P(EX_VAR(opline->op1.var));
        }
-       ZVAL_NEW_ARR(array);
-       zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
-
-       if (IS_TMP_VAR != IS_UNUSED) {
-               /* Explicitly initialize array as not-packed if flag is set */
-               if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
-                       zend_hash_real_init(Z_ARRVAL_P(array), 0);
+       if (UNEXPECTED((ce->ce_flags & (ZEND_ACC_INTERFACE|ZEND_ACC_IMPLICIT_ABSTRACT_CLASS|ZEND_ACC_EXPLICIT_ABSTRACT_CLASS)) != 0)) {
+               if (ce->ce_flags & ZEND_ACC_INTERFACE) {
+                       zend_error_noreturn(E_ERROR, "Cannot instantiate interface %s", ce->name->val);
+               } else if ((ce->ce_flags & ZEND_ACC_TRAIT) == ZEND_ACC_TRAIT) {
+                       zend_error_noreturn(E_ERROR, "Cannot instantiate trait %s", ce->name->val);
+               } else {
+                       zend_error_noreturn(E_ERROR, "Cannot instantiate abstract class %s", ce->name->val);
                }
        }
+       object_init_ex(&object_zval, ce);
+       constructor = Z_OBJ_HT(object_zval)->get_constructor(Z_OBJ(object_zval) TSRMLS_CC);
 
-       if (IS_TMP_VAR == IS_UNUSED) {
-               ZEND_VM_NEXT_OPCODE();
-#if 0 || IS_TMP_VAR != IS_UNUSED
+       if (constructor == NULL) {
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_COPY_VALUE(EX_VAR(opline->result.var), &object_zval);
+               } else {
+                       OBJ_RELEASE(Z_OBJ(object_zval));
+               }
+               ZEND_VM_JMP(opline->op2.jmp_addr);
        } else {
-               return ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-#endif
+               /* We are not handling overloaded classes right now */
+               EX(call) = zend_vm_stack_push_call_frame(
+                               ZEND_CALL_FUNCTION | ZEND_CALL_CTOR |
+                               (RETURN_VALUE_USED(opline) ? 0 : ZEND_CALL_CTOR_RESULT_UNUSED),
+                       constructor,
+                       opline->extended_value,
+                       ce,
+                       Z_OBJ(object_zval),
+                       EX(call) TSRMLS_CC);
+
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_COPY(EX_VAR(opline->result.var), &object_zval);
+                       EX(call)->return_value = EX_VAR(opline->result.var);
+               } else {
+                       EX(call)->return_value = NULL;
+               }
+
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_CLONE_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
-       zval *container;
-       int result;
-       zend_ulong hval;
-       zval *offset;
+       zval *obj;
+       zend_class_entry *ce;
+       zend_function *clone;
+       zend_object_clone_obj_t clone_call;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-       offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
-
-       if (IS_TMP_VAR != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
-               HashTable *ht = Z_ARRVAL_P(container);
-               zval *value;
-               zend_string *str;
+       obj = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
 
-isset_again:
-               if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
-                       str = Z_STR_P(offset);
-                       if (IS_CV != IS_CONST) {
-                               if (ZEND_HANDLE_NUMERIC(str, hval)) {
-                                       goto num_index_prop;
-                               }
-                       }
-str_index_prop:
-                       value = zend_hash_find_ind(ht, str);
-               } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
-                       hval = Z_LVAL_P(offset);
-num_index_prop:
-                       value = zend_hash_index_find(ht, hval);
-               } else {
-                       switch (Z_TYPE_P(offset)) {
-                               case IS_DOUBLE:
-                                       hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                                       goto num_index_prop;
-                               case IS_NULL:
-                                       str = STR_EMPTY_ALLOC();
-                                       goto str_index_prop;
-                               case IS_FALSE:
-                                       hval = 0;
-                                       goto num_index_prop;
-                               case IS_TRUE:
-                                       hval = 1;
-                                       goto num_index_prop;
-                               case IS_RESOURCE:
-                                       hval = Z_RES_HANDLE_P(offset);
-                                       goto num_index_prop;
-                               case IS_REFERENCE:
-                                       offset = Z_REFVAL_P(offset);
-                                       goto isset_again;
-                               default:
-                                       zend_error(E_WARNING, "Illegal offset type in isset or empty");
-                                       value = NULL;
-                                       break;
-                       }
+       if (IS_VAR == IS_CONST ||
+           (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(obj) != IS_OBJECT))) {
+               if (UNEXPECTED(EG(exception) != NULL)) {
+                       HANDLE_EXCEPTION();
                }
+               zend_error_noreturn(E_ERROR, "__clone method called on non-object");
+       }
 
-               if (opline->extended_value & ZEND_ISSET) {
-                       /* > IS_NULL means not IS_UNDEF and not IS_NULL */
-                       result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
-               }
-       } else if (IS_TMP_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
-                       result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
+       ce = Z_OBJCE_P(obj);
+       clone = ce ? ce->clone : NULL;
+       clone_call =  Z_OBJ_HT_P(obj)->clone_obj;
+       if (UNEXPECTED(clone_call == NULL)) {
+               if (ce) {
+                       zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object of class %s", ce->name->val);
                } else {
-                       zend_error(E_NOTICE, "Trying to check element of non-array");
-                       result = 0;
-               }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
+                       zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object");
                }
-       } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
-               zval tmp;
+       }
 
-               result = 0;
-               if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
-                       if (IS_CV == IS_CV || IS_CV == IS_VAR) {
-                               ZVAL_DEREF(offset);
+       if (ce && clone) {
+               if (clone->op_array.fn_flags & ZEND_ACC_PRIVATE) {
+                       /* Ensure that if we're calling a private function, we're allowed to do so.
+                        */
+                       if (UNEXPECTED(ce != EG(scope))) {
+                               zend_error_noreturn(E_ERROR, "Call to private %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
                        }
-                       if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
-                                       || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
-                                               && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
-                               ZVAL_DUP(&tmp, offset);
-                               convert_to_long(&tmp);
-                               offset = &tmp;
+               } else if ((clone->common.fn_flags & ZEND_ACC_PROTECTED)) {
+                       /* Ensure that if we're calling a protected function, we're allowed to do so.
+                        */
+                       if (UNEXPECTED(!zend_check_protected(zend_get_function_root_class(clone), EG(scope)))) {
+                               zend_error_noreturn(E_ERROR, "Call to protected %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
                        }
                }
-               if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
-                       if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
-                               if ((opline->extended_value & ZEND_ISSET) ||
-                                   Z_STRVAL_P(container)[offset->value.lval] != '0') {
-                                       result = 1;
-                               }
-                       }
-               }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
-               }
-       } else {
-               result = ((opline->extended_value & ZEND_ISSET) == 0);
        }
 
-       ZVAL_BOOL(EX_VAR(opline->result.var), result);
+       if (EXPECTED(EG(exception) == NULL)) {
+               ZVAL_OBJ(EX_VAR(opline->result.var), clone_call(obj TSRMLS_CC));
+               if (!RETURN_VALUE_USED(opline) || UNEXPECTED(EG(exception) != NULL)) {
+                       OBJ_RELEASE(Z_OBJ_P(EX_VAR(opline->result.var)));
+               }
+       }
        zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_CAST_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
-       zval *container;
-       int result;
-       zval *offset;
+       zval *expr;
+       zval *result = EX_VAR(opline->result.var);
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-       offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+       expr = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
 
-       if (IS_TMP_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
-                       result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
-               } else {
-                       zend_error(E_NOTICE, "Trying to check property of non-object");
-                       result = 0;
-               }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
-               }
-       } else {
-               result = ((opline->extended_value & ZEND_ISSET) == 0);
+       switch (opline->extended_value) {
+               case IS_NULL:
+                       /* This code is taken from convert_to_null. However, it does not seems very useful,
+                        * because a conversion to null always results in the same value. This could only
+                        * be relevant if a cast_object handler for IS_NULL has some kind of side-effect. */
+#if 0
+                       if (IS_VAR == IS_VAR || IS_VAR == IS_CV) {
+                               ZVAL_DEREF(expr);
+                       }
+                       if (Z_TYPE_P(expr) == IS_OBJECT && Z_OBJ_HT_P(expr)->cast_object) {
+                               if (Z_OBJ_HT_P(expr)->cast_object(expr, result, IS_NULL TSRMLS_CC) == SUCCESS) {
+                                       break;
+                               }
+                       }
+#endif
+
+                       ZVAL_NULL(result);
+                       break;
+               case _IS_BOOL:
+                       ZVAL_BOOL(result, zend_is_true(expr TSRMLS_CC));
+                       break;
+               case IS_LONG:
+                       ZVAL_LONG(result, zval_get_long(expr));
+                       break;
+               case IS_DOUBLE:
+                       ZVAL_DOUBLE(result, zval_get_double(expr));
+                       break;
+               case IS_STRING:
+                       ZVAL_STR(result, zval_get_string(expr));
+                       break;
+               default:
+                       /* If value is already of correct type, return it directly */
+                       if (Z_TYPE_P(expr) == opline->extended_value) {
+                               ZVAL_COPY_VALUE(result, expr);
+                               if (IS_VAR == IS_CONST) {
+                                       if (UNEXPECTED(Z_OPT_COPYABLE_P(result))) {
+                                               zval_copy_ctor_func(result);
+                                       }
+                               } else if (IS_VAR != IS_TMP_VAR) {
+                                       if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
+                               }
+
+                               zval_ptr_dtor_nogc(free_op1);
+                               CHECK_EXCEPTION();
+                               ZEND_VM_NEXT_OPCODE();
+                       }
+
+                       if (opline->extended_value == IS_ARRAY) {
+                               if (Z_TYPE_P(expr) != IS_OBJECT) {
+                                       ZVAL_NEW_ARR(result);
+                                       zend_hash_init(Z_ARRVAL_P(result), 8, NULL, ZVAL_PTR_DTOR, 0);
+                                       if (Z_TYPE_P(expr) != IS_NULL) {
+                                               expr = zend_hash_index_add_new(Z_ARRVAL_P(result), 0, expr);
+                                               if (IS_VAR == IS_CONST) {
+                                                       if (UNEXPECTED(Z_OPT_COPYABLE_P(expr))) {
+                                                               zval_copy_ctor_func(expr);
+                                                       }
+                                               } else {
+                                                       if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
+                                               }
+                                       }
+                               } else {
+                                       ZVAL_COPY_VALUE(result, expr);
+                                       Z_ADDREF_P(result);
+                                       convert_to_array(result);
+                               }
+                       } else {
+                               if (Z_TYPE_P(expr) != IS_ARRAY) {
+                                       object_init(result);
+                                       if (Z_TYPE_P(expr) != IS_NULL) {
+                                               expr = zend_hash_str_add_new(Z_OBJPROP_P(result), "scalar", sizeof("scalar")-1, expr);
+                                               if (IS_VAR == IS_CONST) {
+                                                       if (UNEXPECTED(Z_OPT_COPYABLE_P(expr))) {
+                                                               zval_copy_ctor_func(expr);
+                                                       }
+                                               } else {
+                                                       if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
+                                               }
+                                       }
+                               } else {
+                                       ZVAL_COPY_VALUE(result, expr);
+                                       zval_opt_copy_ctor(result);
+                                       convert_to_object(result);
+                               }
+                       }
        }
 
-       ZVAL_BOOL(EX_VAR(opline->result.var), result);
        zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_YIELD_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zend_free_op free_op1;
+       zval *array_ptr, *array_ref, iterator, tmp;
+       HashTable *fe_ht;
+       zend_object_iterator *iter = NULL;
+       zend_class_entry *ce = NULL;
+       zend_bool is_empty = 0;
 
-       /* The generator object is stored in EX(return_value) */
-       zend_generator *generator = (zend_generator *) EX(return_value);
-
-       if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
-               zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
-       }
-
-       /* Destroy the previously yielded value */
-       zval_ptr_dtor(&generator->value);
-
-       /* Destroy the previously yielded key */
-       zval_ptr_dtor(&generator->key);
-
-       /* Set the new yielded value */
-       if (IS_TMP_VAR != IS_UNUSED) {
-               zend_free_op free_op1;
-
-               if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
-                       /* Constants and temporary variables aren't yieldable by reference,
-                        * but we still allow them with a notice. */
-                       if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
-                               zval *value;
-
-                               zend_error(E_NOTICE, "Only variable references should be yielded by reference");
-
-                               value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-                               ZVAL_COPY_VALUE(&generator->value, value);
-                               if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
-
-                               /* Temporary variables don't need ctor copying */
-                               if (IS_TMP_VAR != IS_TMP_VAR) {
-                                       zval_opt_copy_ctor(&generator->value);
-                               }
-                       } else {
-                               zval *value_ptr = NULL;
+       SAVE_OPLINE();
 
-                               if (IS_TMP_VAR == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
-                                       zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
+       if ((IS_VAR == IS_CV || IS_VAR == IS_VAR) &&
+           (opline->extended_value & ZEND_FE_FETCH_BYREF)) {
+               array_ptr = array_ref = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+               ZVAL_DEREF(array_ptr);
+               if (Z_TYPE_P(array_ptr) == IS_ARRAY) {
+                       SEPARATE_ARRAY(array_ptr);
+                       if (!Z_ISREF_P(array_ref)) {
+                               ZVAL_NEW_REF(array_ref, array_ref);
+                               array_ptr = Z_REFVAL_P(array_ref);
+                       }
+                       if (Z_REFCOUNTED_P(array_ref)) Z_ADDREF_P(array_ref);
+               } else if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
+                       ce = Z_OBJCE_P(array_ptr);
+                       if (ce->get_iterator == NULL) {
+                               Z_ADDREF_P(array_ptr);
+                       }
+                       array_ref = array_ptr;
+               } else {
+                       if (Z_REFCOUNTED_P(array_ref)) Z_ADDREF_P(array_ref);
+               }
+       } else {
+               array_ptr = array_ref = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+               ZVAL_DEREF(array_ptr);
+               if (IS_VAR == IS_TMP_VAR) {
+                       ZVAL_COPY_VALUE(&tmp, array_ptr);
+                       if (Z_OPT_IMMUTABLE_P(&tmp)) {
+                               zval_copy_ctor_func(&tmp);
+                       }
+                       array_ref = array_ptr = &tmp;
+                       if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
+                               ce = Z_OBJCE_P(array_ptr);
+                               if (ce && ce->get_iterator) {
+                                       Z_DELREF_P(array_ref);
                                }
-
-                               /* If a function call result is yielded and the function did
-                                * not return by reference we throw a notice. */
-                               if (IS_TMP_VAR == IS_VAR &&
-                                   (value_ptr == &EG(uninitialized_zval) ||
-                                    (opline->extended_value == ZEND_RETURNS_FUNCTION &&
-                                     !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
-                                       zend_error(E_NOTICE, "Only variable references should be yielded by reference");
-                               } else {
-                                       ZVAL_MAKE_REF(value_ptr);
+                       }
+               } else if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
+                       ce = Z_OBJCE_P(array_ptr);
+                       if (!ce->get_iterator) {
+                               if (IS_VAR == IS_CV) {
+                                       Z_ADDREF_P(array_ref);
                                }
-                               ZVAL_COPY(&generator->value, value_ptr);
-
                        }
-               } else {
-                       zval *value = _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1);
-
-                       /* Consts, temporary variables and references need copying */
-                       if (IS_TMP_VAR == IS_CONST) {
-                               ZVAL_DUP(&generator->value, value);
-                       } else if (IS_TMP_VAR == IS_TMP_VAR) {
-                               ZVAL_COPY_VALUE(&generator->value, value);
-            } else if ((IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) && Z_ISREF_P(value)) {
-                               ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
-
+               } else if (Z_IMMUTABLE_P(array_ref)) {
+                       if (IS_VAR == IS_CV) {
+                               zval_copy_ctor_func(array_ref);
+                               Z_ADDREF_P(array_ref);
                        } else {
-                               ZVAL_COPY_VALUE(&generator->value, value);
-                               if (IS_TMP_VAR == IS_CV) {
-                                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+                               ZVAL_COPY_VALUE(&tmp, array_ref);
+                               zval_copy_ctor_func(&tmp);
+                               array_ptr = array_ref = &tmp;
+                       }
+               } else if (Z_REFCOUNTED_P(array_ref)) {
+                       if (IS_VAR == IS_CONST ||
+                                  (IS_VAR == IS_CV &&
+                                   !Z_ISREF_P(array_ref) &&
+                                   Z_REFCOUNT_P(array_ref) > 1) ||
+                                  (IS_VAR == IS_VAR &&
+                                   !Z_ISREF_P(array_ref) &&
+                                   Z_REFCOUNT_P(array_ref) > 2)) {
+                               if (IS_VAR == IS_VAR) {
+                                       Z_DELREF_P(array_ref);
+                               }
+                               ZVAL_DUP(&tmp, array_ref);
+                               array_ptr = array_ref = &tmp;
+                       } else if (IS_VAR == IS_CV || IS_VAR == IS_VAR) {
+                               if (Z_ISREF_P(array_ref) && Z_REFCOUNT_P(array_ref) == 1) {
+                                       ZVAL_UNREF(array_ref);
+                                       array_ptr = array_ref;
+                               }
+                               if (Z_IMMUTABLE_P(array_ptr)) {
+                                       zval_copy_ctor_func(array_ptr);
+                               } else if (Z_ISREF_P(array_ref) &&
+                                          Z_COPYABLE_P(array_ptr) &&
+                                          Z_REFCOUNT_P(array_ptr) > 1) {
+                                       Z_DELREF_P(array_ptr);
+                                       zval_copy_ctor_func(array_ptr);
+                               }
+                               if (IS_VAR == IS_CV) {
+                                       Z_ADDREF_P(array_ref);
                                }
                        }
                }
-       } else {
-               /* If no value was specified yield null */
-               ZVAL_NULL(&generator->value);
        }
 
-       /* Set the new yielded key */
-       if (IS_CV != IS_UNUSED) {
-
-               zval *key = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
-
-               /* Consts, temporary variables and references need copying */
-               if (IS_CV == IS_CONST) {
-                       ZVAL_DUP(&generator->key, key);
-               } else if (IS_CV == IS_TMP_VAR) {
-                       ZVAL_COPY_VALUE(&generator->key, key);
-               } else if ((IS_CV == IS_VAR || IS_CV == IS_CV) && Z_ISREF_P(key)) {
-                       ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
+       if (ce && ce->get_iterator) {
+               iter = ce->get_iterator(ce, array_ptr, opline->extended_value & ZEND_FE_FETCH_BYREF TSRMLS_CC);
 
+               if (IS_VAR == IS_VAR && !(opline->extended_value & ZEND_FE_FETCH_BYREF)) {
+                       zval_ptr_dtor_nogc(free_op1);
+               }
+               if (iter && EXPECTED(EG(exception) == NULL)) {
+                       ZVAL_OBJ(&iterator, &iter->std);
+                       array_ptr = array_ref = &iterator;
                } else {
-                       ZVAL_COPY_VALUE(&generator->key, key);
-                       if (IS_CV == IS_CV) {
-                               if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
+                       if (IS_VAR == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
+                               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
                        }
+                       if (!EG(exception)) {
+                               zend_throw_exception_ex(NULL, 0 TSRMLS_CC, "Object of type %s did not create an Iterator", ce->name->val);
+                       }
+                       zend_throw_exception_internal(NULL TSRMLS_CC);
+                       HANDLE_EXCEPTION();
                }
-
-               if (Z_TYPE(generator->key) == IS_LONG
-                   && Z_LVAL(generator->key) > generator->largest_used_integer_key
-               ) {
-                       generator->largest_used_integer_key = Z_LVAL(generator->key);
-               }
-       } else {
-               /* If no key was specified we use auto-increment keys */
-               generator->largest_used_integer_key++;
-               ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
-       }
-
-       if (RETURN_VALUE_USED(opline)) {
-               /* If the return value of yield is used set the send
-                * target and initialize it to NULL */
-               generator->send_target = EX_VAR(opline->result.var);
-               ZVAL_NULL(generator->send_target);
-       } else {
-               generator->send_target = NULL;
        }
 
-       /* We increment to the next op, so we are at the correct position when the
-        * generator is resumed. */
-       ZEND_VM_INC_OPCODE();
-
-       /* The GOTO VM uses a local opline variable. We need to set the opline
-        * variable in execute_data so we don't resume at an old position. */
-       SAVE_OPLINE();
-
-       ZEND_VM_RETURN();
-}
-
-static int ZEND_FASTCALL  ZEND_POW_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-       pow_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_tmp(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_BW_NOT_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-       bitwise_not_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1) TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_BOOL_NOT_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-       boolean_not_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1) TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_PRE_INC_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *var_ptr;
-
-       SAVE_OPLINE();
-       var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+       ZVAL_COPY_VALUE(EX_VAR(opline->result.var), array_ref);
 
-       if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
-       }
+       if (iter) {
+               iter->index = 0;
+               if (iter->funcs->rewind) {
+                       iter->funcs->rewind(iter TSRMLS_CC);
+                       if (UNEXPECTED(EG(exception) != NULL)) {
+                               zval_ptr_dtor(array_ref);
+                               if (IS_VAR == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
+                                       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+                               }
+                               HANDLE_EXCEPTION();
+                       }
+               }
+               is_empty = iter->funcs->valid(iter TSRMLS_CC) != SUCCESS;
+               if (UNEXPECTED(EG(exception) != NULL)) {
+                       zval_ptr_dtor(array_ref);
+                       if (IS_VAR == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
+                               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+                       }
+                       HANDLE_EXCEPTION();
+               }
+               iter->index = -1; /* will be set to 0 before using next handler */
+       } else if ((fe_ht = HASH_OF(array_ptr)) != NULL) {
+               HashPointer *ptr = (HashPointer*)EX_VAR((opline+2)->op1.var);
+               HashPosition pos = 0;
+               Bucket *p;
 
-       if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
-               fast_increment_function(var_ptr);
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
+               while (1) {
+                       if (pos >= fe_ht->nNumUsed) {
+                               is_empty = 1;
+                               if (IS_VAR == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
+                                       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+                               }
+                               ZEND_VM_JMP(opline->op2.jmp_addr);
+                       }
+                       p = fe_ht->arData + pos;
+                       if (Z_TYPE(p->val) == IS_UNDEF ||
+                           (Z_TYPE(p->val) == IS_INDIRECT &&
+                            Z_TYPE_P(Z_INDIRECT(p->val)) == IS_UNDEF)) {
+                               pos++;
+                               continue;
+                       }
+                       if (!ce ||
+                           !p->key ||
+                           zend_check_property_access(Z_OBJ_P(array_ptr), p->key TSRMLS_CC) == SUCCESS) {
+                               break;
+                       }
+                       pos++;
                }
-               ZEND_VM_NEXT_OPCODE();
+               fe_ht->nInternalPointer = pos;
+               ptr->pos = pos;
+               ptr->ht = fe_ht;
+               ptr->h = fe_ht->arData[pos].h;
+               ptr->key = fe_ht->arData[pos].key;
+               is_empty = 0;
+       } else {
+               zend_error(E_WARNING, "Invalid argument supplied for foreach()");
+               is_empty = 1;
        }
 
-       if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
-               }
+       if (IS_VAR == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
+               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+       }
+       if (is_empty) {
+               ZEND_VM_JMP(opline->op2.jmp_addr);
+       } else {
                CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
-
-       ZVAL_DEREF(var_ptr);
-       SEPARATE_ZVAL_NOREF(var_ptr);
-
-       increment_function(var_ptr);
-
-       if (RETURN_VALUE_USED(opline)) {
-               ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
-       }
-
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_PRE_DEC_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FE_FETCH_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
-       zval *var_ptr;
 
-       SAVE_OPLINE();
-       var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
-       }
-
-       if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
-               fast_decrement_function(var_ptr);
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
-               }
-               ZEND_VM_NEXT_OPCODE();
-       }
+       zval *array, *array_ref;
+       zval *value;
+       HashTable *fe_ht;
+       HashPointer *ptr;
+       HashPosition pos;
+       Bucket *p;
 
-       if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
+       array = array_ref = EX_VAR(opline->op1.var);
+       if (Z_ISREF_P(array)) {
+               array = Z_REFVAL_P(array);
+               // TODO: referenced value might be changed to different array ???
+               if (Z_IMMUTABLE_P(array)) {
+                       zval_copy_ctor_func(array);
                }
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
        }
 
-       ZVAL_DEREF(var_ptr);
-       SEPARATE_ZVAL_NOREF(var_ptr);
-
-       decrement_function(var_ptr);
-
-       if (RETURN_VALUE_USED(opline)) {
-               ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
-       }
+       SAVE_OPLINE();
 
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_POST_INC_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *var_ptr;
-
-       SAVE_OPLINE();
-       var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
-       }
-
-       if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
-               ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
-               fast_increment_function(var_ptr);
-               ZEND_VM_NEXT_OPCODE();
-       }
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
-               ZVAL_NULL(EX_VAR(opline->result.var));
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
-
-       ZVAL_DEREF(var_ptr);
-       ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
-       zval_opt_copy_ctor(var_ptr);
-
-       increment_function(var_ptr);
-
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_POST_DEC_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *var_ptr;
-
-       SAVE_OPLINE();
-       var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
-       }
-
-       if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
-               ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
-               fast_decrement_function(var_ptr);
-               ZEND_VM_NEXT_OPCODE();
-       }
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
-               ZVAL_NULL(EX_VAR(opline->result.var));
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
-
-       ZVAL_DEREF(var_ptr);
-       ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
-       zval_opt_copy_ctor(var_ptr);
-
-       decrement_function(var_ptr);
-
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_ECHO_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *z;
-
-       SAVE_OPLINE();
-       z = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
-       zend_print_variable(z TSRMLS_CC);
-
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_PRINT_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       ZVAL_LONG(EX_VAR(opline->result.var), 1);
-       return ZEND_ECHO_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_JMPZ_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *val;
-
-       SAVE_OPLINE();
-       val = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR == IS_TMP_VAR) {
-               if (Z_TYPE_P(val) == IS_TRUE) {
-                       ZEND_VM_SET_OPCODE(opline + 1);
-                       ZEND_VM_CONTINUE();
-               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
-                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
-                       ZEND_VM_CONTINUE();
-               }
-       }
-
-       if (i_zend_is_true(val TSRMLS_CC)) {
-               opline++;
-       } else {
-               opline = opline->op2.jmp_addr;
-       }
-       zval_ptr_dtor_nogc(free_op1);
-       if (UNEXPECTED(EG(exception) != NULL)) {
-               HANDLE_EXCEPTION();
-       }
-       ZEND_VM_JMP(opline);
-}
-
-static int ZEND_FASTCALL  ZEND_JMPNZ_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *val;
-
-       SAVE_OPLINE();
-       val = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR == IS_TMP_VAR) {
-               if (Z_TYPE_P(val) == IS_TRUE) {
-                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
-                       ZEND_VM_CONTINUE();
-               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
-                       ZEND_VM_SET_OPCODE(opline + 1);
-                       ZEND_VM_CONTINUE();
-               }
-       }
-
-       if (i_zend_is_true(val TSRMLS_CC)) {
-               opline = opline->op2.jmp_addr;
-       } else {
-               opline++;
-       }
-       zval_ptr_dtor_nogc(free_op1);
-       if (UNEXPECTED(EG(exception) != NULL)) {
-               HANDLE_EXCEPTION();
-       }
-       ZEND_VM_JMP(opline);
-}
-
-static int ZEND_FASTCALL  ZEND_JMPZNZ_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *val;
-
-       SAVE_OPLINE();
-       val = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR == IS_TMP_VAR) {
-               if (EXPECTED(Z_TYPE_P(val) == IS_TRUE)) {
-                       ZEND_VM_SET_RELATIVE_OPCODE(opline, opline->extended_value);
-                       ZEND_VM_CONTINUE();
-               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
-                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
-                       ZEND_VM_CONTINUE();
-               }
-       }
-
-       if (i_zend_is_true(val TSRMLS_CC)) {
-               opline = (zend_op*)(((char*)opline) + opline->extended_value);
-       } else {
-               opline = opline->op2.jmp_addr;
-       }
-       zval_ptr_dtor_nogc(free_op1);
-       if (UNEXPECTED(EG(exception) != NULL)) {
-               HANDLE_EXCEPTION();
-       }
-       ZEND_VM_JMP(opline);
-}
-
-static int ZEND_FASTCALL  ZEND_JMPZ_EX_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *val;
-
-       SAVE_OPLINE();
-       val = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR == IS_TMP_VAR) {
-               if (Z_TYPE_P(val) == IS_TRUE) {
-                       ZVAL_TRUE(EX_VAR(opline->result.var));
-                       ZEND_VM_SET_OPCODE(opline + 1);
-                       ZEND_VM_CONTINUE();
-               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
-                       ZVAL_FALSE(EX_VAR(opline->result.var));
-                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
-                       ZEND_VM_CONTINUE();
-               }
-       }
-
-       if (i_zend_is_true(val TSRMLS_CC)) {
-               zval_ptr_dtor_nogc(free_op1);
-               ZVAL_TRUE(EX_VAR(opline->result.var));
-               opline++;
-       } else {
-               zval_ptr_dtor_nogc(free_op1);
-               ZVAL_FALSE(EX_VAR(opline->result.var));
-               opline = opline->op2.jmp_addr;
-       }
-       if (UNEXPECTED(EG(exception) != NULL)) {
-               HANDLE_EXCEPTION();
-       }
-       ZEND_VM_JMP(opline);
-}
-
-static int ZEND_FASTCALL  ZEND_JMPNZ_EX_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *val;
-
-       SAVE_OPLINE();
-       val = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR == IS_TMP_VAR) {
-               if (Z_TYPE_P(val) == IS_TRUE) {
-                       ZVAL_TRUE(EX_VAR(opline->result.var));
-                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
-                       ZEND_VM_CONTINUE();
-               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
-                       ZVAL_FALSE(EX_VAR(opline->result.var));
-                       ZEND_VM_SET_OPCODE(opline + 1);
-                       ZEND_VM_CONTINUE();
-               }
-       }
-       if (i_zend_is_true(val TSRMLS_CC)) {
-               ZVAL_TRUE(EX_VAR(opline->result.var));
-               opline = opline->op2.jmp_addr;
-       } else {
-               ZVAL_FALSE(EX_VAR(opline->result.var));
-               opline++;
-       }
-       zval_ptr_dtor_nogc(free_op1);
-       if (UNEXPECTED(EG(exception) != NULL)) {
-               HANDLE_EXCEPTION();
-       }
-       ZEND_VM_JMP(opline);
-}
-
-static int ZEND_FASTCALL  ZEND_RETURN_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *retval_ptr;
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-       retval_ptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       if (!EX(return_value)) {
-               zval_ptr_dtor_nogc(free_op1);
-       } else {
-               if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
-                       ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
-                       if (IS_VAR == IS_CONST) {
-                               if (UNEXPECTED(Z_OPT_COPYABLE_P(EX(return_value)))) {
-                                       zval_copy_ctor_func(EX(return_value));
-                               }
-                       }
-               } else if ((IS_VAR == IS_CV || IS_VAR == IS_VAR) && Z_ISREF_P(retval_ptr)) {
-                       ZVAL_COPY(EX(return_value), Z_REFVAL_P(retval_ptr));
-                       zval_ptr_dtor_nogc(free_op1);
-               } else {
-                       ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
-                       if (IS_VAR == IS_CV) {
-                               if (Z_OPT_REFCOUNTED_P(retval_ptr)) Z_ADDREF_P(retval_ptr);
-                       }
-               }
-       }
-       return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_RETURN_BY_REF_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *retval_ptr;
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-
-       do {
-               if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR ||
-                   (IS_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_VALUE)) {
-                       /* Not supposed to happen, but we'll allow it */
-                       zend_error(E_NOTICE, "Only variable references should be returned by reference");
-
-                       retval_ptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-                       if (!EX(return_value)) {
-                               if (IS_VAR == IS_TMP_VAR) {
-                                       zval_ptr_dtor_nogc(free_op1);
-                               }
-                       } else {
-                               ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
-                               Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
-                               if (IS_VAR != IS_TMP_VAR) {
-                                       zval_opt_copy_ctor_no_imm(EX(return_value));
-                               }
-                       }
-                       break;
-               }
-
-               retval_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-               if (IS_VAR == IS_VAR && UNEXPECTED(retval_ptr == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot return string offsets by reference");
-               }
-
-               if (IS_VAR == IS_VAR) {
-                       if (retval_ptr == &EG(uninitialized_zval) ||
-                           (opline->extended_value == ZEND_RETURNS_FUNCTION &&
-                            !(Z_VAR_FLAGS_P(retval_ptr) & IS_VAR_RET_REF))) {
-                               zend_error(E_NOTICE, "Only variable references should be returned by reference");
-                               if (EX(return_value)) {
-                                       ZVAL_NEW_REF(EX(return_value), retval_ptr);
-                                       Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
-                                       if (Z_REFCOUNTED_P(retval_ptr)) Z_ADDREF_P(retval_ptr);
-                               }
-                               break;
-                       }
-               }
-
-               if (EX(return_value)) {
-                       ZVAL_MAKE_REF(retval_ptr);
-                       Z_ADDREF_P(retval_ptr);
-                       ZVAL_REF(EX(return_value), Z_REF_P(retval_ptr));
-                       Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
-               }
-       } while (0);
-
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_THROW_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *value;
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-       value = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR == IS_CONST || UNEXPECTED(Z_TYPE_P(value) != IS_OBJECT)) {
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       HANDLE_EXCEPTION();
-               }
-               zend_error_noreturn(E_ERROR, "Can only throw objects");
-       }
-
-       zend_exception_save(TSRMLS_C);
-       if (IS_VAR != IS_TMP_VAR) {
-               if (Z_REFCOUNTED_P(value)) Z_ADDREF_P(value);
-       }
-
-       zend_throw_exception_object(value TSRMLS_CC);
-       zend_exception_restore(TSRMLS_C);
-       zval_ptr_dtor_nogc(free_op1);
-       HANDLE_EXCEPTION();
-}
-
-static int ZEND_FASTCALL  ZEND_SEND_VAR_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *varptr, *arg;
-       zend_free_op free_op1;
-
-       varptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-       arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
-       ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
-       if ((IS_VAR == IS_CV || IS_VAR == IS_VAR) && Z_ISREF_P(varptr)) {
-               ZVAL_COPY(arg, Z_REFVAL_P(varptr));
-               zval_ptr_dtor_nogc(free_op1);
-       } else {
-               ZVAL_COPY_VALUE(arg, varptr);
-               if (IS_VAR == IS_CV) {
-                       if (Z_OPT_REFCOUNTED_P(arg)) Z_ADDREF_P(arg);
-               }
-       }
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_SEND_VAR_NO_REF_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *varptr, *arg;
-
-       SAVE_OPLINE();
-
-       if (!(opline->extended_value & ZEND_ARG_COMPILE_TIME_BOUND)) {
-               if (!ARG_SHOULD_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
-                       return ZEND_SEND_VAR_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-               }
-       }
-
-       varptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-       if ((!(opline->extended_value & ZEND_ARG_SEND_FUNCTION) ||
-            (Z_VAR_FLAGS_P(varptr) & IS_VAR_RET_REF)) &&
-           (Z_ISREF_P(varptr) || Z_TYPE_P(varptr) == IS_OBJECT)) {
-
-               ZVAL_MAKE_REF(varptr);
-               if (IS_VAR == IS_CV) {
-                       Z_ADDREF_P(varptr);
-               }
-       } else {
-               if ((opline->extended_value & ZEND_ARG_COMPILE_TIME_BOUND) ?
-                       !(opline->extended_value & ZEND_ARG_SEND_SILENT) :
-                       !ARG_MAY_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
-                       zend_error(E_STRICT, "Only variables should be passed by reference");
-               }
-       }
-
-       arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
-       ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
-       ZVAL_COPY_VALUE(arg, varptr);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_SEND_REF_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *varptr, *arg;
-
-       SAVE_OPLINE();
-       varptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(varptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Only variables can be passed by reference");
-       }
-
-       arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
-       ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
-       if (IS_VAR == IS_VAR && UNEXPECTED(varptr == &EG(error_zval))) {
-               ZVAL_NEW_REF(arg, &EG(uninitialized_zval));
-               ZEND_VM_NEXT_OPCODE();
-       }
-
-       if (Z_ISREF_P(varptr)) {
-               Z_ADDREF_P(varptr);
-               ZVAL_COPY_VALUE(arg, varptr);
-       } else if (IS_VAR == IS_VAR &&
-               UNEXPECTED(Z_TYPE_P(EX_VAR(opline->op1.var)) != IS_INDIRECT)) {
-               ZVAL_NEW_REF(arg, varptr);
-       } else {
-               ZVAL_NEW_REF(arg, varptr);
-               Z_ADDREF_P(arg);
-               ZVAL_REF(varptr, Z_REF_P(arg));
-       }
-
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_SEND_VAR_EX_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *varptr, *arg;
-       zend_free_op free_op1;
-
-       if (ARG_SHOULD_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
-               return ZEND_SEND_REF_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-       varptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-       arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
-       ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
-       if ((IS_VAR == IS_CV || IS_VAR == IS_VAR) && Z_ISREF_P(varptr)) {
-               ZVAL_COPY(arg, Z_REFVAL_P(varptr));
-               zval_ptr_dtor_nogc(free_op1);
-       } else {
-               ZVAL_COPY_VALUE(arg, varptr);
-               if (IS_VAR == IS_CV) {
-                       if (Z_OPT_REFCOUNTED_P(arg)) Z_ADDREF_P(arg);
-               }
-       }
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_SEND_USER_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *arg, *param, tmp;
-       zend_free_op free_op1;
-
-       arg = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-       param = ZEND_CALL_ARG(EX(call), opline->op2.num);
-
-       if (ARG_SHOULD_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
-               // TODO: Scalar values don't have reference counters anymore.
-               // They are assumed to be 1, and they may be easily passed by
-               // reference now. However, previously scalars with refcount==1
-               // might be passed and with refcount>1 might not. We can support
-               // only single behavior ???
-#if 0
-               if (Z_REFCOUNTED_P(arg) &&
-                       // This solution breaks the following test (omit warning message) ???
-                       // Zend/tests/bug61273.phpt
-                       // ext/reflection/tests/bug42976.phpt
-                       // ext/standard/tests/general_functions/call_user_func_array_variation_001.phpt
-#else
-               if (!Z_REFCOUNTED_P(arg) ||
-                       // This solution breaks the following test (emit warning message) ???
-                       // ext/pdo_sqlite/tests/pdo_005.phpt
-#endif
-                   (!Z_ISREF_P(arg) /*&& Z_REFCOUNT_P(arg) > 1???*/)) {
-
-                       if (!ARG_MAY_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
-
-                               zend_error(E_WARNING, "Parameter %d to %s%s%s() expected to be a reference, value given",
-                                       opline->op2.num,
-                                       EX(call)->func->common.scope ? EX(call)->func->common.scope->name->val : "",
-                                       EX(call)->func->common.scope ? "::" : "",
-                                       EX(call)->func->common.function_name->val);
-
-                               if (EX(call)->func->common.fn_flags & ZEND_ACC_CLOSURE) {
-                                       OBJ_RELEASE((zend_object*)EX(call)->func->common.prototype);
-                               }
-                               if (Z_OBJ(EX(call)->This)) {
-                                       OBJ_RELEASE(Z_OBJ(EX(call)->This));
-                               }
-                               EX(call)->func = (zend_function*)&zend_pass_function;
-                               EX(call)->called_scope = NULL;
-                               Z_OBJ(EX(call)->This) = NULL;
-
-                               zval_ptr_dtor_nogc(free_op1);
-                               CHECK_EXCEPTION();
-                               ZEND_VM_NEXT_OPCODE();
-                       }
-
-                       if (Z_REFCOUNTED_P(arg)) {
-                               Z_DELREF_P(arg);
-                       }
-                       ZVAL_DUP(&tmp, arg);
-                       ZVAL_NEW_REF(arg, &tmp);
-                       Z_ADDREF_P(arg);
-               } else if (!Z_ISREF_P(arg)) {
-                       ZVAL_NEW_REF(arg, arg);
-                       Z_ADDREF_P(arg);
-               } else if (Z_REFCOUNTED_P(arg)) {
-                       Z_ADDREF_P(arg);
-               }
-               ZVAL_COPY_VALUE(param, arg);
-       } else if (Z_ISREF_P(arg) &&
-                  /* don't separate references for __call */
-                  (EX(call)->func->common.fn_flags & ZEND_ACC_CALL_VIA_HANDLER) == 0) {
-               ZVAL_DUP(param, Z_REFVAL_P(arg));
-       } else {
-               ZVAL_COPY(param, arg);
-       }
-
-       ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
-
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_BOOL_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *retval = EX_VAR(opline->result.var);
-
-       SAVE_OPLINE();
-       /* PHP 3.0 returned "" for false and 1 for true, here we use 0 and 1 for now */
-       ZVAL_BOOL(retval, i_zend_is_true(_get_zval_ptr_var(opline->op1.var, execute_data, &free_op1) TSRMLS_CC));
-       zval_ptr_dtor_nogc(free_op1);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_NEW_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval object_zval;
-       zend_function *constructor;
-       zend_class_entry *ce;
-
-       SAVE_OPLINE();
-       if (IS_VAR == IS_CONST) {
-               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv))) {
-                       ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv));
-               } else {
-                       ce = zend_fetch_class_by_name(Z_STR_P(opline->op1.zv), opline->op1.zv + 1, 0 TSRMLS_CC);
-                       if (UNEXPECTED(ce == NULL)) {
-                               CHECK_EXCEPTION();
-                               ZEND_VM_NEXT_OPCODE();
-                       }
-                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op1.zv), ce);
-               }
-       } else {
-               ce = Z_CE_P(EX_VAR(opline->op1.var));
-       }
-       if (UNEXPECTED((ce->ce_flags & (ZEND_ACC_INTERFACE|ZEND_ACC_IMPLICIT_ABSTRACT_CLASS|ZEND_ACC_EXPLICIT_ABSTRACT_CLASS)) != 0)) {
-               if (ce->ce_flags & ZEND_ACC_INTERFACE) {
-                       zend_error_noreturn(E_ERROR, "Cannot instantiate interface %s", ce->name->val);
-               } else if ((ce->ce_flags & ZEND_ACC_TRAIT) == ZEND_ACC_TRAIT) {
-                       zend_error_noreturn(E_ERROR, "Cannot instantiate trait %s", ce->name->val);
-               } else {
-                       zend_error_noreturn(E_ERROR, "Cannot instantiate abstract class %s", ce->name->val);
-               }
-       }
-       object_init_ex(&object_zval, ce);
-       constructor = Z_OBJ_HT(object_zval)->get_constructor(Z_OBJ(object_zval) TSRMLS_CC);
-
-       if (constructor == NULL) {
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_COPY_VALUE(EX_VAR(opline->result.var), &object_zval);
-               } else {
-                       OBJ_RELEASE(Z_OBJ(object_zval));
-               }
-               ZEND_VM_JMP(opline->op2.jmp_addr);
-       } else {
-               /* We are not handling overloaded classes right now */
-               EX(call) = zend_vm_stack_push_call_frame(
-                               ZEND_CALL_FUNCTION | ZEND_CALL_CTOR |
-                               (RETURN_VALUE_USED(opline) ? 0 : ZEND_CALL_CTOR_RESULT_UNUSED),
-                       constructor,
-                       opline->extended_value,
-                       ce,
-                       Z_OBJ(object_zval),
-                       EX(call) TSRMLS_CC);
-
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_COPY(EX_VAR(opline->result.var), &object_zval);
-                       EX(call)->return_value = EX_VAR(opline->result.var);
-               } else {
-                       EX(call)->return_value = NULL;
-               }
-
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_CLONE_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *obj;
-       zend_class_entry *ce;
-       zend_function *clone;
-       zend_object_clone_obj_t clone_call;
-
-       SAVE_OPLINE();
-       obj = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR == IS_CONST ||
-           (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(obj) != IS_OBJECT))) {
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       HANDLE_EXCEPTION();
-               }
-               zend_error_noreturn(E_ERROR, "__clone method called on non-object");
-       }
-
-       ce = Z_OBJCE_P(obj);
-       clone = ce ? ce->clone : NULL;
-       clone_call =  Z_OBJ_HT_P(obj)->clone_obj;
-       if (UNEXPECTED(clone_call == NULL)) {
-               if (ce) {
-                       zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object of class %s", ce->name->val);
-               } else {
-                       zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object");
-               }
-       }
-
-       if (ce && clone) {
-               if (clone->op_array.fn_flags & ZEND_ACC_PRIVATE) {
-                       /* Ensure that if we're calling a private function, we're allowed to do so.
-                        */
-                       if (UNEXPECTED(ce != EG(scope))) {
-                               zend_error_noreturn(E_ERROR, "Call to private %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
-                       }
-               } else if ((clone->common.fn_flags & ZEND_ACC_PROTECTED)) {
-                       /* Ensure that if we're calling a protected function, we're allowed to do so.
-                        */
-                       if (UNEXPECTED(!zend_check_protected(zend_get_function_root_class(clone), EG(scope)))) {
-                               zend_error_noreturn(E_ERROR, "Call to protected %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
-                       }
-               }
-       }
-
-       if (EXPECTED(EG(exception) == NULL)) {
-               ZVAL_OBJ(EX_VAR(opline->result.var), clone_call(obj TSRMLS_CC));
-               if (!RETURN_VALUE_USED(opline) || UNEXPECTED(EG(exception) != NULL)) {
-                       OBJ_RELEASE(Z_OBJ_P(EX_VAR(opline->result.var)));
-               }
-       }
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_CAST_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *expr;
-       zval *result = EX_VAR(opline->result.var);
-
-       SAVE_OPLINE();
-       expr = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
-       switch (opline->extended_value) {
-               case IS_NULL:
-                       /* This code is taken from convert_to_null. However, it does not seems very useful,
-                        * because a conversion to null always results in the same value. This could only
-                        * be relevant if a cast_object handler for IS_NULL has some kind of side-effect. */
-#if 0
-                       if (IS_VAR == IS_VAR || IS_VAR == IS_CV) {
-                               ZVAL_DEREF(expr);
-                       }
-                       if (Z_TYPE_P(expr) == IS_OBJECT && Z_OBJ_HT_P(expr)->cast_object) {
-                               if (Z_OBJ_HT_P(expr)->cast_object(expr, result, IS_NULL TSRMLS_CC) == SUCCESS) {
-                                       break;
-                               }
-                       }
-#endif
-
-                       ZVAL_NULL(result);
-                       break;
-               case _IS_BOOL:
-                       ZVAL_BOOL(result, zend_is_true(expr TSRMLS_CC));
-                       break;
-               case IS_LONG:
-                       ZVAL_LONG(result, zval_get_long(expr));
-                       break;
-               case IS_DOUBLE:
-                       ZVAL_DOUBLE(result, zval_get_double(expr));
-                       break;
-               case IS_STRING:
-                       ZVAL_STR(result, zval_get_string(expr));
-                       break;
-               default:
-                       /* If value is already of correct type, return it directly */
-                       if (Z_TYPE_P(expr) == opline->extended_value) {
-                               ZVAL_COPY_VALUE(result, expr);
-                               if (IS_VAR == IS_CONST) {
-                                       if (UNEXPECTED(Z_OPT_COPYABLE_P(result))) {
-                                               zval_copy_ctor_func(result);
-                                       }
-                               } else if (IS_VAR != IS_TMP_VAR) {
-                                       if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
-                               }
-
-                               zval_ptr_dtor_nogc(free_op1);
-                               CHECK_EXCEPTION();
-                               ZEND_VM_NEXT_OPCODE();
-                       }
-
-                       if (opline->extended_value == IS_ARRAY) {
-                               if (Z_TYPE_P(expr) != IS_OBJECT) {
-                                       ZVAL_NEW_ARR(result);
-                                       zend_hash_init(Z_ARRVAL_P(result), 8, NULL, ZVAL_PTR_DTOR, 0);
-                                       if (Z_TYPE_P(expr) != IS_NULL) {
-                                               expr = zend_hash_index_add_new(Z_ARRVAL_P(result), 0, expr);
-                                               if (IS_VAR == IS_CONST) {
-                                                       if (UNEXPECTED(Z_OPT_COPYABLE_P(expr))) {
-                                                               zval_copy_ctor_func(expr);
-                                                       }
-                                               } else {
-                                                       if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
-                                               }
-                                       }
-                               } else {
-                                       ZVAL_COPY_VALUE(result, expr);
-                                       Z_ADDREF_P(result);
-                                       convert_to_array(result);
-                               }
-                       } else {
-                               if (Z_TYPE_P(expr) != IS_ARRAY) {
-                                       object_init(result);
-                                       if (Z_TYPE_P(expr) != IS_NULL) {
-                                               expr = zend_hash_str_add_new(Z_OBJPROP_P(result), "scalar", sizeof("scalar")-1, expr);
-                                               if (IS_VAR == IS_CONST) {
-                                                       if (UNEXPECTED(Z_OPT_COPYABLE_P(expr))) {
-                                                               zval_copy_ctor_func(expr);
-                                                       }
-                                               } else {
-                                                       if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
-                                               }
-                                       }
-                               } else {
-                                       ZVAL_COPY_VALUE(result, expr);
-                                       zval_opt_copy_ctor(result);
-                                       convert_to_object(result);
-                               }
-                       }
-       }
-
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_INCLUDE_OR_EVAL_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_op_array *new_op_array=NULL;
-       zend_free_op free_op1;
-       zval *inc_filename;
-       zval tmp_inc_filename;
-       zend_bool failure_retval=0;
-
-       SAVE_OPLINE();
-       inc_filename = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       ZVAL_UNDEF(&tmp_inc_filename);
-       if (Z_TYPE_P(inc_filename) != IS_STRING) {
-               ZVAL_STR(&tmp_inc_filename, zval_get_string(inc_filename));
-               inc_filename = &tmp_inc_filename;
-       }
-
-       if (opline->extended_value != ZEND_EVAL && strlen(Z_STRVAL_P(inc_filename)) != Z_STRLEN_P(inc_filename)) {
-               if (opline->extended_value == ZEND_INCLUDE_ONCE || opline->extended_value == ZEND_INCLUDE) {
-                       zend_message_dispatcher(ZMSG_FAILED_INCLUDE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
-               } else {
-                       zend_message_dispatcher(ZMSG_FAILED_REQUIRE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
-               }
-       } else {
-               switch (opline->extended_value) {
-                       case ZEND_INCLUDE_ONCE:
-                       case ZEND_REQUIRE_ONCE: {
-                                       zend_file_handle file_handle;
-                                       char *resolved_path;
-
-                                       resolved_path = zend_resolve_path(Z_STRVAL_P(inc_filename), (int)Z_STRLEN_P(inc_filename) TSRMLS_CC);
-                                       if (resolved_path) {
-                                               failure_retval = zend_hash_str_exists(&EG(included_files), resolved_path, (int)strlen(resolved_path));
-                                       } else {
-                                               resolved_path = Z_STRVAL_P(inc_filename);
-                                       }
-
-                                       if (failure_retval) {
-                                               /* do nothing, file already included */
-                                       } else if (SUCCESS == zend_stream_open(resolved_path, &file_handle TSRMLS_CC)) {
-
-                                               if (!file_handle.opened_path) {
-                                                       file_handle.opened_path = estrdup(resolved_path);
-                                               }
-
-                                               if (zend_hash_str_add_empty_element(&EG(included_files), file_handle.opened_path, (int)strlen(file_handle.opened_path))) {
-                                                       new_op_array = zend_compile_file(&file_handle, (opline->extended_value==ZEND_INCLUDE_ONCE?ZEND_INCLUDE:ZEND_REQUIRE) TSRMLS_CC);
-                                                       zend_destroy_file_handle(&file_handle TSRMLS_CC);
-                                               } else {
-                                                       zend_file_handle_dtor(&file_handle TSRMLS_CC);
-                                                       failure_retval=1;
-                                               }
-                                       } else {
-                                               if (opline->extended_value == ZEND_INCLUDE_ONCE) {
-                                                       zend_message_dispatcher(ZMSG_FAILED_INCLUDE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
-                                               } else {
-                                                       zend_message_dispatcher(ZMSG_FAILED_REQUIRE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
-                                               }
-                                       }
-                                       if (resolved_path != Z_STRVAL_P(inc_filename)) {
-                                               efree(resolved_path);
-                                       }
-                               }
-                               break;
-                       case ZEND_INCLUDE:
-                       case ZEND_REQUIRE:
-                               new_op_array = compile_filename(opline->extended_value, inc_filename TSRMLS_CC);
-                               break;
-                       case ZEND_EVAL: {
-                                       char *eval_desc = zend_make_compiled_string_description("eval()'d code" TSRMLS_CC);
-
-                                       new_op_array = zend_compile_string(inc_filename, eval_desc TSRMLS_CC);
-                                       efree(eval_desc);
-                               }
-                               break;
-                       EMPTY_SWITCH_DEFAULT_CASE()
-               }
-       }
-       if (Z_TYPE(tmp_inc_filename) != IS_UNDEF) {
-               zend_string_release(Z_STR(tmp_inc_filename));
-       }
-       zval_ptr_dtor_nogc(free_op1);
-       if (UNEXPECTED(EG(exception) != NULL)) {
-               HANDLE_EXCEPTION();
-       } else if (EXPECTED(new_op_array != NULL)) {
-               zval *return_value = NULL;
-               zend_execute_data *call;
-
-               if (RETURN_VALUE_USED(opline)) {
-                       return_value = EX_VAR(opline->result.var);
-               }
-
-               new_op_array->scope = EG(scope); /* ??? */
-
-               call = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_CODE,
-                       (zend_function*)new_op_array, 0, EX(called_scope), Z_OBJ(EX(This)), NULL TSRMLS_CC);
-
-               if (EX(symbol_table)) {
-                       call->symbol_table = EX(symbol_table);
-               } else {
-                       call->symbol_table = zend_rebuild_symbol_table(TSRMLS_C);
-               }
-
-               call->prev_execute_data = execute_data;
-           i_init_code_execute_data(call, new_op_array, return_value TSRMLS_CC);
-               if (EXPECTED(zend_execute_ex == execute_ex)) {
-                       ZEND_VM_ENTER();
-               } else {
-                       ZEND_ADD_CALL_FLAG(call, ZEND_CALL_TOP);
-                       zend_execute_ex(call TSRMLS_CC);
-               }
-
-               destroy_op_array(new_op_array TSRMLS_CC);
-               efree_size(new_op_array, sizeof(zend_op_array));
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       zend_throw_exception_internal(NULL TSRMLS_CC);
-                       HANDLE_EXCEPTION();
-               }
-
-       } else if (RETURN_VALUE_USED(opline)) {
-               ZVAL_BOOL(EX_VAR(opline->result.var), failure_retval);
-       }
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *array_ptr, *array_ref, iterator, tmp;
-       HashTable *fe_ht;
-       zend_object_iterator *iter = NULL;
-       zend_class_entry *ce = NULL;
-       zend_bool is_empty = 0;
-
-       SAVE_OPLINE();
-
-       if ((IS_VAR == IS_CV || IS_VAR == IS_VAR) &&
-           (opline->extended_value & ZEND_FE_FETCH_BYREF)) {
-               array_ptr = array_ref = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-               ZVAL_DEREF(array_ptr);
-               if (Z_TYPE_P(array_ptr) == IS_ARRAY) {
-                       SEPARATE_ARRAY(array_ptr);
-                       if (!Z_ISREF_P(array_ref)) {
-                               ZVAL_NEW_REF(array_ref, array_ref);
-                               array_ptr = Z_REFVAL_P(array_ref);
-                       }
-                       if (Z_REFCOUNTED_P(array_ref)) Z_ADDREF_P(array_ref);
-               } else if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
-                       ce = Z_OBJCE_P(array_ptr);
-                       if (ce->get_iterator == NULL) {
-                               Z_ADDREF_P(array_ptr);
-                       }
-                       array_ref = array_ptr;
-               } else {
-                       if (Z_REFCOUNTED_P(array_ref)) Z_ADDREF_P(array_ref);
-               }
-       } else {
-               array_ptr = array_ref = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-               ZVAL_DEREF(array_ptr);
-               if (IS_VAR == IS_TMP_VAR) {
-                       ZVAL_COPY_VALUE(&tmp, array_ptr);
-                       if (Z_OPT_IMMUTABLE_P(&tmp)) {
-                               zval_copy_ctor_func(&tmp);
-                       }
-                       array_ref = array_ptr = &tmp;
-                       if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
-                               ce = Z_OBJCE_P(array_ptr);
-                               if (ce && ce->get_iterator) {
-                                       Z_DELREF_P(array_ref);
-                               }
-                       }
-               } else if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
-                       ce = Z_OBJCE_P(array_ptr);
-                       if (!ce->get_iterator) {
-                               if (IS_VAR == IS_CV) {
-                                       Z_ADDREF_P(array_ref);
-                               }
-                       }
-               } else if (Z_IMMUTABLE_P(array_ref)) {
-                       if (IS_VAR == IS_CV) {
-                               zval_copy_ctor_func(array_ref);
-                               Z_ADDREF_P(array_ref);
-                       } else {
-                               ZVAL_COPY_VALUE(&tmp, array_ref);
-                               zval_copy_ctor_func(&tmp);
-                               array_ptr = array_ref = &tmp;
-                       }
-               } else if (Z_REFCOUNTED_P(array_ref)) {
-                       if (IS_VAR == IS_CONST ||
-                                  (IS_VAR == IS_CV &&
-                                   !Z_ISREF_P(array_ref) &&
-                                   Z_REFCOUNT_P(array_ref) > 1) ||
-                                  (IS_VAR == IS_VAR &&
-                                   !Z_ISREF_P(array_ref) &&
-                                   Z_REFCOUNT_P(array_ref) > 2)) {
-                               if (IS_VAR == IS_VAR) {
-                                       Z_DELREF_P(array_ref);
-                               }
-                               ZVAL_DUP(&tmp, array_ref);
-                               array_ptr = array_ref = &tmp;
-                       } else if (IS_VAR == IS_CV || IS_VAR == IS_VAR) {
-                               if (Z_ISREF_P(array_ref) && Z_REFCOUNT_P(array_ref) == 1) {
-                                       ZVAL_UNREF(array_ref);
-                                       array_ptr = array_ref;
-                               }
-                               if (Z_IMMUTABLE_P(array_ptr)) {
-                                       zval_copy_ctor_func(array_ptr);
-                               } else if (Z_ISREF_P(array_ref) &&
-                                          Z_COPYABLE_P(array_ptr) &&
-                                          Z_REFCOUNT_P(array_ptr) > 1) {
-                                       Z_DELREF_P(array_ptr);
-                                       zval_copy_ctor_func(array_ptr);
-                               }
-                               if (IS_VAR == IS_CV) {
-                                       Z_ADDREF_P(array_ref);
-                               }
-                       }
-               }
-       }
-
-       if (ce && ce->get_iterator) {
-               iter = ce->get_iterator(ce, array_ptr, opline->extended_value & ZEND_FE_FETCH_BYREF TSRMLS_CC);
-
-               if (IS_VAR == IS_VAR && !(opline->extended_value & ZEND_FE_FETCH_BYREF)) {
-                       zval_ptr_dtor_nogc(free_op1);
-               }
-               if (iter && EXPECTED(EG(exception) == NULL)) {
-                       ZVAL_OBJ(&iterator, &iter->std);
-                       array_ptr = array_ref = &iterator;
-               } else {
-                       if (IS_VAR == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
-                               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-                       }
-                       if (!EG(exception)) {
-                               zend_throw_exception_ex(NULL, 0 TSRMLS_CC, "Object of type %s did not create an Iterator", ce->name->val);
-                       }
-                       zend_throw_exception_internal(NULL TSRMLS_CC);
-                       HANDLE_EXCEPTION();
-               }
-       }
-
-       ZVAL_COPY_VALUE(EX_VAR(opline->result.var), array_ref);
-
-       if (iter) {
-               iter->index = 0;
-               if (iter->funcs->rewind) {
-                       iter->funcs->rewind(iter TSRMLS_CC);
-                       if (UNEXPECTED(EG(exception) != NULL)) {
-                               zval_ptr_dtor(array_ref);
-                               if (IS_VAR == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
-                                       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-                               }
-                               HANDLE_EXCEPTION();
-                       }
-               }
-               is_empty = iter->funcs->valid(iter TSRMLS_CC) != SUCCESS;
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       zval_ptr_dtor(array_ref);
-                       if (IS_VAR == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
-                               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-                       }
-                       HANDLE_EXCEPTION();
-               }
-               iter->index = -1; /* will be set to 0 before using next handler */
-       } else if ((fe_ht = HASH_OF(array_ptr)) != NULL) {
-               HashPointer *ptr = (HashPointer*)EX_VAR((opline+2)->op1.var);
-               HashPosition pos = 0;
-               Bucket *p;
-
-               while (1) {
-                       if (pos >= fe_ht->nNumUsed) {
-                               is_empty = 1;
-                               if (IS_VAR == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
-                                       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-                               }
-                               ZEND_VM_JMP(opline->op2.jmp_addr);
-                       }
-                       p = fe_ht->arData + pos;
-                       if (Z_TYPE(p->val) == IS_UNDEF ||
-                           (Z_TYPE(p->val) == IS_INDIRECT &&
-                            Z_TYPE_P(Z_INDIRECT(p->val)) == IS_UNDEF)) {
-                               pos++;
-                               continue;
-                       }
-                       if (!ce ||
-                           !p->key ||
-                           zend_check_property_access(Z_OBJ_P(array_ptr), p->key TSRMLS_CC) == SUCCESS) {
-                               break;
-                       }
-                       pos++;
-               }
-               fe_ht->nInternalPointer = pos;
-               ptr->pos = pos;
-               ptr->ht = fe_ht;
-               ptr->h = fe_ht->arData[pos].h;
-               ptr->key = fe_ht->arData[pos].key;
-               is_empty = 0;
-       } else {
-               zend_error(E_WARNING, "Invalid argument supplied for foreach()");
-               is_empty = 1;
-       }
-
-       if (IS_VAR == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
-               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       }
-       if (is_empty) {
-               ZEND_VM_JMP(opline->op2.jmp_addr);
-       } else {
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_FE_FETCH_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       zval *array, *array_ref;
-       zval *value;
-       HashTable *fe_ht;
-       HashPointer *ptr;
-       HashPosition pos;
-       Bucket *p;
-
-       array = array_ref = EX_VAR(opline->op1.var);
-       if (Z_ISREF_P(array)) {
-               array = Z_REFVAL_P(array);
-               // TODO: referenced value might be changed to different array ???
-               if (Z_IMMUTABLE_P(array)) {
-                       zval_copy_ctor_func(array);
-               }
-       }
-
-       SAVE_OPLINE();
-
-       if (EXPECTED(Z_TYPE_P(array) == IS_ARRAY)) {
-               fe_ht = Z_ARRVAL_P(array);
-               ptr = (HashPointer*)EX_VAR((opline+1)->op1.var);
-               pos = ptr->pos;
-               if (UNEXPECTED(pos == INVALID_IDX)) {
-                       /* reached end of iteration */
-                       ZEND_VM_JMP(opline->op2.jmp_addr);
-               } else if (UNEXPECTED(ptr->ht != fe_ht)) {
-                       ptr->ht = fe_ht;
-                       pos = 0;
-               } else if (UNEXPECTED(fe_ht->nInternalPointer != ptr->pos)) {
-                       if (fe_ht->u.flags & HASH_FLAG_PACKED) {
-                               pos = ptr->h;
-                       } else {
-                               pos = fe_ht->arHash[ptr->h & fe_ht->nTableMask];
-                               while (1) {
-                                       if (pos == INVALID_IDX) {
-                                               pos = fe_ht->nInternalPointer;
-                                               break;
-                                       } else if (fe_ht->arData[pos].h == ptr->h && fe_ht->arData[pos].key == ptr->key) {
-                                               break;
-                                       }
-                                       pos = Z_NEXT(fe_ht->arData[pos].val);
-                               }
-                       }
-               }
-               while (1) {
-                       if (UNEXPECTED(pos >= fe_ht->nNumUsed)) {
-                               /* reached end of iteration */
-                               ZEND_VM_JMP(opline->op2.jmp_addr);
-                       }
-                       p = fe_ht->arData + pos;
-                       value = &p->val;
-                       if (UNEXPECTED(Z_TYPE_P(value) == IS_UNDEF)) {
-                               pos++;
-                               continue;
-                       } else if (UNEXPECTED(Z_TYPE_P(value) == IS_INDIRECT)) {
-                               value = Z_INDIRECT_P(value);
-                               if (UNEXPECTED(Z_TYPE_P(value) == IS_UNDEF)) {
-                                       pos++;
-                                       continue;
-                               }
-                       }
-                       if (opline->extended_value & ZEND_FE_FETCH_BYREF) {
-                               ZVAL_MAKE_REF(value);
-                               Z_ADDREF_P(value);
-                               ZVAL_REF(EX_VAR(opline->result.var), Z_REF_P(value));
-                       } else {
-                               ZVAL_COPY(EX_VAR(opline->result.var), value);
-                       }
-                       if (opline->extended_value & ZEND_FE_FETCH_WITH_KEY) {
-                               if (!p->key) {
-                                       ZVAL_LONG(EX_VAR((opline+1)->result.var), p->h);
-                               } else {
-                                       ZVAL_STR_COPY(EX_VAR((opline+1)->result.var), p->key);
-                               }
-                       }
-                       break;
-               }
-               do {
-                       pos++;
-                       if (pos >= fe_ht->nNumUsed) {
-                               fe_ht->nInternalPointer = ptr->pos = INVALID_IDX;
-                               ZEND_VM_INC_OPCODE();
-                               ZEND_VM_NEXT_OPCODE();
-                       }
-                       p = fe_ht->arData + pos;
-               } while (Z_TYPE(p->val) == IS_UNDEF ||
-                            (Z_TYPE(p->val) == IS_INDIRECT &&
-                             Z_TYPE_P(Z_INDIRECT(p->val)) == IS_UNDEF));
-               fe_ht->nInternalPointer = ptr->pos = pos;
-               ptr->h = fe_ht->arData[pos].h;
-               ptr->key = fe_ht->arData[pos].key;
-               ZEND_VM_INC_OPCODE();
-               ZEND_VM_NEXT_OPCODE();
-       } else if (EXPECTED(Z_TYPE_P(array) == IS_OBJECT)) {
-               zend_object_iterator *iter;
-
-               if ((iter = zend_iterator_unwrap(array TSRMLS_CC)) == NULL) {
-                       /* plain object */
-                       zend_object *zobj = Z_OBJ_P(array);
-
-                       fe_ht = Z_OBJPROP_P(array);
-                       ptr = (HashPointer*)EX_VAR((opline+1)->op1.var);
-                       pos = ptr->pos;
-                       if (pos == INVALID_IDX) {
-                               /* reached end of iteration */
-                               ZEND_VM_JMP(opline->op2.jmp_addr);
-                       } else if (UNEXPECTED(ptr->ht != fe_ht)) {
-                               ptr->ht = fe_ht;
-                               pos = 0;
-                       } else if (UNEXPECTED(fe_ht->nInternalPointer != ptr->pos)) {
-                               if (fe_ht->u.flags & HASH_FLAG_PACKED) {
-                                       pos = ptr->h;
-                               } else {
-                                       pos = fe_ht->arHash[ptr->h & fe_ht->nTableMask];
-                                       while (1) {
-                                               if (pos == INVALID_IDX) {
-                                                       pos = fe_ht->nInternalPointer;
-                                                       break;
-                                               } else if (fe_ht->arData[pos].h == ptr->h && fe_ht->arData[pos].key == ptr->key) {
-                                                       break;
-                                               }
-                                               pos = Z_NEXT(fe_ht->arData[pos].val);
-                                       }
-                               }
-                       }
-                       while (1) {
-                               if (UNEXPECTED(pos >= fe_ht->nNumUsed)) {
-                                       /* reached end of iteration */
-                                       ZEND_VM_JMP(opline->op2.jmp_addr);
-                               }
-
-                               p = fe_ht->arData + pos;
-                               value = &p->val;
-                               if (UNEXPECTED(Z_TYPE_P(value) == IS_UNDEF)) {
-                                       pos++;
-                                       continue;
-                               } else if (UNEXPECTED(Z_TYPE_P(value) == IS_INDIRECT)) {
-                                       value = Z_INDIRECT_P(value);
-                                       if (UNEXPECTED(Z_TYPE_P(value) == IS_UNDEF)) {
-                                               pos++;
-                                               continue;
-                                       }
-                               }
-
-                               if (UNEXPECTED(!p->key)) {
-                                       if (opline->extended_value & ZEND_FE_FETCH_WITH_KEY) {
-                                               ZVAL_LONG(EX_VAR((opline+1)->result.var), p->h);
-                                       }
-                                       break;
-                               } else if (zend_check_property_access(zobj, p->key TSRMLS_CC) == SUCCESS) {
-                                       if (opline->extended_value & ZEND_FE_FETCH_WITH_KEY) {
-                                               if (p->key->val[0]) {
-                                                       ZVAL_STR_COPY(EX_VAR((opline+1)->result.var), p->key);
-                                               } else {
-                                                       const char *class_name, *prop_name;
-                                                       size_t prop_name_len;
-                                                       zend_unmangle_property_name_ex(
-                                                               p->key, &class_name, &prop_name, &prop_name_len);
-                                                       ZVAL_STRINGL(EX_VAR((opline+1)->result.var), prop_name, prop_name_len);
-                                               }
-                                       }
-                                       break;
-                               }
-                               pos++;
-                       }
-                       if (opline->extended_value & ZEND_FE_FETCH_BYREF) {
-                               ZVAL_MAKE_REF(value);
-                               Z_ADDREF_P(value);
-                               ZVAL_REF(EX_VAR(opline->result.var), Z_REF_P(value));
-                       } else {
-                               ZVAL_COPY(EX_VAR(opline->result.var), value);
-                       }
-                       do {
-                               pos++;
-                               if (pos >= fe_ht->nNumUsed) {
-                                       fe_ht->nInternalPointer = ptr->pos = INVALID_IDX;
-                                       ZEND_VM_INC_OPCODE();
-                                       ZEND_VM_NEXT_OPCODE();
-                               }
-                               p = fe_ht->arData + pos;
-                       } while (Z_TYPE(p->val) == IS_UNDEF ||
-                                    (Z_TYPE(p->val) == IS_INDIRECT &&
-                                     Z_TYPE_P(Z_INDIRECT(p->val)) == IS_UNDEF) ||
-                                    (EXPECTED(p->key != NULL) &&
-                                     zend_check_property_access(zobj, p->key TSRMLS_CC) == FAILURE));
-                       fe_ht->nInternalPointer = ptr->pos = pos;
-                       ptr->h = fe_ht->arData[pos].h;
-                       ptr->key = fe_ht->arData[pos].key;
-                       ZEND_VM_INC_OPCODE();
-                       ZEND_VM_NEXT_OPCODE();
-               } else {
-                       /* !iter happens from exception */
-                       if (iter && ++iter->index > 0) {
-                               /* This could cause an endless loop if index becomes zero again.
-                                * In case that ever happens we need an additional flag. */
-                               iter->funcs->move_forward(iter TSRMLS_CC);
-                               if (UNEXPECTED(EG(exception) != NULL)) {
-                                       zval_ptr_dtor(array_ref);
-                                       HANDLE_EXCEPTION();
-                               }
-                       }
-                       /* If index is zero we come from FE_RESET and checked valid() already. */
-                       if (!iter || (iter->index > 0 && iter->funcs->valid(iter TSRMLS_CC) == FAILURE)) {
-                               /* reached end of iteration */
-                               if (UNEXPECTED(EG(exception) != NULL)) {
-                                       zval_ptr_dtor(array_ref);
-                                       HANDLE_EXCEPTION();
-                               }
-                               ZEND_VM_JMP(opline->op2.jmp_addr);
-                       }
-                       value = iter->funcs->get_current_data(iter TSRMLS_CC);
-                       if (UNEXPECTED(EG(exception) != NULL)) {
-                               zval_ptr_dtor(array_ref);
-                               HANDLE_EXCEPTION();
-                       }
-                       if (!value) {
-                               /* failure in get_current_data */
-                               ZEND_VM_JMP(opline->op2.jmp_addr);
-                       }
-                       if (opline->extended_value & ZEND_FE_FETCH_BYREF) {
-                               ZVAL_MAKE_REF(value);
-                               Z_ADDREF_P(value);
-                               ZVAL_REF(EX_VAR(opline->result.var), Z_REF_P(value));
-                       } else {
-                               ZVAL_COPY(EX_VAR(opline->result.var), value);
-                       }
-                       if (opline->extended_value & ZEND_FE_FETCH_WITH_KEY) {
-                               if (iter->funcs->get_current_key) {
-                                       iter->funcs->get_current_key(iter, EX_VAR((opline+1)->result.var) TSRMLS_CC);
-                                       if (UNEXPECTED(EG(exception) != NULL)) {
-                                               zval_ptr_dtor(array_ref);
-                                               HANDLE_EXCEPTION();
-                                       }
-                               } else {
-                                       ZVAL_LONG(EX_VAR((opline+1)->result.var), iter->index);
-                               }
-                       }
-                       ZEND_VM_INC_OPCODE();
-                       ZEND_VM_NEXT_OPCODE();
-               }
-       } else {
-               zend_error(E_WARNING, "Invalid argument supplied for foreach()");
-               ZEND_VM_JMP(opline->op2.jmp_addr);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_EXIT_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-#if 0 || (IS_VAR != IS_UNUSED)
-       USE_OPLINE
-
-       SAVE_OPLINE();
-       if (IS_VAR != IS_UNUSED) {
-               zend_free_op free_op1;
-               zval *ptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-               if (Z_TYPE_P(ptr) == IS_LONG) {
-                       EG(exit_status) = Z_LVAL_P(ptr);
-               } else {
-                       zend_print_variable(ptr TSRMLS_CC);
-               }
-               zval_ptr_dtor_nogc(free_op1);
-       }
-#endif
-       zend_bailout();
-       ZEND_VM_NEXT_OPCODE(); /* Never reached */
-}
-
-static int ZEND_FASTCALL  ZEND_JMP_SET_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *value;
-       int is_ref = 0;
-
-       SAVE_OPLINE();
-       value = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && Z_ISREF_P(value)) {
-               is_ref = 1;
-               value = Z_REFVAL_P(value);
-       }
-       if (i_zend_is_true(value TSRMLS_CC)) {
-               ZVAL_COPY_VALUE(EX_VAR(opline->result.var), value);
-               if (IS_VAR == IS_CONST) {
-                       if (UNEXPECTED(Z_OPT_COPYABLE_P(value))) {
-                               zval_copy_ctor_func(EX_VAR(opline->result.var));
-                       }
-               } else if (IS_VAR == IS_CV) {
-                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
-               } else if (IS_VAR == IS_VAR && is_ref) {
-                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
-                       zval_ptr_dtor_nogc(free_op1);
-               }
-               ZEND_VM_JMP(opline->op2.jmp_addr);
-       }
-
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_COALESCE_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *value;
-       int is_ref = 0;
-
-       SAVE_OPLINE();
-       value = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && Z_ISREF_P(value)) {
-               is_ref = 1;
-               value = Z_REFVAL_P(value);
-       }
-
-       if (Z_TYPE_P(value) > IS_NULL) {
-               ZVAL_COPY_VALUE(EX_VAR(opline->result.var), value);
-               if (IS_VAR == IS_CONST) {
-                       if (UNEXPECTED(Z_OPT_COPYABLE_P(value))) {
-                               zval_copy_ctor_func(EX_VAR(opline->result.var));
-                       }
-               } else if (IS_VAR == IS_CV) {
-                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
-               } else if (IS_VAR == IS_VAR && is_ref) {
-                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
-                       zval_ptr_dtor_nogc(free_op1);
-               }
-               ZEND_VM_JMP(opline->op2.jmp_addr);
-       }
-
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_QM_ASSIGN_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *value;
-
-       SAVE_OPLINE();
-       value = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && Z_ISREF_P(value)) {
-               ZVAL_COPY(EX_VAR(opline->result.var), Z_REFVAL_P(value));
-               zval_ptr_dtor_nogc(free_op1);
-       } else {
-               ZVAL_COPY_VALUE(EX_VAR(opline->result.var), value);
-               if (IS_VAR == IS_CONST) {
-                       if (UNEXPECTED(Z_OPT_COPYABLE_P(value))) {
-                               zval_copy_ctor_func(EX_VAR(opline->result.var));
-                       }
-               } else if (IS_VAR == IS_CV) {
-                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
-               }
-       }
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_STRLEN_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *value;
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-       value = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-       if (EXPECTED(Z_TYPE_P(value) == IS_STRING)) {
-               ZVAL_LONG(EX_VAR(opline->result.var), Z_STRLEN_P(value));
-       } else {
-               if (Z_TYPE_P(value) < IS_TRUE) {
-                       ZVAL_LONG(EX_VAR(opline->result.var), 0);
-               } else if (Z_TYPE_P(value) == IS_TRUE) {
-                       ZVAL_LONG(EX_VAR(opline->result.var), 1);
-               } else if (Z_TYPE_P(value) <= IS_DOUBLE) {
-                       zend_string *str = zval_get_string(value);
-                       ZVAL_LONG(EX_VAR(opline->result.var), str->len);
-                       zend_string_release(str);
-               } else if (Z_TYPE_P(value) == IS_OBJECT) {
-                       zend_string *str;
-                       zval tmp;
-
-                       ZVAL_COPY(&tmp, value);
-                       if (parse_arg_object_to_str(&tmp, &str, IS_STRING TSRMLS_CC) == FAILURE) {
-                               goto strlen_error;
-                       }
-                       ZVAL_LONG(EX_VAR(opline->result.var), str->len);
-                       zval_dtor(&tmp);
-               } else {
-strlen_error:
-                       zend_error(E_WARNING, "strlen() expects parameter 1 to be string, %s given", zend_get_type_by_const(Z_TYPE_P(value)));
-                       ZVAL_NULL(EX_VAR(opline->result.var));
-               }
-       }
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_TYPE_CHECK_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *value;
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-       value = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-       switch (opline->extended_value) {
-               case IS_NULL:
-               case IS_LONG:
-               case IS_DOUBLE:
-               case IS_STRING:
-               case IS_ARRAY:
-                       ZVAL_BOOL(EX_VAR(opline->result.var), Z_TYPE_P(value) == opline->extended_value);
-                       break;
-               case _IS_BOOL:
-                       ZVAL_BOOL(EX_VAR(opline->result.var), Z_TYPE_P(value) == IS_TRUE || Z_TYPE_P(value) == IS_FALSE);
-                       break;
-               case IS_OBJECT:
-                       if (Z_TYPE_P(value) == opline->extended_value) {
-                               zend_class_entry *ce = Z_OBJCE_P(value);
-                               if (ce->name->len == sizeof("__PHP_Incomplete_Class") - 1
-                                               && !strncmp(ce->name->val, "__PHP_Incomplete_Class", ce->name->len)) {
-                                       ZVAL_FALSE(EX_VAR(opline->result.var));
-                               } else {
-                                       ZVAL_TRUE(EX_VAR(opline->result.var));
-                               }
-                       } else {
-                               ZVAL_FALSE(EX_VAR(opline->result.var));
-                       }
-                       break;
-               case IS_RESOURCE:
-                       if (Z_TYPE_P(value) == opline->extended_value) {
-                               const char *type_name = zend_rsrc_list_get_rsrc_type(Z_RES_P(value) TSRMLS_CC);
-                               ZVAL_BOOL(EX_VAR(opline->result.var), type_name != NULL);
-                       } else {
-                               ZVAL_FALSE(EX_VAR(opline->result.var));
-                       }
-                       break;
-               EMPTY_SWITCH_DEFAULT_CASE()
-       }
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_MOD_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-       fast_mod_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               opline->op2.zv TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_SL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-       shift_left_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               opline->op2.zv TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_SR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-       shift_right_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               opline->op2.zv TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-       concat_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               opline->op2.zv TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-       fast_is_identical_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               opline->op2.zv TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *result = EX_VAR(opline->result.var);
-
-       SAVE_OPLINE();
-       fast_is_not_identical_function(result,
-               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               opline->op2.zv TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-       bitwise_or_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               opline->op2.zv TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-       bitwise_and_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               opline->op2.zv TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-       bitwise_xor_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               opline->op2.zv TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-       boolean_xor_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               opline->op2.zv TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1, free_op_data1;
-       zval *object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-       zval *property = opline->op2.zv;
-       zval *value;
-       zval *zptr;
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
-       }
-
-       if (IS_VAR != IS_UNUSED) {
-               object = make_real_object(object TSRMLS_CC);
-       }
-
-       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-
-       if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
-               zend_error(E_WARNING, "Attempt to assign property of non-object");
-
-               FREE_OP(free_op_data1);
-
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
-               }
-       } else {
-               /* here we are sure we are dealing with an object */
-               if (opline->extended_value == ZEND_ASSIGN_OBJ
-                       && EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-                       && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
-
-                       ZVAL_DEREF(zptr);
-                       SEPARATE_ZVAL_NOREF(zptr);
-
-                       binary_op(zptr, zptr, value TSRMLS_CC);
-                       if (RETURN_VALUE_USED(opline)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), zptr);
-                       }
-               } else {
-                       zval *z = NULL;
-                       zval rv;
-
-                       if (opline->extended_value == ZEND_ASSIGN_OBJ) {
-                               if (Z_OBJ_HT_P(object)->read_property) {
-                                       z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
-                               }
-                       } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
-                               if (Z_OBJ_HT_P(object)->read_dimension) {
-                                       z = Z_OBJ_HT_P(object)->read_dimension(object, property, BP_VAR_R, &rv TSRMLS_CC);
-                               }
-                       }
-                       if (z) {
-                               if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
-                                       zval rv;
-                                       zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
-
-                                       if (Z_REFCOUNT_P(z) == 0) {
-                                               zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
-                                       }
-                                       ZVAL_COPY_VALUE(z, value);
-                               }
-//???                          if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
-                               SEPARATE_ZVAL_IF_NOT_REF(z);
-                               binary_op(z, z, value TSRMLS_CC);
-                               if (opline->extended_value == ZEND_ASSIGN_OBJ) {
-                                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
-                               } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
-                                       Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
-                               }
-                               if (RETURN_VALUE_USED(opline)) {
-                                       ZVAL_COPY(EX_VAR(opline->result.var), z);
-                               }
-                               zval_ptr_dtor(z);
-                       } else {
-                               zend_error(E_WARNING, "Attempt to assign property of non-object");
-                               if (RETURN_VALUE_USED(opline)) {
-                                       ZVAL_NULL(EX_VAR(opline->result.var));
-                               }
-                       }
-               }
-
-               FREE_OP(free_op_data1);
-       }
-
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       /* assign_obj has two opcodes! */
-       CHECK_EXCEPTION();
-       ZEND_VM_INC_OPCODE();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1, free_op_data1;
-       zval *var_ptr, rv;
-       zval *value, *container;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-       }
-       if (IS_VAR != IS_UNUSED) {
-               ZVAL_DEREF(container);
-       }
-       if (IS_VAR == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (IS_VAR == IS_VAR && !(free_op1 != NULL)) {
-                       Z_ADDREF_P(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
-               }
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else {
-               zval *dim = opline->op2.zv;
-
-               zend_fetch_dimension_address_RW(&rv, container, dim, IS_CONST TSRMLS_CC);
-               value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-               ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
-               var_ptr = Z_INDIRECT(rv);
-       }
-
-       if (UNEXPECTED(var_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
-       }
-
-       if (UNEXPECTED(var_ptr == &EG(error_zval))) {
-               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
-               }
-       } else {
-               ZVAL_DEREF(var_ptr);
-               SEPARATE_ZVAL_NOREF(var_ptr);
-
-               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
-
-               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
-               }
-       }
-
-       FREE_OP(free_op_data1);
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       CHECK_EXCEPTION();
-       ZEND_VM_INC_OPCODE();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *var_ptr;
-       zval *value;
-
-       SAVE_OPLINE();
-       value = opline->op2.zv;
-       var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
-       }
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
-               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
-               }
-       } else {
-               ZVAL_DEREF(var_ptr);
-               SEPARATE_ZVAL_NOREF(var_ptr);
-
-               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
-
-               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
-               }
-       }
-
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_ADD_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_SUB_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_MUL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_DIV_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_MOD_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_SL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_SR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_CONCAT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_OR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_AND_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *object;
-       zval *property;
-       zval *retval;
-       zval *zptr;
-
-       SAVE_OPLINE();
-       object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-       property = opline->op2.zv;
-       retval = EX_VAR(opline->result.var);
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
-       }
-
-       if (IS_VAR != IS_UNUSED) {
-               object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
-       }
-
-       if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
-               zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(retval);
-               }
-               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
-
-       /* here we are sure we are dealing with an object */
-
-       if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
-
-               ZVAL_DEREF(zptr);
-               SEPARATE_ZVAL_NOREF(zptr);
-
-               incdec_op(zptr);
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_COPY(retval, zptr);
-               }
-       } else {
-               zval rv;
-
-               if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
-                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
-
-                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
-                               zval rv;
-                               zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
-
-                               if (Z_REFCOUNT_P(z) == 0) {
-                                       zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
-                               }
-                               ZVAL_COPY_VALUE(z, value);
-                       }
-                       if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
-                       SEPARATE_ZVAL_IF_NOT_REF(z);
-                       incdec_op(z);
-                       ZVAL_COPY_VALUE(retval, z);
-                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
-                       SELECTIVE_PZVAL_LOCK(retval, opline);
-                       zval_ptr_dtor(z);
-               } else {
-                       zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-                       if (RETURN_VALUE_USED(opline)) {
-                               ZVAL_NULL(retval);
-                       }
-               }
-       }
-
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_PRE_INC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_pre_incdec_property_helper_SPEC_VAR_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_pre_incdec_property_helper_SPEC_VAR_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *object;
-       zval *property;
-       zval *retval;
-       zval *zptr;
-
-       SAVE_OPLINE();
-       object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-       property = opline->op2.zv;
-       retval = EX_VAR(opline->result.var);
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
-       }
-
-       if (IS_VAR != IS_UNUSED) {
-               object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
-       }
-
-       if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
-               zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-
-               ZVAL_NULL(retval);
-               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
-
-       /* here we are sure we are dealing with an object */
-
-       if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
-
-               ZVAL_DEREF(zptr);
-               ZVAL_COPY_VALUE(retval, zptr);
-               zval_opt_copy_ctor(zptr);
-
-               incdec_op(zptr);
-       } else {
-               if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
-                       zval rv;
-                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
-                       zval z_copy;
-
-                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
-                               zval rv;
-                               zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
-
-                               if (Z_REFCOUNT_P(z) == 0) {
-                                       zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
-                               }
-                               ZVAL_COPY_VALUE(z, value);
-                       }
-                       ZVAL_DUP(retval, z);
-                       ZVAL_DUP(&z_copy, z);
-                       incdec_op(&z_copy);
-                       if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
-                       Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
-                       zval_ptr_dtor(&z_copy);
-                       zval_ptr_dtor(z);
-               } else {
-                       zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-                       ZVAL_NULL(retval);
-               }
-       }
-
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_POST_INC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_post_incdec_property_helper_SPEC_VAR_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_post_incdec_property_helper_SPEC_VAR_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_VAR_CONST(int type, ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *varname;
-       zval *retval;
-       zend_string *name;
-       HashTable *target_symbol_table;
-
-       SAVE_OPLINE();
-       varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR == IS_CONST) {
-               name = Z_STR_P(varname);
-       } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
-               name = Z_STR_P(varname);
-               zend_string_addref(name);
-       } else {
-               name = zval_get_string(varname);
-       }
-
-       if (IS_CONST != IS_UNUSED) {
-               zend_class_entry *ce;
-
-               if (IS_CONST == IS_CONST) {
-                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                       } else {
-                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                               if (UNEXPECTED(ce == NULL)) {
-                                       if (IS_VAR != IS_CONST) {
-                                               zend_string_release(name);
-                                       }
-                                       zval_ptr_dtor_nogc(free_op1);
-                                       CHECK_EXCEPTION();
-                                       ZEND_VM_NEXT_OPCODE();
-                               }
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
-                       }
-               } else {
-                       ce = Z_CE_P(EX_VAR(opline->op2.var));
-               }
-               retval = zend_std_get_static_property(ce, name, 0, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op1);
-       } else {
-               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-               retval = zend_hash_find(target_symbol_table, name);
-               if (retval == NULL) {
-                       switch (type) {
-                               case BP_VAR_R:
-                               case BP_VAR_UNSET:
-                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                       /* break missing intentionally */
-                               case BP_VAR_IS:
-                                       retval = &EG(uninitialized_zval);
-                                       break;
-                               case BP_VAR_RW:
-                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                       /* break missing intentionally */
-                               case BP_VAR_W:
-                                       retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
-                                       break;
-                               EMPTY_SWITCH_DEFAULT_CASE()
-                       }
-               /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
-               } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
-                       retval = Z_INDIRECT_P(retval);
-                       if (Z_TYPE_P(retval) == IS_UNDEF) {
-                               switch (type) {
-                                       case BP_VAR_R:
-                                       case BP_VAR_UNSET:
-                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                               /* break missing intentionally */
-                                       case BP_VAR_IS:
-                                               retval = &EG(uninitialized_zval);
-                                               break;
-                                       case BP_VAR_RW:
-                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                               /* break missing intentionally */
-                                       case BP_VAR_W:
-                                               ZVAL_NULL(retval);
-                                               break;
-                                       EMPTY_SWITCH_DEFAULT_CASE()
-                               }
-                       }
-               }
-               if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
-                       if (Z_CONSTANT_P(retval)) {
-                               zval_update_constant(retval, 1 TSRMLS_CC);
-                       }
-               } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
-                       zval_ptr_dtor_nogc(free_op1);
-               }
-       }
-
-       if (IS_VAR != IS_CONST) {
-               zend_string_release(name);
-       }
-
-       ZEND_ASSERT(retval != NULL);
-       if (type == BP_VAR_R || type == BP_VAR_IS) {
-               if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
-                       ZVAL_UNREF(retval);
-               }
-               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-       } else {
-               ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
-       }
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_R_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_VAR_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_W_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_VAR_CONST(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_RW_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_VAR_CONST(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_FUNC_ARG_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-               return zend_fetch_var_address_helper_SPEC_VAR_CONST(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else {
-               return zend_fetch_var_address_helper_SPEC_VAR_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_UNSET_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_VAR_CONST(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_IS_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_VAR_CONST(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *container;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-       zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
-
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *container;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-       }
-       ZVAL_DEREF(container);
-       zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
-
-       if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-       }
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *container;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-       }
-       ZVAL_DEREF(container);
-       zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
-
-       if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-       }
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *container;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-       zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
-
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *container;
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-        if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
-            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
-        }
-               container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-               }
-               ZVAL_DEREF(container);
-               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
-               if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
-                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-               }
-
-               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       } else {
-               if (IS_CONST == IS_UNUSED) {
-                       zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
-               }
-               container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
-
-               zval_ptr_dtor_nogc(free_op1);
-       }
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_UNSET_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *container;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-       }
-       ZVAL_DEREF(container);
-       zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
-
-       if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-       }
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *container;
-
-       zval *offset;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-       offset  = opline->op2.zv;
-
-       if ((IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
-           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
-               zend_error(E_NOTICE, "Trying to get property of non-object");
-               ZVAL_NULL(EX_VAR(opline->result.var));
-       } else {
-               zval *retval;
-
-               /* here we are sure we are dealing with an object */
-               do {
-                       if (IS_CONST == IS_CONST &&
-                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
-                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
-                               zend_object *zobj = Z_OBJ_P(container);
-
-                               if (EXPECTED(prop_info)) {
-                                       retval = OBJ_PROP(zobj, prop_info->offset);
-                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               } else if (EXPECTED(zobj->properties != NULL)) {
-                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
-                                       if (EXPECTED(retval)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               }
-                       }
-
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
-
-                       if (retval != EX_VAR(opline->result.var)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                       }
-               } while (0);
-       }
-
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *property;
-       zval *container;
-
-       SAVE_OPLINE();
-       property = opline->op2.zv;
-
-       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
-       }
-
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
-
-       if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-       }
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *property;
-       zval *container;
-
-       SAVE_OPLINE();
-       property = opline->op2.zv;
-       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
-       }
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
-
-       if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-       }
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *container;
-
-       zval *offset;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-       offset  = opline->op2.zv;
-
-       if ((IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
-           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
-               ZVAL_NULL(EX_VAR(opline->result.var));
-       } else {
-               zval *retval;
-
-               /* here we are sure we are dealing with an object */
-               do {
-                       if (IS_CONST == IS_CONST &&
-                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
-                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
-                               zend_object *zobj = Z_OBJ_P(container);
-
-                               if (EXPECTED(prop_info)) {
-                                       retval = OBJ_PROP(zobj, prop_info->offset);
-                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               } else if (EXPECTED(zobj->properties != NULL)) {
-                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
-                                       if (EXPECTED(retval)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               }
-                       }
-
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
-
-                       if (retval != EX_VAR(opline->result.var)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                       }
-               } while (0);
-       }
-
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *container;
-
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-               /* Behave like FETCH_OBJ_W */
-               zend_free_op free_op1;
-               zval *property;
-
-               SAVE_OPLINE();
-               property = opline->op2.zv;
-               container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-        if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
-            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
-        }
-               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
-               }
-               zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
-
-               if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
-                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-               }
-               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       } else {
-               return ZEND_FETCH_OBJ_R_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *container, *property;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-       property = opline->op2.zv;
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
-       }
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
-
-       if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-       }
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_LIST_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *container;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
-       if (EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
-
-               zval *value = zend_fetch_dimension_address_inner(Z_ARRVAL_P(container), opline->op2.zv, IS_CONST, BP_VAR_R TSRMLS_CC);
-
-               ZVAL_COPY(EX_VAR(opline->result.var), value);
-       } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT) &&
-                  EXPECTED(Z_OBJ_HT_P(container)->read_dimension)) {
-               zval *result = EX_VAR(opline->result.var);
-               zval *retval = Z_OBJ_HT_P(container)->read_dimension(container, opline->op2.zv, BP_VAR_R, result TSRMLS_CC);
-
-               if (retval) {
-                       if (result != retval) {
-                               ZVAL_COPY(result, retval);
-                       }
-               } else {
-                       ZVAL_NULL(result);
-               }
-       } else {
-               ZVAL_NULL(EX_VAR(opline->result.var));
-       }
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *object;
-       zval *property_name;
-
-       SAVE_OPLINE();
-       object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-       property_name = opline->op2.zv;
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-       }
-       zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_VAR, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
-
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       /* assign_obj has two opcodes! */
-       CHECK_EXCEPTION();
-       ZEND_VM_INC_OPCODE();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *object_ptr;
-
-       SAVE_OPLINE();
-       object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-       }
-       ZVAL_DEREF(object_ptr);
-       if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
-
-               zval *property_name = opline->op2.zv;
-
-               zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_VAR, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
-
-       } else {
-               zend_free_op free_op_data1;
-               zval  rv;
-               zval *value;
-               zval *dim = opline->op2.zv;
-               zval *variable_ptr;
-
-               if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
-                   EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
-                       zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
-
-                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-                       zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
-                       FREE_OP(free_op_data1);
-               } else {
-                       zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_CONST TSRMLS_CC);
-
-                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-                       ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
-                       variable_ptr = Z_INDIRECT(rv);
-                       if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
-                               FREE_OP(free_op_data1);
-                               if (RETURN_VALUE_USED(opline)) {
-                                       ZVAL_NULL(EX_VAR(opline->result.var));
-                               }
-                       } else {
-                               value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
-                               if ((opline+1)->op1_type == IS_VAR) {
-                                       FREE_OP(free_op_data1);
-                               }
-                               if (RETURN_VALUE_USED(opline)) {
-                                       ZVAL_COPY(EX_VAR(opline->result.var), value);
-                               }
-                       }
-               }
-       }
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       /* assign_dim has two opcodes! */
-       CHECK_EXCEPTION();
-       ZEND_VM_INC_OPCODE();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *value;
-       zval *variable_ptr;
-
-       SAVE_OPLINE();
-       value = opline->op2.zv;
-       variable_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
-               if (IS_CONST == IS_TMP_VAR) {
-
-               }
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
-               }
-       } else {
-               value = zend_assign_to_variable(variable_ptr, value, IS_CONST TSRMLS_CC);
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_COPY(EX_VAR(opline->result.var), value);
-               }
-               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       }
-
-       /* zend_assign_to_variable() always takes care of op2, never free it! */
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *function_name;
-       zend_free_op free_op1;
-       zval *object;
-       zend_function *fbc;
-       zend_class_entry *called_scope;
-       zend_object *obj;
-
-       SAVE_OPLINE();
-
-       function_name = opline->op2.zv;
-
-       if (IS_CONST != IS_CONST &&
-           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       HANDLE_EXCEPTION();
-               }
-               zend_error_noreturn(E_ERROR, "Method name must be a string");
-       }
-
-       object = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
-               uint32_t nesting = 1;
-
-               if (UNEXPECTED(EG(exception) != NULL)) {
-
-                       HANDLE_EXCEPTION();
-               }
-
-               zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s",  Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
-
-               zval_ptr_dtor_nogc(free_op1);
-
-               if (EG(exception) != NULL) {
-                       HANDLE_EXCEPTION();
-               }
-
-               /* No exception raised: Skip over arguments until fcall opcode with correct
-                * nesting level. Return NULL (except when return value unused) */
-               do {
-                       opline++;
-                       if (opline->opcode == ZEND_INIT_FCALL ||
-                               opline->opcode == ZEND_INIT_FCALL_BY_NAME ||
-                               opline->opcode == ZEND_INIT_NS_FCALL_BY_NAME ||
-                               opline->opcode == ZEND_INIT_METHOD_CALL ||
-                               opline->opcode == ZEND_INIT_STATIC_METHOD_CALL ||
-                               opline->opcode == ZEND_INIT_USER_CALL ||
-                               opline->opcode == ZEND_NEW
-                       ) {
-                               nesting++;
-                       } else if (opline->opcode == ZEND_DO_FCALL) {
-                               nesting--;
-                       }
-               } while (nesting);
-
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
-               }
-
-               /* We've skipped EXT_FCALL_BEGIND, so also skip the ending opcode */
-               if ((opline + 1)->opcode == ZEND_EXT_FCALL_END) {
-                       opline++;
-               }
-               ZEND_VM_JMP(++opline);
-       }
-
-       obj = Z_OBJ_P(object);
-       called_scope = obj->ce;
-
-       if (IS_CONST != IS_CONST ||
-           EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
-           zend_object *orig_obj = obj;
-
-               if (UNEXPECTED(obj->handlers->get_method == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Object does not support method calls");
-               }
-
-               /* First, locate the function. */
-               fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_CONST == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
-               if (UNEXPECTED(fbc == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
-               }
-               if (IS_CONST == IS_CONST &&
-                   EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
-                   EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
-                   EXPECTED(obj == orig_obj)) {
-                       CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope, fbc);
-               }
-       }
-
-       if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_STATIC) != 0)) {
-               obj = NULL;
-       } else {
-               GC_REFCOUNT(obj)++; /* For $this pointer */
-       }
-
-       EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
-               fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
-
-       zval_ptr_dtor_nogc(free_op1);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *function_name;
-       zend_class_entry *ce;
-       zend_object *object;
-       zend_function *fbc;
-
-       SAVE_OPLINE();
-
-       if (IS_VAR == IS_CONST) {
-               /* no function found. try a static method in class */
-               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv))) {
-                       ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv));
-               } else {
-                       ce = zend_fetch_class_by_name(Z_STR_P(opline->op1.zv), opline->op1.zv + 1, ZEND_FETCH_CLASS_DEFAULT TSRMLS_CC);
-                       if (UNEXPECTED(EG(exception) != NULL)) {
-                               HANDLE_EXCEPTION();
-                       }
-                       if (UNEXPECTED(ce == NULL)) {
-                               zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
-                       }
-                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op1.zv), ce);
-               }
-       } else {
-               ce = Z_CE_P(EX_VAR(opline->op1.var));
-       }
-
-       if (IS_VAR == IS_CONST &&
-           IS_CONST == IS_CONST &&
-           CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-               fbc = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-       } else if (IS_VAR != IS_CONST &&
-                  IS_CONST == IS_CONST &&
-                  (fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce))) {
-               /* do nothing */
-       } else if (IS_CONST != IS_UNUSED) {
-
-
-               function_name = opline->op2.zv;
-               if (IS_CONST != IS_CONST) {
-                       if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
-                               if (UNEXPECTED(EG(exception) != NULL)) {
-                                       HANDLE_EXCEPTION();
-                               }
-                               zend_error_noreturn(E_ERROR, "Function name must be a string");
-                       }
-               }
-
-               if (ce->get_static_method) {
-                       fbc = ce->get_static_method(ce, Z_STR_P(function_name) TSRMLS_CC);
-               } else {
-                       fbc = zend_std_get_static_method(ce, Z_STR_P(function_name), ((IS_CONST == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
-               }
-               if (UNEXPECTED(fbc == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name->val, Z_STRVAL_P(function_name));
-               }
-               if (IS_CONST == IS_CONST &&
-                   EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
-                   EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0)) {
-                       if (IS_VAR == IS_CONST) {
-                               CACHE_PTR(Z_CACHE_SLOT_P(function_name), fbc);
-                       } else {
-                               CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), ce, fbc);
-                       }
-               }
-               if (IS_CONST != IS_CONST) {
-
-               }
-       } else {
-               if (UNEXPECTED(ce->constructor == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot call constructor");
-               }
-               if (Z_OBJ(EX(This)) && Z_OBJ(EX(This))->ce != ce->constructor->common.scope && (ce->constructor->common.fn_flags & ZEND_ACC_PRIVATE)) {
-                       zend_error_noreturn(E_ERROR, "Cannot call private %s::__construct()", ce->name->val);
-               }
-               fbc = ce->constructor;
-       }
-
-       object = NULL;
-       if (!(fbc->common.fn_flags & ZEND_ACC_STATIC)) {
-               if (Z_OBJ(EX(This))) {
-                       object = Z_OBJ(EX(This));
-                       GC_REFCOUNT(object)++;
-               }
-               if (!object ||
-                   !instanceof_function(object->ce, ce TSRMLS_CC)) {
-                   /* We are calling method of the other (incompatible) class,
-                      but passing $this. This is done for compatibility with php-4. */
-                       if (fbc->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
-                               zend_error(
-                                       object ? E_DEPRECATED : E_STRICT,
-                                       "Non-static method %s::%s() should not be called statically%s",
-                                       fbc->common.scope->name->val, fbc->common.function_name->val,
-                                       object ? ", assuming $this from incompatible context" : "");
-                       } else {
-                               /* An internal function assumes $this is present and won't check that. So PHP would crash by allowing the call. */
-                               zend_error_noreturn(
-                                       E_ERROR,
-                                       "Non-static method %s::%s() cannot be called statically%s",
-                                       fbc->common.scope->name->val, fbc->common.function_name->val,
-                                       object ? ", assuming $this from incompatible context" : "");
-                       }
-               }
-       }
-
-       if (IS_VAR != IS_CONST) {
-               /* previous opcode is ZEND_FETCH_CLASS */
-               if ((opline-1)->extended_value == ZEND_FETCH_CLASS_PARENT || (opline-1)->extended_value == ZEND_FETCH_CLASS_SELF) {
-                       ce = EX(called_scope);
-               }
-       }
-
-       EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
-               fbc, opline->extended_value, ce, object, EX(call) TSRMLS_CC);
-
-       if (IS_CONST == IS_UNUSED) {
-               EX(call)->return_value = NULL;
-       }
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_CASE_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *result = EX_VAR(opline->result.var);
-
-       SAVE_OPLINE();
-       fast_equal_function(result,
-                _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
-                opline->op2.zv TSRMLS_CC);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_CONSTANT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       SAVE_OPLINE();
-       if (IS_VAR == IS_UNUSED) {
-               zend_constant *c;
-               zval *retval;
-
-               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                       c = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-               } else if ((c = zend_quick_get_constant(opline->op2.zv + 1, opline->extended_value TSRMLS_CC)) == NULL) {
-                       if ((opline->extended_value & IS_CONSTANT_UNQUALIFIED) != 0) {
-                               char *actual = (char *)zend_memrchr(Z_STRVAL_P(opline->op2.zv), '\\', Z_STRLEN_P(opline->op2.zv));
-                               if (!actual) {
-                                       ZVAL_STR(EX_VAR(opline->result.var), zend_string_copy(Z_STR_P(opline->op2.zv)));
-                               } else {
-                                       actual++;
-                                       ZVAL_STRINGL(EX_VAR(opline->result.var),
-                                                       actual, Z_STRLEN_P(opline->op2.zv) - (actual - Z_STRVAL_P(opline->op2.zv)));
-                               }
-                               /* non-qualified constant - allow text substitution */
-                               zend_error(E_NOTICE, "Use of undefined constant %s - assumed '%s'",
-                                               Z_STRVAL_P(EX_VAR(opline->result.var)), Z_STRVAL_P(EX_VAR(opline->result.var)));
-                               CHECK_EXCEPTION();
-                               ZEND_VM_NEXT_OPCODE();
-                       } else {
-                               zend_error_noreturn(E_ERROR, "Undefined constant '%s'", Z_STRVAL_P(opline->op2.zv));
-                       }
-               } else {
-                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), c);
-               }
-               retval = EX_VAR(opline->result.var);
-               ZVAL_COPY_VALUE(retval, &c->value);
-               if (Z_OPT_COPYABLE_P(retval) || Z_OPT_REFCOUNTED_P(retval)) {
-                       if (Z_OPT_COPYABLE_P(retval)) {
-                               zval_copy_ctor_func(retval);
-                       } else {
-                               Z_ADDREF_P(retval);
-                       }
-               }
-       } else {
-               /* class constant */
-               zend_class_entry *ce;
-               zval *value;
-
-               if (IS_VAR == IS_CONST) {
-                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                               value = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                               ZVAL_DEREF(value);
-                               ZVAL_DUP(EX_VAR(opline->result.var), value);
-                               goto constant_fetch_end;
-                       } else if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv))) {
-                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv));
-                       } else {
-                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op1.zv), opline->op1.zv + 1, 0 TSRMLS_CC);
-                               if (UNEXPECTED(EG(exception) != NULL)) {
-                                       HANDLE_EXCEPTION();
-                               }
-                               if (UNEXPECTED(ce == NULL)) {
-                                       zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
-                               }
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op1.zv), ce);
-                       }
-               } else {
-                       ce = Z_CE_P(EX_VAR(opline->op1.var));
-                       if ((value = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce)) != NULL) {
-                               ZVAL_DEREF(value);
-                               ZVAL_DUP(EX_VAR(opline->result.var), value);
-                               goto constant_fetch_end;
-                       }
-               }
-
-               if (EXPECTED((value = zend_hash_find(&ce->constants_table, Z_STR_P(opline->op2.zv))) != NULL)) {
-                       ZVAL_DEREF(value);
-                       if (Z_CONSTANT_P(value)) {
-                               EG(scope) = ce;
-                               zval_update_constant(value, 1 TSRMLS_CC);
-                               EG(scope) = EX(func)->op_array.scope;
-                       }
-                       if (IS_VAR == IS_CONST) {
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), value);
-                       } else {
-                               CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce, value);
-                       }
-                       ZVAL_DUP(EX_VAR(opline->result.var), value);
-               } else if (Z_STRLEN_P(opline->op2.zv) == sizeof("class")-1 && memcmp(Z_STRVAL_P(opline->op2.zv), "class", sizeof("class") - 1) == 0) {
-                       /* "class" is assigned as a case-sensitive keyword from zend_do_resolve_class_name */
-                       ZVAL_STR_COPY(EX_VAR(opline->result.var), ce->name);
-               } else {
-                       zend_error_noreturn(E_ERROR, "Undefined class constant '%s'", Z_STRVAL_P(opline->op2.zv));
-               }
-       }
-constant_fetch_end:
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *expr_ptr, new_expr;
-
-       SAVE_OPLINE();
-       if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) &&
-           (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
-               expr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-               if (IS_VAR == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
-               }
-               ZVAL_MAKE_REF(expr_ptr);
-               Z_ADDREF_P(expr_ptr);
-               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       } else {
-               expr_ptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-               if (IS_VAR == IS_TMP_VAR) {
-                       ZVAL_COPY_VALUE(&new_expr, expr_ptr);
-                       expr_ptr = &new_expr;
-               } else if (IS_VAR == IS_CONST) {
-                       if (!Z_IMMUTABLE_P(expr_ptr)) {
-                               ZVAL_DUP(&new_expr, expr_ptr);
-                               expr_ptr = &new_expr;
-                       }
-               } else if ((IS_VAR == IS_CV || IS_VAR == IS_VAR) && Z_ISREF_P(expr_ptr)) {
-                       expr_ptr = Z_REFVAL_P(expr_ptr);
-                       if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
-                       zval_ptr_dtor_nogc(free_op1);
-               } else if (IS_VAR == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
-                       Z_ADDREF_P(expr_ptr);
-               }
-       }
-
-       if (IS_CONST != IS_UNUSED) {
-
-               zval *offset = opline->op2.zv;
-               zend_string *str;
-               zend_ulong hval;
-
-add_again:
-               switch (Z_TYPE_P(offset)) {
-                       case IS_DOUBLE:
-                               hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                               goto num_index;
-                       case IS_LONG:
-                               hval = Z_LVAL_P(offset);
-num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
-                               break;
-                       case IS_STRING:
-                               str = Z_STR_P(offset);
-                               if (IS_CONST != IS_CONST) {
-                                       if (ZEND_HANDLE_NUMERIC(str, hval)) {
-                                               goto num_index;
-                                       }
-                               }
-str_index:
-                               zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
-                               break;
-                       case IS_NULL:
-                               str = STR_EMPTY_ALLOC();
-                               goto str_index;
-                       case IS_FALSE:
-                               hval = 0;
-                               goto num_index;
-                       case IS_TRUE:
-                               hval = 1;
-                               goto num_index;
-                       case IS_REFERENCE:
-                               offset = Z_REFVAL_P(offset);
-                               goto add_again;
-                               break;
-                       default:
-                               zend_error(E_WARNING, "Illegal offset type");
-                               zval_ptr_dtor(expr_ptr);
-                               /* do nothing */
-                               break;
-               }
-
-       } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
-       }
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       zval *array;
-       uint32_t size;
-       USE_OPLINE
-
-       array = EX_VAR(opline->result.var);
-       if (IS_VAR != IS_UNUSED) {
-               size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
-       } else {
-               size = 0;
-       }
-       ZVAL_NEW_ARR(array);
-       zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
-
-       if (IS_VAR != IS_UNUSED) {
-               /* Explicitly initialize array as not-packed if flag is set */
-               if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
-                       zend_hash_real_init(Z_ARRVAL_P(array), 0);
-               }
-       }
-
-       if (IS_VAR == IS_UNUSED) {
-               ZEND_VM_NEXT_OPCODE();
-#if 0 || IS_VAR != IS_UNUSED
-       } else {
-               return ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-#endif
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval tmp, *varname;
-       HashTable *target_symbol_table;
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-       if (IS_VAR == IS_CV &&
-           IS_CONST == IS_UNUSED &&
-           (opline->extended_value & ZEND_QUICK_SET)) {
-               zval *var = EX_VAR(opline->op1.var);
-
-               if (Z_REFCOUNTED_P(var)) {
-                       zend_refcounted *garbage = Z_COUNTED_P(var);
-
-                       if (!--GC_REFCOUNT(garbage)) {
-                               ZVAL_UNDEF(var);
-                               _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
-                       } else {
-                               GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
-                               ZVAL_UNDEF(var);
-                       }
-               } else {
-                       ZVAL_UNDEF(var);
-               }
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
-
-       varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       ZVAL_UNDEF(&tmp);
-       if (IS_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-               ZVAL_STR(&tmp, zval_get_string(varname));
-               varname = &tmp;
-       }
-
-       if (IS_CONST != IS_UNUSED) {
-               zend_class_entry *ce;
-
-               if (IS_CONST == IS_CONST) {
-                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+       if (EXPECTED(Z_TYPE_P(array) == IS_ARRAY)) {
+               fe_ht = Z_ARRVAL_P(array);
+               ptr = (HashPointer*)EX_VAR((opline+1)->op1.var);
+               pos = ptr->pos;
+               if (UNEXPECTED(pos == INVALID_IDX)) {
+                       /* reached end of iteration */
+                       ZEND_VM_JMP(opline->op2.jmp_addr);
+               } else if (UNEXPECTED(ptr->ht != fe_ht)) {
+                       ptr->ht = fe_ht;
+                       pos = 0;
+               } else if (UNEXPECTED(fe_ht->nInternalPointer != ptr->pos)) {
+                       if (fe_ht->u.flags & HASH_FLAG_PACKED) {
+                               pos = ptr->h;
                        } else {
-                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                               if (UNEXPECTED(EG(exception) != NULL)) {
-                                       if (IS_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-                                               zend_string_release(Z_STR(tmp));
+                               pos = fe_ht->arHash[ptr->h & fe_ht->nTableMask];
+                               while (1) {
+                                       if (pos == INVALID_IDX) {
+                                               pos = fe_ht->nInternalPointer;
+                                               break;
+                                       } else if (fe_ht->arData[pos].h == ptr->h && fe_ht->arData[pos].key == ptr->key) {
+                                               break;
                                        }
-                                       zval_ptr_dtor_nogc(free_op1);
-                                       HANDLE_EXCEPTION();
-                               }
-                               if (UNEXPECTED(ce == NULL)) {
-                                       zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
+                                       pos = Z_NEXT(fe_ht->arData[pos].val);
                                }
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
                        }
-               } else {
-                       ce = Z_CE_P(EX_VAR(opline->op2.var));
                }
-               zend_std_unset_static_property(ce, Z_STR_P(varname), ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
-       } else {
-               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-               zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
-       }
-
-       if (IS_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-               zend_string_release(Z_STR(tmp));
-       }
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *container;
-       zval *offset;
-       zend_ulong hval;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
-       }
-       if (IS_VAR != IS_UNUSED) {
-               ZVAL_DEREF(container);
-       }
-       SEPARATE_ZVAL_NOREF(container);
-       offset = opline->op2.zv;
-
-       if (IS_VAR != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
-               HashTable *ht = Z_ARRVAL_P(container);
-offset_again:
-               switch (Z_TYPE_P(offset)) {
-                       case IS_DOUBLE:
-                               hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                               zend_hash_index_del(ht, hval);
-                               break;
-                       case IS_LONG:
-                               hval = Z_LVAL_P(offset);
-num_index_dim:
-                               zend_hash_index_del(ht, hval);
-                               break;
-                       case IS_STRING:
-                               if (IS_CONST != IS_CONST) {
-                                       if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
-                                               goto num_index_dim;
-                                       }
+               while (1) {
+                       if (UNEXPECTED(pos >= fe_ht->nNumUsed)) {
+                               /* reached end of iteration */
+                               ZEND_VM_JMP(opline->op2.jmp_addr);
+                       }
+                       p = fe_ht->arData + pos;
+                       value = &p->val;
+                       if (UNEXPECTED(Z_TYPE_P(value) == IS_UNDEF)) {
+                               pos++;
+                               continue;
+                       } else if (UNEXPECTED(Z_TYPE_P(value) == IS_INDIRECT)) {
+                               value = Z_INDIRECT_P(value);
+                               if (UNEXPECTED(Z_TYPE_P(value) == IS_UNDEF)) {
+                                       pos++;
+                                       continue;
                                }
-                               if (ht == &EG(symbol_table).ht) {
-                                       zend_delete_global_variable(Z_STR_P(offset) TSRMLS_CC);
+                       }
+                       if (opline->extended_value & ZEND_FE_FETCH_BYREF) {
+                               ZVAL_MAKE_REF(value);
+                               Z_ADDREF_P(value);
+                               ZVAL_REF(EX_VAR(opline->result.var), Z_REF_P(value));
+                       } else {
+                               ZVAL_COPY(EX_VAR(opline->result.var), value);
+                       }
+                       if (opline->extended_value & ZEND_FE_FETCH_WITH_KEY) {
+                               if (!p->key) {
+                                       ZVAL_LONG(EX_VAR((opline+1)->result.var), p->h);
                                } else {
-                                       zend_hash_del(ht, Z_STR_P(offset));
+                                       ZVAL_STR_COPY(EX_VAR((opline+1)->result.var), p->key);
                                }
-                               break;
-                       case IS_NULL:
-                               zend_hash_del(ht, STR_EMPTY_ALLOC());
-                               break;
-                       case IS_FALSE:
-                               hval = 0;
-                               goto num_index_dim;
-                       case IS_TRUE:
-                               hval = 1;
-                               goto num_index_dim;
-                       case IS_RESOURCE:
-                               hval = Z_RES_HANDLE_P(offset);
-                               goto num_index_dim;
-                       case IS_REFERENCE:
-                               offset = Z_REFVAL_P(offset);
-                               goto offset_again;
-                               break;
-                       default:
-                               zend_error(E_WARNING, "Illegal offset type in unset");
-                               break;
-               }
-
-       } else if (IS_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use object as array");
-               }
-//???          if (IS_CONST == IS_CONST) {
-//???                  zval_copy_ctor(offset);
-//???          }
-               Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
-
-       } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
-               ZEND_VM_CONTINUE(); /* bailed out before */
-       } else {
-
-       }
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *container;
-       zval *offset;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
-       }
-       offset = opline->op2.zv;
-
-       if (IS_VAR != IS_UNUSED) {
-               ZVAL_DEREF(container);
-       }
-       if (IS_VAR == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
-               if (Z_OBJ_HT_P(container)->unset_property) {
-                       Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
-               } else {
-                       zend_error(E_NOTICE, "Trying to unset property of non-object");
-               }
-       }
-
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *value;
-
-       SAVE_OPLINE();
-       if (IS_VAR == IS_CV &&
-           IS_CONST == IS_UNUSED &&
-           (opline->extended_value & ZEND_QUICK_SET)) {
-               value = EX_VAR(opline->op1.var);
-               if (opline->extended_value & ZEND_ISSET) {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               !i_zend_is_true(value TSRMLS_CC));
-                       CHECK_EXCEPTION();
+                       }
+                       break;
                }
+               do {
+                       pos++;
+                       if (pos >= fe_ht->nNumUsed) {
+                               fe_ht->nInternalPointer = ptr->pos = INVALID_IDX;
+                               ZEND_VM_INC_OPCODE();
+                               ZEND_VM_NEXT_OPCODE();
+                       }
+                       p = fe_ht->arData + pos;
+               } while (Z_TYPE(p->val) == IS_UNDEF ||
+                            (Z_TYPE(p->val) == IS_INDIRECT &&
+                             Z_TYPE_P(Z_INDIRECT(p->val)) == IS_UNDEF));
+               fe_ht->nInternalPointer = ptr->pos = pos;
+               ptr->h = fe_ht->arData[pos].h;
+               ptr->key = fe_ht->arData[pos].key;
+               ZEND_VM_INC_OPCODE();
                ZEND_VM_NEXT_OPCODE();
-       } else {
-               zend_free_op free_op1;
-               zval tmp, *varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-               ZVAL_UNDEF(&tmp);
-               if (IS_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-                       ZVAL_STR(&tmp, zval_get_string(varname));
-                       varname = &tmp;
-               }
+       } else if (EXPECTED(Z_TYPE_P(array) == IS_OBJECT)) {
+               zend_object_iterator *iter;
 
-               if (IS_CONST != IS_UNUSED) {
-                       zend_class_entry *ce;
+               if ((iter = zend_iterator_unwrap(array TSRMLS_CC)) == NULL) {
+                       /* plain object */
+                       zend_object *zobj = Z_OBJ_P(array);
 
-                       if (IS_CONST == IS_CONST) {
-                               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                                       ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+                       fe_ht = Z_OBJPROP_P(array);
+                       ptr = (HashPointer*)EX_VAR((opline+1)->op1.var);
+                       pos = ptr->pos;
+                       if (pos == INVALID_IDX) {
+                               /* reached end of iteration */
+                               ZEND_VM_JMP(opline->op2.jmp_addr);
+                       } else if (UNEXPECTED(ptr->ht != fe_ht)) {
+                               ptr->ht = fe_ht;
+                               pos = 0;
+                       } else if (UNEXPECTED(fe_ht->nInternalPointer != ptr->pos)) {
+                               if (fe_ht->u.flags & HASH_FLAG_PACKED) {
+                                       pos = ptr->h;
                                } else {
-                                       ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                                       if (UNEXPECTED(ce == NULL)) {
-                                               CHECK_EXCEPTION();
-                                               ZEND_VM_NEXT_OPCODE();
+                                       pos = fe_ht->arHash[ptr->h & fe_ht->nTableMask];
+                                       while (1) {
+                                               if (pos == INVALID_IDX) {
+                                                       pos = fe_ht->nInternalPointer;
+                                                       break;
+                                               } else if (fe_ht->arData[pos].h == ptr->h && fe_ht->arData[pos].key == ptr->key) {
+                                                       break;
+                                               }
+                                               pos = Z_NEXT(fe_ht->arData[pos].val);
                                        }
-                                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
                                }
-                       } else {
-                               ce = Z_CE_P(EX_VAR(opline->op2.var));
                        }
-                       value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
-               } else {
-                       HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-                       value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
-               }
-
-               if (IS_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-                       zend_string_release(Z_STR(tmp));
-               }
-               zval_ptr_dtor_nogc(free_op1);
-
-               if (opline->extended_value & ZEND_ISSET) {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               value && Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               !value || !i_zend_is_true(value TSRMLS_CC));
-               }
-
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *container;
-       int result;
-       zend_ulong hval;
-       zval *offset;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-       offset = opline->op2.zv;
+                       while (1) {
+                               if (UNEXPECTED(pos >= fe_ht->nNumUsed)) {
+                                       /* reached end of iteration */
+                                       ZEND_VM_JMP(opline->op2.jmp_addr);
+                               }
 
-       if (IS_VAR != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
-               HashTable *ht = Z_ARRVAL_P(container);
-               zval *value;
-               zend_string *str;
+                               p = fe_ht->arData + pos;
+                               value = &p->val;
+                               if (UNEXPECTED(Z_TYPE_P(value) == IS_UNDEF)) {
+                                       pos++;
+                                       continue;
+                               } else if (UNEXPECTED(Z_TYPE_P(value) == IS_INDIRECT)) {
+                                       value = Z_INDIRECT_P(value);
+                                       if (UNEXPECTED(Z_TYPE_P(value) == IS_UNDEF)) {
+                                               pos++;
+                                               continue;
+                                       }
+                               }
 
-isset_again:
-               if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
-                       str = Z_STR_P(offset);
-                       if (IS_CONST != IS_CONST) {
-                               if (ZEND_HANDLE_NUMERIC(str, hval)) {
-                                       goto num_index_prop;
+                               if (UNEXPECTED(!p->key)) {
+                                       if (opline->extended_value & ZEND_FE_FETCH_WITH_KEY) {
+                                               ZVAL_LONG(EX_VAR((opline+1)->result.var), p->h);
+                                       }
+                                       break;
+                               } else if (zend_check_property_access(zobj, p->key TSRMLS_CC) == SUCCESS) {
+                                       if (opline->extended_value & ZEND_FE_FETCH_WITH_KEY) {
+                                               if (p->key->val[0]) {
+                                                       ZVAL_STR_COPY(EX_VAR((opline+1)->result.var), p->key);
+                                               } else {
+                                                       const char *class_name, *prop_name;
+                                                       size_t prop_name_len;
+                                                       zend_unmangle_property_name_ex(
+                                                               p->key, &class_name, &prop_name, &prop_name_len);
+                                                       ZVAL_STRINGL(EX_VAR((opline+1)->result.var), prop_name, prop_name_len);
+                                               }
+                                       }
+                                       break;
                                }
+                               pos++;
                        }
-str_index_prop:
-                       value = zend_hash_find_ind(ht, str);
-               } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
-                       hval = Z_LVAL_P(offset);
-num_index_prop:
-                       value = zend_hash_index_find(ht, hval);
-               } else {
-                       switch (Z_TYPE_P(offset)) {
-                               case IS_DOUBLE:
-                                       hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                                       goto num_index_prop;
-                               case IS_NULL:
-                                       str = STR_EMPTY_ALLOC();
-                                       goto str_index_prop;
-                               case IS_FALSE:
-                                       hval = 0;
-                                       goto num_index_prop;
-                               case IS_TRUE:
-                                       hval = 1;
-                                       goto num_index_prop;
-                               case IS_RESOURCE:
-                                       hval = Z_RES_HANDLE_P(offset);
-                                       goto num_index_prop;
-                               case IS_REFERENCE:
-                                       offset = Z_REFVAL_P(offset);
-                                       goto isset_again;
-                               default:
-                                       zend_error(E_WARNING, "Illegal offset type in isset or empty");
-                                       value = NULL;
-                                       break;
+                       if (opline->extended_value & ZEND_FE_FETCH_BYREF) {
+                               ZVAL_MAKE_REF(value);
+                               Z_ADDREF_P(value);
+                               ZVAL_REF(EX_VAR(opline->result.var), Z_REF_P(value));
+                       } else {
+                               ZVAL_COPY(EX_VAR(opline->result.var), value);
                        }
-               }
-
-               if (opline->extended_value & ZEND_ISSET) {
-                       /* > IS_NULL means not IS_UNDEF and not IS_NULL */
-                       result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
-               }
-       } else if (IS_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
-                       result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
+                       do {
+                               pos++;
+                               if (pos >= fe_ht->nNumUsed) {
+                                       fe_ht->nInternalPointer = ptr->pos = INVALID_IDX;
+                                       ZEND_VM_INC_OPCODE();
+                                       ZEND_VM_NEXT_OPCODE();
+                               }
+                               p = fe_ht->arData + pos;
+                       } while (Z_TYPE(p->val) == IS_UNDEF ||
+                                    (Z_TYPE(p->val) == IS_INDIRECT &&
+                                     Z_TYPE_P(Z_INDIRECT(p->val)) == IS_UNDEF) ||
+                                    (EXPECTED(p->key != NULL) &&
+                                     zend_check_property_access(zobj, p->key TSRMLS_CC) == FAILURE));
+                       fe_ht->nInternalPointer = ptr->pos = pos;
+                       ptr->h = fe_ht->arData[pos].h;
+                       ptr->key = fe_ht->arData[pos].key;
+                       ZEND_VM_INC_OPCODE();
+                       ZEND_VM_NEXT_OPCODE();
                } else {
-                       zend_error(E_NOTICE, "Trying to check element of non-array");
-                       result = 0;
-               }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
-               }
-       } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
-               zval tmp;
-
-               result = 0;
-               if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
-                       if (IS_CONST == IS_CV || IS_CONST == IS_VAR) {
-                               ZVAL_DEREF(offset);
+                       /* !iter happens from exception */
+                       if (iter && ++iter->index > 0) {
+                               /* This could cause an endless loop if index becomes zero again.
+                                * In case that ever happens we need an additional flag. */
+                               iter->funcs->move_forward(iter TSRMLS_CC);
+                               if (UNEXPECTED(EG(exception) != NULL)) {
+                                       zval_ptr_dtor(array_ref);
+                                       HANDLE_EXCEPTION();
+                               }
                        }
-                       if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
-                                       || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
-                                               && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
-                               ZVAL_DUP(&tmp, offset);
-                               convert_to_long(&tmp);
-                               offset = &tmp;
+                       /* If index is zero we come from FE_RESET and checked valid() already. */
+                       if (!iter || (iter->index > 0 && iter->funcs->valid(iter TSRMLS_CC) == FAILURE)) {
+                               /* reached end of iteration */
+                               if (UNEXPECTED(EG(exception) != NULL)) {
+                                       zval_ptr_dtor(array_ref);
+                                       HANDLE_EXCEPTION();
+                               }
+                               ZEND_VM_JMP(opline->op2.jmp_addr);
                        }
-               }
-               if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
-                       if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
-                               if ((opline->extended_value & ZEND_ISSET) ||
-                                   Z_STRVAL_P(container)[offset->value.lval] != '0') {
-                                       result = 1;
+                       value = iter->funcs->get_current_data(iter TSRMLS_CC);
+                       if (UNEXPECTED(EG(exception) != NULL)) {
+                               zval_ptr_dtor(array_ref);
+                               HANDLE_EXCEPTION();
+                       }
+                       if (!value) {
+                               /* failure in get_current_data */
+                               ZEND_VM_JMP(opline->op2.jmp_addr);
+                       }
+                       if (opline->extended_value & ZEND_FE_FETCH_BYREF) {
+                               ZVAL_MAKE_REF(value);
+                               Z_ADDREF_P(value);
+                               ZVAL_REF(EX_VAR(opline->result.var), Z_REF_P(value));
+                       } else {
+                               ZVAL_COPY(EX_VAR(opline->result.var), value);
+                       }
+                       if (opline->extended_value & ZEND_FE_FETCH_WITH_KEY) {
+                               if (iter->funcs->get_current_key) {
+                                       iter->funcs->get_current_key(iter, EX_VAR((opline+1)->result.var) TSRMLS_CC);
+                                       if (UNEXPECTED(EG(exception) != NULL)) {
+                                               zval_ptr_dtor(array_ref);
+                                               HANDLE_EXCEPTION();
+                                       }
+                               } else {
+                                       ZVAL_LONG(EX_VAR((opline+1)->result.var), iter->index);
                                }
                        }
-               }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
+                       ZEND_VM_INC_OPCODE();
+                       ZEND_VM_NEXT_OPCODE();
                }
        } else {
-               result = ((opline->extended_value & ZEND_ISSET) == 0);
+               zend_error(E_WARNING, "Invalid argument supplied for foreach()");
+               ZEND_VM_JMP(opline->op2.jmp_addr);
        }
-
-       ZVAL_BOOL(EX_VAR(opline->result.var), result);
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_EXIT_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
+#if 0 || (IS_VAR != IS_UNUSED)
        USE_OPLINE
-       zend_free_op free_op1;
-       zval *container;
-       int result;
-       zval *offset;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-       offset = opline->op2.zv;
+       if (IS_VAR != IS_UNUSED) {
+               zend_free_op free_op1;
+               zval *ptr = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
 
-       if (IS_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
-                       result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+               if (Z_TYPE_P(ptr) == IS_LONG) {
+                       EG(exit_status) = Z_LVAL_P(ptr);
                } else {
-                       zend_error(E_NOTICE, "Trying to check property of non-object");
-                       result = 0;
-               }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
+                       zend_print_variable(ptr TSRMLS_CC);
                }
-       } else {
-               result = ((opline->extended_value & ZEND_ISSET) == 0);
+               zval_ptr_dtor_nogc(free_op1);
        }
-
-       ZVAL_BOOL(EX_VAR(opline->result.var), result);
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+#endif
+       zend_bailout();
+       ZEND_VM_NEXT_OPCODE(); /* Never reached */
 }
 
-static int ZEND_FASTCALL  ZEND_INSTANCEOF_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_JMP_SET_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
-       zval *expr;
-       zend_bool result;
+       zval *value;
+       int is_ref = 0;
 
        SAVE_OPLINE();
-       expr = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
-       if (Z_TYPE_P(expr) == IS_OBJECT) {
-               zend_class_entry *ce;
+       value = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
 
-               if (IS_CONST == IS_CONST) {
-                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                       } else {
-                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, ZEND_FETCH_CLASS_NO_AUTOLOAD TSRMLS_CC);
-                               if (UNEXPECTED(ce == NULL)) {
-                                       ZVAL_FALSE(EX_VAR(opline->result.var));
-                                       zval_ptr_dtor_nogc(free_op1);
-                                       CHECK_EXCEPTION();
-                                       ZEND_VM_NEXT_OPCODE();
-                               }
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+       if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && Z_ISREF_P(value)) {
+               is_ref = 1;
+               value = Z_REFVAL_P(value);
+       }
+       if (i_zend_is_true(value TSRMLS_CC)) {
+               ZVAL_COPY_VALUE(EX_VAR(opline->result.var), value);
+               if (IS_VAR == IS_CONST) {
+                       if (UNEXPECTED(Z_OPT_COPYABLE_P(value))) {
+                               zval_copy_ctor_func(EX_VAR(opline->result.var));
                        }
-               } else {
-                       ce = Z_CE_P(EX_VAR(opline->op2.var));
+               } else if (IS_VAR == IS_CV) {
+                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+               } else if (IS_VAR == IS_VAR && is_ref) {
+                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+                       zval_ptr_dtor_nogc(free_op1);
                }
-               result = instanceof_function(Z_OBJCE_P(expr), ce TSRMLS_CC);
-       } else {
-               result = 0;
+               ZEND_VM_JMP(opline->op2.jmp_addr);
        }
-       ZVAL_BOOL(EX_VAR(opline->result.var), result);
+
        zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_YIELD_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_COALESCE_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zend_free_op free_op1;
+       zval *value;
+       int is_ref = 0;
 
-       /* The generator object is stored in EX(return_value) */
-       zend_generator *generator = (zend_generator *) EX(return_value);
+       SAVE_OPLINE();
+       value = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
 
-       if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
-               zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
+       if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && Z_ISREF_P(value)) {
+               is_ref = 1;
+               value = Z_REFVAL_P(value);
        }
 
-       /* Destroy the previously yielded value */
-       zval_ptr_dtor(&generator->value);
-
-       /* Destroy the previously yielded key */
-       zval_ptr_dtor(&generator->key);
-
-       /* Set the new yielded value */
-       if (IS_VAR != IS_UNUSED) {
-               zend_free_op free_op1;
-
-               if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
-                       /* Constants and temporary variables aren't yieldable by reference,
-                        * but we still allow them with a notice. */
-                       if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
-                               zval *value;
-
-                               zend_error(E_NOTICE, "Only variable references should be yielded by reference");
-
-                               value = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-                               ZVAL_COPY_VALUE(&generator->value, value);
-                               if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
-
-                               /* Temporary variables don't need ctor copying */
-                               if (IS_VAR != IS_TMP_VAR) {
-                                       zval_opt_copy_ctor(&generator->value);
-                               }
-                       } else {
-                               zval *value_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-                               if (IS_VAR == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
-                                       zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
-                               }
-
-                               /* If a function call result is yielded and the function did
-                                * not return by reference we throw a notice. */
-                               if (IS_VAR == IS_VAR &&
-                                   (value_ptr == &EG(uninitialized_zval) ||
-                                    (opline->extended_value == ZEND_RETURNS_FUNCTION &&
-                                     !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
-                                       zend_error(E_NOTICE, "Only variable references should be yielded by reference");
-                               } else {
-                                       ZVAL_MAKE_REF(value_ptr);
-                               }
-                               ZVAL_COPY(&generator->value, value_ptr);
-
-                               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-                       }
-               } else {
-                       zval *value = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-                       /* Consts, temporary variables and references need copying */
-                       if (IS_VAR == IS_CONST) {
-                               ZVAL_DUP(&generator->value, value);
-                       } else if (IS_VAR == IS_TMP_VAR) {
-                               ZVAL_COPY_VALUE(&generator->value, value);
-            } else if ((IS_VAR == IS_CV || IS_VAR == IS_VAR) && Z_ISREF_P(value)) {
-                               ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
-                               zval_ptr_dtor_nogc(free_op1);
-                       } else {
-                               ZVAL_COPY_VALUE(&generator->value, value);
-                               if (IS_VAR == IS_CV) {
-                                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
-                               }
+       if (Z_TYPE_P(value) > IS_NULL) {
+               ZVAL_COPY_VALUE(EX_VAR(opline->result.var), value);
+               if (IS_VAR == IS_CONST) {
+                       if (UNEXPECTED(Z_OPT_COPYABLE_P(value))) {
+                               zval_copy_ctor_func(EX_VAR(opline->result.var));
                        }
+               } else if (IS_VAR == IS_CV) {
+                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+               } else if (IS_VAR == IS_VAR && is_ref) {
+                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+                       zval_ptr_dtor_nogc(free_op1);
                }
-       } else {
-               /* If no value was specified yield null */
-               ZVAL_NULL(&generator->value);
+               ZEND_VM_JMP(opline->op2.jmp_addr);
        }
 
-       /* Set the new yielded key */
-       if (IS_CONST != IS_UNUSED) {
+       zval_ptr_dtor_nogc(free_op1);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-               zval *key = opline->op2.zv;
+static int ZEND_FASTCALL  ZEND_QM_ASSIGN_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *value;
 
-               /* Consts, temporary variables and references need copying */
-               if (IS_CONST == IS_CONST) {
-                       ZVAL_DUP(&generator->key, key);
-               } else if (IS_CONST == IS_TMP_VAR) {
-                       ZVAL_COPY_VALUE(&generator->key, key);
-               } else if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) && Z_ISREF_P(key)) {
-                       ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
+       SAVE_OPLINE();
+       value = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
 
-               } else {
-                       ZVAL_COPY_VALUE(&generator->key, key);
-                       if (IS_CONST == IS_CV) {
-                               if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
+       if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && Z_ISREF_P(value)) {
+               ZVAL_COPY(EX_VAR(opline->result.var), Z_REFVAL_P(value));
+               zval_ptr_dtor_nogc(free_op1);
+       } else {
+               ZVAL_COPY_VALUE(EX_VAR(opline->result.var), value);
+               if (IS_VAR == IS_CONST) {
+                       if (UNEXPECTED(Z_OPT_COPYABLE_P(value))) {
+                               zval_copy_ctor_func(EX_VAR(opline->result.var));
                        }
+               } else if (IS_VAR == IS_CV) {
+                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
                }
-
-               if (Z_TYPE(generator->key) == IS_LONG
-                   && Z_LVAL(generator->key) > generator->largest_used_integer_key
-               ) {
-                       generator->largest_used_integer_key = Z_LVAL(generator->key);
-               }
-       } else {
-               /* If no key was specified we use auto-increment keys */
-               generator->largest_used_integer_key++;
-               ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
-       }
-
-       if (RETURN_VALUE_USED(opline)) {
-               /* If the return value of yield is used set the send
-                * target and initialize it to NULL */
-               generator->send_target = EX_VAR(opline->result.var);
-               ZVAL_NULL(generator->send_target);
-       } else {
-               generator->send_target = NULL;
        }
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       /* We increment to the next op, so we are at the correct position when the
-        * generator is resumed. */
-       ZEND_VM_INC_OPCODE();
+static int ZEND_FASTCALL  ZEND_STRLEN_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zval *value;
+       zend_free_op free_op1;
 
-       /* The GOTO VM uses a local opline variable. We need to set the opline
-        * variable in execute_data so we don't resume at an old position. */
        SAVE_OPLINE();
+       value = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
+       if (EXPECTED(Z_TYPE_P(value) == IS_STRING)) {
+               ZVAL_LONG(EX_VAR(opline->result.var), Z_STRLEN_P(value));
+       } else {
+               if (Z_TYPE_P(value) < IS_TRUE) {
+                       ZVAL_LONG(EX_VAR(opline->result.var), 0);
+               } else if (Z_TYPE_P(value) == IS_TRUE) {
+                       ZVAL_LONG(EX_VAR(opline->result.var), 1);
+               } else if (Z_TYPE_P(value) <= IS_DOUBLE) {
+                       zend_string *str = zval_get_string(value);
+                       ZVAL_LONG(EX_VAR(opline->result.var), str->len);
+                       zend_string_release(str);
+               } else if (Z_TYPE_P(value) == IS_OBJECT) {
+                       zend_string *str;
+                       zval tmp;
 
-       ZEND_VM_RETURN();
+                       ZVAL_COPY(&tmp, value);
+                       if (parse_arg_object_to_str(&tmp, &str, IS_STRING TSRMLS_CC) == FAILURE) {
+                               goto strlen_error;
+                       }
+                       ZVAL_LONG(EX_VAR(opline->result.var), str->len);
+                       zval_dtor(&tmp);
+               } else {
+strlen_error:
+                       zend_error(E_WARNING, "strlen() expects parameter 1 to be string, %s given", zend_get_type_by_const(Z_TYPE_P(value)));
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
+       }
+       zval_ptr_dtor_nogc(free_op1);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_POW_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_TYPE_CHECK_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zval *value;
        zend_free_op free_op1;
 
        SAVE_OPLINE();
-       pow_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               opline->op2.zv TSRMLS_CC);
+       value = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
+       switch (opline->extended_value) {
+               case IS_NULL:
+               case IS_LONG:
+               case IS_DOUBLE:
+               case IS_STRING:
+               case IS_ARRAY:
+                       ZVAL_BOOL(EX_VAR(opline->result.var), Z_TYPE_P(value) == opline->extended_value);
+                       break;
+               case _IS_BOOL:
+                       ZVAL_BOOL(EX_VAR(opline->result.var), Z_TYPE_P(value) == IS_TRUE || Z_TYPE_P(value) == IS_FALSE);
+                       break;
+               case IS_OBJECT:
+                       if (Z_TYPE_P(value) == opline->extended_value) {
+                               zend_class_entry *ce = Z_OBJCE_P(value);
+                               if (ce->name->len == sizeof("__PHP_Incomplete_Class") - 1
+                                               && !strncmp(ce->name->val, "__PHP_Incomplete_Class", ce->name->len)) {
+                                       ZVAL_FALSE(EX_VAR(opline->result.var));
+                               } else {
+                                       ZVAL_TRUE(EX_VAR(opline->result.var));
+                               }
+                       } else {
+                               ZVAL_FALSE(EX_VAR(opline->result.var));
+                       }
+                       break;
+               case IS_RESOURCE:
+                       if (Z_TYPE_P(value) == opline->extended_value) {
+                               const char *type_name = zend_rsrc_list_get_rsrc_type(Z_RES_P(value) TSRMLS_CC);
+                               ZVAL_BOOL(EX_VAR(opline->result.var), type_name != NULL);
+                       } else {
+                               ZVAL_FALSE(EX_VAR(opline->result.var));
+                       }
+                       break;
+               EMPTY_SWITCH_DEFAULT_CASE()
+       }
        zval_ptr_dtor_nogc(free_op1);
-
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_POW_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_binary_assign_op_helper_SPEC_VAR_CONST(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_MOD_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_MOD_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
 
        SAVE_OPLINE();
        fast_mod_function(EX_VAR(opline->result.var),
                _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               opline->op2.zv TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
-       zval_ptr_dtor_nogc(free_op2);
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_SL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
 
        SAVE_OPLINE();
        shift_left_function(EX_VAR(opline->result.var),
                _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               opline->op2.zv TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
-       zval_ptr_dtor_nogc(free_op2);
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_SR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
 
        SAVE_OPLINE();
        shift_right_function(EX_VAR(opline->result.var),
                _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               opline->op2.zv TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
-       zval_ptr_dtor_nogc(free_op2);
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
 
        SAVE_OPLINE();
        concat_function(EX_VAR(opline->result.var),
                _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               opline->op2.zv TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
-       zval_ptr_dtor_nogc(free_op2);
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
 
        SAVE_OPLINE();
        fast_is_identical_function(EX_VAR(opline->result.var),
                _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               opline->op2.zv TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
-       zval_ptr_dtor_nogc(free_op2);
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
        zval *result = EX_VAR(opline->result.var);
 
        SAVE_OPLINE();
        fast_is_not_identical_function(result,
                _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               opline->op2.zv TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
-       zval_ptr_dtor_nogc(free_op2);
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
 
        SAVE_OPLINE();
        bitwise_or_function(EX_VAR(opline->result.var),
                _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               opline->op2.zv TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
-       zval_ptr_dtor_nogc(free_op2);
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
 
        SAVE_OPLINE();
        bitwise_and_function(EX_VAR(opline->result.var),
                _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               opline->op2.zv TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
-       zval_ptr_dtor_nogc(free_op2);
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
 
        SAVE_OPLINE();
        bitwise_xor_function(EX_VAR(opline->result.var),
                _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               opline->op2.zv TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
-       zval_ptr_dtor_nogc(free_op2);
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
 
        SAVE_OPLINE();
        boolean_xor_function(EX_VAR(opline->result.var),
                _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               opline->op2.zv TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
-       zval_ptr_dtor_nogc(free_op2);
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2, free_op_data1;
+       zend_free_op free_op1, free_op_data1;
        zval *object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-       zval *property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       zval *property = opline->op2.zv;
        zval *value;
        zval *zptr;
 
@@ -19547,7 +14841,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(int (*bin
 
        if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to assign property of non-object");
-               zval_ptr_dtor_nogc(free_op2);
+
                FREE_OP(free_op_data1);
 
                if (RETURN_VALUE_USED(opline)) {
@@ -19557,7 +14851,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(int (*bin
                /* here we are sure we are dealing with an object */
                if (opline->extended_value == ZEND_ASSIGN_OBJ
                        && EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-                       && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+                       && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
 
                        ZVAL_DEREF(zptr);
                        SEPARATE_ZVAL_NOREF(zptr);
@@ -19572,7 +14866,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(int (*bin
 
                        if (opline->extended_value == ZEND_ASSIGN_OBJ) {
                                if (Z_OBJ_HT_P(object)->read_property) {
-                                       z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+                                       z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
                                }
                        } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
                                if (Z_OBJ_HT_P(object)->read_dimension) {
@@ -19593,7 +14887,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(int (*bin
                                SEPARATE_ZVAL_IF_NOT_REF(z);
                                binary_op(z, z, value TSRMLS_CC);
                                if (opline->extended_value == ZEND_ASSIGN_OBJ) {
-                                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+                                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
                                } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
                                        Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
                                }
@@ -19609,7 +14903,6 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(int (*bin
                        }
                }
 
-               zval_ptr_dtor_nogc(free_op2);
                FREE_OP(free_op_data1);
        }
 
@@ -19620,10 +14913,10 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(int (*bin
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2, free_op_data1;
+       zend_free_op free_op1, free_op_data1;
        zval *var_ptr, rv;
        zval *value, *container;
 
@@ -19639,11 +14932,11 @@ static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(int (*bin
                if (IS_VAR == IS_VAR && !(free_op1 != NULL)) {
                        Z_ADDREF_P(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
                }
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else {
-               zval *dim = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+               zval *dim = opline->op2.zv;
 
-               zend_fetch_dimension_address_RW(&rv, container, dim, IS_TMP_VAR TSRMLS_CC);
+               zend_fetch_dimension_address_RW(&rv, container, dim, IS_CONST TSRMLS_CC);
                value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
                ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
                var_ptr = Z_INDIRECT(rv);
@@ -19668,7 +14961,6 @@ static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(int (*bin
                }
        }
 
-       zval_ptr_dtor_nogc(free_op2);
        FREE_OP(free_op_data1);
        if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
@@ -19676,15 +14968,15 @@ static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(int (*bin
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
        zval *var_ptr;
        zval *value;
 
        SAVE_OPLINE();
-       value = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       value = opline->op2.zv;
        var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
 
        if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
@@ -19706,159 +14998,158 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_TMP(int (*binary_
                }
        }
 
-       zval_ptr_dtor_nogc(free_op2);
        if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_ADD_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_ADD_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_VAR_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SUB_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_SUB_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_VAR_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_MUL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_MUL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_VAR_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_DIV_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_DIV_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_VAR_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_MOD_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_MOD_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_VAR_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_SL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_VAR_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_SR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_VAR_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_CONCAT_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_CONCAT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_VAR_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_OR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_OR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_VAR_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_AND_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_AND_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_VAR_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_VAR_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_TMP(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
        zval *object;
        zval *property;
        zval *retval;
@@ -19866,7 +15157,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_TMP(incdec_t i
 
        SAVE_OPLINE();
        object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-       property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       property = opline->op2.zv;
        retval = EX_VAR(opline->result.var);
 
        if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
@@ -19879,7 +15170,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_TMP(incdec_t i
 
        if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-               zval_ptr_dtor_nogc(free_op2);
+
                if (RETURN_VALUE_USED(opline)) {
                        ZVAL_NULL(retval);
                }
@@ -19891,7 +15182,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_TMP(incdec_t i
        /* here we are sure we are dealing with an object */
 
        if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
 
                ZVAL_DEREF(zptr);
                SEPARATE_ZVAL_NOREF(zptr);
@@ -19904,7 +15195,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_TMP(incdec_t i
                zval rv;
 
                if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
-                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
 
                        if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval rv;
@@ -19919,7 +15210,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_TMP(incdec_t i
                        SEPARATE_ZVAL_IF_NOT_REF(z);
                        incdec_op(z);
                        ZVAL_COPY_VALUE(retval, z);
-                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
                        SELECTIVE_PZVAL_LOCK(retval, opline);
                        zval_ptr_dtor(z);
                } else {
@@ -19930,26 +15221,25 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_TMP(incdec_t i
                }
        }
 
-       zval_ptr_dtor_nogc(free_op2);
        if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_PRE_INC_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_PRE_INC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_pre_incdec_property_helper_SPEC_VAR_TMP(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_pre_incdec_property_helper_SPEC_VAR_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_pre_incdec_property_helper_SPEC_VAR_TMP(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_pre_incdec_property_helper_SPEC_VAR_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_TMP(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
        zval *object;
        zval *property;
        zval *retval;
@@ -19957,7 +15247,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_TMP(incdec_t
 
        SAVE_OPLINE();
        object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-       property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       property = opline->op2.zv;
        retval = EX_VAR(opline->result.var);
 
        if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
@@ -19970,7 +15260,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_TMP(incdec_t
 
        if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-               zval_ptr_dtor_nogc(free_op2);
+
                ZVAL_NULL(retval);
                if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
                CHECK_EXCEPTION();
@@ -19980,7 +15270,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_TMP(incdec_t
        /* here we are sure we are dealing with an object */
 
        if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
 
                ZVAL_DEREF(zptr);
                ZVAL_COPY_VALUE(retval, zptr);
@@ -19990,7 +15280,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_TMP(incdec_t
        } else {
                if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
                        zval rv;
-                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
                        zval z_copy;
 
                        if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
@@ -20006,7 +15296,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_TMP(incdec_t
                        ZVAL_DUP(&z_copy, z);
                        incdec_op(&z_copy);
                        if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
-                       Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+                       Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
                        zval_ptr_dtor(&z_copy);
                        zval_ptr_dtor(z);
                } else {
@@ -20015,41 +15305,40 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_TMP(incdec_t
                }
        }
 
-       zval_ptr_dtor_nogc(free_op2);
        if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_POST_INC_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_POST_INC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_post_incdec_property_helper_SPEC_VAR_TMP(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_post_incdec_property_helper_SPEC_VAR_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_post_incdec_property_helper_SPEC_VAR_TMP(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_post_incdec_property_helper_SPEC_VAR_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
        zval *container;
 
        SAVE_OPLINE();
        container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-       zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
+       zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+
        zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
        zval *container;
 
        SAVE_OPLINE();
@@ -20059,8 +15348,8 @@ static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HAND
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
        ZVAL_DEREF(container);
-       zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
+       zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+
        if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
                EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
@@ -20069,10 +15358,10 @@ static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HAND
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
        zval *container;
 
        SAVE_OPLINE();
@@ -20082,8 +15371,8 @@ static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HAN
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
        ZVAL_DEREF(container);
-       zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
+       zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+
        if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
                EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
@@ -20092,26 +15381,26 @@ static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HAN
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
        zval *container;
 
        SAVE_OPLINE();
        container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-       zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
+       zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+
        zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zval *container;
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
 
        SAVE_OPLINE();
 
@@ -20124,29 +15413,29 @@ static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_VAR_TMP_HANDLER(ZEND_OPCO
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
                ZVAL_DEREF(container);
-               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
+               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
                if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
                        EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
                }
-               zval_ptr_dtor_nogc(free_op2);
+
                if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        } else {
-               if (IS_TMP_VAR == IS_UNUSED) {
+               if (IS_CONST == IS_UNUSED) {
                        zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
                }
                container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op2);
+               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+
                zval_ptr_dtor_nogc(free_op1);
        }
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_UNSET_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_UNSET_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
        zval *container;
 
        SAVE_OPLINE();
@@ -20156,8 +15445,8 @@ static int ZEND_FASTCALL  ZEND_FETCH_DIM_UNSET_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
        ZVAL_DEREF(container);
-       zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
+       zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+
        if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
                EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
@@ -20166,17 +15455,17 @@ static int ZEND_FASTCALL  ZEND_FETCH_DIM_UNSET_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
        zval *container;
-       zend_free_op free_op2;
+
        zval *offset;
 
        SAVE_OPLINE();
        container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-       offset  = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       offset  = opline->op2.zv;
 
        if ((IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
            UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
@@ -20187,7 +15476,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HAND
 
                /* here we are sure we are dealing with an object */
                do {
-                       if (IS_TMP_VAR == IS_CONST &&
+                       if (IS_CONST == IS_CONST &&
                                EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
                                zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
                                zend_object *zobj = Z_OBJ_P(container);
@@ -20207,7 +15496,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HAND
                                }
                        }
 
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
 
                        if (retval != EX_VAR(opline->result.var)) {
                                ZVAL_COPY(EX_VAR(opline->result.var), retval);
@@ -20215,29 +15504,28 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HAND
                } while (0);
        }
 
-       zval_ptr_dtor_nogc(free_op2);
        zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
        zval *property;
        zval *container;
 
        SAVE_OPLINE();
-       property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       property = opline->op2.zv;
 
        container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
        if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
 
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
+       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+
        if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
                EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
@@ -20246,22 +15534,22 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HAND
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
        zval *property;
        zval *container;
 
        SAVE_OPLINE();
-       property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       property = opline->op2.zv;
        container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
 
        if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
+       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
+
        if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
                EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
@@ -20270,17 +15558,17 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HAN
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
        zval *container;
-       zend_free_op free_op2;
+
        zval *offset;
 
        SAVE_OPLINE();
        container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-       offset  = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       offset  = opline->op2.zv;
 
        if ((IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
            UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
@@ -20290,7 +15578,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HAN
 
                /* here we are sure we are dealing with an object */
                do {
-                       if (IS_TMP_VAR == IS_CONST &&
+                       if (IS_CONST == IS_CONST &&
                                EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
                                zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
                                zend_object *zobj = Z_OBJ_P(container);
@@ -20310,7 +15598,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HAN
                                }
                        }
 
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
 
                        if (retval != EX_VAR(opline->result.var)) {
                                ZVAL_COPY(EX_VAR(opline->result.var), retval);
@@ -20318,24 +15606,23 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HAN
                } while (0);
        }
 
-       zval_ptr_dtor_nogc(free_op2);
        zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zval *container;
 
        if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
                /* Behave like FETCH_OBJ_W */
-               zend_free_op free_op1, free_op2;
+               zend_free_op free_op1;
                zval *property;
 
                SAVE_OPLINE();
-               property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+               property = opline->op2.zv;
                container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
 
         if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
@@ -20344,8 +15631,8 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_TMP_HANDLER(ZEND_OPCO
                if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
                }
-               zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op2);
+               zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+
                if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
                        EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
                }
@@ -20353,25 +15640,25 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_TMP_HANDLER(ZEND_OPCO
                CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
-               return ZEND_FETCH_OBJ_R_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return ZEND_FETCH_OBJ_R_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
        zval *container, *property;
 
        SAVE_OPLINE();
        container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-       property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       property = opline->op2.zv;
 
        if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
+       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
+
        if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
                EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
@@ -20380,22 +15667,55 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_LIST_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
+       zval *container;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
+
+       if (EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
+
+               zval *value = zend_fetch_dimension_address_inner(Z_ARRVAL_P(container), opline->op2.zv, IS_CONST, BP_VAR_R TSRMLS_CC);
+
+               ZVAL_COPY(EX_VAR(opline->result.var), value);
+       } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT) &&
+                  EXPECTED(Z_OBJ_HT_P(container)->read_dimension)) {
+               zval *result = EX_VAR(opline->result.var);
+               zval *retval = Z_OBJ_HT_P(container)->read_dimension(container, opline->op2.zv, BP_VAR_R, result TSRMLS_CC);
+
+               if (retval) {
+                       if (result != retval) {
+                               ZVAL_COPY(result, retval);
+                       }
+               } else {
+                       ZVAL_NULL(result);
+               }
+       } else {
+               ZVAL_NULL(EX_VAR(opline->result.var));
+       }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
        zval *object;
        zval *property_name;
 
        SAVE_OPLINE();
        object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-       property_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       property_name = opline->op2.zv;
 
        if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_VAR, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
+       zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_VAR, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+
        if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        /* assign_obj has two opcodes! */
        CHECK_EXCEPTION();
@@ -20403,7 +15723,7 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDL
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
@@ -20417,28 +15737,28 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDL
        }
        ZVAL_DEREF(object_ptr);
        if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
-               zend_free_op free_op2;
-               zval *property_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
 
-               zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_VAR, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op2);
+               zval *property_name = opline->op2.zv;
+
+               zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_VAR, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+
        } else {
-               zend_free_op free_op2, free_op_data1;
+               zend_free_op free_op_data1;
                zval  rv;
                zval *value;
-               zval *dim = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+               zval *dim = opline->op2.zv;
                zval *variable_ptr;
 
                if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
                    EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
                        zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
-                       zval_ptr_dtor_nogc(free_op2);
+
                        value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
                        zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
                        FREE_OP(free_op_data1);
                } else {
-                       zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_TMP_VAR TSRMLS_CC);
-                       zval_ptr_dtor_nogc(free_op2);
+                       zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_CONST TSRMLS_CC);
+
                        value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
                        ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
                        variable_ptr = Z_INDIRECT(rv);
@@ -20465,26 +15785,26 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDL
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
        zval *value;
        zval *variable_ptr;
 
        SAVE_OPLINE();
-       value = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       value = opline->op2.zv;
        variable_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
 
        if (IS_VAR == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
-               if (IS_TMP_VAR == IS_TMP_VAR) {
-                       zval_ptr_dtor_nogc(free_op2);
+               if (IS_CONST == IS_TMP_VAR) {
+
                }
                if (RETURN_VALUE_USED(opline)) {
                        ZVAL_NULL(EX_VAR(opline->result.var));
                }
        } else {
-               value = zend_assign_to_variable(variable_ptr, value, IS_TMP_VAR TSRMLS_CC);
+               value = zend_assign_to_variable(variable_ptr, value, IS_CONST TSRMLS_CC);
                if (RETURN_VALUE_USED(opline)) {
                        ZVAL_COPY(EX_VAR(opline->result.var), value);
                }
@@ -20497,11 +15817,11 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_A
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zval *function_name;
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
        zval *object;
        zend_function *fbc;
        zend_class_entry *called_scope;
@@ -20509,9 +15829,9 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE
 
        SAVE_OPLINE();
 
-       function_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       function_name = opline->op2.zv;
 
-       if (IS_TMP_VAR != IS_CONST &&
+       if (IS_CONST != IS_CONST &&
            UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                if (UNEXPECTED(EG(exception) != NULL)) {
                        HANDLE_EXCEPTION();
@@ -20525,12 +15845,12 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE
                uint32_t nesting = 1;
 
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       zval_ptr_dtor_nogc(free_op2);
+
                        HANDLE_EXCEPTION();
                }
 
                zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s",  Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
-               zval_ptr_dtor_nogc(free_op2);
+
                zval_ptr_dtor_nogc(free_op1);
 
                if (EG(exception) != NULL) {
@@ -20569,7 +15889,7 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE
        obj = Z_OBJ_P(object);
        called_scope = obj->ce;
 
-       if (IS_TMP_VAR != IS_CONST ||
+       if (IS_CONST != IS_CONST ||
            EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
            zend_object *orig_obj = obj;
 
@@ -20578,11 +15898,11 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE
                }
 
                /* First, locate the function. */
-               fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_TMP_VAR == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
+               fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_CONST == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
                if (UNEXPECTED(fbc == NULL)) {
                        zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
                }
-               if (IS_TMP_VAR == IS_CONST &&
+               if (IS_CONST == IS_CONST &&
                    EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
                    EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
                    EXPECTED(obj == orig_obj)) {
@@ -20599,14 +15919,13 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE
        EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
                fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
 
-       zval_ptr_dtor_nogc(free_op2);
        zval_ptr_dtor_nogc(free_op1);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zval *function_name;
@@ -20635,18 +15954,18 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_TMP_HANDLER(ZEND
        }
 
        if (IS_VAR == IS_CONST &&
-           IS_TMP_VAR == IS_CONST &&
+           IS_CONST == IS_CONST &&
            CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
                fbc = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
        } else if (IS_VAR != IS_CONST &&
-                  IS_TMP_VAR == IS_CONST &&
+                  IS_CONST == IS_CONST &&
                   (fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce))) {
                /* do nothing */
-       } else if (IS_TMP_VAR != IS_UNUSED) {
-               zend_free_op free_op2;
+       } else if (IS_CONST != IS_UNUSED) {
 
-               function_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-               if (IS_TMP_VAR != IS_CONST) {
+
+               function_name = opline->op2.zv;
+               if (IS_CONST != IS_CONST) {
                        if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                                if (UNEXPECTED(EG(exception) != NULL)) {
                                        HANDLE_EXCEPTION();
@@ -20658,12 +15977,12 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_TMP_HANDLER(ZEND
                if (ce->get_static_method) {
                        fbc = ce->get_static_method(ce, Z_STR_P(function_name) TSRMLS_CC);
                } else {
-                       fbc = zend_std_get_static_method(ce, Z_STR_P(function_name), ((IS_TMP_VAR == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
+                       fbc = zend_std_get_static_method(ce, Z_STR_P(function_name), ((IS_CONST == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
                }
                if (UNEXPECTED(fbc == NULL)) {
                        zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name->val, Z_STRVAL_P(function_name));
                }
-               if (IS_TMP_VAR == IS_CONST &&
+               if (IS_CONST == IS_CONST &&
                    EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
                    EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0)) {
                        if (IS_VAR == IS_CONST) {
@@ -20672,8 +15991,8 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_TMP_HANDLER(ZEND
                                CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), ce, fbc);
                        }
                }
-               if (IS_TMP_VAR != IS_CONST) {
-                       zval_ptr_dtor_nogc(free_op2);
+               if (IS_CONST != IS_CONST) {
+
                }
        } else {
                if (UNEXPECTED(ce->constructor == NULL)) {
@@ -20722,7 +16041,7 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_TMP_HANDLER(ZEND
        EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
                fbc, opline->extended_value, ce, object, EX(call) TSRMLS_CC);
 
-       if (IS_TMP_VAR == IS_UNUSED) {
+       if (IS_CONST == IS_UNUSED) {
                EX(call)->return_value = NULL;
        }
 
@@ -20730,23 +16049,105 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_TMP_HANDLER(ZEND
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_CASE_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_CONSTANT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
-       zval *result = EX_VAR(opline->result.var);
 
        SAVE_OPLINE();
-       fast_equal_function(result,
-                _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
-                _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       if (IS_VAR == IS_UNUSED) {
+               zend_constant *c;
+               zval *retval;
 
-       zval_ptr_dtor_nogc(free_op2);
+               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                       c = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+               } else if ((c = zend_quick_get_constant(opline->op2.zv + 1, opline->extended_value TSRMLS_CC)) == NULL) {
+                       if ((opline->extended_value & IS_CONSTANT_UNQUALIFIED) != 0) {
+                               char *actual = (char *)zend_memrchr(Z_STRVAL_P(opline->op2.zv), '\\', Z_STRLEN_P(opline->op2.zv));
+                               if (!actual) {
+                                       ZVAL_STR(EX_VAR(opline->result.var), zend_string_copy(Z_STR_P(opline->op2.zv)));
+                               } else {
+                                       actual++;
+                                       ZVAL_STRINGL(EX_VAR(opline->result.var),
+                                                       actual, Z_STRLEN_P(opline->op2.zv) - (actual - Z_STRVAL_P(opline->op2.zv)));
+                               }
+                               /* non-qualified constant - allow text substitution */
+                               zend_error(E_NOTICE, "Use of undefined constant %s - assumed '%s'",
+                                               Z_STRVAL_P(EX_VAR(opline->result.var)), Z_STRVAL_P(EX_VAR(opline->result.var)));
+                               CHECK_EXCEPTION();
+                               ZEND_VM_NEXT_OPCODE();
+                       } else {
+                               zend_error_noreturn(E_ERROR, "Undefined constant '%s'", Z_STRVAL_P(opline->op2.zv));
+                       }
+               } else {
+                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), c);
+               }
+               retval = EX_VAR(opline->result.var);
+               ZVAL_COPY_VALUE(retval, &c->value);
+               if (Z_OPT_COPYABLE_P(retval) || Z_OPT_REFCOUNTED_P(retval)) {
+                       if (Z_OPT_COPYABLE_P(retval)) {
+                               zval_copy_ctor_func(retval);
+                       } else {
+                               Z_ADDREF_P(retval);
+                       }
+               }
+       } else {
+               /* class constant */
+               zend_class_entry *ce;
+               zval *value;
+
+               if (IS_VAR == IS_CONST) {
+                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                               value = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+                               ZVAL_DEREF(value);
+                               ZVAL_DUP(EX_VAR(opline->result.var), value);
+                               goto constant_fetch_end;
+                       } else if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv))) {
+                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv));
+                       } else {
+                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op1.zv), opline->op1.zv + 1, 0 TSRMLS_CC);
+                               if (UNEXPECTED(EG(exception) != NULL)) {
+                                       HANDLE_EXCEPTION();
+                               }
+                               if (UNEXPECTED(ce == NULL)) {
+                                       zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
+                               }
+                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op1.zv), ce);
+                       }
+               } else {
+                       ce = Z_CE_P(EX_VAR(opline->op1.var));
+                       if ((value = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce)) != NULL) {
+                               ZVAL_DEREF(value);
+                               ZVAL_DUP(EX_VAR(opline->result.var), value);
+                               goto constant_fetch_end;
+                       }
+               }
+
+               if (EXPECTED((value = zend_hash_find(&ce->constants_table, Z_STR_P(opline->op2.zv))) != NULL)) {
+                       ZVAL_DEREF(value);
+                       if (Z_CONSTANT_P(value)) {
+                               EG(scope) = ce;
+                               zval_update_constant(value, 1 TSRMLS_CC);
+                               EG(scope) = EX(func)->op_array.scope;
+                       }
+                       if (IS_VAR == IS_CONST) {
+                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), value);
+                       } else {
+                               CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce, value);
+                       }
+                       ZVAL_DUP(EX_VAR(opline->result.var), value);
+               } else if (Z_STRLEN_P(opline->op2.zv) == sizeof("class")-1 && memcmp(Z_STRVAL_P(opline->op2.zv), "class", sizeof("class") - 1) == 0) {
+                       /* "class" is assigned as a case-sensitive keyword from zend_do_resolve_class_name */
+                       ZVAL_STR_COPY(EX_VAR(opline->result.var), ce->name);
+               } else {
+                       zend_error_noreturn(E_ERROR, "Undefined class constant '%s'", Z_STRVAL_P(opline->op2.zv));
+               }
+       }
+constant_fetch_end:
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
@@ -20781,9 +16182,9 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_TMP_HANDLER(ZEND_OPCOD
                }
        }
 
-       if (IS_TMP_VAR != IS_UNUSED) {
-               zend_free_op free_op2;
-               zval *offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       if (IS_CONST != IS_UNUSED) {
+
+               zval *offset = opline->op2.zv;
                zend_string *str;
                zend_ulong hval;
 
@@ -20799,7 +16200,7 @@ num_index:
                                break;
                        case IS_STRING:
                                str = Z_STR_P(offset);
-                               if (IS_TMP_VAR != IS_CONST) {
+                               if (IS_CONST != IS_CONST) {
                                        if (ZEND_HANDLE_NUMERIC(str, hval)) {
                                                goto num_index;
                                        }
@@ -20826,7 +16227,7 @@ str_index:
                                /* do nothing */
                                break;
                }
-               zval_ptr_dtor_nogc(free_op2);
+
        } else {
                zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
        }
@@ -20834,7 +16235,7 @@ str_index:
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        zval *array;
        uint32_t size;
@@ -20860,15 +16261,15 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDL
                ZEND_VM_NEXT_OPCODE();
 #if 0 || IS_VAR != IS_UNUSED
        } else {
-               return ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 #endif
        }
 }
 
-static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
        zval *container;
        zval *offset;
        zend_ulong hval;
@@ -20882,7 +16283,7 @@ static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLE
                ZVAL_DEREF(container);
        }
        SEPARATE_ZVAL_NOREF(container);
-       offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       offset = opline->op2.zv;
 
        if (IS_VAR != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
                HashTable *ht = Z_ARRVAL_P(container);
@@ -20898,7 +16299,7 @@ num_index_dim:
                                zend_hash_index_del(ht, hval);
                                break;
                        case IS_STRING:
-                               if (IS_TMP_VAR != IS_CONST) {
+                               if (IS_CONST != IS_CONST) {
                                        if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
                                                goto num_index_dim;
                                        }
@@ -20929,31 +16330,31 @@ num_index_dim:
                                zend_error(E_WARNING, "Illegal offset type in unset");
                                break;
                }
-               zval_ptr_dtor_nogc(free_op2);
+
        } else if (IS_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
                if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use object as array");
                }
-//???          if (IS_TMP_VAR == IS_CONST) {
+//???          if (IS_CONST == IS_CONST) {
 //???                  zval_copy_ctor(offset);
 //???          }
                Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op2);
+
        } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
                zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
                ZEND_VM_CONTINUE(); /* bailed out before */
        } else {
-               zval_ptr_dtor_nogc(free_op2);
+
        }
        if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
        zval *container;
        zval *offset;
 
@@ -20962,28 +16363,28 @@ static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLE
        if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
        }
-       offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       offset = opline->op2.zv;
 
        if (IS_VAR != IS_UNUSED) {
                ZVAL_DEREF(container);
        }
        if (IS_VAR == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
                if (Z_OBJ_HT_P(container)->unset_property) {
-                       Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+                       Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
                } else {
                        zend_error(E_NOTICE, "Trying to unset property of non-object");
                }
        }
-       zval_ptr_dtor_nogc(free_op2);
+
        if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
        zval *container;
        int result;
        zend_ulong hval;
@@ -20991,7 +16392,7 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_O
 
        SAVE_OPLINE();
        container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-       offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       offset = opline->op2.zv;
 
        if (IS_VAR != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
                HashTable *ht = Z_ARRVAL_P(container);
@@ -21001,7 +16402,7 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_O
 isset_again:
                if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
                        str = Z_STR_P(offset);
-                       if (IS_TMP_VAR != IS_CONST) {
+                       if (IS_CONST != IS_CONST) {
                                if (ZEND_HANDLE_NUMERIC(str, hval)) {
                                        goto num_index_prop;
                                }
@@ -21061,7 +16462,7 @@ num_index_prop:
 
                result = 0;
                if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
-                       if (IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) {
+                       if (IS_CONST & (IS_CV|IS_VAR)) {
                                ZVAL_DEREF(offset);
                        }
                        if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
@@ -21087,28 +16488,27 @@ num_index_prop:
                result = ((opline->extended_value & ZEND_ISSET) == 0);
        }
 
-       zval_ptr_dtor_nogc(free_op2);
        ZVAL_BOOL(EX_VAR(opline->result.var), result);
        zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
        zval *container;
        int result;
        zval *offset;
 
        SAVE_OPLINE();
        container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-       offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       offset = opline->op2.zv;
 
        if (IS_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
                if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
-                       result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+                       result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
                } else {
                        zend_error(E_NOTICE, "Trying to check property of non-object");
                        result = 0;
@@ -21120,14 +16520,52 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_
                result = ((opline->extended_value & ZEND_ISSET) == 0);
        }
 
-       zval_ptr_dtor_nogc(free_op2);
        ZVAL_BOOL(EX_VAR(opline->result.var), result);
        zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_YIELD_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INSTANCEOF_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *expr;
+       zend_bool result;
+
+       SAVE_OPLINE();
+       expr = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
+
+       if (Z_TYPE_P(expr) == IS_OBJECT) {
+               zend_class_entry *ce;
+
+               if (IS_CONST == IS_CONST) {
+                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+                       } else {
+                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, ZEND_FETCH_CLASS_NO_AUTOLOAD TSRMLS_CC);
+                               if (UNEXPECTED(ce == NULL)) {
+                                       ZVAL_FALSE(EX_VAR(opline->result.var));
+                                       zval_ptr_dtor_nogc(free_op1);
+                                       CHECK_EXCEPTION();
+                                       ZEND_VM_NEXT_OPCODE();
+                               }
+                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+                       }
+               } else {
+                       ce = Z_CE_P(EX_VAR(opline->op2.var));
+               }
+               result = instanceof_function(Z_OBJCE_P(expr), ce TSRMLS_CC);
+       } else {
+               result = 0;
+       }
+       ZVAL_BOOL(EX_VAR(opline->result.var), result);
+       zval_ptr_dtor_nogc(free_op1);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_YIELD_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
@@ -21209,21 +16647,21 @@ static int ZEND_FASTCALL  ZEND_YIELD_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_AR
        }
 
        /* Set the new yielded key */
-       if (IS_TMP_VAR != IS_UNUSED) {
-               zend_free_op free_op2;
-               zval *key = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       if (IS_CONST != IS_UNUSED) {
+
+               zval *key = opline->op2.zv;
 
                /* Consts, temporary variables and references need copying */
-               if (IS_TMP_VAR == IS_CONST) {
+               if (IS_CONST == IS_CONST) {
                        ZVAL_DUP(&generator->key, key);
-               } else if (IS_TMP_VAR == IS_TMP_VAR) {
+               } else if (IS_CONST == IS_TMP_VAR) {
                        ZVAL_COPY_VALUE(&generator->key, key);
-               } else if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && Z_ISREF_P(key)) {
+               } else if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) && Z_ISREF_P(key)) {
                        ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
 
                } else {
                        ZVAL_COPY_VALUE(&generator->key, key);
-                       if (IS_TMP_VAR == IS_CV) {
+                       if (IS_CONST == IS_CV) {
                                if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
                        }
                }
@@ -21259,27 +16697,27 @@ static int ZEND_FASTCALL  ZEND_YIELD_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_AR
        ZEND_VM_RETURN();
 }
 
-static int ZEND_FASTCALL  ZEND_POW_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_POW_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
 
        SAVE_OPLINE();
        pow_function(EX_VAR(opline->result.var),
                _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               opline->op2.zv TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
-       zval_ptr_dtor_nogc(free_op2);
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_POW_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_POW_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_binary_assign_op_helper_SPEC_VAR_TMP(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_binary_assign_op_helper_SPEC_VAR_CONST(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_MOD_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_MOD_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
@@ -21287,14 +16725,14 @@ static int ZEND_FASTCALL  ZEND_MOD_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS
        SAVE_OPLINE();
        fast_mod_function(EX_VAR(opline->result.var),
                _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
        zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_SL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
@@ -21302,14 +16740,14 @@ static int ZEND_FASTCALL  ZEND_SL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
        SAVE_OPLINE();
        shift_left_function(EX_VAR(opline->result.var),
                _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
        zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_SR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
@@ -21317,14 +16755,14 @@ static int ZEND_FASTCALL  ZEND_SR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
        SAVE_OPLINE();
        shift_right_function(EX_VAR(opline->result.var),
                _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
        zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
@@ -21332,14 +16770,14 @@ static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_A
        SAVE_OPLINE();
        concat_function(EX_VAR(opline->result.var),
                _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
        zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
@@ -21347,14 +16785,14 @@ static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HAN
        SAVE_OPLINE();
        fast_is_identical_function(EX_VAR(opline->result.var),
                _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
        zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
@@ -21363,14 +16801,14 @@ static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE
        SAVE_OPLINE();
        fast_is_not_identical_function(result,
                _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
        zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
@@ -21378,14 +16816,14 @@ static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_AR
        SAVE_OPLINE();
        bitwise_or_function(EX_VAR(opline->result.var),
                _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
        zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
@@ -21393,14 +16831,14 @@ static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_A
        SAVE_OPLINE();
        bitwise_and_function(EX_VAR(opline->result.var),
                _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
        zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
@@ -21408,14 +16846,14 @@ static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_A
        SAVE_OPLINE();
        bitwise_xor_function(EX_VAR(opline->result.var),
                _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
        zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
@@ -21423,19 +16861,19 @@ static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER
        SAVE_OPLINE();
        boolean_xor_function(EX_VAR(opline->result.var),
                _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
        zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2, free_op_data1;
        zval *object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-       zval *property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+       zval *property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
        zval *value;
        zval *zptr;
 
@@ -21461,7 +16899,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(int (*bin
                /* here we are sure we are dealing with an object */
                if (opline->extended_value == ZEND_ASSIGN_OBJ
                        && EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-                       && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+                       && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
 
                        ZVAL_DEREF(zptr);
                        SEPARATE_ZVAL_NOREF(zptr);
@@ -21476,7 +16914,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(int (*bin
 
                        if (opline->extended_value == ZEND_ASSIGN_OBJ) {
                                if (Z_OBJ_HT_P(object)->read_property) {
-                                       z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+                                       z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
                                }
                        } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
                                if (Z_OBJ_HT_P(object)->read_dimension) {
@@ -21497,7 +16935,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(int (*bin
                                SEPARATE_ZVAL_IF_NOT_REF(z);
                                binary_op(z, z, value TSRMLS_CC);
                                if (opline->extended_value == ZEND_ASSIGN_OBJ) {
-                                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+                                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
                                } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
                                        Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
                                }
@@ -21524,7 +16962,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(int (*bin
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2, free_op_data1;
@@ -21543,11 +16981,11 @@ static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(int (*bin
                if (IS_VAR == IS_VAR && !(free_op1 != NULL)) {
                        Z_ADDREF_P(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
                }
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else {
-               zval *dim = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+               zval *dim = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
 
-               zend_fetch_dimension_address_RW(&rv, container, dim, IS_VAR TSRMLS_CC);
+               zend_fetch_dimension_address_RW(&rv, container, dim, IS_TMP_VAR TSRMLS_CC);
                value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
                ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
                var_ptr = Z_INDIRECT(rv);
@@ -21580,7 +17018,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(int (*bin
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
@@ -21588,7 +17026,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_VAR(int (*binary_
        zval *value;
 
        SAVE_OPLINE();
-       value = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+       value = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
        var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
 
        if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
@@ -21616,1778 +17054,1301 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_VAR(int (*binary_
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_ADD_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_ADD_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_VAR_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SUB_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_SUB_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_VAR_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_MUL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_MUL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_VAR_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_DIV_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_DIV_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_VAR_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_MOD_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_MOD_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_VAR_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_SL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_VAR_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_SR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_VAR_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_CONCAT_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_CONCAT_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_VAR_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_OR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_OR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_VAR_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_AND_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_AND_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_VAR_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_VAR_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_VAR_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_VAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *object;
-       zval *property;
-       zval *retval;
-       zval *zptr;
+       zval *container;
 
        SAVE_OPLINE();
-       object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-       retval = EX_VAR(opline->result.var);
+       container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+       zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
+       zval_ptr_dtor_nogc(free_op1);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
-       }
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1, free_op2;
+       zval *container;
 
-       if (IS_VAR != IS_UNUSED) {
-               object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
-       }
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
 
-       if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
-               zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-               zval_ptr_dtor_nogc(free_op2);
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(retval);
-               }
-               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
+       ZVAL_DEREF(container);
+       zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
+       if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+       }
+       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       /* here we are sure we are dealing with an object */
-
-       if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
-
-               ZVAL_DEREF(zptr);
-               SEPARATE_ZVAL_NOREF(zptr);
-
-               incdec_op(zptr);
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_COPY(retval, zptr);
-               }
-       } else {
-               zval rv;
-
-               if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
-                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1, free_op2;
+       zval *container;
 
-                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
-                               zval rv;
-                               zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
 
-                               if (Z_REFCOUNT_P(z) == 0) {
-                                       zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
-                               }
-                               ZVAL_COPY_VALUE(z, value);
-                       }
-                       if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
-                       SEPARATE_ZVAL_IF_NOT_REF(z);
-                       incdec_op(z);
-                       ZVAL_COPY_VALUE(retval, z);
-                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
-                       SELECTIVE_PZVAL_LOCK(retval, opline);
-                       zval_ptr_dtor(z);
-               } else {
-                       zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-                       if (RETURN_VALUE_USED(opline)) {
-                               ZVAL_NULL(retval);
-                       }
-               }
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-
+       ZVAL_DEREF(container);
+       zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op2);
+       if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+       }
        if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_PRE_INC_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_pre_incdec_property_helper_SPEC_VAR_VAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+       USE_OPLINE
+       zend_free_op free_op1, free_op2;
+       zval *container;
 
-static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_pre_incdec_property_helper_SPEC_VAR_VAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       SAVE_OPLINE();
+       container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+       zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
+       zval_ptr_dtor_nogc(free_op1);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_VAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zval *container;
        zend_free_op free_op1, free_op2;
-       zval *object;
-       zval *property;
-       zval *retval;
-       zval *zptr;
 
        SAVE_OPLINE();
-       object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-       retval = EX_VAR(opline->result.var);
 
-       if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
+       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+        if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
+            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+        }
+               container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+               }
+               ZVAL_DEREF(container);
+               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
+               if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
+                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+               }
+               zval_ptr_dtor_nogc(free_op2);
+               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+       } else {
+               if (IS_TMP_VAR == IS_UNUSED) {
+                       zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
+               }
+               container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
+               zval_ptr_dtor_nogc(free_op2);
+               zval_ptr_dtor_nogc(free_op1);
        }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       if (IS_VAR != IS_UNUSED) {
-               object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
-       }
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_UNSET_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1, free_op2;
+       zval *container;
 
-       if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
-               zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-               zval_ptr_dtor_nogc(free_op2);
-               ZVAL_NULL(retval);
-               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+       }
+       ZVAL_DEREF(container);
+       zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
+       if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
+       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       /* here we are sure we are dealing with an object */
+static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *object_ptr;
 
-       if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
 
-               ZVAL_DEREF(zptr);
-               ZVAL_COPY_VALUE(retval, zptr);
-               zval_opt_copy_ctor(zptr);
+       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+       }
+       ZVAL_DEREF(object_ptr);
+       if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
+               zend_free_op free_op2;
+               zval *property_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
 
-               incdec_op(zptr);
+               zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_VAR, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+               zval_ptr_dtor_nogc(free_op2);
        } else {
-               if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
-                       zval rv;
-                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
-                       zval z_copy;
-
-                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
-                               zval rv;
-                               zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+               zend_free_op free_op2, free_op_data1;
+               zval  rv;
+               zval *value;
+               zval *dim = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+               zval *variable_ptr;
 
-                               if (Z_REFCOUNT_P(z) == 0) {
-                                       zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
+               if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
+                   EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
+                       zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
+                       zval_ptr_dtor_nogc(free_op2);
+                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+                       zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
+                       FREE_OP(free_op_data1);
+               } else {
+                       zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_TMP_VAR TSRMLS_CC);
+                       zval_ptr_dtor_nogc(free_op2);
+                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+                       ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+                       variable_ptr = Z_INDIRECT(rv);
+                       if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
+                               FREE_OP(free_op_data1);
+                               if (RETURN_VALUE_USED(opline)) {
+                                       ZVAL_NULL(EX_VAR(opline->result.var));
+                               }
+                       } else {
+                               value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
+                               if ((opline+1)->op1_type == IS_VAR) {
+                                       FREE_OP(free_op_data1);
+                               }
+                               if (RETURN_VALUE_USED(opline)) {
+                                       ZVAL_COPY(EX_VAR(opline->result.var), value);
                                }
-                               ZVAL_COPY_VALUE(z, value);
                        }
-                       ZVAL_DUP(retval, z);
-                       ZVAL_DUP(&z_copy, z);
-                       incdec_op(&z_copy);
-                       if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
-                       Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
-                       zval_ptr_dtor(&z_copy);
-                       zval_ptr_dtor(z);
-               } else {
-                       zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-                       ZVAL_NULL(retval);
                }
        }
-
-       zval_ptr_dtor_nogc(free_op2);
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+       /* assign_dim has two opcodes! */
        CHECK_EXCEPTION();
+       ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_POST_INC_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_post_incdec_property_helper_SPEC_VAR_VAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+       USE_OPLINE
+       zend_free_op free_op1, free_op2;
+       zval *value;
+       zval *variable_ptr;
 
-static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_post_incdec_property_helper_SPEC_VAR_VAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       SAVE_OPLINE();
+       value = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       variable_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
+               if (IS_TMP_VAR == IS_TMP_VAR) {
+                       zval_ptr_dtor_nogc(free_op2);
+               }
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
+       } else {
+               value = zend_assign_to_variable(variable_ptr, value, IS_TMP_VAR TSRMLS_CC);
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_COPY(EX_VAR(opline->result.var), value);
+               }
+               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+       }
+
+       /* zend_assign_to_variable() always takes care of op2, never free it! */
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_VAR_VAR(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_YIELD_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
-       zval *varname;
-       zval *retval;
-       zend_string *name;
-       HashTable *target_symbol_table;
 
-       SAVE_OPLINE();
-       varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+       /* The generator object is stored in EX(return_value) */
+       zend_generator *generator = (zend_generator *) EX(return_value);
 
-       if (IS_VAR == IS_CONST) {
-               name = Z_STR_P(varname);
-       } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
-               name = Z_STR_P(varname);
-               zend_string_addref(name);
-       } else {
-               name = zval_get_string(varname);
+       if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
+               zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
        }
 
+       /* Destroy the previously yielded value */
+       zval_ptr_dtor(&generator->value);
+
+       /* Destroy the previously yielded key */
+       zval_ptr_dtor(&generator->key);
+
+       /* Set the new yielded value */
        if (IS_VAR != IS_UNUSED) {
-               zend_class_entry *ce;
+               zend_free_op free_op1;
 
-               if (IS_VAR == IS_CONST) {
-                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+               if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
+                       /* Constants and temporary variables aren't yieldable by reference,
+                        * but we still allow them with a notice. */
+                       if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
+                               zval *value;
+
+                               zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+
+                               value = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+                               ZVAL_COPY_VALUE(&generator->value, value);
+                               if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
+
+                               /* Temporary variables don't need ctor copying */
+                               if (IS_VAR != IS_TMP_VAR) {
+                                       zval_opt_copy_ctor(&generator->value);
+                               }
                        } else {
-                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                               if (UNEXPECTED(ce == NULL)) {
-                                       if (IS_VAR != IS_CONST) {
-                                               zend_string_release(name);
-                                       }
-                                       zval_ptr_dtor_nogc(free_op1);
-                                       CHECK_EXCEPTION();
-                                       ZEND_VM_NEXT_OPCODE();
+                               zval *value_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+
+                               if (IS_VAR == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+                                       zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
                                }
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
-                       }
-               } else {
-                       ce = Z_CE_P(EX_VAR(opline->op2.var));
-               }
-               retval = zend_std_get_static_property(ce, name, 0, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op1);
-       } else {
-               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-               retval = zend_hash_find(target_symbol_table, name);
-               if (retval == NULL) {
-                       switch (type) {
-                               case BP_VAR_R:
-                               case BP_VAR_UNSET:
-                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                       /* break missing intentionally */
-                               case BP_VAR_IS:
-                                       retval = &EG(uninitialized_zval);
-                                       break;
-                               case BP_VAR_RW:
-                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                       /* break missing intentionally */
-                               case BP_VAR_W:
-                                       retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
-                                       break;
-                               EMPTY_SWITCH_DEFAULT_CASE()
-                       }
-               /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
-               } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
-                       retval = Z_INDIRECT_P(retval);
-                       if (Z_TYPE_P(retval) == IS_UNDEF) {
-                               switch (type) {
-                                       case BP_VAR_R:
-                                       case BP_VAR_UNSET:
-                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                               /* break missing intentionally */
-                                       case BP_VAR_IS:
-                                               retval = &EG(uninitialized_zval);
-                                               break;
-                                       case BP_VAR_RW:
-                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                               /* break missing intentionally */
-                                       case BP_VAR_W:
-                                               ZVAL_NULL(retval);
-                                               break;
-                                       EMPTY_SWITCH_DEFAULT_CASE()
+
+                               /* If a function call result is yielded and the function did
+                                * not return by reference we throw a notice. */
+                               if (IS_VAR == IS_VAR &&
+                                   (value_ptr == &EG(uninitialized_zval) ||
+                                    (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+                                     !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+                                       zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+                               } else {
+                                       ZVAL_MAKE_REF(value_ptr);
                                }
-                       }
-               }
-               if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
-                       if (Z_CONSTANT_P(retval)) {
-                               zval_update_constant(retval, 1 TSRMLS_CC);
-                       }
-               } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
-                       zval_ptr_dtor_nogc(free_op1);
-               }
-       }
+                               ZVAL_COPY(&generator->value, value_ptr);
 
-       if (IS_VAR != IS_CONST) {
-               zend_string_release(name);
-       }
+                               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+                       }
+               } else {
+                       zval *value = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
 
-       ZEND_ASSERT(retval != NULL);
-       if (type == BP_VAR_R || type == BP_VAR_IS) {
-               if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
-                       ZVAL_UNREF(retval);
+                       /* Consts, temporary variables and references need copying */
+                       if (IS_VAR == IS_CONST) {
+                               ZVAL_DUP(&generator->value, value);
+                       } else if (IS_VAR == IS_TMP_VAR) {
+                               ZVAL_COPY_VALUE(&generator->value, value);
+            } else if ((IS_VAR == IS_CV || IS_VAR == IS_VAR) && Z_ISREF_P(value)) {
+                               ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
+                               zval_ptr_dtor_nogc(free_op1);
+                       } else {
+                               ZVAL_COPY_VALUE(&generator->value, value);
+                               if (IS_VAR == IS_CV) {
+                                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+                               }
+                       }
                }
-               ZVAL_COPY(EX_VAR(opline->result.var), retval);
        } else {
-               ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
+               /* If no value was specified yield null */
+               ZVAL_NULL(&generator->value);
        }
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
 
-static int ZEND_FASTCALL  ZEND_FETCH_R_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_VAR_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+       /* Set the new yielded key */
+       if (IS_TMP_VAR != IS_UNUSED) {
+               zend_free_op free_op2;
+               zval *key = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
 
-static int ZEND_FASTCALL  ZEND_FETCH_W_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_VAR_VAR(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+               /* Consts, temporary variables and references need copying */
+               if (IS_TMP_VAR == IS_CONST) {
+                       ZVAL_DUP(&generator->key, key);
+               } else if (IS_TMP_VAR == IS_TMP_VAR) {
+                       ZVAL_COPY_VALUE(&generator->key, key);
+               } else if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && Z_ISREF_P(key)) {
+                       ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
 
-static int ZEND_FASTCALL  ZEND_FETCH_RW_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_VAR_VAR(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+               } else {
+                       ZVAL_COPY_VALUE(&generator->key, key);
+                       if (IS_TMP_VAR == IS_CV) {
+                               if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
+                       }
+               }
 
-static int ZEND_FASTCALL  ZEND_FETCH_FUNC_ARG_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+               if (Z_TYPE(generator->key) == IS_LONG
+                   && Z_LVAL(generator->key) > generator->largest_used_integer_key
+               ) {
+                       generator->largest_used_integer_key = Z_LVAL(generator->key);
+               }
+       } else {
+               /* If no key was specified we use auto-increment keys */
+               generator->largest_used_integer_key++;
+               ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
+       }
 
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-               return zend_fetch_var_address_helper_SPEC_VAR_VAR(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       if (RETURN_VALUE_USED(opline)) {
+               /* If the return value of yield is used set the send
+                * target and initialize it to NULL */
+               generator->send_target = EX_VAR(opline->result.var);
+               ZVAL_NULL(generator->send_target);
        } else {
-               return zend_fetch_var_address_helper_SPEC_VAR_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               generator->send_target = NULL;
        }
-}
 
-static int ZEND_FASTCALL  ZEND_FETCH_UNSET_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_VAR_VAR(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+       /* We increment to the next op, so we are at the correct position when the
+        * generator is resumed. */
+       ZEND_VM_INC_OPCODE();
 
-static int ZEND_FASTCALL  ZEND_FETCH_IS_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_VAR_VAR(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       /* The GOTO VM uses a local opline variable. We need to set the opline
+        * variable in execute_data so we don't resume at an old position. */
+       SAVE_OPLINE();
+
+       ZEND_VM_RETURN();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_POW_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *container;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-       zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
+       pow_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
+               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
+       zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_POW_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       USE_OPLINE
-       zend_free_op free_op1, free_op2;
-       zval *container;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-       }
-       ZVAL_DEREF(container);
-       zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
-       if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-       }
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       return zend_binary_assign_op_helper_SPEC_VAR_TMP(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_MOD_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *container;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-       }
-       ZVAL_DEREF(container);
-       zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+       fast_mod_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
        zval_ptr_dtor_nogc(free_op2);
-       if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-       }
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *container;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-       zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
+       shift_left_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
+       zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *container;
        zend_free_op free_op1, free_op2;
 
        SAVE_OPLINE();
-
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-        if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
-            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
-        }
-               container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-               }
-               ZVAL_DEREF(container);
-               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
-               if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
-                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-               }
-               zval_ptr_dtor_nogc(free_op2);
-               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       } else {
-               if (IS_VAR == IS_UNUSED) {
-                       zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
-               }
-               container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op2);
-               zval_ptr_dtor_nogc(free_op1);
-       }
+       shift_right_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
+       zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_UNSET_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *container;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-       }
-       ZVAL_DEREF(container);
-       zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+       concat_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
        zval_ptr_dtor_nogc(free_op2);
-       if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-       }
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
-       zval *container;
-       zend_free_op free_op2;
-       zval *offset;
+       zend_free_op free_op1, free_op2;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-       offset  = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
-       if ((IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
-           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
-               zend_error(E_NOTICE, "Trying to get property of non-object");
-               ZVAL_NULL(EX_VAR(opline->result.var));
-       } else {
-               zval *retval;
-
-               /* here we are sure we are dealing with an object */
-               do {
-                       if (IS_VAR == IS_CONST &&
-                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
-                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
-                               zend_object *zobj = Z_OBJ_P(container);
-
-                               if (EXPECTED(prop_info)) {
-                                       retval = OBJ_PROP(zobj, prop_info->offset);
-                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               } else if (EXPECTED(zobj->properties != NULL)) {
-                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
-                                       if (EXPECTED(retval)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               }
-                       }
-
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
-
-                       if (retval != EX_VAR(opline->result.var)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                       }
-               } while (0);
-       }
-
-       zval_ptr_dtor_nogc(free_op2);
+       fast_is_identical_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
+       zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *property;
-       zval *container;
+       zval *result = EX_VAR(opline->result.var);
 
        SAVE_OPLINE();
-       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
-       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
-       }
-
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+       fast_is_not_identical_function(result,
+               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
        zval_ptr_dtor_nogc(free_op2);
-       if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-       }
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *property;
-       zval *container;
 
        SAVE_OPLINE();
-       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
-       }
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
+       bitwise_or_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
        zval_ptr_dtor_nogc(free_op2);
-       if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-       }
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
-       zval *container;
-       zend_free_op free_op2;
-       zval *offset;
+       zend_free_op free_op1, free_op2;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-       offset  = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
-       if ((IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
-           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
-               ZVAL_NULL(EX_VAR(opline->result.var));
-       } else {
-               zval *retval;
-
-               /* here we are sure we are dealing with an object */
-               do {
-                       if (IS_VAR == IS_CONST &&
-                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
-                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
-                               zend_object *zobj = Z_OBJ_P(container);
-
-                               if (EXPECTED(prop_info)) {
-                                       retval = OBJ_PROP(zobj, prop_info->offset);
-                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               } else if (EXPECTED(zobj->properties != NULL)) {
-                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
-                                       if (EXPECTED(retval)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               }
-                       }
-
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
-
-                       if (retval != EX_VAR(opline->result.var)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                       }
-               } while (0);
-       }
-
-       zval_ptr_dtor_nogc(free_op2);
+       bitwise_and_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op1);
+       zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *container;
-
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-               /* Behave like FETCH_OBJ_W */
-               zend_free_op free_op1, free_op2;
-               zval *property;
-
-               SAVE_OPLINE();
-               property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-               container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-        if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
-            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
-        }
-               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
-               }
-               zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op2);
-               if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
-                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-               }
-               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       } else {
-               return ZEND_FETCH_OBJ_R_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *container, *property;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
-       }
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
+       bitwise_xor_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
        zval_ptr_dtor_nogc(free_op2);
-       if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-       }
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *object;
-       zval *property_name;
 
        SAVE_OPLINE();
-       object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-       property_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-       }
-       zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_VAR, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+       boolean_xor_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1),
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
        zval_ptr_dtor_nogc(free_op2);
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       /* assign_obj has two opcodes! */
        CHECK_EXCEPTION();
-       ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
-       zval *object_ptr;
+       zend_free_op free_op1, free_op2, free_op_data1;
+       zval *object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+       zval *property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+       zval *value;
+       zval *zptr;
 
-       SAVE_OPLINE();
-       object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+       if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+       }
 
-       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+       if (IS_VAR != IS_UNUSED) {
+               object = make_real_object(object TSRMLS_CC);
        }
-       ZVAL_DEREF(object_ptr);
-       if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
-               zend_free_op free_op2;
-               zval *property_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-               zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_VAR, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+
+       if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+               zend_error(E_WARNING, "Attempt to assign property of non-object");
                zval_ptr_dtor_nogc(free_op2);
+               FREE_OP(free_op_data1);
+
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
        } else {
-               zend_free_op free_op2, free_op_data1;
-               zval  rv;
-               zval *value;
-               zval *dim = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
-               zval *variable_ptr;
+               /* here we are sure we are dealing with an object */
+               if (opline->extended_value == ZEND_ASSIGN_OBJ
+                       && EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+                       && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
 
-               if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
-                   EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
-                       zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
-                       zval_ptr_dtor_nogc(free_op2);
-                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-                       zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
-                       FREE_OP(free_op_data1);
+                       ZVAL_DEREF(zptr);
+                       SEPARATE_ZVAL_NOREF(zptr);
+
+                       binary_op(zptr, zptr, value TSRMLS_CC);
+                       if (RETURN_VALUE_USED(opline)) {
+                               ZVAL_COPY(EX_VAR(opline->result.var), zptr);
+                       }
                } else {
-                       zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_VAR TSRMLS_CC);
-                       zval_ptr_dtor_nogc(free_op2);
-                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-                       ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
-                       variable_ptr = Z_INDIRECT(rv);
-                       if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
-                               FREE_OP(free_op_data1);
+                       zval *z = NULL;
+                       zval rv;
+
+                       if (opline->extended_value == ZEND_ASSIGN_OBJ) {
+                               if (Z_OBJ_HT_P(object)->read_property) {
+                                       z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+                               }
+                       } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
+                               if (Z_OBJ_HT_P(object)->read_dimension) {
+                                       z = Z_OBJ_HT_P(object)->read_dimension(object, property, BP_VAR_R, &rv TSRMLS_CC);
+                               }
+                       }
+                       if (z) {
+                               if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                                       zval rv;
+                                       zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+
+                                       if (Z_REFCOUNT_P(z) == 0) {
+                                               zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
+                                       }
+                                       ZVAL_COPY_VALUE(z, value);
+                               }
+//???                          if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
+                               SEPARATE_ZVAL_IF_NOT_REF(z);
+                               binary_op(z, z, value TSRMLS_CC);
+                               if (opline->extended_value == ZEND_ASSIGN_OBJ) {
+                                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+                               } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
+                                       Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
+                               }
                                if (RETURN_VALUE_USED(opline)) {
-                                       ZVAL_NULL(EX_VAR(opline->result.var));
+                                       ZVAL_COPY(EX_VAR(opline->result.var), z);
                                }
+                               zval_ptr_dtor(z);
                        } else {
-                               value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
-                               if ((opline+1)->op1_type == IS_VAR) {
-                                       FREE_OP(free_op_data1);
-                               }
+                               zend_error(E_WARNING, "Attempt to assign property of non-object");
                                if (RETURN_VALUE_USED(opline)) {
-                                       ZVAL_COPY(EX_VAR(opline->result.var), value);
+                                       ZVAL_NULL(EX_VAR(opline->result.var));
                                }
                        }
                }
+
+               zval_ptr_dtor_nogc(free_op2);
+               FREE_OP(free_op_data1);
        }
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       /* assign_dim has two opcodes! */
+
+       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+       /* assign_obj has two opcodes! */
        CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
-       zval *value;
-       zval *variable_ptr;
+       zend_free_op free_op1, free_op2, free_op_data1;
+       zval *var_ptr, rv;
+       zval *value, *container;
 
        SAVE_OPLINE();
-       value = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
-       variable_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
-               if (IS_VAR == IS_TMP_VAR) {
-                       zval_ptr_dtor_nogc(free_op2);
+       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+       }
+       if (IS_VAR != IS_UNUSED) {
+               ZVAL_DEREF(container);
+       }
+       if (IS_VAR == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+               if (IS_VAR == IS_VAR && !(free_op1 != NULL)) {
+                       Z_ADDREF_P(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
                }
-               if (RETURN_VALUE_USED(opline)) {
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else {
+               zval *dim = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+
+               zend_fetch_dimension_address_RW(&rv, container, dim, IS_VAR TSRMLS_CC);
+               value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+               ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+               var_ptr = Z_INDIRECT(rv);
+       }
+
+       if (UNEXPECTED(var_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
+       }
+
+       if (UNEXPECTED(var_ptr == &EG(error_zval))) {
+               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
                        ZVAL_NULL(EX_VAR(opline->result.var));
                }
        } else {
-               value = zend_assign_to_variable(variable_ptr, value, IS_VAR TSRMLS_CC);
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_COPY(EX_VAR(opline->result.var), value);
+               ZVAL_DEREF(var_ptr);
+               SEPARATE_ZVAL_NOREF(var_ptr);
+
+               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
+
+               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
                }
-               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        }
 
-       /* zend_assign_to_variable() always takes care of op2, never free it! */
-       zval_ptr_dtor_nogc(free_op2);
-
+       zval_ptr_dtor_nogc(free_op2);
+       FREE_OP(free_op_data1);
+       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
+       ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_REF_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *variable_ptr;
-       zval *value_ptr;
+       zval *var_ptr;
+       zval *value;
 
        SAVE_OPLINE();
-       value_ptr = _get_zval_ptr_ptr_var(opline->op2.var, execute_data, &free_op2);
+       value = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+       var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
 
-       if (IS_VAR == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
-       }
-       if (IS_VAR == IS_VAR &&
-           (value_ptr == &EG(uninitialized_zval) ||
-            (opline->extended_value == ZEND_RETURNS_FUNCTION &&
-             !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
-               if (!(free_op2 != NULL)) {
-                       PZVAL_LOCK(value_ptr); /* undo the effect of get_zval_ptr_ptr() */
-               }
-               zend_error(E_STRICT, "Only variables should be assigned by reference");
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       if (free_op2) {zval_ptr_dtor_nogc(free_op2);};
-                       HANDLE_EXCEPTION();
-               }
-               return ZEND_ASSIGN_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (IS_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
-               if (!(free_op2 != NULL)) {
-                       PZVAL_LOCK(value_ptr);
-               }
+       if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
        }
 
-       variable_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-       if (IS_VAR == IS_VAR && UNEXPECTED(variable_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
-       }
-       if (IS_VAR == IS_VAR &&
-           UNEXPECTED(Z_TYPE_P(EX_VAR(opline->op1.var)) != IS_INDIRECT) &&
-           UNEXPECTED(!Z_ISREF_P(variable_ptr))) {
-               zend_error_noreturn(E_ERROR, "Cannot assign by reference to overloaded object");
-       }
-       if ((IS_VAR == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) ||
-           (IS_VAR == IS_VAR && UNEXPECTED(value_ptr == &EG(error_zval)))) {
-               variable_ptr = &EG(uninitialized_zval);
+       if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
        } else {
-               zend_assign_to_variable_reference(variable_ptr, value_ptr TSRMLS_CC);
-       }
+               ZVAL_DEREF(var_ptr);
+               SEPARATE_ZVAL_NOREF(var_ptr);
 
-       if (IS_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
-               if (!(free_op2 != NULL)) {
-                       Z_DELREF_P(variable_ptr);
-               }
-       }
+               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
 
-       if (RETURN_VALUE_USED(opline)) {
-               ZVAL_COPY(EX_VAR(opline->result.var), variable_ptr);
+               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+               }
        }
 
+       zval_ptr_dtor_nogc(free_op2);
        if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       if (free_op2) {zval_ptr_dtor_nogc(free_op2);};
-
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_ADD_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *function_name;
-       zend_free_op free_op1, free_op2;
-       zval *object;
-       zend_function *fbc;
-       zend_class_entry *called_scope;
-       zend_object *obj;
-
-       SAVE_OPLINE();
-
-       function_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if (IS_VAR != IS_CONST &&
-           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       HANDLE_EXCEPTION();
-               }
-               zend_error_noreturn(E_ERROR, "Method name must be a string");
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_VAR_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
+}
 
-       object = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
-               uint32_t nesting = 1;
-
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       zval_ptr_dtor_nogc(free_op2);
-                       HANDLE_EXCEPTION();
-               }
-
-               zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s",  Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
-               zval_ptr_dtor_nogc(free_op2);
-               zval_ptr_dtor_nogc(free_op1);
-
-               if (EG(exception) != NULL) {
-                       HANDLE_EXCEPTION();
-               }
-
-               /* No exception raised: Skip over arguments until fcall opcode with correct
-                * nesting level. Return NULL (except when return value unused) */
-               do {
-                       opline++;
-                       if (opline->opcode == ZEND_INIT_FCALL ||
-                               opline->opcode == ZEND_INIT_FCALL_BY_NAME ||
-                               opline->opcode == ZEND_INIT_NS_FCALL_BY_NAME ||
-                               opline->opcode == ZEND_INIT_METHOD_CALL ||
-                               opline->opcode == ZEND_INIT_STATIC_METHOD_CALL ||
-                               opline->opcode == ZEND_INIT_USER_CALL ||
-                               opline->opcode == ZEND_NEW
-                       ) {
-                               nesting++;
-                       } else if (opline->opcode == ZEND_DO_FCALL) {
-                               nesting--;
-                       }
-               } while (nesting);
-
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
-               }
+static int ZEND_FASTCALL  ZEND_ASSIGN_SUB_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-               /* We've skipped EXT_FCALL_BEGIND, so also skip the ending opcode */
-               if ((opline + 1)->opcode == ZEND_EXT_FCALL_END) {
-                       opline++;
-               }
-               ZEND_VM_JMP(++opline);
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_VAR_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
+}
 
-       obj = Z_OBJ_P(object);
-       called_scope = obj->ce;
-
-       if (IS_VAR != IS_CONST ||
-           EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
-           zend_object *orig_obj = obj;
-
-               if (UNEXPECTED(obj->handlers->get_method == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Object does not support method calls");
-               }
-
-               /* First, locate the function. */
-               fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_VAR == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
-               if (UNEXPECTED(fbc == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
-               }
-               if (IS_VAR == IS_CONST &&
-                   EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
-                   EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
-                   EXPECTED(obj == orig_obj)) {
-                       CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope, fbc);
-               }
-       }
+static int ZEND_FASTCALL  ZEND_ASSIGN_MUL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_STATIC) != 0)) {
-               obj = NULL;
-       } else {
-               GC_REFCOUNT(obj)++; /* For $this pointer */
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_VAR_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
+}
 
-       EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
-               fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
-
-       zval_ptr_dtor_nogc(free_op2);
-       zval_ptr_dtor_nogc(free_op1);
+static int ZEND_FASTCALL  ZEND_ASSIGN_DIV_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_VAR_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_MOD_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *function_name;
-       zend_class_entry *ce;
-       zend_object *object;
-       zend_function *fbc;
-
-       SAVE_OPLINE();
 
-       if (IS_VAR == IS_CONST) {
-               /* no function found. try a static method in class */
-               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv))) {
-                       ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv));
-               } else {
-                       ce = zend_fetch_class_by_name(Z_STR_P(opline->op1.zv), opline->op1.zv + 1, ZEND_FETCH_CLASS_DEFAULT TSRMLS_CC);
-                       if (UNEXPECTED(EG(exception) != NULL)) {
-                               HANDLE_EXCEPTION();
-                       }
-                       if (UNEXPECTED(ce == NULL)) {
-                               zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
-                       }
-                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op1.zv), ce);
-               }
-       } else {
-               ce = Z_CE_P(EX_VAR(opline->op1.var));
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_VAR_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
+}
 
-       if (IS_VAR == IS_CONST &&
-           IS_VAR == IS_CONST &&
-           CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-               fbc = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-       } else if (IS_VAR != IS_CONST &&
-                  IS_VAR == IS_CONST &&
-                  (fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce))) {
-               /* do nothing */
-       } else if (IS_VAR != IS_UNUSED) {
-               zend_free_op free_op2;
-
-               function_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-               if (IS_VAR != IS_CONST) {
-                       if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
-                               if (UNEXPECTED(EG(exception) != NULL)) {
-                                       HANDLE_EXCEPTION();
-                               }
-                               zend_error_noreturn(E_ERROR, "Function name must be a string");
-                       }
-               }
+static int ZEND_FASTCALL  ZEND_ASSIGN_SL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-               if (ce->get_static_method) {
-                       fbc = ce->get_static_method(ce, Z_STR_P(function_name) TSRMLS_CC);
-               } else {
-                       fbc = zend_std_get_static_method(ce, Z_STR_P(function_name), ((IS_VAR == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
-               }
-               if (UNEXPECTED(fbc == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name->val, Z_STRVAL_P(function_name));
-               }
-               if (IS_VAR == IS_CONST &&
-                   EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
-                   EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0)) {
-                       if (IS_VAR == IS_CONST) {
-                               CACHE_PTR(Z_CACHE_SLOT_P(function_name), fbc);
-                       } else {
-                               CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), ce, fbc);
-                       }
-               }
-               if (IS_VAR != IS_CONST) {
-                       zval_ptr_dtor_nogc(free_op2);
-               }
-       } else {
-               if (UNEXPECTED(ce->constructor == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot call constructor");
-               }
-               if (Z_OBJ(EX(This)) && Z_OBJ(EX(This))->ce != ce->constructor->common.scope && (ce->constructor->common.fn_flags & ZEND_ACC_PRIVATE)) {
-                       zend_error_noreturn(E_ERROR, "Cannot call private %s::__construct()", ce->name->val);
-               }
-               fbc = ce->constructor;
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_VAR_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
+}
 
-       object = NULL;
-       if (!(fbc->common.fn_flags & ZEND_ACC_STATIC)) {
-               if (Z_OBJ(EX(This))) {
-                       object = Z_OBJ(EX(This));
-                       GC_REFCOUNT(object)++;
-               }
-               if (!object ||
-                   !instanceof_function(object->ce, ce TSRMLS_CC)) {
-                   /* We are calling method of the other (incompatible) class,
-                      but passing $this. This is done for compatibility with php-4. */
-                       if (fbc->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
-                               zend_error(
-                                       object ? E_DEPRECATED : E_STRICT,
-                                       "Non-static method %s::%s() should not be called statically%s",
-                                       fbc->common.scope->name->val, fbc->common.function_name->val,
-                                       object ? ", assuming $this from incompatible context" : "");
-                       } else {
-                               /* An internal function assumes $this is present and won't check that. So PHP would crash by allowing the call. */
-                               zend_error_noreturn(
-                                       E_ERROR,
-                                       "Non-static method %s::%s() cannot be called statically%s",
-                                       fbc->common.scope->name->val, fbc->common.function_name->val,
-                                       object ? ", assuming $this from incompatible context" : "");
-                       }
-               }
-       }
+static int ZEND_FASTCALL  ZEND_ASSIGN_SR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       if (IS_VAR != IS_CONST) {
-               /* previous opcode is ZEND_FETCH_CLASS */
-               if ((opline-1)->extended_value == ZEND_FETCH_CLASS_PARENT || (opline-1)->extended_value == ZEND_FETCH_CLASS_SELF) {
-                       ce = EX(called_scope);
-               }
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_VAR_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
+}
 
-       EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
-               fbc, opline->extended_value, ce, object, EX(call) TSRMLS_CC);
+static int ZEND_FASTCALL  ZEND_ASSIGN_CONCAT_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       if (IS_VAR == IS_UNUSED) {
-               EX(call)->return_value = NULL;
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_VAR_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_CASE_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_OR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
-       zval *result = EX_VAR(opline->result.var);
-
-       SAVE_OPLINE();
-       fast_equal_function(result,
-                _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
-                _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
 
-       zval_ptr_dtor_nogc(free_op2);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_VAR_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
 }
 
-static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_AND_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
-       zval *expr_ptr, new_expr;
 
-       SAVE_OPLINE();
-       if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) &&
-           (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
-               expr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-               if (IS_VAR == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
-               }
-               ZVAL_MAKE_REF(expr_ptr);
-               Z_ADDREF_P(expr_ptr);
-               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
-       } else {
-               expr_ptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-               if (IS_VAR == IS_TMP_VAR) {
-                       ZVAL_COPY_VALUE(&new_expr, expr_ptr);
-                       expr_ptr = &new_expr;
-               } else if (IS_VAR == IS_CONST) {
-                       if (!Z_IMMUTABLE_P(expr_ptr)) {
-                               ZVAL_DUP(&new_expr, expr_ptr);
-                               expr_ptr = &new_expr;
-                       }
-               } else if ((IS_VAR == IS_CV || IS_VAR == IS_VAR) && Z_ISREF_P(expr_ptr)) {
-                       expr_ptr = Z_REFVAL_P(expr_ptr);
-                       if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
-                       zval_ptr_dtor_nogc(free_op1);
-               } else if (IS_VAR == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
-                       Z_ADDREF_P(expr_ptr);
-               }
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_VAR_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
+}
 
-       if (IS_VAR != IS_UNUSED) {
-               zend_free_op free_op2;
-               zval *offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-               zend_string *str;
-               zend_ulong hval;
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-add_again:
-               switch (Z_TYPE_P(offset)) {
-                       case IS_DOUBLE:
-                               hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                               goto num_index;
-                       case IS_LONG:
-                               hval = Z_LVAL_P(offset);
-num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
-                               break;
-                       case IS_STRING:
-                               str = Z_STR_P(offset);
-                               if (IS_VAR != IS_CONST) {
-                                       if (ZEND_HANDLE_NUMERIC(str, hval)) {
-                                               goto num_index;
-                                       }
-                               }
-str_index:
-                               zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
-                               break;
-                       case IS_NULL:
-                               str = STR_EMPTY_ALLOC();
-                               goto str_index;
-                       case IS_FALSE:
-                               hval = 0;
-                               goto num_index;
-                       case IS_TRUE:
-                               hval = 1;
-                               goto num_index;
-                       case IS_REFERENCE:
-                               offset = Z_REFVAL_P(offset);
-                               goto add_again;
-                               break;
-                       default:
-                               zend_error(E_WARNING, "Illegal offset type");
-                               zval_ptr_dtor(expr_ptr);
-                               /* do nothing */
-                               break;
-               }
-               zval_ptr_dtor_nogc(free_op2);
-       } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_VAR_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_VAR_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
+}
+
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1, free_op2;
+       zval *container;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+       zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
+       zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zval *array;
-       uint32_t size;
        USE_OPLINE
+       zend_free_op free_op1, free_op2;
+       zval *container;
 
-       array = EX_VAR(opline->result.var);
-       if (IS_VAR != IS_UNUSED) {
-               size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
-       } else {
-               size = 0;
-       }
-       ZVAL_NEW_ARR(array);
-       zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
 
-       if (IS_VAR != IS_UNUSED) {
-               /* Explicitly initialize array as not-packed if flag is set */
-               if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
-                       zend_hash_real_init(Z_ARRVAL_P(array), 0);
-               }
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-
-       if (IS_VAR == IS_UNUSED) {
-               ZEND_VM_NEXT_OPCODE();
-#if 0 || IS_VAR != IS_UNUSED
-       } else {
-               return ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-#endif
+       ZVAL_DEREF(container);
+       zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
+       if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
+       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval tmp, *varname;
-       HashTable *target_symbol_table;
-       zend_free_op free_op1;
+       zend_free_op free_op1, free_op2;
+       zval *container;
 
        SAVE_OPLINE();
-       if (IS_VAR == IS_CV &&
-           IS_VAR == IS_UNUSED &&
-           (opline->extended_value & ZEND_QUICK_SET)) {
-               zval *var = EX_VAR(opline->op1.var);
-
-               if (Z_REFCOUNTED_P(var)) {
-                       zend_refcounted *garbage = Z_COUNTED_P(var);
+       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
 
-                       if (!--GC_REFCOUNT(garbage)) {
-                               ZVAL_UNDEF(var);
-                               _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
-                       } else {
-                               GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
-                               ZVAL_UNDEF(var);
-                       }
-               } else {
-                       ZVAL_UNDEF(var);
-               }
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-
-       varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       ZVAL_UNDEF(&tmp);
-       if (IS_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-               ZVAL_STR(&tmp, zval_get_string(varname));
-               varname = &tmp;
+       ZVAL_DEREF(container);
+       zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
+       if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
+       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       if (IS_VAR != IS_UNUSED) {
-               zend_class_entry *ce;
-
-               if (IS_VAR == IS_CONST) {
-                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                       } else {
-                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                               if (UNEXPECTED(EG(exception) != NULL)) {
-                                       if (IS_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-                                               zend_string_release(Z_STR(tmp));
-                                       }
-                                       zval_ptr_dtor_nogc(free_op1);
-                                       HANDLE_EXCEPTION();
-                               }
-                               if (UNEXPECTED(ce == NULL)) {
-                                       zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
-                               }
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
-                       }
-               } else {
-                       ce = Z_CE_P(EX_VAR(opline->op2.var));
-               }
-               zend_std_unset_static_property(ce, Z_STR_P(varname), ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
-       } else {
-               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-               zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
-       }
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1, free_op2;
+       zval *container;
 
-       if (IS_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-               zend_string_release(Z_STR(tmp));
-       }
+       SAVE_OPLINE();
+       container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+       zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
        zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
        zval *container;
-       zval *offset;
-       zend_ulong hval;
+       zend_free_op free_op1, free_op2;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
-       }
-       if (IS_VAR != IS_UNUSED) {
-               ZVAL_DEREF(container);
-       }
-       SEPARATE_ZVAL_NOREF(container);
-       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if (IS_VAR != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
-               HashTable *ht = Z_ARRVAL_P(container);
-offset_again:
-               switch (Z_TYPE_P(offset)) {
-                       case IS_DOUBLE:
-                               hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                               zend_hash_index_del(ht, hval);
-                               break;
-                       case IS_LONG:
-                               hval = Z_LVAL_P(offset);
-num_index_dim:
-                               zend_hash_index_del(ht, hval);
-                               break;
-                       case IS_STRING:
-                               if (IS_VAR != IS_CONST) {
-                                       if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
-                                               goto num_index_dim;
-                                       }
-                               }
-                               if (ht == &EG(symbol_table).ht) {
-                                       zend_delete_global_variable(Z_STR_P(offset) TSRMLS_CC);
-                               } else {
-                                       zend_hash_del(ht, Z_STR_P(offset));
-                               }
-                               break;
-                       case IS_NULL:
-                               zend_hash_del(ht, STR_EMPTY_ALLOC());
-                               break;
-                       case IS_FALSE:
-                               hval = 0;
-                               goto num_index_dim;
-                       case IS_TRUE:
-                               hval = 1;
-                               goto num_index_dim;
-                       case IS_RESOURCE:
-                               hval = Z_RES_HANDLE_P(offset);
-                               goto num_index_dim;
-                       case IS_REFERENCE:
-                               offset = Z_REFVAL_P(offset);
-                               goto offset_again;
-                               break;
-                       default:
-                               zend_error(E_WARNING, "Illegal offset type in unset");
-                               break;
+       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+        if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
+            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+        }
+               container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               zval_ptr_dtor_nogc(free_op2);
-       } else if (IS_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use object as array");
+               ZVAL_DEREF(container);
+               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+               if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
+                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
                }
-//???          if (IS_VAR == IS_CONST) {
-//???                  zval_copy_ctor(offset);
-//???          }
-               Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
                zval_ptr_dtor_nogc(free_op2);
-       } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
-               ZEND_VM_CONTINUE(); /* bailed out before */
+               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        } else {
+               if (IS_VAR == IS_UNUSED) {
+                       zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
+               }
+               container = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
                zval_ptr_dtor_nogc(free_op2);
+               zval_ptr_dtor_nogc(free_op1);
        }
-       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_UNSET_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *container;
-       zval *offset;
 
        SAVE_OPLINE();
        container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
-       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
-       }
-       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if (IS_VAR != IS_UNUSED) {
-               ZVAL_DEREF(container);
-       }
-       if (IS_VAR == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
-               if (Z_OBJ_HT_P(container)->unset_property) {
-                       Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
-               } else {
-                       zend_error(E_NOTICE, "Trying to unset property of non-object");
-               }
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
+       ZVAL_DEREF(container);
+       zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op2);
+       if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+       }
        if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *value;
+       zend_free_op free_op1;
+       zval *object_ptr;
 
        SAVE_OPLINE();
-       if (IS_VAR == IS_CV &&
-           IS_VAR == IS_UNUSED &&
-           (opline->extended_value & ZEND_QUICK_SET)) {
-               value = EX_VAR(opline->op1.var);
-               if (opline->extended_value & ZEND_ISSET) {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               !i_zend_is_true(value TSRMLS_CC));
-                       CHECK_EXCEPTION();
-               }
-               ZEND_VM_NEXT_OPCODE();
-       } else {
-               zend_free_op free_op1;
-               zval tmp, *varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+       object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
 
-               ZVAL_UNDEF(&tmp);
-               if (IS_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-                       ZVAL_STR(&tmp, zval_get_string(varname));
-                       varname = &tmp;
-               }
+       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+       }
+       ZVAL_DEREF(object_ptr);
+       if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
+               zend_free_op free_op2;
+               zval *property_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-               if (IS_VAR != IS_UNUSED) {
-                       zend_class_entry *ce;
+               zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_VAR, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+               zval_ptr_dtor_nogc(free_op2);
+       } else {
+               zend_free_op free_op2, free_op_data1;
+               zval  rv;
+               zval *value;
+               zval *dim = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+               zval *variable_ptr;
 
-                       if (IS_VAR == IS_CONST) {
-                               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                                       ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                               } else {
-                                       ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                                       if (UNEXPECTED(ce == NULL)) {
-                                               CHECK_EXCEPTION();
-                                               ZEND_VM_NEXT_OPCODE();
-                                       }
-                                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+               if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
+                   EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
+                       zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
+                       zval_ptr_dtor_nogc(free_op2);
+                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+                       zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
+                       FREE_OP(free_op_data1);
+               } else {
+                       zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_VAR TSRMLS_CC);
+                       zval_ptr_dtor_nogc(free_op2);
+                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+                       ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+                       variable_ptr = Z_INDIRECT(rv);
+                       if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
+                               FREE_OP(free_op_data1);
+                               if (RETURN_VALUE_USED(opline)) {
+                                       ZVAL_NULL(EX_VAR(opline->result.var));
                                }
                        } else {
-                               ce = Z_CE_P(EX_VAR(opline->op2.var));
+                               value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
+                               if ((opline+1)->op1_type == IS_VAR) {
+                                       FREE_OP(free_op_data1);
+                               }
+                               if (RETURN_VALUE_USED(opline)) {
+                                       ZVAL_COPY(EX_VAR(opline->result.var), value);
+                               }
                        }
-                       value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
-               } else {
-                       HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-                       value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
-               }
-
-               if (IS_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-                       zend_string_release(Z_STR(tmp));
-               }
-               zval_ptr_dtor_nogc(free_op1);
-
-               if (opline->extended_value & ZEND_ISSET) {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               value && Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               !value || !i_zend_is_true(value TSRMLS_CC));
                }
-
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
        }
+       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+       /* assign_dim has two opcodes! */
+       CHECK_EXCEPTION();
+       ZEND_VM_INC_OPCODE();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *container;
-       int result;
-       zend_ulong hval;
-       zval *offset;
+       zval *value;
+       zval *variable_ptr;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
-       if (IS_VAR != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
-               HashTable *ht = Z_ARRVAL_P(container);
-               zval *value;
-               zend_string *str;
-
-isset_again:
-               if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
-                       str = Z_STR_P(offset);
-                       if (IS_VAR != IS_CONST) {
-                               if (ZEND_HANDLE_NUMERIC(str, hval)) {
-                                       goto num_index_prop;
-                               }
-                       }
-str_index_prop:
-                       value = zend_hash_find_ind(ht, str);
-               } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
-                       hval = Z_LVAL_P(offset);
-num_index_prop:
-                       value = zend_hash_index_find(ht, hval);
-               } else {
-                       switch (Z_TYPE_P(offset)) {
-                               case IS_DOUBLE:
-                                       hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                                       goto num_index_prop;
-                               case IS_NULL:
-                                       str = STR_EMPTY_ALLOC();
-                                       goto str_index_prop;
-                               case IS_FALSE:
-                                       hval = 0;
-                                       goto num_index_prop;
-                               case IS_TRUE:
-                                       hval = 1;
-                                       goto num_index_prop;
-                               case IS_RESOURCE:
-                                       hval = Z_RES_HANDLE_P(offset);
-                                       goto num_index_prop;
-                               case IS_REFERENCE:
-                                       offset = Z_REFVAL_P(offset);
-                                       goto isset_again;
-                               default:
-                                       zend_error(E_WARNING, "Illegal offset type in isset or empty");
-                                       value = NULL;
-                                       break;
-                       }
-               }
-
-               if (opline->extended_value & ZEND_ISSET) {
-                       /* > IS_NULL means not IS_UNDEF and not IS_NULL */
-                       result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
-               }
-       } else if (IS_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
-                       result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
-               } else {
-                       zend_error(E_NOTICE, "Trying to check element of non-array");
-                       result = 0;
-               }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
-               }
-       } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
-               zval tmp;
+       value = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+       variable_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
 
-               result = 0;
-               if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
-                       if (IS_VAR == IS_CV || IS_VAR == IS_VAR) {
-                               ZVAL_DEREF(offset);
-                       }
-                       if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
-                                       || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
-                                               && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
-                               ZVAL_DUP(&tmp, offset);
-                               convert_to_long(&tmp);
-                               offset = &tmp;
-                       }
-               }
-               if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
-                       if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
-                               if ((opline->extended_value & ZEND_ISSET) ||
-                                   Z_STRVAL_P(container)[offset->value.lval] != '0') {
-                                       result = 1;
-                               }
-                       }
+       if (IS_VAR == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
+               if (IS_VAR == IS_TMP_VAR) {
+                       zval_ptr_dtor_nogc(free_op2);
                }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
                }
        } else {
-               result = ((opline->extended_value & ZEND_ISSET) == 0);
+               value = zend_assign_to_variable(variable_ptr, value, IS_VAR TSRMLS_CC);
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_COPY(EX_VAR(opline->result.var), value);
+               }
+               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        }
 
-       zval_ptr_dtor_nogc(free_op2);
-       ZVAL_BOOL(EX_VAR(opline->result.var), result);
-       zval_ptr_dtor_nogc(free_op1);
+       /* zend_assign_to_variable() always takes care of op2, never free it! */
+       zval_ptr_dtor_nogc(free_op2);
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_REF_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *container;
-       int result;
-       zval *offset;
+       zval *variable_ptr;
+       zval *value_ptr;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
-       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+       value_ptr = _get_zval_ptr_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if (IS_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
-                       result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
-               } else {
-                       zend_error(E_NOTICE, "Trying to check property of non-object");
-                       result = 0;
+       if (IS_VAR == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
+       }
+       if (IS_VAR == IS_VAR &&
+           (value_ptr == &EG(uninitialized_zval) ||
+            (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+             !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+               if (!(free_op2 != NULL)) {
+                       PZVAL_LOCK(value_ptr); /* undo the effect of get_zval_ptr_ptr() */
                }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
+               zend_error(E_STRICT, "Only variables should be assigned by reference");
+               if (UNEXPECTED(EG(exception) != NULL)) {
+                       if (free_op2) {zval_ptr_dtor_nogc(free_op2);};
+                       HANDLE_EXCEPTION();
+               }
+               return ZEND_ASSIGN_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (IS_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
+               if (!(free_op2 != NULL)) {
+                       PZVAL_LOCK(value_ptr);
                }
+       }
+
+       variable_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+       if (IS_VAR == IS_VAR && UNEXPECTED(variable_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
+       }
+       if (IS_VAR == IS_VAR &&
+           UNEXPECTED(Z_TYPE_P(EX_VAR(opline->op1.var)) != IS_INDIRECT) &&
+           UNEXPECTED(!Z_ISREF_P(variable_ptr))) {
+               zend_error_noreturn(E_ERROR, "Cannot assign by reference to overloaded object");
+       }
+       if ((IS_VAR == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) ||
+           (IS_VAR == IS_VAR && UNEXPECTED(value_ptr == &EG(error_zval)))) {
+               variable_ptr = &EG(uninitialized_zval);
        } else {
-               result = ((opline->extended_value & ZEND_ISSET) == 0);
+               zend_assign_to_variable_reference(variable_ptr, value_ptr TSRMLS_CC);
        }
 
-       zval_ptr_dtor_nogc(free_op2);
-       ZVAL_BOOL(EX_VAR(opline->result.var), result);
-       zval_ptr_dtor_nogc(free_op1);
+       if (IS_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
+               if (!(free_op2 != NULL)) {
+                       Z_DELREF_P(variable_ptr);
+               }
+       }
+
+       if (RETURN_VALUE_USED(opline)) {
+               ZVAL_COPY(EX_VAR(opline->result.var), variable_ptr);
+       }
+
+       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+       if (free_op2) {zval_ptr_dtor_nogc(free_op2);};
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
@@ -23909,154 +18870,6 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE
        }
 }
 
-static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_VAR_UNUSED(int type, ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *varname;
-       zval *retval;
-       zend_string *name;
-       HashTable *target_symbol_table;
-
-       SAVE_OPLINE();
-       varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       if (IS_VAR == IS_CONST) {
-               name = Z_STR_P(varname);
-       } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
-               name = Z_STR_P(varname);
-               zend_string_addref(name);
-       } else {
-               name = zval_get_string(varname);
-       }
-
-       if (IS_UNUSED != IS_UNUSED) {
-               zend_class_entry *ce;
-
-               if (IS_UNUSED == IS_CONST) {
-                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                       } else {
-                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                               if (UNEXPECTED(ce == NULL)) {
-                                       if (IS_VAR != IS_CONST) {
-                                               zend_string_release(name);
-                                       }
-                                       zval_ptr_dtor_nogc(free_op1);
-                                       CHECK_EXCEPTION();
-                                       ZEND_VM_NEXT_OPCODE();
-                               }
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
-                       }
-               } else {
-                       ce = Z_CE_P(EX_VAR(opline->op2.var));
-               }
-               retval = zend_std_get_static_property(ce, name, 0, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op1);
-       } else {
-               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-               retval = zend_hash_find(target_symbol_table, name);
-               if (retval == NULL) {
-                       switch (type) {
-                               case BP_VAR_R:
-                               case BP_VAR_UNSET:
-                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                       /* break missing intentionally */
-                               case BP_VAR_IS:
-                                       retval = &EG(uninitialized_zval);
-                                       break;
-                               case BP_VAR_RW:
-                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                       /* break missing intentionally */
-                               case BP_VAR_W:
-                                       retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
-                                       break;
-                               EMPTY_SWITCH_DEFAULT_CASE()
-                       }
-               /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
-               } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
-                       retval = Z_INDIRECT_P(retval);
-                       if (Z_TYPE_P(retval) == IS_UNDEF) {
-                               switch (type) {
-                                       case BP_VAR_R:
-                                       case BP_VAR_UNSET:
-                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                               /* break missing intentionally */
-                                       case BP_VAR_IS:
-                                               retval = &EG(uninitialized_zval);
-                                               break;
-                                       case BP_VAR_RW:
-                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                               /* break missing intentionally */
-                                       case BP_VAR_W:
-                                               ZVAL_NULL(retval);
-                                               break;
-                                       EMPTY_SWITCH_DEFAULT_CASE()
-                               }
-                       }
-               }
-               if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
-                       if (Z_CONSTANT_P(retval)) {
-                               zval_update_constant(retval, 1 TSRMLS_CC);
-                       }
-               } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
-                       zval_ptr_dtor_nogc(free_op1);
-               }
-       }
-
-       if (IS_VAR != IS_CONST) {
-               zend_string_release(name);
-       }
-
-       ZEND_ASSERT(retval != NULL);
-       if (type == BP_VAR_R || type == BP_VAR_IS) {
-               if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
-                       ZVAL_UNREF(retval);
-               }
-               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-       } else {
-               ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
-       }
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_R_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_VAR_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_W_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_VAR_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_RW_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_VAR_UNUSED(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_FUNC_ARG_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-               return zend_fetch_var_address_helper_SPEC_VAR_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else {
-               return zend_fetch_var_address_helper_SPEC_VAR_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_UNSET_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_VAR_UNUSED(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_IS_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_VAR_UNUSED(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
@@ -24444,153 +19257,6 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HA
        }
 }
 
-static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval tmp, *varname;
-       HashTable *target_symbol_table;
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-       if (IS_VAR == IS_CV &&
-           IS_UNUSED == IS_UNUSED &&
-           (opline->extended_value & ZEND_QUICK_SET)) {
-               zval *var = EX_VAR(opline->op1.var);
-
-               if (Z_REFCOUNTED_P(var)) {
-                       zend_refcounted *garbage = Z_COUNTED_P(var);
-
-                       if (!--GC_REFCOUNT(garbage)) {
-                               ZVAL_UNDEF(var);
-                               _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
-                       } else {
-                               GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
-                               ZVAL_UNDEF(var);
-                       }
-               } else {
-                       ZVAL_UNDEF(var);
-               }
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
-
-       varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-       ZVAL_UNDEF(&tmp);
-       if (IS_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-               ZVAL_STR(&tmp, zval_get_string(varname));
-               varname = &tmp;
-       }
-
-       if (IS_UNUSED != IS_UNUSED) {
-               zend_class_entry *ce;
-
-               if (IS_UNUSED == IS_CONST) {
-                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                       } else {
-                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                               if (UNEXPECTED(EG(exception) != NULL)) {
-                                       if (IS_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-                                               zend_string_release(Z_STR(tmp));
-                                       }
-                                       zval_ptr_dtor_nogc(free_op1);
-                                       HANDLE_EXCEPTION();
-                               }
-                               if (UNEXPECTED(ce == NULL)) {
-                                       zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
-                               }
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
-                       }
-               } else {
-                       ce = Z_CE_P(EX_VAR(opline->op2.var));
-               }
-               zend_std_unset_static_property(ce, Z_STR_P(varname), ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
-       } else {
-               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-               zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
-       }
-
-       if (IS_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-               zend_string_release(Z_STR(tmp));
-       }
-       zval_ptr_dtor_nogc(free_op1);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *value;
-
-       SAVE_OPLINE();
-       if (IS_VAR == IS_CV &&
-           IS_UNUSED == IS_UNUSED &&
-           (opline->extended_value & ZEND_QUICK_SET)) {
-               value = EX_VAR(opline->op1.var);
-               if (opline->extended_value & ZEND_ISSET) {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               !i_zend_is_true(value TSRMLS_CC));
-                       CHECK_EXCEPTION();
-               }
-               ZEND_VM_NEXT_OPCODE();
-       } else {
-               zend_free_op free_op1;
-               zval tmp, *varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
-
-               ZVAL_UNDEF(&tmp);
-               if (IS_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-                       ZVAL_STR(&tmp, zval_get_string(varname));
-                       varname = &tmp;
-               }
-
-               if (IS_UNUSED != IS_UNUSED) {
-                       zend_class_entry *ce;
-
-                       if (IS_UNUSED == IS_CONST) {
-                               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                                       ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                               } else {
-                                       ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                                       if (UNEXPECTED(ce == NULL)) {
-                                               CHECK_EXCEPTION();
-                                               ZEND_VM_NEXT_OPCODE();
-                                       }
-                                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
-                               }
-                       } else {
-                               ce = Z_CE_P(EX_VAR(opline->op2.var));
-                       }
-                       value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
-               } else {
-                       HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-                       value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
-               }
-
-               if (IS_VAR != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-                       zend_string_release(Z_STR(tmp));
-               }
-               zval_ptr_dtor_nogc(free_op1);
-
-               if (opline->extended_value & ZEND_ISSET) {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               value && Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               !value || !i_zend_is_true(value TSRMLS_CC));
-               }
-
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
-}
-
 static int ZEND_FASTCALL  ZEND_SEPARATE_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
@@ -26157,21 +20823,6 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_CV_HANDLER(ZEND_
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_CASE_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *result = EX_VAR(opline->result.var);
-
-       SAVE_OPLINE();
-       fast_equal_function(result,
-                _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
-                _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
 static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
@@ -26487,7 +21138,7 @@ num_index_prop:
 
                result = 0;
                if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
-                       if (IS_CV == IS_CV || IS_CV == IS_VAR) {
+                       if (IS_CV & (IS_CV|IS_VAR)) {
                                ZVAL_DEREF(offset);
                        }
                        if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
@@ -26703,440 +21354,35 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_POW_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLE
        return zend_binary_assign_op_helper_SPEC_VAR_CV(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_CLONE_SPEC_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       zval *obj;
-       zend_class_entry *ce;
-       zend_function *clone;
-       zend_object_clone_obj_t clone_call;
-
-       SAVE_OPLINE();
-       obj = _get_obj_zval_ptr_unused(execute_data);
-
-       if (IS_UNUSED == IS_CONST ||
-           (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(obj) != IS_OBJECT))) {
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       HANDLE_EXCEPTION();
-               }
-               zend_error_noreturn(E_ERROR, "__clone method called on non-object");
-       }
-
-       ce = Z_OBJCE_P(obj);
-       clone = ce ? ce->clone : NULL;
-       clone_call =  Z_OBJ_HT_P(obj)->clone_obj;
-       if (UNEXPECTED(clone_call == NULL)) {
-               if (ce) {
-                       zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object of class %s", ce->name->val);
-               } else {
-                       zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object");
-               }
-       }
-
-       if (ce && clone) {
-               if (clone->op_array.fn_flags & ZEND_ACC_PRIVATE) {
-                       /* Ensure that if we're calling a private function, we're allowed to do so.
-                        */
-                       if (UNEXPECTED(ce != EG(scope))) {
-                               zend_error_noreturn(E_ERROR, "Call to private %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
-                       }
-               } else if ((clone->common.fn_flags & ZEND_ACC_PROTECTED)) {
-                       /* Ensure that if we're calling a protected function, we're allowed to do so.
-                        */
-                       if (UNEXPECTED(!zend_check_protected(zend_get_function_root_class(clone), EG(scope)))) {
-                               zend_error_noreturn(E_ERROR, "Call to protected %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
-                       }
-               }
-       }
-
-       if (EXPECTED(EG(exception) == NULL)) {
-               ZVAL_OBJ(EX_VAR(opline->result.var), clone_call(obj TSRMLS_CC));
-               if (!RETURN_VALUE_USED(opline) || UNEXPECTED(EG(exception) != NULL)) {
-                       OBJ_RELEASE(Z_OBJ_P(EX_VAR(opline->result.var)));
-               }
-       }
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_EXIT_SPEC_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-#if 0 || (IS_UNUSED != IS_UNUSED)
-       USE_OPLINE
-
-       SAVE_OPLINE();
-       if (IS_UNUSED != IS_UNUSED) {
-
-               zval *ptr = NULL;
-
-               if (Z_TYPE_P(ptr) == IS_LONG) {
-                       EG(exit_status) = Z_LVAL_P(ptr);
-               } else {
-                       zend_print_variable(ptr TSRMLS_CC);
-               }
-
-       }
-#endif
-       zend_bailout();
-       ZEND_VM_NEXT_OPCODE(); /* Never reached */
-}
-
-static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_TMPVAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op_data1;
-       zval *object = _get_obj_zval_ptr_unused(execute_data);
-       zval *property = opline->op2.zv;
-       zval *value;
-       zval *zptr;
-
-       if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
-       }
-
-       if (IS_UNUSED != IS_UNUSED) {
-               object = make_real_object(object TSRMLS_CC);
-       }
-
-       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-
-       if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
-               zend_error(E_WARNING, "Attempt to assign property of non-object");
-
-               FREE_OP(free_op_data1);
-
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
-               }
-       } else {
-               /* here we are sure we are dealing with an object */
-               if (opline->extended_value == ZEND_ASSIGN_OBJ
-                       && EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-                       && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
-
-                       ZVAL_DEREF(zptr);
-                       SEPARATE_ZVAL_NOREF(zptr);
-
-                       binary_op(zptr, zptr, value TSRMLS_CC);
-                       if (RETURN_VALUE_USED(opline)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), zptr);
-                       }
-               } else {
-                       zval *z = NULL;
-                       zval rv;
-
-                       if (opline->extended_value == ZEND_ASSIGN_OBJ) {
-                               if (Z_OBJ_HT_P(object)->read_property) {
-                                       z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
-                               }
-                       } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
-                               if (Z_OBJ_HT_P(object)->read_dimension) {
-                                       z = Z_OBJ_HT_P(object)->read_dimension(object, property, BP_VAR_R, &rv TSRMLS_CC);
-                               }
-                       }
-                       if (z) {
-                               if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
-                                       zval rv;
-                                       zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
-
-                                       if (Z_REFCOUNT_P(z) == 0) {
-                                               zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
-                                       }
-                                       ZVAL_COPY_VALUE(z, value);
-                               }
-//???                          if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
-                               SEPARATE_ZVAL_IF_NOT_REF(z);
-                               binary_op(z, z, value TSRMLS_CC);
-                               if (opline->extended_value == ZEND_ASSIGN_OBJ) {
-                                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
-                               } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
-                                       Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
-                               }
-                               if (RETURN_VALUE_USED(opline)) {
-                                       ZVAL_COPY(EX_VAR(opline->result.var), z);
-                               }
-                               zval_ptr_dtor(z);
-                       } else {
-                               zend_error(E_WARNING, "Attempt to assign property of non-object");
-                               if (RETURN_VALUE_USED(opline)) {
-                                       ZVAL_NULL(EX_VAR(opline->result.var));
-                               }
-                       }
-               }
-
-               FREE_OP(free_op_data1);
-       }
-
-       /* assign_obj has two opcodes! */
-       CHECK_EXCEPTION();
-       ZEND_VM_INC_OPCODE();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op_data1;
-       zval *var_ptr, rv;
-       zval *value, *container;
-
-       SAVE_OPLINE();
-       container = _get_obj_zval_ptr_unused(execute_data);
-       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-       }
-       if (IS_UNUSED != IS_UNUSED) {
-               ZVAL_DEREF(container);
-       }
-       if (IS_UNUSED == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (IS_UNUSED == IS_VAR && !0) {
-                       Z_ADDREF_P(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
-               }
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else {
-               zval *dim = opline->op2.zv;
-
-               zend_fetch_dimension_address_RW(&rv, container, dim, IS_CONST TSRMLS_CC);
-               value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-               ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
-               var_ptr = Z_INDIRECT(rv);
-       }
-
-       if (UNEXPECTED(var_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
-       }
-
-       if (UNEXPECTED(var_ptr == &EG(error_zval))) {
-               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
-               }
-       } else {
-               ZVAL_DEREF(var_ptr);
-               SEPARATE_ZVAL_NOREF(var_ptr);
-
-               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
-
-               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
-               }
-       }
-
-       FREE_OP(free_op_data1);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_INC_OPCODE();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       zval *var_ptr;
-       zval *value;
-
-       SAVE_OPLINE();
-       value = opline->op2.zv;
-       var_ptr = NULL;
-
-       if (IS_UNUSED == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
-       }
-
-       if (IS_UNUSED == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
-               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
-               }
-       } else {
-               ZVAL_DEREF(var_ptr);
-               SEPARATE_ZVAL_NOREF(var_ptr);
-
-               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
-
-               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
-               }
-       }
-
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_ADD_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_SUB_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_MUL_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_DIV_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_MOD_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_SL_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_SR_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_CONCAT_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_OR_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_AND_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
+       zend_free_op free_op1, free_op2;
        zval *object;
        zval *property;
        zval *retval;
        zval *zptr;
 
        SAVE_OPLINE();
-       object = _get_obj_zval_ptr_unused(execute_data);
-       property = opline->op2.zv;
+       object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
        retval = EX_VAR(opline->result.var);
 
-       if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
-       if (IS_UNUSED != IS_UNUSED) {
+       if (IS_VAR != IS_UNUSED) {
                object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
        }
 
-       if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+       if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-
+               zval_ptr_dtor_nogc(free_op2);
                if (RETURN_VALUE_USED(opline)) {
                        ZVAL_NULL(retval);
                }
-
+               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
                CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
@@ -27144,7 +21390,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_CONST(incde
        /* here we are sure we are dealing with an object */
 
        if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
 
                ZVAL_DEREF(zptr);
                SEPARATE_ZVAL_NOREF(zptr);
@@ -27157,7 +21403,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_CONST(incde
                zval rv;
 
                if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
-                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
 
                        if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval rv;
@@ -27172,7 +21418,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_CONST(incde
                        SEPARATE_ZVAL_IF_NOT_REF(z);
                        incdec_op(z);
                        ZVAL_COPY_VALUE(retval, z);
-                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+                       Z_OBJ_HT_P(object)->write_property(object, property, z, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
                        SELECTIVE_PZVAL_LOCK(retval, opline);
                        zval_ptr_dtor(z);
                } else {
@@ -27183,48 +21429,49 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_CONST(incde
                }
        }
 
-
+       zval_ptr_dtor_nogc(free_op2);
+       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_PRE_INC_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_PRE_INC_OBJ_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_pre_incdec_property_helper_SPEC_UNUSED_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_pre_incdec_property_helper_SPEC_VAR_TMPVAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_pre_incdec_property_helper_SPEC_UNUSED_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_pre_incdec_property_helper_SPEC_VAR_TMPVAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_TMPVAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
+       zend_free_op free_op1, free_op2;
        zval *object;
        zval *property;
        zval *retval;
        zval *zptr;
 
        SAVE_OPLINE();
-       object = _get_obj_zval_ptr_unused(execute_data);
-       property = opline->op2.zv;
+       object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
        retval = EX_VAR(opline->result.var);
 
-       if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
-       if (IS_UNUSED != IS_UNUSED) {
+       if (IS_VAR != IS_UNUSED) {
                object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
        }
 
-       if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+       if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-
+               zval_ptr_dtor_nogc(free_op2);
                ZVAL_NULL(retval);
-
+               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
                CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
@@ -27232,7 +21479,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_CONST(incd
        /* here we are sure we are dealing with an object */
 
        if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
 
                ZVAL_DEREF(zptr);
                ZVAL_COPY_VALUE(retval, zptr);
@@ -27242,7 +21489,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_CONST(incd
        } else {
                if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
                        zval rv;
-                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
                        zval z_copy;
 
                        if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
@@ -27258,7 +21505,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_CONST(incd
                        ZVAL_DUP(&z_copy, z);
                        incdec_op(&z_copy);
                        if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
-                       Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+                       Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
                        zval_ptr_dtor(&z_copy);
                        zval_ptr_dtor(z);
                } else {
@@ -27267,34 +21514,35 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_CONST(incd
                }
        }
 
-
+       zval_ptr_dtor_nogc(free_op2);
+       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_POST_INC_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_POST_INC_OBJ_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_post_incdec_property_helper_SPEC_UNUSED_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_post_incdec_property_helper_SPEC_VAR_TMPVAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_post_incdec_property_helper_SPEC_UNUSED_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_post_incdec_property_helper_SPEC_VAR_TMPVAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
+       zend_free_op free_op1;
        zval *container;
-
+       zend_free_op free_op2;
        zval *offset;
 
        SAVE_OPLINE();
-       container = _get_obj_zval_ptr_unused(execute_data);
-       offset  = opline->op2.zv;
+       container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
+       offset  = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if ((IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+       if ((IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
            UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
                zend_error(E_NOTICE, "Trying to get property of non-object");
                ZVAL_NULL(EX_VAR(opline->result.var));
@@ -27303,7 +21551,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE
 
                /* here we are sure we are dealing with an object */
                do {
-                       if (IS_CONST == IS_CONST &&
+                       if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
                                EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
                                zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
                                zend_object *zobj = Z_OBJ_P(container);
@@ -27323,7 +21571,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE
                                }
                        }
 
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
 
                        if (retval != EX_VAR(opline->result.var)) {
                                ZVAL_COPY(EX_VAR(opline->result.var), retval);
@@ -27331,73 +21579,74 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE
                } while (0);
        }
 
-
+       zval_ptr_dtor_nogc(free_op2);
+       zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
+       zend_free_op free_op1, free_op2;
        zval *property;
        zval *container;
 
        SAVE_OPLINE();
-       property = opline->op2.zv;
+       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       container = _get_obj_zval_ptr_unused(execute_data);
-       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
 
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
-
-       if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
+       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
+       if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
                EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
-
+       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
+       zend_free_op free_op1, free_op2;
        zval *property;
        zval *container;
 
        SAVE_OPLINE();
-       property = opline->op2.zv;
-       container = _get_obj_zval_ptr_unused(execute_data);
+       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
 
-       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
-
-       if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
+       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
+       if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
                EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
-
+       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
+       zend_free_op free_op1;
        zval *container;
-
+       zend_free_op free_op2;
        zval *offset;
 
        SAVE_OPLINE();
-       container = _get_obj_zval_ptr_unused(execute_data);
-       offset  = opline->op2.zv;
+       container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
+       offset  = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if ((IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+       if ((IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
            UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
                ZVAL_NULL(EX_VAR(opline->result.var));
        } else {
@@ -27405,7 +21654,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCOD
 
                /* here we are sure we are dealing with an object */
                do {
-                       if (IS_CONST == IS_CONST &&
+                       if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
                                EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
                                zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
                                zend_object *zobj = Z_OBJ_P(container);
@@ -27425,7 +21674,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCOD
                                }
                        }
 
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
 
                        if (retval != EX_VAR(opline->result.var)) {
                                ZVAL_COPY(EX_VAR(opline->result.var), retval);
@@ -27433,133 +21682,96 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCOD
                } while (0);
        }
 
-
+       zval_ptr_dtor_nogc(free_op2);
+       zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zval *container;
 
        if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
                /* Behave like FETCH_OBJ_W */
-               zend_free_op free_op1;
+               zend_free_op free_op1, free_op2;
                zval *property;
 
                SAVE_OPLINE();
-               property = opline->op2.zv;
-               container = _get_obj_zval_ptr_unused(execute_data);
+               property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+               container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
 
-        if (IS_UNUSED == IS_CONST || IS_UNUSED == IS_TMP_VAR) {
+        if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
             zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
         }
-               if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
                }
-               zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
-
-               if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+               zval_ptr_dtor_nogc(free_op2);
+               if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
                        EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
                }
-
+               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
                CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
-               return ZEND_FETCH_OBJ_R_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return ZEND_FETCH_OBJ_R_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
+       zend_free_op free_op1, free_op2;
        zval *container, *property;
 
        SAVE_OPLINE();
-       container = _get_obj_zval_ptr_unused(execute_data);
-       property = opline->op2.zv;
+       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
-
-       if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
+       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_VAR, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
+       if (IS_VAR == IS_VAR && READY_TO_DESTROY(free_op1)) {
                EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
-
+       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
+       zend_free_op free_op1, free_op2;
        zval *object;
        zval *property_name;
 
        SAVE_OPLINE();
-       object = _get_obj_zval_ptr_unused(execute_data);
-       property_name = opline->op2.zv;
+       object = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+       property_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(object == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_UNUSED, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
-
-
+       zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_VAR, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
+       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        /* assign_obj has two opcodes! */
        CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ADD_CHAR_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *str = EX_VAR(opline->result.var);
-
-       SAVE_OPLINE();
-
-       if (IS_UNUSED == IS_UNUSED) {
-               /* Initialize for erealloc in add_char_to_string */
-               ZVAL_EMPTY_STRING(str);
-       }
-
-       add_char_to_string(str, str, opline->op2.zv);
-
-       /* FREE_OP is missing intentionally here - we're always working on the same temporary variable */
-       /*CHECK_EXCEPTION();*/
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_ADD_STRING_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *str = EX_VAR(opline->result.var);
-
-       SAVE_OPLINE();
-
-       if (IS_UNUSED == IS_UNUSED) {
-               /* Initialize for erealloc in add_string_to_string */
-               ZVAL_EMPTY_STRING(str);
-       }
-
-       add_string_to_string(str, str, opline->op2.zv);
-
-       /* FREE_OP is missing intentionally here - we're always working on the same temporary variable */
-       /*CHECK_EXCEPTION();*/
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zval *function_name;
-
+       zend_free_op free_op1, free_op2;
        zval *object;
        zend_function *fbc;
        zend_class_entry *called_scope;
@@ -27567,9 +21779,9 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_CONST_HANDLER(ZEND_O
 
        SAVE_OPLINE();
 
-       function_name = opline->op2.zv;
+       function_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if (IS_CONST != IS_CONST &&
+       if ((IS_TMP_VAR|IS_VAR) != IS_CONST &&
            UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                if (UNEXPECTED(EG(exception) != NULL)) {
                        HANDLE_EXCEPTION();
@@ -27577,18 +21789,19 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_CONST_HANDLER(ZEND_O
                zend_error_noreturn(E_ERROR, "Method name must be a string");
        }
 
-       object = _get_obj_zval_ptr_unused(execute_data);
+       object = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
 
-       if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+       if (IS_VAR != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                uint32_t nesting = 1;
 
                if (UNEXPECTED(EG(exception) != NULL)) {
-
+                       zval_ptr_dtor_nogc(free_op2);
                        HANDLE_EXCEPTION();
                }
 
                zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s",  Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
-
+               zval_ptr_dtor_nogc(free_op2);
+               zval_ptr_dtor_nogc(free_op1);
 
                if (EG(exception) != NULL) {
                        HANDLE_EXCEPTION();
@@ -27626,7 +21839,7 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_CONST_HANDLER(ZEND_O
        obj = Z_OBJ_P(object);
        called_scope = obj->ce;
 
-       if (IS_CONST != IS_CONST ||
+       if ((IS_TMP_VAR|IS_VAR) != IS_CONST ||
            EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
            zend_object *orig_obj = obj;
 
@@ -27635,11 +21848,11 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_CONST_HANDLER(ZEND_O
                }
 
                /* First, locate the function. */
-               fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_CONST == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
+               fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
                if (UNEXPECTED(fbc == NULL)) {
                        zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
                }
-               if (IS_CONST == IS_CONST &&
+               if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
                    EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
                    EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
                    EXPECTED(obj == orig_obj)) {
@@ -27656,117 +21869,233 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_CONST_HANDLER(ZEND_O
        EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
                fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
 
+       zval_ptr_dtor_nogc(free_op2);
+       zval_ptr_dtor_nogc(free_op1);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_CONSTANT_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zval *function_name;
+       zend_class_entry *ce;
+       zend_object *object;
+       zend_function *fbc;
 
        SAVE_OPLINE();
-       if (IS_UNUSED == IS_UNUSED) {
-               zend_constant *c;
-               zval *retval;
 
-               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                       c = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-               } else if ((c = zend_quick_get_constant(opline->op2.zv + 1, opline->extended_value TSRMLS_CC)) == NULL) {
-                       if ((opline->extended_value & IS_CONSTANT_UNQUALIFIED) != 0) {
-                               char *actual = (char *)zend_memrchr(Z_STRVAL_P(opline->op2.zv), '\\', Z_STRLEN_P(opline->op2.zv));
-                               if (!actual) {
-                                       ZVAL_STR(EX_VAR(opline->result.var), zend_string_copy(Z_STR_P(opline->op2.zv)));
-                               } else {
-                                       actual++;
-                                       ZVAL_STRINGL(EX_VAR(opline->result.var),
-                                                       actual, Z_STRLEN_P(opline->op2.zv) - (actual - Z_STRVAL_P(opline->op2.zv)));
-                               }
-                               /* non-qualified constant - allow text substitution */
-                               zend_error(E_NOTICE, "Use of undefined constant %s - assumed '%s'",
-                                               Z_STRVAL_P(EX_VAR(opline->result.var)), Z_STRVAL_P(EX_VAR(opline->result.var)));
-                               CHECK_EXCEPTION();
-                               ZEND_VM_NEXT_OPCODE();
-                       } else {
-                               zend_error_noreturn(E_ERROR, "Undefined constant '%s'", Z_STRVAL_P(opline->op2.zv));
-                       }
+       if (IS_VAR == IS_CONST) {
+               /* no function found. try a static method in class */
+               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv))) {
+                       ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv));
                } else {
-                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), c);
-               }
-               retval = EX_VAR(opline->result.var);
-               ZVAL_COPY_VALUE(retval, &c->value);
-               if (Z_OPT_COPYABLE_P(retval) || Z_OPT_REFCOUNTED_P(retval)) {
-                       if (Z_OPT_COPYABLE_P(retval)) {
-                               zval_copy_ctor_func(retval);
-                       } else {
-                               Z_ADDREF_P(retval);
+                       ce = zend_fetch_class_by_name(Z_STR_P(opline->op1.zv), opline->op1.zv + 1, ZEND_FETCH_CLASS_DEFAULT TSRMLS_CC);
+                       if (UNEXPECTED(EG(exception) != NULL)) {
+                               HANDLE_EXCEPTION();
+                       }
+                       if (UNEXPECTED(ce == NULL)) {
+                               zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
                        }
+                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op1.zv), ce);
                }
        } else {
-               /* class constant */
-               zend_class_entry *ce;
-               zval *value;
+               ce = Z_CE_P(EX_VAR(opline->op1.var));
+       }
 
-               if (IS_UNUSED == IS_CONST) {
-                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                               value = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                               ZVAL_DEREF(value);
-                               ZVAL_DUP(EX_VAR(opline->result.var), value);
-                               goto constant_fetch_end;
-                       } else if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv))) {
-                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv));
-                       } else {
-                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op1.zv), opline->op1.zv + 1, 0 TSRMLS_CC);
+       if (IS_VAR == IS_CONST &&
+           (IS_TMP_VAR|IS_VAR) == IS_CONST &&
+           CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+               fbc = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+       } else if (IS_VAR != IS_CONST &&
+                  (IS_TMP_VAR|IS_VAR) == IS_CONST &&
+                  (fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce))) {
+               /* do nothing */
+       } else if ((IS_TMP_VAR|IS_VAR) != IS_UNUSED) {
+               zend_free_op free_op2;
+
+               function_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+               if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+                       if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                                if (UNEXPECTED(EG(exception) != NULL)) {
                                        HANDLE_EXCEPTION();
                                }
-                               if (UNEXPECTED(ce == NULL)) {
-                                       zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
-                               }
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op1.zv), ce);
-                       }
+                               zend_error_noreturn(E_ERROR, "Function name must be a string");
+                       }
+               }
+
+               if (ce->get_static_method) {
+                       fbc = ce->get_static_method(ce, Z_STR_P(function_name) TSRMLS_CC);
                } else {
-                       ce = Z_CE_P(EX_VAR(opline->op1.var));
-                       if ((value = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce)) != NULL) {
-                               ZVAL_DEREF(value);
-                               ZVAL_DUP(EX_VAR(opline->result.var), value);
-                               goto constant_fetch_end;
+                       fbc = zend_std_get_static_method(ce, Z_STR_P(function_name), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
+               }
+               if (UNEXPECTED(fbc == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name->val, Z_STRVAL_P(function_name));
+               }
+               if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
+                   EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
+                   EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0)) {
+                       if (IS_VAR == IS_CONST) {
+                               CACHE_PTR(Z_CACHE_SLOT_P(function_name), fbc);
+                       } else {
+                               CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), ce, fbc);
                        }
                }
+               if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+                       zval_ptr_dtor_nogc(free_op2);
+               }
+       } else {
+               if (UNEXPECTED(ce->constructor == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot call constructor");
+               }
+               if (Z_OBJ(EX(This)) && Z_OBJ(EX(This))->ce != ce->constructor->common.scope && (ce->constructor->common.fn_flags & ZEND_ACC_PRIVATE)) {
+                       zend_error_noreturn(E_ERROR, "Cannot call private %s::__construct()", ce->name->val);
+               }
+               fbc = ce->constructor;
+       }
 
-               if (EXPECTED((value = zend_hash_find(&ce->constants_table, Z_STR_P(opline->op2.zv))) != NULL)) {
-                       ZVAL_DEREF(value);
-                       if (Z_CONSTANT_P(value)) {
-                               EG(scope) = ce;
-                               zval_update_constant(value, 1 TSRMLS_CC);
-                               EG(scope) = EX(func)->op_array.scope;
-                       }
-                       if (IS_UNUSED == IS_CONST) {
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), value);
+       object = NULL;
+       if (!(fbc->common.fn_flags & ZEND_ACC_STATIC)) {
+               if (Z_OBJ(EX(This))) {
+                       object = Z_OBJ(EX(This));
+                       GC_REFCOUNT(object)++;
+               }
+               if (!object ||
+                   !instanceof_function(object->ce, ce TSRMLS_CC)) {
+                   /* We are calling method of the other (incompatible) class,
+                      but passing $this. This is done for compatibility with php-4. */
+                       if (fbc->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
+                               zend_error(
+                                       object ? E_DEPRECATED : E_STRICT,
+                                       "Non-static method %s::%s() should not be called statically%s",
+                                       fbc->common.scope->name->val, fbc->common.function_name->val,
+                                       object ? ", assuming $this from incompatible context" : "");
                        } else {
-                               CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce, value);
+                               /* An internal function assumes $this is present and won't check that. So PHP would crash by allowing the call. */
+                               zend_error_noreturn(
+                                       E_ERROR,
+                                       "Non-static method %s::%s() cannot be called statically%s",
+                                       fbc->common.scope->name->val, fbc->common.function_name->val,
+                                       object ? ", assuming $this from incompatible context" : "");
                        }
-                       ZVAL_DUP(EX_VAR(opline->result.var), value);
-               } else if (Z_STRLEN_P(opline->op2.zv) == sizeof("class")-1 && memcmp(Z_STRVAL_P(opline->op2.zv), "class", sizeof("class") - 1) == 0) {
-                       /* "class" is assigned as a case-sensitive keyword from zend_do_resolve_class_name */
-                       ZVAL_STR_COPY(EX_VAR(opline->result.var), ce->name);
-               } else {
-                       zend_error_noreturn(E_ERROR, "Undefined class constant '%s'", Z_STRVAL_P(opline->op2.zv));
                }
        }
-constant_fetch_end:
+
+       if (IS_VAR != IS_CONST) {
+               /* previous opcode is ZEND_FETCH_CLASS */
+               if ((opline-1)->extended_value == ZEND_FETCH_CLASS_PARENT || (opline-1)->extended_value == ZEND_FETCH_CLASS_SELF) {
+                       ce = EX(called_scope);
+               }
+       }
+
+       EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
+               fbc, opline->extended_value, ce, object, EX(call) TSRMLS_CC);
+
+       if ((IS_TMP_VAR|IS_VAR) == IS_UNUSED) {
+               EX(call)->return_value = NULL;
+       }
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *expr_ptr, new_expr;
+
+       SAVE_OPLINE();
+       if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) &&
+           (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
+               expr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+               if (IS_VAR == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
+               }
+               ZVAL_MAKE_REF(expr_ptr);
+               Z_ADDREF_P(expr_ptr);
+               if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
+       } else {
+               expr_ptr = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+               if (IS_VAR == IS_TMP_VAR) {
+                       ZVAL_COPY_VALUE(&new_expr, expr_ptr);
+                       expr_ptr = &new_expr;
+               } else if (IS_VAR == IS_CONST) {
+                       if (!Z_IMMUTABLE_P(expr_ptr)) {
+                               ZVAL_DUP(&new_expr, expr_ptr);
+                               expr_ptr = &new_expr;
+                       }
+               } else if ((IS_VAR == IS_CV || IS_VAR == IS_VAR) && Z_ISREF_P(expr_ptr)) {
+                       expr_ptr = Z_REFVAL_P(expr_ptr);
+                       if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
+                       zval_ptr_dtor_nogc(free_op1);
+               } else if (IS_VAR == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
+                       Z_ADDREF_P(expr_ptr);
+               }
+       }
+
+       if ((IS_TMP_VAR|IS_VAR) != IS_UNUSED) {
+               zend_free_op free_op2;
+               zval *offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+               zend_string *str;
+               zend_ulong hval;
+
+add_again:
+               switch (Z_TYPE_P(offset)) {
+                       case IS_DOUBLE:
+                               hval = zend_dval_to_lval(Z_DVAL_P(offset));
+                               goto num_index;
+                       case IS_LONG:
+                               hval = Z_LVAL_P(offset);
+num_index:
+                               zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
+                               break;
+                       case IS_STRING:
+                               str = Z_STR_P(offset);
+                               if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+                                       if (ZEND_HANDLE_NUMERIC(str, hval)) {
+                                               goto num_index;
+                                       }
+                               }
+str_index:
+                               zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
+                               break;
+                       case IS_NULL:
+                               str = STR_EMPTY_ALLOC();
+                               goto str_index;
+                       case IS_FALSE:
+                               hval = 0;
+                               goto num_index;
+                       case IS_TRUE:
+                               hval = 1;
+                               goto num_index;
+                       case IS_REFERENCE:
+                               offset = Z_REFVAL_P(offset);
+                               goto add_again;
+                               break;
+                       default:
+                               zend_error(E_WARNING, "Illegal offset type");
+                               zval_ptr_dtor(expr_ptr);
+                               /* do nothing */
+                               break;
+               }
+               zval_ptr_dtor_nogc(free_op2);
+       } else {
+               zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
+       }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        zval *array;
        uint32_t size;
        USE_OPLINE
 
        array = EX_VAR(opline->result.var);
-       if (IS_UNUSED != IS_UNUSED) {
+       if (IS_VAR != IS_UNUSED) {
                size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
        } else {
                size = 0;
@@ -27774,42 +22103,42 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_
        ZVAL_NEW_ARR(array);
        zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
 
-       if (IS_UNUSED != IS_UNUSED) {
+       if (IS_VAR != IS_UNUSED) {
                /* Explicitly initialize array as not-packed if flag is set */
                if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
                        zend_hash_real_init(Z_ARRVAL_P(array), 0);
                }
        }
 
-       if (IS_UNUSED == IS_UNUSED) {
+       if (IS_VAR == IS_UNUSED) {
                ZEND_VM_NEXT_OPCODE();
-#if 0 || IS_UNUSED != IS_UNUSED
+#if 0 || IS_VAR != IS_UNUSED
        } else {
-               return ZEND_ADD_ARRAY_ELEMENT_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 #endif
        }
 }
 
-static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
+       zend_free_op free_op1, free_op2;
        zval *container;
        zval *offset;
        zend_ulong hval;
 
        SAVE_OPLINE();
-       container = _get_obj_zval_ptr_unused(execute_data);
-       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
        }
-       if (IS_UNUSED != IS_UNUSED) {
+       if (IS_VAR != IS_UNUSED) {
                ZVAL_DEREF(container);
        }
        SEPARATE_ZVAL_NOREF(container);
-       offset = opline->op2.zv;
+       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if (IS_UNUSED != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
+       if (IS_VAR != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
                HashTable *ht = Z_ARRVAL_P(container);
 offset_again:
                switch (Z_TYPE_P(offset)) {
@@ -27823,7 +22152,7 @@ num_index_dim:
                                zend_hash_index_del(ht, hval);
                                break;
                        case IS_STRING:
-                               if (IS_CONST != IS_CONST) {
+                               if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
                                        if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
                                                goto num_index_dim;
                                        }
@@ -27854,71 +22183,71 @@ num_index_dim:
                                zend_error(E_WARNING, "Illegal offset type in unset");
                                break;
                }
-
-       } else if (IS_UNUSED == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+               zval_ptr_dtor_nogc(free_op2);
+       } else if (IS_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
                if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use object as array");
                }
-//???          if (IS_CONST == IS_CONST) {
+//???          if ((IS_TMP_VAR|IS_VAR) == IS_CONST) {
 //???                  zval_copy_ctor(offset);
 //???          }
                Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
-
+               zval_ptr_dtor_nogc(free_op2);
        } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
                zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
                ZEND_VM_CONTINUE(); /* bailed out before */
        } else {
-
+               zval_ptr_dtor_nogc(free_op2);
        }
-
+       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
+       zend_free_op free_op1, free_op2;
        zval *container;
        zval *offset;
 
        SAVE_OPLINE();
-       container = _get_obj_zval_ptr_unused(execute_data);
-       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+       container = _get_zval_ptr_ptr_var(opline->op1.var, execute_data, &free_op1);
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
        }
-       offset = opline->op2.zv;
+       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if (IS_UNUSED != IS_UNUSED) {
+       if (IS_VAR != IS_UNUSED) {
                ZVAL_DEREF(container);
        }
-       if (IS_UNUSED == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
+       if (IS_VAR == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
                if (Z_OBJ_HT_P(container)->unset_property) {
-                       Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+                       Z_OBJ_HT_P(container)->unset_property(container, offset, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
                } else {
                        zend_error(E_NOTICE, "Trying to unset property of non-object");
                }
        }
-
-
+       zval_ptr_dtor_nogc(free_op2);
+       if (free_op1) {zval_ptr_dtor_nogc(free_op1);};
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
+       zend_free_op free_op1, free_op2;
        zval *container;
        int result;
        zend_ulong hval;
        zval *offset;
 
        SAVE_OPLINE();
-       container = _get_obj_zval_ptr_unused(execute_data);
-       offset = opline->op2.zv;
+       container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
+       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if (IS_UNUSED != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
+       if (IS_VAR != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
                HashTable *ht = Z_ARRVAL_P(container);
                zval *value;
                zend_string *str;
@@ -27926,7 +22255,7 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_CONST_HANDLER(Z
 isset_again:
                if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
                        str = Z_STR_P(offset);
-                       if (IS_CONST != IS_CONST) {
+                       if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
                                if (ZEND_HANDLE_NUMERIC(str, hval)) {
                                        goto num_index_prop;
                                }
@@ -27971,7 +22300,7 @@ num_index_prop:
                } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
                        result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
                }
-       } else if (IS_UNUSED == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+       } else if (IS_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
                if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
                        result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
                } else {
@@ -27986,7 +22315,7 @@ num_index_prop:
 
                result = 0;
                if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
-                       if (IS_CONST == IS_CV || IS_CONST == IS_VAR) {
+                       if ((IS_TMP_VAR|IS_VAR) & (IS_CV|IS_VAR)) {
                                ZVAL_DEREF(offset);
                        }
                        if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
@@ -28012,27 +22341,28 @@ num_index_prop:
                result = ((opline->extended_value & ZEND_ISSET) == 0);
        }
 
+       zval_ptr_dtor_nogc(free_op2);
        ZVAL_BOOL(EX_VAR(opline->result.var), result);
-
+       zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
+       zend_free_op free_op1, free_op2;
        zval *container;
        int result;
        zval *offset;
 
        SAVE_OPLINE();
-       container = _get_obj_zval_ptr_unused(execute_data);
-       offset = opline->op2.zv;
+       container = _get_zval_ptr_var_deref(opline->op1.var, execute_data, &free_op1);
+       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if (IS_UNUSED == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+       if (IS_VAR == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
                if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
-                       result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+                       result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
                } else {
                        zend_error(E_NOTICE, "Trying to check property of non-object");
                        result = 0;
@@ -28044,154 +22374,99 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_CONST_HANDLER(
                result = ((opline->extended_value & ZEND_ISSET) == 0);
        }
 
+       zval_ptr_dtor_nogc(free_op2);
        ZVAL_BOOL(EX_VAR(opline->result.var), result);
-
+       zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_YIELD_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_CLONE_SPEC_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       /* The generator object is stored in EX(return_value) */
-       zend_generator *generator = (zend_generator *) EX(return_value);
-
-       if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
-               zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
-       }
-
-       /* Destroy the previously yielded value */
-       zval_ptr_dtor(&generator->value);
-
-       /* Destroy the previously yielded key */
-       zval_ptr_dtor(&generator->key);
-
-       /* Set the new yielded value */
-       if (IS_UNUSED != IS_UNUSED) {
-
-
-               if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
-                       /* Constants and temporary variables aren't yieldable by reference,
-                        * but we still allow them with a notice. */
-                       if (IS_UNUSED == IS_CONST || IS_UNUSED == IS_TMP_VAR) {
-                               zval *value;
-
-                               zend_error(E_NOTICE, "Only variable references should be yielded by reference");
-
-                               value = NULL;
-                               ZVAL_COPY_VALUE(&generator->value, value);
-                               if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
-
-                               /* Temporary variables don't need ctor copying */
-                               if (IS_UNUSED != IS_TMP_VAR) {
-                                       zval_opt_copy_ctor(&generator->value);
-                               }
-                       } else {
-                               zval *value_ptr = NULL;
+       zval *obj;
+       zend_class_entry *ce;
+       zend_function *clone;
+       zend_object_clone_obj_t clone_call;
 
-                               if (IS_UNUSED == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
-                                       zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
-                               }
+       SAVE_OPLINE();
+       obj = _get_obj_zval_ptr_unused(execute_data);
 
-                               /* If a function call result is yielded and the function did
-                                * not return by reference we throw a notice. */
-                               if (IS_UNUSED == IS_VAR &&
-                                   (value_ptr == &EG(uninitialized_zval) ||
-                                    (opline->extended_value == ZEND_RETURNS_FUNCTION &&
-                                     !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
-                                       zend_error(E_NOTICE, "Only variable references should be yielded by reference");
-                               } else {
-                                       ZVAL_MAKE_REF(value_ptr);
-                               }
-                               ZVAL_COPY(&generator->value, value_ptr);
+       if (IS_UNUSED == IS_CONST ||
+           (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(obj) != IS_OBJECT))) {
+               if (UNEXPECTED(EG(exception) != NULL)) {
+                       HANDLE_EXCEPTION();
+               }
+               zend_error_noreturn(E_ERROR, "__clone method called on non-object");
+       }
 
-                       }
+       ce = Z_OBJCE_P(obj);
+       clone = ce ? ce->clone : NULL;
+       clone_call =  Z_OBJ_HT_P(obj)->clone_obj;
+       if (UNEXPECTED(clone_call == NULL)) {
+               if (ce) {
+                       zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object of class %s", ce->name->val);
                } else {
-                       zval *value = NULL;
-
-                       /* Consts, temporary variables and references need copying */
-                       if (IS_UNUSED == IS_CONST) {
-                               ZVAL_DUP(&generator->value, value);
-                       } else if (IS_UNUSED == IS_TMP_VAR) {
-                               ZVAL_COPY_VALUE(&generator->value, value);
-            } else if ((IS_UNUSED == IS_CV || IS_UNUSED == IS_VAR) && Z_ISREF_P(value)) {
-                               ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
-
-                       } else {
-                               ZVAL_COPY_VALUE(&generator->value, value);
-                               if (IS_UNUSED == IS_CV) {
-                                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
-                               }
-                       }
+                       zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object");
                }
-       } else {
-               /* If no value was specified yield null */
-               ZVAL_NULL(&generator->value);
        }
 
-       /* Set the new yielded key */
-       if (IS_CONST != IS_UNUSED) {
-
-               zval *key = opline->op2.zv;
-
-               /* Consts, temporary variables and references need copying */
-               if (IS_CONST == IS_CONST) {
-                       ZVAL_DUP(&generator->key, key);
-               } else if (IS_CONST == IS_TMP_VAR) {
-                       ZVAL_COPY_VALUE(&generator->key, key);
-               } else if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) && Z_ISREF_P(key)) {
-                       ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
-
-               } else {
-                       ZVAL_COPY_VALUE(&generator->key, key);
-                       if (IS_CONST == IS_CV) {
-                               if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
+       if (ce && clone) {
+               if (clone->op_array.fn_flags & ZEND_ACC_PRIVATE) {
+                       /* Ensure that if we're calling a private function, we're allowed to do so.
+                        */
+                       if (UNEXPECTED(ce != EG(scope))) {
+                               zend_error_noreturn(E_ERROR, "Call to private %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
+                       }
+               } else if ((clone->common.fn_flags & ZEND_ACC_PROTECTED)) {
+                       /* Ensure that if we're calling a protected function, we're allowed to do so.
+                        */
+                       if (UNEXPECTED(!zend_check_protected(zend_get_function_root_class(clone), EG(scope)))) {
+                               zend_error_noreturn(E_ERROR, "Call to protected %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
                        }
                }
+       }
 
-               if (Z_TYPE(generator->key) == IS_LONG
-                   && Z_LVAL(generator->key) > generator->largest_used_integer_key
-               ) {
-                       generator->largest_used_integer_key = Z_LVAL(generator->key);
+       if (EXPECTED(EG(exception) == NULL)) {
+               ZVAL_OBJ(EX_VAR(opline->result.var), clone_call(obj TSRMLS_CC));
+               if (!RETURN_VALUE_USED(opline) || UNEXPECTED(EG(exception) != NULL)) {
+                       OBJ_RELEASE(Z_OBJ_P(EX_VAR(opline->result.var)));
                }
-       } else {
-               /* If no key was specified we use auto-increment keys */
-               generator->largest_used_integer_key++;
-               ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
        }
 
-       if (RETURN_VALUE_USED(opline)) {
-               /* If the return value of yield is used set the send
-                * target and initialize it to NULL */
-               generator->send_target = EX_VAR(opline->result.var);
-               ZVAL_NULL(generator->send_target);
-       } else {
-               generator->send_target = NULL;
-       }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       /* We increment to the next op, so we are at the correct position when the
-        * generator is resumed. */
-       ZEND_VM_INC_OPCODE();
+static int ZEND_FASTCALL  ZEND_EXIT_SPEC_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+#if 0 || (IS_UNUSED != IS_UNUSED)
+       USE_OPLINE
 
-       /* The GOTO VM uses a local opline variable. We need to set the opline
-        * variable in execute_data so we don't resume at an old position. */
        SAVE_OPLINE();
+       if (IS_UNUSED != IS_UNUSED) {
 
-       ZEND_VM_RETURN();
-}
+               zval *ptr = NULL;
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_POW_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               if (Z_TYPE_P(ptr) == IS_LONG) {
+                       EG(exit_status) = Z_LVAL_P(ptr);
+               } else {
+                       zend_print_variable(ptr TSRMLS_CC);
+               }
+
+       }
+#endif
+       zend_bailout();
+       ZEND_VM_NEXT_OPCODE(); /* Never reached */
 }
 
-static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2, free_op_data1;
+       zend_free_op free_op_data1;
        zval *object = _get_obj_zval_ptr_unused(execute_data);
-       zval *property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       zval *property = opline->op2.zv;
        zval *value;
        zval *zptr;
 
@@ -28207,7 +22482,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(int (*
 
        if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to assign property of non-object");
-               zval_ptr_dtor_nogc(free_op2);
+
                FREE_OP(free_op_data1);
 
                if (RETURN_VALUE_USED(opline)) {
@@ -28217,7 +22492,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(int (*
                /* here we are sure we are dealing with an object */
                if (opline->extended_value == ZEND_ASSIGN_OBJ
                        && EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-                       && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+                       && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
 
                        ZVAL_DEREF(zptr);
                        SEPARATE_ZVAL_NOREF(zptr);
@@ -28232,7 +22507,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(int (*
 
                        if (opline->extended_value == ZEND_ASSIGN_OBJ) {
                                if (Z_OBJ_HT_P(object)->read_property) {
-                                       z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+                                       z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
                                }
                        } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
                                if (Z_OBJ_HT_P(object)->read_dimension) {
@@ -28253,7 +22528,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(int (*
                                SEPARATE_ZVAL_IF_NOT_REF(z);
                                binary_op(z, z, value TSRMLS_CC);
                                if (opline->extended_value == ZEND_ASSIGN_OBJ) {
-                                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+                                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
                                } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
                                        Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
                                }
@@ -28269,7 +22544,6 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(int (*
                        }
                }
 
-               zval_ptr_dtor_nogc(free_op2);
                FREE_OP(free_op_data1);
        }
 
@@ -28279,10 +22553,10 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(int (*
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2, free_op_data1;
+       zend_free_op free_op_data1;
        zval *var_ptr, rv;
        zval *value, *container;
 
@@ -28298,11 +22572,11 @@ static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(int (*
                if (IS_UNUSED == IS_VAR && !0) {
                        Z_ADDREF_P(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
                }
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else {
-               zval *dim = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+               zval *dim = opline->op2.zv;
 
-               zend_fetch_dimension_address_RW(&rv, container, dim, IS_TMP_VAR TSRMLS_CC);
+               zend_fetch_dimension_address_RW(&rv, container, dim, IS_CONST TSRMLS_CC);
                value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
                ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
                var_ptr = Z_INDIRECT(rv);
@@ -28327,7 +22601,6 @@ static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(int (*
                }
        }
 
-       zval_ptr_dtor_nogc(free_op2);
        FREE_OP(free_op_data1);
 
        CHECK_EXCEPTION();
@@ -28335,15 +22608,15 @@ static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(int (*
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
+
        zval *var_ptr;
        zval *value;
 
        SAVE_OPLINE();
-       value = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       value = opline->op2.zv;
        var_ptr = NULL;
 
        if (IS_UNUSED == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
@@ -28365,159 +22638,158 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_TMP(int (*bina
                }
        }
 
-       zval_ptr_dtor_nogc(free_op2);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_ADD_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_ADD_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SUB_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_SUB_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_MUL_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_MUL_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_DIV_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_DIV_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_MOD_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_MOD_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SL_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_SL_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SR_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_SR_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_CONCAT_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_CONCAT_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_OR_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_OR_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_AND_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_AND_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_TMP(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
+
        zval *object;
        zval *property;
        zval *retval;
@@ -28525,7 +22797,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_TMP(incdec_
 
        SAVE_OPLINE();
        object = _get_obj_zval_ptr_unused(execute_data);
-       property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       property = opline->op2.zv;
        retval = EX_VAR(opline->result.var);
 
        if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
@@ -28538,7 +22810,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_TMP(incdec_
 
        if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-               zval_ptr_dtor_nogc(free_op2);
+
                if (RETURN_VALUE_USED(opline)) {
                        ZVAL_NULL(retval);
                }
@@ -28550,7 +22822,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_TMP(incdec_
        /* here we are sure we are dealing with an object */
 
        if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
 
                ZVAL_DEREF(zptr);
                SEPARATE_ZVAL_NOREF(zptr);
@@ -28563,7 +22835,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_TMP(incdec_
                zval rv;
 
                if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
-                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
 
                        if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval rv;
@@ -28578,7 +22850,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_TMP(incdec_
                        SEPARATE_ZVAL_IF_NOT_REF(z);
                        incdec_op(z);
                        ZVAL_COPY_VALUE(retval, z);
-                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
                        SELECTIVE_PZVAL_LOCK(retval, opline);
                        zval_ptr_dtor(z);
                } else {
@@ -28589,26 +22861,25 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_TMP(incdec_
                }
        }
 
-       zval_ptr_dtor_nogc(free_op2);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_PRE_INC_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_PRE_INC_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_pre_incdec_property_helper_SPEC_UNUSED_TMP(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_pre_incdec_property_helper_SPEC_UNUSED_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_pre_incdec_property_helper_SPEC_UNUSED_TMP(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_pre_incdec_property_helper_SPEC_UNUSED_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_TMP(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
+
        zval *object;
        zval *property;
        zval *retval;
@@ -28616,7 +22887,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_TMP(incdec
 
        SAVE_OPLINE();
        object = _get_obj_zval_ptr_unused(execute_data);
-       property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       property = opline->op2.zv;
        retval = EX_VAR(opline->result.var);
 
        if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
@@ -28629,7 +22900,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_TMP(incdec
 
        if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-               zval_ptr_dtor_nogc(free_op2);
+
                ZVAL_NULL(retval);
 
                CHECK_EXCEPTION();
@@ -28639,7 +22910,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_TMP(incdec
        /* here we are sure we are dealing with an object */
 
        if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
 
                ZVAL_DEREF(zptr);
                ZVAL_COPY_VALUE(retval, zptr);
@@ -28649,7 +22920,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_TMP(incdec
        } else {
                if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
                        zval rv;
-                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
                        zval z_copy;
 
                        if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
@@ -28665,7 +22936,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_TMP(incdec
                        ZVAL_DUP(&z_copy, z);
                        incdec_op(&z_copy);
                        if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
-                       Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+                       Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
                        zval_ptr_dtor(&z_copy);
                        zval_ptr_dtor(z);
                } else {
@@ -28674,33 +22945,32 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_TMP(incdec
                }
        }
 
-       zval_ptr_dtor_nogc(free_op2);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_POST_INC_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_POST_INC_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_post_incdec_property_helper_SPEC_UNUSED_TMP(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_post_incdec_property_helper_SPEC_UNUSED_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_post_incdec_property_helper_SPEC_UNUSED_TMP(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_post_incdec_property_helper_SPEC_UNUSED_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        zval *container;
-       zend_free_op free_op2;
+
        zval *offset;
 
        SAVE_OPLINE();
        container = _get_obj_zval_ptr_unused(execute_data);
-       offset  = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       offset  = opline->op2.zv;
 
        if ((IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
            UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
@@ -28711,7 +22981,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_H
 
                /* here we are sure we are dealing with an object */
                do {
-                       if (IS_TMP_VAR == IS_CONST &&
+                       if (IS_CONST == IS_CONST &&
                                EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
                                zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
                                zend_object *zobj = Z_OBJ_P(container);
@@ -28731,7 +23001,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_H
                                }
                        }
 
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
 
                        if (retval != EX_VAR(opline->result.var)) {
                                ZVAL_COPY(EX_VAR(opline->result.var), retval);
@@ -28739,29 +23009,28 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_H
                } while (0);
        }
 
-       zval_ptr_dtor_nogc(free_op2);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
        zval *property;
        zval *container;
 
        SAVE_OPLINE();
-       property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       property = opline->op2.zv;
 
        container = _get_obj_zval_ptr_unused(execute_data);
        if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
 
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
+       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+
        if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
                EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
@@ -28770,22 +23039,22 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_H
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
        zval *property;
        zval *container;
 
        SAVE_OPLINE();
-       property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       property = opline->op2.zv;
        container = _get_obj_zval_ptr_unused(execute_data);
 
        if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
+       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
+
        if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
                EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
@@ -28794,17 +23063,17 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        zval *container;
-       zend_free_op free_op2;
+
        zval *offset;
 
        SAVE_OPLINE();
        container = _get_obj_zval_ptr_unused(execute_data);
-       offset  = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       offset  = opline->op2.zv;
 
        if ((IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
            UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
@@ -28814,7 +23083,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_
 
                /* here we are sure we are dealing with an object */
                do {
-                       if (IS_TMP_VAR == IS_CONST &&
+                       if (IS_CONST == IS_CONST &&
                                EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
                                zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
                                zend_object *zobj = Z_OBJ_P(container);
@@ -28834,7 +23103,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_
                                }
                        }
 
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
 
                        if (retval != EX_VAR(opline->result.var)) {
                                ZVAL_COPY(EX_VAR(opline->result.var), retval);
@@ -28842,24 +23111,23 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_
                } while (0);
        }
 
-       zval_ptr_dtor_nogc(free_op2);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zval *container;
 
        if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
                /* Behave like FETCH_OBJ_W */
-               zend_free_op free_op1, free_op2;
+               zend_free_op free_op1;
                zval *property;
 
                SAVE_OPLINE();
-               property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+               property = opline->op2.zv;
                container = _get_obj_zval_ptr_unused(execute_data);
 
         if (IS_UNUSED == IS_CONST || IS_UNUSED == IS_TMP_VAR) {
@@ -28868,8 +23136,8 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_TMP_HANDLER(ZEND_O
                if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
                }
-               zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op2);
+               zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+
                if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
                        EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
                }
@@ -28877,25 +23145,25 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_TMP_HANDLER(ZEND_O
                CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
-               return ZEND_FETCH_OBJ_R_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return ZEND_FETCH_OBJ_R_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op1;
        zval *container, *property;
 
        SAVE_OPLINE();
        container = _get_obj_zval_ptr_unused(execute_data);
-       property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       property = opline->op2.zv;
 
        if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
+       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
+
        if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
                EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
@@ -28904,22 +23172,22 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCO
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
+
        zval *object;
        zval *property_name;
 
        SAVE_OPLINE();
        object = _get_obj_zval_ptr_unused(execute_data);
-       property_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       property_name = opline->op2.zv;
 
        if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_UNUSED, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
+       zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_UNUSED, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+
 
        /* assign_obj has two opcodes! */
        CHECK_EXCEPTION();
@@ -28927,57 +23195,49 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HA
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ADD_VAR_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ADD_CHAR_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
        zval *str = EX_VAR(opline->result.var);
-       zval *var;
-       zval var_copy;
-       int use_copy = 0;
 
        SAVE_OPLINE();
-       var = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
 
        if (IS_UNUSED == IS_UNUSED) {
-               /* Initialize for erealloc in add_string_to_string */
+               /* Initialize for erealloc in add_char_to_string */
                ZVAL_EMPTY_STRING(str);
        }
 
-       if (Z_TYPE_P(var) != IS_STRING) {
-               if (IS_TMP_VAR != IS_TMP_VAR) {
-                       ZVAL_DEREF(var);
-               }
-               if (Z_TYPE_P(var) != IS_STRING) {
-                       use_copy = zend_make_printable_zval(var, &var_copy TSRMLS_CC);
+       add_char_to_string(str, str, opline->op2.zv);
 
-                       if (use_copy) {
-                               var = &var_copy;
-                       }
-               }
-       }
-       add_string_to_string(str, str, var);
+       /* FREE_OP is missing intentionally here - we're always working on the same temporary variable */
+       /*CHECK_EXCEPTION();*/
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_ADD_STRING_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zval *str = EX_VAR(opline->result.var);
 
-       if (use_copy) {
-               zend_string_release(Z_STR_P(var));
+       SAVE_OPLINE();
+
+       if (IS_UNUSED == IS_UNUSED) {
+               /* Initialize for erealloc in add_string_to_string */
+               ZVAL_EMPTY_STRING(str);
        }
-       /* original comment, possibly problematic:
-        * FREE_OP is missing intentionally here - we're always working on the same temporary variable
-        * (Zeev):  I don't think it's problematic, we only use variables
-        * which aren't affected by FREE_OP(Ts, )'s anyway, unless they're
-        * string offsets or overloaded objects
-        */
-       zval_ptr_dtor_nogc(free_op2);
 
-       CHECK_EXCEPTION();
+       add_string_to_string(str, str, opline->op2.zv);
+
+       /* FREE_OP is missing intentionally here - we're always working on the same temporary variable */
+       /*CHECK_EXCEPTION();*/
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zval *function_name;
-       zend_free_op free_op2;
+
        zval *object;
        zend_function *fbc;
        zend_class_entry *called_scope;
@@ -28985,9 +23245,9 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_TMP_HANDLER(ZEND_OPC
 
        SAVE_OPLINE();
 
-       function_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       function_name = opline->op2.zv;
 
-       if (IS_TMP_VAR != IS_CONST &&
+       if (IS_CONST != IS_CONST &&
            UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                if (UNEXPECTED(EG(exception) != NULL)) {
                        HANDLE_EXCEPTION();
@@ -29001,12 +23261,12 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_TMP_HANDLER(ZEND_OPC
                uint32_t nesting = 1;
 
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       zval_ptr_dtor_nogc(free_op2);
+
                        HANDLE_EXCEPTION();
                }
 
                zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s",  Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
-               zval_ptr_dtor_nogc(free_op2);
+
 
                if (EG(exception) != NULL) {
                        HANDLE_EXCEPTION();
@@ -29044,7 +23304,7 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_TMP_HANDLER(ZEND_OPC
        obj = Z_OBJ_P(object);
        called_scope = obj->ce;
 
-       if (IS_TMP_VAR != IS_CONST ||
+       if (IS_CONST != IS_CONST ||
            EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
            zend_object *orig_obj = obj;
 
@@ -29053,11 +23313,11 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_TMP_HANDLER(ZEND_OPC
                }
 
                /* First, locate the function. */
-               fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_TMP_VAR == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
+               fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_CONST == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
                if (UNEXPECTED(fbc == NULL)) {
                        zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
                }
-               if (IS_TMP_VAR == IS_CONST &&
+               if (IS_CONST == IS_CONST &&
                    EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
                    EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
                    EXPECTED(obj == orig_obj)) {
@@ -29074,13 +23334,110 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_TMP_HANDLER(ZEND_OPC
        EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
                fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
 
-       zval_ptr_dtor_nogc(free_op2);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_CONSTANT_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       SAVE_OPLINE();
+       if (IS_UNUSED == IS_UNUSED) {
+               zend_constant *c;
+               zval *retval;
+
+               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                       c = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+               } else if ((c = zend_quick_get_constant(opline->op2.zv + 1, opline->extended_value TSRMLS_CC)) == NULL) {
+                       if ((opline->extended_value & IS_CONSTANT_UNQUALIFIED) != 0) {
+                               char *actual = (char *)zend_memrchr(Z_STRVAL_P(opline->op2.zv), '\\', Z_STRLEN_P(opline->op2.zv));
+                               if (!actual) {
+                                       ZVAL_STR(EX_VAR(opline->result.var), zend_string_copy(Z_STR_P(opline->op2.zv)));
+                               } else {
+                                       actual++;
+                                       ZVAL_STRINGL(EX_VAR(opline->result.var),
+                                                       actual, Z_STRLEN_P(opline->op2.zv) - (actual - Z_STRVAL_P(opline->op2.zv)));
+                               }
+                               /* non-qualified constant - allow text substitution */
+                               zend_error(E_NOTICE, "Use of undefined constant %s - assumed '%s'",
+                                               Z_STRVAL_P(EX_VAR(opline->result.var)), Z_STRVAL_P(EX_VAR(opline->result.var)));
+                               CHECK_EXCEPTION();
+                               ZEND_VM_NEXT_OPCODE();
+                       } else {
+                               zend_error_noreturn(E_ERROR, "Undefined constant '%s'", Z_STRVAL_P(opline->op2.zv));
+                       }
+               } else {
+                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), c);
+               }
+               retval = EX_VAR(opline->result.var);
+               ZVAL_COPY_VALUE(retval, &c->value);
+               if (Z_OPT_COPYABLE_P(retval) || Z_OPT_REFCOUNTED_P(retval)) {
+                       if (Z_OPT_COPYABLE_P(retval)) {
+                               zval_copy_ctor_func(retval);
+                       } else {
+                               Z_ADDREF_P(retval);
+                       }
+               }
+       } else {
+               /* class constant */
+               zend_class_entry *ce;
+               zval *value;
+
+               if (IS_UNUSED == IS_CONST) {
+                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                               value = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+                               ZVAL_DEREF(value);
+                               ZVAL_DUP(EX_VAR(opline->result.var), value);
+                               goto constant_fetch_end;
+                       } else if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv))) {
+                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op1.zv));
+                       } else {
+                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op1.zv), opline->op1.zv + 1, 0 TSRMLS_CC);
+                               if (UNEXPECTED(EG(exception) != NULL)) {
+                                       HANDLE_EXCEPTION();
+                               }
+                               if (UNEXPECTED(ce == NULL)) {
+                                       zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
+                               }
+                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op1.zv), ce);
+                       }
+               } else {
+                       ce = Z_CE_P(EX_VAR(opline->op1.var));
+                       if ((value = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce)) != NULL) {
+                               ZVAL_DEREF(value);
+                               ZVAL_DUP(EX_VAR(opline->result.var), value);
+                               goto constant_fetch_end;
+                       }
+               }
+
+               if (EXPECTED((value = zend_hash_find(&ce->constants_table, Z_STR_P(opline->op2.zv))) != NULL)) {
+                       ZVAL_DEREF(value);
+                       if (Z_CONSTANT_P(value)) {
+                               EG(scope) = ce;
+                               zval_update_constant(value, 1 TSRMLS_CC);
+                               EG(scope) = EX(func)->op_array.scope;
+                       }
+                       if (IS_UNUSED == IS_CONST) {
+                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), value);
+                       } else {
+                               CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce, value);
+                       }
+                       ZVAL_DUP(EX_VAR(opline->result.var), value);
+               } else if (Z_STRLEN_P(opline->op2.zv) == sizeof("class")-1 && memcmp(Z_STRVAL_P(opline->op2.zv), "class", sizeof("class") - 1) == 0) {
+                       /* "class" is assigned as a case-sensitive keyword from zend_do_resolve_class_name */
+                       ZVAL_STR_COPY(EX_VAR(opline->result.var), ce->name);
+               } else {
+                       zend_error_noreturn(E_ERROR, "Undefined class constant '%s'", Z_STRVAL_P(opline->op2.zv));
+               }
+       }
+constant_fetch_end:
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        zval *array;
        uint32_t size;
@@ -29106,15 +23463,15 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HA
                ZEND_VM_NEXT_OPCODE();
 #if 0 || IS_UNUSED != IS_UNUSED
        } else {
-               return ZEND_ADD_ARRAY_ELEMENT_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return ZEND_ADD_ARRAY_ELEMENT_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 #endif
        }
 }
 
-static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
+
        zval *container;
        zval *offset;
        zend_ulong hval;
@@ -29128,7 +23485,7 @@ static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HAN
                ZVAL_DEREF(container);
        }
        SEPARATE_ZVAL_NOREF(container);
-       offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       offset = opline->op2.zv;
 
        if (IS_UNUSED != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
                HashTable *ht = Z_ARRVAL_P(container);
@@ -29144,7 +23501,7 @@ num_index_dim:
                                zend_hash_index_del(ht, hval);
                                break;
                        case IS_STRING:
-                               if (IS_TMP_VAR != IS_CONST) {
+                               if (IS_CONST != IS_CONST) {
                                        if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
                                                goto num_index_dim;
                                        }
@@ -29175,31 +23532,31 @@ num_index_dim:
                                zend_error(E_WARNING, "Illegal offset type in unset");
                                break;
                }
-               zval_ptr_dtor_nogc(free_op2);
+
        } else if (IS_UNUSED == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
                if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use object as array");
                }
-//???          if (IS_TMP_VAR == IS_CONST) {
+//???          if (IS_CONST == IS_CONST) {
 //???                  zval_copy_ctor(offset);
 //???          }
                Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op2);
+
        } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
                zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
                ZEND_VM_CONTINUE(); /* bailed out before */
        } else {
-               zval_ptr_dtor_nogc(free_op2);
+
        }
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
+
        zval *container;
        zval *offset;
 
@@ -29208,28 +23565,28 @@ static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HAN
        if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
        }
-       offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       offset = opline->op2.zv;
 
        if (IS_UNUSED != IS_UNUSED) {
                ZVAL_DEREF(container);
        }
        if (IS_UNUSED == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
                if (Z_OBJ_HT_P(container)->unset_property) {
-                       Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+                       Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
                } else {
                        zend_error(E_NOTICE, "Trying to unset property of non-object");
                }
        }
-       zval_ptr_dtor_nogc(free_op2);
+
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
+
        zval *container;
        int result;
        zend_ulong hval;
@@ -29237,7 +23594,7 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEN
 
        SAVE_OPLINE();
        container = _get_obj_zval_ptr_unused(execute_data);
-       offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       offset = opline->op2.zv;
 
        if (IS_UNUSED != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
                HashTable *ht = Z_ARRVAL_P(container);
@@ -29247,7 +23604,7 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEN
 isset_again:
                if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
                        str = Z_STR_P(offset);
-                       if (IS_TMP_VAR != IS_CONST) {
+                       if (IS_CONST != IS_CONST) {
                                if (ZEND_HANDLE_NUMERIC(str, hval)) {
                                        goto num_index_prop;
                                }
@@ -29307,7 +23664,7 @@ num_index_prop:
 
                result = 0;
                if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
-                       if (IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) {
+                       if (IS_CONST & (IS_CV|IS_VAR)) {
                                ZVAL_DEREF(offset);
                        }
                        if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
@@ -29333,28 +23690,27 @@ num_index_prop:
                result = ((opline->extended_value & ZEND_ISSET) == 0);
        }
 
-       zval_ptr_dtor_nogc(free_op2);
        ZVAL_BOOL(EX_VAR(opline->result.var), result);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
+
        zval *container;
        int result;
        zval *offset;
 
        SAVE_OPLINE();
        container = _get_obj_zval_ptr_unused(execute_data);
-       offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       offset = opline->op2.zv;
 
        if (IS_UNUSED == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
                if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
-                       result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+                       result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
                } else {
                        zend_error(E_NOTICE, "Trying to check property of non-object");
                        result = 0;
@@ -29366,14 +23722,13 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_TMP_HANDLER(ZE
                result = ((opline->extended_value & ZEND_ISSET) == 0);
        }
 
-       zval_ptr_dtor_nogc(free_op2);
        ZVAL_BOOL(EX_VAR(opline->result.var), result);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_YIELD_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_YIELD_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
@@ -29454,21 +23809,21 @@ static int ZEND_FASTCALL  ZEND_YIELD_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER
        }
 
        /* Set the new yielded key */
-       if (IS_TMP_VAR != IS_UNUSED) {
-               zend_free_op free_op2;
-               zval *key = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       if (IS_CONST != IS_UNUSED) {
+
+               zval *key = opline->op2.zv;
 
                /* Consts, temporary variables and references need copying */
-               if (IS_TMP_VAR == IS_CONST) {
+               if (IS_CONST == IS_CONST) {
                        ZVAL_DUP(&generator->key, key);
-               } else if (IS_TMP_VAR == IS_TMP_VAR) {
+               } else if (IS_CONST == IS_TMP_VAR) {
                        ZVAL_COPY_VALUE(&generator->key, key);
-               } else if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && Z_ISREF_P(key)) {
+               } else if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) && Z_ISREF_P(key)) {
                        ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
 
                } else {
                        ZVAL_COPY_VALUE(&generator->key, key);
-                       if (IS_TMP_VAR == IS_CV) {
+                       if (IS_CONST == IS_CV) {
                                if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
                        }
                }
@@ -29504,17 +23859,17 @@ static int ZEND_FASTCALL  ZEND_YIELD_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER
        ZEND_VM_RETURN();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_POW_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_POW_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_binary_assign_op_helper_SPEC_UNUSED_CONST(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op2, free_op_data1;
        zval *object = _get_obj_zval_ptr_unused(execute_data);
-       zval *property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+       zval *property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
        zval *value;
        zval *zptr;
 
@@ -29540,7 +23895,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(int (*
                /* here we are sure we are dealing with an object */
                if (opline->extended_value == ZEND_ASSIGN_OBJ
                        && EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-                       && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+                       && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
 
                        ZVAL_DEREF(zptr);
                        SEPARATE_ZVAL_NOREF(zptr);
@@ -29555,7 +23910,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(int (*
 
                        if (opline->extended_value == ZEND_ASSIGN_OBJ) {
                                if (Z_OBJ_HT_P(object)->read_property) {
-                                       z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+                                       z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
                                }
                        } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
                                if (Z_OBJ_HT_P(object)->read_dimension) {
@@ -29576,7 +23931,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(int (*
                                SEPARATE_ZVAL_IF_NOT_REF(z);
                                binary_op(z, z, value TSRMLS_CC);
                                if (opline->extended_value == ZEND_ASSIGN_OBJ) {
-                                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+                                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
                                } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
                                        Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
                                }
@@ -29602,7 +23957,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(int (*
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op2, free_op_data1;
@@ -29621,11 +23976,11 @@ static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(int (*
                if (IS_UNUSED == IS_VAR && !0) {
                        Z_ADDREF_P(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
                }
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else {
-               zval *dim = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+               zval *dim = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
 
-               zend_fetch_dimension_address_RW(&rv, container, dim, IS_VAR TSRMLS_CC);
+               zend_fetch_dimension_address_RW(&rv, container, dim, IS_TMP_VAR TSRMLS_CC);
                value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
                ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
                var_ptr = Z_INDIRECT(rv);
@@ -29658,7 +24013,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(int (*
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op2;
@@ -29666,7 +24021,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_VAR(int (*bina
        zval *value;
 
        SAVE_OPLINE();
-       value = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+       value = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
        var_ptr = NULL;
 
        if (IS_UNUSED == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
@@ -29675,325 +24030,16 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_VAR(int (*bina
 
        if (IS_UNUSED == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
                if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
-               }
-       } else {
-               ZVAL_DEREF(var_ptr);
-               SEPARATE_ZVAL_NOREF(var_ptr);
-
-               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
-
-               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
-               }
-       }
-
-       zval_ptr_dtor_nogc(free_op2);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_ADD_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_SUB_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_MUL_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_DIV_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_MOD_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_SL_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_SR_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_CONCAT_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_OR_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_AND_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_VAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
-       zval *object;
-       zval *property;
-       zval *retval;
-       zval *zptr;
-
-       SAVE_OPLINE();
-       object = _get_obj_zval_ptr_unused(execute_data);
-       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-       retval = EX_VAR(opline->result.var);
-
-       if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
-       }
-
-       if (IS_UNUSED != IS_UNUSED) {
-               object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
-       }
-
-       if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
-               zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-               zval_ptr_dtor_nogc(free_op2);
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(retval);
-               }
-
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
-
-       /* here we are sure we are dealing with an object */
-
-       if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
-
-               ZVAL_DEREF(zptr);
-               SEPARATE_ZVAL_NOREF(zptr);
-
-               incdec_op(zptr);
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_COPY(retval, zptr);
-               }
-       } else {
-               zval rv;
-
-               if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
-                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
-
-                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
-                               zval rv;
-                               zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
-
-                               if (Z_REFCOUNT_P(z) == 0) {
-                                       zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
-                               }
-                               ZVAL_COPY_VALUE(z, value);
-                       }
-                       if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
-                       SEPARATE_ZVAL_IF_NOT_REF(z);
-                       incdec_op(z);
-                       ZVAL_COPY_VALUE(retval, z);
-                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
-                       SELECTIVE_PZVAL_LOCK(retval, opline);
-                       zval_ptr_dtor(z);
-               } else {
-                       zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-                       if (RETURN_VALUE_USED(opline)) {
-                               ZVAL_NULL(retval);
-                       }
-               }
-       }
-
-       zval_ptr_dtor_nogc(free_op2);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_PRE_INC_OBJ_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_pre_incdec_property_helper_SPEC_UNUSED_VAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_pre_incdec_property_helper_SPEC_UNUSED_VAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_VAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
-       zval *object;
-       zval *property;
-       zval *retval;
-       zval *zptr;
-
-       SAVE_OPLINE();
-       object = _get_obj_zval_ptr_unused(execute_data);
-       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-       retval = EX_VAR(opline->result.var);
-
-       if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
-       }
-
-       if (IS_UNUSED != IS_UNUSED) {
-               object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
-       }
-
-       if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
-               zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-               zval_ptr_dtor_nogc(free_op2);
-               ZVAL_NULL(retval);
-
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
-
-       /* here we are sure we are dealing with an object */
-
-       if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
-
-               ZVAL_DEREF(zptr);
-               ZVAL_COPY_VALUE(retval, zptr);
-               zval_opt_copy_ctor(zptr);
-
-               incdec_op(zptr);
-       } else {
-               if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
-                       zval rv;
-                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
-                       zval z_copy;
-
-                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
-                               zval rv;
-                               zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
-
-                               if (Z_REFCOUNT_P(z) == 0) {
-                                       zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
-                               }
-                               ZVAL_COPY_VALUE(z, value);
-                       }
-                       ZVAL_DUP(retval, z);
-                       ZVAL_DUP(&z_copy, z);
-                       incdec_op(&z_copy);
-                       if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
-                       Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
-                       zval_ptr_dtor(&z_copy);
-                       zval_ptr_dtor(z);
-               } else {
-                       zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-                       ZVAL_NULL(retval);
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
+       } else {
+               ZVAL_DEREF(var_ptr);
+               SEPARATE_ZVAL_NOREF(var_ptr);
+
+               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
+
+               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
                }
        }
 
@@ -30003,246 +24049,371 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_VAR(incdec
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_POST_INC_OBJ_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_ADD_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_post_incdec_property_helper_SPEC_UNUSED_VAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
 }
 
-static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_SUB_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_post_incdec_property_helper_SPEC_UNUSED_VAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_MUL_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *container;
-       zend_free_op free_op2;
-       zval *offset;
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
 
-       SAVE_OPLINE();
-       container = _get_obj_zval_ptr_unused(execute_data);
-       offset  = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+static int ZEND_FASTCALL  ZEND_ASSIGN_DIV_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       if ((IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
-           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
-               zend_error(E_NOTICE, "Trying to get property of non-object");
-               ZVAL_NULL(EX_VAR(opline->result.var));
-       } else {
-               zval *retval;
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
 
-               /* here we are sure we are dealing with an object */
-               do {
-                       if (IS_VAR == IS_CONST &&
-                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
-                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
-                               zend_object *zobj = Z_OBJ_P(container);
+static int ZEND_FASTCALL  ZEND_ASSIGN_MOD_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-                               if (EXPECTED(prop_info)) {
-                                       retval = OBJ_PROP(zobj, prop_info->offset);
-                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               } else if (EXPECTED(zobj->properties != NULL)) {
-                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
-                                       if (EXPECTED(retval)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               }
-                       }
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
 
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+static int ZEND_FASTCALL  ZEND_ASSIGN_SL_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-                       if (retval != EX_VAR(opline->result.var)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                       }
-               } while (0);
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
+}
 
-       zval_ptr_dtor_nogc(free_op2);
+static int ZEND_FASTCALL  ZEND_ASSIGN_SR_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_CONCAT_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
-       zval *property;
-       zval *container;
-
-       SAVE_OPLINE();
-       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       container = _get_obj_zval_ptr_unused(execute_data);
-       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
+}
 
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
-       if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-       }
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_OR_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_AND_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
-       zval *property;
-       zval *container;
-
-       SAVE_OPLINE();
-       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-       container = _get_obj_zval_ptr_unused(execute_data);
 
-       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
-       }
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
-       if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
+}
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_YIELD_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *container;
-       zend_free_op free_op2;
-       zval *offset;
+       /* The generator object is stored in EX(return_value) */
+       zend_generator *generator = (zend_generator *) EX(return_value);
 
-       SAVE_OPLINE();
-       container = _get_obj_zval_ptr_unused(execute_data);
-       offset  = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+       if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
+               zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
+       }
 
-       if ((IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
-           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
-               ZVAL_NULL(EX_VAR(opline->result.var));
-       } else {
-               zval *retval;
+       /* Destroy the previously yielded value */
+       zval_ptr_dtor(&generator->value);
 
-               /* here we are sure we are dealing with an object */
-               do {
-                       if (IS_VAR == IS_CONST &&
-                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
-                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
-                               zend_object *zobj = Z_OBJ_P(container);
+       /* Destroy the previously yielded key */
+       zval_ptr_dtor(&generator->key);
 
-                               if (EXPECTED(prop_info)) {
-                                       retval = OBJ_PROP(zobj, prop_info->offset);
-                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               } else if (EXPECTED(zobj->properties != NULL)) {
-                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
-                                       if (EXPECTED(retval)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
+       /* Set the new yielded value */
+       if (IS_UNUSED != IS_UNUSED) {
+
+
+               if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
+                       /* Constants and temporary variables aren't yieldable by reference,
+                        * but we still allow them with a notice. */
+                       if (IS_UNUSED == IS_CONST || IS_UNUSED == IS_TMP_VAR) {
+                               zval *value;
+
+                               zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+
+                               value = NULL;
+                               ZVAL_COPY_VALUE(&generator->value, value);
+                               if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
+
+                               /* Temporary variables don't need ctor copying */
+                               if (IS_UNUSED != IS_TMP_VAR) {
+                                       zval_opt_copy_ctor(&generator->value);
                                }
-                       }
+                       } else {
+                               zval *value_ptr = NULL;
 
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+                               if (IS_UNUSED == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+                                       zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
+                               }
 
-                       if (retval != EX_VAR(opline->result.var)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                       }
-               } while (0);
-       }
+                               /* If a function call result is yielded and the function did
+                                * not return by reference we throw a notice. */
+                               if (IS_UNUSED == IS_VAR &&
+                                   (value_ptr == &EG(uninitialized_zval) ||
+                                    (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+                                     !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+                                       zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+                               } else {
+                                       ZVAL_MAKE_REF(value_ptr);
+                               }
+                               ZVAL_COPY(&generator->value, value_ptr);
 
-       zval_ptr_dtor_nogc(free_op2);
+                       }
+               } else {
+                       zval *value = NULL;
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+                       /* Consts, temporary variables and references need copying */
+                       if (IS_UNUSED == IS_CONST) {
+                               ZVAL_DUP(&generator->value, value);
+                       } else if (IS_UNUSED == IS_TMP_VAR) {
+                               ZVAL_COPY_VALUE(&generator->value, value);
+            } else if ((IS_UNUSED == IS_CV || IS_UNUSED == IS_VAR) && Z_ISREF_P(value)) {
+                               ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *container;
+                       } else {
+                               ZVAL_COPY_VALUE(&generator->value, value);
+                               if (IS_UNUSED == IS_CV) {
+                                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+                               }
+                       }
+               }
+       } else {
+               /* If no value was specified yield null */
+               ZVAL_NULL(&generator->value);
+       }
 
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-               /* Behave like FETCH_OBJ_W */
-               zend_free_op free_op1, free_op2;
-               zval *property;
+       /* Set the new yielded key */
+       if (IS_TMP_VAR != IS_UNUSED) {
+               zend_free_op free_op2;
+               zval *key = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
 
-               SAVE_OPLINE();
-               property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-               container = _get_obj_zval_ptr_unused(execute_data);
+               /* Consts, temporary variables and references need copying */
+               if (IS_TMP_VAR == IS_CONST) {
+                       ZVAL_DUP(&generator->key, key);
+               } else if (IS_TMP_VAR == IS_TMP_VAR) {
+                       ZVAL_COPY_VALUE(&generator->key, key);
+               } else if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && Z_ISREF_P(key)) {
+                       ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
 
-        if (IS_UNUSED == IS_CONST || IS_UNUSED == IS_TMP_VAR) {
-            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
-        }
-               if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+               } else {
+                       ZVAL_COPY_VALUE(&generator->key, key);
+                       if (IS_TMP_VAR == IS_CV) {
+                               if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
+                       }
                }
-               zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op2);
-               if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
-                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+
+               if (Z_TYPE(generator->key) == IS_LONG
+                   && Z_LVAL(generator->key) > generator->largest_used_integer_key
+               ) {
+                       generator->largest_used_integer_key = Z_LVAL(generator->key);
                }
+       } else {
+               /* If no key was specified we use auto-increment keys */
+               generator->largest_used_integer_key++;
+               ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
+       }
 
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
+       if (RETURN_VALUE_USED(opline)) {
+               /* If the return value of yield is used set the send
+                * target and initialize it to NULL */
+               generator->send_target = EX_VAR(opline->result.var);
+               ZVAL_NULL(generator->send_target);
        } else {
-               return ZEND_FETCH_OBJ_R_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               generator->send_target = NULL;
        }
+
+       /* We increment to the next op, so we are at the correct position when the
+        * generator is resumed. */
+       ZEND_VM_INC_OPCODE();
+
+       /* The GOTO VM uses a local opline variable. We need to set the opline
+        * variable in execute_data so we don't resume at an old position. */
+       SAVE_OPLINE();
+
+       ZEND_VM_RETURN();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_POW_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       USE_OPLINE
-       zend_free_op free_op1, free_op2;
-       zval *container, *property;
+       return zend_binary_assign_op_helper_SPEC_UNUSED_TMP(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
 
-       SAVE_OPLINE();
-       container = _get_obj_zval_ptr_unused(execute_data);
-       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op2, free_op_data1;
+       zval *object = _get_obj_zval_ptr_unused(execute_data);
+       zval *property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+       zval *value;
+       zval *zptr;
 
-       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
-       if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+
+       if (IS_UNUSED != IS_UNUSED) {
+               object = make_real_object(object TSRMLS_CC);
        }
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
-       zval *object;
-       zval *property_name;
+       if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+               zend_error(E_WARNING, "Attempt to assign property of non-object");
+               zval_ptr_dtor_nogc(free_op2);
+               FREE_OP(free_op_data1);
 
-       SAVE_OPLINE();
-       object = _get_obj_zval_ptr_unused(execute_data);
-       property_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
+       } else {
+               /* here we are sure we are dealing with an object */
+               if (opline->extended_value == ZEND_ASSIGN_OBJ
+                       && EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+                       && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
 
-       if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+                       ZVAL_DEREF(zptr);
+                       SEPARATE_ZVAL_NOREF(zptr);
+
+                       binary_op(zptr, zptr, value TSRMLS_CC);
+                       if (RETURN_VALUE_USED(opline)) {
+                               ZVAL_COPY(EX_VAR(opline->result.var), zptr);
+                       }
+               } else {
+                       zval *z = NULL;
+                       zval rv;
+
+                       if (opline->extended_value == ZEND_ASSIGN_OBJ) {
+                               if (Z_OBJ_HT_P(object)->read_property) {
+                                       z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+                               }
+                       } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
+                               if (Z_OBJ_HT_P(object)->read_dimension) {
+                                       z = Z_OBJ_HT_P(object)->read_dimension(object, property, BP_VAR_R, &rv TSRMLS_CC);
+                               }
+                       }
+                       if (z) {
+                               if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                                       zval rv;
+                                       zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+
+                                       if (Z_REFCOUNT_P(z) == 0) {
+                                               zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
+                                       }
+                                       ZVAL_COPY_VALUE(z, value);
+                               }
+//???                          if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
+                               SEPARATE_ZVAL_IF_NOT_REF(z);
+                               binary_op(z, z, value TSRMLS_CC);
+                               if (opline->extended_value == ZEND_ASSIGN_OBJ) {
+                                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+                               } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
+                                       Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
+                               }
+                               if (RETURN_VALUE_USED(opline)) {
+                                       ZVAL_COPY(EX_VAR(opline->result.var), z);
+                               }
+                               zval_ptr_dtor(z);
+                       } else {
+                               zend_error(E_WARNING, "Attempt to assign property of non-object");
+                               if (RETURN_VALUE_USED(opline)) {
+                                       ZVAL_NULL(EX_VAR(opline->result.var));
+                               }
+                       }
+               }
+
+               zval_ptr_dtor_nogc(free_op2);
+               FREE_OP(free_op_data1);
        }
-       zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_UNUSED, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
 
        /* assign_obj has two opcodes! */
        CHECK_EXCEPTION();
@@ -30250,450 +24421,239 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HA
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ADD_VAR_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
-       zval *str = EX_VAR(opline->result.var);
-       zval *var;
-       zval var_copy;
-       int use_copy = 0;
+       zend_free_op free_op2, free_op_data1;
+       zval *var_ptr, rv;
+       zval *value, *container;
 
        SAVE_OPLINE();
-       var = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
-       if (IS_UNUSED == IS_UNUSED) {
-               /* Initialize for erealloc in add_string_to_string */
-               ZVAL_EMPTY_STRING(str);
+       container = _get_obj_zval_ptr_unused(execute_data);
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-
-       if (Z_TYPE_P(var) != IS_STRING) {
-               if (IS_VAR != IS_TMP_VAR) {
-                       ZVAL_DEREF(var);
+       if (IS_UNUSED != IS_UNUSED) {
+               ZVAL_DEREF(container);
+       }
+       if (IS_UNUSED == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+               if (IS_UNUSED == IS_VAR && !0) {
+                       Z_ADDREF_P(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
                }
-               if (Z_TYPE_P(var) != IS_STRING) {
-                       use_copy = zend_make_printable_zval(var, &var_copy TSRMLS_CC);
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else {
+               zval *dim = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
 
-                       if (use_copy) {
-                               var = &var_copy;
-                       }
-               }
+               zend_fetch_dimension_address_RW(&rv, container, dim, IS_VAR TSRMLS_CC);
+               value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+               ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+               var_ptr = Z_INDIRECT(rv);
        }
-       add_string_to_string(str, str, var);
 
-       if (use_copy) {
-               zend_string_release(Z_STR_P(var));
+       if (UNEXPECTED(var_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
        }
-       /* original comment, possibly problematic:
-        * FREE_OP is missing intentionally here - we're always working on the same temporary variable
-        * (Zeev):  I don't think it's problematic, we only use variables
-        * which aren't affected by FREE_OP(Ts, )'s anyway, unless they're
-        * string offsets or overloaded objects
-        */
+
+       if (UNEXPECTED(var_ptr == &EG(error_zval))) {
+               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
+       } else {
+               ZVAL_DEREF(var_ptr);
+               SEPARATE_ZVAL_NOREF(var_ptr);
+
+               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
+
+               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+               }
+       }
+
        zval_ptr_dtor_nogc(free_op2);
+       FREE_OP(free_op_data1);
 
        CHECK_EXCEPTION();
+       ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *function_name;
        zend_free_op free_op2;
-       zval *object;
-       zend_function *fbc;
-       zend_class_entry *called_scope;
-       zend_object *obj;
+       zval *var_ptr;
+       zval *value;
 
        SAVE_OPLINE();
+       value = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+       var_ptr = NULL;
 
-       function_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
-       if (IS_VAR != IS_CONST &&
-           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       HANDLE_EXCEPTION();
-               }
-               zend_error_noreturn(E_ERROR, "Method name must be a string");
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
        }
 
-       object = _get_obj_zval_ptr_unused(execute_data);
-
-       if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
-               uint32_t nesting = 1;
-
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       zval_ptr_dtor_nogc(free_op2);
-                       HANDLE_EXCEPTION();
-               }
-
-               zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s",  Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
-               zval_ptr_dtor_nogc(free_op2);
-
-               if (EG(exception) != NULL) {
-                       HANDLE_EXCEPTION();
-               }
-
-               /* No exception raised: Skip over arguments until fcall opcode with correct
-                * nesting level. Return NULL (except when return value unused) */
-               do {
-                       opline++;
-                       if (opline->opcode == ZEND_INIT_FCALL ||
-                               opline->opcode == ZEND_INIT_FCALL_BY_NAME ||
-                               opline->opcode == ZEND_INIT_NS_FCALL_BY_NAME ||
-                               opline->opcode == ZEND_INIT_METHOD_CALL ||
-                               opline->opcode == ZEND_INIT_STATIC_METHOD_CALL ||
-                               opline->opcode == ZEND_INIT_USER_CALL ||
-                               opline->opcode == ZEND_NEW
-                       ) {
-                               nesting++;
-                       } else if (opline->opcode == ZEND_DO_FCALL) {
-                               nesting--;
-                       }
-               } while (nesting);
-
-               if (RETURN_VALUE_USED(opline)) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
                        ZVAL_NULL(EX_VAR(opline->result.var));
                }
+       } else {
+               ZVAL_DEREF(var_ptr);
+               SEPARATE_ZVAL_NOREF(var_ptr);
 
-               /* We've skipped EXT_FCALL_BEGIND, so also skip the ending opcode */
-               if ((opline + 1)->opcode == ZEND_EXT_FCALL_END) {
-                       opline++;
-               }
-               ZEND_VM_JMP(++opline);
-       }
-
-       obj = Z_OBJ_P(object);
-       called_scope = obj->ce;
-
-       if (IS_VAR != IS_CONST ||
-           EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
-           zend_object *orig_obj = obj;
-
-               if (UNEXPECTED(obj->handlers->get_method == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Object does not support method calls");
-               }
+               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
 
-               /* First, locate the function. */
-               fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_VAR == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
-               if (UNEXPECTED(fbc == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
-               }
-               if (IS_VAR == IS_CONST &&
-                   EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
-                   EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
-                   EXPECTED(obj == orig_obj)) {
-                       CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope, fbc);
+               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
                }
        }
 
-       if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_STATIC) != 0)) {
-               obj = NULL;
-       } else {
-               GC_REFCOUNT(obj)++; /* For $this pointer */
-       }
-
-       EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
-               fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
-
        zval_ptr_dtor_nogc(free_op2);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_ADD_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zval *array;
-       uint32_t size;
        USE_OPLINE
 
-       array = EX_VAR(opline->result.var);
-       if (IS_UNUSED != IS_UNUSED) {
-               size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
-       } else {
-               size = 0;
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
-       ZVAL_NEW_ARR(array);
-       zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
+}
 
-       if (IS_UNUSED != IS_UNUSED) {
-               /* Explicitly initialize array as not-packed if flag is set */
-               if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
-                       zend_hash_real_init(Z_ARRVAL_P(array), 0);
-               }
-       }
+static int ZEND_FASTCALL  ZEND_ASSIGN_SUB_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       if (IS_UNUSED == IS_UNUSED) {
-               ZEND_VM_NEXT_OPCODE();
-#if 0 || IS_UNUSED != IS_UNUSED
-       } else {
-               return ZEND_ADD_ARRAY_ELEMENT_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-#endif
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_MUL_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
-       zval *container;
-       zval *offset;
-       zend_ulong hval;
-
-       SAVE_OPLINE();
-       container = _get_obj_zval_ptr_unused(execute_data);
-       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
-       }
-       if (IS_UNUSED != IS_UNUSED) {
-               ZVAL_DEREF(container);
-       }
-       SEPARATE_ZVAL_NOREF(container);
-       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if (IS_UNUSED != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
-               HashTable *ht = Z_ARRVAL_P(container);
-offset_again:
-               switch (Z_TYPE_P(offset)) {
-                       case IS_DOUBLE:
-                               hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                               zend_hash_index_del(ht, hval);
-                               break;
-                       case IS_LONG:
-                               hval = Z_LVAL_P(offset);
-num_index_dim:
-                               zend_hash_index_del(ht, hval);
-                               break;
-                       case IS_STRING:
-                               if (IS_VAR != IS_CONST) {
-                                       if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
-                                               goto num_index_dim;
-                                       }
-                               }
-                               if (ht == &EG(symbol_table).ht) {
-                                       zend_delete_global_variable(Z_STR_P(offset) TSRMLS_CC);
-                               } else {
-                                       zend_hash_del(ht, Z_STR_P(offset));
-                               }
-                               break;
-                       case IS_NULL:
-                               zend_hash_del(ht, STR_EMPTY_ALLOC());
-                               break;
-                       case IS_FALSE:
-                               hval = 0;
-                               goto num_index_dim;
-                       case IS_TRUE:
-                               hval = 1;
-                               goto num_index_dim;
-                       case IS_RESOURCE:
-                               hval = Z_RES_HANDLE_P(offset);
-                               goto num_index_dim;
-                       case IS_REFERENCE:
-                               offset = Z_REFVAL_P(offset);
-                               goto offset_again;
-                               break;
-                       default:
-                               zend_error(E_WARNING, "Illegal offset type in unset");
-                               break;
-               }
-               zval_ptr_dtor_nogc(free_op2);
-       } else if (IS_UNUSED == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use object as array");
-               }
-//???          if (IS_VAR == IS_CONST) {
-//???                  zval_copy_ctor(offset);
-//???          }
-               Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op2);
-       } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
-               ZEND_VM_CONTINUE(); /* bailed out before */
-       } else {
-               zval_ptr_dtor_nogc(free_op2);
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_DIV_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
-       zval *container;
-       zval *offset;
 
-       SAVE_OPLINE();
-       container = _get_obj_zval_ptr_unused(execute_data);
-       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
-       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+}
 
-       if (IS_UNUSED != IS_UNUSED) {
-               ZVAL_DEREF(container);
-       }
-       if (IS_UNUSED == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
-               if (Z_OBJ_HT_P(container)->unset_property) {
-                       Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
-               } else {
-                       zend_error(E_NOTICE, "Trying to unset property of non-object");
-               }
-       }
-       zval_ptr_dtor_nogc(free_op2);
+static int ZEND_FASTCALL  ZEND_ASSIGN_MOD_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_SL_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
-       zval *container;
-       int result;
-       zend_ulong hval;
-       zval *offset;
 
-       SAVE_OPLINE();
-       container = _get_obj_zval_ptr_unused(execute_data);
-       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
 
-       if (IS_UNUSED != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
-               HashTable *ht = Z_ARRVAL_P(container);
-               zval *value;
-               zend_string *str;
+static int ZEND_FASTCALL  ZEND_ASSIGN_SR_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-isset_again:
-               if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
-                       str = Z_STR_P(offset);
-                       if (IS_VAR != IS_CONST) {
-                               if (ZEND_HANDLE_NUMERIC(str, hval)) {
-                                       goto num_index_prop;
-                               }
-                       }
-str_index_prop:
-                       value = zend_hash_find_ind(ht, str);
-               } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
-                       hval = Z_LVAL_P(offset);
-num_index_prop:
-                       value = zend_hash_index_find(ht, hval);
-               } else {
-                       switch (Z_TYPE_P(offset)) {
-                               case IS_DOUBLE:
-                                       hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                                       goto num_index_prop;
-                               case IS_NULL:
-                                       str = STR_EMPTY_ALLOC();
-                                       goto str_index_prop;
-                               case IS_FALSE:
-                                       hval = 0;
-                                       goto num_index_prop;
-                               case IS_TRUE:
-                                       hval = 1;
-                                       goto num_index_prop;
-                               case IS_RESOURCE:
-                                       hval = Z_RES_HANDLE_P(offset);
-                                       goto num_index_prop;
-                               case IS_REFERENCE:
-                                       offset = Z_REFVAL_P(offset);
-                                       goto isset_again;
-                               default:
-                                       zend_error(E_WARNING, "Illegal offset type in isset or empty");
-                                       value = NULL;
-                                       break;
-                       }
-               }
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
 
-               if (opline->extended_value & ZEND_ISSET) {
-                       /* > IS_NULL means not IS_UNDEF and not IS_NULL */
-                       result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
-               }
-       } else if (IS_UNUSED == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
-                       result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
-               } else {
-                       zend_error(E_NOTICE, "Trying to check element of non-array");
-                       result = 0;
-               }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
-               }
-       } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
-               zval tmp;
+static int ZEND_FASTCALL  ZEND_ASSIGN_CONCAT_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-               result = 0;
-               if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
-                       if (IS_VAR == IS_CV || IS_VAR == IS_VAR) {
-                               ZVAL_DEREF(offset);
-                       }
-                       if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
-                                       || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
-                                               && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
-                               ZVAL_DUP(&tmp, offset);
-                               convert_to_long(&tmp);
-                               offset = &tmp;
-                       }
-               }
-               if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
-                       if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
-                               if ((opline->extended_value & ZEND_ISSET) ||
-                                   Z_STRVAL_P(container)[offset->value.lval] != '0') {
-                                       result = 1;
-                               }
-                       }
-               }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
-               }
-       } else {
-               result = ((opline->extended_value & ZEND_ISSET) == 0);
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
+}
 
-       zval_ptr_dtor_nogc(free_op2);
-       ZVAL_BOOL(EX_VAR(opline->result.var), result);
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_OR_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_AND_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
-       zval *container;
-       int result;
-       zval *offset;
-
-       SAVE_OPLINE();
-       container = _get_obj_zval_ptr_unused(execute_data);
-       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if (IS_UNUSED == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
-                       result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
-               } else {
-                       zend_error(E_NOTICE, "Trying to check property of non-object");
-                       result = 0;
-               }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
-               }
-       } else {
-               result = ((opline->extended_value & ZEND_ISSET) == 0);
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
+}
 
-       zval_ptr_dtor_nogc(free_op2);
-       ZVAL_BOOL(EX_VAR(opline->result.var), result);
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_UNUSED_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_UNUSED_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
 }
 
 static int ZEND_FASTCALL  ZEND_YIELD_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
@@ -32076,15 +26036,10 @@ static int ZEND_FASTCALL  ZEND_ADD_VAR_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLE
        }
 
        if (Z_TYPE_P(var) != IS_STRING) {
-               if (IS_CV != IS_TMP_VAR) {
-                       ZVAL_DEREF(var);
-               }
-               if (Z_TYPE_P(var) != IS_STRING) {
-                       use_copy = zend_make_printable_zval(var, &var_copy TSRMLS_CC);
+               use_copy = zend_make_printable_zval(var, &var_copy TSRMLS_CC);
 
-                       if (use_copy) {
-                               var = &var_copy;
-                       }
+               if (use_copy) {
+                       var = &var_copy;
                }
        }
        add_string_to_string(str, str, var);
@@ -32436,7 +26391,7 @@ num_index_prop:
 
                result = 0;
                if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
-                       if (IS_CV == IS_CV || IS_CV == IS_VAR) {
+                       if (IS_CV & (IS_CV|IS_VAR)) {
                                ZVAL_DEREF(offset);
                        }
                        if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
@@ -32633,2482 +26588,2682 @@ static int ZEND_FASTCALL  ZEND_YIELD_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_POW_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_binary_assign_op_helper_SPEC_UNUSED_CV(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_BW_NOT_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-
-       SAVE_OPLINE();
-       bitwise_not_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC) TSRMLS_CC);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_BOOL_NOT_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-
-       SAVE_OPLINE();
-       boolean_not_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC) TSRMLS_CC);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_PRE_INC_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       zval *var_ptr;
-
-       SAVE_OPLINE();
-       var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
-
-       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
-       }
-
-       if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
-               fast_increment_function(var_ptr);
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
-               }
-               ZEND_VM_NEXT_OPCODE();
-       }
-
-       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
-               }
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
-
-       ZVAL_DEREF(var_ptr);
-       SEPARATE_ZVAL_NOREF(var_ptr);
-
-       increment_function(var_ptr);
-
-       if (RETURN_VALUE_USED(opline)) {
-               ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
-       }
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       return zend_binary_assign_op_helper_SPEC_UNUSED_CV(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_PRE_DEC_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_TMPVAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
-       zval *var_ptr;
+       zend_free_op free_op2;
+       zval *object;
+       zval *property;
+       zval *retval;
+       zval *zptr;
 
        SAVE_OPLINE();
-       var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+       object = _get_obj_zval_ptr_unused(execute_data);
+       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+       retval = EX_VAR(opline->result.var);
 
-       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
-       if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
-               fast_decrement_function(var_ptr);
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
-               }
-               ZEND_VM_NEXT_OPCODE();
+       if (IS_UNUSED != IS_UNUSED) {
+               object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
        }
 
-       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+       if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+               zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+               zval_ptr_dtor_nogc(free_op2);
                if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
+                       ZVAL_NULL(retval);
                }
+
                CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
-       ZVAL_DEREF(var_ptr);
-       SEPARATE_ZVAL_NOREF(var_ptr);
-
-       decrement_function(var_ptr);
-
-       if (RETURN_VALUE_USED(opline)) {
-               ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
-       }
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+       /* here we are sure we are dealing with an object */
 
-static int ZEND_FASTCALL  ZEND_POST_INC_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
 
-       zval *var_ptr;
+               ZVAL_DEREF(zptr);
+               SEPARATE_ZVAL_NOREF(zptr);
 
-       SAVE_OPLINE();
-       var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+               incdec_op(zptr);
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_COPY(retval, zptr);
+               }
+       } else {
+               zval rv;
 
-       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
-       }
+               if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
+                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
 
-       if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
-               ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
-               fast_increment_function(var_ptr);
-               ZEND_VM_NEXT_OPCODE();
-       }
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
+                               zval rv;
+                               zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
-               ZVAL_NULL(EX_VAR(opline->result.var));
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
+                               if (Z_REFCOUNT_P(z) == 0) {
+                                       zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
+                               }
+                               ZVAL_COPY_VALUE(z, value);
+                       }
+                       if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
+                       SEPARATE_ZVAL_IF_NOT_REF(z);
+                       incdec_op(z);
+                       ZVAL_COPY_VALUE(retval, z);
+                       Z_OBJ_HT_P(object)->write_property(object, property, z, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+                       SELECTIVE_PZVAL_LOCK(retval, opline);
+                       zval_ptr_dtor(z);
+               } else {
+                       zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+                       if (RETURN_VALUE_USED(opline)) {
+                               ZVAL_NULL(retval);
+                       }
+               }
        }
 
-       ZVAL_DEREF(var_ptr);
-       ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
-       zval_opt_copy_ctor(var_ptr);
-
-       increment_function(var_ptr);
+       zval_ptr_dtor_nogc(free_op2);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_POST_DEC_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_PRE_INC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       USE_OPLINE
+       return zend_pre_incdec_property_helper_SPEC_UNUSED_TMPVAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
 
-       zval *var_ptr;
+static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_pre_incdec_property_helper_SPEC_UNUSED_TMPVAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_TMPVAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op2;
+       zval *object;
+       zval *property;
+       zval *retval;
+       zval *zptr;
 
        SAVE_OPLINE();
-       var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+       object = _get_obj_zval_ptr_unused(execute_data);
+       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+       retval = EX_VAR(opline->result.var);
 
-       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
-       if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
-               ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
-               fast_decrement_function(var_ptr);
-               ZEND_VM_NEXT_OPCODE();
+       if (IS_UNUSED != IS_UNUSED) {
+               object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
        }
 
-       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
-               ZVAL_NULL(EX_VAR(opline->result.var));
+       if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+               zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+               zval_ptr_dtor_nogc(free_op2);
+               ZVAL_NULL(retval);
+
                CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
-       ZVAL_DEREF(var_ptr);
-       ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
-       zval_opt_copy_ctor(var_ptr);
+       /* here we are sure we are dealing with an object */
 
-       decrement_function(var_ptr);
+       if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+               ZVAL_DEREF(zptr);
+               ZVAL_COPY_VALUE(retval, zptr);
+               zval_opt_copy_ctor(zptr);
 
-static int ZEND_FASTCALL  ZEND_ECHO_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+               incdec_op(zptr);
+       } else {
+               if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
+                       zval rv;
+                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+                       zval z_copy;
 
-       zval *z;
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
+                               zval rv;
+                               zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
 
-       SAVE_OPLINE();
-       z = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+                               if (Z_REFCOUNT_P(z) == 0) {
+                                       zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
+                               }
+                               ZVAL_COPY_VALUE(z, value);
+                       }
+                       ZVAL_DUP(retval, z);
+                       ZVAL_DUP(&z_copy, z);
+                       incdec_op(&z_copy);
+                       if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
+                       Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+                       zval_ptr_dtor(&z_copy);
+                       zval_ptr_dtor(z);
+               } else {
+                       zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+                       ZVAL_NULL(retval);
+               }
+       }
 
-       zend_print_variable(z TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_PRINT_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_POST_INC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       USE_OPLINE
+       return zend_post_incdec_property_helper_SPEC_UNUSED_TMPVAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
 
-       ZVAL_LONG(EX_VAR(opline->result.var), 1);
-       return ZEND_ECHO_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_post_incdec_property_helper_SPEC_UNUSED_TMPVAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_JMPZ_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *val;
+       zval *container;
+       zend_free_op free_op2;
+       zval *offset;
 
        SAVE_OPLINE();
-       val = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-
-       if (IS_CV == IS_TMP_VAR) {
-               if (Z_TYPE_P(val) == IS_TRUE) {
-                       ZEND_VM_SET_OPCODE(opline + 1);
-                       ZEND_VM_CONTINUE();
-               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
-                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
-                       ZEND_VM_CONTINUE();
-               }
-       }
+       container = _get_obj_zval_ptr_unused(execute_data);
+       offset  = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if (i_zend_is_true(val TSRMLS_CC)) {
-               opline++;
+       if ((IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               zend_error(E_NOTICE, "Trying to get property of non-object");
+               ZVAL_NULL(EX_VAR(opline->result.var));
        } else {
-               opline = opline->op2.jmp_addr;
-       }
+               zval *retval;
 
-       if (UNEXPECTED(EG(exception) != NULL)) {
-               HANDLE_EXCEPTION();
+               /* here we are sure we are dealing with an object */
+               do {
+                       if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
+                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
+                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
+                               zend_object *zobj = Z_OBJ_P(container);
+
+                               if (EXPECTED(prop_info)) {
+                                       retval = OBJ_PROP(zobj, prop_info->offset);
+                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
+                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                                               break;
+                                       }
+                               } else if (EXPECTED(zobj->properties != NULL)) {
+                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
+                                       if (EXPECTED(retval)) {
+                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                                               break;
+                                       }
+                               }
+                       }
+
+                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+
+                       if (retval != EX_VAR(opline->result.var)) {
+                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                       }
+               } while (0);
        }
-       ZEND_VM_JMP(opline);
+
+       zval_ptr_dtor_nogc(free_op2);
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_JMPNZ_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
-       zval *val;
+       zend_free_op free_op1, free_op2;
+       zval *property;
+       zval *container;
 
        SAVE_OPLINE();
-       val = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if (IS_CV == IS_TMP_VAR) {
-               if (Z_TYPE_P(val) == IS_TRUE) {
-                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
-                       ZEND_VM_CONTINUE();
-               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
-                       ZEND_VM_SET_OPCODE(opline + 1);
-                       ZEND_VM_CONTINUE();
-               }
+       container = _get_obj_zval_ptr_unused(execute_data);
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
 
-       if (i_zend_is_true(val TSRMLS_CC)) {
-               opline = opline->op2.jmp_addr;
-       } else {
-               opline++;
+       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
+       if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
 
-       if (UNEXPECTED(EG(exception) != NULL)) {
-               HANDLE_EXCEPTION();
-       }
-       ZEND_VM_JMP(opline);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_JMPZNZ_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
-       zval *val;
+       zend_free_op free_op1, free_op2;
+       zval *property;
+       zval *container;
 
        SAVE_OPLINE();
-       val = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+       container = _get_obj_zval_ptr_unused(execute_data);
 
-       if (IS_CV == IS_TMP_VAR) {
-               if (EXPECTED(Z_TYPE_P(val) == IS_TRUE)) {
-                       ZEND_VM_SET_RELATIVE_OPCODE(opline, opline->extended_value);
-                       ZEND_VM_CONTINUE();
-               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
-                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
-                       ZEND_VM_CONTINUE();
-               }
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
-
-       if (i_zend_is_true(val TSRMLS_CC)) {
-               opline = (zend_op*)(((char*)opline) + opline->extended_value);
-       } else {
-               opline = opline->op2.jmp_addr;
+       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
+       if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
 
-       if (UNEXPECTED(EG(exception) != NULL)) {
-               HANDLE_EXCEPTION();
-       }
-       ZEND_VM_JMP(opline);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_JMPZ_EX_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *val;
+       zval *container;
+       zend_free_op free_op2;
+       zval *offset;
 
        SAVE_OPLINE();
-       val = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+       container = _get_obj_zval_ptr_unused(execute_data);
+       offset  = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if (IS_CV == IS_TMP_VAR) {
-               if (Z_TYPE_P(val) == IS_TRUE) {
-                       ZVAL_TRUE(EX_VAR(opline->result.var));
-                       ZEND_VM_SET_OPCODE(opline + 1);
-                       ZEND_VM_CONTINUE();
-               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
-                       ZVAL_FALSE(EX_VAR(opline->result.var));
-                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
-                       ZEND_VM_CONTINUE();
-               }
-       }
+       if ((IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               ZVAL_NULL(EX_VAR(opline->result.var));
+       } else {
+               zval *retval;
 
-       if (i_zend_is_true(val TSRMLS_CC)) {
+               /* here we are sure we are dealing with an object */
+               do {
+                       if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
+                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
+                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
+                               zend_object *zobj = Z_OBJ_P(container);
 
-               ZVAL_TRUE(EX_VAR(opline->result.var));
-               opline++;
-       } else {
+                               if (EXPECTED(prop_info)) {
+                                       retval = OBJ_PROP(zobj, prop_info->offset);
+                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
+                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                                               break;
+                                       }
+                               } else if (EXPECTED(zobj->properties != NULL)) {
+                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
+                                       if (EXPECTED(retval)) {
+                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                                               break;
+                                       }
+                               }
+                       }
 
-               ZVAL_FALSE(EX_VAR(opline->result.var));
-               opline = opline->op2.jmp_addr;
-       }
-       if (UNEXPECTED(EG(exception) != NULL)) {
-               HANDLE_EXCEPTION();
+                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+
+                       if (retval != EX_VAR(opline->result.var)) {
+                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                       }
+               } while (0);
        }
-       ZEND_VM_JMP(opline);
+
+       zval_ptr_dtor_nogc(free_op2);
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_JMPNZ_EX_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zval *container;
 
-       zval *val;
+       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+               /* Behave like FETCH_OBJ_W */
+               zend_free_op free_op1, free_op2;
+               zval *property;
 
-       SAVE_OPLINE();
-       val = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+               SAVE_OPLINE();
+               property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+               container = _get_obj_zval_ptr_unused(execute_data);
 
-       if (IS_CV == IS_TMP_VAR) {
-               if (Z_TYPE_P(val) == IS_TRUE) {
-                       ZVAL_TRUE(EX_VAR(opline->result.var));
-                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
-                       ZEND_VM_CONTINUE();
-               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
-                       ZVAL_FALSE(EX_VAR(opline->result.var));
-                       ZEND_VM_SET_OPCODE(opline + 1);
-                       ZEND_VM_CONTINUE();
+        if (IS_UNUSED == IS_CONST || IS_UNUSED == IS_TMP_VAR) {
+            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+        }
+               if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+               }
+               zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+               zval_ptr_dtor_nogc(free_op2);
+               if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
+                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
                }
-       }
-       if (i_zend_is_true(val TSRMLS_CC)) {
-               ZVAL_TRUE(EX_VAR(opline->result.var));
-               opline = opline->op2.jmp_addr;
-       } else {
-               ZVAL_FALSE(EX_VAR(opline->result.var));
-               opline++;
-       }
 
-       if (UNEXPECTED(EG(exception) != NULL)) {
-               HANDLE_EXCEPTION();
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
+       } else {
+               return ZEND_FETCH_OBJ_R_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
-       ZEND_VM_JMP(opline);
 }
 
-static int ZEND_FASTCALL  ZEND_RETURN_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *retval_ptr;
-
+       zend_free_op free_op1, free_op2;
+       zval *container, *property;
 
        SAVE_OPLINE();
-       retval_ptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-
-       if (!EX(return_value)) {
-
-       } else {
-               if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
-                       ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
-                       if (IS_CV == IS_CONST) {
-                               if (UNEXPECTED(Z_OPT_COPYABLE_P(EX(return_value)))) {
-                                       zval_copy_ctor_func(EX(return_value));
-                               }
-                       }
-               } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(retval_ptr)) {
-                       ZVAL_COPY(EX(return_value), Z_REFVAL_P(retval_ptr));
+       container = _get_obj_zval_ptr_unused(execute_data);
+       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-               } else {
-                       ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
-                       if (IS_CV == IS_CV) {
-                               if (Z_OPT_REFCOUNTED_P(retval_ptr)) Z_ADDREF_P(retval_ptr);
-                       }
-               }
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
-       return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_UNUSED, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
+       if (IS_UNUSED == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+       }
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_RETURN_BY_REF_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *retval_ptr;
-
+       zend_free_op free_op2;
+       zval *object;
+       zval *property_name;
 
        SAVE_OPLINE();
+       object = _get_obj_zval_ptr_unused(execute_data);
+       property_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       do {
-               if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR ||
-                   (IS_CV == IS_VAR && opline->extended_value == ZEND_RETURNS_VALUE)) {
-                       /* Not supposed to happen, but we'll allow it */
-                       zend_error(E_NOTICE, "Only variable references should be returned by reference");
-
-                       retval_ptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-                       if (!EX(return_value)) {
-                               if (IS_CV == IS_TMP_VAR) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(object == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+       }
+       zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_UNUSED, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
 
-                               }
-                       } else {
-                               ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
-                               Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
-                               if (IS_CV != IS_TMP_VAR) {
-                                       zval_opt_copy_ctor_no_imm(EX(return_value));
-                               }
-                       }
-                       break;
-               }
+       /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
+       ZEND_VM_INC_OPCODE();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-               retval_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+static int ZEND_FASTCALL  ZEND_ADD_VAR_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op2;
+       zval *str = EX_VAR(opline->result.var);
+       zval *var;
+       zval var_copy;
+       int use_copy = 0;
 
-               if (IS_CV == IS_VAR && UNEXPECTED(retval_ptr == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot return string offsets by reference");
-               }
+       SAVE_OPLINE();
+       var = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-               if (IS_CV == IS_VAR) {
-                       if (retval_ptr == &EG(uninitialized_zval) ||
-                           (opline->extended_value == ZEND_RETURNS_FUNCTION &&
-                            !(Z_VAR_FLAGS_P(retval_ptr) & IS_VAR_RET_REF))) {
-                               zend_error(E_NOTICE, "Only variable references should be returned by reference");
-                               if (EX(return_value)) {
-                                       ZVAL_NEW_REF(EX(return_value), retval_ptr);
-                                       Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
-                                       if (Z_REFCOUNTED_P(retval_ptr)) Z_ADDREF_P(retval_ptr);
-                               }
-                               break;
-                       }
-               }
+       if (IS_UNUSED == IS_UNUSED) {
+               /* Initialize for erealloc in add_string_to_string */
+               ZVAL_EMPTY_STRING(str);
+       }
 
-               if (EX(return_value)) {
-                       ZVAL_MAKE_REF(retval_ptr);
-                       Z_ADDREF_P(retval_ptr);
-                       ZVAL_REF(EX(return_value), Z_REF_P(retval_ptr));
-                       Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
+       if (Z_TYPE_P(var) != IS_STRING) {
+               use_copy = zend_make_printable_zval(var, &var_copy TSRMLS_CC);
+
+               if (use_copy) {
+                       var = &var_copy;
                }
-       } while (0);
+       }
+       add_string_to_string(str, str, var);
 
-       return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       if (use_copy) {
+               zend_string_release(Z_STR_P(var));
+       }
+       /* original comment, possibly problematic:
+        * FREE_OP is missing intentionally here - we're always working on the same temporary variable
+        * (Zeev):  I don't think it's problematic, we only use variables
+        * which aren't affected by FREE_OP(Ts, )'s anyway, unless they're
+        * string offsets or overloaded objects
+        */
+       zval_ptr_dtor_nogc(free_op2);
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_THROW_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *value;
-
+       zval *function_name;
+       zend_free_op free_op2;
+       zval *object;
+       zend_function *fbc;
+       zend_class_entry *called_scope;
+       zend_object *obj;
 
        SAVE_OPLINE();
-       value = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_CONST || UNEXPECTED(Z_TYPE_P(value) != IS_OBJECT)) {
+       function_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+
+       if ((IS_TMP_VAR|IS_VAR) != IS_CONST &&
+           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                if (UNEXPECTED(EG(exception) != NULL)) {
                        HANDLE_EXCEPTION();
                }
-               zend_error_noreturn(E_ERROR, "Can only throw objects");
+               zend_error_noreturn(E_ERROR, "Method name must be a string");
        }
 
-       zend_exception_save(TSRMLS_C);
-       if (IS_CV != IS_TMP_VAR) {
-               if (Z_REFCOUNTED_P(value)) Z_ADDREF_P(value);
-       }
+       object = _get_obj_zval_ptr_unused(execute_data);
 
-       zend_throw_exception_object(value TSRMLS_CC);
-       zend_exception_restore(TSRMLS_C);
+       if (IS_UNUSED != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+               uint32_t nesting = 1;
 
-       HANDLE_EXCEPTION();
-}
+               if (UNEXPECTED(EG(exception) != NULL)) {
+                       zval_ptr_dtor_nogc(free_op2);
+                       HANDLE_EXCEPTION();
+               }
 
-static int ZEND_FASTCALL  ZEND_SEND_VAR_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval *varptr, *arg;
+               zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s",  Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
+               zval_ptr_dtor_nogc(free_op2);
 
+               if (EG(exception) != NULL) {
+                       HANDLE_EXCEPTION();
+               }
 
-       varptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-       arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
-       ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
-       if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(varptr)) {
-               ZVAL_COPY(arg, Z_REFVAL_P(varptr));
+               /* No exception raised: Skip over arguments until fcall opcode with correct
+                * nesting level. Return NULL (except when return value unused) */
+               do {
+                       opline++;
+                       if (opline->opcode == ZEND_INIT_FCALL ||
+                               opline->opcode == ZEND_INIT_FCALL_BY_NAME ||
+                               opline->opcode == ZEND_INIT_NS_FCALL_BY_NAME ||
+                               opline->opcode == ZEND_INIT_METHOD_CALL ||
+                               opline->opcode == ZEND_INIT_STATIC_METHOD_CALL ||
+                               opline->opcode == ZEND_INIT_USER_CALL ||
+                               opline->opcode == ZEND_NEW
+                       ) {
+                               nesting++;
+                       } else if (opline->opcode == ZEND_DO_FCALL) {
+                               nesting--;
+                       }
+               } while (nesting);
 
-       } else {
-               ZVAL_COPY_VALUE(arg, varptr);
-               if (IS_CV == IS_CV) {
-                       if (Z_OPT_REFCOUNTED_P(arg)) Z_ADDREF_P(arg);
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
+
+               /* We've skipped EXT_FCALL_BEGIND, so also skip the ending opcode */
+               if ((opline + 1)->opcode == ZEND_EXT_FCALL_END) {
+                       opline++;
                }
+               ZEND_VM_JMP(++opline);
        }
-       ZEND_VM_NEXT_OPCODE();
-}
 
-static int ZEND_FASTCALL  ZEND_SEND_VAR_NO_REF_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       obj = Z_OBJ_P(object);
+       called_scope = obj->ce;
 
-       zval *varptr, *arg;
+       if ((IS_TMP_VAR|IS_VAR) != IS_CONST ||
+           EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
+           zend_object *orig_obj = obj;
 
-       SAVE_OPLINE();
+               if (UNEXPECTED(obj->handlers->get_method == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Object does not support method calls");
+               }
 
-       if (!(opline->extended_value & ZEND_ARG_COMPILE_TIME_BOUND)) {
-               if (!ARG_SHOULD_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
-                       return ZEND_SEND_VAR_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               /* First, locate the function. */
+               fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
+               if (UNEXPECTED(fbc == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
+               }
+               if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
+                   EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
+                   EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
+                   EXPECTED(obj == orig_obj)) {
+                       CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope, fbc);
                }
        }
 
-       varptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-       if ((!(opline->extended_value & ZEND_ARG_SEND_FUNCTION) ||
-            (Z_VAR_FLAGS_P(varptr) & IS_VAR_RET_REF)) &&
-           (Z_ISREF_P(varptr) || Z_TYPE_P(varptr) == IS_OBJECT)) {
-
-               ZVAL_MAKE_REF(varptr);
-               if (IS_CV == IS_CV) {
-                       Z_ADDREF_P(varptr);
-               }
+       if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_STATIC) != 0)) {
+               obj = NULL;
        } else {
-               if ((opline->extended_value & ZEND_ARG_COMPILE_TIME_BOUND) ?
-                       !(opline->extended_value & ZEND_ARG_SEND_SILENT) :
-                       !ARG_MAY_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
-                       zend_error(E_STRICT, "Only variables should be passed by reference");
-               }
+               GC_REFCOUNT(obj)++; /* For $this pointer */
        }
 
-       arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
-       ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
-       ZVAL_COPY_VALUE(arg, varptr);
+       EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
+               fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
+
+       zval_ptr_dtor_nogc(free_op2);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_SEND_REF_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
+       zval *array;
+       uint32_t size;
        USE_OPLINE
 
-       zval *varptr, *arg;
-
-       SAVE_OPLINE();
-       varptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+       array = EX_VAR(opline->result.var);
+       if (IS_UNUSED != IS_UNUSED) {
+               size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
+       } else {
+               size = 0;
+       }
+       ZVAL_NEW_ARR(array);
+       zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
 
-       if (IS_CV == IS_VAR && UNEXPECTED(varptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Only variables can be passed by reference");
+       if (IS_UNUSED != IS_UNUSED) {
+               /* Explicitly initialize array as not-packed if flag is set */
+               if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
+                       zend_hash_real_init(Z_ARRVAL_P(array), 0);
+               }
        }
 
-       arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
-       ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
-       if (IS_CV == IS_VAR && UNEXPECTED(varptr == &EG(error_zval))) {
-               ZVAL_NEW_REF(arg, &EG(uninitialized_zval));
+       if (IS_UNUSED == IS_UNUSED) {
                ZEND_VM_NEXT_OPCODE();
+#if 0 || IS_UNUSED != IS_UNUSED
+       } else {
+               return ZEND_ADD_ARRAY_ELEMENT_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+#endif
        }
+}
 
-       if (Z_ISREF_P(varptr)) {
-               Z_ADDREF_P(varptr);
-               ZVAL_COPY_VALUE(arg, varptr);
-       } else if (IS_CV == IS_VAR &&
-               UNEXPECTED(Z_TYPE_P(EX_VAR(opline->op1.var)) != IS_INDIRECT)) {
-               ZVAL_NEW_REF(arg, varptr);
+static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op2;
+       zval *container;
+       zval *offset;
+       zend_ulong hval;
+
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_unused(execute_data);
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
+       }
+       if (IS_UNUSED != IS_UNUSED) {
+               ZVAL_DEREF(container);
+       }
+       SEPARATE_ZVAL_NOREF(container);
+       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+
+       if (IS_UNUSED != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
+               HashTable *ht = Z_ARRVAL_P(container);
+offset_again:
+               switch (Z_TYPE_P(offset)) {
+                       case IS_DOUBLE:
+                               hval = zend_dval_to_lval(Z_DVAL_P(offset));
+                               zend_hash_index_del(ht, hval);
+                               break;
+                       case IS_LONG:
+                               hval = Z_LVAL_P(offset);
+num_index_dim:
+                               zend_hash_index_del(ht, hval);
+                               break;
+                       case IS_STRING:
+                               if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+                                       if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
+                                               goto num_index_dim;
+                                       }
+                               }
+                               if (ht == &EG(symbol_table).ht) {
+                                       zend_delete_global_variable(Z_STR_P(offset) TSRMLS_CC);
+                               } else {
+                                       zend_hash_del(ht, Z_STR_P(offset));
+                               }
+                               break;
+                       case IS_NULL:
+                               zend_hash_del(ht, STR_EMPTY_ALLOC());
+                               break;
+                       case IS_FALSE:
+                               hval = 0;
+                               goto num_index_dim;
+                       case IS_TRUE:
+                               hval = 1;
+                               goto num_index_dim;
+                       case IS_RESOURCE:
+                               hval = Z_RES_HANDLE_P(offset);
+                               goto num_index_dim;
+                       case IS_REFERENCE:
+                               offset = Z_REFVAL_P(offset);
+                               goto offset_again;
+                               break;
+                       default:
+                               zend_error(E_WARNING, "Illegal offset type in unset");
+                               break;
+               }
+               zval_ptr_dtor_nogc(free_op2);
+       } else if (IS_UNUSED == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+               if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot use object as array");
+               }
+//???          if ((IS_TMP_VAR|IS_VAR) == IS_CONST) {
+//???                  zval_copy_ctor(offset);
+//???          }
+               Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
+               zval_ptr_dtor_nogc(free_op2);
+       } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
+               ZEND_VM_CONTINUE(); /* bailed out before */
        } else {
-               ZVAL_NEW_REF(arg, varptr);
-               Z_ADDREF_P(arg);
-               ZVAL_REF(varptr, Z_REF_P(arg));
+               zval_ptr_dtor_nogc(free_op2);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_SEND_VAR_EX_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *varptr, *arg;
-
+       zend_free_op free_op2;
+       zval *container;
+       zval *offset;
 
-       if (ARG_SHOULD_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
-               return ZEND_SEND_REF_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_unused(execute_data);
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
        }
-       varptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-       arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
-       ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
-       if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(varptr)) {
-               ZVAL_COPY(arg, Z_REFVAL_P(varptr));
+       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       } else {
-               ZVAL_COPY_VALUE(arg, varptr);
-               if (IS_CV == IS_CV) {
-                       if (Z_OPT_REFCOUNTED_P(arg)) Z_ADDREF_P(arg);
+       if (IS_UNUSED != IS_UNUSED) {
+               ZVAL_DEREF(container);
+       }
+       if (IS_UNUSED == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
+               if (Z_OBJ_HT_P(container)->unset_property) {
+                       Z_OBJ_HT_P(container)->unset_property(container, offset, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+               } else {
+                       zend_error(E_NOTICE, "Trying to unset property of non-object");
                }
        }
+       zval_ptr_dtor_nogc(free_op2);
+
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_SEND_USER_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *arg, *param, tmp;
-
-
-       arg = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-       param = ZEND_CALL_ARG(EX(call), opline->op2.num);
-
-       if (ARG_SHOULD_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
-               // TODO: Scalar values don't have reference counters anymore.
-               // They are assumed to be 1, and they may be easily passed by
-               // reference now. However, previously scalars with refcount==1
-               // might be passed and with refcount>1 might not. We can support
-               // only single behavior ???
-#if 0
-               if (Z_REFCOUNTED_P(arg) &&
-                       // This solution breaks the following test (omit warning message) ???
-                       // Zend/tests/bug61273.phpt
-                       // ext/reflection/tests/bug42976.phpt
-                       // ext/standard/tests/general_functions/call_user_func_array_variation_001.phpt
-#else
-               if (!Z_REFCOUNTED_P(arg) ||
-                       // This solution breaks the following test (emit warning message) ???
-                       // ext/pdo_sqlite/tests/pdo_005.phpt
-#endif
-                   (!Z_ISREF_P(arg) /*&& Z_REFCOUNT_P(arg) > 1???*/)) {
+       zend_free_op free_op2;
+       zval *container;
+       int result;
+       zend_ulong hval;
+       zval *offset;
 
-                       if (!ARG_MAY_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_unused(execute_data);
+       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-                               zend_error(E_WARNING, "Parameter %d to %s%s%s() expected to be a reference, value given",
-                                       opline->op2.num,
-                                       EX(call)->func->common.scope ? EX(call)->func->common.scope->name->val : "",
-                                       EX(call)->func->common.scope ? "::" : "",
-                                       EX(call)->func->common.function_name->val);
+       if (IS_UNUSED != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
+               HashTable *ht = Z_ARRVAL_P(container);
+               zval *value;
+               zend_string *str;
 
-                               if (EX(call)->func->common.fn_flags & ZEND_ACC_CLOSURE) {
-                                       OBJ_RELEASE((zend_object*)EX(call)->func->common.prototype);
-                               }
-                               if (Z_OBJ(EX(call)->This)) {
-                                       OBJ_RELEASE(Z_OBJ(EX(call)->This));
+isset_again:
+               if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
+                       str = Z_STR_P(offset);
+                       if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+                               if (ZEND_HANDLE_NUMERIC(str, hval)) {
+                                       goto num_index_prop;
                                }
-                               EX(call)->func = (zend_function*)&zend_pass_function;
-                               EX(call)->called_scope = NULL;
-                               Z_OBJ(EX(call)->This) = NULL;
-
-                               CHECK_EXCEPTION();
-                               ZEND_VM_NEXT_OPCODE();
                        }
+str_index_prop:
+                       value = zend_hash_find_ind(ht, str);
+               } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
+                       hval = Z_LVAL_P(offset);
+num_index_prop:
+                       value = zend_hash_index_find(ht, hval);
+               } else {
+                       switch (Z_TYPE_P(offset)) {
+                               case IS_DOUBLE:
+                                       hval = zend_dval_to_lval(Z_DVAL_P(offset));
+                                       goto num_index_prop;
+                               case IS_NULL:
+                                       str = STR_EMPTY_ALLOC();
+                                       goto str_index_prop;
+                               case IS_FALSE:
+                                       hval = 0;
+                                       goto num_index_prop;
+                               case IS_TRUE:
+                                       hval = 1;
+                                       goto num_index_prop;
+                               case IS_RESOURCE:
+                                       hval = Z_RES_HANDLE_P(offset);
+                                       goto num_index_prop;
+                               case IS_REFERENCE:
+                                       offset = Z_REFVAL_P(offset);
+                                       goto isset_again;
+                               default:
+                                       zend_error(E_WARNING, "Illegal offset type in isset or empty");
+                                       value = NULL;
+                                       break;
+                       }
+               }
 
-                       if (Z_REFCOUNTED_P(arg)) {
-                               Z_DELREF_P(arg);
+               if (opline->extended_value & ZEND_ISSET) {
+                       /* > IS_NULL means not IS_UNDEF and not IS_NULL */
+                       result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
+                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
+               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+                       result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
+               }
+       } else if (IS_UNUSED == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+               if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
+                       result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
+               } else {
+                       zend_error(E_NOTICE, "Trying to check element of non-array");
+                       result = 0;
+               }
+               if ((opline->extended_value & ZEND_ISSET) == 0) {
+                       result = !result;
+               }
+       } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
+               zval tmp;
+
+               result = 0;
+               if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
+                       if ((IS_TMP_VAR|IS_VAR) & (IS_CV|IS_VAR)) {
+                               ZVAL_DEREF(offset);
+                       }
+                       if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
+                                       || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
+                                               && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
+                               ZVAL_DUP(&tmp, offset);
+                               convert_to_long(&tmp);
+                               offset = &tmp;
                        }
-                       ZVAL_DUP(&tmp, arg);
-                       ZVAL_NEW_REF(arg, &tmp);
-                       Z_ADDREF_P(arg);
-               } else if (!Z_ISREF_P(arg)) {
-                       ZVAL_NEW_REF(arg, arg);
-                       Z_ADDREF_P(arg);
-               } else if (Z_REFCOUNTED_P(arg)) {
-                       Z_ADDREF_P(arg);
                }
-               ZVAL_COPY_VALUE(param, arg);
-       } else if (Z_ISREF_P(arg) &&
-                  /* don't separate references for __call */
-                  (EX(call)->func->common.fn_flags & ZEND_ACC_CALL_VIA_HANDLER) == 0) {
-               ZVAL_DUP(param, Z_REFVAL_P(arg));
+               if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
+                       if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
+                               if ((opline->extended_value & ZEND_ISSET) ||
+                                   Z_STRVAL_P(container)[offset->value.lval] != '0') {
+                                       result = 1;
+                               }
+                       }
+               }
+               if ((opline->extended_value & ZEND_ISSET) == 0) {
+                       result = !result;
+               }
        } else {
-               ZVAL_COPY(param, arg);
+               result = ((opline->extended_value & ZEND_ISSET) == 0);
        }
 
-       ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_BOOL_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       zval *retval = EX_VAR(opline->result.var);
-
-       SAVE_OPLINE();
-       /* PHP 3.0 returned "" for false and 1 for true, here we use 0 and 1 for now */
-       ZVAL_BOOL(retval, i_zend_is_true(_get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC) TSRMLS_CC));
+       zval_ptr_dtor_nogc(free_op2);
+       ZVAL_BOOL(EX_VAR(opline->result.var), result);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_CLONE_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
-       zval *obj;
-       zend_class_entry *ce;
-       zend_function *clone;
-       zend_object_clone_obj_t clone_call;
+       zend_free_op free_op2;
+       zval *container;
+       int result;
+       zval *offset;
 
        SAVE_OPLINE();
-       obj = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-
-       if (IS_CV == IS_CONST ||
-           (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(obj) != IS_OBJECT))) {
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       HANDLE_EXCEPTION();
-               }
-               zend_error_noreturn(E_ERROR, "__clone method called on non-object");
-       }
+       container = _get_obj_zval_ptr_unused(execute_data);
+       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       ce = Z_OBJCE_P(obj);
-       clone = ce ? ce->clone : NULL;
-       clone_call =  Z_OBJ_HT_P(obj)->clone_obj;
-       if (UNEXPECTED(clone_call == NULL)) {
-               if (ce) {
-                       zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object of class %s", ce->name->val);
+       if (IS_UNUSED == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+               if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
+                       result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
                } else {
-                       zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object");
+                       zend_error(E_NOTICE, "Trying to check property of non-object");
+                       result = 0;
                }
-       }
-
-       if (ce && clone) {
-               if (clone->op_array.fn_flags & ZEND_ACC_PRIVATE) {
-                       /* Ensure that if we're calling a private function, we're allowed to do so.
-                        */
-                       if (UNEXPECTED(ce != EG(scope))) {
-                               zend_error_noreturn(E_ERROR, "Call to private %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
-                       }
-               } else if ((clone->common.fn_flags & ZEND_ACC_PROTECTED)) {
-                       /* Ensure that if we're calling a protected function, we're allowed to do so.
-                        */
-                       if (UNEXPECTED(!zend_check_protected(zend_get_function_root_class(clone), EG(scope)))) {
-                               zend_error_noreturn(E_ERROR, "Call to protected %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
-                       }
+               if ((opline->extended_value & ZEND_ISSET) == 0) {
+                       result = !result;
                }
+       } else {
+               result = ((opline->extended_value & ZEND_ISSET) == 0);
        }
 
-       if (EXPECTED(EG(exception) == NULL)) {
-               ZVAL_OBJ(EX_VAR(opline->result.var), clone_call(obj TSRMLS_CC));
-               if (!RETURN_VALUE_USED(opline) || UNEXPECTED(EG(exception) != NULL)) {
-                       OBJ_RELEASE(Z_OBJ_P(EX_VAR(opline->result.var)));
-               }
-       }
+       zval_ptr_dtor_nogc(free_op2);
+       ZVAL_BOOL(EX_VAR(opline->result.var), result);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_CAST_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BW_NOT_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *expr;
-       zval *result = EX_VAR(opline->result.var);
 
        SAVE_OPLINE();
-       expr = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+       bitwise_not_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC) TSRMLS_CC);
 
-       switch (opline->extended_value) {
-               case IS_NULL:
-                       /* This code is taken from convert_to_null. However, it does not seems very useful,
-                        * because a conversion to null always results in the same value. This could only
-                        * be relevant if a cast_object handler for IS_NULL has some kind of side-effect. */
-#if 0
-                       if (IS_CV == IS_VAR || IS_CV == IS_CV) {
-                               ZVAL_DEREF(expr);
-                       }
-                       if (Z_TYPE_P(expr) == IS_OBJECT && Z_OBJ_HT_P(expr)->cast_object) {
-                               if (Z_OBJ_HT_P(expr)->cast_object(expr, result, IS_NULL TSRMLS_CC) == SUCCESS) {
-                                       break;
-                               }
-                       }
-#endif
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-                       ZVAL_NULL(result);
-                       break;
-               case _IS_BOOL:
-                       ZVAL_BOOL(result, zend_is_true(expr TSRMLS_CC));
-                       break;
-               case IS_LONG:
-                       ZVAL_LONG(result, zval_get_long(expr));
-                       break;
-               case IS_DOUBLE:
-                       ZVAL_DOUBLE(result, zval_get_double(expr));
-                       break;
-               case IS_STRING:
-                       ZVAL_STR(result, zval_get_string(expr));
-                       break;
-               default:
-                       /* If value is already of correct type, return it directly */
-                       if (Z_TYPE_P(expr) == opline->extended_value) {
-                               ZVAL_COPY_VALUE(result, expr);
-                               if (IS_CV == IS_CONST) {
-                                       if (UNEXPECTED(Z_OPT_COPYABLE_P(result))) {
-                                               zval_copy_ctor_func(result);
-                                       }
-                               } else if (IS_CV != IS_TMP_VAR) {
-                                       if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
-                               }
+static int ZEND_FASTCALL  ZEND_BOOL_NOT_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-                               CHECK_EXCEPTION();
-                               ZEND_VM_NEXT_OPCODE();
-                       }
 
-                       if (opline->extended_value == IS_ARRAY) {
-                               if (Z_TYPE_P(expr) != IS_OBJECT) {
-                                       ZVAL_NEW_ARR(result);
-                                       zend_hash_init(Z_ARRVAL_P(result), 8, NULL, ZVAL_PTR_DTOR, 0);
-                                       if (Z_TYPE_P(expr) != IS_NULL) {
-                                               expr = zend_hash_index_add_new(Z_ARRVAL_P(result), 0, expr);
-                                               if (IS_CV == IS_CONST) {
-                                                       if (UNEXPECTED(Z_OPT_COPYABLE_P(expr))) {
-                                                               zval_copy_ctor_func(expr);
-                                                       }
-                                               } else {
-                                                       if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
-                                               }
-                                       }
-                               } else {
-                                       ZVAL_COPY_VALUE(result, expr);
-                                       Z_ADDREF_P(result);
-                                       convert_to_array(result);
-                               }
-                       } else {
-                               if (Z_TYPE_P(expr) != IS_ARRAY) {
-                                       object_init(result);
-                                       if (Z_TYPE_P(expr) != IS_NULL) {
-                                               expr = zend_hash_str_add_new(Z_OBJPROP_P(result), "scalar", sizeof("scalar")-1, expr);
-                                               if (IS_CV == IS_CONST) {
-                                                       if (UNEXPECTED(Z_OPT_COPYABLE_P(expr))) {
-                                                               zval_copy_ctor_func(expr);
-                                                       }
-                                               } else {
-                                                       if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
-                                               }
-                                       }
-                               } else {
-                                       ZVAL_COPY_VALUE(result, expr);
-                                       zval_opt_copy_ctor(result);
-                                       convert_to_object(result);
-                               }
-                       }
-       }
+       SAVE_OPLINE();
+       boolean_not_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC) TSRMLS_CC);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INCLUDE_OR_EVAL_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_PRE_INC_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_op_array *new_op_array=NULL;
 
-       zval *inc_filename;
-       zval tmp_inc_filename;
-       zend_bool failure_retval=0;
+       zval *var_ptr;
 
        SAVE_OPLINE();
-       inc_filename = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+       var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
 
-       ZVAL_UNDEF(&tmp_inc_filename);
-       if (Z_TYPE_P(inc_filename) != IS_STRING) {
-               ZVAL_STR(&tmp_inc_filename, zval_get_string(inc_filename));
-               inc_filename = &tmp_inc_filename;
+       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
-       if (opline->extended_value != ZEND_EVAL && strlen(Z_STRVAL_P(inc_filename)) != Z_STRLEN_P(inc_filename)) {
-               if (opline->extended_value == ZEND_INCLUDE_ONCE || opline->extended_value == ZEND_INCLUDE) {
-                       zend_message_dispatcher(ZMSG_FAILED_INCLUDE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
-               } else {
-                       zend_message_dispatcher(ZMSG_FAILED_REQUIRE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
+       if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
+               fast_increment_function(var_ptr);
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
                }
-       } else {
-               switch (opline->extended_value) {
-                       case ZEND_INCLUDE_ONCE:
-                       case ZEND_REQUIRE_ONCE: {
-                                       zend_file_handle file_handle;
-                                       char *resolved_path;
-
-                                       resolved_path = zend_resolve_path(Z_STRVAL_P(inc_filename), (int)Z_STRLEN_P(inc_filename) TSRMLS_CC);
-                                       if (resolved_path) {
-                                               failure_retval = zend_hash_str_exists(&EG(included_files), resolved_path, (int)strlen(resolved_path));
-                                       } else {
-                                               resolved_path = Z_STRVAL_P(inc_filename);
-                                       }
+               ZEND_VM_NEXT_OPCODE();
+       }
 
-                                       if (failure_retval) {
-                                               /* do nothing, file already included */
-                                       } else if (SUCCESS == zend_stream_open(resolved_path, &file_handle TSRMLS_CC)) {
+       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
+       }
 
-                                               if (!file_handle.opened_path) {
-                                                       file_handle.opened_path = estrdup(resolved_path);
-                                               }
+       ZVAL_DEREF(var_ptr);
+       SEPARATE_ZVAL_NOREF(var_ptr);
 
-                                               if (zend_hash_str_add_empty_element(&EG(included_files), file_handle.opened_path, (int)strlen(file_handle.opened_path))) {
-                                                       new_op_array = zend_compile_file(&file_handle, (opline->extended_value==ZEND_INCLUDE_ONCE?ZEND_INCLUDE:ZEND_REQUIRE) TSRMLS_CC);
-                                                       zend_destroy_file_handle(&file_handle TSRMLS_CC);
-                                               } else {
-                                                       zend_file_handle_dtor(&file_handle TSRMLS_CC);
-                                                       failure_retval=1;
-                                               }
-                                       } else {
-                                               if (opline->extended_value == ZEND_INCLUDE_ONCE) {
-                                                       zend_message_dispatcher(ZMSG_FAILED_INCLUDE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
-                                               } else {
-                                                       zend_message_dispatcher(ZMSG_FAILED_REQUIRE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
-                                               }
-                                       }
-                                       if (resolved_path != Z_STRVAL_P(inc_filename)) {
-                                               efree(resolved_path);
-                                       }
-                               }
-                               break;
-                       case ZEND_INCLUDE:
-                       case ZEND_REQUIRE:
-                               new_op_array = compile_filename(opline->extended_value, inc_filename TSRMLS_CC);
-                               break;
-                       case ZEND_EVAL: {
-                                       char *eval_desc = zend_make_compiled_string_description("eval()'d code" TSRMLS_CC);
+       increment_function(var_ptr);
 
-                                       new_op_array = zend_compile_string(inc_filename, eval_desc TSRMLS_CC);
-                                       efree(eval_desc);
-                               }
-                               break;
-                       EMPTY_SWITCH_DEFAULT_CASE()
-               }
-       }
-       if (Z_TYPE(tmp_inc_filename) != IS_UNDEF) {
-               zend_string_release(Z_STR(tmp_inc_filename));
+       if (RETURN_VALUE_USED(opline)) {
+               ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
        }
 
-       if (UNEXPECTED(EG(exception) != NULL)) {
-               HANDLE_EXCEPTION();
-       } else if (EXPECTED(new_op_array != NULL)) {
-               zval *return_value = NULL;
-               zend_execute_data *call;
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-               if (RETURN_VALUE_USED(opline)) {
-                       return_value = EX_VAR(opline->result.var);
-               }
+static int ZEND_FASTCALL  ZEND_PRE_DEC_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-               new_op_array->scope = EG(scope); /* ??? */
+       zval *var_ptr;
 
-               call = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_CODE,
-                       (zend_function*)new_op_array, 0, EX(called_scope), Z_OBJ(EX(This)), NULL TSRMLS_CC);
+       SAVE_OPLINE();
+       var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
 
-               if (EX(symbol_table)) {
-                       call->symbol_table = EX(symbol_table);
-               } else {
-                       call->symbol_table = zend_rebuild_symbol_table(TSRMLS_C);
-               }
+       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
+       }
 
-               call->prev_execute_data = execute_data;
-           i_init_code_execute_data(call, new_op_array, return_value TSRMLS_CC);
-               if (EXPECTED(zend_execute_ex == execute_ex)) {
-                       ZEND_VM_ENTER();
-               } else {
-                       ZEND_ADD_CALL_FLAG(call, ZEND_CALL_TOP);
-                       zend_execute_ex(call TSRMLS_CC);
+       if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
+               fast_decrement_function(var_ptr);
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
                }
+               ZEND_VM_NEXT_OPCODE();
+       }
 
-               destroy_op_array(new_op_array TSRMLS_CC);
-               efree_size(new_op_array, sizeof(zend_op_array));
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       zend_throw_exception_internal(NULL TSRMLS_CC);
-                       HANDLE_EXCEPTION();
+       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
                }
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
+       }
 
-       } else if (RETURN_VALUE_USED(opline)) {
-               ZVAL_BOOL(EX_VAR(opline->result.var), failure_retval);
+       ZVAL_DEREF(var_ptr);
+       SEPARATE_ZVAL_NOREF(var_ptr);
+
+       decrement_function(var_ptr);
+
+       if (RETURN_VALUE_USED(opline)) {
+               ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
        }
+
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_POST_INC_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *array_ptr, *array_ref, iterator, tmp;
-       HashTable *fe_ht;
-       zend_object_iterator *iter = NULL;
-       zend_class_entry *ce = NULL;
-       zend_bool is_empty = 0;
+       zval *var_ptr;
 
        SAVE_OPLINE();
+       var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
 
-       if ((IS_CV == IS_CV || IS_CV == IS_VAR) &&
-           (opline->extended_value & ZEND_FE_FETCH_BYREF)) {
-               array_ptr = array_ref = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-               ZVAL_DEREF(array_ptr);
-               if (Z_TYPE_P(array_ptr) == IS_ARRAY) {
-                       SEPARATE_ARRAY(array_ptr);
-                       if (!Z_ISREF_P(array_ref)) {
-                               ZVAL_NEW_REF(array_ref, array_ref);
-                               array_ptr = Z_REFVAL_P(array_ref);
-                       }
-                       if (Z_REFCOUNTED_P(array_ref)) Z_ADDREF_P(array_ref);
-               } else if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
-                       ce = Z_OBJCE_P(array_ptr);
-                       if (ce->get_iterator == NULL) {
-                               Z_ADDREF_P(array_ptr);
-                       }
-                       array_ref = array_ptr;
-               } else {
-                       if (Z_REFCOUNTED_P(array_ref)) Z_ADDREF_P(array_ref);
-               }
-       } else {
-               array_ptr = array_ref = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-               ZVAL_DEREF(array_ptr);
-               if (IS_CV == IS_TMP_VAR) {
-                       ZVAL_COPY_VALUE(&tmp, array_ptr);
-                       if (Z_OPT_IMMUTABLE_P(&tmp)) {
-                               zval_copy_ctor_func(&tmp);
-                       }
-                       array_ref = array_ptr = &tmp;
-                       if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
-                               ce = Z_OBJCE_P(array_ptr);
-                               if (ce && ce->get_iterator) {
-                                       Z_DELREF_P(array_ref);
-                               }
-                       }
-               } else if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
-                       ce = Z_OBJCE_P(array_ptr);
-                       if (!ce->get_iterator) {
-                               if (IS_CV == IS_CV) {
-                                       Z_ADDREF_P(array_ref);
-                               }
-                       }
-               } else if (Z_IMMUTABLE_P(array_ref)) {
-                       if (IS_CV == IS_CV) {
-                               zval_copy_ctor_func(array_ref);
-                               Z_ADDREF_P(array_ref);
-                       } else {
-                               ZVAL_COPY_VALUE(&tmp, array_ref);
-                               zval_copy_ctor_func(&tmp);
-                               array_ptr = array_ref = &tmp;
-                       }
-               } else if (Z_REFCOUNTED_P(array_ref)) {
-                       if (IS_CV == IS_CONST ||
-                                  (IS_CV == IS_CV &&
-                                   !Z_ISREF_P(array_ref) &&
-                                   Z_REFCOUNT_P(array_ref) > 1) ||
-                                  (IS_CV == IS_VAR &&
-                                   !Z_ISREF_P(array_ref) &&
-                                   Z_REFCOUNT_P(array_ref) > 2)) {
-                               if (IS_CV == IS_VAR) {
-                                       Z_DELREF_P(array_ref);
-                               }
-                               ZVAL_DUP(&tmp, array_ref);
-                               array_ptr = array_ref = &tmp;
-                       } else if (IS_CV == IS_CV || IS_CV == IS_VAR) {
-                               if (Z_ISREF_P(array_ref) && Z_REFCOUNT_P(array_ref) == 1) {
-                                       ZVAL_UNREF(array_ref);
-                                       array_ptr = array_ref;
-                               }
-                               if (Z_IMMUTABLE_P(array_ptr)) {
-                                       zval_copy_ctor_func(array_ptr);
-                               } else if (Z_ISREF_P(array_ref) &&
-                                          Z_COPYABLE_P(array_ptr) &&
-                                          Z_REFCOUNT_P(array_ptr) > 1) {
-                                       Z_DELREF_P(array_ptr);
-                                       zval_copy_ctor_func(array_ptr);
-                               }
-                               if (IS_CV == IS_CV) {
-                                       Z_ADDREF_P(array_ref);
-                               }
-                       }
-               }
+       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
-       if (ce && ce->get_iterator) {
-               iter = ce->get_iterator(ce, array_ptr, opline->extended_value & ZEND_FE_FETCH_BYREF TSRMLS_CC);
-
-               if (IS_CV == IS_VAR && !(opline->extended_value & ZEND_FE_FETCH_BYREF)) {
-
-               }
-               if (iter && EXPECTED(EG(exception) == NULL)) {
-                       ZVAL_OBJ(&iterator, &iter->std);
-                       array_ptr = array_ref = &iterator;
-               } else {
-                       if (IS_CV == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
+       if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
+               ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
+               fast_increment_function(var_ptr);
+               ZEND_VM_NEXT_OPCODE();
+       }
 
-                       }
-                       if (!EG(exception)) {
-                               zend_throw_exception_ex(NULL, 0 TSRMLS_CC, "Object of type %s did not create an Iterator", ce->name->val);
-                       }
-                       zend_throw_exception_internal(NULL TSRMLS_CC);
-                       HANDLE_EXCEPTION();
-               }
+       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+               ZVAL_NULL(EX_VAR(opline->result.var));
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
        }
 
-       ZVAL_COPY_VALUE(EX_VAR(opline->result.var), array_ref);
+       ZVAL_DEREF(var_ptr);
+       ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
+       zval_opt_copy_ctor(var_ptr);
 
-       if (iter) {
-               iter->index = 0;
-               if (iter->funcs->rewind) {
-                       iter->funcs->rewind(iter TSRMLS_CC);
-                       if (UNEXPECTED(EG(exception) != NULL)) {
-                               zval_ptr_dtor(array_ref);
-                               if (IS_CV == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
+       increment_function(var_ptr);
 
-                               }
-                               HANDLE_EXCEPTION();
-                       }
-               }
-               is_empty = iter->funcs->valid(iter TSRMLS_CC) != SUCCESS;
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       zval_ptr_dtor(array_ref);
-                       if (IS_CV == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-                       }
-                       HANDLE_EXCEPTION();
-               }
-               iter->index = -1; /* will be set to 0 before using next handler */
-       } else if ((fe_ht = HASH_OF(array_ptr)) != NULL) {
-               HashPointer *ptr = (HashPointer*)EX_VAR((opline+2)->op1.var);
-               HashPosition pos = 0;
-               Bucket *p;
+static int ZEND_FASTCALL  ZEND_POST_DEC_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-               while (1) {
-                       if (pos >= fe_ht->nNumUsed) {
-                               is_empty = 1;
-                               if (IS_CV == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
+       zval *var_ptr;
 
-                               }
-                               ZEND_VM_JMP(opline->op2.jmp_addr);
-                       }
-                       p = fe_ht->arData + pos;
-                       if (Z_TYPE(p->val) == IS_UNDEF ||
-                           (Z_TYPE(p->val) == IS_INDIRECT &&
-                            Z_TYPE_P(Z_INDIRECT(p->val)) == IS_UNDEF)) {
-                               pos++;
-                               continue;
-                       }
-                       if (!ce ||
-                           !p->key ||
-                           zend_check_property_access(Z_OBJ_P(array_ptr), p->key TSRMLS_CC) == SUCCESS) {
-                               break;
-                       }
-                       pos++;
-               }
-               fe_ht->nInternalPointer = pos;
-               ptr->pos = pos;
-               ptr->ht = fe_ht;
-               ptr->h = fe_ht->arData[pos].h;
-               ptr->key = fe_ht->arData[pos].key;
-               is_empty = 0;
-       } else {
-               zend_error(E_WARNING, "Invalid argument supplied for foreach()");
-               is_empty = 1;
-       }
+       SAVE_OPLINE();
+       var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
+       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
+       }
 
+       if (EXPECTED(Z_TYPE_P(var_ptr) == IS_LONG)) {
+               ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
+               fast_decrement_function(var_ptr);
+               ZEND_VM_NEXT_OPCODE();
        }
-       if (is_empty) {
-               ZEND_VM_JMP(opline->op2.jmp_addr);
-       } else {
+
+       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+               ZVAL_NULL(EX_VAR(opline->result.var));
                CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
+
+       ZVAL_DEREF(var_ptr);
+       ZVAL_COPY_VALUE(EX_VAR(opline->result.var), var_ptr);
+       zval_opt_copy_ctor(var_ptr);
+
+       decrement_function(var_ptr);
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_EXIT_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ECHO_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-#if 0 || (IS_CV != IS_UNUSED)
        USE_OPLINE
 
+       zval *z;
+
        SAVE_OPLINE();
-       if (IS_CV != IS_UNUSED) {
+       z = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
 
-               zval *ptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+       zend_print_variable(z TSRMLS_CC);
 
-               if (Z_TYPE_P(ptr) == IS_LONG) {
-                       EG(exit_status) = Z_LVAL_P(ptr);
-               } else {
-                       zend_print_variable(ptr TSRMLS_CC);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_PRINT_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       ZVAL_LONG(EX_VAR(opline->result.var), 1);
+       return ZEND_ECHO_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL  ZEND_JMPZ_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       zval *val;
+
+       SAVE_OPLINE();
+       val = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_TMP_VAR) {
+               if (Z_TYPE_P(val) == IS_TRUE) {
+                       ZEND_VM_SET_OPCODE(opline + 1);
+                       ZEND_VM_CONTINUE();
+               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+                       ZEND_VM_CONTINUE();
                }
+       }
 
+       if (i_zend_is_true(val TSRMLS_CC)) {
+               opline++;
+       } else {
+               opline = opline->op2.jmp_addr;
        }
-#endif
-       zend_bailout();
-       ZEND_VM_NEXT_OPCODE(); /* Never reached */
+
+       if (UNEXPECTED(EG(exception) != NULL)) {
+               HANDLE_EXCEPTION();
+       }
+       ZEND_VM_JMP(opline);
 }
 
-static int ZEND_FASTCALL  ZEND_JMP_SET_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_JMPNZ_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *value;
-       int is_ref = 0;
+       zval *val;
 
        SAVE_OPLINE();
-       value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+       val = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
 
-       if ((IS_CV == IS_VAR || IS_CV == IS_CV) && Z_ISREF_P(value)) {
-               is_ref = 1;
-               value = Z_REFVAL_P(value);
+       if (IS_CV == IS_TMP_VAR) {
+               if (Z_TYPE_P(val) == IS_TRUE) {
+                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+                       ZEND_VM_CONTINUE();
+               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+                       ZEND_VM_SET_OPCODE(opline + 1);
+                       ZEND_VM_CONTINUE();
+               }
        }
-       if (i_zend_is_true(value TSRMLS_CC)) {
-               ZVAL_COPY_VALUE(EX_VAR(opline->result.var), value);
-               if (IS_CV == IS_CONST) {
-                       if (UNEXPECTED(Z_OPT_COPYABLE_P(value))) {
-                               zval_copy_ctor_func(EX_VAR(opline->result.var));
-                       }
-               } else if (IS_CV == IS_CV) {
-                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
-               } else if (IS_CV == IS_VAR && is_ref) {
-                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
 
-               }
-               ZEND_VM_JMP(opline->op2.jmp_addr);
+       if (i_zend_is_true(val TSRMLS_CC)) {
+               opline = opline->op2.jmp_addr;
+       } else {
+               opline++;
        }
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       if (UNEXPECTED(EG(exception) != NULL)) {
+               HANDLE_EXCEPTION();
+       }
+       ZEND_VM_JMP(opline);
 }
 
-static int ZEND_FASTCALL  ZEND_COALESCE_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_JMPZNZ_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *value;
-       int is_ref = 0;
+       zval *val;
 
        SAVE_OPLINE();
-       value = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
+       val = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
 
-       if ((IS_CV == IS_VAR || IS_CV == IS_CV) && Z_ISREF_P(value)) {
-               is_ref = 1;
-               value = Z_REFVAL_P(value);
+       if (IS_CV == IS_TMP_VAR) {
+               if (EXPECTED(Z_TYPE_P(val) == IS_TRUE)) {
+                       ZEND_VM_SET_RELATIVE_OPCODE(opline, opline->extended_value);
+                       ZEND_VM_CONTINUE();
+               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+                       ZEND_VM_CONTINUE();
+               }
        }
 
-       if (Z_TYPE_P(value) > IS_NULL) {
-               ZVAL_COPY_VALUE(EX_VAR(opline->result.var), value);
-               if (IS_CV == IS_CONST) {
-                       if (UNEXPECTED(Z_OPT_COPYABLE_P(value))) {
-                               zval_copy_ctor_func(EX_VAR(opline->result.var));
-                       }
-               } else if (IS_CV == IS_CV) {
-                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
-               } else if (IS_CV == IS_VAR && is_ref) {
-                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
-
-               }
-               ZEND_VM_JMP(opline->op2.jmp_addr);
+       if (i_zend_is_true(val TSRMLS_CC)) {
+               opline = (zend_op*)(((char*)opline) + opline->extended_value);
+       } else {
+               opline = opline->op2.jmp_addr;
        }
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       if (UNEXPECTED(EG(exception) != NULL)) {
+               HANDLE_EXCEPTION();
+       }
+       ZEND_VM_JMP(opline);
 }
 
-static int ZEND_FASTCALL  ZEND_QM_ASSIGN_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_JMPZ_EX_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *value;
+       zval *val;
 
        SAVE_OPLINE();
-       value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+       val = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
 
-       if ((IS_CV == IS_VAR || IS_CV == IS_CV) && Z_ISREF_P(value)) {
-               ZVAL_COPY(EX_VAR(opline->result.var), Z_REFVAL_P(value));
+       if (IS_CV == IS_TMP_VAR) {
+               if (Z_TYPE_P(val) == IS_TRUE) {
+                       ZVAL_TRUE(EX_VAR(opline->result.var));
+                       ZEND_VM_SET_OPCODE(opline + 1);
+                       ZEND_VM_CONTINUE();
+               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+                       ZVAL_FALSE(EX_VAR(opline->result.var));
+                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+                       ZEND_VM_CONTINUE();
+               }
+       }
+
+       if (i_zend_is_true(val TSRMLS_CC)) {
 
+               ZVAL_TRUE(EX_VAR(opline->result.var));
+               opline++;
        } else {
-               ZVAL_COPY_VALUE(EX_VAR(opline->result.var), value);
-               if (IS_CV == IS_CONST) {
-                       if (UNEXPECTED(Z_OPT_COPYABLE_P(value))) {
-                               zval_copy_ctor_func(EX_VAR(opline->result.var));
-                       }
-               } else if (IS_CV == IS_CV) {
-                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
-               }
+
+               ZVAL_FALSE(EX_VAR(opline->result.var));
+               opline = opline->op2.jmp_addr;
        }
-       ZEND_VM_NEXT_OPCODE();
+       if (UNEXPECTED(EG(exception) != NULL)) {
+               HANDLE_EXCEPTION();
+       }
+       ZEND_VM_JMP(opline);
 }
 
-static int ZEND_FASTCALL  ZEND_STRLEN_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_JMPNZ_EX_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *value;
 
+       zval *val;
 
        SAVE_OPLINE();
-       value = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-       if (EXPECTED(Z_TYPE_P(value) == IS_STRING)) {
-               ZVAL_LONG(EX_VAR(opline->result.var), Z_STRLEN_P(value));
-       } else {
-               if (Z_TYPE_P(value) < IS_TRUE) {
-                       ZVAL_LONG(EX_VAR(opline->result.var), 0);
-               } else if (Z_TYPE_P(value) == IS_TRUE) {
-                       ZVAL_LONG(EX_VAR(opline->result.var), 1);
-               } else if (Z_TYPE_P(value) <= IS_DOUBLE) {
-                       zend_string *str = zval_get_string(value);
-                       ZVAL_LONG(EX_VAR(opline->result.var), str->len);
-                       zend_string_release(str);
-               } else if (Z_TYPE_P(value) == IS_OBJECT) {
-                       zend_string *str;
-                       zval tmp;
+       val = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
 
-                       ZVAL_COPY(&tmp, value);
-                       if (parse_arg_object_to_str(&tmp, &str, IS_STRING TSRMLS_CC) == FAILURE) {
-                               goto strlen_error;
-                       }
-                       ZVAL_LONG(EX_VAR(opline->result.var), str->len);
-                       zval_dtor(&tmp);
-               } else {
-strlen_error:
-                       zend_error(E_WARNING, "strlen() expects parameter 1 to be string, %s given", zend_get_type_by_const(Z_TYPE_P(value)));
-                       ZVAL_NULL(EX_VAR(opline->result.var));
+       if (IS_CV == IS_TMP_VAR) {
+               if (Z_TYPE_P(val) == IS_TRUE) {
+                       ZVAL_TRUE(EX_VAR(opline->result.var));
+                       ZEND_VM_SET_OPCODE(opline->op2.jmp_addr);
+                       ZEND_VM_CONTINUE();
+               } else if (EXPECTED(Z_TYPE_P(val) <= IS_TRUE)) {
+                       ZVAL_FALSE(EX_VAR(opline->result.var));
+                       ZEND_VM_SET_OPCODE(opline + 1);
+                       ZEND_VM_CONTINUE();
                }
        }
+       if (i_zend_is_true(val TSRMLS_CC)) {
+               ZVAL_TRUE(EX_VAR(opline->result.var));
+               opline = opline->op2.jmp_addr;
+       } else {
+               ZVAL_FALSE(EX_VAR(opline->result.var));
+               opline++;
+       }
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       if (UNEXPECTED(EG(exception) != NULL)) {
+               HANDLE_EXCEPTION();
+       }
+       ZEND_VM_JMP(opline);
 }
 
-static int ZEND_FASTCALL  ZEND_TYPE_CHECK_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_RETURN_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *value;
+       zval *retval_ptr;
 
 
        SAVE_OPLINE();
-       value = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-       switch (opline->extended_value) {
-               case IS_NULL:
-               case IS_LONG:
-               case IS_DOUBLE:
-               case IS_STRING:
-               case IS_ARRAY:
-                       ZVAL_BOOL(EX_VAR(opline->result.var), Z_TYPE_P(value) == opline->extended_value);
-                       break;
-               case _IS_BOOL:
-                       ZVAL_BOOL(EX_VAR(opline->result.var), Z_TYPE_P(value) == IS_TRUE || Z_TYPE_P(value) == IS_FALSE);
-                       break;
-               case IS_OBJECT:
-                       if (Z_TYPE_P(value) == opline->extended_value) {
-                               zend_class_entry *ce = Z_OBJCE_P(value);
-                               if (ce->name->len == sizeof("__PHP_Incomplete_Class") - 1
-                                               && !strncmp(ce->name->val, "__PHP_Incomplete_Class", ce->name->len)) {
-                                       ZVAL_FALSE(EX_VAR(opline->result.var));
-                               } else {
-                                       ZVAL_TRUE(EX_VAR(opline->result.var));
+       retval_ptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+
+       if (!EX(return_value)) {
+
+       } else {
+               if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
+                       ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
+                       if (IS_CV == IS_CONST) {
+                               if (UNEXPECTED(Z_OPT_COPYABLE_P(EX(return_value)))) {
+                                       zval_copy_ctor_func(EX(return_value));
                                }
-                       } else {
-                               ZVAL_FALSE(EX_VAR(opline->result.var));
                        }
-                       break;
-               case IS_RESOURCE:
-                       if (Z_TYPE_P(value) == opline->extended_value) {
-                               const char *type_name = zend_rsrc_list_get_rsrc_type(Z_RES_P(value) TSRMLS_CC);
-                               ZVAL_BOOL(EX_VAR(opline->result.var), type_name != NULL);
-                       } else {
-                               ZVAL_FALSE(EX_VAR(opline->result.var));
+               } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(retval_ptr)) {
+                       ZVAL_COPY(EX(return_value), Z_REFVAL_P(retval_ptr));
+
+               } else {
+                       ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
+                       if (IS_CV == IS_CV) {
+                               if (Z_OPT_REFCOUNTED_P(retval_ptr)) Z_ADDREF_P(retval_ptr);
                        }
-                       break;
-               EMPTY_SWITCH_DEFAULT_CASE()
+               }
        }
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_ADD_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_RETURN_BY_REF_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zval *retval_ptr;
 
 
        SAVE_OPLINE();
-       fast_add_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               opline->op2.zv TSRMLS_CC);
 
+       do {
+               if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR ||
+                   (IS_CV == IS_VAR && opline->extended_value == ZEND_RETURNS_VALUE)) {
+                       /* Not supposed to happen, but we'll allow it */
+                       zend_error(E_NOTICE, "Only variable references should be returned by reference");
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+                       retval_ptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+                       if (!EX(return_value)) {
+                               if (IS_CV == IS_TMP_VAR) {
 
-static int ZEND_FASTCALL  ZEND_SUB_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+                               }
+                       } else {
+                               ZVAL_COPY_VALUE(EX(return_value), retval_ptr);
+                               Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
+                               if (IS_CV != IS_TMP_VAR) {
+                                       zval_opt_copy_ctor_no_imm(EX(return_value));
+                               }
+                       }
+                       break;
+               }
 
+               retval_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
 
-       SAVE_OPLINE();
-       fast_sub_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               opline->op2.zv TSRMLS_CC);
+               if (IS_CV == IS_VAR && UNEXPECTED(retval_ptr == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot return string offsets by reference");
+               }
+
+               if (IS_CV == IS_VAR) {
+                       if (retval_ptr == &EG(uninitialized_zval) ||
+                           (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+                            !(Z_VAR_FLAGS_P(retval_ptr) & IS_VAR_RET_REF))) {
+                               zend_error(E_NOTICE, "Only variable references should be returned by reference");
+                               if (EX(return_value)) {
+                                       ZVAL_NEW_REF(EX(return_value), retval_ptr);
+                                       Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
+                                       if (Z_REFCOUNTED_P(retval_ptr)) Z_ADDREF_P(retval_ptr);
+                               }
+                               break;
+                       }
+               }
 
+               if (EX(return_value)) {
+                       ZVAL_MAKE_REF(retval_ptr);
+                       Z_ADDREF_P(retval_ptr);
+                       ZVAL_REF(EX(return_value), Z_REF_P(retval_ptr));
+                       Z_VAR_FLAGS_P(EX(return_value)) = IS_VAR_RET_REF;
+               }
+       } while (0);
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_MUL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_THROW_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zval *value;
 
 
        SAVE_OPLINE();
-       fast_mul_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               opline->op2.zv TSRMLS_CC);
+       value = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
 
+       if (IS_CV == IS_CONST || UNEXPECTED(Z_TYPE_P(value) != IS_OBJECT)) {
+               if (UNEXPECTED(EG(exception) != NULL)) {
+                       HANDLE_EXCEPTION();
+               }
+               zend_error_noreturn(E_ERROR, "Can only throw objects");
+       }
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       zend_exception_save(TSRMLS_C);
+       if (IS_CV != IS_TMP_VAR) {
+               if (Z_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+       }
+
+       zend_throw_exception_object(value TSRMLS_CC);
+       zend_exception_restore(TSRMLS_C);
+
+       HANDLE_EXCEPTION();
 }
 
-static int ZEND_FASTCALL  ZEND_DIV_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SEND_VAR_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zval *varptr, *arg;
 
 
-       SAVE_OPLINE();
-       fast_div_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               opline->op2.zv TSRMLS_CC);
-
+       varptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+       arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
+       ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
+       if (Z_ISREF_P(varptr)) {
+               ZVAL_COPY(arg, Z_REFVAL_P(varptr));
 
-       CHECK_EXCEPTION();
+       } else {
+               ZVAL_COPY_VALUE(arg, varptr);
+               if (IS_CV == IS_CV) {
+                       if (Z_OPT_REFCOUNTED_P(arg)) Z_ADDREF_P(arg);
+               }
+       }
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_MOD_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SEND_VAR_NO_REF_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
+       zval *varptr, *arg;
 
        SAVE_OPLINE();
-       fast_mod_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               opline->op2.zv TSRMLS_CC);
-
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
 
-static int ZEND_FASTCALL  ZEND_SL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       if (!(opline->extended_value & ZEND_ARG_COMPILE_TIME_BOUND)) {
+               if (!ARG_SHOULD_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
+                       return ZEND_SEND_VAR_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               }
+       }
 
+       varptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+       if ((!(opline->extended_value & ZEND_ARG_SEND_FUNCTION) ||
+            (Z_VAR_FLAGS_P(varptr) & IS_VAR_RET_REF)) &&
+           (Z_ISREF_P(varptr) || Z_TYPE_P(varptr) == IS_OBJECT)) {
 
-       SAVE_OPLINE();
-       shift_left_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               opline->op2.zv TSRMLS_CC);
+               ZVAL_MAKE_REF(varptr);
+               if (IS_CV == IS_CV) {
+                       Z_ADDREF_P(varptr);
+               }
+       } else {
+               if ((opline->extended_value & ZEND_ARG_COMPILE_TIME_BOUND) ?
+                       !(opline->extended_value & ZEND_ARG_SEND_SILENT) :
+                       !ARG_MAY_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
+                       zend_error(E_STRICT, "Only variables should be passed by reference");
+               }
+       }
 
+       arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
+       ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
+       ZVAL_COPY_VALUE(arg, varptr);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_SR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SEND_REF_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
+       zval *varptr, *arg;
 
        SAVE_OPLINE();
-       shift_right_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               opline->op2.zv TSRMLS_CC);
+       varptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_VAR && UNEXPECTED(varptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Only variables can be passed by reference");
+       }
 
+       arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
+       ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
+       if (IS_CV == IS_VAR && UNEXPECTED(varptr == &EG(error_zval))) {
+               ZVAL_NEW_REF(arg, &EG(uninitialized_zval));
+               ZEND_VM_NEXT_OPCODE();
+       }
+
+       if (Z_ISREF_P(varptr)) {
+               Z_ADDREF_P(varptr);
+               ZVAL_COPY_VALUE(arg, varptr);
+       } else if (IS_CV == IS_VAR &&
+               UNEXPECTED(Z_TYPE_P(EX_VAR(opline->op1.var)) != IS_INDIRECT)) {
+               ZVAL_NEW_REF(arg, varptr);
+       } else {
+               ZVAL_NEW_REF(arg, varptr);
+               Z_ADDREF_P(arg);
+               ZVAL_REF(varptr, Z_REF_P(arg));
+       }
 
-       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SEND_VAR_EX_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zval *varptr, *arg;
 
 
-       SAVE_OPLINE();
-       concat_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               opline->op2.zv TSRMLS_CC);
-
+       if (ARG_SHOULD_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
+               return ZEND_SEND_REF_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+       varptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+       arg = ZEND_CALL_ARG(EX(call), opline->op2.num);
+       ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
+       if (Z_ISREF_P(varptr)) {
+               ZVAL_COPY(arg, Z_REFVAL_P(varptr));
 
-       CHECK_EXCEPTION();
+       } else {
+               ZVAL_COPY_VALUE(arg, varptr);
+               if (IS_CV == IS_CV) {
+                       if (Z_OPT_REFCOUNTED_P(arg)) Z_ADDREF_P(arg);
+               }
+       }
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SEND_USER_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zval *arg, *param, tmp;
 
 
-       SAVE_OPLINE();
-       fast_is_identical_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               opline->op2.zv TSRMLS_CC);
+       arg = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+       param = ZEND_CALL_ARG(EX(call), opline->op2.num);
 
+       if (ARG_SHOULD_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
+               // TODO: Scalar values don't have reference counters anymore.
+               // They are assumed to be 1, and they may be easily passed by
+               // reference now. However, previously scalars with refcount==1
+               // might be passed and with refcount>1 might not. We can support
+               // only single behavior ???
+#if 0
+               if (Z_REFCOUNTED_P(arg) &&
+                       // This solution breaks the following test (omit warning message) ???
+                       // Zend/tests/bug61273.phpt
+                       // ext/reflection/tests/bug42976.phpt
+                       // ext/standard/tests/general_functions/call_user_func_array_variation_001.phpt
+#else
+               if (!Z_REFCOUNTED_P(arg) ||
+                       // This solution breaks the following test (emit warning message) ???
+                       // ext/pdo_sqlite/tests/pdo_005.phpt
+#endif
+                   (!Z_ISREF_P(arg) /*&& Z_REFCOUNT_P(arg) > 1???*/)) {
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+                       if (!ARG_MAY_BE_SENT_BY_REF(EX(call)->func, opline->op2.num)) {
 
-static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+                               zend_error(E_WARNING, "Parameter %d to %s%s%s() expected to be a reference, value given",
+                                       opline->op2.num,
+                                       EX(call)->func->common.scope ? EX(call)->func->common.scope->name->val : "",
+                                       EX(call)->func->common.scope ? "::" : "",
+                                       EX(call)->func->common.function_name->val);
 
-       zval *result = EX_VAR(opline->result.var);
+                               if (EX(call)->func->common.fn_flags & ZEND_ACC_CLOSURE) {
+                                       OBJ_RELEASE((zend_object*)EX(call)->func->common.prototype);
+                               }
+                               if (Z_OBJ(EX(call)->This)) {
+                                       OBJ_RELEASE(Z_OBJ(EX(call)->This));
+                               }
+                               EX(call)->func = (zend_function*)&zend_pass_function;
+                               EX(call)->called_scope = NULL;
+                               Z_OBJ(EX(call)->This) = NULL;
 
-       SAVE_OPLINE();
-       fast_is_not_identical_function(result,
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               opline->op2.zv TSRMLS_CC);
+                               CHECK_EXCEPTION();
+                               ZEND_VM_NEXT_OPCODE();
+                       }
+
+                       if (Z_REFCOUNTED_P(arg)) {
+                               Z_DELREF_P(arg);
+                       }
+                       ZVAL_DUP(&tmp, arg);
+                       ZVAL_NEW_REF(arg, &tmp);
+                       Z_ADDREF_P(arg);
+               } else if (!Z_ISREF_P(arg)) {
+                       ZVAL_NEW_REF(arg, arg);
+                       Z_ADDREF_P(arg);
+               } else if (Z_REFCOUNTED_P(arg)) {
+                       Z_ADDREF_P(arg);
+               }
+               ZVAL_COPY_VALUE(param, arg);
+       } else if (Z_ISREF_P(arg) &&
+                  /* don't separate references for __call */
+                  (EX(call)->func->common.fn_flags & ZEND_ACC_CALL_VIA_HANDLER) == 0) {
+               ZVAL_DUP(param, Z_REFVAL_P(arg));
+       } else {
+               ZVAL_COPY(param, arg);
+       }
 
+       ZEND_CALL_NUM_ARGS(EX(call)) = opline->op2.num;
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BOOL_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *result = EX_VAR(opline->result.var);
+       zval *retval = EX_VAR(opline->result.var);
 
        SAVE_OPLINE();
-       fast_equal_function(result,
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               opline->op2.zv TSRMLS_CC);
-
+       /* PHP 3.0 returned "" for false and 1 for true, here we use 0 and 1 for now */
+       ZVAL_BOOL(retval, i_zend_is_true(_get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC) TSRMLS_CC));
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_CLONE_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *result = EX_VAR(opline->result.var);
+       zval *obj;
+       zend_class_entry *ce;
+       zend_function *clone;
+       zend_object_clone_obj_t clone_call;
 
        SAVE_OPLINE();
-       fast_not_equal_function(result,
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               opline->op2.zv TSRMLS_CC);
-
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+       obj = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
 
-static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       if (IS_CV == IS_CONST ||
+           (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(obj) != IS_OBJECT))) {
+               if (UNEXPECTED(EG(exception) != NULL)) {
+                       HANDLE_EXCEPTION();
+               }
+               zend_error_noreturn(E_ERROR, "__clone method called on non-object");
+       }
 
-       zval *result = EX_VAR(opline->result.var);
+       ce = Z_OBJCE_P(obj);
+       clone = ce ? ce->clone : NULL;
+       clone_call =  Z_OBJ_HT_P(obj)->clone_obj;
+       if (UNEXPECTED(clone_call == NULL)) {
+               if (ce) {
+                       zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object of class %s", ce->name->val);
+               } else {
+                       zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object");
+               }
+       }
 
-       SAVE_OPLINE();
-       fast_is_smaller_function(result,
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               opline->op2.zv TSRMLS_CC);
+       if (ce && clone) {
+               if (clone->op_array.fn_flags & ZEND_ACC_PRIVATE) {
+                       /* Ensure that if we're calling a private function, we're allowed to do so.
+                        */
+                       if (UNEXPECTED(ce != EG(scope))) {
+                               zend_error_noreturn(E_ERROR, "Call to private %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
+                       }
+               } else if ((clone->common.fn_flags & ZEND_ACC_PROTECTED)) {
+                       /* Ensure that if we're calling a protected function, we're allowed to do so.
+                        */
+                       if (UNEXPECTED(!zend_check_protected(zend_get_function_root_class(clone), EG(scope)))) {
+                               zend_error_noreturn(E_ERROR, "Call to protected %s::__clone() from context '%s'", ce->name->val, EG(scope) ? EG(scope)->name->val : "");
+                       }
+               }
+       }
 
+       if (EXPECTED(EG(exception) == NULL)) {
+               ZVAL_OBJ(EX_VAR(opline->result.var), clone_call(obj TSRMLS_CC));
+               if (!RETURN_VALUE_USED(opline) || UNEXPECTED(EG(exception) != NULL)) {
+                       OBJ_RELEASE(Z_OBJ_P(EX_VAR(opline->result.var)));
+               }
+       }
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_CAST_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
+       zval *expr;
        zval *result = EX_VAR(opline->result.var);
 
        SAVE_OPLINE();
-       fast_is_smaller_or_equal_function(result,
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               opline->op2.zv TSRMLS_CC);
-
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+       expr = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
 
-static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       switch (opline->extended_value) {
+               case IS_NULL:
+                       /* This code is taken from convert_to_null. However, it does not seems very useful,
+                        * because a conversion to null always results in the same value. This could only
+                        * be relevant if a cast_object handler for IS_NULL has some kind of side-effect. */
+#if 0
+                       if (IS_CV == IS_VAR || IS_CV == IS_CV) {
+                               ZVAL_DEREF(expr);
+                       }
+                       if (Z_TYPE_P(expr) == IS_OBJECT && Z_OBJ_HT_P(expr)->cast_object) {
+                               if (Z_OBJ_HT_P(expr)->cast_object(expr, result, IS_NULL TSRMLS_CC) == SUCCESS) {
+                                       break;
+                               }
+                       }
+#endif
 
+                       ZVAL_NULL(result);
+                       break;
+               case _IS_BOOL:
+                       ZVAL_BOOL(result, zend_is_true(expr TSRMLS_CC));
+                       break;
+               case IS_LONG:
+                       ZVAL_LONG(result, zval_get_long(expr));
+                       break;
+               case IS_DOUBLE:
+                       ZVAL_DOUBLE(result, zval_get_double(expr));
+                       break;
+               case IS_STRING:
+                       ZVAL_STR(result, zval_get_string(expr));
+                       break;
+               default:
+                       /* If value is already of correct type, return it directly */
+                       if (Z_TYPE_P(expr) == opline->extended_value) {
+                               ZVAL_COPY_VALUE(result, expr);
+                               if (IS_CV == IS_CONST) {
+                                       if (UNEXPECTED(Z_OPT_COPYABLE_P(result))) {
+                                               zval_copy_ctor_func(result);
+                                       }
+                               } else if (IS_CV != IS_TMP_VAR) {
+                                       if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
+                               }
 
-       SAVE_OPLINE();
-       bitwise_or_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               opline->op2.zv TSRMLS_CC);
+                               CHECK_EXCEPTION();
+                               ZEND_VM_NEXT_OPCODE();
+                       }
 
+                       if (opline->extended_value == IS_ARRAY) {
+                               if (Z_TYPE_P(expr) != IS_OBJECT) {
+                                       ZVAL_NEW_ARR(result);
+                                       zend_hash_init(Z_ARRVAL_P(result), 8, NULL, ZVAL_PTR_DTOR, 0);
+                                       if (Z_TYPE_P(expr) != IS_NULL) {
+                                               expr = zend_hash_index_add_new(Z_ARRVAL_P(result), 0, expr);
+                                               if (IS_CV == IS_CONST) {
+                                                       if (UNEXPECTED(Z_OPT_COPYABLE_P(expr))) {
+                                                               zval_copy_ctor_func(expr);
+                                                       }
+                                               } else {
+                                                       if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
+                                               }
+                                       }
+                               } else {
+                                       ZVAL_COPY_VALUE(result, expr);
+                                       Z_ADDREF_P(result);
+                                       convert_to_array(result);
+                               }
+                       } else {
+                               if (Z_TYPE_P(expr) != IS_ARRAY) {
+                                       object_init(result);
+                                       if (Z_TYPE_P(expr) != IS_NULL) {
+                                               expr = zend_hash_str_add_new(Z_OBJPROP_P(result), "scalar", sizeof("scalar")-1, expr);
+                                               if (IS_CV == IS_CONST) {
+                                                       if (UNEXPECTED(Z_OPT_COPYABLE_P(expr))) {
+                                                               zval_copy_ctor_func(expr);
+                                                       }
+                                               } else {
+                                                       if (Z_OPT_REFCOUNTED_P(expr)) Z_ADDREF_P(expr);
+                                               }
+                                       }
+                               } else {
+                                       ZVAL_COPY_VALUE(result, expr);
+                                       zval_opt_copy_ctor(result);
+                                       convert_to_object(result);
+                               }
+                       }
+       }
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INCLUDE_OR_EVAL_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zend_op_array *new_op_array=NULL;
 
+       zval *inc_filename;
+       zval tmp_inc_filename;
+       zend_bool failure_retval=0;
 
        SAVE_OPLINE();
-       bitwise_and_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               opline->op2.zv TSRMLS_CC);
+       inc_filename = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
 
+       ZVAL_UNDEF(&tmp_inc_filename);
+       if (Z_TYPE_P(inc_filename) != IS_STRING) {
+               ZVAL_STR(&tmp_inc_filename, zval_get_string(inc_filename));
+               inc_filename = &tmp_inc_filename;
+       }
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+       if (opline->extended_value != ZEND_EVAL && strlen(Z_STRVAL_P(inc_filename)) != Z_STRLEN_P(inc_filename)) {
+               if (opline->extended_value == ZEND_INCLUDE_ONCE || opline->extended_value == ZEND_INCLUDE) {
+                       zend_message_dispatcher(ZMSG_FAILED_INCLUDE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
+               } else {
+                       zend_message_dispatcher(ZMSG_FAILED_REQUIRE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
+               }
+       } else {
+               switch (opline->extended_value) {
+                       case ZEND_INCLUDE_ONCE:
+                       case ZEND_REQUIRE_ONCE: {
+                                       zend_file_handle file_handle;
+                                       char *resolved_path;
 
-static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+                                       resolved_path = zend_resolve_path(Z_STRVAL_P(inc_filename), (int)Z_STRLEN_P(inc_filename) TSRMLS_CC);
+                                       if (resolved_path) {
+                                               failure_retval = zend_hash_str_exists(&EG(included_files), resolved_path, (int)strlen(resolved_path));
+                                       } else {
+                                               resolved_path = Z_STRVAL_P(inc_filename);
+                                       }
+
+                                       if (failure_retval) {
+                                               /* do nothing, file already included */
+                                       } else if (SUCCESS == zend_stream_open(resolved_path, &file_handle TSRMLS_CC)) {
 
+                                               if (!file_handle.opened_path) {
+                                                       file_handle.opened_path = estrdup(resolved_path);
+                                               }
 
-       SAVE_OPLINE();
-       bitwise_xor_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               opline->op2.zv TSRMLS_CC);
+                                               if (zend_hash_str_add_empty_element(&EG(included_files), file_handle.opened_path, (int)strlen(file_handle.opened_path))) {
+                                                       new_op_array = zend_compile_file(&file_handle, (opline->extended_value==ZEND_INCLUDE_ONCE?ZEND_INCLUDE:ZEND_REQUIRE) TSRMLS_CC);
+                                                       zend_destroy_file_handle(&file_handle TSRMLS_CC);
+                                               } else {
+                                                       zend_file_handle_dtor(&file_handle TSRMLS_CC);
+                                                       failure_retval=1;
+                                               }
+                                       } else {
+                                               if (opline->extended_value == ZEND_INCLUDE_ONCE) {
+                                                       zend_message_dispatcher(ZMSG_FAILED_INCLUDE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
+                                               } else {
+                                                       zend_message_dispatcher(ZMSG_FAILED_REQUIRE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
+                                               }
+                                       }
+                                       if (resolved_path != Z_STRVAL_P(inc_filename)) {
+                                               efree(resolved_path);
+                                       }
+                               }
+                               break;
+                       case ZEND_INCLUDE:
+                       case ZEND_REQUIRE:
+                               new_op_array = compile_filename(opline->extended_value, inc_filename TSRMLS_CC);
+                               break;
+                       case ZEND_EVAL: {
+                                       char *eval_desc = zend_make_compiled_string_description("eval()'d code" TSRMLS_CC);
 
+                                       new_op_array = zend_compile_string(inc_filename, eval_desc TSRMLS_CC);
+                                       efree(eval_desc);
+                               }
+                               break;
+                       EMPTY_SWITCH_DEFAULT_CASE()
+               }
+       }
+       if (Z_TYPE(tmp_inc_filename) != IS_UNDEF) {
+               zend_string_release(Z_STR(tmp_inc_filename));
+       }
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+       if (UNEXPECTED(EG(exception) != NULL)) {
+               HANDLE_EXCEPTION();
+       } else if (EXPECTED(new_op_array != NULL)) {
+               zval *return_value = NULL;
+               zend_execute_data *call;
 
-static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+               if (RETURN_VALUE_USED(opline)) {
+                       return_value = EX_VAR(opline->result.var);
+               }
 
+               new_op_array->scope = EG(scope); /* ??? */
 
-       SAVE_OPLINE();
-       boolean_xor_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               opline->op2.zv TSRMLS_CC);
+               call = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_CODE,
+                       (zend_function*)new_op_array, 0, EX(called_scope), Z_OBJ(EX(This)), NULL TSRMLS_CC);
 
+               if (EX(symbol_table)) {
+                       call->symbol_table = EX(symbol_table);
+               } else {
+                       call->symbol_table = zend_rebuild_symbol_table(TSRMLS_C);
+               }
 
-       CHECK_EXCEPTION();
+               call->prev_execute_data = execute_data;
+           i_init_code_execute_data(call, new_op_array, return_value TSRMLS_CC);
+               if (EXPECTED(zend_execute_ex == execute_ex)) {
+                       ZEND_VM_ENTER();
+               } else {
+                       ZEND_ADD_CALL_FLAG(call, ZEND_CALL_TOP);
+                       zend_execute_ex(call TSRMLS_CC);
+               }
+
+               destroy_op_array(new_op_array TSRMLS_CC);
+               efree_size(new_op_array, sizeof(zend_op_array));
+               if (UNEXPECTED(EG(exception) != NULL)) {
+                       zend_throw_exception_internal(NULL TSRMLS_CC);
+                       HANDLE_EXCEPTION();
+               }
+
+       } else if (RETURN_VALUE_USED(opline)) {
+               ZVAL_BOOL(EX_VAR(opline->result.var), failure_retval);
+       }
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op_data1;
-       zval *object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
-       zval *property = opline->op2.zv;
-       zval *value;
-       zval *zptr;
 
-       if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
-       }
+       zval *array_ptr, *array_ref, iterator, tmp;
+       HashTable *fe_ht;
+       zend_object_iterator *iter = NULL;
+       zend_class_entry *ce = NULL;
+       zend_bool is_empty = 0;
 
-       if (IS_CV != IS_UNUSED) {
-               object = make_real_object(object TSRMLS_CC);
+       SAVE_OPLINE();
+
+       if ((IS_CV == IS_CV || IS_CV == IS_VAR) &&
+           (opline->extended_value & ZEND_FE_FETCH_BYREF)) {
+               array_ptr = array_ref = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+               ZVAL_DEREF(array_ptr);
+               if (Z_TYPE_P(array_ptr) == IS_ARRAY) {
+                       SEPARATE_ARRAY(array_ptr);
+                       if (!Z_ISREF_P(array_ref)) {
+                               ZVAL_NEW_REF(array_ref, array_ref);
+                               array_ptr = Z_REFVAL_P(array_ref);
+                       }
+                       if (Z_REFCOUNTED_P(array_ref)) Z_ADDREF_P(array_ref);
+               } else if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
+                       ce = Z_OBJCE_P(array_ptr);
+                       if (ce->get_iterator == NULL) {
+                               Z_ADDREF_P(array_ptr);
+                       }
+                       array_ref = array_ptr;
+               } else {
+                       if (Z_REFCOUNTED_P(array_ref)) Z_ADDREF_P(array_ref);
+               }
+       } else {
+               array_ptr = array_ref = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+               ZVAL_DEREF(array_ptr);
+               if (IS_CV == IS_TMP_VAR) {
+                       ZVAL_COPY_VALUE(&tmp, array_ptr);
+                       if (Z_OPT_IMMUTABLE_P(&tmp)) {
+                               zval_copy_ctor_func(&tmp);
+                       }
+                       array_ref = array_ptr = &tmp;
+                       if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
+                               ce = Z_OBJCE_P(array_ptr);
+                               if (ce && ce->get_iterator) {
+                                       Z_DELREF_P(array_ref);
+                               }
+                       }
+               } else if (Z_TYPE_P(array_ptr) == IS_OBJECT) {
+                       ce = Z_OBJCE_P(array_ptr);
+                       if (!ce->get_iterator) {
+                               if (IS_CV == IS_CV) {
+                                       Z_ADDREF_P(array_ref);
+                               }
+                       }
+               } else if (Z_IMMUTABLE_P(array_ref)) {
+                       if (IS_CV == IS_CV) {
+                               zval_copy_ctor_func(array_ref);
+                               Z_ADDREF_P(array_ref);
+                       } else {
+                               ZVAL_COPY_VALUE(&tmp, array_ref);
+                               zval_copy_ctor_func(&tmp);
+                               array_ptr = array_ref = &tmp;
+                       }
+               } else if (Z_REFCOUNTED_P(array_ref)) {
+                       if (IS_CV == IS_CONST ||
+                                  (IS_CV == IS_CV &&
+                                   !Z_ISREF_P(array_ref) &&
+                                   Z_REFCOUNT_P(array_ref) > 1) ||
+                                  (IS_CV == IS_VAR &&
+                                   !Z_ISREF_P(array_ref) &&
+                                   Z_REFCOUNT_P(array_ref) > 2)) {
+                               if (IS_CV == IS_VAR) {
+                                       Z_DELREF_P(array_ref);
+                               }
+                               ZVAL_DUP(&tmp, array_ref);
+                               array_ptr = array_ref = &tmp;
+                       } else if (IS_CV == IS_CV || IS_CV == IS_VAR) {
+                               if (Z_ISREF_P(array_ref) && Z_REFCOUNT_P(array_ref) == 1) {
+                                       ZVAL_UNREF(array_ref);
+                                       array_ptr = array_ref;
+                               }
+                               if (Z_IMMUTABLE_P(array_ptr)) {
+                                       zval_copy_ctor_func(array_ptr);
+                               } else if (Z_ISREF_P(array_ref) &&
+                                          Z_COPYABLE_P(array_ptr) &&
+                                          Z_REFCOUNT_P(array_ptr) > 1) {
+                                       Z_DELREF_P(array_ptr);
+                                       zval_copy_ctor_func(array_ptr);
+                               }
+                               if (IS_CV == IS_CV) {
+                                       Z_ADDREF_P(array_ref);
+                               }
+                       }
+               }
        }
 
-       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+       if (ce && ce->get_iterator) {
+               iter = ce->get_iterator(ce, array_ptr, opline->extended_value & ZEND_FE_FETCH_BYREF TSRMLS_CC);
 
-       if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
-               zend_error(E_WARNING, "Attempt to assign property of non-object");
+               if (IS_CV == IS_VAR && !(opline->extended_value & ZEND_FE_FETCH_BYREF)) {
 
-               FREE_OP(free_op_data1);
+               }
+               if (iter && EXPECTED(EG(exception) == NULL)) {
+                       ZVAL_OBJ(&iterator, &iter->std);
+                       array_ptr = array_ref = &iterator;
+               } else {
+                       if (IS_CV == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
 
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
+                       }
+                       if (!EG(exception)) {
+                               zend_throw_exception_ex(NULL, 0 TSRMLS_CC, "Object of type %s did not create an Iterator", ce->name->val);
+                       }
+                       zend_throw_exception_internal(NULL TSRMLS_CC);
+                       HANDLE_EXCEPTION();
                }
-       } else {
-               /* here we are sure we are dealing with an object */
-               if (opline->extended_value == ZEND_ASSIGN_OBJ
-                       && EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-                       && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+       }
 
-                       ZVAL_DEREF(zptr);
-                       SEPARATE_ZVAL_NOREF(zptr);
+       ZVAL_COPY_VALUE(EX_VAR(opline->result.var), array_ref);
 
-                       binary_op(zptr, zptr, value TSRMLS_CC);
-                       if (RETURN_VALUE_USED(opline)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), zptr);
-                       }
-               } else {
-                       zval *z = NULL;
-                       zval rv;
+       if (iter) {
+               iter->index = 0;
+               if (iter->funcs->rewind) {
+                       iter->funcs->rewind(iter TSRMLS_CC);
+                       if (UNEXPECTED(EG(exception) != NULL)) {
+                               zval_ptr_dtor(array_ref);
+                               if (IS_CV == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
 
-                       if (opline->extended_value == ZEND_ASSIGN_OBJ) {
-                               if (Z_OBJ_HT_P(object)->read_property) {
-                                       z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
-                               }
-                       } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
-                               if (Z_OBJ_HT_P(object)->read_dimension) {
-                                       z = Z_OBJ_HT_P(object)->read_dimension(object, property, BP_VAR_R, &rv TSRMLS_CC);
                                }
+                               HANDLE_EXCEPTION();
                        }
-                       if (z) {
-                               if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
-                                       zval rv;
-                                       zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+               }
+               is_empty = iter->funcs->valid(iter TSRMLS_CC) != SUCCESS;
+               if (UNEXPECTED(EG(exception) != NULL)) {
+                       zval_ptr_dtor(array_ref);
+                       if (IS_CV == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
+
+                       }
+                       HANDLE_EXCEPTION();
+               }
+               iter->index = -1; /* will be set to 0 before using next handler */
+       } else if ((fe_ht = HASH_OF(array_ptr)) != NULL) {
+               HashPointer *ptr = (HashPointer*)EX_VAR((opline+2)->op1.var);
+               HashPosition pos = 0;
+               Bucket *p;
+
+               while (1) {
+                       if (pos >= fe_ht->nNumUsed) {
+                               is_empty = 1;
+                               if (IS_CV == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
 
-                                       if (Z_REFCOUNT_P(z) == 0) {
-                                               zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
-                                       }
-                                       ZVAL_COPY_VALUE(z, value);
-                               }
-//???                          if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
-                               SEPARATE_ZVAL_IF_NOT_REF(z);
-                               binary_op(z, z, value TSRMLS_CC);
-                               if (opline->extended_value == ZEND_ASSIGN_OBJ) {
-                                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
-                               } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
-                                       Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
-                               }
-                               if (RETURN_VALUE_USED(opline)) {
-                                       ZVAL_COPY(EX_VAR(opline->result.var), z);
-                               }
-                               zval_ptr_dtor(z);
-                       } else {
-                               zend_error(E_WARNING, "Attempt to assign property of non-object");
-                               if (RETURN_VALUE_USED(opline)) {
-                                       ZVAL_NULL(EX_VAR(opline->result.var));
                                }
+                               ZEND_VM_JMP(opline->op2.jmp_addr);
+                       }
+                       p = fe_ht->arData + pos;
+                       if (Z_TYPE(p->val) == IS_UNDEF ||
+                           (Z_TYPE(p->val) == IS_INDIRECT &&
+                            Z_TYPE_P(Z_INDIRECT(p->val)) == IS_UNDEF)) {
+                               pos++;
+                               continue;
+                       }
+                       if (!ce ||
+                           !p->key ||
+                           zend_check_property_access(Z_OBJ_P(array_ptr), p->key TSRMLS_CC) == SUCCESS) {
+                               break;
                        }
+                       pos++;
                }
-
-               FREE_OP(free_op_data1);
+               fe_ht->nInternalPointer = pos;
+               ptr->pos = pos;
+               ptr->ht = fe_ht;
+               ptr->h = fe_ht->arData[pos].h;
+               ptr->key = fe_ht->arData[pos].key;
+               is_empty = 0;
+       } else {
+               zend_error(E_WARNING, "Invalid argument supplied for foreach()");
+               is_empty = 1;
        }
 
-       /* assign_obj has two opcodes! */
-       CHECK_EXCEPTION();
-       ZEND_VM_INC_OPCODE();
-       ZEND_VM_NEXT_OPCODE();
+       if (IS_CV == IS_VAR && opline->extended_value & ZEND_FE_FETCH_BYREF) {
+
+       }
+       if (is_empty) {
+               ZEND_VM_JMP(opline->op2.jmp_addr);
+       } else {
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
+       }
 }
 
-static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_CV_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_EXIT_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
+#if 0 || (IS_CV != IS_UNUSED)
        USE_OPLINE
-       zend_free_op free_op_data1;
-       zval *var_ptr, rv;
-       zval *value, *container;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-       }
        if (IS_CV != IS_UNUSED) {
-               ZVAL_DEREF(container);
-       }
-       if (IS_CV == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (IS_CV == IS_VAR && !0) {
-                       Z_ADDREF_P(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
-               }
-               return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else {
-               zval *dim = opline->op2.zv;
-
-               zend_fetch_dimension_address_RW(&rv, container, dim, IS_CONST TSRMLS_CC);
-               value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-               ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
-               var_ptr = Z_INDIRECT(rv);
-       }
 
-       if (UNEXPECTED(var_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
-       }
+               zval *ptr = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
 
-       if (UNEXPECTED(var_ptr == &EG(error_zval))) {
-               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
+               if (Z_TYPE_P(ptr) == IS_LONG) {
+                       EG(exit_status) = Z_LVAL_P(ptr);
+               } else {
+                       zend_print_variable(ptr TSRMLS_CC);
                }
-       } else {
-               ZVAL_DEREF(var_ptr);
-               SEPARATE_ZVAL_NOREF(var_ptr);
-
-               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
 
-               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
-               }
        }
-
-       FREE_OP(free_op_data1);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_INC_OPCODE();
-       ZEND_VM_NEXT_OPCODE();
+#endif
+       zend_bailout();
+       ZEND_VM_NEXT_OPCODE(); /* Never reached */
 }
 
-static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_JMP_SET_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *var_ptr;
        zval *value;
+       int is_ref = 0;
 
        SAVE_OPLINE();
-       value = opline->op2.zv;
-       var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+       value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
+       if ((IS_CV == IS_VAR || IS_CV == IS_CV) && Z_ISREF_P(value)) {
+               is_ref = 1;
+               value = Z_REFVAL_P(value);
        }
+       if (i_zend_is_true(value TSRMLS_CC)) {
+               ZVAL_COPY_VALUE(EX_VAR(opline->result.var), value);
+               if (IS_CV == IS_CONST) {
+                       if (UNEXPECTED(Z_OPT_COPYABLE_P(value))) {
+                               zval_copy_ctor_func(EX_VAR(opline->result.var));
+                       }
+               } else if (IS_CV == IS_CV) {
+                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+               } else if (IS_CV == IS_VAR && is_ref) {
+                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
 
-       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
-               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
-               }
-       } else {
-               ZVAL_DEREF(var_ptr);
-               SEPARATE_ZVAL_NOREF(var_ptr);
-
-               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
-
-               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
                }
+               ZEND_VM_JMP(opline->op2.jmp_addr);
        }
 
-
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_ADD_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_COALESCE_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
+       zval *value;
+       int is_ref = 0;
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SUB_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       SAVE_OPLINE();
+       value = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       if ((IS_CV == IS_VAR || IS_CV == IS_CV) && Z_ISREF_P(value)) {
+               is_ref = 1;
+               value = Z_REFVAL_P(value);
        }
-}
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_MUL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       if (Z_TYPE_P(value) > IS_NULL) {
+               ZVAL_COPY_VALUE(EX_VAR(opline->result.var), value);
+               if (IS_CV == IS_CONST) {
+                       if (UNEXPECTED(Z_OPT_COPYABLE_P(value))) {
+                               zval_copy_ctor_func(EX_VAR(opline->result.var));
+                       }
+               } else if (IS_CV == IS_CV) {
+                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+               } else if (IS_CV == IS_VAR && is_ref) {
+                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               }
+               ZEND_VM_JMP(opline->op2.jmp_addr);
        }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_DIV_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_MOD_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_QM_ASSIGN_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
+       zval *value;
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       SAVE_OPLINE();
+       value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       if ((IS_CV == IS_VAR || IS_CV == IS_CV) && Z_ISREF_P(value)) {
+               ZVAL_COPY(EX_VAR(opline->result.var), Z_REFVAL_P(value));
+
+       } else {
+               ZVAL_COPY_VALUE(EX_VAR(opline->result.var), value);
+               if (IS_CV == IS_CONST) {
+                       if (UNEXPECTED(Z_OPT_COPYABLE_P(value))) {
+                               zval_copy_ctor_func(EX_VAR(opline->result.var));
+                       }
+               } else if (IS_CV == IS_CV) {
+                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+               }
        }
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_STRLEN_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zval *value;
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_CONCAT_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       SAVE_OPLINE();
+       value = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+       if (EXPECTED(Z_TYPE_P(value) == IS_STRING)) {
+               ZVAL_LONG(EX_VAR(opline->result.var), Z_STRLEN_P(value));
+       } else {
+               if (Z_TYPE_P(value) < IS_TRUE) {
+                       ZVAL_LONG(EX_VAR(opline->result.var), 0);
+               } else if (Z_TYPE_P(value) == IS_TRUE) {
+                       ZVAL_LONG(EX_VAR(opline->result.var), 1);
+               } else if (Z_TYPE_P(value) <= IS_DOUBLE) {
+                       zend_string *str = zval_get_string(value);
+                       ZVAL_LONG(EX_VAR(opline->result.var), str->len);
+                       zend_string_release(str);
+               } else if (Z_TYPE_P(value) == IS_OBJECT) {
+                       zend_string *str;
+                       zval tmp;
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+                       ZVAL_COPY(&tmp, value);
+                       if (parse_arg_object_to_str(&tmp, &str, IS_STRING TSRMLS_CC) == FAILURE) {
+                               goto strlen_error;
+                       }
+                       ZVAL_LONG(EX_VAR(opline->result.var), str->len);
+                       zval_dtor(&tmp);
+               } else {
+strlen_error:
+                       zend_error(E_WARNING, "strlen() expects parameter 1 to be string, %s given", zend_get_type_by_const(Z_TYPE_P(value)));
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
        }
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_OR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_TYPE_CHECK_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zval *value;
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+
+       SAVE_OPLINE();
+       value = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+       switch (opline->extended_value) {
+               case IS_NULL:
+               case IS_LONG:
+               case IS_DOUBLE:
+               case IS_STRING:
+               case IS_ARRAY:
+                       ZVAL_BOOL(EX_VAR(opline->result.var), Z_TYPE_P(value) == opline->extended_value);
+                       break;
+               case _IS_BOOL:
+                       ZVAL_BOOL(EX_VAR(opline->result.var), Z_TYPE_P(value) == IS_TRUE || Z_TYPE_P(value) == IS_FALSE);
+                       break;
+               case IS_OBJECT:
+                       if (Z_TYPE_P(value) == opline->extended_value) {
+                               zend_class_entry *ce = Z_OBJCE_P(value);
+                               if (ce->name->len == sizeof("__PHP_Incomplete_Class") - 1
+                                               && !strncmp(ce->name->val, "__PHP_Incomplete_Class", ce->name->len)) {
+                                       ZVAL_FALSE(EX_VAR(opline->result.var));
+                               } else {
+                                       ZVAL_TRUE(EX_VAR(opline->result.var));
+                               }
+                       } else {
+                               ZVAL_FALSE(EX_VAR(opline->result.var));
+                       }
+                       break;
+               case IS_RESOURCE:
+                       if (Z_TYPE_P(value) == opline->extended_value) {
+                               const char *type_name = zend_rsrc_list_get_rsrc_type(Z_RES_P(value) TSRMLS_CC);
+                               ZVAL_BOOL(EX_VAR(opline->result.var), type_name != NULL);
+                       } else {
+                               ZVAL_FALSE(EX_VAR(opline->result.var));
+                       }
+                       break;
+               EMPTY_SWITCH_DEFAULT_CASE()
        }
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_AND_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ADD_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       SAVE_OPLINE();
+       fast_add_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               opline->op2.zv TSRMLS_CC);
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SUB_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *object;
-       zval *property;
-       zval *retval;
-       zval *zptr;
 
        SAVE_OPLINE();
-       object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
-       property = opline->op2.zv;
-       retval = EX_VAR(opline->result.var);
-
-       if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
-       }
-
-       if (IS_CV != IS_UNUSED) {
-               object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
-       }
+       fast_sub_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               opline->op2.zv TSRMLS_CC);
 
-       if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
-               zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
 
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(retval);
-               }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
+static int ZEND_FASTCALL  ZEND_MUL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       /* here we are sure we are dealing with an object */
 
-       if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+       SAVE_OPLINE();
+       fast_mul_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               opline->op2.zv TSRMLS_CC);
 
-               ZVAL_DEREF(zptr);
-               SEPARATE_ZVAL_NOREF(zptr);
 
-               incdec_op(zptr);
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_COPY(retval, zptr);
-               }
-       } else {
-               zval rv;
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-               if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
-                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+static int ZEND_FASTCALL  ZEND_DIV_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
-                               zval rv;
-                               zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
 
-                               if (Z_REFCOUNT_P(z) == 0) {
-                                       zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
-                               }
-                               ZVAL_COPY_VALUE(z, value);
-                       }
-                       if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
-                       SEPARATE_ZVAL_IF_NOT_REF(z);
-                       incdec_op(z);
-                       ZVAL_COPY_VALUE(retval, z);
-                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
-                       SELECTIVE_PZVAL_LOCK(retval, opline);
-                       zval_ptr_dtor(z);
-               } else {
-                       zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-                       if (RETURN_VALUE_USED(opline)) {
-                               ZVAL_NULL(retval);
-                       }
-               }
-       }
+       SAVE_OPLINE();
+       fast_div_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               opline->op2.zv TSRMLS_CC);
 
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_PRE_INC_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_pre_incdec_property_helper_SPEC_CV_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_pre_incdec_property_helper_SPEC_CV_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_MOD_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *object;
-       zval *property;
-       zval *retval;
-       zval *zptr;
 
        SAVE_OPLINE();
-       object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
-       property = opline->op2.zv;
-       retval = EX_VAR(opline->result.var);
-
-       if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
-       }
-
-       if (IS_CV != IS_UNUSED) {
-               object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
-       }
-
-       if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
-               zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+       fast_mod_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               opline->op2.zv TSRMLS_CC);
 
-               ZVAL_NULL(retval);
 
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       /* here we are sure we are dealing with an object */
+static int ZEND_FASTCALL  ZEND_SL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
 
-               ZVAL_DEREF(zptr);
-               ZVAL_COPY_VALUE(retval, zptr);
-               zval_opt_copy_ctor(zptr);
+       SAVE_OPLINE();
+       shift_left_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               opline->op2.zv TSRMLS_CC);
 
-               incdec_op(zptr);
-       } else {
-               if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
-                       zval rv;
-                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
-                       zval z_copy;
 
-                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
-                               zval rv;
-                               zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-                               if (Z_REFCOUNT_P(z) == 0) {
-                                       zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
-                               }
-                               ZVAL_COPY_VALUE(z, value);
-                       }
-                       ZVAL_DUP(retval, z);
-                       ZVAL_DUP(&z_copy, z);
-                       incdec_op(&z_copy);
-                       if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
-                       Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
-                       zval_ptr_dtor(&z_copy);
-                       zval_ptr_dtor(z);
-               } else {
-                       zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-                       ZVAL_NULL(retval);
-               }
-       }
+static int ZEND_FASTCALL  ZEND_SR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+
+       SAVE_OPLINE();
+       shift_right_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               opline->op2.zv TSRMLS_CC);
 
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_POST_INC_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_post_incdec_property_helper_SPEC_CV_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+       USE_OPLINE
 
-static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_post_incdec_property_helper_SPEC_CV_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+
+       SAVE_OPLINE();
+       concat_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               opline->op2.zv TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CV_CONST(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *varname;
-       zval *retval;
-       zend_string *name;
-       HashTable *target_symbol_table;
 
        SAVE_OPLINE();
-       varname = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-
-       if (IS_CV == IS_CONST) {
-               name = Z_STR_P(varname);
-       } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
-               name = Z_STR_P(varname);
-               zend_string_addref(name);
-       } else {
-               name = zval_get_string(varname);
-       }
+       fast_is_identical_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               opline->op2.zv TSRMLS_CC);
 
-       if (IS_CONST != IS_UNUSED) {
-               zend_class_entry *ce;
 
-               if (IS_CONST == IS_CONST) {
-                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                       } else {
-                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                               if (UNEXPECTED(ce == NULL)) {
-                                       if (IS_CV != IS_CONST) {
-                                               zend_string_release(name);
-                                       }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-                                       CHECK_EXCEPTION();
-                                       ZEND_VM_NEXT_OPCODE();
-                               }
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
-                       }
-               } else {
-                       ce = Z_CE_P(EX_VAR(opline->op2.var));
-               }
-               retval = zend_std_get_static_property(ce, name, 0, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       } else {
-               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-               retval = zend_hash_find(target_symbol_table, name);
-               if (retval == NULL) {
-                       switch (type) {
-                               case BP_VAR_R:
-                               case BP_VAR_UNSET:
-                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                       /* break missing intentionally */
-                               case BP_VAR_IS:
-                                       retval = &EG(uninitialized_zval);
-                                       break;
-                               case BP_VAR_RW:
-                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                       /* break missing intentionally */
-                               case BP_VAR_W:
-                                       retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
-                                       break;
-                               EMPTY_SWITCH_DEFAULT_CASE()
-                       }
-               /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
-               } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
-                       retval = Z_INDIRECT_P(retval);
-                       if (Z_TYPE_P(retval) == IS_UNDEF) {
-                               switch (type) {
-                                       case BP_VAR_R:
-                                       case BP_VAR_UNSET:
-                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                               /* break missing intentionally */
-                                       case BP_VAR_IS:
-                                               retval = &EG(uninitialized_zval);
-                                               break;
-                                       case BP_VAR_RW:
-                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                               /* break missing intentionally */
-                                       case BP_VAR_W:
-                                               ZVAL_NULL(retval);
-                                               break;
-                                       EMPTY_SWITCH_DEFAULT_CASE()
-                               }
-                       }
-               }
-               if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
-                       if (Z_CONSTANT_P(retval)) {
-                               zval_update_constant(retval, 1 TSRMLS_CC);
-                       }
-               } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
+       zval *result = EX_VAR(opline->result.var);
 
-               }
-       }
+       SAVE_OPLINE();
+       fast_is_not_identical_function(result,
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               opline->op2.zv TSRMLS_CC);
 
-       if (IS_CV != IS_CONST) {
-               zend_string_release(name);
-       }
 
-       ZEND_ASSERT(retval != NULL);
-       if (type == BP_VAR_R || type == BP_VAR_IS) {
-               if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
-                       ZVAL_UNREF(retval);
-               }
-               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-       } else {
-               ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
-       }
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_R_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+       USE_OPLINE
 
-static int ZEND_FASTCALL  ZEND_FETCH_W_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+       zval *result = EX_VAR(opline->result.var);
 
-static int ZEND_FASTCALL  ZEND_FETCH_RW_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       SAVE_OPLINE();
+       fast_equal_function(result,
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               opline->op2.zv TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_FUNC_ARG_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-               return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else {
-               return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
+       zval *result = EX_VAR(opline->result.var);
+
+       SAVE_OPLINE();
+       fast_not_equal_function(result,
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               opline->op2.zv TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_UNSET_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       USE_OPLINE
+
+       zval *result = EX_VAR(opline->result.var);
+
+       SAVE_OPLINE();
+       fast_is_smaller_function(result,
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               opline->op2.zv TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_IS_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       USE_OPLINE
+
+       zval *result = EX_VAR(opline->result.var);
+
+       SAVE_OPLINE();
+       fast_is_smaller_or_equal_function(result,
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               opline->op2.zv TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *container;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-       zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+       bitwise_or_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               opline->op2.zv TSRMLS_CC);
 
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
-       zval *container;
 
-       SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-       }
-       ZVAL_DEREF(container);
-       zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+       SAVE_OPLINE();
+       bitwise_and_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               opline->op2.zv TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-       }
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
-       zval *container;
 
-       SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-       }
-       ZVAL_DEREF(container);
-       zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+       SAVE_OPLINE();
+       bitwise_xor_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               opline->op2.zv TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-       }
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *container;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
-       zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+       boolean_xor_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               opline->op2.zv TSRMLS_CC);
 
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *container;
-       zend_free_op free_op1;
+       zend_free_op free_op_data1;
+       zval *object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+       zval *property = opline->op2.zv;
+       zval *value;
+       zval *zptr;
 
-       SAVE_OPLINE();
+       if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+       }
 
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-        if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
-            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
-        }
-               container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-               }
-               ZVAL_DEREF(container);
-               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
-               if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-               }
+       if (IS_CV != IS_UNUSED) {
+               object = make_real_object(object TSRMLS_CC);
+       }
 
+       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
 
-       } else {
-               if (IS_CONST == IS_UNUSED) {
-                       zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
+       if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+               zend_error(E_WARNING, "Attempt to assign property of non-object");
+
+               FREE_OP(free_op_data1);
+
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
                }
-               container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+       } else {
+               /* here we are sure we are dealing with an object */
+               if (opline->extended_value == ZEND_ASSIGN_OBJ
+                       && EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+                       && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+
+                       ZVAL_DEREF(zptr);
+                       SEPARATE_ZVAL_NOREF(zptr);
+
+                       binary_op(zptr, zptr, value TSRMLS_CC);
+                       if (RETURN_VALUE_USED(opline)) {
+                               ZVAL_COPY(EX_VAR(opline->result.var), zptr);
+                       }
+               } else {
+                       zval *z = NULL;
+                       zval rv;
+
+                       if (opline->extended_value == ZEND_ASSIGN_OBJ) {
+                               if (Z_OBJ_HT_P(object)->read_property) {
+                                       z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+                               }
+                       } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
+                               if (Z_OBJ_HT_P(object)->read_dimension) {
+                                       z = Z_OBJ_HT_P(object)->read_dimension(object, property, BP_VAR_R, &rv TSRMLS_CC);
+                               }
+                       }
+                       if (z) {
+                               if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                                       zval rv;
+                                       zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
 
+                                       if (Z_REFCOUNT_P(z) == 0) {
+                                               zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
+                                       }
+                                       ZVAL_COPY_VALUE(z, value);
+                               }
+//???                          if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
+                               SEPARATE_ZVAL_IF_NOT_REF(z);
+                               binary_op(z, z, value TSRMLS_CC);
+                               if (opline->extended_value == ZEND_ASSIGN_OBJ) {
+                                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+                               } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
+                                       Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
+                               }
+                               if (RETURN_VALUE_USED(opline)) {
+                                       ZVAL_COPY(EX_VAR(opline->result.var), z);
+                               }
+                               zval_ptr_dtor(z);
+                       } else {
+                               zend_error(E_WARNING, "Attempt to assign property of non-object");
+                               if (RETURN_VALUE_USED(opline)) {
+                                       ZVAL_NULL(EX_VAR(opline->result.var));
+                               }
+                       }
+               }
 
+               FREE_OP(free_op_data1);
        }
+
+       /* assign_obj has two opcodes! */
        CHECK_EXCEPTION();
+       ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_UNSET_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_CV_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
-       zval *container;
+       zend_free_op free_op_data1;
+       zval *var_ptr, rv;
+       zval *value, *container;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
-
+       container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
        if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       ZVAL_DEREF(container);
-       zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+       if (IS_CV != IS_UNUSED) {
+               ZVAL_DEREF(container);
+       }
+       if (IS_CV == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+               if (IS_CV == IS_VAR && !0) {
+                       Z_ADDREF_P(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
+               }
+               return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else {
+               zval *dim = opline->op2.zv;
 
-       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+               zend_fetch_dimension_address_RW(&rv, container, dim, IS_CONST TSRMLS_CC);
+               value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+               ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+               var_ptr = Z_INDIRECT(rv);
        }
 
+       if (UNEXPECTED(var_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
+       }
+
+       if (UNEXPECTED(var_ptr == &EG(error_zval))) {
+               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
+       } else {
+               ZVAL_DEREF(var_ptr);
+               SEPARATE_ZVAL_NOREF(var_ptr);
+
+               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
+
+               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+               }
+       }
+
+       FREE_OP(free_op_data1);
+
        CHECK_EXCEPTION();
+       ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *container;
-
-       zval *offset;
+       zval *var_ptr;
+       zval *value;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-       offset  = opline->op2.zv;
-
-       if ((IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
-           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
-               zend_error(E_NOTICE, "Trying to get property of non-object");
-               ZVAL_NULL(EX_VAR(opline->result.var));
-       } else {
-               zval *retval;
+       value = opline->op2.zv;
+       var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
 
-               /* here we are sure we are dealing with an object */
-               do {
-                       if (IS_CONST == IS_CONST &&
-                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
-                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
-                               zend_object *zobj = Z_OBJ_P(container);
+       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
+       }
 
-                               if (EXPECTED(prop_info)) {
-                                       retval = OBJ_PROP(zobj, prop_info->offset);
-                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               } else if (EXPECTED(zobj->properties != NULL)) {
-                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
-                                       if (EXPECTED(retval)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               }
-                       }
+       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
+       } else {
+               ZVAL_DEREF(var_ptr);
+               SEPARATE_ZVAL_NOREF(var_ptr);
 
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
 
-                       if (retval != EX_VAR(opline->result.var)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                       }
-               } while (0);
+               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+               }
        }
 
 
@@ -35116,737 +29271,653 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HAN
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_ADD_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
+
+static int ZEND_FASTCALL  ZEND_ASSIGN_SUB_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
+
+static int ZEND_FASTCALL  ZEND_ASSIGN_MUL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
+
+static int ZEND_FASTCALL  ZEND_ASSIGN_DIV_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
+
+static int ZEND_FASTCALL  ZEND_ASSIGN_MOD_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
-       zval *property;
-       zval *container;
 
-       SAVE_OPLINE();
-       property = opline->op2.zv;
-
-       container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
+}
 
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+static int ZEND_FASTCALL  ZEND_ASSIGN_SL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_SR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
-       zval *property;
-       zval *container;
-
-       SAVE_OPLINE();
-       property = opline->op2.zv;
-       container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
-
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
-       }
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_CONCAT_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *container;
-
-       zval *offset;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
-       offset  = opline->op2.zv;
-
-       if ((IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
-           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
-               ZVAL_NULL(EX_VAR(opline->result.var));
-       } else {
-               zval *retval;
-
-               /* here we are sure we are dealing with an object */
-               do {
-                       if (IS_CONST == IS_CONST &&
-                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
-                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
-                               zend_object *zobj = Z_OBJ_P(container);
-
-                               if (EXPECTED(prop_info)) {
-                                       retval = OBJ_PROP(zobj, prop_info->offset);
-                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               } else if (EXPECTED(zobj->properties != NULL)) {
-                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
-                                       if (EXPECTED(retval)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               }
-                       }
-
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
-
-                       if (retval != EX_VAR(opline->result.var)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                       }
-               } while (0);
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
-
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_OR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *container;
 
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-               /* Behave like FETCH_OBJ_W */
-               zend_free_op free_op1;
-               zval *property;
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
 
-               SAVE_OPLINE();
-               property = opline->op2.zv;
-               container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_AND_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-        if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
-            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
-        }
-               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
-               }
-               zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
 
-               if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-               }
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       } else {
-               return ZEND_FETCH_OBJ_R_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
-       zval *container, *property;
+
+       zval *object;
+       zval *property;
+       zval *retval;
+       zval *zptr;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
+       object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
        property = opline->op2.zv;
+       retval = EX_VAR(opline->result.var);
 
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+       if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+       if (IS_CV != IS_UNUSED) {
+               object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
        }
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+       if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+               zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
 
-static int ZEND_FASTCALL  ZEND_FETCH_LIST_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_NULL(retval);
+               }
 
-       zval *container;
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
+       }
 
-       SAVE_OPLINE();
-       container = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+       /* here we are sure we are dealing with an object */
 
-       if (EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
+       if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
 
-               zval *value = zend_fetch_dimension_address_inner(Z_ARRVAL_P(container), opline->op2.zv, IS_CONST, BP_VAR_R TSRMLS_CC);
+               ZVAL_DEREF(zptr);
+               SEPARATE_ZVAL_NOREF(zptr);
 
-               ZVAL_COPY(EX_VAR(opline->result.var), value);
-       } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT) &&
-                  EXPECTED(Z_OBJ_HT_P(container)->read_dimension)) {
-               zval *result = EX_VAR(opline->result.var);
-               zval *retval = Z_OBJ_HT_P(container)->read_dimension(container, opline->op2.zv, BP_VAR_R, result TSRMLS_CC);
+               incdec_op(zptr);
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_COPY(retval, zptr);
+               }
+       } else {
+               zval rv;
 
-               if (retval) {
-                       if (result != retval) {
-                               ZVAL_COPY(result, retval);
+               if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
+                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
+                               zval rv;
+                               zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+
+                               if (Z_REFCOUNT_P(z) == 0) {
+                                       zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
+                               }
+                               ZVAL_COPY_VALUE(z, value);
                        }
+                       if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
+                       SEPARATE_ZVAL_IF_NOT_REF(z);
+                       incdec_op(z);
+                       ZVAL_COPY_VALUE(retval, z);
+                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+                       SELECTIVE_PZVAL_LOCK(retval, opline);
+                       zval_ptr_dtor(z);
                } else {
-                       ZVAL_NULL(result);
+                       zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+                       if (RETURN_VALUE_USED(opline)) {
+                               ZVAL_NULL(retval);
+                       }
                }
-       } else {
-               ZVAL_NULL(EX_VAR(opline->result.var));
        }
+
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_PRE_INC_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_pre_incdec_property_helper_SPEC_CV_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_pre_incdec_property_helper_SPEC_CV_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        zval *object;
-       zval *property_name;
+       zval *property;
+       zval *retval;
+       zval *zptr;
 
        SAVE_OPLINE();
-       object = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-       property_name = opline->op2.zv;
+       object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+       property = opline->op2.zv;
+       retval = EX_VAR(opline->result.var);
 
        if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
-       zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
-
-
-       /* assign_obj has two opcodes! */
-       CHECK_EXCEPTION();
-       ZEND_VM_INC_OPCODE();
-       ZEND_VM_NEXT_OPCODE();
-}
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       if (IS_CV != IS_UNUSED) {
+               object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
+       }
 
-       zval *object_ptr;
+       if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+               zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
 
-       SAVE_OPLINE();
-       object_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+               ZVAL_NULL(retval);
 
-       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
        }
-       ZVAL_DEREF(object_ptr);
-       if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
 
-               zval *property_name = opline->op2.zv;
+       /* here we are sure we are dealing with an object */
 
-               zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+       if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
 
-       } else {
-               zend_free_op free_op_data1;
-               zval  rv;
-               zval *value;
-               zval *dim = opline->op2.zv;
-               zval *variable_ptr;
+               ZVAL_DEREF(zptr);
+               ZVAL_COPY_VALUE(retval, zptr);
+               zval_opt_copy_ctor(zptr);
 
-               if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
-                   EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
-                       zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
+               incdec_op(zptr);
+       } else {
+               if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
+                       zval rv;
+                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+                       zval z_copy;
 
-                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-                       zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
-                       FREE_OP(free_op_data1);
-               } else {
-                       zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_CONST TSRMLS_CC);
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
+                               zval rv;
+                               zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
 
-                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-                       ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
-                       variable_ptr = Z_INDIRECT(rv);
-                       if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
-                               FREE_OP(free_op_data1);
-                               if (RETURN_VALUE_USED(opline)) {
-                                       ZVAL_NULL(EX_VAR(opline->result.var));
-                               }
-                       } else {
-                               value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
-                               if ((opline+1)->op1_type == IS_VAR) {
-                                       FREE_OP(free_op_data1);
-                               }
-                               if (RETURN_VALUE_USED(opline)) {
-                                       ZVAL_COPY(EX_VAR(opline->result.var), value);
+                               if (Z_REFCOUNT_P(z) == 0) {
+                                       zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
                                }
+                               ZVAL_COPY_VALUE(z, value);
                        }
+                       ZVAL_DUP(retval, z);
+                       ZVAL_DUP(&z_copy, z);
+                       incdec_op(&z_copy);
+                       if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
+                       Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+                       zval_ptr_dtor(&z_copy);
+                       zval_ptr_dtor(z);
+               } else {
+                       zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+                       ZVAL_NULL(retval);
                }
        }
 
-       /* assign_dim has two opcodes! */
+
        CHECK_EXCEPTION();
-       ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_POST_INC_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       USE_OPLINE
-
-       zval *value;
-       zval *variable_ptr;
-
-       SAVE_OPLINE();
-       value = opline->op2.zv;
-       variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-
-       if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
-               if (IS_CONST == IS_TMP_VAR) {
-
-               }
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
-               }
-       } else {
-               value = zend_assign_to_variable(variable_ptr, value, IS_CONST TSRMLS_CC);
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_COPY(EX_VAR(opline->result.var), value);
-               }
-
-       }
-
-       /* zend_assign_to_variable() always takes care of op2, never free it! */
+       return zend_post_incdec_property_helper_SPEC_CV_CONST(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_post_incdec_property_helper_SPEC_CV_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CV_CONST(int type, ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *function_name;
 
-       zval *object;
-       zend_function *fbc;
-       zend_class_entry *called_scope;
-       zend_object *obj;
+       zval *varname;
+       zval *retval;
+       zend_string *name;
+       HashTable *target_symbol_table;
 
        SAVE_OPLINE();
+       varname = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
 
-       function_name = opline->op2.zv;
-
-       if (IS_CONST != IS_CONST &&
-           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       HANDLE_EXCEPTION();
-               }
-               zend_error_noreturn(E_ERROR, "Method name must be a string");
+       if (IS_CV == IS_CONST) {
+               name = Z_STR_P(varname);
+       } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
+               name = Z_STR_P(varname);
+               zend_string_addref(name);
+       } else {
+               name = zval_get_string(varname);
        }
 
-       object = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-
-       if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
-               uint32_t nesting = 1;
-
-               if (UNEXPECTED(EG(exception) != NULL)) {
-
-                       HANDLE_EXCEPTION();
-               }
-
-               zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s",  Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
+       if (IS_CONST != IS_UNUSED) {
+               zend_class_entry *ce;
 
+               if (IS_CONST == IS_CONST) {
+                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+                       } else {
+                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+                               if (UNEXPECTED(ce == NULL)) {
+                                       if (IS_CV != IS_CONST) {
+                                               zend_string_release(name);
+                                       }
 
-               if (EG(exception) != NULL) {
-                       HANDLE_EXCEPTION();
+                                       CHECK_EXCEPTION();
+                                       ZEND_VM_NEXT_OPCODE();
+                               }
+                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+                       }
+               } else {
+                       ce = Z_CE_P(EX_VAR(opline->op2.var));
                }
+               retval = zend_std_get_static_property(ce, name, 0, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
 
-               /* No exception raised: Skip over arguments until fcall opcode with correct
-                * nesting level. Return NULL (except when return value unused) */
-               do {
-                       opline++;
-                       if (opline->opcode == ZEND_INIT_FCALL ||
-                               opline->opcode == ZEND_INIT_FCALL_BY_NAME ||
-                               opline->opcode == ZEND_INIT_NS_FCALL_BY_NAME ||
-                               opline->opcode == ZEND_INIT_METHOD_CALL ||
-                               opline->opcode == ZEND_INIT_STATIC_METHOD_CALL ||
-                               opline->opcode == ZEND_INIT_USER_CALL ||
-                               opline->opcode == ZEND_NEW
-                       ) {
-                               nesting++;
-                       } else if (opline->opcode == ZEND_DO_FCALL) {
-                               nesting--;
+       } else {
+               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+               retval = zend_hash_find(target_symbol_table, name);
+               if (retval == NULL) {
+                       switch (type) {
+                               case BP_VAR_R:
+                               case BP_VAR_UNSET:
+                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                       /* break missing intentionally */
+                               case BP_VAR_IS:
+                                       retval = &EG(uninitialized_zval);
+                                       break;
+                               case BP_VAR_RW:
+                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                       /* break missing intentionally */
+                               case BP_VAR_W:
+                                       retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
+                                       break;
+                               EMPTY_SWITCH_DEFAULT_CASE()
+                       }
+               /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
+               } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
+                       retval = Z_INDIRECT_P(retval);
+                       if (Z_TYPE_P(retval) == IS_UNDEF) {
+                               switch (type) {
+                                       case BP_VAR_R:
+                                       case BP_VAR_UNSET:
+                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                               /* break missing intentionally */
+                                       case BP_VAR_IS:
+                                               retval = &EG(uninitialized_zval);
+                                               break;
+                                       case BP_VAR_RW:
+                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                               /* break missing intentionally */
+                                       case BP_VAR_W:
+                                               ZVAL_NULL(retval);
+                                               break;
+                                       EMPTY_SWITCH_DEFAULT_CASE()
+                               }
                        }
-               } while (nesting);
+               }
+               if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
+                       if (Z_CONSTANT_P(retval)) {
+                               zval_update_constant(retval, 1 TSRMLS_CC);
+                       }
+               } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
 
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
                }
+       }
 
-               /* We've skipped EXT_FCALL_BEGIND, so also skip the ending opcode */
-               if ((opline + 1)->opcode == ZEND_EXT_FCALL_END) {
-                       opline++;
+       if (IS_CV != IS_CONST) {
+               zend_string_release(name);
+       }
+
+       ZEND_ASSERT(retval != NULL);
+       if (type == BP_VAR_R || type == BP_VAR_IS) {
+               if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
+                       ZVAL_UNREF(retval);
                }
-               ZEND_VM_JMP(++opline);
+               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+       } else {
+               ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
        }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       obj = Z_OBJ_P(object);
-       called_scope = obj->ce;
+static int ZEND_FASTCALL  ZEND_FETCH_R_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
 
-       if (IS_CONST != IS_CONST ||
-           EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
-           zend_object *orig_obj = obj;
+static int ZEND_FASTCALL  ZEND_FETCH_W_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
 
-               if (UNEXPECTED(obj->handlers->get_method == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Object does not support method calls");
-               }
+static int ZEND_FASTCALL  ZEND_FETCH_RW_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
 
-               /* First, locate the function. */
-               fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_CONST == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
-               if (UNEXPECTED(fbc == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
-               }
-               if (IS_CONST == IS_CONST &&
-                   EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
-                   EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
-                   EXPECTED(obj == orig_obj)) {
-                       CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope, fbc);
-               }
-       }
+static int ZEND_FASTCALL  ZEND_FETCH_FUNC_ARG_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_STATIC) != 0)) {
-               obj = NULL;
+       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+               return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else {
-               GC_REFCOUNT(obj)++; /* For $this pointer */
+               return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
+}
 
-       EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
-               fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
-
+static int ZEND_FASTCALL  ZEND_FETCH_UNSET_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+static int ZEND_FASTCALL  ZEND_FETCH_IS_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_CV_CONST(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_CASE_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *result = EX_VAR(opline->result.var);
+       zval *container;
 
        SAVE_OPLINE();
-       fast_equal_function(result,
-                _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-                opline->op2.zv TSRMLS_CC);
+       container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+       zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
-       zval *expr_ptr, new_expr;
+       zend_free_op free_op1;
+       zval *container;
 
        SAVE_OPLINE();
-       if ((IS_CV == IS_VAR || IS_CV == IS_CV) &&
-           (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
-               expr_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-               if (IS_CV == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
-               }
-               ZVAL_MAKE_REF(expr_ptr);
-               Z_ADDREF_P(expr_ptr);
-
-       } else {
-               expr_ptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-               if (IS_CV == IS_TMP_VAR) {
-                       ZVAL_COPY_VALUE(&new_expr, expr_ptr);
-                       expr_ptr = &new_expr;
-               } else if (IS_CV == IS_CONST) {
-                       if (!Z_IMMUTABLE_P(expr_ptr)) {
-                               ZVAL_DUP(&new_expr, expr_ptr);
-                               expr_ptr = &new_expr;
-                       }
-               } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(expr_ptr)) {
-                       expr_ptr = Z_REFVAL_P(expr_ptr);
-                       if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
+       container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
 
-               } else if (IS_CV == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
-                       Z_ADDREF_P(expr_ptr);
-               }
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
+       ZVAL_DEREF(container);
+       zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
 
-       if (IS_CONST != IS_UNUSED) {
-
-               zval *offset = opline->op2.zv;
-               zend_string *str;
-               zend_ulong hval;
-
-add_again:
-               switch (Z_TYPE_P(offset)) {
-                       case IS_DOUBLE:
-                               hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                               goto num_index;
-                       case IS_LONG:
-                               hval = Z_LVAL_P(offset);
-num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
-                               break;
-                       case IS_STRING:
-                               str = Z_STR_P(offset);
-                               if (IS_CONST != IS_CONST) {
-                                       if (ZEND_HANDLE_NUMERIC(str, hval)) {
-                                               goto num_index;
-                                       }
-                               }
-str_index:
-                               zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
-                               break;
-                       case IS_NULL:
-                               str = STR_EMPTY_ALLOC();
-                               goto str_index;
-                       case IS_FALSE:
-                               hval = 0;
-                               goto num_index;
-                       case IS_TRUE:
-                               hval = 1;
-                               goto num_index;
-                       case IS_REFERENCE:
-                               offset = Z_REFVAL_P(offset);
-                               goto add_again;
-                               break;
-                       default:
-                               zend_error(E_WARNING, "Illegal offset type");
-                               zval_ptr_dtor(expr_ptr);
-                               /* do nothing */
-                               break;
-               }
-
-       } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
+       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zval *array;
-       uint32_t size;
        USE_OPLINE
+       zend_free_op free_op1;
+       zval *container;
 
-       array = EX_VAR(opline->result.var);
-       if (IS_CV != IS_UNUSED) {
-               size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
-       } else {
-               size = 0;
-       }
-       ZVAL_NEW_ARR(array);
-       zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
+       SAVE_OPLINE();
+       container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
 
-       if (IS_CV != IS_UNUSED) {
-               /* Explicitly initialize array as not-packed if flag is set */
-               if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
-                       zend_hash_real_init(Z_ARRVAL_P(array), 0);
-               }
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
+       ZVAL_DEREF(container);
+       zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
 
-       if (IS_CV == IS_UNUSED) {
-               ZEND_VM_NEXT_OPCODE();
-#if 0 || IS_CV != IS_UNUSED
-       } else {
-               return ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-#endif
+       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval tmp, *varname;
-       HashTable *target_symbol_table;
 
+       zval *container;
 
        SAVE_OPLINE();
-       if (IS_CV == IS_CV &&
-           IS_CONST == IS_UNUSED &&
-           (opline->extended_value & ZEND_QUICK_SET)) {
-               zval *var = EX_VAR(opline->op1.var);
+       container = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
+       zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
 
-               if (Z_REFCOUNTED_P(var)) {
-                       zend_refcounted *garbage = Z_COUNTED_P(var);
 
-                       if (!--GC_REFCOUNT(garbage)) {
-                               ZVAL_UNDEF(var);
-                               _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
-                       } else {
-                               GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
-                               ZVAL_UNDEF(var);
-                       }
-               } else {
-                       ZVAL_UNDEF(var);
-               }
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       varname = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zval *container;
+       zend_free_op free_op1;
 
-       ZVAL_UNDEF(&tmp);
-       if (IS_CV != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-               ZVAL_STR(&tmp, zval_get_string(varname));
-               varname = &tmp;
-       }
+       SAVE_OPLINE();
 
-       if (IS_CONST != IS_UNUSED) {
-               zend_class_entry *ce;
+       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+        if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
+            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+        }
+               container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+               }
+               ZVAL_DEREF(container);
+               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
+               if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+               }
 
-               if (IS_CONST == IS_CONST) {
-                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                       } else {
-                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                               if (UNEXPECTED(EG(exception) != NULL)) {
-                                       if (IS_CV != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-                                               zend_string_release(Z_STR(tmp));
-                                       }
 
-                                       HANDLE_EXCEPTION();
-                               }
-                               if (UNEXPECTED(ce == NULL)) {
-                                       zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
-                               }
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
-                       }
-               } else {
-                       ce = Z_CE_P(EX_VAR(opline->op2.var));
-               }
-               zend_std_unset_static_property(ce, Z_STR_P(varname), ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
        } else {
-               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-               zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
-       }
+               if (IS_CONST == IS_UNUSED) {
+                       zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
+               }
+               container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
 
-       if (IS_CV != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-               zend_string_release(Z_STR(tmp));
-       }
 
+       }
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_UNSET_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
+       zend_free_op free_op1;
        zval *container;
-       zval *offset;
-       zend_ulong hval;
 
        SAVE_OPLINE();
        container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
+
        if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
-       }
-       if (IS_CV != IS_UNUSED) {
-               ZVAL_DEREF(container);
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       SEPARATE_ZVAL_NOREF(container);
-       offset = opline->op2.zv;
-
-       if (IS_CV != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
-               HashTable *ht = Z_ARRVAL_P(container);
-offset_again:
-               switch (Z_TYPE_P(offset)) {
-                       case IS_DOUBLE:
-                               hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                               zend_hash_index_del(ht, hval);
-                               break;
-                       case IS_LONG:
-                               hval = Z_LVAL_P(offset);
-num_index_dim:
-                               zend_hash_index_del(ht, hval);
-                               break;
-                       case IS_STRING:
-                               if (IS_CONST != IS_CONST) {
-                                       if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
-                                               goto num_index_dim;
-                                       }
-                               }
-                               if (ht == &EG(symbol_table).ht) {
-                                       zend_delete_global_variable(Z_STR_P(offset) TSRMLS_CC);
-                               } else {
-                                       zend_hash_del(ht, Z_STR_P(offset));
-                               }
-                               break;
-                       case IS_NULL:
-                               zend_hash_del(ht, STR_EMPTY_ALLOC());
-                               break;
-                       case IS_FALSE:
-                               hval = 0;
-                               goto num_index_dim;
-                       case IS_TRUE:
-                               hval = 1;
-                               goto num_index_dim;
-                       case IS_RESOURCE:
-                               hval = Z_RES_HANDLE_P(offset);
-                               goto num_index_dim;
-                       case IS_REFERENCE:
-                               offset = Z_REFVAL_P(offset);
-                               goto offset_again;
-                               break;
-                       default:
-                               zend_error(E_WARNING, "Illegal offset type in unset");
-                               break;
-               }
-
-       } else if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use object as array");
-               }
-//???          if (IS_CONST == IS_CONST) {
-//???                  zval_copy_ctor(offset);
-//???          }
-               Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
-
-       } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
-               ZEND_VM_CONTINUE(); /* bailed out before */
-       } else {
+       ZVAL_DEREF(container);
+       zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, opline->op2.zv, IS_CONST TSRMLS_CC);
 
+       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        zval *container;
+
        zval *offset;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
-       }
-       offset = opline->op2.zv;
+       container = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+       offset  = opline->op2.zv;
 
-       if (IS_CV != IS_UNUSED) {
-               ZVAL_DEREF(container);
-       }
-       if (IS_CV == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
-               if (Z_OBJ_HT_P(container)->unset_property) {
-                       Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
-               } else {
-                       zend_error(E_NOTICE, "Trying to unset property of non-object");
-               }
+       if ((IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               zend_error(E_NOTICE, "Trying to get property of non-object");
+               ZVAL_NULL(EX_VAR(opline->result.var));
+       } else {
+               zval *retval;
+
+               /* here we are sure we are dealing with an object */
+               do {
+                       if (IS_CONST == IS_CONST &&
+                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
+                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
+                               zend_object *zobj = Z_OBJ_P(container);
+
+                               if (EXPECTED(prop_info)) {
+                                       retval = OBJ_PROP(zobj, prop_info->offset);
+                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
+                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                                               break;
+                                       }
+                               } else if (EXPECTED(zobj->properties != NULL)) {
+                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
+                                       if (EXPECTED(retval)) {
+                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                                               break;
+                                       }
+                               }
+                       }
+
+                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+
+                       if (retval != EX_VAR(opline->result.var)) {
+                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                       }
+               } while (0);
        }
 
 
@@ -35854,1488 +29925,1443 @@ static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDL
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *value;
+       zend_free_op free_op1;
+       zval *property;
+       zval *container;
 
        SAVE_OPLINE();
-       if (IS_CV == IS_CV &&
-           IS_CONST == IS_UNUSED &&
-           (opline->extended_value & ZEND_QUICK_SET)) {
-               value = EX_VAR(opline->op1.var);
-               if (opline->extended_value & ZEND_ISSET) {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               !i_zend_is_true(value TSRMLS_CC));
-                       CHECK_EXCEPTION();
-               }
-               ZEND_VM_NEXT_OPCODE();
-       } else {
-
-               zval tmp, *varname = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
+       property = opline->op2.zv;
 
-               ZVAL_UNDEF(&tmp);
-               if (IS_CV != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-                       ZVAL_STR(&tmp, zval_get_string(varname));
-                       varname = &tmp;
-               }
+       container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+       }
 
-               if (IS_CONST != IS_UNUSED) {
-                       zend_class_entry *ce;
+       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
 
-                       if (IS_CONST == IS_CONST) {
-                               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                                       ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                               } else {
-                                       ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                                       if (UNEXPECTED(ce == NULL)) {
-                                               CHECK_EXCEPTION();
-                                               ZEND_VM_NEXT_OPCODE();
-                                       }
-                                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
-                               }
-                       } else {
-                               ce = Z_CE_P(EX_VAR(opline->op2.var));
-                       }
-                       value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
-               } else {
-                       HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-                       value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
-               }
+       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+       }
 
-               if (IS_CV != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-                       zend_string_release(Z_STR(tmp));
-               }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-               if (opline->extended_value & ZEND_ISSET) {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               value && Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               !value || !i_zend_is_true(value TSRMLS_CC));
-               }
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *property;
+       zval *container;
 
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
+       SAVE_OPLINE();
+       property = opline->op2.zv;
+       container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+       }
+       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
+
+       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        zval *container;
-       int result;
-       zend_ulong hval;
+
        zval *offset;
 
        SAVE_OPLINE();
        container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
-       offset = opline->op2.zv;
+       offset  = opline->op2.zv;
 
-       if (IS_CV != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
-               HashTable *ht = Z_ARRVAL_P(container);
-               zval *value;
-               zend_string *str;
+       if ((IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               ZVAL_NULL(EX_VAR(opline->result.var));
+       } else {
+               zval *retval;
 
-isset_again:
-               if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
-                       str = Z_STR_P(offset);
-                       if (IS_CONST != IS_CONST) {
-                               if (ZEND_HANDLE_NUMERIC(str, hval)) {
-                                       goto num_index_prop;
+               /* here we are sure we are dealing with an object */
+               do {
+                       if (IS_CONST == IS_CONST &&
+                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
+                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
+                               zend_object *zobj = Z_OBJ_P(container);
+
+                               if (EXPECTED(prop_info)) {
+                                       retval = OBJ_PROP(zobj, prop_info->offset);
+                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
+                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                                               break;
+                                       }
+                               } else if (EXPECTED(zobj->properties != NULL)) {
+                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
+                                       if (EXPECTED(retval)) {
+                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                                               break;
+                                       }
                                }
                        }
-str_index_prop:
-                       value = zend_hash_find_ind(ht, str);
-               } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
-                       hval = Z_LVAL_P(offset);
-num_index_prop:
-                       value = zend_hash_index_find(ht, hval);
-               } else {
-                       switch (Z_TYPE_P(offset)) {
-                               case IS_DOUBLE:
-                                       hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                                       goto num_index_prop;
-                               case IS_NULL:
-                                       str = STR_EMPTY_ALLOC();
-                                       goto str_index_prop;
-                               case IS_FALSE:
-                                       hval = 0;
-                                       goto num_index_prop;
-                               case IS_TRUE:
-                                       hval = 1;
-                                       goto num_index_prop;
-                               case IS_RESOURCE:
-                                       hval = Z_RES_HANDLE_P(offset);
-                                       goto num_index_prop;
-                               case IS_REFERENCE:
-                                       offset = Z_REFVAL_P(offset);
-                                       goto isset_again;
-                               default:
-                                       zend_error(E_WARNING, "Illegal offset type in isset or empty");
-                                       value = NULL;
-                                       break;
-                       }
-               }
 
-               if (opline->extended_value & ZEND_ISSET) {
-                       /* > IS_NULL means not IS_UNDEF and not IS_NULL */
-                       result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
-               }
-       } else if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
-                       result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
-               } else {
-                       zend_error(E_NOTICE, "Trying to check element of non-array");
-                       result = 0;
-               }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
-               }
-       } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
-               zval tmp;
+                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
 
-               result = 0;
-               if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
-                       if (IS_CONST == IS_CV || IS_CONST == IS_VAR) {
-                               ZVAL_DEREF(offset);
-                       }
-                       if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
-                                       || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
-                                               && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
-                               ZVAL_DUP(&tmp, offset);
-                               convert_to_long(&tmp);
-                               offset = &tmp;
-                       }
-               }
-               if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
-                       if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
-                               if ((opline->extended_value & ZEND_ISSET) ||
-                                   Z_STRVAL_P(container)[offset->value.lval] != '0') {
-                                       result = 1;
-                               }
+                       if (retval != EX_VAR(opline->result.var)) {
+                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
                        }
-               }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
-               }
-       } else {
-               result = ((opline->extended_value & ZEND_ISSET) == 0);
+               } while (0);
        }
 
-       ZVAL_BOOL(EX_VAR(opline->result.var), result);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
        zval *container;
-       int result;
-       zval *offset;
 
-       SAVE_OPLINE();
-       container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
-       offset = opline->op2.zv;
+       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+               /* Behave like FETCH_OBJ_W */
+               zend_free_op free_op1;
+               zval *property;
 
-       if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
-                       result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
-               } else {
-                       zend_error(E_NOTICE, "Trying to check property of non-object");
-                       result = 0;
+               SAVE_OPLINE();
+               property = opline->op2.zv;
+               container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+
+        if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
+            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+        }
+               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
                }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
+               zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+
+               if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
                }
+
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
        } else {
-               result = ((opline->extended_value & ZEND_ISSET) == 0);
+               return ZEND_FETCH_OBJ_R_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
+}
 
-       ZVAL_BOOL(EX_VAR(opline->result.var), result);
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *container, *property;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
+       property = opline->op2.zv;
+
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+       }
+       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CONST, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
+
+       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+       }
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INSTANCEOF_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_LIST_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *expr;
-       zend_bool result;
+       zval *container;
 
        SAVE_OPLINE();
-       expr = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+       container = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
 
-       if (Z_TYPE_P(expr) == IS_OBJECT) {
-               zend_class_entry *ce;
+       if (EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
 
-               if (IS_CONST == IS_CONST) {
-                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                       } else {
-                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, ZEND_FETCH_CLASS_NO_AUTOLOAD TSRMLS_CC);
-                               if (UNEXPECTED(ce == NULL)) {
-                                       ZVAL_FALSE(EX_VAR(opline->result.var));
+               zval *value = zend_fetch_dimension_address_inner(Z_ARRVAL_P(container), opline->op2.zv, IS_CONST, BP_VAR_R TSRMLS_CC);
 
-                                       CHECK_EXCEPTION();
-                                       ZEND_VM_NEXT_OPCODE();
-                               }
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+               ZVAL_COPY(EX_VAR(opline->result.var), value);
+       } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT) &&
+                  EXPECTED(Z_OBJ_HT_P(container)->read_dimension)) {
+               zval *result = EX_VAR(opline->result.var);
+               zval *retval = Z_OBJ_HT_P(container)->read_dimension(container, opline->op2.zv, BP_VAR_R, result TSRMLS_CC);
+
+               if (retval) {
+                       if (result != retval) {
+                               ZVAL_COPY(result, retval);
                        }
                } else {
-                       ce = Z_CE_P(EX_VAR(opline->op2.var));
+                       ZVAL_NULL(result);
                }
-               result = instanceof_function(Z_OBJCE_P(expr), ce TSRMLS_CC);
        } else {
-               result = 0;
+               ZVAL_NULL(EX_VAR(opline->result.var));
        }
-       ZVAL_BOOL(EX_VAR(opline->result.var), result);
-
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_YIELD_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       /* The generator object is stored in EX(return_value) */
-       zend_generator *generator = (zend_generator *) EX(return_value);
+       zval *object;
+       zval *property_name;
 
-       if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
-               zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
+       SAVE_OPLINE();
+       object = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+       property_name = opline->op2.zv;
+
+       if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
+       zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
 
-       /* Destroy the previously yielded value */
-       zval_ptr_dtor(&generator->value);
 
-       /* Destroy the previously yielded key */
-       zval_ptr_dtor(&generator->key);
+       /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
+       ZEND_VM_INC_OPCODE();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       /* Set the new yielded value */
-       if (IS_CV != IS_UNUSED) {
+static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
+       zval *object_ptr;
 
-               if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
-                       /* Constants and temporary variables aren't yieldable by reference,
-                        * but we still allow them with a notice. */
-                       if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
-                               zval *value;
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
 
-                               zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+       }
+       ZVAL_DEREF(object_ptr);
+       if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
 
-                               value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-                               ZVAL_COPY_VALUE(&generator->value, value);
-                               if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
+               zval *property_name = opline->op2.zv;
 
-                               /* Temporary variables don't need ctor copying */
-                               if (IS_CV != IS_TMP_VAR) {
-                                       zval_opt_copy_ctor(&generator->value);
-                               }
-                       } else {
-                               zval *value_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+               zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
 
-                               if (IS_CV == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
-                                       zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
-                               }
+       } else {
+               zend_free_op free_op_data1;
+               zval  rv;
+               zval *value;
+               zval *dim = opline->op2.zv;
+               zval *variable_ptr;
 
-                               /* If a function call result is yielded and the function did
-                                * not return by reference we throw a notice. */
-                               if (IS_CV == IS_VAR &&
-                                   (value_ptr == &EG(uninitialized_zval) ||
-                                    (opline->extended_value == ZEND_RETURNS_FUNCTION &&
-                                     !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
-                                       zend_error(E_NOTICE, "Only variable references should be yielded by reference");
-                               } else {
-                                       ZVAL_MAKE_REF(value_ptr);
-                               }
-                               ZVAL_COPY(&generator->value, value_ptr);
+               if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
+                   EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
+                       zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
 
-                       }
+                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+                       zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
+                       FREE_OP(free_op_data1);
                } else {
-                       zval *value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-
-                       /* Consts, temporary variables and references need copying */
-                       if (IS_CV == IS_CONST) {
-                               ZVAL_DUP(&generator->value, value);
-                       } else if (IS_CV == IS_TMP_VAR) {
-                               ZVAL_COPY_VALUE(&generator->value, value);
-            } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(value)) {
-                               ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
+                       zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_CONST TSRMLS_CC);
 
+                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+                       ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+                       variable_ptr = Z_INDIRECT(rv);
+                       if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
+                               FREE_OP(free_op_data1);
+                               if (RETURN_VALUE_USED(opline)) {
+                                       ZVAL_NULL(EX_VAR(opline->result.var));
+                               }
                        } else {
-                               ZVAL_COPY_VALUE(&generator->value, value);
-                               if (IS_CV == IS_CV) {
-                                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+                               value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
+                               if ((opline+1)->op1_type == IS_VAR) {
+                                       FREE_OP(free_op_data1);
+                               }
+                               if (RETURN_VALUE_USED(opline)) {
+                                       ZVAL_COPY(EX_VAR(opline->result.var), value);
                                }
                        }
                }
-       } else {
-               /* If no value was specified yield null */
-               ZVAL_NULL(&generator->value);
        }
 
-       /* Set the new yielded key */
-       if (IS_CONST != IS_UNUSED) {
+       /* assign_dim has two opcodes! */
+       CHECK_EXCEPTION();
+       ZEND_VM_INC_OPCODE();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-               zval *key = opline->op2.zv;
+static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-               /* Consts, temporary variables and references need copying */
-               if (IS_CONST == IS_CONST) {
-                       ZVAL_DUP(&generator->key, key);
-               } else if (IS_CONST == IS_TMP_VAR) {
-                       ZVAL_COPY_VALUE(&generator->key, key);
-               } else if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) && Z_ISREF_P(key)) {
-                       ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
+       zval *value;
+       zval *variable_ptr;
 
-               } else {
-                       ZVAL_COPY_VALUE(&generator->key, key);
-                       if (IS_CONST == IS_CV) {
-                               if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
-                       }
-               }
+       SAVE_OPLINE();
+       value = opline->op2.zv;
+       variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
 
-               if (Z_TYPE(generator->key) == IS_LONG
-                   && Z_LVAL(generator->key) > generator->largest_used_integer_key
-               ) {
-                       generator->largest_used_integer_key = Z_LVAL(generator->key);
+       if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
+               if (IS_CONST == IS_TMP_VAR) {
+
+               }
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
                }
        } else {
-               /* If no key was specified we use auto-increment keys */
-               generator->largest_used_integer_key++;
-               ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
-       }
+               value = zend_assign_to_variable(variable_ptr, value, IS_CONST TSRMLS_CC);
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_COPY(EX_VAR(opline->result.var), value);
+               }
 
-       if (RETURN_VALUE_USED(opline)) {
-               /* If the return value of yield is used set the send
-                * target and initialize it to NULL */
-               generator->send_target = EX_VAR(opline->result.var);
-               ZVAL_NULL(generator->send_target);
-       } else {
-               generator->send_target = NULL;
        }
 
-       /* We increment to the next op, so we are at the correct position when the
-        * generator is resumed. */
-       ZEND_VM_INC_OPCODE();
-
-       /* The GOTO VM uses a local opline variable. We need to set the opline
-        * variable in execute_data so we don't resume at an old position. */
-       SAVE_OPLINE();
+       /* zend_assign_to_variable() always takes care of op2, never free it! */
 
-       ZEND_VM_RETURN();
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_POW_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zval *function_name;
 
+       zval *object;
+       zend_function *fbc;
+       zend_class_entry *called_scope;
+       zend_object *obj;
 
        SAVE_OPLINE();
-       pow_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               opline->op2.zv TSRMLS_CC);
 
+       function_name = opline->op2.zv;
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+       if (IS_CONST != IS_CONST &&
+           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
+               if (UNEXPECTED(EG(exception) != NULL)) {
+                       HANDLE_EXCEPTION();
+               }
+               zend_error_noreturn(E_ERROR, "Method name must be a string");
+       }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_POW_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_binary_assign_op_helper_SPEC_CV_CONST(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+       object = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
 
-static int ZEND_FASTCALL  ZEND_BIND_GLOBAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+               uint32_t nesting = 1;
 
-       zval *varname;
-       zval *value;
-       zval *variable_ptr;
-       uint32_t idx;
+               if (UNEXPECTED(EG(exception) != NULL)) {
 
-       SAVE_OPLINE();
-       varname = opline->op2.zv;
+                       HANDLE_EXCEPTION();
+               }
 
-       /* We store "hash slot index" + 1 (NULL is a mark of uninitialized cache slot) */
-       idx = (uint32_t)(uintptr_t)CACHED_PTR(Z_CACHE_SLOT_P(varname)) - 1;
-       if (EXPECTED(idx < EG(symbol_table).ht.nNumUsed)) {
-               Bucket *p = EG(symbol_table).ht.arData + idx;
+               zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s",  Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
 
-               if (EXPECTED(Z_TYPE(p->val) != IS_UNDEF) &&
-               (EXPECTED(p->key == Z_STR_P(varname)) ||
-                (EXPECTED(p->h == Z_STR_P(varname)->h) &&
-                 EXPECTED(p->key != NULL) &&
-                 EXPECTED(p->key->len == Z_STRLEN_P(varname)) &&
-                 EXPECTED(memcmp(p->key->val, Z_STRVAL_P(varname), Z_STRLEN_P(varname)) == 0)))) {
 
-                       value = &EG(symbol_table).ht.arData[idx].val;
-                       goto check_indirect;
+               if (EG(exception) != NULL) {
+                       HANDLE_EXCEPTION();
+               }
+
+               /* No exception raised: Skip over arguments until fcall opcode with correct
+                * nesting level. Return NULL (except when return value unused) */
+               do {
+                       opline++;
+                       if (opline->opcode == ZEND_INIT_FCALL ||
+                               opline->opcode == ZEND_INIT_FCALL_BY_NAME ||
+                               opline->opcode == ZEND_INIT_NS_FCALL_BY_NAME ||
+                               opline->opcode == ZEND_INIT_METHOD_CALL ||
+                               opline->opcode == ZEND_INIT_STATIC_METHOD_CALL ||
+                               opline->opcode == ZEND_INIT_USER_CALL ||
+                               opline->opcode == ZEND_NEW
+                       ) {
+                               nesting++;
+                       } else if (opline->opcode == ZEND_DO_FCALL) {
+                               nesting--;
+                       }
+               } while (nesting);
+
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
+
+               /* We've skipped EXT_FCALL_BEGIND, so also skip the ending opcode */
+               if ((opline + 1)->opcode == ZEND_EXT_FCALL_END) {
+                       opline++;
+               }
+               ZEND_VM_JMP(++opline);
+       }
+
+       obj = Z_OBJ_P(object);
+       called_scope = obj->ce;
+
+       if (IS_CONST != IS_CONST ||
+           EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
+           zend_object *orig_obj = obj;
+
+               if (UNEXPECTED(obj->handlers->get_method == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Object does not support method calls");
+               }
+
+               /* First, locate the function. */
+               fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_CONST == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
+               if (UNEXPECTED(fbc == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
+               }
+               if (IS_CONST == IS_CONST &&
+                   EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
+                   EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
+                   EXPECTED(obj == orig_obj)) {
+                       CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope, fbc);
                }
        }
 
-       value = zend_hash_find(&EG(symbol_table).ht, Z_STR_P(varname));
-       if (UNEXPECTED(value == NULL)) {
-               value = zend_hash_add_new(&EG(symbol_table).ht, Z_STR_P(varname), &EG(uninitialized_zval));
-               idx = ((char*)value - (char*)EG(symbol_table).ht.arData) / sizeof(Bucket);
-               /* Store "hash slot index" + 1 (NULL is a mark of uninitialized cache slot) */
-               CACHE_PTR(Z_CACHE_SLOT_P(varname), (void*)(uintptr_t)(idx + 1));
+       if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_STATIC) != 0)) {
+               obj = NULL;
        } else {
-               idx = ((char*)value - (char*)EG(symbol_table).ht.arData) / sizeof(Bucket);
-               /* Store "hash slot index" + 1 (NULL is a mark of uninitialized cache slot) */
-               CACHE_PTR(Z_CACHE_SLOT_P(varname), (void*)(uintptr_t)(idx + 1));
-check_indirect:
-               /* GLOBAL variable may be an INDIRECT pointer to CV */
-               if (UNEXPECTED(Z_TYPE_P(value) == IS_INDIRECT)) {
-                       value = Z_INDIRECT_P(value);
-                       if (UNEXPECTED(Z_TYPE_P(value) == IS_UNDEF)) {
-                               ZVAL_NULL(value);
-                       }
-               }
+               GC_REFCOUNT(obj)++; /* For $this pointer */
        }
 
-       variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-       zend_assign_to_variable_reference(variable_ptr, value TSRMLS_CC);
+       EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
+               fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
+
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_MOD_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_CASE_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
+
+       zval *result = EX_VAR(opline->result.var);
 
        SAVE_OPLINE();
-       fast_mod_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       fast_equal_function(result,
+                _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+                opline->op2.zv TSRMLS_CC);
 
-       zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_SL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
 
-       SAVE_OPLINE();
-       shift_left_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       zval *expr_ptr, new_expr;
 
-       zval_ptr_dtor_nogc(free_op2);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+       SAVE_OPLINE();
+       if ((IS_CV == IS_VAR || IS_CV == IS_CV) &&
+           (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
+               expr_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+               if (IS_CV == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
+               }
+               ZVAL_MAKE_REF(expr_ptr);
+               Z_ADDREF_P(expr_ptr);
 
-static int ZEND_FASTCALL  ZEND_SR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
+       } else {
+               expr_ptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+               if (IS_CV == IS_TMP_VAR) {
+                       ZVAL_COPY_VALUE(&new_expr, expr_ptr);
+                       expr_ptr = &new_expr;
+               } else if (IS_CV == IS_CONST) {
+                       if (!Z_IMMUTABLE_P(expr_ptr)) {
+                               ZVAL_DUP(&new_expr, expr_ptr);
+                               expr_ptr = &new_expr;
+                       }
+               } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(expr_ptr)) {
+                       expr_ptr = Z_REFVAL_P(expr_ptr);
+                       if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
 
-       SAVE_OPLINE();
-       shift_right_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               } else if (IS_CV == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
+                       Z_ADDREF_P(expr_ptr);
+               }
+       }
 
-       zval_ptr_dtor_nogc(free_op2);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+       if (IS_CONST != IS_UNUSED) {
 
-static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
+               zval *offset = opline->op2.zv;
+               zend_string *str;
+               zend_ulong hval;
 
-       SAVE_OPLINE();
-       concat_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+add_again:
+               switch (Z_TYPE_P(offset)) {
+                       case IS_DOUBLE:
+                               hval = zend_dval_to_lval(Z_DVAL_P(offset));
+                               goto num_index;
+                       case IS_LONG:
+                               hval = Z_LVAL_P(offset);
+num_index:
+                               zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
+                               break;
+                       case IS_STRING:
+                               str = Z_STR_P(offset);
+                               if (IS_CONST != IS_CONST) {
+                                       if (ZEND_HANDLE_NUMERIC(str, hval)) {
+                                               goto num_index;
+                                       }
+                               }
+str_index:
+                               zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
+                               break;
+                       case IS_NULL:
+                               str = STR_EMPTY_ALLOC();
+                               goto str_index;
+                       case IS_FALSE:
+                               hval = 0;
+                               goto num_index;
+                       case IS_TRUE:
+                               hval = 1;
+                               goto num_index;
+                       case IS_REFERENCE:
+                               offset = Z_REFVAL_P(offset);
+                               goto add_again;
+                               break;
+                       default:
+                               zend_error(E_WARNING, "Illegal offset type");
+                               zval_ptr_dtor(expr_ptr);
+                               /* do nothing */
+                               break;
+               }
 
-       zval_ptr_dtor_nogc(free_op2);
+       } else {
+               zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
+       }
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
+       zval *array;
+       uint32_t size;
        USE_OPLINE
-       zend_free_op free_op2;
 
-       SAVE_OPLINE();
-       fast_is_identical_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       array = EX_VAR(opline->result.var);
+       if (IS_CV != IS_UNUSED) {
+               size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
+       } else {
+               size = 0;
+       }
+       ZVAL_NEW_ARR(array);
+       zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
 
-       zval_ptr_dtor_nogc(free_op2);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       if (IS_CV != IS_UNUSED) {
+               /* Explicitly initialize array as not-packed if flag is set */
+               if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
+                       zend_hash_real_init(Z_ARRVAL_P(array), 0);
+               }
+       }
+
+       if (IS_CV == IS_UNUSED) {
+               ZEND_VM_NEXT_OPCODE();
+#if 0 || IS_CV != IS_UNUSED
+       } else {
+               return ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+#endif
+       }
 }
 
-static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
-       zval *result = EX_VAR(opline->result.var);
+       zval tmp, *varname;
+       HashTable *target_symbol_table;
+
 
        SAVE_OPLINE();
-       fast_is_not_identical_function(result,
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       if (IS_CV == IS_CV &&
+           IS_CONST == IS_UNUSED &&
+           (opline->extended_value & ZEND_QUICK_SET)) {
+               zval *var = EX_VAR(opline->op1.var);
 
-       zval_ptr_dtor_nogc(free_op2);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+               if (Z_REFCOUNTED_P(var)) {
+                       zend_refcounted *garbage = Z_COUNTED_P(var);
 
-static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
+                       if (!--GC_REFCOUNT(garbage)) {
+                               ZVAL_UNDEF(var);
+                               _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
+                       } else {
+                               GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
+                               ZVAL_UNDEF(var);
+                       }
+               } else {
+                       ZVAL_UNDEF(var);
+               }
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
+       }
 
-       SAVE_OPLINE();
-       bitwise_or_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       varname = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
 
-       zval_ptr_dtor_nogc(free_op2);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+       ZVAL_UNDEF(&tmp);
+       if (IS_CV != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
+               ZVAL_STR(&tmp, zval_get_string(varname));
+               varname = &tmp;
+       }
 
-static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
+       if (IS_CONST != IS_UNUSED) {
+               zend_class_entry *ce;
 
-       SAVE_OPLINE();
-       bitwise_and_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               if (IS_CONST == IS_CONST) {
+                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+                       } else {
+                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+                               if (UNEXPECTED(EG(exception) != NULL)) {
+                                       if (IS_CV != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+                                               zend_string_release(Z_STR(tmp));
+                                       }
+
+                                       HANDLE_EXCEPTION();
+                               }
+                               if (UNEXPECTED(ce == NULL)) {
+                                       zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
+                               }
+                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+                       }
+               } else {
+                       ce = Z_CE_P(EX_VAR(opline->op2.var));
+               }
+               zend_std_unset_static_property(ce, Z_STR_P(varname), ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+       } else {
+               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+               zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
+       }
+
+       if (IS_CV != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+               zend_string_release(Z_STR(tmp));
+       }
 
-       zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
+
+       zval *container;
+       zval *offset;
+       zend_ulong hval;
 
        SAVE_OPLINE();
-       bitwise_xor_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
+       }
+       if (IS_CV != IS_UNUSED) {
+               ZVAL_DEREF(container);
+       }
+       SEPARATE_ZVAL_NOREF(container);
+       offset = opline->op2.zv;
 
-       zval_ptr_dtor_nogc(free_op2);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+       if (IS_CV != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
+               HashTable *ht = Z_ARRVAL_P(container);
+offset_again:
+               switch (Z_TYPE_P(offset)) {
+                       case IS_DOUBLE:
+                               hval = zend_dval_to_lval(Z_DVAL_P(offset));
+                               zend_hash_index_del(ht, hval);
+                               break;
+                       case IS_LONG:
+                               hval = Z_LVAL_P(offset);
+num_index_dim:
+                               zend_hash_index_del(ht, hval);
+                               break;
+                       case IS_STRING:
+                               if (IS_CONST != IS_CONST) {
+                                       if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
+                                               goto num_index_dim;
+                                       }
+                               }
+                               if (ht == &EG(symbol_table).ht) {
+                                       zend_delete_global_variable(Z_STR_P(offset) TSRMLS_CC);
+                               } else {
+                                       zend_hash_del(ht, Z_STR_P(offset));
+                               }
+                               break;
+                       case IS_NULL:
+                               zend_hash_del(ht, STR_EMPTY_ALLOC());
+                               break;
+                       case IS_FALSE:
+                               hval = 0;
+                               goto num_index_dim;
+                       case IS_TRUE:
+                               hval = 1;
+                               goto num_index_dim;
+                       case IS_RESOURCE:
+                               hval = Z_RES_HANDLE_P(offset);
+                               goto num_index_dim;
+                       case IS_REFERENCE:
+                               offset = Z_REFVAL_P(offset);
+                               goto offset_again;
+                               break;
+                       default:
+                               zend_error(E_WARNING, "Illegal offset type in unset");
+                               break;
+               }
 
-static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
+       } else if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+               if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot use object as array");
+               }
+//???          if (IS_CONST == IS_CONST) {
+//???                  zval_copy_ctor(offset);
+//???          }
+               Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
 
-       SAVE_OPLINE();
-       boolean_xor_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
+               ZEND_VM_CONTINUE(); /* bailed out before */
+       } else {
+
+       }
 
-       zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2, free_op_data1;
-       zval *object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
-       zval *property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-       zval *value;
-       zval *zptr;
 
-       if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+       zval *container;
+       zval *offset;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
        }
+       offset = opline->op2.zv;
 
        if (IS_CV != IS_UNUSED) {
-               object = make_real_object(object TSRMLS_CC);
+               ZVAL_DEREF(container);
        }
-
-       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-
-       if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
-               zend_error(E_WARNING, "Attempt to assign property of non-object");
-               zval_ptr_dtor_nogc(free_op2);
-               FREE_OP(free_op_data1);
-
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
-               }
-       } else {
-               /* here we are sure we are dealing with an object */
-               if (opline->extended_value == ZEND_ASSIGN_OBJ
-                       && EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-                       && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
-
-                       ZVAL_DEREF(zptr);
-                       SEPARATE_ZVAL_NOREF(zptr);
-
-                       binary_op(zptr, zptr, value TSRMLS_CC);
-                       if (RETURN_VALUE_USED(opline)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), zptr);
-                       }
+       if (IS_CV == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
+               if (Z_OBJ_HT_P(container)->unset_property) {
+                       Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
                } else {
-                       zval *z = NULL;
-                       zval rv;
-
-                       if (opline->extended_value == ZEND_ASSIGN_OBJ) {
-                               if (Z_OBJ_HT_P(object)->read_property) {
-                                       z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
-                               }
-                       } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
-                               if (Z_OBJ_HT_P(object)->read_dimension) {
-                                       z = Z_OBJ_HT_P(object)->read_dimension(object, property, BP_VAR_R, &rv TSRMLS_CC);
-                               }
-                       }
-                       if (z) {
-                               if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
-                                       zval rv;
-                                       zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
-
-                                       if (Z_REFCOUNT_P(z) == 0) {
-                                               zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
-                                       }
-                                       ZVAL_COPY_VALUE(z, value);
-                               }
-//???                          if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
-                               SEPARATE_ZVAL_IF_NOT_REF(z);
-                               binary_op(z, z, value TSRMLS_CC);
-                               if (opline->extended_value == ZEND_ASSIGN_OBJ) {
-                                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
-                               } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
-                                       Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
-                               }
-                               if (RETURN_VALUE_USED(opline)) {
-                                       ZVAL_COPY(EX_VAR(opline->result.var), z);
-                               }
-                               zval_ptr_dtor(z);
-                       } else {
-                               zend_error(E_WARNING, "Attempt to assign property of non-object");
-                               if (RETURN_VALUE_USED(opline)) {
-                                       ZVAL_NULL(EX_VAR(opline->result.var));
-                               }
-                       }
+                       zend_error(E_NOTICE, "Trying to unset property of non-object");
                }
-
-               zval_ptr_dtor_nogc(free_op2);
-               FREE_OP(free_op_data1);
        }
 
-       /* assign_obj has two opcodes! */
+
        CHECK_EXCEPTION();
-       ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_CV_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2, free_op_data1;
-       zval *var_ptr, rv;
-       zval *value, *container;
+       zval *value;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-       }
-       if (IS_CV != IS_UNUSED) {
-               ZVAL_DEREF(container);
-       }
-       if (IS_CV == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (IS_CV == IS_VAR && !0) {
-                       Z_ADDREF_P(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
+       if (IS_CV == IS_CV &&
+           IS_CONST == IS_UNUSED &&
+           (opline->extended_value & ZEND_QUICK_SET)) {
+               value = EX_VAR(opline->op1.var);
+               if (opline->extended_value & ZEND_ISSET) {
+                       ZVAL_BOOL(EX_VAR(opline->result.var),
+                               Z_TYPE_P(value) > IS_NULL &&
+                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+                       ZVAL_BOOL(EX_VAR(opline->result.var),
+                               !i_zend_is_true(value TSRMLS_CC));
+                       CHECK_EXCEPTION();
                }
-               return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               ZEND_VM_NEXT_OPCODE();
        } else {
-               zval *dim = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
 
-               zend_fetch_dimension_address_RW(&rv, container, dim, IS_TMP_VAR TSRMLS_CC);
-               value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-               ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
-               var_ptr = Z_INDIRECT(rv);
-       }
+               zval tmp, *varname = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
 
-       if (UNEXPECTED(var_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
-       }
+               ZVAL_UNDEF(&tmp);
+               if (IS_CV != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
+                       ZVAL_STR(&tmp, zval_get_string(varname));
+                       varname = &tmp;
+               }
 
-       if (UNEXPECTED(var_ptr == &EG(error_zval))) {
-               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
+               if (IS_CONST != IS_UNUSED) {
+                       zend_class_entry *ce;
+
+                       if (IS_CONST == IS_CONST) {
+                               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                                       ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+                               } else {
+                                       ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+                                       if (UNEXPECTED(ce == NULL)) {
+                                               CHECK_EXCEPTION();
+                                               ZEND_VM_NEXT_OPCODE();
+                                       }
+                                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+                               }
+                       } else {
+                               ce = Z_CE_P(EX_VAR(opline->op2.var));
+                       }
+                       value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+               } else {
+                       HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+                       value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
                }
-       } else {
-               ZVAL_DEREF(var_ptr);
-               SEPARATE_ZVAL_NOREF(var_ptr);
 
-               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
-
-               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+               if (IS_CV != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+                       zend_string_release(Z_STR(tmp));
                }
-       }
 
-       zval_ptr_dtor_nogc(free_op2);
-       FREE_OP(free_op_data1);
+               if (opline->extended_value & ZEND_ISSET) {
+                       ZVAL_BOOL(EX_VAR(opline->result.var),
+                               value && Z_TYPE_P(value) > IS_NULL &&
+                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+                       ZVAL_BOOL(EX_VAR(opline->result.var),
+                               !value || !i_zend_is_true(value TSRMLS_CC));
+               }
 
-       CHECK_EXCEPTION();
-       ZEND_VM_INC_OPCODE();
-       ZEND_VM_NEXT_OPCODE();
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
+       }
 }
 
-static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
-       zval *var_ptr;
-       zval *value;
+
+       zval *container;
+       int result;
+       zend_ulong hval;
+       zval *offset;
 
        SAVE_OPLINE();
-       value = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-       var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+       container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
+       offset = opline->op2.zv;
 
-       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
-       }
+       if (IS_CV != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
+               HashTable *ht = Z_ARRVAL_P(container);
+               zval *value;
+               zend_string *str;
 
-       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
-               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
+isset_again:
+               if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
+                       str = Z_STR_P(offset);
+                       if (IS_CONST != IS_CONST) {
+                               if (ZEND_HANDLE_NUMERIC(str, hval)) {
+                                       goto num_index_prop;
+                               }
+                       }
+str_index_prop:
+                       value = zend_hash_find_ind(ht, str);
+               } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
+                       hval = Z_LVAL_P(offset);
+num_index_prop:
+                       value = zend_hash_index_find(ht, hval);
+               } else {
+                       switch (Z_TYPE_P(offset)) {
+                               case IS_DOUBLE:
+                                       hval = zend_dval_to_lval(Z_DVAL_P(offset));
+                                       goto num_index_prop;
+                               case IS_NULL:
+                                       str = STR_EMPTY_ALLOC();
+                                       goto str_index_prop;
+                               case IS_FALSE:
+                                       hval = 0;
+                                       goto num_index_prop;
+                               case IS_TRUE:
+                                       hval = 1;
+                                       goto num_index_prop;
+                               case IS_RESOURCE:
+                                       hval = Z_RES_HANDLE_P(offset);
+                                       goto num_index_prop;
+                               case IS_REFERENCE:
+                                       offset = Z_REFVAL_P(offset);
+                                       goto isset_again;
+                               default:
+                                       zend_error(E_WARNING, "Illegal offset type in isset or empty");
+                                       value = NULL;
+                                       break;
+                       }
                }
-       } else {
-               ZVAL_DEREF(var_ptr);
-               SEPARATE_ZVAL_NOREF(var_ptr);
 
-               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
+               if (opline->extended_value & ZEND_ISSET) {
+                       /* > IS_NULL means not IS_UNDEF and not IS_NULL */
+                       result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
+                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
+               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+                       result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
+               }
+       } else if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+               if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
+                       result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
+               } else {
+                       zend_error(E_NOTICE, "Trying to check element of non-array");
+                       result = 0;
+               }
+               if ((opline->extended_value & ZEND_ISSET) == 0) {
+                       result = !result;
+               }
+       } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
+               zval tmp;
 
-               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+               result = 0;
+               if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
+                       if (IS_CONST & (IS_CV|IS_VAR)) {
+                               ZVAL_DEREF(offset);
+                       }
+                       if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
+                                       || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
+                                               && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
+                               ZVAL_DUP(&tmp, offset);
+                               convert_to_long(&tmp);
+                               offset = &tmp;
+                       }
+               }
+               if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
+                       if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
+                               if ((opline->extended_value & ZEND_ISSET) ||
+                                   Z_STRVAL_P(container)[offset->value.lval] != '0') {
+                                       result = 1;
+                               }
+                       }
+               }
+               if ((opline->extended_value & ZEND_ISSET) == 0) {
+                       result = !result;
                }
+       } else {
+               result = ((opline->extended_value & ZEND_ISSET) == 0);
        }
 
-       zval_ptr_dtor_nogc(free_op2);
+       ZVAL_BOOL(EX_VAR(opline->result.var), result);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_ADD_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
+       zval *container;
+       int result;
+       zval *offset;
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SUB_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       SAVE_OPLINE();
+       container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
+       offset = opline->op2.zv;
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+               if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
+                       result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_CONST == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+               } else {
+                       zend_error(E_NOTICE, "Trying to check property of non-object");
+                       result = 0;
+               }
+               if ((opline->extended_value & ZEND_ISSET) == 0) {
+                       result = !result;
+               }
+       } else {
+               result = ((opline->extended_value & ZEND_ISSET) == 0);
        }
-}
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_MUL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       ZVAL_BOOL(EX_VAR(opline->result.var), result);
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_DIV_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INSTANCEOF_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
+       zval *expr;
+       zend_bool result;
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_MOD_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       SAVE_OPLINE();
+       expr = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
+       if (Z_TYPE_P(expr) == IS_OBJECT) {
+               zend_class_entry *ce;
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+               if (IS_CONST == IS_CONST) {
+                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+                       } else {
+                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, ZEND_FETCH_CLASS_NO_AUTOLOAD TSRMLS_CC);
+                               if (UNEXPECTED(ce == NULL)) {
+                                       ZVAL_FALSE(EX_VAR(opline->result.var));
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+                                       CHECK_EXCEPTION();
+                                       ZEND_VM_NEXT_OPCODE();
+                               }
+                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+                       }
+               } else {
+                       ce = Z_CE_P(EX_VAR(opline->op2.var));
+               }
+               result = instanceof_function(Z_OBJCE_P(expr), ce TSRMLS_CC);
+       } else {
+               result = 0;
        }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_SR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       ZVAL_BOOL(EX_VAR(opline->result.var), result);
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_CONCAT_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_YIELD_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_OR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       /* The generator object is stored in EX(return_value) */
+       zend_generator *generator = (zend_generator *) EX(return_value);
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
+               zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
        }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_AND_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
+       /* Destroy the previously yielded value */
+       zval_ptr_dtor(&generator->value);
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       /* Destroy the previously yielded key */
+       zval_ptr_dtor(&generator->key);
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
+       /* Set the new yielded value */
+       if (IS_CV != IS_UNUSED) {
 
-static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_TMP(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
-       zval *object;
-       zval *property;
-       zval *retval;
-       zval *zptr;
 
-       SAVE_OPLINE();
-       object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
-       property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-       retval = EX_VAR(opline->result.var);
+               if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
+                       /* Constants and temporary variables aren't yieldable by reference,
+                        * but we still allow them with a notice. */
+                       if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
+                               zval *value;
 
-       if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
-       }
+                               zend_error(E_NOTICE, "Only variable references should be yielded by reference");
 
-       if (IS_CV != IS_UNUSED) {
-               object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
-       }
+                               value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+                               ZVAL_COPY_VALUE(&generator->value, value);
+                               if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
 
-       if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
-               zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-               zval_ptr_dtor_nogc(free_op2);
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(retval);
-               }
+                               /* Temporary variables don't need ctor copying */
+                               if (IS_CV != IS_TMP_VAR) {
+                                       zval_opt_copy_ctor(&generator->value);
+                               }
+                       } else {
+                               zval *value_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
 
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
+                               if (IS_CV == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+                                       zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
+                               }
 
-       /* here we are sure we are dealing with an object */
+                               /* If a function call result is yielded and the function did
+                                * not return by reference we throw a notice. */
+                               if (IS_CV == IS_VAR &&
+                                   (value_ptr == &EG(uninitialized_zval) ||
+                                    (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+                                     !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+                                       zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+                               } else {
+                                       ZVAL_MAKE_REF(value_ptr);
+                               }
+                               ZVAL_COPY(&generator->value, value_ptr);
 
-       if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+                       }
+               } else {
+                       zval *value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
 
-               ZVAL_DEREF(zptr);
-               SEPARATE_ZVAL_NOREF(zptr);
+                       /* Consts, temporary variables and references need copying */
+                       if (IS_CV == IS_CONST) {
+                               ZVAL_DUP(&generator->value, value);
+                       } else if (IS_CV == IS_TMP_VAR) {
+                               ZVAL_COPY_VALUE(&generator->value, value);
+            } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(value)) {
+                               ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
 
-               incdec_op(zptr);
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_COPY(retval, zptr);
+                       } else {
+                               ZVAL_COPY_VALUE(&generator->value, value);
+                               if (IS_CV == IS_CV) {
+                                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+                               }
+                       }
                }
        } else {
-               zval rv;
+               /* If no value was specified yield null */
+               ZVAL_NULL(&generator->value);
+       }
 
-               if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
-                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+       /* Set the new yielded key */
+       if (IS_CONST != IS_UNUSED) {
 
-                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
-                               zval rv;
-                               zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+               zval *key = opline->op2.zv;
+
+               /* Consts, temporary variables and references need copying */
+               if (IS_CONST == IS_CONST) {
+                       ZVAL_DUP(&generator->key, key);
+               } else if (IS_CONST == IS_TMP_VAR) {
+                       ZVAL_COPY_VALUE(&generator->key, key);
+               } else if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) && Z_ISREF_P(key)) {
+                       ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
 
-                               if (Z_REFCOUNT_P(z) == 0) {
-                                       zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
-                               }
-                               ZVAL_COPY_VALUE(z, value);
-                       }
-                       if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
-                       SEPARATE_ZVAL_IF_NOT_REF(z);
-                       incdec_op(z);
-                       ZVAL_COPY_VALUE(retval, z);
-                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
-                       SELECTIVE_PZVAL_LOCK(retval, opline);
-                       zval_ptr_dtor(z);
                } else {
-                       zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-                       if (RETURN_VALUE_USED(opline)) {
-                               ZVAL_NULL(retval);
+                       ZVAL_COPY_VALUE(&generator->key, key);
+                       if (IS_CONST == IS_CV) {
+                               if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
                        }
                }
+
+               if (Z_TYPE(generator->key) == IS_LONG
+                   && Z_LVAL(generator->key) > generator->largest_used_integer_key
+               ) {
+                       generator->largest_used_integer_key = Z_LVAL(generator->key);
+               }
+       } else {
+               /* If no key was specified we use auto-increment keys */
+               generator->largest_used_integer_key++;
+               ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
        }
 
-       zval_ptr_dtor_nogc(free_op2);
+       if (RETURN_VALUE_USED(opline)) {
+               /* If the return value of yield is used set the send
+                * target and initialize it to NULL */
+               generator->send_target = EX_VAR(opline->result.var);
+               ZVAL_NULL(generator->send_target);
+       } else {
+               generator->send_target = NULL;
+       }
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+       /* We increment to the next op, so we are at the correct position when the
+        * generator is resumed. */
+       ZEND_VM_INC_OPCODE();
 
-static int ZEND_FASTCALL  ZEND_PRE_INC_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_pre_incdec_property_helper_SPEC_CV_TMP(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+       /* The GOTO VM uses a local opline variable. We need to set the opline
+        * variable in execute_data so we don't resume at an old position. */
+       SAVE_OPLINE();
 
-static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_pre_incdec_property_helper_SPEC_CV_TMP(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       ZEND_VM_RETURN();
 }
 
-static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_TMP(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_POW_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
-       zval *object;
-       zval *property;
-       zval *retval;
-       zval *zptr;
+
 
        SAVE_OPLINE();
-       object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
-       property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-       retval = EX_VAR(opline->result.var);
+       pow_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               opline->op2.zv TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
-       }
 
-       if (IS_CV != IS_UNUSED) {
-               object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
-       }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
-               zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-               zval_ptr_dtor_nogc(free_op2);
-               ZVAL_NULL(retval);
+static int ZEND_FASTCALL  ZEND_ASSIGN_POW_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_binary_assign_op_helper_SPEC_CV_CONST(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
 
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
+static int ZEND_FASTCALL  ZEND_BIND_GLOBAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       /* here we are sure we are dealing with an object */
+       zval *varname;
+       zval *value;
+       zval *variable_ptr;
+       uint32_t idx;
 
-       if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+       SAVE_OPLINE();
+       varname = opline->op2.zv;
 
-               ZVAL_DEREF(zptr);
-               ZVAL_COPY_VALUE(retval, zptr);
-               zval_opt_copy_ctor(zptr);
+       /* We store "hash slot index" + 1 (NULL is a mark of uninitialized cache slot) */
+       idx = (uint32_t)(uintptr_t)CACHED_PTR(Z_CACHE_SLOT_P(varname)) - 1;
+       if (EXPECTED(idx < EG(symbol_table).ht.nNumUsed)) {
+               Bucket *p = EG(symbol_table).ht.arData + idx;
 
-               incdec_op(zptr);
-       } else {
-               if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
-                       zval rv;
-                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
-                       zval z_copy;
+               if (EXPECTED(Z_TYPE(p->val) != IS_UNDEF) &&
+               (EXPECTED(p->key == Z_STR_P(varname)) ||
+                (EXPECTED(p->h == Z_STR_P(varname)->h) &&
+                 EXPECTED(p->key != NULL) &&
+                 EXPECTED(p->key->len == Z_STRLEN_P(varname)) &&
+                 EXPECTED(memcmp(p->key->val, Z_STRVAL_P(varname), Z_STRLEN_P(varname)) == 0)))) {
 
-                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
-                               zval rv;
-                               zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+                       value = &EG(symbol_table).ht.arData[idx].val;
+                       goto check_indirect;
+               }
+       }
 
-                               if (Z_REFCOUNT_P(z) == 0) {
-                                       zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
-                               }
-                               ZVAL_COPY_VALUE(z, value);
+       value = zend_hash_find(&EG(symbol_table).ht, Z_STR_P(varname));
+       if (UNEXPECTED(value == NULL)) {
+               value = zend_hash_add_new(&EG(symbol_table).ht, Z_STR_P(varname), &EG(uninitialized_zval));
+               idx = ((char*)value - (char*)EG(symbol_table).ht.arData) / sizeof(Bucket);
+               /* Store "hash slot index" + 1 (NULL is a mark of uninitialized cache slot) */
+               CACHE_PTR(Z_CACHE_SLOT_P(varname), (void*)(uintptr_t)(idx + 1));
+       } else {
+               idx = ((char*)value - (char*)EG(symbol_table).ht.arData) / sizeof(Bucket);
+               /* Store "hash slot index" + 1 (NULL is a mark of uninitialized cache slot) */
+               CACHE_PTR(Z_CACHE_SLOT_P(varname), (void*)(uintptr_t)(idx + 1));
+check_indirect:
+               /* GLOBAL variable may be an INDIRECT pointer to CV */
+               if (UNEXPECTED(Z_TYPE_P(value) == IS_INDIRECT)) {
+                       value = Z_INDIRECT_P(value);
+                       if (UNEXPECTED(Z_TYPE_P(value) == IS_UNDEF)) {
+                               ZVAL_NULL(value);
                        }
-                       ZVAL_DUP(retval, z);
-                       ZVAL_DUP(&z_copy, z);
-                       incdec_op(&z_copy);
-                       if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
-                       Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
-                       zval_ptr_dtor(&z_copy);
-                       zval_ptr_dtor(z);
-               } else {
-                       zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-                       ZVAL_NULL(retval);
                }
        }
 
-       zval_ptr_dtor_nogc(free_op2);
+       variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+       zend_assign_to_variable_reference(variable_ptr, value TSRMLS_CC);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_POST_INC_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_post_incdec_property_helper_SPEC_CV_TMP(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_post_incdec_property_helper_SPEC_CV_TMP(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_MOD_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op2;
-       zval *container;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-       zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
+       fast_mod_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
 
+       zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
-       zval *container;
+       zend_free_op free_op2;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+       shift_left_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-       }
-       ZVAL_DEREF(container);
-       zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op2);
-       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-       }
-
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
-       zval *container;
+       zend_free_op free_op2;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+       shift_right_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-       }
-       ZVAL_DEREF(container);
-       zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op2);
-       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-       }
-
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op2;
-       zval *container;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
-       zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
+       concat_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
 
+       zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *container;
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op2;
 
        SAVE_OPLINE();
+       fast_is_identical_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
 
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-        if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
-            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
-        }
-               container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-               }
-               ZVAL_DEREF(container);
-               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
-               if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-               }
-               zval_ptr_dtor_nogc(free_op2);
-
-       } else {
-               if (IS_TMP_VAR == IS_UNUSED) {
-                       zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
-               }
-               container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op2);
-
-       }
+       zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_UNSET_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
-       zval *container;
+       zend_free_op free_op2;
+       zval *result = EX_VAR(opline->result.var);
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
+       fast_is_not_identical_function(result,
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-       }
-       ZVAL_DEREF(container);
-       zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op2);
-       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-       }
-
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
-       zval *container;
        zend_free_op free_op2;
-       zval *offset;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-       offset  = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-
-       if ((IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
-           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
-               zend_error(E_NOTICE, "Trying to get property of non-object");
-               ZVAL_NULL(EX_VAR(opline->result.var));
-       } else {
-               zval *retval;
-
-               /* here we are sure we are dealing with an object */
-               do {
-                       if (IS_TMP_VAR == IS_CONST &&
-                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
-                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
-                               zend_object *zobj = Z_OBJ_P(container);
-
-                               if (EXPECTED(prop_info)) {
-                                       retval = OBJ_PROP(zobj, prop_info->offset);
-                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               } else if (EXPECTED(zobj->properties != NULL)) {
-                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
-                                       if (EXPECTED(retval)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               }
-                       }
-
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
-
-                       if (retval != EX_VAR(opline->result.var)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                       }
-               } while (0);
-       }
+       bitwise_or_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
 
        zval_ptr_dtor_nogc(free_op2);
-
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
-       zval *property;
-       zval *container;
+       zend_free_op free_op2;
 
        SAVE_OPLINE();
-       property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-
-       container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
-       }
+       bitwise_and_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
 
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op2);
-       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-       }
-
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
-       zval *property;
-       zval *container;
+       zend_free_op free_op2;
 
        SAVE_OPLINE();
-       property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-       container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+       bitwise_xor_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
-       }
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op2);
-       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-       }
-
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
-       zval *container;
        zend_free_op free_op2;
-       zval *offset;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
-       offset  = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-
-       if ((IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
-           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
-               ZVAL_NULL(EX_VAR(opline->result.var));
-       } else {
-               zval *retval;
-
-               /* here we are sure we are dealing with an object */
-               do {
-                       if (IS_TMP_VAR == IS_CONST &&
-                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
-                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
-                               zend_object *zobj = Z_OBJ_P(container);
-
-                               if (EXPECTED(prop_info)) {
-                                       retval = OBJ_PROP(zobj, prop_info->offset);
-                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               } else if (EXPECTED(zobj->properties != NULL)) {
-                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
-                                       if (EXPECTED(retval)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               }
-                       }
-
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
-
-                       if (retval != EX_VAR(opline->result.var)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                       }
-               } while (0);
-       }
+       boolean_xor_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
 
        zval_ptr_dtor_nogc(free_op2);
-
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *container;
+       zend_free_op free_op2, free_op_data1;
+       zval *object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+       zval *property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       zval *value;
+       zval *zptr;
 
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-               /* Behave like FETCH_OBJ_W */
-               zend_free_op free_op1, free_op2;
-               zval *property;
+       if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+       }
 
-               SAVE_OPLINE();
-               property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-               container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+       if (IS_CV != IS_UNUSED) {
+               object = make_real_object(object TSRMLS_CC);
+       }
 
-        if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
-            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
-        }
-               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
-               }
-               zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+
+       if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+               zend_error(E_WARNING, "Attempt to assign property of non-object");
                zval_ptr_dtor_nogc(free_op2);
-               if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-               }
+               FREE_OP(free_op_data1);
 
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
        } else {
-               return ZEND_FETCH_OBJ_R_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1, free_op2;
-       zval *container, *property;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
-       property = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+               /* here we are sure we are dealing with an object */
+               if (opline->extended_value == ZEND_ASSIGN_OBJ
+                       && EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+                       && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
 
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
-       }
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_TMP_VAR, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
-       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-       }
+                       ZVAL_DEREF(zptr);
+                       SEPARATE_ZVAL_NOREF(zptr);
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+                       binary_op(zptr, zptr, value TSRMLS_CC);
+                       if (RETURN_VALUE_USED(opline)) {
+                               ZVAL_COPY(EX_VAR(opline->result.var), zptr);
+                       }
+               } else {
+                       zval *z = NULL;
+                       zval rv;
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
-       zval *object;
-       zval *property_name;
+                       if (opline->extended_value == ZEND_ASSIGN_OBJ) {
+                               if (Z_OBJ_HT_P(object)->read_property) {
+                                       z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+                               }
+                       } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
+                               if (Z_OBJ_HT_P(object)->read_dimension) {
+                                       z = Z_OBJ_HT_P(object)->read_dimension(object, property, BP_VAR_R, &rv TSRMLS_CC);
+                               }
+                       }
+                       if (z) {
+                               if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                                       zval rv;
+                                       zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
 
-       SAVE_OPLINE();
-       object = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-       property_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+                                       if (Z_REFCOUNT_P(z) == 0) {
+                                               zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
+                                       }
+                                       ZVAL_COPY_VALUE(z, value);
+                               }
+//???                          if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
+                               SEPARATE_ZVAL_IF_NOT_REF(z);
+                               binary_op(z, z, value TSRMLS_CC);
+                               if (opline->extended_value == ZEND_ASSIGN_OBJ) {
+                                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+                               } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
+                                       Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
+                               }
+                               if (RETURN_VALUE_USED(opline)) {
+                                       ZVAL_COPY(EX_VAR(opline->result.var), z);
+                               }
+                               zval_ptr_dtor(z);
+                       } else {
+                               zend_error(E_WARNING, "Attempt to assign property of non-object");
+                               if (RETURN_VALUE_USED(opline)) {
+                                       ZVAL_NULL(EX_VAR(opline->result.var));
+                               }
+                       }
+               }
 
-       if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+               zval_ptr_dtor_nogc(free_op2);
+               FREE_OP(free_op_data1);
        }
-       zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
 
        /* assign_obj has two opcodes! */
        CHECK_EXCEPTION();
@@ -37343,599 +31369,465 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLE
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_CV_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
-       zval *object_ptr;
+       zend_free_op free_op2, free_op_data1;
+       zval *var_ptr, rv;
+       zval *value, *container;
 
        SAVE_OPLINE();
-       object_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-
-       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
+       container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       ZVAL_DEREF(object_ptr);
-       if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
-               zend_free_op free_op2;
-               zval *property_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-
-               zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op2);
+       if (IS_CV != IS_UNUSED) {
+               ZVAL_DEREF(container);
+       }
+       if (IS_CV == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+               if (IS_CV == IS_VAR && !0) {
+                       Z_ADDREF_P(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
+               }
+               return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else {
-               zend_free_op free_op2, free_op_data1;
-               zval  rv;
-               zval *value;
                zval *dim = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-               zval *variable_ptr;
 
-               if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
-                   EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
-                       zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
-                       zval_ptr_dtor_nogc(free_op2);
-                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-                       zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
-                       FREE_OP(free_op_data1);
-               } else {
-                       zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_TMP_VAR TSRMLS_CC);
-                       zval_ptr_dtor_nogc(free_op2);
-                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-                       ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
-                       variable_ptr = Z_INDIRECT(rv);
-                       if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
-                               FREE_OP(free_op_data1);
-                               if (RETURN_VALUE_USED(opline)) {
-                                       ZVAL_NULL(EX_VAR(opline->result.var));
-                               }
-                       } else {
-                               value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
-                               if ((opline+1)->op1_type == IS_VAR) {
-                                       FREE_OP(free_op_data1);
-                               }
-                               if (RETURN_VALUE_USED(opline)) {
-                                       ZVAL_COPY(EX_VAR(opline->result.var), value);
-                               }
-                       }
+               zend_fetch_dimension_address_RW(&rv, container, dim, IS_TMP_VAR TSRMLS_CC);
+               value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+               ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+               var_ptr = Z_INDIRECT(rv);
+       }
+
+       if (UNEXPECTED(var_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
+       }
+
+       if (UNEXPECTED(var_ptr == &EG(error_zval))) {
+               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
+       } else {
+               ZVAL_DEREF(var_ptr);
+               SEPARATE_ZVAL_NOREF(var_ptr);
+
+               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
+
+               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
                }
        }
 
-       /* assign_dim has two opcodes! */
+       zval_ptr_dtor_nogc(free_op2);
+       FREE_OP(free_op_data1);
+
        CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op2;
+       zval *var_ptr;
        zval *value;
-       zval *variable_ptr;
 
        SAVE_OPLINE();
        value = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-       variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+       var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
-               if (IS_TMP_VAR == IS_TMP_VAR) {
-                       zval_ptr_dtor_nogc(free_op2);
-               }
-               if (RETURN_VALUE_USED(opline)) {
+       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
+       }
+
+       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
                        ZVAL_NULL(EX_VAR(opline->result.var));
                }
        } else {
-               value = zend_assign_to_variable(variable_ptr, value, IS_TMP_VAR TSRMLS_CC);
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_COPY(EX_VAR(opline->result.var), value);
-               }
+               ZVAL_DEREF(var_ptr);
+               SEPARATE_ZVAL_NOREF(var_ptr);
+
+               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
 
+               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+               }
        }
 
-       /* zend_assign_to_variable() always takes care of op2, never free it! */
+       zval_ptr_dtor_nogc(free_op2);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_ADD_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *function_name;
-       zend_free_op free_op2;
-       zval *object;
-       zend_function *fbc;
-       zend_class_entry *called_scope;
-       zend_object *obj;
 
-       SAVE_OPLINE();
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
 
-       function_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+static int ZEND_FASTCALL  ZEND_ASSIGN_SUB_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       if (IS_TMP_VAR != IS_CONST &&
-           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       HANDLE_EXCEPTION();
-               }
-               zend_error_noreturn(E_ERROR, "Method name must be a string");
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
+}
 
-       object = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+static int ZEND_FASTCALL  ZEND_ASSIGN_MUL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
-               uint32_t nesting = 1;
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
 
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       zval_ptr_dtor_nogc(free_op2);
-                       HANDLE_EXCEPTION();
-               }
+static int ZEND_FASTCALL  ZEND_ASSIGN_DIV_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-               zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s",  Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
-               zval_ptr_dtor_nogc(free_op2);
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
 
-               if (EG(exception) != NULL) {
-                       HANDLE_EXCEPTION();
-               }
+static int ZEND_FASTCALL  ZEND_ASSIGN_MOD_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-               /* No exception raised: Skip over arguments until fcall opcode with correct
-                * nesting level. Return NULL (except when return value unused) */
-               do {
-                       opline++;
-                       if (opline->opcode == ZEND_INIT_FCALL ||
-                               opline->opcode == ZEND_INIT_FCALL_BY_NAME ||
-                               opline->opcode == ZEND_INIT_NS_FCALL_BY_NAME ||
-                               opline->opcode == ZEND_INIT_METHOD_CALL ||
-                               opline->opcode == ZEND_INIT_STATIC_METHOD_CALL ||
-                               opline->opcode == ZEND_INIT_USER_CALL ||
-                               opline->opcode == ZEND_NEW
-                       ) {
-                               nesting++;
-                       } else if (opline->opcode == ZEND_DO_FCALL) {
-                               nesting--;
-                       }
-               } while (nesting);
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
 
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
-               }
+static int ZEND_FASTCALL  ZEND_ASSIGN_SL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-               /* We've skipped EXT_FCALL_BEGIND, so also skip the ending opcode */
-               if ((opline + 1)->opcode == ZEND_EXT_FCALL_END) {
-                       opline++;
-               }
-               ZEND_VM_JMP(++opline);
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
+}
 
-       obj = Z_OBJ_P(object);
-       called_scope = obj->ce;
+static int ZEND_FASTCALL  ZEND_ASSIGN_SR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       if (IS_TMP_VAR != IS_CONST ||
-           EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
-           zend_object *orig_obj = obj;
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
 
-               if (UNEXPECTED(obj->handlers->get_method == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Object does not support method calls");
-               }
+static int ZEND_FASTCALL  ZEND_ASSIGN_CONCAT_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-               /* First, locate the function. */
-               fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_TMP_VAR == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
-               if (UNEXPECTED(fbc == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
-               }
-               if (IS_TMP_VAR == IS_CONST &&
-                   EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
-                   EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
-                   EXPECTED(obj == orig_obj)) {
-                       CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope, fbc);
-               }
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
+}
 
-       if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_STATIC) != 0)) {
-               obj = NULL;
-       } else {
-               GC_REFCOUNT(obj)++; /* For $this pointer */
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_OR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
+}
 
-       EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
-               fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_AND_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       zval_ptr_dtor_nogc(free_op2);
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
 }
 
-static int ZEND_FASTCALL  ZEND_CASE_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op2;
-       zval *result = EX_VAR(opline->result.var);
+       zval *container;
 
        SAVE_OPLINE();
-       fast_equal_function(result,
-                _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-                _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
-
+       container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+       zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op2);
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
-       zval *expr_ptr, new_expr;
+       zend_free_op free_op1, free_op2;
+       zval *container;
 
        SAVE_OPLINE();
-       if ((IS_CV == IS_VAR || IS_CV == IS_CV) &&
-           (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
-               expr_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-               if (IS_CV == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
-               }
-               ZVAL_MAKE_REF(expr_ptr);
-               Z_ADDREF_P(expr_ptr);
-
-       } else {
-               expr_ptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-               if (IS_CV == IS_TMP_VAR) {
-                       ZVAL_COPY_VALUE(&new_expr, expr_ptr);
-                       expr_ptr = &new_expr;
-               } else if (IS_CV == IS_CONST) {
-                       if (!Z_IMMUTABLE_P(expr_ptr)) {
-                               ZVAL_DUP(&new_expr, expr_ptr);
-                               expr_ptr = &new_expr;
-                       }
-               } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(expr_ptr)) {
-                       expr_ptr = Z_REFVAL_P(expr_ptr);
-                       if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
+       container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
 
-               } else if (IS_CV == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
-                       Z_ADDREF_P(expr_ptr);
-               }
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-
-       if (IS_TMP_VAR != IS_UNUSED) {
-               zend_free_op free_op2;
-               zval *offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
-               zend_string *str;
-               zend_ulong hval;
-
-add_again:
-               switch (Z_TYPE_P(offset)) {
-                       case IS_DOUBLE:
-                               hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                               goto num_index;
-                       case IS_LONG:
-                               hval = Z_LVAL_P(offset);
-num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
-                               break;
-                       case IS_STRING:
-                               str = Z_STR_P(offset);
-                               if (IS_TMP_VAR != IS_CONST) {
-                                       if (ZEND_HANDLE_NUMERIC(str, hval)) {
-                                               goto num_index;
-                                       }
-                               }
-str_index:
-                               zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
-                               break;
-                       case IS_NULL:
-                               str = STR_EMPTY_ALLOC();
-                               goto str_index;
-                       case IS_FALSE:
-                               hval = 0;
-                               goto num_index;
-                       case IS_TRUE:
-                               hval = 1;
-                               goto num_index;
-                       case IS_REFERENCE:
-                               offset = Z_REFVAL_P(offset);
-                               goto add_again;
-                               break;
-                       default:
-                               zend_error(E_WARNING, "Illegal offset type");
-                               zval_ptr_dtor(expr_ptr);
-                               /* do nothing */
-                               break;
-               }
-               zval_ptr_dtor_nogc(free_op2);
-       } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
+       ZVAL_DEREF(container);
+       zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
+       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zval *array;
-       uint32_t size;
        USE_OPLINE
+       zend_free_op free_op1, free_op2;
+       zval *container;
 
-       array = EX_VAR(opline->result.var);
-       if (IS_CV != IS_UNUSED) {
-               size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
-       } else {
-               size = 0;
-       }
-       ZVAL_NEW_ARR(array);
-       zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
+       SAVE_OPLINE();
+       container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
 
-       if (IS_CV != IS_UNUSED) {
-               /* Explicitly initialize array as not-packed if flag is set */
-               if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
-                       zend_hash_real_init(Z_ARRVAL_P(array), 0);
-               }
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-
-       if (IS_CV == IS_UNUSED) {
-               ZEND_VM_NEXT_OPCODE();
-#if 0 || IS_CV != IS_UNUSED
-       } else {
-               return ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-#endif
+       ZVAL_DEREF(container);
+       zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
+       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op2;
        zval *container;
-       zval *offset;
-       zend_ulong hval;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
-       }
-       if (IS_CV != IS_UNUSED) {
-               ZVAL_DEREF(container);
-       }
-       SEPARATE_ZVAL_NOREF(container);
-       offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       container = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
+       zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
 
-       if (IS_CV != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
-               HashTable *ht = Z_ARRVAL_P(container);
-offset_again:
-               switch (Z_TYPE_P(offset)) {
-                       case IS_DOUBLE:
-                               hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                               zend_hash_index_del(ht, hval);
-                               break;
-                       case IS_LONG:
-                               hval = Z_LVAL_P(offset);
-num_index_dim:
-                               zend_hash_index_del(ht, hval);
-                               break;
-                       case IS_STRING:
-                               if (IS_TMP_VAR != IS_CONST) {
-                                       if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
-                                               goto num_index_dim;
-                                       }
-                               }
-                               if (ht == &EG(symbol_table).ht) {
-                                       zend_delete_global_variable(Z_STR_P(offset) TSRMLS_CC);
-                               } else {
-                                       zend_hash_del(ht, Z_STR_P(offset));
-                               }
-                               break;
-                       case IS_NULL:
-                               zend_hash_del(ht, STR_EMPTY_ALLOC());
-                               break;
-                       case IS_FALSE:
-                               hval = 0;
-                               goto num_index_dim;
-                       case IS_TRUE:
-                               hval = 1;
-                               goto num_index_dim;
-                       case IS_RESOURCE:
-                               hval = Z_RES_HANDLE_P(offset);
-                               goto num_index_dim;
-                       case IS_REFERENCE:
-                               offset = Z_REFVAL_P(offset);
-                               goto offset_again;
-                               break;
-                       default:
-                               zend_error(E_WARNING, "Illegal offset type in unset");
-                               break;
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zval *container;
+       zend_free_op free_op1, free_op2;
+
+       SAVE_OPLINE();
+
+       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+        if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
+            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+        }
+               container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               zval_ptr_dtor_nogc(free_op2);
-       } else if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use object as array");
+               ZVAL_DEREF(container);
+               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
+               if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
                }
-//???          if (IS_TMP_VAR == IS_CONST) {
-//???                  zval_copy_ctor(offset);
-//???          }
-               Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
                zval_ptr_dtor_nogc(free_op2);
-       } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
-               ZEND_VM_CONTINUE(); /* bailed out before */
+
        } else {
+               if (IS_TMP_VAR == IS_UNUSED) {
+                       zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
+               }
+               container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
                zval_ptr_dtor_nogc(free_op2);
-       }
 
+       }
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_UNSET_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
+       zend_free_op free_op1, free_op2;
        zval *container;
-       zval *offset;
 
        SAVE_OPLINE();
        container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
-       }
-       offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
 
-       if (IS_CV != IS_UNUSED) {
-               ZVAL_DEREF(container);
-       }
-       if (IS_CV == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
-               if (Z_OBJ_HT_P(container)->unset_property) {
-                       Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
-               } else {
-                       zend_error(E_NOTICE, "Trying to unset property of non-object");
-               }
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
+       ZVAL_DEREF(container);
+       zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2), IS_TMP_VAR TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op2);
+       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+       }
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
-       zval *container;
-       int result;
-       zend_ulong hval;
-       zval *offset;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
-       offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
 
-       if (IS_CV != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
-               HashTable *ht = Z_ARRVAL_P(container);
-               zval *value;
-               zend_string *str;
+       zval *object_ptr;
 
-isset_again:
-               if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
-                       str = Z_STR_P(offset);
-                       if (IS_TMP_VAR != IS_CONST) {
-                               if (ZEND_HANDLE_NUMERIC(str, hval)) {
-                                       goto num_index_prop;
-                               }
-                       }
-str_index_prop:
-                       value = zend_hash_find_ind(ht, str);
-               } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
-                       hval = Z_LVAL_P(offset);
-num_index_prop:
-                       value = zend_hash_index_find(ht, hval);
-               } else {
-                       switch (Z_TYPE_P(offset)) {
-                               case IS_DOUBLE:
-                                       hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                                       goto num_index_prop;
-                               case IS_NULL:
-                                       str = STR_EMPTY_ALLOC();
-                                       goto str_index_prop;
-                               case IS_FALSE:
-                                       hval = 0;
-                                       goto num_index_prop;
-                               case IS_TRUE:
-                                       hval = 1;
-                                       goto num_index_prop;
-                               case IS_RESOURCE:
-                                       hval = Z_RES_HANDLE_P(offset);
-                                       goto num_index_prop;
-                               case IS_REFERENCE:
-                                       offset = Z_REFVAL_P(offset);
-                                       goto isset_again;
-                               default:
-                                       zend_error(E_WARNING, "Illegal offset type in isset or empty");
-                                       value = NULL;
-                                       break;
-                       }
-               }
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
 
-               if (opline->extended_value & ZEND_ISSET) {
-                       /* > IS_NULL means not IS_UNDEF and not IS_NULL */
-                       result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
-               }
-       } else if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
-                       result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
-               } else {
-                       zend_error(E_NOTICE, "Trying to check element of non-array");
-                       result = 0;
-               }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
-               }
-       } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
-               zval tmp;
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+       }
+       ZVAL_DEREF(object_ptr);
+       if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
+               zend_free_op free_op2;
+               zval *property_name = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
 
-               result = 0;
-               if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
-                       if (IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) {
-                               ZVAL_DEREF(offset);
-                       }
-                       if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
-                                       || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
-                                               && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
-                               ZVAL_DUP(&tmp, offset);
-                               convert_to_long(&tmp);
-                               offset = &tmp;
-                       }
-               }
-               if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
-                       if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
-                               if ((opline->extended_value & ZEND_ISSET) ||
-                                   Z_STRVAL_P(container)[offset->value.lval] != '0') {
-                                       result = 1;
+               zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+               zval_ptr_dtor_nogc(free_op2);
+       } else {
+               zend_free_op free_op2, free_op_data1;
+               zval  rv;
+               zval *value;
+               zval *dim = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+               zval *variable_ptr;
+
+               if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
+                   EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
+                       zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
+                       zval_ptr_dtor_nogc(free_op2);
+                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+                       zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
+                       FREE_OP(free_op_data1);
+               } else {
+                       zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_TMP_VAR TSRMLS_CC);
+                       zval_ptr_dtor_nogc(free_op2);
+                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+                       ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+                       variable_ptr = Z_INDIRECT(rv);
+                       if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
+                               FREE_OP(free_op_data1);
+                               if (RETURN_VALUE_USED(opline)) {
+                                       ZVAL_NULL(EX_VAR(opline->result.var));
+                               }
+                       } else {
+                               value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
+                               if ((opline+1)->op1_type == IS_VAR) {
+                                       FREE_OP(free_op_data1);
+                               }
+                               if (RETURN_VALUE_USED(opline)) {
+                                       ZVAL_COPY(EX_VAR(opline->result.var), value);
                                }
                        }
                }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
-               }
-       } else {
-               result = ((opline->extended_value & ZEND_ISSET) == 0);
        }
 
-       zval_ptr_dtor_nogc(free_op2);
-       ZVAL_BOOL(EX_VAR(opline->result.var), result);
-
+       /* assign_dim has two opcodes! */
        CHECK_EXCEPTION();
+       ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op2;
-       zval *container;
-       int result;
-       zval *offset;
+       zval *value;
+       zval *variable_ptr;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
-       offset = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       value = _get_zval_ptr_tmp(opline->op2.var, execute_data, &free_op2);
+       variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
-                       result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_TMP_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
-               } else {
-                       zend_error(E_NOTICE, "Trying to check property of non-object");
-                       result = 0;
+       if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
+               if (IS_TMP_VAR == IS_TMP_VAR) {
+                       zval_ptr_dtor_nogc(free_op2);
                }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
                }
        } else {
-               result = ((opline->extended_value & ZEND_ISSET) == 0);
+               value = zend_assign_to_variable(variable_ptr, value, IS_TMP_VAR TSRMLS_CC);
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_COPY(EX_VAR(opline->result.var), value);
+               }
+
        }
 
-       zval_ptr_dtor_nogc(free_op2);
-       ZVAL_BOOL(EX_VAR(opline->result.var), result);
+       /* zend_assign_to_variable() always takes care of op2, never free it! */
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
@@ -38330,456 +32222,855 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_VAR(int (*bina
                FREE_OP(free_op_data1);
        }
 
-       /* assign_obj has two opcodes! */
+       /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
+       ZEND_VM_INC_OPCODE();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_CV_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op2, free_op_data1;
+       zval *var_ptr, rv;
+       zval *value, *container;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+       }
+       if (IS_CV != IS_UNUSED) {
+               ZVAL_DEREF(container);
+       }
+       if (IS_CV == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+               if (IS_CV == IS_VAR && !0) {
+                       Z_ADDREF_P(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
+               }
+               return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else {
+               zval *dim = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+
+               zend_fetch_dimension_address_RW(&rv, container, dim, IS_VAR TSRMLS_CC);
+               value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+               ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+               var_ptr = Z_INDIRECT(rv);
+       }
+
+       if (UNEXPECTED(var_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
+       }
+
+       if (UNEXPECTED(var_ptr == &EG(error_zval))) {
+               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
+       } else {
+               ZVAL_DEREF(var_ptr);
+               SEPARATE_ZVAL_NOREF(var_ptr);
+
+               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
+
+               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+               }
+       }
+
+       zval_ptr_dtor_nogc(free_op2);
+       FREE_OP(free_op_data1);
+
+       CHECK_EXCEPTION();
+       ZEND_VM_INC_OPCODE();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op2;
+       zval *var_ptr;
+       zval *value;
+
+       SAVE_OPLINE();
+       value = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+       var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
+       }
+
+       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
+       } else {
+               ZVAL_DEREF(var_ptr);
+               SEPARATE_ZVAL_NOREF(var_ptr);
+
+               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
+
+               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+               }
+       }
+
+       zval_ptr_dtor_nogc(free_op2);
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_ASSIGN_ADD_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
+
+static int ZEND_FASTCALL  ZEND_ASSIGN_SUB_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
+
+static int ZEND_FASTCALL  ZEND_ASSIGN_MUL_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
+
+static int ZEND_FASTCALL  ZEND_ASSIGN_DIV_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
+
+static int ZEND_FASTCALL  ZEND_ASSIGN_MOD_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
+
+static int ZEND_FASTCALL  ZEND_ASSIGN_SL_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
+
+static int ZEND_FASTCALL  ZEND_ASSIGN_SR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
+
+static int ZEND_FASTCALL  ZEND_ASSIGN_CONCAT_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
+
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_OR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
+
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_AND_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
+
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
+
+static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CV_VAR(int type, ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       zval *varname;
+       zval *retval;
+       zend_string *name;
+       HashTable *target_symbol_table;
+
+       SAVE_OPLINE();
+       varname = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_CONST) {
+               name = Z_STR_P(varname);
+       } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
+               name = Z_STR_P(varname);
+               zend_string_addref(name);
+       } else {
+               name = zval_get_string(varname);
+       }
+
+       if (IS_VAR != IS_UNUSED) {
+               zend_class_entry *ce;
+
+               if (IS_VAR == IS_CONST) {
+                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+                       } else {
+                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+                               if (UNEXPECTED(ce == NULL)) {
+                                       if (IS_CV != IS_CONST) {
+                                               zend_string_release(name);
+                                       }
+
+                                       CHECK_EXCEPTION();
+                                       ZEND_VM_NEXT_OPCODE();
+                               }
+                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+                       }
+               } else {
+                       ce = Z_CE_P(EX_VAR(opline->op2.var));
+               }
+               retval = zend_std_get_static_property(ce, name, 0, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+
+       } else {
+               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+               retval = zend_hash_find(target_symbol_table, name);
+               if (retval == NULL) {
+                       switch (type) {
+                               case BP_VAR_R:
+                               case BP_VAR_UNSET:
+                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                       /* break missing intentionally */
+                               case BP_VAR_IS:
+                                       retval = &EG(uninitialized_zval);
+                                       break;
+                               case BP_VAR_RW:
+                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                       /* break missing intentionally */
+                               case BP_VAR_W:
+                                       retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
+                                       break;
+                               EMPTY_SWITCH_DEFAULT_CASE()
+                       }
+               /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
+               } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
+                       retval = Z_INDIRECT_P(retval);
+                       if (Z_TYPE_P(retval) == IS_UNDEF) {
+                               switch (type) {
+                                       case BP_VAR_R:
+                                       case BP_VAR_UNSET:
+                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                               /* break missing intentionally */
+                                       case BP_VAR_IS:
+                                               retval = &EG(uninitialized_zval);
+                                               break;
+                                       case BP_VAR_RW:
+                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                               /* break missing intentionally */
+                                       case BP_VAR_W:
+                                               ZVAL_NULL(retval);
+                                               break;
+                                       EMPTY_SWITCH_DEFAULT_CASE()
+                               }
+                       }
+               }
+               if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
+                       if (Z_CONSTANT_P(retval)) {
+                               zval_update_constant(retval, 1 TSRMLS_CC);
+                       }
+               } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
+
+               }
+       }
+
+       if (IS_CV != IS_CONST) {
+               zend_string_release(name);
+       }
+
+       ZEND_ASSERT(retval != NULL);
+       if (type == BP_VAR_R || type == BP_VAR_IS) {
+               if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
+                       ZVAL_UNREF(retval);
+               }
+               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+       } else {
+               ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
+       }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_FETCH_R_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL  ZEND_FETCH_W_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL  ZEND_FETCH_RW_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL  ZEND_FETCH_FUNC_ARG_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+               return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else {
+               return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
+
+static int ZEND_FASTCALL  ZEND_FETCH_UNSET_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL  ZEND_FETCH_IS_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op2;
+       zval *container;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+       zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
+
        CHECK_EXCEPTION();
-       ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_CV_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2, free_op_data1;
-       zval *var_ptr, rv;
-       zval *value, *container;
+       zend_free_op free_op1, free_op2;
+       zval *container;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+       container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+
        if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       if (IS_CV != IS_UNUSED) {
-               ZVAL_DEREF(container);
-       }
-       if (IS_CV == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (IS_CV == IS_VAR && !0) {
-                       Z_ADDREF_P(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
-               }
-               return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else {
-               zval *dim = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
-
-               zend_fetch_dimension_address_RW(&rv, container, dim, IS_VAR TSRMLS_CC);
-               value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-               ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
-               var_ptr = Z_INDIRECT(rv);
+       ZVAL_DEREF(container);
+       zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
+       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
 
-       if (UNEXPECTED(var_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
-       }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       if (UNEXPECTED(var_ptr == &EG(error_zval))) {
-               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
-               }
-       } else {
-               ZVAL_DEREF(var_ptr);
-               SEPARATE_ZVAL_NOREF(var_ptr);
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1, free_op2;
+       zval *container;
 
-               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
+       SAVE_OPLINE();
+       container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
 
-               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
-               }
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-
+       ZVAL_DEREF(container);
+       zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
        zval_ptr_dtor_nogc(free_op2);
-       FREE_OP(free_op_data1);
+       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+       }
 
        CHECK_EXCEPTION();
-       ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op2;
-       zval *var_ptr;
-       zval *value;
+       zval *container;
 
        SAVE_OPLINE();
-       value = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
-       var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+       container = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
+       zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
 
-       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
-       }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
-               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
-               }
-       } else {
-               ZVAL_DEREF(var_ptr);
-               SEPARATE_ZVAL_NOREF(var_ptr);
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zval *container;
+       zend_free_op free_op1, free_op2;
 
-               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
+       SAVE_OPLINE();
 
-               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+        if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
+            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+        }
+               container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-       }
+               ZVAL_DEREF(container);
+               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+               if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+               }
+               zval_ptr_dtor_nogc(free_op2);
 
-       zval_ptr_dtor_nogc(free_op2);
+       } else {
+               if (IS_VAR == IS_UNUSED) {
+                       zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
+               }
+               container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+               zval_ptr_dtor_nogc(free_op2);
 
+       }
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_ADD_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_UNSET_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zend_free_op free_op1, free_op2;
+       zval *container;
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       SAVE_OPLINE();
+       container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+       }
+       ZVAL_DEREF(container);
+       zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
+       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SUB_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
+       zval *object_ptr;
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_MUL_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-}
+       ZVAL_DEREF(object_ptr);
+       if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
+               zend_free_op free_op2;
+               zval *property_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_DIV_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+               zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+               zval_ptr_dtor_nogc(free_op2);
+       } else {
+               zend_free_op free_op2, free_op_data1;
+               zval  rv;
+               zval *value;
+               zval *dim = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+               zval *variable_ptr;
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
+                   EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
+                       zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
+                       zval_ptr_dtor_nogc(free_op2);
+                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+                       zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
+                       FREE_OP(free_op_data1);
+               } else {
+                       zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_VAR TSRMLS_CC);
+                       zval_ptr_dtor_nogc(free_op2);
+                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+                       ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+                       variable_ptr = Z_INDIRECT(rv);
+                       if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
+                               FREE_OP(free_op_data1);
+                               if (RETURN_VALUE_USED(opline)) {
+                                       ZVAL_NULL(EX_VAR(opline->result.var));
+                               }
+                       } else {
+                               value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
+                               if ((opline+1)->op1_type == IS_VAR) {
+                                       FREE_OP(free_op_data1);
+                               }
+                               if (RETURN_VALUE_USED(opline)) {
+                                       ZVAL_COPY(EX_VAR(opline->result.var), value);
+                               }
+                       }
+               }
        }
+
+       /* assign_dim has two opcodes! */
+       CHECK_EXCEPTION();
+       ZEND_VM_INC_OPCODE();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_MOD_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zend_free_op free_op2;
+       zval *value;
+       zval *variable_ptr;
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
+       SAVE_OPLINE();
+       value = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
+       variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SL_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
+               if (IS_VAR == IS_TMP_VAR) {
+                       zval_ptr_dtor_nogc(free_op2);
+               }
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
+       } else {
+               value = zend_assign_to_variable(variable_ptr, value, IS_VAR TSRMLS_CC);
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_COPY(EX_VAR(opline->result.var), value);
+               }
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
-}
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       /* zend_assign_to_variable() always takes care of op2, never free it! */
+       zval_ptr_dtor_nogc(free_op2);
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_CONCAT_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_REF_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zend_free_op free_op2;
+       zval *variable_ptr;
+       zval *value_ptr;
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
+       SAVE_OPLINE();
+       value_ptr = _get_zval_ptr_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_OR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       if (IS_VAR == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
+       }
+       if (IS_VAR == IS_VAR &&
+           (value_ptr == &EG(uninitialized_zval) ||
+            (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+             !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+               if (!(free_op2 != NULL)) {
+                       PZVAL_LOCK(value_ptr); /* undo the effect of get_zval_ptr_ptr() */
+               }
+               zend_error(E_STRICT, "Only variables should be assigned by reference");
+               if (UNEXPECTED(EG(exception) != NULL)) {
+                       if (free_op2) {zval_ptr_dtor_nogc(free_op2);};
+                       HANDLE_EXCEPTION();
+               }
+               return ZEND_ASSIGN_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (IS_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
+               if (!(free_op2 != NULL)) {
+                       PZVAL_LOCK(value_ptr);
+               }
+       }
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+       if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
+       }
+       if (IS_CV == IS_VAR &&
+           UNEXPECTED(Z_TYPE_P(EX_VAR(opline->op1.var)) != IS_INDIRECT) &&
+           UNEXPECTED(!Z_ISREF_P(variable_ptr))) {
+               zend_error_noreturn(E_ERROR, "Cannot assign by reference to overloaded object");
+       }
+       if ((IS_CV == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) ||
+           (IS_VAR == IS_VAR && UNEXPECTED(value_ptr == &EG(error_zval)))) {
+               variable_ptr = &EG(uninitialized_zval);
+       } else {
+               zend_assign_to_variable_reference(variable_ptr, value_ptr TSRMLS_CC);
        }
-}
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_AND_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       if (IS_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
+               if (!(free_op2 != NULL)) {
+                       Z_DELREF_P(variable_ptr);
+               }
+       }
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       if (RETURN_VALUE_USED(opline)) {
+               ZVAL_COPY(EX_VAR(opline->result.var), variable_ptr);
        }
-}
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       if (free_op2) {zval_ptr_dtor_nogc(free_op2);};
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_VAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
-       zval *object;
-       zval *property;
-       zval *retval;
-       zval *zptr;
+       zval tmp, *varname;
+       HashTable *target_symbol_table;
 
-       SAVE_OPLINE();
-       object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
-       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-       retval = EX_VAR(opline->result.var);
 
-       if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
-       }
+       SAVE_OPLINE();
+       if (IS_CV == IS_CV &&
+           IS_VAR == IS_UNUSED &&
+           (opline->extended_value & ZEND_QUICK_SET)) {
+               zval *var = EX_VAR(opline->op1.var);
 
-       if (IS_CV != IS_UNUSED) {
-               object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
-       }
+               if (Z_REFCOUNTED_P(var)) {
+                       zend_refcounted *garbage = Z_COUNTED_P(var);
 
-       if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
-               zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-               zval_ptr_dtor_nogc(free_op2);
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(retval);
+                       if (!--GC_REFCOUNT(garbage)) {
+                               ZVAL_UNDEF(var);
+                               _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
+                       } else {
+                               GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
+                               ZVAL_UNDEF(var);
+                       }
+               } else {
+                       ZVAL_UNDEF(var);
                }
-
                CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
-       /* here we are sure we are dealing with an object */
-
-       if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
-
-               ZVAL_DEREF(zptr);
-               SEPARATE_ZVAL_NOREF(zptr);
+       varname = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
 
-               incdec_op(zptr);
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_COPY(retval, zptr);
-               }
-       } else {
-               zval rv;
+       ZVAL_UNDEF(&tmp);
+       if (IS_CV != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
+               ZVAL_STR(&tmp, zval_get_string(varname));
+               varname = &tmp;
+       }
 
-               if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
-                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+       if (IS_VAR != IS_UNUSED) {
+               zend_class_entry *ce;
 
-                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
-                               zval rv;
-                               zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+               if (IS_VAR == IS_CONST) {
+                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+                       } else {
+                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+                               if (UNEXPECTED(EG(exception) != NULL)) {
+                                       if (IS_CV != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+                                               zend_string_release(Z_STR(tmp));
+                                       }
 
-                               if (Z_REFCOUNT_P(z) == 0) {
-                                       zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
+                                       HANDLE_EXCEPTION();
                                }
-                               ZVAL_COPY_VALUE(z, value);
+                               if (UNEXPECTED(ce == NULL)) {
+                                       zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
+                               }
+                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
                        }
-                       if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
-                       SEPARATE_ZVAL_IF_NOT_REF(z);
-                       incdec_op(z);
-                       ZVAL_COPY_VALUE(retval, z);
-                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
-                       SELECTIVE_PZVAL_LOCK(retval, opline);
-                       zval_ptr_dtor(z);
                } else {
-                       zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-                       if (RETURN_VALUE_USED(opline)) {
-                               ZVAL_NULL(retval);
-                       }
+                       ce = Z_CE_P(EX_VAR(opline->op2.var));
                }
+               zend_std_unset_static_property(ce, Z_STR_P(varname), ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+       } else {
+               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+               zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
        }
 
-       zval_ptr_dtor_nogc(free_op2);
+       if (IS_CV != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+               zend_string_release(Z_STR(tmp));
+       }
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_PRE_INC_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_pre_incdec_property_helper_SPEC_CV_VAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_pre_incdec_property_helper_SPEC_CV_VAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_VAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
-       zval *object;
-       zval *property;
-       zval *retval;
-       zval *zptr;
+       zval *value;
 
        SAVE_OPLINE();
-       object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
-       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-       retval = EX_VAR(opline->result.var);
-
-       if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
-       }
-
-       if (IS_CV != IS_UNUSED) {
-               object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
-       }
-
-       if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
-               zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-               zval_ptr_dtor_nogc(free_op2);
-               ZVAL_NULL(retval);
-
-               CHECK_EXCEPTION();
+       if (IS_CV == IS_CV &&
+           IS_VAR == IS_UNUSED &&
+           (opline->extended_value & ZEND_QUICK_SET)) {
+               value = EX_VAR(opline->op1.var);
+               if (opline->extended_value & ZEND_ISSET) {
+                       ZVAL_BOOL(EX_VAR(opline->result.var),
+                               Z_TYPE_P(value) > IS_NULL &&
+                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+                       ZVAL_BOOL(EX_VAR(opline->result.var),
+                               !i_zend_is_true(value TSRMLS_CC));
+                       CHECK_EXCEPTION();
+               }
                ZEND_VM_NEXT_OPCODE();
-       }
-
-       /* here we are sure we are dealing with an object */
-
-       if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+       } else {
 
-               ZVAL_DEREF(zptr);
-               ZVAL_COPY_VALUE(retval, zptr);
-               zval_opt_copy_ctor(zptr);
+               zval tmp, *varname = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
 
-               incdec_op(zptr);
-       } else {
-               if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
-                       zval rv;
-                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
-                       zval z_copy;
+               ZVAL_UNDEF(&tmp);
+               if (IS_CV != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
+                       ZVAL_STR(&tmp, zval_get_string(varname));
+                       varname = &tmp;
+               }
 
-                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
-                               zval rv;
-                               zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+               if (IS_VAR != IS_UNUSED) {
+                       zend_class_entry *ce;
 
-                               if (Z_REFCOUNT_P(z) == 0) {
-                                       zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
+                       if (IS_VAR == IS_CONST) {
+                               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                                       ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+                               } else {
+                                       ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+                                       if (UNEXPECTED(ce == NULL)) {
+                                               CHECK_EXCEPTION();
+                                               ZEND_VM_NEXT_OPCODE();
+                                       }
+                                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
                                }
-                               ZVAL_COPY_VALUE(z, value);
+                       } else {
+                               ce = Z_CE_P(EX_VAR(opline->op2.var));
                        }
-                       ZVAL_DUP(retval, z);
-                       ZVAL_DUP(&z_copy, z);
-                       incdec_op(&z_copy);
-                       if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
-                       Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
-                       zval_ptr_dtor(&z_copy);
-                       zval_ptr_dtor(z);
+                       value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
                } else {
-                       zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-                       ZVAL_NULL(retval);
+                       HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+                       value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
                }
-       }
-
-       zval_ptr_dtor_nogc(free_op2);
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+               if (IS_CV != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+                       zend_string_release(Z_STR(tmp));
+               }
 
-static int ZEND_FASTCALL  ZEND_POST_INC_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_post_incdec_property_helper_SPEC_CV_VAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+               if (opline->extended_value & ZEND_ISSET) {
+                       ZVAL_BOOL(EX_VAR(opline->result.var),
+                               value && Z_TYPE_P(value) > IS_NULL &&
+                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+                       ZVAL_BOOL(EX_VAR(opline->result.var),
+                               !value || !i_zend_is_true(value TSRMLS_CC));
+               }
 
-static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_post_incdec_property_helper_SPEC_CV_VAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
+       }
 }
 
-static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CV_VAR(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INSTANCEOF_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *varname;
-       zval *retval;
-       zend_string *name;
-       HashTable *target_symbol_table;
+       zval *expr;
+       zend_bool result;
 
        SAVE_OPLINE();
-       varname = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-
-       if (IS_CV == IS_CONST) {
-               name = Z_STR_P(varname);
-       } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
-               name = Z_STR_P(varname);
-               zend_string_addref(name);
-       } else {
-               name = zval_get_string(varname);
-       }
+       expr = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
 
-       if (IS_VAR != IS_UNUSED) {
+       if (Z_TYPE_P(expr) == IS_OBJECT) {
                zend_class_entry *ce;
 
                if (IS_VAR == IS_CONST) {
                        if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
                                ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
                        } else {
-                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, ZEND_FETCH_CLASS_NO_AUTOLOAD TSRMLS_CC);
                                if (UNEXPECTED(ce == NULL)) {
-                                       if (IS_CV != IS_CONST) {
-                                               zend_string_release(name);
-                                       }
+                                       ZVAL_FALSE(EX_VAR(opline->result.var));
 
                                        CHECK_EXCEPTION();
                                        ZEND_VM_NEXT_OPCODE();
@@ -38789,767 +33080,785 @@ static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CV_VAR(int type, ZEN
                } else {
                        ce = Z_CE_P(EX_VAR(opline->op2.var));
                }
-               retval = zend_std_get_static_property(ce, name, 0, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
-
+               result = instanceof_function(Z_OBJCE_P(expr), ce TSRMLS_CC);
        } else {
-               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-               retval = zend_hash_find(target_symbol_table, name);
-               if (retval == NULL) {
-                       switch (type) {
-                               case BP_VAR_R:
-                               case BP_VAR_UNSET:
-                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                       /* break missing intentionally */
-                               case BP_VAR_IS:
-                                       retval = &EG(uninitialized_zval);
-                                       break;
-                               case BP_VAR_RW:
-                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                       /* break missing intentionally */
-                               case BP_VAR_W:
-                                       retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
-                                       break;
-                               EMPTY_SWITCH_DEFAULT_CASE()
-                       }
-               /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
-               } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
-                       retval = Z_INDIRECT_P(retval);
-                       if (Z_TYPE_P(retval) == IS_UNDEF) {
-                               switch (type) {
-                                       case BP_VAR_R:
-                                       case BP_VAR_UNSET:
-                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                               /* break missing intentionally */
-                                       case BP_VAR_IS:
-                                               retval = &EG(uninitialized_zval);
-                                               break;
-                                       case BP_VAR_RW:
-                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                               /* break missing intentionally */
-                                       case BP_VAR_W:
-                                               ZVAL_NULL(retval);
-                                               break;
-                                       EMPTY_SWITCH_DEFAULT_CASE()
-                               }
-                       }
-               }
-               if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
-                       if (Z_CONSTANT_P(retval)) {
-                               zval_update_constant(retval, 1 TSRMLS_CC);
-                       }
-               } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
-
-               }
-       }
-
-       if (IS_CV != IS_CONST) {
-               zend_string_release(name);
+               result = 0;
        }
+       ZVAL_BOOL(EX_VAR(opline->result.var), result);
 
-       ZEND_ASSERT(retval != NULL);
-       if (type == BP_VAR_R || type == BP_VAR_IS) {
-               if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
-                       ZVAL_UNREF(retval);
-               }
-               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-       } else {
-               ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
-       }
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_R_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_YIELD_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+       USE_OPLINE
 
-static int ZEND_FASTCALL  ZEND_FETCH_W_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+       /* The generator object is stored in EX(return_value) */
+       zend_generator *generator = (zend_generator *) EX(return_value);
 
-static int ZEND_FASTCALL  ZEND_FETCH_RW_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+       if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
+               zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
+       }
 
-static int ZEND_FASTCALL  ZEND_FETCH_FUNC_ARG_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       /* Destroy the previously yielded value */
+       zval_ptr_dtor(&generator->value);
 
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-               return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else {
-               return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
+       /* Destroy the previously yielded key */
+       zval_ptr_dtor(&generator->key);
 
-static int ZEND_FASTCALL  ZEND_FETCH_UNSET_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+       /* Set the new yielded value */
+       if (IS_CV != IS_UNUSED) {
 
-static int ZEND_FASTCALL  ZEND_FETCH_IS_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_CV_VAR(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
-       zval *container;
+               if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
+                       /* Constants and temporary variables aren't yieldable by reference,
+                        * but we still allow them with a notice. */
+                       if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
+                               zval *value;
 
-       SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-       zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
+                               zend_error(E_NOTICE, "Only variable references should be yielded by reference");
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+                               value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+                               ZVAL_COPY_VALUE(&generator->value, value);
+                               if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1, free_op2;
-       zval *container;
+                               /* Temporary variables don't need ctor copying */
+                               if (IS_CV != IS_TMP_VAR) {
+                                       zval_opt_copy_ctor(&generator->value);
+                               }
+                       } else {
+                               zval *value_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
 
-       SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+                               if (IS_CV == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+                                       zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
+                               }
 
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-       }
-       ZVAL_DEREF(container);
-       zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
-       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-       }
+                               /* If a function call result is yielded and the function did
+                                * not return by reference we throw a notice. */
+                               if (IS_CV == IS_VAR &&
+                                   (value_ptr == &EG(uninitialized_zval) ||
+                                    (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+                                     !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+                                       zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+                               } else {
+                                       ZVAL_MAKE_REF(value_ptr);
+                               }
+                               ZVAL_COPY(&generator->value, value_ptr);
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+                       }
+               } else {
+                       zval *value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1, free_op2;
-       zval *container;
+                       /* Consts, temporary variables and references need copying */
+                       if (IS_CV == IS_CONST) {
+                               ZVAL_DUP(&generator->value, value);
+                       } else if (IS_CV == IS_TMP_VAR) {
+                               ZVAL_COPY_VALUE(&generator->value, value);
+            } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(value)) {
+                               ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
 
-       SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+                       } else {
+                               ZVAL_COPY_VALUE(&generator->value, value);
+                               if (IS_CV == IS_CV) {
+                                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+                               }
+                       }
+               }
+       } else {
+               /* If no value was specified yield null */
+               ZVAL_NULL(&generator->value);
+       }
 
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+       /* Set the new yielded key */
+       if (IS_VAR != IS_UNUSED) {
+               zend_free_op free_op2;
+               zval *key = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+
+               /* Consts, temporary variables and references need copying */
+               if (IS_VAR == IS_CONST) {
+                       ZVAL_DUP(&generator->key, key);
+               } else if (IS_VAR == IS_TMP_VAR) {
+                       ZVAL_COPY_VALUE(&generator->key, key);
+               } else if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && Z_ISREF_P(key)) {
+                       ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
+                       zval_ptr_dtor_nogc(free_op2);
+               } else {
+                       ZVAL_COPY_VALUE(&generator->key, key);
+                       if (IS_VAR == IS_CV) {
+                               if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
+                       }
+               }
+
+               if (Z_TYPE(generator->key) == IS_LONG
+                   && Z_LVAL(generator->key) > generator->largest_used_integer_key
+               ) {
+                       generator->largest_used_integer_key = Z_LVAL(generator->key);
+               }
+       } else {
+               /* If no key was specified we use auto-increment keys */
+               generator->largest_used_integer_key++;
+               ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
        }
-       ZVAL_DEREF(container);
-       zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
-       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+
+       if (RETURN_VALUE_USED(opline)) {
+               /* If the return value of yield is used set the send
+                * target and initialize it to NULL */
+               generator->send_target = EX_VAR(opline->result.var);
+               ZVAL_NULL(generator->send_target);
+       } else {
+               generator->send_target = NULL;
        }
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       /* We increment to the next op, so we are at the correct position when the
+        * generator is resumed. */
+       ZEND_VM_INC_OPCODE();
+
+       /* The GOTO VM uses a local opline variable. We need to set the opline
+        * variable in execute_data so we don't resume at an old position. */
+       SAVE_OPLINE();
+
+       ZEND_VM_RETURN();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_POW_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op2;
-       zval *container;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
-       zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
+       pow_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
 
+       zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_POW_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_binary_assign_op_helper_SPEC_CV_VAR(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *container;
-       zend_free_op free_op1, free_op2;
+       zend_free_op free_op_data1;
+       zval *object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+       zval *property = NULL;
+       zval *value;
+       zval *zptr;
 
-       SAVE_OPLINE();
+       if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+       }
 
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-        if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
-            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
-        }
-               container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-               }
-               ZVAL_DEREF(container);
-               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
-               if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-               }
-               zval_ptr_dtor_nogc(free_op2);
+       if (IS_CV != IS_UNUSED) {
+               object = make_real_object(object TSRMLS_CC);
+       }
+
+       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+
+       if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+               zend_error(E_WARNING, "Attempt to assign property of non-object");
 
+               FREE_OP(free_op_data1);
+
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
        } else {
-               if (IS_VAR == IS_UNUSED) {
-                       zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
+               /* here we are sure we are dealing with an object */
+               if (opline->extended_value == ZEND_ASSIGN_OBJ
+                       && EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+                       && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_UNUSED == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+
+                       ZVAL_DEREF(zptr);
+                       SEPARATE_ZVAL_NOREF(zptr);
+
+                       binary_op(zptr, zptr, value TSRMLS_CC);
+                       if (RETURN_VALUE_USED(opline)) {
+                               ZVAL_COPY(EX_VAR(opline->result.var), zptr);
+                       }
+               } else {
+                       zval *z = NULL;
+                       zval rv;
+
+                       if (opline->extended_value == ZEND_ASSIGN_OBJ) {
+                               if (Z_OBJ_HT_P(object)->read_property) {
+                                       z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_UNUSED == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+                               }
+                       } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
+                               if (Z_OBJ_HT_P(object)->read_dimension) {
+                                       z = Z_OBJ_HT_P(object)->read_dimension(object, property, BP_VAR_R, &rv TSRMLS_CC);
+                               }
+                       }
+                       if (z) {
+                               if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                                       zval rv;
+                                       zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+
+                                       if (Z_REFCOUNT_P(z) == 0) {
+                                               zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
+                                       }
+                                       ZVAL_COPY_VALUE(z, value);
+                               }
+//???                          if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
+                               SEPARATE_ZVAL_IF_NOT_REF(z);
+                               binary_op(z, z, value TSRMLS_CC);
+                               if (opline->extended_value == ZEND_ASSIGN_OBJ) {
+                                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_UNUSED == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+                               } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
+                                       Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
+                               }
+                               if (RETURN_VALUE_USED(opline)) {
+                                       ZVAL_COPY(EX_VAR(opline->result.var), z);
+                               }
+                               zval_ptr_dtor(z);
+                       } else {
+                               zend_error(E_WARNING, "Attempt to assign property of non-object");
+                               if (RETURN_VALUE_USED(opline)) {
+                                       ZVAL_NULL(EX_VAR(opline->result.var));
+                               }
+                       }
                }
-               container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op2);
 
+               FREE_OP(free_op_data1);
        }
+
+       /* assign_obj has two opcodes! */
        CHECK_EXCEPTION();
+       ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_UNSET_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
-       zval *container;
+       zend_free_op free_op_data1;
+       zval *var_ptr, rv;
+       zval *value, *container;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
-
+       container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
        if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       ZVAL_DEREF(container);
-       zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2), IS_VAR TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
-       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+       if (IS_CV != IS_UNUSED) {
+               ZVAL_DEREF(container);
+       }
+       if (IS_CV == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+               if (IS_CV == IS_VAR && !0) {
+                       Z_ADDREF_P(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
+               }
+               return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else {
+               zval *dim = NULL;
+
+               zend_fetch_dimension_address_RW(&rv, container, dim, IS_UNUSED TSRMLS_CC);
+               value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+               ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+               var_ptr = Z_INDIRECT(rv);
+       }
+
+       if (UNEXPECTED(var_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
+       }
+
+       if (UNEXPECTED(var_ptr == &EG(error_zval))) {
+               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
+       } else {
+               ZVAL_DEREF(var_ptr);
+               SEPARATE_ZVAL_NOREF(var_ptr);
+
+               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
+
+               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+               }
        }
 
+       FREE_OP(free_op_data1);
+
        CHECK_EXCEPTION();
+       ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_UNUSED(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *container;
-       zend_free_op free_op2;
-       zval *offset;
+       zval *var_ptr;
+       zval *value;
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-       offset  = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
-       if ((IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
-           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
-               zend_error(E_NOTICE, "Trying to get property of non-object");
-               ZVAL_NULL(EX_VAR(opline->result.var));
-       } else {
-               zval *retval;
+       value = NULL;
+       var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
 
-               /* here we are sure we are dealing with an object */
-               do {
-                       if (IS_VAR == IS_CONST &&
-                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
-                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
-                               zend_object *zobj = Z_OBJ_P(container);
+       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
+       }
 
-                               if (EXPECTED(prop_info)) {
-                                       retval = OBJ_PROP(zobj, prop_info->offset);
-                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               } else if (EXPECTED(zobj->properties != NULL)) {
-                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
-                                       if (EXPECTED(retval)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               }
-                       }
+       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
+               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
+       } else {
+               ZVAL_DEREF(var_ptr);
+               SEPARATE_ZVAL_NOREF(var_ptr);
 
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
 
-                       if (retval != EX_VAR(opline->result.var)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                       }
-               } while (0);
+               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
+                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+               }
        }
 
-       zval_ptr_dtor_nogc(free_op2);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_ADD_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
-       zval *property;
-       zval *container;
-
-       SAVE_OPLINE();
-       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
-       container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
-       }
 
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
-       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_UNUSED(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_SUB_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
-       zval *property;
-       zval *container;
-
-       SAVE_OPLINE();
-       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-       container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
-       }
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
-       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_UNUSED(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_MUL_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *container;
-       zend_free_op free_op2;
-       zval *offset;
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_UNUSED(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
 
-       SAVE_OPLINE();
-       container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
-       offset  = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+static int ZEND_FASTCALL  ZEND_ASSIGN_DIV_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       if ((IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
-           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
-               ZVAL_NULL(EX_VAR(opline->result.var));
-       } else {
-               zval *retval;
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_UNUSED(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
 
-               /* here we are sure we are dealing with an object */
-               do {
-                       if (IS_VAR == IS_CONST &&
-                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
-                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
-                               zend_object *zobj = Z_OBJ_P(container);
+static int ZEND_FASTCALL  ZEND_ASSIGN_MOD_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-                               if (EXPECTED(prop_info)) {
-                                       retval = OBJ_PROP(zobj, prop_info->offset);
-                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               } else if (EXPECTED(zobj->properties != NULL)) {
-                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
-                                       if (EXPECTED(retval)) {
-                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                                               break;
-                                       }
-                               }
-                       }
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_UNUSED(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
 
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+static int ZEND_FASTCALL  ZEND_ASSIGN_SL_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-                       if (retval != EX_VAR(opline->result.var)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-                       }
-               } while (0);
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_UNUSED(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
+}
 
-       zval_ptr_dtor_nogc(free_op2);
+static int ZEND_FASTCALL  ZEND_ASSIGN_SR_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_UNUSED(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_CONCAT_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *container;
-
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-               /* Behave like FETCH_OBJ_W */
-               zend_free_op free_op1, free_op2;
-               zval *property;
 
-               SAVE_OPLINE();
-               property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-               container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_UNUSED(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
 
-        if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
-            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
-        }
-               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
-               }
-               zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op2);
-               if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-               }
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_OR_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       } else {
-               return ZEND_FETCH_OBJ_R_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_UNUSED(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_AND_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1, free_op2;
-       zval *container, *property;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
-       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
-       }
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_VAR, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
-       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_UNUSED(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
-       zval *object;
-       zval *property_name;
-
-       SAVE_OPLINE();
-       object = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-       property_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_UNUSED(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
-       zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op2);
-
-       /* assign_obj has two opcodes! */
-       CHECK_EXCEPTION();
-       ZEND_VM_INC_OPCODE();
-       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CV_UNUSED(int type, ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *object_ptr;
+       zval *varname;
+       zval *retval;
+       zend_string *name;
+       HashTable *target_symbol_table;
 
        SAVE_OPLINE();
-       object_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+       varname = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+       if (IS_CV == IS_CONST) {
+               name = Z_STR_P(varname);
+       } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
+               name = Z_STR_P(varname);
+               zend_string_addref(name);
+       } else {
+               name = zval_get_string(varname);
        }
-       ZVAL_DEREF(object_ptr);
-       if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
-               zend_free_op free_op2;
-               zval *property_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-               zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op2);
-       } else {
-               zend_free_op free_op2, free_op_data1;
-               zval  rv;
-               zval *value;
-               zval *dim = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
-               zval *variable_ptr;
+       if (IS_UNUSED != IS_UNUSED) {
+               zend_class_entry *ce;
 
-               if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
-                   EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
-                       zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
-                       zval_ptr_dtor_nogc(free_op2);
-                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-                       zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
-                       FREE_OP(free_op_data1);
-               } else {
-                       zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_VAR TSRMLS_CC);
-                       zval_ptr_dtor_nogc(free_op2);
-                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-                       ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
-                       variable_ptr = Z_INDIRECT(rv);
-                       if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
-                               FREE_OP(free_op_data1);
-                               if (RETURN_VALUE_USED(opline)) {
-                                       ZVAL_NULL(EX_VAR(opline->result.var));
-                               }
+               if (IS_UNUSED == IS_CONST) {
+                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
                        } else {
-                               value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
-                               if ((opline+1)->op1_type == IS_VAR) {
-                                       FREE_OP(free_op_data1);
-                               }
-                               if (RETURN_VALUE_USED(opline)) {
-                                       ZVAL_COPY(EX_VAR(opline->result.var), value);
+                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+                               if (UNEXPECTED(ce == NULL)) {
+                                       if (IS_CV != IS_CONST) {
+                                               zend_string_release(name);
+                                       }
+
+                                       CHECK_EXCEPTION();
+                                       ZEND_VM_NEXT_OPCODE();
                                }
+                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
                        }
+               } else {
+                       ce = Z_CE_P(EX_VAR(opline->op2.var));
                }
-       }
-
-       /* assign_dim has two opcodes! */
-       CHECK_EXCEPTION();
-       ZEND_VM_INC_OPCODE();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
-       zval *value;
-       zval *variable_ptr;
-
-       SAVE_OPLINE();
-       value = _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2);
-       variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+               retval = zend_std_get_static_property(ce, name, 0, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
-               if (IS_VAR == IS_TMP_VAR) {
-                       zval_ptr_dtor_nogc(free_op2);
-               }
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
-               }
        } else {
-               value = zend_assign_to_variable(variable_ptr, value, IS_VAR TSRMLS_CC);
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_COPY(EX_VAR(opline->result.var), value);
+               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+               retval = zend_hash_find(target_symbol_table, name);
+               if (retval == NULL) {
+                       switch (type) {
+                               case BP_VAR_R:
+                               case BP_VAR_UNSET:
+                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                       /* break missing intentionally */
+                               case BP_VAR_IS:
+                                       retval = &EG(uninitialized_zval);
+                                       break;
+                               case BP_VAR_RW:
+                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                       /* break missing intentionally */
+                               case BP_VAR_W:
+                                       retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
+                                       break;
+                               EMPTY_SWITCH_DEFAULT_CASE()
+                       }
+               /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
+               } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
+                       retval = Z_INDIRECT_P(retval);
+                       if (Z_TYPE_P(retval) == IS_UNDEF) {
+                               switch (type) {
+                                       case BP_VAR_R:
+                                       case BP_VAR_UNSET:
+                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                               /* break missing intentionally */
+                                       case BP_VAR_IS:
+                                               retval = &EG(uninitialized_zval);
+                                               break;
+                                       case BP_VAR_RW:
+                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                               /* break missing intentionally */
+                                       case BP_VAR_W:
+                                               ZVAL_NULL(retval);
+                                               break;
+                                       EMPTY_SWITCH_DEFAULT_CASE()
+                               }
+                       }
                }
+               if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
+                       if (Z_CONSTANT_P(retval)) {
+                               zval_update_constant(retval, 1 TSRMLS_CC);
+                       }
+               } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
 
+               }
        }
 
-       /* zend_assign_to_variable() always takes care of op2, never free it! */
-       zval_ptr_dtor_nogc(free_op2);
+       if (IS_CV != IS_CONST) {
+               zend_string_release(name);
+       }
 
+       ZEND_ASSERT(retval != NULL);
+       if (type == BP_VAR_R || type == BP_VAR_IS) {
+               if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
+                       ZVAL_UNREF(retval);
+               }
+               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+       } else {
+               ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
+       }
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_REF_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_R_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       USE_OPLINE
-       zend_free_op free_op2;
-       zval *variable_ptr;
-       zval *value_ptr;
+       return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
 
-       SAVE_OPLINE();
-       value_ptr = _get_zval_ptr_ptr_var(opline->op2.var, execute_data, &free_op2);
+static int ZEND_FASTCALL  ZEND_FETCH_W_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
 
-       if (IS_VAR == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
-       }
-       if (IS_VAR == IS_VAR &&
-           (value_ptr == &EG(uninitialized_zval) ||
-            (opline->extended_value == ZEND_RETURNS_FUNCTION &&
-             !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
-               if (!(free_op2 != NULL)) {
-                       PZVAL_LOCK(value_ptr); /* undo the effect of get_zval_ptr_ptr() */
-               }
-               zend_error(E_STRICT, "Only variables should be assigned by reference");
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       if (free_op2) {zval_ptr_dtor_nogc(free_op2);};
-                       HANDLE_EXCEPTION();
-               }
-               return ZEND_ASSIGN_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (IS_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
-               if (!(free_op2 != NULL)) {
-                       PZVAL_LOCK(value_ptr);
-               }
-       }
+static int ZEND_FASTCALL  ZEND_FETCH_RW_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
 
-       variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-       if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
-       }
-       if (IS_CV == IS_VAR &&
-           UNEXPECTED(Z_TYPE_P(EX_VAR(opline->op1.var)) != IS_INDIRECT) &&
-           UNEXPECTED(!Z_ISREF_P(variable_ptr))) {
-               zend_error_noreturn(E_ERROR, "Cannot assign by reference to overloaded object");
-       }
-       if ((IS_CV == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) ||
-           (IS_VAR == IS_VAR && UNEXPECTED(value_ptr == &EG(error_zval)))) {
-               variable_ptr = &EG(uninitialized_zval);
+static int ZEND_FASTCALL  ZEND_FETCH_FUNC_ARG_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+               return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else {
-               zend_assign_to_variable_reference(variable_ptr, value_ptr TSRMLS_CC);
+               return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
+}
+
+static int ZEND_FASTCALL  ZEND_FETCH_UNSET_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL  ZEND_FETCH_IS_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
 
-       if (IS_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
-               if (!(free_op2 != NULL)) {
-                       Z_DELREF_P(variable_ptr);
-               }
-       }
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *container;
 
-       if (RETURN_VALUE_USED(opline)) {
-               ZVAL_COPY(EX_VAR(opline->result.var), variable_ptr);
+       SAVE_OPLINE();
+       container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
+       ZVAL_DEREF(container);
+       zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
 
-       if (free_op2) {zval_ptr_dtor_nogc(free_op2);};
+       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+       }
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *function_name;
-       zend_free_op free_op2;
-       zval *object;
-       zend_function *fbc;
-       zend_class_entry *called_scope;
-       zend_object *obj;
+       zend_free_op free_op1;
+       zval *container;
 
        SAVE_OPLINE();
+       container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
 
-       function_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
-       if (IS_VAR != IS_CONST &&
-           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       HANDLE_EXCEPTION();
-               }
-               zend_error_noreturn(E_ERROR, "Method name must be a string");
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
+       ZVAL_DEREF(container);
+       zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
 
-       object = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+       }
 
-       if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
-               uint32_t nesting = 1;
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-               if (UNEXPECTED(EG(exception) != NULL)) {
-                       zval_ptr_dtor_nogc(free_op2);
-                       HANDLE_EXCEPTION();
-               }
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zval *container;
+       zend_free_op free_op1;
 
-               zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s",  Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
-               zval_ptr_dtor_nogc(free_op2);
+       SAVE_OPLINE();
 
-               if (EG(exception) != NULL) {
-                       HANDLE_EXCEPTION();
+       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+        if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
+            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+        }
+               container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+               }
+               ZVAL_DEREF(container);
+               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
+               if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
                }
 
-               /* No exception raised: Skip over arguments until fcall opcode with correct
-                * nesting level. Return NULL (except when return value unused) */
-               do {
-                       opline++;
-                       if (opline->opcode == ZEND_INIT_FCALL ||
-                               opline->opcode == ZEND_INIT_FCALL_BY_NAME ||
-                               opline->opcode == ZEND_INIT_NS_FCALL_BY_NAME ||
-                               opline->opcode == ZEND_INIT_METHOD_CALL ||
-                               opline->opcode == ZEND_INIT_STATIC_METHOD_CALL ||
-                               opline->opcode == ZEND_INIT_USER_CALL ||
-                               opline->opcode == ZEND_NEW
-                       ) {
-                               nesting++;
-                       } else if (opline->opcode == ZEND_DO_FCALL) {
-                               nesting--;
-                       }
-               } while (nesting);
 
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
+       } else {
+               if (IS_UNUSED == IS_UNUSED) {
+                       zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
                }
+               container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
+
 
-               /* We've skipped EXT_FCALL_BEGIND, so also skip the ending opcode */
-               if ((opline + 1)->opcode == ZEND_EXT_FCALL_END) {
-                       opline++;
-               }
-               ZEND_VM_JMP(++opline);
        }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       obj = Z_OBJ_P(object);
-       called_scope = obj->ce;
+static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-       if (IS_VAR != IS_CONST ||
-           EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
-           zend_object *orig_obj = obj;
+       zval *object_ptr;
 
-               if (UNEXPECTED(obj->handlers->get_method == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Object does not support method calls");
-               }
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
 
-               /* First, locate the function. */
-               fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_VAR == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
-               if (UNEXPECTED(fbc == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
-               }
-               if (IS_VAR == IS_CONST &&
-                   EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
-                   EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
-                   EXPECTED(obj == orig_obj)) {
-                       CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope, fbc);
-               }
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
+       ZVAL_DEREF(object_ptr);
+       if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
 
-       if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_STATIC) != 0)) {
-               obj = NULL;
-       } else {
-               GC_REFCOUNT(obj)++; /* For $this pointer */
-       }
+               zval *property_name = NULL;
 
-       EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
-               fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
+               zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_UNUSED == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
 
-       zval_ptr_dtor_nogc(free_op2);
+       } else {
+               zend_free_op free_op_data1;
+               zval  rv;
+               zval *value;
+               zval *dim = NULL;
+               zval *variable_ptr;
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+               if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
+                   EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
+                       zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
 
-static int ZEND_FASTCALL  ZEND_CASE_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
-       zval *result = EX_VAR(opline->result.var);
+                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+                       zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
+                       FREE_OP(free_op_data1);
+               } else {
+                       zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_UNUSED TSRMLS_CC);
 
-       SAVE_OPLINE();
-       fast_equal_function(result,
-                _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-                _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+                       ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+                       variable_ptr = Z_INDIRECT(rv);
+                       if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
+                               FREE_OP(free_op_data1);
+                               if (RETURN_VALUE_USED(opline)) {
+                                       ZVAL_NULL(EX_VAR(opline->result.var));
+                               }
+                       } else {
+                               value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
+                               if ((opline+1)->op1_type == IS_VAR) {
+                                       FREE_OP(free_op_data1);
+                               }
+                               if (RETURN_VALUE_USED(opline)) {
+                                       ZVAL_COPY(EX_VAR(opline->result.var), value);
+                               }
+                       }
+               }
+       }
 
-       zval_ptr_dtor_nogc(free_op2);
+       /* assign_dim has two opcodes! */
        CHECK_EXCEPTION();
+       ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
@@ -39584,9 +33893,9 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_VAR_HANDLER(ZEND_OPCODE
                }
        }
 
-       if (IS_VAR != IS_UNUSED) {
-               zend_free_op free_op2;
-               zval *offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+       if (IS_UNUSED != IS_UNUSED) {
+
+               zval *offset = NULL;
                zend_string *str;
                zend_ulong hval;
 
@@ -39602,7 +33911,7 @@ num_index:
                                break;
                        case IS_STRING:
                                str = Z_STR_P(offset);
-                               if (IS_VAR != IS_CONST) {
+                               if (IS_UNUSED != IS_CONST) {
                                        if (ZEND_HANDLE_NUMERIC(str, hval)) {
                                                goto num_index;
                                        }
@@ -39629,7 +33938,7 @@ str_index:
                                /* do nothing */
                                break;
                }
-               zval_ptr_dtor_nogc(free_op2);
+
        } else {
                zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
        }
@@ -39637,7 +33946,7 @@ str_index:
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        zval *array;
        uint32_t size;
@@ -39663,12 +33972,12 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLE
                ZEND_VM_NEXT_OPCODE();
 #if 0 || IS_CV != IS_UNUSED
        } else {
-               return ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 #endif
        }
 }
 
-static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zval tmp, *varname;
@@ -39677,7 +33986,7 @@ static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER
 
        SAVE_OPLINE();
        if (IS_CV == IS_CV &&
-           IS_VAR == IS_UNUSED &&
+           IS_UNUSED == IS_UNUSED &&
            (opline->extended_value & ZEND_QUICK_SET)) {
                zval *var = EX_VAR(opline->op1.var);
 
@@ -39706,10 +34015,10 @@ static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER
                varname = &tmp;
        }
 
-       if (IS_VAR != IS_UNUSED) {
+       if (IS_UNUSED != IS_UNUSED) {
                zend_class_entry *ce;
 
-               if (IS_VAR == IS_CONST) {
+               if (IS_UNUSED == IS_CONST) {
                        if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
                                ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
                        } else {
@@ -39743,129 +34052,14 @@ static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
-       zval *container;
-       zval *offset;
-       zend_ulong hval;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
-       }
-       if (IS_CV != IS_UNUSED) {
-               ZVAL_DEREF(container);
-       }
-       SEPARATE_ZVAL_NOREF(container);
-       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
-       if (IS_CV != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
-               HashTable *ht = Z_ARRVAL_P(container);
-offset_again:
-               switch (Z_TYPE_P(offset)) {
-                       case IS_DOUBLE:
-                               hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                               zend_hash_index_del(ht, hval);
-                               break;
-                       case IS_LONG:
-                               hval = Z_LVAL_P(offset);
-num_index_dim:
-                               zend_hash_index_del(ht, hval);
-                               break;
-                       case IS_STRING:
-                               if (IS_VAR != IS_CONST) {
-                                       if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
-                                               goto num_index_dim;
-                                       }
-                               }
-                               if (ht == &EG(symbol_table).ht) {
-                                       zend_delete_global_variable(Z_STR_P(offset) TSRMLS_CC);
-                               } else {
-                                       zend_hash_del(ht, Z_STR_P(offset));
-                               }
-                               break;
-                       case IS_NULL:
-                               zend_hash_del(ht, STR_EMPTY_ALLOC());
-                               break;
-                       case IS_FALSE:
-                               hval = 0;
-                               goto num_index_dim;
-                       case IS_TRUE:
-                               hval = 1;
-                               goto num_index_dim;
-                       case IS_RESOURCE:
-                               hval = Z_RES_HANDLE_P(offset);
-                               goto num_index_dim;
-                       case IS_REFERENCE:
-                               offset = Z_REFVAL_P(offset);
-                               goto offset_again;
-                               break;
-                       default:
-                               zend_error(E_WARNING, "Illegal offset type in unset");
-                               break;
-               }
-               zval_ptr_dtor_nogc(free_op2);
-       } else if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use object as array");
-               }
-//???          if (IS_VAR == IS_CONST) {
-//???                  zval_copy_ctor(offset);
-//???          }
-               Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
-               zval_ptr_dtor_nogc(free_op2);
-       } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
-               ZEND_VM_CONTINUE(); /* bailed out before */
-       } else {
-               zval_ptr_dtor_nogc(free_op2);
-       }
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
-       zval *container;
-       zval *offset;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
-       }
-       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
-       if (IS_CV != IS_UNUSED) {
-               ZVAL_DEREF(container);
-       }
-       if (IS_CV == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
-               if (Z_OBJ_HT_P(container)->unset_property) {
-                       Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
-               } else {
-                       zend_error(E_NOTICE, "Trying to unset property of non-object");
-               }
-       }
-       zval_ptr_dtor_nogc(free_op2);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zval *value;
 
        SAVE_OPLINE();
        if (IS_CV == IS_CV &&
-           IS_VAR == IS_UNUSED &&
+           IS_UNUSED == IS_UNUSED &&
            (opline->extended_value & ZEND_QUICK_SET)) {
                value = EX_VAR(opline->op1.var);
                if (opline->extended_value & ZEND_ISSET) {
@@ -39888,10 +34082,10 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE
                        varname = &tmp;
                }
 
-               if (IS_VAR != IS_UNUSED) {
+               if (IS_UNUSED != IS_UNUSED) {
                        zend_class_entry *ce;
 
-                       if (IS_VAR == IS_CONST) {
+                       if (IS_UNUSED == IS_CONST) {
                                if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
                                        ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
                                } else {
@@ -39929,193 +34123,7 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
-       zval *container;
-       int result;
-       zend_ulong hval;
-       zval *offset;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
-       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
-       if (IS_CV != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
-               HashTable *ht = Z_ARRVAL_P(container);
-               zval *value;
-               zend_string *str;
-
-isset_again:
-               if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
-                       str = Z_STR_P(offset);
-                       if (IS_VAR != IS_CONST) {
-                               if (ZEND_HANDLE_NUMERIC(str, hval)) {
-                                       goto num_index_prop;
-                               }
-                       }
-str_index_prop:
-                       value = zend_hash_find_ind(ht, str);
-               } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
-                       hval = Z_LVAL_P(offset);
-num_index_prop:
-                       value = zend_hash_index_find(ht, hval);
-               } else {
-                       switch (Z_TYPE_P(offset)) {
-                               case IS_DOUBLE:
-                                       hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                                       goto num_index_prop;
-                               case IS_NULL:
-                                       str = STR_EMPTY_ALLOC();
-                                       goto str_index_prop;
-                               case IS_FALSE:
-                                       hval = 0;
-                                       goto num_index_prop;
-                               case IS_TRUE:
-                                       hval = 1;
-                                       goto num_index_prop;
-                               case IS_RESOURCE:
-                                       hval = Z_RES_HANDLE_P(offset);
-                                       goto num_index_prop;
-                               case IS_REFERENCE:
-                                       offset = Z_REFVAL_P(offset);
-                                       goto isset_again;
-                               default:
-                                       zend_error(E_WARNING, "Illegal offset type in isset or empty");
-                                       value = NULL;
-                                       break;
-                       }
-               }
-
-               if (opline->extended_value & ZEND_ISSET) {
-                       /* > IS_NULL means not IS_UNDEF and not IS_NULL */
-                       result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
-               }
-       } else if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
-                       result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
-               } else {
-                       zend_error(E_NOTICE, "Trying to check element of non-array");
-                       result = 0;
-               }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
-               }
-       } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
-               zval tmp;
-
-               result = 0;
-               if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
-                       if (IS_VAR == IS_CV || IS_VAR == IS_VAR) {
-                               ZVAL_DEREF(offset);
-                       }
-                       if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
-                                       || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
-                                               && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
-                               ZVAL_DUP(&tmp, offset);
-                               convert_to_long(&tmp);
-                               offset = &tmp;
-                       }
-               }
-               if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
-                       if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
-                               if ((opline->extended_value & ZEND_ISSET) ||
-                                   Z_STRVAL_P(container)[offset->value.lval] != '0') {
-                                       result = 1;
-                               }
-                       }
-               }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
-               }
-       } else {
-               result = ((opline->extended_value & ZEND_ISSET) == 0);
-       }
-
-       zval_ptr_dtor_nogc(free_op2);
-       ZVAL_BOOL(EX_VAR(opline->result.var), result);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
-       zval *container;
-       int result;
-       zval *offset;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
-       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
-
-       if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
-                       result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_VAR == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
-               } else {
-                       zend_error(E_NOTICE, "Trying to check property of non-object");
-                       result = 0;
-               }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
-               }
-       } else {
-               result = ((opline->extended_value & ZEND_ISSET) == 0);
-       }
-
-       zval_ptr_dtor_nogc(free_op2);
-       ZVAL_BOOL(EX_VAR(opline->result.var), result);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_INSTANCEOF_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       zval *expr;
-       zend_bool result;
-
-       SAVE_OPLINE();
-       expr = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-
-       if (Z_TYPE_P(expr) == IS_OBJECT) {
-               zend_class_entry *ce;
-
-               if (IS_VAR == IS_CONST) {
-                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                       } else {
-                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, ZEND_FETCH_CLASS_NO_AUTOLOAD TSRMLS_CC);
-                               if (UNEXPECTED(ce == NULL)) {
-                                       ZVAL_FALSE(EX_VAR(opline->result.var));
-
-                                       CHECK_EXCEPTION();
-                                       ZEND_VM_NEXT_OPCODE();
-                               }
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
-                       }
-               } else {
-                       ce = Z_CE_P(EX_VAR(opline->op2.var));
-               }
-               result = instanceof_function(Z_OBJCE_P(expr), ce TSRMLS_CC);
-       } else {
-               result = 0;
-       }
-       ZVAL_BOOL(EX_VAR(opline->result.var), result);
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_YIELD_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_YIELD_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
@@ -40196,21 +34204,21 @@ static int ZEND_FASTCALL  ZEND_YIELD_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
        }
 
        /* Set the new yielded key */
-       if (IS_VAR != IS_UNUSED) {
-               zend_free_op free_op2;
-               zval *key = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+       if (IS_UNUSED != IS_UNUSED) {
+
+               zval *key = NULL;
 
                /* Consts, temporary variables and references need copying */
-               if (IS_VAR == IS_CONST) {
+               if (IS_UNUSED == IS_CONST) {
                        ZVAL_DUP(&generator->key, key);
-               } else if (IS_VAR == IS_TMP_VAR) {
+               } else if (IS_UNUSED == IS_TMP_VAR) {
                        ZVAL_COPY_VALUE(&generator->key, key);
-               } else if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && Z_ISREF_P(key)) {
+               } else if ((IS_UNUSED == IS_VAR || IS_UNUSED == IS_CV) && Z_ISREF_P(key)) {
                        ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
-                       zval_ptr_dtor_nogc(free_op2);
+
                } else {
                        ZVAL_COPY_VALUE(&generator->key, key);
-                       if (IS_VAR == IS_CV) {
+                       if (IS_UNUSED == IS_CV) {
                                if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
                        }
                }
@@ -40246,32 +34254,292 @@ static int ZEND_FASTCALL  ZEND_YIELD_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
        ZEND_VM_RETURN();
 }
 
-static int ZEND_FASTCALL  ZEND_POW_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_POW_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_binary_assign_op_helper_SPEC_CV_UNUSED(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL  ZEND_ADD_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
+
 
        SAVE_OPLINE();
-       pow_function(EX_VAR(opline->result.var),
+       fast_add_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_SUB_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+
+       SAVE_OPLINE();
+       fast_sub_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_MUL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+
+       SAVE_OPLINE();
+       fast_mul_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_DIV_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+
+       SAVE_OPLINE();
+       fast_div_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_MOD_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+
+       SAVE_OPLINE();
+       fast_mod_function(EX_VAR(opline->result.var),
                _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_var_deref(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
 
-       zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_POW_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_binary_assign_op_helper_SPEC_CV_VAR(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       USE_OPLINE
+
+
+       SAVE_OPLINE();
+       shift_left_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+
+       SAVE_OPLINE();
+       shift_right_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+
+       SAVE_OPLINE();
+       concat_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+
+       SAVE_OPLINE();
+       fast_is_identical_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       zval *result = EX_VAR(opline->result.var);
+
+       SAVE_OPLINE();
+       fast_is_not_identical_function(result,
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       zval *result = EX_VAR(opline->result.var);
+
+       SAVE_OPLINE();
+       fast_equal_function(result,
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       zval *result = EX_VAR(opline->result.var);
+
+       SAVE_OPLINE();
+       fast_not_equal_function(result,
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       zval *result = EX_VAR(opline->result.var);
+
+       SAVE_OPLINE();
+       fast_is_smaller_function(result,
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       zval *result = EX_VAR(opline->result.var);
+
+       SAVE_OPLINE();
+       fast_is_smaller_or_equal_function(result,
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+
+       SAVE_OPLINE();
+       bitwise_or_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+
+       SAVE_OPLINE();
+       bitwise_and_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+
+       SAVE_OPLINE();
+       bitwise_xor_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+
+       SAVE_OPLINE();
+       boolean_xor_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_CV(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op_data1;
        zval *object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
-       zval *property = NULL;
+       zval *property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
        zval *value;
        zval *zptr;
 
@@ -40297,7 +34565,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(int (*b
                /* here we are sure we are dealing with an object */
                if (opline->extended_value == ZEND_ASSIGN_OBJ
                        && EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-                       && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_UNUSED == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+                       && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
 
                        ZVAL_DEREF(zptr);
                        SEPARATE_ZVAL_NOREF(zptr);
@@ -40312,7 +34580,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(int (*b
 
                        if (opline->extended_value == ZEND_ASSIGN_OBJ) {
                                if (Z_OBJ_HT_P(object)->read_property) {
-                                       z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_UNUSED == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+                                       z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
                                }
                        } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
                                if (Z_OBJ_HT_P(object)->read_dimension) {
@@ -40333,7 +34601,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(int (*b
                                SEPARATE_ZVAL_IF_NOT_REF(z);
                                binary_op(z, z, value TSRMLS_CC);
                                if (opline->extended_value == ZEND_ASSIGN_OBJ) {
-                                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_UNUSED == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+                                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
                                } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
                                        Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
                                }
@@ -40358,7 +34626,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(int (*b
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_CV_CV(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op_data1;
@@ -40377,11 +34645,11 @@ static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(int (*b
                if (IS_CV == IS_VAR && !0) {
                        Z_ADDREF_P(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
                }
-               return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_CV_CV(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else {
-               zval *dim = NULL;
+               zval *dim = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
 
-               zend_fetch_dimension_address_RW(&rv, container, dim, IS_UNUSED TSRMLS_CC);
+               zend_fetch_dimension_address_RW(&rv, container, dim, IS_CV TSRMLS_CC);
                value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
                ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
                var_ptr = Z_INDIRECT(rv);
@@ -40413,7 +34681,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(int (*b
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_UNUSED(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_CV(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
@@ -40421,7 +34689,7 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_UNUSED(int (*binar
        zval *value;
 
        SAVE_OPLINE();
-       value = NULL;
+       value = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
        var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
 
        if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
@@ -40448,298 +34716,339 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_UNUSED(int (*binar
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_ADD_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_ADD_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_UNUSED(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_CV_CV(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_CV_CV(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_CV_CV(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SUB_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_SUB_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_UNUSED(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_CV_CV(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_CV_CV(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_CV_CV(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_MUL_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_MUL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_UNUSED(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_CV_CV(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_CV_CV(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_CV_CV(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_DIV_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_DIV_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_UNUSED(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_CV_CV(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_CV_CV(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_CV_CV(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_MOD_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_MOD_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_UNUSED(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_helper_SPEC_CV_CV(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_dim_helper_SPEC_CV_CV(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_binary_assign_op_obj_helper_SPEC_CV_CV(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
+
+static int ZEND_FASTCALL  ZEND_ASSIGN_SL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_CV(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_CV(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_CV(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
+
+static int ZEND_FASTCALL  ZEND_ASSIGN_SR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_CV(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_CV(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_CV(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
+
+static int ZEND_FASTCALL  ZEND_ASSIGN_CONCAT_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_CV(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_CV(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_CV(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
+
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_OR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_CV(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_CV(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_CV(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
+
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_AND_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_CV(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_CV(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_CV(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
+
+static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       if (EXPECTED(opline->extended_value == 0)) {
+               return zend_binary_assign_op_helper_SPEC_CV_CV(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
+               return zend_binary_assign_op_dim_helper_SPEC_CV_CV(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
+               return zend_binary_assign_op_obj_helper_SPEC_CV_CV(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
+
+static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_CV(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       zval *object;
+       zval *property;
+       zval *retval;
+       zval *zptr;
+
+       SAVE_OPLINE();
+       object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+       property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+       retval = EX_VAR(opline->result.var);
+
+       if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
+       }
+
+       if (IS_CV != IS_UNUSED) {
+               object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
+       }
+
+       if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+               zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_NULL(retval);
+               }
+
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
+       }
+
+       /* here we are sure we are dealing with an object */
+
+       if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+
+               ZVAL_DEREF(zptr);
+               SEPARATE_ZVAL_NOREF(zptr);
+
+               incdec_op(zptr);
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_COPY(retval, zptr);
+               }
+       } else {
+               zval rv;
+
+               if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
+                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
+                               zval rv;
+                               zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+
+                               if (Z_REFCOUNT_P(z) == 0) {
+                                       zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
+                               }
+                               ZVAL_COPY_VALUE(z, value);
+                       }
+                       if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
+                       SEPARATE_ZVAL_IF_NOT_REF(z);
+                       incdec_op(z);
+                       ZVAL_COPY_VALUE(retval, z);
+                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+                       SELECTIVE_PZVAL_LOCK(retval, opline);
+                       zval_ptr_dtor(z);
+               } else {
+                       zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+                       if (RETURN_VALUE_USED(opline)) {
+                               ZVAL_NULL(retval);
+                       }
+               }
        }
-}
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SL_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_UNUSED(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SR_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_PRE_INC_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_UNUSED(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
+       return zend_pre_incdec_property_helper_SPEC_CV_CV(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_CONCAT_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_UNUSED(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
+       return zend_pre_incdec_property_helper_SPEC_CV_CV(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_OR_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CV(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_UNUSED(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
+       zval *object;
+       zval *property;
+       zval *retval;
+       zval *zptr;
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_AND_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       SAVE_OPLINE();
+       object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
+       property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+       retval = EX_VAR(opline->result.var);
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_UNUSED(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_UNUSED(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_UNUSED(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       if (IS_CV != IS_UNUSED) {
+               object = make_real_object(object TSRMLS_CC); /* this should modify object only if it's empty */
        }
-}
 
-static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CV_UNUSED(int type, ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       zval *varname;
-       zval *retval;
-       zend_string *name;
-       HashTable *target_symbol_table;
+       if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+               zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
 
-       SAVE_OPLINE();
-       varname = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+               ZVAL_NULL(retval);
 
-       if (IS_CV == IS_CONST) {
-               name = Z_STR_P(varname);
-       } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
-               name = Z_STR_P(varname);
-               zend_string_addref(name);
-       } else {
-               name = zval_get_string(varname);
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
        }
 
-       if (IS_UNUSED != IS_UNUSED) {
-               zend_class_entry *ce;
+       /* here we are sure we are dealing with an object */
 
-               if (IS_UNUSED == IS_CONST) {
-                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                       } else {
-                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                               if (UNEXPECTED(ce == NULL)) {
-                                       if (IS_CV != IS_CONST) {
-                                               zend_string_release(name);
-                                       }
+       if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
+               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
 
-                                       CHECK_EXCEPTION();
-                                       ZEND_VM_NEXT_OPCODE();
-                               }
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
-                       }
-               } else {
-                       ce = Z_CE_P(EX_VAR(opline->op2.var));
-               }
-               retval = zend_std_get_static_property(ce, name, 0, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+               ZVAL_DEREF(zptr);
+               ZVAL_COPY_VALUE(retval, zptr);
+               zval_opt_copy_ctor(zptr);
 
+               incdec_op(zptr);
        } else {
-               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-               retval = zend_hash_find(target_symbol_table, name);
-               if (retval == NULL) {
-                       switch (type) {
-                               case BP_VAR_R:
-                               case BP_VAR_UNSET:
-                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                       /* break missing intentionally */
-                               case BP_VAR_IS:
-                                       retval = &EG(uninitialized_zval);
-                                       break;
-                               case BP_VAR_RW:
-                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                       /* break missing intentionally */
-                               case BP_VAR_W:
-                                       retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
-                                       break;
-                               EMPTY_SWITCH_DEFAULT_CASE()
-                       }
-               /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
-               } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
-                       retval = Z_INDIRECT_P(retval);
-                       if (Z_TYPE_P(retval) == IS_UNDEF) {
-                               switch (type) {
-                                       case BP_VAR_R:
-                                       case BP_VAR_UNSET:
-                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                               /* break missing intentionally */
-                                       case BP_VAR_IS:
-                                               retval = &EG(uninitialized_zval);
-                                               break;
-                                       case BP_VAR_RW:
-                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
-                                               /* break missing intentionally */
-                                       case BP_VAR_W:
-                                               ZVAL_NULL(retval);
-                                               break;
-                                       EMPTY_SWITCH_DEFAULT_CASE()
+               if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
+                       zval rv;
+                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+                       zval z_copy;
+
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
+                               zval rv;
+                               zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+
+                               if (Z_REFCOUNT_P(z) == 0) {
+                                       zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
                                }
+                               ZVAL_COPY_VALUE(z, value);
                        }
-               }
-               if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
-                       if (Z_CONSTANT_P(retval)) {
-                               zval_update_constant(retval, 1 TSRMLS_CC);
-                       }
-               } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
-
+                       ZVAL_DUP(retval, z);
+                       ZVAL_DUP(&z_copy, z);
+                       incdec_op(&z_copy);
+                       if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
+                       Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+                       zval_ptr_dtor(&z_copy);
+                       zval_ptr_dtor(z);
+               } else {
+                       zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
+                       ZVAL_NULL(retval);
                }
        }
 
-       if (IS_CV != IS_CONST) {
-               zend_string_release(name);
-       }
 
-       ZEND_ASSERT(retval != NULL);
-       if (type == BP_VAR_R || type == BP_VAR_IS) {
-               if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
-                       ZVAL_UNREF(retval);
-               }
-               ZVAL_COPY(EX_VAR(opline->result.var), retval);
-       } else {
-               ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
-       }
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_R_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_W_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_POST_INC_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_post_incdec_property_helper_SPEC_CV_CV(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_RW_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_post_incdec_property_helper_SPEC_CV_CV(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_FUNC_ARG_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-               return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else {
-               return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
+       zval *container;
 
-static int ZEND_FASTCALL  ZEND_FETCH_UNSET_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
+       SAVE_OPLINE();
+       container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+       zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
 
-static int ZEND_FASTCALL  ZEND_FETCH_IS_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_var_address_helper_SPEC_CV_UNUSED(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
@@ -40752,7 +35061,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HA
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
        ZVAL_DEREF(container);
-       zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
+       zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
 
        if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
                EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
@@ -40762,7 +35071,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HA
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
@@ -40775,7 +35084,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_H
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
        ZVAL_DEREF(container);
-       zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
+       zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
 
        if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
                EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
@@ -40785,7 +35094,22 @@ static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_H
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       zval *container;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
+       zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
+
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zval *container;
@@ -40802,18 +35126,18 @@ static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_UNUSED_HANDLER(ZEND_OP
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
                ZVAL_DEREF(container);
-               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
+               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
                if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
                        EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
                }
 
 
        } else {
-               if (IS_UNUSED == IS_UNUSED) {
+               if (IS_CV == IS_UNUSED) {
                        zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
                }
                container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, NULL, IS_UNUSED TSRMLS_CC);
+               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
 
 
        }
@@ -40821,1073 +35145,1200 @@ static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_UNUSED_HANDLER(ZEND_OP
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_DIM_UNSET_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
-       zval *object_ptr;
+       zend_free_op free_op1;
+       zval *container;
 
        SAVE_OPLINE();
-       object_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+       container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       ZVAL_DEREF(object_ptr);
-       if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
-
-               zval *property_name = NULL;
-
-               zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_UNUSED == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
-
-       } else {
-               zend_free_op free_op_data1;
-               zval  rv;
-               zval *value;
-               zval *dim = NULL;
-               zval *variable_ptr;
-
-               if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
-                   EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
-                       zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
-
-                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-                       zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
-                       FREE_OP(free_op_data1);
-               } else {
-                       zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_UNUSED TSRMLS_CC);
+       ZVAL_DEREF(container);
+       zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
 
-                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-                       ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
-                       variable_ptr = Z_INDIRECT(rv);
-                       if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
-                               FREE_OP(free_op_data1);
-                               if (RETURN_VALUE_USED(opline)) {
-                                       ZVAL_NULL(EX_VAR(opline->result.var));
-                               }
-                       } else {
-                               value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
-                               if ((opline+1)->op1_type == IS_VAR) {
-                                       FREE_OP(free_op_data1);
-                               }
-                               if (RETURN_VALUE_USED(opline)) {
-                                       ZVAL_COPY(EX_VAR(opline->result.var), value);
-                               }
-                       }
-               }
+       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
 
-       /* assign_dim has two opcodes! */
        CHECK_EXCEPTION();
-       ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *expr_ptr, new_expr;
+       zval *container;
+
+       zval *offset;
 
        SAVE_OPLINE();
-       if ((IS_CV == IS_VAR || IS_CV == IS_CV) &&
-           (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
-               expr_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-               if (IS_CV == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
-               }
-               ZVAL_MAKE_REF(expr_ptr);
-               Z_ADDREF_P(expr_ptr);
+       container = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+       offset  = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
 
+       if ((IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               zend_error(E_NOTICE, "Trying to get property of non-object");
+               ZVAL_NULL(EX_VAR(opline->result.var));
        } else {
-               expr_ptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-               if (IS_CV == IS_TMP_VAR) {
-                       ZVAL_COPY_VALUE(&new_expr, expr_ptr);
-                       expr_ptr = &new_expr;
-               } else if (IS_CV == IS_CONST) {
-                       if (!Z_IMMUTABLE_P(expr_ptr)) {
-                               ZVAL_DUP(&new_expr, expr_ptr);
-                               expr_ptr = &new_expr;
-                       }
-               } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(expr_ptr)) {
-                       expr_ptr = Z_REFVAL_P(expr_ptr);
-                       if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
-
-               } else if (IS_CV == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
-                       Z_ADDREF_P(expr_ptr);
-               }
-       }
-
-       if (IS_UNUSED != IS_UNUSED) {
+               zval *retval;
 
-               zval *offset = NULL;
-               zend_string *str;
-               zend_ulong hval;
+               /* here we are sure we are dealing with an object */
+               do {
+                       if (IS_CV == IS_CONST &&
+                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
+                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
+                               zend_object *zobj = Z_OBJ_P(container);
 
-add_again:
-               switch (Z_TYPE_P(offset)) {
-                       case IS_DOUBLE:
-                               hval = zend_dval_to_lval(Z_DVAL_P(offset));
-                               goto num_index;
-                       case IS_LONG:
-                               hval = Z_LVAL_P(offset);
-num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
-                               break;
-                       case IS_STRING:
-                               str = Z_STR_P(offset);
-                               if (IS_UNUSED != IS_CONST) {
-                                       if (ZEND_HANDLE_NUMERIC(str, hval)) {
-                                               goto num_index;
+                               if (EXPECTED(prop_info)) {
+                                       retval = OBJ_PROP(zobj, prop_info->offset);
+                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
+                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                                               break;
                                        }
-                               }
-str_index:
-                               zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
-                               break;
-                       case IS_NULL:
-                               str = STR_EMPTY_ALLOC();
-                               goto str_index;
-                       case IS_FALSE:
-                               hval = 0;
-                               goto num_index;
-                       case IS_TRUE:
-                               hval = 1;
-                               goto num_index;
-                       case IS_REFERENCE:
-                               offset = Z_REFVAL_P(offset);
-                               goto add_again;
-                               break;
-                       default:
-                               zend_error(E_WARNING, "Illegal offset type");
-                               zval_ptr_dtor(expr_ptr);
-                               /* do nothing */
-                               break;
-               }
-
-       } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
-       }
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       zval *array;
-       uint32_t size;
-       USE_OPLINE
-
-       array = EX_VAR(opline->result.var);
-       if (IS_CV != IS_UNUSED) {
-               size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
-       } else {
-               size = 0;
-       }
-       ZVAL_NEW_ARR(array);
-       zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
-
-       if (IS_CV != IS_UNUSED) {
-               /* Explicitly initialize array as not-packed if flag is set */
-               if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
-                       zend_hash_real_init(Z_ARRVAL_P(array), 0);
-               }
-       }
-
-       if (IS_CV == IS_UNUSED) {
-               ZEND_VM_NEXT_OPCODE();
-#if 0 || IS_CV != IS_UNUSED
-       } else {
-               return ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-#endif
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zval tmp, *varname;
-       HashTable *target_symbol_table;
-
-
-       SAVE_OPLINE();
-       if (IS_CV == IS_CV &&
-           IS_UNUSED == IS_UNUSED &&
-           (opline->extended_value & ZEND_QUICK_SET)) {
-               zval *var = EX_VAR(opline->op1.var);
-
-               if (Z_REFCOUNTED_P(var)) {
-                       zend_refcounted *garbage = Z_COUNTED_P(var);
-
-                       if (!--GC_REFCOUNT(garbage)) {
-                               ZVAL_UNDEF(var);
-                               _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
-                       } else {
-                               GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
-                               ZVAL_UNDEF(var);
-                       }
-               } else {
-                       ZVAL_UNDEF(var);
-               }
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
-       }
-
-       varname = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-
-       ZVAL_UNDEF(&tmp);
-       if (IS_CV != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-               ZVAL_STR(&tmp, zval_get_string(varname));
-               varname = &tmp;
-       }
-
-       if (IS_UNUSED != IS_UNUSED) {
-               zend_class_entry *ce;
-
-               if (IS_UNUSED == IS_CONST) {
-                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                       } else {
-                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                               if (UNEXPECTED(EG(exception) != NULL)) {
-                                       if (IS_CV != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-                                               zend_string_release(Z_STR(tmp));
+                               } else if (EXPECTED(zobj->properties != NULL)) {
+                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
+                                       if (EXPECTED(retval)) {
+                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                                               break;
                                        }
-
-                                       HANDLE_EXCEPTION();
-                               }
-                               if (UNEXPECTED(ce == NULL)) {
-                                       zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
                                }
-                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
                        }
-               } else {
-                       ce = Z_CE_P(EX_VAR(opline->op2.var));
-               }
-               zend_std_unset_static_property(ce, Z_STR_P(varname), ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
-       } else {
-               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-               zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
-       }
 
-       if (IS_CV != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-               zend_string_release(Z_STR(tmp));
+                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+
+                       if (retval != EX_VAR(opline->result.var)) {
+                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                       }
+               } while (0);
        }
 
+
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zval *value;
+       zend_free_op free_op1;
+       zval *property;
+       zval *container;
 
        SAVE_OPLINE();
-       if (IS_CV == IS_CV &&
-           IS_UNUSED == IS_UNUSED &&
-           (opline->extended_value & ZEND_QUICK_SET)) {
-               value = EX_VAR(opline->op1.var);
-               if (opline->extended_value & ZEND_ISSET) {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               !i_zend_is_true(value TSRMLS_CC));
-                       CHECK_EXCEPTION();
-               }
-               ZEND_VM_NEXT_OPCODE();
-       } else {
-
-               zval tmp, *varname = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
-
-               ZVAL_UNDEF(&tmp);
-               if (IS_CV != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-                       ZVAL_STR(&tmp, zval_get_string(varname));
-                       varname = &tmp;
-               }
-
-               if (IS_UNUSED != IS_UNUSED) {
-                       zend_class_entry *ce;
-
-                       if (IS_UNUSED == IS_CONST) {
-                               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
-                                       ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
-                               } else {
-                                       ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
-                                       if (UNEXPECTED(ce == NULL)) {
-                                               CHECK_EXCEPTION();
-                                               ZEND_VM_NEXT_OPCODE();
-                                       }
-                                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
-                               }
-                       } else {
-                               ce = Z_CE_P(EX_VAR(opline->op2.var));
-                       }
-                       value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
-               } else {
-                       HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-                       value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
-               }
+       property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
 
-               if (IS_CV != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
-                       zend_string_release(Z_STR(tmp));
-               }
+       container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+       }
 
-               if (opline->extended_value & ZEND_ISSET) {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               value && Z_TYPE_P(value) > IS_NULL &&
-                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
-               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
-                       ZVAL_BOOL(EX_VAR(opline->result.var),
-                               !value || !i_zend_is_true(value TSRMLS_CC));
-               }
+       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CV, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
 
-               CHECK_EXCEPTION();
-               ZEND_VM_NEXT_OPCODE();
+       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_YIELD_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zend_free_op free_op1;
+       zval *property;
+       zval *container;
 
-       /* The generator object is stored in EX(return_value) */
-       zend_generator *generator = (zend_generator *) EX(return_value);
+       SAVE_OPLINE();
+       property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+       container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
 
-       if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
-               zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
+       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CV, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
 
-       /* Destroy the previously yielded value */
-       zval_ptr_dtor(&generator->value);
-
-       /* Destroy the previously yielded key */
-       zval_ptr_dtor(&generator->key);
+       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+       }
 
-       /* Set the new yielded value */
-       if (IS_CV != IS_UNUSED) {
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
 
-               if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
-                       /* Constants and temporary variables aren't yieldable by reference,
-                        * but we still allow them with a notice. */
-                       if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
-                               zval *value;
+       zval *container;
 
-                               zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+       zval *offset;
 
-                               value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-                               ZVAL_COPY_VALUE(&generator->value, value);
-                               if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
+       SAVE_OPLINE();
+       container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
+       offset  = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
 
-                               /* Temporary variables don't need ctor copying */
-                               if (IS_CV != IS_TMP_VAR) {
-                                       zval_opt_copy_ctor(&generator->value);
-                               }
-                       } else {
-                               zval *value_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+       if ((IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               ZVAL_NULL(EX_VAR(opline->result.var));
+       } else {
+               zval *retval;
 
-                               if (IS_CV == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
-                                       zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
-                               }
+               /* here we are sure we are dealing with an object */
+               do {
+                       if (IS_CV == IS_CONST &&
+                               EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
+                               zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
+                               zend_object *zobj = Z_OBJ_P(container);
 
-                               /* If a function call result is yielded and the function did
-                                * not return by reference we throw a notice. */
-                               if (IS_CV == IS_VAR &&
-                                   (value_ptr == &EG(uninitialized_zval) ||
-                                    (opline->extended_value == ZEND_RETURNS_FUNCTION &&
-                                     !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
-                                       zend_error(E_NOTICE, "Only variable references should be yielded by reference");
-                               } else {
-                                       ZVAL_MAKE_REF(value_ptr);
+                               if (EXPECTED(prop_info)) {
+                                       retval = OBJ_PROP(zobj, prop_info->offset);
+                                       if (EXPECTED(Z_TYPE_P(retval) != IS_UNDEF)) {
+                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                                               break;
+                                       }
+                               } else if (EXPECTED(zobj->properties != NULL)) {
+                                       retval = zend_hash_find(zobj->properties, Z_STR_P(offset));
+                                       if (EXPECTED(retval)) {
+                                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+                                               break;
+                                       }
                                }
-                               ZVAL_COPY(&generator->value, value_ptr);
-
                        }
-               } else {
-                       zval *value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
 
-                       /* Consts, temporary variables and references need copying */
-                       if (IS_CV == IS_CONST) {
-                               ZVAL_DUP(&generator->value, value);
-                       } else if (IS_CV == IS_TMP_VAR) {
-                               ZVAL_COPY_VALUE(&generator->value, value);
-            } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(value)) {
-                               ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
+                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
 
-                       } else {
-                               ZVAL_COPY_VALUE(&generator->value, value);
-                               if (IS_CV == IS_CV) {
-                                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
-                               }
+                       if (retval != EX_VAR(opline->result.var)) {
+                               ZVAL_COPY(EX_VAR(opline->result.var), retval);
                        }
-               }
-       } else {
-               /* If no value was specified yield null */
-               ZVAL_NULL(&generator->value);
+               } while (0);
        }
 
-       /* Set the new yielded key */
-       if (IS_UNUSED != IS_UNUSED) {
 
-               zval *key = NULL;
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-               /* Consts, temporary variables and references need copying */
-               if (IS_UNUSED == IS_CONST) {
-                       ZVAL_DUP(&generator->key, key);
-               } else if (IS_UNUSED == IS_TMP_VAR) {
-                       ZVAL_COPY_VALUE(&generator->key, key);
-               } else if ((IS_UNUSED == IS_VAR || IS_UNUSED == IS_CV) && Z_ISREF_P(key)) {
-                       ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zval *container;
 
-               } else {
-                       ZVAL_COPY_VALUE(&generator->key, key);
-                       if (IS_UNUSED == IS_CV) {
-                               if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
-                       }
+       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+               /* Behave like FETCH_OBJ_W */
+               zend_free_op free_op1;
+               zval *property;
+
+               SAVE_OPLINE();
+               property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+               container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+
+        if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
+            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
+        }
+               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
                }
+               zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CV, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
 
-               if (Z_TYPE(generator->key) == IS_LONG
-                   && Z_LVAL(generator->key) > generator->largest_used_integer_key
-               ) {
-                       generator->largest_used_integer_key = Z_LVAL(generator->key);
+               if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
                }
-       } else {
-               /* If no key was specified we use auto-increment keys */
-               generator->largest_used_integer_key++;
-               ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
-       }
 
-       if (RETURN_VALUE_USED(opline)) {
-               /* If the return value of yield is used set the send
-                * target and initialize it to NULL */
-               generator->send_target = EX_VAR(opline->result.var);
-               ZVAL_NULL(generator->send_target);
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
        } else {
-               generator->send_target = NULL;
+               return ZEND_FETCH_OBJ_R_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
-
-       /* We increment to the next op, so we are at the correct position when the
-        * generator is resumed. */
-       ZEND_VM_INC_OPCODE();
-
-       /* The GOTO VM uses a local opline variable. We need to set the opline
-        * variable in execute_data so we don't resume at an old position. */
-       SAVE_OPLINE();
-
-       ZEND_VM_RETURN();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_POW_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_binary_assign_op_helper_SPEC_CV_UNUSED(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_ADD_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
+       zend_free_op free_op1;
+       zval *container, *property;
 
        SAVE_OPLINE();
-       fast_add_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+       container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
+       property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+       }
+       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CV, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
 
+       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
+               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
+       }
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_SUB_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
+       zval *object;
+       zval *property_name;
 
        SAVE_OPLINE();
-       fast_sub_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+       object = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+       property_name = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
 
+       if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+       }
+       zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
 
+
+       /* assign_obj has two opcodes! */
        CHECK_EXCEPTION();
+       ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_MUL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
+       zval *object_ptr;
 
        SAVE_OPLINE();
-       fast_mul_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+       object_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
 
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
+       }
+       ZVAL_DEREF(object_ptr);
+       if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+               zval *property_name = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
 
-static int ZEND_FASTCALL  ZEND_DIV_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+               zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
 
+       } else {
+               zend_free_op free_op_data1;
+               zval  rv;
+               zval *value;
+               zval *dim = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+               zval *variable_ptr;
 
-       SAVE_OPLINE();
-       fast_div_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+               if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
+                   EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
+                       zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
 
+                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+                       zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
+                       FREE_OP(free_op_data1);
+               } else {
+                       zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_CV TSRMLS_CC);
+
+                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+                       ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
+                       variable_ptr = Z_INDIRECT(rv);
+                       if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
+                               FREE_OP(free_op_data1);
+                               if (RETURN_VALUE_USED(opline)) {
+                                       ZVAL_NULL(EX_VAR(opline->result.var));
+                               }
+                       } else {
+                               value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
+                               if ((opline+1)->op1_type == IS_VAR) {
+                                       FREE_OP(free_op_data1);
+                               }
+                               if (RETURN_VALUE_USED(opline)) {
+                                       ZVAL_COPY(EX_VAR(opline->result.var), value);
+                               }
+                       }
+               }
+       }
 
+       /* assign_dim has two opcodes! */
        CHECK_EXCEPTION();
+       ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_MOD_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
+       zval *value;
+       zval *variable_ptr;
 
        SAVE_OPLINE();
-       fast_mod_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+       value = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+       variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
+               if (IS_CV == IS_TMP_VAR) {
+
+               }
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
+       } else {
+               value = zend_assign_to_variable(variable_ptr, value, IS_CV TSRMLS_CC);
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_COPY(EX_VAR(opline->result.var), value);
+               }
+
+       }
 
+       /* zend_assign_to_variable() always takes care of op2, never free it! */
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_SL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_REF_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
+       zval *variable_ptr;
+       zval *value_ptr;
 
        SAVE_OPLINE();
-       shift_left_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+       value_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op2.var TSRMLS_CC);
+
+       if (IS_CV == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
+       }
+       if (IS_CV == IS_VAR &&
+           (value_ptr == &EG(uninitialized_zval) ||
+            (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+             !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+               if (!0) {
+                       PZVAL_LOCK(value_ptr); /* undo the effect of get_zval_ptr_ptr() */
+               }
+               zend_error(E_STRICT, "Only variables should be assigned by reference");
+               if (UNEXPECTED(EG(exception) != NULL)) {
+
+                       HANDLE_EXCEPTION();
+               }
+               return ZEND_ASSIGN_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else if (IS_CV == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
+               if (!0) {
+                       PZVAL_LOCK(value_ptr);
+               }
+       }
+
+       variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+       if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
+       }
+       if (IS_CV == IS_VAR &&
+           UNEXPECTED(Z_TYPE_P(EX_VAR(opline->op1.var)) != IS_INDIRECT) &&
+           UNEXPECTED(!Z_ISREF_P(variable_ptr))) {
+               zend_error_noreturn(E_ERROR, "Cannot assign by reference to overloaded object");
+       }
+       if ((IS_CV == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) ||
+           (IS_CV == IS_VAR && UNEXPECTED(value_ptr == &EG(error_zval)))) {
+               variable_ptr = &EG(uninitialized_zval);
+       } else {
+               zend_assign_to_variable_reference(variable_ptr, value_ptr TSRMLS_CC);
+       }
+
+       if (IS_CV == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
+               if (!0) {
+                       Z_DELREF_P(variable_ptr);
+               }
+       }
+
+       if (RETURN_VALUE_USED(opline)) {
+               ZVAL_COPY(EX_VAR(opline->result.var), variable_ptr);
+       }
 
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_SR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zval *function_name;
 
+       zval *object;
+       zend_function *fbc;
+       zend_class_entry *called_scope;
+       zend_object *obj;
 
        SAVE_OPLINE();
-       shift_right_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
+       function_name = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+       if (IS_CV != IS_CONST &&
+           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
+               if (UNEXPECTED(EG(exception) != NULL)) {
+                       HANDLE_EXCEPTION();
+               }
+               zend_error_noreturn(E_ERROR, "Method name must be a string");
+       }
+
+       object = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+
+       if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
+               uint32_t nesting = 1;
+
+               if (UNEXPECTED(EG(exception) != NULL)) {
+
+                       HANDLE_EXCEPTION();
+               }
+
+               zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s",  Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
+
+
+               if (EG(exception) != NULL) {
+                       HANDLE_EXCEPTION();
+               }
+
+               /* No exception raised: Skip over arguments until fcall opcode with correct
+                * nesting level. Return NULL (except when return value unused) */
+               do {
+                       opline++;
+                       if (opline->opcode == ZEND_INIT_FCALL ||
+                               opline->opcode == ZEND_INIT_FCALL_BY_NAME ||
+                               opline->opcode == ZEND_INIT_NS_FCALL_BY_NAME ||
+                               opline->opcode == ZEND_INIT_METHOD_CALL ||
+                               opline->opcode == ZEND_INIT_STATIC_METHOD_CALL ||
+                               opline->opcode == ZEND_INIT_USER_CALL ||
+                               opline->opcode == ZEND_NEW
+                       ) {
+                               nesting++;
+                       } else if (opline->opcode == ZEND_DO_FCALL) {
+                               nesting--;
+                       }
+               } while (nesting);
 
-static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+               if (RETURN_VALUE_USED(opline)) {
+                       ZVAL_NULL(EX_VAR(opline->result.var));
+               }
 
+               /* We've skipped EXT_FCALL_BEGIND, so also skip the ending opcode */
+               if ((opline + 1)->opcode == ZEND_EXT_FCALL_END) {
+                       opline++;
+               }
+               ZEND_VM_JMP(++opline);
+       }
 
-       SAVE_OPLINE();
-       concat_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+       obj = Z_OBJ_P(object);
+       called_scope = obj->ce;
 
+       if (IS_CV != IS_CONST ||
+           EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
+           zend_object *orig_obj = obj;
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+               if (UNEXPECTED(obj->handlers->get_method == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Object does not support method calls");
+               }
 
-static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+               /* First, locate the function. */
+               fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_CV == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
+               if (UNEXPECTED(fbc == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
+               }
+               if (IS_CV == IS_CONST &&
+                   EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
+                   EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
+                   EXPECTED(obj == orig_obj)) {
+                       CACHE_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope, fbc);
+               }
+       }
 
+       if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_STATIC) != 0)) {
+               obj = NULL;
+       } else {
+               GC_REFCOUNT(obj)++; /* For $this pointer */
+       }
 
-       SAVE_OPLINE();
-       fast_is_identical_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+       EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
+               fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
 
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_CASE_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        zval *result = EX_VAR(opline->result.var);
 
        SAVE_OPLINE();
-       fast_is_not_identical_function(result,
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
+       fast_equal_function(result,
+                _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+                _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *result = EX_VAR(opline->result.var);
+       zval *expr_ptr, new_expr;
 
        SAVE_OPLINE();
-       fast_equal_function(result,
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
+       if ((IS_CV == IS_VAR || IS_CV == IS_CV) &&
+           (opline->extended_value & ZEND_ARRAY_ELEMENT_REF)) {
+               expr_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+               if (IS_CV == IS_VAR && UNEXPECTED(expr_ptr == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets");
+               }
+               ZVAL_MAKE_REF(expr_ptr);
+               Z_ADDREF_P(expr_ptr);
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+       } else {
+               expr_ptr = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+               if (IS_CV == IS_TMP_VAR) {
+                       ZVAL_COPY_VALUE(&new_expr, expr_ptr);
+                       expr_ptr = &new_expr;
+               } else if (IS_CV == IS_CONST) {
+                       if (!Z_IMMUTABLE_P(expr_ptr)) {
+                               ZVAL_DUP(&new_expr, expr_ptr);
+                               expr_ptr = &new_expr;
+                       }
+               } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(expr_ptr)) {
+                       expr_ptr = Z_REFVAL_P(expr_ptr);
+                       if (Z_REFCOUNTED_P(expr_ptr)) Z_ADDREF_P(expr_ptr);
 
-static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+               } else if (IS_CV == IS_CV && Z_REFCOUNTED_P(expr_ptr)) {
+                       Z_ADDREF_P(expr_ptr);
+               }
+       }
 
-       zval *result = EX_VAR(opline->result.var);
+       if (IS_CV != IS_UNUSED) {
 
-       SAVE_OPLINE();
-       fast_not_equal_function(result,
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+               zval *offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+               zend_string *str;
+               zend_ulong hval;
 
+add_again:
+               switch (Z_TYPE_P(offset)) {
+                       case IS_DOUBLE:
+                               hval = zend_dval_to_lval(Z_DVAL_P(offset));
+                               goto num_index;
+                       case IS_LONG:
+                               hval = Z_LVAL_P(offset);
+num_index:
+                               zend_hash_index_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), hval, expr_ptr);
+                               break;
+                       case IS_STRING:
+                               str = Z_STR_P(offset);
+                               if (IS_CV != IS_CONST) {
+                                       if (ZEND_HANDLE_NUMERIC(str, hval)) {
+                                               goto num_index;
+                                       }
+                               }
+str_index:
+                               zend_hash_update(Z_ARRVAL_P(EX_VAR(opline->result.var)), str, expr_ptr);
+                               break;
+                       case IS_NULL:
+                               str = STR_EMPTY_ALLOC();
+                               goto str_index;
+                       case IS_FALSE:
+                               hval = 0;
+                               goto num_index;
+                       case IS_TRUE:
+                               hval = 1;
+                               goto num_index;
+                       case IS_REFERENCE:
+                               offset = Z_REFVAL_P(offset);
+                               goto add_again;
+                               break;
+                       default:
+                               zend_error(E_WARNING, "Illegal offset type");
+                               zval_ptr_dtor(expr_ptr);
+                               /* do nothing */
+                               break;
+               }
 
+       } else {
+               zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
+       }
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
+       zval *array;
+       uint32_t size;
        USE_OPLINE
 
-       zval *result = EX_VAR(opline->result.var);
-
-       SAVE_OPLINE();
-       fast_is_smaller_function(result,
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+       array = EX_VAR(opline->result.var);
+       if (IS_CV != IS_UNUSED) {
+               size = opline->extended_value >> ZEND_ARRAY_SIZE_SHIFT;
+       } else {
+               size = 0;
+       }
+       ZVAL_NEW_ARR(array);
+       zend_hash_init(Z_ARRVAL_P(array), size, NULL, ZVAL_PTR_DTOR, 0);
 
+       if (IS_CV != IS_UNUSED) {
+               /* Explicitly initialize array as not-packed if flag is set */
+               if (opline->extended_value & ZEND_ARRAY_NOT_PACKED) {
+                       zend_hash_real_init(Z_ARRVAL_P(array), 0);
+               }
+       }
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       if (IS_CV == IS_UNUSED) {
+               ZEND_VM_NEXT_OPCODE();
+#if 0 || IS_CV != IS_UNUSED
+       } else {
+               return ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+#endif
+       }
 }
 
-static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *result = EX_VAR(opline->result.var);
+       zval *container;
+       zval *offset;
+       zend_ulong hval;
 
        SAVE_OPLINE();
-       fast_is_smaller_or_equal_function(result,
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+       container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
+       }
+       if (IS_CV != IS_UNUSED) {
+               ZVAL_DEREF(container);
+       }
+       SEPARATE_ZVAL_NOREF(container);
+       offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+
+       if (IS_CV != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
+               HashTable *ht = Z_ARRVAL_P(container);
+offset_again:
+               switch (Z_TYPE_P(offset)) {
+                       case IS_DOUBLE:
+                               hval = zend_dval_to_lval(Z_DVAL_P(offset));
+                               zend_hash_index_del(ht, hval);
+                               break;
+                       case IS_LONG:
+                               hval = Z_LVAL_P(offset);
+num_index_dim:
+                               zend_hash_index_del(ht, hval);
+                               break;
+                       case IS_STRING:
+                               if (IS_CV != IS_CONST) {
+                                       if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
+                                               goto num_index_dim;
+                                       }
+                               }
+                               if (ht == &EG(symbol_table).ht) {
+                                       zend_delete_global_variable(Z_STR_P(offset) TSRMLS_CC);
+                               } else {
+                                       zend_hash_del(ht, Z_STR_P(offset));
+                               }
+                               break;
+                       case IS_NULL:
+                               zend_hash_del(ht, STR_EMPTY_ALLOC());
+                               break;
+                       case IS_FALSE:
+                               hval = 0;
+                               goto num_index_dim;
+                       case IS_TRUE:
+                               hval = 1;
+                               goto num_index_dim;
+                       case IS_RESOURCE:
+                               hval = Z_RES_HANDLE_P(offset);
+                               goto num_index_dim;
+                       case IS_REFERENCE:
+                               offset = Z_REFVAL_P(offset);
+                               goto offset_again;
+                               break;
+                       default:
+                               zend_error(E_WARNING, "Illegal offset type in unset");
+                               break;
+               }
+
+       } else if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+               if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
+                       zend_error_noreturn(E_ERROR, "Cannot use object as array");
+               }
+//???          if (IS_CV == IS_CONST) {
+//???                  zval_copy_ctor(offset);
+//???          }
+               Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
+
+       } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
+               ZEND_VM_CONTINUE(); /* bailed out before */
+       } else {
 
+       }
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
+       zval *container;
+       zval *offset;
 
        SAVE_OPLINE();
-       bitwise_or_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+       container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
+       }
+       offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+
+       if (IS_CV != IS_UNUSED) {
+               ZVAL_DEREF(container);
+       }
+       if (IS_CV == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
+               if (Z_OBJ_HT_P(container)->unset_property) {
+                       Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+               } else {
+                       zend_error(E_NOTICE, "Trying to unset property of non-object");
+               }
+       }
 
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
+       zval *container;
+       int result;
+       zend_ulong hval;
+       zval *offset;
 
        SAVE_OPLINE();
-       bitwise_and_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
+       container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
+       offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+       if (IS_CV != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
+               HashTable *ht = Z_ARRVAL_P(container);
+               zval *value;
+               zend_string *str;
 
-static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+isset_again:
+               if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
+                       str = Z_STR_P(offset);
+                       if (IS_CV != IS_CONST) {
+                               if (ZEND_HANDLE_NUMERIC(str, hval)) {
+                                       goto num_index_prop;
+                               }
+                       }
+str_index_prop:
+                       value = zend_hash_find_ind(ht, str);
+               } else if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
+                       hval = Z_LVAL_P(offset);
+num_index_prop:
+                       value = zend_hash_index_find(ht, hval);
+               } else {
+                       switch (Z_TYPE_P(offset)) {
+                               case IS_DOUBLE:
+                                       hval = zend_dval_to_lval(Z_DVAL_P(offset));
+                                       goto num_index_prop;
+                               case IS_NULL:
+                                       str = STR_EMPTY_ALLOC();
+                                       goto str_index_prop;
+                               case IS_FALSE:
+                                       hval = 0;
+                                       goto num_index_prop;
+                               case IS_TRUE:
+                                       hval = 1;
+                                       goto num_index_prop;
+                               case IS_RESOURCE:
+                                       hval = Z_RES_HANDLE_P(offset);
+                                       goto num_index_prop;
+                               case IS_REFERENCE:
+                                       offset = Z_REFVAL_P(offset);
+                                       goto isset_again;
+                               default:
+                                       zend_error(E_WARNING, "Illegal offset type in isset or empty");
+                                       value = NULL;
+                                       break;
+                       }
+               }
 
+               if (opline->extended_value & ZEND_ISSET) {
+                       /* > IS_NULL means not IS_UNDEF and not IS_NULL */
+                       result = value != NULL && Z_TYPE_P(value) > IS_NULL &&
+                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL);
+               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+                       result = (value == NULL || !i_zend_is_true(value TSRMLS_CC));
+               }
+       } else if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+               if (EXPECTED(Z_OBJ_HT_P(container)->has_dimension)) {
+                       result = Z_OBJ_HT_P(container)->has_dimension(container, offset, (opline->extended_value & ZEND_ISSET) == 0 TSRMLS_CC);
+               } else {
+                       zend_error(E_NOTICE, "Trying to check element of non-array");
+                       result = 0;
+               }
+               if ((opline->extended_value & ZEND_ISSET) == 0) {
+                       result = !result;
+               }
+       } else if (EXPECTED(Z_TYPE_P(container) == IS_STRING)) { /* string offsets */
+               zval tmp;
 
-       SAVE_OPLINE();
-       bitwise_xor_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+               result = 0;
+               if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
+                       if (IS_CV & (IS_CV|IS_VAR)) {
+                               ZVAL_DEREF(offset);
+                       }
+                       if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
+                                       || (Z_TYPE_P(offset) == IS_STRING /* or numeric string */
+                                               && IS_LONG == is_numeric_string(Z_STRVAL_P(offset), Z_STRLEN_P(offset), NULL, NULL, 0))) {
+                               ZVAL_DUP(&tmp, offset);
+                               convert_to_long(&tmp);
+                               offset = &tmp;
+                       }
+               }
+               if (EXPECTED(Z_TYPE_P(offset) == IS_LONG)) {
+                       if (offset->value.lval >= 0 && (size_t)offset->value.lval < Z_STRLEN_P(container)) {
+                               if ((opline->extended_value & ZEND_ISSET) ||
+                                   Z_STRVAL_P(container)[offset->value.lval] != '0') {
+                                       result = 1;
+                               }
+                       }
+               }
+               if ((opline->extended_value & ZEND_ISSET) == 0) {
+                       result = !result;
+               }
+       } else {
+               result = ((opline->extended_value & ZEND_ISSET) == 0);
+       }
 
+       ZVAL_BOOL(EX_VAR(opline->result.var), result);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
+       zval *container;
+       int result;
+       zval *offset;
 
        SAVE_OPLINE();
-       boolean_xor_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+       container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
+       offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+
+       if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+               if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
+                       result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+               } else {
+                       zend_error(E_NOTICE, "Trying to check property of non-object");
+                       result = 0;
+               }
+               if ((opline->extended_value & ZEND_ISSET) == 0) {
+                       result = !result;
+               }
+       } else {
+               result = ((opline->extended_value & ZEND_ISSET) == 0);
+       }
 
+       ZVAL_BOOL(EX_VAR(opline->result.var), result);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_CV(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_YIELD_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op_data1;
-       zval *object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
-       zval *property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
-       zval *value;
-       zval *zptr;
 
-       if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
-       }
+       /* The generator object is stored in EX(return_value) */
+       zend_generator *generator = (zend_generator *) EX(return_value);
 
-       if (IS_CV != IS_UNUSED) {
-               object = make_real_object(object TSRMLS_CC);
+       if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
+               zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
        }
 
-       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
+       /* Destroy the previously yielded value */
+       zval_ptr_dtor(&generator->value);
 
-       if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
-               zend_error(E_WARNING, "Attempt to assign property of non-object");
+       /* Destroy the previously yielded key */
+       zval_ptr_dtor(&generator->key);
 
-               FREE_OP(free_op_data1);
+       /* Set the new yielded value */
+       if (IS_CV != IS_UNUSED) {
 
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
-               }
-       } else {
-               /* here we are sure we are dealing with an object */
-               if (opline->extended_value == ZEND_ASSIGN_OBJ
-                       && EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-                       && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
 
-                       ZVAL_DEREF(zptr);
-                       SEPARATE_ZVAL_NOREF(zptr);
+               if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
+                       /* Constants and temporary variables aren't yieldable by reference,
+                        * but we still allow them with a notice. */
+                       if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
+                               zval *value;
 
-                       binary_op(zptr, zptr, value TSRMLS_CC);
-                       if (RETURN_VALUE_USED(opline)) {
-                               ZVAL_COPY(EX_VAR(opline->result.var), zptr);
-                       }
-               } else {
-                       zval *z = NULL;
-                       zval rv;
+                               zend_error(E_NOTICE, "Only variable references should be yielded by reference");
 
-                       if (opline->extended_value == ZEND_ASSIGN_OBJ) {
-                               if (Z_OBJ_HT_P(object)->read_property) {
-                                       z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
-                               }
-                       } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
-                               if (Z_OBJ_HT_P(object)->read_dimension) {
-                                       z = Z_OBJ_HT_P(object)->read_dimension(object, property, BP_VAR_R, &rv TSRMLS_CC);
-                               }
-                       }
-                       if (z) {
-                               if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
-                                       zval rv;
-                                       zval *value = Z_OBJ_HT_P(z)->get(z, &rv TSRMLS_CC);
+                               value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+                               ZVAL_COPY_VALUE(&generator->value, value);
+                               if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
 
-                                       if (Z_REFCOUNT_P(z) == 0) {
-                                               zend_objects_store_del(Z_OBJ_P(z) TSRMLS_CC);
-                                       }
-                                       ZVAL_COPY_VALUE(z, value);
+                               /* Temporary variables don't need ctor copying */
+                               if (IS_CV != IS_TMP_VAR) {
+                                       zval_opt_copy_ctor(&generator->value);
                                }
-//???                          if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
-                               SEPARATE_ZVAL_IF_NOT_REF(z);
-                               binary_op(z, z, value TSRMLS_CC);
-                               if (opline->extended_value == ZEND_ASSIGN_OBJ) {
-                                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
-                               } else /* if (opline->extended_value == ZEND_ASSIGN_DIM) */ {
-                                       Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
+                       } else {
+                               zval *value_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
+
+                               if (IS_CV == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
+                                       zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
                                }
-                               if (RETURN_VALUE_USED(opline)) {
-                                       ZVAL_COPY(EX_VAR(opline->result.var), z);
+
+                               /* If a function call result is yielded and the function did
+                                * not return by reference we throw a notice. */
+                               if (IS_CV == IS_VAR &&
+                                   (value_ptr == &EG(uninitialized_zval) ||
+                                    (opline->extended_value == ZEND_RETURNS_FUNCTION &&
+                                     !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
+                                       zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+                               } else {
+                                       ZVAL_MAKE_REF(value_ptr);
                                }
-                               zval_ptr_dtor(z);
+                               ZVAL_COPY(&generator->value, value_ptr);
+
+                       }
+               } else {
+                       zval *value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
+
+                       /* Consts, temporary variables and references need copying */
+                       if (IS_CV == IS_CONST) {
+                               ZVAL_DUP(&generator->value, value);
+                       } else if (IS_CV == IS_TMP_VAR) {
+                               ZVAL_COPY_VALUE(&generator->value, value);
+            } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(value)) {
+                               ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
+
                        } else {
-                               zend_error(E_WARNING, "Attempt to assign property of non-object");
-                               if (RETURN_VALUE_USED(opline)) {
-                                       ZVAL_NULL(EX_VAR(opline->result.var));
+                               ZVAL_COPY_VALUE(&generator->value, value);
+                               if (IS_CV == IS_CV) {
+                                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
                                }
                        }
                }
-
-               FREE_OP(free_op_data1);
+       } else {
+               /* If no value was specified yield null */
+               ZVAL_NULL(&generator->value);
        }
 
-       /* assign_obj has two opcodes! */
-       CHECK_EXCEPTION();
-       ZEND_VM_INC_OPCODE();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL zend_binary_assign_op_dim_helper_SPEC_CV_CV(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op_data1;
-       zval *var_ptr, rv;
-       zval *value, *container;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-       }
+       /* Set the new yielded key */
        if (IS_CV != IS_UNUSED) {
-               ZVAL_DEREF(container);
-       }
-       if (IS_CV == IS_UNUSED || UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (IS_CV == IS_VAR && !0) {
-                       Z_ADDREF_P(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
-               }
-               return zend_binary_assign_op_obj_helper_SPEC_CV_CV(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else {
-               zval *dim = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
 
-               zend_fetch_dimension_address_RW(&rv, container, dim, IS_CV TSRMLS_CC);
-               value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-               ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
-               var_ptr = Z_INDIRECT(rv);
-       }
+               zval *key = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
 
-       if (UNEXPECTED(var_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
-       }
+               /* Consts, temporary variables and references need copying */
+               if (IS_CV == IS_CONST) {
+                       ZVAL_DUP(&generator->key, key);
+               } else if (IS_CV == IS_TMP_VAR) {
+                       ZVAL_COPY_VALUE(&generator->key, key);
+               } else if ((IS_CV == IS_VAR || IS_CV == IS_CV) && Z_ISREF_P(key)) {
+                       ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
 
-       if (UNEXPECTED(var_ptr == &EG(error_zval))) {
-               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
+               } else {
+                       ZVAL_COPY_VALUE(&generator->key, key);
+                       if (IS_CV == IS_CV) {
+                               if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
+                       }
                }
-       } else {
-               ZVAL_DEREF(var_ptr);
-               SEPARATE_ZVAL_NOREF(var_ptr);
-
-               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
 
-               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
+               if (Z_TYPE(generator->key) == IS_LONG
+                   && Z_LVAL(generator->key) > generator->largest_used_integer_key
+               ) {
+                       generator->largest_used_integer_key = Z_LVAL(generator->key);
                }
+       } else {
+               /* If no key was specified we use auto-increment keys */
+               generator->largest_used_integer_key++;
+               ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
        }
 
-       FREE_OP(free_op_data1);
+       if (RETURN_VALUE_USED(opline)) {
+               /* If the return value of yield is used set the send
+                * target and initialize it to NULL */
+               generator->send_target = EX_VAR(opline->result.var);
+               ZVAL_NULL(generator->send_target);
+       } else {
+               generator->send_target = NULL;
+       }
 
-       CHECK_EXCEPTION();
+       /* We increment to the next op, so we are at the correct position when the
+        * generator is resumed. */
        ZEND_VM_INC_OPCODE();
-       ZEND_VM_NEXT_OPCODE();
+
+       /* The GOTO VM uses a local opline variable. We need to set the opline
+        * variable in execute_data so we don't resume at an old position. */
+       SAVE_OPLINE();
+
+       ZEND_VM_RETURN();
 }
 
-static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_CV(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_POW_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
-       zval *var_ptr;
-       zval *value;
 
        SAVE_OPLINE();
-       value = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
-       var_ptr = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
-
-       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
-       }
-
-       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == &EG(error_zval))) {
-               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
-               }
-       } else {
-               ZVAL_DEREF(var_ptr);
-               SEPARATE_ZVAL_NOREF(var_ptr);
-
-               binary_op(var_ptr, var_ptr, value TSRMLS_CC);
-
-               if (UNEXPECTED(RETURN_VALUE_USED(opline))) {
-                       ZVAL_COPY(EX_VAR(opline->result.var), var_ptr);
-               }
-       }
+       pow_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_ADD_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_POW_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       USE_OPLINE
-
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_CV(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_CV(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_CV(add_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
+       return zend_binary_assign_op_helper_SPEC_CV_CV(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SUB_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ADD_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zend_free_op free_op2;
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_CV(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_CV(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_CV(sub_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_MUL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       SAVE_OPLINE();
+       fast_add_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_CV(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_CV(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_CV(mul_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
+       zval_ptr_dtor_nogc(free_op2);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_DIV_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_SUB_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zend_free_op free_op2;
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_CV(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_CV(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_CV(div_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_MOD_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       SAVE_OPLINE();
+       fast_sub_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_CV(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_CV(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_CV(mod_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
+       zval_ptr_dtor_nogc(free_op2);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_MUL_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zend_free_op free_op2;
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_CV(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_CV(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_CV(shift_left_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
+       SAVE_OPLINE();
+       fast_mul_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+
+       zval_ptr_dtor_nogc(free_op2);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_SR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_DIV_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zend_free_op free_op2;
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_CV(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_CV(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_CV(shift_right_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
+       SAVE_OPLINE();
+       fast_div_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+
+       zval_ptr_dtor_nogc(free_op2);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_CONCAT_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zend_free_op free_op2;
+       zval *result = EX_VAR(opline->result.var);
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_CV(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_CV(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_CV(concat_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
+       SAVE_OPLINE();
+       fast_equal_function(result,
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+
+       zval_ptr_dtor_nogc(free_op2);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_OR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zend_free_op free_op2;
+       zval *result = EX_VAR(opline->result.var);
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_CV(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_CV(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_CV(bitwise_or_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
+       SAVE_OPLINE();
+       fast_not_equal_function(result,
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+
+       zval_ptr_dtor_nogc(free_op2);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_AND_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zend_free_op free_op2;
+       zval *result = EX_VAR(opline->result.var);
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_CV(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_CV(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_CV(bitwise_and_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
+       SAVE_OPLINE();
+       fast_is_smaller_function(result,
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+
+       zval_ptr_dtor_nogc(free_op2);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zend_free_op free_op2;
+       zval *result = EX_VAR(opline->result.var);
 
-       if (EXPECTED(opline->extended_value == 0)) {
-               return zend_binary_assign_op_helper_SPEC_CV_CV(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (EXPECTED(opline->extended_value == ZEND_ASSIGN_DIM)) {
-               return zend_binary_assign_op_dim_helper_SPEC_CV_CV(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else /* if (EXPECTED(opline->extended_value == ZEND_ASSIGN_OBJ)) */ {
-               return zend_binary_assign_op_obj_helper_SPEC_CV_CV(bitwise_xor_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       }
+       SAVE_OPLINE();
+       fast_is_smaller_or_equal_function(result,
+               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+
+       zval_ptr_dtor_nogc(free_op2);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_CV(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_TMPVAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
+       zend_free_op free_op2;
        zval *object;
        zval *property;
        zval *retval;
@@ -41895,7 +36346,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_CV(incdec_t inc
 
        SAVE_OPLINE();
        object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
-       property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
        retval = EX_VAR(opline->result.var);
 
        if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
@@ -41908,7 +36359,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_CV(incdec_t inc
 
        if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-
+               zval_ptr_dtor_nogc(free_op2);
                if (RETURN_VALUE_USED(opline)) {
                        ZVAL_NULL(retval);
                }
@@ -41920,7 +36371,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_CV(incdec_t inc
        /* here we are sure we are dealing with an object */
 
        if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
 
                ZVAL_DEREF(zptr);
                SEPARATE_ZVAL_NOREF(zptr);
@@ -41933,7 +36384,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_CV(incdec_t inc
                zval rv;
 
                if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
-                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
 
                        if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval rv;
@@ -41948,7 +36399,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_CV(incdec_t inc
                        SEPARATE_ZVAL_IF_NOT_REF(z);
                        incdec_op(z);
                        ZVAL_COPY_VALUE(retval, z);
-                       Z_OBJ_HT_P(object)->write_property(object, property, z, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+                       Z_OBJ_HT_P(object)->write_property(object, property, z, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
                        SELECTIVE_PZVAL_LOCK(retval, opline);
                        zval_ptr_dtor(z);
                } else {
@@ -41959,25 +36410,26 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_CV(incdec_t inc
                }
        }
 
+       zval_ptr_dtor_nogc(free_op2);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_PRE_INC_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_PRE_INC_OBJ_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_pre_incdec_property_helper_SPEC_CV_CV(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_pre_incdec_property_helper_SPEC_CV_TMPVAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_pre_incdec_property_helper_SPEC_CV_CV(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_pre_incdec_property_helper_SPEC_CV_TMPVAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CV(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_TMPVAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
+       zend_free_op free_op2;
        zval *object;
        zval *property;
        zval *retval;
@@ -41985,7 +36437,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CV(incdec_t in
 
        SAVE_OPLINE();
        object = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
-       property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
        retval = EX_VAR(opline->result.var);
 
        if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
@@ -41998,7 +36450,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CV(incdec_t in
 
        if (IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-
+               zval_ptr_dtor_nogc(free_op2);
                ZVAL_NULL(retval);
 
                CHECK_EXCEPTION();
@@ -42008,7 +36460,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CV(incdec_t in
        /* here we are sure we are dealing with an object */
 
        if (EXPECTED(Z_OBJ_HT_P(object)->get_property_ptr_ptr)
-               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
+               && EXPECTED((zptr = Z_OBJ_HT_P(object)->get_property_ptr_ptr(object, property, BP_VAR_RW, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC)) != NULL)) {
 
                ZVAL_DEREF(zptr);
                ZVAL_COPY_VALUE(retval, zptr);
@@ -42018,7 +36470,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CV(incdec_t in
        } else {
                if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
                        zval rv;
-                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
+                       zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), &rv TSRMLS_CC);
                        zval z_copy;
 
                        if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
@@ -42034,7 +36486,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CV(incdec_t in
                        ZVAL_DUP(&z_copy, z);
                        incdec_op(&z_copy);
                        if (Z_REFCOUNTED_P(z)) Z_ADDREF_P(z);
-                       Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
+                       Z_OBJ_HT_P(object)->write_property(object, property, &z_copy, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL) TSRMLS_CC);
                        zval_ptr_dtor(&z_copy);
                        zval_ptr_dtor(z);
                } else {
@@ -42043,167 +36495,33 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CV(incdec_t in
                }
        }
 
+       zval_ptr_dtor_nogc(free_op2);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_POST_INC_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_post_incdec_property_helper_SPEC_CV_CV(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_post_incdec_property_helper_SPEC_CV_CV(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       zval *container;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-       zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
-
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *container;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-       }
-       ZVAL_DEREF(container);
-       zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
-
-       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-       }
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *container;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
-
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-       }
-       ZVAL_DEREF(container);
-       zend_fetch_dimension_address_RW(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
-
-       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-       }
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       zval *container;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
-       zend_fetch_dimension_address_read_IS(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
-
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_POST_INC_OBJ_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       USE_OPLINE
-       zval *container;
-       zend_free_op free_op1;
-
-       SAVE_OPLINE();
-
-       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
-        if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
-            zend_error_noreturn(E_ERROR, "Cannot use temporary expression in write context");
-        }
-               container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-                       zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-               }
-               ZVAL_DEREF(container);
-               zend_fetch_dimension_address_W(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
-               if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-                       EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-               }
-
-
-       } else {
-               if (IS_CV == IS_UNUSED) {
-                       zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
-               }
-               container = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-               zend_fetch_dimension_address_read_R(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
-
-
-       }
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       return zend_post_incdec_property_helper_SPEC_CV_TMPVAR(increment_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_DIM_UNSET_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *container;
-
-       SAVE_OPLINE();
-       container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
-
-       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-       }
-       ZVAL_DEREF(container);
-       zend_fetch_dimension_address_UNSET(EX_VAR(opline->result.var), container, _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC), IS_CV TSRMLS_CC);
-
-       if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
-               EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
-       }
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       return zend_post_incdec_property_helper_SPEC_CV_TMPVAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        zval *container;
-
+       zend_free_op free_op2;
        zval *offset;
 
        SAVE_OPLINE();
        container = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-       offset  = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+       offset  = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
        if ((IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
            UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
@@ -42214,7 +36532,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLE
 
                /* here we are sure we are dealing with an object */
                do {
-                       if (IS_CV == IS_CONST &&
+                       if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
                                EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
                                zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
                                zend_object *zobj = Z_OBJ_P(container);
@@ -42234,7 +36552,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLE
                                }
                        }
 
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
 
                        if (retval != EX_VAR(opline->result.var)) {
                                ZVAL_COPY(EX_VAR(opline->result.var), retval);
@@ -42242,28 +36560,29 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLE
                } while (0);
        }
 
+       zval_ptr_dtor_nogc(free_op2);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
+       zend_free_op free_op1, free_op2;
        zval *property;
        zval *container;
 
        SAVE_OPLINE();
-       property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
        container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
        if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
 
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CV, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
-
+       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
        if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
                EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
@@ -42272,22 +36591,22 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLE
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
+       zend_free_op free_op1, free_op2;
        zval *property;
        zval *container;
 
        SAVE_OPLINE();
-       property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
        container = _get_zval_ptr_cv_BP_VAR_RW(execute_data, opline->op1.var TSRMLS_CC);
 
        if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CV, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
-
+       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_RW TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
        if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
                EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
@@ -42296,17 +36615,17 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDL
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
        zval *container;
-
+       zend_free_op free_op2;
        zval *offset;
 
        SAVE_OPLINE();
        container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
-       offset  = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+       offset  = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
        if ((IS_CV != IS_UNUSED && UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT)) ||
            UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
@@ -42316,7 +36635,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDL
 
                /* here we are sure we are dealing with an object */
                do {
-                       if (IS_CV == IS_CONST &&
+                       if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
                                EXPECTED(Z_OBJCE_P(container) == CACHED_PTR(Z_CACHE_SLOT_P(offset)))) {
                                zend_property_info *prop_info = CACHED_PTR(Z_CACHE_SLOT_P(offset) + 1);
                                zend_object *zobj = Z_OBJ_P(container);
@@ -42336,7 +36655,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDL
                                }
                        }
 
-                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
+                       retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL), EX_VAR(opline->result.var) TSRMLS_CC);
 
                        if (retval != EX_VAR(opline->result.var)) {
                                ZVAL_COPY(EX_VAR(opline->result.var), retval);
@@ -42344,23 +36663,24 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDL
                } while (0);
        }
 
+       zval_ptr_dtor_nogc(free_op2);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zval *container;
 
        if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
                /* Behave like FETCH_OBJ_W */
-               zend_free_op free_op1;
+               zend_free_op free_op1, free_op2;
                zval *property;
 
                SAVE_OPLINE();
-               property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+               property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
                container = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
 
         if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
@@ -42369,8 +36689,8 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_CV_HANDLER(ZEND_OPCODE
                if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
                }
-               zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CV, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
-
+               zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_W TSRMLS_CC);
+               zval_ptr_dtor_nogc(free_op2);
                if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
                        EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
                }
@@ -42378,25 +36698,25 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_CV_HANDLER(ZEND_OPCODE
                CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
-               return ZEND_FETCH_OBJ_R_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return ZEND_FETCH_OBJ_R_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
+       zend_free_op free_op1, free_op2;
        zval *container, *property;
 
        SAVE_OPLINE();
        container = _get_zval_ptr_cv_BP_VAR_UNSET(execute_data, opline->op1.var TSRMLS_CC);
-       property = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+       property = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
        if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
-       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, IS_CV, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
-
+       zend_fetch_property_address(EX_VAR(opline->result.var), container, IS_CV, property, (IS_TMP_VAR|IS_VAR), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property)) : NULL), BP_VAR_UNSET TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
        if (IS_CV == IS_VAR && READY_TO_DESTROY(free_op1)) {
                EXTRACT_ZVAL_PTR(EX_VAR(opline->result.var));
        }
@@ -42405,22 +36725,22 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HA
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
+       zend_free_op free_op2;
        zval *object;
        zval *property_name;
 
        SAVE_OPLINE();
        object = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-       property_name = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+       property_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
        if (IS_CV == IS_VAR && UNEXPECTED(object == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
-
+       zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_OBJ, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op2);
 
        /* assign_obj has two opcodes! */
        CHECK_EXCEPTION();
@@ -42428,168 +36748,11 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       zval *object_ptr;
-
-       SAVE_OPLINE();
-       object_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-
-       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-       }
-       ZVAL_DEREF(object_ptr);
-       if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_OBJECT)) {
-
-               zval *property_name = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
-
-               zend_assign_to_object(RETURN_VALUE_USED(opline)?EX_VAR(opline->result.var):NULL, object_ptr, IS_CV, property_name, (opline+1)->op1_type, &(opline+1)->op1, execute_data, ZEND_ASSIGN_DIM, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(property_name)) : NULL) TSRMLS_CC);
-
-       } else {
-               zend_free_op free_op_data1;
-               zval  rv;
-               zval *value;
-               zval *dim = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
-               zval *variable_ptr;
-
-               if (UNEXPECTED(Z_TYPE_P(object_ptr) == IS_STRING) &&
-                   EXPECTED(Z_STRLEN_P(object_ptr) != 0)) {
-                       zend_long offset = zend_fetch_string_offset(object_ptr, dim, BP_VAR_W TSRMLS_CC);
-
-                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-                       zend_assign_to_string_offset(object_ptr, offset, value, (RETURN_VALUE_USED(opline) ? EX_VAR(opline->result.var) : NULL) TSRMLS_CC);
-                       FREE_OP(free_op_data1);
-               } else {
-                       zend_fetch_dimension_address_W(&rv, object_ptr, dim, IS_CV TSRMLS_CC);
-
-                       value = get_zval_ptr_deref((opline+1)->op1_type, &(opline+1)->op1, execute_data, &free_op_data1, BP_VAR_R);
-                       ZEND_ASSERT(Z_TYPE(rv) == IS_INDIRECT);
-                       variable_ptr = Z_INDIRECT(rv);
-                       if (UNEXPECTED(variable_ptr == &EG(error_zval))) {
-                               FREE_OP(free_op_data1);
-                               if (RETURN_VALUE_USED(opline)) {
-                                       ZVAL_NULL(EX_VAR(opline->result.var));
-                               }
-                       } else {
-                               value = zend_assign_to_variable(variable_ptr, value, (opline+1)->op1_type TSRMLS_CC);
-                               if ((opline+1)->op1_type == IS_VAR) {
-                                       FREE_OP(free_op_data1);
-                               }
-                               if (RETURN_VALUE_USED(opline)) {
-                                       ZVAL_COPY(EX_VAR(opline->result.var), value);
-                               }
-                       }
-               }
-       }
-
-       /* assign_dim has two opcodes! */
-       CHECK_EXCEPTION();
-       ZEND_VM_INC_OPCODE();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       zval *value;
-       zval *variable_ptr;
-
-       SAVE_OPLINE();
-       value = _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
-       variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-
-       if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) {
-               if (IS_CV == IS_TMP_VAR) {
-
-               }
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_NULL(EX_VAR(opline->result.var));
-               }
-       } else {
-               value = zend_assign_to_variable(variable_ptr, value, IS_CV TSRMLS_CC);
-               if (RETURN_VALUE_USED(opline)) {
-                       ZVAL_COPY(EX_VAR(opline->result.var), value);
-               }
-
-       }
-
-       /* zend_assign_to_variable() always takes care of op2, never free it! */
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_ASSIGN_REF_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-
-       zval *variable_ptr;
-       zval *value_ptr;
-
-       SAVE_OPLINE();
-       value_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op2.var TSRMLS_CC);
-
-       if (IS_CV == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
-       }
-       if (IS_CV == IS_VAR &&
-           (value_ptr == &EG(uninitialized_zval) ||
-            (opline->extended_value == ZEND_RETURNS_FUNCTION &&
-             !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
-               if (!0) {
-                       PZVAL_LOCK(value_ptr); /* undo the effect of get_zval_ptr_ptr() */
-               }
-               zend_error(E_STRICT, "Only variables should be assigned by reference");
-               if (UNEXPECTED(EG(exception) != NULL)) {
-
-                       HANDLE_EXCEPTION();
-               }
-               return ZEND_ASSIGN_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-       } else if (IS_CV == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
-               if (!0) {
-                       PZVAL_LOCK(value_ptr);
-               }
-       }
-
-       variable_ptr = _get_zval_ptr_cv_undef_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-       if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr == NULL)) {
-               zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
-       }
-       if (IS_CV == IS_VAR &&
-           UNEXPECTED(Z_TYPE_P(EX_VAR(opline->op1.var)) != IS_INDIRECT) &&
-           UNEXPECTED(!Z_ISREF_P(variable_ptr))) {
-               zend_error_noreturn(E_ERROR, "Cannot assign by reference to overloaded object");
-       }
-       if ((IS_CV == IS_VAR && UNEXPECTED(variable_ptr == &EG(error_zval))) ||
-           (IS_CV == IS_VAR && UNEXPECTED(value_ptr == &EG(error_zval)))) {
-               variable_ptr = &EG(uninitialized_zval);
-       } else {
-               zend_assign_to_variable_reference(variable_ptr, value_ptr TSRMLS_CC);
-       }
-
-       if (IS_CV == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
-               if (!0) {
-                       Z_DELREF_P(variable_ptr);
-               }
-       }
-
-       if (RETURN_VALUE_USED(opline)) {
-               ZVAL_COPY(EX_VAR(opline->result.var), variable_ptr);
-       }
-
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
-
-static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zval *function_name;
-
+       zend_free_op free_op2;
        zval *object;
        zend_function *fbc;
        zend_class_entry *called_scope;
@@ -42597,9 +36760,9 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_H
 
        SAVE_OPLINE();
 
-       function_name = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+       function_name = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
-       if (IS_CV != IS_CONST &&
+       if ((IS_TMP_VAR|IS_VAR) != IS_CONST &&
            UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                if (UNEXPECTED(EG(exception) != NULL)) {
                        HANDLE_EXCEPTION();
@@ -42613,12 +36776,12 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_H
                uint32_t nesting = 1;
 
                if (UNEXPECTED(EG(exception) != NULL)) {
-
+                       zval_ptr_dtor_nogc(free_op2);
                        HANDLE_EXCEPTION();
                }
 
                zend_error(E_RECOVERABLE_ERROR, "Call to a member function %s() on %s",  Z_STRVAL_P(function_name), zend_get_type_by_const(Z_TYPE_P(object)));
-
+               zval_ptr_dtor_nogc(free_op2);
 
                if (EG(exception) != NULL) {
                        HANDLE_EXCEPTION();
@@ -42656,7 +36819,7 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_H
        obj = Z_OBJ_P(object);
        called_scope = obj->ce;
 
-       if (IS_CV != IS_CONST ||
+       if ((IS_TMP_VAR|IS_VAR) != IS_CONST ||
            EXPECTED((fbc = CACHED_POLYMORPHIC_PTR(Z_CACHE_SLOT_P(function_name), called_scope)) == NULL)) {
            zend_object *orig_obj = obj;
 
@@ -42665,11 +36828,11 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_H
                }
 
                /* First, locate the function. */
-               fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), ((IS_CV == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
+               fbc = obj->handlers->get_method(&obj, Z_STR_P(function_name), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (opline->op2.zv + 1) : NULL) TSRMLS_CC);
                if (UNEXPECTED(fbc == NULL)) {
                        zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", obj->ce->name->val, Z_STRVAL_P(function_name));
                }
-               if (IS_CV == IS_CONST &&
+               if ((IS_TMP_VAR|IS_VAR) == IS_CONST &&
                    EXPECTED(fbc->type <= ZEND_USER_FUNCTION) &&
                    EXPECTED((fbc->common.fn_flags & (ZEND_ACC_CALL_VIA_HANDLER|ZEND_ACC_NEVER_CACHE)) == 0) &&
                    EXPECTED(obj == orig_obj)) {
@@ -42686,27 +36849,29 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_H
        EX(call) = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_FUNCTION,
                fbc, opline->extended_value, called_scope, obj, EX(call) TSRMLS_CC);
 
+       zval_ptr_dtor_nogc(free_op2);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_CASE_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_CASE_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
+       zend_free_op free_op2;
        zval *result = EX_VAR(opline->result.var);
 
        SAVE_OPLINE();
        fast_equal_function(result,
                 _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-                _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+                _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
 
+       zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
@@ -42741,9 +36906,9 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CV_HANDLER(ZEND_OPCODE_
                }
        }
 
-       if (IS_CV != IS_UNUSED) {
-
-               zval *offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+       if ((IS_TMP_VAR|IS_VAR) != IS_UNUSED) {
+               zend_free_op free_op2;
+               zval *offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
                zend_string *str;
                zend_ulong hval;
 
@@ -42759,7 +36924,7 @@ num_index:
                                break;
                        case IS_STRING:
                                str = Z_STR_P(offset);
-                               if (IS_CV != IS_CONST) {
+                               if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
                                        if (ZEND_HANDLE_NUMERIC(str, hval)) {
                                                goto num_index;
                                        }
@@ -42786,7 +36951,7 @@ str_index:
                                /* do nothing */
                                break;
                }
-
+               zval_ptr_dtor_nogc(free_op2);
        } else {
                zend_hash_next_index_insert(Z_ARRVAL_P(EX_VAR(opline->result.var)), expr_ptr);
        }
@@ -42794,7 +36959,7 @@ str_index:
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        zval *array;
        uint32_t size;
@@ -42820,15 +36985,15 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER
                ZEND_VM_NEXT_OPCODE();
 #if 0 || IS_CV != IS_UNUSED
        } else {
-               return ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 #endif
        }
 }
 
-static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
+       zend_free_op free_op2;
        zval *container;
        zval *offset;
        zend_ulong hval;
@@ -42842,7 +37007,7 @@ static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_
                ZVAL_DEREF(container);
        }
        SEPARATE_ZVAL_NOREF(container);
-       offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
        if (IS_CV != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
                HashTable *ht = Z_ARRVAL_P(container);
@@ -42858,7 +37023,7 @@ num_index_dim:
                                zend_hash_index_del(ht, hval);
                                break;
                        case IS_STRING:
-                               if (IS_CV != IS_CONST) {
+                               if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
                                        if (ZEND_HANDLE_NUMERIC(Z_STR_P(offset), hval)) {
                                                goto num_index_dim;
                                        }
@@ -42889,31 +37054,31 @@ num_index_dim:
                                zend_error(E_WARNING, "Illegal offset type in unset");
                                break;
                }
-
+               zval_ptr_dtor_nogc(free_op2);
        } else if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
                if (UNEXPECTED(Z_OBJ_HT_P(container)->unset_dimension == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use object as array");
                }
-//???          if (IS_CV == IS_CONST) {
+//???          if ((IS_TMP_VAR|IS_VAR) == IS_CONST) {
 //???                  zval_copy_ctor(offset);
 //???          }
                Z_OBJ_HT_P(container)->unset_dimension(container, offset TSRMLS_CC);
-
+               zval_ptr_dtor_nogc(free_op2);
        } else if (UNEXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
                zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
                ZEND_VM_CONTINUE(); /* bailed out before */
        } else {
-
+               zval_ptr_dtor_nogc(free_op2);
        }
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
+       zend_free_op free_op2;
        zval *container;
        zval *offset;
 
@@ -42922,28 +37087,28 @@ static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_
        if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
        }
-       offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
        if (IS_CV != IS_UNUSED) {
                ZVAL_DEREF(container);
        }
        if (IS_CV == IS_UNUSED || Z_TYPE_P(container) == IS_OBJECT) {
                if (Z_OBJ_HT_P(container)->unset_property) {
-                       Z_OBJ_HT_P(container)->unset_property(container, offset, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+                       Z_OBJ_HT_P(container)->unset_property(container, offset, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
                } else {
                        zend_error(E_NOTICE, "Trying to unset property of non-object");
                }
        }
-
+       zval_ptr_dtor_nogc(free_op2);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
+       zend_free_op free_op2;
        zval *container;
        int result;
        zend_ulong hval;
@@ -42951,7 +37116,7 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPC
 
        SAVE_OPLINE();
        container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
-       offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
+       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
 
        if (IS_CV != IS_UNUSED && EXPECTED(Z_TYPE_P(container) == IS_ARRAY)) {
                HashTable *ht = Z_ARRVAL_P(container);
@@ -42961,7 +37126,7 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPC
 isset_again:
                if (EXPECTED(Z_TYPE_P(offset) == IS_STRING)) {
                        str = Z_STR_P(offset);
-                       if (IS_CV != IS_CONST) {
+                       if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
                                if (ZEND_HANDLE_NUMERIC(str, hval)) {
                                        goto num_index_prop;
                                }
@@ -43021,7 +37186,7 @@ num_index_prop:
 
                result = 0;
                if (UNEXPECTED(Z_TYPE_P(offset) != IS_LONG)) {
-                       if (IS_CV == IS_CV || IS_CV == IS_VAR) {
+                       if ((IS_TMP_VAR|IS_VAR) & (IS_CV|IS_VAR)) {
                                ZVAL_DEREF(offset);
                        }
                        if (Z_TYPE_P(offset) < IS_STRING /* simple scalar types */
@@ -43047,451 +37212,1219 @@ num_index_prop:
                result = ((opline->extended_value & ZEND_ISSET) == 0);
        }
 
+       zval_ptr_dtor_nogc(free_op2);
+       ZVAL_BOOL(EX_VAR(opline->result.var), result);
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op2;
+       zval *container;
+       int result;
+       zval *offset;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
+       offset = _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2);
+
+       if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
+               if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
+                       result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
+               } else {
+                       zend_error(E_NOTICE, "Trying to check property of non-object");
+                       result = 0;
+               }
+               if ((opline->extended_value & ZEND_ISSET) == 0) {
+                       result = !result;
+               }
+       } else {
+               result = ((opline->extended_value & ZEND_ISSET) == 0);
+       }
+
+       zval_ptr_dtor_nogc(free_op2);
        ZVAL_BOOL(EX_VAR(opline->result.var), result);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FREE_SPEC_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       SAVE_OPLINE();
+       zval_ptr_dtor_nogc(EX_VAR(opline->op1.var));
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_BOOL_SPEC_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *retval = EX_VAR(opline->result.var);
+
+       SAVE_OPLINE();
+       /* PHP 3.0 returned "" for false and 1 for true, here we use 0 and 1 for now */
+       ZVAL_BOOL(retval, i_zend_is_true(_get_zval_ptr_var(opline->op1.var, execute_data, &free_op1) TSRMLS_CC));
+       zval_ptr_dtor_nogc(free_op1);
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_INCLUDE_OR_EVAL_SPEC_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_op_array *new_op_array=NULL;
+       zend_free_op free_op1;
+       zval *inc_filename;
+       zval tmp_inc_filename;
+       zend_bool failure_retval=0;
+
+       SAVE_OPLINE();
+       inc_filename = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+
+       ZVAL_UNDEF(&tmp_inc_filename);
+       if (Z_TYPE_P(inc_filename) != IS_STRING) {
+               ZVAL_STR(&tmp_inc_filename, zval_get_string(inc_filename));
+               inc_filename = &tmp_inc_filename;
+       }
+
+       if (opline->extended_value != ZEND_EVAL && strlen(Z_STRVAL_P(inc_filename)) != Z_STRLEN_P(inc_filename)) {
+               if (opline->extended_value == ZEND_INCLUDE_ONCE || opline->extended_value == ZEND_INCLUDE) {
+                       zend_message_dispatcher(ZMSG_FAILED_INCLUDE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
+               } else {
+                       zend_message_dispatcher(ZMSG_FAILED_REQUIRE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
+               }
+       } else {
+               switch (opline->extended_value) {
+                       case ZEND_INCLUDE_ONCE:
+                       case ZEND_REQUIRE_ONCE: {
+                                       zend_file_handle file_handle;
+                                       char *resolved_path;
+
+                                       resolved_path = zend_resolve_path(Z_STRVAL_P(inc_filename), (int)Z_STRLEN_P(inc_filename) TSRMLS_CC);
+                                       if (resolved_path) {
+                                               failure_retval = zend_hash_str_exists(&EG(included_files), resolved_path, (int)strlen(resolved_path));
+                                       } else {
+                                               resolved_path = Z_STRVAL_P(inc_filename);
+                                       }
+
+                                       if (failure_retval) {
+                                               /* do nothing, file already included */
+                                       } else if (SUCCESS == zend_stream_open(resolved_path, &file_handle TSRMLS_CC)) {
+
+                                               if (!file_handle.opened_path) {
+                                                       file_handle.opened_path = estrdup(resolved_path);
+                                               }
+
+                                               if (zend_hash_str_add_empty_element(&EG(included_files), file_handle.opened_path, (int)strlen(file_handle.opened_path))) {
+                                                       new_op_array = zend_compile_file(&file_handle, (opline->extended_value==ZEND_INCLUDE_ONCE?ZEND_INCLUDE:ZEND_REQUIRE) TSRMLS_CC);
+                                                       zend_destroy_file_handle(&file_handle TSRMLS_CC);
+                                               } else {
+                                                       zend_file_handle_dtor(&file_handle TSRMLS_CC);
+                                                       failure_retval=1;
+                                               }
+                                       } else {
+                                               if (opline->extended_value == ZEND_INCLUDE_ONCE) {
+                                                       zend_message_dispatcher(ZMSG_FAILED_INCLUDE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
+                                               } else {
+                                                       zend_message_dispatcher(ZMSG_FAILED_REQUIRE_FOPEN, Z_STRVAL_P(inc_filename) TSRMLS_CC);
+                                               }
+                                       }
+                                       if (resolved_path != Z_STRVAL_P(inc_filename)) {
+                                               efree(resolved_path);
+                                       }
+                               }
+                               break;
+                       case ZEND_INCLUDE:
+                       case ZEND_REQUIRE:
+                               new_op_array = compile_filename(opline->extended_value, inc_filename TSRMLS_CC);
+                               break;
+                       case ZEND_EVAL: {
+                                       char *eval_desc = zend_make_compiled_string_description("eval()'d code" TSRMLS_CC);
+
+                                       new_op_array = zend_compile_string(inc_filename, eval_desc TSRMLS_CC);
+                                       efree(eval_desc);
+                               }
+                               break;
+                       EMPTY_SWITCH_DEFAULT_CASE()
+               }
+       }
+       if (Z_TYPE(tmp_inc_filename) != IS_UNDEF) {
+               zend_string_release(Z_STR(tmp_inc_filename));
+       }
+       zval_ptr_dtor_nogc(free_op1);
+       if (UNEXPECTED(EG(exception) != NULL)) {
+               HANDLE_EXCEPTION();
+       } else if (EXPECTED(new_op_array != NULL)) {
+               zval *return_value = NULL;
+               zend_execute_data *call;
+
+               if (RETURN_VALUE_USED(opline)) {
+                       return_value = EX_VAR(opline->result.var);
+               }
+
+               new_op_array->scope = EG(scope); /* ??? */
+
+               call = zend_vm_stack_push_call_frame(ZEND_CALL_NESTED_CODE,
+                       (zend_function*)new_op_array, 0, EX(called_scope), Z_OBJ(EX(This)), NULL TSRMLS_CC);
+
+               if (EX(symbol_table)) {
+                       call->symbol_table = EX(symbol_table);
+               } else {
+                       call->symbol_table = zend_rebuild_symbol_table(TSRMLS_C);
+               }
+
+               call->prev_execute_data = execute_data;
+           i_init_code_execute_data(call, new_op_array, return_value TSRMLS_CC);
+               if (EXPECTED(zend_execute_ex == execute_ex)) {
+                       ZEND_VM_ENTER();
+               } else {
+                       ZEND_ADD_CALL_FLAG(call, ZEND_CALL_TOP);
+                       zend_execute_ex(call TSRMLS_CC);
+               }
+
+               destroy_op_array(new_op_array TSRMLS_CC);
+               efree_size(new_op_array, sizeof(zend_op_array));
+               if (UNEXPECTED(EG(exception) != NULL)) {
+                       zend_throw_exception_internal(NULL TSRMLS_CC);
+                       HANDLE_EXCEPTION();
+               }
+
+       } else if (RETURN_VALUE_USED(opline)) {
+               ZVAL_BOOL(EX_VAR(opline->result.var), failure_retval);
+       }
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_ADD_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+
+       SAVE_OPLINE();
+       fast_add_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
+               opline->op2.zv TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_SUB_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+
+       SAVE_OPLINE();
+       fast_sub_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
+               opline->op2.zv TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_MUL_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+
+       SAVE_OPLINE();
+       fast_mul_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
+               opline->op2.zv TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_DIV_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+
+       SAVE_OPLINE();
+       fast_div_function(EX_VAR(opline->result.var),
+               _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
+               opline->op2.zv TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *result = EX_VAR(opline->result.var);
+
+       SAVE_OPLINE();
+       fast_equal_function(result,
+               _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
+               opline->op2.zv TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-
-       zval *container;
-       int result;
-       zval *offset;
+       zend_free_op free_op1;
+       zval *result = EX_VAR(opline->result.var);
 
        SAVE_OPLINE();
-       container = _get_zval_ptr_cv_deref_BP_VAR_IS(execute_data, opline->op1.var TSRMLS_CC);
-       offset = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
-
-       if (IS_CV == IS_UNUSED || EXPECTED(Z_TYPE_P(container) == IS_OBJECT)) {
-               if (EXPECTED(Z_OBJ_HT_P(container)->has_property)) {
-                       result = Z_OBJ_HT_P(container)->has_property(container, offset, (opline->extended_value & ZEND_ISSET) == 0, ((IS_CV == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(offset)) : NULL) TSRMLS_CC);
-               } else {
-                       zend_error(E_NOTICE, "Trying to check property of non-object");
-                       result = 0;
-               }
-               if ((opline->extended_value & ZEND_ISSET) == 0) {
-                       result = !result;
-               }
-       } else {
-               result = ((opline->extended_value & ZEND_ISSET) == 0);
-       }
-
-       ZVAL_BOOL(EX_VAR(opline->result.var), result);
+       fast_not_equal_function(result,
+               _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
+               opline->op2.zv TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
 
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_YIELD_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zend_free_op free_op1;
+       zval *result = EX_VAR(opline->result.var);
 
-       /* The generator object is stored in EX(return_value) */
-       zend_generator *generator = (zend_generator *) EX(return_value);
+       SAVE_OPLINE();
+       fast_is_smaller_function(result,
+               _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
+               opline->op2.zv TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
 
-       if (generator->flags & ZEND_GENERATOR_FORCED_CLOSE) {
-               zend_error_noreturn(E_ERROR, "Cannot yield from finally in a force-closed generator");
-       }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       /* Destroy the previously yielded value */
-       zval_ptr_dtor(&generator->value);
+static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *result = EX_VAR(opline->result.var);
 
-       /* Destroy the previously yielded key */
-       zval_ptr_dtor(&generator->key);
+       SAVE_OPLINE();
+       fast_is_smaller_or_equal_function(result,
+               _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
+               opline->op2.zv TSRMLS_CC);
+       zval_ptr_dtor_nogc(free_op1);
 
-       /* Set the new yielded value */
-       if (IS_CV != IS_UNUSED) {
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
+static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_TMPVAR_CONST(int type, ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *varname;
+       zval *retval;
+       zend_string *name;
+       HashTable *target_symbol_table;
 
-               if (EX(func)->op_array.fn_flags & ZEND_ACC_RETURN_REFERENCE) {
-                       /* Constants and temporary variables aren't yieldable by reference,
-                        * but we still allow them with a notice. */
-                       if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
-                               zval *value;
+       SAVE_OPLINE();
+       varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
 
-                               zend_error(E_NOTICE, "Only variable references should be yielded by reference");
+       if ((IS_TMP_VAR|IS_VAR) == IS_CONST) {
+               name = Z_STR_P(varname);
+       } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
+               name = Z_STR_P(varname);
+               zend_string_addref(name);
+       } else {
+               name = zval_get_string(varname);
+       }
 
-                               value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-                               ZVAL_COPY_VALUE(&generator->value, value);
-                               if (Z_OPT_REFCOUNTED(generator->value)) Z_SET_REFCOUNT(generator->value, 1);
+       if (IS_CONST != IS_UNUSED) {
+               zend_class_entry *ce;
 
-                               /* Temporary variables don't need ctor copying */
-                               if (IS_CV != IS_TMP_VAR) {
-                                       zval_opt_copy_ctor(&generator->value);
-                               }
+               if (IS_CONST == IS_CONST) {
+                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
                        } else {
-                               zval *value_ptr = _get_zval_ptr_cv_BP_VAR_W(execute_data, opline->op1.var TSRMLS_CC);
-
-                               if (IS_CV == IS_VAR && UNEXPECTED(value_ptr == NULL)) {
-                                       zend_error_noreturn(E_ERROR, "Cannot yield string offsets by reference");
-                               }
-
-                               /* If a function call result is yielded and the function did
-                                * not return by reference we throw a notice. */
-                               if (IS_CV == IS_VAR &&
-                                   (value_ptr == &EG(uninitialized_zval) ||
-                                    (opline->extended_value == ZEND_RETURNS_FUNCTION &&
-                                     !(Z_VAR_FLAGS_P(value_ptr) & IS_VAR_RET_REF)))) {
-                                       zend_error(E_NOTICE, "Only variable references should be yielded by reference");
-                               } else {
-                                       ZVAL_MAKE_REF(value_ptr);
+                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+                               if (UNEXPECTED(ce == NULL)) {
+                                       if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+                                               zend_string_release(name);
+                                       }
+                                       zval_ptr_dtor_nogc(free_op1);
+                                       CHECK_EXCEPTION();
+                                       ZEND_VM_NEXT_OPCODE();
                                }
-                               ZVAL_COPY(&generator->value, value_ptr);
-
+                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
                        }
                } else {
-                       zval *value = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC);
-
-                       /* Consts, temporary variables and references need copying */
-                       if (IS_CV == IS_CONST) {
-                               ZVAL_DUP(&generator->value, value);
-                       } else if (IS_CV == IS_TMP_VAR) {
-                               ZVAL_COPY_VALUE(&generator->value, value);
-            } else if ((IS_CV == IS_CV || IS_CV == IS_VAR) && Z_ISREF_P(value)) {
-                               ZVAL_DUP(&generator->value, Z_REFVAL_P(value));
-
-                       } else {
-                               ZVAL_COPY_VALUE(&generator->value, value);
-                               if (IS_CV == IS_CV) {
-                                       if (Z_OPT_REFCOUNTED_P(value)) Z_ADDREF_P(value);
+                       ce = Z_CE_P(EX_VAR(opline->op2.var));
+               }
+               retval = zend_std_get_static_property(ce, name, 0, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+               zval_ptr_dtor_nogc(free_op1);
+       } else {
+               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+               retval = zend_hash_find(target_symbol_table, name);
+               if (retval == NULL) {
+                       switch (type) {
+                               case BP_VAR_R:
+                               case BP_VAR_UNSET:
+                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                       /* break missing intentionally */
+                               case BP_VAR_IS:
+                                       retval = &EG(uninitialized_zval);
+                                       break;
+                               case BP_VAR_RW:
+                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                       /* break missing intentionally */
+                               case BP_VAR_W:
+                                       retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
+                                       break;
+                               EMPTY_SWITCH_DEFAULT_CASE()
+                       }
+               /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
+               } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
+                       retval = Z_INDIRECT_P(retval);
+                       if (Z_TYPE_P(retval) == IS_UNDEF) {
+                               switch (type) {
+                                       case BP_VAR_R:
+                                       case BP_VAR_UNSET:
+                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                               /* break missing intentionally */
+                                       case BP_VAR_IS:
+                                               retval = &EG(uninitialized_zval);
+                                               break;
+                                       case BP_VAR_RW:
+                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                               /* break missing intentionally */
+                                       case BP_VAR_W:
+                                               ZVAL_NULL(retval);
+                                               break;
+                                       EMPTY_SWITCH_DEFAULT_CASE()
                                }
                        }
                }
-       } else {
-               /* If no value was specified yield null */
-               ZVAL_NULL(&generator->value);
-       }
-
-       /* Set the new yielded key */
-       if (IS_CV != IS_UNUSED) {
-
-               zval *key = _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC);
-
-               /* Consts, temporary variables and references need copying */
-               if (IS_CV == IS_CONST) {
-                       ZVAL_DUP(&generator->key, key);
-               } else if (IS_CV == IS_TMP_VAR) {
-                       ZVAL_COPY_VALUE(&generator->key, key);
-               } else if ((IS_CV == IS_VAR || IS_CV == IS_CV) && Z_ISREF_P(key)) {
-                       ZVAL_DUP(&generator->key, Z_REFVAL_P(key));
-
-               } else {
-                       ZVAL_COPY_VALUE(&generator->key, key);
-                       if (IS_CV == IS_CV) {
-                               if (Z_OPT_REFCOUNTED_P(key)) Z_ADDREF_P(key);
+               if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
+                       if (Z_CONSTANT_P(retval)) {
+                               zval_update_constant(retval, 1 TSRMLS_CC);
                        }
+               } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
+                       zval_ptr_dtor_nogc(free_op1);
                }
+       }
 
-               if (Z_TYPE(generator->key) == IS_LONG
-                   && Z_LVAL(generator->key) > generator->largest_used_integer_key
-               ) {
-                       generator->largest_used_integer_key = Z_LVAL(generator->key);
-               }
-       } else {
-               /* If no key was specified we use auto-increment keys */
-               generator->largest_used_integer_key++;
-               ZVAL_LONG(&generator->key, generator->largest_used_integer_key);
+       if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+               zend_string_release(name);
        }
 
-       if (RETURN_VALUE_USED(opline)) {
-               /* If the return value of yield is used set the send
-                * target and initialize it to NULL */
-               generator->send_target = EX_VAR(opline->result.var);
-               ZVAL_NULL(generator->send_target);
+       ZEND_ASSERT(retval != NULL);
+       if (type == BP_VAR_R || type == BP_VAR_IS) {
+               if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
+                       ZVAL_UNREF(retval);
+               }
+               ZVAL_COPY(EX_VAR(opline->result.var), retval);
        } else {
-               generator->send_target = NULL;
+               ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
        }
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
 
-       /* We increment to the next op, so we are at the correct position when the
-        * generator is resumed. */
-       ZEND_VM_INC_OPCODE();
+static int ZEND_FASTCALL  ZEND_FETCH_R_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_TMPVAR_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
 
-       /* The GOTO VM uses a local opline variable. We need to set the opline
-        * variable in execute_data so we don't resume at an old position. */
-       SAVE_OPLINE();
+static int ZEND_FASTCALL  ZEND_FETCH_W_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_TMPVAR_CONST(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
 
-       ZEND_VM_RETURN();
+static int ZEND_FASTCALL  ZEND_FETCH_RW_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_TMPVAR_CONST(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_POW_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_FUNC_ARG_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
 
+       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+               return zend_fetch_var_address_helper_SPEC_TMPVAR_CONST(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else {
+               return zend_fetch_var_address_helper_SPEC_TMPVAR_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
 
-       SAVE_OPLINE();
-       pow_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_cv_deref_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
-
-
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+static int ZEND_FASTCALL  ZEND_FETCH_UNSET_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_TMPVAR_CONST(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_ASSIGN_POW_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_IS_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_binary_assign_op_helper_SPEC_CV_CV(pow_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_fetch_var_address_helper_SPEC_TMPVAR_CONST(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_ADD_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_CASE_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
+       zend_free_op free_op1;
+       zval *result = EX_VAR(opline->result.var);
 
        SAVE_OPLINE();
-       fast_add_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       fast_equal_function(result,
+                _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
+                opline->op2.zv TSRMLS_CC);
 
-       zval_ptr_dtor_nogc(free_op2);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_SUB_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
+       zval tmp, *varname;
+       HashTable *target_symbol_table;
+       zend_free_op free_op1;
 
        SAVE_OPLINE();
-       fast_sub_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       if ((IS_TMP_VAR|IS_VAR) == IS_CV &&
+           IS_CONST == IS_UNUSED &&
+           (opline->extended_value & ZEND_QUICK_SET)) {
+               zval *var = EX_VAR(opline->op1.var);
 
-       zval_ptr_dtor_nogc(free_op2);
+               if (Z_REFCOUNTED_P(var)) {
+                       zend_refcounted *garbage = Z_COUNTED_P(var);
+
+                       if (!--GC_REFCOUNT(garbage)) {
+                               ZVAL_UNDEF(var);
+                               _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
+                       } else {
+                               GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
+                               ZVAL_UNDEF(var);
+                       }
+               } else {
+                       ZVAL_UNDEF(var);
+               }
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
+       }
+
+       varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+
+       ZVAL_UNDEF(&tmp);
+       if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
+               ZVAL_STR(&tmp, zval_get_string(varname));
+               varname = &tmp;
+       }
+
+       if (IS_CONST != IS_UNUSED) {
+               zend_class_entry *ce;
+
+               if (IS_CONST == IS_CONST) {
+                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+                       } else {
+                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+                               if (UNEXPECTED(EG(exception) != NULL)) {
+                                       if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+                                               zend_string_release(Z_STR(tmp));
+                                       }
+                                       zval_ptr_dtor_nogc(free_op1);
+                                       HANDLE_EXCEPTION();
+                               }
+                               if (UNEXPECTED(ce == NULL)) {
+                                       zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
+                               }
+                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+                       }
+               } else {
+                       ce = Z_CE_P(EX_VAR(opline->op2.var));
+               }
+               zend_std_unset_static_property(ce, Z_STR_P(varname), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+       } else {
+               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+               zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
+       }
+
+       if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+               zend_string_release(Z_STR(tmp));
+       }
+       zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_MUL_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
+       zval *value;
 
        SAVE_OPLINE();
-       fast_mul_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       if ((IS_TMP_VAR|IS_VAR) == IS_CV &&
+           IS_CONST == IS_UNUSED &&
+           (opline->extended_value & ZEND_QUICK_SET)) {
+               value = EX_VAR(opline->op1.var);
+               if (opline->extended_value & ZEND_ISSET) {
+                       ZVAL_BOOL(EX_VAR(opline->result.var),
+                               Z_TYPE_P(value) > IS_NULL &&
+                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+                       ZVAL_BOOL(EX_VAR(opline->result.var),
+                               !i_zend_is_true(value TSRMLS_CC));
+                       CHECK_EXCEPTION();
+               }
+               ZEND_VM_NEXT_OPCODE();
+       } else {
+               zend_free_op free_op1;
+               zval tmp, *varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
 
-       zval_ptr_dtor_nogc(free_op2);
+               ZVAL_UNDEF(&tmp);
+               if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
+                       ZVAL_STR(&tmp, zval_get_string(varname));
+                       varname = &tmp;
+               }
+
+               if (IS_CONST != IS_UNUSED) {
+                       zend_class_entry *ce;
+
+                       if (IS_CONST == IS_CONST) {
+                               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                                       ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+                               } else {
+                                       ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+                                       if (UNEXPECTED(ce == NULL)) {
+                                               CHECK_EXCEPTION();
+                                               ZEND_VM_NEXT_OPCODE();
+                                       }
+                                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+                               }
+                       } else {
+                               ce = Z_CE_P(EX_VAR(opline->op2.var));
+                       }
+                       value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+               } else {
+                       HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+                       value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
+               }
+
+               if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+                       zend_string_release(Z_STR(tmp));
+               }
+               zval_ptr_dtor_nogc(free_op1);
+
+               if (opline->extended_value & ZEND_ISSET) {
+                       ZVAL_BOOL(EX_VAR(opline->result.var),
+                               value && Z_TYPE_P(value) > IS_NULL &&
+                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+                       ZVAL_BOOL(EX_VAR(opline->result.var),
+                               !value || !i_zend_is_true(value TSRMLS_CC));
+               }
+
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
+       }
+}
+
+static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_TMPVAR_VAR(int type, ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *varname;
+       zval *retval;
+       zend_string *name;
+       HashTable *target_symbol_table;
+
+       SAVE_OPLINE();
+       varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+
+       if ((IS_TMP_VAR|IS_VAR) == IS_CONST) {
+               name = Z_STR_P(varname);
+       } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
+               name = Z_STR_P(varname);
+               zend_string_addref(name);
+       } else {
+               name = zval_get_string(varname);
+       }
+
+       if (IS_VAR != IS_UNUSED) {
+               zend_class_entry *ce;
+
+               if (IS_VAR == IS_CONST) {
+                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+                       } else {
+                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+                               if (UNEXPECTED(ce == NULL)) {
+                                       if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+                                               zend_string_release(name);
+                                       }
+                                       zval_ptr_dtor_nogc(free_op1);
+                                       CHECK_EXCEPTION();
+                                       ZEND_VM_NEXT_OPCODE();
+                               }
+                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+                       }
+               } else {
+                       ce = Z_CE_P(EX_VAR(opline->op2.var));
+               }
+               retval = zend_std_get_static_property(ce, name, 0, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+               zval_ptr_dtor_nogc(free_op1);
+       } else {
+               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+               retval = zend_hash_find(target_symbol_table, name);
+               if (retval == NULL) {
+                       switch (type) {
+                               case BP_VAR_R:
+                               case BP_VAR_UNSET:
+                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                       /* break missing intentionally */
+                               case BP_VAR_IS:
+                                       retval = &EG(uninitialized_zval);
+                                       break;
+                               case BP_VAR_RW:
+                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                       /* break missing intentionally */
+                               case BP_VAR_W:
+                                       retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
+                                       break;
+                               EMPTY_SWITCH_DEFAULT_CASE()
+                       }
+               /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
+               } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
+                       retval = Z_INDIRECT_P(retval);
+                       if (Z_TYPE_P(retval) == IS_UNDEF) {
+                               switch (type) {
+                                       case BP_VAR_R:
+                                       case BP_VAR_UNSET:
+                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                               /* break missing intentionally */
+                                       case BP_VAR_IS:
+                                               retval = &EG(uninitialized_zval);
+                                               break;
+                                       case BP_VAR_RW:
+                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                               /* break missing intentionally */
+                                       case BP_VAR_W:
+                                               ZVAL_NULL(retval);
+                                               break;
+                                       EMPTY_SWITCH_DEFAULT_CASE()
+                               }
+                       }
+               }
+               if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
+                       if (Z_CONSTANT_P(retval)) {
+                               zval_update_constant(retval, 1 TSRMLS_CC);
+                       }
+               } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
+                       zval_ptr_dtor_nogc(free_op1);
+               }
+       }
+
+       if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+               zend_string_release(name);
+       }
+
+       ZEND_ASSERT(retval != NULL);
+       if (type == BP_VAR_R || type == BP_VAR_IS) {
+               if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
+                       ZVAL_UNREF(retval);
+               }
+               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+       } else {
+               ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
+       }
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_DIV_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_R_SPEC_TMPVAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       USE_OPLINE
-       zend_free_op free_op2;
+       return zend_fetch_var_address_helper_SPEC_TMPVAR_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
 
-       SAVE_OPLINE();
-       fast_div_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+static int ZEND_FASTCALL  ZEND_FETCH_W_SPEC_TMPVAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_TMPVAR_VAR(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
 
-       zval_ptr_dtor_nogc(free_op2);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+static int ZEND_FASTCALL  ZEND_FETCH_RW_SPEC_TMPVAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_TMPVAR_VAR(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_FUNC_ARG_SPEC_TMPVAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
-       zval *result = EX_VAR(opline->result.var);
-
-       SAVE_OPLINE();
-       fast_equal_function(result,
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
 
-       zval_ptr_dtor_nogc(free_op2);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+               return zend_fetch_var_address_helper_SPEC_TMPVAR_VAR(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else {
+               return zend_fetch_var_address_helper_SPEC_TMPVAR_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
 }
 
-static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_UNSET_SPEC_TMPVAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       USE_OPLINE
-       zend_free_op free_op2;
-       zval *result = EX_VAR(opline->result.var);
-
-       SAVE_OPLINE();
-       fast_not_equal_function(result,
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       return zend_fetch_var_address_helper_SPEC_TMPVAR_VAR(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
 
-       zval_ptr_dtor_nogc(free_op2);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+static int ZEND_FASTCALL  ZEND_FETCH_IS_SPEC_TMPVAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_TMPVAR_VAR(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_TMPVAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op2;
-       zval *result = EX_VAR(opline->result.var);
+       zval tmp, *varname;
+       HashTable *target_symbol_table;
+       zend_free_op free_op1;
 
        SAVE_OPLINE();
-       fast_is_smaller_function(result,
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       if ((IS_TMP_VAR|IS_VAR) == IS_CV &&
+           IS_VAR == IS_UNUSED &&
+           (opline->extended_value & ZEND_QUICK_SET)) {
+               zval *var = EX_VAR(opline->op1.var);
 
-       zval_ptr_dtor_nogc(free_op2);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+               if (Z_REFCOUNTED_P(var)) {
+                       zend_refcounted *garbage = Z_COUNTED_P(var);
 
-static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_CV_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op2;
-       zval *result = EX_VAR(opline->result.var);
+                       if (!--GC_REFCOUNT(garbage)) {
+                               ZVAL_UNDEF(var);
+                               _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
+                       } else {
+                               GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
+                               ZVAL_UNDEF(var);
+                       }
+               } else {
+                       ZVAL_UNDEF(var);
+               }
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
+       }
 
-       SAVE_OPLINE();
-       fast_is_smaller_or_equal_function(result,
-               _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op1.var TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+       varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
 
-       zval_ptr_dtor_nogc(free_op2);
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+       ZVAL_UNDEF(&tmp);
+       if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
+               ZVAL_STR(&tmp, zval_get_string(varname));
+               varname = &tmp;
+       }
 
-static int ZEND_FASTCALL  ZEND_FREE_SPEC_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
+       if (IS_VAR != IS_UNUSED) {
+               zend_class_entry *ce;
 
-       SAVE_OPLINE();
-       zval_ptr_dtor_nogc(EX_VAR(opline->op1.var));
+               if (IS_VAR == IS_CONST) {
+                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+                       } else {
+                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+                               if (UNEXPECTED(EG(exception) != NULL)) {
+                                       if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+                                               zend_string_release(Z_STR(tmp));
+                                       }
+                                       zval_ptr_dtor_nogc(free_op1);
+                                       HANDLE_EXCEPTION();
+                               }
+                               if (UNEXPECTED(ce == NULL)) {
+                                       zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
+                               }
+                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+                       }
+               } else {
+                       ce = Z_CE_P(EX_VAR(opline->op2.var));
+               }
+               zend_std_unset_static_property(ce, Z_STR_P(varname), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+       } else {
+               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+               zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
+       }
+
+       if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+               zend_string_release(Z_STR(tmp));
+       }
+       zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_ADD_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_TMPVAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
+       zval *value;
 
        SAVE_OPLINE();
-       fast_add_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
-               opline->op2.zv TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
+       if ((IS_TMP_VAR|IS_VAR) == IS_CV &&
+           IS_VAR == IS_UNUSED &&
+           (opline->extended_value & ZEND_QUICK_SET)) {
+               value = EX_VAR(opline->op1.var);
+               if (opline->extended_value & ZEND_ISSET) {
+                       ZVAL_BOOL(EX_VAR(opline->result.var),
+                               Z_TYPE_P(value) > IS_NULL &&
+                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+                       ZVAL_BOOL(EX_VAR(opline->result.var),
+                               !i_zend_is_true(value TSRMLS_CC));
+                       CHECK_EXCEPTION();
+               }
+               ZEND_VM_NEXT_OPCODE();
+       } else {
+               zend_free_op free_op1;
+               zval tmp, *varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+               ZVAL_UNDEF(&tmp);
+               if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
+                       ZVAL_STR(&tmp, zval_get_string(varname));
+                       varname = &tmp;
+               }
 
-static int ZEND_FASTCALL  ZEND_SUB_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
+               if (IS_VAR != IS_UNUSED) {
+                       zend_class_entry *ce;
 
-       SAVE_OPLINE();
-       fast_sub_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
-               opline->op2.zv TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
+                       if (IS_VAR == IS_CONST) {
+                               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                                       ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+                               } else {
+                                       ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+                                       if (UNEXPECTED(ce == NULL)) {
+                                               CHECK_EXCEPTION();
+                                               ZEND_VM_NEXT_OPCODE();
+                                       }
+                                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+                               }
+                       } else {
+                               ce = Z_CE_P(EX_VAR(opline->op2.var));
+                       }
+                       value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+               } else {
+                       HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+                       value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
+               }
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+               if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+                       zend_string_release(Z_STR(tmp));
+               }
+               zval_ptr_dtor_nogc(free_op1);
+
+               if (opline->extended_value & ZEND_ISSET) {
+                       ZVAL_BOOL(EX_VAR(opline->result.var),
+                               value && Z_TYPE_P(value) > IS_NULL &&
+                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+                       ZVAL_BOOL(EX_VAR(opline->result.var),
+                               !value || !i_zend_is_true(value TSRMLS_CC));
+               }
+
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
+       }
 }
 
-static int ZEND_FASTCALL  ZEND_MUL_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_TMPVAR_UNUSED(int type, ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
        zend_free_op free_op1;
+       zval *varname;
+       zval *retval;
+       zend_string *name;
+       HashTable *target_symbol_table;
 
        SAVE_OPLINE();
-       fast_mul_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
-               opline->op2.zv TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
+       varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
-}
+       if ((IS_TMP_VAR|IS_VAR) == IS_CONST) {
+               name = Z_STR_P(varname);
+       } else if (EXPECTED(Z_TYPE_P(varname) == IS_STRING)) {
+               name = Z_STR_P(varname);
+               zend_string_addref(name);
+       } else {
+               name = zval_get_string(varname);
+       }
 
-static int ZEND_FASTCALL  ZEND_DIV_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       USE_OPLINE
-       zend_free_op free_op1;
+       if (IS_UNUSED != IS_UNUSED) {
+               zend_class_entry *ce;
 
-       SAVE_OPLINE();
-       fast_div_function(EX_VAR(opline->result.var),
-               _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
-               opline->op2.zv TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
+               if (IS_UNUSED == IS_CONST) {
+                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+                       } else {
+                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+                               if (UNEXPECTED(ce == NULL)) {
+                                       if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+                                               zend_string_release(name);
+                                       }
+                                       zval_ptr_dtor_nogc(free_op1);
+                                       CHECK_EXCEPTION();
+                                       ZEND_VM_NEXT_OPCODE();
+                               }
+                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+                       }
+               } else {
+                       ce = Z_CE_P(EX_VAR(opline->op2.var));
+               }
+               retval = zend_std_get_static_property(ce, name, 0, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+               zval_ptr_dtor_nogc(free_op1);
+       } else {
+               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+               retval = zend_hash_find(target_symbol_table, name);
+               if (retval == NULL) {
+                       switch (type) {
+                               case BP_VAR_R:
+                               case BP_VAR_UNSET:
+                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                       /* break missing intentionally */
+                               case BP_VAR_IS:
+                                       retval = &EG(uninitialized_zval);
+                                       break;
+                               case BP_VAR_RW:
+                                       zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                       /* break missing intentionally */
+                               case BP_VAR_W:
+                                       retval = zend_hash_add_new(target_symbol_table, name, &EG(uninitialized_zval));
+                                       break;
+                               EMPTY_SWITCH_DEFAULT_CASE()
+                       }
+               /* GLOBAL or $$name variable may be an INDIRECT pointer to CV */
+               } else if (Z_TYPE_P(retval) == IS_INDIRECT) {
+                       retval = Z_INDIRECT_P(retval);
+                       if (Z_TYPE_P(retval) == IS_UNDEF) {
+                               switch (type) {
+                                       case BP_VAR_R:
+                                       case BP_VAR_UNSET:
+                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                               /* break missing intentionally */
+                                       case BP_VAR_IS:
+                                               retval = &EG(uninitialized_zval);
+                                               break;
+                                       case BP_VAR_RW:
+                                               zend_error(E_NOTICE,"Undefined variable: %s", name->val);
+                                               /* break missing intentionally */
+                                       case BP_VAR_W:
+                                               ZVAL_NULL(retval);
+                                               break;
+                                       EMPTY_SWITCH_DEFAULT_CASE()
+                               }
+                       }
+               }
+               if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) == ZEND_FETCH_STATIC) {
+                       if (Z_CONSTANT_P(retval)) {
+                               zval_update_constant(retval, 1 TSRMLS_CC);
+                       }
+               } else if ((opline->extended_value & ZEND_FETCH_TYPE_MASK) != ZEND_FETCH_GLOBAL_LOCK) {
+                       zval_ptr_dtor_nogc(free_op1);
+               }
+       }
 
+       if ((IS_TMP_VAR|IS_VAR) != IS_CONST) {
+               zend_string_release(name);
+       }
+
+       ZEND_ASSERT(retval != NULL);
+       if (type == BP_VAR_R || type == BP_VAR_IS) {
+               if (/*type == BP_VAR_R &&*/ Z_ISREF_P(retval) && Z_REFCOUNT_P(retval) == 1) {
+                       ZVAL_UNREF(retval);
+               }
+               ZVAL_COPY(EX_VAR(opline->result.var), retval);
+       } else {
+               ZVAL_INDIRECT(EX_VAR(opline->result.var), retval);
+       }
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_R_SPEC_TMPVAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       USE_OPLINE
-       zend_free_op free_op1;
-       zval *result = EX_VAR(opline->result.var);
+       return zend_fetch_var_address_helper_SPEC_TMPVAR_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
 
-       SAVE_OPLINE();
-       fast_equal_function(result,
-               _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
-               opline->op2.zv TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
+static int ZEND_FASTCALL  ZEND_FETCH_W_SPEC_TMPVAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_TMPVAR_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+static int ZEND_FASTCALL  ZEND_FETCH_RW_SPEC_TMPVAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_TMPVAR_UNUSED(BP_VAR_RW, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_FUNC_ARG_SPEC_TMPVAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
-       zval *result = EX_VAR(opline->result.var);
 
-       SAVE_OPLINE();
-       fast_not_equal_function(result,
-               _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
-               opline->op2.zv TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
+       if (zend_is_by_ref_func_arg_fetch(opline, EX(call) TSRMLS_CC)) {
+               return zend_fetch_var_address_helper_SPEC_TMPVAR_UNUSED(BP_VAR_W, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       } else {
+               return zend_fetch_var_address_helper_SPEC_TMPVAR_UNUSED(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
+}
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+static int ZEND_FASTCALL  ZEND_FETCH_UNSET_SPEC_TMPVAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_TMPVAR_UNUSED(BP_VAR_UNSET, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_FETCH_IS_SPEC_TMPVAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       return zend_fetch_var_address_helper_SPEC_TMPVAR_UNUSED(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+}
+
+static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_TMPVAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
+       zval tmp, *varname;
+       HashTable *target_symbol_table;
        zend_free_op free_op1;
-       zval *result = EX_VAR(opline->result.var);
 
        SAVE_OPLINE();
-       fast_is_smaller_function(result,
-               _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
-               opline->op2.zv TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
+       if ((IS_TMP_VAR|IS_VAR) == IS_CV &&
+           IS_UNUSED == IS_UNUSED &&
+           (opline->extended_value & ZEND_QUICK_SET)) {
+               zval *var = EX_VAR(opline->op1.var);
+
+               if (Z_REFCOUNTED_P(var)) {
+                       zend_refcounted *garbage = Z_COUNTED_P(var);
+
+                       if (!--GC_REFCOUNT(garbage)) {
+                               ZVAL_UNDEF(var);
+                               _zval_dtor_func_for_ptr(garbage ZEND_FILE_LINE_CC);
+                       } else {
+                               GC_ZVAL_CHECK_POSSIBLE_ROOT(var);
+                               ZVAL_UNDEF(var);
+                       }
+               } else {
+                       ZVAL_UNDEF(var);
+               }
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
+       }
+
+       varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
+
+       ZVAL_UNDEF(&tmp);
+       if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
+               ZVAL_STR(&tmp, zval_get_string(varname));
+               varname = &tmp;
+       }
 
+       if (IS_UNUSED != IS_UNUSED) {
+               zend_class_entry *ce;
+
+               if (IS_UNUSED == IS_CONST) {
+                       if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                               ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+                       } else {
+                               ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+                               if (UNEXPECTED(EG(exception) != NULL)) {
+                                       if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+                                               zend_string_release(Z_STR(tmp));
+                                       }
+                                       zval_ptr_dtor_nogc(free_op1);
+                                       HANDLE_EXCEPTION();
+                               }
+                               if (UNEXPECTED(ce == NULL)) {
+                                       zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op2.zv));
+                               }
+                               CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+                       }
+               } else {
+                       ce = Z_CE_P(EX_VAR(opline->op2.var));
+               }
+               zend_std_unset_static_property(ce, Z_STR_P(varname), (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+       } else {
+               target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+               zend_hash_del_ind(target_symbol_table, Z_STR_P(varname));
+       }
+
+       if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+               zend_string_release(Z_STR(tmp));
+       }
+       zval_ptr_dtor_nogc(free_op1);
        CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_TMPVAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_TMPVAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
-       zend_free_op free_op1;
-       zval *result = EX_VAR(opline->result.var);
+       zval *value;
 
        SAVE_OPLINE();
-       fast_is_smaller_or_equal_function(result,
-               _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
-               opline->op2.zv TSRMLS_CC);
-       zval_ptr_dtor_nogc(free_op1);
+       if ((IS_TMP_VAR|IS_VAR) == IS_CV &&
+           IS_UNUSED == IS_UNUSED &&
+           (opline->extended_value & ZEND_QUICK_SET)) {
+               value = EX_VAR(opline->op1.var);
+               if (opline->extended_value & ZEND_ISSET) {
+                       ZVAL_BOOL(EX_VAR(opline->result.var),
+                               Z_TYPE_P(value) > IS_NULL &&
+                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+                       ZVAL_BOOL(EX_VAR(opline->result.var),
+                               !i_zend_is_true(value TSRMLS_CC));
+                       CHECK_EXCEPTION();
+               }
+               ZEND_VM_NEXT_OPCODE();
+       } else {
+               zend_free_op free_op1;
+               zval tmp, *varname = _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1);
 
-       CHECK_EXCEPTION();
-       ZEND_VM_NEXT_OPCODE();
+               ZVAL_UNDEF(&tmp);
+               if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
+                       ZVAL_STR(&tmp, zval_get_string(varname));
+                       varname = &tmp;
+               }
+
+               if (IS_UNUSED != IS_UNUSED) {
+                       zend_class_entry *ce;
+
+                       if (IS_UNUSED == IS_CONST) {
+                               if (CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv))) {
+                                       ce = CACHED_PTR(Z_CACHE_SLOT_P(opline->op2.zv));
+                               } else {
+                                       ce = zend_fetch_class_by_name(Z_STR_P(opline->op2.zv), opline->op2.zv + 1, 0 TSRMLS_CC);
+                                       if (UNEXPECTED(ce == NULL)) {
+                                               CHECK_EXCEPTION();
+                                               ZEND_VM_NEXT_OPCODE();
+                                       }
+                                       CACHE_PTR(Z_CACHE_SLOT_P(opline->op2.zv), ce);
+                               }
+                       } else {
+                               ce = Z_CE_P(EX_VAR(opline->op2.var));
+                       }
+                       value = zend_std_get_static_property(ce, Z_STR_P(varname), 1, (((IS_TMP_VAR|IS_VAR) == IS_CONST) ? (EX(run_time_cache) + Z_CACHE_SLOT_P(varname)) : NULL) TSRMLS_CC);
+               } else {
+                       HashTable *target_symbol_table = zend_get_target_symbol_table(execute_data, opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
+                       value = zend_hash_find_ind(target_symbol_table, Z_STR_P(varname));
+               }
+
+               if ((IS_TMP_VAR|IS_VAR) != IS_CONST && Z_TYPE(tmp) != IS_UNDEF) {
+                       zend_string_release(Z_STR(tmp));
+               }
+               zval_ptr_dtor_nogc(free_op1);
+
+               if (opline->extended_value & ZEND_ISSET) {
+                       ZVAL_BOOL(EX_VAR(opline->result.var),
+                               value && Z_TYPE_P(value) > IS_NULL &&
+                           (!Z_ISREF_P(value) || Z_TYPE_P(Z_REFVAL_P(value)) != IS_NULL));
+               } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+                       ZVAL_BOOL(EX_VAR(opline->result.var),
+                               !value || !i_zend_is_true(value TSRMLS_CC));
+               }
+
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
+       }
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_SPEC_TMPVAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
@@ -43618,6 +38551,21 @@ static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_TMPVAR_CV_HANDLER(ZEND_O
        ZEND_VM_NEXT_OPCODE();
 }
 
+static int ZEND_FASTCALL  ZEND_CASE_SPEC_TMPVAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *result = EX_VAR(opline->result.var);
+
+       SAVE_OPLINE();
+       fast_equal_function(result,
+                _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
+                _get_zval_ptr_cv_BP_VAR_R(execute_data, opline->op2.var TSRMLS_CC) TSRMLS_CC);
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
 static int ZEND_FASTCALL  ZEND_ADD_SPEC_TMPVAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        USE_OPLINE
@@ -43742,6 +38690,22 @@ static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_TMPVAR_TMPVAR_HANDLER(ZE
        ZEND_VM_NEXT_OPCODE();
 }
 
+static int ZEND_FASTCALL  ZEND_CASE_SPEC_TMPVAR_TMPVAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1, free_op2;
+       zval *result = EX_VAR(opline->result.var);
+
+       SAVE_OPLINE();
+       fast_equal_function(result,
+                _get_zval_ptr_var(opline->op1.var, execute_data, &free_op1),
+                _get_zval_ptr_var(opline->op2.var, execute_data, &free_op2) TSRMLS_CC);
+
+       zval_ptr_dtor_nogc(free_op2);
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
 static int ZEND_FASTCALL ZEND_NULL_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        zend_error_noreturn(E_ERROR, "Invalid opcode %d/%d/%d.", OPLINE->opcode, OPLINE->op1_type, OPLINE->op2_type);
@@ -44953,28 +39917,28 @@ void zend_init_opcodes_handlers(void)
        ZEND_JMPNZ_EX_SPEC_CV_HANDLER,
        ZEND_JMPNZ_EX_SPEC_CV_HANDLER,
        ZEND_CASE_SPEC_CONST_CONST_HANDLER,
-       ZEND_CASE_SPEC_CONST_TMP_HANDLER,
-       ZEND_CASE_SPEC_CONST_VAR_HANDLER,
+       ZEND_CASE_SPEC_CONST_TMPVAR_HANDLER,
+       ZEND_CASE_SPEC_CONST_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_CASE_SPEC_CONST_CV_HANDLER,
-       ZEND_CASE_SPEC_TMP_CONST_HANDLER,
-       ZEND_CASE_SPEC_TMP_TMP_HANDLER,
-       ZEND_CASE_SPEC_TMP_VAR_HANDLER,
+       ZEND_CASE_SPEC_TMPVAR_CONST_HANDLER,
+       ZEND_CASE_SPEC_TMPVAR_TMPVAR_HANDLER,
+       ZEND_CASE_SPEC_TMPVAR_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_CASE_SPEC_TMP_CV_HANDLER,
-       ZEND_CASE_SPEC_VAR_CONST_HANDLER,
-       ZEND_CASE_SPEC_VAR_TMP_HANDLER,
-       ZEND_CASE_SPEC_VAR_VAR_HANDLER,
+       ZEND_CASE_SPEC_TMPVAR_CV_HANDLER,
+       ZEND_CASE_SPEC_TMPVAR_CONST_HANDLER,
+       ZEND_CASE_SPEC_TMPVAR_TMPVAR_HANDLER,
+       ZEND_CASE_SPEC_TMPVAR_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_CASE_SPEC_VAR_CV_HANDLER,
+       ZEND_CASE_SPEC_TMPVAR_CV_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_CASE_SPEC_CV_CONST_HANDLER,
-       ZEND_CASE_SPEC_CV_TMP_HANDLER,
-       ZEND_CASE_SPEC_CV_VAR_HANDLER,
+       ZEND_CASE_SPEC_CV_TMPVAR_HANDLER,
+       ZEND_CASE_SPEC_CV_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_CASE_SPEC_CV_CV_HANDLER,
        ZEND_NULL_HANDLER,
@@ -45057,16 +40021,16 @@ void zend_init_opcodes_handlers(void)
        ZEND_BOOL_SPEC_CONST_HANDLER,
        ZEND_BOOL_SPEC_CONST_HANDLER,
        ZEND_BOOL_SPEC_CONST_HANDLER,
-       ZEND_BOOL_SPEC_TMP_HANDLER,
-       ZEND_BOOL_SPEC_TMP_HANDLER,
-       ZEND_BOOL_SPEC_TMP_HANDLER,
-       ZEND_BOOL_SPEC_TMP_HANDLER,
-       ZEND_BOOL_SPEC_TMP_HANDLER,
-       ZEND_BOOL_SPEC_VAR_HANDLER,
-       ZEND_BOOL_SPEC_VAR_HANDLER,
-       ZEND_BOOL_SPEC_VAR_HANDLER,
-       ZEND_BOOL_SPEC_VAR_HANDLER,
-       ZEND_BOOL_SPEC_VAR_HANDLER,
+       ZEND_BOOL_SPEC_TMPVAR_HANDLER,
+       ZEND_BOOL_SPEC_TMPVAR_HANDLER,
+       ZEND_BOOL_SPEC_TMPVAR_HANDLER,
+       ZEND_BOOL_SPEC_TMPVAR_HANDLER,
+       ZEND_BOOL_SPEC_TMPVAR_HANDLER,
+       ZEND_BOOL_SPEC_TMPVAR_HANDLER,
+       ZEND_BOOL_SPEC_TMPVAR_HANDLER,
+       ZEND_BOOL_SPEC_TMPVAR_HANDLER,
+       ZEND_BOOL_SPEC_TMPVAR_HANDLER,
+       ZEND_BOOL_SPEC_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
@@ -45158,8 +40122,8 @@ void zend_init_opcodes_handlers(void)
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_ADD_VAR_SPEC_TMP_TMP_HANDLER,
-       ZEND_ADD_VAR_SPEC_TMP_VAR_HANDLER,
+       ZEND_ADD_VAR_SPEC_TMP_TMPVAR_HANDLER,
+       ZEND_ADD_VAR_SPEC_TMP_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_ADD_VAR_SPEC_TMP_CV_HANDLER,
        ZEND_NULL_HANDLER,
@@ -45168,8 +40132,8 @@ void zend_init_opcodes_handlers(void)
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_ADD_VAR_SPEC_UNUSED_TMP_HANDLER,
-       ZEND_ADD_VAR_SPEC_UNUSED_VAR_HANDLER,
+       ZEND_ADD_VAR_SPEC_UNUSED_TMPVAR_HANDLER,
+       ZEND_ADD_VAR_SPEC_UNUSED_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_ADD_VAR_SPEC_UNUSED_CV_HANDLER,
        ZEND_NULL_HANDLER,
@@ -45528,43 +40492,43 @@ void zend_init_opcodes_handlers(void)
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_INIT_ARRAY_SPEC_CONST_CONST_HANDLER,
-       ZEND_INIT_ARRAY_SPEC_CONST_TMP_HANDLER,
-       ZEND_INIT_ARRAY_SPEC_CONST_VAR_HANDLER,
+       ZEND_INIT_ARRAY_SPEC_CONST_TMPVAR_HANDLER,
+       ZEND_INIT_ARRAY_SPEC_CONST_TMPVAR_HANDLER,
        ZEND_INIT_ARRAY_SPEC_CONST_UNUSED_HANDLER,
        ZEND_INIT_ARRAY_SPEC_CONST_CV_HANDLER,
        ZEND_INIT_ARRAY_SPEC_TMP_CONST_HANDLER,
-       ZEND_INIT_ARRAY_SPEC_TMP_TMP_HANDLER,
-       ZEND_INIT_ARRAY_SPEC_TMP_VAR_HANDLER,
+       ZEND_INIT_ARRAY_SPEC_TMP_TMPVAR_HANDLER,
+       ZEND_INIT_ARRAY_SPEC_TMP_TMPVAR_HANDLER,
        ZEND_INIT_ARRAY_SPEC_TMP_UNUSED_HANDLER,
        ZEND_INIT_ARRAY_SPEC_TMP_CV_HANDLER,
        ZEND_INIT_ARRAY_SPEC_VAR_CONST_HANDLER,
-       ZEND_INIT_ARRAY_SPEC_VAR_TMP_HANDLER,
-       ZEND_INIT_ARRAY_SPEC_VAR_VAR_HANDLER,
+       ZEND_INIT_ARRAY_SPEC_VAR_TMPVAR_HANDLER,
+       ZEND_INIT_ARRAY_SPEC_VAR_TMPVAR_HANDLER,
        ZEND_INIT_ARRAY_SPEC_VAR_UNUSED_HANDLER,
        ZEND_INIT_ARRAY_SPEC_VAR_CV_HANDLER,
        ZEND_INIT_ARRAY_SPEC_UNUSED_CONST_HANDLER,
-       ZEND_INIT_ARRAY_SPEC_UNUSED_TMP_HANDLER,
-       ZEND_INIT_ARRAY_SPEC_UNUSED_VAR_HANDLER,
+       ZEND_INIT_ARRAY_SPEC_UNUSED_TMPVAR_HANDLER,
+       ZEND_INIT_ARRAY_SPEC_UNUSED_TMPVAR_HANDLER,
        ZEND_INIT_ARRAY_SPEC_UNUSED_UNUSED_HANDLER,
        ZEND_INIT_ARRAY_SPEC_UNUSED_CV_HANDLER,
        ZEND_INIT_ARRAY_SPEC_CV_CONST_HANDLER,
-       ZEND_INIT_ARRAY_SPEC_CV_TMP_HANDLER,
-       ZEND_INIT_ARRAY_SPEC_CV_VAR_HANDLER,
+       ZEND_INIT_ARRAY_SPEC_CV_TMPVAR_HANDLER,
+       ZEND_INIT_ARRAY_SPEC_CV_TMPVAR_HANDLER,
        ZEND_INIT_ARRAY_SPEC_CV_UNUSED_HANDLER,
        ZEND_INIT_ARRAY_SPEC_CV_CV_HANDLER,
        ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_CONST_HANDLER,
-       ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_TMP_HANDLER,
-       ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_VAR_HANDLER,
+       ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_TMPVAR_HANDLER,
+       ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_TMPVAR_HANDLER,
        ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_UNUSED_HANDLER,
        ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_CV_HANDLER,
        ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_CONST_HANDLER,
-       ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_TMP_HANDLER,
-       ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_VAR_HANDLER,
+       ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_TMPVAR_HANDLER,
+       ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_TMPVAR_HANDLER,
        ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_UNUSED_HANDLER,
        ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_CV_HANDLER,
        ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_CONST_HANDLER,
-       ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_TMP_HANDLER,
-       ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_VAR_HANDLER,
+       ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_TMPVAR_HANDLER,
+       ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_TMPVAR_HANDLER,
        ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_UNUSED_HANDLER,
        ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_CV_HANDLER,
        ZEND_NULL_HANDLER,
@@ -45573,8 +40537,8 @@ void zend_init_opcodes_handlers(void)
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CONST_HANDLER,
-       ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_TMP_HANDLER,
-       ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_VAR_HANDLER,
+       ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_TMPVAR_HANDLER,
+       ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_TMPVAR_HANDLER,
        ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_UNUSED_HANDLER,
        ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CV_HANDLER,
        ZEND_INCLUDE_OR_EVAL_SPEC_CONST_HANDLER,
@@ -45582,16 +40546,16 @@ void zend_init_opcodes_handlers(void)
        ZEND_INCLUDE_OR_EVAL_SPEC_CONST_HANDLER,
        ZEND_INCLUDE_OR_EVAL_SPEC_CONST_HANDLER,
        ZEND_INCLUDE_OR_EVAL_SPEC_CONST_HANDLER,
-       ZEND_INCLUDE_OR_EVAL_SPEC_TMP_HANDLER,
-       ZEND_INCLUDE_OR_EVAL_SPEC_TMP_HANDLER,
-       ZEND_INCLUDE_OR_EVAL_SPEC_TMP_HANDLER,
-       ZEND_INCLUDE_OR_EVAL_SPEC_TMP_HANDLER,
-       ZEND_INCLUDE_OR_EVAL_SPEC_TMP_HANDLER,
-       ZEND_INCLUDE_OR_EVAL_SPEC_VAR_HANDLER,
-       ZEND_INCLUDE_OR_EVAL_SPEC_VAR_HANDLER,
-       ZEND_INCLUDE_OR_EVAL_SPEC_VAR_HANDLER,
-       ZEND_INCLUDE_OR_EVAL_SPEC_VAR_HANDLER,
-       ZEND_INCLUDE_OR_EVAL_SPEC_VAR_HANDLER,
+       ZEND_INCLUDE_OR_EVAL_SPEC_TMPVAR_HANDLER,
+       ZEND_INCLUDE_OR_EVAL_SPEC_TMPVAR_HANDLER,
+       ZEND_INCLUDE_OR_EVAL_SPEC_TMPVAR_HANDLER,
+       ZEND_INCLUDE_OR_EVAL_SPEC_TMPVAR_HANDLER,
+       ZEND_INCLUDE_OR_EVAL_SPEC_TMPVAR_HANDLER,
+       ZEND_INCLUDE_OR_EVAL_SPEC_TMPVAR_HANDLER,
+       ZEND_INCLUDE_OR_EVAL_SPEC_TMPVAR_HANDLER,
+       ZEND_INCLUDE_OR_EVAL_SPEC_TMPVAR_HANDLER,
+       ZEND_INCLUDE_OR_EVAL_SPEC_TMPVAR_HANDLER,
+       ZEND_INCLUDE_OR_EVAL_SPEC_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
@@ -45607,15 +40571,15 @@ void zend_init_opcodes_handlers(void)
        ZEND_UNSET_VAR_SPEC_CONST_VAR_HANDLER,
        ZEND_UNSET_VAR_SPEC_CONST_UNUSED_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_UNSET_VAR_SPEC_TMP_CONST_HANDLER,
+       ZEND_UNSET_VAR_SPEC_TMPVAR_CONST_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_UNSET_VAR_SPEC_TMP_VAR_HANDLER,
-       ZEND_UNSET_VAR_SPEC_TMP_UNUSED_HANDLER,
+       ZEND_UNSET_VAR_SPEC_TMPVAR_VAR_HANDLER,
+       ZEND_UNSET_VAR_SPEC_TMPVAR_UNUSED_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_UNSET_VAR_SPEC_VAR_CONST_HANDLER,
+       ZEND_UNSET_VAR_SPEC_TMPVAR_CONST_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_UNSET_VAR_SPEC_VAR_VAR_HANDLER,
-       ZEND_UNSET_VAR_SPEC_VAR_UNUSED_HANDLER,
+       ZEND_UNSET_VAR_SPEC_TMPVAR_VAR_HANDLER,
+       ZEND_UNSET_VAR_SPEC_TMPVAR_UNUSED_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
@@ -45638,18 +40602,18 @@ void zend_init_opcodes_handlers(void)
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_UNSET_DIM_SPEC_VAR_CONST_HANDLER,
-       ZEND_UNSET_DIM_SPEC_VAR_TMP_HANDLER,
-       ZEND_UNSET_DIM_SPEC_VAR_VAR_HANDLER,
+       ZEND_UNSET_DIM_SPEC_VAR_TMPVAR_HANDLER,
+       ZEND_UNSET_DIM_SPEC_VAR_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_UNSET_DIM_SPEC_VAR_CV_HANDLER,
        ZEND_UNSET_DIM_SPEC_UNUSED_CONST_HANDLER,
-       ZEND_UNSET_DIM_SPEC_UNUSED_TMP_HANDLER,
-       ZEND_UNSET_DIM_SPEC_UNUSED_VAR_HANDLER,
+       ZEND_UNSET_DIM_SPEC_UNUSED_TMPVAR_HANDLER,
+       ZEND_UNSET_DIM_SPEC_UNUSED_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_UNSET_DIM_SPEC_UNUSED_CV_HANDLER,
        ZEND_UNSET_DIM_SPEC_CV_CONST_HANDLER,
-       ZEND_UNSET_DIM_SPEC_CV_TMP_HANDLER,
-       ZEND_UNSET_DIM_SPEC_CV_VAR_HANDLER,
+       ZEND_UNSET_DIM_SPEC_CV_TMPVAR_HANDLER,
+       ZEND_UNSET_DIM_SPEC_CV_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_UNSET_DIM_SPEC_CV_CV_HANDLER,
        ZEND_NULL_HANDLER,
@@ -45663,18 +40627,18 @@ void zend_init_opcodes_handlers(void)
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_UNSET_OBJ_SPEC_VAR_CONST_HANDLER,
-       ZEND_UNSET_OBJ_SPEC_VAR_TMP_HANDLER,
-       ZEND_UNSET_OBJ_SPEC_VAR_VAR_HANDLER,
+       ZEND_UNSET_OBJ_SPEC_VAR_TMPVAR_HANDLER,
+       ZEND_UNSET_OBJ_SPEC_VAR_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_UNSET_OBJ_SPEC_VAR_CV_HANDLER,
        ZEND_UNSET_OBJ_SPEC_UNUSED_CONST_HANDLER,
-       ZEND_UNSET_OBJ_SPEC_UNUSED_TMP_HANDLER,
-       ZEND_UNSET_OBJ_SPEC_UNUSED_VAR_HANDLER,
+       ZEND_UNSET_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
+       ZEND_UNSET_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_UNSET_OBJ_SPEC_UNUSED_CV_HANDLER,
        ZEND_UNSET_OBJ_SPEC_CV_CONST_HANDLER,
-       ZEND_UNSET_OBJ_SPEC_CV_TMP_HANDLER,
-       ZEND_UNSET_OBJ_SPEC_CV_VAR_HANDLER,
+       ZEND_UNSET_OBJ_SPEC_CV_TMPVAR_HANDLER,
+       ZEND_UNSET_OBJ_SPEC_CV_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_UNSET_OBJ_SPEC_CV_CV_HANDLER,
        ZEND_FE_RESET_SPEC_CONST_HANDLER,
@@ -45757,15 +40721,15 @@ void zend_init_opcodes_handlers(void)
        ZEND_FETCH_R_SPEC_CONST_VAR_HANDLER,
        ZEND_FETCH_R_SPEC_CONST_UNUSED_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_FETCH_R_SPEC_TMP_CONST_HANDLER,
+       ZEND_FETCH_R_SPEC_TMPVAR_CONST_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_FETCH_R_SPEC_TMP_VAR_HANDLER,
-       ZEND_FETCH_R_SPEC_TMP_UNUSED_HANDLER,
+       ZEND_FETCH_R_SPEC_TMPVAR_VAR_HANDLER,
+       ZEND_FETCH_R_SPEC_TMPVAR_UNUSED_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_FETCH_R_SPEC_VAR_CONST_HANDLER,
+       ZEND_FETCH_R_SPEC_TMPVAR_CONST_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_FETCH_R_SPEC_VAR_VAR_HANDLER,
-       ZEND_FETCH_R_SPEC_VAR_UNUSED_HANDLER,
+       ZEND_FETCH_R_SPEC_TMPVAR_VAR_HANDLER,
+       ZEND_FETCH_R_SPEC_TMPVAR_UNUSED_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
@@ -45803,28 +40767,28 @@ void zend_init_opcodes_handlers(void)
        ZEND_NULL_HANDLER,
        ZEND_FETCH_DIM_R_SPEC_CV_CV_HANDLER,
        ZEND_FETCH_OBJ_R_SPEC_CONST_CONST_HANDLER,
-       ZEND_FETCH_OBJ_R_SPEC_CONST_TMP_HANDLER,
-       ZEND_FETCH_OBJ_R_SPEC_CONST_VAR_HANDLER,
+       ZEND_FETCH_OBJ_R_SPEC_CONST_TMPVAR_HANDLER,
+       ZEND_FETCH_OBJ_R_SPEC_CONST_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_R_SPEC_CONST_CV_HANDLER,
        ZEND_FETCH_OBJ_R_SPEC_TMP_CONST_HANDLER,
-       ZEND_FETCH_OBJ_R_SPEC_TMP_TMP_HANDLER,
-       ZEND_FETCH_OBJ_R_SPEC_TMP_VAR_HANDLER,
+       ZEND_FETCH_OBJ_R_SPEC_TMP_TMPVAR_HANDLER,
+       ZEND_FETCH_OBJ_R_SPEC_TMP_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_R_SPEC_TMP_CV_HANDLER,
        ZEND_FETCH_OBJ_R_SPEC_VAR_CONST_HANDLER,
-       ZEND_FETCH_OBJ_R_SPEC_VAR_TMP_HANDLER,
-       ZEND_FETCH_OBJ_R_SPEC_VAR_VAR_HANDLER,
+       ZEND_FETCH_OBJ_R_SPEC_VAR_TMPVAR_HANDLER,
+       ZEND_FETCH_OBJ_R_SPEC_VAR_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_R_SPEC_VAR_CV_HANDLER,
        ZEND_FETCH_OBJ_R_SPEC_UNUSED_CONST_HANDLER,
-       ZEND_FETCH_OBJ_R_SPEC_UNUSED_TMP_HANDLER,
-       ZEND_FETCH_OBJ_R_SPEC_UNUSED_VAR_HANDLER,
+       ZEND_FETCH_OBJ_R_SPEC_UNUSED_TMPVAR_HANDLER,
+       ZEND_FETCH_OBJ_R_SPEC_UNUSED_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_R_SPEC_UNUSED_CV_HANDLER,
        ZEND_FETCH_OBJ_R_SPEC_CV_CONST_HANDLER,
-       ZEND_FETCH_OBJ_R_SPEC_CV_TMP_HANDLER,
-       ZEND_FETCH_OBJ_R_SPEC_CV_VAR_HANDLER,
+       ZEND_FETCH_OBJ_R_SPEC_CV_TMPVAR_HANDLER,
+       ZEND_FETCH_OBJ_R_SPEC_CV_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_R_SPEC_CV_CV_HANDLER,
        ZEND_FETCH_W_SPEC_CONST_CONST_HANDLER,
@@ -45832,15 +40796,15 @@ void zend_init_opcodes_handlers(void)
        ZEND_FETCH_W_SPEC_CONST_VAR_HANDLER,
        ZEND_FETCH_W_SPEC_CONST_UNUSED_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_FETCH_W_SPEC_TMP_CONST_HANDLER,
+       ZEND_FETCH_W_SPEC_TMPVAR_CONST_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_FETCH_W_SPEC_TMP_VAR_HANDLER,
-       ZEND_FETCH_W_SPEC_TMP_UNUSED_HANDLER,
+       ZEND_FETCH_W_SPEC_TMPVAR_VAR_HANDLER,
+       ZEND_FETCH_W_SPEC_TMPVAR_UNUSED_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_FETCH_W_SPEC_VAR_CONST_HANDLER,
+       ZEND_FETCH_W_SPEC_TMPVAR_CONST_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_FETCH_W_SPEC_VAR_VAR_HANDLER,
-       ZEND_FETCH_W_SPEC_VAR_UNUSED_HANDLER,
+       ZEND_FETCH_W_SPEC_TMPVAR_VAR_HANDLER,
+       ZEND_FETCH_W_SPEC_TMPVAR_UNUSED_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
@@ -45888,18 +40852,18 @@ void zend_init_opcodes_handlers(void)
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_W_SPEC_VAR_CONST_HANDLER,
-       ZEND_FETCH_OBJ_W_SPEC_VAR_TMP_HANDLER,
-       ZEND_FETCH_OBJ_W_SPEC_VAR_VAR_HANDLER,
+       ZEND_FETCH_OBJ_W_SPEC_VAR_TMPVAR_HANDLER,
+       ZEND_FETCH_OBJ_W_SPEC_VAR_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_W_SPEC_VAR_CV_HANDLER,
        ZEND_FETCH_OBJ_W_SPEC_UNUSED_CONST_HANDLER,
-       ZEND_FETCH_OBJ_W_SPEC_UNUSED_TMP_HANDLER,
-       ZEND_FETCH_OBJ_W_SPEC_UNUSED_VAR_HANDLER,
+       ZEND_FETCH_OBJ_W_SPEC_UNUSED_TMPVAR_HANDLER,
+       ZEND_FETCH_OBJ_W_SPEC_UNUSED_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_W_SPEC_UNUSED_CV_HANDLER,
        ZEND_FETCH_OBJ_W_SPEC_CV_CONST_HANDLER,
-       ZEND_FETCH_OBJ_W_SPEC_CV_TMP_HANDLER,
-       ZEND_FETCH_OBJ_W_SPEC_CV_VAR_HANDLER,
+       ZEND_FETCH_OBJ_W_SPEC_CV_TMPVAR_HANDLER,
+       ZEND_FETCH_OBJ_W_SPEC_CV_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_W_SPEC_CV_CV_HANDLER,
        ZEND_FETCH_RW_SPEC_CONST_CONST_HANDLER,
@@ -45907,15 +40871,15 @@ void zend_init_opcodes_handlers(void)
        ZEND_FETCH_RW_SPEC_CONST_VAR_HANDLER,
        ZEND_FETCH_RW_SPEC_CONST_UNUSED_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_FETCH_RW_SPEC_TMP_CONST_HANDLER,
+       ZEND_FETCH_RW_SPEC_TMPVAR_CONST_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_FETCH_RW_SPEC_TMP_VAR_HANDLER,
-       ZEND_FETCH_RW_SPEC_TMP_UNUSED_HANDLER,
+       ZEND_FETCH_RW_SPEC_TMPVAR_VAR_HANDLER,
+       ZEND_FETCH_RW_SPEC_TMPVAR_UNUSED_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_FETCH_RW_SPEC_VAR_CONST_HANDLER,
+       ZEND_FETCH_RW_SPEC_TMPVAR_CONST_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_FETCH_RW_SPEC_VAR_VAR_HANDLER,
-       ZEND_FETCH_RW_SPEC_VAR_UNUSED_HANDLER,
+       ZEND_FETCH_RW_SPEC_TMPVAR_VAR_HANDLER,
+       ZEND_FETCH_RW_SPEC_TMPVAR_UNUSED_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
@@ -45963,18 +40927,18 @@ void zend_init_opcodes_handlers(void)
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_RW_SPEC_VAR_CONST_HANDLER,
-       ZEND_FETCH_OBJ_RW_SPEC_VAR_TMP_HANDLER,
-       ZEND_FETCH_OBJ_RW_SPEC_VAR_VAR_HANDLER,
+       ZEND_FETCH_OBJ_RW_SPEC_VAR_TMPVAR_HANDLER,
+       ZEND_FETCH_OBJ_RW_SPEC_VAR_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_RW_SPEC_VAR_CV_HANDLER,
        ZEND_FETCH_OBJ_RW_SPEC_UNUSED_CONST_HANDLER,
-       ZEND_FETCH_OBJ_RW_SPEC_UNUSED_TMP_HANDLER,
-       ZEND_FETCH_OBJ_RW_SPEC_UNUSED_VAR_HANDLER,
+       ZEND_FETCH_OBJ_RW_SPEC_UNUSED_TMPVAR_HANDLER,
+       ZEND_FETCH_OBJ_RW_SPEC_UNUSED_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_RW_SPEC_UNUSED_CV_HANDLER,
        ZEND_FETCH_OBJ_RW_SPEC_CV_CONST_HANDLER,
-       ZEND_FETCH_OBJ_RW_SPEC_CV_TMP_HANDLER,
-       ZEND_FETCH_OBJ_RW_SPEC_CV_VAR_HANDLER,
+       ZEND_FETCH_OBJ_RW_SPEC_CV_TMPVAR_HANDLER,
+       ZEND_FETCH_OBJ_RW_SPEC_CV_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_RW_SPEC_CV_CV_HANDLER,
        ZEND_FETCH_IS_SPEC_CONST_CONST_HANDLER,
@@ -45982,15 +40946,15 @@ void zend_init_opcodes_handlers(void)
        ZEND_FETCH_IS_SPEC_CONST_VAR_HANDLER,
        ZEND_FETCH_IS_SPEC_CONST_UNUSED_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_FETCH_IS_SPEC_TMP_CONST_HANDLER,
+       ZEND_FETCH_IS_SPEC_TMPVAR_CONST_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_FETCH_IS_SPEC_TMP_VAR_HANDLER,
-       ZEND_FETCH_IS_SPEC_TMP_UNUSED_HANDLER,
+       ZEND_FETCH_IS_SPEC_TMPVAR_VAR_HANDLER,
+       ZEND_FETCH_IS_SPEC_TMPVAR_UNUSED_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_FETCH_IS_SPEC_VAR_CONST_HANDLER,
+       ZEND_FETCH_IS_SPEC_TMPVAR_CONST_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_FETCH_IS_SPEC_VAR_VAR_HANDLER,
-       ZEND_FETCH_IS_SPEC_VAR_UNUSED_HANDLER,
+       ZEND_FETCH_IS_SPEC_TMPVAR_VAR_HANDLER,
+       ZEND_FETCH_IS_SPEC_TMPVAR_UNUSED_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
@@ -46028,28 +40992,28 @@ void zend_init_opcodes_handlers(void)
        ZEND_NULL_HANDLER,
        ZEND_FETCH_DIM_IS_SPEC_CV_CV_HANDLER,
        ZEND_FETCH_OBJ_IS_SPEC_CONST_CONST_HANDLER,
-       ZEND_FETCH_OBJ_IS_SPEC_CONST_TMP_HANDLER,
-       ZEND_FETCH_OBJ_IS_SPEC_CONST_VAR_HANDLER,
+       ZEND_FETCH_OBJ_IS_SPEC_CONST_TMPVAR_HANDLER,
+       ZEND_FETCH_OBJ_IS_SPEC_CONST_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_IS_SPEC_CONST_CV_HANDLER,
        ZEND_FETCH_OBJ_IS_SPEC_TMP_CONST_HANDLER,
-       ZEND_FETCH_OBJ_IS_SPEC_TMP_TMP_HANDLER,
-       ZEND_FETCH_OBJ_IS_SPEC_TMP_VAR_HANDLER,
+       ZEND_FETCH_OBJ_IS_SPEC_TMP_TMPVAR_HANDLER,
+       ZEND_FETCH_OBJ_IS_SPEC_TMP_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_IS_SPEC_TMP_CV_HANDLER,
        ZEND_FETCH_OBJ_IS_SPEC_VAR_CONST_HANDLER,
-       ZEND_FETCH_OBJ_IS_SPEC_VAR_TMP_HANDLER,
-       ZEND_FETCH_OBJ_IS_SPEC_VAR_VAR_HANDLER,
+       ZEND_FETCH_OBJ_IS_SPEC_VAR_TMPVAR_HANDLER,
+       ZEND_FETCH_OBJ_IS_SPEC_VAR_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_IS_SPEC_VAR_CV_HANDLER,
        ZEND_FETCH_OBJ_IS_SPEC_UNUSED_CONST_HANDLER,
-       ZEND_FETCH_OBJ_IS_SPEC_UNUSED_TMP_HANDLER,
-       ZEND_FETCH_OBJ_IS_SPEC_UNUSED_VAR_HANDLER,
+       ZEND_FETCH_OBJ_IS_SPEC_UNUSED_TMPVAR_HANDLER,
+       ZEND_FETCH_OBJ_IS_SPEC_UNUSED_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_IS_SPEC_UNUSED_CV_HANDLER,
        ZEND_FETCH_OBJ_IS_SPEC_CV_CONST_HANDLER,
-       ZEND_FETCH_OBJ_IS_SPEC_CV_TMP_HANDLER,
-       ZEND_FETCH_OBJ_IS_SPEC_CV_VAR_HANDLER,
+       ZEND_FETCH_OBJ_IS_SPEC_CV_TMPVAR_HANDLER,
+       ZEND_FETCH_OBJ_IS_SPEC_CV_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_IS_SPEC_CV_CV_HANDLER,
        ZEND_FETCH_FUNC_ARG_SPEC_CONST_CONST_HANDLER,
@@ -46057,15 +41021,15 @@ void zend_init_opcodes_handlers(void)
        ZEND_FETCH_FUNC_ARG_SPEC_CONST_VAR_HANDLER,
        ZEND_FETCH_FUNC_ARG_SPEC_CONST_UNUSED_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_FETCH_FUNC_ARG_SPEC_TMP_CONST_HANDLER,
+       ZEND_FETCH_FUNC_ARG_SPEC_TMPVAR_CONST_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_FETCH_FUNC_ARG_SPEC_TMP_VAR_HANDLER,
-       ZEND_FETCH_FUNC_ARG_SPEC_TMP_UNUSED_HANDLER,
+       ZEND_FETCH_FUNC_ARG_SPEC_TMPVAR_VAR_HANDLER,
+       ZEND_FETCH_FUNC_ARG_SPEC_TMPVAR_UNUSED_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_FETCH_FUNC_ARG_SPEC_VAR_CONST_HANDLER,
+       ZEND_FETCH_FUNC_ARG_SPEC_TMPVAR_CONST_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_FETCH_FUNC_ARG_SPEC_VAR_VAR_HANDLER,
-       ZEND_FETCH_FUNC_ARG_SPEC_VAR_UNUSED_HANDLER,
+       ZEND_FETCH_FUNC_ARG_SPEC_TMPVAR_VAR_HANDLER,
+       ZEND_FETCH_FUNC_ARG_SPEC_TMPVAR_UNUSED_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
@@ -46103,28 +41067,28 @@ void zend_init_opcodes_handlers(void)
        ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_UNUSED_HANDLER,
        ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_CV_HANDLER,
        ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CONST_CONST_HANDLER,
-       ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CONST_TMP_HANDLER,
-       ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CONST_VAR_HANDLER,
+       ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CONST_TMPVAR_HANDLER,
+       ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CONST_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CONST_CV_HANDLER,
        ZEND_FETCH_OBJ_FUNC_ARG_SPEC_TMP_CONST_HANDLER,
-       ZEND_FETCH_OBJ_FUNC_ARG_SPEC_TMP_TMP_HANDLER,
-       ZEND_FETCH_OBJ_FUNC_ARG_SPEC_TMP_VAR_HANDLER,
+       ZEND_FETCH_OBJ_FUNC_ARG_SPEC_TMP_TMPVAR_HANDLER,
+       ZEND_FETCH_OBJ_FUNC_ARG_SPEC_TMP_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_FUNC_ARG_SPEC_TMP_CV_HANDLER,
        ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_CONST_HANDLER,
-       ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_TMP_HANDLER,
-       ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_VAR_HANDLER,
+       ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_TMPVAR_HANDLER,
+       ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_CV_HANDLER,
        ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_CONST_HANDLER,
-       ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_TMP_HANDLER,
-       ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_VAR_HANDLER,
+       ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_TMPVAR_HANDLER,
+       ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_CV_HANDLER,
        ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_CONST_HANDLER,
-       ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_TMP_HANDLER,
-       ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_VAR_HANDLER,
+       ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_TMPVAR_HANDLER,
+       ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_CV_HANDLER,
        ZEND_FETCH_UNSET_SPEC_CONST_CONST_HANDLER,
@@ -46132,15 +41096,15 @@ void zend_init_opcodes_handlers(void)
        ZEND_FETCH_UNSET_SPEC_CONST_VAR_HANDLER,
        ZEND_FETCH_UNSET_SPEC_CONST_UNUSED_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_FETCH_UNSET_SPEC_TMP_CONST_HANDLER,
+       ZEND_FETCH_UNSET_SPEC_TMPVAR_CONST_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_FETCH_UNSET_SPEC_TMP_VAR_HANDLER,
-       ZEND_FETCH_UNSET_SPEC_TMP_UNUSED_HANDLER,
+       ZEND_FETCH_UNSET_SPEC_TMPVAR_VAR_HANDLER,
+       ZEND_FETCH_UNSET_SPEC_TMPVAR_UNUSED_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_FETCH_UNSET_SPEC_VAR_CONST_HANDLER,
+       ZEND_FETCH_UNSET_SPEC_TMPVAR_CONST_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_FETCH_UNSET_SPEC_VAR_VAR_HANDLER,
-       ZEND_FETCH_UNSET_SPEC_VAR_UNUSED_HANDLER,
+       ZEND_FETCH_UNSET_SPEC_TMPVAR_VAR_HANDLER,
+       ZEND_FETCH_UNSET_SPEC_TMPVAR_UNUSED_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
@@ -46188,18 +41152,18 @@ void zend_init_opcodes_handlers(void)
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_UNSET_SPEC_VAR_CONST_HANDLER,
-       ZEND_FETCH_OBJ_UNSET_SPEC_VAR_TMP_HANDLER,
-       ZEND_FETCH_OBJ_UNSET_SPEC_VAR_VAR_HANDLER,
+       ZEND_FETCH_OBJ_UNSET_SPEC_VAR_TMPVAR_HANDLER,
+       ZEND_FETCH_OBJ_UNSET_SPEC_VAR_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_UNSET_SPEC_VAR_CV_HANDLER,
        ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_CONST_HANDLER,
-       ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_TMP_HANDLER,
-       ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_VAR_HANDLER,
+       ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_TMPVAR_HANDLER,
+       ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_CV_HANDLER,
        ZEND_FETCH_OBJ_UNSET_SPEC_CV_CONST_HANDLER,
-       ZEND_FETCH_OBJ_UNSET_SPEC_CV_TMP_HANDLER,
-       ZEND_FETCH_OBJ_UNSET_SPEC_CV_VAR_HANDLER,
+       ZEND_FETCH_OBJ_UNSET_SPEC_CV_TMPVAR_HANDLER,
+       ZEND_FETCH_OBJ_UNSET_SPEC_CV_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_FETCH_OBJ_UNSET_SPEC_CV_CV_HANDLER,
        ZEND_FETCH_LIST_SPEC_CONST_CONST_HANDLER,
@@ -46558,28 +41522,28 @@ void zend_init_opcodes_handlers(void)
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_INIT_METHOD_CALL_SPEC_TMP_CONST_HANDLER,
-       ZEND_INIT_METHOD_CALL_SPEC_TMP_TMP_HANDLER,
-       ZEND_INIT_METHOD_CALL_SPEC_TMP_VAR_HANDLER,
+       ZEND_INIT_METHOD_CALL_SPEC_TMP_TMPVAR_HANDLER,
+       ZEND_INIT_METHOD_CALL_SPEC_TMP_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_INIT_METHOD_CALL_SPEC_TMP_CV_HANDLER,
        ZEND_INIT_METHOD_CALL_SPEC_VAR_CONST_HANDLER,
-       ZEND_INIT_METHOD_CALL_SPEC_VAR_TMP_HANDLER,
-       ZEND_INIT_METHOD_CALL_SPEC_VAR_VAR_HANDLER,
+       ZEND_INIT_METHOD_CALL_SPEC_VAR_TMPVAR_HANDLER,
+       ZEND_INIT_METHOD_CALL_SPEC_VAR_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_INIT_METHOD_CALL_SPEC_VAR_CV_HANDLER,
        ZEND_INIT_METHOD_CALL_SPEC_UNUSED_CONST_HANDLER,
-       ZEND_INIT_METHOD_CALL_SPEC_UNUSED_TMP_HANDLER,
-       ZEND_INIT_METHOD_CALL_SPEC_UNUSED_VAR_HANDLER,
+       ZEND_INIT_METHOD_CALL_SPEC_UNUSED_TMPVAR_HANDLER,
+       ZEND_INIT_METHOD_CALL_SPEC_UNUSED_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_INIT_METHOD_CALL_SPEC_UNUSED_CV_HANDLER,
        ZEND_INIT_METHOD_CALL_SPEC_CV_CONST_HANDLER,
-       ZEND_INIT_METHOD_CALL_SPEC_CV_TMP_HANDLER,
-       ZEND_INIT_METHOD_CALL_SPEC_CV_VAR_HANDLER,
+       ZEND_INIT_METHOD_CALL_SPEC_CV_TMPVAR_HANDLER,
+       ZEND_INIT_METHOD_CALL_SPEC_CV_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_INIT_METHOD_CALL_SPEC_CV_CV_HANDLER,
        ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_CONST_HANDLER,
-       ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_TMP_HANDLER,
-       ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_VAR_HANDLER,
+       ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_TMPVAR_HANDLER,
+       ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_TMPVAR_HANDLER,
        ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_UNUSED_HANDLER,
        ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_CV_HANDLER,
        ZEND_NULL_HANDLER,
@@ -46588,8 +41552,8 @@ void zend_init_opcodes_handlers(void)
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_CONST_HANDLER,
-       ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_TMP_HANDLER,
-       ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_VAR_HANDLER,
+       ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_TMPVAR_HANDLER,
+       ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_TMPVAR_HANDLER,
        ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_UNUSED_HANDLER,
        ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_CV_HANDLER,
        ZEND_NULL_HANDLER,
@@ -46607,15 +41571,15 @@ void zend_init_opcodes_handlers(void)
        ZEND_ISSET_ISEMPTY_VAR_SPEC_CONST_VAR_HANDLER,
        ZEND_ISSET_ISEMPTY_VAR_SPEC_CONST_UNUSED_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_ISSET_ISEMPTY_VAR_SPEC_TMP_CONST_HANDLER,
+       ZEND_ISSET_ISEMPTY_VAR_SPEC_TMPVAR_CONST_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_ISSET_ISEMPTY_VAR_SPEC_TMP_VAR_HANDLER,
-       ZEND_ISSET_ISEMPTY_VAR_SPEC_TMP_UNUSED_HANDLER,
+       ZEND_ISSET_ISEMPTY_VAR_SPEC_TMPVAR_VAR_HANDLER,
+       ZEND_ISSET_ISEMPTY_VAR_SPEC_TMPVAR_UNUSED_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_ISSET_ISEMPTY_VAR_SPEC_VAR_CONST_HANDLER,
+       ZEND_ISSET_ISEMPTY_VAR_SPEC_TMPVAR_CONST_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_ISSET_ISEMPTY_VAR_SPEC_VAR_VAR_HANDLER,
-       ZEND_ISSET_ISEMPTY_VAR_SPEC_VAR_UNUSED_HANDLER,
+       ZEND_ISSET_ISEMPTY_VAR_SPEC_TMPVAR_VAR_HANDLER,
+       ZEND_ISSET_ISEMPTY_VAR_SPEC_TMPVAR_UNUSED_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
@@ -46628,28 +41592,28 @@ void zend_init_opcodes_handlers(void)
        ZEND_ISSET_ISEMPTY_VAR_SPEC_CV_UNUSED_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CONST_CONST_HANDLER,
-       ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CONST_TMP_HANDLER,
-       ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CONST_VAR_HANDLER,
+       ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CONST_TMPVAR_HANDLER,
+       ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CONST_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CONST_CV_HANDLER,
        ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_CONST_HANDLER,
-       ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_TMP_HANDLER,
-       ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_VAR_HANDLER,
+       ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_TMPVAR_HANDLER,
+       ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_TMP_CV_HANDLER,
        ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_CONST_HANDLER,
-       ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_TMP_HANDLER,
-       ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_VAR_HANDLER,
+       ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_TMPVAR_HANDLER,
+       ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_VAR_CV_HANDLER,
        ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_CONST_HANDLER,
-       ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_TMP_HANDLER,
-       ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_VAR_HANDLER,
+       ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
+       ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_UNUSED_CV_HANDLER,
        ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_CONST_HANDLER,
-       ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_TMP_HANDLER,
-       ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_VAR_HANDLER,
+       ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_TMPVAR_HANDLER,
+       ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_ISSET_ISEMPTY_DIM_OBJ_SPEC_CV_CV_HANDLER,
        ZEND_SEND_VAL_EX_SPEC_CONST_HANDLER,
@@ -47063,18 +42027,18 @@ void zend_init_opcodes_handlers(void)
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_PRE_INC_OBJ_SPEC_VAR_CONST_HANDLER,
-       ZEND_PRE_INC_OBJ_SPEC_VAR_TMP_HANDLER,
-       ZEND_PRE_INC_OBJ_SPEC_VAR_VAR_HANDLER,
+       ZEND_PRE_INC_OBJ_SPEC_VAR_TMPVAR_HANDLER,
+       ZEND_PRE_INC_OBJ_SPEC_VAR_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_PRE_INC_OBJ_SPEC_VAR_CV_HANDLER,
        ZEND_PRE_INC_OBJ_SPEC_UNUSED_CONST_HANDLER,
-       ZEND_PRE_INC_OBJ_SPEC_UNUSED_TMP_HANDLER,
-       ZEND_PRE_INC_OBJ_SPEC_UNUSED_VAR_HANDLER,
+       ZEND_PRE_INC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
+       ZEND_PRE_INC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_PRE_INC_OBJ_SPEC_UNUSED_CV_HANDLER,
        ZEND_PRE_INC_OBJ_SPEC_CV_CONST_HANDLER,
-       ZEND_PRE_INC_OBJ_SPEC_CV_TMP_HANDLER,
-       ZEND_PRE_INC_OBJ_SPEC_CV_VAR_HANDLER,
+       ZEND_PRE_INC_OBJ_SPEC_CV_TMPVAR_HANDLER,
+       ZEND_PRE_INC_OBJ_SPEC_CV_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_PRE_INC_OBJ_SPEC_CV_CV_HANDLER,
        ZEND_NULL_HANDLER,
@@ -47088,18 +42052,18 @@ void zend_init_opcodes_handlers(void)
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_PRE_DEC_OBJ_SPEC_VAR_CONST_HANDLER,
-       ZEND_PRE_DEC_OBJ_SPEC_VAR_TMP_HANDLER,
-       ZEND_PRE_DEC_OBJ_SPEC_VAR_VAR_HANDLER,
+       ZEND_PRE_DEC_OBJ_SPEC_VAR_TMPVAR_HANDLER,
+       ZEND_PRE_DEC_OBJ_SPEC_VAR_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_PRE_DEC_OBJ_SPEC_VAR_CV_HANDLER,
        ZEND_PRE_DEC_OBJ_SPEC_UNUSED_CONST_HANDLER,
-       ZEND_PRE_DEC_OBJ_SPEC_UNUSED_TMP_HANDLER,
-       ZEND_PRE_DEC_OBJ_SPEC_UNUSED_VAR_HANDLER,
+       ZEND_PRE_DEC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
+       ZEND_PRE_DEC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_PRE_DEC_OBJ_SPEC_UNUSED_CV_HANDLER,
        ZEND_PRE_DEC_OBJ_SPEC_CV_CONST_HANDLER,
-       ZEND_PRE_DEC_OBJ_SPEC_CV_TMP_HANDLER,
-       ZEND_PRE_DEC_OBJ_SPEC_CV_VAR_HANDLER,
+       ZEND_PRE_DEC_OBJ_SPEC_CV_TMPVAR_HANDLER,
+       ZEND_PRE_DEC_OBJ_SPEC_CV_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_PRE_DEC_OBJ_SPEC_CV_CV_HANDLER,
        ZEND_NULL_HANDLER,
@@ -47113,18 +42077,18 @@ void zend_init_opcodes_handlers(void)
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_POST_INC_OBJ_SPEC_VAR_CONST_HANDLER,
-       ZEND_POST_INC_OBJ_SPEC_VAR_TMP_HANDLER,
-       ZEND_POST_INC_OBJ_SPEC_VAR_VAR_HANDLER,
+       ZEND_POST_INC_OBJ_SPEC_VAR_TMPVAR_HANDLER,
+       ZEND_POST_INC_OBJ_SPEC_VAR_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_POST_INC_OBJ_SPEC_VAR_CV_HANDLER,
        ZEND_POST_INC_OBJ_SPEC_UNUSED_CONST_HANDLER,
-       ZEND_POST_INC_OBJ_SPEC_UNUSED_TMP_HANDLER,
-       ZEND_POST_INC_OBJ_SPEC_UNUSED_VAR_HANDLER,
+       ZEND_POST_INC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
+       ZEND_POST_INC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_POST_INC_OBJ_SPEC_UNUSED_CV_HANDLER,
        ZEND_POST_INC_OBJ_SPEC_CV_CONST_HANDLER,
-       ZEND_POST_INC_OBJ_SPEC_CV_TMP_HANDLER,
-       ZEND_POST_INC_OBJ_SPEC_CV_VAR_HANDLER,
+       ZEND_POST_INC_OBJ_SPEC_CV_TMPVAR_HANDLER,
+       ZEND_POST_INC_OBJ_SPEC_CV_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_POST_INC_OBJ_SPEC_CV_CV_HANDLER,
        ZEND_NULL_HANDLER,
@@ -47138,18 +42102,18 @@ void zend_init_opcodes_handlers(void)
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_POST_DEC_OBJ_SPEC_VAR_CONST_HANDLER,
-       ZEND_POST_DEC_OBJ_SPEC_VAR_TMP_HANDLER,
-       ZEND_POST_DEC_OBJ_SPEC_VAR_VAR_HANDLER,
+       ZEND_POST_DEC_OBJ_SPEC_VAR_TMPVAR_HANDLER,
+       ZEND_POST_DEC_OBJ_SPEC_VAR_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_POST_DEC_OBJ_SPEC_VAR_CV_HANDLER,
        ZEND_POST_DEC_OBJ_SPEC_UNUSED_CONST_HANDLER,
-       ZEND_POST_DEC_OBJ_SPEC_UNUSED_TMP_HANDLER,
-       ZEND_POST_DEC_OBJ_SPEC_UNUSED_VAR_HANDLER,
+       ZEND_POST_DEC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
+       ZEND_POST_DEC_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_POST_DEC_OBJ_SPEC_UNUSED_CV_HANDLER,
        ZEND_POST_DEC_OBJ_SPEC_CV_CONST_HANDLER,
-       ZEND_POST_DEC_OBJ_SPEC_CV_TMP_HANDLER,
-       ZEND_POST_DEC_OBJ_SPEC_CV_VAR_HANDLER,
+       ZEND_POST_DEC_OBJ_SPEC_CV_TMPVAR_HANDLER,
+       ZEND_POST_DEC_OBJ_SPEC_CV_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_POST_DEC_OBJ_SPEC_CV_CV_HANDLER,
        ZEND_NULL_HANDLER,
@@ -47163,18 +42127,18 @@ void zend_init_opcodes_handlers(void)
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_ASSIGN_OBJ_SPEC_VAR_CONST_HANDLER,
-       ZEND_ASSIGN_OBJ_SPEC_VAR_TMP_HANDLER,
-       ZEND_ASSIGN_OBJ_SPEC_VAR_VAR_HANDLER,
+       ZEND_ASSIGN_OBJ_SPEC_VAR_TMPVAR_HANDLER,
+       ZEND_ASSIGN_OBJ_SPEC_VAR_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_ASSIGN_OBJ_SPEC_VAR_CV_HANDLER,
        ZEND_ASSIGN_OBJ_SPEC_UNUSED_CONST_HANDLER,
-       ZEND_ASSIGN_OBJ_SPEC_UNUSED_TMP_HANDLER,
-       ZEND_ASSIGN_OBJ_SPEC_UNUSED_VAR_HANDLER,
+       ZEND_ASSIGN_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
+       ZEND_ASSIGN_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_ASSIGN_OBJ_SPEC_UNUSED_CV_HANDLER,
        ZEND_ASSIGN_OBJ_SPEC_CV_CONST_HANDLER,
-       ZEND_ASSIGN_OBJ_SPEC_CV_TMP_HANDLER,
-       ZEND_ASSIGN_OBJ_SPEC_CV_VAR_HANDLER,
+       ZEND_ASSIGN_OBJ_SPEC_CV_TMPVAR_HANDLER,
+       ZEND_ASSIGN_OBJ_SPEC_CV_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_ASSIGN_OBJ_SPEC_CV_CV_HANDLER,
        ZEND_NULL_HANDLER,
@@ -47453,28 +42417,28 @@ void zend_init_opcodes_handlers(void)
        ZEND_ASSIGN_DIM_SPEC_CV_UNUSED_HANDLER,
        ZEND_ASSIGN_DIM_SPEC_CV_CV_HANDLER,
        ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CONST_CONST_HANDLER,
-       ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CONST_TMP_HANDLER,
-       ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CONST_VAR_HANDLER,
+       ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CONST_TMPVAR_HANDLER,
+       ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CONST_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CONST_CV_HANDLER,
        ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_TMP_CONST_HANDLER,
-       ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_TMP_TMP_HANDLER,
-       ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_TMP_VAR_HANDLER,
+       ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_TMP_TMPVAR_HANDLER,
+       ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_TMP_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_TMP_CV_HANDLER,
        ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_CONST_HANDLER,
-       ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_TMP_HANDLER,
-       ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_VAR_HANDLER,
+       ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_TMPVAR_HANDLER,
+       ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_CV_HANDLER,
        ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_CONST_HANDLER,
-       ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_TMP_HANDLER,
-       ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_VAR_HANDLER,
+       ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
+       ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_CV_HANDLER,
        ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_CONST_HANDLER,
-       ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_TMP_HANDLER,
-       ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_VAR_HANDLER,
+       ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_TMPVAR_HANDLER,
+       ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_TMPVAR_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_CV_HANDLER,
        ZEND_HANDLE_EXCEPTION_SPEC_HANDLER,
index 45d1dd1b23db39cc8100a95566c0e611e87f69f2..60d93d8bab20c92709b0911ed2d596689b0feace 100644 (file)
@@ -100,7 +100,7 @@ $op1_type = array(
        "CONST"  => "IS_CONST",
        "UNUSED" => "IS_UNUSED",
        "CV"     => "IS_CV",
-       "TMPVAR" => "???",
+       "TMPVAR" => "(IS_TMP_VAR|IS_VAR)",
 );
 
 $op2_type = array(
@@ -110,7 +110,7 @@ $op2_type = array(
        "CONST"  => "IS_CONST",
        "UNUSED" => "IS_UNUSED",
        "CV"     => "IS_CV",
-       "TMPVAR" => "???",
+       "TMPVAR" => "(IS_TMP_VAR|IS_VAR)",
 );
 
 $op1_free = array(