]> granicus.if.org Git - php/commitdiff
Added a number of small performance tweaks and optimizations
authorDmitry Stogov <dmitry@php.net>
Tue, 20 Apr 2010 11:16:39 +0000 (11:16 +0000)
committerDmitry Stogov <dmitry@php.net>
Tue, 20 Apr 2010 11:16:39 +0000 (11:16 +0000)
  . ZEND_RECV now always has IS_CV as its result
  . ZEND_CATCH now has to be used only with constant class names
  . ZEND_FETCH_DIM_? may fetch array and dimension operans in a different order

21 files changed:
NEWS
Zend/tests/isset_003.phpt
Zend/tests/isset_003_2_4.phpt [new file with mode: 0644]
Zend/zend.h
Zend/zend_API.h
Zend/zend_compile.c
Zend/zend_compile.h
Zend/zend_execute.c
Zend/zend_execute.h
Zend/zend_execute_API.c
Zend/zend_iterators.c
Zend/zend_language_parser.y
Zend/zend_objects_API.h
Zend/zend_ptr_stack.h
Zend/zend_variables.h
Zend/zend_vm_def.h
Zend/zend_vm_execute.h
Zend/zend_vm_execute.skl
Zend/zend_vm_gen.php
ext/mbstring/mbstring.c
ext/standard/cyr_convert.c

diff --git a/NEWS b/NEWS
index 7c302b58b8874fd7c7bcb97bcd54d21138f3a22f..22a9a60e7a5bbeb7844458fb4c8abaebce4aa25b 100644 (file)
--- a/NEWS
+++ b/NEWS
@@ -4,6 +4,10 @@
 - Upgraded bundled sqlite to version 3.6.23.1. (Ilia)
 - Upgraded bundled PCRE to version 8.02. (Ilia)
 
+- Added a number of small performance tweaks and optimizations (Dmitry)
+  . ZEND_RECV now always has IS_CV as its result
+  . ZEND_CATCH now has to be used only with constant class names
+  . ZEND_FETCH_DIM_? may fetch array and dimension operans in a different order
 - Added concept of interned strings. All strings constants known at compile
   time are allocated in a single copy and never changed. (Dmitry)
 - Added an optimization which saves memory and emalloc/efree calls for empty
index 68c26f80f000f2fddac19d193d43c8d2062abfbf..8232405bee9b4bbf5edb2a446d99510a397c62c5 100644 (file)
@@ -1,5 +1,7 @@
 --TEST--
 Testing isset accessing undefined array itens and properties
+--SKIPIF--
+<?php if (version_compare(zend_version(), '2.4.0', '>=')) die('skip ZendEngine 2.3 or below needed'); ?>
 --FILE--
 <?php
 
diff --git a/Zend/tests/isset_003_2_4.phpt b/Zend/tests/isset_003_2_4.phpt
new file mode 100644 (file)
index 0000000..c05f3e2
--- /dev/null
@@ -0,0 +1,42 @@
+--TEST--
+Testing isset accessing undefined array itens and properties
+--SKIPIF--
+<?php if (version_compare(zend_version(), '2.4.0', '<')) die('skip ZendEngine 2.4 needed'); ?>
+--FILE--
+<?php
+
+$a = 'foo';
+$b =& $a;
+
+var_dump(isset($b));
+
+var_dump(isset($a[0], $b[1]));
+
+var_dump(isset($a[0]->a));
+
+var_dump(isset($c[0][1][2]->a->b->c->d));
+
+var_dump(isset(${$a}->{$b->$c[$d]}));
+
+var_dump(isset($GLOBALS));
+
+var_dump(isset($GLOBALS[1]));
+
+var_dump(isset($GLOBALS[1]->$GLOBALS));
+
+?>
+--EXPECTF--
+bool(true)
+bool(true)
+bool(false)
+bool(false)
+
+Notice: Undefined variable: c in %s on line %d
+
+Notice: Undefined variable: d in %s on line %d
+
+Notice: Trying to get property of non-object in %s on line %d
+bool(false)
+bool(true)
+bool(false)
+bool(false)
index 6348e5997cdf5f482a75b5d519906c7629bc0b33..98c36e8d24ea9d5f602faff12564daf03e18111a 100644 (file)
@@ -352,17 +352,21 @@ struct _zval_struct {
 #if defined(__GNUC__)
 #if __GNUC__ >= 3
 #define zend_always_inline inline __attribute__((always_inline))
+#define zend_never_inline __attribute__((noinline))
 #else
 #define zend_always_inline inline
+#define zend_never_inline
 #endif
 
 #elif defined(_MSC_VER)
 #define zend_always_inline __forceinline
+#define zend_never_inline
 #else
 #define zend_always_inline inline
+#define zend_never_inline
 #endif
 
-#if (defined (__GNUC__) && __GNUC__ > 2 ) && !defined(__INTEL_COMPILER) && !defined(DARWIN) && !defined(__hpux) && !defined(_AIX)
+#if (defined (__GNUC__) && __GNUC__ > 2 ) && !defined(DARWIN) && !defined(__hpux) && !defined(_AIX)
 # define EXPECTED(condition)   __builtin_expect(condition, 1)
 # define UNEXPECTED(condition) __builtin_expect(condition, 0)
 #else
@@ -677,19 +681,30 @@ END_EXTERN_C()
 
 #define PZVAL_IS_REF(z)                Z_ISREF_P(z)
 
-#define SEPARATE_ZVAL(ppzv)                                                                    \
-       {                                                                                                               \
-               zval *orig_ptr = *(ppzv);                                                       \
-                                                                                                                       \
-               if (Z_REFCOUNT_P(orig_ptr) > 1) {                                       \
-                       Z_DELREF_P(orig_ptr);                                                   \
-                       ALLOC_ZVAL(*(ppzv));                                                    \
-                       **(ppzv) = *orig_ptr;                                                   \
-                       zval_copy_ctor(*(ppzv));                                                \
-                       Z_SET_REFCOUNT_PP(ppzv, 1);                                             \
-                       Z_UNSET_ISREF_PP((ppzv));                                               \
-               }                                                                                                       \
-       }
+#define ZVAL_COPY_VALUE(z, v)                                  \
+       do {                                                                            \
+               (z)->value = (v)->value;                                \
+               Z_TYPE_P(z) = Z_TYPE_P(v);                              \
+       } while (0)
+
+#define INIT_PZVAL_COPY(z, v)                                  \
+       do {                                                                            \
+               ZVAL_COPY_VALUE(z, v);                                  \
+               Z_SET_REFCOUNT_P(z, 1);                                 \
+               Z_UNSET_ISREF_P(z);                                             \
+       } while (0)
+
+#define SEPARATE_ZVAL(ppzv)                                            \
+       do {                                                                            \
+               if (Z_REFCOUNT_PP((ppzv)) > 1) {                \
+                       zval *new_zv;                                           \
+                       Z_DELREF_PP(ppzv);                                      \
+                       ALLOC_ZVAL(new_zv);                                     \
+                       INIT_PZVAL_COPY(new_zv, *(ppzv));       \
+                       *(ppzv) = new_zv;                                       \
+                       zval_copy_ctor(new_zv);                         \
+               }                                                                               \
+       } while (0)
 
 #define SEPARATE_ZVAL_IF_NOT_REF(ppzv)         \
        if (!PZVAL_IS_REF(*ppzv)) {                             \
@@ -712,10 +727,9 @@ END_EXTERN_C()
        }                                                                               \
        INIT_PZVAL(&(zv));
        
-#define MAKE_COPY_ZVAL(ppzv, pzv) \
-       *(pzv) = **(ppzv);            \
-       zval_copy_ctor((pzv));        \
-       INIT_PZVAL((pzv));
+#define MAKE_COPY_ZVAL(ppzv, pzv)      \
+       INIT_PZVAL_COPY(pzv, *(ppzv));  \
+       zval_copy_ctor((pzv));
 
 #define REPLACE_ZVAL_VALUE(ppzv_dest, pzv_src, copy) { \
        int is_ref, refcount;                                           \
@@ -724,7 +738,7 @@ END_EXTERN_C()
        is_ref = Z_ISREF_PP(ppzv_dest);                         \
        refcount = Z_REFCOUNT_PP(ppzv_dest);            \
        zval_dtor(*ppzv_dest);                                          \
-       **ppzv_dest = *pzv_src;                                         \
+       ZVAL_COPY_VALUE(*ppzv_dest, pzv_src);           \
        if (copy) {                                 \
                zval_copy_ctor(*ppzv_dest);                             \
     }                                              \
@@ -736,10 +750,7 @@ END_EXTERN_C()
        if (PZVAL_IS_REF(varptr)) { \
                zval *original_var = varptr; \
                ALLOC_ZVAL(varptr); \
-               varptr->value = original_var->value; \
-               Z_TYPE_P(varptr) = Z_TYPE_P(original_var); \
-               Z_UNSET_ISREF_P(varptr); \
-               Z_SET_REFCOUNT_P(varptr, 1); \
+               INIT_PZVAL_COPY(varptr, original_var); \
                zval_copy_ctor(varptr); \
        } else { \
                Z_ADDREF_P(varptr); \
index 868344669bfd2837135dfc0c19750062fcb2fc04..a722b0c7a3fc8bba04d4468eb1cbf2545ecce837 100644 (file)
@@ -488,8 +488,12 @@ ZEND_API int zend_call_function(zend_fcall_info *fci, zend_fcall_info_cache *fci
 
 ZEND_API int zend_set_hash_symbol(zval *symbol, const char *name, int name_length, zend_bool is_ref, int num_symbol_tables, ...);
 
+ZEND_API void zend_delete_variable(zend_execute_data *ex, HashTable *ht, char *name, int name_len, ulong hash_value TSRMLS_DC);
+
 ZEND_API int zend_delete_global_variable(char *name, int name_len TSRMLS_DC);
 
+ZEND_API int zend_delete_global_variable_ex(char *name, int name_len, ulong hash_value TSRMLS_DC);
+
 ZEND_API void zend_reset_all_cv(HashTable *symbol_table TSRMLS_DC);
 
 ZEND_API void zend_rebuild_symbol_table(TSRMLS_D);
@@ -510,54 +514,61 @@ END_EXTERN_C()
 #define CHECK_ZVAL_STRING_REL(z)
 #endif
 
-#define ZVAL_RESOURCE(z, l) {          \
-               Z_TYPE_P(z) = IS_RESOURCE;      \
-               Z_LVAL_P(z) = l;                        \
-       }
+#define ZVAL_RESOURCE(z, l) do {       \
+               zval *__z = (z);                        \
+               Z_LVAL_P(__z) = l;                      \
+               Z_TYPE_P(__z) = IS_RESOURCE;\
+       } while (0)
 
-#define ZVAL_BOOL(z, b) {                      \
-               Z_TYPE_P(z) = IS_BOOL;          \
-               Z_LVAL_P(z) = ((b) != 0);   \
-       }
+#define ZVAL_BOOL(z, b) do {           \
+               zval *__z = (z);                        \
+               Z_LVAL_P(__z) = ((b) != 0);     \
+               Z_TYPE_P(__z) = IS_BOOL;        \
+       } while (0)
 
 #define ZVAL_NULL(z) {                         \
                Z_TYPE_P(z) = IS_NULL;          \
        }
 
 #define ZVAL_LONG(z, l) {                      \
-               Z_TYPE_P(z) = IS_LONG;          \
-               Z_LVAL_P(z) = l;                        \
+               zval *__z = (z);                        \
+               Z_LVAL_P(__z) = l;                      \
+               Z_TYPE_P(__z) = IS_LONG;        \
        }
 
 #define ZVAL_DOUBLE(z, d) {                    \
-               Z_TYPE_P(z) = IS_DOUBLE;        \
-               Z_DVAL_P(z) = d;                        \
+               zval *__z = (z);                        \
+               Z_DVAL_P(__z) = d;                      \
+               Z_TYPE_P(__z) = IS_DOUBLE;      \
        }
 
-#define ZVAL_STRING(z, s, duplicate) { \
-               const char *__s=(s);                    \
-               Z_STRLEN_P(z) = strlen(__s);    \
-               Z_STRVAL_P(z) = (duplicate?estrndup(__s, Z_STRLEN_P(z)):(char*)__s);\
-               Z_TYPE_P(z) = IS_STRING;                \
-       }
-
-#define ZVAL_STRINGL(z, s, l, duplicate) {     \
-               const char *__s=(s); int __l=l;         \
-               Z_STRLEN_P(z) = __l;                            \
-               Z_STRVAL_P(z) = (duplicate?estrndup(__s, __l):(char*)__s);\
-               Z_TYPE_P(z) = IS_STRING;                        \
-       }
-
-#define ZVAL_EMPTY_STRING(z) {         \
-               Z_STRLEN_P(z) = 0;                      \
-               Z_STRVAL_P(z) = STR_EMPTY_ALLOC();\
-               Z_TYPE_P(z) = IS_STRING;        \
-       }
+#define ZVAL_STRING(z, s, duplicate) do {      \
+               const char *__s=(s);                            \
+               zval *__z = (z);                                        \
+               Z_STRLEN_P(__z) = strlen(__s);          \
+               Z_STRVAL_P(__z) = (duplicate?estrndup(__s, Z_STRLEN_P(__z)):(char*)__s);\
+               Z_TYPE_P(__z) = IS_STRING;                      \
+       } while (0)
+
+#define ZVAL_STRINGL(z, s, l, duplicate) do {  \
+               const char *__s=(s); int __l=l;                 \
+               zval *__z = (z);                                                \
+               Z_STRLEN_P(__z) = __l;                                  \
+               Z_STRVAL_P(__z) = (duplicate?estrndup(__s, __l):(char*)__s);\
+               Z_TYPE_P(__z) = IS_STRING;                              \
+       } while (0)
+
+#define ZVAL_EMPTY_STRING(z) do {      \
+               zval *__z = (z);                        \
+               Z_STRLEN_P(__z) = 0;            \
+               Z_STRVAL_P(__z) = STR_EMPTY_ALLOC();\
+               Z_TYPE_P(__z) = IS_STRING;      \
+       } while (0)
 
 #define ZVAL_ZVAL(z, zv, copy, dtor) {                 \
                zend_uchar is_ref = Z_ISREF_P(z);               \
                zend_uint refcount = Z_REFCOUNT_P(z);   \
-               *(z) = *(zv);                                                   \
+               ZVAL_COPY_VALUE(z, zv);                                 \
                if (copy) {                                                             \
                        zval_copy_ctor(z);                                      \
            }                                                                           \
index 339d92a9cb3b1f7b1bdc62e015d3c93115ea8f84..978a458d58db63cf17c6df7ed1a0813303f39098 100644 (file)
@@ -1571,10 +1571,11 @@ void zend_do_end_function_declaration(const znode *function_token TSRMLS_DC) /*
 }
 /* }}} */
 
-void zend_do_receive_arg(zend_uchar op, const znode *var, const znode *offset, const znode *initialization, znode *class_type, const znode *varname, zend_uchar pass_by_reference TSRMLS_DC) /* {{{ */
+void zend_do_receive_arg(zend_uchar op, znode *varname, const znode *offset, const znode *initialization, znode *class_type, zend_uchar pass_by_reference TSRMLS_DC) /* {{{ */
 {
        zend_op *opline;
        zend_arg_info *cur_arg_info;
+       znode var;
 
        if (class_type->op_type == IS_CONST &&
            Z_TYPE(class_type->u.constant) == IS_STRING &&
@@ -1585,23 +1586,27 @@ void zend_do_receive_arg(zend_uchar op, const znode *var, const znode *offset, c
                return;
        }
 
-       if (var->op_type == IS_CV &&
-           var->u.op.var == CG(active_op_array)->this_var &&
-           (CG(active_op_array)->fn_flags & ZEND_ACC_STATIC) == 0) {
-               zend_error(E_COMPILE_ERROR, "Cannot re-assign $this");
-       } else if (var->op_type == IS_VAR &&
-           CG(active_op_array)->scope &&
-               ((CG(active_op_array)->fn_flags & ZEND_ACC_STATIC) == 0) &&
-               (Z_TYPE(varname->u.constant) == IS_STRING) &&
-               (Z_STRLEN(varname->u.constant) == sizeof("this")-1) &&
-               (memcmp(Z_STRVAL(varname->u.constant), "this", sizeof("this")) == 0)) {
-               zend_error(E_COMPILE_ERROR, "Cannot re-assign $this");
+       if (zend_is_auto_global(Z_STRVAL(varname->u.constant), Z_STRLEN(varname->u.constant) TSRMLS_CC)) {
+               zend_error(E_COMPILE_ERROR, "Cannot re-assign auto-global variable %s", Z_STRVAL(varname->u.constant));
+       } else {
+               var.op_type = IS_CV;
+               var.u.op.var = lookup_cv(CG(active_op_array), varname->u.constant.value.str.val, varname->u.constant.value.str.len TSRMLS_CC);
+               varname->u.constant.value.str.val = CG(active_op_array)->vars[var.u.op.var].name;
+               var.EA = 0;
+               if (Z_STRLEN(varname->u.constant) == sizeof("this")-1 &&
+                   !memcmp(Z_STRVAL(varname->u.constant), "this", sizeof("this")-1)) {
+                       if (CG(active_op_array)->scope &&
+                           (CG(active_op_array)->fn_flags & ZEND_ACC_STATIC) == 0) {
+                               zend_error(E_COMPILE_ERROR, "Cannot re-assign $this");
+                       }
+                       CG(active_op_array)->this_var = var.u.op.var;
+               }
        }
 
        opline = get_next_op(CG(active_op_array) TSRMLS_CC);
        CG(active_op_array)->num_args++;
        opline->opcode = op;
-       SET_NODE(opline->result, var);
+       SET_NODE(opline->result, &var);
        SET_NODE(opline->op1, offset);
        if (op == ZEND_RECV_INIT) {
                SET_NODE(opline->op2, initialization);
@@ -2498,16 +2503,17 @@ void zend_do_begin_catch(znode *try_token, znode *class_name, znode *catch_var,
        zend_op *opline;
        znode catch_class;
 
-       zend_do_fetch_class(&catch_class, class_name TSRMLS_CC);
+       if (class_name->op_type == IS_CONST &&
+           ZEND_FETCH_CLASS_DEFAULT == zend_get_class_fetch_type(Z_STRVAL(class_name->u.constant), Z_STRLEN(class_name->u.constant))) {
+               ulong fetch_type = ZEND_FETCH_CLASS_GLOBAL;
 
-       catch_op_number = get_next_op_number(CG(active_op_array));
-       if (catch_op_number > 0) {
-               opline = &CG(active_op_array)->opcodes[catch_op_number-1];
-               if (opline->opcode == ZEND_FETCH_CLASS) {
-                       opline->extended_value |= ZEND_FETCH_CLASS_NO_AUTOLOAD;
-               }
+               zend_resolve_class_name(class_name, &fetch_type, 1 TSRMLS_CC);
+               catch_class = *class_name;
+       } else {
+               zend_error(E_COMPILE_ERROR, "Bad class name in the catch statement");
        }
 
+       catch_op_number = get_next_op_number(CG(active_op_array));
        if (first_catch) {
                first_catch->u.op.opline_num = catch_op_number;
        }
@@ -2515,6 +2521,7 @@ void zend_do_begin_catch(znode *try_token, znode *class_name, znode *catch_var,
        opline = get_next_op(CG(active_op_array) TSRMLS_CC);
        opline->opcode = ZEND_CATCH;
        SET_NODE(opline->op1, &catch_class);
+       add_lowercased_class_name(opline->op1.constant TSRMLS_CC);
        opline->op2_type = IS_CV;
        opline->op2.var = lookup_cv(CG(active_op_array), catch_var->u.constant.value.str.val, catch_var->u.constant.value.str.len TSRMLS_CC);
        catch_var->u.constant.value.str.val = CG(active_op_array)->vars[opline->op2.var].name;
index 33e60aeb0601a708d7ff77d28c54aecc3553da81..eda42ab76752c26135781cccb9ca9bacc9bdea5f 100644 (file)
@@ -342,7 +342,6 @@ struct _zend_execute_data {
        zend_class_entry *current_called_scope;
        zval *current_this;
        zval *current_object;
-       struct _zend_op *call_opline;
 };
 
 #define EX(element) execute_data.element
@@ -440,7 +439,7 @@ void zend_do_add_variable(znode *result, const znode *op1, const znode *op2 TSRM
 int zend_do_verify_access_types(const znode *current_access_type, const znode *new_modifier);
 void zend_do_begin_function_declaration(znode *function_token, znode *function_name, int is_method, int return_reference, znode *fn_flags_znode TSRMLS_DC);
 void zend_do_end_function_declaration(const znode *function_token TSRMLS_DC);
-void zend_do_receive_arg(zend_uchar op, const znode *var, const znode *offset, const znode *initialization, znode *class_type, const znode *varname, zend_bool pass_by_reference TSRMLS_DC);
+void zend_do_receive_arg(zend_uchar op, znode *varname, const znode *offset, const znode *initialization, znode *class_type, zend_bool pass_by_reference TSRMLS_DC);
 int zend_do_begin_function_call(znode *function_name, zend_bool check_namespace TSRMLS_DC);
 void zend_do_begin_method_call(znode *left_bracket TSRMLS_DC);
 void zend_do_clone(znode *result, const znode *expr TSRMLS_DC);
index 7966ed144c38608bbb7656f02b5f103315e4725d..d4c923447ec8a80ebbd1d033f17d933c04951313 100644 (file)
@@ -60,8 +60,8 @@ static void zend_extension_fcall_end_handler(const zend_extension *extension, ze
 
 #define RETURN_VALUE_USED(opline) (!((opline)->result_type & EXT_TYPE_UNUSED))
 
-#define EX_T(offset) (*(temp_variable *)((char *) EX(Ts) + offset))
 #define T(offset) (*(temp_variable *)((char *) Ts + offset))
+#define CV(var)   CVs[var]
 
 #define TEMP_VAR_STACK_LIMIT 2000
 
@@ -92,23 +92,37 @@ static zend_always_inline void zend_pzval_unlock_free_func(zval *z TSRMLS_DC)
        }
 }
 
+static zend_never_inline void __zval_ptr_dtor(zval *zval_ptr  ZEND_FILE_LINE_DC)
+{
+       __zval_ptr_dtor(zval_ptr ZEND_FILE_LINE_RELAY_CC);
+}
+
+#undef zval_ptr_dtor
+#define zval_ptr_dtor(pzv) i_zval_ptr_dtor(*(pzv)  ZEND_FILE_LINE_CC)
+
 #define PZVAL_UNLOCK(z, f) zend_pzval_unlock_func(z, f, 1 TSRMLS_CC)
 #define PZVAL_UNLOCK_EX(z, f, u) zend_pzval_unlock_func(z, f, u TSRMLS_CC)
 #define PZVAL_UNLOCK_FREE(z) zend_pzval_unlock_free_func(z TSRMLS_CC)
 #define PZVAL_LOCK(z) Z_ADDREF_P((z))
 #define SELECTIVE_PZVAL_LOCK(pzv, opline)      if (RETURN_VALUE_USED(opline)) { PZVAL_LOCK(pzv); }
 
-#define AI_USE_PTR(ai) \
-       if ((ai).ptr_ptr) { \
-               (ai).ptr = *((ai).ptr_ptr); \
-               (ai).ptr_ptr = &((ai).ptr); \
-       } else { \
-               (ai).ptr = NULL; \
-       }
+#define EXTRACT_ZVAL_PTR(t) do {                                               \
+               temp_variable *__t = (t);                                       \
+               if (__t->var.ptr_ptr) {                                         \
+                       __t->var.ptr = *__t->var.ptr_ptr;               \
+                       __t->var.ptr_ptr = &__t->var.ptr;               \
+                       if (!PZVAL_IS_REF(__t->var.ptr) &&              \
+                           Z_REFCOUNT_P(__t->var.ptr) > 2) {   \
+                               SEPARATE_ZVAL(__t->var.ptr_ptr);        \
+                       }                                                                               \
+               }                                                                                       \
+       } while (0)
 
-#define AI_SET_PTR(ai, val)            \
-       (ai).ptr = (val);                       \
-       (ai).ptr_ptr = &((ai).ptr);
+#define AI_SET_PTR(t, val) do {                                \
+               temp_variable *__t = (t);                       \
+               __t->var.ptr = (val);                           \
+               __t->var.ptr_ptr = &__t->var.ptr;       \
+       } while (0)
 
 #define FREE_OP(should_free) \
        if (should_free.var) { \
@@ -133,21 +147,12 @@ static zend_always_inline void zend_pzval_unlock_free_func(zval *z TSRMLS_DC)
 
 #define IS_TMP_FREE(should_free) ((zend_uintptr_t)should_free.var & 1L)
 
-#define INIT_PZVAL_COPY(z,v) \
-       (z)->value = (v)->value; \
-       Z_TYPE_P(z) = Z_TYPE_P(v); \
-       Z_SET_REFCOUNT_P(z, 1); \
-       Z_UNSET_ISREF_P(z);
-
 #define MAKE_REAL_ZVAL_PTR(val) \
        do { \
                zval *_tmp; \
                ALLOC_ZVAL(_tmp); \
-               _tmp->value = (val)->value; \
-               Z_TYPE_P(_tmp) = Z_TYPE_P(val); \
-               Z_SET_REFCOUNT_P(_tmp, 1); \
-               Z_UNSET_ISREF_P(_tmp); \
-               val = _tmp; \
+               INIT_PZVAL_COPY(_tmp, (val)); \
+               (val) = _tmp; \
        } while (0)
 
 /* End of zend_execute_locks.h */
@@ -214,7 +219,7 @@ static zend_always_inline zval *_get_zval_ptr_var(zend_uint var, const temp_vari
        }
 }
 
-static zval **_get_zval_cv_lookup(zval ***ptr, zend_uint var, int type TSRMLS_DC)
+static zend_never_inline zval **_get_zval_cv_lookup(zval ***ptr, zend_uint var, int type TSRMLS_DC)
 {
        zend_compiled_variable *cv = &CV_DEF_OF(var);
 
@@ -245,6 +250,73 @@ static zval **_get_zval_cv_lookup(zval ***ptr, zend_uint var, int type TSRMLS_DC
        return *ptr;
 }
 
+static zend_never_inline zval **_get_zval_cv_lookup_BP_VAR_R(zval ***ptr, zend_uint var TSRMLS_DC)
+{
+       zend_compiled_variable *cv = &CV_DEF_OF(var);
+
+       if (!EG(active_symbol_table) ||
+           zend_hash_quick_find(EG(active_symbol_table), cv->name, cv->name_len+1, cv->hash_value, (void **)ptr)==FAILURE) {
+               zend_error(E_NOTICE, "Undefined variable: %s", cv->name);
+               return &EG(uninitialized_zval_ptr);
+       }
+       return *ptr;
+}
+
+static zend_never_inline zval **_get_zval_cv_lookup_BP_VAR_UNSET(zval ***ptr, zend_uint var TSRMLS_DC)
+{
+       zend_compiled_variable *cv = &CV_DEF_OF(var);
+
+       if (!EG(active_symbol_table) ||
+           zend_hash_quick_find(EG(active_symbol_table), cv->name, cv->name_len+1, cv->hash_value, (void **)ptr)==FAILURE) {
+               zend_error(E_NOTICE, "Undefined variable: %s", cv->name);
+               return &EG(uninitialized_zval_ptr);
+       }
+       return *ptr;
+}
+
+static zend_never_inline zval **_get_zval_cv_lookup_BP_VAR_IS(zval ***ptr, zend_uint var TSRMLS_DC)
+{
+       zend_compiled_variable *cv = &CV_DEF_OF(var);
+
+       if (!EG(active_symbol_table) ||
+           zend_hash_quick_find(EG(active_symbol_table), cv->name, cv->name_len+1, cv->hash_value, (void **)ptr)==FAILURE) {
+               return &EG(uninitialized_zval_ptr);
+       }
+       return *ptr;
+}
+
+static zend_never_inline zval **_get_zval_cv_lookup_BP_VAR_RW(zval ***ptr, zend_uint var TSRMLS_DC)
+{
+       zend_compiled_variable *cv = &CV_DEF_OF(var);
+
+       if (!EG(active_symbol_table)) {
+               Z_ADDREF(EG(uninitialized_zval));
+               *ptr = (zval**)EG(current_execute_data)->CVs + (EG(active_op_array)->last_var + var);
+               **ptr = &EG(uninitialized_zval);
+               zend_error(E_NOTICE, "Undefined variable: %s", cv->name);
+       } else if (zend_hash_quick_find(EG(active_symbol_table), cv->name, cv->name_len+1, cv->hash_value, (void **)ptr)==FAILURE) {
+               Z_ADDREF(EG(uninitialized_zval));
+               zend_hash_quick_update(EG(active_symbol_table), cv->name, cv->name_len+1, cv->hash_value, &EG(uninitialized_zval_ptr), sizeof(zval *), (void **)ptr);
+               zend_error(E_NOTICE, "Undefined variable: %s", cv->name);
+       }
+       return *ptr;
+}
+
+static zend_never_inline zval **_get_zval_cv_lookup_BP_VAR_W(zval ***ptr, zend_uint var TSRMLS_DC)
+{
+       zend_compiled_variable *cv = &CV_DEF_OF(var);
+
+       if (!EG(active_symbol_table)) {
+               Z_ADDREF(EG(uninitialized_zval));
+               *ptr = (zval**)EG(current_execute_data)->CVs + (EG(active_op_array)->last_var + var);
+               **ptr = &EG(uninitialized_zval);
+       } else if (zend_hash_quick_find(EG(active_symbol_table), cv->name, cv->name_len+1, cv->hash_value, (void **)ptr)==FAILURE) {
+               Z_ADDREF(EG(uninitialized_zval));
+               zend_hash_quick_update(EG(active_symbol_table), cv->name, cv->name_len+1, cv->hash_value, &EG(uninitialized_zval_ptr), sizeof(zval *), (void **)ptr);
+       }
+       return *ptr;
+}
+
 static zend_always_inline zval *_get_zval_ptr_cv(zend_uint var, int type TSRMLS_DC)
 {
        zval ***ptr = &CV_OF(var);
@@ -255,6 +327,56 @@ static zend_always_inline zval *_get_zval_ptr_cv(zend_uint var, int type TSRMLS_
        return **ptr;
 }
 
+static zend_always_inline zval *_get_zval_ptr_cv_BP_VAR_R(zval ***CVs, zend_uint var TSRMLS_DC)
+{
+       zval ***ptr = &CV(var);
+
+       if (UNEXPECTED(*ptr == NULL)) {
+               return *_get_zval_cv_lookup_BP_VAR_R(ptr, var TSRMLS_CC);
+       }
+       return **ptr;
+}
+
+static zend_always_inline zval *_get_zval_ptr_cv_BP_VAR_UNSET(zval ***CVs, zend_uint var TSRMLS_DC)
+{
+       zval ***ptr = &CV(var);
+
+       if (UNEXPECTED(*ptr == NULL)) {
+               return *_get_zval_cv_lookup_BP_VAR_UNSET(ptr, var TSRMLS_CC);
+       }
+       return **ptr;
+}
+
+static zend_always_inline zval *_get_zval_ptr_cv_BP_VAR_IS(zval ***CVs, zend_uint var TSRMLS_DC)
+{
+       zval ***ptr = &CV(var);
+
+       if (UNEXPECTED(*ptr == NULL)) {
+               return *_get_zval_cv_lookup_BP_VAR_IS(ptr, var TSRMLS_CC);
+       }
+       return **ptr;
+}
+
+static zend_always_inline zval *_get_zval_ptr_cv_BP_VAR_RW(zval ***CVs, zend_uint var TSRMLS_DC)
+{
+       zval ***ptr = &CV(var);
+
+       if (UNEXPECTED(*ptr == NULL)) {
+               return *_get_zval_cv_lookup_BP_VAR_RW(ptr, var TSRMLS_CC);
+       }
+       return **ptr;
+}
+
+static zend_always_inline zval *_get_zval_ptr_cv_BP_VAR_W(zval ***CVs, zend_uint var TSRMLS_DC)
+{
+       zval ***ptr = &CV(var);
+
+       if (UNEXPECTED(*ptr == NULL)) {
+               return *_get_zval_cv_lookup_BP_VAR_W(ptr, var TSRMLS_CC);
+       }
+       return **ptr;
+}
+
 static inline zval *_get_zval_ptr(int op_type, const znode_op *node, const temp_variable *Ts, zend_free_op *should_free, int type TSRMLS_DC)
 {
 /*     should_free->is_var = 0; */
@@ -306,6 +428,56 @@ static zend_always_inline zval **_get_zval_ptr_ptr_cv(zend_uint var, int type TS
        return *ptr;
 }
 
+static zend_always_inline zval **_get_zval_ptr_ptr_cv_BP_VAR_R(zval ***CVs, zend_uint var TSRMLS_DC)
+{
+       zval ***ptr = &CV(var);
+
+       if (UNEXPECTED(*ptr == NULL)) {
+               return _get_zval_cv_lookup_BP_VAR_R(ptr, var TSRMLS_CC);
+       }
+       return *ptr;
+}
+
+static zend_always_inline zval **_get_zval_ptr_ptr_cv_BP_VAR_UNSET(zval ***CVs, zend_uint var TSRMLS_DC)
+{
+       zval ***ptr = &CV(var);
+
+       if (UNEXPECTED(*ptr == NULL)) {
+               return _get_zval_cv_lookup_BP_VAR_UNSET(ptr, var TSRMLS_CC);
+       }
+       return *ptr;
+}
+
+static zend_always_inline zval **_get_zval_ptr_ptr_cv_BP_VAR_IS(zval ***CVs, zend_uint var TSRMLS_DC)
+{
+       zval ***ptr = &CV(var);
+
+       if (UNEXPECTED(*ptr == NULL)) {
+               return _get_zval_cv_lookup_BP_VAR_IS(ptr, var TSRMLS_CC);
+       }
+       return *ptr;
+}
+
+static zend_always_inline zval **_get_zval_ptr_ptr_cv_BP_VAR_RW(zval ***CVs, zend_uint var TSRMLS_DC)
+{
+       zval ***ptr = &CV(var);
+
+       if (UNEXPECTED(*ptr == NULL)) {
+               return _get_zval_cv_lookup_BP_VAR_RW(ptr, var TSRMLS_CC);
+       }
+       return *ptr;
+}
+
+static zend_always_inline zval **_get_zval_ptr_ptr_cv_BP_VAR_W(zval ***CVs, zend_uint var TSRMLS_DC)
+{
+       zval ***ptr = &CV(var);
+
+       if (UNEXPECTED(*ptr == NULL)) {
+               return _get_zval_cv_lookup_BP_VAR_W(ptr, var TSRMLS_CC);
+       }
+       return *ptr;
+}
+
 static inline zval **_get_zval_ptr_ptr(int op_type, const znode_op *node, const temp_variable *Ts, zend_free_op *should_free, int type TSRMLS_DC)
 {
        if (op_type == IS_CV) {
@@ -387,7 +559,7 @@ static void zend_assign_to_variable_reference(zval **variable_ptr_ptr, zval **va
        zval *variable_ptr = *variable_ptr_ptr;
        zval *value_ptr = *value_ptr_ptr;
 
-       if (variable_ptr == EG(error_zval_ptr) || value_ptr==EG(error_zval_ptr)) {
+       if (variable_ptr == &EG(error_zval) || value_ptr == &EG(error_zval)) {
                variable_ptr_ptr = &EG(uninitialized_zval_ptr);
        } else if (variable_ptr != value_ptr) {
                if (!PZVAL_IS_REF(value_ptr)) {
@@ -395,7 +567,7 @@ static void zend_assign_to_variable_reference(zval **variable_ptr_ptr, zval **va
                        Z_DELREF_P(value_ptr);
                        if (Z_REFCOUNT_P(value_ptr)>0) {
                                ALLOC_ZVAL(*value_ptr_ptr);
-                               **value_ptr_ptr = *value_ptr;
+                               ZVAL_COPY_VALUE(*value_ptr_ptr, value_ptr);
                                value_ptr = *value_ptr_ptr;
                                zendi_zval_copy_ctor(*value_ptr);
                        }
@@ -410,12 +582,12 @@ static void zend_assign_to_variable_reference(zval **variable_ptr_ptr, zval **va
        } else if (!Z_ISREF_P(variable_ptr)) {
                if (variable_ptr_ptr == value_ptr_ptr) {
                        SEPARATE_ZVAL(variable_ptr_ptr);
-               } else if (variable_ptr==EG(uninitialized_zval_ptr)
+               } else if (variable_ptr==&EG(uninitialized_zval)
                        || Z_REFCOUNT_P(variable_ptr)>2) {
                        /* we need to separate */
                        Z_SET_REFCOUNT_P(variable_ptr, Z_REFCOUNT_P(variable_ptr) - 2);
                        ALLOC_ZVAL(*variable_ptr_ptr);
-                       **variable_ptr_ptr = *variable_ptr;
+                       ZVAL_COPY_VALUE(*variable_ptr_ptr, variable_ptr);
                        zval_copy_ctor(*variable_ptr_ptr);
                        *value_ptr_ptr = *variable_ptr_ptr;
                        Z_SET_REFCOUNT_PP(variable_ptr_ptr, 2);
@@ -451,7 +623,7 @@ static inline char * zend_verify_arg_class_kind(const zend_arg_info *cur_arg_inf
        }
 }
 
-static inline int zend_verify_arg_error(const zend_function *zf, zend_uint arg_num, const zend_arg_info *cur_arg_info, const char *need_msg, const char *need_kind, const char *given_msg, char *given_kind TSRMLS_DC)
+static inline int zend_verify_arg_error(const zend_function *zf, zend_uint arg_num, const char *need_msg, const char *need_kind, const char *given_msg, char *given_kind TSRMLS_DC)
 {
        zend_execute_data *ptr = EG(current_execute_data)->prev_execute_data;
        char *fname = zf->common.function_name;
@@ -492,23 +664,23 @@ static inline int zend_verify_arg_type(zend_function *zf, zend_uint arg_num, zva
 
                if (!arg) {
                        need_msg = zend_verify_arg_class_kind(cur_arg_info, fetch_type, &class_name, &ce TSRMLS_CC);
-                       return zend_verify_arg_error(zf, arg_num, cur_arg_info, need_msg, class_name, "none", "" TSRMLS_CC);
+                       return zend_verify_arg_error(zf, arg_num, need_msg, class_name, "none", "" TSRMLS_CC);
                }
                if (Z_TYPE_P(arg) == IS_OBJECT) {
                        need_msg = zend_verify_arg_class_kind(cur_arg_info, fetch_type, &class_name, &ce TSRMLS_CC);
                        if (!ce || !instanceof_function(Z_OBJCE_P(arg), ce TSRMLS_CC)) {
-                               return zend_verify_arg_error(zf, arg_num, cur_arg_info, need_msg, class_name, "instance of ", Z_OBJCE_P(arg)->name TSRMLS_CC);
+                               return zend_verify_arg_error(zf, arg_num, need_msg, class_name, "instance of ", Z_OBJCE_P(arg)->name TSRMLS_CC);
                        }
                } else if (Z_TYPE_P(arg) != IS_NULL || !cur_arg_info->allow_null) {
                        need_msg = zend_verify_arg_class_kind(cur_arg_info, fetch_type, &class_name, &ce TSRMLS_CC);
-                       return zend_verify_arg_error(zf, arg_num, cur_arg_info, need_msg, class_name, zend_zval_type_name(arg), "" TSRMLS_CC);
+                       return zend_verify_arg_error(zf, arg_num, need_msg, class_name, zend_zval_type_name(arg), "" TSRMLS_CC);
                }
        } else if (cur_arg_info->array_type_hint) {
                if (!arg) {
-                       return zend_verify_arg_error(zf, arg_num, cur_arg_info, "be an array", "", "none", "" TSRMLS_CC);
+                       return zend_verify_arg_error(zf, arg_num, "be an array", "", "none", "" TSRMLS_CC);
                }
                if (Z_TYPE_P(arg) != IS_ARRAY && (Z_TYPE_P(arg) != IS_NULL || !cur_arg_info->allow_null)) {
-                       return zend_verify_arg_error(zf, arg_num, cur_arg_info, "be an array", "", zend_zval_type_name(arg), "" TSRMLS_CC);
+                       return zend_verify_arg_error(zf, arg_num, "be an array", "", zend_zval_type_name(arg), "" TSRMLS_CC);
                }
        }
        return 1;
@@ -521,9 +693,9 @@ static inline void zend_assign_to_object(zval **retval, zval **object_ptr, zval
        zval *value = get_zval_ptr(value_type, value_op, Ts, &free_value, BP_VAR_R);
 
        if (Z_TYPE_P(object) != IS_OBJECT) {
-               if (object == EG(error_zval_ptr)) {
+               if (object == &EG(error_zval)) {
                        if (retval) {
-                               *retval = EG(uninitialized_zval_ptr);
+                               *retval = &EG(uninitialized_zval);
                                PZVAL_LOCK(*retval);
                        }
                        FREE_OP(free_value);
@@ -540,7 +712,7 @@ static inline void zend_assign_to_object(zval **retval, zval **object_ptr, zval
                } else {
                        zend_error(E_WARNING, "Attempt to assign property of non-object");
                        if (retval) {
-                               *retval = EG(uninitialized_zval_ptr);
+                               *retval = &EG(uninitialized_zval);
                                PZVAL_LOCK(*retval);
                        }
                        FREE_OP(free_value);
@@ -553,14 +725,14 @@ static inline void zend_assign_to_object(zval **retval, zval **object_ptr, zval
                zval *orig_value = value;
 
                ALLOC_ZVAL(value);
-               *value = *orig_value;
+               ZVAL_COPY_VALUE(value, orig_value);
                Z_UNSET_ISREF_P(value);
                Z_SET_REFCOUNT_P(value, 0);
        } else if (value_type == IS_CONST) {
                zval *orig_value = value;
 
                ALLOC_ZVAL(value);
-               *value = *orig_value;
+               ZVAL_COPY_VALUE(value, orig_value);
                Z_UNSET_ISREF_P(value);
                Z_SET_REFCOUNT_P(value, 0);
                zval_copy_ctor(value);
@@ -572,8 +744,8 @@ static inline void zend_assign_to_object(zval **retval, zval **object_ptr, zval
                if (!Z_OBJ_HT_P(object)->write_property) {
                        zend_error(E_WARNING, "Attempt to assign property of non-object");
                        if (retval) {
-                               *retval = EG(uninitialized_zval_ptr);
-                               PZVAL_LOCK(*retval);
+                               *retval = &EG(uninitialized_zval);
+                               PZVAL_LOCK(&EG(uninitialized_zval));
                        }
                        if (value_type == IS_TMP_VAR) {
                                FREE_ZVAL(value);
@@ -631,8 +803,9 @@ static inline int zend_assign_to_string_offset(const temp_variable *T, const zva
                }
 
                if (Z_TYPE_P(value) != IS_STRING) {
-                       zval tmp = *value;
-
+                       zval tmp;
+                       
+                       ZVAL_COPY_VALUE(&tmp, value);
                        if (value_type != IS_TMP_VAR) {
                                zval_copy_ctor(&tmp);
                        }
@@ -656,88 +829,104 @@ static inline int zend_assign_to_string_offset(const temp_variable *T, const zva
        return 1;
 }
 
-static inline zval* zend_assign_to_variable(zval **variable_ptr_ptr, zval *value, int is_tmp_var TSRMLS_DC)
+
+static inline zval* zend_assign_tmp_to_variable(zval **variable_ptr_ptr, zval *value TSRMLS_DC)
 {
        zval *variable_ptr = *variable_ptr_ptr;
        zval garbage;
 
-       if (variable_ptr == EG(error_zval_ptr)) {
-               if (is_tmp_var) {
-                       zval_dtor(value);
-               }
-               return EG(uninitialized_zval_ptr);
-       }
-
-       if (Z_TYPE_P(variable_ptr) == IS_OBJECT && Z_OBJ_HANDLER_P(variable_ptr, set)) {
+       if (Z_TYPE_P(variable_ptr) == IS_OBJECT &&
+           UNEXPECTED(Z_OBJ_HANDLER_P(variable_ptr, set) != NULL)) {
                Z_OBJ_HANDLER_P(variable_ptr, set)(variable_ptr_ptr, value TSRMLS_CC);
                return variable_ptr;
        }
 
-       if (PZVAL_IS_REF(variable_ptr)) {
-               if (variable_ptr!=value) {
+       if (EXPECTED(!PZVAL_IS_REF(variable_ptr))) {
+               if (Z_DELREF_P(variable_ptr)==0) {
+                       ZVAL_COPY_VALUE(&garbage, variable_ptr);
+                       INIT_PZVAL_COPY(variable_ptr, value);
+                       zendi_zval_dtor(garbage);
+                       return variable_ptr;
+               } else { /* we need to split */
+                       ALLOC_ZVAL(variable_ptr);
+                       INIT_PZVAL_COPY(variable_ptr, value);
+                       *variable_ptr_ptr = variable_ptr;
+                       return variable_ptr;
+               }
+       } else {
+               if (EXPECTED(variable_ptr != value)) {
                        zend_uint refcount = Z_REFCOUNT_P(variable_ptr);
 
-                       garbage = *variable_ptr;
-                       *variable_ptr = *value;
+                       ZVAL_COPY_VALUE(&garbage, variable_ptr);
+                       ZVAL_COPY_VALUE(variable_ptr, value);
                        Z_SET_REFCOUNT_P(variable_ptr, refcount);
                        Z_SET_ISREF_P(variable_ptr);
-                       if (!is_tmp_var) {
-                               zendi_zval_copy_ctor(*variable_ptr);
-                       }
                        zendi_zval_dtor(garbage);
-                       return variable_ptr;
                }
-       } else {
+               return variable_ptr;
+       }
+}
+
+
+static inline zval* zend_assign_to_variable(zval **variable_ptr_ptr, zval *value TSRMLS_DC)
+{
+       zval *variable_ptr = *variable_ptr_ptr;
+       zval garbage;
+
+       if (Z_TYPE_P(variable_ptr) == IS_OBJECT &&
+           UNEXPECTED(Z_OBJ_HANDLER_P(variable_ptr, set) != NULL)) {
+               Z_OBJ_HANDLER_P(variable_ptr, set)(variable_ptr_ptr, value TSRMLS_CC);
+               return variable_ptr;
+       }
+
+       if (EXPECTED(!PZVAL_IS_REF(variable_ptr))) {
                if (Z_DELREF_P(variable_ptr)==0) {
-                       if (!is_tmp_var) {
-                               if (variable_ptr==value) {
-                                       Z_ADDREF_P(variable_ptr);
-                               } else if (PZVAL_IS_REF(value)) {
-                                       garbage = *variable_ptr;
-                                       *variable_ptr = *value;
-                                       INIT_PZVAL(variable_ptr);
-                                       zval_copy_ctor(variable_ptr);
-                                       zendi_zval_dtor(garbage);
-                                       return variable_ptr;
-                               } else {
-                                       Z_ADDREF_P(value);
-                                       *variable_ptr_ptr = value;
-                                       if (variable_ptr != &EG(uninitialized_zval)) {
-                                               GC_REMOVE_ZVAL_FROM_BUFFER(variable_ptr);
-                                               zval_dtor(variable_ptr);
-                                               efree(variable_ptr);
-                                       }
-                                       return value;
-                               }
-                       } else {
-                               garbage = *variable_ptr;
-                               *variable_ptr = *value;
-                               INIT_PZVAL(variable_ptr);
+                       if (variable_ptr==value) {
+                               Z_ADDREF_P(variable_ptr);
+                               return variable_ptr;
+                       } else if (PZVAL_IS_REF(value)) {
+                               ZVAL_COPY_VALUE(&garbage, variable_ptr);
+                               INIT_PZVAL_COPY(variable_ptr, value);
+                               zval_copy_ctor(variable_ptr);
                                zendi_zval_dtor(garbage);
                                return variable_ptr;
+                       } else {
+                               Z_ADDREF_P(value);
+                               *variable_ptr_ptr = value;
+                               if (variable_ptr != &EG(uninitialized_zval)) {
+                                       GC_REMOVE_ZVAL_FROM_BUFFER(variable_ptr);
+                                       zval_dtor(variable_ptr);
+                                       efree(variable_ptr);
+                               }
+                               return value;
                        }
                } else { /* we need to split */
-                       if (!is_tmp_var) {
-                               if (PZVAL_IS_REF(value) && Z_REFCOUNT_P(value) > 0) {
-                                       ALLOC_ZVAL(variable_ptr);
-                                       *variable_ptr_ptr = variable_ptr;
-                                       *variable_ptr = *value;
-                                       zval_copy_ctor(variable_ptr);
-                                       Z_SET_REFCOUNT_P(variable_ptr, 1);
-                               } else {
-                                       *variable_ptr_ptr = value;
-                                       Z_ADDREF_P(value);
-                               }
+                       if (PZVAL_IS_REF(value) && Z_REFCOUNT_P(value) > 0) {
+                               ALLOC_ZVAL(variable_ptr);
+                               INIT_PZVAL_COPY(variable_ptr, value);
+                               zval_copy_ctor(variable_ptr);
+                               *variable_ptr_ptr = variable_ptr;
+                               return variable_ptr;
                        } else {
-                               ALLOC_ZVAL(*variable_ptr_ptr);
-                               Z_SET_REFCOUNT_P(value, 1);
-                               **variable_ptr_ptr = *value;
+                               *variable_ptr_ptr = value;
+                               Z_ADDREF_P(value);
+                               Z_UNSET_ISREF_P(value);
+                               return value;
                        }
                }
-               Z_UNSET_ISREF_PP(variable_ptr_ptr);
-       }
+       } else {
+               if (EXPECTED(variable_ptr != value)) {
+                       zend_uint refcount = Z_REFCOUNT_P(variable_ptr);
 
-       return *variable_ptr_ptr;
+                       ZVAL_COPY_VALUE(&garbage, variable_ptr);
+                       ZVAL_COPY_VALUE(variable_ptr, value);
+                       Z_SET_REFCOUNT_P(variable_ptr, refcount);
+                       Z_SET_ISREF_P(variable_ptr);
+                       zendi_zval_copy_ctor(*variable_ptr);
+                       zendi_zval_dtor(garbage);
+               }
+               return variable_ptr;
+       }
 }
 
 
@@ -916,7 +1105,7 @@ fetch_from_array:
                        break;
 
                case IS_NULL:
-                       if (container == EG(error_zval_ptr)) {
+                       if (container == &EG(error_zval)) {
                                result->var.ptr_ptr = &EG(error_zval_ptr);
                                PZVAL_LOCK(EG(error_zval_ptr));
                        } else if (type != BP_VAR_UNSET) {
@@ -997,7 +1186,7 @@ convert_to_array:
                                                        zval *tmp = overloaded_result;
 
                                                        ALLOC_ZVAL(overloaded_result);
-                                                       *overloaded_result = *tmp;
+                                                       ZVAL_COPY_VALUE(overloaded_result, tmp);
                                                        zval_copy_ctor(overloaded_result);
                                                        Z_UNSET_ISREF_P(overloaded_result);
                                                        Z_SET_REFCOUNT_P(overloaded_result, 0);
@@ -1011,7 +1200,7 @@ convert_to_array:
                                } else {
                                        retval = &EG(error_zval_ptr);
                                }
-                               AI_SET_PTR(result->var, *retval);
+                               AI_SET_PTR(result, *retval);
                                PZVAL_LOCK(*retval);
                                if (dim_type == IS_TMP_VAR) {
                                        zval_ptr_dtor(&dim);
@@ -1029,8 +1218,8 @@ convert_to_array:
                default:
                        if (type == BP_VAR_UNSET) {
                                zend_error(E_WARNING, "Cannot unset offset in a non-array variable");
-                               AI_SET_PTR(result->var, EG(uninitialized_zval_ptr));
-                               PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                               AI_SET_PTR(result, &EG(uninitialized_zval));
+                               PZVAL_LOCK(&EG(uninitialized_zval));
                        } else {
                                zend_error(E_WARNING, "Cannot use a scalar value as an array");
                                result->var.ptr_ptr = &EG(error_zval_ptr);
@@ -1050,7 +1239,7 @@ static void zend_fetch_dimension_address_read(temp_variable *result, zval **cont
                case IS_ARRAY:
                        retval = zend_fetch_dimension_address_inner(Z_ARRVAL_P(container), dim, dim_type, type TSRMLS_CC);
                        if (result) {
-                               AI_SET_PTR(result->var, *retval);
+                               AI_SET_PTR(result, *retval);
                                PZVAL_LOCK(*retval);
                        }
                        return;
@@ -1058,8 +1247,8 @@ static void zend_fetch_dimension_address_read(temp_variable *result, zval **cont
 
                case IS_NULL:
                        if (result) {
-                               AI_SET_PTR(result->var, EG(uninitialized_zval_ptr));
-                               PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                               AI_SET_PTR(result, &EG(uninitialized_zval));
+                               PZVAL_LOCK(&EG(uninitialized_zval));
                        }
                        return;
                        break;
@@ -1081,7 +1270,7 @@ static void zend_fetch_dimension_address_read(temp_variable *result, zval **cont
                                                        break;
                                        }
 
-                                       tmp = *dim;
+                                       ZVAL_COPY_VALUE(&tmp, dim);
                                        zval_copy_ctor(&tmp);
                                        convert_to_long(&tmp);
                                        dim = &tmp;
@@ -1115,7 +1304,7 @@ static void zend_fetch_dimension_address_read(temp_variable *result, zval **cont
 
                                if (overloaded_result) {
                                        if (result) {
-                                               AI_SET_PTR(result->var, overloaded_result);
+                                               AI_SET_PTR(result, overloaded_result);
                                                PZVAL_LOCK(overloaded_result);
                                        } else if (Z_REFCOUNT_P(overloaded_result) == 0) {
                                                /* Destroy unused result from offsetGet() magic method */
@@ -1123,8 +1312,8 @@ static void zend_fetch_dimension_address_read(temp_variable *result, zval **cont
                                                zval_ptr_dtor(&overloaded_result);
                                        }
                                } else if (result) {
-                                       AI_SET_PTR(result->var, EG(uninitialized_zval_ptr));
-                                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                                       AI_SET_PTR(result, &EG(uninitialized_zval));
+                                       PZVAL_LOCK(&EG(uninitialized_zval));
                                }
                                if (dim_type == IS_TMP_VAR) {
                                        zval_ptr_dtor(&dim);
@@ -1135,8 +1324,8 @@ static void zend_fetch_dimension_address_read(temp_variable *result, zval **cont
 
                default:
                        if (result) {
-                               AI_SET_PTR(result->var, EG(uninitialized_zval_ptr));
-                               PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                               AI_SET_PTR(result, &EG(uninitialized_zval));
+                               PZVAL_LOCK(&EG(uninitialized_zval));
                        }
                        return;
                        break;
@@ -1148,9 +1337,9 @@ static void zend_fetch_property_address(temp_variable *result, zval **container_
        zval *container = *container_ptr;;
 
        if (Z_TYPE_P(container) != IS_OBJECT) {
-               if (container == EG(error_zval_ptr)) {
+               if (container == &EG(error_zval)) {
                        result->var.ptr_ptr = &EG(error_zval_ptr);
-                       PZVAL_LOCK(*result->var.ptr_ptr);
+                       PZVAL_LOCK(EG(error_zval_ptr));
                        return;
                }
 
@@ -1179,7 +1368,7 @@ static void zend_fetch_property_address(temp_variable *result, zval **container_
 
                        if (Z_OBJ_HT_P(container)->read_property &&
                                (ptr = Z_OBJ_HT_P(container)->read_property(container, prop_ptr, type, key TSRMLS_CC)) != NULL) {
-                               AI_SET_PTR(result->var, ptr);
+                               AI_SET_PTR(result, ptr);
                                PZVAL_LOCK(ptr);
                        } else {
                                zend_error_noreturn(E_ERROR, "Cannot access undefined property for object with overloaded property access");
@@ -1191,7 +1380,7 @@ static void zend_fetch_property_address(temp_variable *result, zval **container_
        } else if (Z_OBJ_HT_P(container)->read_property) {
                zval *ptr = Z_OBJ_HT_P(container)->read_property(container, prop_ptr, type, key TSRMLS_CC);
 
-               AI_SET_PTR(result->var, ptr);
+               AI_SET_PTR(result, ptr);
                PZVAL_LOCK(ptr);
        } else {
                zend_error(E_WARNING, "This object doesn't support property references");
@@ -1283,22 +1472,29 @@ ZEND_API void execute_internal(zend_execute_data *execute_data_ptr, int return_v
 
 #define ZEND_VM_NEXT_OPCODE() \
        CHECK_SYMBOL_TABLES() \
-       EX(opline)++; \
+       ZEND_VM_INC_OPCODE(); \
        ZEND_VM_CONTINUE()
 
 #define ZEND_VM_SET_OPCODE(new_op) \
        CHECK_SYMBOL_TABLES() \
-       EX(opline) = new_op
+       OPLINE = new_op
 
 #define ZEND_VM_JMP(new_op) \
-       CHECK_SYMBOL_TABLES() \
        if (EXPECTED(!EG(exception))) { \
-               EX(opline) = new_op; \
+               ZEND_VM_SET_OPCODE(new_op); \
+       } else { \
+               LOAD_OPLINE(); \
        } \
        ZEND_VM_CONTINUE()
 
 #define ZEND_VM_INC_OPCODE() \
-       EX(opline)++
+       OPLINE++
+
+#ifdef __GNUC__
+# define ZEND_VM_GUARD(name) __asm__("#" #name)
+#else
+# define ZEND_VM_GUARD(name)
+#endif
 
 #include "zend_vm_execute.h"
 
index 368875c03c8f9cb1445ace28121f82b0a4c45f66..28e26d393249c0cb6312a460ca12886df775264a 100644 (file)
@@ -62,7 +62,7 @@ ZEND_API void execute(zend_op_array *op_array TSRMLS_DC);
 ZEND_API void execute_internal(zend_execute_data *execute_data_ptr, int return_value_used TSRMLS_DC);
 ZEND_API int zend_is_true(zval *op);
 #define safe_free_zval_ptr(p) safe_free_zval_ptr_rel(p ZEND_FILE_LINE_CC ZEND_FILE_LINE_EMPTY_CC)
-static inline void safe_free_zval_ptr_rel(zval *p ZEND_FILE_LINE_DC ZEND_FILE_LINE_ORIG_DC)
+static zend_always_inline void safe_free_zval_ptr_rel(zval *p ZEND_FILE_LINE_DC ZEND_FILE_LINE_ORIG_DC)
 {
        TSRMLS_FETCH();
 
@@ -77,7 +77,28 @@ ZEND_API int zend_eval_stringl(char *str, int str_len, zval *retval_ptr, char *s
 ZEND_API int zend_eval_string_ex(char *str, zval *retval_ptr, char *string_name, int handle_exceptions TSRMLS_DC);
 ZEND_API int zend_eval_stringl_ex(char *str, int str_len, zval *retval_ptr, char *string_name, int handle_exceptions TSRMLS_DC);
 
-static inline int i_zend_is_true(zval *op)
+static zend_always_inline void i_zval_ptr_dtor(zval *zval_ptr ZEND_FILE_LINE_DC)
+{
+       if (!Z_DELREF_P(zval_ptr)) {
+               TSRMLS_FETCH();
+
+               if (zval_ptr != &EG(uninitialized_zval)) {
+                       GC_REMOVE_ZVAL_FROM_BUFFER(zval_ptr);
+                       zval_dtor(zval_ptr);
+                       efree_rel(zval_ptr);
+               }
+       } else {
+               TSRMLS_FETCH();
+
+               if (Z_REFCOUNT_P(zval_ptr) == 1) {
+                       Z_UNSET_ISREF_P(zval_ptr);
+               }
+
+               GC_ZVAL_CHECK_POSSIBLE_ROOT(zval_ptr);
+       }
+}
+
+static zend_always_inline int i_zend_is_true(zval *op)
 {
        int result;
 
@@ -157,7 +178,7 @@ struct _zend_vm_stack {
                }                                                                                                                       \
        } while (0)
 
-static inline zend_vm_stack zend_vm_stack_new_page(int count) {
+static zend_always_inline zend_vm_stack zend_vm_stack_new_page(int count) {
        zend_vm_stack page = (zend_vm_stack)emalloc(ZEND_MM_ALIGNED_SIZE(sizeof(*page)) + sizeof(void*) * count);
 
        page->top = ZEND_VM_STACK_ELEMETS(page);
@@ -166,12 +187,12 @@ static inline zend_vm_stack zend_vm_stack_new_page(int count) {
        return page;
 }
 
-static inline void zend_vm_stack_init(TSRMLS_D)
+static zend_always_inline void zend_vm_stack_init(TSRMLS_D)
 {
        EG(argument_stack) = zend_vm_stack_new_page(ZEND_VM_STACK_PAGE_SIZE);
 }
 
-static inline void zend_vm_stack_destroy(TSRMLS_D)
+static zend_always_inline void zend_vm_stack_destroy(TSRMLS_D)
 {
        zend_vm_stack stack = EG(argument_stack);
 
@@ -182,30 +203,30 @@ static inline void zend_vm_stack_destroy(TSRMLS_D)
        }
 }
 
-static inline void zend_vm_stack_extend(int count TSRMLS_DC)
+static zend_always_inline void zend_vm_stack_extend(int count TSRMLS_DC)
 {
        zend_vm_stack p = zend_vm_stack_new_page(count >= ZEND_VM_STACK_PAGE_SIZE ? count : ZEND_VM_STACK_PAGE_SIZE);
        p->prev = EG(argument_stack);
        EG(argument_stack) = p;
 }
 
-static inline void **zend_vm_stack_top(TSRMLS_D)
+static zend_always_inline void **zend_vm_stack_top(TSRMLS_D)
 {
        return EG(argument_stack)->top;
 }
 
-static inline void zend_vm_stack_push(void *ptr TSRMLS_DC)
+static zend_always_inline void zend_vm_stack_push(void *ptr TSRMLS_DC)
 {
        ZEND_VM_STACK_GROW_IF_NEEDED(1);
        *(EG(argument_stack)->top++) = ptr;
 }
 
-static inline void zend_vm_stack_push_nocheck(void *ptr TSRMLS_DC)
+static zend_always_inline void zend_vm_stack_push_nocheck(void *ptr TSRMLS_DC)
 {
        *(EG(argument_stack)->top++) = ptr;
 }
 
-static inline void *zend_vm_stack_pop(TSRMLS_D)
+static zend_always_inline void *zend_vm_stack_pop(TSRMLS_D)
 {
        void *el = *(--EG(argument_stack)->top);
 
@@ -217,7 +238,7 @@ static inline void *zend_vm_stack_pop(TSRMLS_D)
        return el;
 }
 
-static inline void *zend_vm_stack_alloc(size_t size TSRMLS_DC)
+static zend_always_inline void *zend_vm_stack_alloc(size_t size TSRMLS_DC)
 {
        void *ret;
 
@@ -246,7 +267,7 @@ static inline void *zend_vm_stack_alloc(size_t size TSRMLS_DC)
        return ret;
 }
 
-static inline void zend_vm_stack_free_int(void *ptr TSRMLS_DC)
+static zend_always_inline void zend_vm_stack_free_int(void *ptr TSRMLS_DC)
 {      
        if (UNEXPECTED(ZEND_VM_STACK_ELEMETS(EG(argument_stack)) == (void**)ptr)) {
                zend_vm_stack p = EG(argument_stack);
@@ -258,7 +279,7 @@ static inline void zend_vm_stack_free_int(void *ptr TSRMLS_DC)
        }
 }
 
-static inline void zend_vm_stack_free(void *ptr TSRMLS_DC)
+static zend_always_inline void zend_vm_stack_free(void *ptr TSRMLS_DC)
 {      
        if (UNEXPECTED(ZEND_VM_STACK_ELEMETS(EG(argument_stack)) == (void**)ptr)) {
                zend_vm_stack p = EG(argument_stack);
@@ -276,7 +297,7 @@ static inline void zend_vm_stack_free(void *ptr TSRMLS_DC)
        }
 }
 
-static inline void** zend_vm_stack_push_args(int count TSRMLS_DC)
+static zend_always_inline void** zend_vm_stack_push_args(int count TSRMLS_DC)
 {
 
        if (UNEXPECTED(EG(argument_stack)->top - ZEND_VM_STACK_ELEMETS(EG(argument_stack)) < count)  || 
@@ -305,7 +326,7 @@ static inline void** zend_vm_stack_push_args(int count TSRMLS_DC)
        return EG(argument_stack)->top++;
 }
 
-static inline void zend_vm_stack_clear_multiple(TSRMLS_D)
+static zend_always_inline void zend_vm_stack_clear_multiple(TSRMLS_D)
 {
        void **p = EG(argument_stack)->top - 1;
        int delete_count = (int)(zend_uintptr_t) *p;
@@ -313,12 +334,12 @@ static inline void zend_vm_stack_clear_multiple(TSRMLS_D)
        while (--delete_count>=0) {
                zval *q = *(zval **)(--p);
                *p = NULL;
-               zval_ptr_dtor(&q);
+               i_zval_ptr_dtor(q ZEND_FILE_LINE_CC);
        }
        zend_vm_stack_free_int(p TSRMLS_CC);
 }
 
-static inline zval** zend_vm_stack_get_arg(int requested_arg TSRMLS_DC)
+static zend_always_inline zval** zend_vm_stack_get_arg(int requested_arg TSRMLS_DC)
 {
        void **p = EG(current_execute_data)->prev_execute_data->function_state.arguments;
        int arg_count = (int)(zend_uintptr_t) *p;
@@ -329,7 +350,7 @@ static inline zval** zend_vm_stack_get_arg(int requested_arg TSRMLS_DC)
        return (zval**)p - arg_count + requested_arg - 1;
 }
 
-static inline void zend_arg_types_stack_2_pop(zend_ptr_stack *stack, zval **object, zend_function **fbc)
+static zend_always_inline void zend_arg_types_stack_2_pop(zend_ptr_stack *stack, zval **object, zend_function **fbc)
 {
        void *a, *b;
 
@@ -339,7 +360,7 @@ static inline void zend_arg_types_stack_2_pop(zend_ptr_stack *stack, zval **obje
        *fbc = (zend_function *) b;
 }
 
-static inline void zend_arg_types_stack_3_pop(zend_ptr_stack *stack, zend_class_entry **called_scope, zval **object, zend_function **fbc)
+static zend_always_inline void zend_arg_types_stack_3_pop(zend_ptr_stack *stack, zend_class_entry **called_scope, zval **object, zend_function **fbc)
 {
        void *a, *b, *c;
 
index fd4fb928e466dadcf1f84b4fb79ee5e8513bbf0b..5203f4fe86d4d1e9c8c56189a0cacf1b04463892 100644 (file)
@@ -1665,12 +1665,34 @@ ZEND_API void zend_reset_all_cv(HashTable *symbol_table TSRMLS_DC) /* {{{ */
 }
 /* }}} */
 
-ZEND_API int zend_delete_global_variable(char *name, int name_len TSRMLS_DC) /* {{{ */
+ZEND_API void zend_delete_variable(zend_execute_data *ex, HashTable *ht, char *name, int name_len, ulong hash_value TSRMLS_DC) /* {{{ */
+{
+       if (zend_hash_quick_del(ht, name, name_len, hash_value) == SUCCESS) {
+               name_len--;
+               while (ex && ex->symbol_table == ht) {
+                       int i;
+
+                       if (ex->op_array) {
+                               for (i = 0; i < ex->op_array->last_var; i++) {
+                                       if (ex->op_array->vars[i].hash_value == hash_value &&
+                                               ex->op_array->vars[i].name_len == name_len &&
+                                               !memcmp(ex->op_array->vars[i].name, name, name_len)) {
+                                               ex->CVs[i] = NULL;
+                                               break;
+                                       }
+                               }
+                       }
+                       ex = ex->prev_execute_data;
+               }
+       }
+}
+/* }}} */
+
+ZEND_API int zend_delete_global_variable_ex(char *name, int name_len, ulong hash_value TSRMLS_DC) /* {{{ */
 {
        zend_execute_data *ex;
-       ulong hash_value = zend_inline_hash_func(name, name_len + 1);
 
-       if (zend_hash_quick_exists(&EG(symbol_table), name, name_len + 1, hash_value)) {
+       if (zend_hash_quick_del(&EG(symbol_table), name, name_len + 1, hash_value) == SUCCESS) {
                for (ex = EG(current_execute_data); ex; ex = ex->prev_execute_data) {
                        if (ex->op_array && ex->symbol_table == &EG(symbol_table)) {
                                int i;
@@ -1685,12 +1707,18 @@ ZEND_API int zend_delete_global_variable(char *name, int name_len TSRMLS_DC) /*
                                }
                        }
                }
-               return zend_hash_quick_del(&EG(symbol_table), name, name_len + 1, hash_value);
+               return SUCCESS;
        }
        return FAILURE;
 }
 /* }}} */
 
+ZEND_API int zend_delete_global_variable(char *name, int name_len TSRMLS_DC) /* {{{ */
+{
+       return zend_delete_global_variable_ex(name, name_len, zend_inline_hash_func(name, name_len + 1) TSRMLS_CC);
+}
+/* }}} */
+
 ZEND_API void zend_rebuild_symbol_table(TSRMLS_D) /* {{{ */
 {
        zend_uint i;
index 84b3638f0b5f0dc99375cd40df4920772f8fb29a..533cd5384aa2c685377594ddca27ba159e6bc6d6 100755 (executable)
@@ -82,13 +82,13 @@ ZEND_API enum zend_object_iterator_kind zend_iterator_unwrap(
                                *iter = (zend_object_iterator *)zend_object_store_get_object(array_ptr TSRMLS_CC);
                                return ZEND_ITER_OBJECT;
                        }
-                       if (HASH_OF(array_ptr)) {
+                       if (Z_OBJPROP_P(array_ptr)) {
                                return ZEND_ITER_PLAIN_OBJECT;
                        }
                        return ZEND_ITER_INVALID;
 
                case IS_ARRAY:
-                       if (HASH_OF(array_ptr)) {
+                       if (Z_ARRVAL_P(array_ptr)) {
                                return ZEND_ITER_PLAIN_ARRAY;
                        }
                        return ZEND_ITER_INVALID;
index 4b891bc3355e31c0ff9023b593b4cb62c6ffeb47..2c9513182ac3cc6070fac08733b0ccccafeab7e5 100644 (file)
@@ -450,14 +450,14 @@ parameter_list:
 
 
 non_empty_parameter_list:
-               optional_class_type T_VARIABLE                          { znode tmp;  fetch_simple_variable(&tmp, &$2, 0 TSRMLS_CC); $$.op_type = IS_UNUSED; $$.u.op.num=1; Z_TYPE($$.u.constant)=IS_LONG; INIT_PZVAL(&$$.u.constant); zend_do_receive_arg(ZEND_RECV, &tmp, &$$, NULL, &$1, &$2, 0 TSRMLS_CC); }
-       |       optional_class_type '&' T_VARIABLE                      { znode tmp;  fetch_simple_variable(&tmp, &$3, 0 TSRMLS_CC); $$.op_type = IS_UNUSED; $$.u.op.num=1; Z_TYPE($$.u.constant)=IS_LONG; INIT_PZVAL(&$$.u.constant); zend_do_receive_arg(ZEND_RECV, &tmp, &$$, NULL, &$1, &$3, 1 TSRMLS_CC); }
-       |       optional_class_type '&' T_VARIABLE '=' static_scalar                    { znode tmp;  fetch_simple_variable(&tmp, &$3, 0 TSRMLS_CC); $$.op_type = IS_UNUSED; $$.u.op.num=1; Z_TYPE($$.u.constant)=IS_LONG; INIT_PZVAL(&$$.u.constant); zend_do_receive_arg(ZEND_RECV_INIT, &tmp, &$$, &$5, &$1, &$3, 1 TSRMLS_CC); }
-       |       optional_class_type T_VARIABLE '=' static_scalar                                { znode tmp;  fetch_simple_variable(&tmp, &$2, 0 TSRMLS_CC); $$.op_type = IS_UNUSED; $$.u.op.num=1; Z_TYPE($$.u.constant)=IS_LONG; INIT_PZVAL(&$$.u.constant); zend_do_receive_arg(ZEND_RECV_INIT, &tmp, &$$, &$4, &$1, &$2, 0 TSRMLS_CC); }
-       |       non_empty_parameter_list ',' optional_class_type T_VARIABLE     { znode tmp;  fetch_simple_variable(&tmp, &$4, 0 TSRMLS_CC); $$=$1; $$.u.op.num++; zend_do_receive_arg(ZEND_RECV, &tmp, &$$, NULL, &$3, &$4, 0 TSRMLS_CC); }
-       |       non_empty_parameter_list ',' optional_class_type '&' T_VARIABLE { znode tmp;  fetch_simple_variable(&tmp, &$5, 0 TSRMLS_CC); $$=$1; $$.u.op.num++; zend_do_receive_arg(ZEND_RECV, &tmp, &$$, NULL, &$3, &$5, 1 TSRMLS_CC); }
-       |       non_empty_parameter_list ',' optional_class_type '&' T_VARIABLE  '=' static_scalar { znode tmp;  fetch_simple_variable(&tmp, &$5, 0 TSRMLS_CC); $$=$1; $$.u.op.num++; zend_do_receive_arg(ZEND_RECV_INIT, &tmp, &$$, &$7, &$3, &$5, 1 TSRMLS_CC); }
-       |       non_empty_parameter_list ',' optional_class_type T_VARIABLE '=' static_scalar   { znode tmp;  fetch_simple_variable(&tmp, &$4, 0 TSRMLS_CC); $$=$1; $$.u.op.num++; zend_do_receive_arg(ZEND_RECV_INIT, &tmp, &$$, &$6, &$3, &$4, 0 TSRMLS_CC); }
+               optional_class_type T_VARIABLE                          { $$.op_type = IS_UNUSED; $$.u.op.num=1; zend_do_receive_arg(ZEND_RECV, &$2, &$$, NULL, &$1, 0 TSRMLS_CC); }
+       |       optional_class_type '&' T_VARIABLE                      { $$.op_type = IS_UNUSED; $$.u.op.num=1; zend_do_receive_arg(ZEND_RECV, &$3, &$$, NULL, &$1, 1 TSRMLS_CC); }
+       |       optional_class_type '&' T_VARIABLE '=' static_scalar                    { $$.op_type = IS_UNUSED; $$.u.op.num=1; zend_do_receive_arg(ZEND_RECV_INIT, &$3, &$$, &$5, &$1, 1 TSRMLS_CC); }
+       |       optional_class_type T_VARIABLE '=' static_scalar                                { $$.op_type = IS_UNUSED; $$.u.op.num=1; zend_do_receive_arg(ZEND_RECV_INIT, &$2, &$$, &$4, &$1, 0 TSRMLS_CC); }
+       |       non_empty_parameter_list ',' optional_class_type T_VARIABLE     { $$=$1; $$.u.op.num++; zend_do_receive_arg(ZEND_RECV, &$4, &$$, NULL, &$3, 0 TSRMLS_CC); }
+       |       non_empty_parameter_list ',' optional_class_type '&' T_VARIABLE { $$=$1; $$.u.op.num++; zend_do_receive_arg(ZEND_RECV, &$5, &$$, NULL, &$3, 1 TSRMLS_CC); }
+       |       non_empty_parameter_list ',' optional_class_type '&' T_VARIABLE  '=' static_scalar { $$=$1; $$.u.op.num++; zend_do_receive_arg(ZEND_RECV_INIT, &$5, &$$, &$7, &$3, 1 TSRMLS_CC); }
+       |       non_empty_parameter_list ',' optional_class_type T_VARIABLE '=' static_scalar   { $$=$1; $$.u.op.num++; zend_do_receive_arg(ZEND_RECV_INIT, &$4, &$$, &$6, &$3, 0 TSRMLS_CC); }
 ;
 
 
index 243b6dbc68dc1cf5ed1036cf9c3bb086ffb10587..5092f61b8bb9a57b1e87cf8ae0d46f2a63640f1d 100644 (file)
@@ -68,7 +68,7 @@ ZEND_API void zend_objects_store_add_ref(zval *object TSRMLS_DC);
 ZEND_API void zend_objects_store_del_ref(zval *object TSRMLS_DC);
 ZEND_API void zend_objects_store_add_ref_by_handle(zend_object_handle handle TSRMLS_DC);
 ZEND_API void zend_objects_store_del_ref_by_handle_ex(zend_object_handle handle, const zend_object_handlers *handlers TSRMLS_DC);
-static inline void zend_objects_store_del_ref_by_handle(zend_object_handle handle TSRMLS_DC) {
+static zend_always_inline void zend_objects_store_del_ref_by_handle(zend_object_handle handle TSRMLS_DC) {
        zend_objects_store_del_ref_by_handle_ex(handle, NULL TSRMLS_CC);
 }
 ZEND_API zend_uint zend_objects_store_get_refcount(zval *object TSRMLS_DC);
index 901d99f312acdd5bf3aa49f3f1b639c2b67fe35c..affe7d037bfae3e6349a4d65c72c5cc757eabb03 100644 (file)
@@ -54,7 +54,7 @@ END_EXTERN_C()
 
 /*     Not doing this with a macro because of the loop unrolling in the element assignment.
        Just using a macro for 3 in the body for readability sake. */
-static inline void zend_ptr_stack_3_push(zend_ptr_stack *stack, void *a, void *b, void *c)
+static zend_always_inline void zend_ptr_stack_3_push(zend_ptr_stack *stack, void *a, void *b, void *c)
 {
 #define ZEND_PTR_STACK_NUM_ARGS 3
 
@@ -68,7 +68,7 @@ static inline void zend_ptr_stack_3_push(zend_ptr_stack *stack, void *a, void *b
 #undef ZEND_PTR_STACK_NUM_ARGS
 }
 
-static inline void zend_ptr_stack_2_push(zend_ptr_stack *stack, void *a, void *b)
+static zend_always_inline void zend_ptr_stack_2_push(zend_ptr_stack *stack, void *a, void *b)
 {
 #define ZEND_PTR_STACK_NUM_ARGS 2
 
@@ -81,7 +81,7 @@ static inline void zend_ptr_stack_2_push(zend_ptr_stack *stack, void *a, void *b
 #undef ZEND_PTR_STACK_NUM_ARGS
 }
 
-static inline void zend_ptr_stack_3_pop(zend_ptr_stack *stack, void **a, void **b, void **c)
+static zend_always_inline void zend_ptr_stack_3_pop(zend_ptr_stack *stack, void **a, void **b, void **c)
 {
        *a = *(--stack->top_element);
        *b = *(--stack->top_element);
@@ -89,14 +89,14 @@ static inline void zend_ptr_stack_3_pop(zend_ptr_stack *stack, void **a, void **
        stack->top -= 3;
 }
 
-static inline void zend_ptr_stack_2_pop(zend_ptr_stack *stack, void **a, void **b)
+static zend_always_inline void zend_ptr_stack_2_pop(zend_ptr_stack *stack, void **a, void **b)
 {
        *a = *(--stack->top_element);
        *b = *(--stack->top_element);
        stack->top -= 2;
 }
 
-static inline void zend_ptr_stack_push(zend_ptr_stack *stack, void *ptr)
+static zend_always_inline void zend_ptr_stack_push(zend_ptr_stack *stack, void *ptr)
 {
        ZEND_PTR_STACK_RESIZE_IF_NEEDED(stack, 1)
 
@@ -104,7 +104,7 @@ static inline void zend_ptr_stack_push(zend_ptr_stack *stack, void *ptr)
        *(stack->top_element++) = ptr;
 }
 
-static inline void *zend_ptr_stack_pop(zend_ptr_stack *stack)
+static zend_always_inline void *zend_ptr_stack_pop(zend_ptr_stack *stack)
 {
        stack->top--;
        return *(--stack->top_element);
index 9304a67c0e920e6c02ff15002213880b5c0a75d1..87016433337f38f41350729dfcdc887b80437994 100644 (file)
@@ -27,7 +27,7 @@ BEGIN_EXTERN_C()
 
 ZEND_API void _zval_dtor_func(zval *zvalue ZEND_FILE_LINE_DC);
 
-static inline void _zval_dtor(zval *zvalue ZEND_FILE_LINE_DC)
+static zend_always_inline void _zval_dtor(zval *zvalue ZEND_FILE_LINE_DC)
 {
        if (zvalue->type <= IS_BOOL) {
                return;
@@ -37,7 +37,7 @@ static inline void _zval_dtor(zval *zvalue ZEND_FILE_LINE_DC)
 
 ZEND_API void _zval_copy_ctor_func(zval *zvalue ZEND_FILE_LINE_DC);
 
-static inline void _zval_copy_ctor(zval *zvalue ZEND_FILE_LINE_DC)
+static zend_always_inline void _zval_copy_ctor(zval *zvalue ZEND_FILE_LINE_DC)
 {
        if (zvalue->type <= IS_BOOL) {
                return;
index 735c9daaa855c101a319ab3e900df50fb6e4e816..8fb3f855301504124d7ff10040c9971114f63441 100644 (file)
 
 ZEND_VM_HANDLER(1, ZEND_ADD, CONST|TMP|VAR|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        add_function(&EX_T(opline->result.var).tmp_var,
                GET_OP1_ZVAL_PTR(BP_VAR_R),
                GET_OP2_ZVAL_PTR(BP_VAR_R) TSRMLS_CC);
        FREE_OP1();
        FREE_OP2();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(2, ZEND_SUB, CONST|TMP|VAR|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        sub_function(&EX_T(opline->result.var).tmp_var,
                GET_OP1_ZVAL_PTR(BP_VAR_R),
                GET_OP2_ZVAL_PTR(BP_VAR_R) TSRMLS_CC);
        FREE_OP1();
        FREE_OP2();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(3, ZEND_MUL, CONST|TMP|VAR|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        mul_function(&EX_T(opline->result.var).tmp_var,
                GET_OP1_ZVAL_PTR(BP_VAR_R),
                GET_OP2_ZVAL_PTR(BP_VAR_R) TSRMLS_CC);
        FREE_OP1();
        FREE_OP2();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(4, ZEND_DIV, CONST|TMP|VAR|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        div_function(&EX_T(opline->result.var).tmp_var,
                GET_OP1_ZVAL_PTR(BP_VAR_R),
                GET_OP2_ZVAL_PTR(BP_VAR_R) TSRMLS_CC);
        FREE_OP1();
        FREE_OP2();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(5, ZEND_MOD, CONST|TMP|VAR|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        mod_function(&EX_T(opline->result.var).tmp_var,
                GET_OP1_ZVAL_PTR(BP_VAR_R),
                GET_OP2_ZVAL_PTR(BP_VAR_R) TSRMLS_CC);
        FREE_OP1();
        FREE_OP2();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(6, ZEND_SL, CONST|TMP|VAR|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        shift_left_function(&EX_T(opline->result.var).tmp_var,
                GET_OP1_ZVAL_PTR(BP_VAR_R),
                GET_OP2_ZVAL_PTR(BP_VAR_R) TSRMLS_CC);
        FREE_OP1();
        FREE_OP2();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(7, ZEND_SR, CONST|TMP|VAR|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        shift_right_function(&EX_T(opline->result.var).tmp_var,
                GET_OP1_ZVAL_PTR(BP_VAR_R),
                GET_OP2_ZVAL_PTR(BP_VAR_R) TSRMLS_CC);
        FREE_OP1();
        FREE_OP2();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(8, ZEND_CONCAT, CONST|TMP|VAR|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        concat_function(&EX_T(opline->result.var).tmp_var,
                GET_OP1_ZVAL_PTR(BP_VAR_R),
                GET_OP2_ZVAL_PTR(BP_VAR_R) TSRMLS_CC);
        FREE_OP1();
        FREE_OP2();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(15, ZEND_IS_IDENTICAL, CONST|TMP|VAR|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        is_identical_function(&EX_T(opline->result.var).tmp_var,
                GET_OP1_ZVAL_PTR(BP_VAR_R),
                GET_OP2_ZVAL_PTR(BP_VAR_R) TSRMLS_CC);
        FREE_OP1();
        FREE_OP2();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(16, ZEND_IS_NOT_IDENTICAL, CONST|TMP|VAR|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        is_identical_function(result,
                GET_OP1_ZVAL_PTR(BP_VAR_R),
                GET_OP2_ZVAL_PTR(BP_VAR_R) TSRMLS_CC);
        Z_LVAL_P(result) = !Z_LVAL_P(result);
        FREE_OP1();
        FREE_OP2();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(17, ZEND_IS_EQUAL, CONST|TMP|VAR|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
                GET_OP1_ZVAL_PTR(BP_VAR_R),
                GET_OP2_ZVAL_PTR(BP_VAR_R) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) == 0));
        FREE_OP1();
        FREE_OP2();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(18, ZEND_IS_NOT_EQUAL, CONST|TMP|VAR|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
                GET_OP1_ZVAL_PTR(BP_VAR_R),
                GET_OP2_ZVAL_PTR(BP_VAR_R) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) != 0));
        FREE_OP1();
        FREE_OP2();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(19, ZEND_IS_SMALLER, CONST|TMP|VAR|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
                GET_OP1_ZVAL_PTR(BP_VAR_R),
                GET_OP2_ZVAL_PTR(BP_VAR_R) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) < 0));
        FREE_OP1();
        FREE_OP2();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(20, ZEND_IS_SMALLER_OR_EQUAL, CONST|TMP|VAR|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
                GET_OP1_ZVAL_PTR(BP_VAR_R),
                GET_OP2_ZVAL_PTR(BP_VAR_R) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) <= 0));
        FREE_OP1();
        FREE_OP2();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(9, ZEND_BW_OR, CONST|TMP|VAR|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        bitwise_or_function(&EX_T(opline->result.var).tmp_var,
                GET_OP1_ZVAL_PTR(BP_VAR_R),
                GET_OP2_ZVAL_PTR(BP_VAR_R) TSRMLS_CC);
        FREE_OP1();
        FREE_OP2();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(10, ZEND_BW_AND, CONST|TMP|VAR|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        bitwise_and_function(&EX_T(opline->result.var).tmp_var,
                GET_OP1_ZVAL_PTR(BP_VAR_R),
                GET_OP2_ZVAL_PTR(BP_VAR_R) TSRMLS_CC);
        FREE_OP1();
        FREE_OP2();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(11, ZEND_BW_XOR, CONST|TMP|VAR|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        bitwise_xor_function(&EX_T(opline->result.var).tmp_var,
                GET_OP1_ZVAL_PTR(BP_VAR_R),
                GET_OP2_ZVAL_PTR(BP_VAR_R) TSRMLS_CC);
        FREE_OP1();
        FREE_OP2();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(14, ZEND_BOOL_XOR, CONST|TMP|VAR|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        boolean_xor_function(&EX_T(opline->result.var).tmp_var,
                GET_OP1_ZVAL_PTR(BP_VAR_R),
                GET_OP2_ZVAL_PTR(BP_VAR_R) TSRMLS_CC);
        FREE_OP1();
        FREE_OP2();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(12, ZEND_BW_NOT, CONST|TMP|VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        bitwise_not_function(&EX_T(opline->result.var).tmp_var,
                GET_OP1_ZVAL_PTR(BP_VAR_R) TSRMLS_CC);
        FREE_OP1();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(13, ZEND_BOOL_NOT, CONST|TMP|VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        boolean_not_function(&EX_T(opline->result.var).tmp_var,
                GET_OP1_ZVAL_PTR(BP_VAR_R) TSRMLS_CC);
        FREE_OP1();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HELPER_EX(zend_binary_assign_op_obj_helper, VAR|UNUSED|CV, CONST|TMP|VAR|UNUSED|CV, int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC))
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op1, free_op2, free_op_data1;
        zval **object_ptr = GET_OP1_OBJ_ZVAL_PTR_PTR(BP_VAR_W);
        zval *object;
        zval *property = GET_OP2_ZVAL_PTR(BP_VAR_R);
-       zval *value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
+       zval *value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
        znode_op *result = &opline->result;
        int have_get_ptr = 0;
 
-       if (OP1_TYPE == IS_VAR && !object_ptr) {
+       if (OP1_TYPE == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
 
-       EX_T(result->var).var.ptr_ptr = NULL;
        make_real_object(object_ptr TSRMLS_CC);
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to assign property of non-object");
                FREE_OP2();
                FREE_OP(free_op_data1);
 
                if (RETURN_VALUE_USED(opline)) {
-                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                       EX_T(result->var).var.ptr_ptr = NULL;
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                }
        } else {
                /* here we are sure we are dealing with an object */
@@ -337,9 +375,9 @@ ZEND_VM_HELPER_EX(zend_binary_assign_op_obj_helper, VAR|UNUSED|CV, CONST|TMP|VAR
                                have_get_ptr = 1;
                                binary_op(*zptr, *zptr, value TSRMLS_CC);
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = *zptr;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(*zptr);
+                                       EX_T(opline->result.var).var.ptr = *zptr;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -376,17 +414,17 @@ ZEND_VM_HELPER_EX(zend_binary_assign_op_obj_helper, VAR|UNUSED|CV, CONST|TMP|VAR
                                        Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
                                }
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = z;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(z);
+                                       EX_T(opline->result.var).var.ptr = z;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                                zval_ptr_dtor(&z);
                        } else {
                                zend_error(E_WARNING, "Attempt to assign property of non-object");
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                                       EX_T(result->var).var.ptr_ptr = NULL;
-                                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                                       PZVAL_LOCK(&EG(uninitialized_zval));
+                                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -401,17 +439,19 @@ ZEND_VM_HELPER_EX(zend_binary_assign_op_obj_helper, VAR|UNUSED|CV, CONST|TMP|VAR
 
        FREE_OP1_VAR_PTR();
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HELPER_EX(zend_binary_assign_op_helper, VAR|UNUSED|CV, CONST|TMP|VAR|UNUSED|CV, int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC))
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2, free_op_data2, free_op_data1;
        zval **var_ptr;
        zval *value;
 
+       SAVE_OPLINE();
        switch (opline->extended_value) {
                case ZEND_ASSIGN_OBJ:
                        ZEND_VM_DISPATCH_TO_HELPER_EX(zend_binary_assign_op_obj_helper, binary_op, binary_op);
@@ -419,21 +459,19 @@ ZEND_VM_HELPER_EX(zend_binary_assign_op_helper, VAR|UNUSED|CV, CONST|TMP|VAR|UNU
                case ZEND_ASSIGN_DIM: {
                                zval **container = GET_OP1_OBJ_ZVAL_PTR_PTR(BP_VAR_RW);
 
-                               if (OP1_TYPE == IS_VAR && !container) {
+                               if (OP1_TYPE == IS_VAR && UNEXPECTED(container == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-                               } else if (Z_TYPE_PP(container) == IS_OBJECT) {
+                               } else if (UNEXPECTED(Z_TYPE_PP(container) == IS_OBJECT)) {
                                        if (OP1_TYPE == IS_VAR && !OP1_FREE) {
                                                Z_ADDREF_PP(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
                                        }
                                        ZEND_VM_DISPATCH_TO_HELPER_EX(zend_binary_assign_op_obj_helper, binary_op, binary_op);
                                } else {
-                                       zend_op *op_data = opline+1;
                                        zval *dim = GET_OP2_ZVAL_PTR(BP_VAR_R);
 
-                                       zend_fetch_dimension_address(&EX_T(op_data->op2.var), container, dim, OP2_TYPE, BP_VAR_RW TSRMLS_CC);
-                                       value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-                                       var_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-                                       ZEND_VM_INC_OPCODE();
+                                       zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), container, dim, OP2_TYPE, BP_VAR_RW TSRMLS_CC);
+                                       value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+                                       var_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
                                }
                        }
                        break;
@@ -444,23 +482,28 @@ ZEND_VM_HELPER_EX(zend_binary_assign_op_helper, VAR|UNUSED|CV, CONST|TMP|VAR|UNU
                        break;
        }
 
-       if (!var_ptr) {
+       if (UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
        }
 
-       if (*var_ptr == EG(error_zval_ptr)) {
+       if (UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
                FREE_OP2();
                FREE_OP1_VAR_PTR();
+               CHECK_EXCEPTION();
+               if (opline->extended_value == ZEND_ASSIGN_DIM) {
+                       ZEND_VM_INC_OPCODE();
+               }
                ZEND_VM_NEXT_OPCODE();
        }
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *objval = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -473,16 +516,21 @@ ZEND_VM_HELPER_EX(zend_binary_assign_op_helper, VAR|UNUSED|CV, CONST|TMP|VAR|UNU
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *var_ptr);
                PZVAL_LOCK(*var_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *var_ptr);
        }
        FREE_OP2();
 
        if (opline->extended_value == ZEND_ASSIGN_DIM) {
                FREE_OP(free_op_data1);
                FREE_OP_VAR_PTR(free_op_data2);
+               FREE_OP1_VAR_PTR();
+               CHECK_EXCEPTION();
+               ZEND_VM_INC_OPCODE();
+       } else {
+               FREE_OP1_VAR_PTR();
+               CHECK_EXCEPTION();
        }
-       FREE_OP1_VAR_PTR();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -543,29 +591,35 @@ ZEND_VM_HANDLER(33, ZEND_ASSIGN_BW_XOR, VAR|UNUSED|CV, CONST|TMP|VAR|UNUSED|CV)
 
 ZEND_VM_HELPER_EX(zend_pre_incdec_property_helper, VAR|UNUSED|CV, CONST|TMP|VAR|CV, incdec_t incdec_op)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval **object_ptr = GET_OP1_OBJ_ZVAL_PTR_PTR(BP_VAR_W);
+       zval **object_ptr;
        zval *object;
-       zval *property = GET_OP2_ZVAL_PTR(BP_VAR_R);
-       zval **retval = &EX_T(opline->result.var).var.ptr;
+       zval *property;
+       zval **retval;
        int have_get_ptr = 0;
 
-       if (OP1_TYPE == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = GET_OP1_OBJ_ZVAL_PTR_PTR(BP_VAR_W);
+       property = GET_OP2_ZVAL_PTR(BP_VAR_R);
+       retval = &EX_T(opline->result.var).var.ptr;
+
+       if (OP1_TYPE == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                FREE_OP2();
                if (RETURN_VALUE_USED(opline)) {
-                       *retval = EG(uninitialized_zval_ptr);
-                       PZVAL_LOCK(*retval);
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       *retval = &EG(uninitialized_zval);
                }
                FREE_OP1_VAR_PTR();
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -593,7 +647,7 @@ ZEND_VM_HELPER_EX(zend_pre_incdec_property_helper, VAR|UNUSED|CV, CONST|TMP|VAR|
                if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((OP2_TYPE == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -613,8 +667,8 @@ ZEND_VM_HELPER_EX(zend_pre_incdec_property_helper, VAR|UNUSED|CV, CONST|TMP|VAR|
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                        if (RETURN_VALUE_USED(opline)) {
-                               *retval = EG(uninitialized_zval_ptr);
-                               PZVAL_LOCK(*retval);
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               *retval = &EG(uninitialized_zval);
                        }
                }
        }
@@ -625,6 +679,7 @@ ZEND_VM_HELPER_EX(zend_pre_incdec_property_helper, VAR|UNUSED|CV, CONST|TMP|VAR|
                FREE_OP2();
        }
        FREE_OP1_VAR_PTR();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -640,26 +695,32 @@ ZEND_VM_HANDLER(133, ZEND_PRE_DEC_OBJ, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
 
 ZEND_VM_HELPER_EX(zend_post_incdec_property_helper, VAR|UNUSED|CV, CONST|TMP|VAR|CV, incdec_t incdec_op)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval **object_ptr = GET_OP1_OBJ_ZVAL_PTR_PTR(BP_VAR_W);
+       zval **object_ptr;
        zval *object;
-       zval *property = GET_OP2_ZVAL_PTR(BP_VAR_R);
-       zval *retval = &EX_T(opline->result.var).tmp_var;
+       zval *property;
+       zval *retval;
        int have_get_ptr = 0;
 
-       if (OP1_TYPE == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = GET_OP1_OBJ_ZVAL_PTR_PTR(BP_VAR_W);
+       property = GET_OP2_ZVAL_PTR(BP_VAR_R);
+       retval = &EX_T(opline->result.var).tmp_var;
+
+       if (OP1_TYPE == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                FREE_OP2();
-               *retval = *EG(uninitialized_zval_ptr);
+               ZVAL_NULL(retval);
                FREE_OP1_VAR_PTR();
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -675,7 +736,7 @@ ZEND_VM_HELPER_EX(zend_post_incdec_property_helper, VAR|UNUSED|CV, CONST|TMP|VAR
                        have_get_ptr = 1;
                        SEPARATE_ZVAL_IF_NOT_REF(zptr);
 
-                       *retval = **zptr;
+                       ZVAL_COPY_VALUE(retval, *zptr);
                        zendi_zval_copy_ctor(*retval);
 
                        incdec_op(*zptr);
@@ -688,7 +749,7 @@ ZEND_VM_HELPER_EX(zend_post_incdec_property_helper, VAR|UNUSED|CV, CONST|TMP|VAR
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((OP2_TYPE == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
                        zval *z_copy;
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -698,12 +759,11 @@ ZEND_VM_HELPER_EX(zend_post_incdec_property_helper, VAR|UNUSED|CV, CONST|TMP|VAR
                                }
                                z = value;
                        }
-                       *retval = *z;
+                       ZVAL_COPY_VALUE(retval, z);
                        zendi_zval_copy_ctor(*retval);
                        ALLOC_ZVAL(z_copy);
-                       *z_copy = *z;
+                       INIT_PZVAL_COPY(z_copy, z);
                        zendi_zval_copy_ctor(*z_copy);
-                       INIT_PZVAL(z_copy);
                        incdec_op(z_copy);
                        Z_ADDREF_P(z);
                        Z_OBJ_HT_P(object)->write_property(object, property, z_copy, ((OP2_TYPE == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
@@ -711,7 +771,7 @@ ZEND_VM_HELPER_EX(zend_post_incdec_property_helper, VAR|UNUSED|CV, CONST|TMP|VAR
                        zval_ptr_dtor(&z);
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-                       *retval = *EG(uninitialized_zval_ptr);
+                       ZVAL_NULL(retval);
                }
        }
 
@@ -721,6 +781,7 @@ ZEND_VM_HELPER_EX(zend_post_incdec_property_helper, VAR|UNUSED|CV, CONST|TMP|VAR
                FREE_OP2();
        }
        FREE_OP1_VAR_PTR();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -736,25 +797,30 @@ ZEND_VM_HANDLER(135, ZEND_POST_DEC_OBJ, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
 
 ZEND_VM_HANDLER(34, ZEND_PRE_INC, VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **var_ptr = GET_OP1_ZVAL_PTR_PTR(BP_VAR_RW);
+       zval **var_ptr;
 
-       if (OP1_TYPE == IS_VAR && !var_ptr) {
+       SAVE_OPLINE();
+       var_ptr = GET_OP1_ZVAL_PTR_PTR(BP_VAR_RW);
+
+       if (OP1_TYPE == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
-       if (OP1_TYPE == IS_VAR && *var_ptr == EG(error_zval_ptr)) {
+       if (OP1_TYPE == IS_VAR && UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
                FREE_OP1_VAR_PTR();
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *val = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -767,35 +833,41 @@ ZEND_VM_HANDLER(34, ZEND_PRE_INC, VAR|CV, ANY)
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *var_ptr);
                PZVAL_LOCK(*var_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *var_ptr);
        }
 
        FREE_OP1_VAR_PTR();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(35, ZEND_PRE_DEC, VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **var_ptr = GET_OP1_ZVAL_PTR_PTR(BP_VAR_RW);
+       zval **var_ptr;
 
-       if (OP1_TYPE == IS_VAR && !var_ptr) {
+       SAVE_OPLINE();
+       var_ptr = GET_OP1_ZVAL_PTR_PTR(BP_VAR_RW);
+
+       if (OP1_TYPE == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
-       if (OP1_TYPE == IS_VAR && *var_ptr == EG(error_zval_ptr)) {
+       if (OP1_TYPE == IS_VAR && UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
                FREE_OP1_VAR_PTR();
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *val = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -808,37 +880,44 @@ ZEND_VM_HANDLER(35, ZEND_PRE_DEC, VAR|CV, ANY)
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *var_ptr);
                PZVAL_LOCK(*var_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *var_ptr);
        }
 
        FREE_OP1_VAR_PTR();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(36, ZEND_POST_INC, VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **var_ptr = GET_OP1_ZVAL_PTR_PTR(BP_VAR_RW);
+       zval **var_ptr, *retval;
+
+       SAVE_OPLINE();
+       var_ptr = GET_OP1_ZVAL_PTR_PTR(BP_VAR_RW);
 
-       if (OP1_TYPE == IS_VAR && !var_ptr) {
+       if (OP1_TYPE == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
-       if (OP1_TYPE == IS_VAR && *var_ptr == EG(error_zval_ptr)) {
+       if (OP1_TYPE == IS_VAR && UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       EX_T(opline->result.var).tmp_var = *EG(uninitialized_zval_ptr);
+                       ZVAL_NULL(&EX_T(opline->result.var).tmp_var);
                }
                FREE_OP1_VAR_PTR();
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
-       EX_T(opline->result.var).tmp_var = **var_ptr;
-       zendi_zval_copy_ctor(EX_T(opline->result.var).tmp_var);
+       retval = &EX_T(opline->result.var).tmp_var;
+       ZVAL_COPY_VALUE(retval, *var_ptr);
+       zendi_zval_copy_ctor(*retval);
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *val = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -851,32 +930,39 @@ ZEND_VM_HANDLER(36, ZEND_POST_INC, VAR|CV, ANY)
        }
 
        FREE_OP1_VAR_PTR();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(37, ZEND_POST_DEC, VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **var_ptr = GET_OP1_ZVAL_PTR_PTR(BP_VAR_RW);
+       zval **var_ptr, *retval;
 
-       if (OP1_TYPE == IS_VAR && !var_ptr) {
+       SAVE_OPLINE();
+       var_ptr = GET_OP1_ZVAL_PTR_PTR(BP_VAR_RW);
+
+       if (OP1_TYPE == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
-       if (OP1_TYPE == IS_VAR && *var_ptr == EG(error_zval_ptr)) {
+       if (OP1_TYPE == IS_VAR && UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       EX_T(opline->result.var).tmp_var = *EG(uninitialized_zval_ptr);
+                       ZVAL_NULL(&EX_T(opline->result.var).tmp_var);
                }
                FREE_OP1_VAR_PTR();
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
-       EX_T(opline->result.var).tmp_var = **var_ptr;
-       zendi_zval_copy_ctor(EX_T(opline->result.var).tmp_var);
+       retval = &EX_T(opline->result.var).tmp_var;
+       ZVAL_COPY_VALUE(retval, *var_ptr);
+       zendi_zval_copy_ctor(*retval);
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *val = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -889,18 +975,23 @@ ZEND_VM_HANDLER(37, ZEND_POST_DEC, VAR|CV, ANY)
        }
 
        FREE_OP1_VAR_PTR();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(40, ZEND_ECHO, CONST|TMP|VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval z_copy;
-       zval *z = GET_OP1_ZVAL_PTR(BP_VAR_R);
+       zval *z;
+
+       SAVE_OPLINE();
+       z = GET_OP1_ZVAL_PTR(BP_VAR_R);
 
        if (OP1_TYPE != IS_CONST &&
-           Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get_method != NULL &&
+           UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) &&
+           Z_OBJ_HT_P(z)->get_method != NULL &&
                zend_std_cast_object_tostring(z, &z_copy, IS_STRING TSRMLS_CC) == SUCCESS) {
                zend_print_variable(&z_copy);
                zval_dtor(&z_copy);
@@ -909,31 +1000,33 @@ ZEND_VM_HANDLER(40, ZEND_ECHO, CONST|TMP|VAR|CV, ANY)
        }
 
        FREE_OP1();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(41, ZEND_PRINT, CONST|TMP|VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
-
-       Z_LVAL(EX_T(opline->result.var).tmp_var) = 1;
-       Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_LONG;
+       USE_OPLINE
 
+       ZVAL_LONG(&EX_T(opline->result.var).tmp_var, 1);
        ZEND_VM_DISPATCH_TO_HANDLER(ZEND_ECHO);
 }
 
 ZEND_VM_HELPER_EX(zend_fetch_var_address_helper, CONST|TMP|VAR|CV, ANY, int type)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *varname = GET_OP1_ZVAL_PTR(BP_VAR_R);
+       zval *varname;
        zval **retval;
        zval tmp_varname;
        HashTable *target_symbol_table;
        ulong hash_value;
 
-       if (OP1_TYPE != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-               tmp_varname = *varname;
+       SAVE_OPLINE();
+       varname = GET_OP1_ZVAL_PTR(BP_VAR_R);
+
+       if (OP1_TYPE != IS_CONST && UNEXPECTED(Z_TYPE_P(varname) != IS_STRING)) {
+               ZVAL_COPY_VALUE(&tmp_varname, varname);
                zval_copy_ctor(&tmp_varname);
                convert_to_string(&tmp_varname);
                varname = &tmp_varname;
@@ -946,6 +1039,7 @@ ZEND_VM_HELPER_EX(zend_fetch_var_address_helper, CONST|TMP|VAR|CV, ANY, int type
                target_symbol_table = zend_get_target_symbol_table(opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
 /*
                if (!target_symbol_table) {
+                       CHECK_EXCEPTION();
                        ZEND_VM_NEXT_OPCODE();
                }
 */
@@ -969,12 +1063,9 @@ ZEND_VM_HELPER_EX(zend_fetch_var_address_helper, CONST|TMP|VAR|CV, ANY, int type
                                case BP_VAR_RW:
                                        zend_error(E_NOTICE,"Undefined variable: %s", Z_STRVAL_P(varname));
                                        /* break missing intentionally */
-                               case BP_VAR_W: {
-                                               zval *new_zval = &EG(uninitialized_zval);
-
-                                               Z_ADDREF_P(new_zval);
-                                               zend_hash_quick_update(target_symbol_table, Z_STRVAL_P(varname), Z_STRLEN_P(varname)+1, hash_value, &new_zval, sizeof(zval *), (void **) &retval);
-                                       }
+                               case BP_VAR_W:
+                                       Z_ADDREF_P(&EG(uninitialized_zval));
+                                       zend_hash_quick_update(target_symbol_table, Z_STRVAL_P(varname), Z_STRLEN_P(varname)+1, hash_value, &EG(uninitialized_zval_ptr), sizeof(zval *), (void **) &retval);
                                        break;
                                EMPTY_SWITCH_DEFAULT_CASE()
                        }
@@ -1001,7 +1092,7 @@ ZEND_VM_HELPER_EX(zend_fetch_var_address_helper, CONST|TMP|VAR|CV, ANY, int type
 
 
        if (OP1_TYPE != IS_CONST && varname == &tmp_varname) {
-               zval_dtor(varname);
+               zval_dtor(&tmp_varname);
        }
        if (RETURN_VALUE_USED(opline)) {
                if (opline->extended_value & ZEND_FETCH_MAKE_REF) {
@@ -1011,25 +1102,25 @@ ZEND_VM_HELPER_EX(zend_fetch_var_address_helper, CONST|TMP|VAR|CV, ANY, int type
                switch (type) {
                        case BP_VAR_R:
                        case BP_VAR_IS:
-                               AI_SET_PTR(EX_T(opline->result.var).var, *retval);
+                               AI_SET_PTR(&EX_T(opline->result.var), *retval);
                                break;
                        case BP_VAR_UNSET: {
                                zend_free_op free_res;
 
-                               EX_T(opline->result.var).var.ptr_ptr = retval;
-                               PZVAL_UNLOCK(*EX_T(opline->result.var).var.ptr_ptr, &free_res);
-                               if (EX_T(opline->result.var).var.ptr_ptr != &EG(uninitialized_zval_ptr)) {
-                                       SEPARATE_ZVAL_IF_NOT_REF(EX_T(opline->result.var).var.ptr_ptr);
+                               PZVAL_UNLOCK(*retval, &free_res);
+                               if (retval != &EG(uninitialized_zval_ptr)) {
+                                       SEPARATE_ZVAL_IF_NOT_REF(retval);
                                }
-                               PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
+                               PZVAL_LOCK(*retval);
                                FREE_OP_VAR_PTR(free_res);
-                               break;
+                       }
+                       /* break missing intentionally */
                        default:
                                EX_T(opline->result.var).var.ptr_ptr = retval;
                                break;
-                       }
                }
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -1050,8 +1141,10 @@ ZEND_VM_HANDLER(86, ZEND_FETCH_RW, CONST|TMP|VAR|CV, ANY)
 
 ZEND_VM_HANDLER(92, ZEND_FETCH_FUNC_ARG, CONST|TMP|VAR|CV, ANY)
 {
+       USE_OPLINE
+
        ZEND_VM_DISPATCH_TO_HELPER_EX(zend_fetch_var_address_helper, type,
-               ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (EX(opline)->extended_value & ZEND_FETCH_ARG_MASK))?BP_VAR_W:BP_VAR_R);
+               ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))?BP_VAR_W:BP_VAR_R);
 }
 
 ZEND_VM_HANDLER(95, ZEND_FETCH_UNSET, CONST|TMP|VAR|CV, ANY)
@@ -1066,195 +1159,194 @@ ZEND_VM_HANDLER(89, ZEND_FETCH_IS, CONST|TMP|VAR|CV, ANY)
 
 ZEND_VM_HANDLER(81, ZEND_FETCH_DIM_R, VAR|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *dim = GET_OP2_ZVAL_PTR(BP_VAR_R);
        zval **container;
 
+       SAVE_OPLINE();
+
        if ((opline->extended_value & ZEND_FETCH_ADD_LOCK) &&
            OP1_TYPE != IS_CV &&
            EX_T(opline->op1.var).var.ptr_ptr) {
                PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
        }
        container = GET_OP1_ZVAL_PTR_PTR(BP_VAR_R);
-       if (OP1_TYPE == IS_VAR && !container) {
+       if (OP1_TYPE == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address_read(!RETURN_VALUE_USED(opline)?NULL:&EX_T(opline->result.var), container, dim, OP2_TYPE, BP_VAR_R TSRMLS_CC);
+       zend_fetch_dimension_address_read(!RETURN_VALUE_USED(opline)?NULL:&EX_T(opline->result.var), container, GET_OP2_ZVAL_PTR(BP_VAR_R), OP2_TYPE, BP_VAR_R TSRMLS_CC);
        FREE_OP2();
        FREE_OP1_VAR_PTR();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(84, ZEND_FETCH_DIM_W, VAR|CV, CONST|TMP|VAR|UNUSED|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *dim = GET_OP2_ZVAL_PTR(BP_VAR_R);
-       zval **container = GET_OP1_ZVAL_PTR_PTR(BP_VAR_W);
+       zval **container;
 
-       if (OP1_TYPE == IS_VAR && !container) {
+       SAVE_OPLINE();
+       container = GET_OP1_ZVAL_PTR_PTR(BP_VAR_W);
+
+       if (OP1_TYPE == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, OP2_TYPE, BP_VAR_W TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, GET_OP2_ZVAL_PTR(BP_VAR_R), OP2_TYPE, BP_VAR_W TSRMLS_CC);
        FREE_OP2();
-       if (OP1_TYPE == IS_VAR && OP1_FREE &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (OP1_TYPE == IS_VAR && OP1_FREE && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        FREE_OP1_VAR_PTR();
 
        /* We are going to assign the result by reference */
-       if (opline->extended_value && EX_T(opline->result.var).var.ptr_ptr) {
-               Z_DELREF_PP(EX_T(opline->result.var).var.ptr_ptr);
-               SEPARATE_ZVAL_TO_MAKE_IS_REF(EX_T(opline->result.var).var.ptr_ptr);
-               Z_ADDREF_PP(EX_T(opline->result.var).var.ptr_ptr);
+       if (UNEXPECTED(opline->extended_value != 0)) {
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+               
+               if (retval_ptr) {
+                       Z_DELREF_PP(retval_ptr);
+                       SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
+                       Z_ADDREF_PP(retval_ptr);
+               }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(87, ZEND_FETCH_DIM_RW, VAR|CV, CONST|TMP|VAR|UNUSED|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *dim = GET_OP2_ZVAL_PTR(BP_VAR_R);
-       zval **container = GET_OP1_ZVAL_PTR_PTR(BP_VAR_RW);
+       zval **container;
+
+       SAVE_OPLINE();
+       container = GET_OP1_ZVAL_PTR_PTR(BP_VAR_RW);
 
-       if (OP1_TYPE == IS_VAR && !container) {
+       if (OP1_TYPE == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, OP2_TYPE, BP_VAR_RW TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, GET_OP2_ZVAL_PTR(BP_VAR_R), OP2_TYPE, BP_VAR_RW TSRMLS_CC);
        FREE_OP2();
-       if (OP1_TYPE == IS_VAR && OP1_FREE &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (OP1_TYPE == IS_VAR && OP1_FREE && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        FREE_OP1_VAR_PTR();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(90, ZEND_FETCH_DIM_IS, VAR|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *dim = GET_OP2_ZVAL_PTR(BP_VAR_R);
-       zval **container = GET_OP1_ZVAL_PTR_PTR(BP_VAR_IS);
+       zval **container;
+
+       SAVE_OPLINE();
+       container = GET_OP1_ZVAL_PTR_PTR(BP_VAR_IS);
 
-       if (OP1_TYPE == IS_VAR && !container) {
+       if (OP1_TYPE == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, dim, OP2_TYPE, BP_VAR_IS TSRMLS_CC);
+       zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, GET_OP2_ZVAL_PTR(BP_VAR_R), OP2_TYPE, BP_VAR_IS TSRMLS_CC);
        FREE_OP2();
        FREE_OP1_VAR_PTR();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(93, ZEND_FETCH_DIM_FUNC_ARG, VAR|CV, CONST|TMP|VAR|UNUSED|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *dim = GET_OP2_ZVAL_PTR(BP_VAR_R);
        zval **container;
 
+       SAVE_OPLINE();
+
        if (ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))) {
                container = GET_OP1_ZVAL_PTR_PTR(BP_VAR_W);
-               if (OP1_TYPE == IS_VAR && !container) {
+               if (OP1_TYPE == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, OP2_TYPE, BP_VAR_W TSRMLS_CC);
-               if (OP1_TYPE == IS_VAR && OP1_FREE &&
-                   READY_TO_DESTROY(free_op1.var)) {
-                       AI_USE_PTR(EX_T(opline->result.var).var);
-                       if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                           Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                               SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-                       }
+               zend_fetch_dimension_address(&EX_T(opline->result.var), container, GET_OP2_ZVAL_PTR(BP_VAR_R), OP2_TYPE, BP_VAR_W TSRMLS_CC);
+               if (OP1_TYPE == IS_VAR && OP1_FREE && READY_TO_DESTROY(free_op1.var)) {
+                       EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
                }
        } else {
                if (OP2_TYPE == IS_UNUSED) {
                        zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
                }
                container = GET_OP1_ZVAL_PTR_PTR(BP_VAR_R);
-               if (OP1_TYPE == IS_VAR && !container) {
+               if (OP1_TYPE == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, dim, OP2_TYPE, BP_VAR_R TSRMLS_CC);
+               zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, GET_OP2_ZVAL_PTR(BP_VAR_R), OP2_TYPE, BP_VAR_R TSRMLS_CC);
        }
        FREE_OP2();
        FREE_OP1_VAR_PTR();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(96, ZEND_FETCH_DIM_UNSET, VAR|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval **container = GET_OP1_ZVAL_PTR_PTR(BP_VAR_UNSET);
-       zval *dim = GET_OP2_ZVAL_PTR(BP_VAR_R);
+       zval **container;
+
+       SAVE_OPLINE();
+       container = GET_OP1_ZVAL_PTR_PTR(BP_VAR_UNSET);
 
-       /* Not needed in DIM_UNSET
-       if (opline->extended_value & ZEND_FETCH_ADD_LOCK) {
-               PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
-       }
-       */
        if (OP1_TYPE == IS_CV) {
                if (container != &EG(uninitialized_zval_ptr)) {
                        SEPARATE_ZVAL_IF_NOT_REF(container);
                }
        }
-       if (OP1_TYPE == IS_VAR && !container) {
+       if (OP1_TYPE == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, OP2_TYPE, BP_VAR_UNSET TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, GET_OP2_ZVAL_PTR(BP_VAR_R), OP2_TYPE, BP_VAR_UNSET TSRMLS_CC);
        FREE_OP2();
-       if (OP1_TYPE == IS_VAR && OP1_FREE &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (OP1_TYPE == IS_VAR && OP1_FREE && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        FREE_OP1_VAR_PTR();
-       if (EX_T(opline->result.var).var.ptr_ptr == NULL) {
+       if (UNEXPECTED(EX_T(opline->result.var).var.ptr_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
        } else {
                zend_free_op free_res;
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
 
-               PZVAL_UNLOCK(*EX_T(opline->result.var).var.ptr_ptr, &free_res);
-               if (EX_T(opline->result.var).var.ptr_ptr != &EG(uninitialized_zval_ptr)) {
-                       SEPARATE_ZVAL_IF_NOT_REF(EX_T(opline->result.var).var.ptr_ptr);
+               PZVAL_UNLOCK(*retval_ptr, &free_res);
+               if (retval_ptr != &EG(uninitialized_zval_ptr)) {
+                       SEPARATE_ZVAL_IF_NOT_REF(retval_ptr);
                }
-               PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
+               PZVAL_LOCK(*retval_ptr);
                FREE_OP_VAR_PTR(free_res);
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
        }
-       ZEND_VM_NEXT_OPCODE();
 }
 
-ZEND_VM_HELPER_EX(zend_fetch_property_address_read_helper, VAR|UNUSED|CV, CONST|TMP|VAR|CV, int type)
+ZEND_VM_HELPER(zend_fetch_property_address_read_helper, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *container = GET_OP1_OBJ_ZVAL_PTR(type);
+       zval *container;
        zend_free_op free_op2;
-       zval *offset  = GET_OP2_ZVAL_PTR(BP_VAR_R);
+       zval *offset;
 
-       if (Z_TYPE_P(container) != IS_OBJECT || !Z_OBJ_HT_P(container)->read_property) {
-               if (type != BP_VAR_IS) {
-                       zend_error(E_NOTICE, "Trying to get property of non-object");
-               }
+       SAVE_OPLINE();
+       container = GET_OP1_OBJ_ZVAL_PTR(BP_VAR_R);
+       offset  = GET_OP2_ZVAL_PTR(BP_VAR_R);
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               zend_error(E_NOTICE, "Trying to get property of non-object");
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
                FREE_OP2();
        } else {
@@ -1265,7 +1357,7 @@ ZEND_VM_HELPER_EX(zend_fetch_property_address_read_helper, VAR|UNUSED|CV, CONST|
                }
 
                /* here we are sure we are dealing with an object */
-               retval = Z_OBJ_HT_P(container)->read_property(container, offset, type, ((OP2_TYPE == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((OP2_TYPE == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
                if (!RETURN_VALUE_USED(opline)) {
                        if (Z_REFCOUNT_P(retval) == 0) {
@@ -1274,8 +1366,8 @@ ZEND_VM_HELPER_EX(zend_fetch_property_address_read_helper, VAR|UNUSED|CV, CONST|
                                FREE_ZVAL(retval);
                        }
                } else {
-                       AI_SET_PTR(EX_T(opline->result.var).var, retval);
                        PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                }
 
                if (IS_OP2_TMP_FREE()) {
@@ -1286,70 +1378,77 @@ ZEND_VM_HELPER_EX(zend_fetch_property_address_read_helper, VAR|UNUSED|CV, CONST|
        }
 
        FREE_OP1();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(82, ZEND_FETCH_OBJ_R, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
 {
-       ZEND_VM_DISPATCH_TO_HELPER_EX(zend_fetch_property_address_read_helper, type, BP_VAR_R);
+       ZEND_VM_DISPATCH_TO_HELPER(zend_fetch_property_address_read_helper);
 }
 
 ZEND_VM_HANDLER(85, ZEND_FETCH_OBJ_W, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *property = GET_OP2_ZVAL_PTR(BP_VAR_R);
+       zval *property;
        zval **container;
 
+       SAVE_OPLINE();
+       property = GET_OP2_ZVAL_PTR(BP_VAR_R);
+
        if (OP1_TYPE == IS_VAR && (opline->extended_value & ZEND_FETCH_ADD_LOCK)) {
                PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
                EX_T(opline->op1.var).var.ptr = *EX_T(opline->op1.var).var.ptr_ptr;
        }
-
+       
        if (IS_OP2_TMP_FREE()) {
                MAKE_REAL_ZVAL_PTR(property);
        }
        container = GET_OP1_OBJ_ZVAL_PTR_PTR(BP_VAR_W);
-       if (OP1_TYPE == IS_VAR && !container) {
+       if (OP1_TYPE == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
+
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((OP2_TYPE == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
        if (IS_OP2_TMP_FREE()) {
                zval_ptr_dtor(&property);
        } else {
                FREE_OP2();
        }
-       if (OP1_TYPE == IS_VAR && OP1_FREE &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (OP1_TYPE == IS_VAR && OP1_FREE && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        FREE_OP1_VAR_PTR();
 
        /* We are going to assign the result by reference */
        if (opline->extended_value & ZEND_FETCH_MAKE_REF) {
-               Z_DELREF_PP(EX_T(opline->result.var).var.ptr_ptr);
-               SEPARATE_ZVAL_TO_MAKE_IS_REF(EX_T(opline->result.var).var.ptr_ptr);
-               Z_ADDREF_PP(EX_T(opline->result.var).var.ptr_ptr);
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+
+               Z_DELREF_PP(retval_ptr);
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
+               Z_ADDREF_PP(retval_ptr);
        }
        
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(88, ZEND_FETCH_OBJ_RW, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *property = GET_OP2_ZVAL_PTR(BP_VAR_R);
-       zval **container = GET_OP1_OBJ_ZVAL_PTR_PTR(BP_VAR_RW);
+       zval *property;
+       zval **container;
+
+       SAVE_OPLINE();
+       property = GET_OP2_ZVAL_PTR(BP_VAR_R);
+       container = GET_OP1_OBJ_ZVAL_PTR_PTR(BP_VAR_RW);
 
        if (IS_OP2_TMP_FREE()) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       if (OP1_TYPE == IS_VAR && !container) {
+       if (OP1_TYPE == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((OP2_TYPE == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_RW TSRMLS_CC);
@@ -1358,37 +1457,84 @@ ZEND_VM_HANDLER(88, ZEND_FETCH_OBJ_RW, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
        } else {
                FREE_OP2();
        }
-       if (OP1_TYPE == IS_VAR && OP1_FREE &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (OP1_TYPE == IS_VAR && OP1_FREE && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        FREE_OP1_VAR_PTR();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(91, ZEND_FETCH_OBJ_IS, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
 {
-       ZEND_VM_DISPATCH_TO_HELPER_EX(zend_fetch_property_address_read_helper, type, BP_VAR_IS);
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *container;
+       zend_free_op free_op2;
+       zval *offset;
+
+       SAVE_OPLINE();
+       container = GET_OP1_OBJ_ZVAL_PTR(BP_VAR_IS);
+       offset  = GET_OP2_ZVAL_PTR(BP_VAR_R);
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               if (RETURN_VALUE_USED(opline)) {
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+               }
+               FREE_OP2();
+       } else {
+               zval *retval;
+
+               if (IS_OP2_TMP_FREE()) {
+                       MAKE_REAL_ZVAL_PTR(offset);
+               }
+
+               /* here we are sure we are dealing with an object */
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((OP2_TYPE == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+
+               if (!RETURN_VALUE_USED(opline)) {
+                       if (Z_REFCOUNT_P(retval) == 0) {
+                               GC_REMOVE_ZVAL_FROM_BUFFER(retval);
+                               zval_dtor(retval);
+                               FREE_ZVAL(retval);
+                       }
+               } else {
+                       PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
+               }
+
+               if (IS_OP2_TMP_FREE()) {
+                       zval_ptr_dtor(&offset);
+               } else {
+                       FREE_OP2();
+               }
+       }
+
+       FREE_OP1();
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(94, ZEND_FETCH_OBJ_FUNC_ARG, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        if (ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))) {
                /* Behave like FETCH_OBJ_W */
                zend_free_op free_op1, free_op2;
-               zval *property = GET_OP2_ZVAL_PTR(BP_VAR_R);
-               zval **container = GET_OP1_OBJ_ZVAL_PTR_PTR(BP_VAR_W);
+               zval *property;
+               zval **container;
+
+               SAVE_OPLINE();
+               property = GET_OP2_ZVAL_PTR(BP_VAR_R);
+               container = GET_OP1_OBJ_ZVAL_PTR_PTR(BP_VAR_W);
 
                if (IS_OP2_TMP_FREE()) {
                        MAKE_REAL_ZVAL_PTR(property);
                }
-               if (OP1_TYPE == IS_VAR && !container) {
+               if (OP1_TYPE == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
                }
                zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((OP2_TYPE == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
@@ -1397,27 +1543,27 @@ ZEND_VM_HANDLER(94, ZEND_FETCH_OBJ_FUNC_ARG, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
                } else {
                        FREE_OP2();
                }
-               if (OP1_TYPE == IS_VAR && OP1_FREE &&
-                   READY_TO_DESTROY(free_op1.var)) {
-                       AI_USE_PTR(EX_T(opline->result.var).var);
-                       if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                           Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                               SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-                       }
+               if (OP1_TYPE == IS_VAR && OP1_FREE && READY_TO_DESTROY(free_op1.var)) {
+                       EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
                }
                FREE_OP1_VAR_PTR();
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
-               ZEND_VM_DISPATCH_TO_HELPER_EX(zend_fetch_property_address_read_helper, type, BP_VAR_R);
+               ZEND_VM_DISPATCH_TO_HELPER(zend_fetch_property_address_read_helper);
        }
 }
 
 ZEND_VM_HANDLER(97, ZEND_FETCH_OBJ_UNSET, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2, free_res;
-       zval **container = GET_OP1_OBJ_ZVAL_PTR_PTR(BP_VAR_R);
-       zval *property = GET_OP2_ZVAL_PTR(BP_VAR_R);
+       zval **container;
+       zval *property;
+
+       SAVE_OPLINE();
+       container = GET_OP1_OBJ_ZVAL_PTR_PTR(BP_VAR_R);
+       property = GET_OP2_ZVAL_PTR(BP_VAR_R);
 
        if (OP1_TYPE == IS_CV) {
                if (container != &EG(uninitialized_zval_ptr)) {
@@ -1427,7 +1573,7 @@ ZEND_VM_HANDLER(97, ZEND_FETCH_OBJ_UNSET, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
        if (IS_OP2_TMP_FREE()) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       if (OP1_TYPE == IS_VAR && !container) {
+       if (OP1_TYPE == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((OP2_TYPE == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_UNSET TSRMLS_CC);
@@ -1436,13 +1582,8 @@ ZEND_VM_HANDLER(97, ZEND_FETCH_OBJ_UNSET, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
        } else {
                FREE_OP2();
        }
-       if (OP1_TYPE == IS_VAR && OP1_FREE &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (OP1_TYPE == IS_VAR && OP1_FREE && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        FREE_OP1_VAR_PTR();
 
@@ -1452,46 +1593,54 @@ ZEND_VM_HANDLER(97, ZEND_FETCH_OBJ_UNSET, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
        }
        PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
        FREE_OP_VAR_PTR(free_res);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(98, ZEND_FETCH_DIM_TMP_VAR, CONST|TMP, CONST)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *container = GET_OP1_ZVAL_PTR(BP_VAR_R);
+       zval *container;
+
+       SAVE_OPLINE();
+       container = GET_OP1_ZVAL_PTR(BP_VAR_R);
 
-       if (Z_TYPE_P(container) != IS_ARRAY) {
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_ARRAY)) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
        } else {
                zend_free_op free_op2;
-               zval *dim = GET_OP2_ZVAL_PTR(BP_VAR_R);
+               zval *value = *zend_fetch_dimension_address_inner(Z_ARRVAL_P(container), GET_OP2_ZVAL_PTR(BP_VAR_R), OP2_TYPE, BP_VAR_R TSRMLS_CC);
 
-               AI_SET_PTR(EX_T(opline->result.var).var, *zend_fetch_dimension_address_inner(Z_ARRVAL_P(container), dim, OP2_TYPE, BP_VAR_R TSRMLS_CC));
-               SELECTIVE_PZVAL_LOCK(EX_T(opline->result.var).var.ptr, opline);
+               SELECTIVE_PZVAL_LOCK(value, opline);
+               AI_SET_PTR(&EX_T(opline->result.var), value);
                FREE_OP2();
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(136, ZEND_ASSIGN_OBJ, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval **object_ptr = GET_OP1_OBJ_ZVAL_PTR_PTR(BP_VAR_W);
-       zval *property_name = GET_OP2_ZVAL_PTR(BP_VAR_R);
+       zval **object_ptr;
+       zval *property_name;
+
+       SAVE_OPLINE();
+       object_ptr = GET_OP1_OBJ_ZVAL_PTR_PTR(BP_VAR_W);
+       property_name = GET_OP2_ZVAL_PTR(BP_VAR_R);
 
        if (IS_OP2_TMP_FREE()) {
                MAKE_REAL_ZVAL_PTR(property_name);
        }
-       if (OP1_TYPE == IS_VAR && !object_ptr) {
+       if (OP1_TYPE == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, op_data->op1_type, &op_data->op1, EX(Ts), ZEND_ASSIGN_OBJ, ((OP2_TYPE == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), ZEND_ASSIGN_OBJ, ((OP2_TYPE == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
        if (IS_OP2_TMP_FREE()) {
                zval_ptr_dtor(&property_name);
        } else {
@@ -1499,18 +1648,21 @@ ZEND_VM_HANDLER(136, ZEND_ASSIGN_OBJ, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
        }
        FREE_OP1_VAR_PTR();
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(147, ZEND_ASSIGN_DIM, VAR|CV, CONST|TMP|VAR|UNUSED|CV)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **object_ptr = GET_OP1_ZVAL_PTR_PTR(BP_VAR_W);
+       zval **object_ptr;
 
-       if (OP1_TYPE == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = GET_OP1_ZVAL_PTR_PTR(BP_VAR_W);
+
+       if (OP1_TYPE == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
        if (Z_TYPE_PP(object_ptr) == IS_OBJECT) {
@@ -1520,7 +1672,7 @@ ZEND_VM_HANDLER(147, ZEND_ASSIGN_DIM, VAR|CV, CONST|TMP|VAR|UNUSED|CV)
                if (IS_OP2_TMP_FREE()) {
                        MAKE_REAL_ZVAL_PTR(property_name);
                }
-               zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, op_data->op1_type, &op_data->op1, EX(Ts), ZEND_ASSIGN_DIM, ((OP2_TYPE == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+               zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), ZEND_ASSIGN_DIM, ((OP2_TYPE == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
                if (IS_OP2_TMP_FREE()) {
                        zval_ptr_dtor(&property_name);
                } else {
@@ -1532,28 +1684,42 @@ ZEND_VM_HANDLER(147, ZEND_ASSIGN_DIM, VAR|CV, CONST|TMP|VAR|UNUSED|CV)
                zval *dim = GET_OP2_ZVAL_PTR(BP_VAR_R);
                zval **variable_ptr_ptr;
 
-               zend_fetch_dimension_address(&EX_T(op_data->op2.var), object_ptr, dim, OP2_TYPE, BP_VAR_W TSRMLS_CC);
+               zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), object_ptr, dim, OP2_TYPE, BP_VAR_W TSRMLS_CC);
                FREE_OP2();
 
-               value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-               variable_ptr_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-               if (!variable_ptr_ptr) {
-                       if (zend_assign_to_string_offset(&EX_T(op_data->op2.var), value, op_data->op1_type TSRMLS_CC)) {
+               value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+               variable_ptr_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
+               if (UNEXPECTED(variable_ptr_ptr == NULL)) {
+                       if (zend_assign_to_string_offset(&EX_T((opline+1)->op2.var), value, (opline+1)->op1_type TSRMLS_CC)) {
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-                                       ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                                       INIT_PZVAL(EX_T(opline->result.var).var.ptr);
-                                       ZVAL_STRINGL(EX_T(opline->result.var).var.ptr, Z_STRVAL_P(EX_T(op_data->op2.var).str_offset.str)+EX_T(op_data->op2.var).str_offset.offset, 1, 1);
+                                       zval *retval;
+
+                                       ALLOC_ZVAL(retval);
+                                       ZVAL_STRINGL(retval, Z_STRVAL_P(EX_T((opline+1)->op2.var).str_offset.str)+EX_T((opline+1)->op2.var).str_offset.offset, 1, 1);
+                                       INIT_PZVAL(retval);
+                                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                                }
                        } else if (RETURN_VALUE_USED(opline)) {
-                               AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                               PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+                       }
+               } else if (UNEXPECTED(*variable_ptr_ptr == &EG(error_zval))) {
+                       if (IS_TMP_FREE(free_op_data1)) {
+                               zval_dtor(value);
+                       }
+                       if (RETURN_VALUE_USED(opline)) {
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                        }
                } else {
-                       value = zend_assign_to_variable(variable_ptr_ptr, value, IS_TMP_FREE(free_op_data1) TSRMLS_CC);
+                       if (IS_TMP_FREE(free_op_data1)) {
+                               value = zend_assign_tmp_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+                       } else {
+                               value = zend_assign_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+                       }
                        if (RETURN_VALUE_USED(opline)) {
-                               AI_SET_PTR(EX_T(opline->result.var).var, value);
                                PZVAL_LOCK(value);
+                               AI_SET_PTR(&EX_T(opline->result.var), value);
                        }
                }
                FREE_OP_VAR_PTR(free_op_data2);
@@ -1561,34 +1727,53 @@ ZEND_VM_HANDLER(147, ZEND_ASSIGN_DIM, VAR|CV, CONST|TMP|VAR|UNUSED|CV)
        }
        FREE_OP1_VAR_PTR();
        /* assign_dim has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(38, ZEND_ASSIGN, VAR|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *value = GET_OP2_ZVAL_PTR(BP_VAR_R);
-       zval **variable_ptr_ptr = GET_OP1_ZVAL_PTR_PTR(BP_VAR_W);
+       zval *value;
+       zval **variable_ptr_ptr;
 
-       if (OP1_TYPE == IS_VAR && !variable_ptr_ptr) {
+       SAVE_OPLINE();
+       value = GET_OP2_ZVAL_PTR(BP_VAR_R);
+       variable_ptr_ptr = GET_OP1_ZVAL_PTR_PTR(BP_VAR_W);
+
+       if (OP1_TYPE == IS_VAR && UNEXPECTED(variable_ptr_ptr == NULL)) {
                if (zend_assign_to_string_offset(&EX_T(opline->op1.var), value, OP2_TYPE TSRMLS_CC)) {
                        if (RETURN_VALUE_USED(opline)) {
-                               EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-                               ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                               INIT_PZVAL(EX_T(opline->result.var).var.ptr);
-                               ZVAL_STRINGL(EX_T(opline->result.var).var.ptr, Z_STRVAL_P(EX_T(opline->op1.var).str_offset.str)+EX_T(opline->op1.var).str_offset.offset, 1, 1);
+                               zval *retval;
+
+                               ALLOC_ZVAL(retval);
+                               ZVAL_STRINGL(retval, Z_STRVAL_P(EX_T(opline->op1.var).str_offset.str)+EX_T(opline->op1.var).str_offset.offset, 1, 1);
+                               INIT_PZVAL(retval);
+                               AI_SET_PTR(&EX_T(opline->result.var), retval);
                        }
                } else if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+               }
+       } else if (OP1_TYPE == IS_VAR && UNEXPECTED(*variable_ptr_ptr == &EG(error_zval))) {
+               if (IS_OP2_TMP_FREE()) {
+                       zval_dtor(value);
+               }
+               if (RETURN_VALUE_USED(opline)) {
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
        } else {
-               value = zend_assign_to_variable(variable_ptr_ptr, value, IS_OP2_TMP_FREE() TSRMLS_CC);
+               if (IS_OP2_TMP_FREE()) {
+                       value = zend_assign_tmp_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+               } else {
+                       value = zend_assign_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+               }
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, value);
                        PZVAL_LOCK(value);
+                       AI_SET_PTR(&EX_T(opline->result.var), value);
                }
        }
 
@@ -1597,15 +1782,19 @@ ZEND_VM_HANDLER(38, ZEND_ASSIGN, VAR|CV, CONST|TMP|VAR|CV)
        /* zend_assign_to_variable() always takes care of op2, never free it! */
        FREE_OP2_IF_VAR();
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(39, ZEND_ASSIGN_REF, VAR|CV, VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval **variable_ptr_ptr;
-       zval **value_ptr_ptr = GET_OP2_ZVAL_PTR_PTR(BP_VAR_W);
+       zval **value_ptr_ptr;
+
+       SAVE_OPLINE();
+       value_ptr_ptr = GET_OP2_ZVAL_PTR_PTR(BP_VAR_W);
 
        if (OP2_TYPE == IS_VAR &&
            value_ptr_ptr &&
@@ -1618,19 +1807,19 @@ ZEND_VM_HANDLER(39, ZEND_ASSIGN_REF, VAR|CV, VAR|CV)
                zend_error(E_STRICT, "Only variables should be assigned by reference");
                if (UNEXPECTED(EG(exception) != NULL)) {
                        FREE_OP2_VAR_PTR();
-                       ZEND_VM_NEXT_OPCODE();
+                       HANDLE_EXCEPTION();
                }
                ZEND_VM_DISPATCH_TO_HANDLER(ZEND_ASSIGN);
        } else if (OP2_TYPE == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
                PZVAL_LOCK(*value_ptr_ptr);
        }
-       if (OP1_TYPE == IS_VAR && EX_T(opline->op1.var).var.ptr_ptr == &EX_T(opline->op1.var).var.ptr) {
+       if (OP1_TYPE == IS_VAR && UNEXPECTED(EX_T(opline->op1.var).var.ptr_ptr == &EX_T(opline->op1.var).var.ptr)) {
                zend_error_noreturn(E_ERROR, "Cannot assign by reference to overloaded object");
        }
 
        variable_ptr_ptr = GET_OP1_ZVAL_PTR_PTR(BP_VAR_W);
-       if ((OP2_TYPE == IS_VAR && !value_ptr_ptr) ||
-           (OP1_TYPE == IS_VAR && !variable_ptr_ptr)) {
+       if ((OP2_TYPE == IS_VAR && UNEXPECTED(value_ptr_ptr == NULL)) ||
+           (OP1_TYPE == IS_VAR && UNEXPECTED(variable_ptr_ptr == NULL))) {
                zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
        }
        zend_assign_to_variable_reference(variable_ptr_ptr, value_ptr_ptr TSRMLS_CC);
@@ -1640,39 +1829,45 @@ ZEND_VM_HANDLER(39, ZEND_ASSIGN_REF, VAR|CV, VAR|CV)
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *variable_ptr_ptr);
                PZVAL_LOCK(*variable_ptr_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *variable_ptr_ptr);
        }
 
        FREE_OP1_VAR_PTR();
        FREE_OP2_VAR_PTR();
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(42, ZEND_JMP, ANY, ANY)
 {
+       USE_OPLINE
+
 #if DEBUG_ZEND>=2
-       printf("Jumping to %d\n", EX(opline)->op1.opline_num);
+       printf("Jumping to %d\n", opline->op1.opline_num);
 #endif
-       ZEND_VM_SET_OPCODE(EX(opline)->op1.jmp_addr);
+       ZEND_VM_SET_OPCODE(opline->op1.jmp_addr);
        ZEND_VM_CONTINUE(); /* CHECK_ME */
 }
 
 ZEND_VM_HANDLER(43, ZEND_JMPZ, CONST|TMP|VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *val = GET_OP1_ZVAL_PTR(BP_VAR_R);
+       zval *val;
        int ret;
 
-       if (OP1_TYPE == IS_TMP_VAR && Z_TYPE_P(val) == IS_BOOL) {
+       SAVE_OPLINE();
+       val = GET_OP1_ZVAL_PTR(BP_VAR_R);
+
+       if (OP1_TYPE == IS_TMP_VAR && EXPECTED(Z_TYPE_P(val) == IS_BOOL)) {
                ret = Z_LVAL_P(val);
        } else {
                ret = i_zend_is_true(val);
                FREE_OP1();
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       ZEND_VM_CONTINUE();
+                       HANDLE_EXCEPTION();
                }
        }
        if (!ret) {
@@ -1688,18 +1883,21 @@ ZEND_VM_HANDLER(43, ZEND_JMPZ, CONST|TMP|VAR|CV, ANY)
 
 ZEND_VM_HANDLER(44, ZEND_JMPNZ, CONST|TMP|VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *val = GET_OP1_ZVAL_PTR(BP_VAR_R);
+       zval *val;
        int ret;
 
-       if (OP1_TYPE == IS_TMP_VAR && Z_TYPE_P(val) == IS_BOOL) {
+       SAVE_OPLINE();
+       val = GET_OP1_ZVAL_PTR(BP_VAR_R);
+
+       if (OP1_TYPE == IS_TMP_VAR && EXPECTED(Z_TYPE_P(val) == IS_BOOL)) {
                ret = Z_LVAL_P(val);
        } else {
                ret = i_zend_is_true(val);
                FREE_OP1();
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       ZEND_VM_CONTINUE();
+                       HANDLE_EXCEPTION();
                }
        }
        if (ret) {
@@ -1715,18 +1913,21 @@ ZEND_VM_HANDLER(44, ZEND_JMPNZ, CONST|TMP|VAR|CV, ANY)
 
 ZEND_VM_HANDLER(45, ZEND_JMPZNZ, CONST|TMP|VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *val = GET_OP1_ZVAL_PTR(BP_VAR_R);
+       zval *val;
        int retval;
 
-       if (OP1_TYPE == IS_TMP_VAR && Z_TYPE_P(val) == IS_BOOL) {
+       SAVE_OPLINE();
+       val = GET_OP1_ZVAL_PTR(BP_VAR_R);
+
+       if (OP1_TYPE == IS_TMP_VAR && EXPECTED(Z_TYPE_P(val) == IS_BOOL)) {
                retval = Z_LVAL_P(val);
        } else {
                retval = i_zend_is_true(val);
                FREE_OP1();
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       ZEND_VM_CONTINUE();
+                       HANDLE_EXCEPTION();
                }
        }
        if (EXPECTED(retval != 0)) {
@@ -1746,18 +1947,21 @@ ZEND_VM_HANDLER(45, ZEND_JMPZNZ, CONST|TMP|VAR|CV, ANY)
 
 ZEND_VM_HANDLER(46, ZEND_JMPZ_EX, CONST|TMP|VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *val = GET_OP1_ZVAL_PTR(BP_VAR_R);
+       zval *val;
        int retval;
 
-       if (OP1_TYPE == IS_TMP_VAR && Z_TYPE_P(val) == IS_BOOL) {
+       SAVE_OPLINE();
+       val = GET_OP1_ZVAL_PTR(BP_VAR_R);
+
+       if (OP1_TYPE == IS_TMP_VAR && EXPECTED(Z_TYPE_P(val) == IS_BOOL)) {
                retval = Z_LVAL_P(val);
        } else {
                retval = i_zend_is_true(val);
                FREE_OP1();
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       ZEND_VM_CONTINUE();
+                       HANDLE_EXCEPTION();
                }
        }
        Z_LVAL(EX_T(opline->result.var).tmp_var) = retval;
@@ -1774,18 +1978,21 @@ ZEND_VM_HANDLER(46, ZEND_JMPZ_EX, CONST|TMP|VAR|CV, ANY)
 
 ZEND_VM_HANDLER(47, ZEND_JMPNZ_EX, CONST|TMP|VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *val = GET_OP1_ZVAL_PTR(BP_VAR_R);
+       zval *val;
        int retval;
 
-       if (OP1_TYPE == IS_TMP_VAR && Z_TYPE_P(val) == IS_BOOL) {
+       SAVE_OPLINE();
+       val = GET_OP1_ZVAL_PTR(BP_VAR_R);
+
+       if (OP1_TYPE == IS_TMP_VAR && EXPECTED(Z_TYPE_P(val) == IS_BOOL)) {
                retval = Z_LVAL_P(val);
        } else {
                retval = i_zend_is_true(val);
                FREE_OP1();
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       ZEND_VM_CONTINUE();
+                       HANDLE_EXCEPTION();
                }
        }
        Z_LVAL(EX_T(opline->result.var).tmp_var) = retval;
@@ -1802,28 +2009,37 @@ ZEND_VM_HANDLER(47, ZEND_JMPNZ_EX, CONST|TMP|VAR|CV, ANY)
 
 ZEND_VM_HANDLER(70, ZEND_FREE, TMP, ANY)
 {
-       zendi_zval_dtor(EX_T(EX(opline)->op1.var).tmp_var);
+       USE_OPLINE
+
+       SAVE_OPLINE();
+       zendi_zval_dtor(EX_T(opline->op1.var).tmp_var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(53, ZEND_INIT_STRING, ANY, ANY)
 {
-       zval *tmp = &EX_T(EX(opline)->result.var).tmp_var;
+       USE_OPLINE
+       zval *tmp = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        tmp->value.str.val = emalloc(1);
        tmp->value.str.val[0] = 0;
        tmp->value.str.len = 0;
        Z_SET_REFCOUNT_P(tmp, 1);
        tmp->type = IS_STRING;
        Z_UNSET_ISREF_P(tmp);
+       /*CHECK_EXCEPTION();*/
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(54, ZEND_ADD_CHAR, TMP|UNUSED, CONST)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *str = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
+
        if (OP1_TYPE == IS_UNUSED) {
                /* Initialize for erealloc in add_char_to_string */
                Z_STRVAL_P(str) = NULL;
@@ -1836,14 +2052,17 @@ ZEND_VM_HANDLER(54, ZEND_ADD_CHAR, TMP|UNUSED, CONST)
        add_char_to_string(str, str, opline->op2.zv);
 
        /* FREE_OP is missing intentionally here - we're always working on the same temporary variable */
+       /*CHECK_EXCEPTION();*/
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(55, ZEND_ADD_STRING, TMP|UNUSED, CONST)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *str = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
+
        if (OP1_TYPE == IS_UNUSED) {
                /* Initialize for erealloc in add_string_to_string */
                Z_STRVAL_P(str) = NULL;
@@ -1856,18 +2075,22 @@ ZEND_VM_HANDLER(55, ZEND_ADD_STRING, TMP|UNUSED, CONST)
        add_string_to_string(str, str, opline->op2.zv);
 
        /* FREE_OP is missing intentionally here - we're always working on the same temporary variable */
+       /*CHECK_EXCEPTION();*/
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(56, ZEND_ADD_VAR, TMP|UNUSED, TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval *str = &EX_T(opline->result.var).tmp_var;
-       zval *var = GET_OP2_ZVAL_PTR(BP_VAR_R);
+       zval *var;
        zval var_copy;
        int use_copy = 0;
 
+       SAVE_OPLINE();
+       var = GET_OP2_ZVAL_PTR(BP_VAR_R);
+       
        if (OP1_TYPE == IS_UNUSED) {
                /* Initialize for erealloc in add_string_to_string */
                Z_STRVAL_P(str) = NULL;
@@ -1897,16 +2120,19 @@ ZEND_VM_HANDLER(56, ZEND_ADD_VAR, TMP|UNUSED, TMP|VAR|CV)
         */
        FREE_OP2();
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(109, ZEND_FETCH_CLASS, ANY, CONST|TMP|VAR|UNUSED|CV)
 {
-       zend_op *opline = EX(opline);
-
+       USE_OPLINE
 
+       SAVE_OPLINE();
+       EG(exception) = NULL;
        if (OP2_TYPE == IS_UNUSED) {
                EX_T(opline->result.var).class_entry = zend_fetch_class(NULL, 0, opline->extended_value TSRMLS_CC);
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
                zend_free_op free_op2;
@@ -1923,23 +2149,26 @@ ZEND_VM_HANDLER(109, ZEND_FETCH_CLASS, ANY, CONST|TMP|VAR|UNUSED|CV)
                }
 
                FREE_OP2();
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 }
 
 ZEND_VM_HANDLER(112, ZEND_INIT_METHOD_CALL, TMP|VAR|UNUSED|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        char *function_name_strval;
        int function_name_strlen;
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
        function_name = GET_OP2_ZVAL_PTR(BP_VAR_R);
 
-       if (Z_TYPE_P(function_name)!=IS_STRING) {
+       if (OP2_TYPE != IS_CONST &&
+           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                zend_error_noreturn(E_ERROR, "Method name must be a string");
        }
 
@@ -1948,14 +2177,15 @@ ZEND_VM_HANDLER(112, ZEND_INIT_METHOD_CALL, TMP|VAR|UNUSED|CV, CONST|TMP|VAR|CV)
 
        EX(object) = GET_OP1_OBJ_ZVAL_PTR(BP_VAR_R);
 
-       if (EX(object) && Z_TYPE_P(EX(object)) == IS_OBJECT) {
-               if (Z_OBJ_HT_P(EX(object))->get_method == NULL) {
+       if (EXPECTED(EX(object) != NULL) &&
+           EXPECTED(Z_TYPE_P(EX(object)) == IS_OBJECT)) {
+               if (UNEXPECTED(Z_OBJ_HT_P(EX(object))->get_method == NULL)) {
                        zend_error_noreturn(E_ERROR, "Object does not support method calls");
                }
 
                /* First, locate the function. */
                EX(fbc) = Z_OBJ_HT_P(EX(object))->get_method(&EX(object), function_name_strval, function_name_strlen, ((OP2_TYPE == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
-               if (!EX(fbc)) {
+               if (UNEXPECTED(EX(fbc) == NULL)) {
                        zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", Z_OBJ_CLASS_NAME_P(EX(object)), function_name_strval);
                }
                
@@ -1981,21 +2211,23 @@ ZEND_VM_HANDLER(112, ZEND_INIT_METHOD_CALL, TMP|VAR|UNUSED|CV, CONST|TMP|VAR|CV)
        FREE_OP2();
        FREE_OP1_IF_VAR();
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(113, ZEND_INIT_STATIC_METHOD_CALL, CONST|VAR, CONST|TMP|VAR|UNUSED|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        zend_class_entry *ce;
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
        if (OP1_TYPE == IS_CONST) {
                /* no function found. try a static method in class */
                ce = zend_fetch_class_by_name(Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), opline->op1.literal + 1, opline->extended_value TSRMLS_CC);
-               if (!ce) {
+               if (UNEXPECTED(ce == NULL)) {
                        zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
                }
                EX(called_scope) = ce;
@@ -2019,7 +2251,7 @@ ZEND_VM_HANDLER(113, ZEND_INIT_STATIC_METHOD_CALL, CONST|VAR, CONST|TMP|VAR|UNUS
                } else {
                        function_name = GET_OP2_ZVAL_PTR(BP_VAR_R);
 
-                       if (Z_TYPE_P(function_name) != IS_STRING) {
+                       if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                                zend_error_noreturn(E_ERROR, "Function name must be a string");
                        } else {
                                function_name_strval = Z_STRVAL_P(function_name);
@@ -2033,7 +2265,7 @@ ZEND_VM_HANDLER(113, ZEND_INIT_STATIC_METHOD_CALL, CONST|VAR, CONST|TMP|VAR|UNUS
                        } else {
                                EX(fbc) = zend_std_get_static_method(ce, function_name_strval, function_name_strlen, ((OP2_TYPE == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
                        }
-                       if (!EX(fbc)) {
+                       if (UNEXPECTED(EX(fbc) == NULL)) {
                                zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name, function_name_strval);
                        }
                }
@@ -2042,11 +2274,11 @@ ZEND_VM_HANDLER(113, ZEND_INIT_STATIC_METHOD_CALL, CONST|VAR, CONST|TMP|VAR|UNUS
                        FREE_OP2();
                }
        } else {
-               if(!ce->constructor) {
+               if (UNEXPECTED(ce->constructor == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot call constructor");
                }
                if (EG(This) && Z_OBJCE_P(EG(This)) != ce->constructor->common.scope && (ce->constructor->common.fn_flags & ZEND_ACC_PRIVATE)) {
-                       zend_error(E_COMPILE_ERROR, "Cannot call private %s::__construct()", ce->name);
+                       zend_error_noreturn(E_ERROR, "Cannot call private %s::__construct()", ce->name);
                }
                EX(fbc) = ce->constructor;
        }
@@ -2078,77 +2310,83 @@ ZEND_VM_HANDLER(113, ZEND_INIT_STATIC_METHOD_CALL, CONST|VAR, CONST|TMP|VAR|UNUS
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(59, ZEND_INIT_FCALL_BY_NAME, ANY, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
-       char *function_name_strval, *lcname;
-       int function_name_strlen;
-       zend_free_op free_op2;
-
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
        if (OP2_TYPE == IS_CONST) {
-               if (zend_hash_quick_find(EG(function_table), Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv)+1, Z_HASH_P(opline->op1.zv), (void **) &EX(fbc)) == FAILURE) {
+               function_name = opline->op1.zv;
+               if (UNEXPECTED(zend_hash_quick_find(EG(function_table), Z_STRVAL_P(function_name), Z_STRLEN_P(function_name)+1, Z_HASH_P(function_name), (void **) &EX(fbc)) == FAILURE)) {
+                       SAVE_OPLINE();
                        zend_error_noreturn(E_ERROR, "Call to undefined function %s()", Z_STRVAL_P(opline->op2.zv));
                }
+               EX(object) = NULL;
+               /*CHECK_EXCEPTION();*/
+               ZEND_VM_NEXT_OPCODE();
        } else {
+               char *function_name_strval, *lcname;
+               int function_name_strlen;
+               zend_free_op free_op2;
+
+               SAVE_OPLINE();
                function_name = GET_OP2_ZVAL_PTR(BP_VAR_R);
 
-               if (OP2_TYPE != IS_CONST &&
-                   Z_TYPE_P(function_name) == IS_OBJECT &&
+               if (EXPECTED(Z_TYPE_P(function_name) == IS_STRING)) {
+                       function_name_strval = Z_STRVAL_P(function_name);
+                       function_name_strlen = Z_STRLEN_P(function_name);
+                       if (function_name_strval[0] == '\\') {
+                           function_name_strlen -= 1;
+                               lcname = zend_str_tolower_dup(function_name_strval + 1, function_name_strlen);
+                       } else {
+                               lcname = zend_str_tolower_dup(function_name_strval, function_name_strlen);
+                       }
+                       if (UNEXPECTED(zend_hash_find(EG(function_table), lcname, function_name_strlen+1, (void **) &EX(fbc)) == FAILURE)) {
+                               zend_error_noreturn(E_ERROR, "Call to undefined function %s()", function_name_strval);
+                       }
+                       efree(lcname);
+                       FREE_OP2();
+                       EX(object) = NULL;
+                       CHECK_EXCEPTION();
+                       ZEND_VM_NEXT_OPCODE();
+               } else if (OP2_TYPE != IS_CONST &&
+                   EXPECTED(Z_TYPE_P(function_name) == IS_OBJECT) &&
                        Z_OBJ_HANDLER_P(function_name, get_closure) &&
                        Z_OBJ_HANDLER_P(function_name, get_closure)(function_name, &EX(called_scope), &EX(fbc), &EX(object) TSRMLS_CC) == SUCCESS) {
                        if (EX(object)) {
                                Z_ADDREF_P(EX(object));
                        }
                        FREE_OP2();
+                       CHECK_EXCEPTION();
                        ZEND_VM_NEXT_OPCODE();
-               }
-
-               if (Z_TYPE_P(function_name) != IS_STRING) {
-                       zend_error_noreturn(E_ERROR, "Function name must be a string");
-               }
-               function_name_strval = Z_STRVAL_P(function_name);
-               function_name_strlen = Z_STRLEN_P(function_name);
-               if (function_name_strval[0] == '\\') {
-
-                   function_name_strlen -= 1;
-                       lcname = zend_str_tolower_dup(function_name_strval + 1, function_name_strlen);
                } else {
-                       lcname = zend_str_tolower_dup(function_name_strval, function_name_strlen);
-               }
-               if (zend_hash_find(EG(function_table), lcname, function_name_strlen+1, (void **) &EX(fbc)) == FAILURE) {
-                       zend_error_noreturn(E_ERROR, "Call to undefined function %s()", function_name_strval);
+                       zend_error_noreturn(E_ERROR, "Function name must be a string");
                }
-               efree(lcname);
-               FREE_OP2();
        }
-
-       EX(object) = NULL;
-       ZEND_VM_NEXT_OPCODE();
 }
 
 
 ZEND_VM_HANDLER(69, ZEND_INIT_NS_FCALL_BY_NAME, ANY, CONST)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline + 1;
+       USE_OPLINE
 
-       ZEND_VM_INC_OPCODE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
        if (zend_hash_quick_find(EG(function_table), Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv)+1, Z_HASH_P(opline->op1.zv), (void **) &EX(fbc))==FAILURE) {
-               char *short_name = Z_STRVAL_P(opline->op1.zv)+op_data->op1.num;
-               if (zend_hash_quick_find(EG(function_table), short_name, Z_STRLEN_P(opline->op1.zv)-op_data->op1.num+1, op_data->extended_value, (void **) &EX(fbc))==FAILURE) {
+               char *short_name = Z_STRVAL_P(opline->op1.zv) + (opline+1)->op1.num;
+               if (UNEXPECTED(zend_hash_quick_find(EG(function_table), short_name, Z_STRLEN_P(opline->op1.zv) - (opline+1)->op1.num+1, (opline+1)->extended_value, (void **) &EX(fbc))==FAILURE)) {
+                       SAVE_OPLINE();
                        zend_error_noreturn(E_ERROR, "Call to undefined function %s()", Z_STRVAL_P(opline->op2.zv));
                }
        }
 
        EX(object) = NULL;
+       ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -2160,8 +2398,8 @@ ZEND_VM_HELPER(zend_leave_helper, ANY, ANY)
        EG(current_execute_data) = EX(prev_execute_data);
        EG(opline_ptr) = NULL;
        if (!EG(active_symbol_table)) {
-               zval ***cv = EX(CVs);
-               zval ***end = cv + EX(op_array)->last_var;
+               zval ***cv = EX_CVs();
+               zval ***end = cv + op_array->last_var;
                while (cv != end) {
                        if (*cv) {
                                zval_ptr_dtor(*cv);
@@ -2176,32 +2414,38 @@ ZEND_VM_HELPER(zend_leave_helper, ANY, ANY)
 
        if (nested) {
                execute_data = EG(current_execute_data);
+       }
+       if (nested) {
+               USE_OPLINE
 
-               if (EX(call_opline)->opcode == ZEND_INCLUDE_OR_EVAL) {
+               LOAD_REGS();
+               LOAD_OPLINE();
+               if (UNEXPECTED(opline->opcode == ZEND_INCLUDE_OR_EVAL)) {
 
                        EX(function_state).function = (zend_function *) EX(op_array);
                        EX(function_state).arguments = NULL;
                        EX(object) = EX(current_object);
 
-                       if (RETURN_VALUE_USED(EX(call_opline))) {
-                               if (!EX_T(EX(call_opline)->result.var).var.ptr) { /* there was no return statement */
-                                       ALLOC_ZVAL(EX_T(EX(call_opline)->result.var).var.ptr);
-                                       INIT_PZVAL(EX_T(EX(call_opline)->result.var).var.ptr);
-                                       Z_LVAL_P(EX_T(EX(call_opline)->result.var).var.ptr) = 1;
-                                       Z_TYPE_P(EX_T(EX(call_opline)->result.var).var.ptr) = IS_BOOL;
-                               }
-                       }
-
                        EG(opline_ptr) = &EX(opline);
                        EG(active_op_array) = EX(op_array);
                        EG(return_value_ptr_ptr) = EX(original_return_value);
                        destroy_op_array(op_array TSRMLS_CC);
                        efree(op_array);
-                       if (EG(exception)) {
+                       if (UNEXPECTED(EG(exception) != NULL)) {
                                zend_throw_exception_internal(NULL TSRMLS_CC);
+                               HANDLE_EXCEPTION_LEAVE();
+                       } else if (RETURN_VALUE_USED(opline)) {
+                               if (!EX_T(opline->result.var).var.ptr) { /* there was no return statement */
+                                       zval *retval;
+
+                                       ALLOC_ZVAL(retval);
+                                       ZVAL_BOOL(retval, 1);
+                                       INIT_PZVAL(retval);
+                                       EX_T(opline->result.var).var.ptr = retval;
+                               }
                        }
 
-                       EX(opline)++;
+                       ZEND_VM_INC_OPCODE();
                        ZEND_VM_LEAVE();
                } else {
 
@@ -2225,7 +2469,7 @@ ZEND_VM_HELPER(zend_leave_helper, ANY, ANY)
                        EX(function_state).arguments = NULL;
 
                        if (EG(This)) {
-                               if (EG(exception) && IS_CTOR_CALL(EX(called_scope))) {
+                               if (UNEXPECTED(EG(exception) != NULL) && IS_CTOR_CALL(EX(called_scope))) {
                                        if (IS_CTOR_USED(EX(called_scope))) {
                                                Z_DELREF_P(EG(This));
                                        }
@@ -2244,14 +2488,15 @@ ZEND_VM_HELPER(zend_leave_helper, ANY, ANY)
 
                        zend_vm_stack_clear_multiple(TSRMLS_C);
 
-                       if (EG(exception)) {
+                       if (UNEXPECTED(EG(exception) != NULL)) {
                                zend_throw_exception_internal(NULL TSRMLS_CC);
-                               if (RETURN_VALUE_USED(EX(call_opline)) && EX_T(EX(call_opline)->result.var).var.ptr) {
-                                       zval_ptr_dtor(&EX_T(EX(call_opline)->result.var).var.ptr);
+                               if (RETURN_VALUE_USED(opline) && EX_T(opline->result.var).var.ptr) {
+                                       zval_ptr_dtor(&EX_T(opline->result.var).var.ptr);
                                }
+                               HANDLE_EXCEPTION_LEAVE();
                        }
 
-                       EX(opline)++;
+                       ZEND_VM_INC_OPCODE();
                        ZEND_VM_LEAVE();
                }
        }
@@ -2260,89 +2505,99 @@ ZEND_VM_HELPER(zend_leave_helper, ANY, ANY)
 
 ZEND_VM_HELPER(zend_do_fcall_common_helper, ANY, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_bool should_change_scope = 0;
+       zend_function *fbc = EX(function_state).function;
 
-       if (EX(function_state).function->common.fn_flags & (ZEND_ACC_ABSTRACT|ZEND_ACC_DEPRECATED)) {
-               if (EX(function_state).function->common.fn_flags & ZEND_ACC_ABSTRACT) {
-                       zend_error_noreturn(E_ERROR, "Cannot call abstract method %s::%s()", EX(function_state).function->common.scope->name, EX(function_state).function->common.function_name);
+       SAVE_OPLINE();
+       if (UNEXPECTED((fbc->common.fn_flags & (ZEND_ACC_ABSTRACT|ZEND_ACC_DEPRECATED)) != 0)) {
+               if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_ABSTRACT) != 0)) {
+                       zend_error_noreturn(E_ERROR, "Cannot call abstract method %s::%s()", fbc->common.scope->name, fbc->common.function_name);
+                       CHECK_EXCEPTION();
                        ZEND_VM_NEXT_OPCODE(); /* Never reached */
                }
-               if (EX(function_state).function->common.fn_flags & ZEND_ACC_DEPRECATED) {
+               if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_DEPRECATED) != 0)) {
                        zend_error(E_DEPRECATED, "Function %s%s%s() is deprecated",
-                               EX(function_state).function->common.scope ? EX(function_state).function->common.scope->name : "",
-                               EX(function_state).function->common.scope ? "::" : "",
-                               EX(function_state).function->common.function_name);
+                               fbc->common.scope ? fbc->common.scope->name : "",
+                               fbc->common.scope ? "::" : "",
+                               fbc->common.function_name);
                }
        }
-       if (EX(function_state).function->common.scope &&
-               !(EX(function_state).function->common.fn_flags & ZEND_ACC_STATIC) &&
+       if (fbc->common.scope &&
+               !(fbc->common.fn_flags & ZEND_ACC_STATIC) &&
                !EX(object)) {
 
-               if (EX(function_state).function->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
+               if (fbc->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
                        /* FIXME: output identifiers properly */
-                       zend_error(E_STRICT, "Non-static method %s::%s() should not be called statically", EX(function_state).function->common.scope->name, EX(function_state).function->common.function_name);
+                       zend_error(E_STRICT, "Non-static method %s::%s() should not be called statically", fbc->common.scope->name, fbc->common.function_name);
                } else {
                        /* FIXME: output identifiers properly */
                        /* An internal function assumes $this is present and won't check that. So PHP would crash by allowing the call. */
-                       zend_error_noreturn(E_ERROR, "Non-static method %s::%s() cannot be called statically", EX(function_state).function->common.scope->name, EX(function_state).function->common.function_name);
+                       zend_error_noreturn(E_ERROR, "Non-static method %s::%s() cannot be called statically", fbc->common.scope->name, fbc->common.function_name);
                }
        }
 
-       if (EX(function_state).function->type == ZEND_USER_FUNCTION ||
-           EX(function_state).function->common.scope) {
+       if (fbc->type == ZEND_USER_FUNCTION || fbc->common.scope) {
                should_change_scope = 1;
                EX(current_this) = EG(This);
                EX(current_scope) = EG(scope);
                EX(current_called_scope) = EG(called_scope);
                EG(This) = EX(object);
-               EG(scope) = (EX(function_state).function->type == ZEND_USER_FUNCTION || !EX(object)) ? EX(function_state).function->common.scope : NULL;
+               EG(scope) = (fbc->type == ZEND_USER_FUNCTION || !EX(object)) ? fbc->common.scope : NULL;
                EG(called_scope) = EX(called_scope);
        }
 
        zend_arg_types_stack_3_pop(&EG(arg_types_stack), &EX(called_scope), &EX(current_object), &EX(fbc));
        EX(function_state).arguments = zend_vm_stack_push_args(opline->extended_value TSRMLS_CC);
+       LOAD_OPLINE();
 
-       if (EX(function_state).function->type == ZEND_INTERNAL_FUNCTION) {
-               ALLOC_INIT_ZVAL(EX_T(opline->result.var).var.ptr);
-               EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-               EX_T(opline->result.var).var.fcall_returned_reference = EX(function_state).function->common.return_reference;
+       if (fbc->type == ZEND_INTERNAL_FUNCTION) {
+               temp_variable *ret = &EX_T(opline->result.var);
 
-               if (EX(function_state).function->common.arg_info) {
+               MAKE_STD_ZVAL(ret->var.ptr);
+               ZVAL_NULL(ret->var.ptr);
+               ret->var.ptr_ptr = &ret->var.ptr;
+               ret->var.fcall_returned_reference = fbc->common.return_reference;
+
+               if (fbc->common.arg_info) {
                        zend_uint i=0;
                        zval **p = (zval**)EX(function_state).arguments;
                        ulong arg_count = opline->extended_value;
 
                        while (arg_count>0) {
-                               zend_verify_arg_type(EX(function_state).function, ++i, *(p-arg_count), 0 TSRMLS_CC);
+                               zend_verify_arg_type(fbc, ++i, *(p-arg_count), 0 TSRMLS_CC);
                                arg_count--;
                        }
                }
+
                if (!zend_execute_internal) {
                        /* saves one function call if zend_execute_internal is not used */
-                       ((zend_internal_function *) EX(function_state).function)->handler(opline->extended_value, EX_T(opline->result.var).var.ptr, EX(function_state).function->common.return_reference?&EX_T(opline->result.var).var.ptr:NULL, EX(object), RETURN_VALUE_USED(opline) TSRMLS_CC);
+                       fbc->internal_function.handler(opline->extended_value, ret->var.ptr, fbc->common.return_reference ? &ret->var.ptr : NULL, EX(object), RETURN_VALUE_USED(opline) TSRMLS_CC);
                } else {
                        zend_execute_internal(EXECUTE_DATA, RETURN_VALUE_USED(opline) TSRMLS_CC);
                }
 
                if (!RETURN_VALUE_USED(opline)) {
-                       zval_ptr_dtor(&EX_T(opline->result.var).var.ptr);
+                       zval_ptr_dtor(&ret->var.ptr);
                }
-       } else if (EX(function_state).function->type == ZEND_USER_FUNCTION) {
+       } else if (fbc->type == ZEND_USER_FUNCTION) {
                EX(original_return_value) = EG(return_value_ptr_ptr);
                EG(active_symbol_table) = NULL;
-               EG(active_op_array) = &EX(function_state).function->op_array;
+               EG(active_op_array) = &fbc->op_array;
                EG(return_value_ptr_ptr) = NULL;
-               if (RETURN_VALUE_USED(opline)) {                        
-                       EG(return_value_ptr_ptr) = &EX_T(opline->result.var).var.ptr;
-                       EX_T(opline->result.var).var.ptr = NULL;
-                       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-                       EX_T(opline->result.var).var.fcall_returned_reference = EX(function_state).function->common.return_reference;
+               if (RETURN_VALUE_USED(opline)) {
+                       temp_variable *ret = &EX_T(opline->result.var);
+
+                       ret->var.ptr = NULL;
+                       EG(return_value_ptr_ptr) = &ret->var.ptr;
+                       ret->var.ptr_ptr = &ret->var.ptr;
+                       ret->var.fcall_returned_reference = fbc->common.return_reference;
                }
 
-               if (zend_execute == execute && !EG(exception)) {
-                       EX(call_opline) = opline;
-                       ZEND_VM_ENTER();
+               if (EXPECTED(zend_execute == execute)) {
+                       if (EXPECTED(EG(exception) == NULL)) {
+                               ZEND_VM_ENTER();
+                       }
                } else {
                        zend_execute(EG(active_op_array) TSRMLS_CC);
                }
@@ -2363,19 +2618,20 @@ ZEND_VM_HELPER(zend_do_fcall_common_helper, ANY, ANY)
                }
                EG(active_symbol_table) = EX(symbol_table);
        } else { /* ZEND_OVERLOADED_FUNCTION */
-               ALLOC_INIT_ZVAL(EX_T(opline->result.var).var.ptr);
+               MAKE_STD_ZVAL(EX_T(opline->result.var).var.ptr);
+               ZVAL_NULL(EX_T(opline->result.var).var.ptr);
 
                        /* Not sure what should be done here if it's a static method */
-               if (EX(object)) {
-                       Z_OBJ_HT_P(EX(object))->call_method(EX(function_state).function->common.function_name, opline->extended_value, EX_T(opline->result.var).var.ptr, &EX_T(opline->result.var).var.ptr, EX(object), RETURN_VALUE_USED(opline) TSRMLS_CC);
+               if (EXPECTED(EX(object) != NULL)) {
+                       Z_OBJ_HT_P(EX(object))->call_method(fbc->common.function_name, opline->extended_value, EX_T(opline->result.var).var.ptr, &EX_T(opline->result.var).var.ptr, EX(object), RETURN_VALUE_USED(opline) TSRMLS_CC);
                } else {
                        zend_error_noreturn(E_ERROR, "Cannot call overloaded function for non-object");
                }
 
-               if (EX(function_state).function->type == ZEND_OVERLOADED_FUNCTION_TEMPORARY) {
-                       efree(EX(function_state).function->common.function_name);
+               if (fbc->type == ZEND_OVERLOADED_FUNCTION_TEMPORARY) {
+                       efree(fbc->common.function_name);
                }
-               efree(EX(function_state).function);
+               efree(fbc);
 
                if (!RETURN_VALUE_USED(opline)) {
                        zval_ptr_dtor(&EX_T(opline->result.var).var.ptr);
@@ -2392,7 +2648,7 @@ ZEND_VM_HELPER(zend_do_fcall_common_helper, ANY, ANY)
 
        if (should_change_scope) {
                if (EG(This)) {
-                       if (EG(exception) && IS_CTOR_CALL(EX(called_scope))) {
+                       if (UNEXPECTED(EG(exception) != NULL) && IS_CTOR_CALL(EX(called_scope))) {
                                if (IS_CTOR_USED(EX(called_scope))) {
                                        Z_DELREF_P(EG(This));
                                }
@@ -2412,11 +2668,12 @@ ZEND_VM_HELPER(zend_do_fcall_common_helper, ANY, ANY)
 
        zend_vm_stack_clear_multiple(TSRMLS_C);
 
-       if (EG(exception)) {
+       if (UNEXPECTED(EG(exception) != NULL)) {
                zend_throw_exception_internal(NULL TSRMLS_CC);
                if (RETURN_VALUE_USED(opline) && EX_T(opline->result.var).var.ptr) {
                        zval_ptr_dtor(&EX_T(opline->result.var).var.ptr);
                }
+               HANDLE_EXCEPTION();
        }
 
        ZEND_VM_NEXT_OPCODE();
@@ -2430,13 +2687,14 @@ ZEND_VM_HANDLER(61, ZEND_DO_FCALL_BY_NAME, ANY, ANY)
 
 ZEND_VM_HANDLER(60, ZEND_DO_FCALL, CONST, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *fname = GET_OP1_ZVAL_PTR(BP_VAR_R);
 
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
-       if (zend_hash_quick_find(EG(function_table), Z_STRVAL_P(fname), Z_STRLEN_P(fname)+1, Z_HASH_P(fname), (void **) &EX(function_state).function)==FAILURE) {
+       if (UNEXPECTED(zend_hash_quick_find(EG(function_table), Z_STRVAL_P(fname), Z_STRLEN_P(fname)+1, Z_HASH_P(fname), (void **) &EX(function_state).function)==FAILURE)) {
+           SAVE_OPLINE();
                zend_error_noreturn(E_ERROR, "Call to undefined function %s()", fname->value.str.val);
        }
        EX(object) = NULL;
@@ -2448,12 +2706,13 @@ ZEND_VM_HANDLER(60, ZEND_DO_FCALL, CONST, ANY)
 
 ZEND_VM_HANDLER(62, ZEND_RETURN, CONST|TMP|VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *retval_ptr;
        zval **retval_ptr_ptr;
        zend_free_op free_op1;
 
-       if (EG(active_op_array)->return_reference == ZEND_RETURN_REF) {
+       SAVE_OPLINE();
+       if (UNEXPECTED(EG(active_op_array)->return_reference == ZEND_RETURN_REF)) {
 
                if (OP1_TYPE == IS_CONST || OP1_TYPE == IS_TMP_VAR) {
                        /* Not supposed to happen, but we'll allow it */
@@ -2463,7 +2722,7 @@ ZEND_VM_HANDLER(62, ZEND_RETURN, CONST|TMP|VAR|CV, ANY)
 
                retval_ptr_ptr = GET_OP1_ZVAL_PTR_PTR(BP_VAR_W);
 
-               if (OP1_TYPE == IS_VAR && !retval_ptr_ptr) {
+               if (OP1_TYPE == IS_VAR && UNEXPECTED(retval_ptr_ptr == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot return string offsets by reference");
                }
 
@@ -2485,6 +2744,8 @@ ZEND_VM_HANDLER(62, ZEND_RETURN, CONST|TMP|VAR|CV, ANY)
 
                        (*EG(return_value_ptr_ptr)) = (*retval_ptr_ptr);
                }
+               FREE_OP1_IF_VAR();
+               ZEND_VM_DISPATCH_TO_HELPER(zend_leave_helper);
        } else {
 ZEND_VM_C_LABEL(return_by_value):
 
@@ -2515,21 +2776,22 @@ ZEND_VM_C_LABEL(return_by_value):
                        INIT_PZVAL_COPY(ret, retval_ptr);
                        *EG(return_value_ptr_ptr) = ret;
                }
+               FREE_OP1_IF_VAR();
+               ZEND_VM_DISPATCH_TO_HELPER(zend_leave_helper);
        }
-       FREE_OP1_IF_VAR();
-       ZEND_VM_DISPATCH_TO_HELPER(zend_leave_helper);
 }
 
 ZEND_VM_HANDLER(108, ZEND_THROW, CONST|TMP|VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *value;
        zval *exception;
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        value = GET_OP1_ZVAL_PTR(BP_VAR_R);
 
-       if (OP1_TYPE == IS_CONST || Z_TYPE_P(value) != IS_OBJECT) {
+       if (OP1_TYPE == IS_CONST || UNEXPECTED(Z_TYPE_P(value) != IS_OBJECT)) {
                zend_error_noreturn(E_ERROR, "Can only throw objects");
        }
        zend_exception_save(TSRMLS_C);
@@ -2543,26 +2805,28 @@ ZEND_VM_HANDLER(108, ZEND_THROW, CONST|TMP|VAR|CV, ANY)
        zend_throw_exception_object(exception TSRMLS_CC);
        zend_exception_restore(TSRMLS_C);
        FREE_OP1_IF_VAR();
-       ZEND_VM_NEXT_OPCODE();
+       HANDLE_EXCEPTION();
 }
 
-ZEND_VM_HANDLER(107, ZEND_CATCH, ANY, CV)
+ZEND_VM_HANDLER(107, ZEND_CATCH, CONST, CV)
 {
-       zend_op *opline = EX(opline);
-       zend_class_entry *ce;
+       USE_OPLINE
+       zend_class_entry *ce, *catch_ce;
 
+       SAVE_OPLINE();
        /* Check whether an exception has been thrown, if not, jump over code */
        zend_exception_restore(TSRMLS_C);
        if (EG(exception) == NULL) {
                ZEND_VM_SET_OPCODE(&EX(op_array)->opcodes[opline->extended_value]);
                ZEND_VM_CONTINUE(); /* CHECK_ME */
        }
+       catch_ce = zend_fetch_class_by_name(Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), opline->op1.literal + 1, ZEND_FETCH_CLASS_NO_AUTOLOAD TSRMLS_CC);
        ce = Z_OBJCE_P(EG(exception));
-       if (ce != EX_T(opline->op1.var).class_entry) {
-               if (!instanceof_function(ce, EX_T(opline->op1.var).class_entry TSRMLS_CC)) {
+       if (ce != catch_ce) {
+               if (!instanceof_function(ce, catch_ce TSRMLS_CC)) {
                        if (opline->result.num) {
                                zend_throw_exception_internal(NULL TSRMLS_CC);
-                               ZEND_VM_NEXT_OPCODE();
+                               HANDLE_EXCEPTION();
                        }
                        ZEND_VM_SET_OPCODE(&EX(op_array)->opcodes[opline->extended_value]);
                        ZEND_VM_CONTINUE(); /* CHECK_ME */
@@ -2570,15 +2834,15 @@ ZEND_VM_HANDLER(107, ZEND_CATCH, ANY, CV)
        }
 
        if (!EG(active_symbol_table)) {
-               if (EX(CVs)[opline->op2.var]) {
-                       zval_ptr_dtor(EX(CVs)[opline->op2.var]);
+               if (EX_CV(opline->op2.var)) {
+                       zval_ptr_dtor(EX_CV(opline->op2.var));
                }
-               EX(CVs)[opline->op2.var] = (zval**)EX(CVs) + (EX(op_array)->last_var + opline->op2.var);
-               *EX(CVs)[opline->op2.var] = EG(exception);
+               EX_CV(opline->op2.var) = (zval**)EX_CVs() + (EX(op_array)->last_var + opline->op2.var);
+               *EX_CV(opline->op2.var) = EG(exception);
        } else {
                zend_compiled_variable *cv = &CV_DEF_OF(opline->op2.var);
                zend_hash_quick_update(EG(active_symbol_table), cv->name, cv->name_len+1, cv->hash_value,
-                   &EG(exception), sizeof(zval *), (void**)&EX(CVs)[opline->op2.var]);
+                   &EG(exception), sizeof(zval *), (void**)&EX_CV(opline->op2.var));
        }
        EG(exception) = NULL;
        ZEND_VM_NEXT_OPCODE();
@@ -2586,7 +2850,9 @@ ZEND_VM_HANDLER(107, ZEND_CATCH, ANY, CV)
 
 ZEND_VM_HANDLER(65, ZEND_SEND_VAL, CONST|TMP|VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       SAVE_OPLINE();
        if (opline->extended_value==ZEND_DO_FCALL_BY_NAME
                && ARG_MUST_BE_SENT_BY_REF(EX(fbc), opline->op2.opline_num)) {
                        zend_error_noreturn(E_ERROR, "Cannot pass parameter %d by reference", opline->op2.opline_num);
@@ -2606,12 +2872,13 @@ ZEND_VM_HANDLER(65, ZEND_SEND_VAL, CONST|TMP|VAR|CV, ANY)
                zend_vm_stack_push(valptr TSRMLS_CC);
                FREE_OP1_IF_VAR();
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HELPER(zend_send_by_var_helper, VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *varptr;
        zend_free_op free_op1;
        varptr = GET_OP1_ZVAL_PTR(BP_VAR_R);
@@ -2624,7 +2891,7 @@ ZEND_VM_HELPER(zend_send_by_var_helper, VAR|CV, ANY)
                zval *original_var = varptr;
 
                ALLOC_ZVAL(varptr);
-               *varptr = *original_var;
+               ZVAL_COPY_VALUE(varptr, original_var);
                Z_UNSET_ISREF_P(varptr);
                Z_SET_REFCOUNT_P(varptr, 0);
                zval_copy_ctor(varptr);
@@ -2633,15 +2900,17 @@ ZEND_VM_HELPER(zend_send_by_var_helper, VAR|CV, ANY)
        zend_vm_stack_push(varptr TSRMLS_CC);
        FREE_OP1();  /* for string offsets */
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(106, ZEND_SEND_VAR_NO_REF, VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *varptr;
 
+       SAVE_OPLINE();
        if (opline->extended_value & ZEND_ARG_COMPILE_TIME_BOUND) { /* Had function_ptr at compile_time */
                if (!(opline->extended_value & ZEND_ARG_SEND_BY_REF)) {
                        ZEND_VM_DISPATCH_TO_HELPER(zend_send_by_var_helper);
@@ -2683,24 +2952,27 @@ ZEND_VM_HANDLER(106, ZEND_SEND_VAR_NO_REF, VAR|CV, ANY)
                zend_vm_stack_push(valptr TSRMLS_CC);
        }
        FREE_OP1_IF_VAR();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(67, ZEND_SEND_REF, VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval **varptr_ptr;
        zval *varptr;
+
+       SAVE_OPLINE();
        varptr_ptr = GET_OP1_ZVAL_PTR_PTR(BP_VAR_W);
 
-       if (OP1_TYPE == IS_VAR && !varptr_ptr) {
+       if (OP1_TYPE == IS_VAR && UNEXPECTED(varptr_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Only variables can be passed by reference");
        }
 
-       if (EX(function_state).function->type == ZEND_INTERNAL_FUNCTION && !ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), opline->op2.opline_num)) {
-               ZEND_VM_DISPATCH_TO_HELPER(zend_send_by_var_helper);
-        }
+       if (EX(function_state).function->type == ZEND_INTERNAL_FUNCTION && !ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), opline->op2.opline_num)) {
+               ZEND_VM_DISPATCH_TO_HELPER(zend_send_by_var_helper);
+       }
 
        SEPARATE_ZVAL_TO_MAKE_IS_REF(varptr_ptr);
        varptr = *varptr_ptr;
@@ -2708,64 +2980,72 @@ ZEND_VM_HANDLER(67, ZEND_SEND_REF, VAR|CV, ANY)
        zend_vm_stack_push(varptr TSRMLS_CC);
 
        FREE_OP1_VAR_PTR();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(66, ZEND_SEND_VAR, VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        if ((opline->extended_value == ZEND_DO_FCALL_BY_NAME)
                && ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), opline->op2.opline_num)) {
                ZEND_VM_DISPATCH_TO_HANDLER(ZEND_SEND_REF);
        }
+       SAVE_OPLINE();
        ZEND_VM_DISPATCH_TO_HELPER(zend_send_by_var_helper);
 }
 
 ZEND_VM_HANDLER(63, ZEND_RECV, ANY, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_uint arg_num = opline->op1.num;
        zval **param = zend_vm_stack_get_arg(arg_num TSRMLS_CC);
 
-       if (param == NULL) {
-               char *space;
-               char *class_name = get_active_class_name(&space TSRMLS_CC);
-               zend_execute_data *ptr = EX(prev_execute_data);
-
+       SAVE_OPLINE();
+       if (UNEXPECTED(param == NULL)) {
                if (zend_verify_arg_type((zend_function *) EG(active_op_array), arg_num, NULL, opline->extended_value TSRMLS_CC)) {
+                       char *space;
+                       char *class_name;
+                       zend_execute_data *ptr;
+                       
+                       if (EG(active_op_array)->scope) {
+                               class_name = EG(active_op_array)->scope->name;
+                               space = "::";
+                       } else {
+                               class_name = space = "";
+                       }
+                       ptr = EX(prev_execute_data);
+
                        if(ptr && ptr->op_array) {
                                zend_error(E_WARNING, "Missing argument %u for %s%s%s(), called in %s on line %d and defined", opline->op1.num, class_name, space, get_active_function_name(TSRMLS_C), ptr->op_array->filename, ptr->opline->lineno);
                        } else {
                                zend_error(E_WARNING, "Missing argument %u for %s%s%s()", opline->op1.num, class_name, space, get_active_function_name(TSRMLS_C));
                        }
                }
-               if (opline->result_type == IS_VAR) {
-                       PZVAL_UNLOCK_FREE(*EX_T(opline->result.var).var.ptr_ptr);
-               }
        } else {
-               zend_free_op free_res;
                zval **var_ptr;
 
                zend_verify_arg_type((zend_function *) EG(active_op_array), arg_num, *param, opline->extended_value TSRMLS_CC);
-               var_ptr = get_zval_ptr_ptr(opline->result_type, &opline->result, EX(Ts), &free_res, BP_VAR_W);
+               var_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->result.var TSRMLS_CC);
                Z_DELREF_PP(var_ptr);
                *var_ptr = *param;
                Z_ADDREF_PP(var_ptr);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(64, ZEND_RECV_INIT, ANY, CONST)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *assignment_value;
        zend_uint arg_num = opline->op1.num;
-       zend_free_op free_res;
        zval **param = zend_vm_stack_get_arg(arg_num TSRMLS_CC);
        zval **var_ptr;
 
+       SAVE_OPLINE();
        if (param == NULL) {
                ALLOC_ZVAL(assignment_value);
                *assignment_value = *opline->op2.zv;
@@ -2783,46 +3063,51 @@ ZEND_VM_HANDLER(64, ZEND_RECV_INIT, ANY, CONST)
        }
 
        zend_verify_arg_type((zend_function *) EG(active_op_array), arg_num, assignment_value, opline->extended_value TSRMLS_CC);
-       var_ptr = get_zval_ptr_ptr(opline->result_type, &opline->result, EX(Ts), &free_res, BP_VAR_W);
+       var_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->result.var TSRMLS_CC);
        Z_DELREF_PP(var_ptr);
        *var_ptr = assignment_value;
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(52, ZEND_BOOL, CONST|TMP|VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
+       zval *retval = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        /* PHP 3.0 returned "" for false and 1 for true, here we use 0 and 1 for now */
-       Z_LVAL(EX_T(opline->result.var).tmp_var) = i_zend_is_true(GET_OP1_ZVAL_PTR(BP_VAR_R));
-       Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
+       ZVAL_BOOL(retval, i_zend_is_true(GET_OP1_ZVAL_PTR(BP_VAR_R)));
        FREE_OP1();
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(50, ZEND_BRK, ANY, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zend_brk_cont_element *el;
 
+       SAVE_OPLINE();
        el = zend_brk_cont(GET_OP2_ZVAL_PTR(BP_VAR_R), opline->op1.opline_num,
-                          EX(op_array), EX(Ts) TSRMLS_CC);
+                          EX(op_array), EX_Ts() TSRMLS_CC);
        FREE_OP2();
        ZEND_VM_JMP(EX(op_array)->opcodes + el->brk);
 }
 
 ZEND_VM_HANDLER(51, ZEND_CONT, ANY, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zend_brk_cont_element *el;
 
+       SAVE_OPLINE();
        el = zend_brk_cont(GET_OP2_ZVAL_PTR(BP_VAR_R), opline->op1.opline_num,
-                          EX(op_array), EX(Ts) TSRMLS_CC);
+                          EX(op_array), EX_Ts() TSRMLS_CC);
        FREE_OP2();
        ZEND_VM_JMP(EX(op_array)->opcodes + el->cont);
 }
@@ -2830,11 +3115,12 @@ ZEND_VM_HANDLER(51, ZEND_CONT, ANY, CONST|TMP|VAR|CV)
 ZEND_VM_HANDLER(100, ZEND_GOTO, ANY, CONST)
 {
        zend_op *brk_opline;
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_brk_cont_element *el;
 
+       SAVE_OPLINE();
        el = zend_brk_cont(opline->op2.zv, opline->extended_value,
-                          EX(op_array), EX(Ts) TSRMLS_CC);
+                          EX(op_array), EX_Ts() TSRMLS_CC);
 
        brk_opline = EX(op_array)->opcodes + el->brk;
 
@@ -2855,10 +3141,11 @@ ZEND_VM_HANDLER(100, ZEND_GOTO, ANY, CONST)
 
 ZEND_VM_HANDLER(48, ZEND_CASE, CONST|TMP|VAR|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        int switch_expr_is_overloaded=0;
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        if (OP1_TYPE==IS_VAR) {
                if (EX_T(opline->op1.var).var.ptr_ptr) {
                        PZVAL_LOCK(EX_T(opline->op1.var).var.ptr);
@@ -2882,24 +3169,28 @@ ZEND_VM_HANDLER(48, ZEND_CASE, CONST|TMP|VAR|CV, CONST|TMP|VAR|CV)
                EX_T(opline->op1.var).var.ptr_ptr = NULL;
                EX_T(opline->op1.var).var.ptr = NULL;
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(49, ZEND_SWITCH_FREE, VAR, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
+       SAVE_OPLINE();
        zend_switch_free(&EX_T(opline->op1.var), opline->extended_value TSRMLS_CC);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(68, ZEND_NEW, ANY, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *object_zval;
        zend_function *constructor;
 
-       if (EX_T(opline->op1.var).class_entry->ce_flags & (ZEND_ACC_INTERFACE|ZEND_ACC_IMPLICIT_ABSTRACT_CLASS|ZEND_ACC_EXPLICIT_ABSTRACT_CLASS)) {
+       SAVE_OPLINE();
+       if (UNEXPECTED((EX_T(opline->op1.var).class_entry->ce_flags & (ZEND_ACC_INTERFACE|ZEND_ACC_IMPLICIT_ABSTRACT_CLASS|ZEND_ACC_EXPLICIT_ABSTRACT_CLASS)) != 0)) {
                char *class_type;
 
                if (EX_T(opline->op1.var).class_entry->ce_flags & ZEND_ACC_INTERFACE) {
@@ -2917,15 +3208,15 @@ ZEND_VM_HANDLER(68, ZEND_NEW, ANY, ANY)
 
        if (constructor == NULL) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, object_zval);
+                       AI_SET_PTR(&EX_T(opline->result.var), object_zval);
                } else {
                        zval_ptr_dtor(&object_zval);
                }
                ZEND_VM_JMP(EX(op_array)->opcodes + opline->op2.opline_num);
        } else {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, object_zval);
                        PZVAL_LOCK(object_zval);
+                       AI_SET_PTR(&EX_T(opline->result.var), object_zval);
                }
 
                zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), ENCODE_CTOR(EX(called_scope), RETURN_VALUE_USED(opline)));
@@ -2935,29 +3226,33 @@ ZEND_VM_HANDLER(68, ZEND_NEW, ANY, ANY)
                EX(fbc) = constructor;
                EX(called_scope) = EX_T(opline->op1.var).class_entry;
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 }
 
 ZEND_VM_HANDLER(110, ZEND_CLONE, CONST|TMP|VAR|UNUSED|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *obj = GET_OP1_OBJ_ZVAL_PTR(BP_VAR_R);
+       zval *obj;
        zend_class_entry *ce;
        zend_function *clone;
        zend_object_clone_obj_t clone_call;
 
+       SAVE_OPLINE();
+       obj = GET_OP1_OBJ_ZVAL_PTR(BP_VAR_R);
+
        if (OP1_TYPE == IS_CONST ||
-           (OP1_TYPE == IS_VAR && !obj) ||
-           Z_TYPE_P(obj) != IS_OBJECT) {
+           (OP1_TYPE == IS_VAR && UNEXPECTED(obj == NULL)) ||
+           UNEXPECTED(Z_TYPE_P(obj) != IS_OBJECT)) {
                zend_error_noreturn(E_ERROR, "__clone method called on non-object");
        }
 
        ce = Z_OBJCE_P(obj);
        clone = ce ? ce->clone : NULL;
        clone_call =  Z_OBJ_HT_P(obj)->clone_obj;
-       if (!clone_call) {
+       if (UNEXPECTED(clone_call == NULL)) {
                if (ce) {
                        zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object of class %s", ce->name);
                } else {
@@ -2969,37 +3264,42 @@ ZEND_VM_HANDLER(110, ZEND_CLONE, CONST|TMP|VAR|UNUSED|CV, ANY)
                if (clone->op_array.fn_flags & ZEND_ACC_PRIVATE) {
                        /* Ensure that if we're calling a private function, we're allowed to do so.
                         */
-                       if (ce != EG(scope)) {
+                       if (UNEXPECTED(ce != EG(scope))) {
                                zend_error_noreturn(E_ERROR, "Call to private %s::__clone() from context '%s'", ce->name, EG(scope) ? EG(scope)->name : "");
                        }
                } else if ((clone->common.fn_flags & ZEND_ACC_PROTECTED)) {
                        /* Ensure that if we're calling a protected function, we're allowed to do so.
                         */
-                       if (!zend_check_protected(clone->common.scope, EG(scope))) {
+                       if (UNEXPECTED(!zend_check_protected(clone->common.scope, EG(scope)))) {
                                zend_error_noreturn(E_ERROR, "Call to protected %s::__clone() from context '%s'", ce->name, EG(scope) ? EG(scope)->name : "");
                        }
                }
        }
 
-       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-       if (!EG(exception)) {
-               ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-               Z_OBJVAL_P(EX_T(opline->result.var).var.ptr) = clone_call(obj TSRMLS_CC);
-               Z_TYPE_P(EX_T(opline->result.var).var.ptr) = IS_OBJECT;
-               Z_SET_REFCOUNT_P(EX_T(opline->result.var).var.ptr, 1);
-               Z_SET_ISREF_P(EX_T(opline->result.var).var.ptr);
-               if (!RETURN_VALUE_USED(opline) || EG(exception)) {
-                       zval_ptr_dtor(&EX_T(opline->result.var).var.ptr);
+       if (EXPECTED(EG(exception) == NULL)) {
+               zval *retval;
+
+               ALLOC_ZVAL(retval);
+               Z_OBJVAL_P(retval) = clone_call(obj TSRMLS_CC);
+               Z_TYPE_P(retval) = IS_OBJECT;
+               Z_SET_REFCOUNT_P(retval, 1);
+               Z_SET_ISREF_P(retval);
+               if (!RETURN_VALUE_USED(opline) || UNEXPECTED(EG(exception) != NULL)) {
+                       zval_ptr_dtor(&retval);
+               } else {
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                }
        }
        FREE_OP1_IF_VAR();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(99, ZEND_FETCH_CONSTANT, VAR|CONST|UNUSED, CONST)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
+       SAVE_OPLINE();
        if (OP1_TYPE == IS_UNUSED) {
                /* namespaced constant */
                if (!zend_get_constant_ex(Z_STRVAL_P(opline->op2.zv), Z_STRLEN_P(opline->op2.zv), &EX_T(opline->result.var).tmp_var, NULL, opline->extended_value TSRMLS_CC)) {
@@ -3014,10 +3314,10 @@ ZEND_VM_HANDLER(99, ZEND_FETCH_CONSTANT, VAR|CONST|UNUSED, CONST)
                                zend_error(E_NOTICE, "Use of undefined constant %s - assumed '%s'", actual, actual);
                                ZVAL_STRINGL(&EX_T(opline->result.var).tmp_var, actual, Z_STRLEN_P(opline->op2.zv)-(actual - Z_STRVAL_P(opline->op2.zv)), 1);
                        } else {
-                               zend_error_noreturn(E_ERROR, "Undefined constant '%s'",
-                                                       Z_STRVAL_P(opline->op2.zv), Z_STRVAL_P(opline->op2.zv));
+                               zend_error_noreturn(E_ERROR, "Undefined constant '%s'", Z_STRVAL_P(opline->op2.zv));
                        }
                }
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
                /* class constant */
@@ -3027,14 +3327,14 @@ ZEND_VM_HANDLER(99, ZEND_FETCH_CONSTANT, VAR|CONST|UNUSED, CONST)
                if (OP1_TYPE == IS_CONST) {
 
                        ce = zend_fetch_class_by_name(Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), opline->op1.literal + 1, opline->extended_value TSRMLS_CC);
-                       if (!ce) {
+                       if (UNEXPECTED(ce == NULL)) {
                                zend_error_noreturn(E_ERROR, "Undefined class constant '%s'", Z_STRVAL_P(opline->op2.zv));
                        }
                } else {
                        ce = EX_T(opline->op1.var).class_entry;
                }
 
-               if (zend_hash_quick_find(&ce->constants_table, Z_STRVAL_P(opline->op2.zv), Z_STRLEN_P(opline->op2.zv)+1, Z_HASH_P(opline->op2.zv), (void **) &value) == SUCCESS) {
+               if (EXPECTED(zend_hash_quick_find(&ce->constants_table, Z_STRVAL_P(opline->op2.zv), Z_STRLEN_P(opline->op2.zv)+1, Z_HASH_P(opline->op2.zv), (void **) &value) == SUCCESS)) {
                        if (Z_TYPE_PP(value) == IS_CONSTANT_ARRAY ||
                            (Z_TYPE_PP(value) & IS_CONSTANT_TYPE_MASK) == IS_CONSTANT) {
                                zend_class_entry *old_scope = EG(scope);
@@ -3043,54 +3343,39 @@ ZEND_VM_HANDLER(99, ZEND_FETCH_CONSTANT, VAR|CONST|UNUSED, CONST)
                                zval_update_constant(value, (void *) 1 TSRMLS_CC);
                                EG(scope) = old_scope;
                        }
-                       EX_T(opline->result.var).tmp_var = **value;
+                       ZVAL_COPY_VALUE(&EX_T(opline->result.var).tmp_var, *value);
                        zval_copy_ctor(&EX_T(opline->result.var).tmp_var);
                } else {
                        zend_error_noreturn(E_ERROR, "Undefined class constant '%s'", Z_STRVAL_P(opline->op2.zv));
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 }
 
 ZEND_VM_HANDLER(72, ZEND_ADD_ARRAY_ELEMENT, CONST|TMP|VAR|CV, CONST|TMP|VAR|UNUSED|CV)
 {
-       zend_op *opline = EX(opline);
-       zend_free_op free_op1, free_op2;
-       zval *array_ptr = &EX_T(opline->result.var).tmp_var;
+       USE_OPLINE
+       zend_free_op free_op1;
        zval *expr_ptr;
-       zval *offset=GET_OP2_ZVAL_PTR(BP_VAR_R);
-       ulong hval;
-       long index;
 
-#if !defined(ZEND_VM_SPEC) || OP1_TYPE == IS_VAR || OP1_TYPE == IS_CV
-       zval **expr_ptr_ptr = NULL;
+       SAVE_OPLINE();
+       if ((OP1_TYPE == IS_VAR || OP1_TYPE == IS_CV) && opline->extended_value) {
+               zval **expr_ptr_ptr = GET_OP1_ZVAL_PTR_PTR(BP_VAR_W);
 
-       if (opline->extended_value) {
-               expr_ptr_ptr=GET_OP1_ZVAL_PTR_PTR(BP_VAR_W);
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
                expr_ptr = *expr_ptr_ptr;
+               Z_ADDREF_P(expr_ptr);
        } else {
                expr_ptr=GET_OP1_ZVAL_PTR(BP_VAR_R);
-       }
-#else
-       expr_ptr=GET_OP1_ZVAL_PTR(BP_VAR_R);
-#endif
-
-       if (IS_OP1_TMP_FREE()) { /* temporary variable */
-               zval *new_expr;
+               if (IS_OP1_TMP_FREE()) { /* temporary variable */
+                       zval *new_expr;
 
-               ALLOC_ZVAL(new_expr);
-               INIT_PZVAL_COPY(new_expr, expr_ptr);
-               expr_ptr = new_expr;
-       } else {
-#if !defined(ZEND_VM_SPEC) || OP1_TYPE == IS_VAR || OP1_TYPE == IS_CV
-               if (opline->extended_value) {
-                       SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
-                       expr_ptr = *expr_ptr_ptr;
-                       Z_ADDREF_P(expr_ptr);
-               } else
-#endif
-               if (OP1_TYPE == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
+                       ALLOC_ZVAL(new_expr);
+                       INIT_PZVAL_COPY(new_expr, expr_ptr);
+                       expr_ptr = new_expr;
+               } else if (OP1_TYPE == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
                        zval *new_expr;
 
                        ALLOC_ZVAL(new_expr);
@@ -3101,7 +3386,13 @@ ZEND_VM_HANDLER(72, ZEND_ADD_ARRAY_ELEMENT, CONST|TMP|VAR|CV, CONST|TMP|VAR|UNUS
                        Z_ADDREF_P(expr_ptr);
                }
        }
-       if (offset) {
+
+       if (OP2_TYPE != IS_UNUSED) {
+               zend_free_op free_op2;
+               zval *offset = GET_OP2_ZVAL_PTR(BP_VAR_R);
+               ulong hval;
+               long index;
+               
                switch (Z_TYPE_P(offset)) {
                        case IS_DOUBLE:
                                index = zend_dval_to_lval(Z_DVAL_P(offset));
@@ -3110,7 +3401,7 @@ ZEND_VM_HANDLER(72, ZEND_ADD_ARRAY_ELEMENT, CONST|TMP|VAR|CV, CONST|TMP|VAR|UNUS
                        case IS_BOOL:
                                index = Z_LVAL_P(offset);
 ZEND_VM_C_LABEL(num_index):
-                               zend_hash_index_update(Z_ARRVAL_P(array_ptr), index, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_index_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), index, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_STRING:
                                if (OP2_TYPE == IS_CONST) {
@@ -3123,10 +3414,10 @@ ZEND_VM_C_LABEL(num_index):
                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                        }
                                }
-                               zend_hash_quick_update(Z_ARRVAL_P(array_ptr), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_quick_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_NULL:
-                               zend_hash_update(Z_ARRVAL_P(array_ptr), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
                                break;
                        default:
                                zend_error(E_WARNING, "Illegal offset type");
@@ -3136,19 +3427,20 @@ ZEND_VM_C_LABEL(num_index):
                }
                FREE_OP2();
        } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(array_ptr), &expr_ptr, sizeof(zval *), NULL);
+               zend_hash_next_index_insert(Z_ARRVAL(EX_T(opline->result.var).tmp_var), &expr_ptr, sizeof(zval *), NULL);
        }
-       if (opline->extended_value) {
+       if ((OP1_TYPE == IS_VAR || OP1_TYPE == IS_CV) && opline->extended_value) {
                FREE_OP1_VAR_PTR();
        } else {
                FREE_OP1_IF_VAR();
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(71, ZEND_INIT_ARRAY, CONST|TMP|VAR|UNUSED|CV, CONST|TMP|VAR|UNUSED|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (OP1_TYPE == IS_UNUSED) {
@@ -3162,13 +3454,16 @@ ZEND_VM_HANDLER(71, ZEND_INIT_ARRAY, CONST|TMP|VAR|UNUSED|CV, CONST|TMP|VAR|UNUS
 
 ZEND_VM_HANDLER(21, ZEND_CAST, CONST|TMP|VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *expr = GET_OP1_ZVAL_PTR(BP_VAR_R);
+       zval *expr;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
+       expr = GET_OP1_ZVAL_PTR(BP_VAR_R);
+
        if (opline->extended_value != IS_STRING) {
-               *result = *expr;
+               ZVAL_COPY_VALUE(result, expr);
                if (!IS_OP1_TMP_FREE()) {
                        zendi_zval_copy_ctor(*result);
                }
@@ -3192,12 +3487,12 @@ ZEND_VM_HANDLER(21, ZEND_CAST, CONST|TMP|VAR|CV, ANY)
 
                        zend_make_printable_zval(expr, &var_copy, &use_copy);
                        if (use_copy) {
-                               *result = var_copy;
+                               ZVAL_COPY_VALUE(result, &var_copy);
                                if (IS_OP1_TMP_FREE()) {
                                        FREE_OP1();
                                }
                        } else {
-                               *result = *expr;
+                               ZVAL_COPY_VALUE(result, expr);
                                if (!IS_OP1_TMP_FREE()) {
                                        zendi_zval_copy_ctor(*result);
                                }
@@ -3212,28 +3507,29 @@ ZEND_VM_HANDLER(21, ZEND_CAST, CONST|TMP|VAR|CV, ANY)
                        break;
        }
        FREE_OP1_IF_VAR();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(73, ZEND_INCLUDE_OR_EVAL, CONST|TMP|VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_op_array *new_op_array=NULL;
-       int return_value_used;
        zend_free_op free_op1;
-       zval *inc_filename = GET_OP1_ZVAL_PTR(BP_VAR_R);
+       zval *inc_filename;
        zval tmp_inc_filename;
        zend_bool failure_retval=0;
 
+       SAVE_OPLINE();
+       inc_filename = GET_OP1_ZVAL_PTR(BP_VAR_R);
+
        if (inc_filename->type!=IS_STRING) {
-               tmp_inc_filename = *inc_filename;
+               ZVAL_COPY_VALUE(&tmp_inc_filename, inc_filename);
                zval_copy_ctor(&tmp_inc_filename);
                convert_to_string(&tmp_inc_filename);
                inc_filename = &tmp_inc_filename;
        }
 
-       return_value_used = RETURN_VALUE_USED(opline);
-
        switch (opline->extended_value) {
                case ZEND_INCLUDE_ONCE:
                case ZEND_REQUIRE_ONCE: {
@@ -3291,12 +3587,18 @@ ZEND_VM_HANDLER(73, ZEND_INCLUDE_OR_EVAL, CONST|TMP|VAR|CV, ANY)
                zval_dtor(&tmp_inc_filename);
        }
        FREE_OP1();
-       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-       if (new_op_array && !EG(exception)) {
+       if (UNEXPECTED(EG(exception) != NULL)) {
+               HANDLE_EXCEPTION();
+       } else if (EXPECTED(new_op_array != NULL)) {
                EX(original_return_value) = EG(return_value_ptr_ptr);
-               EG(return_value_ptr_ptr) = return_value_used ? EX_T(opline->result.var).var.ptr_ptr : NULL;
                EG(active_op_array) = new_op_array;
-               EX_T(opline->result.var).var.ptr = NULL;
+               if (RETURN_VALUE_USED(opline)) {
+                       EX_T(opline->result.var).var.ptr = NULL;
+                       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
+                       EG(return_value_ptr_ptr) = EX_T(opline->result.var).var.ptr_ptr;
+               } else {
+                       EG(return_value_ptr_ptr) = NULL;
+               }
 
                EX(current_object) = EX(object);
 
@@ -3307,8 +3609,7 @@ ZEND_VM_HANDLER(73, ZEND_INCLUDE_OR_EVAL, CONST|TMP|VAR|CV, ANY)
                        zend_rebuild_symbol_table(TSRMLS_C);
                }
 
-               if (zend_execute == execute) {
-                       EX(call_opline) = opline;
+               if (EXPECTED(zend_execute == execute)) {
                        ZEND_VM_ENTER();
                } else {
                        zend_execute(new_op_array TSRMLS_CC);
@@ -3317,75 +3618,62 @@ ZEND_VM_HANDLER(73, ZEND_INCLUDE_OR_EVAL, CONST|TMP|VAR|CV, ANY)
                EX(function_state).function = (zend_function *) EX(op_array);
                EX(object) = EX(current_object);
 
-               if (return_value_used) {
-                       if (!EX_T(opline->result.var).var.ptr) { /* there was no return statement */
-                               ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                               INIT_PZVAL(EX_T(opline->result.var).var.ptr);
-                               Z_LVAL_P(EX_T(opline->result.var).var.ptr) = 1;
-                               Z_TYPE_P(EX_T(opline->result.var).var.ptr) = IS_BOOL;
-                       }
-               }
-
                EG(opline_ptr) = &EX(opline);
                EG(active_op_array) = EX(op_array);
                EG(return_value_ptr_ptr) = EX(original_return_value);
                destroy_op_array(new_op_array TSRMLS_CC);
                efree(new_op_array);
-               if (EG(exception)) {
+               if (UNEXPECTED(EG(exception) != NULL)) {
                        zend_throw_exception_internal(NULL TSRMLS_CC);
+                       HANDLE_EXCEPTION();
+               } else if (RETURN_VALUE_USED(opline)) {
+                       if (!EX_T(opline->result.var).var.ptr) { /* there was no return statement */
+                               zval *retval;
+
+                               ALLOC_ZVAL(retval);
+                               ZVAL_BOOL(retval, 1);
+                               INIT_PZVAL(retval);
+                               EX_T(opline->result.var).var.ptr = retval;
+                       }
                }
-       } else {
-               if (return_value_used) {
-                       ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                       INIT_ZVAL(*EX_T(opline->result.var).var.ptr);
-                       Z_LVAL_P(EX_T(opline->result.var).var.ptr) = failure_retval;
-                       Z_TYPE_P(EX_T(opline->result.var).var.ptr) = IS_BOOL;
-               }
+
+       } else if (RETURN_VALUE_USED(opline)) {
+               zval *retval;
+
+               ALLOC_ZVAL(retval);
+               ZVAL_BOOL(retval, failure_retval);
+               INIT_PZVAL(retval);
+               AI_SET_PTR(&EX_T(opline->result.var), retval);
        }
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(74, ZEND_UNSET_VAR, CONST|TMP|VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval tmp, *varname;
        HashTable *target_symbol_table;
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        if (OP1_TYPE == IS_CV && (opline->extended_value & ZEND_QUICK_SET)) {
                if (EG(active_symbol_table)) {
-                       zend_execute_data *ex = EX(prev_execute_data);
                        zend_compiled_variable *cv = &CV_DEF_OF(opline->op1.var);
 
-                       if (zend_hash_quick_del(EG(active_symbol_table), cv->name, cv->name_len+1, cv->hash_value) == SUCCESS) {
-                               while (ex && ex->symbol_table == EG(active_symbol_table)) {
-                                       int i;
-
-                                       if (ex->op_array) {
-                                               for (i = 0; i < ex->op_array->last_var; i++) {
-                                                       if (ex->op_array->vars[i].hash_value == cv->hash_value &&
-                                                               ex->op_array->vars[i].name_len == cv->name_len &&
-                                                               !memcmp(ex->op_array->vars[i].name, cv->name, cv->name_len)) {
-                                                               ex->CVs[i] = NULL;
-                                                               break;
-                                                       }
-                                               }
-                                       }
-                                       ex = ex->prev_execute_data;
-                               }
-                       }
-                       EX(CVs)[opline->op1.var] = NULL;
-               } else if (EX(CVs)[opline->op1.var]) {
-                       zval_ptr_dtor(EX(CVs)[opline->op1.var]);
-                       EX(CVs)[opline->op1.var] = NULL;
+                       zend_delete_variable(EX(prev_execute_data), EG(active_symbol_table),  cv->name, cv->name_len+1, cv->hash_value TSRMLS_CC);
+                       EX_CV(opline->op1.var) = NULL;
+               } else if (EX_CV(opline->op1.var)) {
+                       zval_ptr_dtor(EX_CV(opline->op1.var));
+                       EX_CV(opline->op1.var) = NULL;
                }
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
        varname = GET_OP1_ZVAL_PTR(BP_VAR_R);
 
        if (OP1_TYPE != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-               tmp = *varname;
+               ZVAL_COPY_VALUE(&tmp, varname);
                zval_copy_ctor(&tmp);
                convert_to_string(&tmp);
                varname = &tmp;
@@ -3399,45 +3687,32 @@ ZEND_VM_HANDLER(74, ZEND_UNSET_VAR, CONST|TMP|VAR|CV, ANY)
                ulong hash_value = zend_inline_hash_func(varname->value.str.val, varname->value.str.len+1);
 
                target_symbol_table = zend_get_target_symbol_table(opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-               if (zend_hash_quick_del(target_symbol_table, varname->value.str.val, varname->value.str.len+1, hash_value) == SUCCESS) {
-                       zend_execute_data *ex = EXECUTE_DATA;
-
-                       do {
-                               int i;
-
-                               if (ex->op_array) {
-                                       for (i = 0; i < ex->op_array->last_var; i++) {
-                                               if (ex->op_array->vars[i].hash_value == hash_value &&
-                                                       ex->op_array->vars[i].name_len == varname->value.str.len &&
-                                                       !memcmp(ex->op_array->vars[i].name, varname->value.str.val, varname->value.str.len)) {
-                                                       ex->CVs[i] = NULL;
-                                                       break;
-                                               }
-                                       }
-                               }
-                               ex = ex->prev_execute_data;
-                       } while (ex && ex->symbol_table == target_symbol_table);
-               }
+               zend_delete_variable(EXECUTE_DATA, target_symbol_table, varname->value.str.val, varname->value.str.len+1, hash_value TSRMLS_CC);
        }
 
-       if (varname == &tmp) {
+       if (OP1_TYPE != IS_CONST && varname == &tmp) {
                zval_dtor(&tmp);
        } else if (OP1_TYPE == IS_VAR || OP1_TYPE == IS_CV) {
                zval_ptr_dtor(&varname);
        }
        FREE_OP1();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(75, ZEND_UNSET_DIM, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval **container = GET_OP1_OBJ_ZVAL_PTR_PTR(BP_VAR_UNSET);
-       zval *offset = GET_OP2_ZVAL_PTR(BP_VAR_R);
+       zval **container;
+       zval *offset;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = GET_OP1_OBJ_ZVAL_PTR_PTR(BP_VAR_UNSET);
+       offset = GET_OP2_ZVAL_PTR(BP_VAR_R);
+       
        if (OP1_TYPE != IS_VAR || container) {
                if (OP1_TYPE == IS_CV && container != &EG(uninitialized_zval_ptr)) {
                        SEPARATE_ZVAL_IF_NOT_REF(container);
@@ -3471,24 +3746,10 @@ ZEND_VM_C_LABEL(num_index_dim):
                                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                                        }
                                                }
-                                               if (zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval) == SUCCESS &&
-                                           ht == &EG(symbol_table)) {
-                                                       zend_execute_data *ex;
-
-                                                       for (ex = EXECUTE_DATA; ex; ex = ex->prev_execute_data) {
-                                                               if (ex->op_array && ex->symbol_table == ht) {
-                                                                       int i;
-
-                                                                       for (i = 0; i < ex->op_array->last_var; i++) {
-                                                                               if (ex->op_array->vars[i].hash_value == hval &&
-                                                                                   ex->op_array->vars[i].name_len == offset->value.str.len &&
-                                                                                   !memcmp(ex->op_array->vars[i].name, offset->value.str.val, offset->value.str.len)) {
-                                                                                       ex->CVs[i] = NULL;
-                                                                                       break;
-                                                                               }
-                                                                       }
-                                                               }
-                                                       }
+                                               if (ht == &EG(symbol_table)) {
+                                                       zend_delete_global_variable_ex(offset->value.str.val, offset->value.str.len, hval TSRMLS_CC);
+                                               } else {
+                                                       zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval);
                                                }
                                                if (OP2_TYPE == IS_CV || OP2_TYPE == IS_VAR) {
                                                        zval_ptr_dtor(&offset);
@@ -3505,7 +3766,7 @@ ZEND_VM_C_LABEL(num_index_dim):
                                break;
                        }
                        case IS_OBJECT:
-                               if (!Z_OBJ_HT_P(*container)->unset_dimension) {
+                               if (UNEXPECTED(Z_OBJ_HT_P(*container)->unset_dimension == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use object as array");
                                }
                                if (IS_OP2_TMP_FREE()) {
@@ -3530,15 +3791,20 @@ ZEND_VM_C_LABEL(num_index_dim):
        }
        FREE_OP1_VAR_PTR();
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(76, ZEND_UNSET_OBJ, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval **container = GET_OP1_OBJ_ZVAL_PTR_PTR(BP_VAR_UNSET);
-       zval *offset = GET_OP2_ZVAL_PTR(BP_VAR_R);
+       zval **container;
+       zval *offset;
+
+       SAVE_OPLINE();
+       container = GET_OP1_OBJ_ZVAL_PTR_PTR(BP_VAR_UNSET);
+       offset = GET_OP2_ZVAL_PTR(BP_VAR_R);
 
        if (OP1_TYPE != IS_VAR || container) {
                if (OP1_TYPE == IS_CV && container != &EG(uninitialized_zval_ptr)) {
@@ -3566,12 +3832,13 @@ ZEND_VM_HANDLER(76, ZEND_UNSET_OBJ, VAR|UNUSED|CV, CONST|TMP|VAR|CV)
        }
        FREE_OP1_VAR_PTR();
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(77, ZEND_FE_RESET, CONST|TMP|VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *array_ptr, **array_ptr_ptr;
        HashTable *fe_ht;
@@ -3579,10 +3846,13 @@ ZEND_VM_HANDLER(77, ZEND_FE_RESET, CONST|TMP|VAR|CV, ANY)
        zend_class_entry *ce = NULL;
        zend_bool is_empty = 0;
 
+       SAVE_OPLINE();
+
        if (opline->extended_value & ZEND_FE_RESET_VARIABLE) {
                array_ptr_ptr = GET_OP1_ZVAL_PTR_PTR(BP_VAR_R);
                if (array_ptr_ptr == NULL || array_ptr_ptr == &EG(uninitialized_zval_ptr)) {
-                       ALLOC_INIT_ZVAL(array_ptr);
+                       MAKE_STD_ZVAL(array_ptr);
+                       ZVAL_NULL(array_ptr);
                } else if (Z_TYPE_PP(array_ptr_ptr) == IS_OBJECT) {
                        if(Z_OBJ_HT_PP(array_ptr_ptr)->get_class_entry == NULL) {
                                zend_error(E_WARNING, "foreach() cannot iterate over objects without PHP class");
@@ -3642,7 +3912,7 @@ ZEND_VM_HANDLER(77, ZEND_FE_RESET, CONST|TMP|VAR|CV, ANY)
        if (ce && ce->get_iterator) {
                iter = ce->get_iterator(ce, array_ptr, opline->extended_value & ZEND_FE_RESET_REFERENCE TSRMLS_CC);
 
-               if (iter && !EG(exception)) {
+               if (iter && EXPECTED(EG(exception) == NULL)) {
                        array_ptr = zend_iterator_wrap(iter TSRMLS_CC);
                } else {
                        if (opline->extended_value & ZEND_FE_RESET_VARIABLE) {
@@ -3654,18 +3924,18 @@ ZEND_VM_HANDLER(77, ZEND_FE_RESET, CONST|TMP|VAR|CV, ANY)
                                zend_throw_exception_ex(NULL, 0 TSRMLS_CC, "Object of type %s did not create an Iterator", ce->name);
                        }
                        zend_throw_exception_internal(NULL TSRMLS_CC);
-                       ZEND_VM_NEXT_OPCODE();
+                       HANDLE_EXCEPTION();
                }
        }
 
-       AI_SET_PTR(EX_T(opline->result.var).var, array_ptr);
        PZVAL_LOCK(array_ptr);
+       AI_SET_PTR(&EX_T(opline->result.var), array_ptr);
 
        if (iter) {
                iter->index = 0;
                if (iter->funcs->rewind) {
                        iter->funcs->rewind(iter TSRMLS_CC);
-                       if (EG(exception)) {
+                       if (UNEXPECTED(EG(exception) != NULL)) {
                                Z_DELREF_P(array_ptr);
                                zval_ptr_dtor(&array_ptr);
                                if (opline->extended_value & ZEND_FE_RESET_VARIABLE) {
@@ -3673,11 +3943,11 @@ ZEND_VM_HANDLER(77, ZEND_FE_RESET, CONST|TMP|VAR|CV, ANY)
                                } else {
                                        FREE_OP1_IF_VAR();
                                }
-                               ZEND_VM_NEXT_OPCODE();
+                               HANDLE_EXCEPTION();
                        }
                }
                is_empty = iter->funcs->valid(iter TSRMLS_CC) != SUCCESS;
-               if (EG(exception)) {
+               if (UNEXPECTED(EG(exception) != NULL)) {
                        Z_DELREF_P(array_ptr);
                        zval_ptr_dtor(&array_ptr);
                        if (opline->extended_value & ZEND_FE_RESET_VARIABLE) {
@@ -3685,7 +3955,7 @@ ZEND_VM_HANDLER(77, ZEND_FE_RESET, CONST|TMP|VAR|CV, ANY)
                        } else {
                                FREE_OP1_IF_VAR();
                        }
-                       ZEND_VM_NEXT_OPCODE();
+                       HANDLE_EXCEPTION();
                }
                iter->index = -1; /* will be set to 0 before using next handler */
        } else if ((fe_ht = HASH_OF(array_ptr)) != NULL) {
@@ -3722,13 +3992,14 @@ ZEND_VM_HANDLER(77, ZEND_FE_RESET, CONST|TMP|VAR|CV, ANY)
        if (is_empty) {
                ZEND_VM_JMP(EX(op_array)->opcodes+opline->op2.opline_num);
        } else {
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 }
 
 ZEND_VM_HANDLER(78, ZEND_FE_FETCH, VAR, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *array = EX_T(opline->op1.var).var.ptr;
        zval **value;
@@ -3740,6 +4011,8 @@ ZEND_VM_HANDLER(78, ZEND_FE_FETCH, VAR, ANY)
        int key_type = 0;
        zend_bool use_key = (zend_bool)(opline->extended_value & ZEND_FE_FETCH_WITH_KEY);
 
+       SAVE_OPLINE();
+
        switch (zend_iterator_unwrap(array, &iter TSRMLS_CC)) {
                default:
                case ZEND_ITER_INVALID:
@@ -3750,7 +4023,7 @@ ZEND_VM_HANDLER(78, ZEND_FE_FETCH, VAR, ANY)
                        char *class_name, *prop_name;
                        zend_object *zobj = zend_objects_get_address(array TSRMLS_CC);
 
-                       fe_ht = HASH_OF(array);
+                       fe_ht = Z_OBJPROP_P(array);
                        zend_hash_set_pointer(fe_ht, &EX_T(opline->op1.var).fe.fe_pos);
                        do {
                                if (zend_hash_get_current_data(fe_ht, (void **) &value)==FAILURE) {
@@ -3774,7 +4047,7 @@ ZEND_VM_HANDLER(78, ZEND_FE_FETCH, VAR, ANY)
                }
 
                case ZEND_ITER_PLAIN_ARRAY:
-                       fe_ht = HASH_OF(array);
+                       fe_ht = Z_ARRVAL_P(array);
                        zend_hash_set_pointer(fe_ht, &EX_T(opline->op1.var).fe.fe_pos);
                        if (zend_hash_get_current_data(fe_ht, (void **) &value)==FAILURE) {
                                /* reached end of iteration */
@@ -3793,27 +4066,27 @@ ZEND_VM_HANDLER(78, ZEND_FE_FETCH, VAR, ANY)
                                /* This could cause an endless loop if index becomes zero again.
                                 * In case that ever happens we need an additional flag. */
                                iter->funcs->move_forward(iter TSRMLS_CC);
-                               if (EG(exception)) {
+                               if (UNEXPECTED(EG(exception) != NULL)) {
                                        Z_DELREF_P(array);
                                        zval_ptr_dtor(&array);
-                                       ZEND_VM_NEXT_OPCODE();
+                                       HANDLE_EXCEPTION();
                                }
                        }
                        /* If index is zero we come from FE_RESET and checked valid() already. */
                        if (!iter || (iter->index > 0 && iter->funcs->valid(iter TSRMLS_CC) == FAILURE)) {
                                /* reached end of iteration */
-                               if (EG(exception)) {
+                               if (UNEXPECTED(EG(exception) != NULL)) {
                                        Z_DELREF_P(array);
                                        zval_ptr_dtor(&array);
-                                       ZEND_VM_NEXT_OPCODE();
+                                       HANDLE_EXCEPTION();
                                }
                                ZEND_VM_JMP(EX(op_array)->opcodes+opline->op2.opline_num);
                        }
                        iter->funcs->get_current_data(iter, &value TSRMLS_CC);
-                       if (EG(exception)) {
+                       if (UNEXPECTED(EG(exception) != NULL)) {
                                Z_DELREF_P(array);
                                zval_ptr_dtor(&array);
-                               ZEND_VM_NEXT_OPCODE();
+                               HANDLE_EXCEPTION();
                        }
                        if (!value) {
                                /* failure in get_current_data */
@@ -3822,10 +4095,10 @@ ZEND_VM_HANDLER(78, ZEND_FE_FETCH, VAR, ANY)
                        if (use_key) {
                                if (iter->funcs->get_current_key) {
                                        key_type = iter->funcs->get_current_key(iter, &str_key, &str_key_len, &int_key TSRMLS_CC);
-                                       if (EG(exception)) {
+                                       if (UNEXPECTED(EG(exception) != NULL)) {
                                                Z_DELREF_P(array);
                                                zval_ptr_dtor(&array);
-                                               ZEND_VM_NEXT_OPCODE();
+                                               HANDLE_EXCEPTION();
                                        }
                                } else {
                                        key_type = HASH_KEY_IS_LONG;
@@ -3841,13 +4114,12 @@ ZEND_VM_HANDLER(78, ZEND_FE_FETCH, VAR, ANY)
                EX_T(opline->result.var).var.ptr_ptr = value;
                Z_ADDREF_PP(value);
        } else {
-               AI_SET_PTR(EX_T(opline->result.var).var, *value);
                PZVAL_LOCK(*value);
+               AI_SET_PTR(&EX_T(opline->result.var), *value);
        }
 
        if (use_key) {
-               zend_op *op_data = opline+1;
-               zval *key = &EX_T(op_data->result.var).tmp_var;
+               zval *key = &EX_T((opline+1)->result.var).tmp_var;
 
                switch (key_type) {
                        case HASH_KEY_IS_STRING:
@@ -3866,19 +4138,21 @@ ZEND_VM_HANDLER(78, ZEND_FE_FETCH, VAR, ANY)
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(114, ZEND_ISSET_ISEMPTY_VAR, CONST|TMP|VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval **value;
        zend_bool isset = 1;
 
+       SAVE_OPLINE();
        if (OP1_TYPE == IS_CV && (opline->extended_value & ZEND_QUICK_SET)) {
-               if (EX(CVs)[opline->op1.var]) {
-                       value = EX(CVs)[opline->op1.var];
+               if (EX_CV(opline->op1.var)) {
+                       value = EX_CV(opline->op1.var);
                } else if (EG(active_symbol_table)) {
                        zend_compiled_variable *cv = &CV_DEF_OF(opline->op1.var);
 
@@ -3894,7 +4168,7 @@ ZEND_VM_HANDLER(114, ZEND_ISSET_ISEMPTY_VAR, CONST|TMP|VAR|CV, ANY)
                zval tmp, *varname = GET_OP1_ZVAL_PTR(BP_VAR_IS);
 
                if (OP1_TYPE != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-                       tmp = *varname;
+                       ZVAL_COPY_VALUE(&tmp, varname);
                        zval_copy_ctor(&tmp);
                        convert_to_string(&tmp);
                        varname = &tmp;
@@ -3912,41 +4186,43 @@ ZEND_VM_HANDLER(114, ZEND_ISSET_ISEMPTY_VAR, CONST|TMP|VAR|CV, ANY)
                        }
                }
 
-               if (varname == &tmp) {
+               if (OP1_TYPE != IS_CONST && varname == &tmp) {
                        zval_dtor(&tmp);
                }
                FREE_OP1();
        }
 
-       Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
-
        if (opline->extended_value & ZEND_ISSET) {
-               if (isset && Z_TYPE_PP(value) == IS_NULL) {
-                       Z_LVAL(EX_T(opline->result.var).tmp_var) = 0;
+               if (isset && Z_TYPE_PP(value) != IS_NULL) {
+                       ZVAL_BOOL(&EX_T(opline->result.var).tmp_var, 1);
                } else {
-                       Z_LVAL(EX_T(opline->result.var).tmp_var) = isset;
+                       ZVAL_BOOL(&EX_T(opline->result.var).tmp_var, 0);
                }
        } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
                if (!isset || !i_zend_is_true(*value)) {
-                       Z_LVAL(EX_T(opline->result.var).tmp_var) = 1;
+                       ZVAL_BOOL(&EX_T(opline->result.var).tmp_var, 1);
                } else {
-                       Z_LVAL(EX_T(opline->result.var).tmp_var) = 0;
+                       ZVAL_BOOL(&EX_T(opline->result.var).tmp_var, 0);
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HELPER_EX(zend_isset_isempty_dim_prop_obj_handler, VAR|UNUSED|CV, CONST|TMP|VAR|CV, int prop_dim)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **container = GET_OP1_OBJ_ZVAL_PTR_PTR(BP_VAR_IS);
+       zval **container;
        zval **value = NULL;
        int result = 0;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = GET_OP1_OBJ_ZVAL_PTR_PTR(BP_VAR_IS);
+       
        if (OP1_TYPE != IS_VAR || container) {
                zend_free_op free_op2;
                zval *offset = GET_OP2_ZVAL_PTR(BP_VAR_R);
@@ -4040,7 +4316,7 @@ ZEND_VM_C_LABEL(num_index_prop):
                        zval tmp;
 
                        if (Z_TYPE_P(offset) != IS_LONG) {
-                               tmp = *offset;
+                               ZVAL_COPY_VALUE(&tmp, offset);
                                zval_copy_ctor(&tmp);
                                convert_to_long(&tmp);
                                offset = &tmp;
@@ -4063,15 +4339,15 @@ ZEND_VM_C_LABEL(num_index_prop):
        }
 
        Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
-
        if (opline->extended_value & ZEND_ISSET) {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = result;
-       } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+       } else {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = !result;
        }
 
        FREE_OP1_VAR_PTR();
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -4088,7 +4364,9 @@ ZEND_VM_HANDLER(148, ZEND_ISSET_ISEMPTY_PROP_OBJ, VAR|UNUSED|CV, CONST|TMP|VAR|C
 ZEND_VM_HANDLER(79, ZEND_EXIT, CONST|TMP|VAR|UNUSED|CV, ANY)
 {
 #if !defined(ZEND_VM_SPEC) || (OP1_TYPE != IS_UNUSED)
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       SAVE_OPLINE();
        if (OP1_TYPE != IS_UNUSED) {
                zend_free_op free_op1;
                zval *ptr = GET_OP1_ZVAL_PTR(BP_VAR_R);
@@ -4102,13 +4380,14 @@ ZEND_VM_HANDLER(79, ZEND_EXIT, CONST|TMP|VAR|UNUSED|CV, ANY)
        }
 #endif
        zend_bailout();
-       ZEND_VM_NEXT_OPCODE();
+       ZEND_VM_NEXT_OPCODE(); /* Never reached */
 }
 
 ZEND_VM_HANDLER(57, ZEND_BEGIN_SILENCE, ANY, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
+       SAVE_OPLINE();
        Z_LVAL(EX_T(opline->result.var).tmp_var) = EG(error_reporting);
        Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_LONG;  /* shouldn't be necessary */
        if (EX(old_error_reporting) == NULL) {
@@ -4118,20 +4397,23 @@ ZEND_VM_HANDLER(57, ZEND_BEGIN_SILENCE, ANY, ANY)
        if (EG(error_reporting)) {
                zend_alter_ini_entry_ex("error_reporting", sizeof("error_reporting"), "0", 1, ZEND_INI_USER, ZEND_INI_STAGE_RUNTIME, 1 TSRMLS_CC);
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(142, ZEND_RAISE_ABSTRACT_ERROR, ANY, ANY)
 {
+       SAVE_OPLINE();
        zend_error_noreturn(E_ERROR, "Cannot call abstract method %s::%s()", EG(scope)->name, EX(op_array)->function_name);
        ZEND_VM_NEXT_OPCODE(); /* Never reached */
 }
 
 ZEND_VM_HANDLER(58, ZEND_END_SILENCE, TMP, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval restored_error_reporting;
 
+       SAVE_OPLINE();
        if (!EG(error_reporting) && Z_LVAL(EX_T(opline->op1.var).tmp_var) != 0) {
                Z_TYPE(restored_error_reporting) = IS_LONG;
                Z_LVAL(restored_error_reporting) = Z_LVAL(EX_T(opline->op1.var).tmp_var);
@@ -4142,17 +4424,21 @@ ZEND_VM_HANDLER(58, ZEND_END_SILENCE, TMP, ANY)
        if (EX(old_error_reporting) == &EX_T(opline->op1.var).tmp_var) {
                EX(old_error_reporting) = NULL;
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(152, ZEND_JMP_SET, CONST|TMP|VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *value = GET_OP1_ZVAL_PTR(BP_VAR_R);
+       zval *value;
+
+       SAVE_OPLINE();
+       value = GET_OP1_ZVAL_PTR(BP_VAR_R);
 
        if (i_zend_is_true(value)) {
-               EX_T(opline->result.var).tmp_var = *value;
+               ZVAL_COPY_VALUE(&EX_T(opline->result.var).tmp_var, value);
                zendi_zval_copy_ctor(EX_T(opline->result.var).tmp_var);
                FREE_OP1();
 #if DEBUG_ZEND>=2
@@ -4162,102 +4448,132 @@ ZEND_VM_HANDLER(152, ZEND_JMP_SET, CONST|TMP|VAR|CV, ANY)
        }
 
        FREE_OP1();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(22, ZEND_QM_ASSIGN, CONST|TMP|VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *value = GET_OP1_ZVAL_PTR(BP_VAR_R);
+       zval *value;
 
-       EX_T(opline->result.var).tmp_var = *value;
+       SAVE_OPLINE();
+       value = GET_OP1_ZVAL_PTR(BP_VAR_R);
+
+       ZVAL_COPY_VALUE(&EX_T(opline->result.var).tmp_var, value);
        if (!IS_OP1_TMP_FREE()) {
                zval_copy_ctor(&EX_T(opline->result.var).tmp_var);
        }
        FREE_OP1_IF_VAR();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(101, ZEND_EXT_STMT, ANY, ANY)
 {
+       USE_OPLINE
+
+       SAVE_OPLINE();
        if (!EG(no_extensions)) {
                zend_llist_apply_with_argument(&zend_extensions, (llist_apply_with_arg_func_t) zend_extension_statement_handler, EX(op_array) TSRMLS_CC);
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(102, ZEND_EXT_FCALL_BEGIN, ANY, ANY)
 {
+       USE_OPLINE
+
+       SAVE_OPLINE();
        if (!EG(no_extensions)) {
                zend_llist_apply_with_argument(&zend_extensions, (llist_apply_with_arg_func_t) zend_extension_fcall_begin_handler, EX(op_array) TSRMLS_CC);
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(103, ZEND_EXT_FCALL_END, ANY, ANY)
 {
+       SAVE_OPLINE();
        if (!EG(no_extensions)) {
                zend_llist_apply_with_argument(&zend_extensions, (llist_apply_with_arg_func_t) zend_extension_fcall_end_handler, EX(op_array) TSRMLS_CC);
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(139, ZEND_DECLARE_CLASS, ANY, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
+       SAVE_OPLINE();
        EX_T(opline->result.var).class_entry = do_bind_class(EX(op_array), opline, EG(class_table), 0 TSRMLS_CC);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(140, ZEND_DECLARE_INHERITED_CLASS, ANY, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
+       SAVE_OPLINE();
        EX_T(opline->result.var).class_entry = do_bind_inherited_class(EX(op_array), opline, EG(class_table), EX_T(opline->extended_value).class_entry, 0 TSRMLS_CC);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(145, ZEND_DECLARE_INHERITED_CLASS_DELAYED, ANY, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_class_entry **pce, **pce_orig;
 
+       SAVE_OPLINE();
        if (zend_hash_quick_find(EG(class_table), Z_STRVAL_P(opline->op2.zv), Z_STRLEN_P(opline->op2.zv)+1, Z_HASH_P(opline->op2.zv), (void**)&pce) == FAILURE ||
            (zend_hash_quick_find(EG(class_table), Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), Z_HASH_P(opline->op1.zv), (void**)&pce_orig) == SUCCESS &&
             *pce != *pce_orig)) {
                do_bind_inherited_class(EX(op_array), opline, EG(class_table), EX_T(opline->extended_value).class_entry, 0 TSRMLS_CC);
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(141, ZEND_DECLARE_FUNCTION, ANY, ANY)
 {
-       do_bind_function(EX(op_array), EX(opline), EG(function_table), 0);
+       USE_OPLINE
+
+       SAVE_OPLINE();
+       do_bind_function(EX(op_array), opline, EG(function_table), 0);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(105, ZEND_TICKS, ANY, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
+       SAVE_OPLINE();
        if (++EG(ticks_count)>=opline->extended_value) {
                EG(ticks_count)=0;
                if (zend_ticks_function) {
                        zend_ticks_function(opline->extended_value);
                }
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(138, ZEND_INSTANCEOF, TMP|VAR|CV, ANY)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *expr = GET_OP1_ZVAL_PTR(BP_VAR_R);
+       zval *expr;
        zend_bool result;
 
+       SAVE_OPLINE();
+       expr = GET_OP1_ZVAL_PTR(BP_VAR_R);
+       
        if (Z_TYPE_P(expr) == IS_OBJECT && Z_OBJ_HT_P(expr)->get_class_entry) {
                result = instanceof_function(Z_OBJCE_P(expr), EX_T(opline->op2.var).class_entry TSRMLS_CC);
        } else {
@@ -4265,6 +4581,7 @@ ZEND_VM_HANDLER(138, ZEND_INSTANCEOF, TMP|VAR|CV, ANY)
        }
        ZVAL_BOOL(&EX_T(opline->result.var).tmp_var, result);
        FREE_OP1();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -4280,17 +4597,21 @@ ZEND_VM_HANDLER(0, ZEND_NOP, ANY, ANY)
 
 ZEND_VM_HANDLER(144, ZEND_ADD_INTERFACE, ANY, CONST)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_class_entry *ce = EX_T(opline->op1.var).class_entry;
-       zend_class_entry *iface = zend_fetch_class_by_name(Z_STRVAL_P(opline->op2.zv), Z_STRLEN_P(opline->op2.zv), opline->op2.literal + 1, opline->extended_value TSRMLS_CC);
+       zend_class_entry *iface;
+
+       SAVE_OPLINE();
+       iface = zend_fetch_class_by_name(Z_STRVAL_P(opline->op2.zv), Z_STRLEN_P(opline->op2.zv), opline->op2.literal + 1, opline->extended_value TSRMLS_CC);
 
        if (iface) {
-               if (!(iface->ce_flags & ZEND_ACC_INTERFACE)) {
+               if (UNEXPECTED((iface->ce_flags & ZEND_ACC_INTERFACE) == 0)) {
                        zend_error_noreturn(E_ERROR, "%s cannot implement %s - it is not an interface", ce->name, iface->name);
                }
                zend_do_implement_interface(ce, iface TSRMLS_CC);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -4298,11 +4619,11 @@ ZEND_VM_HANDLER(149, ZEND_HANDLE_EXCEPTION, ANY, ANY)
 {
        zend_uint op_num = EG(opline_before_exception)-EG(active_op_array)->opcodes;
        int i;
-       zend_uint catch_op_num;
+       zend_uint catch_op_num = 0;
        int catched = 0;
        zval restored_error_reporting;
  
-       void **stack_frame = (void**)(((char*)EX(Ts)) +
+       void **stack_frame = (void**)(((char*)EX_Ts()) +
                (ZEND_MM_ALIGNED_SIZE(sizeof(temp_variable)) * EX(op_array)->T));
 
        while (zend_vm_stack_top(TSRMLS_C) != stack_frame) {
@@ -4386,13 +4707,22 @@ ZEND_VM_HANDLER(149, ZEND_HANDLE_EXCEPTION, ANY, ANY)
 
 ZEND_VM_HANDLER(146, ZEND_VERIFY_ABSTRACT_CLASS, ANY, ANY)
 {
-       zend_verify_abstract_class(EX_T(EX(opline)->op1.var).class_entry TSRMLS_CC);
+       USE_OPLINE
+
+       SAVE_OPLINE();
+       zend_verify_abstract_class(EX_T(opline->op1.var).class_entry TSRMLS_CC);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(150, ZEND_USER_OPCODE, ANY, ANY)
 {
-       int ret = zend_user_opcode_handlers[EX(opline)->opcode](ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_INTERNAL);
+       USE_OPLINE
+       int ret;
+       
+       SAVE_OPLINE();
+       ret = zend_user_opcode_handlers[opline->opcode](ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_INTERNAL);
+       LOAD_OPLINE();
 
        switch (ret) {
                case ZEND_USER_OPCODE_CONTINUE:
@@ -4404,24 +4734,29 @@ ZEND_VM_HANDLER(150, ZEND_USER_OPCODE, ANY, ANY)
                case ZEND_USER_OPCODE_LEAVE:
                        ZEND_VM_LEAVE();
                case ZEND_USER_OPCODE_DISPATCH:
-                       ZEND_VM_DISPATCH(EX(opline)->opcode, EX(opline));
+                       ZEND_VM_DISPATCH(opline->opcode, opline);
                default:
-                       ZEND_VM_DISPATCH((zend_uchar)(ret & 0xff), EX(opline));
+                       ZEND_VM_DISPATCH((zend_uchar)(ret & 0xff), opline);
        }
 }
 
 ZEND_VM_HANDLER(143, ZEND_DECLARE_CONST, CONST, CONST)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *name  = GET_OP1_ZVAL_PTR(BP_VAR_R);
-       zval *val   = GET_OP2_ZVAL_PTR(BP_VAR_R);
+       zval *name;
+       zval *val;
        zend_constant c;
 
+       SAVE_OPLINE();
+       name  = GET_OP1_ZVAL_PTR(BP_VAR_R);
+       val   = GET_OP2_ZVAL_PTR(BP_VAR_R);
+
        if ((Z_TYPE_P(val) & IS_CONSTANT_TYPE_MASK) == IS_CONSTANT || Z_TYPE_P(val) == IS_CONSTANT_ARRAY) {
-               zval tmp = *val;
+               zval tmp;
                zval *tmp_ptr = &tmp;
 
+               ZVAL_COPY_VALUE(&tmp, val);
                if (Z_TYPE_P(val) == IS_CONSTANT_ARRAY) {
                        zval_copy_ctor(&tmp);
                }
@@ -4429,7 +4764,7 @@ ZEND_VM_HANDLER(143, ZEND_DECLARE_CONST, CONST, CONST)
                zval_update_constant(&tmp_ptr, NULL TSRMLS_CC);
                c.value = *tmp_ptr;
        } else {
-               c.value = *val;
+               INIT_PZVAL_COPY(&c.value, val);
                zval_copy_ctor(&c.value);
        }
        c.flags = CONST_CS; /* non persistent, case sensetive */
@@ -4442,21 +4777,25 @@ ZEND_VM_HANDLER(143, ZEND_DECLARE_CONST, CONST, CONST)
 
        FREE_OP1();
        FREE_OP2();
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 ZEND_VM_HANDLER(153, ZEND_DECLARE_LAMBDA_FUNCTION, CONST, UNUSED)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_function *op_array;
 
-       if (zend_hash_quick_find(EG(function_table), Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), Z_HASH_P(opline->op1.zv), (void *) &op_array) == FAILURE ||
-           op_array->type != ZEND_USER_FUNCTION) {
+       SAVE_OPLINE();
+
+       if (UNEXPECTED(zend_hash_quick_find(EG(function_table), Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), Z_HASH_P(opline->op1.zv), (void *) &op_array) == FAILURE) ||
+           UNEXPECTED(op_array->type != ZEND_USER_FUNCTION)) {
                zend_error_noreturn(E_ERROR, "Base lambda function for closure not found");
        }
 
        zend_create_closure(&EX_T(opline->result.var).tmp_var, op_array, EG(scope), EG(This) TSRMLS_CC);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
index 3650dfac24f9293e6d62001eb2c93b0785e6fbb3..aa93d4d9504022db3ddb2a70a9e872fa2f0cf942 100644 (file)
@@ -25,19 +25,46 @@ static zend_uchar zend_user_opcodes[256] = {0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,1
 static opcode_handler_t zend_vm_get_opcode_handler(zend_uchar opcode, zend_op* op);
 
 
-#define ZEND_VM_CONTINUE()   return 0
-#define ZEND_VM_RETURN()     return 1
-#define ZEND_VM_ENTER()      return 2
-#define ZEND_VM_LEAVE()      return 3
+#undef OPLINE
+#undef DCL_OPLINE
+#undef USE_OPLINE
+#undef LOAD_OPLINE
+#undef SAVE_OPLINE
+#define OPLINE EX(opline)
+#define DCL_OPLINE
+#define USE_OPLINE zend_op *opline = EX(opline);
+#define LOAD_OPLINE()
+#define SAVE_OPLINE()
+#undef CHECK_EXCEPTION
+#undef HANDLE_EXCEPTION
+#undef HANDLE_EXCEPTION_LEAVE
+#define CHECK_EXCEPTION() LOAD_OPLINE()
+#define HANDLE_EXCEPTION() LOAD_OPLINE(); ZEND_VM_CONTINUE()
+#define HANDLE_EXCEPTION_LEAVE() LOAD_OPLINE(); ZEND_VM_LEAVE()
+#define LOAD_REGS()
+#define ZEND_VM_CONTINUE()         return 0
+#define ZEND_VM_RETURN()           return 1
+#define ZEND_VM_ENTER()            return 2
+#define ZEND_VM_LEAVE()            return 3
 #define ZEND_VM_DISPATCH(opcode, opline) return zend_vm_get_opcode_handler(opcode, opline)(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 
 #define ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_INTERNAL execute_data TSRMLS_CC
 #undef EX
 #define EX(element) execute_data->element
 
+#undef EX_CV
+#define EX_CV(var) EX(CVs)[var]
+#undef EX_CVs
+#define EX_CVs() EX(CVs)
+#undef EX_T
+#define EX_T(offset) (*(temp_variable *)((char *) EX(Ts) + offset))
+#undef EX_Ts
+#define EX_Ts() EX(Ts)
+
 
 ZEND_API void execute(zend_op_array *op_array TSRMLS_DC)
 {
+       DCL_OPLINE
        zend_execute_data *execute_data;
        zend_bool nested = 0;
        zend_bool original_in_execution = EG(in_execution);
@@ -70,29 +97,27 @@ zend_vm_enter:
        EX(nested) = nested;
        nested = 1;
 
-       if (op_array->start_op) {
-               ZEND_VM_SET_OPCODE(op_array->start_op);
-       } else {
-               ZEND_VM_SET_OPCODE(op_array->opcodes);
-       }
+       LOAD_REGS();
 
        if (op_array->this_var != -1 && EG(This)) {
                Z_ADDREF_P(EG(This)); /* For $this pointer */
                if (!EG(active_symbol_table)) {
-                       EX(CVs)[op_array->this_var] = (zval**)EX(CVs) + (op_array->last_var + op_array->this_var);
-                       *EX(CVs)[op_array->this_var] = EG(This);
+                       EX_CV(op_array->this_var) = (zval**)EX_CVs() + (op_array->last_var + op_array->this_var);
+                       *EX_CV(op_array->this_var) = EG(This);
                } else {
-                       if (zend_hash_add(EG(active_symbol_table), "this", sizeof("this"), &EG(This), sizeof(zval *), (void**)&EX(CVs)[op_array->this_var])==FAILURE) {
+                       if (zend_hash_add(EG(active_symbol_table), "this", sizeof("this"), &EG(This), sizeof(zval *), (void**)&EX_CV(op_array->this_var))==FAILURE) {
                                Z_DELREF_P(EG(This));
                        }
                }
        }
 
+       EX(opline) = op_array->start_op ? op_array->start_op : op_array->opcodes;
        EG(opline_ptr) = &EX(opline);
+       LOAD_OPLINE();
 
        EX(function_state).function = (zend_function *) op_array;
        EX(function_state).arguments = NULL;
-       
+
        while (1) {
        int ret;
 #ifdef ZEND_WIN32
@@ -101,7 +126,7 @@ zend_vm_enter:
                }
 #endif
 
-               if ((ret = EX(opline)->handler(execute_data TSRMLS_CC)) > 0) {
+               if ((ret = OPLINE->handler(execute_data TSRMLS_CC)) > 0) {
                        switch (ret) {
                                case 1:
                                        EG(in_execution) = original_in_execution;
@@ -122,23 +147,28 @@ zend_vm_enter:
 
 static int ZEND_FASTCALL  ZEND_JMP_SPEC_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
+       USE_OPLINE
+
 #if DEBUG_ZEND>=2
-       printf("Jumping to %d\n", EX(opline)->op1.opline_num);
+       printf("Jumping to %d\n", opline->op1.opline_num);
 #endif
-       ZEND_VM_SET_OPCODE(EX(opline)->op1.jmp_addr);
+       ZEND_VM_SET_OPCODE(opline->op1.jmp_addr);
        ZEND_VM_CONTINUE(); /* CHECK_ME */
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_STRING_SPEC_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zval *tmp = &EX_T(EX(opline)->result.var).tmp_var;
+       USE_OPLINE
+       zval *tmp = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        tmp->value.str.val = emalloc(1);
        tmp->value.str.val[0] = 0;
        tmp->value.str.len = 0;
        Z_SET_REFCOUNT_P(tmp, 1);
        tmp->type = IS_STRING;
        Z_UNSET_ISREF_P(tmp);
+       /*CHECK_EXCEPTION();*/
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -150,8 +180,8 @@ static int ZEND_FASTCALL zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS)
        EG(current_execute_data) = EX(prev_execute_data);
        EG(opline_ptr) = NULL;
        if (!EG(active_symbol_table)) {
-               zval ***cv = EX(CVs);
-               zval ***end = cv + EX(op_array)->last_var;
+               zval ***cv = EX_CVs();
+               zval ***end = cv + op_array->last_var;
                while (cv != end) {
                        if (*cv) {
                                zval_ptr_dtor(*cv);
@@ -166,32 +196,38 @@ static int ZEND_FASTCALL zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS)
 
        if (nested) {
                execute_data = EG(current_execute_data);
+       }
+       if (nested) {
+               USE_OPLINE
 
-               if (EX(call_opline)->opcode == ZEND_INCLUDE_OR_EVAL) {
+               LOAD_REGS();
+               LOAD_OPLINE();
+               if (UNEXPECTED(opline->opcode == ZEND_INCLUDE_OR_EVAL)) {
 
                        EX(function_state).function = (zend_function *) EX(op_array);
                        EX(function_state).arguments = NULL;
                        EX(object) = EX(current_object);
 
-                       if (RETURN_VALUE_USED(EX(call_opline))) {
-                               if (!EX_T(EX(call_opline)->result.var).var.ptr) { /* there was no return statement */
-                                       ALLOC_ZVAL(EX_T(EX(call_opline)->result.var).var.ptr);
-                                       INIT_PZVAL(EX_T(EX(call_opline)->result.var).var.ptr);
-                                       Z_LVAL_P(EX_T(EX(call_opline)->result.var).var.ptr) = 1;
-                                       Z_TYPE_P(EX_T(EX(call_opline)->result.var).var.ptr) = IS_BOOL;
-                               }
-                       }
-
                        EG(opline_ptr) = &EX(opline);
                        EG(active_op_array) = EX(op_array);
                        EG(return_value_ptr_ptr) = EX(original_return_value);
                        destroy_op_array(op_array TSRMLS_CC);
                        efree(op_array);
-                       if (EG(exception)) {
+                       if (UNEXPECTED(EG(exception) != NULL)) {
                                zend_throw_exception_internal(NULL TSRMLS_CC);
+                               HANDLE_EXCEPTION_LEAVE();
+                       } else if (RETURN_VALUE_USED(opline)) {
+                               if (!EX_T(opline->result.var).var.ptr) { /* there was no return statement */
+                                       zval *retval;
+
+                                       ALLOC_ZVAL(retval);
+                                       ZVAL_BOOL(retval, 1);
+                                       INIT_PZVAL(retval);
+                                       EX_T(opline->result.var).var.ptr = retval;
+                               }
                        }
 
-                       EX(opline)++;
+                       ZEND_VM_INC_OPCODE();
                        ZEND_VM_LEAVE();
                } else {
 
@@ -215,7 +251,7 @@ static int ZEND_FASTCALL zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS)
                        EX(function_state).arguments = NULL;
 
                        if (EG(This)) {
-                               if (EG(exception) && IS_CTOR_CALL(EX(called_scope))) {
+                               if (UNEXPECTED(EG(exception) != NULL) && IS_CTOR_CALL(EX(called_scope))) {
                                        if (IS_CTOR_USED(EX(called_scope))) {
                                                Z_DELREF_P(EG(This));
                                        }
@@ -234,14 +270,15 @@ static int ZEND_FASTCALL zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS)
 
                        zend_vm_stack_clear_multiple(TSRMLS_C);
 
-                       if (EG(exception)) {
+                       if (UNEXPECTED(EG(exception) != NULL)) {
                                zend_throw_exception_internal(NULL TSRMLS_CC);
-                               if (RETURN_VALUE_USED(EX(call_opline)) && EX_T(EX(call_opline)->result.var).var.ptr) {
-                                       zval_ptr_dtor(&EX_T(EX(call_opline)->result.var).var.ptr);
+                               if (RETURN_VALUE_USED(opline) && EX_T(opline->result.var).var.ptr) {
+                                       zval_ptr_dtor(&EX_T(opline->result.var).var.ptr);
                                }
+                               HANDLE_EXCEPTION_LEAVE();
                        }
 
-                       EX(opline)++;
+                       ZEND_VM_INC_OPCODE();
                        ZEND_VM_LEAVE();
                }
        }
@@ -250,89 +287,99 @@ static int ZEND_FASTCALL zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS)
 
 static int ZEND_FASTCALL zend_do_fcall_common_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_bool should_change_scope = 0;
+       zend_function *fbc = EX(function_state).function;
 
-       if (EX(function_state).function->common.fn_flags & (ZEND_ACC_ABSTRACT|ZEND_ACC_DEPRECATED)) {
-               if (EX(function_state).function->common.fn_flags & ZEND_ACC_ABSTRACT) {
-                       zend_error_noreturn(E_ERROR, "Cannot call abstract method %s::%s()", EX(function_state).function->common.scope->name, EX(function_state).function->common.function_name);
+       SAVE_OPLINE();
+       if (UNEXPECTED((fbc->common.fn_flags & (ZEND_ACC_ABSTRACT|ZEND_ACC_DEPRECATED)) != 0)) {
+               if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_ABSTRACT) != 0)) {
+                       zend_error_noreturn(E_ERROR, "Cannot call abstract method %s::%s()", fbc->common.scope->name, fbc->common.function_name);
+                       CHECK_EXCEPTION();
                        ZEND_VM_NEXT_OPCODE(); /* Never reached */
                }
-               if (EX(function_state).function->common.fn_flags & ZEND_ACC_DEPRECATED) {
+               if (UNEXPECTED((fbc->common.fn_flags & ZEND_ACC_DEPRECATED) != 0)) {
                        zend_error(E_DEPRECATED, "Function %s%s%s() is deprecated",
-                               EX(function_state).function->common.scope ? EX(function_state).function->common.scope->name : "",
-                               EX(function_state).function->common.scope ? "::" : "",
-                               EX(function_state).function->common.function_name);
+                               fbc->common.scope ? fbc->common.scope->name : "",
+                               fbc->common.scope ? "::" : "",
+                               fbc->common.function_name);
                }
        }
-       if (EX(function_state).function->common.scope &&
-               !(EX(function_state).function->common.fn_flags & ZEND_ACC_STATIC) &&
+       if (fbc->common.scope &&
+               !(fbc->common.fn_flags & ZEND_ACC_STATIC) &&
                !EX(object)) {
 
-               if (EX(function_state).function->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
+               if (fbc->common.fn_flags & ZEND_ACC_ALLOW_STATIC) {
                        /* FIXME: output identifiers properly */
-                       zend_error(E_STRICT, "Non-static method %s::%s() should not be called statically", EX(function_state).function->common.scope->name, EX(function_state).function->common.function_name);
+                       zend_error(E_STRICT, "Non-static method %s::%s() should not be called statically", fbc->common.scope->name, fbc->common.function_name);
                } else {
                        /* FIXME: output identifiers properly */
                        /* An internal function assumes $this is present and won't check that. So PHP would crash by allowing the call. */
-                       zend_error_noreturn(E_ERROR, "Non-static method %s::%s() cannot be called statically", EX(function_state).function->common.scope->name, EX(function_state).function->common.function_name);
+                       zend_error_noreturn(E_ERROR, "Non-static method %s::%s() cannot be called statically", fbc->common.scope->name, fbc->common.function_name);
                }
        }
 
-       if (EX(function_state).function->type == ZEND_USER_FUNCTION ||
-           EX(function_state).function->common.scope) {
+       if (fbc->type == ZEND_USER_FUNCTION || fbc->common.scope) {
                should_change_scope = 1;
                EX(current_this) = EG(This);
                EX(current_scope) = EG(scope);
                EX(current_called_scope) = EG(called_scope);
                EG(This) = EX(object);
-               EG(scope) = (EX(function_state).function->type == ZEND_USER_FUNCTION || !EX(object)) ? EX(function_state).function->common.scope : NULL;
+               EG(scope) = (fbc->type == ZEND_USER_FUNCTION || !EX(object)) ? fbc->common.scope : NULL;
                EG(called_scope) = EX(called_scope);
        }
 
        zend_arg_types_stack_3_pop(&EG(arg_types_stack), &EX(called_scope), &EX(current_object), &EX(fbc));
        EX(function_state).arguments = zend_vm_stack_push_args(opline->extended_value TSRMLS_CC);
+       LOAD_OPLINE();
+
+       if (fbc->type == ZEND_INTERNAL_FUNCTION) {
+               temp_variable *ret = &EX_T(opline->result.var);
 
-       if (EX(function_state).function->type == ZEND_INTERNAL_FUNCTION) {
-               ALLOC_INIT_ZVAL(EX_T(opline->result.var).var.ptr);
-               EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-               EX_T(opline->result.var).var.fcall_returned_reference = EX(function_state).function->common.return_reference;
+               MAKE_STD_ZVAL(ret->var.ptr);
+               ZVAL_NULL(ret->var.ptr);
+               ret->var.ptr_ptr = &ret->var.ptr;
+               ret->var.fcall_returned_reference = fbc->common.return_reference;
 
-               if (EX(function_state).function->common.arg_info) {
+               if (fbc->common.arg_info) {
                        zend_uint i=0;
                        zval **p = (zval**)EX(function_state).arguments;
                        ulong arg_count = opline->extended_value;
 
                        while (arg_count>0) {
-                               zend_verify_arg_type(EX(function_state).function, ++i, *(p-arg_count), 0 TSRMLS_CC);
+                               zend_verify_arg_type(fbc, ++i, *(p-arg_count), 0 TSRMLS_CC);
                                arg_count--;
                        }
                }
+
                if (!zend_execute_internal) {
                        /* saves one function call if zend_execute_internal is not used */
-                       ((zend_internal_function *) EX(function_state).function)->handler(opline->extended_value, EX_T(opline->result.var).var.ptr, EX(function_state).function->common.return_reference?&EX_T(opline->result.var).var.ptr:NULL, EX(object), RETURN_VALUE_USED(opline) TSRMLS_CC);
+                       fbc->internal_function.handler(opline->extended_value, ret->var.ptr, fbc->common.return_reference ? &ret->var.ptr : NULL, EX(object), RETURN_VALUE_USED(opline) TSRMLS_CC);
                } else {
                        zend_execute_internal(execute_data, RETURN_VALUE_USED(opline) TSRMLS_CC);
                }
 
                if (!RETURN_VALUE_USED(opline)) {
-                       zval_ptr_dtor(&EX_T(opline->result.var).var.ptr);
+                       zval_ptr_dtor(&ret->var.ptr);
                }
-       } else if (EX(function_state).function->type == ZEND_USER_FUNCTION) {
+       } else if (fbc->type == ZEND_USER_FUNCTION) {
                EX(original_return_value) = EG(return_value_ptr_ptr);
                EG(active_symbol_table) = NULL;
-               EG(active_op_array) = &EX(function_state).function->op_array;
+               EG(active_op_array) = &fbc->op_array;
                EG(return_value_ptr_ptr) = NULL;
                if (RETURN_VALUE_USED(opline)) {
-                       EG(return_value_ptr_ptr) = &EX_T(opline->result.var).var.ptr;
-                       EX_T(opline->result.var).var.ptr = NULL;
-                       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-                       EX_T(opline->result.var).var.fcall_returned_reference = EX(function_state).function->common.return_reference;
+                       temp_variable *ret = &EX_T(opline->result.var);
+
+                       ret->var.ptr = NULL;
+                       EG(return_value_ptr_ptr) = &ret->var.ptr;
+                       ret->var.ptr_ptr = &ret->var.ptr;
+                       ret->var.fcall_returned_reference = fbc->common.return_reference;
                }
 
-               if (zend_execute == execute && !EG(exception)) {
-                       EX(call_opline) = opline;
-                       ZEND_VM_ENTER();
+               if (EXPECTED(zend_execute == execute)) {
+                       if (EXPECTED(EG(exception) == NULL)) {
+                               ZEND_VM_ENTER();
+                       }
                } else {
                        zend_execute(EG(active_op_array) TSRMLS_CC);
                }
@@ -353,19 +400,20 @@ static int ZEND_FASTCALL zend_do_fcall_common_helper_SPEC(ZEND_OPCODE_HANDLER_AR
                }
                EG(active_symbol_table) = EX(symbol_table);
        } else { /* ZEND_OVERLOADED_FUNCTION */
-               ALLOC_INIT_ZVAL(EX_T(opline->result.var).var.ptr);
+               MAKE_STD_ZVAL(EX_T(opline->result.var).var.ptr);
+               ZVAL_NULL(EX_T(opline->result.var).var.ptr);
 
                        /* Not sure what should be done here if it's a static method */
-               if (EX(object)) {
-                       Z_OBJ_HT_P(EX(object))->call_method(EX(function_state).function->common.function_name, opline->extended_value, EX_T(opline->result.var).var.ptr, &EX_T(opline->result.var).var.ptr, EX(object), RETURN_VALUE_USED(opline) TSRMLS_CC);
+               if (EXPECTED(EX(object) != NULL)) {
+                       Z_OBJ_HT_P(EX(object))->call_method(fbc->common.function_name, opline->extended_value, EX_T(opline->result.var).var.ptr, &EX_T(opline->result.var).var.ptr, EX(object), RETURN_VALUE_USED(opline) TSRMLS_CC);
                } else {
                        zend_error_noreturn(E_ERROR, "Cannot call overloaded function for non-object");
                }
 
-               if (EX(function_state).function->type == ZEND_OVERLOADED_FUNCTION_TEMPORARY) {
-                       efree(EX(function_state).function->common.function_name);
+               if (fbc->type == ZEND_OVERLOADED_FUNCTION_TEMPORARY) {
+                       efree(fbc->common.function_name);
                }
-               efree(EX(function_state).function);
+               efree(fbc);
 
                if (!RETURN_VALUE_USED(opline)) {
                        zval_ptr_dtor(&EX_T(opline->result.var).var.ptr);
@@ -382,7 +430,7 @@ static int ZEND_FASTCALL zend_do_fcall_common_helper_SPEC(ZEND_OPCODE_HANDLER_AR
 
        if (should_change_scope) {
                if (EG(This)) {
-                       if (EG(exception) && IS_CTOR_CALL(EX(called_scope))) {
+                       if (UNEXPECTED(EG(exception) != NULL) && IS_CTOR_CALL(EX(called_scope))) {
                                if (IS_CTOR_USED(EX(called_scope))) {
                                        Z_DELREF_P(EG(This));
                                }
@@ -402,11 +450,12 @@ static int ZEND_FASTCALL zend_do_fcall_common_helper_SPEC(ZEND_OPCODE_HANDLER_AR
 
        zend_vm_stack_clear_multiple(TSRMLS_C);
 
-       if (EG(exception)) {
+       if (UNEXPECTED(EG(exception) != NULL)) {
                zend_throw_exception_internal(NULL TSRMLS_CC);
                if (RETURN_VALUE_USED(opline) && EX_T(opline->result.var).var.ptr) {
                        zval_ptr_dtor(&EX_T(opline->result.var).var.ptr);
                }
+               HANDLE_EXCEPTION();
        }
 
        ZEND_VM_NEXT_OPCODE();
@@ -420,46 +469,53 @@ static int ZEND_FASTCALL  ZEND_DO_FCALL_BY_NAME_SPEC_HANDLER(ZEND_OPCODE_HANDLER
 
 static int ZEND_FASTCALL  ZEND_RECV_SPEC_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_uint arg_num = opline->op1.num;
        zval **param = zend_vm_stack_get_arg(arg_num TSRMLS_CC);
 
-       if (param == NULL) {
-               char *space;
-               char *class_name = get_active_class_name(&space TSRMLS_CC);
-               zend_execute_data *ptr = EX(prev_execute_data);
-
+       SAVE_OPLINE();
+       if (UNEXPECTED(param == NULL)) {
                if (zend_verify_arg_type((zend_function *) EG(active_op_array), arg_num, NULL, opline->extended_value TSRMLS_CC)) {
+                       char *space;
+                       char *class_name;
+                       zend_execute_data *ptr;
+
+                       if (EG(active_op_array)->scope) {
+                               class_name = EG(active_op_array)->scope->name;
+                               space = "::";
+                       } else {
+                               class_name = space = "";
+                       }
+                       ptr = EX(prev_execute_data);
+
                        if(ptr && ptr->op_array) {
                                zend_error(E_WARNING, "Missing argument %u for %s%s%s(), called in %s on line %d and defined", opline->op1.num, class_name, space, get_active_function_name(TSRMLS_C), ptr->op_array->filename, ptr->opline->lineno);
                        } else {
                                zend_error(E_WARNING, "Missing argument %u for %s%s%s()", opline->op1.num, class_name, space, get_active_function_name(TSRMLS_C));
                        }
                }
-               if (opline->result_type == IS_VAR) {
-                       PZVAL_UNLOCK_FREE(*EX_T(opline->result.var).var.ptr_ptr);
-               }
        } else {
-               zend_free_op free_res;
                zval **var_ptr;
 
                zend_verify_arg_type((zend_function *) EG(active_op_array), arg_num, *param, opline->extended_value TSRMLS_CC);
-               var_ptr = get_zval_ptr_ptr(opline->result_type, &opline->result, EX(Ts), &free_res, BP_VAR_W);
+               var_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->result.var TSRMLS_CC);
                Z_DELREF_PP(var_ptr);
                *var_ptr = *param;
                Z_ADDREF_PP(var_ptr);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_NEW_SPEC_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *object_zval;
        zend_function *constructor;
 
-       if (EX_T(opline->op1.var).class_entry->ce_flags & (ZEND_ACC_INTERFACE|ZEND_ACC_IMPLICIT_ABSTRACT_CLASS|ZEND_ACC_EXPLICIT_ABSTRACT_CLASS)) {
+       SAVE_OPLINE();
+       if (UNEXPECTED((EX_T(opline->op1.var).class_entry->ce_flags & (ZEND_ACC_INTERFACE|ZEND_ACC_IMPLICIT_ABSTRACT_CLASS|ZEND_ACC_EXPLICIT_ABSTRACT_CLASS)) != 0)) {
                char *class_type;
 
                if (EX_T(opline->op1.var).class_entry->ce_flags & ZEND_ACC_INTERFACE) {
@@ -477,15 +533,15 @@ static int ZEND_FASTCALL  ZEND_NEW_SPEC_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 
        if (constructor == NULL) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, object_zval);
+                       AI_SET_PTR(&EX_T(opline->result.var), object_zval);
                } else {
                        zval_ptr_dtor(&object_zval);
                }
                ZEND_VM_JMP(EX(op_array)->opcodes + opline->op2.opline_num);
        } else {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, object_zval);
                        PZVAL_LOCK(object_zval);
+                       AI_SET_PTR(&EX_T(opline->result.var), object_zval);
                }
 
                zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), ENCODE_CTOR(EX(called_scope), RETURN_VALUE_USED(opline)));
@@ -495,14 +551,16 @@ static int ZEND_FASTCALL  ZEND_NEW_SPEC_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
                EX(fbc) = constructor;
                EX(called_scope) = EX_T(opline->op1.var).class_entry;
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 }
 
 static int ZEND_FASTCALL  ZEND_BEGIN_SILENCE_SPEC_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
+       SAVE_OPLINE();
        Z_LVAL(EX_T(opline->result.var).tmp_var) = EG(error_reporting);
        Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_LONG;  /* shouldn't be necessary */
        if (EX(old_error_reporting) == NULL) {
@@ -512,84 +570,108 @@ static int ZEND_FASTCALL  ZEND_BEGIN_SILENCE_SPEC_HANDLER(ZEND_OPCODE_HANDLER_AR
        if (EG(error_reporting)) {
                zend_alter_ini_entry_ex("error_reporting", sizeof("error_reporting"), "0", 1, ZEND_INI_USER, ZEND_INI_STAGE_RUNTIME, 1 TSRMLS_CC);
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_RAISE_ABSTRACT_ERROR_SPEC_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
+       SAVE_OPLINE();
        zend_error_noreturn(E_ERROR, "Cannot call abstract method %s::%s()", EG(scope)->name, EX(op_array)->function_name);
        ZEND_VM_NEXT_OPCODE(); /* Never reached */
 }
 
 static int ZEND_FASTCALL  ZEND_EXT_STMT_SPEC_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
+       USE_OPLINE
+
+       SAVE_OPLINE();
        if (!EG(no_extensions)) {
                zend_llist_apply_with_argument(&zend_extensions, (llist_apply_with_arg_func_t) zend_extension_statement_handler, EX(op_array) TSRMLS_CC);
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_EXT_FCALL_BEGIN_SPEC_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
+       USE_OPLINE
+
+       SAVE_OPLINE();
        if (!EG(no_extensions)) {
                zend_llist_apply_with_argument(&zend_extensions, (llist_apply_with_arg_func_t) zend_extension_fcall_begin_handler, EX(op_array) TSRMLS_CC);
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_EXT_FCALL_END_SPEC_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
+       SAVE_OPLINE();
        if (!EG(no_extensions)) {
                zend_llist_apply_with_argument(&zend_extensions, (llist_apply_with_arg_func_t) zend_extension_fcall_end_handler, EX(op_array) TSRMLS_CC);
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_DECLARE_CLASS_SPEC_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
+       SAVE_OPLINE();
        EX_T(opline->result.var).class_entry = do_bind_class(EX(op_array), opline, EG(class_table), 0 TSRMLS_CC);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_DECLARE_INHERITED_CLASS_SPEC_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
+       SAVE_OPLINE();
        EX_T(opline->result.var).class_entry = do_bind_inherited_class(EX(op_array), opline, EG(class_table), EX_T(opline->extended_value).class_entry, 0 TSRMLS_CC);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_DECLARE_INHERITED_CLASS_DELAYED_SPEC_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_class_entry **pce, **pce_orig;
 
+       SAVE_OPLINE();
        if (zend_hash_quick_find(EG(class_table), Z_STRVAL_P(opline->op2.zv), Z_STRLEN_P(opline->op2.zv)+1, Z_HASH_P(opline->op2.zv), (void**)&pce) == FAILURE ||
            (zend_hash_quick_find(EG(class_table), Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), Z_HASH_P(opline->op1.zv), (void**)&pce_orig) == SUCCESS &&
             *pce != *pce_orig)) {
                do_bind_inherited_class(EX(op_array), opline, EG(class_table), EX_T(opline->extended_value).class_entry, 0 TSRMLS_CC);
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_DECLARE_FUNCTION_SPEC_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       do_bind_function(EX(op_array), EX(opline), EG(function_table), 0);
+       USE_OPLINE
+
+       SAVE_OPLINE();
+       do_bind_function(EX(op_array), opline, EG(function_table), 0);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_TICKS_SPEC_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
+       SAVE_OPLINE();
        if (++EG(ticks_count)>=opline->extended_value) {
                EG(ticks_count)=0;
                if (zend_ticks_function) {
                        zend_ticks_function(opline->extended_value);
                }
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -607,11 +689,11 @@ static int ZEND_FASTCALL  ZEND_HANDLE_EXCEPTION_SPEC_HANDLER(ZEND_OPCODE_HANDLER
 {
        zend_uint op_num = EG(opline_before_exception)-EG(active_op_array)->opcodes;
        int i;
-       zend_uint catch_op_num;
+       zend_uint catch_op_num = 0;
        int catched = 0;
        zval restored_error_reporting;
 
-       void **stack_frame = (void**)(((char*)EX(Ts)) +
+       void **stack_frame = (void**)(((char*)EX_Ts()) +
                (ZEND_MM_ALIGNED_SIZE(sizeof(temp_variable)) * EX(op_array)->T));
 
        while (zend_vm_stack_top(TSRMLS_C) != stack_frame) {
@@ -695,13 +777,22 @@ static int ZEND_FASTCALL  ZEND_HANDLE_EXCEPTION_SPEC_HANDLER(ZEND_OPCODE_HANDLER
 
 static int ZEND_FASTCALL  ZEND_VERIFY_ABSTRACT_CLASS_SPEC_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_verify_abstract_class(EX_T(EX(opline)->op1.var).class_entry TSRMLS_CC);
+       USE_OPLINE
+
+       SAVE_OPLINE();
+       zend_verify_abstract_class(EX_T(opline->op1.var).class_entry TSRMLS_CC);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_USER_OPCODE_SPEC_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       int ret = zend_user_opcode_handlers[EX(opline)->opcode](ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_INTERNAL);
+       USE_OPLINE
+       int ret;
+
+       SAVE_OPLINE();
+       ret = zend_user_opcode_handlers[opline->opcode](ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_INTERNAL);
+       LOAD_OPLINE();
 
        switch (ret) {
                case ZEND_USER_OPCODE_CONTINUE:
@@ -713,19 +804,21 @@ static int ZEND_FASTCALL  ZEND_USER_OPCODE_SPEC_HANDLER(ZEND_OPCODE_HANDLER_ARGS
                case ZEND_USER_OPCODE_LEAVE:
                        ZEND_VM_LEAVE();
                case ZEND_USER_OPCODE_DISPATCH:
-                       ZEND_VM_DISPATCH(EX(opline)->opcode, EX(opline));
+                       ZEND_VM_DISPATCH(opline->opcode, opline);
                default:
-                       ZEND_VM_DISPATCH((zend_uchar)(ret & 0xff), EX(opline));
+                       ZEND_VM_DISPATCH((zend_uchar)(ret & 0xff), opline);
        }
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_CLASS_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-
+       USE_OPLINE
 
+       SAVE_OPLINE();
+       EG(exception) = NULL;
        if (IS_CONST == IS_UNUSED) {
                EX_T(opline->result.var).class_entry = zend_fetch_class(NULL, 0, opline->extended_value TSRMLS_CC);
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
 
@@ -741,90 +834,96 @@ static int ZEND_FASTCALL  ZEND_FETCH_CLASS_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLE
                        zend_error_noreturn(E_ERROR, "Class name must be a valid object or a string");
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_FCALL_BY_NAME_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
-       char *function_name_strval, *lcname;
-       int function_name_strlen;
-
-
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
        if (IS_CONST == IS_CONST) {
-               if (zend_hash_quick_find(EG(function_table), Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv)+1, Z_HASH_P(opline->op1.zv), (void **) &EX(fbc)) == FAILURE) {
+               function_name = opline->op1.zv;
+               if (UNEXPECTED(zend_hash_quick_find(EG(function_table), Z_STRVAL_P(function_name), Z_STRLEN_P(function_name)+1, Z_HASH_P(function_name), (void **) &EX(fbc)) == FAILURE)) {
+                       SAVE_OPLINE();
                        zend_error_noreturn(E_ERROR, "Call to undefined function %s()", Z_STRVAL_P(opline->op2.zv));
                }
+               EX(object) = NULL;
+               /*CHECK_EXCEPTION();*/
+               ZEND_VM_NEXT_OPCODE();
        } else {
+               char *function_name_strval, *lcname;
+               int function_name_strlen;
+
+
+               SAVE_OPLINE();
                function_name = opline->op2.zv;
 
-               if (IS_CONST != IS_CONST &&
-                   Z_TYPE_P(function_name) == IS_OBJECT &&
+               if (EXPECTED(Z_TYPE_P(function_name) == IS_STRING)) {
+                       function_name_strval = Z_STRVAL_P(function_name);
+                       function_name_strlen = Z_STRLEN_P(function_name);
+                       if (function_name_strval[0] == '\\') {
+                           function_name_strlen -= 1;
+                               lcname = zend_str_tolower_dup(function_name_strval + 1, function_name_strlen);
+                       } else {
+                               lcname = zend_str_tolower_dup(function_name_strval, function_name_strlen);
+                       }
+                       if (UNEXPECTED(zend_hash_find(EG(function_table), lcname, function_name_strlen+1, (void **) &EX(fbc)) == FAILURE)) {
+                               zend_error_noreturn(E_ERROR, "Call to undefined function %s()", function_name_strval);
+                       }
+                       efree(lcname);
+
+                       EX(object) = NULL;
+                       CHECK_EXCEPTION();
+                       ZEND_VM_NEXT_OPCODE();
+               } else if (IS_CONST != IS_CONST &&
+                   EXPECTED(Z_TYPE_P(function_name) == IS_OBJECT) &&
                        Z_OBJ_HANDLER_P(function_name, get_closure) &&
                        Z_OBJ_HANDLER_P(function_name, get_closure)(function_name, &EX(called_scope), &EX(fbc), &EX(object) TSRMLS_CC) == SUCCESS) {
                        if (EX(object)) {
                                Z_ADDREF_P(EX(object));
                        }
 
+                       CHECK_EXCEPTION();
                        ZEND_VM_NEXT_OPCODE();
-               }
-
-               if (Z_TYPE_P(function_name) != IS_STRING) {
-                       zend_error_noreturn(E_ERROR, "Function name must be a string");
-               }
-               function_name_strval = Z_STRVAL_P(function_name);
-               function_name_strlen = Z_STRLEN_P(function_name);
-               if (function_name_strval[0] == '\\') {
-
-                   function_name_strlen -= 1;
-                       lcname = zend_str_tolower_dup(function_name_strval + 1, function_name_strlen);
                } else {
-                       lcname = zend_str_tolower_dup(function_name_strval, function_name_strlen);
-               }
-               if (zend_hash_find(EG(function_table), lcname, function_name_strlen+1, (void **) &EX(fbc)) == FAILURE) {
-                       zend_error_noreturn(E_ERROR, "Call to undefined function %s()", function_name_strval);
+                       zend_error_noreturn(E_ERROR, "Function name must be a string");
                }
-               efree(lcname);
-
        }
-
-       EX(object) = NULL;
-       ZEND_VM_NEXT_OPCODE();
 }
 
 
 static int ZEND_FASTCALL  ZEND_INIT_NS_FCALL_BY_NAME_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline + 1;
+       USE_OPLINE
 
-       ZEND_VM_INC_OPCODE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
        if (zend_hash_quick_find(EG(function_table), Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv)+1, Z_HASH_P(opline->op1.zv), (void **) &EX(fbc))==FAILURE) {
-               char *short_name = Z_STRVAL_P(opline->op1.zv)+op_data->op1.num;
-               if (zend_hash_quick_find(EG(function_table), short_name, Z_STRLEN_P(opline->op1.zv)-op_data->op1.num+1, op_data->extended_value, (void **) &EX(fbc))==FAILURE) {
+               char *short_name = Z_STRVAL_P(opline->op1.zv) + (opline+1)->op1.num;
+               if (UNEXPECTED(zend_hash_quick_find(EG(function_table), short_name, Z_STRLEN_P(opline->op1.zv) - (opline+1)->op1.num+1, (opline+1)->extended_value, (void **) &EX(fbc))==FAILURE)) {
+                       SAVE_OPLINE();
                        zend_error_noreturn(E_ERROR, "Call to undefined function %s()", Z_STRVAL_P(opline->op2.zv));
                }
        }
 
        EX(object) = NULL;
+       ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_RECV_INIT_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *assignment_value;
        zend_uint arg_num = opline->op1.num;
-       zend_free_op free_res;
        zval **param = zend_vm_stack_get_arg(arg_num TSRMLS_CC);
        zval **var_ptr;
 
+       SAVE_OPLINE();
        if (param == NULL) {
                ALLOC_ZVAL(assignment_value);
                *assignment_value = *opline->op2.zv;
@@ -842,33 +941,36 @@ static int ZEND_FASTCALL  ZEND_RECV_INIT_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_
        }
 
        zend_verify_arg_type((zend_function *) EG(active_op_array), arg_num, assignment_value, opline->extended_value TSRMLS_CC);
-       var_ptr = get_zval_ptr_ptr(opline->result_type, &opline->result, EX(Ts), &free_res, BP_VAR_W);
+       var_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->result.var TSRMLS_CC);
        Z_DELREF_PP(var_ptr);
        *var_ptr = assignment_value;
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BRK_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zend_brk_cont_element *el;
 
+       SAVE_OPLINE();
        el = zend_brk_cont(opline->op2.zv, opline->op1.opline_num,
-                          EX(op_array), EX(Ts) TSRMLS_CC);
+                          EX(op_array), EX_Ts() TSRMLS_CC);
 
        ZEND_VM_JMP(EX(op_array)->opcodes + el->brk);
 }
 
 static int ZEND_FASTCALL  ZEND_CONT_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zend_brk_cont_element *el;
 
+       SAVE_OPLINE();
        el = zend_brk_cont(opline->op2.zv, opline->op1.opline_num,
-                          EX(op_array), EX(Ts) TSRMLS_CC);
+                          EX(op_array), EX_Ts() TSRMLS_CC);
 
        ZEND_VM_JMP(EX(op_array)->opcodes + el->cont);
 }
@@ -876,11 +978,12 @@ static int ZEND_FASTCALL  ZEND_CONT_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 static int ZEND_FASTCALL  ZEND_GOTO_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
        zend_op *brk_opline;
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_brk_cont_element *el;
 
+       SAVE_OPLINE();
        el = zend_brk_cont(opline->op2.zv, opline->extended_value,
-                          EX(op_array), EX(Ts) TSRMLS_CC);
+                          EX(op_array), EX_Ts() TSRMLS_CC);
 
        brk_opline = EX(op_array)->opcodes + el->brk;
 
@@ -901,31 +1004,37 @@ static int ZEND_FASTCALL  ZEND_GOTO_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 
 static int ZEND_FASTCALL  ZEND_ADD_INTERFACE_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_class_entry *ce = EX_T(opline->op1.var).class_entry;
-       zend_class_entry *iface = zend_fetch_class_by_name(Z_STRVAL_P(opline->op2.zv), Z_STRLEN_P(opline->op2.zv), opline->op2.literal + 1, opline->extended_value TSRMLS_CC);
+       zend_class_entry *iface;
+
+       SAVE_OPLINE();
+       iface = zend_fetch_class_by_name(Z_STRVAL_P(opline->op2.zv), Z_STRLEN_P(opline->op2.zv), opline->op2.literal + 1, opline->extended_value TSRMLS_CC);
 
        if (iface) {
-               if (!(iface->ce_flags & ZEND_ACC_INTERFACE)) {
+               if (UNEXPECTED((iface->ce_flags & ZEND_ACC_INTERFACE) == 0)) {
                        zend_error_noreturn(E_ERROR, "%s cannot implement %s - it is not an interface", ce->name, iface->name);
                }
                zend_do_implement_interface(ce, iface TSRMLS_CC);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_CLASS_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-
+       USE_OPLINE
 
+       SAVE_OPLINE();
+       EG(exception) = NULL;
        if (IS_TMP_VAR == IS_UNUSED) {
                EX_T(opline->result.var).class_entry = zend_fetch_class(NULL, 0, opline->extended_value TSRMLS_CC);
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
                zend_free_op free_op2;
-               zval *class_name = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+               zval *class_name = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
                if (IS_TMP_VAR == IS_CONST) {
                        EX_T(opline->result.var).class_entry = zend_fetch_class_by_name(Z_STRVAL_P(class_name), Z_STRLEN_P(class_name), opline->op2.literal + 1, opline->extended_value TSRMLS_CC);
@@ -938,97 +1047,107 @@ static int ZEND_FASTCALL  ZEND_FETCH_CLASS_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_
                }
 
                zval_dtor(free_op2.var);
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_FCALL_BY_NAME_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
-       char *function_name_strval, *lcname;
-       int function_name_strlen;
-       zend_free_op free_op2;
-
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
        if (IS_TMP_VAR == IS_CONST) {
-               if (zend_hash_quick_find(EG(function_table), Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv)+1, Z_HASH_P(opline->op1.zv), (void **) &EX(fbc)) == FAILURE) {
+               function_name = opline->op1.zv;
+               if (UNEXPECTED(zend_hash_quick_find(EG(function_table), Z_STRVAL_P(function_name), Z_STRLEN_P(function_name)+1, Z_HASH_P(function_name), (void **) &EX(fbc)) == FAILURE)) {
+                       SAVE_OPLINE();
                        zend_error_noreturn(E_ERROR, "Call to undefined function %s()", Z_STRVAL_P(opline->op2.zv));
                }
+               EX(object) = NULL;
+               /*CHECK_EXCEPTION();*/
+               ZEND_VM_NEXT_OPCODE();
        } else {
-               function_name = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+               char *function_name_strval, *lcname;
+               int function_name_strlen;
+               zend_free_op free_op2;
+
+               SAVE_OPLINE();
+               function_name = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
-               if (IS_TMP_VAR != IS_CONST &&
-                   Z_TYPE_P(function_name) == IS_OBJECT &&
+               if (EXPECTED(Z_TYPE_P(function_name) == IS_STRING)) {
+                       function_name_strval = Z_STRVAL_P(function_name);
+                       function_name_strlen = Z_STRLEN_P(function_name);
+                       if (function_name_strval[0] == '\\') {
+                           function_name_strlen -= 1;
+                               lcname = zend_str_tolower_dup(function_name_strval + 1, function_name_strlen);
+                       } else {
+                               lcname = zend_str_tolower_dup(function_name_strval, function_name_strlen);
+                       }
+                       if (UNEXPECTED(zend_hash_find(EG(function_table), lcname, function_name_strlen+1, (void **) &EX(fbc)) == FAILURE)) {
+                               zend_error_noreturn(E_ERROR, "Call to undefined function %s()", function_name_strval);
+                       }
+                       efree(lcname);
+                       zval_dtor(free_op2.var);
+                       EX(object) = NULL;
+                       CHECK_EXCEPTION();
+                       ZEND_VM_NEXT_OPCODE();
+               } else if (IS_TMP_VAR != IS_CONST &&
+                   EXPECTED(Z_TYPE_P(function_name) == IS_OBJECT) &&
                        Z_OBJ_HANDLER_P(function_name, get_closure) &&
                        Z_OBJ_HANDLER_P(function_name, get_closure)(function_name, &EX(called_scope), &EX(fbc), &EX(object) TSRMLS_CC) == SUCCESS) {
                        if (EX(object)) {
                                Z_ADDREF_P(EX(object));
                        }
                        zval_dtor(free_op2.var);
+                       CHECK_EXCEPTION();
                        ZEND_VM_NEXT_OPCODE();
-               }
-
-               if (Z_TYPE_P(function_name) != IS_STRING) {
-                       zend_error_noreturn(E_ERROR, "Function name must be a string");
-               }
-               function_name_strval = Z_STRVAL_P(function_name);
-               function_name_strlen = Z_STRLEN_P(function_name);
-               if (function_name_strval[0] == '\\') {
-
-                   function_name_strlen -= 1;
-                       lcname = zend_str_tolower_dup(function_name_strval + 1, function_name_strlen);
                } else {
-                       lcname = zend_str_tolower_dup(function_name_strval, function_name_strlen);
-               }
-               if (zend_hash_find(EG(function_table), lcname, function_name_strlen+1, (void **) &EX(fbc)) == FAILURE) {
-                       zend_error_noreturn(E_ERROR, "Call to undefined function %s()", function_name_strval);
+                       zend_error_noreturn(E_ERROR, "Function name must be a string");
                }
-               efree(lcname);
-               zval_dtor(free_op2.var);
        }
-
-       EX(object) = NULL;
-       ZEND_VM_NEXT_OPCODE();
 }
 
 
 static int ZEND_FASTCALL  ZEND_BRK_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zend_brk_cont_element *el;
 
-       el = zend_brk_cont(_get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC), opline->op1.opline_num,
-                          EX(op_array), EX(Ts) TSRMLS_CC);
+       SAVE_OPLINE();
+       el = zend_brk_cont(_get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), opline->op1.opline_num,
+                          EX(op_array), EX_Ts() TSRMLS_CC);
        zval_dtor(free_op2.var);
        ZEND_VM_JMP(EX(op_array)->opcodes + el->brk);
 }
 
 static int ZEND_FASTCALL  ZEND_CONT_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zend_brk_cont_element *el;
 
-       el = zend_brk_cont(_get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC), opline->op1.opline_num,
-                          EX(op_array), EX(Ts) TSRMLS_CC);
+       SAVE_OPLINE();
+       el = zend_brk_cont(_get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), opline->op1.opline_num,
+                          EX(op_array), EX_Ts() TSRMLS_CC);
        zval_dtor(free_op2.var);
        ZEND_VM_JMP(EX(op_array)->opcodes + el->cont);
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_CLASS_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-
+       USE_OPLINE
 
+       SAVE_OPLINE();
+       EG(exception) = NULL;
        if (IS_VAR == IS_UNUSED) {
                EX_T(opline->result.var).class_entry = zend_fetch_class(NULL, 0, opline->extended_value TSRMLS_CC);
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
                zend_free_op free_op2;
-               zval *class_name = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+               zval *class_name = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
                if (IS_VAR == IS_CONST) {
                        EX_T(opline->result.var).class_entry = zend_fetch_class_by_name(Z_STRVAL_P(class_name), Z_STRLEN_P(class_name), opline->op2.literal + 1, opline->extended_value TSRMLS_CC);
@@ -1041,93 +1160,103 @@ static int ZEND_FASTCALL  ZEND_FETCH_CLASS_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_
                }
 
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_FCALL_BY_NAME_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
-       char *function_name_strval, *lcname;
-       int function_name_strlen;
-       zend_free_op free_op2;
-
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
        if (IS_VAR == IS_CONST) {
-               if (zend_hash_quick_find(EG(function_table), Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv)+1, Z_HASH_P(opline->op1.zv), (void **) &EX(fbc)) == FAILURE) {
+               function_name = opline->op1.zv;
+               if (UNEXPECTED(zend_hash_quick_find(EG(function_table), Z_STRVAL_P(function_name), Z_STRLEN_P(function_name)+1, Z_HASH_P(function_name), (void **) &EX(fbc)) == FAILURE)) {
+                       SAVE_OPLINE();
                        zend_error_noreturn(E_ERROR, "Call to undefined function %s()", Z_STRVAL_P(opline->op2.zv));
                }
+               EX(object) = NULL;
+               /*CHECK_EXCEPTION();*/
+               ZEND_VM_NEXT_OPCODE();
        } else {
-               function_name = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+               char *function_name_strval, *lcname;
+               int function_name_strlen;
+               zend_free_op free_op2;
 
-               if (IS_VAR != IS_CONST &&
-                   Z_TYPE_P(function_name) == IS_OBJECT &&
+               SAVE_OPLINE();
+               function_name = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
+               if (EXPECTED(Z_TYPE_P(function_name) == IS_STRING)) {
+                       function_name_strval = Z_STRVAL_P(function_name);
+                       function_name_strlen = Z_STRLEN_P(function_name);
+                       if (function_name_strval[0] == '\\') {
+                           function_name_strlen -= 1;
+                               lcname = zend_str_tolower_dup(function_name_strval + 1, function_name_strlen);
+                       } else {
+                               lcname = zend_str_tolower_dup(function_name_strval, function_name_strlen);
+                       }
+                       if (UNEXPECTED(zend_hash_find(EG(function_table), lcname, function_name_strlen+1, (void **) &EX(fbc)) == FAILURE)) {
+                               zend_error_noreturn(E_ERROR, "Call to undefined function %s()", function_name_strval);
+                       }
+                       efree(lcname);
+                       if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+                       EX(object) = NULL;
+                       CHECK_EXCEPTION();
+                       ZEND_VM_NEXT_OPCODE();
+               } else if (IS_VAR != IS_CONST &&
+                   EXPECTED(Z_TYPE_P(function_name) == IS_OBJECT) &&
                        Z_OBJ_HANDLER_P(function_name, get_closure) &&
                        Z_OBJ_HANDLER_P(function_name, get_closure)(function_name, &EX(called_scope), &EX(fbc), &EX(object) TSRMLS_CC) == SUCCESS) {
                        if (EX(object)) {
                                Z_ADDREF_P(EX(object));
                        }
                        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+                       CHECK_EXCEPTION();
                        ZEND_VM_NEXT_OPCODE();
-               }
-
-               if (Z_TYPE_P(function_name) != IS_STRING) {
-                       zend_error_noreturn(E_ERROR, "Function name must be a string");
-               }
-               function_name_strval = Z_STRVAL_P(function_name);
-               function_name_strlen = Z_STRLEN_P(function_name);
-               if (function_name_strval[0] == '\\') {
-
-                   function_name_strlen -= 1;
-                       lcname = zend_str_tolower_dup(function_name_strval + 1, function_name_strlen);
                } else {
-                       lcname = zend_str_tolower_dup(function_name_strval, function_name_strlen);
-               }
-               if (zend_hash_find(EG(function_table), lcname, function_name_strlen+1, (void **) &EX(fbc)) == FAILURE) {
-                       zend_error_noreturn(E_ERROR, "Call to undefined function %s()", function_name_strval);
+                       zend_error_noreturn(E_ERROR, "Function name must be a string");
                }
-               efree(lcname);
-               if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        }
-
-       EX(object) = NULL;
-       ZEND_VM_NEXT_OPCODE();
 }
 
 
 static int ZEND_FASTCALL  ZEND_BRK_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zend_brk_cont_element *el;
 
-       el = zend_brk_cont(_get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC), opline->op1.opline_num,
-                          EX(op_array), EX(Ts) TSRMLS_CC);
+       SAVE_OPLINE();
+       el = zend_brk_cont(_get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), opline->op1.opline_num,
+                          EX(op_array), EX_Ts() TSRMLS_CC);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        ZEND_VM_JMP(EX(op_array)->opcodes + el->brk);
 }
 
 static int ZEND_FASTCALL  ZEND_CONT_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zend_brk_cont_element *el;
 
-       el = zend_brk_cont(_get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC), opline->op1.opline_num,
-                          EX(op_array), EX(Ts) TSRMLS_CC);
+       SAVE_OPLINE();
+       el = zend_brk_cont(_get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), opline->op1.opline_num,
+                          EX(op_array), EX_Ts() TSRMLS_CC);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        ZEND_VM_JMP(EX(op_array)->opcodes + el->cont);
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_CLASS_SPEC_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-
+       USE_OPLINE
 
+       SAVE_OPLINE();
+       EG(exception) = NULL;
        if (IS_UNUSED == IS_UNUSED) {
                EX_T(opline->result.var).class_entry = zend_fetch_class(NULL, 0, opline->extended_value TSRMLS_CC);
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
 
@@ -1143,21 +1272,24 @@ static int ZEND_FASTCALL  ZEND_FETCH_CLASS_SPEC_UNUSED_HANDLER(ZEND_OPCODE_HANDL
                        zend_error_noreturn(E_ERROR, "Class name must be a valid object or a string");
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_CLASS_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-
+       USE_OPLINE
 
+       SAVE_OPLINE();
+       EG(exception) = NULL;
        if (IS_CV == IS_UNUSED) {
                EX_T(opline->result.var).class_entry = zend_fetch_class(NULL, 0, opline->extended_value TSRMLS_CC);
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
 
-               zval *class_name = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+               zval *class_name = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
 
                if (IS_CV == IS_CONST) {
                        EX_T(opline->result.var).class_entry = zend_fetch_class_by_name(Z_STRVAL_P(class_name), Z_STRLEN_P(class_name), opline->op2.literal + 1, opline->extended_value TSRMLS_CC);
@@ -1169,155 +1301,133 @@ static int ZEND_FASTCALL  ZEND_FETCH_CLASS_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_A
                        zend_error_noreturn(E_ERROR, "Class name must be a valid object or a string");
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_FCALL_BY_NAME_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
-       char *function_name_strval, *lcname;
-       int function_name_strlen;
-
-
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
        if (IS_CV == IS_CONST) {
-               if (zend_hash_quick_find(EG(function_table), Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv)+1, Z_HASH_P(opline->op1.zv), (void **) &EX(fbc)) == FAILURE) {
+               function_name = opline->op1.zv;
+               if (UNEXPECTED(zend_hash_quick_find(EG(function_table), Z_STRVAL_P(function_name), Z_STRLEN_P(function_name)+1, Z_HASH_P(function_name), (void **) &EX(fbc)) == FAILURE)) {
+                       SAVE_OPLINE();
                        zend_error_noreturn(E_ERROR, "Call to undefined function %s()", Z_STRVAL_P(opline->op2.zv));
                }
+               EX(object) = NULL;
+               /*CHECK_EXCEPTION();*/
+               ZEND_VM_NEXT_OPCODE();
        } else {
-               function_name = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+               char *function_name_strval, *lcname;
+               int function_name_strlen;
+
 
-               if (IS_CV != IS_CONST &&
-                   Z_TYPE_P(function_name) == IS_OBJECT &&
+               SAVE_OPLINE();
+               function_name = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+
+               if (EXPECTED(Z_TYPE_P(function_name) == IS_STRING)) {
+                       function_name_strval = Z_STRVAL_P(function_name);
+                       function_name_strlen = Z_STRLEN_P(function_name);
+                       if (function_name_strval[0] == '\\') {
+                           function_name_strlen -= 1;
+                               lcname = zend_str_tolower_dup(function_name_strval + 1, function_name_strlen);
+                       } else {
+                               lcname = zend_str_tolower_dup(function_name_strval, function_name_strlen);
+                       }
+                       if (UNEXPECTED(zend_hash_find(EG(function_table), lcname, function_name_strlen+1, (void **) &EX(fbc)) == FAILURE)) {
+                               zend_error_noreturn(E_ERROR, "Call to undefined function %s()", function_name_strval);
+                       }
+                       efree(lcname);
+
+                       EX(object) = NULL;
+                       CHECK_EXCEPTION();
+                       ZEND_VM_NEXT_OPCODE();
+               } else if (IS_CV != IS_CONST &&
+                   EXPECTED(Z_TYPE_P(function_name) == IS_OBJECT) &&
                        Z_OBJ_HANDLER_P(function_name, get_closure) &&
                        Z_OBJ_HANDLER_P(function_name, get_closure)(function_name, &EX(called_scope), &EX(fbc), &EX(object) TSRMLS_CC) == SUCCESS) {
                        if (EX(object)) {
                                Z_ADDREF_P(EX(object));
                        }
 
+                       CHECK_EXCEPTION();
                        ZEND_VM_NEXT_OPCODE();
-               }
-
-               if (Z_TYPE_P(function_name) != IS_STRING) {
-                       zend_error_noreturn(E_ERROR, "Function name must be a string");
-               }
-               function_name_strval = Z_STRVAL_P(function_name);
-               function_name_strlen = Z_STRLEN_P(function_name);
-               if (function_name_strval[0] == '\\') {
-
-                   function_name_strlen -= 1;
-                       lcname = zend_str_tolower_dup(function_name_strval + 1, function_name_strlen);
                } else {
-                       lcname = zend_str_tolower_dup(function_name_strval, function_name_strlen);
-               }
-               if (zend_hash_find(EG(function_table), lcname, function_name_strlen+1, (void **) &EX(fbc)) == FAILURE) {
-                       zend_error_noreturn(E_ERROR, "Call to undefined function %s()", function_name_strval);
+                       zend_error_noreturn(E_ERROR, "Function name must be a string");
                }
-               efree(lcname);
-
        }
-
-       EX(object) = NULL;
-       ZEND_VM_NEXT_OPCODE();
 }
 
 
-static int ZEND_FASTCALL  ZEND_CATCH_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       zend_op *opline = EX(opline);
-       zend_class_entry *ce;
-
-       /* Check whether an exception has been thrown, if not, jump over code */
-       zend_exception_restore(TSRMLS_C);
-       if (EG(exception) == NULL) {
-               ZEND_VM_SET_OPCODE(&EX(op_array)->opcodes[opline->extended_value]);
-               ZEND_VM_CONTINUE(); /* CHECK_ME */
-       }
-       ce = Z_OBJCE_P(EG(exception));
-       if (ce != EX_T(opline->op1.var).class_entry) {
-               if (!instanceof_function(ce, EX_T(opline->op1.var).class_entry TSRMLS_CC)) {
-                       if (opline->result.num) {
-                               zend_throw_exception_internal(NULL TSRMLS_CC);
-                               ZEND_VM_NEXT_OPCODE();
-                       }
-                       ZEND_VM_SET_OPCODE(&EX(op_array)->opcodes[opline->extended_value]);
-                       ZEND_VM_CONTINUE(); /* CHECK_ME */
-               }
-       }
-
-       if (!EG(active_symbol_table)) {
-               if (EX(CVs)[opline->op2.var]) {
-                       zval_ptr_dtor(EX(CVs)[opline->op2.var]);
-               }
-               EX(CVs)[opline->op2.var] = (zval**)EX(CVs) + (EX(op_array)->last_var + opline->op2.var);
-               *EX(CVs)[opline->op2.var] = EG(exception);
-       } else {
-               zend_compiled_variable *cv = &CV_DEF_OF(opline->op2.var);
-               zend_hash_quick_update(EG(active_symbol_table), cv->name, cv->name_len+1, cv->hash_value,
-                   &EG(exception), sizeof(zval *), (void**)&EX(CVs)[opline->op2.var]);
-       }
-       EG(exception) = NULL;
-       ZEND_VM_NEXT_OPCODE();
-}
-
 static int ZEND_FASTCALL  ZEND_BRK_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zend_brk_cont_element *el;
 
-       el = zend_brk_cont(_get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC), opline->op1.opline_num,
-                          EX(op_array), EX(Ts) TSRMLS_CC);
+       SAVE_OPLINE();
+       el = zend_brk_cont(_get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC), opline->op1.opline_num,
+                          EX(op_array), EX_Ts() TSRMLS_CC);
 
        ZEND_VM_JMP(EX(op_array)->opcodes + el->brk);
 }
 
 static int ZEND_FASTCALL  ZEND_CONT_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zend_brk_cont_element *el;
 
-       el = zend_brk_cont(_get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC), opline->op1.opline_num,
-                          EX(op_array), EX(Ts) TSRMLS_CC);
+       SAVE_OPLINE();
+       el = zend_brk_cont(_get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC), opline->op1.opline_num,
+                          EX(op_array), EX_Ts() TSRMLS_CC);
 
        ZEND_VM_JMP(EX(op_array)->opcodes + el->cont);
 }
 
 static int ZEND_FASTCALL  ZEND_BW_NOT_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        bitwise_not_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv TSRMLS_CC);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BOOL_NOT_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        boolean_not_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv TSRMLS_CC);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ECHO_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval z_copy;
-       zval *z = opline->op1.zv;
+       zval *z;
+
+       SAVE_OPLINE();
+       z = opline->op1.zv;
 
        if (IS_CONST != IS_CONST &&
-           Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get_method != NULL &&
+           UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) &&
+           Z_OBJ_HT_P(z)->get_method != NULL &&
                zend_std_cast_object_tostring(z, &z_copy, IS_STRING TSRMLS_CC) == SUCCESS) {
                zend_print_variable(&z_copy);
                zval_dtor(&z_copy);
@@ -1325,31 +1435,33 @@ static int ZEND_FASTCALL  ZEND_ECHO_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
                zend_print_variable(z);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_PRINT_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-
-       Z_LVAL(EX_T(opline->result.var).tmp_var) = 1;
-       Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_LONG;
+       USE_OPLINE
 
+       ZVAL_LONG(&EX_T(opline->result.var).tmp_var, 1);
        return ZEND_ECHO_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
 static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CONST(int type, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *varname = opline->op1.zv;
+       zval *varname;
        zval **retval;
        zval tmp_varname;
        HashTable *target_symbol_table;
        ulong hash_value;
 
-       if (IS_CONST != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-               tmp_varname = *varname;
+       SAVE_OPLINE();
+       varname = opline->op1.zv;
+
+       if (IS_CONST != IS_CONST && UNEXPECTED(Z_TYPE_P(varname) != IS_STRING)) {
+               ZVAL_COPY_VALUE(&tmp_varname, varname);
                zval_copy_ctor(&tmp_varname);
                convert_to_string(&tmp_varname);
                varname = &tmp_varname;
@@ -1362,6 +1474,7 @@ static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CONST(int type, ZEND
                target_symbol_table = zend_get_target_symbol_table(opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
 /*
                if (!target_symbol_table) {
+                       CHECK_EXCEPTION();
                        ZEND_VM_NEXT_OPCODE();
                }
 */
@@ -1385,12 +1498,9 @@ static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CONST(int type, ZEND
                                case BP_VAR_RW:
                                        zend_error(E_NOTICE,"Undefined variable: %s", Z_STRVAL_P(varname));
                                        /* break missing intentionally */
-                               case BP_VAR_W: {
-                                               zval *new_zval = &EG(uninitialized_zval);
-
-                                               Z_ADDREF_P(new_zval);
-                                               zend_hash_quick_update(target_symbol_table, Z_STRVAL_P(varname), Z_STRLEN_P(varname)+1, hash_value, &new_zval, sizeof(zval *), (void **) &retval);
-                                       }
+                               case BP_VAR_W:
+                                       Z_ADDREF_P(&EG(uninitialized_zval));
+                                       zend_hash_quick_update(target_symbol_table, Z_STRVAL_P(varname), Z_STRLEN_P(varname)+1, hash_value, &EG(uninitialized_zval_ptr), sizeof(zval *), (void **) &retval);
                                        break;
                                EMPTY_SWITCH_DEFAULT_CASE()
                        }
@@ -1417,7 +1527,7 @@ static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CONST(int type, ZEND
 
 
        if (IS_CONST != IS_CONST && varname == &tmp_varname) {
-               zval_dtor(varname);
+               zval_dtor(&tmp_varname);
        }
        if (RETURN_VALUE_USED(opline)) {
                if (opline->extended_value & ZEND_FETCH_MAKE_REF) {
@@ -1427,25 +1537,25 @@ static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CONST(int type, ZEND
                switch (type) {
                        case BP_VAR_R:
                        case BP_VAR_IS:
-                               AI_SET_PTR(EX_T(opline->result.var).var, *retval);
+                               AI_SET_PTR(&EX_T(opline->result.var), *retval);
                                break;
                        case BP_VAR_UNSET: {
                                zend_free_op free_res;
 
-                               EX_T(opline->result.var).var.ptr_ptr = retval;
-                               PZVAL_UNLOCK(*EX_T(opline->result.var).var.ptr_ptr, &free_res);
-                               if (EX_T(opline->result.var).var.ptr_ptr != &EG(uninitialized_zval_ptr)) {
-                                       SEPARATE_ZVAL_IF_NOT_REF(EX_T(opline->result.var).var.ptr_ptr);
+                               PZVAL_UNLOCK(*retval, &free_res);
+                               if (retval != &EG(uninitialized_zval_ptr)) {
+                                       SEPARATE_ZVAL_IF_NOT_REF(retval);
                                }
-                               PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
+                               PZVAL_LOCK(*retval);
                                FREE_OP_VAR_PTR(free_res);
-                               break;
+                       }
+                       /* break missing intentionally */
                        default:
                                EX_T(opline->result.var).var.ptr_ptr = retval;
                                break;
-                       }
                }
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -1466,7 +1576,9 @@ static int ZEND_FASTCALL  ZEND_FETCH_RW_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_A
 
 static int ZEND_FASTCALL  ZEND_FETCH_FUNC_ARG_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_var_address_helper_SPEC_CONST(ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (EX(opline)->extended_value & ZEND_FETCH_ARG_MASK))?BP_VAR_W:BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       USE_OPLINE
+
+       return zend_fetch_var_address_helper_SPEC_CONST(ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))?BP_VAR_W:BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_UNSET_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
@@ -1481,18 +1593,21 @@ static int ZEND_FASTCALL  ZEND_FETCH_IS_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_A
 
 static int ZEND_FASTCALL  ZEND_JMPZ_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *val = opline->op1.zv;
+       zval *val;
        int ret;
 
-       if (IS_CONST == IS_TMP_VAR && Z_TYPE_P(val) == IS_BOOL) {
+       SAVE_OPLINE();
+       val = opline->op1.zv;
+
+       if (IS_CONST == IS_TMP_VAR && EXPECTED(Z_TYPE_P(val) == IS_BOOL)) {
                ret = Z_LVAL_P(val);
        } else {
                ret = i_zend_is_true(val);
 
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       ZEND_VM_CONTINUE();
+                       HANDLE_EXCEPTION();
                }
        }
        if (!ret) {
@@ -1508,18 +1623,21 @@ static int ZEND_FASTCALL  ZEND_JMPZ_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 
 static int ZEND_FASTCALL  ZEND_JMPNZ_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *val = opline->op1.zv;
+       zval *val;
        int ret;
 
-       if (IS_CONST == IS_TMP_VAR && Z_TYPE_P(val) == IS_BOOL) {
+       SAVE_OPLINE();
+       val = opline->op1.zv;
+
+       if (IS_CONST == IS_TMP_VAR && EXPECTED(Z_TYPE_P(val) == IS_BOOL)) {
                ret = Z_LVAL_P(val);
        } else {
                ret = i_zend_is_true(val);
 
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       ZEND_VM_CONTINUE();
+                       HANDLE_EXCEPTION();
                }
        }
        if (ret) {
@@ -1535,18 +1653,21 @@ static int ZEND_FASTCALL  ZEND_JMPNZ_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS
 
 static int ZEND_FASTCALL  ZEND_JMPZNZ_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *val = opline->op1.zv;
+       zval *val;
        int retval;
 
-       if (IS_CONST == IS_TMP_VAR && Z_TYPE_P(val) == IS_BOOL) {
+       SAVE_OPLINE();
+       val = opline->op1.zv;
+
+       if (IS_CONST == IS_TMP_VAR && EXPECTED(Z_TYPE_P(val) == IS_BOOL)) {
                retval = Z_LVAL_P(val);
        } else {
                retval = i_zend_is_true(val);
 
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       ZEND_VM_CONTINUE();
+                       HANDLE_EXCEPTION();
                }
        }
        if (EXPECTED(retval != 0)) {
@@ -1566,18 +1687,21 @@ static int ZEND_FASTCALL  ZEND_JMPZNZ_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARG
 
 static int ZEND_FASTCALL  ZEND_JMPZ_EX_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *val = opline->op1.zv;
+       zval *val;
        int retval;
 
-       if (IS_CONST == IS_TMP_VAR && Z_TYPE_P(val) == IS_BOOL) {
+       SAVE_OPLINE();
+       val = opline->op1.zv;
+
+       if (IS_CONST == IS_TMP_VAR && EXPECTED(Z_TYPE_P(val) == IS_BOOL)) {
                retval = Z_LVAL_P(val);
        } else {
                retval = i_zend_is_true(val);
 
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       ZEND_VM_CONTINUE();
+                       HANDLE_EXCEPTION();
                }
        }
        Z_LVAL(EX_T(opline->result.var).tmp_var) = retval;
@@ -1594,18 +1718,21 @@ static int ZEND_FASTCALL  ZEND_JMPZ_EX_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_AR
 
 static int ZEND_FASTCALL  ZEND_JMPNZ_EX_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *val = opline->op1.zv;
+       zval *val;
        int retval;
 
-       if (IS_CONST == IS_TMP_VAR && Z_TYPE_P(val) == IS_BOOL) {
+       SAVE_OPLINE();
+       val = opline->op1.zv;
+
+       if (IS_CONST == IS_TMP_VAR && EXPECTED(Z_TYPE_P(val) == IS_BOOL)) {
                retval = Z_LVAL_P(val);
        } else {
                retval = i_zend_is_true(val);
 
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       ZEND_VM_CONTINUE();
+                       HANDLE_EXCEPTION();
                }
        }
        Z_LVAL(EX_T(opline->result.var).tmp_var) = retval;
@@ -1622,13 +1749,14 @@ static int ZEND_FASTCALL  ZEND_JMPNZ_EX_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_A
 
 static int ZEND_FASTCALL  ZEND_DO_FCALL_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *fname = opline->op1.zv;
 
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
-       if (zend_hash_quick_find(EG(function_table), Z_STRVAL_P(fname), Z_STRLEN_P(fname)+1, Z_HASH_P(fname), (void **) &EX(function_state).function)==FAILURE) {
+       if (UNEXPECTED(zend_hash_quick_find(EG(function_table), Z_STRVAL_P(fname), Z_STRLEN_P(fname)+1, Z_HASH_P(fname), (void **) &EX(function_state).function)==FAILURE)) {
+           SAVE_OPLINE();
                zend_error_noreturn(E_ERROR, "Call to undefined function %s()", fname->value.str.val);
        }
        EX(object) = NULL;
@@ -1638,12 +1766,13 @@ static int ZEND_FASTCALL  ZEND_DO_FCALL_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_A
 
 static int ZEND_FASTCALL  ZEND_RETURN_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *retval_ptr;
        zval **retval_ptr_ptr;
 
 
-       if (EG(active_op_array)->return_reference == ZEND_RETURN_REF) {
+       SAVE_OPLINE();
+       if (UNEXPECTED(EG(active_op_array)->return_reference == ZEND_RETURN_REF)) {
 
                if (IS_CONST == IS_CONST || IS_CONST == IS_TMP_VAR) {
                        /* Not supposed to happen, but we'll allow it */
@@ -1653,7 +1782,7 @@ static int ZEND_FASTCALL  ZEND_RETURN_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARG
 
                retval_ptr_ptr = NULL;
 
-               if (IS_CONST == IS_VAR && !retval_ptr_ptr) {
+               if (IS_CONST == IS_VAR && UNEXPECTED(retval_ptr_ptr == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot return string offsets by reference");
                }
 
@@ -1675,6 +1804,8 @@ static int ZEND_FASTCALL  ZEND_RETURN_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARG
 
                        (*EG(return_value_ptr_ptr)) = (*retval_ptr_ptr);
                }
+
+               return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else {
 return_by_value:
 
@@ -1705,21 +1836,22 @@ return_by_value:
                        INIT_PZVAL_COPY(ret, retval_ptr);
                        *EG(return_value_ptr_ptr) = ret;
                }
-       }
 
-       return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
 }
 
 static int ZEND_FASTCALL  ZEND_THROW_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *value;
        zval *exception;
 
 
+       SAVE_OPLINE();
        value = opline->op1.zv;
 
-       if (IS_CONST == IS_CONST || Z_TYPE_P(value) != IS_OBJECT) {
+       if (IS_CONST == IS_CONST || UNEXPECTED(Z_TYPE_P(value) != IS_OBJECT)) {
                zend_error_noreturn(E_ERROR, "Can only throw objects");
        }
        zend_exception_save(TSRMLS_C);
@@ -1733,12 +1865,14 @@ static int ZEND_FASTCALL  ZEND_THROW_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS
        zend_throw_exception_object(exception TSRMLS_CC);
        zend_exception_restore(TSRMLS_C);
 
-       ZEND_VM_NEXT_OPCODE();
+       HANDLE_EXCEPTION();
 }
 
 static int ZEND_FASTCALL  ZEND_SEND_VAL_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       SAVE_OPLINE();
        if (opline->extended_value==ZEND_DO_FCALL_BY_NAME
                && ARG_MUST_BE_SENT_BY_REF(EX(fbc), opline->op2.opline_num)) {
                        zend_error_noreturn(E_ERROR, "Cannot pass parameter %d by reference", opline->op2.opline_num);
@@ -1758,40 +1892,46 @@ static int ZEND_FASTCALL  ZEND_SEND_VAL_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_A
                zend_vm_stack_push(valptr TSRMLS_CC);
 
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BOOL_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
+       zval *retval = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        /* PHP 3.0 returned "" for false and 1 for true, here we use 0 and 1 for now */
-       Z_LVAL(EX_T(opline->result.var).tmp_var) = i_zend_is_true(opline->op1.zv);
-       Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
+       ZVAL_BOOL(retval, i_zend_is_true(opline->op1.zv));
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CLONE_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *obj = opline->op1.zv;
+       zval *obj;
        zend_class_entry *ce;
        zend_function *clone;
        zend_object_clone_obj_t clone_call;
 
+       SAVE_OPLINE();
+       obj = opline->op1.zv;
+
        if (IS_CONST == IS_CONST ||
-           (IS_CONST == IS_VAR && !obj) ||
-           Z_TYPE_P(obj) != IS_OBJECT) {
+           (IS_CONST == IS_VAR && UNEXPECTED(obj == NULL)) ||
+           UNEXPECTED(Z_TYPE_P(obj) != IS_OBJECT)) {
                zend_error_noreturn(E_ERROR, "__clone method called on non-object");
        }
 
        ce = Z_OBJCE_P(obj);
        clone = ce ? ce->clone : NULL;
        clone_call =  Z_OBJ_HT_P(obj)->clone_obj;
-       if (!clone_call) {
+       if (UNEXPECTED(clone_call == NULL)) {
                if (ce) {
                        zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object of class %s", ce->name);
                } else {
@@ -1803,42 +1943,49 @@ static int ZEND_FASTCALL  ZEND_CLONE_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS
                if (clone->op_array.fn_flags & ZEND_ACC_PRIVATE) {
                        /* Ensure that if we're calling a private function, we're allowed to do so.
                         */
-                       if (ce != EG(scope)) {
+                       if (UNEXPECTED(ce != EG(scope))) {
                                zend_error_noreturn(E_ERROR, "Call to private %s::__clone() from context '%s'", ce->name, EG(scope) ? EG(scope)->name : "");
                        }
                } else if ((clone->common.fn_flags & ZEND_ACC_PROTECTED)) {
                        /* Ensure that if we're calling a protected function, we're allowed to do so.
                         */
-                       if (!zend_check_protected(clone->common.scope, EG(scope))) {
+                       if (UNEXPECTED(!zend_check_protected(clone->common.scope, EG(scope)))) {
                                zend_error_noreturn(E_ERROR, "Call to protected %s::__clone() from context '%s'", ce->name, EG(scope) ? EG(scope)->name : "");
                        }
                }
        }
 
-       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-       if (!EG(exception)) {
-               ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-               Z_OBJVAL_P(EX_T(opline->result.var).var.ptr) = clone_call(obj TSRMLS_CC);
-               Z_TYPE_P(EX_T(opline->result.var).var.ptr) = IS_OBJECT;
-               Z_SET_REFCOUNT_P(EX_T(opline->result.var).var.ptr, 1);
-               Z_SET_ISREF_P(EX_T(opline->result.var).var.ptr);
-               if (!RETURN_VALUE_USED(opline) || EG(exception)) {
-                       zval_ptr_dtor(&EX_T(opline->result.var).var.ptr);
+       if (EXPECTED(EG(exception) == NULL)) {
+               zval *retval;
+
+               ALLOC_ZVAL(retval);
+               Z_OBJVAL_P(retval) = clone_call(obj TSRMLS_CC);
+               Z_TYPE_P(retval) = IS_OBJECT;
+               Z_SET_REFCOUNT_P(retval, 1);
+               Z_SET_ISREF_P(retval);
+               if (!RETURN_VALUE_USED(opline) || UNEXPECTED(EG(exception) != NULL)) {
+                       zval_ptr_dtor(&retval);
+               } else {
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CAST_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *expr = opline->op1.zv;
+       zval *expr;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
+       expr = opline->op1.zv;
+
        if (opline->extended_value != IS_STRING) {
-               *result = *expr;
+               ZVAL_COPY_VALUE(result, expr);
                if (!0) {
                        zendi_zval_copy_ctor(*result);
                }
@@ -1862,12 +2009,12 @@ static int ZEND_FASTCALL  ZEND_CAST_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 
                        zend_make_printable_zval(expr, &var_copy, &use_copy);
                        if (use_copy) {
-                               *result = var_copy;
+                               ZVAL_COPY_VALUE(result, &var_copy);
                                if (0) {
 
                                }
                        } else {
-                               *result = *expr;
+                               ZVAL_COPY_VALUE(result, expr);
                                if (!0) {
                                        zendi_zval_copy_ctor(*result);
                                }
@@ -1882,28 +2029,29 @@ static int ZEND_FASTCALL  ZEND_CAST_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
                        break;
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INCLUDE_OR_EVAL_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_op_array *new_op_array=NULL;
-       int return_value_used;
 
-       zval *inc_filename = opline->op1.zv;
+       zval *inc_filename;
        zval tmp_inc_filename;
        zend_bool failure_retval=0;
 
+       SAVE_OPLINE();
+       inc_filename = opline->op1.zv;
+
        if (inc_filename->type!=IS_STRING) {
-               tmp_inc_filename = *inc_filename;
+               ZVAL_COPY_VALUE(&tmp_inc_filename, inc_filename);
                zval_copy_ctor(&tmp_inc_filename);
                convert_to_string(&tmp_inc_filename);
                inc_filename = &tmp_inc_filename;
        }
 
-       return_value_used = RETURN_VALUE_USED(opline);
-
        switch (opline->extended_value) {
                case ZEND_INCLUDE_ONCE:
                case ZEND_REQUIRE_ONCE: {
@@ -1961,12 +2109,18 @@ static int ZEND_FASTCALL  ZEND_INCLUDE_OR_EVAL_SPEC_CONST_HANDLER(ZEND_OPCODE_HA
                zval_dtor(&tmp_inc_filename);
        }
 
-       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-       if (new_op_array && !EG(exception)) {
+       if (UNEXPECTED(EG(exception) != NULL)) {
+               HANDLE_EXCEPTION();
+       } else if (EXPECTED(new_op_array != NULL)) {
                EX(original_return_value) = EG(return_value_ptr_ptr);
-               EG(return_value_ptr_ptr) = return_value_used ? EX_T(opline->result.var).var.ptr_ptr : NULL;
                EG(active_op_array) = new_op_array;
-               EX_T(opline->result.var).var.ptr = NULL;
+               if (RETURN_VALUE_USED(opline)) {
+                       EX_T(opline->result.var).var.ptr = NULL;
+                       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
+                       EG(return_value_ptr_ptr) = EX_T(opline->result.var).var.ptr_ptr;
+               } else {
+                       EG(return_value_ptr_ptr) = NULL;
+               }
 
                EX(current_object) = EX(object);
 
@@ -1977,8 +2131,7 @@ static int ZEND_FASTCALL  ZEND_INCLUDE_OR_EVAL_SPEC_CONST_HANDLER(ZEND_OPCODE_HA
                        zend_rebuild_symbol_table(TSRMLS_C);
                }
 
-               if (zend_execute == execute) {
-                       EX(call_opline) = opline;
+               if (EXPECTED(zend_execute == execute)) {
                        ZEND_VM_ENTER();
                } else {
                        zend_execute(new_op_array TSRMLS_CC);
@@ -1987,75 +2140,62 @@ static int ZEND_FASTCALL  ZEND_INCLUDE_OR_EVAL_SPEC_CONST_HANDLER(ZEND_OPCODE_HA
                EX(function_state).function = (zend_function *) EX(op_array);
                EX(object) = EX(current_object);
 
-               if (return_value_used) {
-                       if (!EX_T(opline->result.var).var.ptr) { /* there was no return statement */
-                               ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                               INIT_PZVAL(EX_T(opline->result.var).var.ptr);
-                               Z_LVAL_P(EX_T(opline->result.var).var.ptr) = 1;
-                               Z_TYPE_P(EX_T(opline->result.var).var.ptr) = IS_BOOL;
-                       }
-               }
-
                EG(opline_ptr) = &EX(opline);
                EG(active_op_array) = EX(op_array);
                EG(return_value_ptr_ptr) = EX(original_return_value);
                destroy_op_array(new_op_array TSRMLS_CC);
                efree(new_op_array);
-               if (EG(exception)) {
+               if (UNEXPECTED(EG(exception) != NULL)) {
                        zend_throw_exception_internal(NULL TSRMLS_CC);
+                       HANDLE_EXCEPTION();
+               } else if (RETURN_VALUE_USED(opline)) {
+                       if (!EX_T(opline->result.var).var.ptr) { /* there was no return statement */
+                               zval *retval;
+
+                               ALLOC_ZVAL(retval);
+                               ZVAL_BOOL(retval, 1);
+                               INIT_PZVAL(retval);
+                               EX_T(opline->result.var).var.ptr = retval;
+                       }
                }
-       } else {
-               if (return_value_used) {
-                       ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                       INIT_ZVAL(*EX_T(opline->result.var).var.ptr);
-                       Z_LVAL_P(EX_T(opline->result.var).var.ptr) = failure_retval;
-                       Z_TYPE_P(EX_T(opline->result.var).var.ptr) = IS_BOOL;
-               }
+
+       } else if (RETURN_VALUE_USED(opline)) {
+               zval *retval;
+
+               ALLOC_ZVAL(retval);
+               ZVAL_BOOL(retval, failure_retval);
+               INIT_PZVAL(retval);
+               AI_SET_PTR(&EX_T(opline->result.var), retval);
        }
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval tmp, *varname;
        HashTable *target_symbol_table;
 
 
+       SAVE_OPLINE();
        if (IS_CONST == IS_CV && (opline->extended_value & ZEND_QUICK_SET)) {
                if (EG(active_symbol_table)) {
-                       zend_execute_data *ex = EX(prev_execute_data);
                        zend_compiled_variable *cv = &CV_DEF_OF(opline->op1.var);
 
-                       if (zend_hash_quick_del(EG(active_symbol_table), cv->name, cv->name_len+1, cv->hash_value) == SUCCESS) {
-                               while (ex && ex->symbol_table == EG(active_symbol_table)) {
-                                       int i;
-
-                                       if (ex->op_array) {
-                                               for (i = 0; i < ex->op_array->last_var; i++) {
-                                                       if (ex->op_array->vars[i].hash_value == cv->hash_value &&
-                                                               ex->op_array->vars[i].name_len == cv->name_len &&
-                                                               !memcmp(ex->op_array->vars[i].name, cv->name, cv->name_len)) {
-                                                               ex->CVs[i] = NULL;
-                                                               break;
-                                                       }
-                                               }
-                                       }
-                                       ex = ex->prev_execute_data;
-                               }
-                       }
-                       EX(CVs)[opline->op1.var] = NULL;
-               } else if (EX(CVs)[opline->op1.var]) {
-                       zval_ptr_dtor(EX(CVs)[opline->op1.var]);
-                       EX(CVs)[opline->op1.var] = NULL;
+                       zend_delete_variable(EX(prev_execute_data), EG(active_symbol_table),  cv->name, cv->name_len+1, cv->hash_value TSRMLS_CC);
+                       EX_CV(opline->op1.var) = NULL;
+               } else if (EX_CV(opline->op1.var)) {
+                       zval_ptr_dtor(EX_CV(opline->op1.var));
+                       EX_CV(opline->op1.var) = NULL;
                }
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
        varname = opline->op1.zv;
 
        if (IS_CONST != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-               tmp = *varname;
+               ZVAL_COPY_VALUE(&tmp, varname);
                zval_copy_ctor(&tmp);
                convert_to_string(&tmp);
                varname = &tmp;
@@ -2069,39 +2209,22 @@ static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_
                ulong hash_value = zend_inline_hash_func(varname->value.str.val, varname->value.str.len+1);
 
                target_symbol_table = zend_get_target_symbol_table(opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-               if (zend_hash_quick_del(target_symbol_table, varname->value.str.val, varname->value.str.len+1, hash_value) == SUCCESS) {
-                       zend_execute_data *ex = execute_data;
-
-                       do {
-                               int i;
-
-                               if (ex->op_array) {
-                                       for (i = 0; i < ex->op_array->last_var; i++) {
-                                               if (ex->op_array->vars[i].hash_value == hash_value &&
-                                                       ex->op_array->vars[i].name_len == varname->value.str.len &&
-                                                       !memcmp(ex->op_array->vars[i].name, varname->value.str.val, varname->value.str.len)) {
-                                                       ex->CVs[i] = NULL;
-                                                       break;
-                                               }
-                                       }
-                               }
-                               ex = ex->prev_execute_data;
-                       } while (ex && ex->symbol_table == target_symbol_table);
-               }
+               zend_delete_variable(execute_data, target_symbol_table, varname->value.str.val, varname->value.str.len+1, hash_value TSRMLS_CC);
        }
 
-       if (varname == &tmp) {
+       if (IS_CONST != IS_CONST && varname == &tmp) {
                zval_dtor(&tmp);
        } else if (IS_CONST == IS_VAR || IS_CONST == IS_CV) {
                zval_ptr_dtor(&varname);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *array_ptr, **array_ptr_ptr;
        HashTable *fe_ht;
@@ -2109,10 +2232,13 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_A
        zend_class_entry *ce = NULL;
        zend_bool is_empty = 0;
 
+       SAVE_OPLINE();
+
        if (opline->extended_value & ZEND_FE_RESET_VARIABLE) {
                array_ptr_ptr = NULL;
                if (array_ptr_ptr == NULL || array_ptr_ptr == &EG(uninitialized_zval_ptr)) {
-                       ALLOC_INIT_ZVAL(array_ptr);
+                       MAKE_STD_ZVAL(array_ptr);
+                       ZVAL_NULL(array_ptr);
                } else if (Z_TYPE_PP(array_ptr_ptr) == IS_OBJECT) {
                        if(Z_OBJ_HT_PP(array_ptr_ptr)->get_class_entry == NULL) {
                                zend_error(E_WARNING, "foreach() cannot iterate over objects without PHP class");
@@ -2172,7 +2298,7 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_A
        if (ce && ce->get_iterator) {
                iter = ce->get_iterator(ce, array_ptr, opline->extended_value & ZEND_FE_RESET_REFERENCE TSRMLS_CC);
 
-               if (iter && !EG(exception)) {
+               if (iter && EXPECTED(EG(exception) == NULL)) {
                        array_ptr = zend_iterator_wrap(iter TSRMLS_CC);
                } else {
                        if (opline->extended_value & ZEND_FE_RESET_VARIABLE) {
@@ -2184,18 +2310,18 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_A
                                zend_throw_exception_ex(NULL, 0 TSRMLS_CC, "Object of type %s did not create an Iterator", ce->name);
                        }
                        zend_throw_exception_internal(NULL TSRMLS_CC);
-                       ZEND_VM_NEXT_OPCODE();
+                       HANDLE_EXCEPTION();
                }
        }
 
-       AI_SET_PTR(EX_T(opline->result.var).var, array_ptr);
        PZVAL_LOCK(array_ptr);
+       AI_SET_PTR(&EX_T(opline->result.var), array_ptr);
 
        if (iter) {
                iter->index = 0;
                if (iter->funcs->rewind) {
                        iter->funcs->rewind(iter TSRMLS_CC);
-                       if (EG(exception)) {
+                       if (UNEXPECTED(EG(exception) != NULL)) {
                                Z_DELREF_P(array_ptr);
                                zval_ptr_dtor(&array_ptr);
                                if (opline->extended_value & ZEND_FE_RESET_VARIABLE) {
@@ -2203,11 +2329,11 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_A
                                } else {
 
                                }
-                               ZEND_VM_NEXT_OPCODE();
+                               HANDLE_EXCEPTION();
                        }
                }
                is_empty = iter->funcs->valid(iter TSRMLS_CC) != SUCCESS;
-               if (EG(exception)) {
+               if (UNEXPECTED(EG(exception) != NULL)) {
                        Z_DELREF_P(array_ptr);
                        zval_ptr_dtor(&array_ptr);
                        if (opline->extended_value & ZEND_FE_RESET_VARIABLE) {
@@ -2215,7 +2341,7 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_A
                        } else {
 
                        }
-                       ZEND_VM_NEXT_OPCODE();
+                       HANDLE_EXCEPTION();
                }
                iter->index = -1; /* will be set to 0 before using next handler */
        } else if ((fe_ht = HASH_OF(array_ptr)) != NULL) {
@@ -2252,19 +2378,21 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_A
        if (is_empty) {
                ZEND_VM_JMP(EX(op_array)->opcodes+opline->op2.opline_num);
        } else {
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 }
 
 static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval **value;
        zend_bool isset = 1;
 
+       SAVE_OPLINE();
        if (IS_CONST == IS_CV && (opline->extended_value & ZEND_QUICK_SET)) {
-               if (EX(CVs)[opline->op1.var]) {
-                       value = EX(CVs)[opline->op1.var];
+               if (EX_CV(opline->op1.var)) {
+                       value = EX_CV(opline->op1.var);
                } else if (EG(active_symbol_table)) {
                        zend_compiled_variable *cv = &CV_DEF_OF(opline->op1.var);
 
@@ -2280,7 +2408,7 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_CONST_HANDLER(ZEND_OPCODE_
                zval tmp, *varname = opline->op1.zv;
 
                if (IS_CONST != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-                       tmp = *varname;
+                       ZVAL_COPY_VALUE(&tmp, varname);
                        zval_copy_ctor(&tmp);
                        convert_to_string(&tmp);
                        varname = &tmp;
@@ -2298,35 +2426,36 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_CONST_HANDLER(ZEND_OPCODE_
                        }
                }
 
-               if (varname == &tmp) {
+               if (IS_CONST != IS_CONST && varname == &tmp) {
                        zval_dtor(&tmp);
                }
 
        }
 
-       Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
-
        if (opline->extended_value & ZEND_ISSET) {
-               if (isset && Z_TYPE_PP(value) == IS_NULL) {
-                       Z_LVAL(EX_T(opline->result.var).tmp_var) = 0;
+               if (isset && Z_TYPE_PP(value) != IS_NULL) {
+                       ZVAL_BOOL(&EX_T(opline->result.var).tmp_var, 1);
                } else {
-                       Z_LVAL(EX_T(opline->result.var).tmp_var) = isset;
+                       ZVAL_BOOL(&EX_T(opline->result.var).tmp_var, 0);
                }
        } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
                if (!isset || !i_zend_is_true(*value)) {
-                       Z_LVAL(EX_T(opline->result.var).tmp_var) = 1;
+                       ZVAL_BOOL(&EX_T(opline->result.var).tmp_var, 1);
                } else {
-                       Z_LVAL(EX_T(opline->result.var).tmp_var) = 0;
+                       ZVAL_BOOL(&EX_T(opline->result.var).tmp_var, 0);
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_EXIT_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
 #if 0 || (IS_CONST != IS_UNUSED)
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       SAVE_OPLINE();
        if (IS_CONST != IS_UNUSED) {
 
                zval *ptr = opline->op1.zv;
@@ -2340,17 +2469,20 @@ static int ZEND_FASTCALL  ZEND_EXIT_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
        }
 #endif
        zend_bailout();
-       ZEND_VM_NEXT_OPCODE();
+       ZEND_VM_NEXT_OPCODE(); /* Never reached */
 }
 
 static int ZEND_FASTCALL  ZEND_JMP_SET_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       zval *value;
 
-       zval *value = opline->op1.zv;
+       SAVE_OPLINE();
+       value = opline->op1.zv;
 
        if (i_zend_is_true(value)) {
-               EX_T(opline->result.var).tmp_var = *value;
+               ZVAL_COPY_VALUE(&EX_T(opline->result.var).tmp_var, value);
                zendi_zval_copy_ctor(EX_T(opline->result.var).tmp_var);
 
 #if DEBUG_ZEND>=2
@@ -2359,301 +2491,347 @@ static int ZEND_FASTCALL  ZEND_JMP_SET_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_AR
                ZEND_VM_JMP(opline->op2.jmp_addr);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_QM_ASSIGN_SPEC_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       zval *value;
 
-       zval *value = opline->op1.zv;
+       SAVE_OPLINE();
+       value = opline->op1.zv;
 
-       EX_T(opline->result.var).tmp_var = *value;
+       ZVAL_COPY_VALUE(&EX_T(opline->result.var).tmp_var, value);
        if (!0) {
                zval_copy_ctor(&EX_T(opline->result.var).tmp_var);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        add_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SUB_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        sub_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MUL_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        mul_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_DIV_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        div_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MOD_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        mod_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SL_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        shift_left_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SR_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        shift_right_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        concat_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        is_identical_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        is_identical_function(result,
                opline->op1.zv,
                opline->op2.zv TSRMLS_CC);
        Z_LVAL_P(result) = !Z_LVAL_P(result);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
                opline->op1.zv,
                opline->op2.zv TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) == 0));
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
                opline->op1.zv,
                opline->op2.zv TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) != 0));
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
                opline->op1.zv,
                opline->op2.zv TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) < 0));
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
                opline->op1.zv,
                opline->op2.zv TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) <= 0));
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        bitwise_or_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        bitwise_and_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        bitwise_xor_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        boolean_xor_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_TMP_VAR_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       zval *container;
 
-       zval *container = opline->op1.zv;
+       SAVE_OPLINE();
+       container = opline->op1.zv;
 
-       if (Z_TYPE_P(container) != IS_ARRAY) {
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_ARRAY)) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
        } else {
 
-               zval *dim = opline->op2.zv;
+               zval *value = *zend_fetch_dimension_address_inner(Z_ARRVAL_P(container), opline->op2.zv, IS_CONST, BP_VAR_R TSRMLS_CC);
 
-               AI_SET_PTR(EX_T(opline->result.var).var, *zend_fetch_dimension_address_inner(Z_ARRVAL_P(container), dim, IS_CONST, BP_VAR_R TSRMLS_CC));
-               SELECTIVE_PZVAL_LOCK(EX_T(opline->result.var).var.ptr, opline);
+               SELECTIVE_PZVAL_LOCK(value, opline);
+               AI_SET_PTR(&EX_T(opline->result.var), value);
 
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        zend_class_entry *ce;
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
        if (IS_CONST == IS_CONST) {
                /* no function found. try a static method in class */
                ce = zend_fetch_class_by_name(Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), opline->op1.literal + 1, opline->extended_value TSRMLS_CC);
-               if (!ce) {
+               if (UNEXPECTED(ce == NULL)) {
                        zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
                }
                EX(called_scope) = ce;
@@ -2677,7 +2855,7 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_CONST_HANDLER(
                } else {
                        function_name = opline->op2.zv;
 
-                       if (Z_TYPE_P(function_name) != IS_STRING) {
+                       if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                                zend_error_noreturn(E_ERROR, "Function name must be a string");
                        } else {
                                function_name_strval = Z_STRVAL_P(function_name);
@@ -2691,7 +2869,7 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_CONST_HANDLER(
                        } else {
                                EX(fbc) = zend_std_get_static_method(ce, function_name_strval, function_name_strlen, ((IS_CONST == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
                        }
-                       if (!EX(fbc)) {
+                       if (UNEXPECTED(EX(fbc) == NULL)) {
                                zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name, function_name_strval);
                        }
                }
@@ -2700,11 +2878,11 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_CONST_HANDLER(
 
                }
        } else {
-               if(!ce->constructor) {
+               if (UNEXPECTED(ce->constructor == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot call constructor");
                }
                if (EG(This) && Z_OBJCE_P(EG(This)) != ce->constructor->common.scope && (ce->constructor->common.fn_flags & ZEND_ACC_PRIVATE)) {
-                       zend_error(E_COMPILE_ERROR, "Cannot call private %s::__construct()", ce->name);
+                       zend_error_noreturn(E_ERROR, "Cannot call private %s::__construct()", ce->name);
                }
                EX(fbc) = ce->constructor;
        }
@@ -2736,15 +2914,17 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_CONST_HANDLER(
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CASE_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        int switch_expr_is_overloaded=0;
 
 
+       SAVE_OPLINE();
        if (IS_CONST==IS_VAR) {
                if (EX_T(opline->op1.var).var.ptr_ptr) {
                        PZVAL_LOCK(EX_T(opline->op1.var).var.ptr);
@@ -2767,13 +2947,15 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER
                EX_T(opline->op1.var).var.ptr_ptr = NULL;
                EX_T(opline->op1.var).var.ptr = NULL;
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_CONSTANT_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
+       SAVE_OPLINE();
        if (IS_CONST == IS_UNUSED) {
                /* namespaced constant */
                if (!zend_get_constant_ex(Z_STRVAL_P(opline->op2.zv), Z_STRLEN_P(opline->op2.zv), &EX_T(opline->result.var).tmp_var, NULL, opline->extended_value TSRMLS_CC)) {
@@ -2788,10 +2970,10 @@ static int ZEND_FASTCALL  ZEND_FETCH_CONSTANT_SPEC_CONST_CONST_HANDLER(ZEND_OPCO
                                zend_error(E_NOTICE, "Use of undefined constant %s - assumed '%s'", actual, actual);
                                ZVAL_STRINGL(&EX_T(opline->result.var).tmp_var, actual, Z_STRLEN_P(opline->op2.zv)-(actual - Z_STRVAL_P(opline->op2.zv)), 1);
                        } else {
-                               zend_error_noreturn(E_ERROR, "Undefined constant '%s'",
-                                                       Z_STRVAL_P(opline->op2.zv), Z_STRVAL_P(opline->op2.zv));
+                               zend_error_noreturn(E_ERROR, "Undefined constant '%s'", Z_STRVAL_P(opline->op2.zv));
                        }
                }
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
                /* class constant */
@@ -2801,14 +2983,14 @@ static int ZEND_FASTCALL  ZEND_FETCH_CONSTANT_SPEC_CONST_CONST_HANDLER(ZEND_OPCO
                if (IS_CONST == IS_CONST) {
 
                        ce = zend_fetch_class_by_name(Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), opline->op1.literal + 1, opline->extended_value TSRMLS_CC);
-                       if (!ce) {
+                       if (UNEXPECTED(ce == NULL)) {
                                zend_error_noreturn(E_ERROR, "Undefined class constant '%s'", Z_STRVAL_P(opline->op2.zv));
                        }
                } else {
                        ce = EX_T(opline->op1.var).class_entry;
                }
 
-               if (zend_hash_quick_find(&ce->constants_table, Z_STRVAL_P(opline->op2.zv), Z_STRLEN_P(opline->op2.zv)+1, Z_HASH_P(opline->op2.zv), (void **) &value) == SUCCESS) {
+               if (EXPECTED(zend_hash_quick_find(&ce->constants_table, Z_STRVAL_P(opline->op2.zv), Z_STRLEN_P(opline->op2.zv)+1, Z_HASH_P(opline->op2.zv), (void **) &value) == SUCCESS)) {
                        if (Z_TYPE_PP(value) == IS_CONSTANT_ARRAY ||
                            (Z_TYPE_PP(value) & IS_CONSTANT_TYPE_MASK) == IS_CONSTANT) {
                                zend_class_entry *old_scope = EG(scope);
@@ -2817,54 +2999,39 @@ static int ZEND_FASTCALL  ZEND_FETCH_CONSTANT_SPEC_CONST_CONST_HANDLER(ZEND_OPCO
                                zval_update_constant(value, (void *) 1 TSRMLS_CC);
                                EG(scope) = old_scope;
                        }
-                       EX_T(opline->result.var).tmp_var = **value;
+                       ZVAL_COPY_VALUE(&EX_T(opline->result.var).tmp_var, *value);
                        zval_copy_ctor(&EX_T(opline->result.var).tmp_var);
                } else {
                        zend_error_noreturn(E_ERROR, "Undefined class constant '%s'", Z_STRVAL_P(opline->op2.zv));
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *array_ptr = &EX_T(opline->result.var).tmp_var;
        zval *expr_ptr;
-       zval *offset=opline->op2.zv;
-       ulong hval;
-       long index;
 
-#if 0 || IS_CONST == IS_VAR || IS_CONST == IS_CV
-       zval **expr_ptr_ptr = NULL;
+       SAVE_OPLINE();
+       if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) && opline->extended_value) {
+               zval **expr_ptr_ptr = NULL;
 
-       if (opline->extended_value) {
-               expr_ptr_ptr=NULL;
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
                expr_ptr = *expr_ptr_ptr;
+               Z_ADDREF_P(expr_ptr);
        } else {
                expr_ptr=opline->op1.zv;
-       }
-#else
-       expr_ptr=opline->op1.zv;
-#endif
-
-       if (0) { /* temporary variable */
-               zval *new_expr;
+               if (0) { /* temporary variable */
+                       zval *new_expr;
 
-               ALLOC_ZVAL(new_expr);
-               INIT_PZVAL_COPY(new_expr, expr_ptr);
-               expr_ptr = new_expr;
-       } else {
-#if 0 || IS_CONST == IS_VAR || IS_CONST == IS_CV
-               if (opline->extended_value) {
-                       SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
-                       expr_ptr = *expr_ptr_ptr;
-                       Z_ADDREF_P(expr_ptr);
-               } else
-#endif
-               if (IS_CONST == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
+                       ALLOC_ZVAL(new_expr);
+                       INIT_PZVAL_COPY(new_expr, expr_ptr);
+                       expr_ptr = new_expr;
+               } else if (IS_CONST == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
                        zval *new_expr;
 
                        ALLOC_ZVAL(new_expr);
@@ -2875,7 +3042,13 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_CONST_HANDLER(ZEND_O
                        Z_ADDREF_P(expr_ptr);
                }
        }
-       if (offset) {
+
+       if (IS_CONST != IS_UNUSED) {
+
+               zval *offset = opline->op2.zv;
+               ulong hval;
+               long index;
+
                switch (Z_TYPE_P(offset)) {
                        case IS_DOUBLE:
                                index = zend_dval_to_lval(Z_DVAL_P(offset));
@@ -2884,7 +3057,7 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_CONST_HANDLER(ZEND_O
                        case IS_BOOL:
                                index = Z_LVAL_P(offset);
 num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(array_ptr), index, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_index_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), index, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_STRING:
                                if (IS_CONST == IS_CONST) {
@@ -2897,10 +3070,10 @@ num_index:
                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                        }
                                }
-                               zend_hash_quick_update(Z_ARRVAL_P(array_ptr), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_quick_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_NULL:
-                               zend_hash_update(Z_ARRVAL_P(array_ptr), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
                                break;
                        default:
                                zend_error(E_WARNING, "Illegal offset type");
@@ -2910,19 +3083,20 @@ num_index:
                }
 
        } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(array_ptr), &expr_ptr, sizeof(zval *), NULL);
+               zend_hash_next_index_insert(Z_ARRVAL(EX_T(opline->result.var).tmp_var), &expr_ptr, sizeof(zval *), NULL);
        }
-       if (opline->extended_value) {
+       if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) && opline->extended_value) {
 
        } else {
 
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (IS_CONST == IS_UNUSED) {
@@ -2936,16 +3110,21 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_H
 
 static int ZEND_FASTCALL  ZEND_DECLARE_CONST_SPEC_CONST_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *name  = opline->op1.zv;
-       zval *val   = opline->op2.zv;
+       zval *name;
+       zval *val;
        zend_constant c;
 
+       SAVE_OPLINE();
+       name  = opline->op1.zv;
+       val   = opline->op2.zv;
+
        if ((Z_TYPE_P(val) & IS_CONSTANT_TYPE_MASK) == IS_CONSTANT || Z_TYPE_P(val) == IS_CONSTANT_ARRAY) {
-               zval tmp = *val;
+               zval tmp;
                zval *tmp_ptr = &tmp;
 
+               ZVAL_COPY_VALUE(&tmp, val);
                if (Z_TYPE_P(val) == IS_CONSTANT_ARRAY) {
                        zval_copy_ctor(&tmp);
                }
@@ -2953,7 +3132,7 @@ static int ZEND_FASTCALL  ZEND_DECLARE_CONST_SPEC_CONST_CONST_HANDLER(ZEND_OPCOD
                zval_update_constant(&tmp_ptr, NULL TSRMLS_CC);
                c.value = *tmp_ptr;
        } else {
-               c.value = *val;
+               INIT_PZVAL_COPY(&c.value, val);
                zval_copy_ctor(&c.value);
        }
        c.flags = CONST_CS; /* non persistent, case sensetive */
@@ -2965,265 +3144,303 @@ static int ZEND_FASTCALL  ZEND_DECLARE_CONST_SPEC_CONST_CONST_HANDLER(ZEND_OPCOD
        }
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        add_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SUB_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        sub_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MUL_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        mul_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_DIV_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        div_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MOD_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        mod_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SL_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        shift_left_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SR_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        shift_right_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        concat_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        is_identical_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        is_identical_function(result,
                opline->op1.zv,
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        Z_LVAL_P(result) = !Z_LVAL_P(result);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
                opline->op1.zv,
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) == 0));
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
                opline->op1.zv,
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) != 0));
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
                opline->op1.zv,
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) < 0));
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
                opline->op1.zv,
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) <= 0));
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        bitwise_or_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        bitwise_and_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        bitwise_xor_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        boolean_xor_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        zend_class_entry *ce;
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
        if (IS_CONST == IS_CONST) {
                /* no function found. try a static method in class */
                ce = zend_fetch_class_by_name(Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), opline->op1.literal + 1, opline->extended_value TSRMLS_CC);
-               if (!ce) {
+               if (UNEXPECTED(ce == NULL)) {
                        zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
                }
                EX(called_scope) = ce;
@@ -3245,9 +3462,9 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_TMP_HANDLER(ZE
                        function_name_strval = Z_STRVAL_P(opline->op2.zv);
                        function_name_strlen = Z_STRLEN_P(opline->op2.zv);
                } else {
-                       function_name = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+                       function_name = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
-                       if (Z_TYPE_P(function_name) != IS_STRING) {
+                       if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                                zend_error_noreturn(E_ERROR, "Function name must be a string");
                        } else {
                                function_name_strval = Z_STRVAL_P(function_name);
@@ -3261,7 +3478,7 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_TMP_HANDLER(ZE
                        } else {
                                EX(fbc) = zend_std_get_static_method(ce, function_name_strval, function_name_strlen, ((IS_TMP_VAR == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
                        }
-                       if (!EX(fbc)) {
+                       if (UNEXPECTED(EX(fbc) == NULL)) {
                                zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name, function_name_strval);
                        }
                }
@@ -3270,11 +3487,11 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_TMP_HANDLER(ZE
                        zval_dtor(free_op2.var);
                }
        } else {
-               if(!ce->constructor) {
+               if (UNEXPECTED(ce->constructor == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot call constructor");
                }
                if (EG(This) && Z_OBJCE_P(EG(This)) != ce->constructor->common.scope && (ce->constructor->common.fn_flags & ZEND_ACC_PRIVATE)) {
-                       zend_error(E_COMPILE_ERROR, "Cannot call private %s::__construct()", ce->name);
+                       zend_error_noreturn(E_ERROR, "Cannot call private %s::__construct()", ce->name);
                }
                EX(fbc) = ce->constructor;
        }
@@ -3306,15 +3523,17 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_TMP_HANDLER(ZE
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CASE_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        int switch_expr_is_overloaded=0;
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        if (IS_CONST==IS_VAR) {
                if (EX_T(opline->op1.var).var.ptr_ptr) {
                        PZVAL_LOCK(EX_T(opline->op1.var).var.ptr);
@@ -3325,7 +3544,7 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_A
        }
        is_equal_function(&EX_T(opline->result.var).tmp_var,
                                 opline->op1.zv,
-                                _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+                                _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
        if (switch_expr_is_overloaded) {
@@ -3338,47 +3557,32 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_A
                EX_T(opline->op1.var).var.ptr_ptr = NULL;
                EX_T(opline->op1.var).var.ptr = NULL;
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_free_op free_op2;
-       zval *array_ptr = &EX_T(opline->result.var).tmp_var;
+       USE_OPLINE
+
        zval *expr_ptr;
-       zval *offset=_get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       ulong hval;
-       long index;
 
-#if 0 || IS_CONST == IS_VAR || IS_CONST == IS_CV
-       zval **expr_ptr_ptr = NULL;
+       SAVE_OPLINE();
+       if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) && opline->extended_value) {
+               zval **expr_ptr_ptr = NULL;
 
-       if (opline->extended_value) {
-               expr_ptr_ptr=NULL;
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
                expr_ptr = *expr_ptr_ptr;
+               Z_ADDREF_P(expr_ptr);
        } else {
                expr_ptr=opline->op1.zv;
-       }
-#else
-       expr_ptr=opline->op1.zv;
-#endif
-
-       if (0) { /* temporary variable */
-               zval *new_expr;
+               if (0) { /* temporary variable */
+                       zval *new_expr;
 
-               ALLOC_ZVAL(new_expr);
-               INIT_PZVAL_COPY(new_expr, expr_ptr);
-               expr_ptr = new_expr;
-       } else {
-#if 0 || IS_CONST == IS_VAR || IS_CONST == IS_CV
-               if (opline->extended_value) {
-                       SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
-                       expr_ptr = *expr_ptr_ptr;
-                       Z_ADDREF_P(expr_ptr);
-               } else
-#endif
-               if (IS_CONST == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
+                       ALLOC_ZVAL(new_expr);
+                       INIT_PZVAL_COPY(new_expr, expr_ptr);
+                       expr_ptr = new_expr;
+               } else if (IS_CONST == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
                        zval *new_expr;
 
                        ALLOC_ZVAL(new_expr);
@@ -3389,7 +3593,13 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_TMP_HANDLER(ZEND_OPC
                        Z_ADDREF_P(expr_ptr);
                }
        }
-       if (offset) {
+
+       if (IS_TMP_VAR != IS_UNUSED) {
+               zend_free_op free_op2;
+               zval *offset = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+               ulong hval;
+               long index;
+
                switch (Z_TYPE_P(offset)) {
                        case IS_DOUBLE:
                                index = zend_dval_to_lval(Z_DVAL_P(offset));
@@ -3398,7 +3608,7 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_TMP_HANDLER(ZEND_OPC
                        case IS_BOOL:
                                index = Z_LVAL_P(offset);
 num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(array_ptr), index, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_index_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), index, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_STRING:
                                if (IS_TMP_VAR == IS_CONST) {
@@ -3411,10 +3621,10 @@ num_index:
                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                        }
                                }
-                               zend_hash_quick_update(Z_ARRVAL_P(array_ptr), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_quick_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_NULL:
-                               zend_hash_update(Z_ARRVAL_P(array_ptr), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
                                break;
                        default:
                                zend_error(E_WARNING, "Illegal offset type");
@@ -3424,19 +3634,20 @@ num_index:
                }
                zval_dtor(free_op2.var);
        } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(array_ptr), &expr_ptr, sizeof(zval *), NULL);
+               zend_hash_next_index_insert(Z_ARRVAL(EX_T(opline->result.var).tmp_var), &expr_ptr, sizeof(zval *), NULL);
        }
-       if (opline->extended_value) {
+       if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) && opline->extended_value) {
 
        } else {
 
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (IS_CONST == IS_UNUSED) {
@@ -3450,260 +3661,297 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CONST_TMP_HANDLER(ZEND_OPCODE_HAN
 
 static int ZEND_FASTCALL  ZEND_ADD_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        add_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SUB_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        sub_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MUL_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        mul_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_DIV_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        div_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MOD_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        mod_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SL_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        shift_left_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SR_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        shift_right_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        concat_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        is_identical_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        is_identical_function(result,
                opline->op1.zv,
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        Z_LVAL_P(result) = !Z_LVAL_P(result);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
                opline->op1.zv,
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) == 0));
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
                opline->op1.zv,
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) != 0));
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
                opline->op1.zv,
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) < 0));
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
                opline->op1.zv,
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) <= 0));
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        bitwise_or_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        bitwise_and_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        bitwise_xor_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        boolean_xor_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        zend_class_entry *ce;
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
        if (IS_CONST == IS_CONST) {
                /* no function found. try a static method in class */
                ce = zend_fetch_class_by_name(Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), opline->op1.literal + 1, opline->extended_value TSRMLS_CC);
-               if (!ce) {
+               if (UNEXPECTED(ce == NULL)) {
                        zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
                }
                EX(called_scope) = ce;
@@ -3725,9 +3973,9 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_VAR_HANDLER(ZE
                        function_name_strval = Z_STRVAL_P(opline->op2.zv);
                        function_name_strlen = Z_STRLEN_P(opline->op2.zv);
                } else {
-                       function_name = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+                       function_name = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
-                       if (Z_TYPE_P(function_name) != IS_STRING) {
+                       if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                                zend_error_noreturn(E_ERROR, "Function name must be a string");
                        } else {
                                function_name_strval = Z_STRVAL_P(function_name);
@@ -3741,7 +3989,7 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_VAR_HANDLER(ZE
                        } else {
                                EX(fbc) = zend_std_get_static_method(ce, function_name_strval, function_name_strlen, ((IS_VAR == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
                        }
-                       if (!EX(fbc)) {
+                       if (UNEXPECTED(EX(fbc) == NULL)) {
                                zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name, function_name_strval);
                        }
                }
@@ -3750,11 +3998,11 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_VAR_HANDLER(ZE
                        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
                }
        } else {
-               if(!ce->constructor) {
+               if (UNEXPECTED(ce->constructor == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot call constructor");
                }
                if (EG(This) && Z_OBJCE_P(EG(This)) != ce->constructor->common.scope && (ce->constructor->common.fn_flags & ZEND_ACC_PRIVATE)) {
-                       zend_error(E_COMPILE_ERROR, "Cannot call private %s::__construct()", ce->name);
+                       zend_error_noreturn(E_ERROR, "Cannot call private %s::__construct()", ce->name);
                }
                EX(fbc) = ce->constructor;
        }
@@ -3786,15 +4034,17 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_VAR_HANDLER(ZE
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CASE_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        int switch_expr_is_overloaded=0;
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        if (IS_CONST==IS_VAR) {
                if (EX_T(opline->op1.var).var.ptr_ptr) {
                        PZVAL_LOCK(EX_T(opline->op1.var).var.ptr);
@@ -3805,7 +4055,7 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_A
        }
        is_equal_function(&EX_T(opline->result.var).tmp_var,
                                 opline->op1.zv,
-                                _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+                                _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        if (switch_expr_is_overloaded) {
@@ -3818,47 +4068,32 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_A
                EX_T(opline->op1.var).var.ptr_ptr = NULL;
                EX_T(opline->op1.var).var.ptr = NULL;
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_free_op free_op2;
-       zval *array_ptr = &EX_T(opline->result.var).tmp_var;
+       USE_OPLINE
+
        zval *expr_ptr;
-       zval *offset=_get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       ulong hval;
-       long index;
 
-#if 0 || IS_CONST == IS_VAR || IS_CONST == IS_CV
-       zval **expr_ptr_ptr = NULL;
+       SAVE_OPLINE();
+       if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) && opline->extended_value) {
+               zval **expr_ptr_ptr = NULL;
 
-       if (opline->extended_value) {
-               expr_ptr_ptr=NULL;
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
                expr_ptr = *expr_ptr_ptr;
+               Z_ADDREF_P(expr_ptr);
        } else {
                expr_ptr=opline->op1.zv;
-       }
-#else
-       expr_ptr=opline->op1.zv;
-#endif
-
-       if (0) { /* temporary variable */
-               zval *new_expr;
+               if (0) { /* temporary variable */
+                       zval *new_expr;
 
-               ALLOC_ZVAL(new_expr);
-               INIT_PZVAL_COPY(new_expr, expr_ptr);
-               expr_ptr = new_expr;
-       } else {
-#if 0 || IS_CONST == IS_VAR || IS_CONST == IS_CV
-               if (opline->extended_value) {
-                       SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
-                       expr_ptr = *expr_ptr_ptr;
-                       Z_ADDREF_P(expr_ptr);
-               } else
-#endif
-               if (IS_CONST == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
+                       ALLOC_ZVAL(new_expr);
+                       INIT_PZVAL_COPY(new_expr, expr_ptr);
+                       expr_ptr = new_expr;
+               } else if (IS_CONST == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
                        zval *new_expr;
 
                        ALLOC_ZVAL(new_expr);
@@ -3869,7 +4104,13 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_VAR_HANDLER(ZEND_OPC
                        Z_ADDREF_P(expr_ptr);
                }
        }
-       if (offset) {
+
+       if (IS_VAR != IS_UNUSED) {
+               zend_free_op free_op2;
+               zval *offset = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+               ulong hval;
+               long index;
+
                switch (Z_TYPE_P(offset)) {
                        case IS_DOUBLE:
                                index = zend_dval_to_lval(Z_DVAL_P(offset));
@@ -3878,7 +4119,7 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_VAR_HANDLER(ZEND_OPC
                        case IS_BOOL:
                                index = Z_LVAL_P(offset);
 num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(array_ptr), index, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_index_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), index, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_STRING:
                                if (IS_VAR == IS_CONST) {
@@ -3891,10 +4132,10 @@ num_index:
                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                        }
                                }
-                               zend_hash_quick_update(Z_ARRVAL_P(array_ptr), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_quick_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_NULL:
-                               zend_hash_update(Z_ARRVAL_P(array_ptr), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
                                break;
                        default:
                                zend_error(E_WARNING, "Illegal offset type");
@@ -3904,19 +4145,20 @@ num_index:
                }
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(array_ptr), &expr_ptr, sizeof(zval *), NULL);
+               zend_hash_next_index_insert(Z_ARRVAL(EX_T(opline->result.var).tmp_var), &expr_ptr, sizeof(zval *), NULL);
        }
-       if (opline->extended_value) {
+       if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) && opline->extended_value) {
 
        } else {
 
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (IS_CONST == IS_UNUSED) {
@@ -3930,16 +4172,17 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CONST_VAR_HANDLER(ZEND_OPCODE_HAN
 
 static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        zend_class_entry *ce;
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
        if (IS_CONST == IS_CONST) {
                /* no function found. try a static method in class */
                ce = zend_fetch_class_by_name(Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), opline->op1.literal + 1, opline->extended_value TSRMLS_CC);
-               if (!ce) {
+               if (UNEXPECTED(ce == NULL)) {
                        zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
                }
                EX(called_scope) = ce;
@@ -3963,7 +4206,7 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_UNUSED_HANDLER
                } else {
                        function_name = NULL;
 
-                       if (Z_TYPE_P(function_name) != IS_STRING) {
+                       if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                                zend_error_noreturn(E_ERROR, "Function name must be a string");
                        } else {
                                function_name_strval = Z_STRVAL_P(function_name);
@@ -3977,7 +4220,7 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_UNUSED_HANDLER
                        } else {
                                EX(fbc) = zend_std_get_static_method(ce, function_name_strval, function_name_strlen, ((IS_UNUSED == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
                        }
-                       if (!EX(fbc)) {
+                       if (UNEXPECTED(EX(fbc) == NULL)) {
                                zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name, function_name_strval);
                        }
                }
@@ -3986,11 +4229,11 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_UNUSED_HANDLER
 
                }
        } else {
-               if(!ce->constructor) {
+               if (UNEXPECTED(ce->constructor == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot call constructor");
                }
                if (EG(This) && Z_OBJCE_P(EG(This)) != ce->constructor->common.scope && (ce->constructor->common.fn_flags & ZEND_ACC_PRIVATE)) {
-                       zend_error(E_COMPILE_ERROR, "Cannot call private %s::__construct()", ce->name);
+                       zend_error_noreturn(E_ERROR, "Cannot call private %s::__construct()", ce->name);
                }
                EX(fbc) = ce->constructor;
        }
@@ -4022,47 +4265,32 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_UNUSED_HANDLER
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *array_ptr = &EX_T(opline->result.var).tmp_var;
        zval *expr_ptr;
-       zval *offset=NULL;
-       ulong hval;
-       long index;
 
-#if 0 || IS_CONST == IS_VAR || IS_CONST == IS_CV
-       zval **expr_ptr_ptr = NULL;
+       SAVE_OPLINE();
+       if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) && opline->extended_value) {
+               zval **expr_ptr_ptr = NULL;
 
-       if (opline->extended_value) {
-               expr_ptr_ptr=NULL;
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
                expr_ptr = *expr_ptr_ptr;
+               Z_ADDREF_P(expr_ptr);
        } else {
                expr_ptr=opline->op1.zv;
-       }
-#else
-       expr_ptr=opline->op1.zv;
-#endif
-
-       if (0) { /* temporary variable */
-               zval *new_expr;
+               if (0) { /* temporary variable */
+                       zval *new_expr;
 
-               ALLOC_ZVAL(new_expr);
-               INIT_PZVAL_COPY(new_expr, expr_ptr);
-               expr_ptr = new_expr;
-       } else {
-#if 0 || IS_CONST == IS_VAR || IS_CONST == IS_CV
-               if (opline->extended_value) {
-                       SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
-                       expr_ptr = *expr_ptr_ptr;
-                       Z_ADDREF_P(expr_ptr);
-               } else
-#endif
-               if (IS_CONST == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
+                       ALLOC_ZVAL(new_expr);
+                       INIT_PZVAL_COPY(new_expr, expr_ptr);
+                       expr_ptr = new_expr;
+               } else if (IS_CONST == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
                        zval *new_expr;
 
                        ALLOC_ZVAL(new_expr);
@@ -4073,7 +4301,13 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_UNUSED_HANDLER(ZEND_
                        Z_ADDREF_P(expr_ptr);
                }
        }
-       if (offset) {
+
+       if (IS_UNUSED != IS_UNUSED) {
+
+               zval *offset = NULL;
+               ulong hval;
+               long index;
+
                switch (Z_TYPE_P(offset)) {
                        case IS_DOUBLE:
                                index = zend_dval_to_lval(Z_DVAL_P(offset));
@@ -4082,7 +4316,7 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_UNUSED_HANDLER(ZEND_
                        case IS_BOOL:
                                index = Z_LVAL_P(offset);
 num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(array_ptr), index, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_index_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), index, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_STRING:
                                if (IS_UNUSED == IS_CONST) {
@@ -4095,10 +4329,10 @@ num_index:
                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                        }
                                }
-                               zend_hash_quick_update(Z_ARRVAL_P(array_ptr), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_quick_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_NULL:
-                               zend_hash_update(Z_ARRVAL_P(array_ptr), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
                                break;
                        default:
                                zend_error(E_WARNING, "Illegal offset type");
@@ -4108,19 +4342,20 @@ num_index:
                }
 
        } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(array_ptr), &expr_ptr, sizeof(zval *), NULL);
+               zend_hash_next_index_insert(Z_ARRVAL(EX_T(opline->result.var).tmp_var), &expr_ptr, sizeof(zval *), NULL);
        }
-       if (opline->extended_value) {
+       if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) && opline->extended_value) {
 
        } else {
 
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (IS_CONST == IS_UNUSED) {
@@ -4134,275 +4369,315 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_
 
 static int ZEND_FASTCALL  ZEND_DECLARE_LAMBDA_FUNCTION_SPEC_CONST_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_function *op_array;
 
-       if (zend_hash_quick_find(EG(function_table), Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), Z_HASH_P(opline->op1.zv), (void *) &op_array) == FAILURE ||
-           op_array->type != ZEND_USER_FUNCTION) {
+       SAVE_OPLINE();
+
+       if (UNEXPECTED(zend_hash_quick_find(EG(function_table), Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), Z_HASH_P(opline->op1.zv), (void *) &op_array) == FAILURE) ||
+           UNEXPECTED(op_array->type != ZEND_USER_FUNCTION)) {
                zend_error_noreturn(E_ERROR, "Base lambda function for closure not found");
        }
 
        zend_create_closure(&EX_T(opline->result.var).tmp_var, op_array, EG(scope), EG(This) TSRMLS_CC);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        add_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SUB_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        sub_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MUL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        mul_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_DIV_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        div_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MOD_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        mod_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        shift_left_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SR_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        shift_right_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        concat_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        is_identical_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        is_identical_function(result,
                opline->op1.zv,
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        Z_LVAL_P(result) = !Z_LVAL_P(result);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
                opline->op1.zv,
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) == 0));
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
                opline->op1.zv,
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) != 0));
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
                opline->op1.zv,
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) < 0));
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
                opline->op1.zv,
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) <= 0));
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        bitwise_or_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        bitwise_and_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        bitwise_xor_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        boolean_xor_function(&EX_T(opline->result.var).tmp_var,
                opline->op1.zv,
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        zend_class_entry *ce;
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
        if (IS_CONST == IS_CONST) {
                /* no function found. try a static method in class */
                ce = zend_fetch_class_by_name(Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), opline->op1.literal + 1, opline->extended_value TSRMLS_CC);
-               if (!ce) {
+               if (UNEXPECTED(ce == NULL)) {
                        zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
                }
                EX(called_scope) = ce;
@@ -4424,9 +4699,9 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_CV_HANDLER(ZEN
                        function_name_strval = Z_STRVAL_P(opline->op2.zv);
                        function_name_strlen = Z_STRLEN_P(opline->op2.zv);
                } else {
-                       function_name = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+                       function_name = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
 
-                       if (Z_TYPE_P(function_name) != IS_STRING) {
+                       if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                                zend_error_noreturn(E_ERROR, "Function name must be a string");
                        } else {
                                function_name_strval = Z_STRVAL_P(function_name);
@@ -4440,7 +4715,7 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_CV_HANDLER(ZEN
                        } else {
                                EX(fbc) = zend_std_get_static_method(ce, function_name_strval, function_name_strlen, ((IS_CV == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
                        }
-                       if (!EX(fbc)) {
+                       if (UNEXPECTED(EX(fbc) == NULL)) {
                                zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name, function_name_strval);
                        }
                }
@@ -4449,11 +4724,11 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_CV_HANDLER(ZEN
 
                }
        } else {
-               if(!ce->constructor) {
+               if (UNEXPECTED(ce->constructor == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot call constructor");
                }
                if (EG(This) && Z_OBJCE_P(EG(This)) != ce->constructor->common.scope && (ce->constructor->common.fn_flags & ZEND_ACC_PRIVATE)) {
-                       zend_error(E_COMPILE_ERROR, "Cannot call private %s::__construct()", ce->name);
+                       zend_error_noreturn(E_ERROR, "Cannot call private %s::__construct()", ce->name);
                }
                EX(fbc) = ce->constructor;
        }
@@ -4485,15 +4760,57 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_CONST_CV_HANDLER(ZEN
                }
        }
 
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_CATCH_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_class_entry *ce, *catch_ce;
+
+       SAVE_OPLINE();
+       /* Check whether an exception has been thrown, if not, jump over code */
+       zend_exception_restore(TSRMLS_C);
+       if (EG(exception) == NULL) {
+               ZEND_VM_SET_OPCODE(&EX(op_array)->opcodes[opline->extended_value]);
+               ZEND_VM_CONTINUE(); /* CHECK_ME */
+       }
+       catch_ce = zend_fetch_class_by_name(Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), opline->op1.literal + 1, ZEND_FETCH_CLASS_NO_AUTOLOAD TSRMLS_CC);
+       ce = Z_OBJCE_P(EG(exception));
+       if (ce != catch_ce) {
+               if (!instanceof_function(ce, catch_ce TSRMLS_CC)) {
+                       if (opline->result.num) {
+                               zend_throw_exception_internal(NULL TSRMLS_CC);
+                               HANDLE_EXCEPTION();
+                       }
+                       ZEND_VM_SET_OPCODE(&EX(op_array)->opcodes[opline->extended_value]);
+                       ZEND_VM_CONTINUE(); /* CHECK_ME */
+               }
+       }
+
+       if (!EG(active_symbol_table)) {
+               if (EX_CV(opline->op2.var)) {
+                       zval_ptr_dtor(EX_CV(opline->op2.var));
+               }
+               EX_CV(opline->op2.var) = (zval**)EX_CVs() + (EX(op_array)->last_var + opline->op2.var);
+               *EX_CV(opline->op2.var) = EG(exception);
+       } else {
+               zend_compiled_variable *cv = &CV_DEF_OF(opline->op2.var);
+               zend_hash_quick_update(EG(active_symbol_table), cv->name, cv->name_len+1, cv->hash_value,
+                   &EG(exception), sizeof(zval *), (void**)&EX_CV(opline->op2.var));
+       }
+       EG(exception) = NULL;
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CASE_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        int switch_expr_is_overloaded=0;
 
 
+       SAVE_OPLINE();
        if (IS_CONST==IS_VAR) {
                if (EX_T(opline->op1.var).var.ptr_ptr) {
                        PZVAL_LOCK(EX_T(opline->op1.var).var.ptr);
@@ -4504,7 +4821,7 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_AR
        }
        is_equal_function(&EX_T(opline->result.var).tmp_var,
                                 opline->op1.zv,
-                                _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+                                _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
        if (switch_expr_is_overloaded) {
                /* We only free op1 if this is a string offset,
@@ -4516,47 +4833,32 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_AR
                EX_T(opline->op1.var).var.ptr_ptr = NULL;
                EX_T(opline->op1.var).var.ptr = NULL;
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *array_ptr = &EX_T(opline->result.var).tmp_var;
        zval *expr_ptr;
-       zval *offset=_get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-       ulong hval;
-       long index;
 
-#if 0 || IS_CONST == IS_VAR || IS_CONST == IS_CV
-       zval **expr_ptr_ptr = NULL;
+       SAVE_OPLINE();
+       if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) && opline->extended_value) {
+               zval **expr_ptr_ptr = NULL;
 
-       if (opline->extended_value) {
-               expr_ptr_ptr=NULL;
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
                expr_ptr = *expr_ptr_ptr;
+               Z_ADDREF_P(expr_ptr);
        } else {
                expr_ptr=opline->op1.zv;
-       }
-#else
-       expr_ptr=opline->op1.zv;
-#endif
-
-       if (0) { /* temporary variable */
-               zval *new_expr;
+               if (0) { /* temporary variable */
+                       zval *new_expr;
 
-               ALLOC_ZVAL(new_expr);
-               INIT_PZVAL_COPY(new_expr, expr_ptr);
-               expr_ptr = new_expr;
-       } else {
-#if 0 || IS_CONST == IS_VAR || IS_CONST == IS_CV
-               if (opline->extended_value) {
-                       SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
-                       expr_ptr = *expr_ptr_ptr;
-                       Z_ADDREF_P(expr_ptr);
-               } else
-#endif
-               if (IS_CONST == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
+                       ALLOC_ZVAL(new_expr);
+                       INIT_PZVAL_COPY(new_expr, expr_ptr);
+                       expr_ptr = new_expr;
+               } else if (IS_CONST == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
                        zval *new_expr;
 
                        ALLOC_ZVAL(new_expr);
@@ -4567,7 +4869,13 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_CV_HANDLER(ZEND_OPCO
                        Z_ADDREF_P(expr_ptr);
                }
        }
-       if (offset) {
+
+       if (IS_CV != IS_UNUSED) {
+
+               zval *offset = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+               ulong hval;
+               long index;
+
                switch (Z_TYPE_P(offset)) {
                        case IS_DOUBLE:
                                index = zend_dval_to_lval(Z_DVAL_P(offset));
@@ -4576,7 +4884,7 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CONST_CV_HANDLER(ZEND_OPCO
                        case IS_BOOL:
                                index = Z_LVAL_P(offset);
 num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(array_ptr), index, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_index_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), index, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_STRING:
                                if (IS_CV == IS_CONST) {
@@ -4589,10 +4897,10 @@ num_index:
                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                        }
                                }
-                               zend_hash_quick_update(Z_ARRVAL_P(array_ptr), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_quick_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_NULL:
-                               zend_hash_update(Z_ARRVAL_P(array_ptr), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
                                break;
                        default:
                                zend_error(E_WARNING, "Illegal offset type");
@@ -4602,19 +4910,20 @@ num_index:
                }
 
        } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(array_ptr), &expr_ptr, sizeof(zval *), NULL);
+               zend_hash_next_index_insert(Z_ARRVAL(EX_T(opline->result.var).tmp_var), &expr_ptr, sizeof(zval *), NULL);
        }
-       if (opline->extended_value) {
+       if ((IS_CONST == IS_VAR || IS_CONST == IS_CV) && opline->extended_value) {
 
        } else {
 
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (IS_CONST == IS_UNUSED) {
@@ -4628,35 +4937,43 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CONST_CV_HANDLER(ZEND_OPCODE_HAND
 
 static int ZEND_FASTCALL  ZEND_BW_NOT_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        bitwise_not_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BOOL_NOT_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        boolean_not_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ECHO_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval z_copy;
-       zval *z = _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *z;
+
+       SAVE_OPLINE();
+       z = _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
        if (IS_TMP_VAR != IS_CONST &&
-           Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get_method != NULL &&
+           UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) &&
+           Z_OBJ_HT_P(z)->get_method != NULL &&
                zend_std_cast_object_tostring(z, &z_copy, IS_STRING TSRMLS_CC) == SUCCESS) {
                zend_print_variable(&z_copy);
                zval_dtor(&z_copy);
@@ -4665,31 +4982,33 @@ static int ZEND_FASTCALL  ZEND_ECHO_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
        }
 
        zval_dtor(free_op1.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_PRINT_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-
-       Z_LVAL(EX_T(opline->result.var).tmp_var) = 1;
-       Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_LONG;
+       USE_OPLINE
 
+       ZVAL_LONG(&EX_T(opline->result.var).tmp_var, 1);
        return ZEND_ECHO_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
 static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_TMP(int type, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *varname = _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *varname;
        zval **retval;
        zval tmp_varname;
        HashTable *target_symbol_table;
        ulong hash_value;
 
-       if (IS_TMP_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-               tmp_varname = *varname;
+       SAVE_OPLINE();
+       varname = _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_TMP_VAR != IS_CONST && UNEXPECTED(Z_TYPE_P(varname) != IS_STRING)) {
+               ZVAL_COPY_VALUE(&tmp_varname, varname);
                zval_copy_ctor(&tmp_varname);
                convert_to_string(&tmp_varname);
                varname = &tmp_varname;
@@ -4702,6 +5021,7 @@ static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_TMP(int type, ZEND_O
                target_symbol_table = zend_get_target_symbol_table(opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
 /*
                if (!target_symbol_table) {
+                       CHECK_EXCEPTION();
                        ZEND_VM_NEXT_OPCODE();
                }
 */
@@ -4725,12 +5045,9 @@ static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_TMP(int type, ZEND_O
                                case BP_VAR_RW:
                                        zend_error(E_NOTICE,"Undefined variable: %s", Z_STRVAL_P(varname));
                                        /* break missing intentionally */
-                               case BP_VAR_W: {
-                                               zval *new_zval = &EG(uninitialized_zval);
-
-                                               Z_ADDREF_P(new_zval);
-                                               zend_hash_quick_update(target_symbol_table, Z_STRVAL_P(varname), Z_STRLEN_P(varname)+1, hash_value, &new_zval, sizeof(zval *), (void **) &retval);
-                                       }
+                               case BP_VAR_W:
+                                       Z_ADDREF_P(&EG(uninitialized_zval));
+                                       zend_hash_quick_update(target_symbol_table, Z_STRVAL_P(varname), Z_STRLEN_P(varname)+1, hash_value, &EG(uninitialized_zval_ptr), sizeof(zval *), (void **) &retval);
                                        break;
                                EMPTY_SWITCH_DEFAULT_CASE()
                        }
@@ -4757,7 +5074,7 @@ static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_TMP(int type, ZEND_O
 
 
        if (IS_TMP_VAR != IS_CONST && varname == &tmp_varname) {
-               zval_dtor(varname);
+               zval_dtor(&tmp_varname);
        }
        if (RETURN_VALUE_USED(opline)) {
                if (opline->extended_value & ZEND_FETCH_MAKE_REF) {
@@ -4767,25 +5084,25 @@ static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_TMP(int type, ZEND_O
                switch (type) {
                        case BP_VAR_R:
                        case BP_VAR_IS:
-                               AI_SET_PTR(EX_T(opline->result.var).var, *retval);
+                               AI_SET_PTR(&EX_T(opline->result.var), *retval);
                                break;
                        case BP_VAR_UNSET: {
                                zend_free_op free_res;
 
-                               EX_T(opline->result.var).var.ptr_ptr = retval;
-                               PZVAL_UNLOCK(*EX_T(opline->result.var).var.ptr_ptr, &free_res);
-                               if (EX_T(opline->result.var).var.ptr_ptr != &EG(uninitialized_zval_ptr)) {
-                                       SEPARATE_ZVAL_IF_NOT_REF(EX_T(opline->result.var).var.ptr_ptr);
+                               PZVAL_UNLOCK(*retval, &free_res);
+                               if (retval != &EG(uninitialized_zval_ptr)) {
+                                       SEPARATE_ZVAL_IF_NOT_REF(retval);
                                }
-                               PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
+                               PZVAL_LOCK(*retval);
                                FREE_OP_VAR_PTR(free_res);
-                               break;
+                       }
+                       /* break missing intentionally */
                        default:
                                EX_T(opline->result.var).var.ptr_ptr = retval;
                                break;
-                       }
                }
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -4806,7 +5123,9 @@ static int ZEND_FASTCALL  ZEND_FETCH_RW_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARG
 
 static int ZEND_FASTCALL  ZEND_FETCH_FUNC_ARG_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_var_address_helper_SPEC_TMP(ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (EX(opline)->extended_value & ZEND_FETCH_ARG_MASK))?BP_VAR_W:BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       USE_OPLINE
+
+       return zend_fetch_var_address_helper_SPEC_TMP(ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))?BP_VAR_W:BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_UNSET_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
@@ -4821,18 +5140,21 @@ static int ZEND_FASTCALL  ZEND_FETCH_IS_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARG
 
 static int ZEND_FASTCALL  ZEND_JMPZ_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *val = _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *val;
        int ret;
 
-       if (IS_TMP_VAR == IS_TMP_VAR && Z_TYPE_P(val) == IS_BOOL) {
+       SAVE_OPLINE();
+       val = _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_TMP_VAR == IS_TMP_VAR && EXPECTED(Z_TYPE_P(val) == IS_BOOL)) {
                ret = Z_LVAL_P(val);
        } else {
                ret = i_zend_is_true(val);
                zval_dtor(free_op1.var);
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       ZEND_VM_CONTINUE();
+                       HANDLE_EXCEPTION();
                }
        }
        if (!ret) {
@@ -4848,18 +5170,21 @@ static int ZEND_FASTCALL  ZEND_JMPZ_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 
 static int ZEND_FASTCALL  ZEND_JMPNZ_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *val = _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *val;
        int ret;
 
-       if (IS_TMP_VAR == IS_TMP_VAR && Z_TYPE_P(val) == IS_BOOL) {
+       SAVE_OPLINE();
+       val = _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_TMP_VAR == IS_TMP_VAR && EXPECTED(Z_TYPE_P(val) == IS_BOOL)) {
                ret = Z_LVAL_P(val);
        } else {
                ret = i_zend_is_true(val);
                zval_dtor(free_op1.var);
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       ZEND_VM_CONTINUE();
+                       HANDLE_EXCEPTION();
                }
        }
        if (ret) {
@@ -4875,18 +5200,21 @@ static int ZEND_FASTCALL  ZEND_JMPNZ_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 
 static int ZEND_FASTCALL  ZEND_JMPZNZ_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *val = _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *val;
        int retval;
 
-       if (IS_TMP_VAR == IS_TMP_VAR && Z_TYPE_P(val) == IS_BOOL) {
+       SAVE_OPLINE();
+       val = _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_TMP_VAR == IS_TMP_VAR && EXPECTED(Z_TYPE_P(val) == IS_BOOL)) {
                retval = Z_LVAL_P(val);
        } else {
                retval = i_zend_is_true(val);
                zval_dtor(free_op1.var);
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       ZEND_VM_CONTINUE();
+                       HANDLE_EXCEPTION();
                }
        }
        if (EXPECTED(retval != 0)) {
@@ -4906,18 +5234,21 @@ static int ZEND_FASTCALL  ZEND_JMPZNZ_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 
 static int ZEND_FASTCALL  ZEND_JMPZ_EX_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *val = _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *val;
        int retval;
 
-       if (IS_TMP_VAR == IS_TMP_VAR && Z_TYPE_P(val) == IS_BOOL) {
+       SAVE_OPLINE();
+       val = _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_TMP_VAR == IS_TMP_VAR && EXPECTED(Z_TYPE_P(val) == IS_BOOL)) {
                retval = Z_LVAL_P(val);
        } else {
                retval = i_zend_is_true(val);
                zval_dtor(free_op1.var);
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       ZEND_VM_CONTINUE();
+                       HANDLE_EXCEPTION();
                }
        }
        Z_LVAL(EX_T(opline->result.var).tmp_var) = retval;
@@ -4934,18 +5265,21 @@ static int ZEND_FASTCALL  ZEND_JMPZ_EX_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS
 
 static int ZEND_FASTCALL  ZEND_JMPNZ_EX_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *val = _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *val;
        int retval;
 
-       if (IS_TMP_VAR == IS_TMP_VAR && Z_TYPE_P(val) == IS_BOOL) {
+       SAVE_OPLINE();
+       val = _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_TMP_VAR == IS_TMP_VAR && EXPECTED(Z_TYPE_P(val) == IS_BOOL)) {
                retval = Z_LVAL_P(val);
        } else {
                retval = i_zend_is_true(val);
                zval_dtor(free_op1.var);
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       ZEND_VM_CONTINUE();
+                       HANDLE_EXCEPTION();
                }
        }
        Z_LVAL(EX_T(opline->result.var).tmp_var) = retval;
@@ -4962,18 +5296,23 @@ static int ZEND_FASTCALL  ZEND_JMPNZ_EX_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARG
 
 static int ZEND_FASTCALL  ZEND_FREE_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zendi_zval_dtor(EX_T(EX(opline)->op1.var).tmp_var);
+       USE_OPLINE
+
+       SAVE_OPLINE();
+       zendi_zval_dtor(EX_T(opline->op1.var).tmp_var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_RETURN_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *retval_ptr;
        zval **retval_ptr_ptr;
        zend_free_op free_op1;
 
-       if (EG(active_op_array)->return_reference == ZEND_RETURN_REF) {
+       SAVE_OPLINE();
+       if (UNEXPECTED(EG(active_op_array)->return_reference == ZEND_RETURN_REF)) {
 
                if (IS_TMP_VAR == IS_CONST || IS_TMP_VAR == IS_TMP_VAR) {
                        /* Not supposed to happen, but we'll allow it */
@@ -4983,7 +5322,7 @@ static int ZEND_FASTCALL  ZEND_RETURN_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 
                retval_ptr_ptr = NULL;
 
-               if (IS_TMP_VAR == IS_VAR && !retval_ptr_ptr) {
+               if (IS_TMP_VAR == IS_VAR && UNEXPECTED(retval_ptr_ptr == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot return string offsets by reference");
                }
 
@@ -5005,10 +5344,12 @@ static int ZEND_FASTCALL  ZEND_RETURN_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 
                        (*EG(return_value_ptr_ptr)) = (*retval_ptr_ptr);
                }
+
+               return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else {
 return_by_value:
 
-               retval_ptr = _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+               retval_ptr = _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
                if (!EG(return_value_ptr_ptr)) {
                        if (IS_TMP_VAR == IS_TMP_VAR) {
@@ -5035,21 +5376,22 @@ return_by_value:
                        INIT_PZVAL_COPY(ret, retval_ptr);
                        *EG(return_value_ptr_ptr) = ret;
                }
-       }
 
-       return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
 }
 
 static int ZEND_FASTCALL  ZEND_THROW_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *value;
        zval *exception;
        zend_free_op free_op1;
 
-       value = _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       SAVE_OPLINE();
+       value = _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (IS_TMP_VAR == IS_CONST || Z_TYPE_P(value) != IS_OBJECT) {
+       if (IS_TMP_VAR == IS_CONST || UNEXPECTED(Z_TYPE_P(value) != IS_OBJECT)) {
                zend_error_noreturn(E_ERROR, "Can only throw objects");
        }
        zend_exception_save(TSRMLS_C);
@@ -5063,12 +5405,14 @@ static int ZEND_FASTCALL  ZEND_THROW_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
        zend_throw_exception_object(exception TSRMLS_CC);
        zend_exception_restore(TSRMLS_C);
 
-       ZEND_VM_NEXT_OPCODE();
+       HANDLE_EXCEPTION();
 }
 
 static int ZEND_FASTCALL  ZEND_SEND_VAL_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       SAVE_OPLINE();
        if (opline->extended_value==ZEND_DO_FCALL_BY_NAME
                && ARG_MUST_BE_SENT_BY_REF(EX(fbc), opline->op2.opline_num)) {
                        zend_error_noreturn(E_ERROR, "Cannot pass parameter %d by reference", opline->op2.opline_num);
@@ -5078,7 +5422,7 @@ static int ZEND_FASTCALL  ZEND_SEND_VAL_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARG
                zval *value;
                zend_free_op free_op1;
 
-               value = _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+               value = _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
                ALLOC_ZVAL(valptr);
                INIT_PZVAL_COPY(valptr, value);
@@ -5088,41 +5432,47 @@ static int ZEND_FASTCALL  ZEND_SEND_VAL_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARG
                zend_vm_stack_push(valptr TSRMLS_CC);
 
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BOOL_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
+       zval *retval = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        /* PHP 3.0 returned "" for false and 1 for true, here we use 0 and 1 for now */
-       Z_LVAL(EX_T(opline->result.var).tmp_var) = i_zend_is_true(_get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC));
-       Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
+       ZVAL_BOOL(retval, i_zend_is_true(_get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC)));
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CLONE_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *obj = _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *obj;
        zend_class_entry *ce;
        zend_function *clone;
        zend_object_clone_obj_t clone_call;
 
+       SAVE_OPLINE();
+       obj = _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
        if (IS_TMP_VAR == IS_CONST ||
-           (IS_TMP_VAR == IS_VAR && !obj) ||
-           Z_TYPE_P(obj) != IS_OBJECT) {
+           (IS_TMP_VAR == IS_VAR && UNEXPECTED(obj == NULL)) ||
+           UNEXPECTED(Z_TYPE_P(obj) != IS_OBJECT)) {
                zend_error_noreturn(E_ERROR, "__clone method called on non-object");
        }
 
        ce = Z_OBJCE_P(obj);
        clone = ce ? ce->clone : NULL;
        clone_call =  Z_OBJ_HT_P(obj)->clone_obj;
-       if (!clone_call) {
+       if (UNEXPECTED(clone_call == NULL)) {
                if (ce) {
                        zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object of class %s", ce->name);
                } else {
@@ -5134,42 +5484,49 @@ static int ZEND_FASTCALL  ZEND_CLONE_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
                if (clone->op_array.fn_flags & ZEND_ACC_PRIVATE) {
                        /* Ensure that if we're calling a private function, we're allowed to do so.
                         */
-                       if (ce != EG(scope)) {
+                       if (UNEXPECTED(ce != EG(scope))) {
                                zend_error_noreturn(E_ERROR, "Call to private %s::__clone() from context '%s'", ce->name, EG(scope) ? EG(scope)->name : "");
                        }
                } else if ((clone->common.fn_flags & ZEND_ACC_PROTECTED)) {
                        /* Ensure that if we're calling a protected function, we're allowed to do so.
                         */
-                       if (!zend_check_protected(clone->common.scope, EG(scope))) {
+                       if (UNEXPECTED(!zend_check_protected(clone->common.scope, EG(scope)))) {
                                zend_error_noreturn(E_ERROR, "Call to protected %s::__clone() from context '%s'", ce->name, EG(scope) ? EG(scope)->name : "");
                        }
                }
        }
 
-       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-       if (!EG(exception)) {
-               ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-               Z_OBJVAL_P(EX_T(opline->result.var).var.ptr) = clone_call(obj TSRMLS_CC);
-               Z_TYPE_P(EX_T(opline->result.var).var.ptr) = IS_OBJECT;
-               Z_SET_REFCOUNT_P(EX_T(opline->result.var).var.ptr, 1);
-               Z_SET_ISREF_P(EX_T(opline->result.var).var.ptr);
-               if (!RETURN_VALUE_USED(opline) || EG(exception)) {
-                       zval_ptr_dtor(&EX_T(opline->result.var).var.ptr);
+       if (EXPECTED(EG(exception) == NULL)) {
+               zval *retval;
+
+               ALLOC_ZVAL(retval);
+               Z_OBJVAL_P(retval) = clone_call(obj TSRMLS_CC);
+               Z_TYPE_P(retval) = IS_OBJECT;
+               Z_SET_REFCOUNT_P(retval, 1);
+               Z_SET_ISREF_P(retval);
+               if (!RETURN_VALUE_USED(opline) || UNEXPECTED(EG(exception) != NULL)) {
+                       zval_ptr_dtor(&retval);
+               } else {
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CAST_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *expr = _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *expr;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
+       expr = _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
        if (opline->extended_value != IS_STRING) {
-               *result = *expr;
+               ZVAL_COPY_VALUE(result, expr);
                if (!1) {
                        zendi_zval_copy_ctor(*result);
                }
@@ -5193,12 +5550,12 @@ static int ZEND_FASTCALL  ZEND_CAST_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 
                        zend_make_printable_zval(expr, &var_copy, &use_copy);
                        if (use_copy) {
-                               *result = var_copy;
+                               ZVAL_COPY_VALUE(result, &var_copy);
                                if (1) {
                                        zval_dtor(free_op1.var);
                                }
                        } else {
-                               *result = *expr;
+                               ZVAL_COPY_VALUE(result, expr);
                                if (!1) {
                                        zendi_zval_copy_ctor(*result);
                                }
@@ -5213,28 +5570,29 @@ static int ZEND_FASTCALL  ZEND_CAST_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
                        break;
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INCLUDE_OR_EVAL_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_op_array *new_op_array=NULL;
-       int return_value_used;
        zend_free_op free_op1;
-       zval *inc_filename = _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *inc_filename;
        zval tmp_inc_filename;
        zend_bool failure_retval=0;
 
+       SAVE_OPLINE();
+       inc_filename = _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
        if (inc_filename->type!=IS_STRING) {
-               tmp_inc_filename = *inc_filename;
+               ZVAL_COPY_VALUE(&tmp_inc_filename, inc_filename);
                zval_copy_ctor(&tmp_inc_filename);
                convert_to_string(&tmp_inc_filename);
                inc_filename = &tmp_inc_filename;
        }
 
-       return_value_used = RETURN_VALUE_USED(opline);
-
        switch (opline->extended_value) {
                case ZEND_INCLUDE_ONCE:
                case ZEND_REQUIRE_ONCE: {
@@ -5292,12 +5650,18 @@ static int ZEND_FASTCALL  ZEND_INCLUDE_OR_EVAL_SPEC_TMP_HANDLER(ZEND_OPCODE_HAND
                zval_dtor(&tmp_inc_filename);
        }
        zval_dtor(free_op1.var);
-       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-       if (new_op_array && !EG(exception)) {
+       if (UNEXPECTED(EG(exception) != NULL)) {
+               HANDLE_EXCEPTION();
+       } else if (EXPECTED(new_op_array != NULL)) {
                EX(original_return_value) = EG(return_value_ptr_ptr);
-               EG(return_value_ptr_ptr) = return_value_used ? EX_T(opline->result.var).var.ptr_ptr : NULL;
                EG(active_op_array) = new_op_array;
-               EX_T(opline->result.var).var.ptr = NULL;
+               if (RETURN_VALUE_USED(opline)) {
+                       EX_T(opline->result.var).var.ptr = NULL;
+                       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
+                       EG(return_value_ptr_ptr) = EX_T(opline->result.var).var.ptr_ptr;
+               } else {
+                       EG(return_value_ptr_ptr) = NULL;
+               }
 
                EX(current_object) = EX(object);
 
@@ -5308,8 +5672,7 @@ static int ZEND_FASTCALL  ZEND_INCLUDE_OR_EVAL_SPEC_TMP_HANDLER(ZEND_OPCODE_HAND
                        zend_rebuild_symbol_table(TSRMLS_C);
                }
 
-               if (zend_execute == execute) {
-                       EX(call_opline) = opline;
+               if (EXPECTED(zend_execute == execute)) {
                        ZEND_VM_ENTER();
                } else {
                        zend_execute(new_op_array TSRMLS_CC);
@@ -5318,75 +5681,62 @@ static int ZEND_FASTCALL  ZEND_INCLUDE_OR_EVAL_SPEC_TMP_HANDLER(ZEND_OPCODE_HAND
                EX(function_state).function = (zend_function *) EX(op_array);
                EX(object) = EX(current_object);
 
-               if (return_value_used) {
-                       if (!EX_T(opline->result.var).var.ptr) { /* there was no return statement */
-                               ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                               INIT_PZVAL(EX_T(opline->result.var).var.ptr);
-                               Z_LVAL_P(EX_T(opline->result.var).var.ptr) = 1;
-                               Z_TYPE_P(EX_T(opline->result.var).var.ptr) = IS_BOOL;
-                       }
-               }
-
                EG(opline_ptr) = &EX(opline);
                EG(active_op_array) = EX(op_array);
                EG(return_value_ptr_ptr) = EX(original_return_value);
                destroy_op_array(new_op_array TSRMLS_CC);
                efree(new_op_array);
-               if (EG(exception)) {
+               if (UNEXPECTED(EG(exception) != NULL)) {
                        zend_throw_exception_internal(NULL TSRMLS_CC);
+                       HANDLE_EXCEPTION();
+               } else if (RETURN_VALUE_USED(opline)) {
+                       if (!EX_T(opline->result.var).var.ptr) { /* there was no return statement */
+                               zval *retval;
+
+                               ALLOC_ZVAL(retval);
+                               ZVAL_BOOL(retval, 1);
+                               INIT_PZVAL(retval);
+                               EX_T(opline->result.var).var.ptr = retval;
+                       }
                }
-       } else {
-               if (return_value_used) {
-                       ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                       INIT_ZVAL(*EX_T(opline->result.var).var.ptr);
-                       Z_LVAL_P(EX_T(opline->result.var).var.ptr) = failure_retval;
-                       Z_TYPE_P(EX_T(opline->result.var).var.ptr) = IS_BOOL;
-               }
+
+       } else if (RETURN_VALUE_USED(opline)) {
+               zval *retval;
+
+               ALLOC_ZVAL(retval);
+               ZVAL_BOOL(retval, failure_retval);
+               INIT_PZVAL(retval);
+               AI_SET_PTR(&EX_T(opline->result.var), retval);
        }
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval tmp, *varname;
        HashTable *target_symbol_table;
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        if (IS_TMP_VAR == IS_CV && (opline->extended_value & ZEND_QUICK_SET)) {
                if (EG(active_symbol_table)) {
-                       zend_execute_data *ex = EX(prev_execute_data);
                        zend_compiled_variable *cv = &CV_DEF_OF(opline->op1.var);
 
-                       if (zend_hash_quick_del(EG(active_symbol_table), cv->name, cv->name_len+1, cv->hash_value) == SUCCESS) {
-                               while (ex && ex->symbol_table == EG(active_symbol_table)) {
-                                       int i;
-
-                                       if (ex->op_array) {
-                                               for (i = 0; i < ex->op_array->last_var; i++) {
-                                                       if (ex->op_array->vars[i].hash_value == cv->hash_value &&
-                                                               ex->op_array->vars[i].name_len == cv->name_len &&
-                                                               !memcmp(ex->op_array->vars[i].name, cv->name, cv->name_len)) {
-                                                               ex->CVs[i] = NULL;
-                                                               break;
-                                                       }
-                                               }
-                                       }
-                                       ex = ex->prev_execute_data;
-                               }
-                       }
-                       EX(CVs)[opline->op1.var] = NULL;
-               } else if (EX(CVs)[opline->op1.var]) {
-                       zval_ptr_dtor(EX(CVs)[opline->op1.var]);
-                       EX(CVs)[opline->op1.var] = NULL;
+                       zend_delete_variable(EX(prev_execute_data), EG(active_symbol_table),  cv->name, cv->name_len+1, cv->hash_value TSRMLS_CC);
+                       EX_CV(opline->op1.var) = NULL;
+               } else if (EX_CV(opline->op1.var)) {
+                       zval_ptr_dtor(EX_CV(opline->op1.var));
+                       EX_CV(opline->op1.var) = NULL;
                }
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
-       varname = _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       varname = _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
        if (IS_TMP_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-               tmp = *varname;
+               ZVAL_COPY_VALUE(&tmp, varname);
                zval_copy_ctor(&tmp);
                convert_to_string(&tmp);
                varname = &tmp;
@@ -5400,39 +5750,22 @@ static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_AR
                ulong hash_value = zend_inline_hash_func(varname->value.str.val, varname->value.str.len+1);
 
                target_symbol_table = zend_get_target_symbol_table(opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-               if (zend_hash_quick_del(target_symbol_table, varname->value.str.val, varname->value.str.len+1, hash_value) == SUCCESS) {
-                       zend_execute_data *ex = execute_data;
-
-                       do {
-                               int i;
-
-                               if (ex->op_array) {
-                                       for (i = 0; i < ex->op_array->last_var; i++) {
-                                               if (ex->op_array->vars[i].hash_value == hash_value &&
-                                                       ex->op_array->vars[i].name_len == varname->value.str.len &&
-                                                       !memcmp(ex->op_array->vars[i].name, varname->value.str.val, varname->value.str.len)) {
-                                                       ex->CVs[i] = NULL;
-                                                       break;
-                                               }
-                                       }
-                               }
-                               ex = ex->prev_execute_data;
-                       } while (ex && ex->symbol_table == target_symbol_table);
-               }
+               zend_delete_variable(execute_data, target_symbol_table, varname->value.str.val, varname->value.str.len+1, hash_value TSRMLS_CC);
        }
 
-       if (varname == &tmp) {
+       if (IS_TMP_VAR != IS_CONST && varname == &tmp) {
                zval_dtor(&tmp);
        } else if (IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) {
                zval_ptr_dtor(&varname);
        }
        zval_dtor(free_op1.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *array_ptr, **array_ptr_ptr;
        HashTable *fe_ht;
@@ -5440,10 +5773,13 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARG
        zend_class_entry *ce = NULL;
        zend_bool is_empty = 0;
 
+       SAVE_OPLINE();
+
        if (opline->extended_value & ZEND_FE_RESET_VARIABLE) {
                array_ptr_ptr = NULL;
                if (array_ptr_ptr == NULL || array_ptr_ptr == &EG(uninitialized_zval_ptr)) {
-                       ALLOC_INIT_ZVAL(array_ptr);
+                       MAKE_STD_ZVAL(array_ptr);
+                       ZVAL_NULL(array_ptr);
                } else if (Z_TYPE_PP(array_ptr_ptr) == IS_OBJECT) {
                        if(Z_OBJ_HT_PP(array_ptr_ptr)->get_class_entry == NULL) {
                                zend_error(E_WARNING, "foreach() cannot iterate over objects without PHP class");
@@ -5467,7 +5803,7 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARG
                        Z_ADDREF_P(array_ptr);
                }
        } else {
-               array_ptr = _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+               array_ptr = _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
                if (1) { /* IS_TMP_VAR */
                        zval *tmp;
 
@@ -5503,7 +5839,7 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARG
        if (ce && ce->get_iterator) {
                iter = ce->get_iterator(ce, array_ptr, opline->extended_value & ZEND_FE_RESET_REFERENCE TSRMLS_CC);
 
-               if (iter && !EG(exception)) {
+               if (iter && EXPECTED(EG(exception) == NULL)) {
                        array_ptr = zend_iterator_wrap(iter TSRMLS_CC);
                } else {
                        if (opline->extended_value & ZEND_FE_RESET_VARIABLE) {
@@ -5515,18 +5851,18 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARG
                                zend_throw_exception_ex(NULL, 0 TSRMLS_CC, "Object of type %s did not create an Iterator", ce->name);
                        }
                        zend_throw_exception_internal(NULL TSRMLS_CC);
-                       ZEND_VM_NEXT_OPCODE();
+                       HANDLE_EXCEPTION();
                }
        }
 
-       AI_SET_PTR(EX_T(opline->result.var).var, array_ptr);
        PZVAL_LOCK(array_ptr);
+       AI_SET_PTR(&EX_T(opline->result.var), array_ptr);
 
        if (iter) {
                iter->index = 0;
                if (iter->funcs->rewind) {
                        iter->funcs->rewind(iter TSRMLS_CC);
-                       if (EG(exception)) {
+                       if (UNEXPECTED(EG(exception) != NULL)) {
                                Z_DELREF_P(array_ptr);
                                zval_ptr_dtor(&array_ptr);
                                if (opline->extended_value & ZEND_FE_RESET_VARIABLE) {
@@ -5534,11 +5870,11 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARG
                                } else {
 
                                }
-                               ZEND_VM_NEXT_OPCODE();
+                               HANDLE_EXCEPTION();
                        }
                }
                is_empty = iter->funcs->valid(iter TSRMLS_CC) != SUCCESS;
-               if (EG(exception)) {
+               if (UNEXPECTED(EG(exception) != NULL)) {
                        Z_DELREF_P(array_ptr);
                        zval_ptr_dtor(&array_ptr);
                        if (opline->extended_value & ZEND_FE_RESET_VARIABLE) {
@@ -5546,7 +5882,7 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARG
                        } else {
 
                        }
-                       ZEND_VM_NEXT_OPCODE();
+                       HANDLE_EXCEPTION();
                }
                iter->index = -1; /* will be set to 0 before using next handler */
        } else if ((fe_ht = HASH_OF(array_ptr)) != NULL) {
@@ -5583,19 +5919,21 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARG
        if (is_empty) {
                ZEND_VM_JMP(EX(op_array)->opcodes+opline->op2.opline_num);
        } else {
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 }
 
 static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval **value;
        zend_bool isset = 1;
 
+       SAVE_OPLINE();
        if (IS_TMP_VAR == IS_CV && (opline->extended_value & ZEND_QUICK_SET)) {
-               if (EX(CVs)[opline->op1.var]) {
-                       value = EX(CVs)[opline->op1.var];
+               if (EX_CV(opline->op1.var)) {
+                       value = EX_CV(opline->op1.var);
                } else if (EG(active_symbol_table)) {
                        zend_compiled_variable *cv = &CV_DEF_OF(opline->op1.var);
 
@@ -5608,10 +5946,10 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_TMP_HANDLER(ZEND_OPCODE_HA
        } else {
                HashTable *target_symbol_table;
                zend_free_op free_op1;
-               zval tmp, *varname = _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+               zval tmp, *varname = _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
                if (IS_TMP_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-                       tmp = *varname;
+                       ZVAL_COPY_VALUE(&tmp, varname);
                        zval_copy_ctor(&tmp);
                        convert_to_string(&tmp);
                        varname = &tmp;
@@ -5629,38 +5967,39 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_TMP_HANDLER(ZEND_OPCODE_HA
                        }
                }
 
-               if (varname == &tmp) {
+               if (IS_TMP_VAR != IS_CONST && varname == &tmp) {
                        zval_dtor(&tmp);
                }
                zval_dtor(free_op1.var);
        }
 
-       Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
-
        if (opline->extended_value & ZEND_ISSET) {
-               if (isset && Z_TYPE_PP(value) == IS_NULL) {
-                       Z_LVAL(EX_T(opline->result.var).tmp_var) = 0;
+               if (isset && Z_TYPE_PP(value) != IS_NULL) {
+                       ZVAL_BOOL(&EX_T(opline->result.var).tmp_var, 1);
                } else {
-                       Z_LVAL(EX_T(opline->result.var).tmp_var) = isset;
+                       ZVAL_BOOL(&EX_T(opline->result.var).tmp_var, 0);
                }
        } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
                if (!isset || !i_zend_is_true(*value)) {
-                       Z_LVAL(EX_T(opline->result.var).tmp_var) = 1;
+                       ZVAL_BOOL(&EX_T(opline->result.var).tmp_var, 1);
                } else {
-                       Z_LVAL(EX_T(opline->result.var).tmp_var) = 0;
+                       ZVAL_BOOL(&EX_T(opline->result.var).tmp_var, 0);
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_EXIT_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
 #if 0 || (IS_TMP_VAR != IS_UNUSED)
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       SAVE_OPLINE();
        if (IS_TMP_VAR != IS_UNUSED) {
                zend_free_op free_op1;
-               zval *ptr = _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+               zval *ptr = _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
                if (Z_TYPE_P(ptr) == IS_LONG) {
                        EG(exit_status) = Z_LVAL_P(ptr);
@@ -5671,14 +6010,15 @@ static int ZEND_FASTCALL  ZEND_EXIT_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
        }
 #endif
        zend_bailout();
-       ZEND_VM_NEXT_OPCODE();
+       ZEND_VM_NEXT_OPCODE(); /* Never reached */
 }
 
 static int ZEND_FASTCALL  ZEND_END_SILENCE_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval restored_error_reporting;
 
+       SAVE_OPLINE();
        if (!EG(error_reporting) && Z_LVAL(EX_T(opline->op1.var).tmp_var) != 0) {
                Z_TYPE(restored_error_reporting) = IS_LONG;
                Z_LVAL(restored_error_reporting) = Z_LVAL(EX_T(opline->op1.var).tmp_var);
@@ -5689,17 +6029,21 @@ static int ZEND_FASTCALL  ZEND_END_SILENCE_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_
        if (EX(old_error_reporting) == &EX_T(opline->op1.var).tmp_var) {
                EX(old_error_reporting) = NULL;
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_JMP_SET_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *value = _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *value;
+
+       SAVE_OPLINE();
+       value = _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
        if (i_zend_is_true(value)) {
-               EX_T(opline->result.var).tmp_var = *value;
+               ZVAL_COPY_VALUE(&EX_T(opline->result.var).tmp_var, value);
                zendi_zval_copy_ctor(EX_T(opline->result.var).tmp_var);
                zval_dtor(free_op1.var);
 #if DEBUG_ZEND>=2
@@ -5709,30 +6053,38 @@ static int ZEND_FASTCALL  ZEND_JMP_SET_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS
        }
 
        zval_dtor(free_op1.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_QM_ASSIGN_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *value = _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *value;
 
-       EX_T(opline->result.var).tmp_var = *value;
+       SAVE_OPLINE();
+       value = _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       ZVAL_COPY_VALUE(&EX_T(opline->result.var).tmp_var, value);
        if (!1) {
                zval_copy_ctor(&EX_T(opline->result.var).tmp_var);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INSTANCEOF_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *expr = _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *expr;
        zend_bool result;
 
+       SAVE_OPLINE();
+       expr = _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
        if (Z_TYPE_P(expr) == IS_OBJECT && Z_OBJ_HT_P(expr)->get_class_entry) {
                result = instanceof_function(Z_OBJCE_P(expr), EX_T(opline->op2.var).class_entry TSRMLS_CC);
        } else {
@@ -5740,280 +6092,323 @@ static int ZEND_FASTCALL  ZEND_INSTANCEOF_SPEC_TMP_HANDLER(ZEND_OPCODE_HANDLER_A
        }
        ZVAL_BOOL(&EX_T(opline->result.var).tmp_var, result);
        zval_dtor(free_op1.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        add_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SUB_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        sub_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MUL_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        mul_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_DIV_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        div_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MOD_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        mod_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SL_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        shift_left_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SR_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        shift_right_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        concat_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        is_identical_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        is_identical_function(result,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        Z_LVAL_P(result) = !Z_LVAL_P(result);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) == 0));
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) != 0));
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) < 0));
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) <= 0));
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        bitwise_or_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        bitwise_and_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        bitwise_xor_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        boolean_xor_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_TMP_VAR_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *container = _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *container;
 
-       if (Z_TYPE_P(container) != IS_ARRAY) {
+       SAVE_OPLINE();
+       container = _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_ARRAY)) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
        } else {
 
-               zval *dim = opline->op2.zv;
+               zval *value = *zend_fetch_dimension_address_inner(Z_ARRVAL_P(container), opline->op2.zv, IS_CONST, BP_VAR_R TSRMLS_CC);
 
-               AI_SET_PTR(EX_T(opline->result.var).var, *zend_fetch_dimension_address_inner(Z_ARRVAL_P(container), dim, IS_CONST, BP_VAR_R TSRMLS_CC));
-               SELECTIVE_PZVAL_LOCK(EX_T(opline->result.var).var.ptr, opline);
+               SELECTIVE_PZVAL_LOCK(value, opline);
+               AI_SET_PTR(&EX_T(opline->result.var), value);
 
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_CHAR_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *str = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
+
        if (IS_TMP_VAR == IS_UNUSED) {
                /* Initialize for erealloc in add_char_to_string */
                Z_STRVAL_P(str) = NULL;
@@ -6026,14 +6421,17 @@ static int ZEND_FASTCALL  ZEND_ADD_CHAR_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDL
        add_char_to_string(str, str, opline->op2.zv);
 
        /* FREE_OP is missing intentionally here - we're always working on the same temporary variable */
+       /*CHECK_EXCEPTION();*/
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_STRING_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *str = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
+
        if (IS_TMP_VAR == IS_UNUSED) {
                /* Initialize for erealloc in add_string_to_string */
                Z_STRVAL_P(str) = NULL;
@@ -6046,38 +6444,42 @@ static int ZEND_FASTCALL  ZEND_ADD_STRING_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HAN
        add_string_to_string(str, str, opline->op2.zv);
 
        /* FREE_OP is missing intentionally here - we're always working on the same temporary variable */
+       /*CHECK_EXCEPTION();*/
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        char *function_name_strval;
        int function_name_strlen;
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
        function_name = opline->op2.zv;
 
-       if (Z_TYPE_P(function_name)!=IS_STRING) {
+       if (IS_CONST != IS_CONST &&
+           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                zend_error_noreturn(E_ERROR, "Method name must be a string");
        }
 
        function_name_strval = Z_STRVAL_P(function_name);
        function_name_strlen = Z_STRLEN_P(function_name);
 
-       EX(object) = _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       EX(object) = _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (EX(object) && Z_TYPE_P(EX(object)) == IS_OBJECT) {
-               if (Z_OBJ_HT_P(EX(object))->get_method == NULL) {
+       if (EXPECTED(EX(object) != NULL) &&
+           EXPECTED(Z_TYPE_P(EX(object)) == IS_OBJECT)) {
+               if (UNEXPECTED(Z_OBJ_HT_P(EX(object))->get_method == NULL)) {
                        zend_error_noreturn(E_ERROR, "Object does not support method calls");
                }
 
                /* First, locate the function. */
                EX(fbc) = Z_OBJ_HT_P(EX(object))->get_method(&EX(object), function_name_strval, function_name_strlen, ((IS_CONST == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
-               if (!EX(fbc)) {
+               if (UNEXPECTED(EX(fbc) == NULL)) {
                        zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", Z_OBJ_CLASS_NAME_P(EX(object)), function_name_strval);
                }
 
@@ -6101,15 +6503,17 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_TMP_CONST_HANDLER(ZEND_OPCO
        }
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CASE_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        int switch_expr_is_overloaded=0;
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        if (IS_TMP_VAR==IS_VAR) {
                if (EX_T(opline->op1.var).var.ptr_ptr) {
                        PZVAL_LOCK(EX_T(opline->op1.var).var.ptr);
@@ -6119,7 +6523,7 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_A
                }
        }
        is_equal_function(&EX_T(opline->result.var).tmp_var,
-                                _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+                                _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                                 opline->op2.zv TSRMLS_CC);
 
        if (switch_expr_is_overloaded) {
@@ -6132,47 +6536,32 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_A
                EX_T(opline->op1.var).var.ptr_ptr = NULL;
                EX_T(opline->op1.var).var.ptr = NULL;
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *array_ptr = &EX_T(opline->result.var).tmp_var;
        zval *expr_ptr;
-       zval *offset=opline->op2.zv;
-       ulong hval;
-       long index;
 
-#if 0 || IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV
-       zval **expr_ptr_ptr = NULL;
+       SAVE_OPLINE();
+       if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && opline->extended_value) {
+               zval **expr_ptr_ptr = NULL;
 
-       if (opline->extended_value) {
-               expr_ptr_ptr=NULL;
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
                expr_ptr = *expr_ptr_ptr;
+               Z_ADDREF_P(expr_ptr);
        } else {
-               expr_ptr=_get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       }
-#else
-       expr_ptr=_get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-#endif
-
-       if (1) { /* temporary variable */
-               zval *new_expr;
+               expr_ptr=_get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+               if (1) { /* temporary variable */
+                       zval *new_expr;
 
-               ALLOC_ZVAL(new_expr);
-               INIT_PZVAL_COPY(new_expr, expr_ptr);
-               expr_ptr = new_expr;
-       } else {
-#if 0 || IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV
-               if (opline->extended_value) {
-                       SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
-                       expr_ptr = *expr_ptr_ptr;
-                       Z_ADDREF_P(expr_ptr);
-               } else
-#endif
-               if (IS_TMP_VAR == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
+                       ALLOC_ZVAL(new_expr);
+                       INIT_PZVAL_COPY(new_expr, expr_ptr);
+                       expr_ptr = new_expr;
+               } else if (IS_TMP_VAR == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
                        zval *new_expr;
 
                        ALLOC_ZVAL(new_expr);
@@ -6183,7 +6572,13 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_CONST_HANDLER(ZEND_OPC
                        Z_ADDREF_P(expr_ptr);
                }
        }
-       if (offset) {
+
+       if (IS_CONST != IS_UNUSED) {
+
+               zval *offset = opline->op2.zv;
+               ulong hval;
+               long index;
+
                switch (Z_TYPE_P(offset)) {
                        case IS_DOUBLE:
                                index = zend_dval_to_lval(Z_DVAL_P(offset));
@@ -6192,7 +6587,7 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_CONST_HANDLER(ZEND_OPC
                        case IS_BOOL:
                                index = Z_LVAL_P(offset);
 num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(array_ptr), index, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_index_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), index, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_STRING:
                                if (IS_CONST == IS_CONST) {
@@ -6205,10 +6600,10 @@ num_index:
                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                        }
                                }
-                               zend_hash_quick_update(Z_ARRVAL_P(array_ptr), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_quick_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_NULL:
-                               zend_hash_update(Z_ARRVAL_P(array_ptr), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
                                break;
                        default:
                                zend_error(E_WARNING, "Illegal offset type");
@@ -6218,19 +6613,20 @@ num_index:
                }
 
        } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(array_ptr), &expr_ptr, sizeof(zval *), NULL);
+               zend_hash_next_index_insert(Z_ARRVAL(EX_T(opline->result.var).tmp_var), &expr_ptr, sizeof(zval *), NULL);
        }
-       if (opline->extended_value) {
+       if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && opline->extended_value) {
 
        } else {
 
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (IS_TMP_VAR == IS_UNUSED) {
@@ -6244,257 +6640,296 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_TMP_CONST_HANDLER(ZEND_OPCODE_HAN
 
 static int ZEND_FASTCALL  ZEND_ADD_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        add_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SUB_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        sub_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MUL_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        mul_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_DIV_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        div_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MOD_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        mod_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SL_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        shift_left_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SR_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        shift_right_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        concat_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        is_identical_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        is_identical_function(result,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        Z_LVAL_P(result) = !Z_LVAL_P(result);
        zval_dtor(free_op1.var);
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) == 0));
        zval_dtor(free_op1.var);
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) != 0));
        zval_dtor(free_op1.var);
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) < 0));
        zval_dtor(free_op1.var);
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) <= 0));
        zval_dtor(free_op1.var);
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        bitwise_or_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        bitwise_and_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        bitwise_xor_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        boolean_xor_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_VAR_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval *str = &EX_T(opline->result.var).tmp_var;
-       zval *var = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval *var;
        zval var_copy;
        int use_copy = 0;
 
+       SAVE_OPLINE();
+       var = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
        if (IS_TMP_VAR == IS_UNUSED) {
                /* Initialize for erealloc in add_string_to_string */
                Z_STRVAL_P(str) = NULL;
@@ -6524,38 +6959,42 @@ static int ZEND_FASTCALL  ZEND_ADD_VAR_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_
         */
        zval_dtor(free_op2.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        char *function_name_strval;
        int function_name_strlen;
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
-       function_name = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       function_name = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
-       if (Z_TYPE_P(function_name)!=IS_STRING) {
+       if (IS_TMP_VAR != IS_CONST &&
+           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                zend_error_noreturn(E_ERROR, "Method name must be a string");
        }
 
        function_name_strval = Z_STRVAL_P(function_name);
        function_name_strlen = Z_STRLEN_P(function_name);
 
-       EX(object) = _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       EX(object) = _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (EX(object) && Z_TYPE_P(EX(object)) == IS_OBJECT) {
-               if (Z_OBJ_HT_P(EX(object))->get_method == NULL) {
+       if (EXPECTED(EX(object) != NULL) &&
+           EXPECTED(Z_TYPE_P(EX(object)) == IS_OBJECT)) {
+               if (UNEXPECTED(Z_OBJ_HT_P(EX(object))->get_method == NULL)) {
                        zend_error_noreturn(E_ERROR, "Object does not support method calls");
                }
 
                /* First, locate the function. */
                EX(fbc) = Z_OBJ_HT_P(EX(object))->get_method(&EX(object), function_name_strval, function_name_strlen, ((IS_TMP_VAR == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
-               if (!EX(fbc)) {
+               if (UNEXPECTED(EX(fbc) == NULL)) {
                        zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", Z_OBJ_CLASS_NAME_P(EX(object)), function_name_strval);
                }
 
@@ -6580,15 +7019,17 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE
 
        zval_dtor(free_op2.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CASE_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        int switch_expr_is_overloaded=0;
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        if (IS_TMP_VAR==IS_VAR) {
                if (EX_T(opline->op1.var).var.ptr_ptr) {
                        PZVAL_LOCK(EX_T(opline->op1.var).var.ptr);
@@ -6598,8 +7039,8 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARG
                }
        }
        is_equal_function(&EX_T(opline->result.var).tmp_var,
-                                _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-                                _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+                                _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+                                _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
        if (switch_expr_is_overloaded) {
@@ -6612,47 +7053,32 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARG
                EX_T(opline->op1.var).var.ptr_ptr = NULL;
                EX_T(opline->op1.var).var.ptr = NULL;
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_free_op free_op1, free_op2;
-       zval *array_ptr = &EX_T(opline->result.var).tmp_var;
+       USE_OPLINE
+       zend_free_op free_op1;
        zval *expr_ptr;
-       zval *offset=_get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       ulong hval;
-       long index;
 
-#if 0 || IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV
-       zval **expr_ptr_ptr = NULL;
+       SAVE_OPLINE();
+       if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && opline->extended_value) {
+               zval **expr_ptr_ptr = NULL;
 
-       if (opline->extended_value) {
-               expr_ptr_ptr=NULL;
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
                expr_ptr = *expr_ptr_ptr;
+               Z_ADDREF_P(expr_ptr);
        } else {
-               expr_ptr=_get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       }
-#else
-       expr_ptr=_get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-#endif
-
-       if (1) { /* temporary variable */
-               zval *new_expr;
+               expr_ptr=_get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+               if (1) { /* temporary variable */
+                       zval *new_expr;
 
-               ALLOC_ZVAL(new_expr);
-               INIT_PZVAL_COPY(new_expr, expr_ptr);
-               expr_ptr = new_expr;
-       } else {
-#if 0 || IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV
-               if (opline->extended_value) {
-                       SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
-                       expr_ptr = *expr_ptr_ptr;
-                       Z_ADDREF_P(expr_ptr);
-               } else
-#endif
-               if (IS_TMP_VAR == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
+                       ALLOC_ZVAL(new_expr);
+                       INIT_PZVAL_COPY(new_expr, expr_ptr);
+                       expr_ptr = new_expr;
+               } else if (IS_TMP_VAR == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
                        zval *new_expr;
 
                        ALLOC_ZVAL(new_expr);
@@ -6663,7 +7089,13 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_TMP_HANDLER(ZEND_OPCOD
                        Z_ADDREF_P(expr_ptr);
                }
        }
-       if (offset) {
+
+       if (IS_TMP_VAR != IS_UNUSED) {
+               zend_free_op free_op2;
+               zval *offset = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+               ulong hval;
+               long index;
+
                switch (Z_TYPE_P(offset)) {
                        case IS_DOUBLE:
                                index = zend_dval_to_lval(Z_DVAL_P(offset));
@@ -6672,7 +7104,7 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_TMP_HANDLER(ZEND_OPCOD
                        case IS_BOOL:
                                index = Z_LVAL_P(offset);
 num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(array_ptr), index, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_index_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), index, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_STRING:
                                if (IS_TMP_VAR == IS_CONST) {
@@ -6685,10 +7117,10 @@ num_index:
                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                        }
                                }
-                               zend_hash_quick_update(Z_ARRVAL_P(array_ptr), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_quick_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_NULL:
-                               zend_hash_update(Z_ARRVAL_P(array_ptr), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
                                break;
                        default:
                                zend_error(E_WARNING, "Illegal offset type");
@@ -6698,19 +7130,20 @@ num_index:
                }
                zval_dtor(free_op2.var);
        } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(array_ptr), &expr_ptr, sizeof(zval *), NULL);
+               zend_hash_next_index_insert(Z_ARRVAL(EX_T(opline->result.var).tmp_var), &expr_ptr, sizeof(zval *), NULL);
        }
-       if (opline->extended_value) {
+       if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && opline->extended_value) {
 
        } else {
 
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (IS_TMP_VAR == IS_UNUSED) {
@@ -6724,257 +7157,296 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_TMP_TMP_HANDLER(ZEND_OPCODE_HANDL
 
 static int ZEND_FASTCALL  ZEND_ADD_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        add_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SUB_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        sub_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MUL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        mul_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_DIV_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        div_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MOD_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        mod_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        shift_left_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        shift_right_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        concat_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        is_identical_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        is_identical_function(result,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        Z_LVAL_P(result) = !Z_LVAL_P(result);
        zval_dtor(free_op1.var);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) == 0));
        zval_dtor(free_op1.var);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) != 0));
        zval_dtor(free_op1.var);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) < 0));
        zval_dtor(free_op1.var);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) <= 0));
        zval_dtor(free_op1.var);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        bitwise_or_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        bitwise_and_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        bitwise_xor_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        boolean_xor_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_VAR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval *str = &EX_T(opline->result.var).tmp_var;
-       zval *var = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval *var;
        zval var_copy;
        int use_copy = 0;
 
+       SAVE_OPLINE();
+       var = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
        if (IS_TMP_VAR == IS_UNUSED) {
                /* Initialize for erealloc in add_string_to_string */
                Z_STRVAL_P(str) = NULL;
@@ -7004,38 +7476,42 @@ static int ZEND_FASTCALL  ZEND_ADD_VAR_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_
         */
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        char *function_name_strval;
        int function_name_strlen;
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
-       function_name = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       function_name = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
-       if (Z_TYPE_P(function_name)!=IS_STRING) {
+       if (IS_VAR != IS_CONST &&
+           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                zend_error_noreturn(E_ERROR, "Method name must be a string");
        }
 
        function_name_strval = Z_STRVAL_P(function_name);
        function_name_strlen = Z_STRLEN_P(function_name);
 
-       EX(object) = _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       EX(object) = _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (EX(object) && Z_TYPE_P(EX(object)) == IS_OBJECT) {
-               if (Z_OBJ_HT_P(EX(object))->get_method == NULL) {
+       if (EXPECTED(EX(object) != NULL) &&
+           EXPECTED(Z_TYPE_P(EX(object)) == IS_OBJECT)) {
+               if (UNEXPECTED(Z_OBJ_HT_P(EX(object))->get_method == NULL)) {
                        zend_error_noreturn(E_ERROR, "Object does not support method calls");
                }
 
                /* First, locate the function. */
                EX(fbc) = Z_OBJ_HT_P(EX(object))->get_method(&EX(object), function_name_strval, function_name_strlen, ((IS_VAR == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
-               if (!EX(fbc)) {
+               if (UNEXPECTED(EX(fbc) == NULL)) {
                        zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", Z_OBJ_CLASS_NAME_P(EX(object)), function_name_strval);
                }
 
@@ -7060,15 +7536,17 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CASE_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        int switch_expr_is_overloaded=0;
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        if (IS_TMP_VAR==IS_VAR) {
                if (EX_T(opline->op1.var).var.ptr_ptr) {
                        PZVAL_LOCK(EX_T(opline->op1.var).var.ptr);
@@ -7078,8 +7556,8 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
                }
        }
        is_equal_function(&EX_T(opline->result.var).tmp_var,
-                                _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-                                _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+                                _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+                                _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        if (switch_expr_is_overloaded) {
@@ -7092,47 +7570,32 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
                EX_T(opline->op1.var).var.ptr_ptr = NULL;
                EX_T(opline->op1.var).var.ptr = NULL;
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_free_op free_op1, free_op2;
-       zval *array_ptr = &EX_T(opline->result.var).tmp_var;
+       USE_OPLINE
+       zend_free_op free_op1;
        zval *expr_ptr;
-       zval *offset=_get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       ulong hval;
-       long index;
 
-#if 0 || IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV
-       zval **expr_ptr_ptr = NULL;
+       SAVE_OPLINE();
+       if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && opline->extended_value) {
+               zval **expr_ptr_ptr = NULL;
 
-       if (opline->extended_value) {
-               expr_ptr_ptr=NULL;
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
                expr_ptr = *expr_ptr_ptr;
+               Z_ADDREF_P(expr_ptr);
        } else {
-               expr_ptr=_get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       }
-#else
-       expr_ptr=_get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-#endif
-
-       if (1) { /* temporary variable */
-               zval *new_expr;
+               expr_ptr=_get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+               if (1) { /* temporary variable */
+                       zval *new_expr;
 
-               ALLOC_ZVAL(new_expr);
-               INIT_PZVAL_COPY(new_expr, expr_ptr);
-               expr_ptr = new_expr;
-       } else {
-#if 0 || IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV
-               if (opline->extended_value) {
-                       SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
-                       expr_ptr = *expr_ptr_ptr;
-                       Z_ADDREF_P(expr_ptr);
-               } else
-#endif
-               if (IS_TMP_VAR == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
+                       ALLOC_ZVAL(new_expr);
+                       INIT_PZVAL_COPY(new_expr, expr_ptr);
+                       expr_ptr = new_expr;
+               } else if (IS_TMP_VAR == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
                        zval *new_expr;
 
                        ALLOC_ZVAL(new_expr);
@@ -7143,7 +7606,13 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_VAR_HANDLER(ZEND_OPCOD
                        Z_ADDREF_P(expr_ptr);
                }
        }
-       if (offset) {
+
+       if (IS_VAR != IS_UNUSED) {
+               zend_free_op free_op2;
+               zval *offset = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+               ulong hval;
+               long index;
+
                switch (Z_TYPE_P(offset)) {
                        case IS_DOUBLE:
                                index = zend_dval_to_lval(Z_DVAL_P(offset));
@@ -7152,7 +7621,7 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_VAR_HANDLER(ZEND_OPCOD
                        case IS_BOOL:
                                index = Z_LVAL_P(offset);
 num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(array_ptr), index, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_index_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), index, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_STRING:
                                if (IS_VAR == IS_CONST) {
@@ -7165,10 +7634,10 @@ num_index:
                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                        }
                                }
-                               zend_hash_quick_update(Z_ARRVAL_P(array_ptr), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_quick_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_NULL:
-                               zend_hash_update(Z_ARRVAL_P(array_ptr), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
                                break;
                        default:
                                zend_error(E_WARNING, "Illegal offset type");
@@ -7178,19 +7647,20 @@ num_index:
                }
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(array_ptr), &expr_ptr, sizeof(zval *), NULL);
+               zend_hash_next_index_insert(Z_ARRVAL(EX_T(opline->result.var).tmp_var), &expr_ptr, sizeof(zval *), NULL);
        }
-       if (opline->extended_value) {
+       if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && opline->extended_value) {
 
        } else {
 
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (IS_TMP_VAR == IS_UNUSED) {
@@ -7204,42 +7674,26 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_TMP_VAR_HANDLER(ZEND_OPCODE_HANDL
 
 static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *array_ptr = &EX_T(opline->result.var).tmp_var;
        zval *expr_ptr;
-       zval *offset=NULL;
-       ulong hval;
-       long index;
 
-#if 0 || IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV
-       zval **expr_ptr_ptr = NULL;
+       SAVE_OPLINE();
+       if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && opline->extended_value) {
+               zval **expr_ptr_ptr = NULL;
 
-       if (opline->extended_value) {
-               expr_ptr_ptr=NULL;
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
                expr_ptr = *expr_ptr_ptr;
+               Z_ADDREF_P(expr_ptr);
        } else {
-               expr_ptr=_get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       }
-#else
-       expr_ptr=_get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-#endif
-
-       if (1) { /* temporary variable */
-               zval *new_expr;
+               expr_ptr=_get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+               if (1) { /* temporary variable */
+                       zval *new_expr;
 
-               ALLOC_ZVAL(new_expr);
-               INIT_PZVAL_COPY(new_expr, expr_ptr);
-               expr_ptr = new_expr;
-       } else {
-#if 0 || IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV
-               if (opline->extended_value) {
-                       SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
-                       expr_ptr = *expr_ptr_ptr;
-                       Z_ADDREF_P(expr_ptr);
-               } else
-#endif
-               if (IS_TMP_VAR == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
+                       ALLOC_ZVAL(new_expr);
+                       INIT_PZVAL_COPY(new_expr, expr_ptr);
+                       expr_ptr = new_expr;
+               } else if (IS_TMP_VAR == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
                        zval *new_expr;
 
                        ALLOC_ZVAL(new_expr);
@@ -7250,7 +7704,13 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_UNUSED_HANDLER(ZEND_OP
                        Z_ADDREF_P(expr_ptr);
                }
        }
-       if (offset) {
+
+       if (IS_UNUSED != IS_UNUSED) {
+
+               zval *offset = NULL;
+               ulong hval;
+               long index;
+
                switch (Z_TYPE_P(offset)) {
                        case IS_DOUBLE:
                                index = zend_dval_to_lval(Z_DVAL_P(offset));
@@ -7259,7 +7719,7 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_UNUSED_HANDLER(ZEND_OP
                        case IS_BOOL:
                                index = Z_LVAL_P(offset);
 num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(array_ptr), index, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_index_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), index, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_STRING:
                                if (IS_UNUSED == IS_CONST) {
@@ -7272,10 +7732,10 @@ num_index:
                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                        }
                                }
-                               zend_hash_quick_update(Z_ARRVAL_P(array_ptr), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_quick_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_NULL:
-                               zend_hash_update(Z_ARRVAL_P(array_ptr), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
                                break;
                        default:
                                zend_error(E_WARNING, "Illegal offset type");
@@ -7285,19 +7745,20 @@ num_index:
                }
 
        } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(array_ptr), &expr_ptr, sizeof(zval *), NULL);
+               zend_hash_next_index_insert(Z_ARRVAL(EX_T(opline->result.var).tmp_var), &expr_ptr, sizeof(zval *), NULL);
        }
-       if (opline->extended_value) {
+       if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && opline->extended_value) {
 
        } else {
 
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (IS_TMP_VAR == IS_UNUSED) {
@@ -7311,257 +7772,296 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_TMP_UNUSED_HANDLER(ZEND_OPCODE_HA
 
 static int ZEND_FASTCALL  ZEND_ADD_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        add_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SUB_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        sub_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MUL_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        mul_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_DIV_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        div_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MOD_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        mod_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SL_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        shift_left_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        shift_right_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        concat_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        is_identical_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        is_identical_function(result,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        Z_LVAL_P(result) = !Z_LVAL_P(result);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) == 0));
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) != 0));
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) < 0));
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) <= 0));
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        bitwise_or_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        bitwise_and_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        bitwise_xor_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        boolean_xor_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        zval_dtor(free_op1.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_VAR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *str = &EX_T(opline->result.var).tmp_var;
-       zval *var = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       zval *var;
        zval var_copy;
        int use_copy = 0;
 
+       SAVE_OPLINE();
+       var = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+
        if (IS_TMP_VAR == IS_UNUSED) {
                /* Initialize for erealloc in add_string_to_string */
                Z_STRVAL_P(str) = NULL;
@@ -7590,38 +8090,42 @@ static int ZEND_FASTCALL  ZEND_ADD_VAR_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_A
         * string offsets or overloaded objects
         */
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        char *function_name_strval;
        int function_name_strlen;
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
-       function_name = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       function_name = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
 
-       if (Z_TYPE_P(function_name)!=IS_STRING) {
+       if (IS_CV != IS_CONST &&
+           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                zend_error_noreturn(E_ERROR, "Method name must be a string");
        }
 
        function_name_strval = Z_STRVAL_P(function_name);
        function_name_strlen = Z_STRLEN_P(function_name);
 
-       EX(object) = _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       EX(object) = _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (EX(object) && Z_TYPE_P(EX(object)) == IS_OBJECT) {
-               if (Z_OBJ_HT_P(EX(object))->get_method == NULL) {
+       if (EXPECTED(EX(object) != NULL) &&
+           EXPECTED(Z_TYPE_P(EX(object)) == IS_OBJECT)) {
+               if (UNEXPECTED(Z_OBJ_HT_P(EX(object))->get_method == NULL)) {
                        zend_error_noreturn(E_ERROR, "Object does not support method calls");
                }
 
                /* First, locate the function. */
                EX(fbc) = Z_OBJ_HT_P(EX(object))->get_method(&EX(object), function_name_strval, function_name_strlen, ((IS_CV == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
-               if (!EX(fbc)) {
+               if (UNEXPECTED(EX(fbc) == NULL)) {
                        zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", Z_OBJ_CLASS_NAME_P(EX(object)), function_name_strval);
                }
 
@@ -7645,15 +8149,17 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_
        }
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CASE_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        int switch_expr_is_overloaded=0;
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        if (IS_TMP_VAR==IS_VAR) {
                if (EX_T(opline->op1.var).var.ptr_ptr) {
                        PZVAL_LOCK(EX_T(opline->op1.var).var.ptr);
@@ -7663,8 +8169,8 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS
                }
        }
        is_equal_function(&EX_T(opline->result.var).tmp_var,
-                                _get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-                                _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+                                _get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+                                _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
        if (switch_expr_is_overloaded) {
                /* We only free op1 if this is a string offset,
@@ -7676,47 +8182,32 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS
                EX_T(opline->op1.var).var.ptr_ptr = NULL;
                EX_T(opline->op1.var).var.ptr = NULL;
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *array_ptr = &EX_T(opline->result.var).tmp_var;
        zval *expr_ptr;
-       zval *offset=_get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-       ulong hval;
-       long index;
 
-#if 0 || IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV
-       zval **expr_ptr_ptr = NULL;
+       SAVE_OPLINE();
+       if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && opline->extended_value) {
+               zval **expr_ptr_ptr = NULL;
 
-       if (opline->extended_value) {
-               expr_ptr_ptr=NULL;
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
                expr_ptr = *expr_ptr_ptr;
+               Z_ADDREF_P(expr_ptr);
        } else {
-               expr_ptr=_get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       }
-#else
-       expr_ptr=_get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-#endif
-
-       if (1) { /* temporary variable */
-               zval *new_expr;
+               expr_ptr=_get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+               if (1) { /* temporary variable */
+                       zval *new_expr;
 
-               ALLOC_ZVAL(new_expr);
-               INIT_PZVAL_COPY(new_expr, expr_ptr);
-               expr_ptr = new_expr;
-       } else {
-#if 0 || IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV
-               if (opline->extended_value) {
-                       SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
-                       expr_ptr = *expr_ptr_ptr;
-                       Z_ADDREF_P(expr_ptr);
-               } else
-#endif
-               if (IS_TMP_VAR == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
+                       ALLOC_ZVAL(new_expr);
+                       INIT_PZVAL_COPY(new_expr, expr_ptr);
+                       expr_ptr = new_expr;
+               } else if (IS_TMP_VAR == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
                        zval *new_expr;
 
                        ALLOC_ZVAL(new_expr);
@@ -7727,7 +8218,13 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_CV_HANDLER(ZEND_OPCODE
                        Z_ADDREF_P(expr_ptr);
                }
        }
-       if (offset) {
+
+       if (IS_CV != IS_UNUSED) {
+
+               zval *offset = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+               ulong hval;
+               long index;
+
                switch (Z_TYPE_P(offset)) {
                        case IS_DOUBLE:
                                index = zend_dval_to_lval(Z_DVAL_P(offset));
@@ -7736,7 +8233,7 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_TMP_CV_HANDLER(ZEND_OPCODE
                        case IS_BOOL:
                                index = Z_LVAL_P(offset);
 num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(array_ptr), index, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_index_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), index, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_STRING:
                                if (IS_CV == IS_CONST) {
@@ -7749,10 +8246,10 @@ num_index:
                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                        }
                                }
-                               zend_hash_quick_update(Z_ARRVAL_P(array_ptr), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_quick_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_NULL:
-                               zend_hash_update(Z_ARRVAL_P(array_ptr), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
                                break;
                        default:
                                zend_error(E_WARNING, "Illegal offset type");
@@ -7762,19 +8259,20 @@ num_index:
                }
 
        } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(array_ptr), &expr_ptr, sizeof(zval *), NULL);
+               zend_hash_next_index_insert(Z_ARRVAL(EX_T(opline->result.var).tmp_var), &expr_ptr, sizeof(zval *), NULL);
        }
-       if (opline->extended_value) {
+       if ((IS_TMP_VAR == IS_VAR || IS_TMP_VAR == IS_CV) && opline->extended_value) {
 
        } else {
 
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (IS_TMP_VAR == IS_UNUSED) {
@@ -7788,47 +8286,56 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_TMP_CV_HANDLER(ZEND_OPCODE_HANDLE
 
 static int ZEND_FASTCALL  ZEND_BW_NOT_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        bitwise_not_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BOOL_NOT_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        boolean_not_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_PRE_INC_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **var_ptr;
+
+       SAVE_OPLINE();
+       var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (IS_VAR == IS_VAR && !var_ptr) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
-       if (IS_VAR == IS_VAR && *var_ptr == EG(error_zval_ptr)) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *val = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -7841,35 +8348,41 @@ static int ZEND_FASTCALL  ZEND_PRE_INC_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *var_ptr);
                PZVAL_LOCK(*var_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *var_ptr);
        }
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_PRE_DEC_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **var_ptr;
+
+       SAVE_OPLINE();
+       var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (IS_VAR == IS_VAR && !var_ptr) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
-       if (IS_VAR == IS_VAR && *var_ptr == EG(error_zval_ptr)) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *val = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -7882,37 +8395,44 @@ static int ZEND_FASTCALL  ZEND_PRE_DEC_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *var_ptr);
                PZVAL_LOCK(*var_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *var_ptr);
        }
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_POST_INC_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **var_ptr, *retval;
 
-       if (IS_VAR == IS_VAR && !var_ptr) {
+       SAVE_OPLINE();
+       var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
-       if (IS_VAR == IS_VAR && *var_ptr == EG(error_zval_ptr)) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       EX_T(opline->result.var).tmp_var = *EG(uninitialized_zval_ptr);
+                       ZVAL_NULL(&EX_T(opline->result.var).tmp_var);
                }
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
-       EX_T(opline->result.var).tmp_var = **var_ptr;
-       zendi_zval_copy_ctor(EX_T(opline->result.var).tmp_var);
+       retval = &EX_T(opline->result.var).tmp_var;
+       ZVAL_COPY_VALUE(retval, *var_ptr);
+       zendi_zval_copy_ctor(*retval);
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *val = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -7925,32 +8445,39 @@ static int ZEND_FASTCALL  ZEND_POST_INC_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
        }
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_POST_DEC_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **var_ptr, *retval;
+
+       SAVE_OPLINE();
+       var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (IS_VAR == IS_VAR && !var_ptr) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
-       if (IS_VAR == IS_VAR && *var_ptr == EG(error_zval_ptr)) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       EX_T(opline->result.var).tmp_var = *EG(uninitialized_zval_ptr);
+                       ZVAL_NULL(&EX_T(opline->result.var).tmp_var);
                }
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
-       EX_T(opline->result.var).tmp_var = **var_ptr;
-       zendi_zval_copy_ctor(EX_T(opline->result.var).tmp_var);
+       retval = &EX_T(opline->result.var).tmp_var;
+       ZVAL_COPY_VALUE(retval, *var_ptr);
+       zendi_zval_copy_ctor(*retval);
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *val = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -7963,18 +8490,23 @@ static int ZEND_FASTCALL  ZEND_POST_DEC_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
        }
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ECHO_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval z_copy;
-       zval *z = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *z;
+
+       SAVE_OPLINE();
+       z = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
        if (IS_VAR != IS_CONST &&
-           Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get_method != NULL &&
+           UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) &&
+           Z_OBJ_HT_P(z)->get_method != NULL &&
                zend_std_cast_object_tostring(z, &z_copy, IS_STRING TSRMLS_CC) == SUCCESS) {
                zend_print_variable(&z_copy);
                zval_dtor(&z_copy);
@@ -7983,31 +8515,33 @@ static int ZEND_FASTCALL  ZEND_ECHO_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
        }
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_PRINT_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-
-       Z_LVAL(EX_T(opline->result.var).tmp_var) = 1;
-       Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_LONG;
+       USE_OPLINE
 
+       ZVAL_LONG(&EX_T(opline->result.var).tmp_var, 1);
        return ZEND_ECHO_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
 static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_VAR(int type, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *varname = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *varname;
        zval **retval;
        zval tmp_varname;
        HashTable *target_symbol_table;
        ulong hash_value;
 
-       if (IS_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-               tmp_varname = *varname;
+       SAVE_OPLINE();
+       varname = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_VAR != IS_CONST && UNEXPECTED(Z_TYPE_P(varname) != IS_STRING)) {
+               ZVAL_COPY_VALUE(&tmp_varname, varname);
                zval_copy_ctor(&tmp_varname);
                convert_to_string(&tmp_varname);
                varname = &tmp_varname;
@@ -8020,6 +8554,7 @@ static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_VAR(int type, ZEND_O
                target_symbol_table = zend_get_target_symbol_table(opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
 /*
                if (!target_symbol_table) {
+                       CHECK_EXCEPTION();
                        ZEND_VM_NEXT_OPCODE();
                }
 */
@@ -8043,12 +8578,9 @@ static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_VAR(int type, ZEND_O
                                case BP_VAR_RW:
                                        zend_error(E_NOTICE,"Undefined variable: %s", Z_STRVAL_P(varname));
                                        /* break missing intentionally */
-                               case BP_VAR_W: {
-                                               zval *new_zval = &EG(uninitialized_zval);
-
-                                               Z_ADDREF_P(new_zval);
-                                               zend_hash_quick_update(target_symbol_table, Z_STRVAL_P(varname), Z_STRLEN_P(varname)+1, hash_value, &new_zval, sizeof(zval *), (void **) &retval);
-                                       }
+                               case BP_VAR_W:
+                                       Z_ADDREF_P(&EG(uninitialized_zval));
+                                       zend_hash_quick_update(target_symbol_table, Z_STRVAL_P(varname), Z_STRLEN_P(varname)+1, hash_value, &EG(uninitialized_zval_ptr), sizeof(zval *), (void **) &retval);
                                        break;
                                EMPTY_SWITCH_DEFAULT_CASE()
                        }
@@ -8075,7 +8607,7 @@ static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_VAR(int type, ZEND_O
 
 
        if (IS_VAR != IS_CONST && varname == &tmp_varname) {
-               zval_dtor(varname);
+               zval_dtor(&tmp_varname);
        }
        if (RETURN_VALUE_USED(opline)) {
                if (opline->extended_value & ZEND_FETCH_MAKE_REF) {
@@ -8085,25 +8617,25 @@ static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_VAR(int type, ZEND_O
                switch (type) {
                        case BP_VAR_R:
                        case BP_VAR_IS:
-                               AI_SET_PTR(EX_T(opline->result.var).var, *retval);
+                               AI_SET_PTR(&EX_T(opline->result.var), *retval);
                                break;
                        case BP_VAR_UNSET: {
                                zend_free_op free_res;
 
-                               EX_T(opline->result.var).var.ptr_ptr = retval;
-                               PZVAL_UNLOCK(*EX_T(opline->result.var).var.ptr_ptr, &free_res);
-                               if (EX_T(opline->result.var).var.ptr_ptr != &EG(uninitialized_zval_ptr)) {
-                                       SEPARATE_ZVAL_IF_NOT_REF(EX_T(opline->result.var).var.ptr_ptr);
+                               PZVAL_UNLOCK(*retval, &free_res);
+                               if (retval != &EG(uninitialized_zval_ptr)) {
+                                       SEPARATE_ZVAL_IF_NOT_REF(retval);
                                }
-                               PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
+                               PZVAL_LOCK(*retval);
                                FREE_OP_VAR_PTR(free_res);
-                               break;
+                       }
+                       /* break missing intentionally */
                        default:
                                EX_T(opline->result.var).var.ptr_ptr = retval;
                                break;
-                       }
                }
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -8124,7 +8656,9 @@ static int ZEND_FASTCALL  ZEND_FETCH_RW_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
 
 static int ZEND_FASTCALL  ZEND_FETCH_FUNC_ARG_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_var_address_helper_SPEC_VAR(ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (EX(opline)->extended_value & ZEND_FETCH_ARG_MASK))?BP_VAR_W:BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       USE_OPLINE
+
+       return zend_fetch_var_address_helper_SPEC_VAR(ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))?BP_VAR_W:BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_UNSET_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
@@ -8139,18 +8673,21 @@ static int ZEND_FASTCALL  ZEND_FETCH_IS_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
 
 static int ZEND_FASTCALL  ZEND_JMPZ_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *val = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *val;
        int ret;
 
-       if (IS_VAR == IS_TMP_VAR && Z_TYPE_P(val) == IS_BOOL) {
+       SAVE_OPLINE();
+       val = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_VAR == IS_TMP_VAR && EXPECTED(Z_TYPE_P(val) == IS_BOOL)) {
                ret = Z_LVAL_P(val);
        } else {
                ret = i_zend_is_true(val);
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       ZEND_VM_CONTINUE();
+                       HANDLE_EXCEPTION();
                }
        }
        if (!ret) {
@@ -8166,18 +8703,21 @@ static int ZEND_FASTCALL  ZEND_JMPZ_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 
 static int ZEND_FASTCALL  ZEND_JMPNZ_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *val = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *val;
        int ret;
 
-       if (IS_VAR == IS_TMP_VAR && Z_TYPE_P(val) == IS_BOOL) {
+       SAVE_OPLINE();
+       val = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_VAR == IS_TMP_VAR && EXPECTED(Z_TYPE_P(val) == IS_BOOL)) {
                ret = Z_LVAL_P(val);
        } else {
                ret = i_zend_is_true(val);
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       ZEND_VM_CONTINUE();
+                       HANDLE_EXCEPTION();
                }
        }
        if (ret) {
@@ -8193,18 +8733,21 @@ static int ZEND_FASTCALL  ZEND_JMPNZ_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 
 static int ZEND_FASTCALL  ZEND_JMPZNZ_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *val = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *val;
        int retval;
 
-       if (IS_VAR == IS_TMP_VAR && Z_TYPE_P(val) == IS_BOOL) {
+       SAVE_OPLINE();
+       val = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_VAR == IS_TMP_VAR && EXPECTED(Z_TYPE_P(val) == IS_BOOL)) {
                retval = Z_LVAL_P(val);
        } else {
                retval = i_zend_is_true(val);
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       ZEND_VM_CONTINUE();
+                       HANDLE_EXCEPTION();
                }
        }
        if (EXPECTED(retval != 0)) {
@@ -8224,18 +8767,21 @@ static int ZEND_FASTCALL  ZEND_JMPZNZ_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 
 static int ZEND_FASTCALL  ZEND_JMPZ_EX_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *val = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *val;
        int retval;
 
-       if (IS_VAR == IS_TMP_VAR && Z_TYPE_P(val) == IS_BOOL) {
+       SAVE_OPLINE();
+       val = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_VAR == IS_TMP_VAR && EXPECTED(Z_TYPE_P(val) == IS_BOOL)) {
                retval = Z_LVAL_P(val);
        } else {
                retval = i_zend_is_true(val);
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       ZEND_VM_CONTINUE();
+                       HANDLE_EXCEPTION();
                }
        }
        Z_LVAL(EX_T(opline->result.var).tmp_var) = retval;
@@ -8252,18 +8798,21 @@ static int ZEND_FASTCALL  ZEND_JMPZ_EX_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS
 
 static int ZEND_FASTCALL  ZEND_JMPNZ_EX_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *val = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *val;
        int retval;
 
-       if (IS_VAR == IS_TMP_VAR && Z_TYPE_P(val) == IS_BOOL) {
+       SAVE_OPLINE();
+       val = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_VAR == IS_TMP_VAR && EXPECTED(Z_TYPE_P(val) == IS_BOOL)) {
                retval = Z_LVAL_P(val);
        } else {
                retval = i_zend_is_true(val);
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       ZEND_VM_CONTINUE();
+                       HANDLE_EXCEPTION();
                }
        }
        Z_LVAL(EX_T(opline->result.var).tmp_var) = retval;
@@ -8280,12 +8829,13 @@ static int ZEND_FASTCALL  ZEND_JMPNZ_EX_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
 
 static int ZEND_FASTCALL  ZEND_RETURN_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *retval_ptr;
        zval **retval_ptr_ptr;
        zend_free_op free_op1;
 
-       if (EG(active_op_array)->return_reference == ZEND_RETURN_REF) {
+       SAVE_OPLINE();
+       if (UNEXPECTED(EG(active_op_array)->return_reference == ZEND_RETURN_REF)) {
 
                if (IS_VAR == IS_CONST || IS_VAR == IS_TMP_VAR) {
                        /* Not supposed to happen, but we'll allow it */
@@ -8293,9 +8843,9 @@ static int ZEND_FASTCALL  ZEND_RETURN_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
                        goto return_by_value;
                }
 
-               retval_ptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+               retval_ptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-               if (IS_VAR == IS_VAR && !retval_ptr_ptr) {
+               if (IS_VAR == IS_VAR && UNEXPECTED(retval_ptr_ptr == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot return string offsets by reference");
                }
 
@@ -8317,10 +8867,12 @@ static int ZEND_FASTCALL  ZEND_RETURN_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 
                        (*EG(return_value_ptr_ptr)) = (*retval_ptr_ptr);
                }
+               if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else {
 return_by_value:
 
-               retval_ptr = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+               retval_ptr = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
                if (!EG(return_value_ptr_ptr)) {
                        if (IS_VAR == IS_TMP_VAR) {
@@ -8347,21 +8899,22 @@ return_by_value:
                        INIT_PZVAL_COPY(ret, retval_ptr);
                        *EG(return_value_ptr_ptr) = ret;
                }
+               if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
-       if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
-       return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
 static int ZEND_FASTCALL  ZEND_THROW_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *value;
        zval *exception;
        zend_free_op free_op1;
 
-       value = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       SAVE_OPLINE();
+       value = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (IS_VAR == IS_CONST || Z_TYPE_P(value) != IS_OBJECT) {
+       if (IS_VAR == IS_CONST || UNEXPECTED(Z_TYPE_P(value) != IS_OBJECT)) {
                zend_error_noreturn(E_ERROR, "Can only throw objects");
        }
        zend_exception_save(TSRMLS_C);
@@ -8375,12 +8928,14 @@ static int ZEND_FASTCALL  ZEND_THROW_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
        zend_throw_exception_object(exception TSRMLS_CC);
        zend_exception_restore(TSRMLS_C);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
-       ZEND_VM_NEXT_OPCODE();
+       HANDLE_EXCEPTION();
 }
 
 static int ZEND_FASTCALL  ZEND_SEND_VAL_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       SAVE_OPLINE();
        if (opline->extended_value==ZEND_DO_FCALL_BY_NAME
                && ARG_MUST_BE_SENT_BY_REF(EX(fbc), opline->op2.opline_num)) {
                        zend_error_noreturn(E_ERROR, "Cannot pass parameter %d by reference", opline->op2.opline_num);
@@ -8390,7 +8945,7 @@ static int ZEND_FASTCALL  ZEND_SEND_VAL_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
                zval *value;
                zend_free_op free_op1;
 
-               value = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+               value = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
                ALLOC_ZVAL(valptr);
                INIT_PZVAL_COPY(valptr, value);
@@ -8400,15 +8955,16 @@ static int ZEND_FASTCALL  ZEND_SEND_VAL_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
                zend_vm_stack_push(valptr TSRMLS_CC);
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_send_by_var_helper_SPEC_VAR(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *varptr;
        zend_free_op free_op1;
-       varptr = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       varptr = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
        if (varptr == &EG(uninitialized_zval)) {
                ALLOC_ZVAL(varptr);
@@ -8418,7 +8974,7 @@ static int ZEND_FASTCALL zend_send_by_var_helper_SPEC_VAR(ZEND_OPCODE_HANDLER_AR
                zval *original_var = varptr;
 
                ALLOC_ZVAL(varptr);
-               *varptr = *original_var;
+               ZVAL_COPY_VALUE(varptr, original_var);
                Z_UNSET_ISREF_P(varptr);
                Z_SET_REFCOUNT_P(varptr, 0);
                zval_copy_ctor(varptr);
@@ -8427,15 +8983,17 @@ static int ZEND_FASTCALL zend_send_by_var_helper_SPEC_VAR(ZEND_OPCODE_HANDLER_AR
        zend_vm_stack_push(varptr TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};  /* for string offsets */
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SEND_VAR_NO_REF_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *varptr;
 
+       SAVE_OPLINE();
        if (opline->extended_value & ZEND_ARG_COMPILE_TIME_BOUND) { /* Had function_ptr at compile_time */
                if (!(opline->extended_value & ZEND_ARG_SEND_BY_REF)) {
                        return zend_send_by_var_helper_SPEC_VAR(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
@@ -8451,7 +9009,7 @@ static int ZEND_FASTCALL  ZEND_SEND_VAR_NO_REF_SPEC_VAR_HANDLER(ZEND_OPCODE_HAND
                varptr = EX_T(opline->op1.var).var.ptr;
                PZVAL_UNLOCK_EX(varptr, &free_op1, 0);
        } else {
-               varptr = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+               varptr = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
        }
        if ((!(opline->extended_value & ZEND_ARG_SEND_FUNCTION) ||
             EX_T(opline->op1.var).var.fcall_returned_reference) &&
@@ -8477,24 +9035,27 @@ static int ZEND_FASTCALL  ZEND_SEND_VAR_NO_REF_SPEC_VAR_HANDLER(ZEND_OPCODE_HAND
                zend_vm_stack_push(valptr TSRMLS_CC);
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SEND_REF_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval **varptr_ptr;
        zval *varptr;
-       varptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
 
-       if (IS_VAR == IS_VAR && !varptr_ptr) {
+       SAVE_OPLINE();
+       varptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(varptr_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Only variables can be passed by reference");
        }
 
-       if (EX(function_state).function->type == ZEND_INTERNAL_FUNCTION && !ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), opline->op2.opline_num)) {
-               return zend_send_by_var_helper_SPEC_VAR(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-        }
+       if (EX(function_state).function->type == ZEND_INTERNAL_FUNCTION && !ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), opline->op2.opline_num)) {
+               return zend_send_by_var_helper_SPEC_VAR(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
 
        SEPARATE_ZVAL_TO_MAKE_IS_REF(varptr_ptr);
        varptr = *varptr_ptr;
@@ -8502,60 +9063,69 @@ static int ZEND_FASTCALL  ZEND_SEND_REF_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
        zend_vm_stack_push(varptr TSRMLS_CC);
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SEND_VAR_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        if ((opline->extended_value == ZEND_DO_FCALL_BY_NAME)
                && ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), opline->op2.opline_num)) {
                return ZEND_SEND_REF_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
+       SAVE_OPLINE();
        return zend_send_by_var_helper_SPEC_VAR(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
 static int ZEND_FASTCALL  ZEND_BOOL_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
+       zval *retval = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        /* PHP 3.0 returned "" for false and 1 for true, here we use 0 and 1 for now */
-       Z_LVAL(EX_T(opline->result.var).tmp_var) = i_zend_is_true(_get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC));
-       Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
+       ZVAL_BOOL(retval, i_zend_is_true(_get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC)));
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SWITCH_FREE_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
+       SAVE_OPLINE();
        zend_switch_free(&EX_T(opline->op1.var), opline->extended_value TSRMLS_CC);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CLONE_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *obj = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *obj;
        zend_class_entry *ce;
        zend_function *clone;
        zend_object_clone_obj_t clone_call;
 
+       SAVE_OPLINE();
+       obj = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
        if (IS_VAR == IS_CONST ||
-           (IS_VAR == IS_VAR && !obj) ||
-           Z_TYPE_P(obj) != IS_OBJECT) {
+           (IS_VAR == IS_VAR && UNEXPECTED(obj == NULL)) ||
+           UNEXPECTED(Z_TYPE_P(obj) != IS_OBJECT)) {
                zend_error_noreturn(E_ERROR, "__clone method called on non-object");
        }
 
        ce = Z_OBJCE_P(obj);
        clone = ce ? ce->clone : NULL;
        clone_call =  Z_OBJ_HT_P(obj)->clone_obj;
-       if (!clone_call) {
+       if (UNEXPECTED(clone_call == NULL)) {
                if (ce) {
                        zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object of class %s", ce->name);
                } else {
@@ -8567,42 +9137,49 @@ static int ZEND_FASTCALL  ZEND_CLONE_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
                if (clone->op_array.fn_flags & ZEND_ACC_PRIVATE) {
                        /* Ensure that if we're calling a private function, we're allowed to do so.
                         */
-                       if (ce != EG(scope)) {
+                       if (UNEXPECTED(ce != EG(scope))) {
                                zend_error_noreturn(E_ERROR, "Call to private %s::__clone() from context '%s'", ce->name, EG(scope) ? EG(scope)->name : "");
                        }
                } else if ((clone->common.fn_flags & ZEND_ACC_PROTECTED)) {
                        /* Ensure that if we're calling a protected function, we're allowed to do so.
                         */
-                       if (!zend_check_protected(clone->common.scope, EG(scope))) {
+                       if (UNEXPECTED(!zend_check_protected(clone->common.scope, EG(scope)))) {
                                zend_error_noreturn(E_ERROR, "Call to protected %s::__clone() from context '%s'", ce->name, EG(scope) ? EG(scope)->name : "");
                        }
                }
        }
 
-       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-       if (!EG(exception)) {
-               ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-               Z_OBJVAL_P(EX_T(opline->result.var).var.ptr) = clone_call(obj TSRMLS_CC);
-               Z_TYPE_P(EX_T(opline->result.var).var.ptr) = IS_OBJECT;
-               Z_SET_REFCOUNT_P(EX_T(opline->result.var).var.ptr, 1);
-               Z_SET_ISREF_P(EX_T(opline->result.var).var.ptr);
-               if (!RETURN_VALUE_USED(opline) || EG(exception)) {
-                       zval_ptr_dtor(&EX_T(opline->result.var).var.ptr);
+       if (EXPECTED(EG(exception) == NULL)) {
+               zval *retval;
+
+               ALLOC_ZVAL(retval);
+               Z_OBJVAL_P(retval) = clone_call(obj TSRMLS_CC);
+               Z_TYPE_P(retval) = IS_OBJECT;
+               Z_SET_REFCOUNT_P(retval, 1);
+               Z_SET_ISREF_P(retval);
+               if (!RETURN_VALUE_USED(opline) || UNEXPECTED(EG(exception) != NULL)) {
+                       zval_ptr_dtor(&retval);
+               } else {
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                }
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CAST_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *expr = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *expr;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
+       expr = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
        if (opline->extended_value != IS_STRING) {
-               *result = *expr;
+               ZVAL_COPY_VALUE(result, expr);
                if (!0) {
                        zendi_zval_copy_ctor(*result);
                }
@@ -8626,12 +9203,12 @@ static int ZEND_FASTCALL  ZEND_CAST_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 
                        zend_make_printable_zval(expr, &var_copy, &use_copy);
                        if (use_copy) {
-                               *result = var_copy;
+                               ZVAL_COPY_VALUE(result, &var_copy);
                                if (0) {
                                        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
                                }
                        } else {
-                               *result = *expr;
+                               ZVAL_COPY_VALUE(result, expr);
                                if (!0) {
                                        zendi_zval_copy_ctor(*result);
                                }
@@ -8646,28 +9223,29 @@ static int ZEND_FASTCALL  ZEND_CAST_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
                        break;
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INCLUDE_OR_EVAL_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_op_array *new_op_array=NULL;
-       int return_value_used;
        zend_free_op free_op1;
-       zval *inc_filename = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *inc_filename;
        zval tmp_inc_filename;
        zend_bool failure_retval=0;
 
+       SAVE_OPLINE();
+       inc_filename = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
        if (inc_filename->type!=IS_STRING) {
-               tmp_inc_filename = *inc_filename;
+               ZVAL_COPY_VALUE(&tmp_inc_filename, inc_filename);
                zval_copy_ctor(&tmp_inc_filename);
                convert_to_string(&tmp_inc_filename);
                inc_filename = &tmp_inc_filename;
        }
 
-       return_value_used = RETURN_VALUE_USED(opline);
-
        switch (opline->extended_value) {
                case ZEND_INCLUDE_ONCE:
                case ZEND_REQUIRE_ONCE: {
@@ -8725,12 +9303,18 @@ static int ZEND_FASTCALL  ZEND_INCLUDE_OR_EVAL_SPEC_VAR_HANDLER(ZEND_OPCODE_HAND
                zval_dtor(&tmp_inc_filename);
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
-       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-       if (new_op_array && !EG(exception)) {
+       if (UNEXPECTED(EG(exception) != NULL)) {
+               HANDLE_EXCEPTION();
+       } else if (EXPECTED(new_op_array != NULL)) {
                EX(original_return_value) = EG(return_value_ptr_ptr);
-               EG(return_value_ptr_ptr) = return_value_used ? EX_T(opline->result.var).var.ptr_ptr : NULL;
                EG(active_op_array) = new_op_array;
-               EX_T(opline->result.var).var.ptr = NULL;
+               if (RETURN_VALUE_USED(opline)) {
+                       EX_T(opline->result.var).var.ptr = NULL;
+                       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
+                       EG(return_value_ptr_ptr) = EX_T(opline->result.var).var.ptr_ptr;
+               } else {
+                       EG(return_value_ptr_ptr) = NULL;
+               }
 
                EX(current_object) = EX(object);
 
@@ -8741,8 +9325,7 @@ static int ZEND_FASTCALL  ZEND_INCLUDE_OR_EVAL_SPEC_VAR_HANDLER(ZEND_OPCODE_HAND
                        zend_rebuild_symbol_table(TSRMLS_C);
                }
 
-               if (zend_execute == execute) {
-                       EX(call_opline) = opline;
+               if (EXPECTED(zend_execute == execute)) {
                        ZEND_VM_ENTER();
                } else {
                        zend_execute(new_op_array TSRMLS_CC);
@@ -8751,75 +9334,62 @@ static int ZEND_FASTCALL  ZEND_INCLUDE_OR_EVAL_SPEC_VAR_HANDLER(ZEND_OPCODE_HAND
                EX(function_state).function = (zend_function *) EX(op_array);
                EX(object) = EX(current_object);
 
-               if (return_value_used) {
-                       if (!EX_T(opline->result.var).var.ptr) { /* there was no return statement */
-                               ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                               INIT_PZVAL(EX_T(opline->result.var).var.ptr);
-                               Z_LVAL_P(EX_T(opline->result.var).var.ptr) = 1;
-                               Z_TYPE_P(EX_T(opline->result.var).var.ptr) = IS_BOOL;
-                       }
-               }
-
                EG(opline_ptr) = &EX(opline);
                EG(active_op_array) = EX(op_array);
                EG(return_value_ptr_ptr) = EX(original_return_value);
                destroy_op_array(new_op_array TSRMLS_CC);
                efree(new_op_array);
-               if (EG(exception)) {
+               if (UNEXPECTED(EG(exception) != NULL)) {
                        zend_throw_exception_internal(NULL TSRMLS_CC);
+                       HANDLE_EXCEPTION();
+               } else if (RETURN_VALUE_USED(opline)) {
+                       if (!EX_T(opline->result.var).var.ptr) { /* there was no return statement */
+                               zval *retval;
+
+                               ALLOC_ZVAL(retval);
+                               ZVAL_BOOL(retval, 1);
+                               INIT_PZVAL(retval);
+                               EX_T(opline->result.var).var.ptr = retval;
+                       }
                }
-       } else {
-               if (return_value_used) {
-                       ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                       INIT_ZVAL(*EX_T(opline->result.var).var.ptr);
-                       Z_LVAL_P(EX_T(opline->result.var).var.ptr) = failure_retval;
-                       Z_TYPE_P(EX_T(opline->result.var).var.ptr) = IS_BOOL;
-               }
+
+       } else if (RETURN_VALUE_USED(opline)) {
+               zval *retval;
+
+               ALLOC_ZVAL(retval);
+               ZVAL_BOOL(retval, failure_retval);
+               INIT_PZVAL(retval);
+               AI_SET_PTR(&EX_T(opline->result.var), retval);
        }
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval tmp, *varname;
        HashTable *target_symbol_table;
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        if (IS_VAR == IS_CV && (opline->extended_value & ZEND_QUICK_SET)) {
                if (EG(active_symbol_table)) {
-                       zend_execute_data *ex = EX(prev_execute_data);
                        zend_compiled_variable *cv = &CV_DEF_OF(opline->op1.var);
 
-                       if (zend_hash_quick_del(EG(active_symbol_table), cv->name, cv->name_len+1, cv->hash_value) == SUCCESS) {
-                               while (ex && ex->symbol_table == EG(active_symbol_table)) {
-                                       int i;
-
-                                       if (ex->op_array) {
-                                               for (i = 0; i < ex->op_array->last_var; i++) {
-                                                       if (ex->op_array->vars[i].hash_value == cv->hash_value &&
-                                                               ex->op_array->vars[i].name_len == cv->name_len &&
-                                                               !memcmp(ex->op_array->vars[i].name, cv->name, cv->name_len)) {
-                                                               ex->CVs[i] = NULL;
-                                                               break;
-                                                       }
-                                               }
-                                       }
-                                       ex = ex->prev_execute_data;
-                               }
-                       }
-                       EX(CVs)[opline->op1.var] = NULL;
-               } else if (EX(CVs)[opline->op1.var]) {
-                       zval_ptr_dtor(EX(CVs)[opline->op1.var]);
-                       EX(CVs)[opline->op1.var] = NULL;
+                       zend_delete_variable(EX(prev_execute_data), EG(active_symbol_table),  cv->name, cv->name_len+1, cv->hash_value TSRMLS_CC);
+                       EX_CV(opline->op1.var) = NULL;
+               } else if (EX_CV(opline->op1.var)) {
+                       zval_ptr_dtor(EX_CV(opline->op1.var));
+                       EX_CV(opline->op1.var) = NULL;
                }
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
-       varname = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       varname = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
        if (IS_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-               tmp = *varname;
+               ZVAL_COPY_VALUE(&tmp, varname);
                zval_copy_ctor(&tmp);
                convert_to_string(&tmp);
                varname = &tmp;
@@ -8833,39 +9403,22 @@ static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_AR
                ulong hash_value = zend_inline_hash_func(varname->value.str.val, varname->value.str.len+1);
 
                target_symbol_table = zend_get_target_symbol_table(opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-               if (zend_hash_quick_del(target_symbol_table, varname->value.str.val, varname->value.str.len+1, hash_value) == SUCCESS) {
-                       zend_execute_data *ex = execute_data;
-
-                       do {
-                               int i;
-
-                               if (ex->op_array) {
-                                       for (i = 0; i < ex->op_array->last_var; i++) {
-                                               if (ex->op_array->vars[i].hash_value == hash_value &&
-                                                       ex->op_array->vars[i].name_len == varname->value.str.len &&
-                                                       !memcmp(ex->op_array->vars[i].name, varname->value.str.val, varname->value.str.len)) {
-                                                       ex->CVs[i] = NULL;
-                                                       break;
-                                               }
-                                       }
-                               }
-                               ex = ex->prev_execute_data;
-                       } while (ex && ex->symbol_table == target_symbol_table);
-               }
+               zend_delete_variable(execute_data, target_symbol_table, varname->value.str.val, varname->value.str.len+1, hash_value TSRMLS_CC);
        }
 
-       if (varname == &tmp) {
+       if (IS_VAR != IS_CONST && varname == &tmp) {
                zval_dtor(&tmp);
        } else if (IS_VAR == IS_VAR || IS_VAR == IS_CV) {
                zval_ptr_dtor(&varname);
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *array_ptr, **array_ptr_ptr;
        HashTable *fe_ht;
@@ -8873,10 +9426,13 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
        zend_class_entry *ce = NULL;
        zend_bool is_empty = 0;
 
+       SAVE_OPLINE();
+
        if (opline->extended_value & ZEND_FE_RESET_VARIABLE) {
-               array_ptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+               array_ptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
                if (array_ptr_ptr == NULL || array_ptr_ptr == &EG(uninitialized_zval_ptr)) {
-                       ALLOC_INIT_ZVAL(array_ptr);
+                       MAKE_STD_ZVAL(array_ptr);
+                       ZVAL_NULL(array_ptr);
                } else if (Z_TYPE_PP(array_ptr_ptr) == IS_OBJECT) {
                        if(Z_OBJ_HT_PP(array_ptr_ptr)->get_class_entry == NULL) {
                                zend_error(E_WARNING, "foreach() cannot iterate over objects without PHP class");
@@ -8900,7 +9456,7 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
                        Z_ADDREF_P(array_ptr);
                }
        } else {
-               array_ptr = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+               array_ptr = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
                if (0) { /* IS_TMP_VAR */
                        zval *tmp;
 
@@ -8936,7 +9492,7 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
        if (ce && ce->get_iterator) {
                iter = ce->get_iterator(ce, array_ptr, opline->extended_value & ZEND_FE_RESET_REFERENCE TSRMLS_CC);
 
-               if (iter && !EG(exception)) {
+               if (iter && EXPECTED(EG(exception) == NULL)) {
                        array_ptr = zend_iterator_wrap(iter TSRMLS_CC);
                } else {
                        if (opline->extended_value & ZEND_FE_RESET_VARIABLE) {
@@ -8948,18 +9504,18 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
                                zend_throw_exception_ex(NULL, 0 TSRMLS_CC, "Object of type %s did not create an Iterator", ce->name);
                        }
                        zend_throw_exception_internal(NULL TSRMLS_CC);
-                       ZEND_VM_NEXT_OPCODE();
+                       HANDLE_EXCEPTION();
                }
        }
 
-       AI_SET_PTR(EX_T(opline->result.var).var, array_ptr);
        PZVAL_LOCK(array_ptr);
+       AI_SET_PTR(&EX_T(opline->result.var), array_ptr);
 
        if (iter) {
                iter->index = 0;
                if (iter->funcs->rewind) {
                        iter->funcs->rewind(iter TSRMLS_CC);
-                       if (EG(exception)) {
+                       if (UNEXPECTED(EG(exception) != NULL)) {
                                Z_DELREF_P(array_ptr);
                                zval_ptr_dtor(&array_ptr);
                                if (opline->extended_value & ZEND_FE_RESET_VARIABLE) {
@@ -8967,11 +9523,11 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
                                } else {
                                        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
                                }
-                               ZEND_VM_NEXT_OPCODE();
+                               HANDLE_EXCEPTION();
                        }
                }
                is_empty = iter->funcs->valid(iter TSRMLS_CC) != SUCCESS;
-               if (EG(exception)) {
+               if (UNEXPECTED(EG(exception) != NULL)) {
                        Z_DELREF_P(array_ptr);
                        zval_ptr_dtor(&array_ptr);
                        if (opline->extended_value & ZEND_FE_RESET_VARIABLE) {
@@ -8979,7 +9535,7 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
                        } else {
                                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
                        }
-                       ZEND_VM_NEXT_OPCODE();
+                       HANDLE_EXCEPTION();
                }
                iter->index = -1; /* will be set to 0 before using next handler */
        } else if ((fe_ht = HASH_OF(array_ptr)) != NULL) {
@@ -9016,13 +9572,14 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
        if (is_empty) {
                ZEND_VM_JMP(EX(op_array)->opcodes+opline->op2.opline_num);
        } else {
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 }
 
 static int ZEND_FASTCALL  ZEND_FE_FETCH_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *array = EX_T(opline->op1.var).var.ptr;
        zval **value;
@@ -9034,6 +9591,8 @@ static int ZEND_FASTCALL  ZEND_FE_FETCH_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
        int key_type = 0;
        zend_bool use_key = (zend_bool)(opline->extended_value & ZEND_FE_FETCH_WITH_KEY);
 
+       SAVE_OPLINE();
+
        switch (zend_iterator_unwrap(array, &iter TSRMLS_CC)) {
                default:
                case ZEND_ITER_INVALID:
@@ -9044,7 +9603,7 @@ static int ZEND_FASTCALL  ZEND_FE_FETCH_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
                        char *class_name, *prop_name;
                        zend_object *zobj = zend_objects_get_address(array TSRMLS_CC);
 
-                       fe_ht = HASH_OF(array);
+                       fe_ht = Z_OBJPROP_P(array);
                        zend_hash_set_pointer(fe_ht, &EX_T(opline->op1.var).fe.fe_pos);
                        do {
                                if (zend_hash_get_current_data(fe_ht, (void **) &value)==FAILURE) {
@@ -9068,7 +9627,7 @@ static int ZEND_FASTCALL  ZEND_FE_FETCH_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
                }
 
                case ZEND_ITER_PLAIN_ARRAY:
-                       fe_ht = HASH_OF(array);
+                       fe_ht = Z_ARRVAL_P(array);
                        zend_hash_set_pointer(fe_ht, &EX_T(opline->op1.var).fe.fe_pos);
                        if (zend_hash_get_current_data(fe_ht, (void **) &value)==FAILURE) {
                                /* reached end of iteration */
@@ -9087,27 +9646,27 @@ static int ZEND_FASTCALL  ZEND_FE_FETCH_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
                                /* This could cause an endless loop if index becomes zero again.
                                 * In case that ever happens we need an additional flag. */
                                iter->funcs->move_forward(iter TSRMLS_CC);
-                               if (EG(exception)) {
+                               if (UNEXPECTED(EG(exception) != NULL)) {
                                        Z_DELREF_P(array);
                                        zval_ptr_dtor(&array);
-                                       ZEND_VM_NEXT_OPCODE();
+                                       HANDLE_EXCEPTION();
                                }
                        }
                        /* If index is zero we come from FE_RESET and checked valid() already. */
                        if (!iter || (iter->index > 0 && iter->funcs->valid(iter TSRMLS_CC) == FAILURE)) {
                                /* reached end of iteration */
-                               if (EG(exception)) {
+                               if (UNEXPECTED(EG(exception) != NULL)) {
                                        Z_DELREF_P(array);
                                        zval_ptr_dtor(&array);
-                                       ZEND_VM_NEXT_OPCODE();
+                                       HANDLE_EXCEPTION();
                                }
                                ZEND_VM_JMP(EX(op_array)->opcodes+opline->op2.opline_num);
                        }
                        iter->funcs->get_current_data(iter, &value TSRMLS_CC);
-                       if (EG(exception)) {
+                       if (UNEXPECTED(EG(exception) != NULL)) {
                                Z_DELREF_P(array);
                                zval_ptr_dtor(&array);
-                               ZEND_VM_NEXT_OPCODE();
+                               HANDLE_EXCEPTION();
                        }
                        if (!value) {
                                /* failure in get_current_data */
@@ -9116,10 +9675,10 @@ static int ZEND_FASTCALL  ZEND_FE_FETCH_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
                        if (use_key) {
                                if (iter->funcs->get_current_key) {
                                        key_type = iter->funcs->get_current_key(iter, &str_key, &str_key_len, &int_key TSRMLS_CC);
-                                       if (EG(exception)) {
+                                       if (UNEXPECTED(EG(exception) != NULL)) {
                                                Z_DELREF_P(array);
                                                zval_ptr_dtor(&array);
-                                               ZEND_VM_NEXT_OPCODE();
+                                               HANDLE_EXCEPTION();
                                        }
                                } else {
                                        key_type = HASH_KEY_IS_LONG;
@@ -9135,13 +9694,12 @@ static int ZEND_FASTCALL  ZEND_FE_FETCH_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
                EX_T(opline->result.var).var.ptr_ptr = value;
                Z_ADDREF_PP(value);
        } else {
-               AI_SET_PTR(EX_T(opline->result.var).var, *value);
                PZVAL_LOCK(*value);
+               AI_SET_PTR(&EX_T(opline->result.var), *value);
        }
 
        if (use_key) {
-               zend_op *op_data = opline+1;
-               zval *key = &EX_T(op_data->result.var).tmp_var;
+               zval *key = &EX_T((opline+1)->result.var).tmp_var;
 
                switch (key_type) {
                        case HASH_KEY_IS_STRING:
@@ -9160,19 +9718,21 @@ static int ZEND_FASTCALL  ZEND_FE_FETCH_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval **value;
        zend_bool isset = 1;
 
+       SAVE_OPLINE();
        if (IS_VAR == IS_CV && (opline->extended_value & ZEND_QUICK_SET)) {
-               if (EX(CVs)[opline->op1.var]) {
-                       value = EX(CVs)[opline->op1.var];
+               if (EX_CV(opline->op1.var)) {
+                       value = EX_CV(opline->op1.var);
                } else if (EG(active_symbol_table)) {
                        zend_compiled_variable *cv = &CV_DEF_OF(opline->op1.var);
 
@@ -9185,10 +9745,10 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_VAR_HANDLER(ZEND_OPCODE_HA
        } else {
                HashTable *target_symbol_table;
                zend_free_op free_op1;
-               zval tmp, *varname = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+               zval tmp, *varname = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
                if (IS_VAR != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-                       tmp = *varname;
+                       ZVAL_COPY_VALUE(&tmp, varname);
                        zval_copy_ctor(&tmp);
                        convert_to_string(&tmp);
                        varname = &tmp;
@@ -9206,38 +9766,39 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_VAR_HANDLER(ZEND_OPCODE_HA
                        }
                }
 
-               if (varname == &tmp) {
+               if (IS_VAR != IS_CONST && varname == &tmp) {
                        zval_dtor(&tmp);
                }
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        }
 
-       Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
-
        if (opline->extended_value & ZEND_ISSET) {
-               if (isset && Z_TYPE_PP(value) == IS_NULL) {
-                       Z_LVAL(EX_T(opline->result.var).tmp_var) = 0;
+               if (isset && Z_TYPE_PP(value) != IS_NULL) {
+                       ZVAL_BOOL(&EX_T(opline->result.var).tmp_var, 1);
                } else {
-                       Z_LVAL(EX_T(opline->result.var).tmp_var) = isset;
+                       ZVAL_BOOL(&EX_T(opline->result.var).tmp_var, 0);
                }
        } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
                if (!isset || !i_zend_is_true(*value)) {
-                       Z_LVAL(EX_T(opline->result.var).tmp_var) = 1;
+                       ZVAL_BOOL(&EX_T(opline->result.var).tmp_var, 1);
                } else {
-                       Z_LVAL(EX_T(opline->result.var).tmp_var) = 0;
+                       ZVAL_BOOL(&EX_T(opline->result.var).tmp_var, 0);
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_EXIT_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
 #if 0 || (IS_VAR != IS_UNUSED)
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       SAVE_OPLINE();
        if (IS_VAR != IS_UNUSED) {
                zend_free_op free_op1;
-               zval *ptr = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+               zval *ptr = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
                if (Z_TYPE_P(ptr) == IS_LONG) {
                        EG(exit_status) = Z_LVAL_P(ptr);
@@ -9248,17 +9809,20 @@ static int ZEND_FASTCALL  ZEND_EXIT_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
        }
 #endif
        zend_bailout();
-       ZEND_VM_NEXT_OPCODE();
+       ZEND_VM_NEXT_OPCODE(); /* Never reached */
 }
 
 static int ZEND_FASTCALL  ZEND_JMP_SET_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *value = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *value;
+
+       SAVE_OPLINE();
+       value = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
        if (i_zend_is_true(value)) {
-               EX_T(opline->result.var).tmp_var = *value;
+               ZVAL_COPY_VALUE(&EX_T(opline->result.var).tmp_var, value);
                zendi_zval_copy_ctor(EX_T(opline->result.var).tmp_var);
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 #if DEBUG_ZEND>=2
@@ -9268,30 +9832,38 @@ static int ZEND_FASTCALL  ZEND_JMP_SET_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS
        }
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_QM_ASSIGN_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *value = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *value;
 
-       EX_T(opline->result.var).tmp_var = *value;
+       SAVE_OPLINE();
+       value = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       ZVAL_COPY_VALUE(&EX_T(opline->result.var).tmp_var, value);
        if (!0) {
                zval_copy_ctor(&EX_T(opline->result.var).tmp_var);
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INSTANCEOF_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *expr = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *expr;
        zend_bool result;
 
+       SAVE_OPLINE();
+       expr = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
        if (Z_TYPE_P(expr) == IS_OBJECT && Z_OBJ_HT_P(expr)->get_class_entry) {
                result = instanceof_function(Z_OBJCE_P(expr), EX_T(opline->op2.var).class_entry TSRMLS_CC);
        } else {
@@ -9299,282 +9871,317 @@ static int ZEND_FASTCALL  ZEND_INSTANCEOF_SPEC_VAR_HANDLER(ZEND_OPCODE_HANDLER_A
        }
        ZVAL_BOOL(&EX_T(opline->result.var).tmp_var, result);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        add_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SUB_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        sub_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MUL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        mul_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_DIV_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        div_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MOD_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        mod_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        shift_left_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        shift_right_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        concat_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        is_identical_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        is_identical_function(result,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        Z_LVAL_P(result) = !Z_LVAL_P(result);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) == 0));
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) != 0));
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) < 0));
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) <= 0));
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        bitwise_or_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        bitwise_and_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        bitwise_xor_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        boolean_xor_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op1, free_op_data1;
-       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
        zval *object;
        zval *property = opline->op2.zv;
-       zval *value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
+       zval *value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
        znode_op *result = &opline->result;
        int have_get_ptr = 0;
 
-       if (IS_VAR == IS_VAR && !object_ptr) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
 
-       EX_T(result->var).var.ptr_ptr = NULL;
        make_real_object(object_ptr TSRMLS_CC);
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to assign property of non-object");
 
                FREE_OP(free_op_data1);
 
                if (RETURN_VALUE_USED(opline)) {
-                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                       EX_T(result->var).var.ptr_ptr = NULL;
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                }
        } else {
                /* here we are sure we are dealing with an object */
@@ -9592,9 +10199,9 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(int (*b
                                have_get_ptr = 1;
                                binary_op(*zptr, *zptr, value TSRMLS_CC);
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = *zptr;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(*zptr);
+                                       EX_T(opline->result.var).var.ptr = *zptr;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -9631,17 +10238,17 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(int (*b
                                        Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
                                }
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = z;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(z);
+                                       EX_T(opline->result.var).var.ptr = z;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                                zval_ptr_dtor(&z);
                        } else {
                                zend_error(E_WARNING, "Attempt to assign property of non-object");
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                                       EX_T(result->var).var.ptr_ptr = NULL;
-                                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                                       PZVAL_LOCK(&EG(uninitialized_zval));
+                                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -9656,66 +10263,71 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(int (*b
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op_data2, free_op_data1;
        zval **var_ptr;
        zval *value;
 
+       SAVE_OPLINE();
        switch (opline->extended_value) {
                case ZEND_ASSIGN_OBJ:
                        return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                        break;
                case ZEND_ASSIGN_DIM: {
-                               zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+                               zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-                               if (IS_VAR == IS_VAR && !container) {
+                               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-                               } else if (Z_TYPE_PP(container) == IS_OBJECT) {
+                               } else if (UNEXPECTED(Z_TYPE_PP(container) == IS_OBJECT)) {
                                        if (IS_VAR == IS_VAR && !(free_op1.var != NULL)) {
                                                Z_ADDREF_PP(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
                                        }
                                        return zend_binary_assign_op_obj_helper_SPEC_VAR_CONST(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                                } else {
-                                       zend_op *op_data = opline+1;
                                        zval *dim = opline->op2.zv;
 
-                                       zend_fetch_dimension_address(&EX_T(op_data->op2.var), container, dim, IS_CONST, BP_VAR_RW TSRMLS_CC);
-                                       value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-                                       var_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-                                       ZEND_VM_INC_OPCODE();
+                                       zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), container, dim, IS_CONST, BP_VAR_RW TSRMLS_CC);
+                                       value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+                                       var_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
                                }
                        }
                        break;
                default:
                        value = opline->op2.zv;
-                       var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+                       var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
                        /* do nothing */
                        break;
        }
 
-       if (!var_ptr) {
+       if (UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
        }
 
-       if (*var_ptr == EG(error_zval_ptr)) {
+       if (UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
 
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
+               if (opline->extended_value == ZEND_ASSIGN_DIM) {
+                       ZEND_VM_INC_OPCODE();
+               }
                ZEND_VM_NEXT_OPCODE();
        }
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *objval = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -9728,15 +10340,20 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_CONST(int (*binar
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *var_ptr);
                PZVAL_LOCK(*var_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *var_ptr);
        }
 
        if (opline->extended_value == ZEND_ASSIGN_DIM) {
                FREE_OP(free_op_data1);
                FREE_OP_VAR_PTR(free_op_data2);
+               if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
+               ZEND_VM_INC_OPCODE();
+       } else {
+               if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
        }
-       if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -9797,29 +10414,35 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_
 
 static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **object_ptr;
        zval *object;
-       zval *property = opline->op2.zv;
-       zval **retval = &EX_T(opline->result.var).var.ptr;
+       zval *property;
+       zval **retval;
        int have_get_ptr = 0;
 
-       if (IS_VAR == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       property = opline->op2.zv;
+       retval = &EX_T(opline->result.var).var.ptr;
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
 
                if (RETURN_VALUE_USED(opline)) {
-                       *retval = EG(uninitialized_zval_ptr);
-                       PZVAL_LOCK(*retval);
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       *retval = &EG(uninitialized_zval);
                }
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -9847,7 +10470,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_CONST(incdec_t
                if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -9867,8 +10490,8 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_CONST(incdec_t
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                        if (RETURN_VALUE_USED(opline)) {
-                               *retval = EG(uninitialized_zval_ptr);
-                               PZVAL_LOCK(*retval);
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               *retval = &EG(uninitialized_zval);
                        }
                }
        }
@@ -9879,6 +10502,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_CONST(incdec_t
 
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -9894,26 +10518,32 @@ static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HA
 
 static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **object_ptr;
        zval *object;
-       zval *property = opline->op2.zv;
-       zval *retval = &EX_T(opline->result.var).tmp_var;
+       zval *property;
+       zval *retval;
        int have_get_ptr = 0;
 
-       if (IS_VAR == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       property = opline->op2.zv;
+       retval = &EX_T(opline->result.var).tmp_var;
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
 
-               *retval = *EG(uninitialized_zval_ptr);
+               ZVAL_NULL(retval);
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -9929,7 +10559,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_CONST(incdec_
                        have_get_ptr = 1;
                        SEPARATE_ZVAL_IF_NOT_REF(zptr);
 
-                       *retval = **zptr;
+                       ZVAL_COPY_VALUE(retval, *zptr);
                        zendi_zval_copy_ctor(*retval);
 
                        incdec_op(*zptr);
@@ -9942,7 +10572,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_CONST(incdec_
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
                        zval *z_copy;
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -9952,12 +10582,11 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_CONST(incdec_
                                }
                                z = value;
                        }
-                       *retval = *z;
+                       ZVAL_COPY_VALUE(retval, z);
                        zendi_zval_copy_ctor(*retval);
                        ALLOC_ZVAL(z_copy);
-                       *z_copy = *z;
+                       INIT_PZVAL_COPY(z_copy, z);
                        zendi_zval_copy_ctor(*z_copy);
-                       INIT_PZVAL(z_copy);
                        incdec_op(z_copy);
                        Z_ADDREF_P(z);
                        Z_OBJ_HT_P(object)->write_property(object, property, z_copy, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
@@ -9965,7 +10594,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_CONST(incdec_
                        zval_ptr_dtor(&z);
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-                       *retval = *EG(uninitialized_zval_ptr);
+                       ZVAL_NULL(retval);
                }
        }
 
@@ -9975,6 +10604,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_CONST(incdec_
 
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -9990,195 +10620,194 @@ static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_H
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *dim = opline->op2.zv;
        zval **container;
 
+       SAVE_OPLINE();
+
        if ((opline->extended_value & ZEND_FETCH_ADD_LOCK) &&
            IS_VAR != IS_CV &&
            EX_T(opline->op1.var).var.ptr_ptr) {
                PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
        }
-       container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       if (IS_VAR == IS_VAR && !container) {
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address_read(!RETURN_VALUE_USED(opline)?NULL:&EX_T(opline->result.var), container, dim, IS_CONST, BP_VAR_R TSRMLS_CC);
+       zend_fetch_dimension_address_read(!RETURN_VALUE_USED(opline)?NULL:&EX_T(opline->result.var), container, opline->op2.zv, IS_CONST, BP_VAR_R TSRMLS_CC);
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *dim = opline->op2.zv;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **container;
 
-       if (IS_VAR == IS_VAR && !container) {
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_CONST, BP_VAR_W TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, opline->op2.zv, IS_CONST, BP_VAR_W TSRMLS_CC);
 
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
        /* We are going to assign the result by reference */
-       if (opline->extended_value && EX_T(opline->result.var).var.ptr_ptr) {
-               Z_DELREF_PP(EX_T(opline->result.var).var.ptr_ptr);
-               SEPARATE_ZVAL_TO_MAKE_IS_REF(EX_T(opline->result.var).var.ptr_ptr);
-               Z_ADDREF_PP(EX_T(opline->result.var).var.ptr_ptr);
+       if (UNEXPECTED(opline->extended_value != 0)) {
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+
+               if (retval_ptr) {
+                       Z_DELREF_PP(retval_ptr);
+                       SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
+                       Z_ADDREF_PP(retval_ptr);
+               }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *dim = opline->op2.zv;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **container;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (IS_VAR == IS_VAR && !container) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_CONST, BP_VAR_RW TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, opline->op2.zv, IS_CONST, BP_VAR_RW TSRMLS_CC);
 
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *dim = opline->op2.zv;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **container;
 
-       if (IS_VAR == IS_VAR && !container) {
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, dim, IS_CONST, BP_VAR_IS TSRMLS_CC);
+       zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, opline->op2.zv, IS_CONST, BP_VAR_IS TSRMLS_CC);
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *dim = opline->op2.zv;
        zval **container;
 
+       SAVE_OPLINE();
+
        if (ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))) {
-               container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-               if (IS_VAR == IS_VAR && !container) {
+               container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_CONST, BP_VAR_W TSRMLS_CC);
-               if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-                   READY_TO_DESTROY(free_op1.var)) {
-                       AI_USE_PTR(EX_T(opline->result.var).var);
-                       if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                           Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                               SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-                       }
+               zend_fetch_dimension_address(&EX_T(opline->result.var), container, opline->op2.zv, IS_CONST, BP_VAR_W TSRMLS_CC);
+               if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+                       EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
                }
        } else {
                if (IS_CONST == IS_UNUSED) {
                        zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
                }
-               container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-               if (IS_VAR == IS_VAR && !container) {
+               container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, dim, IS_CONST, BP_VAR_R TSRMLS_CC);
+               zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, opline->op2.zv, IS_CONST, BP_VAR_R TSRMLS_CC);
        }
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_UNSET_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       zval *dim = opline->op2.zv;
+       zval **container;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       /* Not needed in DIM_UNSET
-       if (opline->extended_value & ZEND_FETCH_ADD_LOCK) {
-               PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
-       }
-       */
        if (IS_VAR == IS_CV) {
                if (container != &EG(uninitialized_zval_ptr)) {
                        SEPARATE_ZVAL_IF_NOT_REF(container);
                }
        }
-       if (IS_VAR == IS_VAR && !container) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_CONST, BP_VAR_UNSET TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, opline->op2.zv, IS_CONST, BP_VAR_UNSET TSRMLS_CC);
 
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
-       if (EX_T(opline->result.var).var.ptr_ptr == NULL) {
+       if (UNEXPECTED(EX_T(opline->result.var).var.ptr_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
        } else {
                zend_free_op free_res;
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
 
-               PZVAL_UNLOCK(*EX_T(opline->result.var).var.ptr_ptr, &free_res);
-               if (EX_T(opline->result.var).var.ptr_ptr != &EG(uninitialized_zval_ptr)) {
-                       SEPARATE_ZVAL_IF_NOT_REF(EX_T(opline->result.var).var.ptr_ptr);
+               PZVAL_UNLOCK(*retval_ptr, &free_res);
+               if (retval_ptr != &EG(uninitialized_zval_ptr)) {
+                       SEPARATE_ZVAL_IF_NOT_REF(retval_ptr);
                }
-               PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
+               PZVAL_LOCK(*retval_ptr);
                FREE_OP_VAR_PTR(free_res);
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
        }
-       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_VAR_CONST(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_VAR_CONST(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *container = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *container;
 
-       zval *offset  = opline->op2.zv;
+       zval *offset;
 
-       if (Z_TYPE_P(container) != IS_OBJECT || !Z_OBJ_HT_P(container)->read_property) {
-               if (type != BP_VAR_IS) {
-                       zend_error(E_NOTICE, "Trying to get property of non-object");
-               }
+       SAVE_OPLINE();
+       container = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       offset  = opline->op2.zv;
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               zend_error(E_NOTICE, "Trying to get property of non-object");
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
 
        } else {
@@ -10189,7 +10818,7 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_VAR_CONST(
                }
 
                /* here we are sure we are dealing with an object */
-               retval = Z_OBJ_HT_P(container)->read_property(container, offset, type, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
                if (!RETURN_VALUE_USED(opline)) {
                        if (Z_REFCOUNT_P(retval) == 0) {
@@ -10198,8 +10827,8 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_VAR_CONST(
                                FREE_ZVAL(retval);
                        }
                } else {
-                       AI_SET_PTR(EX_T(opline->result.var).var, retval);
                        PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                }
 
                if (0) {
@@ -10210,21 +10839,25 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_VAR_CONST(
        }
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_property_address_read_helper_SPEC_VAR_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_fetch_property_address_read_helper_SPEC_VAR_CONST(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *property = opline->op2.zv;
+       zval *property;
        zval **container;
 
+       SAVE_OPLINE();
+       property = opline->op2.zv;
+
        if (IS_VAR == IS_VAR && (opline->extended_value & ZEND_FETCH_ADD_LOCK)) {
                PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
                EX_T(opline->op1.var).var.ptr = *EX_T(opline->op1.var).var.ptr_ptr;
@@ -10233,47 +10866,50 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HA
        if (0) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       if (IS_VAR == IS_VAR && !container) {
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
+
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
        if (0) {
                zval_ptr_dtor(&property);
        } else {
 
        }
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
        /* We are going to assign the result by reference */
        if (opline->extended_value & ZEND_FETCH_MAKE_REF) {
-               Z_DELREF_PP(EX_T(opline->result.var).var.ptr_ptr);
-               SEPARATE_ZVAL_TO_MAKE_IS_REF(EX_T(opline->result.var).var.ptr_ptr);
-               Z_ADDREF_PP(EX_T(opline->result.var).var.ptr_ptr);
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+
+               Z_DELREF_PP(retval_ptr);
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
+               Z_ADDREF_PP(retval_ptr);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *property = opline->op2.zv;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *property;
+       zval **container;
+
+       SAVE_OPLINE();
+       property = opline->op2.zv;
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
        if (0) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       if (IS_VAR == IS_VAR && !container) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_RW TSRMLS_CC);
@@ -10282,37 +10918,84 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_H
        } else {
 
        }
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_property_address_read_helper_SPEC_VAR_CONST(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *container;
+
+       zval *offset;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       offset  = opline->op2.zv;
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               if (RETURN_VALUE_USED(opline)) {
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+               }
+
+       } else {
+               zval *retval;
+
+               if (0) {
+                       MAKE_REAL_ZVAL_PTR(offset);
+               }
+
+               /* here we are sure we are dealing with an object */
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+
+               if (!RETURN_VALUE_USED(opline)) {
+                       if (Z_REFCOUNT_P(retval) == 0) {
+                               GC_REMOVE_ZVAL_FROM_BUFFER(retval);
+                               zval_dtor(retval);
+                               FREE_ZVAL(retval);
+                       }
+               } else {
+                       PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
+               }
+
+               if (0) {
+                       zval_ptr_dtor(&offset);
+               } else {
+
+               }
+       }
+
+       if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        if (ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))) {
                /* Behave like FETCH_OBJ_W */
                zend_free_op free_op1;
-               zval *property = opline->op2.zv;
-               zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+               zval *property;
+               zval **container;
+
+               SAVE_OPLINE();
+               property = opline->op2.zv;
+               container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
                if (0) {
                        MAKE_REAL_ZVAL_PTR(property);
                }
-               if (IS_VAR == IS_VAR && !container) {
+               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
                }
                zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
@@ -10321,27 +11004,27 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_CONST_HANDLER(ZEND_OP
                } else {
 
                }
-               if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-                   READY_TO_DESTROY(free_op1.var)) {
-                       AI_USE_PTR(EX_T(opline->result.var).var);
-                       if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                           Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                               SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-                       }
+               if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+                       EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
                }
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
-               return zend_fetch_property_address_read_helper_SPEC_VAR_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_fetch_property_address_read_helper_SPEC_VAR_CONST(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_res;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       zval *property = opline->op2.zv;
+       zval **container;
+       zval *property;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       property = opline->op2.zv;
 
        if (IS_VAR == IS_CV) {
                if (container != &EG(uninitialized_zval_ptr)) {
@@ -10351,7 +11034,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_VAR_CONST_HANDLER(ZEND_OPCOD
        if (0) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       if (IS_VAR == IS_VAR && !container) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_UNSET TSRMLS_CC);
@@ -10360,13 +11043,8 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_VAR_CONST_HANDLER(ZEND_OPCOD
        } else {
 
        }
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
@@ -10376,24 +11054,28 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_VAR_CONST_HANDLER(ZEND_OPCOD
        }
        PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
        FREE_OP_VAR_PTR(free_res);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       zval *property_name = opline->op2.zv;
+       zval **object_ptr;
+       zval *property_name;
+
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       property_name = opline->op2.zv;
 
        if (0) {
                MAKE_REAL_ZVAL_PTR(property_name);
        }
-       if (IS_VAR == IS_VAR && !object_ptr) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, op_data->op1_type, &op_data->op1, EX(Ts), ZEND_ASSIGN_OBJ, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), ZEND_ASSIGN_OBJ, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
        if (0) {
                zval_ptr_dtor(&property_name);
        } else {
@@ -10401,18 +11083,21 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HAN
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **object_ptr;
+
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (IS_VAR == IS_VAR && !object_ptr) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
        if (Z_TYPE_PP(object_ptr) == IS_OBJECT) {
@@ -10422,7 +11107,7 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HAN
                if (0) {
                        MAKE_REAL_ZVAL_PTR(property_name);
                }
-               zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, op_data->op1_type, &op_data->op1, EX(Ts), ZEND_ASSIGN_DIM, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+               zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), ZEND_ASSIGN_DIM, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
                if (0) {
                        zval_ptr_dtor(&property_name);
                } else {
@@ -10434,27 +11119,41 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HAN
                zval *dim = opline->op2.zv;
                zval **variable_ptr_ptr;
 
-               zend_fetch_dimension_address(&EX_T(op_data->op2.var), object_ptr, dim, IS_CONST, BP_VAR_W TSRMLS_CC);
+               zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), object_ptr, dim, IS_CONST, BP_VAR_W TSRMLS_CC);
 
-               value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-               variable_ptr_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-               if (!variable_ptr_ptr) {
-                       if (zend_assign_to_string_offset(&EX_T(op_data->op2.var), value, op_data->op1_type TSRMLS_CC)) {
+               value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+               variable_ptr_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
+               if (UNEXPECTED(variable_ptr_ptr == NULL)) {
+                       if (zend_assign_to_string_offset(&EX_T((opline+1)->op2.var), value, (opline+1)->op1_type TSRMLS_CC)) {
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-                                       ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                                       INIT_PZVAL(EX_T(opline->result.var).var.ptr);
-                                       ZVAL_STRINGL(EX_T(opline->result.var).var.ptr, Z_STRVAL_P(EX_T(op_data->op2.var).str_offset.str)+EX_T(op_data->op2.var).str_offset.offset, 1, 1);
+                                       zval *retval;
+
+                                       ALLOC_ZVAL(retval);
+                                       ZVAL_STRINGL(retval, Z_STRVAL_P(EX_T((opline+1)->op2.var).str_offset.str)+EX_T((opline+1)->op2.var).str_offset.offset, 1, 1);
+                                       INIT_PZVAL(retval);
+                                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                                }
                        } else if (RETURN_VALUE_USED(opline)) {
-                               AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                               PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+                       }
+               } else if (UNEXPECTED(*variable_ptr_ptr == &EG(error_zval))) {
+                       if (IS_TMP_FREE(free_op_data1)) {
+                               zval_dtor(value);
+                       }
+                       if (RETURN_VALUE_USED(opline)) {
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                        }
                } else {
-                       value = zend_assign_to_variable(variable_ptr_ptr, value, IS_TMP_FREE(free_op_data1) TSRMLS_CC);
+                       if (IS_TMP_FREE(free_op_data1)) {
+                               value = zend_assign_tmp_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+                       } else {
+                               value = zend_assign_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+                       }
                        if (RETURN_VALUE_USED(opline)) {
-                               AI_SET_PTR(EX_T(opline->result.var).var, value);
                                PZVAL_LOCK(value);
+                               AI_SET_PTR(&EX_T(opline->result.var), value);
                        }
                }
                FREE_OP_VAR_PTR(free_op_data2);
@@ -10462,34 +11161,53 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HAN
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        /* assign_dim has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *value = opline->op2.zv;
-       zval **variable_ptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *value;
+       zval **variable_ptr_ptr;
 
-       if (IS_VAR == IS_VAR && !variable_ptr_ptr) {
+       SAVE_OPLINE();
+       value = opline->op2.zv;
+       variable_ptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(variable_ptr_ptr == NULL)) {
                if (zend_assign_to_string_offset(&EX_T(opline->op1.var), value, IS_CONST TSRMLS_CC)) {
                        if (RETURN_VALUE_USED(opline)) {
-                               EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-                               ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                               INIT_PZVAL(EX_T(opline->result.var).var.ptr);
-                               ZVAL_STRINGL(EX_T(opline->result.var).var.ptr, Z_STRVAL_P(EX_T(opline->op1.var).str_offset.str)+EX_T(opline->op1.var).str_offset.offset, 1, 1);
+                               zval *retval;
+
+                               ALLOC_ZVAL(retval);
+                               ZVAL_STRINGL(retval, Z_STRVAL_P(EX_T(opline->op1.var).str_offset.str)+EX_T(opline->op1.var).str_offset.offset, 1, 1);
+                               INIT_PZVAL(retval);
+                               AI_SET_PTR(&EX_T(opline->result.var), retval);
                        }
                } else if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+               }
+       } else if (IS_VAR == IS_VAR && UNEXPECTED(*variable_ptr_ptr == &EG(error_zval))) {
+               if (0) {
+                       zval_dtor(value);
+               }
+               if (RETURN_VALUE_USED(opline)) {
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
        } else {
-               value = zend_assign_to_variable(variable_ptr_ptr, value, 0 TSRMLS_CC);
+               if (0) {
+                       value = zend_assign_tmp_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+               } else {
+                       value = zend_assign_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+               }
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, value);
                        PZVAL_LOCK(value);
+                       AI_SET_PTR(&EX_T(opline->result.var), value);
                }
        }
 
@@ -10497,38 +11215,42 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER
 
        /* zend_assign_to_variable() always takes care of op2, never free it! */
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        char *function_name_strval;
        int function_name_strlen;
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
        function_name = opline->op2.zv;
 
-       if (Z_TYPE_P(function_name)!=IS_STRING) {
+       if (IS_CONST != IS_CONST &&
+           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                zend_error_noreturn(E_ERROR, "Method name must be a string");
        }
 
        function_name_strval = Z_STRVAL_P(function_name);
        function_name_strlen = Z_STRLEN_P(function_name);
 
-       EX(object) = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       EX(object) = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (EX(object) && Z_TYPE_P(EX(object)) == IS_OBJECT) {
-               if (Z_OBJ_HT_P(EX(object))->get_method == NULL) {
+       if (EXPECTED(EX(object) != NULL) &&
+           EXPECTED(Z_TYPE_P(EX(object)) == IS_OBJECT)) {
+               if (UNEXPECTED(Z_OBJ_HT_P(EX(object))->get_method == NULL)) {
                        zend_error_noreturn(E_ERROR, "Object does not support method calls");
                }
 
                /* First, locate the function. */
                EX(fbc) = Z_OBJ_HT_P(EX(object))->get_method(&EX(object), function_name_strval, function_name_strlen, ((IS_CONST == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
-               if (!EX(fbc)) {
+               if (UNEXPECTED(EX(fbc) == NULL)) {
                        zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", Z_OBJ_CLASS_NAME_P(EX(object)), function_name_strval);
                }
 
@@ -10553,21 +11275,23 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_VAR_CONST_HANDLER(ZEND_OPCO
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        zend_class_entry *ce;
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
        if (IS_VAR == IS_CONST) {
                /* no function found. try a static method in class */
                ce = zend_fetch_class_by_name(Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), opline->op1.literal + 1, opline->extended_value TSRMLS_CC);
-               if (!ce) {
+               if (UNEXPECTED(ce == NULL)) {
                        zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
                }
                EX(called_scope) = ce;
@@ -10591,7 +11315,7 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_CONST_HANDLER(ZE
                } else {
                        function_name = opline->op2.zv;
 
-                       if (Z_TYPE_P(function_name) != IS_STRING) {
+                       if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                                zend_error_noreturn(E_ERROR, "Function name must be a string");
                        } else {
                                function_name_strval = Z_STRVAL_P(function_name);
@@ -10605,7 +11329,7 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_CONST_HANDLER(ZE
                        } else {
                                EX(fbc) = zend_std_get_static_method(ce, function_name_strval, function_name_strlen, ((IS_CONST == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
                        }
-                       if (!EX(fbc)) {
+                       if (UNEXPECTED(EX(fbc) == NULL)) {
                                zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name, function_name_strval);
                        }
                }
@@ -10614,11 +11338,11 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_CONST_HANDLER(ZE
 
                }
        } else {
-               if(!ce->constructor) {
+               if (UNEXPECTED(ce->constructor == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot call constructor");
                }
                if (EG(This) && Z_OBJCE_P(EG(This)) != ce->constructor->common.scope && (ce->constructor->common.fn_flags & ZEND_ACC_PRIVATE)) {
-                       zend_error(E_COMPILE_ERROR, "Cannot call private %s::__construct()", ce->name);
+                       zend_error_noreturn(E_ERROR, "Cannot call private %s::__construct()", ce->name);
                }
                EX(fbc) = ce->constructor;
        }
@@ -10650,15 +11374,17 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_CONST_HANDLER(ZE
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CASE_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        int switch_expr_is_overloaded=0;
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        if (IS_VAR==IS_VAR) {
                if (EX_T(opline->op1.var).var.ptr_ptr) {
                        PZVAL_LOCK(EX_T(opline->op1.var).var.ptr);
@@ -10668,7 +11394,7 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_A
                }
        }
        is_equal_function(&EX_T(opline->result.var).tmp_var,
-                                _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
+                                _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
                                 opline->op2.zv TSRMLS_CC);
 
        if (switch_expr_is_overloaded) {
@@ -10681,13 +11407,15 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_A
                EX_T(opline->op1.var).var.ptr_ptr = NULL;
                EX_T(opline->op1.var).var.ptr = NULL;
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_CONSTANT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
+       SAVE_OPLINE();
        if (IS_VAR == IS_UNUSED) {
                /* namespaced constant */
                if (!zend_get_constant_ex(Z_STRVAL_P(opline->op2.zv), Z_STRLEN_P(opline->op2.zv), &EX_T(opline->result.var).tmp_var, NULL, opline->extended_value TSRMLS_CC)) {
@@ -10702,10 +11430,10 @@ static int ZEND_FASTCALL  ZEND_FETCH_CONSTANT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE
                                zend_error(E_NOTICE, "Use of undefined constant %s - assumed '%s'", actual, actual);
                                ZVAL_STRINGL(&EX_T(opline->result.var).tmp_var, actual, Z_STRLEN_P(opline->op2.zv)-(actual - Z_STRVAL_P(opline->op2.zv)), 1);
                        } else {
-                               zend_error_noreturn(E_ERROR, "Undefined constant '%s'",
-                                                       Z_STRVAL_P(opline->op2.zv), Z_STRVAL_P(opline->op2.zv));
+                               zend_error_noreturn(E_ERROR, "Undefined constant '%s'", Z_STRVAL_P(opline->op2.zv));
                        }
                }
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
                /* class constant */
@@ -10715,14 +11443,14 @@ static int ZEND_FASTCALL  ZEND_FETCH_CONSTANT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE
                if (IS_VAR == IS_CONST) {
 
                        ce = zend_fetch_class_by_name(Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), opline->op1.literal + 1, opline->extended_value TSRMLS_CC);
-                       if (!ce) {
+                       if (UNEXPECTED(ce == NULL)) {
                                zend_error_noreturn(E_ERROR, "Undefined class constant '%s'", Z_STRVAL_P(opline->op2.zv));
                        }
                } else {
                        ce = EX_T(opline->op1.var).class_entry;
                }
 
-               if (zend_hash_quick_find(&ce->constants_table, Z_STRVAL_P(opline->op2.zv), Z_STRLEN_P(opline->op2.zv)+1, Z_HASH_P(opline->op2.zv), (void **) &value) == SUCCESS) {
+               if (EXPECTED(zend_hash_quick_find(&ce->constants_table, Z_STRVAL_P(opline->op2.zv), Z_STRLEN_P(opline->op2.zv)+1, Z_HASH_P(opline->op2.zv), (void **) &value) == SUCCESS)) {
                        if (Z_TYPE_PP(value) == IS_CONSTANT_ARRAY ||
                            (Z_TYPE_PP(value) & IS_CONSTANT_TYPE_MASK) == IS_CONSTANT) {
                                zend_class_entry *old_scope = EG(scope);
@@ -10731,54 +11459,39 @@ static int ZEND_FASTCALL  ZEND_FETCH_CONSTANT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE
                                zval_update_constant(value, (void *) 1 TSRMLS_CC);
                                EG(scope) = old_scope;
                        }
-                       EX_T(opline->result.var).tmp_var = **value;
+                       ZVAL_COPY_VALUE(&EX_T(opline->result.var).tmp_var, *value);
                        zval_copy_ctor(&EX_T(opline->result.var).tmp_var);
                } else {
                        zend_error_noreturn(E_ERROR, "Undefined class constant '%s'", Z_STRVAL_P(opline->op2.zv));
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *array_ptr = &EX_T(opline->result.var).tmp_var;
        zval *expr_ptr;
-       zval *offset=opline->op2.zv;
-       ulong hval;
-       long index;
 
-#if 0 || IS_VAR == IS_VAR || IS_VAR == IS_CV
-       zval **expr_ptr_ptr = NULL;
+       SAVE_OPLINE();
+       if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && opline->extended_value) {
+               zval **expr_ptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (opline->extended_value) {
-               expr_ptr_ptr=_get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
                expr_ptr = *expr_ptr_ptr;
+               Z_ADDREF_P(expr_ptr);
        } else {
-               expr_ptr=_get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       }
-#else
-       expr_ptr=_get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-#endif
-
-       if (0) { /* temporary variable */
-               zval *new_expr;
+               expr_ptr=_get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+               if (0) { /* temporary variable */
+                       zval *new_expr;
 
-               ALLOC_ZVAL(new_expr);
-               INIT_PZVAL_COPY(new_expr, expr_ptr);
-               expr_ptr = new_expr;
-       } else {
-#if 0 || IS_VAR == IS_VAR || IS_VAR == IS_CV
-               if (opline->extended_value) {
-                       SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
-                       expr_ptr = *expr_ptr_ptr;
-                       Z_ADDREF_P(expr_ptr);
-               } else
-#endif
-               if (IS_VAR == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
+                       ALLOC_ZVAL(new_expr);
+                       INIT_PZVAL_COPY(new_expr, expr_ptr);
+                       expr_ptr = new_expr;
+               } else if (IS_VAR == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
                        zval *new_expr;
 
                        ALLOC_ZVAL(new_expr);
@@ -10789,7 +11502,13 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_CONST_HANDLER(ZEND_OPC
                        Z_ADDREF_P(expr_ptr);
                }
        }
-       if (offset) {
+
+       if (IS_CONST != IS_UNUSED) {
+
+               zval *offset = opline->op2.zv;
+               ulong hval;
+               long index;
+
                switch (Z_TYPE_P(offset)) {
                        case IS_DOUBLE:
                                index = zend_dval_to_lval(Z_DVAL_P(offset));
@@ -10798,7 +11517,7 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_CONST_HANDLER(ZEND_OPC
                        case IS_BOOL:
                                index = Z_LVAL_P(offset);
 num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(array_ptr), index, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_index_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), index, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_STRING:
                                if (IS_CONST == IS_CONST) {
@@ -10811,10 +11530,10 @@ num_index:
                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                        }
                                }
-                               zend_hash_quick_update(Z_ARRVAL_P(array_ptr), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_quick_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_NULL:
-                               zend_hash_update(Z_ARRVAL_P(array_ptr), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
                                break;
                        default:
                                zend_error(E_WARNING, "Illegal offset type");
@@ -10824,19 +11543,20 @@ num_index:
                }
 
        } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(array_ptr), &expr_ptr, sizeof(zval *), NULL);
+               zend_hash_next_index_insert(Z_ARRVAL(EX_T(opline->result.var).tmp_var), &expr_ptr, sizeof(zval *), NULL);
        }
-       if (opline->extended_value) {
+       if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && opline->extended_value) {
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        } else {
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (IS_VAR == IS_UNUSED) {
@@ -10850,13 +11570,17 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HAN
 
 static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       zval *offset = opline->op2.zv;
+       zval **container;
+       zval *offset;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       offset = opline->op2.zv;
+
        if (IS_VAR != IS_VAR || container) {
                if (IS_VAR == IS_CV && container != &EG(uninitialized_zval_ptr)) {
                        SEPARATE_ZVAL_IF_NOT_REF(container);
@@ -10890,24 +11614,10 @@ num_index_dim:
                                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                                        }
                                                }
-                                               if (zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval) == SUCCESS &&
-                                           ht == &EG(symbol_table)) {
-                                                       zend_execute_data *ex;
-
-                                                       for (ex = execute_data; ex; ex = ex->prev_execute_data) {
-                                                               if (ex->op_array && ex->symbol_table == ht) {
-                                                                       int i;
-
-                                                                       for (i = 0; i < ex->op_array->last_var; i++) {
-                                                                               if (ex->op_array->vars[i].hash_value == hval &&
-                                                                                   ex->op_array->vars[i].name_len == offset->value.str.len &&
-                                                                                   !memcmp(ex->op_array->vars[i].name, offset->value.str.val, offset->value.str.len)) {
-                                                                                       ex->CVs[i] = NULL;
-                                                                                       break;
-                                                                               }
-                                                                       }
-                                                               }
-                                                       }
+                                               if (ht == &EG(symbol_table)) {
+                                                       zend_delete_global_variable_ex(offset->value.str.val, offset->value.str.len, hval TSRMLS_CC);
+                                               } else {
+                                                       zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval);
                                                }
                                                if (IS_CONST == IS_CV || IS_CONST == IS_VAR) {
                                                        zval_ptr_dtor(&offset);
@@ -10924,7 +11634,7 @@ num_index_dim:
                                break;
                        }
                        case IS_OBJECT:
-                               if (!Z_OBJ_HT_P(*container)->unset_dimension) {
+                               if (UNEXPECTED(Z_OBJ_HT_P(*container)->unset_dimension == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use object as array");
                                }
                                if (0) {
@@ -10949,15 +11659,20 @@ num_index_dim:
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       zval *offset = opline->op2.zv;
+       zval **container;
+       zval *offset;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       offset = opline->op2.zv;
 
        if (IS_VAR != IS_VAR || container) {
                if (IS_VAR == IS_CV && container != &EG(uninitialized_zval_ptr)) {
@@ -10985,19 +11700,23 @@ static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_VAR_CONST_HANDLER(ZEND_OPCODE_HAND
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_isset_isempty_dim_prop_obj_handler_SPEC_VAR_CONST(int prop_dim, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **container;
        zval **value = NULL;
        int result = 0;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
        if (IS_VAR != IS_VAR || container) {
 
                zval *offset = opline->op2.zv;
@@ -11091,7 +11810,7 @@ num_index_prop:
                        zval tmp;
 
                        if (Z_TYPE_P(offset) != IS_LONG) {
-                               tmp = *offset;
+                               ZVAL_COPY_VALUE(&tmp, offset);
                                zval_copy_ctor(&tmp);
                                convert_to_long(&tmp);
                                offset = &tmp;
@@ -11114,15 +11833,15 @@ num_index_prop:
        }
 
        Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
-
        if (opline->extended_value & ZEND_ISSET) {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = result;
-       } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+       } else {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = !result;
        }
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -11138,277 +11857,311 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_CONST_HANDLER(ZEN
 
 static int ZEND_FASTCALL  ZEND_ADD_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        add_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SUB_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        sub_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MUL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        mul_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_DIV_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        div_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MOD_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        mod_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        shift_left_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        shift_right_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        concat_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        is_identical_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        is_identical_function(result,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        Z_LVAL_P(result) = !Z_LVAL_P(result);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) == 0));
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) != 0));
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) < 0));
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) <= 0));
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        bitwise_or_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        bitwise_and_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        bitwise_xor_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        boolean_xor_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op1, free_op2, free_op_data1;
-       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
        zval *object;
-       zval *property = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval *value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
+       zval *property = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       zval *value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
        znode_op *result = &opline->result;
        int have_get_ptr = 0;
 
-       if (IS_VAR == IS_VAR && !object_ptr) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
 
-       EX_T(result->var).var.ptr_ptr = NULL;
        make_real_object(object_ptr TSRMLS_CC);
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to assign property of non-object");
                zval_dtor(free_op2.var);
                FREE_OP(free_op_data1);
 
                if (RETURN_VALUE_USED(opline)) {
-                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                       EX_T(result->var).var.ptr_ptr = NULL;
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                }
        } else {
                /* here we are sure we are dealing with an object */
@@ -11426,9 +12179,9 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(int (*bin
                                have_get_ptr = 1;
                                binary_op(*zptr, *zptr, value TSRMLS_CC);
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = *zptr;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(*zptr);
+                                       EX_T(opline->result.var).var.ptr = *zptr;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -11465,17 +12218,17 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(int (*bin
                                        Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
                                }
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = z;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(z);
+                                       EX_T(opline->result.var).var.ptr = z;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                                zval_ptr_dtor(&z);
                        } else {
                                zend_error(E_WARNING, "Attempt to assign property of non-object");
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                                       EX_T(result->var).var.ptr_ptr = NULL;
-                                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                                       PZVAL_LOCK(&EG(uninitialized_zval));
+                                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -11490,66 +12243,71 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(int (*bin
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2, free_op_data2, free_op_data1;
        zval **var_ptr;
        zval *value;
 
+       SAVE_OPLINE();
        switch (opline->extended_value) {
                case ZEND_ASSIGN_OBJ:
                        return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                        break;
                case ZEND_ASSIGN_DIM: {
-                               zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+                               zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-                               if (IS_VAR == IS_VAR && !container) {
+                               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-                               } else if (Z_TYPE_PP(container) == IS_OBJECT) {
+                               } else if (UNEXPECTED(Z_TYPE_PP(container) == IS_OBJECT)) {
                                        if (IS_VAR == IS_VAR && !(free_op1.var != NULL)) {
                                                Z_ADDREF_PP(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
                                        }
                                        return zend_binary_assign_op_obj_helper_SPEC_VAR_TMP(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                                } else {
-                                       zend_op *op_data = opline+1;
-                                       zval *dim = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+                                       zval *dim = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
-                                       zend_fetch_dimension_address(&EX_T(op_data->op2.var), container, dim, IS_TMP_VAR, BP_VAR_RW TSRMLS_CC);
-                                       value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-                                       var_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-                                       ZEND_VM_INC_OPCODE();
+                                       zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), container, dim, IS_TMP_VAR, BP_VAR_RW TSRMLS_CC);
+                                       value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+                                       var_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
                                }
                        }
                        break;
                default:
-                       value = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-                       var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+                       value = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+                       var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
                        /* do nothing */
                        break;
        }
 
-       if (!var_ptr) {
+       if (UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
        }
 
-       if (*var_ptr == EG(error_zval_ptr)) {
+       if (UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
                zval_dtor(free_op2.var);
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
+               if (opline->extended_value == ZEND_ASSIGN_DIM) {
+                       ZEND_VM_INC_OPCODE();
+               }
                ZEND_VM_NEXT_OPCODE();
        }
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *objval = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -11562,16 +12320,21 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_TMP(int (*binary_
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *var_ptr);
                PZVAL_LOCK(*var_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *var_ptr);
        }
        zval_dtor(free_op2.var);
 
        if (opline->extended_value == ZEND_ASSIGN_DIM) {
                FREE_OP(free_op_data1);
                FREE_OP_VAR_PTR(free_op_data2);
+               if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
+               ZEND_VM_INC_OPCODE();
+       } else {
+               if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
        }
-       if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -11632,29 +12395,35 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HA
 
 static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_TMP(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **object_ptr;
        zval *object;
-       zval *property = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **retval = &EX_T(opline->result.var).var.ptr;
+       zval *property;
+       zval **retval;
        int have_get_ptr = 0;
 
-       if (IS_VAR == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       property = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       retval = &EX_T(opline->result.var).var.ptr;
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                zval_dtor(free_op2.var);
                if (RETURN_VALUE_USED(opline)) {
-                       *retval = EG(uninitialized_zval_ptr);
-                       PZVAL_LOCK(*retval);
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       *retval = &EG(uninitialized_zval);
                }
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -11682,7 +12451,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_TMP(incdec_t i
                if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -11702,8 +12471,8 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_TMP(incdec_t i
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                        if (RETURN_VALUE_USED(opline)) {
-                               *retval = EG(uninitialized_zval_ptr);
-                               PZVAL_LOCK(*retval);
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               *retval = &EG(uninitialized_zval);
                        }
                }
        }
@@ -11714,6 +12483,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_TMP(incdec_t i
                zval_dtor(free_op2.var);
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -11729,26 +12499,32 @@ static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HAND
 
 static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_TMP(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **object_ptr;
        zval *object;
-       zval *property = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval *retval = &EX_T(opline->result.var).tmp_var;
+       zval *property;
+       zval *retval;
        int have_get_ptr = 0;
 
-       if (IS_VAR == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       property = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       retval = &EX_T(opline->result.var).tmp_var;
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                zval_dtor(free_op2.var);
-               *retval = *EG(uninitialized_zval_ptr);
+               ZVAL_NULL(retval);
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -11764,7 +12540,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_TMP(incdec_t
                        have_get_ptr = 1;
                        SEPARATE_ZVAL_IF_NOT_REF(zptr);
 
-                       *retval = **zptr;
+                       ZVAL_COPY_VALUE(retval, *zptr);
                        zendi_zval_copy_ctor(*retval);
 
                        incdec_op(*zptr);
@@ -11777,7 +12553,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_TMP(incdec_t
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
                        zval *z_copy;
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -11787,12 +12563,11 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_TMP(incdec_t
                                }
                                z = value;
                        }
-                       *retval = *z;
+                       ZVAL_COPY_VALUE(retval, z);
                        zendi_zval_copy_ctor(*retval);
                        ALLOC_ZVAL(z_copy);
-                       *z_copy = *z;
+                       INIT_PZVAL_COPY(z_copy, z);
                        zendi_zval_copy_ctor(*z_copy);
-                       INIT_PZVAL(z_copy);
                        incdec_op(z_copy);
                        Z_ADDREF_P(z);
                        Z_OBJ_HT_P(object)->write_property(object, property, z_copy, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
@@ -11800,7 +12575,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_TMP(incdec_t
                        zval_ptr_dtor(&z);
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-                       *retval = *EG(uninitialized_zval_ptr);
+                       ZVAL_NULL(retval);
                }
        }
 
@@ -11810,6 +12585,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_TMP(incdec_t
                zval_dtor(free_op2.var);
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -11825,195 +12601,194 @@ static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HAN
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *dim = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
        zval **container;
 
+       SAVE_OPLINE();
+
        if ((opline->extended_value & ZEND_FETCH_ADD_LOCK) &&
            IS_VAR != IS_CV &&
            EX_T(opline->op1.var).var.ptr_ptr) {
                PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
        }
-       container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       if (IS_VAR == IS_VAR && !container) {
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address_read(!RETURN_VALUE_USED(opline)?NULL:&EX_T(opline->result.var), container, dim, IS_TMP_VAR, BP_VAR_R TSRMLS_CC);
+       zend_fetch_dimension_address_read(!RETURN_VALUE_USED(opline)?NULL:&EX_T(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_TMP_VAR, BP_VAR_R TSRMLS_CC);
        zval_dtor(free_op2.var);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *dim = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **container;
 
-       if (IS_VAR == IS_VAR && !container) {
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_TMP_VAR, BP_VAR_W TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_TMP_VAR, BP_VAR_W TSRMLS_CC);
        zval_dtor(free_op2.var);
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
        /* We are going to assign the result by reference */
-       if (opline->extended_value && EX_T(opline->result.var).var.ptr_ptr) {
-               Z_DELREF_PP(EX_T(opline->result.var).var.ptr_ptr);
-               SEPARATE_ZVAL_TO_MAKE_IS_REF(EX_T(opline->result.var).var.ptr_ptr);
-               Z_ADDREF_PP(EX_T(opline->result.var).var.ptr_ptr);
+       if (UNEXPECTED(opline->extended_value != 0)) {
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+
+               if (retval_ptr) {
+                       Z_DELREF_PP(retval_ptr);
+                       SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
+                       Z_ADDREF_PP(retval_ptr);
+               }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *dim = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **container;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (IS_VAR == IS_VAR && !container) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_TMP_VAR, BP_VAR_RW TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_TMP_VAR, BP_VAR_RW TSRMLS_CC);
        zval_dtor(free_op2.var);
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *dim = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **container;
 
-       if (IS_VAR == IS_VAR && !container) {
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, dim, IS_TMP_VAR, BP_VAR_IS TSRMLS_CC);
+       zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_TMP_VAR, BP_VAR_IS TSRMLS_CC);
        zval_dtor(free_op2.var);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *dim = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
        zval **container;
 
+       SAVE_OPLINE();
+
        if (ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))) {
-               container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-               if (IS_VAR == IS_VAR && !container) {
+               container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_TMP_VAR, BP_VAR_W TSRMLS_CC);
-               if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-                   READY_TO_DESTROY(free_op1.var)) {
-                       AI_USE_PTR(EX_T(opline->result.var).var);
-                       if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                           Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                               SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-                       }
+               zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_TMP_VAR, BP_VAR_W TSRMLS_CC);
+               if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+                       EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
                }
        } else {
                if (IS_TMP_VAR == IS_UNUSED) {
                        zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
                }
-               container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-               if (IS_VAR == IS_VAR && !container) {
+               container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, dim, IS_TMP_VAR, BP_VAR_R TSRMLS_CC);
+               zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_TMP_VAR, BP_VAR_R TSRMLS_CC);
        }
        zval_dtor(free_op2.var);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_UNSET_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       zval *dim = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **container;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       /* Not needed in DIM_UNSET
-       if (opline->extended_value & ZEND_FETCH_ADD_LOCK) {
-               PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
-       }
-       */
        if (IS_VAR == IS_CV) {
                if (container != &EG(uninitialized_zval_ptr)) {
                        SEPARATE_ZVAL_IF_NOT_REF(container);
                }
        }
-       if (IS_VAR == IS_VAR && !container) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_TMP_VAR, BP_VAR_UNSET TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_TMP_VAR, BP_VAR_UNSET TSRMLS_CC);
        zval_dtor(free_op2.var);
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
-       if (EX_T(opline->result.var).var.ptr_ptr == NULL) {
+       if (UNEXPECTED(EX_T(opline->result.var).var.ptr_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
        } else {
                zend_free_op free_res;
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
 
-               PZVAL_UNLOCK(*EX_T(opline->result.var).var.ptr_ptr, &free_res);
-               if (EX_T(opline->result.var).var.ptr_ptr != &EG(uninitialized_zval_ptr)) {
-                       SEPARATE_ZVAL_IF_NOT_REF(EX_T(opline->result.var).var.ptr_ptr);
+               PZVAL_UNLOCK(*retval_ptr, &free_res);
+               if (retval_ptr != &EG(uninitialized_zval_ptr)) {
+                       SEPARATE_ZVAL_IF_NOT_REF(retval_ptr);
                }
-               PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
+               PZVAL_LOCK(*retval_ptr);
                FREE_OP_VAR_PTR(free_res);
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
        }
-       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_VAR_TMP(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_VAR_TMP(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *container = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *container;
        zend_free_op free_op2;
-       zval *offset  = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval *offset;
 
-       if (Z_TYPE_P(container) != IS_OBJECT || !Z_OBJ_HT_P(container)->read_property) {
-               if (type != BP_VAR_IS) {
-                       zend_error(E_NOTICE, "Trying to get property of non-object");
-               }
+       SAVE_OPLINE();
+       container = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       offset  = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               zend_error(E_NOTICE, "Trying to get property of non-object");
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
                zval_dtor(free_op2.var);
        } else {
@@ -12024,7 +12799,7 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_VAR_TMP(in
                }
 
                /* here we are sure we are dealing with an object */
-               retval = Z_OBJ_HT_P(container)->read_property(container, offset, type, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
                if (!RETURN_VALUE_USED(opline)) {
                        if (Z_REFCOUNT_P(retval) == 0) {
@@ -12033,8 +12808,8 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_VAR_TMP(in
                                FREE_ZVAL(retval);
                        }
                } else {
-                       AI_SET_PTR(EX_T(opline->result.var).var, retval);
                        PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                }
 
                if (1) {
@@ -12045,21 +12820,25 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_VAR_TMP(in
        }
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_property_address_read_helper_SPEC_VAR_TMP(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_fetch_property_address_read_helper_SPEC_VAR_TMP(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *property = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval *property;
        zval **container;
 
+       SAVE_OPLINE();
+       property = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
        if (IS_VAR == IS_VAR && (opline->extended_value & ZEND_FETCH_ADD_LOCK)) {
                PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
                EX_T(opline->op1.var).var.ptr = *EX_T(opline->op1.var).var.ptr_ptr;
@@ -12068,47 +12847,50 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HAND
        if (1) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       if (IS_VAR == IS_VAR && !container) {
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
+
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
        if (1) {
                zval_ptr_dtor(&property);
        } else {
                zval_dtor(free_op2.var);
        }
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
        /* We are going to assign the result by reference */
        if (opline->extended_value & ZEND_FETCH_MAKE_REF) {
-               Z_DELREF_PP(EX_T(opline->result.var).var.ptr_ptr);
-               SEPARATE_ZVAL_TO_MAKE_IS_REF(EX_T(opline->result.var).var.ptr_ptr);
-               Z_ADDREF_PP(EX_T(opline->result.var).var.ptr_ptr);
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+
+               Z_DELREF_PP(retval_ptr);
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
+               Z_ADDREF_PP(retval_ptr);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *property = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *property;
+       zval **container;
+
+       SAVE_OPLINE();
+       property = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
        if (1) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       if (IS_VAR == IS_VAR && !container) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_RW TSRMLS_CC);
@@ -12117,37 +12899,84 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HAN
        } else {
                zval_dtor(free_op2.var);
        }
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_property_address_read_helper_SPEC_VAR_TMP(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *container;
+       zend_free_op free_op2;
+       zval *offset;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       offset  = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               if (RETURN_VALUE_USED(opline)) {
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+               }
+               zval_dtor(free_op2.var);
+       } else {
+               zval *retval;
+
+               if (1) {
+                       MAKE_REAL_ZVAL_PTR(offset);
+               }
+
+               /* here we are sure we are dealing with an object */
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+
+               if (!RETURN_VALUE_USED(opline)) {
+                       if (Z_REFCOUNT_P(retval) == 0) {
+                               GC_REMOVE_ZVAL_FROM_BUFFER(retval);
+                               zval_dtor(retval);
+                               FREE_ZVAL(retval);
+                       }
+               } else {
+                       PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
+               }
+
+               if (1) {
+                       zval_ptr_dtor(&offset);
+               } else {
+                       zval_dtor(free_op2.var);
+               }
+       }
+
+       if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        if (ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))) {
                /* Behave like FETCH_OBJ_W */
                zend_free_op free_op1, free_op2;
-               zval *property = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-               zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+               zval *property;
+               zval **container;
+
+               SAVE_OPLINE();
+               property = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+               container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
                if (1) {
                        MAKE_REAL_ZVAL_PTR(property);
                }
-               if (IS_VAR == IS_VAR && !container) {
+               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
                }
                zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
@@ -12156,27 +12985,27 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_TMP_HANDLER(ZEND_OPCO
                } else {
                        zval_dtor(free_op2.var);
                }
-               if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-                   READY_TO_DESTROY(free_op1.var)) {
-                       AI_USE_PTR(EX_T(opline->result.var).var);
-                       if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                           Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                               SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-                       }
+               if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+                       EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
                }
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
-               return zend_fetch_property_address_read_helper_SPEC_VAR_TMP(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_fetch_property_address_read_helper_SPEC_VAR_TMP(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2, free_res;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       zval *property = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **container;
+       zval *property;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       property = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
        if (IS_VAR == IS_CV) {
                if (container != &EG(uninitialized_zval_ptr)) {
@@ -12186,7 +13015,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_
        if (1) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       if (IS_VAR == IS_VAR && !container) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_UNSET TSRMLS_CC);
@@ -12195,13 +13024,8 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_
        } else {
                zval_dtor(free_op2.var);
        }
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
@@ -12211,24 +13035,28 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_
        }
        PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
        FREE_OP_VAR_PTR(free_res);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       zval *property_name = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **object_ptr;
+       zval *property_name;
+
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       property_name = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
        if (1) {
                MAKE_REAL_ZVAL_PTR(property_name);
        }
-       if (IS_VAR == IS_VAR && !object_ptr) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, op_data->op1_type, &op_data->op1, EX(Ts), ZEND_ASSIGN_OBJ, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), ZEND_ASSIGN_OBJ, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
        if (1) {
                zval_ptr_dtor(&property_name);
        } else {
@@ -12236,28 +13064,31 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDL
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **object_ptr;
 
-       if (IS_VAR == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
        if (Z_TYPE_PP(object_ptr) == IS_OBJECT) {
                zend_free_op free_op2;
-               zval *property_name = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+               zval *property_name = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
                if (1) {
                        MAKE_REAL_ZVAL_PTR(property_name);
                }
-               zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, op_data->op1_type, &op_data->op1, EX(Ts), ZEND_ASSIGN_DIM, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+               zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), ZEND_ASSIGN_DIM, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
                if (1) {
                        zval_ptr_dtor(&property_name);
                } else {
@@ -12266,31 +13097,45 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDL
        } else {
                zend_free_op free_op2, free_op_data1, free_op_data2;
                zval *value;
-               zval *dim = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+               zval *dim = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
                zval **variable_ptr_ptr;
 
-               zend_fetch_dimension_address(&EX_T(op_data->op2.var), object_ptr, dim, IS_TMP_VAR, BP_VAR_W TSRMLS_CC);
+               zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), object_ptr, dim, IS_TMP_VAR, BP_VAR_W TSRMLS_CC);
                zval_dtor(free_op2.var);
 
-               value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-               variable_ptr_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-               if (!variable_ptr_ptr) {
-                       if (zend_assign_to_string_offset(&EX_T(op_data->op2.var), value, op_data->op1_type TSRMLS_CC)) {
+               value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+               variable_ptr_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
+               if (UNEXPECTED(variable_ptr_ptr == NULL)) {
+                       if (zend_assign_to_string_offset(&EX_T((opline+1)->op2.var), value, (opline+1)->op1_type TSRMLS_CC)) {
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-                                       ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                                       INIT_PZVAL(EX_T(opline->result.var).var.ptr);
-                                       ZVAL_STRINGL(EX_T(opline->result.var).var.ptr, Z_STRVAL_P(EX_T(op_data->op2.var).str_offset.str)+EX_T(op_data->op2.var).str_offset.offset, 1, 1);
+                                       zval *retval;
+
+                                       ALLOC_ZVAL(retval);
+                                       ZVAL_STRINGL(retval, Z_STRVAL_P(EX_T((opline+1)->op2.var).str_offset.str)+EX_T((opline+1)->op2.var).str_offset.offset, 1, 1);
+                                       INIT_PZVAL(retval);
+                                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                                }
                        } else if (RETURN_VALUE_USED(opline)) {
-                               AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                               PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+                       }
+               } else if (UNEXPECTED(*variable_ptr_ptr == &EG(error_zval))) {
+                       if (IS_TMP_FREE(free_op_data1)) {
+                               zval_dtor(value);
+                       }
+                       if (RETURN_VALUE_USED(opline)) {
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                        }
                } else {
-                       value = zend_assign_to_variable(variable_ptr_ptr, value, IS_TMP_FREE(free_op_data1) TSRMLS_CC);
+                       if (IS_TMP_FREE(free_op_data1)) {
+                               value = zend_assign_tmp_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+                       } else {
+                               value = zend_assign_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+                       }
                        if (RETURN_VALUE_USED(opline)) {
-                               AI_SET_PTR(EX_T(opline->result.var).var, value);
                                PZVAL_LOCK(value);
+                               AI_SET_PTR(&EX_T(opline->result.var), value);
                        }
                }
                FREE_OP_VAR_PTR(free_op_data2);
@@ -12298,34 +13143,53 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDL
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        /* assign_dim has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *value = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **variable_ptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *value;
+       zval **variable_ptr_ptr;
+
+       SAVE_OPLINE();
+       value = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       variable_ptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (IS_VAR == IS_VAR && !variable_ptr_ptr) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(variable_ptr_ptr == NULL)) {
                if (zend_assign_to_string_offset(&EX_T(opline->op1.var), value, IS_TMP_VAR TSRMLS_CC)) {
                        if (RETURN_VALUE_USED(opline)) {
-                               EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-                               ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                               INIT_PZVAL(EX_T(opline->result.var).var.ptr);
-                               ZVAL_STRINGL(EX_T(opline->result.var).var.ptr, Z_STRVAL_P(EX_T(opline->op1.var).str_offset.str)+EX_T(opline->op1.var).str_offset.offset, 1, 1);
+                               zval *retval;
+
+                               ALLOC_ZVAL(retval);
+                               ZVAL_STRINGL(retval, Z_STRVAL_P(EX_T(opline->op1.var).str_offset.str)+EX_T(opline->op1.var).str_offset.offset, 1, 1);
+                               INIT_PZVAL(retval);
+                               AI_SET_PTR(&EX_T(opline->result.var), retval);
                        }
                } else if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+               }
+       } else if (IS_VAR == IS_VAR && UNEXPECTED(*variable_ptr_ptr == &EG(error_zval))) {
+               if (1) {
+                       zval_dtor(value);
+               }
+               if (RETURN_VALUE_USED(opline)) {
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
        } else {
-               value = zend_assign_to_variable(variable_ptr_ptr, value, 1 TSRMLS_CC);
+               if (1) {
+                       value = zend_assign_tmp_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+               } else {
+                       value = zend_assign_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+               }
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, value);
                        PZVAL_LOCK(value);
+                       AI_SET_PTR(&EX_T(opline->result.var), value);
                }
        }
 
@@ -12333,38 +13197,42 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_A
 
        /* zend_assign_to_variable() always takes care of op2, never free it! */
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        char *function_name_strval;
        int function_name_strlen;
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
-       function_name = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       function_name = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
-       if (Z_TYPE_P(function_name)!=IS_STRING) {
+       if (IS_TMP_VAR != IS_CONST &&
+           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                zend_error_noreturn(E_ERROR, "Method name must be a string");
        }
 
        function_name_strval = Z_STRVAL_P(function_name);
        function_name_strlen = Z_STRLEN_P(function_name);
 
-       EX(object) = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       EX(object) = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (EX(object) && Z_TYPE_P(EX(object)) == IS_OBJECT) {
-               if (Z_OBJ_HT_P(EX(object))->get_method == NULL) {
+       if (EXPECTED(EX(object) != NULL) &&
+           EXPECTED(Z_TYPE_P(EX(object)) == IS_OBJECT)) {
+               if (UNEXPECTED(Z_OBJ_HT_P(EX(object))->get_method == NULL)) {
                        zend_error_noreturn(E_ERROR, "Object does not support method calls");
                }
 
                /* First, locate the function. */
                EX(fbc) = Z_OBJ_HT_P(EX(object))->get_method(&EX(object), function_name_strval, function_name_strlen, ((IS_TMP_VAR == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
-               if (!EX(fbc)) {
+               if (UNEXPECTED(EX(fbc) == NULL)) {
                        zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", Z_OBJ_CLASS_NAME_P(EX(object)), function_name_strval);
                }
 
@@ -12390,21 +13258,23 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE
        zval_dtor(free_op2.var);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        zend_class_entry *ce;
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
        if (IS_VAR == IS_CONST) {
                /* no function found. try a static method in class */
                ce = zend_fetch_class_by_name(Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), opline->op1.literal + 1, opline->extended_value TSRMLS_CC);
-               if (!ce) {
+               if (UNEXPECTED(ce == NULL)) {
                        zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
                }
                EX(called_scope) = ce;
@@ -12426,9 +13296,9 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_TMP_HANDLER(ZEND
                        function_name_strval = Z_STRVAL_P(opline->op2.zv);
                        function_name_strlen = Z_STRLEN_P(opline->op2.zv);
                } else {
-                       function_name = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+                       function_name = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
-                       if (Z_TYPE_P(function_name) != IS_STRING) {
+                       if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                                zend_error_noreturn(E_ERROR, "Function name must be a string");
                        } else {
                                function_name_strval = Z_STRVAL_P(function_name);
@@ -12442,7 +13312,7 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_TMP_HANDLER(ZEND
                        } else {
                                EX(fbc) = zend_std_get_static_method(ce, function_name_strval, function_name_strlen, ((IS_TMP_VAR == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
                        }
-                       if (!EX(fbc)) {
+                       if (UNEXPECTED(EX(fbc) == NULL)) {
                                zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name, function_name_strval);
                        }
                }
@@ -12451,11 +13321,11 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_TMP_HANDLER(ZEND
                        zval_dtor(free_op2.var);
                }
        } else {
-               if(!ce->constructor) {
+               if (UNEXPECTED(ce->constructor == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot call constructor");
                }
                if (EG(This) && Z_OBJCE_P(EG(This)) != ce->constructor->common.scope && (ce->constructor->common.fn_flags & ZEND_ACC_PRIVATE)) {
-                       zend_error(E_COMPILE_ERROR, "Cannot call private %s::__construct()", ce->name);
+                       zend_error_noreturn(E_ERROR, "Cannot call private %s::__construct()", ce->name);
                }
                EX(fbc) = ce->constructor;
        }
@@ -12487,15 +13357,17 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_TMP_HANDLER(ZEND
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CASE_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        int switch_expr_is_overloaded=0;
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        if (IS_VAR==IS_VAR) {
                if (EX_T(opline->op1.var).var.ptr_ptr) {
                        PZVAL_LOCK(EX_T(opline->op1.var).var.ptr);
@@ -12505,8 +13377,8 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARG
                }
        }
        is_equal_function(&EX_T(opline->result.var).tmp_var,
-                                _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-                                _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+                                _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+                                _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
        if (switch_expr_is_overloaded) {
@@ -12519,47 +13391,32 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARG
                EX_T(opline->op1.var).var.ptr_ptr = NULL;
                EX_T(opline->op1.var).var.ptr = NULL;
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_free_op free_op1, free_op2;
-       zval *array_ptr = &EX_T(opline->result.var).tmp_var;
+       USE_OPLINE
+       zend_free_op free_op1;
        zval *expr_ptr;
-       zval *offset=_get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       ulong hval;
-       long index;
 
-#if 0 || IS_VAR == IS_VAR || IS_VAR == IS_CV
-       zval **expr_ptr_ptr = NULL;
+       SAVE_OPLINE();
+       if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && opline->extended_value) {
+               zval **expr_ptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (opline->extended_value) {
-               expr_ptr_ptr=_get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
                expr_ptr = *expr_ptr_ptr;
+               Z_ADDREF_P(expr_ptr);
        } else {
-               expr_ptr=_get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       }
-#else
-       expr_ptr=_get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-#endif
-
-       if (0) { /* temporary variable */
-               zval *new_expr;
+               expr_ptr=_get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+               if (0) { /* temporary variable */
+                       zval *new_expr;
 
-               ALLOC_ZVAL(new_expr);
-               INIT_PZVAL_COPY(new_expr, expr_ptr);
-               expr_ptr = new_expr;
-       } else {
-#if 0 || IS_VAR == IS_VAR || IS_VAR == IS_CV
-               if (opline->extended_value) {
-                       SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
-                       expr_ptr = *expr_ptr_ptr;
-                       Z_ADDREF_P(expr_ptr);
-               } else
-#endif
-               if (IS_VAR == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
+                       ALLOC_ZVAL(new_expr);
+                       INIT_PZVAL_COPY(new_expr, expr_ptr);
+                       expr_ptr = new_expr;
+               } else if (IS_VAR == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
                        zval *new_expr;
 
                        ALLOC_ZVAL(new_expr);
@@ -12570,7 +13427,13 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_TMP_HANDLER(ZEND_OPCOD
                        Z_ADDREF_P(expr_ptr);
                }
        }
-       if (offset) {
+
+       if (IS_TMP_VAR != IS_UNUSED) {
+               zend_free_op free_op2;
+               zval *offset = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+               ulong hval;
+               long index;
+
                switch (Z_TYPE_P(offset)) {
                        case IS_DOUBLE:
                                index = zend_dval_to_lval(Z_DVAL_P(offset));
@@ -12579,7 +13442,7 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_TMP_HANDLER(ZEND_OPCOD
                        case IS_BOOL:
                                index = Z_LVAL_P(offset);
 num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(array_ptr), index, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_index_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), index, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_STRING:
                                if (IS_TMP_VAR == IS_CONST) {
@@ -12592,10 +13455,10 @@ num_index:
                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                        }
                                }
-                               zend_hash_quick_update(Z_ARRVAL_P(array_ptr), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_quick_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_NULL:
-                               zend_hash_update(Z_ARRVAL_P(array_ptr), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
                                break;
                        default:
                                zend_error(E_WARNING, "Illegal offset type");
@@ -12605,19 +13468,20 @@ num_index:
                }
                zval_dtor(free_op2.var);
        } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(array_ptr), &expr_ptr, sizeof(zval *), NULL);
+               zend_hash_next_index_insert(Z_ARRVAL(EX_T(opline->result.var).tmp_var), &expr_ptr, sizeof(zval *), NULL);
        }
-       if (opline->extended_value) {
+       if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && opline->extended_value) {
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        } else {
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (IS_VAR == IS_UNUSED) {
@@ -12631,13 +13495,17 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDL
 
 static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       zval *offset = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **container;
+       zval *offset;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       offset = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
        if (IS_VAR != IS_VAR || container) {
                if (IS_VAR == IS_CV && container != &EG(uninitialized_zval_ptr)) {
                        SEPARATE_ZVAL_IF_NOT_REF(container);
@@ -12671,24 +13539,10 @@ num_index_dim:
                                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                                        }
                                                }
-                                               if (zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval) == SUCCESS &&
-                                           ht == &EG(symbol_table)) {
-                                                       zend_execute_data *ex;
-
-                                                       for (ex = execute_data; ex; ex = ex->prev_execute_data) {
-                                                               if (ex->op_array && ex->symbol_table == ht) {
-                                                                       int i;
-
-                                                                       for (i = 0; i < ex->op_array->last_var; i++) {
-                                                                               if (ex->op_array->vars[i].hash_value == hval &&
-                                                                                   ex->op_array->vars[i].name_len == offset->value.str.len &&
-                                                                                   !memcmp(ex->op_array->vars[i].name, offset->value.str.val, offset->value.str.len)) {
-                                                                                       ex->CVs[i] = NULL;
-                                                                                       break;
-                                                                               }
-                                                                       }
-                                                               }
-                                                       }
+                                               if (ht == &EG(symbol_table)) {
+                                                       zend_delete_global_variable_ex(offset->value.str.val, offset->value.str.len, hval TSRMLS_CC);
+                                               } else {
+                                                       zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval);
                                                }
                                                if (IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) {
                                                        zval_ptr_dtor(&offset);
@@ -12705,7 +13559,7 @@ num_index_dim:
                                break;
                        }
                        case IS_OBJECT:
-                               if (!Z_OBJ_HT_P(*container)->unset_dimension) {
+                               if (UNEXPECTED(Z_OBJ_HT_P(*container)->unset_dimension == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use object as array");
                                }
                                if (1) {
@@ -12730,15 +13584,20 @@ num_index_dim:
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       zval *offset = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **container;
+       zval *offset;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       offset = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
        if (IS_VAR != IS_VAR || container) {
                if (IS_VAR == IS_CV && container != &EG(uninitialized_zval_ptr)) {
@@ -12766,22 +13625,26 @@ static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_OPCODE_HANDLE
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_isset_isempty_dim_prop_obj_handler_SPEC_VAR_TMP(int prop_dim, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **container;
        zval **value = NULL;
        int result = 0;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
        if (IS_VAR != IS_VAR || container) {
                zend_free_op free_op2;
-               zval *offset = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+               zval *offset = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
                if (Z_TYPE_PP(container) == IS_ARRAY && !prop_dim) {
                        HashTable *ht;
@@ -12872,7 +13735,7 @@ num_index_prop:
                        zval tmp;
 
                        if (Z_TYPE_P(offset) != IS_LONG) {
-                               tmp = *offset;
+                               ZVAL_COPY_VALUE(&tmp, offset);
                                zval_copy_ctor(&tmp);
                                convert_to_long(&tmp);
                                offset = &tmp;
@@ -12895,15 +13758,15 @@ num_index_prop:
        }
 
        Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
-
        if (opline->extended_value & ZEND_ISSET) {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = result;
-       } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+       } else {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = !result;
        }
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -12919,277 +13782,311 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_TMP_HANDLER(ZEND_
 
 static int ZEND_FASTCALL  ZEND_ADD_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        add_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SUB_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        sub_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MUL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        mul_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_DIV_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        div_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MOD_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        mod_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        shift_left_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        shift_right_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        concat_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        is_identical_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        is_identical_function(result,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        Z_LVAL_P(result) = !Z_LVAL_P(result);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) == 0));
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) != 0));
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) < 0));
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) <= 0));
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        bitwise_or_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        bitwise_and_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        bitwise_xor_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        boolean_xor_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op1, free_op2, free_op_data1;
-       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
        zval *object;
-       zval *property = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval *value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
+       zval *property = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       zval *value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
        znode_op *result = &opline->result;
        int have_get_ptr = 0;
 
-       if (IS_VAR == IS_VAR && !object_ptr) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
 
-       EX_T(result->var).var.ptr_ptr = NULL;
        make_real_object(object_ptr TSRMLS_CC);
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to assign property of non-object");
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
                FREE_OP(free_op_data1);
 
                if (RETURN_VALUE_USED(opline)) {
-                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                       EX_T(result->var).var.ptr_ptr = NULL;
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                }
        } else {
                /* here we are sure we are dealing with an object */
@@ -13207,9 +14104,9 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(int (*bin
                                have_get_ptr = 1;
                                binary_op(*zptr, *zptr, value TSRMLS_CC);
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = *zptr;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(*zptr);
+                                       EX_T(opline->result.var).var.ptr = *zptr;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -13246,17 +14143,17 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(int (*bin
                                        Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
                                }
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = z;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(z);
+                                       EX_T(opline->result.var).var.ptr = z;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                                zval_ptr_dtor(&z);
                        } else {
                                zend_error(E_WARNING, "Attempt to assign property of non-object");
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                                       EX_T(result->var).var.ptr_ptr = NULL;
-                                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                                       PZVAL_LOCK(&EG(uninitialized_zval));
+                                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -13271,66 +14168,71 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(int (*bin
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2, free_op_data2, free_op_data1;
        zval **var_ptr;
        zval *value;
 
+       SAVE_OPLINE();
        switch (opline->extended_value) {
                case ZEND_ASSIGN_OBJ:
                        return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                        break;
                case ZEND_ASSIGN_DIM: {
-                               zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+                               zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-                               if (IS_VAR == IS_VAR && !container) {
+                               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-                               } else if (Z_TYPE_PP(container) == IS_OBJECT) {
+                               } else if (UNEXPECTED(Z_TYPE_PP(container) == IS_OBJECT)) {
                                        if (IS_VAR == IS_VAR && !(free_op1.var != NULL)) {
                                                Z_ADDREF_PP(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
                                        }
                                        return zend_binary_assign_op_obj_helper_SPEC_VAR_VAR(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                                } else {
-                                       zend_op *op_data = opline+1;
-                                       zval *dim = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+                                       zval *dim = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
-                                       zend_fetch_dimension_address(&EX_T(op_data->op2.var), container, dim, IS_VAR, BP_VAR_RW TSRMLS_CC);
-                                       value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-                                       var_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-                                       ZEND_VM_INC_OPCODE();
+                                       zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), container, dim, IS_VAR, BP_VAR_RW TSRMLS_CC);
+                                       value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+                                       var_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
                                }
                        }
                        break;
                default:
-                       value = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-                       var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+                       value = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+                       var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
                        /* do nothing */
                        break;
        }
 
-       if (!var_ptr) {
+       if (UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
        }
 
-       if (*var_ptr == EG(error_zval_ptr)) {
+       if (UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
+               if (opline->extended_value == ZEND_ASSIGN_DIM) {
+                       ZEND_VM_INC_OPCODE();
+               }
                ZEND_VM_NEXT_OPCODE();
        }
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *objval = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -13343,16 +14245,21 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_VAR(int (*binary_
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *var_ptr);
                PZVAL_LOCK(*var_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *var_ptr);
        }
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
 
        if (opline->extended_value == ZEND_ASSIGN_DIM) {
                FREE_OP(free_op_data1);
                FREE_OP_VAR_PTR(free_op_data2);
+               if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
+               ZEND_VM_INC_OPCODE();
+       } else {
+               if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
        }
-       if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -13413,29 +14320,35 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HA
 
 static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_VAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **object_ptr;
        zval *object;
-       zval *property = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **retval = &EX_T(opline->result.var).var.ptr;
+       zval *property;
+       zval **retval;
        int have_get_ptr = 0;
 
-       if (IS_VAR == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       property = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       retval = &EX_T(opline->result.var).var.ptr;
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
                if (RETURN_VALUE_USED(opline)) {
-                       *retval = EG(uninitialized_zval_ptr);
-                       PZVAL_LOCK(*retval);
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       *retval = &EG(uninitialized_zval);
                }
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -13463,7 +14376,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_VAR(incdec_t i
                if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -13483,8 +14396,8 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_VAR(incdec_t i
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                        if (RETURN_VALUE_USED(opline)) {
-                               *retval = EG(uninitialized_zval_ptr);
-                               PZVAL_LOCK(*retval);
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               *retval = &EG(uninitialized_zval);
                        }
                }
        }
@@ -13495,6 +14408,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_VAR(incdec_t i
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -13510,26 +14424,32 @@ static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HAND
 
 static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_VAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **object_ptr;
        zval *object;
-       zval *property = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval *retval = &EX_T(opline->result.var).tmp_var;
+       zval *property;
+       zval *retval;
        int have_get_ptr = 0;
 
-       if (IS_VAR == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       property = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       retval = &EX_T(opline->result.var).tmp_var;
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
-               *retval = *EG(uninitialized_zval_ptr);
+               ZVAL_NULL(retval);
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -13545,7 +14465,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_VAR(incdec_t
                        have_get_ptr = 1;
                        SEPARATE_ZVAL_IF_NOT_REF(zptr);
 
-                       *retval = **zptr;
+                       ZVAL_COPY_VALUE(retval, *zptr);
                        zendi_zval_copy_ctor(*retval);
 
                        incdec_op(*zptr);
@@ -13558,7 +14478,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_VAR(incdec_t
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
                        zval *z_copy;
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -13568,12 +14488,11 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_VAR(incdec_t
                                }
                                z = value;
                        }
-                       *retval = *z;
+                       ZVAL_COPY_VALUE(retval, z);
                        zendi_zval_copy_ctor(*retval);
                        ALLOC_ZVAL(z_copy);
-                       *z_copy = *z;
+                       INIT_PZVAL_COPY(z_copy, z);
                        zendi_zval_copy_ctor(*z_copy);
-                       INIT_PZVAL(z_copy);
                        incdec_op(z_copy);
                        Z_ADDREF_P(z);
                        Z_OBJ_HT_P(object)->write_property(object, property, z_copy, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
@@ -13581,7 +14500,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_VAR(incdec_t
                        zval_ptr_dtor(&z);
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-                       *retval = *EG(uninitialized_zval_ptr);
+                       ZVAL_NULL(retval);
                }
        }
 
@@ -13591,6 +14510,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_VAR(incdec_t
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -13606,195 +14526,194 @@ static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HAN
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *dim = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
        zval **container;
 
+       SAVE_OPLINE();
+
        if ((opline->extended_value & ZEND_FETCH_ADD_LOCK) &&
            IS_VAR != IS_CV &&
            EX_T(opline->op1.var).var.ptr_ptr) {
                PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
        }
-       container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       if (IS_VAR == IS_VAR && !container) {
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address_read(!RETURN_VALUE_USED(opline)?NULL:&EX_T(opline->result.var), container, dim, IS_VAR, BP_VAR_R TSRMLS_CC);
+       zend_fetch_dimension_address_read(!RETURN_VALUE_USED(opline)?NULL:&EX_T(opline->result.var), container, _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_VAR, BP_VAR_R TSRMLS_CC);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *dim = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **container;
 
-       if (IS_VAR == IS_VAR && !container) {
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_VAR, BP_VAR_W TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_VAR, BP_VAR_W TSRMLS_CC);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
        /* We are going to assign the result by reference */
-       if (opline->extended_value && EX_T(opline->result.var).var.ptr_ptr) {
-               Z_DELREF_PP(EX_T(opline->result.var).var.ptr_ptr);
-               SEPARATE_ZVAL_TO_MAKE_IS_REF(EX_T(opline->result.var).var.ptr_ptr);
-               Z_ADDREF_PP(EX_T(opline->result.var).var.ptr_ptr);
+       if (UNEXPECTED(opline->extended_value != 0)) {
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+
+               if (retval_ptr) {
+                       Z_DELREF_PP(retval_ptr);
+                       SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
+                       Z_ADDREF_PP(retval_ptr);
+               }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *dim = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **container;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (IS_VAR == IS_VAR && !container) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_VAR, BP_VAR_RW TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_VAR, BP_VAR_RW TSRMLS_CC);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *dim = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **container;
 
-       if (IS_VAR == IS_VAR && !container) {
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, dim, IS_VAR, BP_VAR_IS TSRMLS_CC);
+       zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_VAR, BP_VAR_IS TSRMLS_CC);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *dim = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
        zval **container;
 
+       SAVE_OPLINE();
+
        if (ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))) {
-               container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-               if (IS_VAR == IS_VAR && !container) {
+               container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_VAR, BP_VAR_W TSRMLS_CC);
-               if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-                   READY_TO_DESTROY(free_op1.var)) {
-                       AI_USE_PTR(EX_T(opline->result.var).var);
-                       if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                           Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                               SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-                       }
+               zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_VAR, BP_VAR_W TSRMLS_CC);
+               if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+                       EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
                }
        } else {
                if (IS_VAR == IS_UNUSED) {
                        zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
                }
-               container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-               if (IS_VAR == IS_VAR && !container) {
+               container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, dim, IS_VAR, BP_VAR_R TSRMLS_CC);
+               zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_VAR, BP_VAR_R TSRMLS_CC);
        }
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_UNSET_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       zval *dim = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **container;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       /* Not needed in DIM_UNSET
-       if (opline->extended_value & ZEND_FETCH_ADD_LOCK) {
-               PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
-       }
-       */
        if (IS_VAR == IS_CV) {
                if (container != &EG(uninitialized_zval_ptr)) {
                        SEPARATE_ZVAL_IF_NOT_REF(container);
                }
        }
-       if (IS_VAR == IS_VAR && !container) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_VAR, BP_VAR_UNSET TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_VAR, BP_VAR_UNSET TSRMLS_CC);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
-       if (EX_T(opline->result.var).var.ptr_ptr == NULL) {
+       if (UNEXPECTED(EX_T(opline->result.var).var.ptr_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
        } else {
                zend_free_op free_res;
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
 
-               PZVAL_UNLOCK(*EX_T(opline->result.var).var.ptr_ptr, &free_res);
-               if (EX_T(opline->result.var).var.ptr_ptr != &EG(uninitialized_zval_ptr)) {
-                       SEPARATE_ZVAL_IF_NOT_REF(EX_T(opline->result.var).var.ptr_ptr);
+               PZVAL_UNLOCK(*retval_ptr, &free_res);
+               if (retval_ptr != &EG(uninitialized_zval_ptr)) {
+                       SEPARATE_ZVAL_IF_NOT_REF(retval_ptr);
                }
-               PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
+               PZVAL_LOCK(*retval_ptr);
                FREE_OP_VAR_PTR(free_res);
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
        }
-       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_VAR_VAR(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_VAR_VAR(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *container = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *container;
        zend_free_op free_op2;
-       zval *offset  = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval *offset;
 
-       if (Z_TYPE_P(container) != IS_OBJECT || !Z_OBJ_HT_P(container)->read_property) {
-               if (type != BP_VAR_IS) {
-                       zend_error(E_NOTICE, "Trying to get property of non-object");
-               }
+       SAVE_OPLINE();
+       container = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       offset  = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               zend_error(E_NOTICE, "Trying to get property of non-object");
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        } else {
@@ -13805,7 +14724,7 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_VAR_VAR(in
                }
 
                /* here we are sure we are dealing with an object */
-               retval = Z_OBJ_HT_P(container)->read_property(container, offset, type, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
                if (!RETURN_VALUE_USED(opline)) {
                        if (Z_REFCOUNT_P(retval) == 0) {
@@ -13814,8 +14733,8 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_VAR_VAR(in
                                FREE_ZVAL(retval);
                        }
                } else {
-                       AI_SET_PTR(EX_T(opline->result.var).var, retval);
                        PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                }
 
                if (0) {
@@ -13826,21 +14745,25 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_VAR_VAR(in
        }
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_property_address_read_helper_SPEC_VAR_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_fetch_property_address_read_helper_SPEC_VAR_VAR(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *property = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval *property;
        zval **container;
 
+       SAVE_OPLINE();
+       property = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
        if (IS_VAR == IS_VAR && (opline->extended_value & ZEND_FETCH_ADD_LOCK)) {
                PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
                EX_T(opline->op1.var).var.ptr = *EX_T(opline->op1.var).var.ptr_ptr;
@@ -13849,47 +14772,50 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HAND
        if (0) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       if (IS_VAR == IS_VAR && !container) {
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
+
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
        if (0) {
                zval_ptr_dtor(&property);
        } else {
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        }
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
        /* We are going to assign the result by reference */
        if (opline->extended_value & ZEND_FETCH_MAKE_REF) {
-               Z_DELREF_PP(EX_T(opline->result.var).var.ptr_ptr);
-               SEPARATE_ZVAL_TO_MAKE_IS_REF(EX_T(opline->result.var).var.ptr_ptr);
-               Z_ADDREF_PP(EX_T(opline->result.var).var.ptr_ptr);
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+
+               Z_DELREF_PP(retval_ptr);
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
+               Z_ADDREF_PP(retval_ptr);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *property = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *property;
+       zval **container;
+
+       SAVE_OPLINE();
+       property = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
        if (0) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       if (IS_VAR == IS_VAR && !container) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_RW TSRMLS_CC);
@@ -13898,37 +14824,84 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HAN
        } else {
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        }
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_property_address_read_helper_SPEC_VAR_VAR(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *container;
+       zend_free_op free_op2;
+       zval *offset;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       offset  = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               if (RETURN_VALUE_USED(opline)) {
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+               }
+               if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       } else {
+               zval *retval;
+
+               if (0) {
+                       MAKE_REAL_ZVAL_PTR(offset);
+               }
+
+               /* here we are sure we are dealing with an object */
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+
+               if (!RETURN_VALUE_USED(opline)) {
+                       if (Z_REFCOUNT_P(retval) == 0) {
+                               GC_REMOVE_ZVAL_FROM_BUFFER(retval);
+                               zval_dtor(retval);
+                               FREE_ZVAL(retval);
+                       }
+               } else {
+                       PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
+               }
+
+               if (0) {
+                       zval_ptr_dtor(&offset);
+               } else {
+                       if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+               }
+       }
+
+       if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        if (ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))) {
                /* Behave like FETCH_OBJ_W */
                zend_free_op free_op1, free_op2;
-               zval *property = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-               zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+               zval *property;
+               zval **container;
+
+               SAVE_OPLINE();
+               property = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+               container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
                if (0) {
                        MAKE_REAL_ZVAL_PTR(property);
                }
-               if (IS_VAR == IS_VAR && !container) {
+               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
                }
                zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
@@ -13937,27 +14910,27 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_VAR_HANDLER(ZEND_OPCO
                } else {
                        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
                }
-               if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-                   READY_TO_DESTROY(free_op1.var)) {
-                       AI_USE_PTR(EX_T(opline->result.var).var);
-                       if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                           Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                               SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-                       }
+               if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+                       EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
                }
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
-               return zend_fetch_property_address_read_helper_SPEC_VAR_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_fetch_property_address_read_helper_SPEC_VAR_VAR(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2, free_res;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       zval *property = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **container;
+       zval *property;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       property = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
        if (IS_VAR == IS_CV) {
                if (container != &EG(uninitialized_zval_ptr)) {
@@ -13967,7 +14940,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_
        if (0) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       if (IS_VAR == IS_VAR && !container) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_UNSET TSRMLS_CC);
@@ -13976,13 +14949,8 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_
        } else {
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        }
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
@@ -13992,24 +14960,28 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_
        }
        PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
        FREE_OP_VAR_PTR(free_res);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       zval *property_name = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **object_ptr;
+       zval *property_name;
+
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       property_name = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
        if (0) {
                MAKE_REAL_ZVAL_PTR(property_name);
        }
-       if (IS_VAR == IS_VAR && !object_ptr) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, op_data->op1_type, &op_data->op1, EX(Ts), ZEND_ASSIGN_OBJ, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), ZEND_ASSIGN_OBJ, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
        if (0) {
                zval_ptr_dtor(&property_name);
        } else {
@@ -14017,28 +14989,31 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDL
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **object_ptr;
 
-       if (IS_VAR == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
        if (Z_TYPE_PP(object_ptr) == IS_OBJECT) {
                zend_free_op free_op2;
-               zval *property_name = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+               zval *property_name = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
                if (0) {
                        MAKE_REAL_ZVAL_PTR(property_name);
                }
-               zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, op_data->op1_type, &op_data->op1, EX(Ts), ZEND_ASSIGN_DIM, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+               zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), ZEND_ASSIGN_DIM, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
                if (0) {
                        zval_ptr_dtor(&property_name);
                } else {
@@ -14047,31 +15022,45 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDL
        } else {
                zend_free_op free_op2, free_op_data1, free_op_data2;
                zval *value;
-               zval *dim = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+               zval *dim = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
                zval **variable_ptr_ptr;
 
-               zend_fetch_dimension_address(&EX_T(op_data->op2.var), object_ptr, dim, IS_VAR, BP_VAR_W TSRMLS_CC);
+               zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), object_ptr, dim, IS_VAR, BP_VAR_W TSRMLS_CC);
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
 
-               value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-               variable_ptr_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-               if (!variable_ptr_ptr) {
-                       if (zend_assign_to_string_offset(&EX_T(op_data->op2.var), value, op_data->op1_type TSRMLS_CC)) {
+               value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+               variable_ptr_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
+               if (UNEXPECTED(variable_ptr_ptr == NULL)) {
+                       if (zend_assign_to_string_offset(&EX_T((opline+1)->op2.var), value, (opline+1)->op1_type TSRMLS_CC)) {
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-                                       ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                                       INIT_PZVAL(EX_T(opline->result.var).var.ptr);
-                                       ZVAL_STRINGL(EX_T(opline->result.var).var.ptr, Z_STRVAL_P(EX_T(op_data->op2.var).str_offset.str)+EX_T(op_data->op2.var).str_offset.offset, 1, 1);
+                                       zval *retval;
+
+                                       ALLOC_ZVAL(retval);
+                                       ZVAL_STRINGL(retval, Z_STRVAL_P(EX_T((opline+1)->op2.var).str_offset.str)+EX_T((opline+1)->op2.var).str_offset.offset, 1, 1);
+                                       INIT_PZVAL(retval);
+                                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                                }
                        } else if (RETURN_VALUE_USED(opline)) {
-                               AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                               PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+                       }
+               } else if (UNEXPECTED(*variable_ptr_ptr == &EG(error_zval))) {
+                       if (IS_TMP_FREE(free_op_data1)) {
+                               zval_dtor(value);
+                       }
+                       if (RETURN_VALUE_USED(opline)) {
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                        }
                } else {
-                       value = zend_assign_to_variable(variable_ptr_ptr, value, IS_TMP_FREE(free_op_data1) TSRMLS_CC);
+                       if (IS_TMP_FREE(free_op_data1)) {
+                               value = zend_assign_tmp_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+                       } else {
+                               value = zend_assign_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+                       }
                        if (RETURN_VALUE_USED(opline)) {
-                               AI_SET_PTR(EX_T(opline->result.var).var, value);
                                PZVAL_LOCK(value);
+                               AI_SET_PTR(&EX_T(opline->result.var), value);
                        }
                }
                FREE_OP_VAR_PTR(free_op_data2);
@@ -14079,34 +15068,53 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDL
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        /* assign_dim has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *value = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **variable_ptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *value;
+       zval **variable_ptr_ptr;
+
+       SAVE_OPLINE();
+       value = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       variable_ptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (IS_VAR == IS_VAR && !variable_ptr_ptr) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(variable_ptr_ptr == NULL)) {
                if (zend_assign_to_string_offset(&EX_T(opline->op1.var), value, IS_VAR TSRMLS_CC)) {
                        if (RETURN_VALUE_USED(opline)) {
-                               EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-                               ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                               INIT_PZVAL(EX_T(opline->result.var).var.ptr);
-                               ZVAL_STRINGL(EX_T(opline->result.var).var.ptr, Z_STRVAL_P(EX_T(opline->op1.var).str_offset.str)+EX_T(opline->op1.var).str_offset.offset, 1, 1);
+                               zval *retval;
+
+                               ALLOC_ZVAL(retval);
+                               ZVAL_STRINGL(retval, Z_STRVAL_P(EX_T(opline->op1.var).str_offset.str)+EX_T(opline->op1.var).str_offset.offset, 1, 1);
+                               INIT_PZVAL(retval);
+                               AI_SET_PTR(&EX_T(opline->result.var), retval);
                        }
                } else if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+               }
+       } else if (IS_VAR == IS_VAR && UNEXPECTED(*variable_ptr_ptr == &EG(error_zval))) {
+               if (0) {
+                       zval_dtor(value);
+               }
+               if (RETURN_VALUE_USED(opline)) {
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
        } else {
-               value = zend_assign_to_variable(variable_ptr_ptr, value, 0 TSRMLS_CC);
+               if (0) {
+                       value = zend_assign_tmp_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+               } else {
+                       value = zend_assign_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+               }
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, value);
                        PZVAL_LOCK(value);
+                       AI_SET_PTR(&EX_T(opline->result.var), value);
                }
        }
 
@@ -14115,15 +15123,19 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_A
        /* zend_assign_to_variable() always takes care of op2, never free it! */
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_REF_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval **variable_ptr_ptr;
-       zval **value_ptr_ptr = _get_zval_ptr_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **value_ptr_ptr;
+
+       SAVE_OPLINE();
+       value_ptr_ptr = _get_zval_ptr_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
        if (IS_VAR == IS_VAR &&
            value_ptr_ptr &&
@@ -14136,19 +15148,19 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_REF_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDL
                zend_error(E_STRICT, "Only variables should be assigned by reference");
                if (UNEXPECTED(EG(exception) != NULL)) {
                        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
-                       ZEND_VM_NEXT_OPCODE();
+                       HANDLE_EXCEPTION();
                }
                return ZEND_ASSIGN_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (IS_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
                PZVAL_LOCK(*value_ptr_ptr);
        }
-       if (IS_VAR == IS_VAR && EX_T(opline->op1.var).var.ptr_ptr == &EX_T(opline->op1.var).var.ptr) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(EX_T(opline->op1.var).var.ptr_ptr == &EX_T(opline->op1.var).var.ptr)) {
                zend_error_noreturn(E_ERROR, "Cannot assign by reference to overloaded object");
        }
 
-       variable_ptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       if ((IS_VAR == IS_VAR && !value_ptr_ptr) ||
-           (IS_VAR == IS_VAR && !variable_ptr_ptr)) {
+       variable_ptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       if ((IS_VAR == IS_VAR && UNEXPECTED(value_ptr_ptr == NULL)) ||
+           (IS_VAR == IS_VAR && UNEXPECTED(variable_ptr_ptr == NULL))) {
                zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
        }
        zend_assign_to_variable_reference(variable_ptr_ptr, value_ptr_ptr TSRMLS_CC);
@@ -14158,45 +15170,49 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_REF_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDL
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *variable_ptr_ptr);
                PZVAL_LOCK(*variable_ptr_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *variable_ptr_ptr);
        }
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        char *function_name_strval;
        int function_name_strlen;
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
-       function_name = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       function_name = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
-       if (Z_TYPE_P(function_name)!=IS_STRING) {
+       if (IS_VAR != IS_CONST &&
+           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                zend_error_noreturn(E_ERROR, "Method name must be a string");
        }
 
        function_name_strval = Z_STRVAL_P(function_name);
        function_name_strlen = Z_STRLEN_P(function_name);
 
-       EX(object) = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       EX(object) = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (EX(object) && Z_TYPE_P(EX(object)) == IS_OBJECT) {
-               if (Z_OBJ_HT_P(EX(object))->get_method == NULL) {
+       if (EXPECTED(EX(object) != NULL) &&
+           EXPECTED(Z_TYPE_P(EX(object)) == IS_OBJECT)) {
+               if (UNEXPECTED(Z_OBJ_HT_P(EX(object))->get_method == NULL)) {
                        zend_error_noreturn(E_ERROR, "Object does not support method calls");
                }
 
                /* First, locate the function. */
                EX(fbc) = Z_OBJ_HT_P(EX(object))->get_method(&EX(object), function_name_strval, function_name_strlen, ((IS_VAR == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
-               if (!EX(fbc)) {
+               if (UNEXPECTED(EX(fbc) == NULL)) {
                        zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", Z_OBJ_CLASS_NAME_P(EX(object)), function_name_strval);
                }
 
@@ -14222,21 +15238,23 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        zend_class_entry *ce;
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
        if (IS_VAR == IS_CONST) {
                /* no function found. try a static method in class */
                ce = zend_fetch_class_by_name(Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), opline->op1.literal + 1, opline->extended_value TSRMLS_CC);
-               if (!ce) {
+               if (UNEXPECTED(ce == NULL)) {
                        zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
                }
                EX(called_scope) = ce;
@@ -14258,9 +15276,9 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_VAR_HANDLER(ZEND
                        function_name_strval = Z_STRVAL_P(opline->op2.zv);
                        function_name_strlen = Z_STRLEN_P(opline->op2.zv);
                } else {
-                       function_name = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+                       function_name = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
-                       if (Z_TYPE_P(function_name) != IS_STRING) {
+                       if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                                zend_error_noreturn(E_ERROR, "Function name must be a string");
                        } else {
                                function_name_strval = Z_STRVAL_P(function_name);
@@ -14274,7 +15292,7 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_VAR_HANDLER(ZEND
                        } else {
                                EX(fbc) = zend_std_get_static_method(ce, function_name_strval, function_name_strlen, ((IS_VAR == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
                        }
-                       if (!EX(fbc)) {
+                       if (UNEXPECTED(EX(fbc) == NULL)) {
                                zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name, function_name_strval);
                        }
                }
@@ -14283,11 +15301,11 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_VAR_HANDLER(ZEND
                        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
                }
        } else {
-               if(!ce->constructor) {
+               if (UNEXPECTED(ce->constructor == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot call constructor");
                }
                if (EG(This) && Z_OBJCE_P(EG(This)) != ce->constructor->common.scope && (ce->constructor->common.fn_flags & ZEND_ACC_PRIVATE)) {
-                       zend_error(E_COMPILE_ERROR, "Cannot call private %s::__construct()", ce->name);
+                       zend_error_noreturn(E_ERROR, "Cannot call private %s::__construct()", ce->name);
                }
                EX(fbc) = ce->constructor;
        }
@@ -14319,15 +15337,17 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_VAR_HANDLER(ZEND
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CASE_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        int switch_expr_is_overloaded=0;
        zend_free_op free_op1, free_op2;
 
+       SAVE_OPLINE();
        if (IS_VAR==IS_VAR) {
                if (EX_T(opline->op1.var).var.ptr_ptr) {
                        PZVAL_LOCK(EX_T(opline->op1.var).var.ptr);
@@ -14337,8 +15357,8 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
                }
        }
        is_equal_function(&EX_T(opline->result.var).tmp_var,
-                                _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-                                _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+                                _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+                                _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        if (switch_expr_is_overloaded) {
@@ -14351,47 +15371,32 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARG
                EX_T(opline->op1.var).var.ptr_ptr = NULL;
                EX_T(opline->op1.var).var.ptr = NULL;
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_free_op free_op1, free_op2;
-       zval *array_ptr = &EX_T(opline->result.var).tmp_var;
+       USE_OPLINE
+       zend_free_op free_op1;
        zval *expr_ptr;
-       zval *offset=_get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       ulong hval;
-       long index;
 
-#if 0 || IS_VAR == IS_VAR || IS_VAR == IS_CV
-       zval **expr_ptr_ptr = NULL;
+       SAVE_OPLINE();
+       if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && opline->extended_value) {
+               zval **expr_ptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (opline->extended_value) {
-               expr_ptr_ptr=_get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
                expr_ptr = *expr_ptr_ptr;
+               Z_ADDREF_P(expr_ptr);
        } else {
-               expr_ptr=_get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       }
-#else
-       expr_ptr=_get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-#endif
-
-       if (0) { /* temporary variable */
-               zval *new_expr;
+               expr_ptr=_get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+               if (0) { /* temporary variable */
+                       zval *new_expr;
 
-               ALLOC_ZVAL(new_expr);
-               INIT_PZVAL_COPY(new_expr, expr_ptr);
-               expr_ptr = new_expr;
-       } else {
-#if 0 || IS_VAR == IS_VAR || IS_VAR == IS_CV
-               if (opline->extended_value) {
-                       SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
-                       expr_ptr = *expr_ptr_ptr;
-                       Z_ADDREF_P(expr_ptr);
-               } else
-#endif
-               if (IS_VAR == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
+                       ALLOC_ZVAL(new_expr);
+                       INIT_PZVAL_COPY(new_expr, expr_ptr);
+                       expr_ptr = new_expr;
+               } else if (IS_VAR == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
                        zval *new_expr;
 
                        ALLOC_ZVAL(new_expr);
@@ -14402,7 +15407,13 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_VAR_HANDLER(ZEND_OPCOD
                        Z_ADDREF_P(expr_ptr);
                }
        }
-       if (offset) {
+
+       if (IS_VAR != IS_UNUSED) {
+               zend_free_op free_op2;
+               zval *offset = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+               ulong hval;
+               long index;
+
                switch (Z_TYPE_P(offset)) {
                        case IS_DOUBLE:
                                index = zend_dval_to_lval(Z_DVAL_P(offset));
@@ -14411,7 +15422,7 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_VAR_HANDLER(ZEND_OPCOD
                        case IS_BOOL:
                                index = Z_LVAL_P(offset);
 num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(array_ptr), index, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_index_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), index, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_STRING:
                                if (IS_VAR == IS_CONST) {
@@ -14424,10 +15435,10 @@ num_index:
                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                        }
                                }
-                               zend_hash_quick_update(Z_ARRVAL_P(array_ptr), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_quick_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_NULL:
-                               zend_hash_update(Z_ARRVAL_P(array_ptr), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
                                break;
                        default:
                                zend_error(E_WARNING, "Illegal offset type");
@@ -14437,19 +15448,20 @@ num_index:
                }
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(array_ptr), &expr_ptr, sizeof(zval *), NULL);
+               zend_hash_next_index_insert(Z_ARRVAL(EX_T(opline->result.var).tmp_var), &expr_ptr, sizeof(zval *), NULL);
        }
-       if (opline->extended_value) {
+       if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && opline->extended_value) {
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        } else {
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (IS_VAR == IS_UNUSED) {
@@ -14463,13 +15475,17 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDL
 
 static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       zval *offset = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **container;
+       zval *offset;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       offset = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
        if (IS_VAR != IS_VAR || container) {
                if (IS_VAR == IS_CV && container != &EG(uninitialized_zval_ptr)) {
                        SEPARATE_ZVAL_IF_NOT_REF(container);
@@ -14503,24 +15519,10 @@ num_index_dim:
                                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                                        }
                                                }
-                                               if (zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval) == SUCCESS &&
-                                           ht == &EG(symbol_table)) {
-                                                       zend_execute_data *ex;
-
-                                                       for (ex = execute_data; ex; ex = ex->prev_execute_data) {
-                                                               if (ex->op_array && ex->symbol_table == ht) {
-                                                                       int i;
-
-                                                                       for (i = 0; i < ex->op_array->last_var; i++) {
-                                                                               if (ex->op_array->vars[i].hash_value == hval &&
-                                                                                   ex->op_array->vars[i].name_len == offset->value.str.len &&
-                                                                                   !memcmp(ex->op_array->vars[i].name, offset->value.str.val, offset->value.str.len)) {
-                                                                                       ex->CVs[i] = NULL;
-                                                                                       break;
-                                                                               }
-                                                                       }
-                                                               }
-                                                       }
+                                               if (ht == &EG(symbol_table)) {
+                                                       zend_delete_global_variable_ex(offset->value.str.val, offset->value.str.len, hval TSRMLS_CC);
+                                               } else {
+                                                       zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval);
                                                }
                                                if (IS_VAR == IS_CV || IS_VAR == IS_VAR) {
                                                        zval_ptr_dtor(&offset);
@@ -14537,7 +15539,7 @@ num_index_dim:
                                break;
                        }
                        case IS_OBJECT:
-                               if (!Z_OBJ_HT_P(*container)->unset_dimension) {
+                               if (UNEXPECTED(Z_OBJ_HT_P(*container)->unset_dimension == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use object as array");
                                }
                                if (0) {
@@ -14562,15 +15564,20 @@ num_index_dim:
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       zval *offset = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **container;
+       zval *offset;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       offset = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
        if (IS_VAR != IS_VAR || container) {
                if (IS_VAR == IS_CV && container != &EG(uninitialized_zval_ptr)) {
@@ -14598,22 +15605,26 @@ static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_OPCODE_HANDLE
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_isset_isempty_dim_prop_obj_handler_SPEC_VAR_VAR(int prop_dim, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **container;
        zval **value = NULL;
        int result = 0;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
        if (IS_VAR != IS_VAR || container) {
                zend_free_op free_op2;
-               zval *offset = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+               zval *offset = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
                if (Z_TYPE_PP(container) == IS_ARRAY && !prop_dim) {
                        HashTable *ht;
@@ -14704,7 +15715,7 @@ num_index_prop:
                        zval tmp;
 
                        if (Z_TYPE_P(offset) != IS_LONG) {
-                               tmp = *offset;
+                               ZVAL_COPY_VALUE(&tmp, offset);
                                zval_copy_ctor(&tmp);
                                convert_to_long(&tmp);
                                offset = &tmp;
@@ -14727,15 +15738,15 @@ num_index_prop:
        }
 
        Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
-
        if (opline->extended_value & ZEND_ISSET) {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = result;
-       } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+       } else {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = !result;
        }
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -14751,33 +15762,31 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_VAR_HANDLER(ZEND_
 
 static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_UNUSED(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op1, free_op_data1;
-       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
        zval *object;
        zval *property = NULL;
-       zval *value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
+       zval *value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
        znode_op *result = &opline->result;
        int have_get_ptr = 0;
 
-       if (IS_VAR == IS_VAR && !object_ptr) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
 
-       EX_T(result->var).var.ptr_ptr = NULL;
        make_real_object(object_ptr TSRMLS_CC);
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to assign property of non-object");
 
                FREE_OP(free_op_data1);
 
                if (RETURN_VALUE_USED(opline)) {
-                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                       EX_T(result->var).var.ptr_ptr = NULL;
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                }
        } else {
                /* here we are sure we are dealing with an object */
@@ -14795,9 +15804,9 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_UNUSED(int (*
                                have_get_ptr = 1;
                                binary_op(*zptr, *zptr, value TSRMLS_CC);
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = *zptr;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(*zptr);
+                                       EX_T(opline->result.var).var.ptr = *zptr;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -14834,17 +15843,17 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_UNUSED(int (*
                                        Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
                                }
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = z;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(z);
+                                       EX_T(opline->result.var).var.ptr = z;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                                zval_ptr_dtor(&z);
                        } else {
                                zend_error(E_WARNING, "Attempt to assign property of non-object");
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                                       EX_T(result->var).var.ptr_ptr = NULL;
-                                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                                       PZVAL_LOCK(&EG(uninitialized_zval));
+                                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -14859,66 +15868,71 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_UNUSED(int (*
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_UNUSED(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op_data2, free_op_data1;
        zval **var_ptr;
        zval *value;
 
+       SAVE_OPLINE();
        switch (opline->extended_value) {
                case ZEND_ASSIGN_OBJ:
                        return zend_binary_assign_op_obj_helper_SPEC_VAR_UNUSED(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                        break;
                case ZEND_ASSIGN_DIM: {
-                               zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+                               zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-                               if (IS_VAR == IS_VAR && !container) {
+                               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-                               } else if (Z_TYPE_PP(container) == IS_OBJECT) {
+                               } else if (UNEXPECTED(Z_TYPE_PP(container) == IS_OBJECT)) {
                                        if (IS_VAR == IS_VAR && !(free_op1.var != NULL)) {
                                                Z_ADDREF_PP(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
                                        }
                                        return zend_binary_assign_op_obj_helper_SPEC_VAR_UNUSED(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                                } else {
-                                       zend_op *op_data = opline+1;
                                        zval *dim = NULL;
 
-                                       zend_fetch_dimension_address(&EX_T(op_data->op2.var), container, dim, IS_UNUSED, BP_VAR_RW TSRMLS_CC);
-                                       value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-                                       var_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-                                       ZEND_VM_INC_OPCODE();
+                                       zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), container, dim, IS_UNUSED, BP_VAR_RW TSRMLS_CC);
+                                       value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+                                       var_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
                                }
                        }
                        break;
                default:
                        value = NULL;
-                       var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+                       var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
                        /* do nothing */
                        break;
        }
 
-       if (!var_ptr) {
+       if (UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
        }
 
-       if (*var_ptr == EG(error_zval_ptr)) {
+       if (UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
 
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
+               if (opline->extended_value == ZEND_ASSIGN_DIM) {
+                       ZEND_VM_INC_OPCODE();
+               }
                ZEND_VM_NEXT_OPCODE();
        }
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *objval = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -14931,15 +15945,20 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_UNUSED(int (*bina
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *var_ptr);
                PZVAL_LOCK(*var_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *var_ptr);
        }
 
        if (opline->extended_value == ZEND_ASSIGN_DIM) {
                FREE_OP(free_op_data1);
                FREE_OP_VAR_PTR(free_op_data2);
+               if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
+               ZEND_VM_INC_OPCODE();
+       } else {
+               if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
        }
-       if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -15000,104 +16019,103 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *dim = NULL;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **container;
 
-       if (IS_VAR == IS_VAR && !container) {
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_UNUSED, BP_VAR_W TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, NULL, IS_UNUSED, BP_VAR_W TSRMLS_CC);
 
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
        /* We are going to assign the result by reference */
-       if (opline->extended_value && EX_T(opline->result.var).var.ptr_ptr) {
-               Z_DELREF_PP(EX_T(opline->result.var).var.ptr_ptr);
-               SEPARATE_ZVAL_TO_MAKE_IS_REF(EX_T(opline->result.var).var.ptr_ptr);
-               Z_ADDREF_PP(EX_T(opline->result.var).var.ptr_ptr);
+       if (UNEXPECTED(opline->extended_value != 0)) {
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+
+               if (retval_ptr) {
+                       Z_DELREF_PP(retval_ptr);
+                       SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
+                       Z_ADDREF_PP(retval_ptr);
+               }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *dim = NULL;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **container;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (IS_VAR == IS_VAR && !container) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_UNUSED, BP_VAR_RW TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, NULL, IS_UNUSED, BP_VAR_RW TSRMLS_CC);
 
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *dim = NULL;
        zval **container;
 
+       SAVE_OPLINE();
+
        if (ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))) {
-               container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-               if (IS_VAR == IS_VAR && !container) {
+               container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_UNUSED, BP_VAR_W TSRMLS_CC);
-               if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-                   READY_TO_DESTROY(free_op1.var)) {
-                       AI_USE_PTR(EX_T(opline->result.var).var);
-                       if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                           Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                               SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-                       }
+               zend_fetch_dimension_address(&EX_T(opline->result.var), container, NULL, IS_UNUSED, BP_VAR_W TSRMLS_CC);
+               if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+                       EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
                }
        } else {
                if (IS_UNUSED == IS_UNUSED) {
                        zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
                }
-               container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-               if (IS_VAR == IS_VAR && !container) {
+               container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, dim, IS_UNUSED, BP_VAR_R TSRMLS_CC);
+               zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, NULL, IS_UNUSED, BP_VAR_R TSRMLS_CC);
        }
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **object_ptr;
+
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (IS_VAR == IS_VAR && !object_ptr) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
        if (Z_TYPE_PP(object_ptr) == IS_OBJECT) {
@@ -15107,7 +16125,7 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HA
                if (0) {
                        MAKE_REAL_ZVAL_PTR(property_name);
                }
-               zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, op_data->op1_type, &op_data->op1, EX(Ts), ZEND_ASSIGN_DIM, ((IS_UNUSED == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+               zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), ZEND_ASSIGN_DIM, ((IS_UNUSED == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
                if (0) {
                        zval_ptr_dtor(&property_name);
                } else {
@@ -15119,27 +16137,41 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HA
                zval *dim = NULL;
                zval **variable_ptr_ptr;
 
-               zend_fetch_dimension_address(&EX_T(op_data->op2.var), object_ptr, dim, IS_UNUSED, BP_VAR_W TSRMLS_CC);
+               zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), object_ptr, dim, IS_UNUSED, BP_VAR_W TSRMLS_CC);
 
-               value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-               variable_ptr_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-               if (!variable_ptr_ptr) {
-                       if (zend_assign_to_string_offset(&EX_T(op_data->op2.var), value, op_data->op1_type TSRMLS_CC)) {
+               value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+               variable_ptr_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
+               if (UNEXPECTED(variable_ptr_ptr == NULL)) {
+                       if (zend_assign_to_string_offset(&EX_T((opline+1)->op2.var), value, (opline+1)->op1_type TSRMLS_CC)) {
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-                                       ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                                       INIT_PZVAL(EX_T(opline->result.var).var.ptr);
-                                       ZVAL_STRINGL(EX_T(opline->result.var).var.ptr, Z_STRVAL_P(EX_T(op_data->op2.var).str_offset.str)+EX_T(op_data->op2.var).str_offset.offset, 1, 1);
+                                       zval *retval;
+
+                                       ALLOC_ZVAL(retval);
+                                       ZVAL_STRINGL(retval, Z_STRVAL_P(EX_T((opline+1)->op2.var).str_offset.str)+EX_T((opline+1)->op2.var).str_offset.offset, 1, 1);
+                                       INIT_PZVAL(retval);
+                                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                                }
                        } else if (RETURN_VALUE_USED(opline)) {
-                               AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                               PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+                       }
+               } else if (UNEXPECTED(*variable_ptr_ptr == &EG(error_zval))) {
+                       if (IS_TMP_FREE(free_op_data1)) {
+                               zval_dtor(value);
+                       }
+                       if (RETURN_VALUE_USED(opline)) {
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                        }
                } else {
-                       value = zend_assign_to_variable(variable_ptr_ptr, value, IS_TMP_FREE(free_op_data1) TSRMLS_CC);
+                       if (IS_TMP_FREE(free_op_data1)) {
+                               value = zend_assign_tmp_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+                       } else {
+                               value = zend_assign_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+                       }
                        if (RETURN_VALUE_USED(opline)) {
-                               AI_SET_PTR(EX_T(opline->result.var).var, value);
                                PZVAL_LOCK(value);
+                               AI_SET_PTR(&EX_T(opline->result.var), value);
                        }
                }
                FREE_OP_VAR_PTR(free_op_data2);
@@ -15147,22 +16179,24 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HA
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        /* assign_dim has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        zend_class_entry *ce;
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
        if (IS_VAR == IS_CONST) {
                /* no function found. try a static method in class */
                ce = zend_fetch_class_by_name(Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), opline->op1.literal + 1, opline->extended_value TSRMLS_CC);
-               if (!ce) {
+               if (UNEXPECTED(ce == NULL)) {
                        zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
                }
                EX(called_scope) = ce;
@@ -15186,7 +16220,7 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_UNUSED_HANDLER(Z
                } else {
                        function_name = NULL;
 
-                       if (Z_TYPE_P(function_name) != IS_STRING) {
+                       if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                                zend_error_noreturn(E_ERROR, "Function name must be a string");
                        } else {
                                function_name_strval = Z_STRVAL_P(function_name);
@@ -15200,7 +16234,7 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_UNUSED_HANDLER(Z
                        } else {
                                EX(fbc) = zend_std_get_static_method(ce, function_name_strval, function_name_strlen, ((IS_UNUSED == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
                        }
-                       if (!EX(fbc)) {
+                       if (UNEXPECTED(EX(fbc) == NULL)) {
                                zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name, function_name_strval);
                        }
                }
@@ -15209,11 +16243,11 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_UNUSED_HANDLER(Z
 
                }
        } else {
-               if(!ce->constructor) {
+               if (UNEXPECTED(ce->constructor == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot call constructor");
                }
                if (EG(This) && Z_OBJCE_P(EG(This)) != ce->constructor->common.scope && (ce->constructor->common.fn_flags & ZEND_ACC_PRIVATE)) {
-                       zend_error(E_COMPILE_ERROR, "Cannot call private %s::__construct()", ce->name);
+                       zend_error_noreturn(E_ERROR, "Cannot call private %s::__construct()", ce->name);
                }
                EX(fbc) = ce->constructor;
        }
@@ -15245,47 +16279,32 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_UNUSED_HANDLER(Z
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *array_ptr = &EX_T(opline->result.var).tmp_var;
        zval *expr_ptr;
-       zval *offset=NULL;
-       ulong hval;
-       long index;
 
-#if 0 || IS_VAR == IS_VAR || IS_VAR == IS_CV
-       zval **expr_ptr_ptr = NULL;
+       SAVE_OPLINE();
+       if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && opline->extended_value) {
+               zval **expr_ptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (opline->extended_value) {
-               expr_ptr_ptr=_get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
                expr_ptr = *expr_ptr_ptr;
+               Z_ADDREF_P(expr_ptr);
        } else {
-               expr_ptr=_get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       }
-#else
-       expr_ptr=_get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-#endif
-
-       if (0) { /* temporary variable */
-               zval *new_expr;
+               expr_ptr=_get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+               if (0) { /* temporary variable */
+                       zval *new_expr;
 
-               ALLOC_ZVAL(new_expr);
-               INIT_PZVAL_COPY(new_expr, expr_ptr);
-               expr_ptr = new_expr;
-       } else {
-#if 0 || IS_VAR == IS_VAR || IS_VAR == IS_CV
-               if (opline->extended_value) {
-                       SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
-                       expr_ptr = *expr_ptr_ptr;
-                       Z_ADDREF_P(expr_ptr);
-               } else
-#endif
-               if (IS_VAR == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
+                       ALLOC_ZVAL(new_expr);
+                       INIT_PZVAL_COPY(new_expr, expr_ptr);
+                       expr_ptr = new_expr;
+               } else if (IS_VAR == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
                        zval *new_expr;
 
                        ALLOC_ZVAL(new_expr);
@@ -15296,7 +16315,13 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_UNUSED_HANDLER(ZEND_OP
                        Z_ADDREF_P(expr_ptr);
                }
        }
-       if (offset) {
+
+       if (IS_UNUSED != IS_UNUSED) {
+
+               zval *offset = NULL;
+               ulong hval;
+               long index;
+
                switch (Z_TYPE_P(offset)) {
                        case IS_DOUBLE:
                                index = zend_dval_to_lval(Z_DVAL_P(offset));
@@ -15305,7 +16330,7 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_UNUSED_HANDLER(ZEND_OP
                        case IS_BOOL:
                                index = Z_LVAL_P(offset);
 num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(array_ptr), index, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_index_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), index, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_STRING:
                                if (IS_UNUSED == IS_CONST) {
@@ -15318,10 +16343,10 @@ num_index:
                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                        }
                                }
-                               zend_hash_quick_update(Z_ARRVAL_P(array_ptr), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_quick_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_NULL:
-                               zend_hash_update(Z_ARRVAL_P(array_ptr), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
                                break;
                        default:
                                zend_error(E_WARNING, "Illegal offset type");
@@ -15331,19 +16356,20 @@ num_index:
                }
 
        } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(array_ptr), &expr_ptr, sizeof(zval *), NULL);
+               zend_hash_next_index_insert(Z_ARRVAL(EX_T(opline->result.var).tmp_var), &expr_ptr, sizeof(zval *), NULL);
        }
-       if (opline->extended_value) {
+       if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && opline->extended_value) {
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        } else {
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (IS_VAR == IS_UNUSED) {
@@ -15357,277 +16383,311 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_VAR_UNUSED_HANDLER(ZEND_OPCODE_HA
 
 static int ZEND_FASTCALL  ZEND_ADD_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        add_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SUB_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        sub_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MUL_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        mul_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_DIV_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        div_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MOD_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        mod_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SL_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        shift_left_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SR_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        shift_right_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        concat_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        is_identical_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        is_identical_function(result,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        Z_LVAL_P(result) = !Z_LVAL_P(result);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) == 0));
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) != 0));
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) < 0));
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) <= 0));
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        bitwise_or_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        bitwise_and_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        bitwise_xor_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        boolean_xor_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_CV(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op1, free_op_data1;
-       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
        zval *object;
-       zval *property = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-       zval *value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
+       zval *property = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+       zval *value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
        znode_op *result = &opline->result;
        int have_get_ptr = 0;
 
-       if (IS_VAR == IS_VAR && !object_ptr) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
 
-       EX_T(result->var).var.ptr_ptr = NULL;
        make_real_object(object_ptr TSRMLS_CC);
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to assign property of non-object");
 
                FREE_OP(free_op_data1);
 
                if (RETURN_VALUE_USED(opline)) {
-                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                       EX_T(result->var).var.ptr_ptr = NULL;
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                }
        } else {
                /* here we are sure we are dealing with an object */
@@ -15645,9 +16705,9 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_CV(int (*bina
                                have_get_ptr = 1;
                                binary_op(*zptr, *zptr, value TSRMLS_CC);
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = *zptr;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(*zptr);
+                                       EX_T(opline->result.var).var.ptr = *zptr;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -15684,17 +16744,17 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_CV(int (*bina
                                        Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
                                }
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = z;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(z);
+                                       EX_T(opline->result.var).var.ptr = z;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                                zval_ptr_dtor(&z);
                        } else {
                                zend_error(E_WARNING, "Attempt to assign property of non-object");
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                                       EX_T(result->var).var.ptr_ptr = NULL;
-                                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                                       PZVAL_LOCK(&EG(uninitialized_zval));
+                                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -15709,66 +16769,71 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_VAR_CV(int (*bina
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_CV(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op_data2, free_op_data1;
        zval **var_ptr;
        zval *value;
 
+       SAVE_OPLINE();
        switch (opline->extended_value) {
                case ZEND_ASSIGN_OBJ:
                        return zend_binary_assign_op_obj_helper_SPEC_VAR_CV(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                        break;
                case ZEND_ASSIGN_DIM: {
-                               zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+                               zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-                               if (IS_VAR == IS_VAR && !container) {
+                               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-                               } else if (Z_TYPE_PP(container) == IS_OBJECT) {
+                               } else if (UNEXPECTED(Z_TYPE_PP(container) == IS_OBJECT)) {
                                        if (IS_VAR == IS_VAR && !(free_op1.var != NULL)) {
                                                Z_ADDREF_PP(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
                                        }
                                        return zend_binary_assign_op_obj_helper_SPEC_VAR_CV(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                                } else {
-                                       zend_op *op_data = opline+1;
-                                       zval *dim = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+                                       zval *dim = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
 
-                                       zend_fetch_dimension_address(&EX_T(op_data->op2.var), container, dim, IS_CV, BP_VAR_RW TSRMLS_CC);
-                                       value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-                                       var_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-                                       ZEND_VM_INC_OPCODE();
+                                       zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), container, dim, IS_CV, BP_VAR_RW TSRMLS_CC);
+                                       value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+                                       var_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
                                }
                        }
                        break;
                default:
-                       value = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-                       var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+                       value = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+                       var_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
                        /* do nothing */
                        break;
        }
 
-       if (!var_ptr) {
+       if (UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
        }
 
-       if (*var_ptr == EG(error_zval_ptr)) {
+       if (UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
 
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
+               if (opline->extended_value == ZEND_ASSIGN_DIM) {
+                       ZEND_VM_INC_OPCODE();
+               }
                ZEND_VM_NEXT_OPCODE();
        }
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *objval = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -15781,15 +16846,20 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_VAR_CV(int (*binary_o
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *var_ptr);
                PZVAL_LOCK(*var_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *var_ptr);
        }
 
        if (opline->extended_value == ZEND_ASSIGN_DIM) {
                FREE_OP(free_op_data1);
                FREE_OP_VAR_PTR(free_op_data2);
+               if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
+               ZEND_VM_INC_OPCODE();
+       } else {
+               if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
        }
-       if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -15850,29 +16920,35 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HAN
 
 static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_CV(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **object_ptr;
        zval *object;
-       zval *property = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-       zval **retval = &EX_T(opline->result.var).var.ptr;
+       zval *property;
+       zval **retval;
        int have_get_ptr = 0;
 
-       if (IS_VAR == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       property = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+       retval = &EX_T(opline->result.var).var.ptr;
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
 
                if (RETURN_VALUE_USED(opline)) {
-                       *retval = EG(uninitialized_zval_ptr);
-                       PZVAL_LOCK(*retval);
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       *retval = &EG(uninitialized_zval);
                }
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -15900,7 +16976,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_CV(incdec_t in
                if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -15920,8 +16996,8 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_CV(incdec_t in
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                        if (RETURN_VALUE_USED(opline)) {
-                               *retval = EG(uninitialized_zval_ptr);
-                               PZVAL_LOCK(*retval);
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               *retval = &EG(uninitialized_zval);
                        }
                }
        }
@@ -15932,6 +17008,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_VAR_CV(incdec_t in
 
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -15947,26 +17024,32 @@ static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDL
 
 static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_CV(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **object_ptr;
        zval *object;
-       zval *property = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-       zval *retval = &EX_T(opline->result.var).tmp_var;
+       zval *property;
+       zval *retval;
        int have_get_ptr = 0;
 
-       if (IS_VAR == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       property = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+       retval = &EX_T(opline->result.var).tmp_var;
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
 
-               *retval = *EG(uninitialized_zval_ptr);
+               ZVAL_NULL(retval);
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -15982,7 +17065,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_CV(incdec_t i
                        have_get_ptr = 1;
                        SEPARATE_ZVAL_IF_NOT_REF(zptr);
 
-                       *retval = **zptr;
+                       ZVAL_COPY_VALUE(retval, *zptr);
                        zendi_zval_copy_ctor(*retval);
 
                        incdec_op(*zptr);
@@ -15995,7 +17078,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_CV(incdec_t i
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
                        zval *z_copy;
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -16005,12 +17088,11 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_CV(incdec_t i
                                }
                                z = value;
                        }
-                       *retval = *z;
+                       ZVAL_COPY_VALUE(retval, z);
                        zendi_zval_copy_ctor(*retval);
                        ALLOC_ZVAL(z_copy);
-                       *z_copy = *z;
+                       INIT_PZVAL_COPY(z_copy, z);
                        zendi_zval_copy_ctor(*z_copy);
-                       INIT_PZVAL(z_copy);
                        incdec_op(z_copy);
                        Z_ADDREF_P(z);
                        Z_OBJ_HT_P(object)->write_property(object, property, z_copy, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
@@ -16018,7 +17100,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_CV(incdec_t i
                        zval_ptr_dtor(&z);
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-                       *retval = *EG(uninitialized_zval_ptr);
+                       ZVAL_NULL(retval);
                }
        }
 
@@ -16028,6 +17110,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_VAR_CV(incdec_t i
 
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -16043,195 +17126,194 @@ static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HAND
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *dim = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
        zval **container;
 
+       SAVE_OPLINE();
+
        if ((opline->extended_value & ZEND_FETCH_ADD_LOCK) &&
            IS_VAR != IS_CV &&
            EX_T(opline->op1.var).var.ptr_ptr) {
                PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
        }
-       container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       if (IS_VAR == IS_VAR && !container) {
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address_read(!RETURN_VALUE_USED(opline)?NULL:&EX_T(opline->result.var), container, dim, IS_CV, BP_VAR_R TSRMLS_CC);
+       zend_fetch_dimension_address_read(!RETURN_VALUE_USED(opline)?NULL:&EX_T(opline->result.var), container, _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC), IS_CV, BP_VAR_R TSRMLS_CC);
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *dim = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **container;
 
-       if (IS_VAR == IS_VAR && !container) {
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_CV, BP_VAR_W TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC), IS_CV, BP_VAR_W TSRMLS_CC);
 
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
        /* We are going to assign the result by reference */
-       if (opline->extended_value && EX_T(opline->result.var).var.ptr_ptr) {
-               Z_DELREF_PP(EX_T(opline->result.var).var.ptr_ptr);
-               SEPARATE_ZVAL_TO_MAKE_IS_REF(EX_T(opline->result.var).var.ptr_ptr);
-               Z_ADDREF_PP(EX_T(opline->result.var).var.ptr_ptr);
+       if (UNEXPECTED(opline->extended_value != 0)) {
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+
+               if (retval_ptr) {
+                       Z_DELREF_PP(retval_ptr);
+                       SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
+                       Z_ADDREF_PP(retval_ptr);
+               }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *dim = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **container;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (IS_VAR == IS_VAR && !container) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_CV, BP_VAR_RW TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC), IS_CV, BP_VAR_RW TSRMLS_CC);
 
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *dim = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **container;
 
-       if (IS_VAR == IS_VAR && !container) {
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, dim, IS_CV, BP_VAR_IS TSRMLS_CC);
+       zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC), IS_CV, BP_VAR_IS TSRMLS_CC);
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *dim = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
        zval **container;
 
+       SAVE_OPLINE();
+
        if (ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))) {
-               container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-               if (IS_VAR == IS_VAR && !container) {
+               container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_CV, BP_VAR_W TSRMLS_CC);
-               if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-                   READY_TO_DESTROY(free_op1.var)) {
-                       AI_USE_PTR(EX_T(opline->result.var).var);
-                       if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                           Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                               SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-                       }
+               zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC), IS_CV, BP_VAR_W TSRMLS_CC);
+               if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+                       EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
                }
        } else {
                if (IS_CV == IS_UNUSED) {
                        zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
                }
-               container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-               if (IS_VAR == IS_VAR && !container) {
+               container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, dim, IS_CV, BP_VAR_R TSRMLS_CC);
+               zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC), IS_CV, BP_VAR_R TSRMLS_CC);
        }
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_UNSET_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       zval *dim = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       zval **container;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       /* Not needed in DIM_UNSET
-       if (opline->extended_value & ZEND_FETCH_ADD_LOCK) {
-               PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
-       }
-       */
        if (IS_VAR == IS_CV) {
                if (container != &EG(uninitialized_zval_ptr)) {
                        SEPARATE_ZVAL_IF_NOT_REF(container);
                }
        }
-       if (IS_VAR == IS_VAR && !container) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_CV, BP_VAR_UNSET TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC), IS_CV, BP_VAR_UNSET TSRMLS_CC);
 
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
-       if (EX_T(opline->result.var).var.ptr_ptr == NULL) {
+       if (UNEXPECTED(EX_T(opline->result.var).var.ptr_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
        } else {
                zend_free_op free_res;
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
 
-               PZVAL_UNLOCK(*EX_T(opline->result.var).var.ptr_ptr, &free_res);
-               if (EX_T(opline->result.var).var.ptr_ptr != &EG(uninitialized_zval_ptr)) {
-                       SEPARATE_ZVAL_IF_NOT_REF(EX_T(opline->result.var).var.ptr_ptr);
+               PZVAL_UNLOCK(*retval_ptr, &free_res);
+               if (retval_ptr != &EG(uninitialized_zval_ptr)) {
+                       SEPARATE_ZVAL_IF_NOT_REF(retval_ptr);
                }
-               PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
+               PZVAL_LOCK(*retval_ptr);
                FREE_OP_VAR_PTR(free_res);
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
        }
-       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_VAR_CV(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_VAR_CV(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *container = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *container;
 
-       zval *offset  = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       zval *offset;
 
-       if (Z_TYPE_P(container) != IS_OBJECT || !Z_OBJ_HT_P(container)->read_property) {
-               if (type != BP_VAR_IS) {
-                       zend_error(E_NOTICE, "Trying to get property of non-object");
-               }
+       SAVE_OPLINE();
+       container = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       offset  = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               zend_error(E_NOTICE, "Trying to get property of non-object");
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
 
        } else {
@@ -16242,7 +17324,7 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_VAR_CV(int
                }
 
                /* here we are sure we are dealing with an object */
-               retval = Z_OBJ_HT_P(container)->read_property(container, offset, type, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
                if (!RETURN_VALUE_USED(opline)) {
                        if (Z_REFCOUNT_P(retval) == 0) {
@@ -16251,8 +17333,8 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_VAR_CV(int
                                FREE_ZVAL(retval);
                        }
                } else {
-                       AI_SET_PTR(EX_T(opline->result.var).var, retval);
                        PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                }
 
                if (0) {
@@ -16263,21 +17345,25 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_VAR_CV(int
        }
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_property_address_read_helper_SPEC_VAR_CV(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_fetch_property_address_read_helper_SPEC_VAR_CV(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *property = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       zval *property;
        zval **container;
 
+       SAVE_OPLINE();
+       property = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+
        if (IS_VAR == IS_VAR && (opline->extended_value & ZEND_FETCH_ADD_LOCK)) {
                PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
                EX_T(opline->op1.var).var.ptr = *EX_T(opline->op1.var).var.ptr_ptr;
@@ -16286,47 +17372,50 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDL
        if (0) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       if (IS_VAR == IS_VAR && !container) {
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
+
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
        if (0) {
                zval_ptr_dtor(&property);
        } else {
 
        }
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
        /* We are going to assign the result by reference */
        if (opline->extended_value & ZEND_FETCH_MAKE_REF) {
-               Z_DELREF_PP(EX_T(opline->result.var).var.ptr_ptr);
-               SEPARATE_ZVAL_TO_MAKE_IS_REF(EX_T(opline->result.var).var.ptr_ptr);
-               Z_ADDREF_PP(EX_T(opline->result.var).var.ptr_ptr);
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+
+               Z_DELREF_PP(retval_ptr);
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
+               Z_ADDREF_PP(retval_ptr);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *property = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *property;
+       zval **container;
+
+       SAVE_OPLINE();
+       property = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
        if (0) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       if (IS_VAR == IS_VAR && !container) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_RW TSRMLS_CC);
@@ -16335,37 +17424,84 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HAND
        } else {
 
        }
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_property_address_read_helper_SPEC_VAR_CV(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       USE_OPLINE
+       zend_free_op free_op1;
+       zval *container;
+
+       zval *offset;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       offset  = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               if (RETURN_VALUE_USED(opline)) {
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+               }
+
+       } else {
+               zval *retval;
+
+               if (0) {
+                       MAKE_REAL_ZVAL_PTR(offset);
+               }
+
+               /* here we are sure we are dealing with an object */
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+
+               if (!RETURN_VALUE_USED(opline)) {
+                       if (Z_REFCOUNT_P(retval) == 0) {
+                               GC_REMOVE_ZVAL_FROM_BUFFER(retval);
+                               zval_dtor(retval);
+                               FREE_ZVAL(retval);
+                       }
+               } else {
+                       PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
+               }
+
+               if (0) {
+                       zval_ptr_dtor(&offset);
+               } else {
+
+               }
+       }
+
+       if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        if (ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))) {
                /* Behave like FETCH_OBJ_W */
                zend_free_op free_op1;
-               zval *property = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-               zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+               zval *property;
+               zval **container;
+
+               SAVE_OPLINE();
+               property = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+               container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
                if (0) {
                        MAKE_REAL_ZVAL_PTR(property);
                }
-               if (IS_VAR == IS_VAR && !container) {
+               if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
                }
                zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
@@ -16374,27 +17510,27 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_VAR_CV_HANDLER(ZEND_OPCOD
                } else {
 
                }
-               if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-                   READY_TO_DESTROY(free_op1.var)) {
-                       AI_USE_PTR(EX_T(opline->result.var).var);
-                       if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                           Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                               SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-                       }
+               if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+                       EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
                }
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
-               return zend_fetch_property_address_read_helper_SPEC_VAR_CV(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_fetch_property_address_read_helper_SPEC_VAR_CV(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_res;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       zval *property = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       zval **container;
+       zval *property;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       property = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
 
        if (IS_VAR == IS_CV) {
                if (container != &EG(uninitialized_zval_ptr)) {
@@ -16404,7 +17540,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_H
        if (0) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       if (IS_VAR == IS_VAR && !container) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_UNSET TSRMLS_CC);
@@ -16413,13 +17549,8 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_H
        } else {
 
        }
-       if (IS_VAR == IS_VAR && (free_op1.var != NULL) &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_VAR == IS_VAR && (free_op1.var != NULL) && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
@@ -16429,24 +17560,28 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_H
        }
        PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
        FREE_OP_VAR_PTR(free_res);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       zval *property_name = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       zval **object_ptr;
+       zval *property_name;
+
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       property_name = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
 
        if (0) {
                MAKE_REAL_ZVAL_PTR(property_name);
        }
-       if (IS_VAR == IS_VAR && !object_ptr) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, op_data->op1_type, &op_data->op1, EX(Ts), ZEND_ASSIGN_OBJ, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), ZEND_ASSIGN_OBJ, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
        if (0) {
                zval_ptr_dtor(&property_name);
        } else {
@@ -16454,28 +17589,31 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLE
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **object_ptr;
 
-       if (IS_VAR == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
+       if (IS_VAR == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
        if (Z_TYPE_PP(object_ptr) == IS_OBJECT) {
 
-               zval *property_name = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+               zval *property_name = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
 
                if (0) {
                        MAKE_REAL_ZVAL_PTR(property_name);
                }
-               zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, op_data->op1_type, &op_data->op1, EX(Ts), ZEND_ASSIGN_DIM, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+               zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), ZEND_ASSIGN_DIM, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
                if (0) {
                        zval_ptr_dtor(&property_name);
                } else {
@@ -16484,30 +17622,44 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLE
        } else {
                zend_free_op free_op_data1, free_op_data2;
                zval *value;
-               zval *dim = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+               zval *dim = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
                zval **variable_ptr_ptr;
 
-               zend_fetch_dimension_address(&EX_T(op_data->op2.var), object_ptr, dim, IS_CV, BP_VAR_W TSRMLS_CC);
+               zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), object_ptr, dim, IS_CV, BP_VAR_W TSRMLS_CC);
 
-               value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-               variable_ptr_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-               if (!variable_ptr_ptr) {
-                       if (zend_assign_to_string_offset(&EX_T(op_data->op2.var), value, op_data->op1_type TSRMLS_CC)) {
+               value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+               variable_ptr_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
+               if (UNEXPECTED(variable_ptr_ptr == NULL)) {
+                       if (zend_assign_to_string_offset(&EX_T((opline+1)->op2.var), value, (opline+1)->op1_type TSRMLS_CC)) {
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-                                       ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                                       INIT_PZVAL(EX_T(opline->result.var).var.ptr);
-                                       ZVAL_STRINGL(EX_T(opline->result.var).var.ptr, Z_STRVAL_P(EX_T(op_data->op2.var).str_offset.str)+EX_T(op_data->op2.var).str_offset.offset, 1, 1);
+                                       zval *retval;
+
+                                       ALLOC_ZVAL(retval);
+                                       ZVAL_STRINGL(retval, Z_STRVAL_P(EX_T((opline+1)->op2.var).str_offset.str)+EX_T((opline+1)->op2.var).str_offset.offset, 1, 1);
+                                       INIT_PZVAL(retval);
+                                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                                }
                        } else if (RETURN_VALUE_USED(opline)) {
-                               AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                               PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+                       }
+               } else if (UNEXPECTED(*variable_ptr_ptr == &EG(error_zval))) {
+                       if (IS_TMP_FREE(free_op_data1)) {
+                               zval_dtor(value);
+                       }
+                       if (RETURN_VALUE_USED(opline)) {
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                        }
                } else {
-                       value = zend_assign_to_variable(variable_ptr_ptr, value, IS_TMP_FREE(free_op_data1) TSRMLS_CC);
+                       if (IS_TMP_FREE(free_op_data1)) {
+                               value = zend_assign_tmp_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+                       } else {
+                               value = zend_assign_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+                       }
                        if (RETURN_VALUE_USED(opline)) {
-                               AI_SET_PTR(EX_T(opline->result.var).var, value);
                                PZVAL_LOCK(value);
+                               AI_SET_PTR(&EX_T(opline->result.var), value);
                        }
                }
                FREE_OP_VAR_PTR(free_op_data2);
@@ -16515,34 +17667,53 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLE
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        /* assign_dim has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *value = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-       zval **variable_ptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval *value;
+       zval **variable_ptr_ptr;
+
+       SAVE_OPLINE();
+       value = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+       variable_ptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (IS_VAR == IS_VAR && !variable_ptr_ptr) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(variable_ptr_ptr == NULL)) {
                if (zend_assign_to_string_offset(&EX_T(opline->op1.var), value, IS_CV TSRMLS_CC)) {
                        if (RETURN_VALUE_USED(opline)) {
-                               EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-                               ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                               INIT_PZVAL(EX_T(opline->result.var).var.ptr);
-                               ZVAL_STRINGL(EX_T(opline->result.var).var.ptr, Z_STRVAL_P(EX_T(opline->op1.var).str_offset.str)+EX_T(opline->op1.var).str_offset.offset, 1, 1);
+                               zval *retval;
+
+                               ALLOC_ZVAL(retval);
+                               ZVAL_STRINGL(retval, Z_STRVAL_P(EX_T(opline->op1.var).str_offset.str)+EX_T(opline->op1.var).str_offset.offset, 1, 1);
+                               INIT_PZVAL(retval);
+                               AI_SET_PTR(&EX_T(opline->result.var), retval);
                        }
                } else if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+               }
+       } else if (IS_VAR == IS_VAR && UNEXPECTED(*variable_ptr_ptr == &EG(error_zval))) {
+               if (0) {
+                       zval_dtor(value);
+               }
+               if (RETURN_VALUE_USED(opline)) {
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
        } else {
-               value = zend_assign_to_variable(variable_ptr_ptr, value, 0 TSRMLS_CC);
+               if (0) {
+                       value = zend_assign_tmp_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+               } else {
+                       value = zend_assign_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+               }
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, value);
                        PZVAL_LOCK(value);
+                       AI_SET_PTR(&EX_T(opline->result.var), value);
                }
        }
 
@@ -16550,15 +17721,19 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_AR
 
        /* zend_assign_to_variable() always takes care of op2, never free it! */
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_REF_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
        zval **variable_ptr_ptr;
-       zval **value_ptr_ptr = _get_zval_ptr_ptr_cv(opline->op2.var, BP_VAR_W TSRMLS_CC);
+       zval **value_ptr_ptr;
+
+       SAVE_OPLINE();
+       value_ptr_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op2.var TSRMLS_CC);
 
        if (IS_CV == IS_VAR &&
            value_ptr_ptr &&
@@ -16571,19 +17746,19 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_REF_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLE
                zend_error(E_STRICT, "Only variables should be assigned by reference");
                if (UNEXPECTED(EG(exception) != NULL)) {
 
-                       ZEND_VM_NEXT_OPCODE();
+                       HANDLE_EXCEPTION();
                }
                return ZEND_ASSIGN_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (IS_CV == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
                PZVAL_LOCK(*value_ptr_ptr);
        }
-       if (IS_VAR == IS_VAR && EX_T(opline->op1.var).var.ptr_ptr == &EX_T(opline->op1.var).var.ptr) {
+       if (IS_VAR == IS_VAR && UNEXPECTED(EX_T(opline->op1.var).var.ptr_ptr == &EX_T(opline->op1.var).var.ptr)) {
                zend_error_noreturn(E_ERROR, "Cannot assign by reference to overloaded object");
        }
 
-       variable_ptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       if ((IS_CV == IS_VAR && !value_ptr_ptr) ||
-           (IS_VAR == IS_VAR && !variable_ptr_ptr)) {
+       variable_ptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       if ((IS_CV == IS_VAR && UNEXPECTED(value_ptr_ptr == NULL)) ||
+           (IS_VAR == IS_VAR && UNEXPECTED(variable_ptr_ptr == NULL))) {
                zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
        }
        zend_assign_to_variable_reference(variable_ptr_ptr, value_ptr_ptr TSRMLS_CC);
@@ -16593,44 +17768,48 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_REF_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLE
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *variable_ptr_ptr);
                PZVAL_LOCK(*variable_ptr_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *variable_ptr_ptr);
        }
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        char *function_name_strval;
        int function_name_strlen;
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
-       function_name = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       function_name = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
 
-       if (Z_TYPE_P(function_name)!=IS_STRING) {
+       if (IS_CV != IS_CONST &&
+           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                zend_error_noreturn(E_ERROR, "Method name must be a string");
        }
 
        function_name_strval = Z_STRVAL_P(function_name);
        function_name_strlen = Z_STRLEN_P(function_name);
 
-       EX(object) = _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       EX(object) = _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (EX(object) && Z_TYPE_P(EX(object)) == IS_OBJECT) {
-               if (Z_OBJ_HT_P(EX(object))->get_method == NULL) {
+       if (EXPECTED(EX(object) != NULL) &&
+           EXPECTED(Z_TYPE_P(EX(object)) == IS_OBJECT)) {
+               if (UNEXPECTED(Z_OBJ_HT_P(EX(object))->get_method == NULL)) {
                        zend_error_noreturn(E_ERROR, "Object does not support method calls");
                }
 
                /* First, locate the function. */
                EX(fbc) = Z_OBJ_HT_P(EX(object))->get_method(&EX(object), function_name_strval, function_name_strlen, ((IS_CV == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
-               if (!EX(fbc)) {
+               if (UNEXPECTED(EX(fbc) == NULL)) {
                        zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", Z_OBJ_CLASS_NAME_P(EX(object)), function_name_strval);
                }
 
@@ -16655,21 +17834,23 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        zend_class_entry *ce;
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
        if (IS_VAR == IS_CONST) {
                /* no function found. try a static method in class */
                ce = zend_fetch_class_by_name(Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), opline->op1.literal + 1, opline->extended_value TSRMLS_CC);
-               if (!ce) {
+               if (UNEXPECTED(ce == NULL)) {
                        zend_error_noreturn(E_ERROR, "Class '%s' not found", Z_STRVAL_P(opline->op1.zv));
                }
                EX(called_scope) = ce;
@@ -16691,9 +17872,9 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_CV_HANDLER(ZEND_
                        function_name_strval = Z_STRVAL_P(opline->op2.zv);
                        function_name_strlen = Z_STRLEN_P(opline->op2.zv);
                } else {
-                       function_name = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+                       function_name = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
 
-                       if (Z_TYPE_P(function_name) != IS_STRING) {
+                       if (UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                                zend_error_noreturn(E_ERROR, "Function name must be a string");
                        } else {
                                function_name_strval = Z_STRVAL_P(function_name);
@@ -16707,7 +17888,7 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_CV_HANDLER(ZEND_
                        } else {
                                EX(fbc) = zend_std_get_static_method(ce, function_name_strval, function_name_strlen, ((IS_CV == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
                        }
-                       if (!EX(fbc)) {
+                       if (UNEXPECTED(EX(fbc) == NULL)) {
                                zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", ce->name, function_name_strval);
                        }
                }
@@ -16716,11 +17897,11 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_CV_HANDLER(ZEND_
 
                }
        } else {
-               if(!ce->constructor) {
+               if (UNEXPECTED(ce->constructor == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot call constructor");
                }
                if (EG(This) && Z_OBJCE_P(EG(This)) != ce->constructor->common.scope && (ce->constructor->common.fn_flags & ZEND_ACC_PRIVATE)) {
-                       zend_error(E_COMPILE_ERROR, "Cannot call private %s::__construct()", ce->name);
+                       zend_error_noreturn(E_ERROR, "Cannot call private %s::__construct()", ce->name);
                }
                EX(fbc) = ce->constructor;
        }
@@ -16752,15 +17933,17 @@ static int ZEND_FASTCALL  ZEND_INIT_STATIC_METHOD_CALL_SPEC_VAR_CV_HANDLER(ZEND_
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CASE_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        int switch_expr_is_overloaded=0;
        zend_free_op free_op1;
 
+       SAVE_OPLINE();
        if (IS_VAR==IS_VAR) {
                if (EX_T(opline->op1.var).var.ptr_ptr) {
                        PZVAL_LOCK(EX_T(opline->op1.var).var.ptr);
@@ -16770,8 +17953,8 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS
                }
        }
        is_equal_function(&EX_T(opline->result.var).tmp_var,
-                                _get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC),
-                                _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+                                _get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC),
+                                _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
        if (switch_expr_is_overloaded) {
                /* We only free op1 if this is a string offset,
@@ -16783,47 +17966,32 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS
                EX_T(opline->op1.var).var.ptr_ptr = NULL;
                EX_T(opline->op1.var).var.ptr = NULL;
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *array_ptr = &EX_T(opline->result.var).tmp_var;
        zval *expr_ptr;
-       zval *offset=_get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-       ulong hval;
-       long index;
 
-#if 0 || IS_VAR == IS_VAR || IS_VAR == IS_CV
-       zval **expr_ptr_ptr = NULL;
+       SAVE_OPLINE();
+       if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && opline->extended_value) {
+               zval **expr_ptr_ptr = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
 
-       if (opline->extended_value) {
-               expr_ptr_ptr=_get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
                expr_ptr = *expr_ptr_ptr;
+               Z_ADDREF_P(expr_ptr);
        } else {
-               expr_ptr=_get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       }
-#else
-       expr_ptr=_get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-#endif
-
-       if (0) { /* temporary variable */
-               zval *new_expr;
+               expr_ptr=_get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+               if (0) { /* temporary variable */
+                       zval *new_expr;
 
-               ALLOC_ZVAL(new_expr);
-               INIT_PZVAL_COPY(new_expr, expr_ptr);
-               expr_ptr = new_expr;
-       } else {
-#if 0 || IS_VAR == IS_VAR || IS_VAR == IS_CV
-               if (opline->extended_value) {
-                       SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
-                       expr_ptr = *expr_ptr_ptr;
-                       Z_ADDREF_P(expr_ptr);
-               } else
-#endif
-               if (IS_VAR == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
+                       ALLOC_ZVAL(new_expr);
+                       INIT_PZVAL_COPY(new_expr, expr_ptr);
+                       expr_ptr = new_expr;
+               } else if (IS_VAR == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
                        zval *new_expr;
 
                        ALLOC_ZVAL(new_expr);
@@ -16834,7 +18002,13 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_CV_HANDLER(ZEND_OPCODE
                        Z_ADDREF_P(expr_ptr);
                }
        }
-       if (offset) {
+
+       if (IS_CV != IS_UNUSED) {
+
+               zval *offset = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+               ulong hval;
+               long index;
+
                switch (Z_TYPE_P(offset)) {
                        case IS_DOUBLE:
                                index = zend_dval_to_lval(Z_DVAL_P(offset));
@@ -16843,7 +18017,7 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_VAR_CV_HANDLER(ZEND_OPCODE
                        case IS_BOOL:
                                index = Z_LVAL_P(offset);
 num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(array_ptr), index, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_index_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), index, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_STRING:
                                if (IS_CV == IS_CONST) {
@@ -16856,10 +18030,10 @@ num_index:
                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                        }
                                }
-                               zend_hash_quick_update(Z_ARRVAL_P(array_ptr), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_quick_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_NULL:
-                               zend_hash_update(Z_ARRVAL_P(array_ptr), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
                                break;
                        default:
                                zend_error(E_WARNING, "Illegal offset type");
@@ -16869,19 +18043,20 @@ num_index:
                }
 
        } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(array_ptr), &expr_ptr, sizeof(zval *), NULL);
+               zend_hash_next_index_insert(Z_ARRVAL(EX_T(opline->result.var).tmp_var), &expr_ptr, sizeof(zval *), NULL);
        }
-       if (opline->extended_value) {
+       if ((IS_VAR == IS_VAR || IS_VAR == IS_CV) && opline->extended_value) {
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        } else {
                if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (IS_VAR == IS_UNUSED) {
@@ -16895,13 +18070,17 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLE
 
 static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       zval *offset = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       zval **container;
+       zval *offset;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       offset = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+
        if (IS_VAR != IS_VAR || container) {
                if (IS_VAR == IS_CV && container != &EG(uninitialized_zval_ptr)) {
                        SEPARATE_ZVAL_IF_NOT_REF(container);
@@ -16935,24 +18114,10 @@ num_index_dim:
                                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                                        }
                                                }
-                                               if (zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval) == SUCCESS &&
-                                           ht == &EG(symbol_table)) {
-                                                       zend_execute_data *ex;
-
-                                                       for (ex = execute_data; ex; ex = ex->prev_execute_data) {
-                                                               if (ex->op_array && ex->symbol_table == ht) {
-                                                                       int i;
-
-                                                                       for (i = 0; i < ex->op_array->last_var; i++) {
-                                                                               if (ex->op_array->vars[i].hash_value == hval &&
-                                                                                   ex->op_array->vars[i].name_len == offset->value.str.len &&
-                                                                                   !memcmp(ex->op_array->vars[i].name, offset->value.str.val, offset->value.str.len)) {
-                                                                                       ex->CVs[i] = NULL;
-                                                                                       break;
-                                                                               }
-                                                                       }
-                                                               }
-                                                       }
+                                               if (ht == &EG(symbol_table)) {
+                                                       zend_delete_global_variable_ex(offset->value.str.val, offset->value.str.len, hval TSRMLS_CC);
+                                               } else {
+                                                       zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval);
                                                }
                                                if (IS_CV == IS_CV || IS_CV == IS_VAR) {
                                                        zval_ptr_dtor(&offset);
@@ -16969,7 +18134,7 @@ num_index_dim:
                                break;
                        }
                        case IS_OBJECT:
-                               if (!Z_OBJ_HT_P(*container)->unset_dimension) {
+                               if (UNEXPECTED(Z_OBJ_HT_P(*container)->unset_dimension == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use object as array");
                                }
                                if (0) {
@@ -16994,15 +18159,20 @@ num_index_dim:
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
-       zval *offset = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       zval **container;
+       zval *offset;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+       offset = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
 
        if (IS_VAR != IS_VAR || container) {
                if (IS_VAR == IS_CV && container != &EG(uninitialized_zval_ptr)) {
@@ -17030,22 +18200,26 @@ static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_VAR_CV_HANDLER(ZEND_OPCODE_HANDLER
        }
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_isset_isempty_dim_prop_obj_handler_SPEC_VAR_CV(int prop_dim, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **container = _get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC);
+       zval **container;
        zval **value = NULL;
        int result = 0;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC);
+
        if (IS_VAR != IS_VAR || container) {
 
-               zval *offset = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+               zval *offset = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
 
                if (Z_TYPE_PP(container) == IS_ARRAY && !prop_dim) {
                        HashTable *ht;
@@ -17136,7 +18310,7 @@ num_index_prop:
                        zval tmp;
 
                        if (Z_TYPE_P(offset) != IS_LONG) {
-                               tmp = *offset;
+                               ZVAL_COPY_VALUE(&tmp, offset);
                                zval_copy_ctor(&tmp);
                                convert_to_long(&tmp);
                                offset = &tmp;
@@ -17159,15 +18333,15 @@ num_index_prop:
        }
 
        Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
-
        if (opline->extended_value & ZEND_ISSET) {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = result;
-       } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+       } else {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = !result;
        }
 
        if (free_op1.var) {zval_ptr_dtor(&free_op1.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -17183,23 +18357,26 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_VAR_CV_HANDLER(ZEND_O
 
 static int ZEND_FASTCALL  ZEND_CLONE_SPEC_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *obj = _get_obj_zval_ptr_unused(TSRMLS_C);
+       zval *obj;
        zend_class_entry *ce;
        zend_function *clone;
        zend_object_clone_obj_t clone_call;
 
+       SAVE_OPLINE();
+       obj = _get_obj_zval_ptr_unused(TSRMLS_C);
+
        if (IS_UNUSED == IS_CONST ||
-           (IS_UNUSED == IS_VAR && !obj) ||
-           Z_TYPE_P(obj) != IS_OBJECT) {
+           (IS_UNUSED == IS_VAR && UNEXPECTED(obj == NULL)) ||
+           UNEXPECTED(Z_TYPE_P(obj) != IS_OBJECT)) {
                zend_error_noreturn(E_ERROR, "__clone method called on non-object");
        }
 
        ce = Z_OBJCE_P(obj);
        clone = ce ? ce->clone : NULL;
        clone_call =  Z_OBJ_HT_P(obj)->clone_obj;
-       if (!clone_call) {
+       if (UNEXPECTED(clone_call == NULL)) {
                if (ce) {
                        zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object of class %s", ce->name);
                } else {
@@ -17211,37 +18388,43 @@ static int ZEND_FASTCALL  ZEND_CLONE_SPEC_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARG
                if (clone->op_array.fn_flags & ZEND_ACC_PRIVATE) {
                        /* Ensure that if we're calling a private function, we're allowed to do so.
                         */
-                       if (ce != EG(scope)) {
+                       if (UNEXPECTED(ce != EG(scope))) {
                                zend_error_noreturn(E_ERROR, "Call to private %s::__clone() from context '%s'", ce->name, EG(scope) ? EG(scope)->name : "");
                        }
                } else if ((clone->common.fn_flags & ZEND_ACC_PROTECTED)) {
                        /* Ensure that if we're calling a protected function, we're allowed to do so.
                         */
-                       if (!zend_check_protected(clone->common.scope, EG(scope))) {
+                       if (UNEXPECTED(!zend_check_protected(clone->common.scope, EG(scope)))) {
                                zend_error_noreturn(E_ERROR, "Call to protected %s::__clone() from context '%s'", ce->name, EG(scope) ? EG(scope)->name : "");
                        }
                }
        }
 
-       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-       if (!EG(exception)) {
-               ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-               Z_OBJVAL_P(EX_T(opline->result.var).var.ptr) = clone_call(obj TSRMLS_CC);
-               Z_TYPE_P(EX_T(opline->result.var).var.ptr) = IS_OBJECT;
-               Z_SET_REFCOUNT_P(EX_T(opline->result.var).var.ptr, 1);
-               Z_SET_ISREF_P(EX_T(opline->result.var).var.ptr);
-               if (!RETURN_VALUE_USED(opline) || EG(exception)) {
-                       zval_ptr_dtor(&EX_T(opline->result.var).var.ptr);
+       if (EXPECTED(EG(exception) == NULL)) {
+               zval *retval;
+
+               ALLOC_ZVAL(retval);
+               Z_OBJVAL_P(retval) = clone_call(obj TSRMLS_CC);
+               Z_TYPE_P(retval) = IS_OBJECT;
+               Z_SET_REFCOUNT_P(retval, 1);
+               Z_SET_ISREF_P(retval);
+               if (!RETURN_VALUE_USED(opline) || UNEXPECTED(EG(exception) != NULL)) {
+                       zval_ptr_dtor(&retval);
+               } else {
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_EXIT_SPEC_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
 #if 0 || (IS_UNUSED != IS_UNUSED)
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       SAVE_OPLINE();
        if (IS_UNUSED != IS_UNUSED) {
 
                zval *ptr = NULL;
@@ -17255,38 +18438,36 @@ static int ZEND_FASTCALL  ZEND_EXIT_SPEC_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS
        }
 #endif
        zend_bailout();
-       ZEND_VM_NEXT_OPCODE();
+       ZEND_VM_NEXT_OPCODE(); /* Never reached */
 }
 
 static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op_data1;
        zval **object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
        zval *object;
        zval *property = opline->op2.zv;
-       zval *value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
+       zval *value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
        znode_op *result = &opline->result;
        int have_get_ptr = 0;
 
-       if (IS_UNUSED == IS_VAR && !object_ptr) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
 
-       EX_T(result->var).var.ptr_ptr = NULL;
        make_real_object(object_ptr TSRMLS_CC);
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to assign property of non-object");
 
                FREE_OP(free_op_data1);
 
                if (RETURN_VALUE_USED(opline)) {
-                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                       EX_T(result->var).var.ptr_ptr = NULL;
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                }
        } else {
                /* here we are sure we are dealing with an object */
@@ -17304,9 +18485,9 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(int
                                have_get_ptr = 1;
                                binary_op(*zptr, *zptr, value TSRMLS_CC);
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = *zptr;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(*zptr);
+                                       EX_T(opline->result.var).var.ptr = *zptr;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -17343,17 +18524,17 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(int
                                        Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
                                }
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = z;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(z);
+                                       EX_T(opline->result.var).var.ptr = z;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                                zval_ptr_dtor(&z);
                        } else {
                                zend_error(E_WARNING, "Attempt to assign property of non-object");
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                                       EX_T(result->var).var.ptr_ptr = NULL;
-                                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                                       PZVAL_LOCK(&EG(uninitialized_zval));
+                                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -17367,17 +18548,19 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(int
        }
 
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op_data2, free_op_data1;
        zval **var_ptr;
        zval *value;
 
+       SAVE_OPLINE();
        switch (opline->extended_value) {
                case ZEND_ASSIGN_OBJ:
                        return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
@@ -17385,21 +18568,19 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_CONST(int (*bi
                case ZEND_ASSIGN_DIM: {
                                zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
 
-                               if (IS_UNUSED == IS_VAR && !container) {
+                               if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-                               } else if (Z_TYPE_PP(container) == IS_OBJECT) {
+                               } else if (UNEXPECTED(Z_TYPE_PP(container) == IS_OBJECT)) {
                                        if (IS_UNUSED == IS_VAR && !0) {
                                                Z_ADDREF_PP(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
                                        }
                                        return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CONST(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                                } else {
-                                       zend_op *op_data = opline+1;
                                        zval *dim = opline->op2.zv;
 
-                                       zend_fetch_dimension_address(&EX_T(op_data->op2.var), container, dim, IS_CONST, BP_VAR_RW TSRMLS_CC);
-                                       value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-                                       var_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-                                       ZEND_VM_INC_OPCODE();
+                                       zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), container, dim, IS_CONST, BP_VAR_RW TSRMLS_CC);
+                                       value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+                                       var_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
                                }
                        }
                        break;
@@ -17410,23 +18591,28 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_CONST(int (*bi
                        break;
        }
 
-       if (!var_ptr) {
+       if (UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
        }
 
-       if (*var_ptr == EG(error_zval_ptr)) {
+       if (UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
 
 
+               CHECK_EXCEPTION();
+               if (opline->extended_value == ZEND_ASSIGN_DIM) {
+                       ZEND_VM_INC_OPCODE();
+               }
                ZEND_VM_NEXT_OPCODE();
        }
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *objval = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -17439,15 +18625,20 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_CONST(int (*bi
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *var_ptr);
                PZVAL_LOCK(*var_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *var_ptr);
        }
 
        if (opline->extended_value == ZEND_ASSIGN_DIM) {
                FREE_OP(free_op_data1);
                FREE_OP_VAR_PTR(free_op_data2);
-       }
 
+               CHECK_EXCEPTION();
+               ZEND_VM_INC_OPCODE();
+       } else {
+
+               CHECK_EXCEPTION();
+       }
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -17508,29 +18699,35 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCO
 
 static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval **object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       zval **object_ptr;
        zval *object;
-       zval *property = opline->op2.zv;
-       zval **retval = &EX_T(opline->result.var).var.ptr;
+       zval *property;
+       zval **retval;
        int have_get_ptr = 0;
 
-       if (IS_UNUSED == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       property = opline->op2.zv;
+       retval = &EX_T(opline->result.var).var.ptr;
+
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
 
                if (RETURN_VALUE_USED(opline)) {
-                       *retval = EG(uninitialized_zval_ptr);
-                       PZVAL_LOCK(*retval);
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       *retval = &EG(uninitialized_zval);
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -17558,7 +18755,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_CONST(incde
                if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -17578,8 +18775,8 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_CONST(incde
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                        if (RETURN_VALUE_USED(opline)) {
-                               *retval = EG(uninitialized_zval_ptr);
-                               PZVAL_LOCK(*retval);
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               *retval = &EG(uninitialized_zval);
                        }
                }
        }
@@ -17590,6 +18787,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_CONST(incde
 
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -17605,26 +18803,32 @@ static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE
 
 static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval **object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       zval **object_ptr;
        zval *object;
-       zval *property = opline->op2.zv;
-       zval *retval = &EX_T(opline->result.var).tmp_var;
+       zval *property;
+       zval *retval;
        int have_get_ptr = 0;
 
-       if (IS_UNUSED == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       property = opline->op2.zv;
+       retval = &EX_T(opline->result.var).tmp_var;
+
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
 
-               *retval = *EG(uninitialized_zval_ptr);
+               ZVAL_NULL(retval);
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -17640,7 +18844,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_CONST(incd
                        have_get_ptr = 1;
                        SEPARATE_ZVAL_IF_NOT_REF(zptr);
 
-                       *retval = **zptr;
+                       ZVAL_COPY_VALUE(retval, *zptr);
                        zendi_zval_copy_ctor(*retval);
 
                        incdec_op(*zptr);
@@ -17653,7 +18857,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_CONST(incd
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
                        zval *z_copy;
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -17663,12 +18867,11 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_CONST(incd
                                }
                                z = value;
                        }
-                       *retval = *z;
+                       ZVAL_COPY_VALUE(retval, z);
                        zendi_zval_copy_ctor(*retval);
                        ALLOC_ZVAL(z_copy);
-                       *z_copy = *z;
+                       INIT_PZVAL_COPY(z_copy, z);
                        zendi_zval_copy_ctor(*z_copy);
-                       INIT_PZVAL(z_copy);
                        incdec_op(z_copy);
                        Z_ADDREF_P(z);
                        Z_OBJ_HT_P(object)->write_property(object, property, z_copy, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
@@ -17676,7 +18879,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_CONST(incd
                        zval_ptr_dtor(&z);
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-                       *retval = *EG(uninitialized_zval_ptr);
+                       ZVAL_NULL(retval);
                }
        }
 
@@ -17686,6 +18889,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_CONST(incd
 
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -17699,21 +18903,24 @@ static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCOD
        return zend_post_incdec_property_helper_SPEC_UNUSED_CONST(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_UNUSED_CONST(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_UNUSED_CONST(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *container = _get_obj_zval_ptr_unused(TSRMLS_C);
+       zval *container;
 
-       zval *offset  = opline->op2.zv;
+       zval *offset;
 
-       if (Z_TYPE_P(container) != IS_OBJECT || !Z_OBJ_HT_P(container)->read_property) {
-               if (type != BP_VAR_IS) {
-                       zend_error(E_NOTICE, "Trying to get property of non-object");
-               }
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_unused(TSRMLS_C);
+       offset  = opline->op2.zv;
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               zend_error(E_NOTICE, "Trying to get property of non-object");
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
 
        } else {
@@ -17724,7 +18931,7 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_UNUSED_CON
                }
 
                /* here we are sure we are dealing with an object */
-               retval = Z_OBJ_HT_P(container)->read_property(container, offset, type, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
                if (!RETURN_VALUE_USED(opline)) {
                        if (Z_REFCOUNT_P(retval) == 0) {
@@ -17733,8 +18940,8 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_UNUSED_CON
                                FREE_ZVAL(retval);
                        }
                } else {
-                       AI_SET_PTR(EX_T(opline->result.var).var, retval);
                        PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                }
 
                if (0) {
@@ -17744,21 +18951,25 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_UNUSED_CON
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_property_address_read_helper_SPEC_UNUSED_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_fetch_property_address_read_helper_SPEC_UNUSED_CONST(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *property = opline->op2.zv;
+       zval *property;
        zval **container;
 
+       SAVE_OPLINE();
+       property = opline->op2.zv;
+
        if (IS_UNUSED == IS_VAR && (opline->extended_value & ZEND_FETCH_ADD_LOCK)) {
                PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
                EX_T(opline->op1.var).var.ptr = *EX_T(opline->op1.var).var.ptr_ptr;
@@ -17768,45 +18979,48 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE
                MAKE_REAL_ZVAL_PTR(property);
        }
        container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
-       if (IS_UNUSED == IS_VAR && !container) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
+
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
        if (0) {
                zval_ptr_dtor(&property);
        } else {
 
        }
-       if (IS_UNUSED == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_UNUSED == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
        /* We are going to assign the result by reference */
        if (opline->extended_value & ZEND_FETCH_MAKE_REF) {
-               Z_DELREF_PP(EX_T(opline->result.var).var.ptr_ptr);
-               SEPARATE_ZVAL_TO_MAKE_IS_REF(EX_T(opline->result.var).var.ptr_ptr);
-               Z_ADDREF_PP(EX_T(opline->result.var).var.ptr_ptr);
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+
+               Z_DELREF_PP(retval_ptr);
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
+               Z_ADDREF_PP(retval_ptr);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *property = opline->op2.zv;
-       zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       zval *property;
+       zval **container;
+
+       SAVE_OPLINE();
+       property = opline->op2.zv;
+       container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
 
        if (0) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       if (IS_UNUSED == IS_VAR && !container) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_RW TSRMLS_CC);
@@ -17815,37 +19029,83 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCOD
        } else {
 
        }
-       if (IS_UNUSED == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_UNUSED == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_property_address_read_helper_SPEC_UNUSED_CONST(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       USE_OPLINE
+
+       zval *container;
+
+       zval *offset;
+
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_unused(TSRMLS_C);
+       offset  = opline->op2.zv;
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               if (RETURN_VALUE_USED(opline)) {
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+               }
+
+       } else {
+               zval *retval;
+
+               if (0) {
+                       MAKE_REAL_ZVAL_PTR(offset);
+               }
+
+               /* here we are sure we are dealing with an object */
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+
+               if (!RETURN_VALUE_USED(opline)) {
+                       if (Z_REFCOUNT_P(retval) == 0) {
+                               GC_REMOVE_ZVAL_FROM_BUFFER(retval);
+                               zval_dtor(retval);
+                               FREE_ZVAL(retval);
+                       }
+               } else {
+                       PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
+               }
+
+               if (0) {
+                       zval_ptr_dtor(&offset);
+               } else {
+
+               }
+       }
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        if (ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))) {
                /* Behave like FETCH_OBJ_W */
                zend_free_op free_op1;
-               zval *property = opline->op2.zv;
-               zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+               zval *property;
+               zval **container;
+
+               SAVE_OPLINE();
+               property = opline->op2.zv;
+               container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
 
                if (0) {
                        MAKE_REAL_ZVAL_PTR(property);
                }
-               if (IS_UNUSED == IS_VAR && !container) {
+               if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
                }
                zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
@@ -17854,27 +19114,27 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_CONST_HANDLER(ZEND
                } else {
 
                }
-               if (IS_UNUSED == IS_VAR && 0 &&
-                   READY_TO_DESTROY(free_op1.var)) {
-                       AI_USE_PTR(EX_T(opline->result.var).var);
-                       if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                           Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                               SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-                       }
+               if (IS_UNUSED == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+                       EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
-               return zend_fetch_property_address_read_helper_SPEC_UNUSED_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_fetch_property_address_read_helper_SPEC_UNUSED_CONST(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_res;
-       zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
-       zval *property = opline->op2.zv;
+       zval **container;
+       zval *property;
+
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       property = opline->op2.zv;
 
        if (IS_UNUSED == IS_CV) {
                if (container != &EG(uninitialized_zval_ptr)) {
@@ -17884,7 +19144,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_CONST_HANDLER(ZEND_OP
        if (0) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       if (IS_UNUSED == IS_VAR && !container) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_UNSET TSRMLS_CC);
@@ -17893,13 +19153,8 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_CONST_HANDLER(ZEND_OP
        } else {
 
        }
-       if (IS_UNUSED == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_UNUSED == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
        PZVAL_UNLOCK(*EX_T(opline->result.var).var.ptr_ptr, &free_res);
@@ -17908,24 +19163,28 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_CONST_HANDLER(ZEND_OP
        }
        PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
        FREE_OP_VAR_PTR(free_res);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
 
-       zval **object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
-       zval *property_name = opline->op2.zv;
+       zval **object_ptr;
+       zval *property_name;
+
+       SAVE_OPLINE();
+       object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       property_name = opline->op2.zv;
 
        if (0) {
                MAKE_REAL_ZVAL_PTR(property_name);
        }
-       if (IS_UNUSED == IS_VAR && !object_ptr) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, op_data->op1_type, &op_data->op1, EX(Ts), ZEND_ASSIGN_OBJ, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), ZEND_ASSIGN_OBJ, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
        if (0) {
                zval_ptr_dtor(&property_name);
        } else {
@@ -17933,15 +19192,18 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_
        }
 
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_CHAR_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *str = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
+
        if (IS_UNUSED == IS_UNUSED) {
                /* Initialize for erealloc in add_char_to_string */
                Z_STRVAL_P(str) = NULL;
@@ -17954,14 +19216,17 @@ static int ZEND_FASTCALL  ZEND_ADD_CHAR_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HA
        add_char_to_string(str, str, opline->op2.zv);
 
        /* FREE_OP is missing intentionally here - we're always working on the same temporary variable */
+       /*CHECK_EXCEPTION();*/
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_STRING_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *str = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
+
        if (IS_UNUSED == IS_UNUSED) {
                /* Initialize for erealloc in add_string_to_string */
                Z_STRVAL_P(str) = NULL;
@@ -17974,22 +19239,25 @@ static int ZEND_FASTCALL  ZEND_ADD_STRING_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_
        add_string_to_string(str, str, opline->op2.zv);
 
        /* FREE_OP is missing intentionally here - we're always working on the same temporary variable */
+       /*CHECK_EXCEPTION();*/
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        char *function_name_strval;
        int function_name_strlen;
 
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
        function_name = opline->op2.zv;
 
-       if (Z_TYPE_P(function_name)!=IS_STRING) {
+       if (IS_CONST != IS_CONST &&
+           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                zend_error_noreturn(E_ERROR, "Method name must be a string");
        }
 
@@ -17998,14 +19266,15 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_CONST_HANDLER(ZEND_O
 
        EX(object) = _get_obj_zval_ptr_unused(TSRMLS_C);
 
-       if (EX(object) && Z_TYPE_P(EX(object)) == IS_OBJECT) {
-               if (Z_OBJ_HT_P(EX(object))->get_method == NULL) {
+       if (EXPECTED(EX(object) != NULL) &&
+           EXPECTED(Z_TYPE_P(EX(object)) == IS_OBJECT)) {
+               if (UNEXPECTED(Z_OBJ_HT_P(EX(object))->get_method == NULL)) {
                        zend_error_noreturn(E_ERROR, "Object does not support method calls");
                }
 
                /* First, locate the function. */
                EX(fbc) = Z_OBJ_HT_P(EX(object))->get_method(&EX(object), function_name_strval, function_name_strlen, ((IS_CONST == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
-               if (!EX(fbc)) {
+               if (UNEXPECTED(EX(fbc) == NULL)) {
                        zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", Z_OBJ_CLASS_NAME_P(EX(object)), function_name_strval);
                }
 
@@ -18029,13 +19298,15 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_CONST_HANDLER(ZEND_O
        }
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_CONSTANT_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
+       SAVE_OPLINE();
        if (IS_UNUSED == IS_UNUSED) {
                /* namespaced constant */
                if (!zend_get_constant_ex(Z_STRVAL_P(opline->op2.zv), Z_STRLEN_P(opline->op2.zv), &EX_T(opline->result.var).tmp_var, NULL, opline->extended_value TSRMLS_CC)) {
@@ -18050,10 +19321,10 @@ static int ZEND_FASTCALL  ZEND_FETCH_CONSTANT_SPEC_UNUSED_CONST_HANDLER(ZEND_OPC
                                zend_error(E_NOTICE, "Use of undefined constant %s - assumed '%s'", actual, actual);
                                ZVAL_STRINGL(&EX_T(opline->result.var).tmp_var, actual, Z_STRLEN_P(opline->op2.zv)-(actual - Z_STRVAL_P(opline->op2.zv)), 1);
                        } else {
-                               zend_error_noreturn(E_ERROR, "Undefined constant '%s'",
-                                                       Z_STRVAL_P(opline->op2.zv), Z_STRVAL_P(opline->op2.zv));
+                               zend_error_noreturn(E_ERROR, "Undefined constant '%s'", Z_STRVAL_P(opline->op2.zv));
                        }
                }
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
                /* class constant */
@@ -18063,14 +19334,14 @@ static int ZEND_FASTCALL  ZEND_FETCH_CONSTANT_SPEC_UNUSED_CONST_HANDLER(ZEND_OPC
                if (IS_UNUSED == IS_CONST) {
 
                        ce = zend_fetch_class_by_name(Z_STRVAL_P(opline->op1.zv), Z_STRLEN_P(opline->op1.zv), opline->op1.literal + 1, opline->extended_value TSRMLS_CC);
-                       if (!ce) {
+                       if (UNEXPECTED(ce == NULL)) {
                                zend_error_noreturn(E_ERROR, "Undefined class constant '%s'", Z_STRVAL_P(opline->op2.zv));
                        }
                } else {
                        ce = EX_T(opline->op1.var).class_entry;
                }
 
-               if (zend_hash_quick_find(&ce->constants_table, Z_STRVAL_P(opline->op2.zv), Z_STRLEN_P(opline->op2.zv)+1, Z_HASH_P(opline->op2.zv), (void **) &value) == SUCCESS) {
+               if (EXPECTED(zend_hash_quick_find(&ce->constants_table, Z_STRVAL_P(opline->op2.zv), Z_STRLEN_P(opline->op2.zv)+1, Z_HASH_P(opline->op2.zv), (void **) &value) == SUCCESS)) {
                        if (Z_TYPE_PP(value) == IS_CONSTANT_ARRAY ||
                            (Z_TYPE_PP(value) & IS_CONSTANT_TYPE_MASK) == IS_CONSTANT) {
                                zend_class_entry *old_scope = EG(scope);
@@ -18079,19 +19350,20 @@ static int ZEND_FASTCALL  ZEND_FETCH_CONSTANT_SPEC_UNUSED_CONST_HANDLER(ZEND_OPC
                                zval_update_constant(value, (void *) 1 TSRMLS_CC);
                                EG(scope) = old_scope;
                        }
-                       EX_T(opline->result.var).tmp_var = **value;
+                       ZVAL_COPY_VALUE(&EX_T(opline->result.var).tmp_var, *value);
                        zval_copy_ctor(&EX_T(opline->result.var).tmp_var);
                } else {
                        zend_error_noreturn(E_ERROR, "Undefined class constant '%s'", Z_STRVAL_P(opline->op2.zv));
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (IS_UNUSED == IS_UNUSED) {
@@ -18105,13 +19377,17 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_
 
 static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
-       zval *offset = opline->op2.zv;
+       zval **container;
+       zval *offset;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       offset = opline->op2.zv;
+
        if (IS_UNUSED != IS_VAR || container) {
                if (IS_UNUSED == IS_CV && container != &EG(uninitialized_zval_ptr)) {
                        SEPARATE_ZVAL_IF_NOT_REF(container);
@@ -18145,24 +19421,10 @@ num_index_dim:
                                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                                        }
                                                }
-                                               if (zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval) == SUCCESS &&
-                                           ht == &EG(symbol_table)) {
-                                                       zend_execute_data *ex;
-
-                                                       for (ex = execute_data; ex; ex = ex->prev_execute_data) {
-                                                               if (ex->op_array && ex->symbol_table == ht) {
-                                                                       int i;
-
-                                                                       for (i = 0; i < ex->op_array->last_var; i++) {
-                                                                               if (ex->op_array->vars[i].hash_value == hval &&
-                                                                                   ex->op_array->vars[i].name_len == offset->value.str.len &&
-                                                                                   !memcmp(ex->op_array->vars[i].name, offset->value.str.val, offset->value.str.len)) {
-                                                                                       ex->CVs[i] = NULL;
-                                                                                       break;
-                                                                               }
-                                                                       }
-                                                               }
-                                                       }
+                                               if (ht == &EG(symbol_table)) {
+                                                       zend_delete_global_variable_ex(offset->value.str.val, offset->value.str.len, hval TSRMLS_CC);
+                                               } else {
+                                                       zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval);
                                                }
                                                if (IS_CONST == IS_CV || IS_CONST == IS_VAR) {
                                                        zval_ptr_dtor(&offset);
@@ -18179,7 +19441,7 @@ num_index_dim:
                                break;
                        }
                        case IS_OBJECT:
-                               if (!Z_OBJ_HT_P(*container)->unset_dimension) {
+                               if (UNEXPECTED(Z_OBJ_HT_P(*container)->unset_dimension == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use object as array");
                                }
                                if (0) {
@@ -18203,15 +19465,20 @@ num_index_dim:
 
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       zval **container;
+       zval *offset;
 
-       zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
-       zval *offset = opline->op2.zv;
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       offset = opline->op2.zv;
 
        if (IS_UNUSED != IS_VAR || container) {
                if (IS_UNUSED == IS_CV && container != &EG(uninitialized_zval_ptr)) {
@@ -18238,19 +19505,23 @@ static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_UNUSED_CONST_HANDLER(ZEND_OPCODE_H
 
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_isset_isempty_dim_prop_obj_handler_SPEC_UNUSED_CONST(int prop_dim, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       zval **container;
        zval **value = NULL;
        int result = 0;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+
        if (IS_UNUSED != IS_VAR || container) {
 
                zval *offset = opline->op2.zv;
@@ -18344,7 +19615,7 @@ num_index_prop:
                        zval tmp;
 
                        if (Z_TYPE_P(offset) != IS_LONG) {
-                               tmp = *offset;
+                               ZVAL_COPY_VALUE(&tmp, offset);
                                zval_copy_ctor(&tmp);
                                convert_to_long(&tmp);
                                offset = &tmp;
@@ -18367,13 +19638,13 @@ num_index_prop:
        }
 
        Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
-
        if (opline->extended_value & ZEND_ISSET) {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = result;
-       } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+       } else {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = !result;
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -18389,33 +19660,31 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_CONST_HANDLER(
 
 static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op2, free_op_data1;
        zval **object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
        zval *object;
-       zval *property = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval *value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
+       zval *property = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       zval *value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
        znode_op *result = &opline->result;
        int have_get_ptr = 0;
 
-       if (IS_UNUSED == IS_VAR && !object_ptr) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
 
-       EX_T(result->var).var.ptr_ptr = NULL;
        make_real_object(object_ptr TSRMLS_CC);
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to assign property of non-object");
                zval_dtor(free_op2.var);
                FREE_OP(free_op_data1);
 
                if (RETURN_VALUE_USED(opline)) {
-                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                       EX_T(result->var).var.ptr_ptr = NULL;
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                }
        } else {
                /* here we are sure we are dealing with an object */
@@ -18433,9 +19702,9 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(int (*
                                have_get_ptr = 1;
                                binary_op(*zptr, *zptr, value TSRMLS_CC);
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = *zptr;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(*zptr);
+                                       EX_T(opline->result.var).var.ptr = *zptr;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -18472,17 +19741,17 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(int (*
                                        Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
                                }
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = z;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(z);
+                                       EX_T(opline->result.var).var.ptr = z;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                                zval_ptr_dtor(&z);
                        } else {
                                zend_error(E_WARNING, "Attempt to assign property of non-object");
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                                       EX_T(result->var).var.ptr_ptr = NULL;
-                                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                                       PZVAL_LOCK(&EG(uninitialized_zval));
+                                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -18496,17 +19765,19 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(int (*
        }
 
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2, free_op_data2, free_op_data1;
        zval **var_ptr;
        zval *value;
 
+       SAVE_OPLINE();
        switch (opline->extended_value) {
                case ZEND_ASSIGN_OBJ:
                        return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
@@ -18514,48 +19785,51 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_TMP(int (*bina
                case ZEND_ASSIGN_DIM: {
                                zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
 
-                               if (IS_UNUSED == IS_VAR && !container) {
+                               if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-                               } else if (Z_TYPE_PP(container) == IS_OBJECT) {
+                               } else if (UNEXPECTED(Z_TYPE_PP(container) == IS_OBJECT)) {
                                        if (IS_UNUSED == IS_VAR && !0) {
                                                Z_ADDREF_PP(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
                                        }
                                        return zend_binary_assign_op_obj_helper_SPEC_UNUSED_TMP(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                                } else {
-                                       zend_op *op_data = opline+1;
-                                       zval *dim = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+                                       zval *dim = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
-                                       zend_fetch_dimension_address(&EX_T(op_data->op2.var), container, dim, IS_TMP_VAR, BP_VAR_RW TSRMLS_CC);
-                                       value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-                                       var_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-                                       ZEND_VM_INC_OPCODE();
+                                       zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), container, dim, IS_TMP_VAR, BP_VAR_RW TSRMLS_CC);
+                                       value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+                                       var_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
                                }
                        }
                        break;
                default:
-                       value = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+                       value = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
                        var_ptr = NULL;
                        /* do nothing */
                        break;
        }
 
-       if (!var_ptr) {
+       if (UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
        }
 
-       if (*var_ptr == EG(error_zval_ptr)) {
+       if (UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
                zval_dtor(free_op2.var);
 
+               CHECK_EXCEPTION();
+               if (opline->extended_value == ZEND_ASSIGN_DIM) {
+                       ZEND_VM_INC_OPCODE();
+               }
                ZEND_VM_NEXT_OPCODE();
        }
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *objval = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -18568,16 +19842,21 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_TMP(int (*bina
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *var_ptr);
                PZVAL_LOCK(*var_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *var_ptr);
        }
        zval_dtor(free_op2.var);
 
        if (opline->extended_value == ZEND_ASSIGN_DIM) {
                FREE_OP(free_op_data1);
                FREE_OP_VAR_PTR(free_op_data2);
-       }
 
+               CHECK_EXCEPTION();
+               ZEND_VM_INC_OPCODE();
+       } else {
+
+               CHECK_EXCEPTION();
+       }
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -18638,29 +19917,35 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE
 
 static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_TMP(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
-       zval **object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       zval **object_ptr;
        zval *object;
-       zval *property = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **retval = &EX_T(opline->result.var).var.ptr;
+       zval *property;
+       zval **retval;
        int have_get_ptr = 0;
 
-       if (IS_UNUSED == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       property = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       retval = &EX_T(opline->result.var).var.ptr;
+
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                zval_dtor(free_op2.var);
                if (RETURN_VALUE_USED(opline)) {
-                       *retval = EG(uninitialized_zval_ptr);
-                       PZVAL_LOCK(*retval);
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       *retval = &EG(uninitialized_zval);
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -18688,7 +19973,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_TMP(incdec_
                if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -18708,8 +19993,8 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_TMP(incdec_
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                        if (RETURN_VALUE_USED(opline)) {
-                               *retval = EG(uninitialized_zval_ptr);
-                               PZVAL_LOCK(*retval);
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               *retval = &EG(uninitialized_zval);
                        }
                }
        }
@@ -18720,6 +20005,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_TMP(incdec_
                zval_dtor(free_op2.var);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -18735,26 +20021,32 @@ static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_H
 
 static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_TMP(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
-       zval **object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       zval **object_ptr;
        zval *object;
-       zval *property = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval *retval = &EX_T(opline->result.var).tmp_var;
+       zval *property;
+       zval *retval;
        int have_get_ptr = 0;
 
-       if (IS_UNUSED == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       property = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       retval = &EX_T(opline->result.var).tmp_var;
+
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                zval_dtor(free_op2.var);
-               *retval = *EG(uninitialized_zval_ptr);
+               ZVAL_NULL(retval);
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -18770,7 +20062,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_TMP(incdec
                        have_get_ptr = 1;
                        SEPARATE_ZVAL_IF_NOT_REF(zptr);
 
-                       *retval = **zptr;
+                       ZVAL_COPY_VALUE(retval, *zptr);
                        zendi_zval_copy_ctor(*retval);
 
                        incdec_op(*zptr);
@@ -18783,7 +20075,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_TMP(incdec
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
                        zval *z_copy;
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -18793,12 +20085,11 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_TMP(incdec
                                }
                                z = value;
                        }
-                       *retval = *z;
+                       ZVAL_COPY_VALUE(retval, z);
                        zendi_zval_copy_ctor(*retval);
                        ALLOC_ZVAL(z_copy);
-                       *z_copy = *z;
+                       INIT_PZVAL_COPY(z_copy, z);
                        zendi_zval_copy_ctor(*z_copy);
-                       INIT_PZVAL(z_copy);
                        incdec_op(z_copy);
                        Z_ADDREF_P(z);
                        Z_OBJ_HT_P(object)->write_property(object, property, z_copy, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
@@ -18806,7 +20097,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_TMP(incdec
                        zval_ptr_dtor(&z);
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-                       *retval = *EG(uninitialized_zval_ptr);
+                       ZVAL_NULL(retval);
                }
        }
 
@@ -18816,6 +20107,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_TMP(incdec
                zval_dtor(free_op2.var);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -18829,21 +20121,24 @@ static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_
        return zend_post_incdec_property_helper_SPEC_UNUSED_TMP(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_UNUSED_TMP(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_UNUSED_TMP(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *container = _get_obj_zval_ptr_unused(TSRMLS_C);
+       zval *container;
        zend_free_op free_op2;
-       zval *offset  = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval *offset;
 
-       if (Z_TYPE_P(container) != IS_OBJECT || !Z_OBJ_HT_P(container)->read_property) {
-               if (type != BP_VAR_IS) {
-                       zend_error(E_NOTICE, "Trying to get property of non-object");
-               }
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_unused(TSRMLS_C);
+       offset  = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               zend_error(E_NOTICE, "Trying to get property of non-object");
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
                zval_dtor(free_op2.var);
        } else {
@@ -18854,7 +20149,7 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_UNUSED_TMP
                }
 
                /* here we are sure we are dealing with an object */
-               retval = Z_OBJ_HT_P(container)->read_property(container, offset, type, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
                if (!RETURN_VALUE_USED(opline)) {
                        if (Z_REFCOUNT_P(retval) == 0) {
@@ -18863,8 +20158,8 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_UNUSED_TMP
                                FREE_ZVAL(retval);
                        }
                } else {
-                       AI_SET_PTR(EX_T(opline->result.var).var, retval);
                        PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                }
 
                if (1) {
@@ -18874,21 +20169,25 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_UNUSED_TMP
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_property_address_read_helper_SPEC_UNUSED_TMP(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_fetch_property_address_read_helper_SPEC_UNUSED_TMP(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *property = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval *property;
        zval **container;
 
+       SAVE_OPLINE();
+       property = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
        if (IS_UNUSED == IS_VAR && (opline->extended_value & ZEND_FETCH_ADD_LOCK)) {
                PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
                EX_T(opline->op1.var).var.ptr = *EX_T(opline->op1.var).var.ptr_ptr;
@@ -18898,45 +20197,48 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_H
                MAKE_REAL_ZVAL_PTR(property);
        }
        container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
-       if (IS_UNUSED == IS_VAR && !container) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
+
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
        if (1) {
                zval_ptr_dtor(&property);
        } else {
                zval_dtor(free_op2.var);
        }
-       if (IS_UNUSED == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_UNUSED == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
        /* We are going to assign the result by reference */
        if (opline->extended_value & ZEND_FETCH_MAKE_REF) {
-               Z_DELREF_PP(EX_T(opline->result.var).var.ptr_ptr);
-               SEPARATE_ZVAL_TO_MAKE_IS_REF(EX_T(opline->result.var).var.ptr_ptr);
-               Z_ADDREF_PP(EX_T(opline->result.var).var.ptr_ptr);
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+
+               Z_DELREF_PP(retval_ptr);
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
+               Z_ADDREF_PP(retval_ptr);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *property = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       zval *property;
+       zval **container;
+
+       SAVE_OPLINE();
+       property = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
 
        if (1) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       if (IS_UNUSED == IS_VAR && !container) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_RW TSRMLS_CC);
@@ -18945,37 +20247,83 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_
        } else {
                zval_dtor(free_op2.var);
        }
-       if (IS_UNUSED == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_UNUSED == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_property_address_read_helper_SPEC_UNUSED_TMP(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       USE_OPLINE
+
+       zval *container;
+       zend_free_op free_op2;
+       zval *offset;
+
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_unused(TSRMLS_C);
+       offset  = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               if (RETURN_VALUE_USED(opline)) {
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+               }
+               zval_dtor(free_op2.var);
+       } else {
+               zval *retval;
+
+               if (1) {
+                       MAKE_REAL_ZVAL_PTR(offset);
+               }
+
+               /* here we are sure we are dealing with an object */
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+
+               if (!RETURN_VALUE_USED(opline)) {
+                       if (Z_REFCOUNT_P(retval) == 0) {
+                               GC_REMOVE_ZVAL_FROM_BUFFER(retval);
+                               zval_dtor(retval);
+                               FREE_ZVAL(retval);
+                       }
+               } else {
+                       PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
+               }
+
+               if (1) {
+                       zval_ptr_dtor(&offset);
+               } else {
+                       zval_dtor(free_op2.var);
+               }
+       }
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        if (ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))) {
                /* Behave like FETCH_OBJ_W */
                zend_free_op free_op1, free_op2;
-               zval *property = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-               zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+               zval *property;
+               zval **container;
+
+               SAVE_OPLINE();
+               property = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+               container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
 
                if (1) {
                        MAKE_REAL_ZVAL_PTR(property);
                }
-               if (IS_UNUSED == IS_VAR && !container) {
+               if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
                }
                zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
@@ -18984,27 +20332,27 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_TMP_HANDLER(ZEND_O
                } else {
                        zval_dtor(free_op2.var);
                }
-               if (IS_UNUSED == IS_VAR && 0 &&
-                   READY_TO_DESTROY(free_op1.var)) {
-                       AI_USE_PTR(EX_T(opline->result.var).var);
-                       if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                           Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                               SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-                       }
+               if (IS_UNUSED == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+                       EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
-               return zend_fetch_property_address_read_helper_SPEC_UNUSED_TMP(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_fetch_property_address_read_helper_SPEC_UNUSED_TMP(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2, free_res;
-       zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
-       zval *property = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **container;
+       zval *property;
+
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       property = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
        if (IS_UNUSED == IS_CV) {
                if (container != &EG(uninitialized_zval_ptr)) {
@@ -19014,7 +20362,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCO
        if (1) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       if (IS_UNUSED == IS_VAR && !container) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_UNSET TSRMLS_CC);
@@ -19023,13 +20371,8 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCO
        } else {
                zval_dtor(free_op2.var);
        }
-       if (IS_UNUSED == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_UNUSED == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
        PZVAL_UNLOCK(*EX_T(opline->result.var).var.ptr_ptr, &free_res);
@@ -19038,24 +20381,28 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCO
        }
        PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
        FREE_OP_VAR_PTR(free_res);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op2;
-       zval **object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
-       zval *property_name = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **object_ptr;
+       zval *property_name;
+
+       SAVE_OPLINE();
+       object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       property_name = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
        if (1) {
                MAKE_REAL_ZVAL_PTR(property_name);
        }
-       if (IS_UNUSED == IS_VAR && !object_ptr) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, op_data->op1_type, &op_data->op1, EX(Ts), ZEND_ASSIGN_OBJ, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), ZEND_ASSIGN_OBJ, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
        if (1) {
                zval_ptr_dtor(&property_name);
        } else {
@@ -19063,19 +20410,23 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HA
        }
 
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_VAR_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval *str = &EX_T(opline->result.var).tmp_var;
-       zval *var = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval *var;
        zval var_copy;
        int use_copy = 0;
 
+       SAVE_OPLINE();
+       var = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
        if (IS_UNUSED == IS_UNUSED) {
                /* Initialize for erealloc in add_string_to_string */
                Z_STRVAL_P(str) = NULL;
@@ -19105,22 +20456,25 @@ static int ZEND_FASTCALL  ZEND_ADD_VAR_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDL
         */
        zval_dtor(free_op2.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        char *function_name_strval;
        int function_name_strlen;
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
-       function_name = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       function_name = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
-       if (Z_TYPE_P(function_name)!=IS_STRING) {
+       if (IS_TMP_VAR != IS_CONST &&
+           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                zend_error_noreturn(E_ERROR, "Method name must be a string");
        }
 
@@ -19129,14 +20483,15 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_TMP_HANDLER(ZEND_OPC
 
        EX(object) = _get_obj_zval_ptr_unused(TSRMLS_C);
 
-       if (EX(object) && Z_TYPE_P(EX(object)) == IS_OBJECT) {
-               if (Z_OBJ_HT_P(EX(object))->get_method == NULL) {
+       if (EXPECTED(EX(object) != NULL) &&
+           EXPECTED(Z_TYPE_P(EX(object)) == IS_OBJECT)) {
+               if (UNEXPECTED(Z_OBJ_HT_P(EX(object))->get_method == NULL)) {
                        zend_error_noreturn(E_ERROR, "Object does not support method calls");
                }
 
                /* First, locate the function. */
                EX(fbc) = Z_OBJ_HT_P(EX(object))->get_method(&EX(object), function_name_strval, function_name_strlen, ((IS_TMP_VAR == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
-               if (!EX(fbc)) {
+               if (UNEXPECTED(EX(fbc) == NULL)) {
                        zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", Z_OBJ_CLASS_NAME_P(EX(object)), function_name_strval);
                }
 
@@ -19161,12 +20516,13 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_TMP_HANDLER(ZEND_OPC
 
        zval_dtor(free_op2.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (IS_UNUSED == IS_UNUSED) {
@@ -19180,13 +20536,17 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HA
 
 static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
-       zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
-       zval *offset = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **container;
+       zval *offset;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       offset = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
        if (IS_UNUSED != IS_VAR || container) {
                if (IS_UNUSED == IS_CV && container != &EG(uninitialized_zval_ptr)) {
                        SEPARATE_ZVAL_IF_NOT_REF(container);
@@ -19220,24 +20580,10 @@ num_index_dim:
                                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                                        }
                                                }
-                                               if (zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval) == SUCCESS &&
-                                           ht == &EG(symbol_table)) {
-                                                       zend_execute_data *ex;
-
-                                                       for (ex = execute_data; ex; ex = ex->prev_execute_data) {
-                                                               if (ex->op_array && ex->symbol_table == ht) {
-                                                                       int i;
-
-                                                                       for (i = 0; i < ex->op_array->last_var; i++) {
-                                                                               if (ex->op_array->vars[i].hash_value == hval &&
-                                                                                   ex->op_array->vars[i].name_len == offset->value.str.len &&
-                                                                                   !memcmp(ex->op_array->vars[i].name, offset->value.str.val, offset->value.str.len)) {
-                                                                                       ex->CVs[i] = NULL;
-                                                                                       break;
-                                                                               }
-                                                                       }
-                                                               }
-                                                       }
+                                               if (ht == &EG(symbol_table)) {
+                                                       zend_delete_global_variable_ex(offset->value.str.val, offset->value.str.len, hval TSRMLS_CC);
+                                               } else {
+                                                       zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval);
                                                }
                                                if (IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) {
                                                        zval_ptr_dtor(&offset);
@@ -19254,7 +20600,7 @@ num_index_dim:
                                break;
                        }
                        case IS_OBJECT:
-                               if (!Z_OBJ_HT_P(*container)->unset_dimension) {
+                               if (UNEXPECTED(Z_OBJ_HT_P(*container)->unset_dimension == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use object as array");
                                }
                                if (1) {
@@ -19278,15 +20624,20 @@ num_index_dim:
                zval_dtor(free_op2.var);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
-       zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
-       zval *offset = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **container;
+       zval *offset;
+
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       offset = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
        if (IS_UNUSED != IS_VAR || container) {
                if (IS_UNUSED == IS_CV && container != &EG(uninitialized_zval_ptr)) {
@@ -19313,22 +20664,26 @@ static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_UNUSED_TMP_HANDLER(ZEND_OPCODE_HAN
                zval_dtor(free_op2.var);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_isset_isempty_dim_prop_obj_handler_SPEC_UNUSED_TMP(int prop_dim, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       zval **container;
        zval **value = NULL;
        int result = 0;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+
        if (IS_UNUSED != IS_VAR || container) {
                zend_free_op free_op2;
-               zval *offset = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+               zval *offset = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
                if (Z_TYPE_PP(container) == IS_ARRAY && !prop_dim) {
                        HashTable *ht;
@@ -19419,7 +20774,7 @@ num_index_prop:
                        zval tmp;
 
                        if (Z_TYPE_P(offset) != IS_LONG) {
-                               tmp = *offset;
+                               ZVAL_COPY_VALUE(&tmp, offset);
                                zval_copy_ctor(&tmp);
                                convert_to_long(&tmp);
                                offset = &tmp;
@@ -19442,13 +20797,13 @@ num_index_prop:
        }
 
        Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
-
        if (opline->extended_value & ZEND_ISSET) {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = result;
-       } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+       } else {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = !result;
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -19464,33 +20819,31 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_TMP_HANDLER(ZE
 
 static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op2, free_op_data1;
        zval **object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
        zval *object;
-       zval *property = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval *value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
+       zval *property = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       zval *value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
        znode_op *result = &opline->result;
        int have_get_ptr = 0;
 
-       if (IS_UNUSED == IS_VAR && !object_ptr) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
 
-       EX_T(result->var).var.ptr_ptr = NULL;
        make_real_object(object_ptr TSRMLS_CC);
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to assign property of non-object");
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
                FREE_OP(free_op_data1);
 
                if (RETURN_VALUE_USED(opline)) {
-                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                       EX_T(result->var).var.ptr_ptr = NULL;
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                }
        } else {
                /* here we are sure we are dealing with an object */
@@ -19508,9 +20861,9 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(int (*
                                have_get_ptr = 1;
                                binary_op(*zptr, *zptr, value TSRMLS_CC);
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = *zptr;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(*zptr);
+                                       EX_T(opline->result.var).var.ptr = *zptr;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -19547,17 +20900,17 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(int (*
                                        Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
                                }
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = z;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(z);
+                                       EX_T(opline->result.var).var.ptr = z;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                                zval_ptr_dtor(&z);
                        } else {
                                zend_error(E_WARNING, "Attempt to assign property of non-object");
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                                       EX_T(result->var).var.ptr_ptr = NULL;
-                                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                                       PZVAL_LOCK(&EG(uninitialized_zval));
+                                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -19571,17 +20924,19 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(int (*
        }
 
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2, free_op_data2, free_op_data1;
        zval **var_ptr;
        zval *value;
 
+       SAVE_OPLINE();
        switch (opline->extended_value) {
                case ZEND_ASSIGN_OBJ:
                        return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
@@ -19589,48 +20944,51 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_VAR(int (*bina
                case ZEND_ASSIGN_DIM: {
                                zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
 
-                               if (IS_UNUSED == IS_VAR && !container) {
+                               if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-                               } else if (Z_TYPE_PP(container) == IS_OBJECT) {
+                               } else if (UNEXPECTED(Z_TYPE_PP(container) == IS_OBJECT)) {
                                        if (IS_UNUSED == IS_VAR && !0) {
                                                Z_ADDREF_PP(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
                                        }
                                        return zend_binary_assign_op_obj_helper_SPEC_UNUSED_VAR(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                                } else {
-                                       zend_op *op_data = opline+1;
-                                       zval *dim = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+                                       zval *dim = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
-                                       zend_fetch_dimension_address(&EX_T(op_data->op2.var), container, dim, IS_VAR, BP_VAR_RW TSRMLS_CC);
-                                       value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-                                       var_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-                                       ZEND_VM_INC_OPCODE();
+                                       zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), container, dim, IS_VAR, BP_VAR_RW TSRMLS_CC);
+                                       value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+                                       var_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
                                }
                        }
                        break;
                default:
-                       value = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+                       value = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
                        var_ptr = NULL;
                        /* do nothing */
                        break;
        }
 
-       if (!var_ptr) {
+       if (UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
        }
 
-       if (*var_ptr == EG(error_zval_ptr)) {
+       if (UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
 
+               CHECK_EXCEPTION();
+               if (opline->extended_value == ZEND_ASSIGN_DIM) {
+                       ZEND_VM_INC_OPCODE();
+               }
                ZEND_VM_NEXT_OPCODE();
        }
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *objval = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -19643,16 +21001,21 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_VAR(int (*bina
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *var_ptr);
                PZVAL_LOCK(*var_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *var_ptr);
        }
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
 
        if (opline->extended_value == ZEND_ASSIGN_DIM) {
                FREE_OP(free_op_data1);
                FREE_OP_VAR_PTR(free_op_data2);
-       }
 
+               CHECK_EXCEPTION();
+               ZEND_VM_INC_OPCODE();
+       } else {
+
+               CHECK_EXCEPTION();
+       }
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -19713,29 +21076,35 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE
 
 static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_VAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
-       zval **object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       zval **object_ptr;
        zval *object;
-       zval *property = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **retval = &EX_T(opline->result.var).var.ptr;
+       zval *property;
+       zval **retval;
        int have_get_ptr = 0;
 
-       if (IS_UNUSED == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       property = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       retval = &EX_T(opline->result.var).var.ptr;
+
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
                if (RETURN_VALUE_USED(opline)) {
-                       *retval = EG(uninitialized_zval_ptr);
-                       PZVAL_LOCK(*retval);
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       *retval = &EG(uninitialized_zval);
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -19763,7 +21132,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_VAR(incdec_
                if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -19783,8 +21152,8 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_VAR(incdec_
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                        if (RETURN_VALUE_USED(opline)) {
-                               *retval = EG(uninitialized_zval_ptr);
-                               PZVAL_LOCK(*retval);
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               *retval = &EG(uninitialized_zval);
                        }
                }
        }
@@ -19795,6 +21164,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_VAR(incdec_
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -19810,26 +21180,32 @@ static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_H
 
 static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_VAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
-       zval **object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       zval **object_ptr;
        zval *object;
-       zval *property = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval *retval = &EX_T(opline->result.var).tmp_var;
+       zval *property;
+       zval *retval;
        int have_get_ptr = 0;
 
-       if (IS_UNUSED == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       property = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       retval = &EX_T(opline->result.var).tmp_var;
+
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
-               *retval = *EG(uninitialized_zval_ptr);
+               ZVAL_NULL(retval);
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -19845,7 +21221,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_VAR(incdec
                        have_get_ptr = 1;
                        SEPARATE_ZVAL_IF_NOT_REF(zptr);
 
-                       *retval = **zptr;
+                       ZVAL_COPY_VALUE(retval, *zptr);
                        zendi_zval_copy_ctor(*retval);
 
                        incdec_op(*zptr);
@@ -19858,7 +21234,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_VAR(incdec
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
                        zval *z_copy;
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -19868,12 +21244,11 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_VAR(incdec
                                }
                                z = value;
                        }
-                       *retval = *z;
+                       ZVAL_COPY_VALUE(retval, z);
                        zendi_zval_copy_ctor(*retval);
                        ALLOC_ZVAL(z_copy);
-                       *z_copy = *z;
+                       INIT_PZVAL_COPY(z_copy, z);
                        zendi_zval_copy_ctor(*z_copy);
-                       INIT_PZVAL(z_copy);
                        incdec_op(z_copy);
                        Z_ADDREF_P(z);
                        Z_OBJ_HT_P(object)->write_property(object, property, z_copy, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
@@ -19881,7 +21256,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_VAR(incdec
                        zval_ptr_dtor(&z);
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-                       *retval = *EG(uninitialized_zval_ptr);
+                       ZVAL_NULL(retval);
                }
        }
 
@@ -19891,6 +21266,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_VAR(incdec
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -19904,21 +21280,24 @@ static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_
        return zend_post_incdec_property_helper_SPEC_UNUSED_VAR(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_UNUSED_VAR(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_UNUSED_VAR(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *container = _get_obj_zval_ptr_unused(TSRMLS_C);
+       zval *container;
        zend_free_op free_op2;
-       zval *offset  = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval *offset;
 
-       if (Z_TYPE_P(container) != IS_OBJECT || !Z_OBJ_HT_P(container)->read_property) {
-               if (type != BP_VAR_IS) {
-                       zend_error(E_NOTICE, "Trying to get property of non-object");
-               }
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_unused(TSRMLS_C);
+       offset  = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               zend_error(E_NOTICE, "Trying to get property of non-object");
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        } else {
@@ -19929,7 +21308,7 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_UNUSED_VAR
                }
 
                /* here we are sure we are dealing with an object */
-               retval = Z_OBJ_HT_P(container)->read_property(container, offset, type, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
                if (!RETURN_VALUE_USED(opline)) {
                        if (Z_REFCOUNT_P(retval) == 0) {
@@ -19938,8 +21317,8 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_UNUSED_VAR
                                FREE_ZVAL(retval);
                        }
                } else {
-                       AI_SET_PTR(EX_T(opline->result.var).var, retval);
                        PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                }
 
                if (0) {
@@ -19949,21 +21328,25 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_UNUSED_VAR
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_property_address_read_helper_SPEC_UNUSED_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_fetch_property_address_read_helper_SPEC_UNUSED_VAR(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *property = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval *property;
        zval **container;
 
+       SAVE_OPLINE();
+       property = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
        if (IS_UNUSED == IS_VAR && (opline->extended_value & ZEND_FETCH_ADD_LOCK)) {
                PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
                EX_T(opline->op1.var).var.ptr = *EX_T(opline->op1.var).var.ptr_ptr;
@@ -19973,45 +21356,48 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_H
                MAKE_REAL_ZVAL_PTR(property);
        }
        container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
-       if (IS_UNUSED == IS_VAR && !container) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
+
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
        if (0) {
                zval_ptr_dtor(&property);
        } else {
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        }
-       if (IS_UNUSED == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_UNUSED == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
        /* We are going to assign the result by reference */
        if (opline->extended_value & ZEND_FETCH_MAKE_REF) {
-               Z_DELREF_PP(EX_T(opline->result.var).var.ptr_ptr);
-               SEPARATE_ZVAL_TO_MAKE_IS_REF(EX_T(opline->result.var).var.ptr_ptr);
-               Z_ADDREF_PP(EX_T(opline->result.var).var.ptr_ptr);
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+
+               Z_DELREF_PP(retval_ptr);
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
+               Z_ADDREF_PP(retval_ptr);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *property = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       zval *property;
+       zval **container;
+
+       SAVE_OPLINE();
+       property = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
 
        if (0) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       if (IS_UNUSED == IS_VAR && !container) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_RW TSRMLS_CC);
@@ -20020,37 +21406,83 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_
        } else {
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        }
-       if (IS_UNUSED == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_UNUSED == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_property_address_read_helper_SPEC_UNUSED_VAR(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       USE_OPLINE
+
+       zval *container;
+       zend_free_op free_op2;
+       zval *offset;
+
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_unused(TSRMLS_C);
+       offset  = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               if (RETURN_VALUE_USED(opline)) {
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+               }
+               if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       } else {
+               zval *retval;
+
+               if (0) {
+                       MAKE_REAL_ZVAL_PTR(offset);
+               }
+
+               /* here we are sure we are dealing with an object */
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+
+               if (!RETURN_VALUE_USED(opline)) {
+                       if (Z_REFCOUNT_P(retval) == 0) {
+                               GC_REMOVE_ZVAL_FROM_BUFFER(retval);
+                               zval_dtor(retval);
+                               FREE_ZVAL(retval);
+                       }
+               } else {
+                       PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
+               }
+
+               if (0) {
+                       zval_ptr_dtor(&offset);
+               } else {
+                       if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+               }
+       }
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        if (ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))) {
                /* Behave like FETCH_OBJ_W */
                zend_free_op free_op1, free_op2;
-               zval *property = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-               zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+               zval *property;
+               zval **container;
+
+               SAVE_OPLINE();
+               property = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+               container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
 
                if (0) {
                        MAKE_REAL_ZVAL_PTR(property);
                }
-               if (IS_UNUSED == IS_VAR && !container) {
+               if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
                }
                zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
@@ -20059,27 +21491,27 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_VAR_HANDLER(ZEND_O
                } else {
                        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
                }
-               if (IS_UNUSED == IS_VAR && 0 &&
-                   READY_TO_DESTROY(free_op1.var)) {
-                       AI_USE_PTR(EX_T(opline->result.var).var);
-                       if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                           Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                               SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-                       }
+               if (IS_UNUSED == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+                       EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
-               return zend_fetch_property_address_read_helper_SPEC_UNUSED_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_fetch_property_address_read_helper_SPEC_UNUSED_VAR(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2, free_res;
-       zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
-       zval *property = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **container;
+       zval *property;
+
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       property = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
        if (IS_UNUSED == IS_CV) {
                if (container != &EG(uninitialized_zval_ptr)) {
@@ -20089,7 +21521,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCO
        if (0) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       if (IS_UNUSED == IS_VAR && !container) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_UNSET TSRMLS_CC);
@@ -20098,13 +21530,8 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCO
        } else {
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        }
-       if (IS_UNUSED == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_UNUSED == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
        PZVAL_UNLOCK(*EX_T(opline->result.var).var.ptr_ptr, &free_res);
@@ -20113,24 +21540,28 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCO
        }
        PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
        FREE_OP_VAR_PTR(free_res);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op2;
-       zval **object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
-       zval *property_name = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **object_ptr;
+       zval *property_name;
+
+       SAVE_OPLINE();
+       object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       property_name = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
        if (0) {
                MAKE_REAL_ZVAL_PTR(property_name);
        }
-       if (IS_UNUSED == IS_VAR && !object_ptr) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, op_data->op1_type, &op_data->op1, EX(Ts), ZEND_ASSIGN_OBJ, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), ZEND_ASSIGN_OBJ, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
        if (0) {
                zval_ptr_dtor(&property_name);
        } else {
@@ -20138,19 +21569,23 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HA
        }
 
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_VAR_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval *str = &EX_T(opline->result.var).tmp_var;
-       zval *var = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval *var;
        zval var_copy;
        int use_copy = 0;
 
+       SAVE_OPLINE();
+       var = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
        if (IS_UNUSED == IS_UNUSED) {
                /* Initialize for erealloc in add_string_to_string */
                Z_STRVAL_P(str) = NULL;
@@ -20180,22 +21615,25 @@ static int ZEND_FASTCALL  ZEND_ADD_VAR_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDL
         */
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        char *function_name_strval;
        int function_name_strlen;
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
-       function_name = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       function_name = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
-       if (Z_TYPE_P(function_name)!=IS_STRING) {
+       if (IS_VAR != IS_CONST &&
+           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                zend_error_noreturn(E_ERROR, "Method name must be a string");
        }
 
@@ -20204,14 +21642,15 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_VAR_HANDLER(ZEND_OPC
 
        EX(object) = _get_obj_zval_ptr_unused(TSRMLS_C);
 
-       if (EX(object) && Z_TYPE_P(EX(object)) == IS_OBJECT) {
-               if (Z_OBJ_HT_P(EX(object))->get_method == NULL) {
+       if (EXPECTED(EX(object) != NULL) &&
+           EXPECTED(Z_TYPE_P(EX(object)) == IS_OBJECT)) {
+               if (UNEXPECTED(Z_OBJ_HT_P(EX(object))->get_method == NULL)) {
                        zend_error_noreturn(E_ERROR, "Object does not support method calls");
                }
 
                /* First, locate the function. */
                EX(fbc) = Z_OBJ_HT_P(EX(object))->get_method(&EX(object), function_name_strval, function_name_strlen, ((IS_VAR == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
-               if (!EX(fbc)) {
+               if (UNEXPECTED(EX(fbc) == NULL)) {
                        zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", Z_OBJ_CLASS_NAME_P(EX(object)), function_name_strval);
                }
 
@@ -20236,12 +21675,13 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_VAR_HANDLER(ZEND_OPC
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (IS_UNUSED == IS_UNUSED) {
@@ -20255,13 +21695,17 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HA
 
 static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
-       zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
-       zval *offset = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **container;
+       zval *offset;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       offset = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
        if (IS_UNUSED != IS_VAR || container) {
                if (IS_UNUSED == IS_CV && container != &EG(uninitialized_zval_ptr)) {
                        SEPARATE_ZVAL_IF_NOT_REF(container);
@@ -20295,24 +21739,10 @@ num_index_dim:
                                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                                        }
                                                }
-                                               if (zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval) == SUCCESS &&
-                                           ht == &EG(symbol_table)) {
-                                                       zend_execute_data *ex;
-
-                                                       for (ex = execute_data; ex; ex = ex->prev_execute_data) {
-                                                               if (ex->op_array && ex->symbol_table == ht) {
-                                                                       int i;
-
-                                                                       for (i = 0; i < ex->op_array->last_var; i++) {
-                                                                               if (ex->op_array->vars[i].hash_value == hval &&
-                                                                                   ex->op_array->vars[i].name_len == offset->value.str.len &&
-                                                                                   !memcmp(ex->op_array->vars[i].name, offset->value.str.val, offset->value.str.len)) {
-                                                                                       ex->CVs[i] = NULL;
-                                                                                       break;
-                                                                               }
-                                                                       }
-                                                               }
-                                                       }
+                                               if (ht == &EG(symbol_table)) {
+                                                       zend_delete_global_variable_ex(offset->value.str.val, offset->value.str.len, hval TSRMLS_CC);
+                                               } else {
+                                                       zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval);
                                                }
                                                if (IS_VAR == IS_CV || IS_VAR == IS_VAR) {
                                                        zval_ptr_dtor(&offset);
@@ -20329,7 +21759,7 @@ num_index_dim:
                                break;
                        }
                        case IS_OBJECT:
-                               if (!Z_OBJ_HT_P(*container)->unset_dimension) {
+                               if (UNEXPECTED(Z_OBJ_HT_P(*container)->unset_dimension == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use object as array");
                                }
                                if (0) {
@@ -20353,15 +21783,20 @@ num_index_dim:
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
-       zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
-       zval *offset = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **container;
+       zval *offset;
+
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       offset = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
        if (IS_UNUSED != IS_VAR || container) {
                if (IS_UNUSED == IS_CV && container != &EG(uninitialized_zval_ptr)) {
@@ -20388,22 +21823,26 @@ static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_UNUSED_VAR_HANDLER(ZEND_OPCODE_HAN
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_isset_isempty_dim_prop_obj_handler_SPEC_UNUSED_VAR(int prop_dim, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       zval **container;
        zval **value = NULL;
        int result = 0;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+
        if (IS_UNUSED != IS_VAR || container) {
                zend_free_op free_op2;
-               zval *offset = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+               zval *offset = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
                if (Z_TYPE_PP(container) == IS_ARRAY && !prop_dim) {
                        HashTable *ht;
@@ -20494,7 +21933,7 @@ num_index_prop:
                        zval tmp;
 
                        if (Z_TYPE_P(offset) != IS_LONG) {
-                               tmp = *offset;
+                               ZVAL_COPY_VALUE(&tmp, offset);
                                zval_copy_ctor(&tmp);
                                convert_to_long(&tmp);
                                offset = &tmp;
@@ -20517,13 +21956,13 @@ num_index_prop:
        }
 
        Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
-
        if (opline->extended_value & ZEND_ISSET) {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = result;
-       } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+       } else {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = !result;
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -20539,33 +21978,31 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_VAR_HANDLER(ZE
 
 static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_UNUSED(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op_data1;
        zval **object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
        zval *object;
        zval *property = NULL;
-       zval *value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
+       zval *value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
        znode_op *result = &opline->result;
        int have_get_ptr = 0;
 
-       if (IS_UNUSED == IS_VAR && !object_ptr) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
 
-       EX_T(result->var).var.ptr_ptr = NULL;
        make_real_object(object_ptr TSRMLS_CC);
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to assign property of non-object");
 
                FREE_OP(free_op_data1);
 
                if (RETURN_VALUE_USED(opline)) {
-                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                       EX_T(result->var).var.ptr_ptr = NULL;
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                }
        } else {
                /* here we are sure we are dealing with an object */
@@ -20583,9 +22020,9 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_UNUSED(int
                                have_get_ptr = 1;
                                binary_op(*zptr, *zptr, value TSRMLS_CC);
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = *zptr;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(*zptr);
+                                       EX_T(opline->result.var).var.ptr = *zptr;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -20622,17 +22059,17 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_UNUSED(int
                                        Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
                                }
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = z;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(z);
+                                       EX_T(opline->result.var).var.ptr = z;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                                zval_ptr_dtor(&z);
                        } else {
                                zend_error(E_WARNING, "Attempt to assign property of non-object");
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                                       EX_T(result->var).var.ptr_ptr = NULL;
-                                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                                       PZVAL_LOCK(&EG(uninitialized_zval));
+                                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -20646,17 +22083,19 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_UNUSED(int
        }
 
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_UNUSED(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op_data2, free_op_data1;
        zval **var_ptr;
        zval *value;
 
+       SAVE_OPLINE();
        switch (opline->extended_value) {
                case ZEND_ASSIGN_OBJ:
                        return zend_binary_assign_op_obj_helper_SPEC_UNUSED_UNUSED(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
@@ -20664,21 +22103,19 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_UNUSED(int (*b
                case ZEND_ASSIGN_DIM: {
                                zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
 
-                               if (IS_UNUSED == IS_VAR && !container) {
+                               if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-                               } else if (Z_TYPE_PP(container) == IS_OBJECT) {
+                               } else if (UNEXPECTED(Z_TYPE_PP(container) == IS_OBJECT)) {
                                        if (IS_UNUSED == IS_VAR && !0) {
                                                Z_ADDREF_PP(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
                                        }
                                        return zend_binary_assign_op_obj_helper_SPEC_UNUSED_UNUSED(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                                } else {
-                                       zend_op *op_data = opline+1;
                                        zval *dim = NULL;
 
-                                       zend_fetch_dimension_address(&EX_T(op_data->op2.var), container, dim, IS_UNUSED, BP_VAR_RW TSRMLS_CC);
-                                       value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-                                       var_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-                                       ZEND_VM_INC_OPCODE();
+                                       zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), container, dim, IS_UNUSED, BP_VAR_RW TSRMLS_CC);
+                                       value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+                                       var_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
                                }
                        }
                        break;
@@ -20689,23 +22126,28 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_UNUSED(int (*b
                        break;
        }
 
-       if (!var_ptr) {
+       if (UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
        }
 
-       if (*var_ptr == EG(error_zval_ptr)) {
+       if (UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
 
 
+               CHECK_EXCEPTION();
+               if (opline->extended_value == ZEND_ASSIGN_DIM) {
+                       ZEND_VM_INC_OPCODE();
+               }
                ZEND_VM_NEXT_OPCODE();
        }
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *objval = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -20718,15 +22160,20 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_UNUSED(int (*b
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *var_ptr);
                PZVAL_LOCK(*var_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *var_ptr);
        }
 
        if (opline->extended_value == ZEND_ASSIGN_DIM) {
                FREE_OP(free_op_data1);
                FREE_OP_VAR_PTR(free_op_data2);
-       }
 
+               CHECK_EXCEPTION();
+               ZEND_VM_INC_OPCODE();
+       } else {
+
+               CHECK_EXCEPTION();
+       }
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -20787,7 +22234,7 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_UNUSED_UNUSED_HANDLER(ZEND_OPC
 
 static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_UNUSED_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (IS_UNUSED == IS_UNUSED) {
@@ -20801,33 +22248,31 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_UNUSED_UNUSED_HANDLER(ZEND_OPCODE
 
 static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_CV(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op_data1;
        zval **object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
        zval *object;
-       zval *property = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-       zval *value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
+       zval *property = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+       zval *value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
        znode_op *result = &opline->result;
        int have_get_ptr = 0;
 
-       if (IS_UNUSED == IS_VAR && !object_ptr) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
 
-       EX_T(result->var).var.ptr_ptr = NULL;
        make_real_object(object_ptr TSRMLS_CC);
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to assign property of non-object");
 
                FREE_OP(free_op_data1);
 
                if (RETURN_VALUE_USED(opline)) {
-                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                       EX_T(result->var).var.ptr_ptr = NULL;
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                }
        } else {
                /* here we are sure we are dealing with an object */
@@ -20845,9 +22290,9 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_CV(int (*b
                                have_get_ptr = 1;
                                binary_op(*zptr, *zptr, value TSRMLS_CC);
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = *zptr;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(*zptr);
+                                       EX_T(opline->result.var).var.ptr = *zptr;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -20884,17 +22329,17 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_CV(int (*b
                                        Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
                                }
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = z;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(z);
+                                       EX_T(opline->result.var).var.ptr = z;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                                zval_ptr_dtor(&z);
                        } else {
                                zend_error(E_WARNING, "Attempt to assign property of non-object");
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                                       EX_T(result->var).var.ptr_ptr = NULL;
-                                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                                       PZVAL_LOCK(&EG(uninitialized_zval));
+                                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -20908,17 +22353,19 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_UNUSED_CV(int (*b
        }
 
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_CV(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op_data2, free_op_data1;
        zval **var_ptr;
        zval *value;
 
+       SAVE_OPLINE();
        switch (opline->extended_value) {
                case ZEND_ASSIGN_OBJ:
                        return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CV(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
@@ -20926,48 +22373,51 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_CV(int (*binar
                case ZEND_ASSIGN_DIM: {
                                zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
 
-                               if (IS_UNUSED == IS_VAR && !container) {
+                               if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-                               } else if (Z_TYPE_PP(container) == IS_OBJECT) {
+                               } else if (UNEXPECTED(Z_TYPE_PP(container) == IS_OBJECT)) {
                                        if (IS_UNUSED == IS_VAR && !0) {
                                                Z_ADDREF_PP(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
                                        }
                                        return zend_binary_assign_op_obj_helper_SPEC_UNUSED_CV(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                                } else {
-                                       zend_op *op_data = opline+1;
-                                       zval *dim = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+                                       zval *dim = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
 
-                                       zend_fetch_dimension_address(&EX_T(op_data->op2.var), container, dim, IS_CV, BP_VAR_RW TSRMLS_CC);
-                                       value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-                                       var_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-                                       ZEND_VM_INC_OPCODE();
+                                       zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), container, dim, IS_CV, BP_VAR_RW TSRMLS_CC);
+                                       value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+                                       var_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
                                }
                        }
                        break;
                default:
-                       value = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+                       value = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
                        var_ptr = NULL;
                        /* do nothing */
                        break;
        }
 
-       if (!var_ptr) {
+       if (UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
        }
 
-       if (*var_ptr == EG(error_zval_ptr)) {
+       if (UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
 
 
+               CHECK_EXCEPTION();
+               if (opline->extended_value == ZEND_ASSIGN_DIM) {
+                       ZEND_VM_INC_OPCODE();
+               }
                ZEND_VM_NEXT_OPCODE();
        }
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *objval = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -20980,15 +22430,20 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_UNUSED_CV(int (*binar
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *var_ptr);
                PZVAL_LOCK(*var_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *var_ptr);
        }
 
        if (opline->extended_value == ZEND_ASSIGN_DIM) {
                FREE_OP(free_op_data1);
                FREE_OP_VAR_PTR(free_op_data2);
-       }
 
+               CHECK_EXCEPTION();
+               ZEND_VM_INC_OPCODE();
+       } else {
+
+               CHECK_EXCEPTION();
+       }
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -21049,29 +22504,35 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_
 
 static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_CV(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval **object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       zval **object_ptr;
        zval *object;
-       zval *property = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-       zval **retval = &EX_T(opline->result.var).var.ptr;
+       zval *property;
+       zval **retval;
        int have_get_ptr = 0;
 
-       if (IS_UNUSED == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       property = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+       retval = &EX_T(opline->result.var).var.ptr;
+
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
 
                if (RETURN_VALUE_USED(opline)) {
-                       *retval = EG(uninitialized_zval_ptr);
-                       PZVAL_LOCK(*retval);
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       *retval = &EG(uninitialized_zval);
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -21099,7 +22560,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_CV(incdec_t
                if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -21119,8 +22580,8 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_CV(incdec_t
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                        if (RETURN_VALUE_USED(opline)) {
-                               *retval = EG(uninitialized_zval_ptr);
-                               PZVAL_LOCK(*retval);
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               *retval = &EG(uninitialized_zval);
                        }
                }
        }
@@ -21131,6 +22592,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_UNUSED_CV(incdec_t
 
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -21146,26 +22608,32 @@ static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HA
 
 static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_CV(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval **object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       zval **object_ptr;
        zval *object;
-       zval *property = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-       zval *retval = &EX_T(opline->result.var).tmp_var;
+       zval *property;
+       zval *retval;
        int have_get_ptr = 0;
 
-       if (IS_UNUSED == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       property = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+       retval = &EX_T(opline->result.var).tmp_var;
+
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
 
-               *retval = *EG(uninitialized_zval_ptr);
+               ZVAL_NULL(retval);
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -21181,7 +22649,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_CV(incdec_
                        have_get_ptr = 1;
                        SEPARATE_ZVAL_IF_NOT_REF(zptr);
 
-                       *retval = **zptr;
+                       ZVAL_COPY_VALUE(retval, *zptr);
                        zendi_zval_copy_ctor(*retval);
 
                        incdec_op(*zptr);
@@ -21194,7 +22662,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_CV(incdec_
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
                        zval *z_copy;
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -21204,12 +22672,11 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_CV(incdec_
                                }
                                z = value;
                        }
-                       *retval = *z;
+                       ZVAL_COPY_VALUE(retval, z);
                        zendi_zval_copy_ctor(*retval);
                        ALLOC_ZVAL(z_copy);
-                       *z_copy = *z;
+                       INIT_PZVAL_COPY(z_copy, z);
                        zendi_zval_copy_ctor(*z_copy);
-                       INIT_PZVAL(z_copy);
                        incdec_op(z_copy);
                        Z_ADDREF_P(z);
                        Z_OBJ_HT_P(object)->write_property(object, property, z_copy, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
@@ -21217,7 +22684,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_CV(incdec_
                        zval_ptr_dtor(&z);
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-                       *retval = *EG(uninitialized_zval_ptr);
+                       ZVAL_NULL(retval);
                }
        }
 
@@ -21227,6 +22694,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_UNUSED_CV(incdec_
 
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -21240,21 +22708,24 @@ static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_H
        return zend_post_incdec_property_helper_SPEC_UNUSED_CV(decrement_function, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
-static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_UNUSED_CV(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_UNUSED_CV(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *container = _get_obj_zval_ptr_unused(TSRMLS_C);
+       zval *container;
 
-       zval *offset  = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       zval *offset;
 
-       if (Z_TYPE_P(container) != IS_OBJECT || !Z_OBJ_HT_P(container)->read_property) {
-               if (type != BP_VAR_IS) {
-                       zend_error(E_NOTICE, "Trying to get property of non-object");
-               }
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_unused(TSRMLS_C);
+       offset  = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               zend_error(E_NOTICE, "Trying to get property of non-object");
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
 
        } else {
@@ -21265,7 +22736,7 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_UNUSED_CV(
                }
 
                /* here we are sure we are dealing with an object */
-               retval = Z_OBJ_HT_P(container)->read_property(container, offset, type, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
                if (!RETURN_VALUE_USED(opline)) {
                        if (Z_REFCOUNT_P(retval) == 0) {
@@ -21274,8 +22745,8 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_UNUSED_CV(
                                FREE_ZVAL(retval);
                        }
                } else {
-                       AI_SET_PTR(EX_T(opline->result.var).var, retval);
                        PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                }
 
                if (0) {
@@ -21285,21 +22756,25 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_UNUSED_CV(
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_property_address_read_helper_SPEC_UNUSED_CV(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_fetch_property_address_read_helper_SPEC_UNUSED_CV(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *property = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       zval *property;
        zval **container;
 
+       SAVE_OPLINE();
+       property = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+
        if (IS_UNUSED == IS_VAR && (opline->extended_value & ZEND_FETCH_ADD_LOCK)) {
                PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
                EX_T(opline->op1.var).var.ptr = *EX_T(opline->op1.var).var.ptr_ptr;
@@ -21309,45 +22784,48 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HA
                MAKE_REAL_ZVAL_PTR(property);
        }
        container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
-       if (IS_UNUSED == IS_VAR && !container) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
+
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
        if (0) {
                zval_ptr_dtor(&property);
        } else {
 
        }
-       if (IS_UNUSED == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_UNUSED == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
        /* We are going to assign the result by reference */
        if (opline->extended_value & ZEND_FETCH_MAKE_REF) {
-               Z_DELREF_PP(EX_T(opline->result.var).var.ptr_ptr);
-               SEPARATE_ZVAL_TO_MAKE_IS_REF(EX_T(opline->result.var).var.ptr_ptr);
-               Z_ADDREF_PP(EX_T(opline->result.var).var.ptr_ptr);
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+
+               Z_DELREF_PP(retval_ptr);
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
+               Z_ADDREF_PP(retval_ptr);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *property = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-       zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       zval *property;
+       zval **container;
+
+       SAVE_OPLINE();
+       property = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+       container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
 
        if (0) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       if (IS_UNUSED == IS_VAR && !container) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_RW TSRMLS_CC);
@@ -21356,37 +22834,83 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_H
        } else {
 
        }
-       if (IS_UNUSED == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_UNUSED == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_property_address_read_helper_SPEC_UNUSED_CV(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       USE_OPLINE
+
+       zval *container;
+
+       zval *offset;
+
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_unused(TSRMLS_C);
+       offset  = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               if (RETURN_VALUE_USED(opline)) {
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+               }
+
+       } else {
+               zval *retval;
+
+               if (0) {
+                       MAKE_REAL_ZVAL_PTR(offset);
+               }
+
+               /* here we are sure we are dealing with an object */
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+
+               if (!RETURN_VALUE_USED(opline)) {
+                       if (Z_REFCOUNT_P(retval) == 0) {
+                               GC_REMOVE_ZVAL_FROM_BUFFER(retval);
+                               zval_dtor(retval);
+                               FREE_ZVAL(retval);
+                       }
+               } else {
+                       PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
+               }
+
+               if (0) {
+                       zval_ptr_dtor(&offset);
+               } else {
+
+               }
+       }
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        if (ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))) {
                /* Behave like FETCH_OBJ_W */
                zend_free_op free_op1;
-               zval *property = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-               zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+               zval *property;
+               zval **container;
+
+               SAVE_OPLINE();
+               property = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+               container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
 
                if (0) {
                        MAKE_REAL_ZVAL_PTR(property);
                }
-               if (IS_UNUSED == IS_VAR && !container) {
+               if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
                }
                zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
@@ -21395,27 +22919,27 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_UNUSED_CV_HANDLER(ZEND_OP
                } else {
 
                }
-               if (IS_UNUSED == IS_VAR && 0 &&
-                   READY_TO_DESTROY(free_op1.var)) {
-                       AI_USE_PTR(EX_T(opline->result.var).var);
-                       if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                           Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                               SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-                       }
+               if (IS_UNUSED == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+                       EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
-               return zend_fetch_property_address_read_helper_SPEC_UNUSED_CV(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_fetch_property_address_read_helper_SPEC_UNUSED_CV(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_res;
-       zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
-       zval *property = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       zval **container;
+       zval *property;
+
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       property = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
 
        if (IS_UNUSED == IS_CV) {
                if (container != &EG(uninitialized_zval_ptr)) {
@@ -21425,7 +22949,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_CV_HANDLER(ZEND_OPCOD
        if (0) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       if (IS_UNUSED == IS_VAR && !container) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_UNSET TSRMLS_CC);
@@ -21434,13 +22958,8 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_CV_HANDLER(ZEND_OPCOD
        } else {
 
        }
-       if (IS_UNUSED == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_UNUSED == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
        PZVAL_UNLOCK(*EX_T(opline->result.var).var.ptr_ptr, &free_res);
@@ -21449,24 +22968,28 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_UNUSED_CV_HANDLER(ZEND_OPCOD
        }
        PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
        FREE_OP_VAR_PTR(free_res);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
 
-       zval **object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
-       zval *property_name = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       zval **object_ptr;
+       zval *property_name;
+
+       SAVE_OPLINE();
+       object_ptr = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       property_name = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
 
        if (0) {
                MAKE_REAL_ZVAL_PTR(property_name);
        }
-       if (IS_UNUSED == IS_VAR && !object_ptr) {
+       if (IS_UNUSED == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, op_data->op1_type, &op_data->op1, EX(Ts), ZEND_ASSIGN_OBJ, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), ZEND_ASSIGN_OBJ, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
        if (0) {
                zval_ptr_dtor(&property_name);
        } else {
@@ -21474,19 +22997,23 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HAN
        }
 
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_VAR_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *str = &EX_T(opline->result.var).tmp_var;
-       zval *var = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       zval *var;
        zval var_copy;
        int use_copy = 0;
 
+       SAVE_OPLINE();
+       var = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+
        if (IS_UNUSED == IS_UNUSED) {
                /* Initialize for erealloc in add_string_to_string */
                Z_STRVAL_P(str) = NULL;
@@ -21515,22 +23042,25 @@ static int ZEND_FASTCALL  ZEND_ADD_VAR_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLE
         * string offsets or overloaded objects
         */
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        char *function_name_strval;
        int function_name_strlen;
 
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
-       function_name = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       function_name = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
 
-       if (Z_TYPE_P(function_name)!=IS_STRING) {
+       if (IS_CV != IS_CONST &&
+           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                zend_error_noreturn(E_ERROR, "Method name must be a string");
        }
 
@@ -21539,14 +23069,15 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_CV_HANDLER(ZEND_OPCO
 
        EX(object) = _get_obj_zval_ptr_unused(TSRMLS_C);
 
-       if (EX(object) && Z_TYPE_P(EX(object)) == IS_OBJECT) {
-               if (Z_OBJ_HT_P(EX(object))->get_method == NULL) {
+       if (EXPECTED(EX(object) != NULL) &&
+           EXPECTED(Z_TYPE_P(EX(object)) == IS_OBJECT)) {
+               if (UNEXPECTED(Z_OBJ_HT_P(EX(object))->get_method == NULL)) {
                        zend_error_noreturn(E_ERROR, "Object does not support method calls");
                }
 
                /* First, locate the function. */
                EX(fbc) = Z_OBJ_HT_P(EX(object))->get_method(&EX(object), function_name_strval, function_name_strlen, ((IS_CV == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
-               if (!EX(fbc)) {
+               if (UNEXPECTED(EX(fbc) == NULL)) {
                        zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", Z_OBJ_CLASS_NAME_P(EX(object)), function_name_strval);
                }
 
@@ -21570,12 +23101,13 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_UNUSED_CV_HANDLER(ZEND_OPCO
        }
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (IS_UNUSED == IS_UNUSED) {
@@ -21589,13 +23121,17 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HAN
 
 static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
-       zval *offset = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       zval **container;
+       zval *offset;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       offset = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+
        if (IS_UNUSED != IS_VAR || container) {
                if (IS_UNUSED == IS_CV && container != &EG(uninitialized_zval_ptr)) {
                        SEPARATE_ZVAL_IF_NOT_REF(container);
@@ -21629,24 +23165,10 @@ num_index_dim:
                                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                                        }
                                                }
-                                               if (zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval) == SUCCESS &&
-                                           ht == &EG(symbol_table)) {
-                                                       zend_execute_data *ex;
-
-                                                       for (ex = execute_data; ex; ex = ex->prev_execute_data) {
-                                                               if (ex->op_array && ex->symbol_table == ht) {
-                                                                       int i;
-
-                                                                       for (i = 0; i < ex->op_array->last_var; i++) {
-                                                                               if (ex->op_array->vars[i].hash_value == hval &&
-                                                                                   ex->op_array->vars[i].name_len == offset->value.str.len &&
-                                                                                   !memcmp(ex->op_array->vars[i].name, offset->value.str.val, offset->value.str.len)) {
-                                                                                       ex->CVs[i] = NULL;
-                                                                                       break;
-                                                                               }
-                                                                       }
-                                                               }
-                                                       }
+                                               if (ht == &EG(symbol_table)) {
+                                                       zend_delete_global_variable_ex(offset->value.str.val, offset->value.str.len, hval TSRMLS_CC);
+                                               } else {
+                                                       zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval);
                                                }
                                                if (IS_CV == IS_CV || IS_CV == IS_VAR) {
                                                        zval_ptr_dtor(&offset);
@@ -21663,7 +23185,7 @@ num_index_dim:
                                break;
                        }
                        case IS_OBJECT:
-                               if (!Z_OBJ_HT_P(*container)->unset_dimension) {
+                               if (UNEXPECTED(Z_OBJ_HT_P(*container)->unset_dimension == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use object as array");
                                }
                                if (0) {
@@ -21687,15 +23209,20 @@ num_index_dim:
 
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       zval **container;
+       zval *offset;
 
-       zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
-       zval *offset = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       offset = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
 
        if (IS_UNUSED != IS_VAR || container) {
                if (IS_UNUSED == IS_CV && container != &EG(uninitialized_zval_ptr)) {
@@ -21722,22 +23249,26 @@ static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_UNUSED_CV_HANDLER(ZEND_OPCODE_HAND
 
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_isset_isempty_dim_prop_obj_handler_SPEC_UNUSED_CV(int prop_dim, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval **container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+       zval **container;
        zval **value = NULL;
        int result = 0;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = _get_obj_zval_ptr_ptr_unused(TSRMLS_C);
+
        if (IS_UNUSED != IS_VAR || container) {
 
-               zval *offset = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+               zval *offset = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
 
                if (Z_TYPE_PP(container) == IS_ARRAY && !prop_dim) {
                        HashTable *ht;
@@ -21828,7 +23359,7 @@ num_index_prop:
                        zval tmp;
 
                        if (Z_TYPE_P(offset) != IS_LONG) {
-                               tmp = *offset;
+                               ZVAL_COPY_VALUE(&tmp, offset);
                                zval_copy_ctor(&tmp);
                                convert_to_long(&tmp);
                                offset = &tmp;
@@ -21851,13 +23382,13 @@ num_index_prop:
        }
 
        Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
-
        if (opline->extended_value & ZEND_ISSET) {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = result;
-       } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+       } else {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = !result;
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -21873,47 +23404,56 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_UNUSED_CV_HANDLER(ZEN
 
 static int ZEND_FASTCALL  ZEND_BW_NOT_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        bitwise_not_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC) TSRMLS_CC);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BOOL_NOT_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        boolean_not_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC) TSRMLS_CC);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_PRE_INC_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       zval **var_ptr;
 
-       zval **var_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_RW TSRMLS_CC);
+       SAVE_OPLINE();
+       var_ptr = _get_zval_ptr_ptr_cv_BP_VAR_RW(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && !var_ptr) {
+       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
-       if (IS_CV == IS_VAR && *var_ptr == EG(error_zval_ptr)) {
+       if (IS_CV == IS_VAR && UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *val = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -21926,34 +23466,40 @@ static int ZEND_FASTCALL  ZEND_PRE_INC_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *var_ptr);
                PZVAL_LOCK(*var_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *var_ptr);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_PRE_DEC_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       zval **var_ptr;
 
-       zval **var_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_RW TSRMLS_CC);
+       SAVE_OPLINE();
+       var_ptr = _get_zval_ptr_ptr_cv_BP_VAR_RW(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && !var_ptr) {
+       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
-       if (IS_CV == IS_VAR && *var_ptr == EG(error_zval_ptr)) {
+       if (IS_CV == IS_VAR && UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *val = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -21966,36 +23512,43 @@ static int ZEND_FASTCALL  ZEND_PRE_DEC_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *var_ptr);
                PZVAL_LOCK(*var_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *var_ptr);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_POST_INC_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       zval **var_ptr, *retval;
 
-       zval **var_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_RW TSRMLS_CC);
+       SAVE_OPLINE();
+       var_ptr = _get_zval_ptr_ptr_cv_BP_VAR_RW(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && !var_ptr) {
+       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
-       if (IS_CV == IS_VAR && *var_ptr == EG(error_zval_ptr)) {
+       if (IS_CV == IS_VAR && UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       EX_T(opline->result.var).tmp_var = *EG(uninitialized_zval_ptr);
+                       ZVAL_NULL(&EX_T(opline->result.var).tmp_var);
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
-       EX_T(opline->result.var).tmp_var = **var_ptr;
-       zendi_zval_copy_ctor(EX_T(opline->result.var).tmp_var);
+       retval = &EX_T(opline->result.var).tmp_var;
+       ZVAL_COPY_VALUE(retval, *var_ptr);
+       zendi_zval_copy_ctor(*retval);
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *val = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -22007,32 +23560,39 @@ static int ZEND_FASTCALL  ZEND_POST_INC_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS
                increment_function(*var_ptr);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_POST_DEC_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval **var_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_RW TSRMLS_CC);
+       zval **var_ptr, *retval;
 
-       if (IS_CV == IS_VAR && !var_ptr) {
+       SAVE_OPLINE();
+       var_ptr = _get_zval_ptr_ptr_cv_BP_VAR_RW(EX_CVs(), opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_VAR && UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
-       if (IS_CV == IS_VAR && *var_ptr == EG(error_zval_ptr)) {
+       if (IS_CV == IS_VAR && UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       EX_T(opline->result.var).tmp_var = *EG(uninitialized_zval_ptr);
+                       ZVAL_NULL(&EX_T(opline->result.var).tmp_var);
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
-       EX_T(opline->result.var).tmp_var = **var_ptr;
-       zendi_zval_copy_ctor(EX_T(opline->result.var).tmp_var);
+       retval = &EX_T(opline->result.var).tmp_var;
+       ZVAL_COPY_VALUE(retval, *var_ptr);
+       zendi_zval_copy_ctor(*retval);
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *val = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -22044,18 +23604,23 @@ static int ZEND_FASTCALL  ZEND_POST_DEC_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS
                decrement_function(*var_ptr);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ECHO_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval z_copy;
-       zval *z = _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+       zval *z;
+
+       SAVE_OPLINE();
+       z = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
 
        if (IS_CV != IS_CONST &&
-           Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get_method != NULL &&
+           UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) &&
+           Z_OBJ_HT_P(z)->get_method != NULL &&
                zend_std_cast_object_tostring(z, &z_copy, IS_STRING TSRMLS_CC) == SUCCESS) {
                zend_print_variable(&z_copy);
                zval_dtor(&z_copy);
@@ -22063,31 +23628,33 @@ static int ZEND_FASTCALL  ZEND_ECHO_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
                zend_print_variable(z);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_PRINT_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-
-       Z_LVAL(EX_T(opline->result.var).tmp_var) = 1;
-       Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_LONG;
+       USE_OPLINE
 
+       ZVAL_LONG(&EX_T(opline->result.var).tmp_var, 1);
        return ZEND_ECHO_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
 static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CV(int type, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *varname = _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+       zval *varname;
        zval **retval;
        zval tmp_varname;
        HashTable *target_symbol_table;
        ulong hash_value;
 
-       if (IS_CV != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-               tmp_varname = *varname;
+       SAVE_OPLINE();
+       varname = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+
+       if (IS_CV != IS_CONST && UNEXPECTED(Z_TYPE_P(varname) != IS_STRING)) {
+               ZVAL_COPY_VALUE(&tmp_varname, varname);
                zval_copy_ctor(&tmp_varname);
                convert_to_string(&tmp_varname);
                varname = &tmp_varname;
@@ -22100,6 +23667,7 @@ static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CV(int type, ZEND_OP
                target_symbol_table = zend_get_target_symbol_table(opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
 /*
                if (!target_symbol_table) {
+                       CHECK_EXCEPTION();
                        ZEND_VM_NEXT_OPCODE();
                }
 */
@@ -22123,12 +23691,9 @@ static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CV(int type, ZEND_OP
                                case BP_VAR_RW:
                                        zend_error(E_NOTICE,"Undefined variable: %s", Z_STRVAL_P(varname));
                                        /* break missing intentionally */
-                               case BP_VAR_W: {
-                                               zval *new_zval = &EG(uninitialized_zval);
-
-                                               Z_ADDREF_P(new_zval);
-                                               zend_hash_quick_update(target_symbol_table, Z_STRVAL_P(varname), Z_STRLEN_P(varname)+1, hash_value, &new_zval, sizeof(zval *), (void **) &retval);
-                                       }
+                               case BP_VAR_W:
+                                       Z_ADDREF_P(&EG(uninitialized_zval));
+                                       zend_hash_quick_update(target_symbol_table, Z_STRVAL_P(varname), Z_STRLEN_P(varname)+1, hash_value, &EG(uninitialized_zval_ptr), sizeof(zval *), (void **) &retval);
                                        break;
                                EMPTY_SWITCH_DEFAULT_CASE()
                        }
@@ -22155,7 +23720,7 @@ static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CV(int type, ZEND_OP
 
 
        if (IS_CV != IS_CONST && varname == &tmp_varname) {
-               zval_dtor(varname);
+               zval_dtor(&tmp_varname);
        }
        if (RETURN_VALUE_USED(opline)) {
                if (opline->extended_value & ZEND_FETCH_MAKE_REF) {
@@ -22165,25 +23730,25 @@ static int ZEND_FASTCALL zend_fetch_var_address_helper_SPEC_CV(int type, ZEND_OP
                switch (type) {
                        case BP_VAR_R:
                        case BP_VAR_IS:
-                               AI_SET_PTR(EX_T(opline->result.var).var, *retval);
+                               AI_SET_PTR(&EX_T(opline->result.var), *retval);
                                break;
                        case BP_VAR_UNSET: {
                                zend_free_op free_res;
 
-                               EX_T(opline->result.var).var.ptr_ptr = retval;
-                               PZVAL_UNLOCK(*EX_T(opline->result.var).var.ptr_ptr, &free_res);
-                               if (EX_T(opline->result.var).var.ptr_ptr != &EG(uninitialized_zval_ptr)) {
-                                       SEPARATE_ZVAL_IF_NOT_REF(EX_T(opline->result.var).var.ptr_ptr);
+                               PZVAL_UNLOCK(*retval, &free_res);
+                               if (retval != &EG(uninitialized_zval_ptr)) {
+                                       SEPARATE_ZVAL_IF_NOT_REF(retval);
                                }
-                               PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
+                               PZVAL_LOCK(*retval);
                                FREE_OP_VAR_PTR(free_res);
-                               break;
+                       }
+                       /* break missing intentionally */
                        default:
                                EX_T(opline->result.var).var.ptr_ptr = retval;
                                break;
-                       }
                }
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -22204,7 +23769,9 @@ static int ZEND_FASTCALL  ZEND_FETCH_RW_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS
 
 static int ZEND_FASTCALL  ZEND_FETCH_FUNC_ARG_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_var_address_helper_SPEC_CV(ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (EX(opline)->extended_value & ZEND_FETCH_ARG_MASK))?BP_VAR_W:BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       USE_OPLINE
+
+       return zend_fetch_var_address_helper_SPEC_CV(ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))?BP_VAR_W:BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_UNSET_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
@@ -22219,18 +23786,21 @@ static int ZEND_FASTCALL  ZEND_FETCH_IS_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS
 
 static int ZEND_FASTCALL  ZEND_JMPZ_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *val = _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+       zval *val;
        int ret;
 
-       if (IS_CV == IS_TMP_VAR && Z_TYPE_P(val) == IS_BOOL) {
+       SAVE_OPLINE();
+       val = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_TMP_VAR && EXPECTED(Z_TYPE_P(val) == IS_BOOL)) {
                ret = Z_LVAL_P(val);
        } else {
                ret = i_zend_is_true(val);
 
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       ZEND_VM_CONTINUE();
+                       HANDLE_EXCEPTION();
                }
        }
        if (!ret) {
@@ -22246,18 +23816,21 @@ static int ZEND_FASTCALL  ZEND_JMPZ_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 
 static int ZEND_FASTCALL  ZEND_JMPNZ_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *val = _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+       zval *val;
        int ret;
 
-       if (IS_CV == IS_TMP_VAR && Z_TYPE_P(val) == IS_BOOL) {
+       SAVE_OPLINE();
+       val = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_TMP_VAR && EXPECTED(Z_TYPE_P(val) == IS_BOOL)) {
                ret = Z_LVAL_P(val);
        } else {
                ret = i_zend_is_true(val);
 
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       ZEND_VM_CONTINUE();
+                       HANDLE_EXCEPTION();
                }
        }
        if (ret) {
@@ -22273,18 +23846,21 @@ static int ZEND_FASTCALL  ZEND_JMPNZ_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 
 static int ZEND_FASTCALL  ZEND_JMPZNZ_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *val = _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+       zval *val;
        int retval;
 
-       if (IS_CV == IS_TMP_VAR && Z_TYPE_P(val) == IS_BOOL) {
+       SAVE_OPLINE();
+       val = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_TMP_VAR && EXPECTED(Z_TYPE_P(val) == IS_BOOL)) {
                retval = Z_LVAL_P(val);
        } else {
                retval = i_zend_is_true(val);
 
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       ZEND_VM_CONTINUE();
+                       HANDLE_EXCEPTION();
                }
        }
        if (EXPECTED(retval != 0)) {
@@ -22304,18 +23880,21 @@ static int ZEND_FASTCALL  ZEND_JMPZNZ_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 
 static int ZEND_FASTCALL  ZEND_JMPZ_EX_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *val = _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+       zval *val;
        int retval;
 
-       if (IS_CV == IS_TMP_VAR && Z_TYPE_P(val) == IS_BOOL) {
+       SAVE_OPLINE();
+       val = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_TMP_VAR && EXPECTED(Z_TYPE_P(val) == IS_BOOL)) {
                retval = Z_LVAL_P(val);
        } else {
                retval = i_zend_is_true(val);
 
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       ZEND_VM_CONTINUE();
+                       HANDLE_EXCEPTION();
                }
        }
        Z_LVAL(EX_T(opline->result.var).tmp_var) = retval;
@@ -22332,18 +23911,21 @@ static int ZEND_FASTCALL  ZEND_JMPZ_EX_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 
 static int ZEND_FASTCALL  ZEND_JMPNZ_EX_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *val = _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+       zval *val;
        int retval;
 
-       if (IS_CV == IS_TMP_VAR && Z_TYPE_P(val) == IS_BOOL) {
+       SAVE_OPLINE();
+       val = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_TMP_VAR && EXPECTED(Z_TYPE_P(val) == IS_BOOL)) {
                retval = Z_LVAL_P(val);
        } else {
                retval = i_zend_is_true(val);
 
                if (UNEXPECTED(EG(exception) != NULL)) {
-                       ZEND_VM_CONTINUE();
+                       HANDLE_EXCEPTION();
                }
        }
        Z_LVAL(EX_T(opline->result.var).tmp_var) = retval;
@@ -22360,12 +23942,13 @@ static int ZEND_FASTCALL  ZEND_JMPNZ_EX_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS
 
 static int ZEND_FASTCALL  ZEND_RETURN_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *retval_ptr;
        zval **retval_ptr_ptr;
 
 
-       if (EG(active_op_array)->return_reference == ZEND_RETURN_REF) {
+       SAVE_OPLINE();
+       if (UNEXPECTED(EG(active_op_array)->return_reference == ZEND_RETURN_REF)) {
 
                if (IS_CV == IS_CONST || IS_CV == IS_TMP_VAR) {
                        /* Not supposed to happen, but we'll allow it */
@@ -22373,9 +23956,9 @@ static int ZEND_FASTCALL  ZEND_RETURN_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
                        goto return_by_value;
                }
 
-               retval_ptr_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+               retval_ptr_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-               if (IS_CV == IS_VAR && !retval_ptr_ptr) {
+               if (IS_CV == IS_VAR && UNEXPECTED(retval_ptr_ptr == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot return string offsets by reference");
                }
 
@@ -22397,10 +23980,12 @@ static int ZEND_FASTCALL  ZEND_RETURN_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 
                        (*EG(return_value_ptr_ptr)) = (*retval_ptr_ptr);
                }
+
+               return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else {
 return_by_value:
 
-               retval_ptr = _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+               retval_ptr = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
 
                if (!EG(return_value_ptr_ptr)) {
                        if (IS_CV == IS_TMP_VAR) {
@@ -22427,21 +24012,22 @@ return_by_value:
                        INIT_PZVAL_COPY(ret, retval_ptr);
                        *EG(return_value_ptr_ptr) = ret;
                }
-       }
 
-       return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_leave_helper_SPEC(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
 }
 
 static int ZEND_FASTCALL  ZEND_THROW_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *value;
        zval *exception;
 
 
-       value = _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+       SAVE_OPLINE();
+       value = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_CONST || Z_TYPE_P(value) != IS_OBJECT) {
+       if (IS_CV == IS_CONST || UNEXPECTED(Z_TYPE_P(value) != IS_OBJECT)) {
                zend_error_noreturn(E_ERROR, "Can only throw objects");
        }
        zend_exception_save(TSRMLS_C);
@@ -22455,12 +24041,14 @@ static int ZEND_FASTCALL  ZEND_THROW_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
        zend_throw_exception_object(exception TSRMLS_CC);
        zend_exception_restore(TSRMLS_C);
 
-       ZEND_VM_NEXT_OPCODE();
+       HANDLE_EXCEPTION();
 }
 
 static int ZEND_FASTCALL  ZEND_SEND_VAL_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       SAVE_OPLINE();
        if (opline->extended_value==ZEND_DO_FCALL_BY_NAME
                && ARG_MUST_BE_SENT_BY_REF(EX(fbc), opline->op2.opline_num)) {
                        zend_error_noreturn(E_ERROR, "Cannot pass parameter %d by reference", opline->op2.opline_num);
@@ -22470,7 +24058,7 @@ static int ZEND_FASTCALL  ZEND_SEND_VAL_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS
                zval *value;
 
 
-               value = _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+               value = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
 
                ALLOC_ZVAL(valptr);
                INIT_PZVAL_COPY(valptr, value);
@@ -22480,15 +24068,16 @@ static int ZEND_FASTCALL  ZEND_SEND_VAL_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS
                zend_vm_stack_push(valptr TSRMLS_CC);
 
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_send_by_var_helper_SPEC_CV(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *varptr;
 
-       varptr = _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+       varptr = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
 
        if (varptr == &EG(uninitialized_zval)) {
                ALLOC_ZVAL(varptr);
@@ -22498,7 +24087,7 @@ static int ZEND_FASTCALL zend_send_by_var_helper_SPEC_CV(ZEND_OPCODE_HANDLER_ARG
                zval *original_var = varptr;
 
                ALLOC_ZVAL(varptr);
-               *varptr = *original_var;
+               ZVAL_COPY_VALUE(varptr, original_var);
                Z_UNSET_ISREF_P(varptr);
                Z_SET_REFCOUNT_P(varptr, 0);
                zval_copy_ctor(varptr);
@@ -22507,15 +24096,17 @@ static int ZEND_FASTCALL zend_send_by_var_helper_SPEC_CV(ZEND_OPCODE_HANDLER_ARG
        zend_vm_stack_push(varptr TSRMLS_CC);
        ;  /* for string offsets */
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SEND_VAR_NO_REF_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
        zval *varptr;
 
+       SAVE_OPLINE();
        if (opline->extended_value & ZEND_ARG_COMPILE_TIME_BOUND) { /* Had function_ptr at compile_time */
                if (!(opline->extended_value & ZEND_ARG_SEND_BY_REF)) {
                        return zend_send_by_var_helper_SPEC_CV(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
@@ -22531,7 +24122,7 @@ static int ZEND_FASTCALL  ZEND_SEND_VAR_NO_REF_SPEC_CV_HANDLER(ZEND_OPCODE_HANDL
                varptr = EX_T(opline->op1.var).var.ptr;
                PZVAL_UNLOCK_EX(varptr, &free_op1, 0);
        } else {
-               varptr = _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+               varptr = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
        }
        if ((!(opline->extended_value & ZEND_ARG_SEND_FUNCTION) ||
             EX_T(opline->op1.var).var.fcall_returned_reference) &&
@@ -22557,75 +24148,85 @@ static int ZEND_FASTCALL  ZEND_SEND_VAR_NO_REF_SPEC_CV_HANDLER(ZEND_OPCODE_HANDL
                zend_vm_stack_push(valptr TSRMLS_CC);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SEND_REF_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval **varptr_ptr;
        zval *varptr;
-       varptr_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && !varptr_ptr) {
+       SAVE_OPLINE();
+       varptr_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_VAR && UNEXPECTED(varptr_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Only variables can be passed by reference");
        }
 
-       if (EX(function_state).function->type == ZEND_INTERNAL_FUNCTION && !ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), opline->op2.opline_num)) {
-               return zend_send_by_var_helper_SPEC_CV(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-        }
+       if (EX(function_state).function->type == ZEND_INTERNAL_FUNCTION && !ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), opline->op2.opline_num)) {
+               return zend_send_by_var_helper_SPEC_CV(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       }
 
        SEPARATE_ZVAL_TO_MAKE_IS_REF(varptr_ptr);
        varptr = *varptr_ptr;
        Z_ADDREF_P(varptr);
        zend_vm_stack_push(varptr TSRMLS_CC);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SEND_VAR_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        if ((opline->extended_value == ZEND_DO_FCALL_BY_NAME)
                && ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), opline->op2.opline_num)) {
                return ZEND_SEND_REF_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
+       SAVE_OPLINE();
        return zend_send_by_var_helper_SPEC_CV(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
 static int ZEND_FASTCALL  ZEND_BOOL_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
+       zval *retval = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        /* PHP 3.0 returned "" for false and 1 for true, here we use 0 and 1 for now */
-       Z_LVAL(EX_T(opline->result.var).tmp_var) = i_zend_is_true(_get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC));
-       Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
+       ZVAL_BOOL(retval, i_zend_is_true(_get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC)));
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CLONE_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *obj = _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+       zval *obj;
        zend_class_entry *ce;
        zend_function *clone;
        zend_object_clone_obj_t clone_call;
 
+       SAVE_OPLINE();
+       obj = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+
        if (IS_CV == IS_CONST ||
-           (IS_CV == IS_VAR && !obj) ||
-           Z_TYPE_P(obj) != IS_OBJECT) {
+           (IS_CV == IS_VAR && UNEXPECTED(obj == NULL)) ||
+           UNEXPECTED(Z_TYPE_P(obj) != IS_OBJECT)) {
                zend_error_noreturn(E_ERROR, "__clone method called on non-object");
        }
 
        ce = Z_OBJCE_P(obj);
        clone = ce ? ce->clone : NULL;
        clone_call =  Z_OBJ_HT_P(obj)->clone_obj;
-       if (!clone_call) {
+       if (UNEXPECTED(clone_call == NULL)) {
                if (ce) {
                        zend_error_noreturn(E_ERROR, "Trying to clone an uncloneable object of class %s", ce->name);
                } else {
@@ -22637,42 +24238,49 @@ static int ZEND_FASTCALL  ZEND_CLONE_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
                if (clone->op_array.fn_flags & ZEND_ACC_PRIVATE) {
                        /* Ensure that if we're calling a private function, we're allowed to do so.
                         */
-                       if (ce != EG(scope)) {
+                       if (UNEXPECTED(ce != EG(scope))) {
                                zend_error_noreturn(E_ERROR, "Call to private %s::__clone() from context '%s'", ce->name, EG(scope) ? EG(scope)->name : "");
                        }
                } else if ((clone->common.fn_flags & ZEND_ACC_PROTECTED)) {
                        /* Ensure that if we're calling a protected function, we're allowed to do so.
                         */
-                       if (!zend_check_protected(clone->common.scope, EG(scope))) {
+                       if (UNEXPECTED(!zend_check_protected(clone->common.scope, EG(scope)))) {
                                zend_error_noreturn(E_ERROR, "Call to protected %s::__clone() from context '%s'", ce->name, EG(scope) ? EG(scope)->name : "");
                        }
                }
        }
 
-       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-       if (!EG(exception)) {
-               ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-               Z_OBJVAL_P(EX_T(opline->result.var).var.ptr) = clone_call(obj TSRMLS_CC);
-               Z_TYPE_P(EX_T(opline->result.var).var.ptr) = IS_OBJECT;
-               Z_SET_REFCOUNT_P(EX_T(opline->result.var).var.ptr, 1);
-               Z_SET_ISREF_P(EX_T(opline->result.var).var.ptr);
-               if (!RETURN_VALUE_USED(opline) || EG(exception)) {
-                       zval_ptr_dtor(&EX_T(opline->result.var).var.ptr);
+       if (EXPECTED(EG(exception) == NULL)) {
+               zval *retval;
+
+               ALLOC_ZVAL(retval);
+               Z_OBJVAL_P(retval) = clone_call(obj TSRMLS_CC);
+               Z_TYPE_P(retval) = IS_OBJECT;
+               Z_SET_REFCOUNT_P(retval, 1);
+               Z_SET_ISREF_P(retval);
+               if (!RETURN_VALUE_USED(opline) || UNEXPECTED(EG(exception) != NULL)) {
+                       zval_ptr_dtor(&retval);
+               } else {
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CAST_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *expr = _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+       zval *expr;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
+       expr = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+
        if (opline->extended_value != IS_STRING) {
-               *result = *expr;
+               ZVAL_COPY_VALUE(result, expr);
                if (!0) {
                        zendi_zval_copy_ctor(*result);
                }
@@ -22696,12 +24304,12 @@ static int ZEND_FASTCALL  ZEND_CAST_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 
                        zend_make_printable_zval(expr, &var_copy, &use_copy);
                        if (use_copy) {
-                               *result = var_copy;
+                               ZVAL_COPY_VALUE(result, &var_copy);
                                if (0) {
 
                                }
                        } else {
-                               *result = *expr;
+                               ZVAL_COPY_VALUE(result, expr);
                                if (!0) {
                                        zendi_zval_copy_ctor(*result);
                                }
@@ -22716,28 +24324,29 @@ static int ZEND_FASTCALL  ZEND_CAST_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
                        break;
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INCLUDE_OR_EVAL_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_op_array *new_op_array=NULL;
-       int return_value_used;
 
-       zval *inc_filename = _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+       zval *inc_filename;
        zval tmp_inc_filename;
        zend_bool failure_retval=0;
 
+       SAVE_OPLINE();
+       inc_filename = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+
        if (inc_filename->type!=IS_STRING) {
-               tmp_inc_filename = *inc_filename;
+               ZVAL_COPY_VALUE(&tmp_inc_filename, inc_filename);
                zval_copy_ctor(&tmp_inc_filename);
                convert_to_string(&tmp_inc_filename);
                inc_filename = &tmp_inc_filename;
        }
 
-       return_value_used = RETURN_VALUE_USED(opline);
-
        switch (opline->extended_value) {
                case ZEND_INCLUDE_ONCE:
                case ZEND_REQUIRE_ONCE: {
@@ -22795,12 +24404,18 @@ static int ZEND_FASTCALL  ZEND_INCLUDE_OR_EVAL_SPEC_CV_HANDLER(ZEND_OPCODE_HANDL
                zval_dtor(&tmp_inc_filename);
        }
 
-       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-       if (new_op_array && !EG(exception)) {
+       if (UNEXPECTED(EG(exception) != NULL)) {
+               HANDLE_EXCEPTION();
+       } else if (EXPECTED(new_op_array != NULL)) {
                EX(original_return_value) = EG(return_value_ptr_ptr);
-               EG(return_value_ptr_ptr) = return_value_used ? EX_T(opline->result.var).var.ptr_ptr : NULL;
                EG(active_op_array) = new_op_array;
-               EX_T(opline->result.var).var.ptr = NULL;
+               if (RETURN_VALUE_USED(opline)) {
+                       EX_T(opline->result.var).var.ptr = NULL;
+                       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
+                       EG(return_value_ptr_ptr) = EX_T(opline->result.var).var.ptr_ptr;
+               } else {
+                       EG(return_value_ptr_ptr) = NULL;
+               }
 
                EX(current_object) = EX(object);
 
@@ -22811,8 +24426,7 @@ static int ZEND_FASTCALL  ZEND_INCLUDE_OR_EVAL_SPEC_CV_HANDLER(ZEND_OPCODE_HANDL
                        zend_rebuild_symbol_table(TSRMLS_C);
                }
 
-               if (zend_execute == execute) {
-                       EX(call_opline) = opline;
+               if (EXPECTED(zend_execute == execute)) {
                        ZEND_VM_ENTER();
                } else {
                        zend_execute(new_op_array TSRMLS_CC);
@@ -22821,75 +24435,62 @@ static int ZEND_FASTCALL  ZEND_INCLUDE_OR_EVAL_SPEC_CV_HANDLER(ZEND_OPCODE_HANDL
                EX(function_state).function = (zend_function *) EX(op_array);
                EX(object) = EX(current_object);
 
-               if (return_value_used) {
-                       if (!EX_T(opline->result.var).var.ptr) { /* there was no return statement */
-                               ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                               INIT_PZVAL(EX_T(opline->result.var).var.ptr);
-                               Z_LVAL_P(EX_T(opline->result.var).var.ptr) = 1;
-                               Z_TYPE_P(EX_T(opline->result.var).var.ptr) = IS_BOOL;
-                       }
-               }
-
                EG(opline_ptr) = &EX(opline);
                EG(active_op_array) = EX(op_array);
                EG(return_value_ptr_ptr) = EX(original_return_value);
                destroy_op_array(new_op_array TSRMLS_CC);
                efree(new_op_array);
-               if (EG(exception)) {
+               if (UNEXPECTED(EG(exception) != NULL)) {
                        zend_throw_exception_internal(NULL TSRMLS_CC);
+                       HANDLE_EXCEPTION();
+               } else if (RETURN_VALUE_USED(opline)) {
+                       if (!EX_T(opline->result.var).var.ptr) { /* there was no return statement */
+                               zval *retval;
+
+                               ALLOC_ZVAL(retval);
+                               ZVAL_BOOL(retval, 1);
+                               INIT_PZVAL(retval);
+                               EX_T(opline->result.var).var.ptr = retval;
+                       }
                }
-       } else {
-               if (return_value_used) {
-                       ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                       INIT_ZVAL(*EX_T(opline->result.var).var.ptr);
-                       Z_LVAL_P(EX_T(opline->result.var).var.ptr) = failure_retval;
-                       Z_TYPE_P(EX_T(opline->result.var).var.ptr) = IS_BOOL;
-               }
+
+       } else if (RETURN_VALUE_USED(opline)) {
+               zval *retval;
+
+               ALLOC_ZVAL(retval);
+               ZVAL_BOOL(retval, failure_retval);
+               INIT_PZVAL(retval);
+               AI_SET_PTR(&EX_T(opline->result.var), retval);
        }
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval tmp, *varname;
        HashTable *target_symbol_table;
 
 
+       SAVE_OPLINE();
        if (IS_CV == IS_CV && (opline->extended_value & ZEND_QUICK_SET)) {
                if (EG(active_symbol_table)) {
-                       zend_execute_data *ex = EX(prev_execute_data);
                        zend_compiled_variable *cv = &CV_DEF_OF(opline->op1.var);
 
-                       if (zend_hash_quick_del(EG(active_symbol_table), cv->name, cv->name_len+1, cv->hash_value) == SUCCESS) {
-                               while (ex && ex->symbol_table == EG(active_symbol_table)) {
-                                       int i;
-
-                                       if (ex->op_array) {
-                                               for (i = 0; i < ex->op_array->last_var; i++) {
-                                                       if (ex->op_array->vars[i].hash_value == cv->hash_value &&
-                                                               ex->op_array->vars[i].name_len == cv->name_len &&
-                                                               !memcmp(ex->op_array->vars[i].name, cv->name, cv->name_len)) {
-                                                               ex->CVs[i] = NULL;
-                                                               break;
-                                                       }
-                                               }
-                                       }
-                                       ex = ex->prev_execute_data;
-                               }
-                       }
-                       EX(CVs)[opline->op1.var] = NULL;
-               } else if (EX(CVs)[opline->op1.var]) {
-                       zval_ptr_dtor(EX(CVs)[opline->op1.var]);
-                       EX(CVs)[opline->op1.var] = NULL;
+                       zend_delete_variable(EX(prev_execute_data), EG(active_symbol_table),  cv->name, cv->name_len+1, cv->hash_value TSRMLS_CC);
+                       EX_CV(opline->op1.var) = NULL;
+               } else if (EX_CV(opline->op1.var)) {
+                       zval_ptr_dtor(EX_CV(opline->op1.var));
+                       EX_CV(opline->op1.var) = NULL;
                }
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
-       varname = _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+       varname = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
 
        if (IS_CV != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-               tmp = *varname;
+               ZVAL_COPY_VALUE(&tmp, varname);
                zval_copy_ctor(&tmp);
                convert_to_string(&tmp);
                varname = &tmp;
@@ -22903,39 +24504,22 @@ static int ZEND_FASTCALL  ZEND_UNSET_VAR_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARG
                ulong hash_value = zend_inline_hash_func(varname->value.str.val, varname->value.str.len+1);
 
                target_symbol_table = zend_get_target_symbol_table(opline->extended_value & ZEND_FETCH_TYPE_MASK TSRMLS_CC);
-               if (zend_hash_quick_del(target_symbol_table, varname->value.str.val, varname->value.str.len+1, hash_value) == SUCCESS) {
-                       zend_execute_data *ex = execute_data;
-
-                       do {
-                               int i;
-
-                               if (ex->op_array) {
-                                       for (i = 0; i < ex->op_array->last_var; i++) {
-                                               if (ex->op_array->vars[i].hash_value == hash_value &&
-                                                       ex->op_array->vars[i].name_len == varname->value.str.len &&
-                                                       !memcmp(ex->op_array->vars[i].name, varname->value.str.val, varname->value.str.len)) {
-                                                       ex->CVs[i] = NULL;
-                                                       break;
-                                               }
-                                       }
-                               }
-                               ex = ex->prev_execute_data;
-                       } while (ex && ex->symbol_table == target_symbol_table);
-               }
+               zend_delete_variable(execute_data, target_symbol_table, varname->value.str.val, varname->value.str.len+1, hash_value TSRMLS_CC);
        }
 
-       if (varname == &tmp) {
+       if (IS_CV != IS_CONST && varname == &tmp) {
                zval_dtor(&tmp);
        } else if (IS_CV == IS_VAR || IS_CV == IS_CV) {
                zval_ptr_dtor(&varname);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *array_ptr, **array_ptr_ptr;
        HashTable *fe_ht;
@@ -22943,10 +24527,13 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS
        zend_class_entry *ce = NULL;
        zend_bool is_empty = 0;
 
+       SAVE_OPLINE();
+
        if (opline->extended_value & ZEND_FE_RESET_VARIABLE) {
-               array_ptr_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+               array_ptr_ptr = _get_zval_ptr_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
                if (array_ptr_ptr == NULL || array_ptr_ptr == &EG(uninitialized_zval_ptr)) {
-                       ALLOC_INIT_ZVAL(array_ptr);
+                       MAKE_STD_ZVAL(array_ptr);
+                       ZVAL_NULL(array_ptr);
                } else if (Z_TYPE_PP(array_ptr_ptr) == IS_OBJECT) {
                        if(Z_OBJ_HT_PP(array_ptr_ptr)->get_class_entry == NULL) {
                                zend_error(E_WARNING, "foreach() cannot iterate over objects without PHP class");
@@ -22970,7 +24557,7 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS
                        Z_ADDREF_P(array_ptr);
                }
        } else {
-               array_ptr = _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+               array_ptr = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
                if (0) { /* IS_TMP_VAR */
                        zval *tmp;
 
@@ -23006,7 +24593,7 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS
        if (ce && ce->get_iterator) {
                iter = ce->get_iterator(ce, array_ptr, opline->extended_value & ZEND_FE_RESET_REFERENCE TSRMLS_CC);
 
-               if (iter && !EG(exception)) {
+               if (iter && EXPECTED(EG(exception) == NULL)) {
                        array_ptr = zend_iterator_wrap(iter TSRMLS_CC);
                } else {
                        if (opline->extended_value & ZEND_FE_RESET_VARIABLE) {
@@ -23018,18 +24605,18 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS
                                zend_throw_exception_ex(NULL, 0 TSRMLS_CC, "Object of type %s did not create an Iterator", ce->name);
                        }
                        zend_throw_exception_internal(NULL TSRMLS_CC);
-                       ZEND_VM_NEXT_OPCODE();
+                       HANDLE_EXCEPTION();
                }
        }
 
-       AI_SET_PTR(EX_T(opline->result.var).var, array_ptr);
        PZVAL_LOCK(array_ptr);
+       AI_SET_PTR(&EX_T(opline->result.var), array_ptr);
 
        if (iter) {
                iter->index = 0;
                if (iter->funcs->rewind) {
                        iter->funcs->rewind(iter TSRMLS_CC);
-                       if (EG(exception)) {
+                       if (UNEXPECTED(EG(exception) != NULL)) {
                                Z_DELREF_P(array_ptr);
                                zval_ptr_dtor(&array_ptr);
                                if (opline->extended_value & ZEND_FE_RESET_VARIABLE) {
@@ -23037,11 +24624,11 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS
                                } else {
 
                                }
-                               ZEND_VM_NEXT_OPCODE();
+                               HANDLE_EXCEPTION();
                        }
                }
                is_empty = iter->funcs->valid(iter TSRMLS_CC) != SUCCESS;
-               if (EG(exception)) {
+               if (UNEXPECTED(EG(exception) != NULL)) {
                        Z_DELREF_P(array_ptr);
                        zval_ptr_dtor(&array_ptr);
                        if (opline->extended_value & ZEND_FE_RESET_VARIABLE) {
@@ -23049,7 +24636,7 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS
                        } else {
 
                        }
-                       ZEND_VM_NEXT_OPCODE();
+                       HANDLE_EXCEPTION();
                }
                iter->index = -1; /* will be set to 0 before using next handler */
        } else if ((fe_ht = HASH_OF(array_ptr)) != NULL) {
@@ -23086,19 +24673,21 @@ static int ZEND_FASTCALL  ZEND_FE_RESET_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS
        if (is_empty) {
                ZEND_VM_JMP(EX(op_array)->opcodes+opline->op2.opline_num);
        } else {
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 }
 
 static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval **value;
        zend_bool isset = 1;
 
+       SAVE_OPLINE();
        if (IS_CV == IS_CV && (opline->extended_value & ZEND_QUICK_SET)) {
-               if (EX(CVs)[opline->op1.var]) {
-                       value = EX(CVs)[opline->op1.var];
+               if (EX_CV(opline->op1.var)) {
+                       value = EX_CV(opline->op1.var);
                } else if (EG(active_symbol_table)) {
                        zend_compiled_variable *cv = &CV_DEF_OF(opline->op1.var);
 
@@ -23111,10 +24700,10 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_CV_HANDLER(ZEND_OPCODE_HAN
        } else {
                HashTable *target_symbol_table;
 
-               zval tmp, *varname = _get_zval_ptr_cv(opline->op1.var, BP_VAR_IS TSRMLS_CC);
+               zval tmp, *varname = _get_zval_ptr_cv_BP_VAR_IS(EX_CVs(), opline->op1.var TSRMLS_CC);
 
                if (IS_CV != IS_CONST && Z_TYPE_P(varname) != IS_STRING) {
-                       tmp = *varname;
+                       ZVAL_COPY_VALUE(&tmp, varname);
                        zval_copy_ctor(&tmp);
                        convert_to_string(&tmp);
                        varname = &tmp;
@@ -23132,38 +24721,39 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_VAR_SPEC_CV_HANDLER(ZEND_OPCODE_HAN
                        }
                }
 
-               if (varname == &tmp) {
+               if (IS_CV != IS_CONST && varname == &tmp) {
                        zval_dtor(&tmp);
                }
 
        }
 
-       Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
-
        if (opline->extended_value & ZEND_ISSET) {
-               if (isset && Z_TYPE_PP(value) == IS_NULL) {
-                       Z_LVAL(EX_T(opline->result.var).tmp_var) = 0;
+               if (isset && Z_TYPE_PP(value) != IS_NULL) {
+                       ZVAL_BOOL(&EX_T(opline->result.var).tmp_var, 1);
                } else {
-                       Z_LVAL(EX_T(opline->result.var).tmp_var) = isset;
+                       ZVAL_BOOL(&EX_T(opline->result.var).tmp_var, 0);
                }
        } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
                if (!isset || !i_zend_is_true(*value)) {
-                       Z_LVAL(EX_T(opline->result.var).tmp_var) = 1;
+                       ZVAL_BOOL(&EX_T(opline->result.var).tmp_var, 1);
                } else {
-                       Z_LVAL(EX_T(opline->result.var).tmp_var) = 0;
+                       ZVAL_BOOL(&EX_T(opline->result.var).tmp_var, 0);
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_EXIT_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
 #if 0 || (IS_CV != IS_UNUSED)
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       SAVE_OPLINE();
        if (IS_CV != IS_UNUSED) {
 
-               zval *ptr = _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+               zval *ptr = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
 
                if (Z_TYPE_P(ptr) == IS_LONG) {
                        EG(exit_status) = Z_LVAL_P(ptr);
@@ -23174,17 +24764,20 @@ static int ZEND_FASTCALL  ZEND_EXIT_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
        }
 #endif
        zend_bailout();
-       ZEND_VM_NEXT_OPCODE();
+       ZEND_VM_NEXT_OPCODE(); /* Never reached */
 }
 
 static int ZEND_FASTCALL  ZEND_JMP_SET_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       zval *value;
 
-       zval *value = _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+       SAVE_OPLINE();
+       value = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
 
        if (i_zend_is_true(value)) {
-               EX_T(opline->result.var).tmp_var = *value;
+               ZVAL_COPY_VALUE(&EX_T(opline->result.var).tmp_var, value);
                zendi_zval_copy_ctor(EX_T(opline->result.var).tmp_var);
 
 #if DEBUG_ZEND>=2
@@ -23193,30 +24786,38 @@ static int ZEND_FASTCALL  ZEND_JMP_SET_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
                ZEND_VM_JMP(opline->op2.jmp_addr);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_QM_ASSIGN_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       zval *value;
 
-       zval *value = _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+       SAVE_OPLINE();
+       value = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       EX_T(opline->result.var).tmp_var = *value;
+       ZVAL_COPY_VALUE(&EX_T(opline->result.var).tmp_var, value);
        if (!0) {
                zval_copy_ctor(&EX_T(opline->result.var).tmp_var);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INSTANCEOF_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *expr = _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+       zval *expr;
        zend_bool result;
 
+       SAVE_OPLINE();
+       expr = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+
        if (Z_TYPE_P(expr) == IS_OBJECT && Z_OBJ_HT_P(expr)->get_class_entry) {
                result = instanceof_function(Z_OBJCE_P(expr), EX_T(opline->op2.var).class_entry TSRMLS_CC);
        } else {
@@ -23224,282 +24825,317 @@ static int ZEND_FASTCALL  ZEND_INSTANCEOF_SPEC_CV_HANDLER(ZEND_OPCODE_HANDLER_AR
        }
        ZVAL_BOOL(&EX_T(opline->result.var).tmp_var, result);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        add_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SUB_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        sub_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MUL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        mul_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_DIV_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        div_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MOD_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        mod_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        shift_left_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        shift_right_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        concat_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        is_identical_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        is_identical_function(result,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        Z_LVAL_P(result) = !Z_LVAL_P(result);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) == 0));
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) != 0));
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) < 0));
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) <= 0));
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        bitwise_or_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        bitwise_and_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        bitwise_xor_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        boolean_xor_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
                opline->op2.zv TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op_data1;
-       zval **object_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       zval **object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
        zval *object;
        zval *property = opline->op2.zv;
-       zval *value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
+       zval *value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
        znode_op *result = &opline->result;
        int have_get_ptr = 0;
 
-       if (IS_CV == IS_VAR && !object_ptr) {
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
 
-       EX_T(result->var).var.ptr_ptr = NULL;
        make_real_object(object_ptr TSRMLS_CC);
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to assign property of non-object");
 
                FREE_OP(free_op_data1);
 
                if (RETURN_VALUE_USED(opline)) {
-                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                       EX_T(result->var).var.ptr_ptr = NULL;
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                }
        } else {
                /* here we are sure we are dealing with an object */
@@ -23517,9 +25153,9 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_CONST(int (*bi
                                have_get_ptr = 1;
                                binary_op(*zptr, *zptr, value TSRMLS_CC);
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = *zptr;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(*zptr);
+                                       EX_T(opline->result.var).var.ptr = *zptr;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -23556,17 +25192,17 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_CONST(int (*bi
                                        Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
                                }
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = z;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(z);
+                                       EX_T(opline->result.var).var.ptr = z;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                                zval_ptr_dtor(&z);
                        } else {
                                zend_error(E_WARNING, "Attempt to assign property of non-object");
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                                       EX_T(result->var).var.ptr_ptr = NULL;
-                                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                                       PZVAL_LOCK(&EG(uninitialized_zval));
+                                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -23580,66 +25216,71 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_CONST(int (*bi
        }
 
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_CONST(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op_data2, free_op_data1;
        zval **var_ptr;
        zval *value;
 
+       SAVE_OPLINE();
        switch (opline->extended_value) {
                case ZEND_ASSIGN_OBJ:
                        return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                        break;
                case ZEND_ASSIGN_DIM: {
-                               zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_RW TSRMLS_CC);
+                               zval **container = _get_zval_ptr_ptr_cv_BP_VAR_RW(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-                               if (IS_CV == IS_VAR && !container) {
+                               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-                               } else if (Z_TYPE_PP(container) == IS_OBJECT) {
+                               } else if (UNEXPECTED(Z_TYPE_PP(container) == IS_OBJECT)) {
                                        if (IS_CV == IS_VAR && !0) {
                                                Z_ADDREF_PP(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
                                        }
                                        return zend_binary_assign_op_obj_helper_SPEC_CV_CONST(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                                } else {
-                                       zend_op *op_data = opline+1;
                                        zval *dim = opline->op2.zv;
 
-                                       zend_fetch_dimension_address(&EX_T(op_data->op2.var), container, dim, IS_CONST, BP_VAR_RW TSRMLS_CC);
-                                       value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-                                       var_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-                                       ZEND_VM_INC_OPCODE();
+                                       zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), container, dim, IS_CONST, BP_VAR_RW TSRMLS_CC);
+                                       value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+                                       var_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
                                }
                        }
                        break;
                default:
                        value = opline->op2.zv;
-                       var_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_RW TSRMLS_CC);
+                       var_ptr = _get_zval_ptr_ptr_cv_BP_VAR_RW(EX_CVs(), opline->op1.var TSRMLS_CC);
                        /* do nothing */
                        break;
        }
 
-       if (!var_ptr) {
+       if (UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
        }
 
-       if (*var_ptr == EG(error_zval_ptr)) {
+       if (UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
 
 
+               CHECK_EXCEPTION();
+               if (opline->extended_value == ZEND_ASSIGN_DIM) {
+                       ZEND_VM_INC_OPCODE();
+               }
                ZEND_VM_NEXT_OPCODE();
        }
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *objval = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -23652,15 +25293,20 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_CONST(int (*binary
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *var_ptr);
                PZVAL_LOCK(*var_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *var_ptr);
        }
 
        if (opline->extended_value == ZEND_ASSIGN_DIM) {
                FREE_OP(free_op_data1);
                FREE_OP_VAR_PTR(free_op_data2);
-       }
 
+               CHECK_EXCEPTION();
+               ZEND_VM_INC_OPCODE();
+       } else {
+
+               CHECK_EXCEPTION();
+       }
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -23721,29 +25367,35 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_H
 
 static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval **object_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       zval **object_ptr;
        zval *object;
-       zval *property = opline->op2.zv;
-       zval **retval = &EX_T(opline->result.var).var.ptr;
+       zval *property;
+       zval **retval;
        int have_get_ptr = 0;
 
-       if (IS_CV == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+       property = opline->op2.zv;
+       retval = &EX_T(opline->result.var).var.ptr;
+
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
 
                if (RETURN_VALUE_USED(opline)) {
-                       *retval = EG(uninitialized_zval_ptr);
-                       PZVAL_LOCK(*retval);
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       *retval = &EG(uninitialized_zval);
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -23771,7 +25423,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_CONST(incdec_t
                if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -23791,8 +25443,8 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_CONST(incdec_t
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                        if (RETURN_VALUE_USED(opline)) {
-                               *retval = EG(uninitialized_zval_ptr);
-                               PZVAL_LOCK(*retval);
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               *retval = &EG(uninitialized_zval);
                        }
                }
        }
@@ -23803,6 +25455,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_CONST(incdec_t
 
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -23818,26 +25471,32 @@ static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HAN
 
 static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CONST(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval **object_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       zval **object_ptr;
        zval *object;
-       zval *property = opline->op2.zv;
-       zval *retval = &EX_T(opline->result.var).tmp_var;
+       zval *property;
+       zval *retval;
        int have_get_ptr = 0;
 
-       if (IS_CV == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+       property = opline->op2.zv;
+       retval = &EX_T(opline->result.var).tmp_var;
+
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
 
-               *retval = *EG(uninitialized_zval_ptr);
+               ZVAL_NULL(retval);
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -23853,7 +25512,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CONST(incdec_t
                        have_get_ptr = 1;
                        SEPARATE_ZVAL_IF_NOT_REF(zptr);
 
-                       *retval = **zptr;
+                       ZVAL_COPY_VALUE(retval, *zptr);
                        zendi_zval_copy_ctor(*retval);
 
                        incdec_op(*zptr);
@@ -23866,7 +25525,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CONST(incdec_t
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
                        zval *z_copy;
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -23876,12 +25535,11 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CONST(incdec_t
                                }
                                z = value;
                        }
-                       *retval = *z;
+                       ZVAL_COPY_VALUE(retval, z);
                        zendi_zval_copy_ctor(*retval);
                        ALLOC_ZVAL(z_copy);
-                       *z_copy = *z;
+                       INIT_PZVAL_COPY(z_copy, z);
                        zendi_zval_copy_ctor(*z_copy);
-                       INIT_PZVAL(z_copy);
                        incdec_op(z_copy);
                        Z_ADDREF_P(z);
                        Z_OBJ_HT_P(object)->write_property(object, property, z_copy, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
@@ -23889,7 +25547,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CONST(incdec_t
                        zval_ptr_dtor(&z);
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-                       *retval = *EG(uninitialized_zval_ptr);
+                       ZVAL_NULL(retval);
                }
        }
 
@@ -23899,6 +25557,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CONST(incdec_t
 
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -23914,194 +25573,193 @@ static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HA
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *dim = opline->op2.zv;
        zval **container;
 
+       SAVE_OPLINE();
+
        if ((opline->extended_value & ZEND_FETCH_ADD_LOCK) &&
            IS_CV != IS_CV &&
            EX_T(opline->op1.var).var.ptr_ptr) {
                PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
        }
-       container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
-       if (IS_CV == IS_VAR && !container) {
+       container = _get_zval_ptr_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address_read(!RETURN_VALUE_USED(opline)?NULL:&EX_T(opline->result.var), container, dim, IS_CONST, BP_VAR_R TSRMLS_CC);
+       zend_fetch_dimension_address_read(!RETURN_VALUE_USED(opline)?NULL:&EX_T(opline->result.var), container, opline->op2.zv, IS_CONST, BP_VAR_R TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *dim = opline->op2.zv;
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       zval **container;
 
-       if (IS_CV == IS_VAR && !container) {
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_CONST, BP_VAR_W TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, opline->op2.zv, IS_CONST, BP_VAR_W TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
        /* We are going to assign the result by reference */
-       if (opline->extended_value && EX_T(opline->result.var).var.ptr_ptr) {
-               Z_DELREF_PP(EX_T(opline->result.var).var.ptr_ptr);
-               SEPARATE_ZVAL_TO_MAKE_IS_REF(EX_T(opline->result.var).var.ptr_ptr);
-               Z_ADDREF_PP(EX_T(opline->result.var).var.ptr_ptr);
+       if (UNEXPECTED(opline->extended_value != 0)) {
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+
+               if (retval_ptr) {
+                       Z_DELREF_PP(retval_ptr);
+                       SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
+                       Z_ADDREF_PP(retval_ptr);
+               }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *dim = opline->op2.zv;
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_RW TSRMLS_CC);
+       zval **container;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_RW(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && !container) {
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_CONST, BP_VAR_RW TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, opline->op2.zv, IS_CONST, BP_VAR_RW TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       zval **container;
 
-       zval *dim = opline->op2.zv;
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_IS TSRMLS_CC);
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_IS(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && !container) {
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, dim, IS_CONST, BP_VAR_IS TSRMLS_CC);
+       zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, opline->op2.zv, IS_CONST, BP_VAR_IS TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *dim = opline->op2.zv;
        zval **container;
 
+       SAVE_OPLINE();
+
        if (ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))) {
-               container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
-               if (IS_CV == IS_VAR && !container) {
+               container = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_CONST, BP_VAR_W TSRMLS_CC);
-               if (IS_CV == IS_VAR && 0 &&
-                   READY_TO_DESTROY(free_op1.var)) {
-                       AI_USE_PTR(EX_T(opline->result.var).var);
-                       if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                           Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                               SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-                       }
+               zend_fetch_dimension_address(&EX_T(opline->result.var), container, opline->op2.zv, IS_CONST, BP_VAR_W TSRMLS_CC);
+               if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+                       EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
                }
        } else {
                if (IS_CONST == IS_UNUSED) {
                        zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
                }
-               container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
-               if (IS_CV == IS_VAR && !container) {
+               container = _get_zval_ptr_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, dim, IS_CONST, BP_VAR_R TSRMLS_CC);
+               zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, opline->op2.zv, IS_CONST, BP_VAR_R TSRMLS_CC);
        }
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_UNSET_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_UNSET TSRMLS_CC);
-       zval *dim = opline->op2.zv;
+       zval **container;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_UNSET(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       /* Not needed in DIM_UNSET
-       if (opline->extended_value & ZEND_FETCH_ADD_LOCK) {
-               PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
-       }
-       */
        if (IS_CV == IS_CV) {
                if (container != &EG(uninitialized_zval_ptr)) {
                        SEPARATE_ZVAL_IF_NOT_REF(container);
                }
        }
-       if (IS_CV == IS_VAR && !container) {
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_CONST, BP_VAR_UNSET TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, opline->op2.zv, IS_CONST, BP_VAR_UNSET TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
-       if (EX_T(opline->result.var).var.ptr_ptr == NULL) {
+       if (UNEXPECTED(EX_T(opline->result.var).var.ptr_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
        } else {
                zend_free_op free_res;
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
 
-               PZVAL_UNLOCK(*EX_T(opline->result.var).var.ptr_ptr, &free_res);
-               if (EX_T(opline->result.var).var.ptr_ptr != &EG(uninitialized_zval_ptr)) {
-                       SEPARATE_ZVAL_IF_NOT_REF(EX_T(opline->result.var).var.ptr_ptr);
+               PZVAL_UNLOCK(*retval_ptr, &free_res);
+               if (retval_ptr != &EG(uninitialized_zval_ptr)) {
+                       SEPARATE_ZVAL_IF_NOT_REF(retval_ptr);
                }
-               PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
+               PZVAL_LOCK(*retval_ptr);
                FREE_OP_VAR_PTR(free_res);
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
        }
-       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_CV_CONST(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_CV_CONST(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *container = _get_zval_ptr_cv(opline->op1.var, type TSRMLS_CC);
+       zval *container;
 
-       zval *offset  = opline->op2.zv;
+       zval *offset;
 
-       if (Z_TYPE_P(container) != IS_OBJECT || !Z_OBJ_HT_P(container)->read_property) {
-               if (type != BP_VAR_IS) {
-                       zend_error(E_NOTICE, "Trying to get property of non-object");
-               }
+       SAVE_OPLINE();
+       container = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+       offset  = opline->op2.zv;
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               zend_error(E_NOTICE, "Trying to get property of non-object");
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
 
        } else {
@@ -24112,7 +25770,7 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_CV_CONST(i
                }
 
                /* here we are sure we are dealing with an object */
-               retval = Z_OBJ_HT_P(container)->read_property(container, offset, type, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
                if (!RETURN_VALUE_USED(opline)) {
                        if (Z_REFCOUNT_P(retval) == 0) {
@@ -24121,8 +25779,8 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_CV_CONST(i
                                FREE_ZVAL(retval);
                        }
                } else {
-                       AI_SET_PTR(EX_T(opline->result.var).var, retval);
                        PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                }
 
                if (0) {
@@ -24132,21 +25790,25 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_CV_CONST(i
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_property_address_read_helper_SPEC_CV_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_fetch_property_address_read_helper_SPEC_CV_CONST(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *property = opline->op2.zv;
+       zval *property;
        zval **container;
 
+       SAVE_OPLINE();
+       property = opline->op2.zv;
+
        if (IS_CV == IS_VAR && (opline->extended_value & ZEND_FETCH_ADD_LOCK)) {
                PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
                EX_T(opline->op1.var).var.ptr = *EX_T(opline->op1.var).var.ptr_ptr;
@@ -24155,46 +25817,49 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HAN
        if (0) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
-       if (IS_CV == IS_VAR && !container) {
+       container = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
+
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
        if (0) {
                zval_ptr_dtor(&property);
        } else {
 
        }
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
        /* We are going to assign the result by reference */
        if (opline->extended_value & ZEND_FETCH_MAKE_REF) {
-               Z_DELREF_PP(EX_T(opline->result.var).var.ptr_ptr);
-               SEPARATE_ZVAL_TO_MAKE_IS_REF(EX_T(opline->result.var).var.ptr_ptr);
-               Z_ADDREF_PP(EX_T(opline->result.var).var.ptr_ptr);
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+
+               Z_DELREF_PP(retval_ptr);
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
+               Z_ADDREF_PP(retval_ptr);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *property = opline->op2.zv;
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_RW TSRMLS_CC);
+       zval *property;
+       zval **container;
+
+       SAVE_OPLINE();
+       property = opline->op2.zv;
+       container = _get_zval_ptr_ptr_cv_BP_VAR_RW(EX_CVs(), opline->op1.var TSRMLS_CC);
 
        if (0) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       if (IS_CV == IS_VAR && !container) {
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_RW TSRMLS_CC);
@@ -24203,37 +25868,83 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HA
        } else {
 
        }
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_property_address_read_helper_SPEC_CV_CONST(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       USE_OPLINE
+
+       zval *container;
+
+       zval *offset;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_cv_BP_VAR_IS(EX_CVs(), opline->op1.var TSRMLS_CC);
+       offset  = opline->op2.zv;
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               if (RETURN_VALUE_USED(opline)) {
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+               }
+
+       } else {
+               zval *retval;
+
+               if (0) {
+                       MAKE_REAL_ZVAL_PTR(offset);
+               }
+
+               /* here we are sure we are dealing with an object */
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+
+               if (!RETURN_VALUE_USED(opline)) {
+                       if (Z_REFCOUNT_P(retval) == 0) {
+                               GC_REMOVE_ZVAL_FROM_BUFFER(retval);
+                               zval_dtor(retval);
+                               FREE_ZVAL(retval);
+                       }
+               } else {
+                       PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
+               }
+
+               if (0) {
+                       zval_ptr_dtor(&offset);
+               } else {
+
+               }
+       }
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        if (ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))) {
                /* Behave like FETCH_OBJ_W */
                zend_free_op free_op1;
-               zval *property = opline->op2.zv;
-               zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+               zval *property;
+               zval **container;
+
+               SAVE_OPLINE();
+               property = opline->op2.zv;
+               container = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
 
                if (0) {
                        MAKE_REAL_ZVAL_PTR(property);
                }
-               if (IS_CV == IS_VAR && !container) {
+               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
                }
                zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
@@ -24242,27 +25953,27 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_CONST_HANDLER(ZEND_OPC
                } else {
 
                }
-               if (IS_CV == IS_VAR && 0 &&
-                   READY_TO_DESTROY(free_op1.var)) {
-                       AI_USE_PTR(EX_T(opline->result.var).var);
-                       if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                           Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                               SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-                       }
+               if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+                       EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
-               return zend_fetch_property_address_read_helper_SPEC_CV_CONST(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_fetch_property_address_read_helper_SPEC_CV_CONST(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_res;
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
-       zval *property = opline->op2.zv;
+       zval **container;
+       zval *property;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+       property = opline->op2.zv;
 
        if (IS_CV == IS_CV) {
                if (container != &EG(uninitialized_zval_ptr)) {
@@ -24272,7 +25983,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_CV_CONST_HANDLER(ZEND_OPCODE
        if (0) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       if (IS_CV == IS_VAR && !container) {
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_UNSET TSRMLS_CC);
@@ -24281,13 +25992,8 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_CV_CONST_HANDLER(ZEND_OPCODE
        } else {
 
        }
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
        PZVAL_UNLOCK(*EX_T(opline->result.var).var.ptr_ptr, &free_res);
@@ -24296,24 +26002,28 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_CV_CONST_HANDLER(ZEND_OPCODE
        }
        PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
        FREE_OP_VAR_PTR(free_res);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
+
+       zval **object_ptr;
+       zval *property_name;
 
-       zval **object_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
-       zval *property_name = opline->op2.zv;
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+       property_name = opline->op2.zv;
 
        if (0) {
                MAKE_REAL_ZVAL_PTR(property_name);
        }
-       if (IS_CV == IS_VAR && !object_ptr) {
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, op_data->op1_type, &op_data->op1, EX(Ts), ZEND_ASSIGN_OBJ, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), ZEND_ASSIGN_OBJ, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
        if (0) {
                zval_ptr_dtor(&property_name);
        } else {
@@ -24321,18 +26031,21 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HAND
        }
 
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
 
-       zval **object_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       zval **object_ptr;
 
-       if (IS_CV == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
        if (Z_TYPE_PP(object_ptr) == IS_OBJECT) {
@@ -24342,7 +26055,7 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HAND
                if (0) {
                        MAKE_REAL_ZVAL_PTR(property_name);
                }
-               zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, op_data->op1_type, &op_data->op1, EX(Ts), ZEND_ASSIGN_DIM, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+               zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), ZEND_ASSIGN_DIM, ((IS_CONST == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
                if (0) {
                        zval_ptr_dtor(&property_name);
                } else {
@@ -24354,27 +26067,41 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HAND
                zval *dim = opline->op2.zv;
                zval **variable_ptr_ptr;
 
-               zend_fetch_dimension_address(&EX_T(op_data->op2.var), object_ptr, dim, IS_CONST, BP_VAR_W TSRMLS_CC);
+               zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), object_ptr, dim, IS_CONST, BP_VAR_W TSRMLS_CC);
 
-               value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-               variable_ptr_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-               if (!variable_ptr_ptr) {
-                       if (zend_assign_to_string_offset(&EX_T(op_data->op2.var), value, op_data->op1_type TSRMLS_CC)) {
+               value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+               variable_ptr_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
+               if (UNEXPECTED(variable_ptr_ptr == NULL)) {
+                       if (zend_assign_to_string_offset(&EX_T((opline+1)->op2.var), value, (opline+1)->op1_type TSRMLS_CC)) {
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-                                       ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                                       INIT_PZVAL(EX_T(opline->result.var).var.ptr);
-                                       ZVAL_STRINGL(EX_T(opline->result.var).var.ptr, Z_STRVAL_P(EX_T(op_data->op2.var).str_offset.str)+EX_T(op_data->op2.var).str_offset.offset, 1, 1);
+                                       zval *retval;
+
+                                       ALLOC_ZVAL(retval);
+                                       ZVAL_STRINGL(retval, Z_STRVAL_P(EX_T((opline+1)->op2.var).str_offset.str)+EX_T((opline+1)->op2.var).str_offset.offset, 1, 1);
+                                       INIT_PZVAL(retval);
+                                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                                }
                        } else if (RETURN_VALUE_USED(opline)) {
-                               AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                               PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+                       }
+               } else if (UNEXPECTED(*variable_ptr_ptr == &EG(error_zval))) {
+                       if (IS_TMP_FREE(free_op_data1)) {
+                               zval_dtor(value);
+                       }
+                       if (RETURN_VALUE_USED(opline)) {
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                        }
                } else {
-                       value = zend_assign_to_variable(variable_ptr_ptr, value, IS_TMP_FREE(free_op_data1) TSRMLS_CC);
+                       if (IS_TMP_FREE(free_op_data1)) {
+                               value = zend_assign_tmp_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+                       } else {
+                               value = zend_assign_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+                       }
                        if (RETURN_VALUE_USED(opline)) {
-                               AI_SET_PTR(EX_T(opline->result.var).var, value);
                                PZVAL_LOCK(value);
+                               AI_SET_PTR(&EX_T(opline->result.var), value);
                        }
                }
                FREE_OP_VAR_PTR(free_op_data2);
@@ -24382,71 +26109,94 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HAND
        }
 
        /* assign_dim has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       zval *value;
+       zval **variable_ptr_ptr;
 
-       zval *value = opline->op2.zv;
-       zval **variable_ptr_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       SAVE_OPLINE();
+       value = opline->op2.zv;
+       variable_ptr_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && !variable_ptr_ptr) {
+       if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr_ptr == NULL)) {
                if (zend_assign_to_string_offset(&EX_T(opline->op1.var), value, IS_CONST TSRMLS_CC)) {
                        if (RETURN_VALUE_USED(opline)) {
-                               EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-                               ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                               INIT_PZVAL(EX_T(opline->result.var).var.ptr);
-                               ZVAL_STRINGL(EX_T(opline->result.var).var.ptr, Z_STRVAL_P(EX_T(opline->op1.var).str_offset.str)+EX_T(opline->op1.var).str_offset.offset, 1, 1);
+                               zval *retval;
+
+                               ALLOC_ZVAL(retval);
+                               ZVAL_STRINGL(retval, Z_STRVAL_P(EX_T(opline->op1.var).str_offset.str)+EX_T(opline->op1.var).str_offset.offset, 1, 1);
+                               INIT_PZVAL(retval);
+                               AI_SET_PTR(&EX_T(opline->result.var), retval);
                        }
                } else if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+               }
+       } else if (IS_CV == IS_VAR && UNEXPECTED(*variable_ptr_ptr == &EG(error_zval))) {
+               if (0) {
+                       zval_dtor(value);
+               }
+               if (RETURN_VALUE_USED(opline)) {
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
        } else {
-               value = zend_assign_to_variable(variable_ptr_ptr, value, 0 TSRMLS_CC);
+               if (0) {
+                       value = zend_assign_tmp_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+               } else {
+                       value = zend_assign_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+               }
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, value);
                        PZVAL_LOCK(value);
+                       AI_SET_PTR(&EX_T(opline->result.var), value);
                }
        }
 
        /* zend_assign_to_variable() always takes care of op2, never free it! */
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        char *function_name_strval;
        int function_name_strlen;
 
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
        function_name = opline->op2.zv;
 
-       if (Z_TYPE_P(function_name)!=IS_STRING) {
+       if (IS_CONST != IS_CONST &&
+           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                zend_error_noreturn(E_ERROR, "Method name must be a string");
        }
 
        function_name_strval = Z_STRVAL_P(function_name);
        function_name_strlen = Z_STRLEN_P(function_name);
 
-       EX(object) = _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+       EX(object) = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       if (EX(object) && Z_TYPE_P(EX(object)) == IS_OBJECT) {
-               if (Z_OBJ_HT_P(EX(object))->get_method == NULL) {
+       if (EXPECTED(EX(object) != NULL) &&
+           EXPECTED(Z_TYPE_P(EX(object)) == IS_OBJECT)) {
+               if (UNEXPECTED(Z_OBJ_HT_P(EX(object))->get_method == NULL)) {
                        zend_error_noreturn(E_ERROR, "Object does not support method calls");
                }
 
                /* First, locate the function. */
                EX(fbc) = Z_OBJ_HT_P(EX(object))->get_method(&EX(object), function_name_strval, function_name_strlen, ((IS_CONST == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
-               if (!EX(fbc)) {
+               if (UNEXPECTED(EX(fbc) == NULL)) {
                        zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", Z_OBJ_CLASS_NAME_P(EX(object)), function_name_strval);
                }
 
@@ -24470,15 +26220,17 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_CV_CONST_HANDLER(ZEND_OPCOD
        }
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CASE_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        int switch_expr_is_overloaded=0;
 
 
+       SAVE_OPLINE();
        if (IS_CV==IS_VAR) {
                if (EX_T(opline->op1.var).var.ptr_ptr) {
                        PZVAL_LOCK(EX_T(opline->op1.var).var.ptr);
@@ -24488,7 +26240,7 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_AR
                }
        }
        is_equal_function(&EX_T(opline->result.var).tmp_var,
-                                _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
+                                _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
                                 opline->op2.zv TSRMLS_CC);
 
        if (switch_expr_is_overloaded) {
@@ -24501,47 +26253,32 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_AR
                EX_T(opline->op1.var).var.ptr_ptr = NULL;
                EX_T(opline->op1.var).var.ptr = NULL;
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *array_ptr = &EX_T(opline->result.var).tmp_var;
        zval *expr_ptr;
-       zval *offset=opline->op2.zv;
-       ulong hval;
-       long index;
 
-#if 0 || IS_CV == IS_VAR || IS_CV == IS_CV
-       zval **expr_ptr_ptr = NULL;
+       SAVE_OPLINE();
+       if ((IS_CV == IS_VAR || IS_CV == IS_CV) && opline->extended_value) {
+               zval **expr_ptr_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       if (opline->extended_value) {
-               expr_ptr_ptr=_get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
                expr_ptr = *expr_ptr_ptr;
+               Z_ADDREF_P(expr_ptr);
        } else {
-               expr_ptr=_get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
-       }
-#else
-       expr_ptr=_get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
-#endif
-
-       if (0) { /* temporary variable */
-               zval *new_expr;
+               expr_ptr=_get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+               if (0) { /* temporary variable */
+                       zval *new_expr;
 
-               ALLOC_ZVAL(new_expr);
-               INIT_PZVAL_COPY(new_expr, expr_ptr);
-               expr_ptr = new_expr;
-       } else {
-#if 0 || IS_CV == IS_VAR || IS_CV == IS_CV
-               if (opline->extended_value) {
-                       SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
-                       expr_ptr = *expr_ptr_ptr;
-                       Z_ADDREF_P(expr_ptr);
-               } else
-#endif
-               if (IS_CV == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
+                       ALLOC_ZVAL(new_expr);
+                       INIT_PZVAL_COPY(new_expr, expr_ptr);
+                       expr_ptr = new_expr;
+               } else if (IS_CV == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
                        zval *new_expr;
 
                        ALLOC_ZVAL(new_expr);
@@ -24552,7 +26289,13 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CONST_HANDLER(ZEND_OPCO
                        Z_ADDREF_P(expr_ptr);
                }
        }
-       if (offset) {
+
+       if (IS_CONST != IS_UNUSED) {
+
+               zval *offset = opline->op2.zv;
+               ulong hval;
+               long index;
+
                switch (Z_TYPE_P(offset)) {
                        case IS_DOUBLE:
                                index = zend_dval_to_lval(Z_DVAL_P(offset));
@@ -24561,7 +26304,7 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CONST_HANDLER(ZEND_OPCO
                        case IS_BOOL:
                                index = Z_LVAL_P(offset);
 num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(array_ptr), index, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_index_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), index, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_STRING:
                                if (IS_CONST == IS_CONST) {
@@ -24574,10 +26317,10 @@ num_index:
                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                        }
                                }
-                               zend_hash_quick_update(Z_ARRVAL_P(array_ptr), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_quick_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_NULL:
-                               zend_hash_update(Z_ARRVAL_P(array_ptr), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
                                break;
                        default:
                                zend_error(E_WARNING, "Illegal offset type");
@@ -24587,19 +26330,20 @@ num_index:
                }
 
        } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(array_ptr), &expr_ptr, sizeof(zval *), NULL);
+               zend_hash_next_index_insert(Z_ARRVAL(EX_T(opline->result.var).tmp_var), &expr_ptr, sizeof(zval *), NULL);
        }
-       if (opline->extended_value) {
+       if ((IS_CV == IS_VAR || IS_CV == IS_CV) && opline->extended_value) {
 
        } else {
 
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (IS_CV == IS_UNUSED) {
@@ -24613,13 +26357,17 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HAND
 
 static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_UNSET TSRMLS_CC);
-       zval *offset = opline->op2.zv;
+       zval **container;
+       zval *offset;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_UNSET(EX_CVs(), opline->op1.var TSRMLS_CC);
+       offset = opline->op2.zv;
+
        if (IS_CV != IS_VAR || container) {
                if (IS_CV == IS_CV && container != &EG(uninitialized_zval_ptr)) {
                        SEPARATE_ZVAL_IF_NOT_REF(container);
@@ -24653,24 +26401,10 @@ num_index_dim:
                                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                                        }
                                                }
-                                               if (zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval) == SUCCESS &&
-                                           ht == &EG(symbol_table)) {
-                                                       zend_execute_data *ex;
-
-                                                       for (ex = execute_data; ex; ex = ex->prev_execute_data) {
-                                                               if (ex->op_array && ex->symbol_table == ht) {
-                                                                       int i;
-
-                                                                       for (i = 0; i < ex->op_array->last_var; i++) {
-                                                                               if (ex->op_array->vars[i].hash_value == hval &&
-                                                                                   ex->op_array->vars[i].name_len == offset->value.str.len &&
-                                                                                   !memcmp(ex->op_array->vars[i].name, offset->value.str.val, offset->value.str.len)) {
-                                                                                       ex->CVs[i] = NULL;
-                                                                                       break;
-                                                                               }
-                                                                       }
-                                                               }
-                                                       }
+                                               if (ht == &EG(symbol_table)) {
+                                                       zend_delete_global_variable_ex(offset->value.str.val, offset->value.str.len, hval TSRMLS_CC);
+                                               } else {
+                                                       zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval);
                                                }
                                                if (IS_CONST == IS_CV || IS_CONST == IS_VAR) {
                                                        zval_ptr_dtor(&offset);
@@ -24687,7 +26421,7 @@ num_index_dim:
                                break;
                        }
                        case IS_OBJECT:
-                               if (!Z_OBJ_HT_P(*container)->unset_dimension) {
+                               if (UNEXPECTED(Z_OBJ_HT_P(*container)->unset_dimension == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use object as array");
                                }
                                if (0) {
@@ -24711,15 +26445,20 @@ num_index_dim:
 
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       zval **container;
+       zval *offset;
 
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_UNSET TSRMLS_CC);
-       zval *offset = opline->op2.zv;
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_UNSET(EX_CVs(), opline->op1.var TSRMLS_CC);
+       offset = opline->op2.zv;
 
        if (IS_CV != IS_VAR || container) {
                if (IS_CV == IS_CV && container != &EG(uninitialized_zval_ptr)) {
@@ -24746,19 +26485,23 @@ static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_CV_CONST_HANDLER(ZEND_OPCODE_HANDL
 
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_isset_isempty_dim_prop_obj_handler_SPEC_CV_CONST(int prop_dim, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_IS TSRMLS_CC);
+       zval **container;
        zval **value = NULL;
        int result = 0;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_IS(EX_CVs(), opline->op1.var TSRMLS_CC);
+
        if (IS_CV != IS_VAR || container) {
 
                zval *offset = opline->op2.zv;
@@ -24852,7 +26595,7 @@ num_index_prop:
                        zval tmp;
 
                        if (Z_TYPE_P(offset) != IS_LONG) {
-                               tmp = *offset;
+                               ZVAL_COPY_VALUE(&tmp, offset);
                                zval_copy_ctor(&tmp);
                                convert_to_long(&tmp);
                                offset = &tmp;
@@ -24875,13 +26618,13 @@ num_index_prop:
        }
 
        Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
-
        if (opline->extended_value & ZEND_ISSET) {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = result;
-       } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+       } else {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = !result;
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -24897,277 +26640,311 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_CONST_HANDLER(ZEND
 
 static int ZEND_FASTCALL  ZEND_ADD_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        add_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SUB_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        sub_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MUL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        mul_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_DIV_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        div_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MOD_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        mod_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        shift_left_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        shift_right_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        concat_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        is_identical_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        is_identical_function(result,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        Z_LVAL_P(result) = !Z_LVAL_P(result);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) == 0));
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) != 0));
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) < 0));
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) <= 0));
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        bitwise_or_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        bitwise_and_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        bitwise_xor_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        boolean_xor_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op2, free_op_data1;
-       zval **object_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       zval **object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
        zval *object;
-       zval *property = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval *value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
+       zval *property = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       zval *value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
        znode_op *result = &opline->result;
        int have_get_ptr = 0;
 
-       if (IS_CV == IS_VAR && !object_ptr) {
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
 
-       EX_T(result->var).var.ptr_ptr = NULL;
        make_real_object(object_ptr TSRMLS_CC);
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to assign property of non-object");
                zval_dtor(free_op2.var);
                FREE_OP(free_op_data1);
 
                if (RETURN_VALUE_USED(opline)) {
-                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                       EX_T(result->var).var.ptr_ptr = NULL;
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                }
        } else {
                /* here we are sure we are dealing with an object */
@@ -25185,9 +26962,9 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_TMP(int (*bina
                                have_get_ptr = 1;
                                binary_op(*zptr, *zptr, value TSRMLS_CC);
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = *zptr;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(*zptr);
+                                       EX_T(opline->result.var).var.ptr = *zptr;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -25224,17 +27001,17 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_TMP(int (*bina
                                        Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
                                }
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = z;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(z);
+                                       EX_T(opline->result.var).var.ptr = z;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                                zval_ptr_dtor(&z);
                        } else {
                                zend_error(E_WARNING, "Attempt to assign property of non-object");
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                                       EX_T(result->var).var.ptr_ptr = NULL;
-                                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                                       PZVAL_LOCK(&EG(uninitialized_zval));
+                                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -25248,66 +27025,71 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_TMP(int (*bina
        }
 
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_TMP(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2, free_op_data2, free_op_data1;
        zval **var_ptr;
        zval *value;
 
+       SAVE_OPLINE();
        switch (opline->extended_value) {
                case ZEND_ASSIGN_OBJ:
                        return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                        break;
                case ZEND_ASSIGN_DIM: {
-                               zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_RW TSRMLS_CC);
+                               zval **container = _get_zval_ptr_ptr_cv_BP_VAR_RW(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-                               if (IS_CV == IS_VAR && !container) {
+                               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-                               } else if (Z_TYPE_PP(container) == IS_OBJECT) {
+                               } else if (UNEXPECTED(Z_TYPE_PP(container) == IS_OBJECT)) {
                                        if (IS_CV == IS_VAR && !0) {
                                                Z_ADDREF_PP(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
                                        }
                                        return zend_binary_assign_op_obj_helper_SPEC_CV_TMP(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                                } else {
-                                       zend_op *op_data = opline+1;
-                                       zval *dim = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+                                       zval *dim = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
-                                       zend_fetch_dimension_address(&EX_T(op_data->op2.var), container, dim, IS_TMP_VAR, BP_VAR_RW TSRMLS_CC);
-                                       value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-                                       var_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-                                       ZEND_VM_INC_OPCODE();
+                                       zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), container, dim, IS_TMP_VAR, BP_VAR_RW TSRMLS_CC);
+                                       value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+                                       var_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
                                }
                        }
                        break;
                default:
-                       value = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-                       var_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_RW TSRMLS_CC);
+                       value = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+                       var_ptr = _get_zval_ptr_ptr_cv_BP_VAR_RW(EX_CVs(), opline->op1.var TSRMLS_CC);
                        /* do nothing */
                        break;
        }
 
-       if (!var_ptr) {
+       if (UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
        }
 
-       if (*var_ptr == EG(error_zval_ptr)) {
+       if (UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
                zval_dtor(free_op2.var);
 
+               CHECK_EXCEPTION();
+               if (opline->extended_value == ZEND_ASSIGN_DIM) {
+                       ZEND_VM_INC_OPCODE();
+               }
                ZEND_VM_NEXT_OPCODE();
        }
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *objval = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -25320,16 +27102,21 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_TMP(int (*binary_o
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *var_ptr);
                PZVAL_LOCK(*var_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *var_ptr);
        }
        zval_dtor(free_op2.var);
 
        if (opline->extended_value == ZEND_ASSIGN_DIM) {
                FREE_OP(free_op_data1);
                FREE_OP_VAR_PTR(free_op_data2);
-       }
 
+               CHECK_EXCEPTION();
+               ZEND_VM_INC_OPCODE();
+       } else {
+
+               CHECK_EXCEPTION();
+       }
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -25390,29 +27177,35 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HAN
 
 static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_TMP(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
-       zval **object_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       zval **object_ptr;
        zval *object;
-       zval *property = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **retval = &EX_T(opline->result.var).var.ptr;
+       zval *property;
+       zval **retval;
        int have_get_ptr = 0;
 
-       if (IS_CV == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+       property = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       retval = &EX_T(opline->result.var).var.ptr;
+
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                zval_dtor(free_op2.var);
                if (RETURN_VALUE_USED(opline)) {
-                       *retval = EG(uninitialized_zval_ptr);
-                       PZVAL_LOCK(*retval);
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       *retval = &EG(uninitialized_zval);
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -25440,7 +27233,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_TMP(incdec_t in
                if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -25460,8 +27253,8 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_TMP(incdec_t in
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                        if (RETURN_VALUE_USED(opline)) {
-                               *retval = EG(uninitialized_zval_ptr);
-                               PZVAL_LOCK(*retval);
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               *retval = &EG(uninitialized_zval);
                        }
                }
        }
@@ -25472,6 +27265,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_TMP(incdec_t in
                zval_dtor(free_op2.var);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -25487,26 +27281,32 @@ static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDL
 
 static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_TMP(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
-       zval **object_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       zval **object_ptr;
        zval *object;
-       zval *property = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval *retval = &EX_T(opline->result.var).tmp_var;
+       zval *property;
+       zval *retval;
        int have_get_ptr = 0;
 
-       if (IS_CV == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+       property = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       retval = &EX_T(opline->result.var).tmp_var;
+
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                zval_dtor(free_op2.var);
-               *retval = *EG(uninitialized_zval_ptr);
+               ZVAL_NULL(retval);
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -25522,7 +27322,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_TMP(incdec_t i
                        have_get_ptr = 1;
                        SEPARATE_ZVAL_IF_NOT_REF(zptr);
 
-                       *retval = **zptr;
+                       ZVAL_COPY_VALUE(retval, *zptr);
                        zendi_zval_copy_ctor(*retval);
 
                        incdec_op(*zptr);
@@ -25535,7 +27335,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_TMP(incdec_t i
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
                        zval *z_copy;
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -25545,12 +27345,11 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_TMP(incdec_t i
                                }
                                z = value;
                        }
-                       *retval = *z;
+                       ZVAL_COPY_VALUE(retval, z);
                        zendi_zval_copy_ctor(*retval);
                        ALLOC_ZVAL(z_copy);
-                       *z_copy = *z;
+                       INIT_PZVAL_COPY(z_copy, z);
                        zendi_zval_copy_ctor(*z_copy);
-                       INIT_PZVAL(z_copy);
                        incdec_op(z_copy);
                        Z_ADDREF_P(z);
                        Z_OBJ_HT_P(object)->write_property(object, property, z_copy, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
@@ -25558,7 +27357,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_TMP(incdec_t i
                        zval_ptr_dtor(&z);
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-                       *retval = *EG(uninitialized_zval_ptr);
+                       ZVAL_NULL(retval);
                }
        }
 
@@ -25568,6 +27367,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_TMP(incdec_t i
                zval_dtor(free_op2.var);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -25583,194 +27383,193 @@ static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HAND
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
-       zval *dim = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
        zval **container;
 
+       SAVE_OPLINE();
+
        if ((opline->extended_value & ZEND_FETCH_ADD_LOCK) &&
            IS_CV != IS_CV &&
            EX_T(opline->op1.var).var.ptr_ptr) {
                PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
        }
-       container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
-       if (IS_CV == IS_VAR && !container) {
+       container = _get_zval_ptr_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address_read(!RETURN_VALUE_USED(opline)?NULL:&EX_T(opline->result.var), container, dim, IS_TMP_VAR, BP_VAR_R TSRMLS_CC);
+       zend_fetch_dimension_address_read(!RETURN_VALUE_USED(opline)?NULL:&EX_T(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_TMP_VAR, BP_VAR_R TSRMLS_CC);
        zval_dtor(free_op2.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *dim = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       zval **container;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && !container) {
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_TMP_VAR, BP_VAR_W TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_TMP_VAR, BP_VAR_W TSRMLS_CC);
        zval_dtor(free_op2.var);
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
        /* We are going to assign the result by reference */
-       if (opline->extended_value && EX_T(opline->result.var).var.ptr_ptr) {
-               Z_DELREF_PP(EX_T(opline->result.var).var.ptr_ptr);
-               SEPARATE_ZVAL_TO_MAKE_IS_REF(EX_T(opline->result.var).var.ptr_ptr);
-               Z_ADDREF_PP(EX_T(opline->result.var).var.ptr_ptr);
+       if (UNEXPECTED(opline->extended_value != 0)) {
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+
+               if (retval_ptr) {
+                       Z_DELREF_PP(retval_ptr);
+                       SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
+                       Z_ADDREF_PP(retval_ptr);
+               }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *dim = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_RW TSRMLS_CC);
+       zval **container;
 
-       if (IS_CV == IS_VAR && !container) {
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_RW(EX_CVs(), opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_TMP_VAR, BP_VAR_RW TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_TMP_VAR, BP_VAR_RW TSRMLS_CC);
        zval_dtor(free_op2.var);
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
-       zval *dim = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_IS TSRMLS_CC);
+       zval **container;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_IS(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && !container) {
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, dim, IS_TMP_VAR, BP_VAR_IS TSRMLS_CC);
+       zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_TMP_VAR, BP_VAR_IS TSRMLS_CC);
        zval_dtor(free_op2.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *dim = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
        zval **container;
 
+       SAVE_OPLINE();
+
        if (ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))) {
-               container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
-               if (IS_CV == IS_VAR && !container) {
+               container = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_TMP_VAR, BP_VAR_W TSRMLS_CC);
-               if (IS_CV == IS_VAR && 0 &&
-                   READY_TO_DESTROY(free_op1.var)) {
-                       AI_USE_PTR(EX_T(opline->result.var).var);
-                       if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                           Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                               SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-                       }
+               zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_TMP_VAR, BP_VAR_W TSRMLS_CC);
+               if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+                       EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
                }
        } else {
                if (IS_TMP_VAR == IS_UNUSED) {
                        zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
                }
-               container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
-               if (IS_CV == IS_VAR && !container) {
+               container = _get_zval_ptr_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, dim, IS_TMP_VAR, BP_VAR_R TSRMLS_CC);
+               zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_TMP_VAR, BP_VAR_R TSRMLS_CC);
        }
        zval_dtor(free_op2.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_UNSET_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_UNSET TSRMLS_CC);
-       zval *dim = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **container;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_UNSET(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       /* Not needed in DIM_UNSET
-       if (opline->extended_value & ZEND_FETCH_ADD_LOCK) {
-               PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
-       }
-       */
        if (IS_CV == IS_CV) {
                if (container != &EG(uninitialized_zval_ptr)) {
                        SEPARATE_ZVAL_IF_NOT_REF(container);
                }
        }
-       if (IS_CV == IS_VAR && !container) {
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_TMP_VAR, BP_VAR_UNSET TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_TMP_VAR, BP_VAR_UNSET TSRMLS_CC);
        zval_dtor(free_op2.var);
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
-       if (EX_T(opline->result.var).var.ptr_ptr == NULL) {
+       if (UNEXPECTED(EX_T(opline->result.var).var.ptr_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
        } else {
                zend_free_op free_res;
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
 
-               PZVAL_UNLOCK(*EX_T(opline->result.var).var.ptr_ptr, &free_res);
-               if (EX_T(opline->result.var).var.ptr_ptr != &EG(uninitialized_zval_ptr)) {
-                       SEPARATE_ZVAL_IF_NOT_REF(EX_T(opline->result.var).var.ptr_ptr);
+               PZVAL_UNLOCK(*retval_ptr, &free_res);
+               if (retval_ptr != &EG(uninitialized_zval_ptr)) {
+                       SEPARATE_ZVAL_IF_NOT_REF(retval_ptr);
                }
-               PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
+               PZVAL_LOCK(*retval_ptr);
                FREE_OP_VAR_PTR(free_res);
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
        }
-       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_CV_TMP(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_CV_TMP(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *container = _get_zval_ptr_cv(opline->op1.var, type TSRMLS_CC);
+       zval *container;
        zend_free_op free_op2;
-       zval *offset  = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval *offset;
 
-       if (Z_TYPE_P(container) != IS_OBJECT || !Z_OBJ_HT_P(container)->read_property) {
-               if (type != BP_VAR_IS) {
-                       zend_error(E_NOTICE, "Trying to get property of non-object");
-               }
+       SAVE_OPLINE();
+       container = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+       offset  = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               zend_error(E_NOTICE, "Trying to get property of non-object");
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
                zval_dtor(free_op2.var);
        } else {
@@ -25781,7 +27580,7 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_CV_TMP(int
                }
 
                /* here we are sure we are dealing with an object */
-               retval = Z_OBJ_HT_P(container)->read_property(container, offset, type, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
                if (!RETURN_VALUE_USED(opline)) {
                        if (Z_REFCOUNT_P(retval) == 0) {
@@ -25790,8 +27589,8 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_CV_TMP(int
                                FREE_ZVAL(retval);
                        }
                } else {
-                       AI_SET_PTR(EX_T(opline->result.var).var, retval);
                        PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                }
 
                if (1) {
@@ -25801,21 +27600,25 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_CV_TMP(int
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_property_address_read_helper_SPEC_CV_TMP(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_fetch_property_address_read_helper_SPEC_CV_TMP(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *property = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval *property;
        zval **container;
 
+       SAVE_OPLINE();
+       property = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
        if (IS_CV == IS_VAR && (opline->extended_value & ZEND_FETCH_ADD_LOCK)) {
                PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
                EX_T(opline->op1.var).var.ptr = *EX_T(opline->op1.var).var.ptr_ptr;
@@ -25824,46 +27627,49 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDL
        if (1) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
-       if (IS_CV == IS_VAR && !container) {
+       container = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
+
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
        if (1) {
                zval_ptr_dtor(&property);
        } else {
                zval_dtor(free_op2.var);
        }
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
        /* We are going to assign the result by reference */
        if (opline->extended_value & ZEND_FETCH_MAKE_REF) {
-               Z_DELREF_PP(EX_T(opline->result.var).var.ptr_ptr);
-               SEPARATE_ZVAL_TO_MAKE_IS_REF(EX_T(opline->result.var).var.ptr_ptr);
-               Z_ADDREF_PP(EX_T(opline->result.var).var.ptr_ptr);
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+
+               Z_DELREF_PP(retval_ptr);
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
+               Z_ADDREF_PP(retval_ptr);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *property = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_RW TSRMLS_CC);
+       zval *property;
+       zval **container;
+
+       SAVE_OPLINE();
+       property = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       container = _get_zval_ptr_ptr_cv_BP_VAR_RW(EX_CVs(), opline->op1.var TSRMLS_CC);
 
        if (1) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       if (IS_CV == IS_VAR && !container) {
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_RW TSRMLS_CC);
@@ -25872,37 +27678,83 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HAND
        } else {
                zval_dtor(free_op2.var);
        }
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_property_address_read_helper_SPEC_CV_TMP(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       USE_OPLINE
+
+       zval *container;
+       zend_free_op free_op2;
+       zval *offset;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_cv_BP_VAR_IS(EX_CVs(), opline->op1.var TSRMLS_CC);
+       offset  = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               if (RETURN_VALUE_USED(opline)) {
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+               }
+               zval_dtor(free_op2.var);
+       } else {
+               zval *retval;
+
+               if (1) {
+                       MAKE_REAL_ZVAL_PTR(offset);
+               }
+
+               /* here we are sure we are dealing with an object */
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+
+               if (!RETURN_VALUE_USED(opline)) {
+                       if (Z_REFCOUNT_P(retval) == 0) {
+                               GC_REMOVE_ZVAL_FROM_BUFFER(retval);
+                               zval_dtor(retval);
+                               FREE_ZVAL(retval);
+                       }
+               } else {
+                       PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
+               }
+
+               if (1) {
+                       zval_ptr_dtor(&offset);
+               } else {
+                       zval_dtor(free_op2.var);
+               }
+       }
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        if (ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))) {
                /* Behave like FETCH_OBJ_W */
                zend_free_op free_op1, free_op2;
-               zval *property = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-               zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+               zval *property;
+               zval **container;
+
+               SAVE_OPLINE();
+               property = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+               container = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
 
                if (1) {
                        MAKE_REAL_ZVAL_PTR(property);
                }
-               if (IS_CV == IS_VAR && !container) {
+               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
                }
                zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
@@ -25911,27 +27763,27 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_TMP_HANDLER(ZEND_OPCOD
                } else {
                        zval_dtor(free_op2.var);
                }
-               if (IS_CV == IS_VAR && 0 &&
-                   READY_TO_DESTROY(free_op1.var)) {
-                       AI_USE_PTR(EX_T(opline->result.var).var);
-                       if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                           Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                               SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-                       }
+               if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+                       EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
-               return zend_fetch_property_address_read_helper_SPEC_CV_TMP(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_fetch_property_address_read_helper_SPEC_CV_TMP(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2, free_res;
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
-       zval *property = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **container;
+       zval *property;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+       property = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
        if (IS_CV == IS_CV) {
                if (container != &EG(uninitialized_zval_ptr)) {
@@ -25941,7 +27793,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_H
        if (1) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       if (IS_CV == IS_VAR && !container) {
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_UNSET TSRMLS_CC);
@@ -25950,13 +27802,8 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_H
        } else {
                zval_dtor(free_op2.var);
        }
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
        PZVAL_UNLOCK(*EX_T(opline->result.var).var.ptr_ptr, &free_res);
@@ -25965,24 +27812,28 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_H
        }
        PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
        FREE_OP_VAR_PTR(free_res);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op2;
-       zval **object_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
-       zval *property_name = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **object_ptr;
+       zval *property_name;
+
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+       property_name = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
        if (1) {
                MAKE_REAL_ZVAL_PTR(property_name);
        }
-       if (IS_CV == IS_VAR && !object_ptr) {
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, op_data->op1_type, &op_data->op1, EX(Ts), ZEND_ASSIGN_OBJ, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), ZEND_ASSIGN_OBJ, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
        if (1) {
                zval_ptr_dtor(&property_name);
        } else {
@@ -25990,28 +27841,31 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLE
        }
 
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
 
-       zval **object_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       zval **object_ptr;
 
-       if (IS_CV == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
        if (Z_TYPE_PP(object_ptr) == IS_OBJECT) {
                zend_free_op free_op2;
-               zval *property_name = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+               zval *property_name = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
                if (1) {
                        MAKE_REAL_ZVAL_PTR(property_name);
                }
-               zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, op_data->op1_type, &op_data->op1, EX(Ts), ZEND_ASSIGN_DIM, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+               zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), ZEND_ASSIGN_DIM, ((IS_TMP_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
                if (1) {
                        zval_ptr_dtor(&property_name);
                } else {
@@ -26020,31 +27874,45 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLE
        } else {
                zend_free_op free_op2, free_op_data1, free_op_data2;
                zval *value;
-               zval *dim = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+               zval *dim = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
                zval **variable_ptr_ptr;
 
-               zend_fetch_dimension_address(&EX_T(op_data->op2.var), object_ptr, dim, IS_TMP_VAR, BP_VAR_W TSRMLS_CC);
+               zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), object_ptr, dim, IS_TMP_VAR, BP_VAR_W TSRMLS_CC);
                zval_dtor(free_op2.var);
 
-               value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-               variable_ptr_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-               if (!variable_ptr_ptr) {
-                       if (zend_assign_to_string_offset(&EX_T(op_data->op2.var), value, op_data->op1_type TSRMLS_CC)) {
+               value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+               variable_ptr_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
+               if (UNEXPECTED(variable_ptr_ptr == NULL)) {
+                       if (zend_assign_to_string_offset(&EX_T((opline+1)->op2.var), value, (opline+1)->op1_type TSRMLS_CC)) {
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-                                       ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                                       INIT_PZVAL(EX_T(opline->result.var).var.ptr);
-                                       ZVAL_STRINGL(EX_T(opline->result.var).var.ptr, Z_STRVAL_P(EX_T(op_data->op2.var).str_offset.str)+EX_T(op_data->op2.var).str_offset.offset, 1, 1);
+                                       zval *retval;
+
+                                       ALLOC_ZVAL(retval);
+                                       ZVAL_STRINGL(retval, Z_STRVAL_P(EX_T((opline+1)->op2.var).str_offset.str)+EX_T((opline+1)->op2.var).str_offset.offset, 1, 1);
+                                       INIT_PZVAL(retval);
+                                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                                }
                        } else if (RETURN_VALUE_USED(opline)) {
-                               AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                               PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+                       }
+               } else if (UNEXPECTED(*variable_ptr_ptr == &EG(error_zval))) {
+                       if (IS_TMP_FREE(free_op_data1)) {
+                               zval_dtor(value);
+                       }
+                       if (RETURN_VALUE_USED(opline)) {
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                        }
                } else {
-                       value = zend_assign_to_variable(variable_ptr_ptr, value, IS_TMP_FREE(free_op_data1) TSRMLS_CC);
+                       if (IS_TMP_FREE(free_op_data1)) {
+                               value = zend_assign_tmp_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+                       } else {
+                               value = zend_assign_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+                       }
                        if (RETURN_VALUE_USED(opline)) {
-                               AI_SET_PTR(EX_T(opline->result.var).var, value);
                                PZVAL_LOCK(value);
+                               AI_SET_PTR(&EX_T(opline->result.var), value);
                        }
                }
                FREE_OP_VAR_PTR(free_op_data2);
@@ -26052,71 +27920,94 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLE
        }
 
        /* assign_dim has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
-       zval *value = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **variable_ptr_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       zval *value;
+       zval **variable_ptr_ptr;
+
+       SAVE_OPLINE();
+       value = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       variable_ptr_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && !variable_ptr_ptr) {
+       if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr_ptr == NULL)) {
                if (zend_assign_to_string_offset(&EX_T(opline->op1.var), value, IS_TMP_VAR TSRMLS_CC)) {
                        if (RETURN_VALUE_USED(opline)) {
-                               EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-                               ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                               INIT_PZVAL(EX_T(opline->result.var).var.ptr);
-                               ZVAL_STRINGL(EX_T(opline->result.var).var.ptr, Z_STRVAL_P(EX_T(opline->op1.var).str_offset.str)+EX_T(opline->op1.var).str_offset.offset, 1, 1);
+                               zval *retval;
+
+                               ALLOC_ZVAL(retval);
+                               ZVAL_STRINGL(retval, Z_STRVAL_P(EX_T(opline->op1.var).str_offset.str)+EX_T(opline->op1.var).str_offset.offset, 1, 1);
+                               INIT_PZVAL(retval);
+                               AI_SET_PTR(&EX_T(opline->result.var), retval);
                        }
                } else if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+               }
+       } else if (IS_CV == IS_VAR && UNEXPECTED(*variable_ptr_ptr == &EG(error_zval))) {
+               if (1) {
+                       zval_dtor(value);
+               }
+               if (RETURN_VALUE_USED(opline)) {
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
        } else {
-               value = zend_assign_to_variable(variable_ptr_ptr, value, 1 TSRMLS_CC);
+               if (1) {
+                       value = zend_assign_tmp_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+               } else {
+                       value = zend_assign_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+               }
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, value);
                        PZVAL_LOCK(value);
+                       AI_SET_PTR(&EX_T(opline->result.var), value);
                }
        }
 
        /* zend_assign_to_variable() always takes care of op2, never free it! */
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        char *function_name_strval;
        int function_name_strlen;
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
-       function_name = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       function_name = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
-       if (Z_TYPE_P(function_name)!=IS_STRING) {
+       if (IS_TMP_VAR != IS_CONST &&
+           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                zend_error_noreturn(E_ERROR, "Method name must be a string");
        }
 
        function_name_strval = Z_STRVAL_P(function_name);
        function_name_strlen = Z_STRLEN_P(function_name);
 
-       EX(object) = _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+       EX(object) = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       if (EX(object) && Z_TYPE_P(EX(object)) == IS_OBJECT) {
-               if (Z_OBJ_HT_P(EX(object))->get_method == NULL) {
+       if (EXPECTED(EX(object) != NULL) &&
+           EXPECTED(Z_TYPE_P(EX(object)) == IS_OBJECT)) {
+               if (UNEXPECTED(Z_OBJ_HT_P(EX(object))->get_method == NULL)) {
                        zend_error_noreturn(E_ERROR, "Object does not support method calls");
                }
 
                /* First, locate the function. */
                EX(fbc) = Z_OBJ_HT_P(EX(object))->get_method(&EX(object), function_name_strval, function_name_strlen, ((IS_TMP_VAR == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
-               if (!EX(fbc)) {
+               if (UNEXPECTED(EX(fbc) == NULL)) {
                        zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", Z_OBJ_CLASS_NAME_P(EX(object)), function_name_strval);
                }
 
@@ -26141,15 +28032,17 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_
 
        zval_dtor(free_op2.var);
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CASE_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        int switch_expr_is_overloaded=0;
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        if (IS_CV==IS_VAR) {
                if (EX_T(opline->op1.var).var.ptr_ptr) {
                        PZVAL_LOCK(EX_T(opline->op1.var).var.ptr);
@@ -26159,8 +28052,8 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS
                }
        }
        is_equal_function(&EX_T(opline->result.var).tmp_var,
-                                _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-                                _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+                                _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+                                _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        zval_dtor(free_op2.var);
        if (switch_expr_is_overloaded) {
@@ -26173,47 +28066,32 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS
                EX_T(opline->op1.var).var.ptr_ptr = NULL;
                EX_T(opline->op1.var).var.ptr = NULL;
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_free_op free_op2;
-       zval *array_ptr = &EX_T(opline->result.var).tmp_var;
+       USE_OPLINE
+
        zval *expr_ptr;
-       zval *offset=_get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       ulong hval;
-       long index;
 
-#if 0 || IS_CV == IS_VAR || IS_CV == IS_CV
-       zval **expr_ptr_ptr = NULL;
+       SAVE_OPLINE();
+       if ((IS_CV == IS_VAR || IS_CV == IS_CV) && opline->extended_value) {
+               zval **expr_ptr_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       if (opline->extended_value) {
-               expr_ptr_ptr=_get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
                expr_ptr = *expr_ptr_ptr;
+               Z_ADDREF_P(expr_ptr);
        } else {
-               expr_ptr=_get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
-       }
-#else
-       expr_ptr=_get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
-#endif
-
-       if (0) { /* temporary variable */
-               zval *new_expr;
+               expr_ptr=_get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+               if (0) { /* temporary variable */
+                       zval *new_expr;
 
-               ALLOC_ZVAL(new_expr);
-               INIT_PZVAL_COPY(new_expr, expr_ptr);
-               expr_ptr = new_expr;
-       } else {
-#if 0 || IS_CV == IS_VAR || IS_CV == IS_CV
-               if (opline->extended_value) {
-                       SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
-                       expr_ptr = *expr_ptr_ptr;
-                       Z_ADDREF_P(expr_ptr);
-               } else
-#endif
-               if (IS_CV == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
+                       ALLOC_ZVAL(new_expr);
+                       INIT_PZVAL_COPY(new_expr, expr_ptr);
+                       expr_ptr = new_expr;
+               } else if (IS_CV == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
                        zval *new_expr;
 
                        ALLOC_ZVAL(new_expr);
@@ -26224,7 +28102,13 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_TMP_HANDLER(ZEND_OPCODE
                        Z_ADDREF_P(expr_ptr);
                }
        }
-       if (offset) {
+
+       if (IS_TMP_VAR != IS_UNUSED) {
+               zend_free_op free_op2;
+               zval *offset = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+               ulong hval;
+               long index;
+
                switch (Z_TYPE_P(offset)) {
                        case IS_DOUBLE:
                                index = zend_dval_to_lval(Z_DVAL_P(offset));
@@ -26233,7 +28117,7 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_TMP_HANDLER(ZEND_OPCODE
                        case IS_BOOL:
                                index = Z_LVAL_P(offset);
 num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(array_ptr), index, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_index_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), index, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_STRING:
                                if (IS_TMP_VAR == IS_CONST) {
@@ -26246,10 +28130,10 @@ num_index:
                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                        }
                                }
-                               zend_hash_quick_update(Z_ARRVAL_P(array_ptr), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_quick_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_NULL:
-                               zend_hash_update(Z_ARRVAL_P(array_ptr), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
                                break;
                        default:
                                zend_error(E_WARNING, "Illegal offset type");
@@ -26259,19 +28143,20 @@ num_index:
                }
                zval_dtor(free_op2.var);
        } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(array_ptr), &expr_ptr, sizeof(zval *), NULL);
+               zend_hash_next_index_insert(Z_ARRVAL(EX_T(opline->result.var).tmp_var), &expr_ptr, sizeof(zval *), NULL);
        }
-       if (opline->extended_value) {
+       if ((IS_CV == IS_VAR || IS_CV == IS_CV) && opline->extended_value) {
 
        } else {
 
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (IS_CV == IS_UNUSED) {
@@ -26285,13 +28170,17 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLE
 
 static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_UNSET TSRMLS_CC);
-       zval *offset = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **container;
+       zval *offset;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_UNSET(EX_CVs(), opline->op1.var TSRMLS_CC);
+       offset = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
        if (IS_CV != IS_VAR || container) {
                if (IS_CV == IS_CV && container != &EG(uninitialized_zval_ptr)) {
                        SEPARATE_ZVAL_IF_NOT_REF(container);
@@ -26325,24 +28214,10 @@ num_index_dim:
                                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                                        }
                                                }
-                                               if (zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval) == SUCCESS &&
-                                           ht == &EG(symbol_table)) {
-                                                       zend_execute_data *ex;
-
-                                                       for (ex = execute_data; ex; ex = ex->prev_execute_data) {
-                                                               if (ex->op_array && ex->symbol_table == ht) {
-                                                                       int i;
-
-                                                                       for (i = 0; i < ex->op_array->last_var; i++) {
-                                                                               if (ex->op_array->vars[i].hash_value == hval &&
-                                                                                   ex->op_array->vars[i].name_len == offset->value.str.len &&
-                                                                                   !memcmp(ex->op_array->vars[i].name, offset->value.str.val, offset->value.str.len)) {
-                                                                                       ex->CVs[i] = NULL;
-                                                                                       break;
-                                                                               }
-                                                                       }
-                                                               }
-                                                       }
+                                               if (ht == &EG(symbol_table)) {
+                                                       zend_delete_global_variable_ex(offset->value.str.val, offset->value.str.len, hval TSRMLS_CC);
+                                               } else {
+                                                       zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval);
                                                }
                                                if (IS_TMP_VAR == IS_CV || IS_TMP_VAR == IS_VAR) {
                                                        zval_ptr_dtor(&offset);
@@ -26359,7 +28234,7 @@ num_index_dim:
                                break;
                        }
                        case IS_OBJECT:
-                               if (!Z_OBJ_HT_P(*container)->unset_dimension) {
+                               if (UNEXPECTED(Z_OBJ_HT_P(*container)->unset_dimension == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use object as array");
                                }
                                if (1) {
@@ -26383,15 +28258,20 @@ num_index_dim:
                zval_dtor(free_op2.var);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_UNSET TSRMLS_CC);
-       zval *offset = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **container;
+       zval *offset;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_UNSET(EX_CVs(), opline->op1.var TSRMLS_CC);
+       offset = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
        if (IS_CV != IS_VAR || container) {
                if (IS_CV == IS_CV && container != &EG(uninitialized_zval_ptr)) {
@@ -26418,22 +28298,26 @@ static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_CV_TMP_HANDLER(ZEND_OPCODE_HANDLER
                zval_dtor(free_op2.var);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_isset_isempty_dim_prop_obj_handler_SPEC_CV_TMP(int prop_dim, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_IS TSRMLS_CC);
+       zval **container;
        zval **value = NULL;
        int result = 0;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_IS(EX_CVs(), opline->op1.var TSRMLS_CC);
+
        if (IS_CV != IS_VAR || container) {
                zend_free_op free_op2;
-               zval *offset = _get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+               zval *offset = _get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
                if (Z_TYPE_PP(container) == IS_ARRAY && !prop_dim) {
                        HashTable *ht;
@@ -26524,7 +28408,7 @@ num_index_prop:
                        zval tmp;
 
                        if (Z_TYPE_P(offset) != IS_LONG) {
-                               tmp = *offset;
+                               ZVAL_COPY_VALUE(&tmp, offset);
                                zval_copy_ctor(&tmp);
                                convert_to_long(&tmp);
                                offset = &tmp;
@@ -26547,13 +28431,13 @@ num_index_prop:
        }
 
        Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
-
        if (opline->extended_value & ZEND_ISSET) {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = result;
-       } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+       } else {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = !result;
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -26569,277 +28453,311 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_TMP_HANDLER(ZEND_O
 
 static int ZEND_FASTCALL  ZEND_ADD_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        add_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SUB_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        sub_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MUL_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        mul_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_DIV_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        div_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MOD_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        mod_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SL_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        shift_left_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        shift_right_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        concat_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        is_identical_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        is_identical_function(result,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        Z_LVAL_P(result) = !Z_LVAL_P(result);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) == 0));
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) != 0));
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) < 0));
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) <= 0));
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        bitwise_or_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        bitwise_and_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        bitwise_xor_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        boolean_xor_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op2, free_op_data1;
-       zval **object_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       zval **object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
        zval *object;
-       zval *property = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval *value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
+       zval *property = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       zval *value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
        znode_op *result = &opline->result;
        int have_get_ptr = 0;
 
-       if (IS_CV == IS_VAR && !object_ptr) {
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
 
-       EX_T(result->var).var.ptr_ptr = NULL;
        make_real_object(object_ptr TSRMLS_CC);
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to assign property of non-object");
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
                FREE_OP(free_op_data1);
 
                if (RETURN_VALUE_USED(opline)) {
-                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                       EX_T(result->var).var.ptr_ptr = NULL;
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                }
        } else {
                /* here we are sure we are dealing with an object */
@@ -26857,9 +28775,9 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_VAR(int (*bina
                                have_get_ptr = 1;
                                binary_op(*zptr, *zptr, value TSRMLS_CC);
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = *zptr;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(*zptr);
+                                       EX_T(opline->result.var).var.ptr = *zptr;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -26896,17 +28814,17 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_VAR(int (*bina
                                        Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
                                }
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = z;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(z);
+                                       EX_T(opline->result.var).var.ptr = z;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                                zval_ptr_dtor(&z);
                        } else {
                                zend_error(E_WARNING, "Attempt to assign property of non-object");
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                                       EX_T(result->var).var.ptr_ptr = NULL;
-                                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                                       PZVAL_LOCK(&EG(uninitialized_zval));
+                                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -26920,66 +28838,71 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_VAR(int (*bina
        }
 
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_VAR(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2, free_op_data2, free_op_data1;
        zval **var_ptr;
        zval *value;
 
+       SAVE_OPLINE();
        switch (opline->extended_value) {
                case ZEND_ASSIGN_OBJ:
                        return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                        break;
                case ZEND_ASSIGN_DIM: {
-                               zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_RW TSRMLS_CC);
+                               zval **container = _get_zval_ptr_ptr_cv_BP_VAR_RW(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-                               if (IS_CV == IS_VAR && !container) {
+                               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-                               } else if (Z_TYPE_PP(container) == IS_OBJECT) {
+                               } else if (UNEXPECTED(Z_TYPE_PP(container) == IS_OBJECT)) {
                                        if (IS_CV == IS_VAR && !0) {
                                                Z_ADDREF_PP(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
                                        }
                                        return zend_binary_assign_op_obj_helper_SPEC_CV_VAR(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                                } else {
-                                       zend_op *op_data = opline+1;
-                                       zval *dim = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+                                       zval *dim = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
-                                       zend_fetch_dimension_address(&EX_T(op_data->op2.var), container, dim, IS_VAR, BP_VAR_RW TSRMLS_CC);
-                                       value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-                                       var_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-                                       ZEND_VM_INC_OPCODE();
+                                       zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), container, dim, IS_VAR, BP_VAR_RW TSRMLS_CC);
+                                       value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+                                       var_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
                                }
                        }
                        break;
                default:
-                       value = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-                       var_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_RW TSRMLS_CC);
+                       value = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+                       var_ptr = _get_zval_ptr_ptr_cv_BP_VAR_RW(EX_CVs(), opline->op1.var TSRMLS_CC);
                        /* do nothing */
                        break;
        }
 
-       if (!var_ptr) {
+       if (UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
        }
 
-       if (*var_ptr == EG(error_zval_ptr)) {
+       if (UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
 
+               CHECK_EXCEPTION();
+               if (opline->extended_value == ZEND_ASSIGN_DIM) {
+                       ZEND_VM_INC_OPCODE();
+               }
                ZEND_VM_NEXT_OPCODE();
        }
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *objval = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -26992,16 +28915,21 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_VAR(int (*binary_o
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *var_ptr);
                PZVAL_LOCK(*var_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *var_ptr);
        }
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
 
        if (opline->extended_value == ZEND_ASSIGN_DIM) {
                FREE_OP(free_op_data1);
                FREE_OP_VAR_PTR(free_op_data2);
-       }
 
+               CHECK_EXCEPTION();
+               ZEND_VM_INC_OPCODE();
+       } else {
+
+               CHECK_EXCEPTION();
+       }
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -27062,29 +28990,35 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HAN
 
 static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_VAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
-       zval **object_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       zval **object_ptr;
        zval *object;
-       zval *property = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **retval = &EX_T(opline->result.var).var.ptr;
+       zval *property;
+       zval **retval;
        int have_get_ptr = 0;
 
-       if (IS_CV == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+       property = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       retval = &EX_T(opline->result.var).var.ptr;
+
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
                if (RETURN_VALUE_USED(opline)) {
-                       *retval = EG(uninitialized_zval_ptr);
-                       PZVAL_LOCK(*retval);
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       *retval = &EG(uninitialized_zval);
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -27112,7 +29046,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_VAR(incdec_t in
                if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -27132,8 +29066,8 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_VAR(incdec_t in
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                        if (RETURN_VALUE_USED(opline)) {
-                               *retval = EG(uninitialized_zval_ptr);
-                               PZVAL_LOCK(*retval);
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               *retval = &EG(uninitialized_zval);
                        }
                }
        }
@@ -27144,6 +29078,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_VAR(incdec_t in
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -27159,26 +29094,32 @@ static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDL
 
 static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_VAR(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
-       zval **object_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       zval **object_ptr;
        zval *object;
-       zval *property = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval *retval = &EX_T(opline->result.var).tmp_var;
+       zval *property;
+       zval *retval;
        int have_get_ptr = 0;
 
-       if (IS_CV == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+       property = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       retval = &EX_T(opline->result.var).tmp_var;
+
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
-               *retval = *EG(uninitialized_zval_ptr);
+               ZVAL_NULL(retval);
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -27194,7 +29135,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_VAR(incdec_t i
                        have_get_ptr = 1;
                        SEPARATE_ZVAL_IF_NOT_REF(zptr);
 
-                       *retval = **zptr;
+                       ZVAL_COPY_VALUE(retval, *zptr);
                        zendi_zval_copy_ctor(*retval);
 
                        incdec_op(*zptr);
@@ -27207,7 +29148,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_VAR(incdec_t i
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
                        zval *z_copy;
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -27217,12 +29158,11 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_VAR(incdec_t i
                                }
                                z = value;
                        }
-                       *retval = *z;
+                       ZVAL_COPY_VALUE(retval, z);
                        zendi_zval_copy_ctor(*retval);
                        ALLOC_ZVAL(z_copy);
-                       *z_copy = *z;
+                       INIT_PZVAL_COPY(z_copy, z);
                        zendi_zval_copy_ctor(*z_copy);
-                       INIT_PZVAL(z_copy);
                        incdec_op(z_copy);
                        Z_ADDREF_P(z);
                        Z_OBJ_HT_P(object)->write_property(object, property, z_copy, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
@@ -27230,7 +29170,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_VAR(incdec_t i
                        zval_ptr_dtor(&z);
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-                       *retval = *EG(uninitialized_zval_ptr);
+                       ZVAL_NULL(retval);
                }
        }
 
@@ -27240,6 +29180,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_VAR(incdec_t i
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -27255,194 +29196,193 @@ static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HAND
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
-       zval *dim = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
        zval **container;
 
+       SAVE_OPLINE();
+
        if ((opline->extended_value & ZEND_FETCH_ADD_LOCK) &&
            IS_CV != IS_CV &&
            EX_T(opline->op1.var).var.ptr_ptr) {
                PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
        }
-       container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
-       if (IS_CV == IS_VAR && !container) {
+       container = _get_zval_ptr_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address_read(!RETURN_VALUE_USED(opline)?NULL:&EX_T(opline->result.var), container, dim, IS_VAR, BP_VAR_R TSRMLS_CC);
+       zend_fetch_dimension_address_read(!RETURN_VALUE_USED(opline)?NULL:&EX_T(opline->result.var), container, _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_VAR, BP_VAR_R TSRMLS_CC);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *dim = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       zval **container;
 
-       if (IS_CV == IS_VAR && !container) {
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_VAR, BP_VAR_W TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_VAR, BP_VAR_W TSRMLS_CC);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
        /* We are going to assign the result by reference */
-       if (opline->extended_value && EX_T(opline->result.var).var.ptr_ptr) {
-               Z_DELREF_PP(EX_T(opline->result.var).var.ptr_ptr);
-               SEPARATE_ZVAL_TO_MAKE_IS_REF(EX_T(opline->result.var).var.ptr_ptr);
-               Z_ADDREF_PP(EX_T(opline->result.var).var.ptr_ptr);
+       if (UNEXPECTED(opline->extended_value != 0)) {
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+
+               if (retval_ptr) {
+                       Z_DELREF_PP(retval_ptr);
+                       SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
+                       Z_ADDREF_PP(retval_ptr);
+               }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *dim = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_RW TSRMLS_CC);
+       zval **container;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_RW(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && !container) {
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_VAR, BP_VAR_RW TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_VAR, BP_VAR_RW TSRMLS_CC);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
-       zval *dim = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_IS TSRMLS_CC);
+       zval **container;
 
-       if (IS_CV == IS_VAR && !container) {
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_IS(EX_CVs(), opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, dim, IS_VAR, BP_VAR_IS TSRMLS_CC);
+       zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_VAR, BP_VAR_IS TSRMLS_CC);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *dim = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
        zval **container;
 
+       SAVE_OPLINE();
+
        if (ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))) {
-               container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
-               if (IS_CV == IS_VAR && !container) {
+               container = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_VAR, BP_VAR_W TSRMLS_CC);
-               if (IS_CV == IS_VAR && 0 &&
-                   READY_TO_DESTROY(free_op1.var)) {
-                       AI_USE_PTR(EX_T(opline->result.var).var);
-                       if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                           Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                               SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-                       }
+               zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_VAR, BP_VAR_W TSRMLS_CC);
+               if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+                       EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
                }
        } else {
                if (IS_VAR == IS_UNUSED) {
                        zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
                }
-               container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
-               if (IS_CV == IS_VAR && !container) {
+               container = _get_zval_ptr_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, dim, IS_VAR, BP_VAR_R TSRMLS_CC);
+               zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_VAR, BP_VAR_R TSRMLS_CC);
        }
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_UNSET_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_UNSET TSRMLS_CC);
-       zval *dim = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **container;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_UNSET(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       /* Not needed in DIM_UNSET
-       if (opline->extended_value & ZEND_FETCH_ADD_LOCK) {
-               PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
-       }
-       */
        if (IS_CV == IS_CV) {
                if (container != &EG(uninitialized_zval_ptr)) {
                        SEPARATE_ZVAL_IF_NOT_REF(container);
                }
        }
-       if (IS_CV == IS_VAR && !container) {
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_VAR, BP_VAR_UNSET TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC), IS_VAR, BP_VAR_UNSET TSRMLS_CC);
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
-       if (EX_T(opline->result.var).var.ptr_ptr == NULL) {
+       if (UNEXPECTED(EX_T(opline->result.var).var.ptr_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
        } else {
                zend_free_op free_res;
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
 
-               PZVAL_UNLOCK(*EX_T(opline->result.var).var.ptr_ptr, &free_res);
-               if (EX_T(opline->result.var).var.ptr_ptr != &EG(uninitialized_zval_ptr)) {
-                       SEPARATE_ZVAL_IF_NOT_REF(EX_T(opline->result.var).var.ptr_ptr);
+               PZVAL_UNLOCK(*retval_ptr, &free_res);
+               if (retval_ptr != &EG(uninitialized_zval_ptr)) {
+                       SEPARATE_ZVAL_IF_NOT_REF(retval_ptr);
                }
-               PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
+               PZVAL_LOCK(*retval_ptr);
                FREE_OP_VAR_PTR(free_res);
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
        }
-       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_CV_VAR(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_CV_VAR(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *container = _get_zval_ptr_cv(opline->op1.var, type TSRMLS_CC);
+       zval *container;
        zend_free_op free_op2;
-       zval *offset  = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval *offset;
 
-       if (Z_TYPE_P(container) != IS_OBJECT || !Z_OBJ_HT_P(container)->read_property) {
-               if (type != BP_VAR_IS) {
-                       zend_error(E_NOTICE, "Trying to get property of non-object");
-               }
+       SAVE_OPLINE();
+       container = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+       offset  = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               zend_error(E_NOTICE, "Trying to get property of non-object");
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        } else {
@@ -27453,7 +29393,7 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_CV_VAR(int
                }
 
                /* here we are sure we are dealing with an object */
-               retval = Z_OBJ_HT_P(container)->read_property(container, offset, type, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
                if (!RETURN_VALUE_USED(opline)) {
                        if (Z_REFCOUNT_P(retval) == 0) {
@@ -27462,8 +29402,8 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_CV_VAR(int
                                FREE_ZVAL(retval);
                        }
                } else {
-                       AI_SET_PTR(EX_T(opline->result.var).var, retval);
                        PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                }
 
                if (0) {
@@ -27473,21 +29413,25 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_CV_VAR(int
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_property_address_read_helper_SPEC_CV_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_fetch_property_address_read_helper_SPEC_CV_VAR(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2;
-       zval *property = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval *property;
        zval **container;
 
+       SAVE_OPLINE();
+       property = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
        if (IS_CV == IS_VAR && (opline->extended_value & ZEND_FETCH_ADD_LOCK)) {
                PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
                EX_T(opline->op1.var).var.ptr = *EX_T(opline->op1.var).var.ptr_ptr;
@@ -27496,85 +29440,134 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDL
        if (0) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
-       if (IS_CV == IS_VAR && !container) {
+       container = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
+
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
        if (0) {
                zval_ptr_dtor(&property);
        } else {
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        }
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
        /* We are going to assign the result by reference */
        if (opline->extended_value & ZEND_FETCH_MAKE_REF) {
-               Z_DELREF_PP(EX_T(opline->result.var).var.ptr_ptr);
-               SEPARATE_ZVAL_TO_MAKE_IS_REF(EX_T(opline->result.var).var.ptr_ptr);
-               Z_ADDREF_PP(EX_T(opline->result.var).var.ptr_ptr);
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+
+               Z_DELREF_PP(retval_ptr);
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
+               Z_ADDREF_PP(retval_ptr);
+       }
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
+}
+
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+       zend_free_op free_op1, free_op2;
+       zval *property;
+       zval **container;
+
+       SAVE_OPLINE();
+       property = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       container = _get_zval_ptr_ptr_cv_BP_VAR_RW(EX_CVs(), opline->op1.var TSRMLS_CC);
+
+       if (0) {
+               MAKE_REAL_ZVAL_PTR(property);
+       }
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
+               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
+       }
+       zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_RW TSRMLS_CC);
+       if (0) {
+               zval_ptr_dtor(&property);
+       } else {
+               if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       zend_op *opline = EX(opline);
-       zend_free_op free_op1, free_op2;
-       zval *property = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_RW TSRMLS_CC);
+static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
+{
+       USE_OPLINE
+
+       zval *container;
+       zend_free_op free_op2;
+       zval *offset;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_cv_BP_VAR_IS(EX_CVs(), opline->op1.var TSRMLS_CC);
+       offset  = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               if (RETURN_VALUE_USED(opline)) {
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+               }
+               if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
+       } else {
+               zval *retval;
+
+               if (0) {
+                       MAKE_REAL_ZVAL_PTR(offset);
+               }
+
+               /* here we are sure we are dealing with an object */
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+
+               if (!RETURN_VALUE_USED(opline)) {
+                       if (Z_REFCOUNT_P(retval) == 0) {
+                               GC_REMOVE_ZVAL_FROM_BUFFER(retval);
+                               zval_dtor(retval);
+                               FREE_ZVAL(retval);
+                       }
+               } else {
+                       PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
+               }
 
-       if (0) {
-               MAKE_REAL_ZVAL_PTR(property);
-       }
-       if (IS_CV == IS_VAR && !container) {
-               zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
-       }
-       zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_RW TSRMLS_CC);
-       if (0) {
-               zval_ptr_dtor(&property);
-       } else {
-               if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
-       }
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
+               if (0) {
+                       zval_ptr_dtor(&offset);
+               } else {
+                       if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
-{
-       return zend_fetch_property_address_read_helper_SPEC_CV_VAR(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
-}
-
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        if (ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))) {
                /* Behave like FETCH_OBJ_W */
                zend_free_op free_op1, free_op2;
-               zval *property = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-               zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+               zval *property;
+               zval **container;
+
+               SAVE_OPLINE();
+               property = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+               container = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
 
                if (0) {
                        MAKE_REAL_ZVAL_PTR(property);
                }
-               if (IS_CV == IS_VAR && !container) {
+               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
                }
                zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
@@ -27583,27 +29576,27 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_VAR_HANDLER(ZEND_OPCOD
                } else {
                        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
                }
-               if (IS_CV == IS_VAR && 0 &&
-                   READY_TO_DESTROY(free_op1.var)) {
-                       AI_USE_PTR(EX_T(opline->result.var).var);
-                       if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                           Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                               SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-                       }
+               if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+                       EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
-               return zend_fetch_property_address_read_helper_SPEC_CV_VAR(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_fetch_property_address_read_helper_SPEC_CV_VAR(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_op2, free_res;
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
-       zval *property = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **container;
+       zval *property;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+       property = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
        if (IS_CV == IS_CV) {
                if (container != &EG(uninitialized_zval_ptr)) {
@@ -27613,7 +29606,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_H
        if (0) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       if (IS_CV == IS_VAR && !container) {
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_UNSET TSRMLS_CC);
@@ -27622,13 +29615,8 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_H
        } else {
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        }
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
        PZVAL_UNLOCK(*EX_T(opline->result.var).var.ptr_ptr, &free_res);
@@ -27637,24 +29625,28 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_H
        }
        PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
        FREE_OP_VAR_PTR(free_res);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op2;
-       zval **object_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
-       zval *property_name = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **object_ptr;
+       zval *property_name;
+
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+       property_name = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
        if (0) {
                MAKE_REAL_ZVAL_PTR(property_name);
        }
-       if (IS_CV == IS_VAR && !object_ptr) {
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, op_data->op1_type, &op_data->op1, EX(Ts), ZEND_ASSIGN_OBJ, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), ZEND_ASSIGN_OBJ, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
        if (0) {
                zval_ptr_dtor(&property_name);
        } else {
@@ -27662,28 +29654,31 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLE
        }
 
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
+
+       zval **object_ptr;
 
-       zval **object_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && !object_ptr) {
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
        if (Z_TYPE_PP(object_ptr) == IS_OBJECT) {
                zend_free_op free_op2;
-               zval *property_name = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+               zval *property_name = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
                if (0) {
                        MAKE_REAL_ZVAL_PTR(property_name);
                }
-               zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, op_data->op1_type, &op_data->op1, EX(Ts), ZEND_ASSIGN_DIM, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+               zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), ZEND_ASSIGN_DIM, ((IS_VAR == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
                if (0) {
                        zval_ptr_dtor(&property_name);
                } else {
@@ -27692,31 +29687,45 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLE
        } else {
                zend_free_op free_op2, free_op_data1, free_op_data2;
                zval *value;
-               zval *dim = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+               zval *dim = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
                zval **variable_ptr_ptr;
 
-               zend_fetch_dimension_address(&EX_T(op_data->op2.var), object_ptr, dim, IS_VAR, BP_VAR_W TSRMLS_CC);
+               zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), object_ptr, dim, IS_VAR, BP_VAR_W TSRMLS_CC);
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
 
-               value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-               variable_ptr_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-               if (!variable_ptr_ptr) {
-                       if (zend_assign_to_string_offset(&EX_T(op_data->op2.var), value, op_data->op1_type TSRMLS_CC)) {
+               value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+               variable_ptr_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
+               if (UNEXPECTED(variable_ptr_ptr == NULL)) {
+                       if (zend_assign_to_string_offset(&EX_T((opline+1)->op2.var), value, (opline+1)->op1_type TSRMLS_CC)) {
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-                                       ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                                       INIT_PZVAL(EX_T(opline->result.var).var.ptr);
-                                       ZVAL_STRINGL(EX_T(opline->result.var).var.ptr, Z_STRVAL_P(EX_T(op_data->op2.var).str_offset.str)+EX_T(op_data->op2.var).str_offset.offset, 1, 1);
+                                       zval *retval;
+
+                                       ALLOC_ZVAL(retval);
+                                       ZVAL_STRINGL(retval, Z_STRVAL_P(EX_T((opline+1)->op2.var).str_offset.str)+EX_T((opline+1)->op2.var).str_offset.offset, 1, 1);
+                                       INIT_PZVAL(retval);
+                                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                                }
                        } else if (RETURN_VALUE_USED(opline)) {
-                               AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                               PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+                       }
+               } else if (UNEXPECTED(*variable_ptr_ptr == &EG(error_zval))) {
+                       if (IS_TMP_FREE(free_op_data1)) {
+                               zval_dtor(value);
+                       }
+                       if (RETURN_VALUE_USED(opline)) {
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                        }
                } else {
-                       value = zend_assign_to_variable(variable_ptr_ptr, value, IS_TMP_FREE(free_op_data1) TSRMLS_CC);
+                       if (IS_TMP_FREE(free_op_data1)) {
+                               value = zend_assign_tmp_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+                       } else {
+                               value = zend_assign_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+                       }
                        if (RETURN_VALUE_USED(opline)) {
-                               AI_SET_PTR(EX_T(opline->result.var).var, value);
                                PZVAL_LOCK(value);
+                               AI_SET_PTR(&EX_T(opline->result.var), value);
                        }
                }
                FREE_OP_VAR_PTR(free_op_data2);
@@ -27724,49 +29733,72 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLE
        }
 
        /* assign_dim has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
-       zval *value = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       zval **variable_ptr_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       zval *value;
+       zval **variable_ptr_ptr;
 
-       if (IS_CV == IS_VAR && !variable_ptr_ptr) {
+       SAVE_OPLINE();
+       value = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+       variable_ptr_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr_ptr == NULL)) {
                if (zend_assign_to_string_offset(&EX_T(opline->op1.var), value, IS_VAR TSRMLS_CC)) {
                        if (RETURN_VALUE_USED(opline)) {
-                               EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-                               ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                               INIT_PZVAL(EX_T(opline->result.var).var.ptr);
-                               ZVAL_STRINGL(EX_T(opline->result.var).var.ptr, Z_STRVAL_P(EX_T(opline->op1.var).str_offset.str)+EX_T(opline->op1.var).str_offset.offset, 1, 1);
+                               zval *retval;
+
+                               ALLOC_ZVAL(retval);
+                               ZVAL_STRINGL(retval, Z_STRVAL_P(EX_T(opline->op1.var).str_offset.str)+EX_T(opline->op1.var).str_offset.offset, 1, 1);
+                               INIT_PZVAL(retval);
+                               AI_SET_PTR(&EX_T(opline->result.var), retval);
                        }
                } else if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+               }
+       } else if (IS_CV == IS_VAR && UNEXPECTED(*variable_ptr_ptr == &EG(error_zval))) {
+               if (0) {
+                       zval_dtor(value);
+               }
+               if (RETURN_VALUE_USED(opline)) {
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
        } else {
-               value = zend_assign_to_variable(variable_ptr_ptr, value, 0 TSRMLS_CC);
+               if (0) {
+                       value = zend_assign_tmp_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+               } else {
+                       value = zend_assign_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+               }
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, value);
                        PZVAL_LOCK(value);
+                       AI_SET_PTR(&EX_T(opline->result.var), value);
                }
        }
 
        /* zend_assign_to_variable() always takes care of op2, never free it! */
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_REF_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval **variable_ptr_ptr;
-       zval **value_ptr_ptr = _get_zval_ptr_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **value_ptr_ptr;
+
+       SAVE_OPLINE();
+       value_ptr_ptr = _get_zval_ptr_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
        if (IS_VAR == IS_VAR &&
            value_ptr_ptr &&
@@ -27779,19 +29811,19 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_REF_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLE
                zend_error(E_STRICT, "Only variables should be assigned by reference");
                if (UNEXPECTED(EG(exception) != NULL)) {
                        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
-                       ZEND_VM_NEXT_OPCODE();
+                       HANDLE_EXCEPTION();
                }
                return ZEND_ASSIGN_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (IS_VAR == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
                PZVAL_LOCK(*value_ptr_ptr);
        }
-       if (IS_CV == IS_VAR && EX_T(opline->op1.var).var.ptr_ptr == &EX_T(opline->op1.var).var.ptr) {
+       if (IS_CV == IS_VAR && UNEXPECTED(EX_T(opline->op1.var).var.ptr_ptr == &EX_T(opline->op1.var).var.ptr)) {
                zend_error_noreturn(E_ERROR, "Cannot assign by reference to overloaded object");
        }
 
-       variable_ptr_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
-       if ((IS_VAR == IS_VAR && !value_ptr_ptr) ||
-           (IS_CV == IS_VAR && !variable_ptr_ptr)) {
+       variable_ptr_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+       if ((IS_VAR == IS_VAR && UNEXPECTED(value_ptr_ptr == NULL)) ||
+           (IS_CV == IS_VAR && UNEXPECTED(variable_ptr_ptr == NULL))) {
                zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
        }
        zend_assign_to_variable_reference(variable_ptr_ptr, value_ptr_ptr TSRMLS_CC);
@@ -27801,44 +29833,48 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_REF_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLE
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *variable_ptr_ptr);
                PZVAL_LOCK(*variable_ptr_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *variable_ptr_ptr);
        }
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        char *function_name_strval;
        int function_name_strlen;
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
-       function_name = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       function_name = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
-       if (Z_TYPE_P(function_name)!=IS_STRING) {
+       if (IS_VAR != IS_CONST &&
+           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                zend_error_noreturn(E_ERROR, "Method name must be a string");
        }
 
        function_name_strval = Z_STRVAL_P(function_name);
        function_name_strlen = Z_STRLEN_P(function_name);
 
-       EX(object) = _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+       EX(object) = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       if (EX(object) && Z_TYPE_P(EX(object)) == IS_OBJECT) {
-               if (Z_OBJ_HT_P(EX(object))->get_method == NULL) {
+       if (EXPECTED(EX(object) != NULL) &&
+           EXPECTED(Z_TYPE_P(EX(object)) == IS_OBJECT)) {
+               if (UNEXPECTED(Z_OBJ_HT_P(EX(object))->get_method == NULL)) {
                        zend_error_noreturn(E_ERROR, "Object does not support method calls");
                }
 
                /* First, locate the function. */
                EX(fbc) = Z_OBJ_HT_P(EX(object))->get_method(&EX(object), function_name_strval, function_name_strlen, ((IS_VAR == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
-               if (!EX(fbc)) {
+               if (UNEXPECTED(EX(fbc) == NULL)) {
                        zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", Z_OBJ_CLASS_NAME_P(EX(object)), function_name_strval);
                }
 
@@ -27863,15 +29899,17 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CASE_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        int switch_expr_is_overloaded=0;
        zend_free_op free_op2;
 
+       SAVE_OPLINE();
        if (IS_CV==IS_VAR) {
                if (EX_T(opline->op1.var).var.ptr_ptr) {
                        PZVAL_LOCK(EX_T(opline->op1.var).var.ptr);
@@ -27881,8 +29919,8 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS
                }
        }
        is_equal_function(&EX_T(opline->result.var).tmp_var,
-                                _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-                                _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC) TSRMLS_CC);
+                                _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+                                _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC) TSRMLS_CC);
 
        if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        if (switch_expr_is_overloaded) {
@@ -27895,47 +29933,32 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS
                EX_T(opline->op1.var).var.ptr_ptr = NULL;
                EX_T(opline->op1.var).var.ptr = NULL;
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_free_op free_op2;
-       zval *array_ptr = &EX_T(opline->result.var).tmp_var;
+       USE_OPLINE
+
        zval *expr_ptr;
-       zval *offset=_get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
-       ulong hval;
-       long index;
 
-#if 0 || IS_CV == IS_VAR || IS_CV == IS_CV
-       zval **expr_ptr_ptr = NULL;
+       SAVE_OPLINE();
+       if ((IS_CV == IS_VAR || IS_CV == IS_CV) && opline->extended_value) {
+               zval **expr_ptr_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       if (opline->extended_value) {
-               expr_ptr_ptr=_get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
                expr_ptr = *expr_ptr_ptr;
+               Z_ADDREF_P(expr_ptr);
        } else {
-               expr_ptr=_get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
-       }
-#else
-       expr_ptr=_get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
-#endif
-
-       if (0) { /* temporary variable */
-               zval *new_expr;
+               expr_ptr=_get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+               if (0) { /* temporary variable */
+                       zval *new_expr;
 
-               ALLOC_ZVAL(new_expr);
-               INIT_PZVAL_COPY(new_expr, expr_ptr);
-               expr_ptr = new_expr;
-       } else {
-#if 0 || IS_CV == IS_VAR || IS_CV == IS_CV
-               if (opline->extended_value) {
-                       SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
-                       expr_ptr = *expr_ptr_ptr;
-                       Z_ADDREF_P(expr_ptr);
-               } else
-#endif
-               if (IS_CV == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
+                       ALLOC_ZVAL(new_expr);
+                       INIT_PZVAL_COPY(new_expr, expr_ptr);
+                       expr_ptr = new_expr;
+               } else if (IS_CV == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
                        zval *new_expr;
 
                        ALLOC_ZVAL(new_expr);
@@ -27946,7 +29969,13 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_VAR_HANDLER(ZEND_OPCODE
                        Z_ADDREF_P(expr_ptr);
                }
        }
-       if (offset) {
+
+       if (IS_VAR != IS_UNUSED) {
+               zend_free_op free_op2;
+               zval *offset = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+               ulong hval;
+               long index;
+
                switch (Z_TYPE_P(offset)) {
                        case IS_DOUBLE:
                                index = zend_dval_to_lval(Z_DVAL_P(offset));
@@ -27955,7 +29984,7 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_VAR_HANDLER(ZEND_OPCODE
                        case IS_BOOL:
                                index = Z_LVAL_P(offset);
 num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(array_ptr), index, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_index_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), index, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_STRING:
                                if (IS_VAR == IS_CONST) {
@@ -27968,10 +29997,10 @@ num_index:
                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                        }
                                }
-                               zend_hash_quick_update(Z_ARRVAL_P(array_ptr), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_quick_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_NULL:
-                               zend_hash_update(Z_ARRVAL_P(array_ptr), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
                                break;
                        default:
                                zend_error(E_WARNING, "Illegal offset type");
@@ -27981,19 +30010,20 @@ num_index:
                }
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(array_ptr), &expr_ptr, sizeof(zval *), NULL);
+               zend_hash_next_index_insert(Z_ARRVAL(EX_T(opline->result.var).tmp_var), &expr_ptr, sizeof(zval *), NULL);
        }
-       if (opline->extended_value) {
+       if ((IS_CV == IS_VAR || IS_CV == IS_CV) && opline->extended_value) {
 
        } else {
 
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (IS_CV == IS_UNUSED) {
@@ -28007,13 +30037,17 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLE
 
 static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_UNSET TSRMLS_CC);
-       zval *offset = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **container;
+       zval *offset;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_UNSET(EX_CVs(), opline->op1.var TSRMLS_CC);
+       offset = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
+
        if (IS_CV != IS_VAR || container) {
                if (IS_CV == IS_CV && container != &EG(uninitialized_zval_ptr)) {
                        SEPARATE_ZVAL_IF_NOT_REF(container);
@@ -28047,24 +30081,10 @@ num_index_dim:
                                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                                        }
                                                }
-                                               if (zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval) == SUCCESS &&
-                                           ht == &EG(symbol_table)) {
-                                                       zend_execute_data *ex;
-
-                                                       for (ex = execute_data; ex; ex = ex->prev_execute_data) {
-                                                               if (ex->op_array && ex->symbol_table == ht) {
-                                                                       int i;
-
-                                                                       for (i = 0; i < ex->op_array->last_var; i++) {
-                                                                               if (ex->op_array->vars[i].hash_value == hval &&
-                                                                                   ex->op_array->vars[i].name_len == offset->value.str.len &&
-                                                                                   !memcmp(ex->op_array->vars[i].name, offset->value.str.val, offset->value.str.len)) {
-                                                                                       ex->CVs[i] = NULL;
-                                                                                       break;
-                                                                               }
-                                                                       }
-                                                               }
-                                                       }
+                                               if (ht == &EG(symbol_table)) {
+                                                       zend_delete_global_variable_ex(offset->value.str.val, offset->value.str.len, hval TSRMLS_CC);
+                                               } else {
+                                                       zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval);
                                                }
                                                if (IS_VAR == IS_CV || IS_VAR == IS_VAR) {
                                                        zval_ptr_dtor(&offset);
@@ -28081,7 +30101,7 @@ num_index_dim:
                                break;
                        }
                        case IS_OBJECT:
-                               if (!Z_OBJ_HT_P(*container)->unset_dimension) {
+                               if (UNEXPECTED(Z_OBJ_HT_P(*container)->unset_dimension == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use object as array");
                                }
                                if (0) {
@@ -28105,15 +30125,20 @@ num_index_dim:
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_UNSET TSRMLS_CC);
-       zval *offset = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+       zval **container;
+       zval *offset;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_UNSET(EX_CVs(), opline->op1.var TSRMLS_CC);
+       offset = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
        if (IS_CV != IS_VAR || container) {
                if (IS_CV == IS_CV && container != &EG(uninitialized_zval_ptr)) {
@@ -28140,22 +30165,26 @@ static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_CV_VAR_HANDLER(ZEND_OPCODE_HANDLER
                if (free_op2.var) {zval_ptr_dtor(&free_op2.var);};
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_isset_isempty_dim_prop_obj_handler_SPEC_CV_VAR(int prop_dim, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_IS TSRMLS_CC);
+       zval **container;
        zval **value = NULL;
        int result = 0;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_IS(EX_CVs(), opline->op1.var TSRMLS_CC);
+
        if (IS_CV != IS_VAR || container) {
                zend_free_op free_op2;
-               zval *offset = _get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC);
+               zval *offset = _get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC);
 
                if (Z_TYPE_PP(container) == IS_ARRAY && !prop_dim) {
                        HashTable *ht;
@@ -28246,7 +30275,7 @@ num_index_prop:
                        zval tmp;
 
                        if (Z_TYPE_P(offset) != IS_LONG) {
-                               tmp = *offset;
+                               ZVAL_COPY_VALUE(&tmp, offset);
                                zval_copy_ctor(&tmp);
                                convert_to_long(&tmp);
                                offset = &tmp;
@@ -28269,13 +30298,13 @@ num_index_prop:
        }
 
        Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
-
        if (opline->extended_value & ZEND_ISSET) {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = result;
-       } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+       } else {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = !result;
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -28291,33 +30320,31 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_VAR_HANDLER(ZEND_O
 
 static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op_data1;
-       zval **object_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       zval **object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
        zval *object;
        zval *property = NULL;
-       zval *value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
+       zval *value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
        znode_op *result = &opline->result;
        int have_get_ptr = 0;
 
-       if (IS_CV == IS_VAR && !object_ptr) {
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
 
-       EX_T(result->var).var.ptr_ptr = NULL;
        make_real_object(object_ptr TSRMLS_CC);
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to assign property of non-object");
 
                FREE_OP(free_op_data1);
 
                if (RETURN_VALUE_USED(opline)) {
-                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                       EX_T(result->var).var.ptr_ptr = NULL;
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                }
        } else {
                /* here we are sure we are dealing with an object */
@@ -28335,9 +30362,9 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(int (*b
                                have_get_ptr = 1;
                                binary_op(*zptr, *zptr, value TSRMLS_CC);
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = *zptr;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(*zptr);
+                                       EX_T(opline->result.var).var.ptr = *zptr;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -28374,17 +30401,17 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(int (*b
                                        Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
                                }
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = z;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(z);
+                                       EX_T(opline->result.var).var.ptr = z;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                                zval_ptr_dtor(&z);
                        } else {
                                zend_error(E_WARNING, "Attempt to assign property of non-object");
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                                       EX_T(result->var).var.ptr_ptr = NULL;
-                                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                                       PZVAL_LOCK(&EG(uninitialized_zval));
+                                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -28398,66 +30425,71 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(int (*b
        }
 
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_UNUSED(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op_data2, free_op_data1;
        zval **var_ptr;
        zval *value;
 
+       SAVE_OPLINE();
        switch (opline->extended_value) {
                case ZEND_ASSIGN_OBJ:
                        return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                        break;
                case ZEND_ASSIGN_DIM: {
-                               zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_RW TSRMLS_CC);
+                               zval **container = _get_zval_ptr_ptr_cv_BP_VAR_RW(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-                               if (IS_CV == IS_VAR && !container) {
+                               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-                               } else if (Z_TYPE_PP(container) == IS_OBJECT) {
+                               } else if (UNEXPECTED(Z_TYPE_PP(container) == IS_OBJECT)) {
                                        if (IS_CV == IS_VAR && !0) {
                                                Z_ADDREF_PP(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
                                        }
                                        return zend_binary_assign_op_obj_helper_SPEC_CV_UNUSED(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                                } else {
-                                       zend_op *op_data = opline+1;
                                        zval *dim = NULL;
 
-                                       zend_fetch_dimension_address(&EX_T(op_data->op2.var), container, dim, IS_UNUSED, BP_VAR_RW TSRMLS_CC);
-                                       value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-                                       var_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-                                       ZEND_VM_INC_OPCODE();
+                                       zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), container, dim, IS_UNUSED, BP_VAR_RW TSRMLS_CC);
+                                       value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+                                       var_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
                                }
                        }
                        break;
                default:
                        value = NULL;
-                       var_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_RW TSRMLS_CC);
+                       var_ptr = _get_zval_ptr_ptr_cv_BP_VAR_RW(EX_CVs(), opline->op1.var TSRMLS_CC);
                        /* do nothing */
                        break;
        }
 
-       if (!var_ptr) {
+       if (UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
        }
 
-       if (*var_ptr == EG(error_zval_ptr)) {
+       if (UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
 
 
+               CHECK_EXCEPTION();
+               if (opline->extended_value == ZEND_ASSIGN_DIM) {
+                       ZEND_VM_INC_OPCODE();
+               }
                ZEND_VM_NEXT_OPCODE();
        }
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *objval = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -28470,15 +30502,20 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_UNUSED(int (*binar
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *var_ptr);
                PZVAL_LOCK(*var_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *var_ptr);
        }
 
        if (opline->extended_value == ZEND_ASSIGN_DIM) {
                FREE_OP(free_op_data1);
                FREE_OP_VAR_PTR(free_op_data2);
-       }
 
+               CHECK_EXCEPTION();
+               ZEND_VM_INC_OPCODE();
+       } else {
+
+               CHECK_EXCEPTION();
+       }
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -28539,103 +30576,102 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *dim = NULL;
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       zval **container;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && !container) {
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_UNUSED, BP_VAR_W TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, NULL, IS_UNUSED, BP_VAR_W TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
        /* We are going to assign the result by reference */
-       if (opline->extended_value && EX_T(opline->result.var).var.ptr_ptr) {
-               Z_DELREF_PP(EX_T(opline->result.var).var.ptr_ptr);
-               SEPARATE_ZVAL_TO_MAKE_IS_REF(EX_T(opline->result.var).var.ptr_ptr);
-               Z_ADDREF_PP(EX_T(opline->result.var).var.ptr_ptr);
+       if (UNEXPECTED(opline->extended_value != 0)) {
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+
+               if (retval_ptr) {
+                       Z_DELREF_PP(retval_ptr);
+                       SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
+                       Z_ADDREF_PP(retval_ptr);
+               }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *dim = NULL;
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_RW TSRMLS_CC);
+       zval **container;
 
-       if (IS_CV == IS_VAR && !container) {
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_RW(EX_CVs(), opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_UNUSED, BP_VAR_RW TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, NULL, IS_UNUSED, BP_VAR_RW TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *dim = NULL;
        zval **container;
 
+       SAVE_OPLINE();
+
        if (ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))) {
-               container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
-               if (IS_CV == IS_VAR && !container) {
+               container = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_UNUSED, BP_VAR_W TSRMLS_CC);
-               if (IS_CV == IS_VAR && 0 &&
-                   READY_TO_DESTROY(free_op1.var)) {
-                       AI_USE_PTR(EX_T(opline->result.var).var);
-                       if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                           Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                               SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-                       }
+               zend_fetch_dimension_address(&EX_T(opline->result.var), container, NULL, IS_UNUSED, BP_VAR_W TSRMLS_CC);
+               if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+                       EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
                }
        } else {
                if (IS_UNUSED == IS_UNUSED) {
                        zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
                }
-               container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
-               if (IS_CV == IS_VAR && !container) {
+               container = _get_zval_ptr_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, dim, IS_UNUSED, BP_VAR_R TSRMLS_CC);
+               zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, NULL, IS_UNUSED, BP_VAR_R TSRMLS_CC);
        }
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
 
-       zval **object_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       zval **object_ptr;
 
-       if (IS_CV == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
        if (Z_TYPE_PP(object_ptr) == IS_OBJECT) {
@@ -28645,7 +30681,7 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HAN
                if (0) {
                        MAKE_REAL_ZVAL_PTR(property_name);
                }
-               zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, op_data->op1_type, &op_data->op1, EX(Ts), ZEND_ASSIGN_DIM, ((IS_UNUSED == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+               zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), ZEND_ASSIGN_DIM, ((IS_UNUSED == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
                if (0) {
                        zval_ptr_dtor(&property_name);
                } else {
@@ -28657,27 +30693,41 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HAN
                zval *dim = NULL;
                zval **variable_ptr_ptr;
 
-               zend_fetch_dimension_address(&EX_T(op_data->op2.var), object_ptr, dim, IS_UNUSED, BP_VAR_W TSRMLS_CC);
+               zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), object_ptr, dim, IS_UNUSED, BP_VAR_W TSRMLS_CC);
 
-               value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-               variable_ptr_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-               if (!variable_ptr_ptr) {
-                       if (zend_assign_to_string_offset(&EX_T(op_data->op2.var), value, op_data->op1_type TSRMLS_CC)) {
+               value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+               variable_ptr_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
+               if (UNEXPECTED(variable_ptr_ptr == NULL)) {
+                       if (zend_assign_to_string_offset(&EX_T((opline+1)->op2.var), value, (opline+1)->op1_type TSRMLS_CC)) {
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-                                       ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                                       INIT_PZVAL(EX_T(opline->result.var).var.ptr);
-                                       ZVAL_STRINGL(EX_T(opline->result.var).var.ptr, Z_STRVAL_P(EX_T(op_data->op2.var).str_offset.str)+EX_T(op_data->op2.var).str_offset.offset, 1, 1);
+                                       zval *retval;
+
+                                       ALLOC_ZVAL(retval);
+                                       ZVAL_STRINGL(retval, Z_STRVAL_P(EX_T((opline+1)->op2.var).str_offset.str)+EX_T((opline+1)->op2.var).str_offset.offset, 1, 1);
+                                       INIT_PZVAL(retval);
+                                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                                }
                        } else if (RETURN_VALUE_USED(opline)) {
-                               AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                               PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+                       }
+               } else if (UNEXPECTED(*variable_ptr_ptr == &EG(error_zval))) {
+                       if (IS_TMP_FREE(free_op_data1)) {
+                               zval_dtor(value);
+                       }
+                       if (RETURN_VALUE_USED(opline)) {
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                        }
                } else {
-                       value = zend_assign_to_variable(variable_ptr_ptr, value, IS_TMP_FREE(free_op_data1) TSRMLS_CC);
+                       if (IS_TMP_FREE(free_op_data1)) {
+                               value = zend_assign_tmp_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+                       } else {
+                               value = zend_assign_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+                       }
                        if (RETURN_VALUE_USED(opline)) {
-                               AI_SET_PTR(EX_T(opline->result.var).var, value);
                                PZVAL_LOCK(value);
+                               AI_SET_PTR(&EX_T(opline->result.var), value);
                        }
                }
                FREE_OP_VAR_PTR(free_op_data2);
@@ -28685,48 +30735,33 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HAN
        }
 
        /* assign_dim has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *array_ptr = &EX_T(opline->result.var).tmp_var;
        zval *expr_ptr;
-       zval *offset=NULL;
-       ulong hval;
-       long index;
 
-#if 0 || IS_CV == IS_VAR || IS_CV == IS_CV
-       zval **expr_ptr_ptr = NULL;
+       SAVE_OPLINE();
+       if ((IS_CV == IS_VAR || IS_CV == IS_CV) && opline->extended_value) {
+               zval **expr_ptr_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       if (opline->extended_value) {
-               expr_ptr_ptr=_get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
                expr_ptr = *expr_ptr_ptr;
+               Z_ADDREF_P(expr_ptr);
        } else {
-               expr_ptr=_get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
-       }
-#else
-       expr_ptr=_get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
-#endif
-
-       if (0) { /* temporary variable */
-               zval *new_expr;
+               expr_ptr=_get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+               if (0) { /* temporary variable */
+                       zval *new_expr;
 
-               ALLOC_ZVAL(new_expr);
-               INIT_PZVAL_COPY(new_expr, expr_ptr);
-               expr_ptr = new_expr;
-       } else {
-#if 0 || IS_CV == IS_VAR || IS_CV == IS_CV
-               if (opline->extended_value) {
-                       SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
-                       expr_ptr = *expr_ptr_ptr;
-                       Z_ADDREF_P(expr_ptr);
-               } else
-#endif
-               if (IS_CV == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
+                       ALLOC_ZVAL(new_expr);
+                       INIT_PZVAL_COPY(new_expr, expr_ptr);
+                       expr_ptr = new_expr;
+               } else if (IS_CV == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
                        zval *new_expr;
 
                        ALLOC_ZVAL(new_expr);
@@ -28737,7 +30772,13 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_UNUSED_HANDLER(ZEND_OPC
                        Z_ADDREF_P(expr_ptr);
                }
        }
-       if (offset) {
+
+       if (IS_UNUSED != IS_UNUSED) {
+
+               zval *offset = NULL;
+               ulong hval;
+               long index;
+
                switch (Z_TYPE_P(offset)) {
                        case IS_DOUBLE:
                                index = zend_dval_to_lval(Z_DVAL_P(offset));
@@ -28746,7 +30787,7 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_UNUSED_HANDLER(ZEND_OPC
                        case IS_BOOL:
                                index = Z_LVAL_P(offset);
 num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(array_ptr), index, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_index_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), index, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_STRING:
                                if (IS_UNUSED == IS_CONST) {
@@ -28759,10 +30800,10 @@ num_index:
                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                        }
                                }
-                               zend_hash_quick_update(Z_ARRVAL_P(array_ptr), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_quick_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_NULL:
-                               zend_hash_update(Z_ARRVAL_P(array_ptr), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
                                break;
                        default:
                                zend_error(E_WARNING, "Illegal offset type");
@@ -28772,19 +30813,20 @@ num_index:
                }
 
        } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(array_ptr), &expr_ptr, sizeof(zval *), NULL);
+               zend_hash_next_index_insert(Z_ARRVAL(EX_T(opline->result.var).tmp_var), &expr_ptr, sizeof(zval *), NULL);
        }
-       if (opline->extended_value) {
+       if ((IS_CV == IS_VAR || IS_CV == IS_CV) && opline->extended_value) {
 
        } else {
 
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (IS_CV == IS_UNUSED) {
@@ -28798,277 +30840,311 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CV_UNUSED_HANDLER(ZEND_OPCODE_HAN
 
 static int ZEND_FASTCALL  ZEND_ADD_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        add_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SUB_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        sub_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MUL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        mul_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_DIV_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        div_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_MOD_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        mod_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        shift_left_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_SR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        shift_right_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CONCAT_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        concat_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_IDENTICAL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        is_identical_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_IDENTICAL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        is_identical_function(result,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        Z_LVAL_P(result) = !Z_LVAL_P(result);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_EQUAL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) == 0));
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_NOT_EQUAL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) != 0));
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) < 0));
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_IS_SMALLER_OR_EQUAL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        zval *result = &EX_T(opline->result.var).tmp_var;
 
+       SAVE_OPLINE();
        compare_function(result,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
        ZVAL_BOOL(result, (Z_LVAL_P(result) <= 0));
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_OR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        bitwise_or_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_AND_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        bitwise_and_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BW_XOR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        bitwise_xor_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_BOOL_XOR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
 
+       SAVE_OPLINE();
        boolean_xor_function(&EX_T(opline->result.var).tmp_var,
-               _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-               _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+               _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_CV(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
        zend_free_op free_op_data1;
-       zval **object_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       zval **object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
        zval *object;
-       zval *property = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-       zval *value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
+       zval *property = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+       zval *value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
        znode_op *result = &opline->result;
        int have_get_ptr = 0;
 
-       if (IS_CV == IS_VAR && !object_ptr) {
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
 
-       EX_T(result->var).var.ptr_ptr = NULL;
        make_real_object(object_ptr TSRMLS_CC);
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to assign property of non-object");
 
                FREE_OP(free_op_data1);
 
                if (RETURN_VALUE_USED(opline)) {
-                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                       EX_T(result->var).var.ptr_ptr = NULL;
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                }
        } else {
                /* here we are sure we are dealing with an object */
@@ -29086,9 +31162,9 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_CV(int (*binar
                                have_get_ptr = 1;
                                binary_op(*zptr, *zptr, value TSRMLS_CC);
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = *zptr;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(*zptr);
+                                       EX_T(opline->result.var).var.ptr = *zptr;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -29125,17 +31201,17 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_CV(int (*binar
                                        Z_OBJ_HT_P(object)->write_dimension(object, property, z TSRMLS_CC);
                                }
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = z;
-                                       EX_T(result->var).var.ptr_ptr = NULL;
                                        PZVAL_LOCK(z);
+                                       EX_T(opline->result.var).var.ptr = z;
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                                zval_ptr_dtor(&z);
                        } else {
                                zend_error(E_WARNING, "Attempt to assign property of non-object");
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(result->var).var.ptr = EG(uninitialized_zval_ptr);
-                                       EX_T(result->var).var.ptr_ptr = NULL;
-                                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                                       PZVAL_LOCK(&EG(uninitialized_zval));
+                                       EX_T(opline->result.var).var.ptr = &EG(uninitialized_zval);
+                                       EX_T(opline->result.var).var.ptr_ptr = NULL;
                                }
                        }
                }
@@ -29149,66 +31225,71 @@ static int ZEND_FASTCALL zend_binary_assign_op_obj_helper_SPEC_CV_CV(int (*binar
        }
 
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_CV(int (*binary_op)(zval *result, zval *op1, zval *op2 TSRMLS_DC), ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op_data2, free_op_data1;
        zval **var_ptr;
        zval *value;
 
+       SAVE_OPLINE();
        switch (opline->extended_value) {
                case ZEND_ASSIGN_OBJ:
                        return zend_binary_assign_op_obj_helper_SPEC_CV_CV(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                        break;
                case ZEND_ASSIGN_DIM: {
-                               zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_RW TSRMLS_CC);
+                               zval **container = _get_zval_ptr_ptr_cv_BP_VAR_RW(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-                               if (IS_CV == IS_VAR && !container) {
+                               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
-                               } else if (Z_TYPE_PP(container) == IS_OBJECT) {
+                               } else if (UNEXPECTED(Z_TYPE_PP(container) == IS_OBJECT)) {
                                        if (IS_CV == IS_VAR && !0) {
                                                Z_ADDREF_PP(container);  /* undo the effect of get_obj_zval_ptr_ptr() */
                                        }
                                        return zend_binary_assign_op_obj_helper_SPEC_CV_CV(binary_op, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
                                } else {
-                                       zend_op *op_data = opline+1;
-                                       zval *dim = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+                                       zval *dim = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
 
-                                       zend_fetch_dimension_address(&EX_T(op_data->op2.var), container, dim, IS_CV, BP_VAR_RW TSRMLS_CC);
-                                       value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-                                       var_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-                                       ZEND_VM_INC_OPCODE();
+                                       zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), container, dim, IS_CV, BP_VAR_RW TSRMLS_CC);
+                                       value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+                                       var_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
                                }
                        }
                        break;
                default:
-                       value = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-                       var_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_RW TSRMLS_CC);
+                       value = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+                       var_ptr = _get_zval_ptr_ptr_cv_BP_VAR_RW(EX_CVs(), opline->op1.var TSRMLS_CC);
                        /* do nothing */
                        break;
        }
 
-       if (!var_ptr) {
+       if (UNEXPECTED(var_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use assign-op operators with overloaded objects nor string offsets");
        }
 
-       if (*var_ptr == EG(error_zval_ptr)) {
+       if (UNEXPECTED(*var_ptr == &EG(error_zval))) {
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
 
 
+               CHECK_EXCEPTION();
+               if (opline->extended_value == ZEND_ASSIGN_DIM) {
+                       ZEND_VM_INC_OPCODE();
+               }
                ZEND_VM_NEXT_OPCODE();
        }
 
        SEPARATE_ZVAL_IF_NOT_REF(var_ptr);
 
-       if(Z_TYPE_PP(var_ptr) == IS_OBJECT && Z_OBJ_HANDLER_PP(var_ptr, get)
+       if (UNEXPECTED(Z_TYPE_PP(var_ptr) == IS_OBJECT)
+          && Z_OBJ_HANDLER_PP(var_ptr, get)
           && Z_OBJ_HANDLER_PP(var_ptr, set)) {
                /* proxy object */
                zval *objval = Z_OBJ_HANDLER_PP(var_ptr, get)(*var_ptr TSRMLS_CC);
@@ -29221,15 +31302,20 @@ static int ZEND_FASTCALL zend_binary_assign_op_helper_SPEC_CV_CV(int (*binary_op
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *var_ptr);
                PZVAL_LOCK(*var_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *var_ptr);
        }
 
        if (opline->extended_value == ZEND_ASSIGN_DIM) {
                FREE_OP(free_op_data1);
                FREE_OP_VAR_PTR(free_op_data2);
-       }
 
+               CHECK_EXCEPTION();
+               ZEND_VM_INC_OPCODE();
+       } else {
+
+               CHECK_EXCEPTION();
+       }
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -29290,29 +31376,35 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_BW_XOR_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HAND
 
 static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_CV(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval **object_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       zval **object_ptr;
        zval *object;
-       zval *property = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-       zval **retval = &EX_T(opline->result.var).var.ptr;
+       zval *property;
+       zval **retval;
        int have_get_ptr = 0;
 
-       if (IS_CV == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+       property = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+       retval = &EX_T(opline->result.var).var.ptr;
+
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
 
                if (RETURN_VALUE_USED(opline)) {
-                       *retval = EG(uninitialized_zval_ptr);
-                       PZVAL_LOCK(*retval);
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       *retval = &EG(uninitialized_zval);
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -29340,7 +31432,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_CV(incdec_t inc
                if (Z_OBJ_HT_P(object)->read_property && Z_OBJ_HT_P(object)->write_property) {
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -29360,8 +31452,8 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_CV(incdec_t inc
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
                        if (RETURN_VALUE_USED(opline)) {
-                               *retval = EG(uninitialized_zval_ptr);
-                               PZVAL_LOCK(*retval);
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               *retval = &EG(uninitialized_zval);
                        }
                }
        }
@@ -29372,6 +31464,7 @@ static int ZEND_FASTCALL zend_pre_incdec_property_helper_SPEC_CV_CV(incdec_t inc
 
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -29387,26 +31480,32 @@ static int ZEND_FASTCALL  ZEND_PRE_DEC_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLE
 
 static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CV(incdec_t incdec_op, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval **object_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       zval **object_ptr;
        zval *object;
-       zval *property = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-       zval *retval = &EX_T(opline->result.var).tmp_var;
+       zval *property;
+       zval *retval;
        int have_get_ptr = 0;
 
-       if (IS_CV == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+       property = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+       retval = &EX_T(opline->result.var).tmp_var;
+
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot increment/decrement overloaded objects nor string offsets");
        }
 
        make_real_object(object_ptr TSRMLS_CC); /* this should modify object only if it's empty */
        object = *object_ptr;
 
-       if (Z_TYPE_P(object) != IS_OBJECT) {
+       if (UNEXPECTED(Z_TYPE_P(object) != IS_OBJECT)) {
                zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
 
-               *retval = *EG(uninitialized_zval_ptr);
+               ZVAL_NULL(retval);
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        }
 
@@ -29422,7 +31521,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CV(incdec_t in
                        have_get_ptr = 1;
                        SEPARATE_ZVAL_IF_NOT_REF(zptr);
 
-                       *retval = **zptr;
+                       ZVAL_COPY_VALUE(retval, *zptr);
                        zendi_zval_copy_ctor(*retval);
 
                        incdec_op(*zptr);
@@ -29435,7 +31534,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CV(incdec_t in
                        zval *z = Z_OBJ_HT_P(object)->read_property(object, property, BP_VAR_R, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
                        zval *z_copy;
 
-                       if (Z_TYPE_P(z) == IS_OBJECT && Z_OBJ_HT_P(z)->get) {
+                       if (UNEXPECTED(Z_TYPE_P(z) == IS_OBJECT) && Z_OBJ_HT_P(z)->get) {
                                zval *value = Z_OBJ_HT_P(z)->get(z TSRMLS_CC);
 
                                if (Z_REFCOUNT_P(z) == 0) {
@@ -29445,12 +31544,11 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CV(incdec_t in
                                }
                                z = value;
                        }
-                       *retval = *z;
+                       ZVAL_COPY_VALUE(retval, z);
                        zendi_zval_copy_ctor(*retval);
                        ALLOC_ZVAL(z_copy);
-                       *z_copy = *z;
+                       INIT_PZVAL_COPY(z_copy, z);
                        zendi_zval_copy_ctor(*z_copy);
-                       INIT_PZVAL(z_copy);
                        incdec_op(z_copy);
                        Z_ADDREF_P(z);
                        Z_OBJ_HT_P(object)->write_property(object, property, z_copy, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
@@ -29458,7 +31556,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CV(incdec_t in
                        zval_ptr_dtor(&z);
                } else {
                        zend_error(E_WARNING, "Attempt to increment/decrement property of non-object");
-                       *retval = *EG(uninitialized_zval_ptr);
+                       ZVAL_NULL(retval);
                }
        }
 
@@ -29468,6 +31566,7 @@ static int ZEND_FASTCALL zend_post_incdec_property_helper_SPEC_CV_CV(incdec_t in
 
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -29483,194 +31582,193 @@ static int ZEND_FASTCALL  ZEND_POST_DEC_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDL
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_R_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *dim = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
        zval **container;
 
+       SAVE_OPLINE();
+
        if ((opline->extended_value & ZEND_FETCH_ADD_LOCK) &&
            IS_CV != IS_CV &&
            EX_T(opline->op1.var).var.ptr_ptr) {
                PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
        }
-       container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
-       if (IS_CV == IS_VAR && !container) {
+       container = _get_zval_ptr_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address_read(!RETURN_VALUE_USED(opline)?NULL:&EX_T(opline->result.var), container, dim, IS_CV, BP_VAR_R TSRMLS_CC);
+       zend_fetch_dimension_address_read(!RETURN_VALUE_USED(opline)?NULL:&EX_T(opline->result.var), container, _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC), IS_CV, BP_VAR_R TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_W_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *dim = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       zval **container;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && !container) {
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_CV, BP_VAR_W TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC), IS_CV, BP_VAR_W TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
        /* We are going to assign the result by reference */
-       if (opline->extended_value && EX_T(opline->result.var).var.ptr_ptr) {
-               Z_DELREF_PP(EX_T(opline->result.var).var.ptr_ptr);
-               SEPARATE_ZVAL_TO_MAKE_IS_REF(EX_T(opline->result.var).var.ptr_ptr);
-               Z_ADDREF_PP(EX_T(opline->result.var).var.ptr_ptr);
+       if (UNEXPECTED(opline->extended_value != 0)) {
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+
+               if (retval_ptr) {
+                       Z_DELREF_PP(retval_ptr);
+                       SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
+                       Z_ADDREF_PP(retval_ptr);
+               }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_RW_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *dim = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_RW TSRMLS_CC);
+       zval **container;
 
-       if (IS_CV == IS_VAR && !container) {
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_RW(EX_CVs(), opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_CV, BP_VAR_RW TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC), IS_CV, BP_VAR_RW TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_IS_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *dim = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_IS TSRMLS_CC);
+       zval **container;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_IS(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && !container) {
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, dim, IS_CV, BP_VAR_IS TSRMLS_CC);
+       zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC), IS_CV, BP_VAR_IS TSRMLS_CC);
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_FUNC_ARG_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *dim = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
        zval **container;
 
+       SAVE_OPLINE();
+
        if (ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))) {
-               container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
-               if (IS_CV == IS_VAR && !container) {
+               container = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_CV, BP_VAR_W TSRMLS_CC);
-               if (IS_CV == IS_VAR && 0 &&
-                   READY_TO_DESTROY(free_op1.var)) {
-                       AI_USE_PTR(EX_T(opline->result.var).var);
-                       if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                           Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                               SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-                       }
+               zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC), IS_CV, BP_VAR_W TSRMLS_CC);
+               if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+                       EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
                }
        } else {
                if (IS_CV == IS_UNUSED) {
                        zend_error_noreturn(E_ERROR, "Cannot use [] for reading");
                }
-               container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
-               if (IS_CV == IS_VAR && !container) {
+               container = _get_zval_ptr_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
                }
-               zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, dim, IS_CV, BP_VAR_R TSRMLS_CC);
+               zend_fetch_dimension_address_read(&EX_T(opline->result.var), container, _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC), IS_CV, BP_VAR_R TSRMLS_CC);
        }
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_DIM_UNSET_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_UNSET TSRMLS_CC);
-       zval *dim = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       zval **container;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_UNSET(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       /* Not needed in DIM_UNSET
-       if (opline->extended_value & ZEND_FETCH_ADD_LOCK) {
-               PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
-       }
-       */
        if (IS_CV == IS_CV) {
                if (container != &EG(uninitialized_zval_ptr)) {
                        SEPARATE_ZVAL_IF_NOT_REF(container);
                }
        }
-       if (IS_CV == IS_VAR && !container) {
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_fetch_dimension_address(&EX_T(opline->result.var), container, dim, IS_CV, BP_VAR_UNSET TSRMLS_CC);
+       zend_fetch_dimension_address(&EX_T(opline->result.var), container, _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC), IS_CV, BP_VAR_UNSET TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
-       if (EX_T(opline->result.var).var.ptr_ptr == NULL) {
+       if (UNEXPECTED(EX_T(opline->result.var).var.ptr_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot unset string offsets");
        } else {
                zend_free_op free_res;
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
 
-               PZVAL_UNLOCK(*EX_T(opline->result.var).var.ptr_ptr, &free_res);
-               if (EX_T(opline->result.var).var.ptr_ptr != &EG(uninitialized_zval_ptr)) {
-                       SEPARATE_ZVAL_IF_NOT_REF(EX_T(opline->result.var).var.ptr_ptr);
+               PZVAL_UNLOCK(*retval_ptr, &free_res);
+               if (retval_ptr != &EG(uninitialized_zval_ptr)) {
+                       SEPARATE_ZVAL_IF_NOT_REF(retval_ptr);
                }
-               PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
+               PZVAL_LOCK(*retval_ptr);
                FREE_OP_VAR_PTR(free_res);
+               CHECK_EXCEPTION();
+               ZEND_VM_NEXT_OPCODE();
        }
-       ZEND_VM_NEXT_OPCODE();
 }
 
-static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_CV_CV(int type, ZEND_OPCODE_HANDLER_ARGS)
+static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_CV_CV(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *container = _get_zval_ptr_cv(opline->op1.var, type TSRMLS_CC);
+       zval *container;
 
-       zval *offset  = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       zval *offset;
 
-       if (Z_TYPE_P(container) != IS_OBJECT || !Z_OBJ_HT_P(container)->read_property) {
-               if (type != BP_VAR_IS) {
-                       zend_error(E_NOTICE, "Trying to get property of non-object");
-               }
+       SAVE_OPLINE();
+       container = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+       offset  = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               zend_error(E_NOTICE, "Trying to get property of non-object");
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
 
        } else {
@@ -29681,7 +31779,7 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_CV_CV(int
                }
 
                /* here we are sure we are dealing with an object */
-               retval = Z_OBJ_HT_P(container)->read_property(container, offset, type, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_R, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
 
                if (!RETURN_VALUE_USED(opline)) {
                        if (Z_REFCOUNT_P(retval) == 0) {
@@ -29690,8 +31788,8 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_CV_CV(int
                                FREE_ZVAL(retval);
                        }
                } else {
-                       AI_SET_PTR(EX_T(opline->result.var).var, retval);
                        PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                }
 
                if (0) {
@@ -29701,21 +31799,25 @@ static int ZEND_FASTCALL zend_fetch_property_address_read_helper_SPEC_CV_CV(int
                }
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_R_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_property_address_read_helper_SPEC_CV_CV(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       return zend_fetch_property_address_read_helper_SPEC_CV_CV(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *property = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       zval *property;
        zval **container;
 
+       SAVE_OPLINE();
+       property = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+
        if (IS_CV == IS_VAR && (opline->extended_value & ZEND_FETCH_ADD_LOCK)) {
                PZVAL_LOCK(*EX_T(opline->op1.var).var.ptr_ptr);
                EX_T(opline->op1.var).var.ptr = *EX_T(opline->op1.var).var.ptr_ptr;
@@ -29724,46 +31826,49 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_W_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLE
        if (0) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
-       if (IS_CV == IS_VAR && !container) {
+       container = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
+
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
        if (0) {
                zval_ptr_dtor(&property);
        } else {
 
        }
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
        /* We are going to assign the result by reference */
        if (opline->extended_value & ZEND_FETCH_MAKE_REF) {
-               Z_DELREF_PP(EX_T(opline->result.var).var.ptr_ptr);
-               SEPARATE_ZVAL_TO_MAKE_IS_REF(EX_T(opline->result.var).var.ptr_ptr);
-               Z_ADDREF_PP(EX_T(opline->result.var).var.ptr_ptr);
+               zval **retval_ptr = EX_T(opline->result.var).var.ptr_ptr;
+
+               Z_DELREF_PP(retval_ptr);
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(retval_ptr);
+               Z_ADDREF_PP(retval_ptr);
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1;
-       zval *property = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_RW TSRMLS_CC);
+       zval *property;
+       zval **container;
+
+       SAVE_OPLINE();
+       property = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+       container = _get_zval_ptr_ptr_cv_BP_VAR_RW(EX_CVs(), opline->op1.var TSRMLS_CC);
 
        if (0) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       if (IS_CV == IS_VAR && !container) {
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_RW TSRMLS_CC);
@@ -29772,37 +31877,83 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_RW_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDL
        } else {
 
        }
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_IS_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       return zend_fetch_property_address_read_helper_SPEC_CV_CV(BP_VAR_IS, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+       USE_OPLINE
+
+       zval *container;
+
+       zval *offset;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_cv_BP_VAR_IS(EX_CVs(), opline->op1.var TSRMLS_CC);
+       offset  = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+
+       if (UNEXPECTED(Z_TYPE_P(container) != IS_OBJECT) ||
+           UNEXPECTED(Z_OBJ_HT_P(container)->read_property == NULL)) {
+               if (RETURN_VALUE_USED(opline)) {
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+               }
+
+       } else {
+               zval *retval;
+
+               if (0) {
+                       MAKE_REAL_ZVAL_PTR(offset);
+               }
+
+               /* here we are sure we are dealing with an object */
+               retval = Z_OBJ_HT_P(container)->read_property(container, offset, BP_VAR_IS, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+
+               if (!RETURN_VALUE_USED(opline)) {
+                       if (Z_REFCOUNT_P(retval) == 0) {
+                               GC_REMOVE_ZVAL_FROM_BUFFER(retval);
+                               zval_dtor(retval);
+                               FREE_ZVAL(retval);
+                       }
+               } else {
+                       PZVAL_LOCK(retval);
+                       AI_SET_PTR(&EX_T(opline->result.var), retval);
+               }
+
+               if (0) {
+                       zval_ptr_dtor(&offset);
+               } else {
+
+               }
+       }
+
+       CHECK_EXCEPTION();
+       ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        if (ARG_SHOULD_BE_SENT_BY_REF(EX(fbc), (opline->extended_value & ZEND_FETCH_ARG_MASK))) {
                /* Behave like FETCH_OBJ_W */
                zend_free_op free_op1;
-               zval *property = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-               zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+               zval *property;
+               zval **container;
+
+               SAVE_OPLINE();
+               property = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+               container = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
 
                if (0) {
                        MAKE_REAL_ZVAL_PTR(property);
                }
-               if (IS_CV == IS_VAR && !container) {
+               if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                        zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
                }
                zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_W TSRMLS_CC);
@@ -29811,27 +31962,27 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_FUNC_ARG_SPEC_CV_CV_HANDLER(ZEND_OPCODE
                } else {
 
                }
-               if (IS_CV == IS_VAR && 0 &&
-                   READY_TO_DESTROY(free_op1.var)) {
-                       AI_USE_PTR(EX_T(opline->result.var).var);
-                       if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                           Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                               SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-                       }
+               if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+                       EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
                }
 
+               CHECK_EXCEPTION();
                ZEND_VM_NEXT_OPCODE();
        } else {
-               return zend_fetch_property_address_read_helper_SPEC_CV_CV(BP_VAR_R, ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
+               return zend_fetch_property_address_read_helper_SPEC_CV_CV(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        }
 }
 
 static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op1, free_res;
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
-       zval *property = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       zval **container;
+       zval *property;
+
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+       property = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
 
        if (IS_CV == IS_CV) {
                if (container != &EG(uninitialized_zval_ptr)) {
@@ -29841,7 +31992,7 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HA
        if (0) {
                MAKE_REAL_ZVAL_PTR(property);
        }
-       if (IS_CV == IS_VAR && !container) {
+       if (IS_CV == IS_VAR && UNEXPECTED(container == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an object");
        }
        zend_fetch_property_address(&EX_T(opline->result.var), container, property, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL), BP_VAR_UNSET TSRMLS_CC);
@@ -29850,13 +32001,8 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HA
        } else {
 
        }
-       if (IS_CV == IS_VAR && 0 &&
-           READY_TO_DESTROY(free_op1.var)) {
-               AI_USE_PTR(EX_T(opline->result.var).var);
-               if (!PZVAL_IS_REF(*EX_T(opline->result.var).var.ptr_ptr) &&
-                   Z_REFCOUNT_PP(EX_T(opline->result.var).var.ptr_ptr) > 2) {
-                       SEPARATE_ZVAL(EX_T(opline->result.var).var.ptr_ptr);
-               }
+       if (IS_CV == IS_VAR && 0 && READY_TO_DESTROY(free_op1.var)) {
+               EXTRACT_ZVAL_PTR(&EX_T(opline->result.var));
        }
 
        PZVAL_UNLOCK(*EX_T(opline->result.var).var.ptr_ptr, &free_res);
@@ -29865,24 +32011,28 @@ static int ZEND_FASTCALL  ZEND_FETCH_OBJ_UNSET_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HA
        }
        PZVAL_LOCK(*EX_T(opline->result.var).var.ptr_ptr);
        FREE_OP_VAR_PTR(free_res);
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
+
+       zval **object_ptr;
+       zval *property_name;
 
-       zval **object_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
-       zval *property_name = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+       property_name = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
 
        if (0) {
                MAKE_REAL_ZVAL_PTR(property_name);
        }
-       if (IS_CV == IS_VAR && !object_ptr) {
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
-       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, op_data->op1_type, &op_data->op1, EX(Ts), ZEND_ASSIGN_OBJ, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+       zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), ZEND_ASSIGN_OBJ, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
        if (0) {
                zval_ptr_dtor(&property_name);
        } else {
@@ -29890,28 +32040,31 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER
        }
 
        /* assign_obj has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
-       zend_op *op_data = opline+1;
+       USE_OPLINE
 
-       zval **object_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       zval **object_ptr;
 
-       if (IS_CV == IS_VAR && !object_ptr) {
+       SAVE_OPLINE();
+       object_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+
+       if (IS_CV == IS_VAR && UNEXPECTED(object_ptr == NULL)) {
                zend_error_noreturn(E_ERROR, "Cannot use string offset as an array");
        }
        if (Z_TYPE_PP(object_ptr) == IS_OBJECT) {
 
-               zval *property_name = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+               zval *property_name = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
 
                if (0) {
                        MAKE_REAL_ZVAL_PTR(property_name);
                }
-               zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, op_data->op1_type, &op_data->op1, EX(Ts), ZEND_ASSIGN_DIM, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
+               zend_assign_to_object(RETURN_VALUE_USED(opline)?&EX_T(opline->result.var).var.ptr:NULL, object_ptr, property_name, (opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), ZEND_ASSIGN_DIM, ((IS_CV == IS_CONST) ? opline->op2.literal : NULL) TSRMLS_CC);
                if (0) {
                        zval_ptr_dtor(&property_name);
                } else {
@@ -29920,30 +32073,44 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER
        } else {
                zend_free_op free_op_data1, free_op_data2;
                zval *value;
-               zval *dim = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+               zval *dim = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
                zval **variable_ptr_ptr;
 
-               zend_fetch_dimension_address(&EX_T(op_data->op2.var), object_ptr, dim, IS_CV, BP_VAR_W TSRMLS_CC);
+               zend_fetch_dimension_address(&EX_T((opline+1)->op2.var), object_ptr, dim, IS_CV, BP_VAR_W TSRMLS_CC);
 
-               value = get_zval_ptr(op_data->op1_type, &op_data->op1, EX(Ts), &free_op_data1, BP_VAR_R);
-               variable_ptr_ptr = _get_zval_ptr_ptr_var(op_data->op2.var, EX(Ts), &free_op_data2 TSRMLS_CC);
-               if (!variable_ptr_ptr) {
-                       if (zend_assign_to_string_offset(&EX_T(op_data->op2.var), value, op_data->op1_type TSRMLS_CC)) {
+               value = get_zval_ptr((opline+1)->op1_type, &(opline+1)->op1, EX_Ts(), &free_op_data1, BP_VAR_R);
+               variable_ptr_ptr = _get_zval_ptr_ptr_var((opline+1)->op2.var, EX_Ts(), &free_op_data2 TSRMLS_CC);
+               if (UNEXPECTED(variable_ptr_ptr == NULL)) {
+                       if (zend_assign_to_string_offset(&EX_T((opline+1)->op2.var), value, (opline+1)->op1_type TSRMLS_CC)) {
                                if (RETURN_VALUE_USED(opline)) {
-                                       EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-                                       ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                                       INIT_PZVAL(EX_T(opline->result.var).var.ptr);
-                                       ZVAL_STRINGL(EX_T(opline->result.var).var.ptr, Z_STRVAL_P(EX_T(op_data->op2.var).str_offset.str)+EX_T(op_data->op2.var).str_offset.offset, 1, 1);
+                                       zval *retval;
+
+                                       ALLOC_ZVAL(retval);
+                                       ZVAL_STRINGL(retval, Z_STRVAL_P(EX_T((opline+1)->op2.var).str_offset.str)+EX_T((opline+1)->op2.var).str_offset.offset, 1, 1);
+                                       INIT_PZVAL(retval);
+                                       AI_SET_PTR(&EX_T(opline->result.var), retval);
                                }
                        } else if (RETURN_VALUE_USED(opline)) {
-                               AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                               PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+                       }
+               } else if (UNEXPECTED(*variable_ptr_ptr == &EG(error_zval))) {
+                       if (IS_TMP_FREE(free_op_data1)) {
+                               zval_dtor(value);
+                       }
+                       if (RETURN_VALUE_USED(opline)) {
+                               PZVAL_LOCK(&EG(uninitialized_zval));
+                               AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                        }
                } else {
-                       value = zend_assign_to_variable(variable_ptr_ptr, value, IS_TMP_FREE(free_op_data1) TSRMLS_CC);
+                       if (IS_TMP_FREE(free_op_data1)) {
+                               value = zend_assign_tmp_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+                       } else {
+                               value = zend_assign_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+                       }
                        if (RETURN_VALUE_USED(opline)) {
-                               AI_SET_PTR(EX_T(opline->result.var).var, value);
                                PZVAL_LOCK(value);
+                               AI_SET_PTR(&EX_T(opline->result.var), value);
                        }
                }
                FREE_OP_VAR_PTR(free_op_data2);
@@ -29951,48 +32118,71 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_DIM_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER
        }
 
        /* assign_dim has two opcodes! */
+       CHECK_EXCEPTION();
        ZEND_VM_INC_OPCODE();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       zval *value;
+       zval **variable_ptr_ptr;
 
-       zval *value = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-       zval **variable_ptr_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+       SAVE_OPLINE();
+       value = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+       variable_ptr_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       if (IS_CV == IS_VAR && !variable_ptr_ptr) {
+       if (IS_CV == IS_VAR && UNEXPECTED(variable_ptr_ptr == NULL)) {
                if (zend_assign_to_string_offset(&EX_T(opline->op1.var), value, IS_CV TSRMLS_CC)) {
                        if (RETURN_VALUE_USED(opline)) {
-                               EX_T(opline->result.var).var.ptr_ptr = &EX_T(opline->result.var).var.ptr;
-                               ALLOC_ZVAL(EX_T(opline->result.var).var.ptr);
-                               INIT_PZVAL(EX_T(opline->result.var).var.ptr);
-                               ZVAL_STRINGL(EX_T(opline->result.var).var.ptr, Z_STRVAL_P(EX_T(opline->op1.var).str_offset.str)+EX_T(opline->op1.var).str_offset.offset, 1, 1);
+                               zval *retval;
+
+                               ALLOC_ZVAL(retval);
+                               ZVAL_STRINGL(retval, Z_STRVAL_P(EX_T(opline->op1.var).str_offset.str)+EX_T(opline->op1.var).str_offset.offset, 1, 1);
+                               INIT_PZVAL(retval);
+                               AI_SET_PTR(&EX_T(opline->result.var), retval);
                        }
                } else if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, EG(uninitialized_zval_ptr));
-                       PZVAL_LOCK(EG(uninitialized_zval_ptr));
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
+               }
+       } else if (IS_CV == IS_VAR && UNEXPECTED(*variable_ptr_ptr == &EG(error_zval))) {
+               if (0) {
+                       zval_dtor(value);
+               }
+               if (RETURN_VALUE_USED(opline)) {
+                       PZVAL_LOCK(&EG(uninitialized_zval));
+                       AI_SET_PTR(&EX_T(opline->result.var), &EG(uninitialized_zval));
                }
        } else {
-               value = zend_assign_to_variable(variable_ptr_ptr, value, 0 TSRMLS_CC);
+               if (0) {
+                       value = zend_assign_tmp_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+               } else {
+                       value = zend_assign_to_variable(variable_ptr_ptr, value TSRMLS_CC);
+               }
                if (RETURN_VALUE_USED(opline)) {
-                       AI_SET_PTR(EX_T(opline->result.var).var, value);
                        PZVAL_LOCK(value);
+                       AI_SET_PTR(&EX_T(opline->result.var), value);
                }
        }
 
        /* zend_assign_to_variable() always takes care of op2, never free it! */
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ASSIGN_REF_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zend_free_op free_op2;
        zval **variable_ptr_ptr;
-       zval **value_ptr_ptr = _get_zval_ptr_ptr_cv(opline->op2.var, BP_VAR_W TSRMLS_CC);
+       zval **value_ptr_ptr;
+
+       SAVE_OPLINE();
+       value_ptr_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op2.var TSRMLS_CC);
 
        if (IS_CV == IS_VAR &&
            value_ptr_ptr &&
@@ -30005,19 +32195,19 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_REF_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER
                zend_error(E_STRICT, "Only variables should be assigned by reference");
                if (UNEXPECTED(EG(exception) != NULL)) {
 
-                       ZEND_VM_NEXT_OPCODE();
+                       HANDLE_EXCEPTION();
                }
                return ZEND_ASSIGN_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);
        } else if (IS_CV == IS_VAR && opline->extended_value == ZEND_RETURNS_NEW) {
                PZVAL_LOCK(*value_ptr_ptr);
        }
-       if (IS_CV == IS_VAR && EX_T(opline->op1.var).var.ptr_ptr == &EX_T(opline->op1.var).var.ptr) {
+       if (IS_CV == IS_VAR && UNEXPECTED(EX_T(opline->op1.var).var.ptr_ptr == &EX_T(opline->op1.var).var.ptr)) {
                zend_error_noreturn(E_ERROR, "Cannot assign by reference to overloaded object");
        }
 
-       variable_ptr_ptr = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
-       if ((IS_CV == IS_VAR && !value_ptr_ptr) ||
-           (IS_CV == IS_VAR && !variable_ptr_ptr)) {
+       variable_ptr_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
+       if ((IS_CV == IS_VAR && UNEXPECTED(value_ptr_ptr == NULL)) ||
+           (IS_CV == IS_VAR && UNEXPECTED(variable_ptr_ptr == NULL))) {
                zend_error_noreturn(E_ERROR, "Cannot create references to/from string offsets nor overloaded objects");
        }
        zend_assign_to_variable_reference(variable_ptr_ptr, value_ptr_ptr TSRMLS_CC);
@@ -30027,43 +32217,47 @@ static int ZEND_FASTCALL  ZEND_ASSIGN_REF_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER
        }
 
        if (RETURN_VALUE_USED(opline)) {
-               AI_SET_PTR(EX_T(opline->result.var).var, *variable_ptr_ptr);
                PZVAL_LOCK(*variable_ptr_ptr);
+               AI_SET_PTR(&EX_T(opline->result.var), *variable_ptr_ptr);
        }
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        zval *function_name;
        char *function_name_strval;
        int function_name_strlen;
 
 
+       SAVE_OPLINE();
        zend_ptr_stack_3_push(&EG(arg_types_stack), EX(fbc), EX(object), EX(called_scope));
 
-       function_name = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       function_name = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
 
-       if (Z_TYPE_P(function_name)!=IS_STRING) {
+       if (IS_CV != IS_CONST &&
+           UNEXPECTED(Z_TYPE_P(function_name) != IS_STRING)) {
                zend_error_noreturn(E_ERROR, "Method name must be a string");
        }
 
        function_name_strval = Z_STRVAL_P(function_name);
        function_name_strlen = Z_STRLEN_P(function_name);
 
-       EX(object) = _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
+       EX(object) = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       if (EX(object) && Z_TYPE_P(EX(object)) == IS_OBJECT) {
-               if (Z_OBJ_HT_P(EX(object))->get_method == NULL) {
+       if (EXPECTED(EX(object) != NULL) &&
+           EXPECTED(Z_TYPE_P(EX(object)) == IS_OBJECT)) {
+               if (UNEXPECTED(Z_OBJ_HT_P(EX(object))->get_method == NULL)) {
                        zend_error_noreturn(E_ERROR, "Object does not support method calls");
                }
 
                /* First, locate the function. */
                EX(fbc) = Z_OBJ_HT_P(EX(object))->get_method(&EX(object), function_name_strval, function_name_strlen, ((IS_CV == IS_CONST) ? (opline->op2.literal + 1) : NULL) TSRMLS_CC);
-               if (!EX(fbc)) {
+               if (UNEXPECTED(EX(fbc) == NULL)) {
                        zend_error_noreturn(E_ERROR, "Call to undefined method %s::%s()", Z_OBJ_CLASS_NAME_P(EX(object)), function_name_strval);
                }
 
@@ -30087,15 +32281,17 @@ static int ZEND_FASTCALL  ZEND_INIT_METHOD_CALL_SPEC_CV_CV_HANDLER(ZEND_OPCODE_H
        }
 
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_CASE_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
        int switch_expr_is_overloaded=0;
 
 
+       SAVE_OPLINE();
        if (IS_CV==IS_VAR) {
                if (EX_T(opline->op1.var).var.ptr_ptr) {
                        PZVAL_LOCK(EX_T(opline->op1.var).var.ptr);
@@ -30105,8 +32301,8 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
                }
        }
        is_equal_function(&EX_T(opline->result.var).tmp_var,
-                                _get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC),
-                                _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC) TSRMLS_CC);
+                                _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC),
+                                _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC) TSRMLS_CC);
 
        if (switch_expr_is_overloaded) {
                /* We only free op1 if this is a string offset,
@@ -30118,47 +32314,32 @@ static int ZEND_FASTCALL  ZEND_CASE_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
                EX_T(opline->op1.var).var.ptr_ptr = NULL;
                EX_T(opline->op1.var).var.ptr = NULL;
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval *array_ptr = &EX_T(opline->result.var).tmp_var;
        zval *expr_ptr;
-       zval *offset=_get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
-       ulong hval;
-       long index;
 
-#if 0 || IS_CV == IS_VAR || IS_CV == IS_CV
-       zval **expr_ptr_ptr = NULL;
+       SAVE_OPLINE();
+       if ((IS_CV == IS_VAR || IS_CV == IS_CV) && opline->extended_value) {
+               zval **expr_ptr_ptr = _get_zval_ptr_ptr_cv_BP_VAR_W(EX_CVs(), opline->op1.var TSRMLS_CC);
 
-       if (opline->extended_value) {
-               expr_ptr_ptr=_get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_W TSRMLS_CC);
+               SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
                expr_ptr = *expr_ptr_ptr;
+               Z_ADDREF_P(expr_ptr);
        } else {
-               expr_ptr=_get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
-       }
-#else
-       expr_ptr=_get_zval_ptr_cv(opline->op1.var, BP_VAR_R TSRMLS_CC);
-#endif
-
-       if (0) { /* temporary variable */
-               zval *new_expr;
+               expr_ptr=_get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op1.var TSRMLS_CC);
+               if (0) { /* temporary variable */
+                       zval *new_expr;
 
-               ALLOC_ZVAL(new_expr);
-               INIT_PZVAL_COPY(new_expr, expr_ptr);
-               expr_ptr = new_expr;
-       } else {
-#if 0 || IS_CV == IS_VAR || IS_CV == IS_CV
-               if (opline->extended_value) {
-                       SEPARATE_ZVAL_TO_MAKE_IS_REF(expr_ptr_ptr);
-                       expr_ptr = *expr_ptr_ptr;
-                       Z_ADDREF_P(expr_ptr);
-               } else
-#endif
-               if (IS_CV == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
+                       ALLOC_ZVAL(new_expr);
+                       INIT_PZVAL_COPY(new_expr, expr_ptr);
+                       expr_ptr = new_expr;
+               } else if (IS_CV == IS_CONST || PZVAL_IS_REF(expr_ptr)) {
                        zval *new_expr;
 
                        ALLOC_ZVAL(new_expr);
@@ -30169,7 +32350,13 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CV_HANDLER(ZEND_OPCODE_
                        Z_ADDREF_P(expr_ptr);
                }
        }
-       if (offset) {
+
+       if (IS_CV != IS_UNUSED) {
+
+               zval *offset = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+               ulong hval;
+               long index;
+
                switch (Z_TYPE_P(offset)) {
                        case IS_DOUBLE:
                                index = zend_dval_to_lval(Z_DVAL_P(offset));
@@ -30178,7 +32365,7 @@ static int ZEND_FASTCALL  ZEND_ADD_ARRAY_ELEMENT_SPEC_CV_CV_HANDLER(ZEND_OPCODE_
                        case IS_BOOL:
                                index = Z_LVAL_P(offset);
 num_index:
-                               zend_hash_index_update(Z_ARRVAL_P(array_ptr), index, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_index_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), index, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_STRING:
                                if (IS_CV == IS_CONST) {
@@ -30191,10 +32378,10 @@ num_index:
                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                        }
                                }
-                               zend_hash_quick_update(Z_ARRVAL_P(array_ptr), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_quick_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval, &expr_ptr, sizeof(zval *), NULL);
                                break;
                        case IS_NULL:
-                               zend_hash_update(Z_ARRVAL_P(array_ptr), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
+                               zend_hash_update(Z_ARRVAL(EX_T(opline->result.var).tmp_var), "", sizeof(""), &expr_ptr, sizeof(zval *), NULL);
                                break;
                        default:
                                zend_error(E_WARNING, "Illegal offset type");
@@ -30204,19 +32391,20 @@ num_index:
                }
 
        } else {
-               zend_hash_next_index_insert(Z_ARRVAL_P(array_ptr), &expr_ptr, sizeof(zval *), NULL);
+               zend_hash_next_index_insert(Z_ARRVAL(EX_T(opline->result.var).tmp_var), &expr_ptr, sizeof(zval *), NULL);
        }
-       if (opline->extended_value) {
+       if ((IS_CV == IS_VAR || IS_CV == IS_CV) && opline->extended_value) {
 
        } else {
 
        }
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
        array_init(&EX_T(opline->result.var).tmp_var);
        if (IS_CV == IS_UNUSED) {
@@ -30230,13 +32418,17 @@ static int ZEND_FASTCALL  ZEND_INIT_ARRAY_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER
 
 static int ZEND_FASTCALL  ZEND_UNSET_DIM_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_UNSET TSRMLS_CC);
-       zval *offset = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       zval **container;
+       zval *offset;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_UNSET(EX_CVs(), opline->op1.var TSRMLS_CC);
+       offset = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
+
        if (IS_CV != IS_VAR || container) {
                if (IS_CV == IS_CV && container != &EG(uninitialized_zval_ptr)) {
                        SEPARATE_ZVAL_IF_NOT_REF(container);
@@ -30270,24 +32462,10 @@ num_index_dim:
                                                                hval = zend_hash_func(Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1);
                                                        }
                                                }
-                                               if (zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval) == SUCCESS &&
-                                           ht == &EG(symbol_table)) {
-                                                       zend_execute_data *ex;
-
-                                                       for (ex = execute_data; ex; ex = ex->prev_execute_data) {
-                                                               if (ex->op_array && ex->symbol_table == ht) {
-                                                                       int i;
-
-                                                                       for (i = 0; i < ex->op_array->last_var; i++) {
-                                                                               if (ex->op_array->vars[i].hash_value == hval &&
-                                                                                   ex->op_array->vars[i].name_len == offset->value.str.len &&
-                                                                                   !memcmp(ex->op_array->vars[i].name, offset->value.str.val, offset->value.str.len)) {
-                                                                                       ex->CVs[i] = NULL;
-                                                                                       break;
-                                                                               }
-                                                                       }
-                                                               }
-                                                       }
+                                               if (ht == &EG(symbol_table)) {
+                                                       zend_delete_global_variable_ex(offset->value.str.val, offset->value.str.len, hval TSRMLS_CC);
+                                               } else {
+                                                       zend_hash_quick_del(ht, Z_STRVAL_P(offset), Z_STRLEN_P(offset)+1, hval);
                                                }
                                                if (IS_CV == IS_CV || IS_CV == IS_VAR) {
                                                        zval_ptr_dtor(&offset);
@@ -30304,7 +32482,7 @@ num_index_dim:
                                break;
                        }
                        case IS_OBJECT:
-                               if (!Z_OBJ_HT_P(*container)->unset_dimension) {
+                               if (UNEXPECTED(Z_OBJ_HT_P(*container)->unset_dimension == NULL)) {
                                        zend_error_noreturn(E_ERROR, "Cannot use object as array");
                                }
                                if (0) {
@@ -30328,15 +32506,20 @@ num_index_dim:
 
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
+
+       zval **container;
+       zval *offset;
 
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_UNSET TSRMLS_CC);
-       zval *offset = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_UNSET(EX_CVs(), opline->op1.var TSRMLS_CC);
+       offset = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
 
        if (IS_CV != IS_VAR || container) {
                if (IS_CV == IS_CV && container != &EG(uninitialized_zval_ptr)) {
@@ -30363,22 +32546,26 @@ static int ZEND_FASTCALL  ZEND_UNSET_OBJ_SPEC_CV_CV_HANDLER(ZEND_OPCODE_HANDLER_
 
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
 static int ZEND_FASTCALL zend_isset_isempty_dim_prop_obj_handler_SPEC_CV_CV(int prop_dim, ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_op *opline = EX(opline);
+       USE_OPLINE
 
-       zval **container = _get_zval_ptr_ptr_cv(opline->op1.var, BP_VAR_IS TSRMLS_CC);
+       zval **container;
        zval **value = NULL;
        int result = 0;
        ulong hval;
        long index;
 
+       SAVE_OPLINE();
+       container = _get_zval_ptr_ptr_cv_BP_VAR_IS(EX_CVs(), opline->op1.var TSRMLS_CC);
+
        if (IS_CV != IS_VAR || container) {
 
-               zval *offset = _get_zval_ptr_cv(opline->op2.var, BP_VAR_R TSRMLS_CC);
+               zval *offset = _get_zval_ptr_cv_BP_VAR_R(EX_CVs(), opline->op2.var TSRMLS_CC);
 
                if (Z_TYPE_PP(container) == IS_ARRAY && !prop_dim) {
                        HashTable *ht;
@@ -30469,7 +32656,7 @@ num_index_prop:
                        zval tmp;
 
                        if (Z_TYPE_P(offset) != IS_LONG) {
-                               tmp = *offset;
+                               ZVAL_COPY_VALUE(&tmp, offset);
                                zval_copy_ctor(&tmp);
                                convert_to_long(&tmp);
                                offset = &tmp;
@@ -30492,13 +32679,13 @@ num_index_prop:
        }
 
        Z_TYPE(EX_T(opline->result.var).tmp_var) = IS_BOOL;
-
        if (opline->extended_value & ZEND_ISSET) {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = result;
-       } else /* if (opline->extended_value & ZEND_ISEMPTY) */ {
+       } else {
                Z_LVAL(EX_T(opline->result.var).tmp_var) = !result;
        }
 
+       CHECK_EXCEPTION();
        ZEND_VM_NEXT_OPCODE();
 }
 
@@ -30514,7 +32701,7 @@ static int ZEND_FASTCALL  ZEND_ISSET_ISEMPTY_PROP_OBJ_SPEC_CV_CV_HANDLER(ZEND_OP
 
 static int ZEND_FASTCALL ZEND_NULL_HANDLER(ZEND_OPCODE_HANDLER_ARGS)
 {
-       zend_error_noreturn(E_ERROR, "Invalid opcode %d/%d/%d.", EX(opline)->opcode, EX(opline)->op1_type, EX(opline)->op2_type);
+       zend_error_noreturn(E_ERROR, "Invalid opcode %d/%d/%d.", OPLINE->opcode, OPLINE->op1_type, OPLINE->op2_type);
 }
 
 
@@ -33200,27 +35387,27 @@ void zend_init_opcodes_handlers(void)
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_CATCH_SPEC_CV_HANDLER,
+       ZEND_CATCH_SPEC_CONST_CV_HANDLER,
+       ZEND_NULL_HANDLER,
+       ZEND_NULL_HANDLER,
+       ZEND_NULL_HANDLER,
+       ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_CATCH_SPEC_CV_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_CATCH_SPEC_CV_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_CATCH_SPEC_CV_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
        ZEND_NULL_HANDLER,
-       ZEND_CATCH_SPEC_CV_HANDLER,
        ZEND_THROW_SPEC_CONST_HANDLER,
        ZEND_THROW_SPEC_CONST_HANDLER,
        ZEND_THROW_SPEC_CONST_HANDLER,
index 18d0e293564d6645f9d756fe51650ec63e02ca53..6f6fed98340cc23f7482f759e7d3f25dc69956ae 100644 (file)
@@ -2,6 +2,7 @@
 
 ZEND_API void {%EXECUTOR_NAME%}(zend_op_array *op_array TSRMLS_DC)
 {
+       DCL_OPLINE
        zend_execute_data *execute_data;
        zend_bool nested = 0;
        zend_bool original_in_execution = EG(in_execution);
@@ -36,29 +37,27 @@ zend_vm_enter:
        EX(nested) = nested;
        nested = 1;
 
-       if (op_array->start_op) {
-               ZEND_VM_SET_OPCODE(op_array->start_op);
-       } else {
-               ZEND_VM_SET_OPCODE(op_array->opcodes);
-       }
+       LOAD_REGS();
 
        if (op_array->this_var != -1 && EG(This)) {
                Z_ADDREF_P(EG(This)); /* For $this pointer */
                if (!EG(active_symbol_table)) {
-                       EX(CVs)[op_array->this_var] = (zval**)EX(CVs) + (op_array->last_var + op_array->this_var);
-                       *EX(CVs)[op_array->this_var] = EG(This);
+                       EX_CV(op_array->this_var) = (zval**)EX_CVs() + (op_array->last_var + op_array->this_var);
+                       *EX_CV(op_array->this_var) = EG(This);
                } else {
-                       if (zend_hash_add(EG(active_symbol_table), "this", sizeof("this"), &EG(This), sizeof(zval *), (void**)&EX(CVs)[op_array->this_var])==FAILURE) {
+                       if (zend_hash_add(EG(active_symbol_table), "this", sizeof("this"), &EG(This), sizeof(zval *), (void**)&EX_CV(op_array->this_var))==FAILURE) {
                                Z_DELREF_P(EG(This));
                        }
                }
        }
 
+       EX(opline) = op_array->start_op ? op_array->start_op : op_array->opcodes;
        EG(opline_ptr) = &EX(opline);
+       LOAD_OPLINE();
 
        EX(function_state).function = (zend_function *) op_array;
        EX(function_state).arguments = NULL;
-       
+
        while (1) {
     {%ZEND_VM_CONTINUE_LABEL%}
 #ifdef ZEND_WIN32
index 0f0c9e6acea64af4a1c448ff1c9e5cfe242f7d88..602e1c12eb88a85ea606bd5d6356031d561144fc 100644 (file)
@@ -118,75 +118,75 @@ $op2_free = array(
 );
 
 $op1_get_zval_ptr = array(
-       "ANY"    => "get_zval_ptr(opline->op1_type, &opline->op1, EX(Ts), &free_op1, \\1)",
-       "TMP"    => "_get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC)",
-       "VAR"    => "_get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC)",
+       "ANY"    => "get_zval_ptr(opline->op1_type, &opline->op1, EX_Ts(), &free_op1, \\1)",
+       "TMP"    => "_get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC)",
+       "VAR"    => "_get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC)",
        "CONST"  => "opline->op1.zv",
        "UNUSED" => "NULL",
-       "CV"     => "_get_zval_ptr_cv(opline->op1.var, \\1 TSRMLS_CC)",
+       "CV"     => "_get_zval_ptr_cv_\\1(EX_CVs(), opline->op1.var TSRMLS_CC)",
 );
 
 $op2_get_zval_ptr = array(
-       "ANY"    => "get_zval_ptr(opline->op2_type, &opline->op2, EX(Ts), &free_op2, \\1)",
-       "TMP"    => "_get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC)",
-       "VAR"    => "_get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC)",
+       "ANY"    => "get_zval_ptr(opline->op2_type, &opline->op2, EX_Ts(), &free_op2, \\1)",
+       "TMP"    => "_get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC)",
+       "VAR"    => "_get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC)",
        "CONST"  => "opline->op2.zv",
        "UNUSED" => "NULL",
-       "CV"     => "_get_zval_ptr_cv(opline->op2.var, \\1 TSRMLS_CC)",
+       "CV"     => "_get_zval_ptr_cv_\\1(EX_CVs(), opline->op2.var TSRMLS_CC)",
 );
 
 $op1_get_zval_ptr_ptr = array(
-       "ANY"    => "get_zval_ptr_ptr(opline->op1_type, &opline->op1, EX(Ts), &free_op1, \\1)",
+       "ANY"    => "get_zval_ptr_ptr(opline->op1_type, &opline->op1, EX_Ts(), &free_op1, \\1)",
        "TMP"    => "NULL",
-       "VAR"    => "_get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC)",
+       "VAR"    => "_get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC)",
        "CONST"  => "NULL",
        "UNUSED" => "NULL",
-       "CV"     => "_get_zval_ptr_ptr_cv(opline->op1.var, \\1 TSRMLS_CC)",
+       "CV"     => "_get_zval_ptr_ptr_cv_\\1(EX_CVs(), opline->op1.var TSRMLS_CC)",
 );
 
 $op2_get_zval_ptr_ptr = array(
-       "ANY"    => "get_zval_ptr_ptr(opline->op2_type, &opline->op2, EX(Ts), &free_op2, \\1)",
+       "ANY"    => "get_zval_ptr_ptr(opline->op2_type, &opline->op2, EX_Ts(), &free_op2, \\1)",
        "TMP"    => "NULL",
-       "VAR"    => "_get_zval_ptr_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC)",
+       "VAR"    => "_get_zval_ptr_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC)",
        "CONST"  => "NULL",
        "UNUSED" => "NULL",
-       "CV"     => "_get_zval_ptr_ptr_cv(opline->op2.var, \\1 TSRMLS_CC)",
+       "CV"     => "_get_zval_ptr_ptr_cv_\\1(EX_CVs(), opline->op2.var TSRMLS_CC)",
 );
 
 $op1_get_obj_zval_ptr = array(
-       "ANY"    => "get_obj_zval_ptr(opline->op1_type, &opline->op1, EX(Ts), &free_op1, \\1)",
-       "TMP"    => "_get_zval_ptr_tmp(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC)",
-       "VAR"    => "_get_zval_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC)",
+       "ANY"    => "get_obj_zval_ptr(opline->op1_type, &opline->op1, EX_Ts(), &free_op1, \\1)",
+       "TMP"    => "_get_zval_ptr_tmp(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC)",
+       "VAR"    => "_get_zval_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC)",
        "CONST"  => "opline->op1.zv",
        "UNUSED" => "_get_obj_zval_ptr_unused(TSRMLS_C)",
-       "CV"     => "_get_zval_ptr_cv(opline->op1.var, \\1 TSRMLS_CC)",
+       "CV"     => "_get_zval_ptr_cv_\\1(EX_CVs(), opline->op1.var TSRMLS_CC)",
 );
 
 $op2_get_obj_zval_ptr = array(
-       "ANY"    => "get_obj_zval_ptr(opline->op2_type, &opline->op2, EX(Ts), &free_op2, \\1)",
-       "TMP"    => "_get_zval_ptr_tmp(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC)",
-       "VAR"    => "_get_zval_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC)",
+       "ANY"    => "get_obj_zval_ptr(opline->op2_type, &opline->op2, EX_Ts(), &free_op2, \\1)",
+       "TMP"    => "_get_zval_ptr_tmp(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC)",
+       "VAR"    => "_get_zval_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC)",
        "CONST"  => "opline->op2.zv",
        "UNUSED" => "_get_obj_zval_ptr_unused(TSRMLS_C)",
-       "CV"     => "_get_zval_ptr_cv(opline->op2.var, \\1 TSRMLS_CC)",
+       "CV"     => "_get_zval_ptr_cv_\\1(EX_CVs(), opline->op2.var TSRMLS_CC)",
 );
 
 $op1_get_obj_zval_ptr_ptr = array(
-       "ANY"    => "get_obj_zval_ptr_ptr(opline->op1_type, &opline->op1, EX(Ts), &free_op1, \\1)",
+       "ANY"    => "get_obj_zval_ptr_ptr(opline->op1_type, &opline->op1, EX_Ts(), &free_op1, \\1)",
        "TMP"    => "NULL",
-       "VAR"    => "_get_zval_ptr_ptr_var(opline->op1.var, EX(Ts), &free_op1 TSRMLS_CC)",
+       "VAR"    => "_get_zval_ptr_ptr_var(opline->op1.var, EX_Ts(), &free_op1 TSRMLS_CC)",
        "CONST"  => "NULL",
        "UNUSED" => "_get_obj_zval_ptr_ptr_unused(TSRMLS_C)",
-       "CV"     => "_get_zval_ptr_ptr_cv(opline->op1.var, \\1 TSRMLS_CC)",
+       "CV"     => "_get_zval_ptr_ptr_cv_\\1(EX_CVs(), opline->op1.var TSRMLS_CC)",
 );
 
 $op2_get_obj_zval_ptr_ptr = array(
-       "ANY"    => "get_obj_zval_ptr_ptr(opline->op2_type, &opline->op2, EX(Ts), &free_op2, \\1)",
+       "ANY"    => "get_obj_zval_ptr_ptr(opline->op2_type, &opline->op2, EX_Ts(), &free_op2, \\1)",
        "TMP"    => "NULL",
-       "VAR"    => "_get_zval_ptr_ptr_var(opline->op2.var, EX(Ts), &free_op2 TSRMLS_CC)",
+       "VAR"    => "_get_zval_ptr_ptr_var(opline->op2.var, EX_Ts(), &free_op2 TSRMLS_CC)",
        "CONST"  => "NULL",
        "UNUSED" => "_get_obj_zval_ptr_ptr_unused(TSRMLS_C)",
-       "CV"     => "_get_zval_ptr_ptr_cv(opline->op2.var, \\1 TSRMLS_CC)",
+       "CV"     => "_get_zval_ptr_ptr_cv_\\1(EX_CVs(), opline->op2.var TSRMLS_CC)",
 );
 
 $op1_is_tmp_free = array(
@@ -504,7 +504,7 @@ function gen_handler($f, $spec, $kind, $name, $op1, $op2, $use, $code, $lineno)
                        }
                        break;
                case ZEND_VM_KIND_GOTO:
-                       out($f,$name.($spec?"_SPEC":"").$prefix[$op1].$prefix[$op2]."_HANDLER:\n");
+                       out($f,$name.($spec?"_SPEC":"").$prefix[$op1].$prefix[$op2]."_HANDLER: ZEND_VM_GUARD(".$name.($spec?"_SPEC":"").$prefix[$op1].$prefix[$op2].");\n");
                        break;
        }
 
@@ -694,7 +694,7 @@ function gen_null_handler($f) {
                $done = 1;
                out($f,"static int ZEND_FASTCALL ZEND_NULL_HANDLER(ZEND_OPCODE_HANDLER_ARGS)\n");
                out($f,"{\n");
-               out($f,"\tzend_error_noreturn(E_ERROR, \"Invalid opcode %d/%d/%d.\", EX(opline)->opcode, EX(opline)->op1_type, EX(opline)->op2_type);\n");
+               out($f,"\tzend_error_noreturn(E_ERROR, \"Invalid opcode %d/%d/%d.\", OPLINE->opcode, OPLINE->op1_type, OPLINE->op2_type);\n");
                out($f,"}\n\n");
        }
 }
@@ -768,11 +768,11 @@ function gen_executor_code($f, $spec, $kind, $prolog) {
                        break;
                case ZEND_VM_KIND_SWITCH:
                        out($f,"default:\n");
-                       out($f,"\tzend_error_noreturn(E_ERROR, \"Invalid opcode %d/%d/%d.\", EX(opline)->opcode, EX(opline)->op1_type, EX(opline)->op2_type);\n");
+                       out($f,"\tzend_error_noreturn(E_ERROR, \"Invalid opcode %d/%d/%d.\", OPLINE->opcode, OPLINE->op1_type, OPLINE->op2_type);\n");
                        break;
                case ZEND_VM_KIND_GOTO:
                        out($f,"ZEND_NULL_HANDLER:\n");
-                       out($f,"\tzend_error_noreturn(E_ERROR, \"Invalid opcode %d/%d/%d.\", EX(opline)->opcode, EX(opline)->op1_type, EX(opline)->op2_type);\n");
+                       out($f,"\tzend_error_noreturn(E_ERROR, \"Invalid opcode %d/%d/%d.\", OPLINE->opcode, OPLINE->op1_type, OPLINE->op2_type);\n");
                        break;
        }
 }
@@ -800,18 +800,60 @@ function gen_executor($f, $skl, $spec, $kind, $executor_name, $initializer_name,
                                        out($f,"static opcode_handler_t zend_vm_get_opcode_handler(zend_uchar opcode, zend_op* op);\n\n");
                                        switch ($kind) {
                                                case ZEND_VM_KIND_CALL:
-                                                       out($f,"\n");
-                                                       out($f,"#define ZEND_VM_CONTINUE()   return 0\n");
-                                                       out($f,"#define ZEND_VM_RETURN()     return 1\n");
-                                                       out($f,"#define ZEND_VM_ENTER()      return 2\n");
-                                                       out($f,"#define ZEND_VM_LEAVE()      return 3\n");
+                                                       out($f,"\n");                                                           
+                                                       out($f,"#undef OPLINE\n");
+                                                       out($f,"#undef DCL_OPLINE\n");
+                                                       out($f,"#undef USE_OPLINE\n");
+                                                       out($f,"#undef LOAD_OPLINE\n");
+                                                       out($f,"#undef SAVE_OPLINE\n");
+                                                       out($f,"#define OPLINE EX(opline)\n");
+                                                       out($f,"#define DCL_OPLINE\n");
+                                                       out($f,"#define USE_OPLINE zend_op *opline = EX(opline);\n");
+                                                       out($f,"#define LOAD_OPLINE()\n");
+                                                       out($f,"#define SAVE_OPLINE()\n");
+                                                       out($f,"#undef CHECK_EXCEPTION\n");
+                                                       out($f,"#undef HANDLE_EXCEPTION\n");
+                                                       out($f,"#undef HANDLE_EXCEPTION_LEAVE\n");
+                                                       out($f,"#define CHECK_EXCEPTION() LOAD_OPLINE()\n");
+                                                       out($f,"#define HANDLE_EXCEPTION() LOAD_OPLINE(); ZEND_VM_CONTINUE()\n");
+                                                       out($f,"#define HANDLE_EXCEPTION_LEAVE() LOAD_OPLINE(); ZEND_VM_LEAVE()\n");
+                                                       out($f,"#define LOAD_REGS()\n");
+                                                       out($f,"#define ZEND_VM_CONTINUE()         return 0\n");
+                                                       out($f,"#define ZEND_VM_RETURN()           return 1\n");
+                                                       out($f,"#define ZEND_VM_ENTER()            return 2\n");
+                                                       out($f,"#define ZEND_VM_LEAVE()            return 3\n");
                                                        out($f,"#define ZEND_VM_DISPATCH(opcode, opline) return zend_vm_get_opcode_handler(opcode, opline)(ZEND_OPCODE_HANDLER_ARGS_PASSTHRU);\n\n");
                                                        out($f,"#define ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_INTERNAL execute_data TSRMLS_CC\n");
                                                        out($f,"#undef EX\n");
                                                        out($f,"#define EX(element) execute_data->element\n\n");
+                                                       out($f,"#undef EX_CV\n");
+                                                       out($f,"#define EX_CV(var) EX(CVs)[var]\n");
+                                                       out($f,"#undef EX_CVs\n");
+                                                       out($f,"#define EX_CVs() EX(CVs)\n");
+                                                       out($f,"#undef EX_T\n");
+                                                       out($f,"#define EX_T(offset) (*(temp_variable *)((char *) EX(Ts) + offset))\n");
+                                                       out($f,"#undef EX_Ts\n");
+                                                       out($f,"#define EX_Ts() EX(Ts)\n\n");
                                                        break;
                                                case ZEND_VM_KIND_SWITCH:
                                                        out($f,"\n");
+                                                       out($f,"#undef OPLINE\n");
+                                                       out($f,"#undef DCL_OPLINE\n");
+                                                       out($f,"#undef USE_OPLINE\n");
+                                                       out($f,"#undef LOAD_OPLINE\n");
+                                                       out($f,"#undef SAVE_OPLINE\n");
+                                                       out($f,"#define OPLINE opline\n");
+                                                       out($f,"#define DCL_OPLINE zend_op *opline;\n");
+                                                       out($f,"#define USE_OPLINE\n");
+                                                       out($f,"#define LOAD_OPLINE() opline = EX(opline)\n");
+                                                       out($f,"#define SAVE_OPLINE() EX(opline) = opline\n");
+                                                       out($f,"#undef CHECK_EXCEPTION\n");
+                                                       out($f,"#undef HANDLE_EXCEPTION\n");
+                                                       out($f,"#undef HANDLE_EXCEPTION_LEAVE\n");
+                                                       out($f,"#define CHECK_EXCEPTION() LOAD_OPLINE()\n");
+                                                       out($f,"#define HANDLE_EXCEPTION() LOAD_OPLINE(); ZEND_VM_CONTINUE()\n");
+                                                       out($f,"#define HANDLE_EXCEPTION_LEAVE() LOAD_OPLINE(); ZEND_VM_LEAVE()\n");
+                                                       out($f,"#define LOAD_REGS()                do {Ts = EX(Ts); CVs = EX(CVs);} while (0)\n");
                                                        out($f,"#define ZEND_VM_CONTINUE() goto zend_vm_continue\n");
                                                        out($f,"#define ZEND_VM_RETURN()   EG(in_execution) = original_in_execution; return\n");
                                                        out($f,"#define ZEND_VM_ENTER()    op_array = EG(active_op_array); goto zend_vm_enter\n");
@@ -820,10 +862,35 @@ function gen_executor($f, $skl, $spec, $kind, $executor_name, $initializer_name,
                                                        out($f,"#define ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_INTERNAL execute_data TSRMLS_CC\n");
                                                        out($f,"#undef EX\n");
                                                        out($f,"#define EX(element) execute_data->element\n\n");
+                                                       out($f,"#undef EX_CV\n");
+                                                       out($f,"#define EX_CV(var) CVs[var]\n");
+                                                       out($f,"#undef EX_CVs\n");
+                                                       out($f,"#define EX_CVs() CVs\n");
+                                                       out($f,"#undef EX_T\n");
+                                                       out($f,"#define EX_T(offset) T(offset)\n");
+                                                       out($f,"#undef EX_Ts\n");
+                                                       out($f,"#define EX_Ts() Ts\n\n");
                                                        break;
                                                case ZEND_VM_KIND_GOTO:
                                                        out($f,"\n");
-                                                       out($f,"#define ZEND_VM_CONTINUE() goto *(void**)(EX(opline)->handler)\n");
+                                                       out($f,"#undef OPLINE\n");
+                                                       out($f,"#undef DCL_OPLINE\n");
+                                                       out($f,"#undef USE_OPLINE\n");
+                                                       out($f,"#undef LOAD_OPLINE\n");
+                                                       out($f,"#undef SAVE_OPLINE\n");
+                                                       out($f,"#define OPLINE opline\n");
+                                                       out($f,"#define DCL_OPLINE zend_op *opline;\n");
+                                                       out($f,"#define USE_OPLINE\n");
+                                                       out($f,"#define LOAD_OPLINE() opline = EX(opline)\n");
+                                                       out($f,"#define SAVE_OPLINE() EX(opline) = opline\n");
+                                                       out($f,"#undef CHECK_EXCEPTION\n");
+                                                       out($f,"#undef HANDLE_EXCEPTION\n");
+                                                       out($f,"#undef HANDLE_EXCEPTION_LEAVE\n");
+                                                       out($f,"#define CHECK_EXCEPTION() if (UNEXPECTED(EG(exception) != NULL)) goto ZEND_HANDLE_EXCEPTION_SPEC_HANDLER\n");
+                                                       out($f,"#define HANDLE_EXCEPTION() goto ZEND_HANDLE_EXCEPTION_SPEC_HANDLER\n");
+                                                       out($f,"#define HANDLE_EXCEPTION_LEAVE() goto ZEND_HANDLE_EXCEPTION_SPEC_HANDLER\n");
+                                                       out($f,"#define LOAD_REGS()                do {Ts = EX(Ts); CVs = EX(CVs);} while (0)\n");
+                                                       out($f,"#define ZEND_VM_CONTINUE() goto *(void**)(OPLINE->handler)\n");
                                                        out($f,"#define ZEND_VM_RETURN()   EG(in_execution) = original_in_execution; return\n");
                                                        out($f,"#define ZEND_VM_ENTER()    op_array = EG(active_op_array); goto zend_vm_enter\n");
                                                        out($f,"#define ZEND_VM_LEAVE()    ZEND_VM_CONTINUE()\n");
@@ -831,6 +898,14 @@ function gen_executor($f, $skl, $spec, $kind, $executor_name, $initializer_name,
                                                        out($f,"#define ZEND_OPCODE_HANDLER_ARGS_PASSTHRU_INTERNAL execute_data TSRMLS_CC\n");
                                                        out($f,"#undef EX\n");
                                                        out($f,"#define EX(element) execute_data->element\n\n");
+                                                       out($f,"#undef EX_CV\n");
+                                                       out($f,"#define EX_CV(var) CVs[var]\n");
+                                                       out($f,"#undef EX_CVs\n");
+                                                       out($f,"#define EX_CVs() CVs\n");
+                                                       out($f,"#undef EX_T\n");
+                                                       out($f,"#define EX_T(offset) T(offset)\n\n");
+                                                       out($f,"#undef EX_Ts\n");
+                                                       out($f,"#define EX_Ts() Ts\n\n");
                                                        break;
                                        }
                                        break;
@@ -839,6 +914,8 @@ function gen_executor($f, $skl, $spec, $kind, $executor_name, $initializer_name,
                                        break;
                                case "HELPER_VARS":
                                        if ($kind != ZEND_VM_KIND_CALL) {
+                                               out($f,$m[1]."temp_variable *Ts;\n");
+                                               out($f,$m[1]."zval ***CVs;\n");
                                                if ($kind == ZEND_VM_KIND_SWITCH) {
                                                        out($f,$m[1]."opcode_handler_t dispatch_handler;\n");
                                                }
@@ -881,13 +958,13 @@ function gen_executor($f, $skl, $spec, $kind, $executor_name, $initializer_name,
                                  // Emit code that dispatches to opcode handler
                                        switch ($kind) {
                                                case ZEND_VM_KIND_CALL:
-                                                       out($f, $m[1]."if ((ret = EX(opline)->handler(execute_data TSRMLS_CC)) > 0)".$m[3]."\n");
+                                                       out($f, $m[1]."if ((ret = OPLINE->handler(execute_data TSRMLS_CC)) > 0)".$m[3]."\n");
                                                        break;
                                                case ZEND_VM_KIND_SWITCH:
-                                                       out($f, $m[1]."dispatch_handler = EX(opline)->handler;\nzend_vm_dispatch:\n".$m[1]."switch ((int)dispatch_handler)".$m[3]."\n");
+                                                       out($f, $m[1]."dispatch_handler = OPLINE->handler;\nzend_vm_dispatch:\n".$m[1]."switch ((int)dispatch_handler)".$m[3]."\n");
                                                        break;
                                                case ZEND_VM_KIND_GOTO:
-                                                       out($f, $m[1]."goto *(void**)(EX(opline)->handler);".$m[3]."\n");
+                                                       out($f, $m[1]."goto *(void**)(OPLINE->handler);".$m[3]."\n");
                                                        break;
                                        }
                                        break;
@@ -1146,6 +1223,12 @@ function gen_vm($def, $skel) {
                out($f,"\n/* Old executor */\n\n");
                out($f,"#undef EX\n");
                out($f,"#define EX(element) execute_data.element\n\n");
+               out($f,"#undef EX_CV\n");
+               out($f,"#define EX_CV(var) EX(CVs)[var]\n");
+               out($f,"#undef EX_CVs\n");
+               out($f,"#define EX_CVs() EX(CVs)\n");
+               out($f,"#undef EX_T\n");
+               out($f,"#define EX_T(offset) (*(temp_variable *)((char *) EX(Ts) + offset))\n\n");
                out($f,"#undef ZEND_VM_CONTINUE\n\n");
                out($f,"#undef ZEND_VM_RETURN\n\n");
                out($f,"#undef ZEND_VM_ENTER\n\n");
@@ -1202,8 +1285,30 @@ function gen_vm($def, $skel) {
        if (count($export) > 0 &&
            !ZEND_VM_OLD_EXECUTOR &&
            ZEND_VM_KIND != ZEND_VM_KIND_CALL) {
+               out($f,"#undef OPLINE\n");
+               out($f,"#undef DCL_OPLINE\n");
+               out($f,"#undef USE_OPLINE\n");
+               out($f,"#undef LOAD_OPLINE\n");
+               out($f,"#undef SAVE_OPLINE\n");
+               out($f,"#define OPLINE EX(opline)\n");
+               out($f,"#define DCL_OPLINE\n");
+               out($f,"#define USE_OPLINE zend_op *opline = EX(opline);\n");
+               out($f,"#define LOAD_OPLINE()\n");
+               out($f,"#define SAVE_OPLINE()\n");
+               out($f,"#undef CHECK_EXCEPTION\n");
+               out($f,"#undef HANDLE_EXCEPTION\n");
+               out($f,"#undef HANDLE_EXCEPTION_LEAVE\n");
+               out($f,"#define CHECK_EXCEPTION() LOAD_OPLINE()\n");
+               out($f,"#define HANDLE_EXCEPTION() LOAD_OPLINE(); ZEND_VM_CONTINUE()\n");
+               out($f,"#define HANDLE_EXCEPTION_LEAVE() LOAD_OPLINE(); ZEND_VM_LEAVE()\n");
                out($f,"#undef EX\n");
                out($f,"#define EX(element) execute_data->element\n\n");
+               out($f,"#undef EX_CV\n");
+               out($f,"#define EX_CV(var) EX(CVs)[var]\n");
+               out($f,"#undef EX_CVs\n");
+               out($f,"#define EX_CVs() EX(CVs)\n");
+               out($f,"#undef EX_T\n");
+               out($f,"#define EX_T(offset) (*(temp_variable *)((char *) EX(Ts) + offset))\n\n");
                out($f,"#undef ZEND_VM_CONTINUE\n");
                out($f,"#undef ZEND_VM_RETURN\n");
                out($f,"#undef ZEND_VM_ENTER\n");
index ebd180556bde4756c21f47e4e2ac596e5473f2e7..baa93983a381f94e19d572d4c84f4503c1b2b589 100644 (file)
@@ -3168,7 +3168,7 @@ PHP_FUNCTION(mb_encode_mimeheader)
        mbfl_string_init(&result);
        ret = mbfl_mime_header_encode(&string, &result, charset, transenc, linefeed, indent);
        if (ret != NULL) {
-               RETVAL_STRINGL((char *)ret->val, ret->len, 0)   /* the string is already strdup()'ed */
+               RETVAL_STRINGL((char *)ret->val, ret->len, 0);  /* the string is already strdup()'ed */
        } else {
                RETVAL_FALSE;
        }
@@ -3192,7 +3192,7 @@ PHP_FUNCTION(mb_decode_mimeheader)
        mbfl_string_init(&result);
        ret = mbfl_mime_header_decode(&string, &result, MBSTRG(current_internal_encoding));
        if (ret != NULL) {
-               RETVAL_STRINGL((char *)ret->val, ret->len, 0)   /* the string is already strdup()'ed */
+               RETVAL_STRINGL((char *)ret->val, ret->len, 0);  /* the string is already strdup()'ed */
        } else {
                RETVAL_FALSE;
        }
index f4ca7e8502c2aac7877182db7504baf609f928db..699d37e79023554da2e83c5130590025bc862f17 100644 (file)
@@ -282,7 +282,7 @@ PHP_FUNCTION(convert_cyr_string)
        str = (unsigned char*) estrndup(input, input_len);
 
        php_convert_cyr_string(str, input_len, fr_cs[0], to_cs[0] TSRMLS_CC);
-       RETVAL_STRING((char *)str, 0)
+       RETVAL_STRING((char *)str, 0);
 }
 /* }}} */