We were checking the value after truncating it to a bitfield.
Thanks to Yunzhong Gao for noticing it.
git-svn-id: https://llvm.org/svn/llvm-project/cfe/trunk@224378
91177308-0d34-0410-b5e6-
96231b3b80d8
ENUM_CODEGENOPT(ObjCDispatchMethod, ObjCDispatchMethodKind, 2, Legacy)
CODEGENOPT(OmitLeafFramePointer , 1, 0) ///< Set when -momit-leaf-frame-pointer is
///< enabled.
-VALUE_CODEGENOPT(OptimizationLevel, 3, 0) ///< The -O[0-4] option specified.
+VALUE_CODEGENOPT(OptimizationLevel, 2, 0) ///< The -O[0-3] option specified.
VALUE_CODEGENOPT(OptimizeSize, 2, 0) ///< If -Os (==1) or -Oz (==2) is specified.
CODEGENOPT(ProfileInstrGenerate , 1, 0) ///< Instrument code to generate
using namespace options;
bool Success = true;
- Opts.OptimizationLevel = getOptimizationLevel(Args, IK, Diags);
+ unsigned OptimizationLevel = getOptimizationLevel(Args, IK, Diags);
// TODO: This could be done in Driver
unsigned MaxOptLevel = 3;
- if (Opts.OptimizationLevel > MaxOptLevel) {
- // If the optimization level is not supported, fall back on the default optimization
+ if (OptimizationLevel > MaxOptLevel) {
+ // If the optimization level is not supported, fall back on the default
+ // optimization
Diags.Report(diag::warn_drv_optimization_value)
<< Args.getLastArg(OPT_O)->getAsString(Args) << "-O" << MaxOptLevel;
- Opts.OptimizationLevel = MaxOptLevel;
+ OptimizationLevel = MaxOptLevel;
}
+ Opts.OptimizationLevel = OptimizationLevel;
// We must always run at least the always inlining pass.
Opts.setInlining(
-// RUN: %clang_cc1 %s -O900 -o /dev/null 2> %t.log
-// RUN: FileCheck %s -input-file=%t.log
+// RUN: %clang_cc1 %s -O900 -o /dev/null 2>&1 | FileCheck %s
-// CHECK: warning: optimization level '-O900' is not supported; using '-O3' instead
+// RUN: %clang_cc1 %s -O8 -o /dev/null 2>&1 | FileCheck %s
+
+// CHECK: warning: optimization level '-O{{.*}}' is not supported; using '-O3' instead